SITE PLAN 1
PROJECT INFORMATION
AND SITE PLAN
1/8"=1'-0"A_0.1NPROJECT ADDRESS:80 LINDA ISLE
LEGAL DESCRIPTION:APN: 050 451 39
OWNER:
PROJECT DESCRIPTION:NEW SINGLE FAMILY RESIDENCE
WITH 4 BEDROOMS, 4.5 BATHROOMS, & 3-CAR GARAGE,
UPGRADED SEAWALL, AND NEW DOCK.
OCCUPANCY:GROUP R-3/U
NUMBER OF STORIES:2
CONSTRUCTION:TYPE V-B
ZONING DISTRICT:R-1 SINGLE UNIT RESIDENTIAL
DESIGN PROFESSIONAL IN
RESPONSIBLE CHARGE:
JR WALZ
510 LARKSPUR AVE,
CORONA DEL MAR, CA 92625
949.836.5977, WALZ.JR@GMAIL.COM
CHRISTIAN FANTICOLA
1422 EDINGER AVE. #150, TUSTIN, CA 92780
949.400.8777
ARCHITECTURAL
A_0.1-3A_1.0
A_1.1
A_1.2
A_2.0-1
A_3.0-1A_4.0-3A_5.0-1A_6.0
LIST OF DRAWINGS
PROJECT DATA
CONTACTS
LOCATION MAP
SITE PLAN / PROJECT INFOFLOOR 1 PLAN
FLOOR 2 PLAN
ROOF PLANEXT. ELEVATIONS
SECTIONS
DETAILS
RCP
DOOR & WINDOW SCHEDULE
HOME OWNERS ASSOC.:LINDA ISLE COMMUNITY
ASSOCIATION
GLAZING NUMBER
WORK POINT
ELEVATION CONTROL
INTERIOR ELEVATION
NORTH ARROW
CENTER LINE
PROPERTY LINE
HIDDEN/CONCEALED LINE
SPOT ELEVATION
DIMENSIONS
GRIDLINES
ELEVATION
BUILDING SECTION
DETAIL/WALL SECTIION
DETAIL ENLARGEMENT
DOOR NUMBER
NEW CONSTRUCTION
1 HOUR CONSTRUCTION
DRAWING SYMBOLS
FANTICOLA.LINDA ISLEABBREVIATIONS
A
@ at
abv. above
AFF Above Finish Floor
A.D. Area Drain
avg. Average
B
Bd. Board
Blw. Below
Bldg. Building
Bm. Beam
BTU British Thermal Unit
C
CFM Cubic Feet per Minute
CIP Cast in place
CMU Concrete masonry Unit
Conc. Concrete
Cont.Continuous
D
Dn Down
DWV Drain/Waste Vent
E
Elasto. Elastomeric
(E)Existing
F
FAU Forced Air Unit
FF Finish Floor
FIN Finish
FJ Floor Joist
FG Finish Grade
FO Face of_
FOP Face of Plywood
FOS Face of Stud
FOF Face of Framing
G
Ga. Guage
Galv. Galvanized
gyp. Gypsum
GSM Galv. Sheet Mtl.
GWB Gypsum Wallboard
H
HVAC Heating, Ventilation and Air
Conditioning Unit
I
Inv. Invert
J
K
L
LPG Liquified Petroleum Gas
M
Mfg. Manufactur(er)
Mtl. Metal
Min. Minimum
N
nic Not In Contract
(N)New
O
o/ Over
OD Outside Diameter
ODU Out Door Unit
OSB Oriented Strand Board
P
Ptd.Painted
PV Plumbing Vent
PW Plywood
R
Req. Required
RJ Roof Joist
RR Roof Rafter
Rm Room
S
S.D. Storm Drain
SF Square Feet
SC Scupper
Stl.Steel
SS Stainless Steel
T
TO Top of_
TOFF Top of Finish Floor
TOR Top of Roof
Typ. Typical
T.G. Top of Grate
TPS Top of Plywood Sheathing
U
UL Underwriters Labratories
UNO Unless Noted Otherwise
V
W
Wd. Wood
w/ With
WH Water Heater
X
Y
CITY OF NB NOTES
1.ISSUANCE OF A BUILDING PERMIT BY THE CITY OF NEWPORT BEACH DOES
NOT RELIEVE APPLICANTS OF THE LEGAL REQUIREMENTS TO OBSERVE
COVENANTS, CONDITIONS AND RESTRICTIONS WHICH MAY BE RECORDED
AGAINST THE PROPERTY OR TO OBTAIN PLANS. YOU SHOULD CONTACT
YOUR COMMUNITY ASSOCIATIONS PRIOR TO COMMENCEMENT OF ANY
CONSTRUCTION AUTHORIZED BY THIS PERMIT.
2.PRIOR TO PERFORMING ANY WORK IN THE CITY RIGHT-OF-WAY AN
ENCROACHMENT PERMIT MUST BE OBTAINED FROM THE PUBLIC WORKS
DEPARTMENT
3.POOLS, SPAS, WALLS, FENCES, PATIO COVERS AND OTHER FREESTANDING
STRUCTURES REQUIRE SEPARATE REVIEWS AND PERMITS
4.A CAL-OSHA PERMIT IS REQUIRED FOR EXCAVATIONS DEEPER THAN 5' AND
FOR SHORING AND UNDERPINNING.
PROPOSED MAX. HEIGHT:23.68' CERIFICATION REQ'D
PARKING:3 COVERED
SCOPE OF WORK AREA CALCS:
LIVING AREA (SF):
-LIVING 1: 2352
-LIVING 2:2847
TOTAL LIVING:5,199
-GARAGE:629
TOTAL AREA:5,828
LANDSCAPE AREA:220
N
1
3
24
80 LINDA ISLE
2-STORY
SINGLE FAMILY
DWELLING
FF: 10.53'
ENERGY
T24.1-2 ENERGY COMPLIANCE
STRUCTURALSN GENERAL NOTESST1-6 TYPICAL DETAILSS1 FOUNDATIONS2FLOOR FRAMING PLANS3ROOF FRAMING PLANSD1-3.0 DETAILS
050 451 39
Scale:JR WALZ
510 LARKSPUR AVENUE
CORONA DEL MAR, CA 92625
949.836.5977
WALZ.JR@GMAIL.COM
WALZ : ARCHITECTURE LLC
Client:Project:Legal Description:Date:THIS DRAWING IS THE PROPERTY OF JR WALZ,
AND IS NOT TO BE REPRODUCED OR COPIED IN
WHOLE OR IN PART WITHOUT PERMISSION. IT IS
NOT TO BE USED ON ANY OTHER PROJECT AND
IS TO BE RETURNED ON REQUEST.
BY
Corrections/Changes:# REVISIONSDATE
Seal/Signature:HOA RECHECK
Issued For:Drawing No:Consultants:Note:Drawing:02.26.2020CHRISTIAN FANTICOLA
FANTICOLA.LINDA ISLE
80 LINDA ISLE
NOTE: SETBACKS ARE MEASURED T0 FACE
OF EXTERIOR FINISH
PROPERTY LINE 124.00'PROPERTY LINE 45.00'PROPERTY LINE 45.00'DN 3R
4'-0"4'-0"25'-0" (E)DRIVEWAY & PAVING TO REMAIN 4'-0"(E)SIDEWALK(E)PLANTER(E)PLANTER(E)PLANTER
CONCRETE SIDE YARD (PER CIVIL)
CONCRETE SIDE YARD (PER CIVIL)
PLANTER
PLANTER
10.90 TW
10.30 FS
10.90 TW GANGWAY (BY OTHERS)10.20 FS
10.90 TW
(E)8.69 FS
12.19 TR3'-0"3'-0"5'-112"
10'-0"
10.90 TW
DOCK (BY OTHERS)LINDA ISLENEWPORT BAY
PATIO (PER CIVIL)
(E)PL WALL TO REMAIN
PROPERTY LINE 124.00'
(E)PL WALL TO REMAIN
(E)METER LOCATIONS TO
REMAIN, UPGRADE PER
UTILITIES
RECESSED ELECTRIC METER LOCATION PER UTILITY
DSDSDSDS
DSDS
REPLACE SEWER LATERAL
& CLEANOUT
88'-412"
712"
10'-212" OPEN
SPACE ABOVE
26'-612"
OPEN SPACE ABOVE & BELOW
36'-7"5'-8"9'-412"712"
35'-3" (MIN. 35' CLEAR)
20'-4" (MIN. 20' CLEAR)10'-2"(MIN. 10' CLEAR)20'-112" (MIN. 20' CLEAR)ENTRYPLANTING PER LANDSCAPE, TYP.
STEPS DOWN TO EXISTING PATIO ELEVATION
3'-0"1'-8"
CLEAR GLASS GUARDRAIL WITH STAINLESS STL.
BASE SHOE SET IN CONCRETE STEM WALL MAX.
42" ABV. (E)PATIO ELEVATION
CONCRETE STEM WALL TO SERVE AS BULKHEAD7'-712"OPEN SPACE37'-0"15%(3293)=494 sfOPEN SPACE REQMT:
OPEN SPACE PROVIDED:511 SF @ ENTRY COURT
OPEN SPACE CALCULATION:
ENERGY CALCULATIONS:MARK MADISON - ENERGY CODE WORKS
2600 MICHELSON DR., STE, 1700
IRVINE, CA 92612
800.700.0131, MARK@ENERGYCODE.COM
STRUCTURAL ENGINEER:
CIVIL ENGINIEERING:ADAM TOAL - TOAL ENGINEERING
139 AVE. NAVARRO, SAN CLEMENTE, 92672
(949) 492-8586
ATOAL@TOALENGINEERING.COM
LANDSCAPE ARCHITECT:
MIKE GABRIEL - STRUCTURAL ENGINEER
483 E. 20TH STREET, COSTA MESA, 92627
949.646.6596, MRGSE@EARTHLINK.COM
SOILS ENGINEER:
RICHARD RAMSEY
3035 BERN LANE, LAGUNA BEACH 92651
949.290.9009
DAN HERC - COAST GEOTECHNICAL
1200 W COMMONWEALTH AVE, FULLERTON,
CA 92833, P: 714.870.1211
COASTGEOTEC@SBCGLOBAL.NET
OUTLINE OF NEIGHBOR HOME
OUTLINE OF NEIGHBOR HOME
LINE OF BUILDING ABOVE
2
A_3.0
1
A_3.0
9.76' FS(E)9.07' FS
9.73' FS
9.84 GF
SLOPE ESTABLISHMENT:
HIGHEST GRADE POINT:10.37'
LOWEST GRADE POINT: 8.69'
POINT DISTANCE:61.67'
SLOPE:1.5%
ALLOWABLE HEIGHT CALCULATION:
GRADE ESTABLISHMENT FOR < 5%:
SUM(9.73 ,9.24, 9.22, 10) / 4: 9.55' AVG.
MAX. ALLOWABLE HEIGHT:+24' (2% ROOF PITCH)=33.55'
PROPOSED HEIGHT:+ 23.75 (CERT.REQ'D)=33.30'
LOT AREA:5,580 SF
BUILDABLE AREA:3,293 SF
MAX. GROSS FLOOR AREA:2 X 3293 = 6,586 SF
CIVILSURVEY TOPOGRAPHIC SURVEYC-1 PRELIM GRADING & DRAINAGE PLANC-2 POLLUTION PREVENTION PLAN
SEAWALL
SW-0 GENERAL NOTES & VICINITY MAPSW-1 SITE PLAN & ELEVATIONSW-2 DETAILS
LANDSCAPEL-1 PLANTING PLAN
2'-512"
OPN
SPC
1'-1112"5'-8" OPENSPACEGENERAL SITE NOTES:
1.EMPLOY NEWPORT BEACH STANDARD EROSION CONTROL MEASURES
THROUGHOUT THE CONSTRUCTION PROCESS.
2.A PUBLIC WORKS DEPARTMENT ENCROACHMENT PERMIT
INSPECTION IS REQUIRED BEFORE THE BUILDING DEPARTMENT
PERMIT FINAL CAN BE ISSUED. AT THE TIME OF PUBLIC WORKS
DEPARTMENT INSPECTION, IF ANY OF THE EXISTING PUBLIC
IMPROVEMENTS SURROUNDING THE SITE IS DAMAGED BY THE
PRIVATE WORK, NEW CONCRETE SIDEWALK, CURB AND GUTTER,
ALLEY/STREET PAVEMENT, AND OTHER PUBLIC IMPROVEMENTS WILL
BE REQUIRED. ADDITIONALLY, IF EXISTING UTILITIES ARE DEEMED
SUBSTANDARD, A NEW 1-INCH WATER SERVICE, WATER METER BOX,
SEWER LATERAL AND/OR CLEANOUT WITH BOX LID WILL BE
REQUIRED. 100% OF THE COST SHALL BE BORNE BY THE PROPERTY
OWNER (MUNICIPAL CODE 14.24.020 AND 14.08.030). SAID
DETERMINATION AND THE EXTENT OF THE REPAIR WORK SHALL BE
MADE AT THE DISCRETION OF THE PUBLIC WORKS INSPECTOR.
3.ALL PRIVATE IRRIGATION SPRINKLER HEADS SHALL BE INSTALLED
AND POSITIONED IN A MANNER THAT WILL NOT CAUSE IRRIGATION
OVERSPRAY ONTO THE PUBLIC RIGHT-OF-WAY.
4.AN APPROVED ENCROACHMENT PERMIT IS REQUIRED FOR ALL WORK
ACTIVITIES WITHIN THE PUBLIC RIGHT-OF-WAY.
5.PROVIDE APPROVED BACKWATER DRAINAGE VALVE FOR FIXTURES
LOCATED BELOW THE ELEVATION OF NEXT UPSTREAM MANHOLE
COVER. FIXTURES ABOVE THIS ELEVATION SHALL NOT DISCHARGE
THROUGH VALVE.
6.PROVIDE 6" HOUSE STREET NUMBER VISIBLE AND LEGIBLE FROM
STREET. NUMBERS SHALL BE OF NON-COMBUSTIBLE MATERIALS IN
SPECIAL FIRE PROTECTION AREAS.
7.AN ENCROACHMENT AGREEMENT IS REQUIRED FOR ALL
NON-STANDARD IMPROVEMENTS WITHIN THE PUBLIC RIGHT-OF-WAY.
ALL NON-STANDARD IMPROVEMENTS SHALL COMPLY WITH CITY
COUNCIL POLICY L-6 AND L-18.
8.ALL STRUCTURES LIMITED TO MAX. +42" WITHIN FRONT SETBACK
AND +72" WITHIN SIDE AND REAR SETBACKS MEASURED FROM
EXISTING GRADE,
9.ALL REQUIRED SETBACK DIMENSIONS ARE FROM FACE OF FINISH
10.ALL WORK RELATED TO WASTEWATER IN THE PUBLIC RIGHT-OF-WAY
SHALL BE PERFORMED BE A C-42 LICENSED SANITATION SEWER
CONTRACTOR OR AN A LICENSED GENERAL ENGINEERING
CONTRACTOR
WATER FEATURE
& ENTRY COURT PER A1.0
PLANTING PER LANDSCAPE
PLANTER PER LANDSCAPE. PROVIDE A CONC. WALL
WITH A 1" AIR GAP BETWEEN THE (E)SITE WALL, TYP.
GENERAL SITE NOTES:
1.EMPLOY NEWPORT BEACH STANDARD EROSION CONTROL MEASURES
THROUGHOUT THE CONSTRUCTION PROCESS.
2.A PUBLIC WORKS DEPARTMENT ENCROACHMENT PERMIT
INSPECTION IS REQUIRED BEFORE THE BUILDING DEPARTMENT
PERMIT FINAL CAN BE ISSUED. AT THE TIME OF PUBLIC WORKS
DEPARTMENT INSPECTION, IF ANY OF THE EXISTING PUBLIC
IMPROVEMENTS SURROUNDING THE SITE IS DAMAGED BY THE
PRIVATE WORK, NEW CONCRETE SIDEWALK, CURB AND GUTTER,
ALLEY/STREET PAVEMENT, AND OTHER PUBLIC IMPROVEMENTS WILL
BE REQUIRED. ADDITIONALLY, IF EXISTING UTILITIES ARE DEEMED
SUBSTANDARD, A NEW 1-INCH WATER SERVICE, WATER METER BOX,
SEWER LATERAL AND/OR CLEANOUT WITH BOX LID WILL BE
REQUIRED. 100% OF THE COST SHALL BE BORNE BY THE PROPERTY
OWNER (MUNICIPAL CODE 14.24.020 AND 14.08.030). SAID
DETERMINATION AND THE EXTENT OF THE REPAIR WORK SHALL BE
MADE AT THE DISCRETION OF THE PUBLIC WORKS INSPECTOR.
3.ALL PRIVATE IRRIGATION SPRINKLER HEADS SHALL BE INSTALLED
AND POSITIONED IN A MANNER THAT WILL NOT CAUSE IRRIGATION
OVERSPRAY ONTO THE PUBLIC RIGHT-OF-WAY.
4.AN APPROVED ENCROACHMENT PERMIT IS REQUIRED FOR ALL WORK
ACTIVITIES WITHIN THE PUBLIC RIGHT-OF-WAY.
5.PROVIDE APPROVED BACKWATER DRAINAGE VALVE FOR FIXTURES
LOCATED BELOW THE ELEVATION OF NEXT UPSTREAM MANHOLE
COVER. FIXTURES ABOVE THIS ELEVATION SHALL NOT DISCHARGE
THROUGH VALVE.
6.PROVIDE 6" HOUSE STREET NUMBER VISIBLE AND LEGIBLE FROM
STREET. NUMBERS SHALL BE OF NON-COMBUSTIBLE MATERIALS IN
SPECIAL FIRE PROTECTION AREAS.
7.AN ENCROACHMENT AGREEMENT IS REQUIRED FOR ALL
NON-STANDARD IMPROVEMENTS WITHIN THE PUBLIC RIGHT-OF-WAY.
ALL NON-STANDARD IMPROVEMENTS SHALL COMPLY WITH CITY
COUNCIL POLICY L-6 AND L-18.
8.ALL STRUCTURES LIMITED TO MAX. +42" WITHIN FRONT SETBACK
AND +72" WITHIN SIDE AND REAR SETBACKS MEASURED FROM
EXISTING GRADE,
9.ALL REQUIRED SETBACK DIMENSIONS ARE FROM FACE OF FINISH
10.ALL WORK RELATED TO WASTEWATER IN THE PUBLIC RIGHT-OF-WAY
SHALL BE PERFORMED BE A C-42 LICENSED SANITATION SEWER
CONTRACTOR OR AN A LICENSED GENERAL ENGINEERING
CONTRACTOR
11.CLEAN OUT MUST NOT BE INSTALLED IN 5'-0" ASSOCIATION
WALKWAY EASEMENT AND 20'-0" ASSOCIATION DRIVEWAY / PARKING
STALL EASEMENT.
12.NO BUILDING ELEMENTS MAY ENCROACH INTO COMMON WALKWAY
EASEMENT, INC. ROOF ELEMENTS
13.REGARDLESS OF CITY OF NEWPORT BEACH DIRECTION, THE
ASSOCIATION WILL NOT ALLOW A FILTRATION SYSTEM OR OTHER
HOMEOWNER PURPOSE IN THE PLANTER AREA ADJACENT TO THE
HOME. IT IS AN EASEMENT IN FAVOR THE ASSOCIATION FOR
LANDSCAPING
14.BUILDING ELEMENTS IN THE FRONT YARD SETBACK (BAY SIDE) SHALL
BE MAX 16" IN HEIGHT.
15.THE ASSOCIATION WILL NOT APPROVE THE USE OF THE 5'-0"
WALKWAY OR 20'-0" DRIVEWAY/GUEST PARKING/PLANTER EASEMENT
FOR HOMEOWNER PURPOSES.
16.CONTRACTOR SHALL SCHEDULE PRE-CONSTRUCTION MEETING WITH
ARCHITECTURAL ADMINISTRATOR TO OBSERVE PRE-CONSTRUCTION
CONDITION OF ASSOCIATION ELEMENTS.
PLANTER PER LANDSCAPE. PROVIDE A CONC. WALL
WITH A 1" AIR GAP BETWEEN THE (E)SITE WALL, TYP.
SITE LEGEND:
·FOOTPRINT OF NEW CONSTRUCTION
DS
·DOWNSPOUT
·FRONT DOOR ENTRY
·PROPERTY LINE
WATER FEATURE EQUIPMENT IN VAULT BELOW
5'-10"31'-2"3'-0"5'-0"UP 4"
UP 4"
HVACHVACwm
GM
SLOPE
PER CIVIL
LEGEND
-2X6 WALL W/ R-21 BATT INSULATION, UNO.
EXTERIOR FINISH PER A2.0-1 EXT. ELEVATIONS
-INTERIOR PLUMBING: WHERE REQ'D FOR ROUTING
PLUMBING PIPES PROVIDE 2X6 CONST.
GENERAL NOTES
·ALL DIMENSIONS ARE TO BE TO THE FACE OF STUD OR CENTERLINE OF THE
COLUMN/PARTITION U.N.O. ALL REQUIRED SETBACK DIMENSIONS ARE TO FACE OF FINISH.
·G.C. TO LAYOUT (IN PAINT) THE LOCATIONS OF ALL PARTITIONS, DOORS, LIGHTING, CEILING
ELEMENTS, SPRINKLERS, SWITCHES, DIMMERS, THERMOSTATS, POWER & COMM.
OUTLETS, MILLWORK AND FURNITURE FOR APPROVAL BY THE OWNER PRIOR TO
CONSTRUCTION.
·IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO BRING TO THE ATTENTION OF THE
ARCHITECT ANY FIELD CONDITIONS THAT DO NOT ALLOW CONSTRUCTION OR
INSTALLATION AS DRAWN.
·DO NOT SCALE DRAWINGS. DIMENSIONS AS INDICATED TAKE PRECEDENT OVER
DRAWINGS.
·PROVIDE CONTINUOUS BACKING FOR REINFORCING OF WALLS TO HANG MILLWORK,
FURNITURE SHELVING OR CABINETRY, WHERE OCCURS.
·PROVIDE MILLWORK SHOP DRAWINGS FOR ARCHITECT'S APPROVAL. MILLWORK TO
COMPLY WITH THE RECOMMENDATIONS OF THE WOODWORK INSTITUTE OF CALIFORNIA
(WIC).
·AT BATHROOM ACCESSORIES, SUCH AS GRAB BARS, TOWEL BARS, SOAP DISHES, ETC. ON
OR WITHIN WALLS SHALL BE SEALED AGAINST MOISTURE AND PROVIDE BACKING AS
REQUIRED.
·AVOID CUT TILES AND BRICK. LAYOUT TO CONSIDER FINAL REQUIREMENT, ADJUST AS
NECESSARY. NOTIFY ARCHITECT OF CHANGES.
PLAN KEY NOTES (SEE INTERIORS FOR APPLIANCE, FIXTURE, AND FINISH SPECS)
1 WATERCLOSET - 1.28 GALLON/FLUSH. PROVIDE 24" CLR. IN FRONT AND 30" CLR.WIDTH. CONCEAL WATER SUPPLY
2
3
5
7
UPPER CABINETS/SHELVES, PER INTERIORS.
RECESSED SOAP SHELF, SLOPE 0.5% TO PREVENT STANDING WATER, REROUTE PLUMB.
4
STAINLESS STEEL SHOWER DRAIN, COORDINATE DRAIN LINE WITH STRUCTURAL
SHOWER OR TUB W/ ANTI-SCALDING THERMOSTATIC MIXING VALVE FIXTURES MAX. 2.0GPM @ 80 PSI. PROVIDE 12" ROUND CLEANOUT. WALL COVERING OF SHOWER SHALLBE TILE, OR APPROVED EQUAL, TO A HEIGHT OF MIN. 72" ABV. DRAIN INLET. FLOAT TILEOVER CEMENT PLASTER BACKING. NET AREA OF SHOWER ENCLOSURE SHALL NOT BELESS THAN 7.1 SQ. FT. OF FLOOR AREA W/ A MIN. 30"Ø CIRCLE. RE: INTERIORS
VANITY & LAVATORY PER INTERIORS, 1.5 GPM @ 80 PSI.
RANGE W/ HOOD VENT MIN. 100 CFM
LINE OF CEILING/OVERHANG ABOVE, TYP.
8
9
10
12
TANKLESS WATER HEATER PER DESIGN/BUILD SUB. AND ENERGY CALCS.VENT TO SIDEYARD
HANDRAIL 34"-38" ABV. LEADING EDGE OF TREAD. HANDRAIL WITH A CIRCULARCROSS-SECTION SHALL HAVE AN OUTSIDE DIAMETER OF AT LEAST 1 1/4 INCHES ANDNOT GREATER THAN 2 INCHES OR SHALL PROVIDE EQUIVALENT GRASPABILITY. IF THEHANDRAIL IS NOT CIRCULAR IT SHALL HAVE A PERIMETER DIMENSION OF AT LEAST 4INCHES AND NOT GREATER THAN 61/4 INCHES WITH A MAXIMUM CROSS-SECTIONDIMENSION OF 2 1/4 INCHES. EDGES SHALL HAVE A MINIMUM RADIUS OF 0.01 INCH PERCBC SECTION 1012.3. HANDRAILS SHALL BE CONT. FOR THE STAIRWAY'S ENTIRELENGTH, UNLESS INTERRUPTED BY A NEWEL POST AND RETURN TO A WALL, GUARD,WALKING SURFACE, OR NEWEL POST. HANDRAILS SHALL HAVE A 1-1/2" CLEAR SPACEBETWEEN THE HANDRAIL AND WALL OR OTHER ADJACENT SURFACE AND SHALL BEFREE OF ANY SHARP OR ABRASIVE ELEMENTS. RE: 3/A4.3
11 HAND/GUARDRAIL 36" ABV. LEADING EDGE OF TREADS, OPENINGS SHALL NOT ALLOWPASSAGE OF A 4-3/8" DIA. SPHERE EXCEPT THE SPACE CREATED BETWEEN THE RISER,TREAD AND BOTTOM RAIL SHALL NOT ALLOW PASSAGE OF A 6" DIA. SPHERE. TOP RAILWILL ACT AS HANDRAIL. HANDRAIL PER NOTE 12 BELOW.
13 POT FILLER PER INTERIOR SPECS
14 STAINLESS STEEL TRENCH DRAIN OUTLET TO PLANTER BELOW
15 MAJESTIC "ECHELON" WDV600 60" DIRECT VENT GAS ONLY FIREPLACE W/ LISTED FLUE
TERMINATION CAPS. INSTALLED TO MEET ALL MANUFACTURER REQUIREMENTS,
TESTED AND CERTIFIED BY CSA TO ANSI Z21.88-2014/CSA 2.33-2014
16 OPEN RISER CANTILEVERED STAIRCASE, MIN. 10" TREAD DEPTH, RISERS PER PLAN
(MAX. 7.75"). MAX 4" OPEN RISER.
17 CUSTOM BUILT-IN MILLWORK PER INTERIORS
18 WASHER & DRYER: WASHER SHALL BE QUALIFIED ENERGY STAR APPLIANCE WITH
MAXIMUM WATER USE FACTOR OF 6 GALLONS PER CUBIC FEET OF DRUM CAPACITY.
(NBMC 15.11.010) CLOTHES DRYER. 4" Ø VENT W/ MAX. (2) 90° BENDS, 14' MAX RUN.
VENT TO DAYLIGHT AT SIDE YARD W/ VENT CAP AND BACK DRAFT DAMPER, TYP.
20
-SEPARATION WALL MIN. 1/2" GWB ON GARAGE
SIDE
-2X4 INTERIOR WALL W/ R-15 BATT UNSULATION.
VERIFY WITH STRUCTURAL.
-DOUBLE STUD WALL PER PLAN DIMENSION
19 FRAMELESS TEMPERED GLASS SHOWER ENCLOSURE
21 GUARDRAIL MIN. 42" AFF - PER DETAILS
22 ELECTRICAL SUB-PANEL, MAINTAIN 36" FROM FACE CLEAR OF ALL OBSTRUCTION
23 COPPER ROOF DRAIN W/ 2" OVERFLOW TO OUTLET VISIBLY INTO SIDEYARD BELOW
24 5" COPPER GUTTER AND 3" SQUARE DOWNSPOUTS, TYP.
25 RECESSED BACKLIT MIRROR
26
27 DISHWASHER, ENERGY STAR CERTIFIED
28 PULL OUT TRASH DRAWER
29 ROOF ACCESS DOOR ABOVE WITH STEEL ACCESS LADDER
30 DARK BRONZE TRENCH DRAIN ASSEMBLY, CONNECT SUBTERRANEAN DRAIN LINES
1
LIGHT COVE ABOVE
6 KITCHEN SINK AND FAUCET PER INTERIORS, 1.8 GPM @ 80 PSI.
31
A/C CONDENSING UNIT. PROVIDE SCREEN TO MATCH METAL SIDING, SOUND
ATTENUATION REPORT UNDER SEPARATE PLAN REVIEW AND PERMIT
32
RECESSED SHOWER PAN33
34 11" THICKENED OPENING
35 RE-CIRCULATING WATER FEATURE BELOW STAIR W/ INTEGRAL LIGHTING, CONCEAL
PUMP
36 36" TALL COUNTERTOP
37 UTILITY SINK PER INTERIORS, 1.5 GPM @ 80 PSI.
38 LINE OF CABINET BELOW
39
40
41 COOKING VENT DUCT CHASE/CHIMNEY
INDICATES EMERGENCY EGRESS W/ MIN. 5.7 SF OPENING (MIN. 20" CLEAR WIDTH X 24"
CLEAR HEIGHT). CRANK MECHANISM FOR OPERABLE WINDOWS SHALL NOT PROJECT
INTO REQD. NET OPENING REQMTS.
2
LANDING: MAX. 5" BELOW THRESHOLD. WHERE DOOR DOES NOTSWING OVER LANDING MAX. 7.75" BELOW THRESHOLD.
COUNTER-DEPTH SIDE BY SIDE REFRIGERATOR/FREEZER
1A WALL HUNG WATERCLOSET PER NOTE 1 FAU, 100 S.I. COMBUSTION AIR PROVIDED THRU LOUVERED DOOR. PROVIDE MIN. 30"CLR. HEIGHT AT SERVICE SIDE. PROVIDE HIGH EFFICACY LIGHT FIXTURE AND SWITCHADJACENT TO DOOR
METER/MAIN LOCATION. KEEP THREE FEET CLEAR FROM FACE OF ELECTRICAL PANEL TO
ANY WALL SURFACE OR OBSTRUCTION.
42 SHADE POCKET ABV.
43 RECESSED HEADBOARD LIGHTING
44 SKYLIGHT ABOVE
FLOOR 1 1
B1
050 451 39
Scale:JR WALZ
510 LARKSPUR AVENUE
CORONA DEL MAR, CA 92625
949.836.5977
WALZ.JR@GMAIL.COM
WALZ : ARCHITECTURE LLC
Client:Project:Legal Description:Date:THIS DRAWING IS THE PROPERTY OF JR WALZ,
AND IS NOT TO BE REPRODUCED OR COPIED IN
WHOLE OR IN PART WITHOUT PERMISSION. IT IS
NOT TO BE USED ON ANY OTHER PROJECT AND
IS TO BE RETURNED ON REQUEST.
BY
Corrections/Changes:# REVISIONSDATE
Seal/Signature:HOA RECHECK
Issued For:Drawing No:Consultants:Note:Drawing:02.26.2020CHRISTIAN FANTICOLA
FANTICOLA.LINDA ISLE
80 LINDA ISLE
PLANS
1/4"=1'-0"A_1.0
PANTRY
113
KITCHEN
112
DINING
111
LIVING
110
GARAGE
109
ENTRY
100
HALL
101
MUD
102
BATH 1
105
UP 18
BAR
107
WATER FEATURE
U/C
WINE
ICE
REF / FRZR
OVEN
TR.WRM.
DRWR DW
REF.
DRWR
POWDER
103
TR
BEDROOM 1
104
MECHCLOSET
CLOSET
106
22'-812"22'-2"26'-712"
4'-3"3'-1"3'-212"11'-10"4'-3"5'-412"26'-0"5'-412"7'-0"15'-412"20'-0"16'-0"8'-112"1'-6"1'-6"
12'-4"13'-5"
4'-912"2'-5"4'-6"2'-5"4'-6"2'-5"18'-1"2'-5"2'-412"11'-0"5'-712"4'-6"4'-512"20'-112"20'-0" CLEAR MIN.6'-712"DRY CLEAN
CLOSET
10'-712"1
A_2.0
2
A_2.0
4
A_2.1
3
A_2.1
DN 3R
PLANTER
PLANTER
1
A_3.1
2
A_3.1
3
A_3.1
4
A_3.1
2
A_3.0
1
A_3.0
1
A_3.0
2
A_3.0 4"12"1'-1012"
3'-212"
6'-10"2'-512"10'-9"3'-712"1'-112"5'-8" OPEN SPACE1'-1112"2'-512"
OPEN
SPACE
1'-11"26'-612" OPEN SPACE2'-1"7'-712" OPEN SPACE10'-0"4'-0"4'-0"25'-0"
12'-10"5'-312"110A
101A
109B
109C
109A
K1
C1 C2 C3 D1
000A 100A
104A105A106A
STAIR
108
103A
103B
102B102A
F1 G1
ENTRY
114
VEST.
000
8 1326436171740
39
17
22
31
5
17
31
1A
10
FLAT
6436 28
27
U/C
WINE
4
36
62836 31
3636
38
38
9
9
55311A193323717
9
9
3439
15 1717311731
OPEN TO ABOVE
1631 9
9
20
20
20
20'-4"
20'-0" CLEAR MIN.
35'-3"
35'-0" CLEAR MIN.
SCREENED TRASH AREA 2'-0"44'-0"50'-0"
7'-012"5'-7"7'-012"
PLANTER
TYP.
ENTRY COURT
(OPEN SPACE
SHOWN HATCHED)
WATER FEATURE: -12"
EQUIPMENT
VAULT BELOW
STONE
STEPPER, TYP.
UP 4"
UP 4"
050 451 39
Scale:JR WALZ
510 LARKSPUR AVENUE
CORONA DEL MAR, CA 92625
949.836.5977
WALZ.JR@GMAIL.COM
WALZ : ARCHITECTURE LLC
Client:Project:Legal Description:Date:THIS DRAWING IS THE PROPERTY OF JR WALZ,
AND IS NOT TO BE REPRODUCED OR COPIED IN
WHOLE OR IN PART WITHOUT PERMISSION. IT IS
NOT TO BE USED ON ANY OTHER PROJECT AND
IS TO BE RETURNED ON REQUEST.
BY
Corrections/Changes:# REVISIONSDATE
Seal/Signature:HOA RECHECK
Issued For:Drawing No:Consultants:Note:Drawing:02.26.2020CHRISTIAN FANTICOLA
FANTICOLA.LINDA ISLE
80 LINDA ISLE
PLANS
1/4"=1'-0"A_1.1
200B
M.SUITE
200
M.BATH
201
GYM
209
BATH 2
205
M.CLOSET
210BATH 3
206
BED 3
207
BED 2
204
SAFE
CLOSET
CLOSET
LIBRARY
FAMILY
208
SITTING
211
OPEN TO BELOW
DN 18R LINEN
STEAM SHOWER
HTD. FLR
HTD. FLR
HTD. FLRLAUNDRY
202
CABINETS
A/V
CHASE
7'-11"15'-6"13'-6"14'-0"16'-8"16'-6"13'-412"13'-412"9'-734"7'-6"10'-112"18'-512"12'-212"
4'-6"3'-112"5'-1012"
17'-11"36'-9"11'-11"11'-1112"5'-0"7'-5"4'-6"7'-034"7'-614"
1
A_3.1
2
A_3.1
3
A_3.1
4
A_3.1
1
A_2.0
2
A_2.0
4
A_2.1
3
A_2.1
4"4"4"2
A_3.0
1
A_3.0
1
A_3.0
2
A_3.0 6'-0" OPEN SPACE2'-512"
OPEN
SPACE
26'-612" OPEN SPACE10'-1" OPEN SPACE
9"8'-0" OPEN SPACE36'-0"1'-0"1'-712"1'-5"712"2'-2"2'-2"11"10'-2"4'-0"
512"
10'-0"4'-0"4'-0"25'-0"
200A
L1L2B3
B2 C4 C5
C6C7
D1
E1
G2 J1
201A
201B
W.C.
210A
HALL/STAIR
203
209A208A
202A
207A
204A
206A
207B
205A
204B87'-934"ROOF/
ACCESS
1541 17 31173131171717
21
42
31
3143312
5
5
25
30
25
19
+18" BENCH
2 33
1
17
9
7 17 9
211611
424293131525
19
33
9
7
2
3
44
17
31 5 25
19
33
9
7
2
3
1
44
1
17
17
17
31
29
31
44 31 44 44
44
1837 17
LEGEND
-2X6 WALL W/ R-21 BATT INSULATION, UNO.
EXTERIOR FINISH PER A2.0-1 EXT. ELEVATIONS
-INTERIOR PLUMBING: WHERE REQ'D FOR ROUTING
PLUMBING PIPES PROVIDE 2X6 CONST.
GENERAL NOTES
·ALL DIMENSIONS ARE TO BE TO THE FACE OF STUD OR CENTERLINE OF THE
COLUMN/PARTITION U.N.O. ALL REQUIRED SETBACK DIMENSIONS ARE TO FACE OF FINISH.
·G.C. TO LAYOUT (IN PAINT) THE LOCATIONS OF ALL PARTITIONS, DOORS, LIGHTING, CEILING
ELEMENTS, SPRINKLERS, SWITCHES, DIMMERS, THERMOSTATS, POWER & COMM.
OUTLETS, MILLWORK AND FURNITURE FOR APPROVAL BY THE OWNER PRIOR TO
CONSTRUCTION.
·IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO BRING TO THE ATTENTION OF THE
ARCHITECT ANY FIELD CONDITIONS THAT DO NOT ALLOW CONSTRUCTION OR
INSTALLATION AS DRAWN.
·DO NOT SCALE DRAWINGS. DIMENSIONS AS INDICATED TAKE PRECEDENT OVER
DRAWINGS.
·PROVIDE CONTINUOUS BACKING FOR REINFORCING OF WALLS TO HANG MILLWORK,
FURNITURE SHELVING OR CABINETRY, WHERE OCCURS.
·PROVIDE MILLWORK SHOP DRAWINGS FOR ARCHITECT'S APPROVAL. MILLWORK TO
COMPLY WITH THE RECOMMENDATIONS OF THE WOODWORK INSTITUTE OF CALIFORNIA
(WIC).
·AT BATHROOM ACCESSORIES, SUCH AS GRAB BARS, TOWEL BARS, SOAP DISHES, ETC. ON
OR WITHIN WALLS SHALL BE SEALED AGAINST MOISTURE AND PROVIDE BACKING AS
REQUIRED.
·AVOID CUT TILES AND BRICK. LAYOUT TO CONSIDER FINAL REQUIREMENT, ADJUST AS
NECESSARY. NOTIFY ARCHITECT OF CHANGES.
PLAN KEY NOTES (SEE INTERIORS FOR APPLIANCE, FIXTURE, AND FINISH SPECS)
1 WATERCLOSET - 1.28 GALLON/FLUSH. PROVIDE 24" CLR. IN FRONT AND 30" CLR.WIDTH. CONCEAL WATER SUPPLY
2
3
5
7
UPPER CABINETS/SHELVES, PER INTERIORS.
RECESSED SOAP SHELF, SLOPE 0.5% TO PREVENT STANDING WATER, REROUTE PLUMB.
4
STAINLESS STEEL SHOWER DRAIN, COORDINATE DRAIN LINE WITH STRUCTURAL
SHOWER OR TUB W/ ANTI-SCALDING THERMOSTATIC MIXING VALVE FIXTURES MAX. 2.0GPM @ 80 PSI. PROVIDE 12" ROUND CLEANOUT. WALL COVERING OF SHOWER SHALLBE TILE, OR APPROVED EQUAL, TO A HEIGHT OF MIN. 72" ABV. DRAIN INLET. FLOAT TILEOVER CEMENT PLASTER BACKING. NET AREA OF SHOWER ENCLOSURE SHALL NOT BELESS THAN 7.1 SQ. FT. OF FLOOR AREA W/ A MIN. 30"Ø CIRCLE. RE: INTERIORS
VANITY & LAVATORY PER INTERIORS, 1.5 GPM @ 80 PSI.
RANGE W/ HOOD VENT MIN. 100 CFM
LINE OF CEILING/OVERHANG ABOVE, TYP.
8
9
10
12
TANKLESS WATER HEATER PER DESIGN/BUILD SUB. AND ENERGY CALCS.VENT TO SIDEYARD
HANDRAIL 34"-38" ABV. LEADING EDGE OF TREAD. HANDRAIL WITH A CIRCULARCROSS-SECTION SHALL HAVE AN OUTSIDE DIAMETER OF AT LEAST 1 1/4 INCHES ANDNOT GREATER THAN 2 INCHES OR SHALL PROVIDE EQUIVALENT GRASPABILITY. IF THEHANDRAIL IS NOT CIRCULAR IT SHALL HAVE A PERIMETER DIMENSION OF AT LEAST 4INCHES AND NOT GREATER THAN 61/4 INCHES WITH A MAXIMUM CROSS-SECTIONDIMENSION OF 2 1/4 INCHES. EDGES SHALL HAVE A MINIMUM RADIUS OF 0.01 INCH PERCBC SECTION 1012.3. HANDRAILS SHALL BE CONT. FOR THE STAIRWAY'S ENTIRELENGTH, UNLESS INTERRUPTED BY A NEWEL POST AND RETURN TO A WALL, GUARD,WALKING SURFACE, OR NEWEL POST. HANDRAILS SHALL HAVE A 1-1/2" CLEAR SPACEBETWEEN THE HANDRAIL AND WALL OR OTHER ADJACENT SURFACE AND SHALL BEFREE OF ANY SHARP OR ABRASIVE ELEMENTS. RE: 3/A4.3
11 HAND/GUARDRAIL 36" ABV. LEADING EDGE OF TREADS, OPENINGS SHALL NOT ALLOWPASSAGE OF A 4-3/8" DIA. SPHERE EXCEPT THE SPACE CREATED BETWEEN THE RISER,TREAD AND BOTTOM RAIL SHALL NOT ALLOW PASSAGE OF A 6" DIA. SPHERE. TOP RAILWILL ACT AS HANDRAIL. HANDRAIL PER NOTE 12 BELOW.
13 POT FILLER PER INTERIOR SPECS
14 STAINLESS STEEL TRENCH DRAIN OUTLET TO PLANTER BELOW
15 MAJESTIC "ECHELON" WDV600 60" DIRECT VENT GAS ONLY FIREPLACE W/ LISTED FLUE
TERMINATION CAPS. INSTALLED TO MEET ALL MANUFACTURER REQUIREMENTS,
TESTED AND CERTIFIED BY CSA TO ANSI Z21.88-2014/CSA 2.33-2014
16 OPEN RISER CANTILEVERED STAIRCASE, MIN. 10" TREAD DEPTH, RISERS PER PLAN
(MAX. 7.75"). MAX 4" OPEN RISER.
17 CUSTOM BUILT-IN MILLWORK PER INTERIORS
18 WASHER & DRYER: WASHER SHALL BE QUALIFIED ENERGY STAR APPLIANCE WITH
MAXIMUM WATER USE FACTOR OF 6 GALLONS PER CUBIC FEET OF DRUM CAPACITY.
(NBMC 15.11.010) CLOTHES DRYER. 4" Ø VENT W/ MAX. (2) 90° BENDS, 14' MAX RUN.
VENT TO DAYLIGHT AT SIDE YARD W/ VENT CAP AND BACK DRAFT DAMPER, TYP.
20
-SEPARATION WALL MIN. 1/2" GWB ON GARAGE
SIDE
-2X4 INTERIOR WALL W/ R-15 BATT UNSULATION.
VERIFY WITH STRUCTURAL.
-DOUBLE STUD WALL PER PLAN DIMENSION
19 FRAMELESS TEMPERED GLASS SHOWER ENCLOSURE
21 GUARDRAIL MIN. 42" AFF - PER DETAILS
22 ELECTRICAL SUB-PANEL, MAINTAIN 36" FROM FACE CLEAR OF ALL OBSTRUCTION
23 COPPER ROOF DRAIN W/ 2" OVERFLOW TO OUTLET VISIBLY INTO SIDEYARD BELOW
24 5" COPPER GUTTER AND 3" SQUARE DOWNSPOUTS, TYP.
25 RECESSED BACKLIT MIRROR
26
27 DISHWASHER, ENERGY STAR CERTIFIED
28 PULL OUT TRASH DRAWER
29 ROOF ACCESS DOOR ABOVE WITH STEEL ACCESS LADDER
30 DARK BRONZE TRENCH DRAIN ASSEMBLY, CONNECT SUBTERRANEAN DRAIN LINES
1
LIGHT COVE ABOVE
6 KITCHEN SINK AND FAUCET PER INTERIORS, 1.8 GPM @ 80 PSI.
31
A/C CONDENSING UNIT. PROVIDE SCREEN TO MATCH METAL SIDING, SOUND
ATTENUATION REPORT UNDER SEPARATE PLAN REVIEW AND PERMIT
32
RECESSED SHOWER PAN33
34 11" THICKENED OPENING
35 RE-CIRCULATING WATER FEATURE BELOW STAIR W/ INTEGRAL LIGHTING, CONCEAL
PUMP
36 36" TALL COUNTERTOP
37 UTILITY SINK PER INTERIORS, 1.5 GPM @ 80 PSI.
38 LINE OF CABINET BELOW
39
40
41 COOKING VENT DUCT CHASE/CHIMNEY
INDICATES EMERGENCY EGRESS W/ MIN. 5.7 SF OPENING (MIN. 20" CLEAR WIDTH X 24"
CLEAR HEIGHT). CRANK MECHANISM FOR OPERABLE WINDOWS SHALL NOT PROJECT
INTO REQD. NET OPENING REQMTS.
2
LANDING: MAX. 5" BELOW THRESHOLD. WHERE DOOR DOES NOTSWING OVER LANDING MAX. 7.75" BELOW THRESHOLD.
COUNTER-DEPTH SIDE BY SIDE REFRIGERATOR/FREEZER
1A WALL HUNG WATERCLOSET PER NOTE 1 FAU, 100 S.I. COMBUSTION AIR PROVIDED THRU LOUVERED DOOR. PROVIDE MIN. 30"CLR. HEIGHT AT SERVICE SIDE. PROVIDE HIGH EFFICACY LIGHT FIXTURE AND SWITCHADJACENT TO DOOR
METER/MAIN LOCATION. KEEP THREE FEET CLEAR FROM FACE OF ELECTRICAL PANEL TO
ANY WALL SURFACE OR OBSTRUCTION.
42 SHADE POCKET ABV.
43 RECESSED HEADBOARD LIGHTING
44 SKYLIGHT ABOVE
FLOOR 2 1
ENTRY COURT
"OPEN SPACE"
SHOWN HATCHED
2'-11"5'-10"
ROOF PLAN 1
PLANS
1/4"=1'-0"A_1.2
ROOF NOTES
1.PROVIDE R-30 FIBERGLASS BATT ATTIC INSULATION, INSURE MIN. 1" SPACE BETWEEN
TOP OF INSULATION AND BOTTOM OF ROOF SHEATHING.
2.PROVIDE R-19 FIBERGLASS BATT FLOOR INSULATION
3.OBTAIN FIRE SPRINKLER PERMIT PRIOR TO CALLING FOR ROOF SHEATHING INSPECTION.
4.VENTILATION OF ENCLOSED SPACES BETWEEN RAFTERS
CITY OF NEWPORT BEACH BUILDING CODE POLICY 1505.3:
UBC SECTION 1505.3 ALLOWS THE BUILDING OFFICIAL DISCRETION TO REQUIRE THAT
ATTIC SPACE OF WOOD CONSTRUCTION AND ENCLOSED RAFTER SPACES FORMED
WHERE THE CEILING IS APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF RAFTERS, BE
VENTILATED TO PREVENT CONDENSATION BUILDUP RESULTING FROM CONDUCIVE
CLIMATIC CONDITIONS.
SINCE THE CITY OF NEWPORT BEACH IS A COASTAL TOWN WITH MODERATE CLIMATE
THROUGHOUT THE YEAR WITH A SMALL TEMPERATURE DIFFERENCE BETWEEN DAY AND
NIGHT; AND SINCE THERE HAS NOT BEEN A HISTORY OF WOOD DECAY DUE TO UNVENTED
CAVITIES BETWEEN RAFTERS; AND SINCE IT IS NOT PRACTICAL TO PROVIDE CROSS
VENTILATION OF THESE CAVITIES DUE TO SHEAR TRANSFER REQUIREMENTS; IT IS THE
POLICY OF THE CITY OF NEWPORT BEACH BUILDING DEPARTMENT NOT TO REQUIRE
VENTILATION OF ENCLOSED SPACES BETWEEN ROOF RAFTERS.2% MIN. TYP.2% MIN. TYP.CLASS 'A' MODIFIED BITUMEN SHEET
ROOFING, CERTAINTEED FLINTASTIC
COOLSTAR PER ICC ESR 1388, TYP. -
LIGHT GRAY MINERAL FINISH
2% MIN. TYP.2% MIN. TYP.RIDGE: 32.93'RIDGE 33.00'RIDGE 33.00'RIDGE: 32.782
%
M
I
N
.
T
Y
P
.2% MIN. TYP.2% MIN. TYP.2% MIN. TYP.2% MIN. TYP.2% MIN. TYP.2%
M
I
N
.
T
Y
P
.2% MIN. TYP.PLASTER PARAPET TO MATCH WALLS, TYP.: 33.28'2% MIN. TYP.
PLASTER PARAPET TO MATCH WALLS, TYP.: 33.28'PLASTER PARAPET TO MATCH WALLS TYP.: 33.28'CLASS 'A' MODIFIED BITUMEN SHEET
ROOFING, CERTAINTEED FLINTASTIC
COOLSTAR PER ICC ESR 1388, TYP. -
LIGHT GRAY MINERAL FINISH
PROPERTY LINE
PROPERTY LINE 4'-0"4'-0"10'-0"
25'-0"
Y1
Y2 Z1
1
A_3.1
2
A_3.1
3
A_3.1
4
A_3.1
1
A_2.0
2
A_2.0
4
A_2.1
3
A_2.1
2
A_3.0
1
A_3.0
1
A_3.0
2
A_3.0
Y3 Y4
A/C CONDENSERS
WITH SCREEN
SCREEN: 36.36'
Y4
23
TYP.
41 15
TYP.
ROOF
ACCESS
HATCH 3'-0"3'-0"PLASTER PARAPET TO MATCH WALLS, TYP.: 33.28'
PLASTER PARAPET TO MATCH WALLS, TYP.: 33.28'
ALUMIMUM PARAPET TO MATCH SIDING
ALUMIMUM PARAPET TO MATCH SIDING
STONE PARAPET AT LOWER ROOF TO MATCH STONE VENEER
050 451 39
Scale:JR WALZ
510 LARKSPUR AVENUE
CORONA DEL MAR, CA 92625
949.836.5977
WALZ.JR@GMAIL.COM
WALZ : ARCHITECTURE LLC
Client:Project:Legal Description:Date:THIS DRAWING IS THE PROPERTY OF JR WALZ,
AND IS NOT TO BE REPRODUCED OR COPIED IN
WHOLE OR IN PART WITHOUT PERMISSION. IT IS
NOT TO BE USED ON ANY OTHER PROJECT AND
IS TO BE RETURNED ON REQUEST.
BY
Corrections/Changes:# REVISIONSDATE
Seal/Signature:HOA RECHECK
Issued For:Drawing No:Consultants:Note:Drawing:02.26.2020CHRISTIAN FANTICOLA
FANTICOLA.LINDA ISLE
80 LINDA ISLE
PLAN KEY NOTES (SEE INTERIORS FOR APPLIANCE, FIXTURE, AND FINISH SPECS)
1 WATERCLOSET - 1.28 GALLON/FLUSH. PROVIDE 24" CLR. IN FRONT AND 30" CLR.WIDTH. CONCEAL WATER SUPPLY
2
3
5
7
UPPER CABINETS/SHELVES, PER INTERIORS.
RECESSED SOAP SHELF, SLOPE 0.5% TO PREVENT STANDING WATER, REROUTE PLUMB.
4
STAINLESS STEEL SHOWER DRAIN, COORDINATE DRAIN LINE WITH STRUCTURAL
SHOWER OR TUB W/ ANTI-SCALDING THERMOSTATIC MIXING VALVE FIXTURES MAX. 2.0GPM @ 80 PSI. PROVIDE 12" ROUND CLEANOUT. WALL COVERING OF SHOWER SHALLBE TILE, OR APPROVED EQUAL, TO A HEIGHT OF MIN. 72" ABV. DRAIN INLET. FLOAT TILEOVER CEMENT PLASTER BACKING. NET AREA OF SHOWER ENCLOSURE SHALL NOT BELESS THAN 7.1 SQ. FT. OF FLOOR AREA W/ A MIN. 30"Ø CIRCLE. RE: INTERIORS
VANITY & LAVATORY PER INTERIORS, 1.5 GPM @ 80 PSI.
RANGE W/ HOOD VENT MIN. 100 CFM
LINE OF CEILING/OVERHANG ABOVE, TYP.
8
9
10
12
TANKLESS WATER HEATER PER DESIGN/BUILD SUB. AND ENERGY CALCS.VENT TO SIDEYARD
HANDRAIL 34"-38" ABV. LEADING EDGE OF TREAD. HANDRAIL WITH A CIRCULARCROSS-SECTION SHALL HAVE AN OUTSIDE DIAMETER OF AT LEAST 1 1/4 INCHES ANDNOT GREATER THAN 2 INCHES OR SHALL PROVIDE EQUIVALENT GRASPABILITY. IF THEHANDRAIL IS NOT CIRCULAR IT SHALL HAVE A PERIMETER DIMENSION OF AT LEAST 4INCHES AND NOT GREATER THAN 61/4 INCHES WITH A MAXIMUM CROSS-SECTIONDIMENSION OF 2 1/4 INCHES. EDGES SHALL HAVE A MINIMUM RADIUS OF 0.01 INCH PERCBC SECTION 1012.3. HANDRAILS SHALL BE CONT. FOR THE STAIRWAY'S ENTIRELENGTH, UNLESS INTERRUPTED BY A NEWEL POST AND RETURN TO A WALL, GUARD,WALKING SURFACE, OR NEWEL POST. HANDRAILS SHALL HAVE A 1-1/2" CLEAR SPACEBETWEEN THE HANDRAIL AND WALL OR OTHER ADJACENT SURFACE AND SHALL BEFREE OF ANY SHARP OR ABRASIVE ELEMENTS. RE: 3/A4.3
11 HAND/GUARDRAIL 36" ABV. LEADING EDGE OF TREADS, OPENINGS SHALL NOT ALLOWPASSAGE OF A 4-3/8" DIA. SPHERE EXCEPT THE SPACE CREATED BETWEEN THE RISER,TREAD AND BOTTOM RAIL SHALL NOT ALLOW PASSAGE OF A 6" DIA. SPHERE. TOP RAILWILL ACT AS HANDRAIL. HANDRAIL PER NOTE 12 BELOW.
13 POT FILLER PER INTERIOR SPECS
14 STAINLESS STEEL TRENCH DRAIN OUTLET TO PLANTER BELOW
15 MAJESTIC "ECHELON" WDV600 60" DIRECT VENT GAS ONLY FIREPLACE W/ LISTED FLUE
TERMINATION CAPS. INSTALLED TO MEET ALL MANUFACTURER REQUIREMENTS,
TESTED AND CERTIFIED BY CSA TO ANSI Z21.88-2014/CSA 2.33-2014
16 OPEN RISER CANTILEVERED STAIRCASE, MIN. 10" TREAD DEPTH, RISERS PER PLAN
(MAX. 7.75"). MAX 4" OPEN RISER.
17 CUSTOM BUILT-IN MILLWORK PER INTERIORS
18 WASHER & DRYER: WASHER SHALL BE QUALIFIED ENERGY STAR APPLIANCE WITH
MAXIMUM WATER USE FACTOR OF 6 GALLONS PER CUBIC FEET OF DRUM CAPACITY.
(NBMC 15.11.010) CLOTHES DRYER. 4" Ø VENT W/ MAX. (2) 90° BENDS, 14' MAX RUN.
VENT TO DAYLIGHT AT SIDE YARD W/ VENT CAP AND BACK DRAFT DAMPER, TYP.
20
19 FRAMELESS TEMPERED GLASS SHOWER ENCLOSURE
21 GUARDRAIL MIN. 42" AFF - PER DETAILS
22 ELECTRICAL SUB-PANEL, MAINTAIN 36" FROM FACE CLEAR OF ALL OBSTRUCTION
23 COPPER ROOF DRAIN W/ 2" OVERFLOW TO OUTLET VISIBLY INTO SIDEYARD BELOW
24 5" COPPER GUTTER AND 3" SQUARE DOWNSPOUTS, TYP.
25 RECESSED BACKLIT MIRROR
26
27 DISHWASHER, ENERGY STAR CERTIFIED
28 PULL OUT TRASH DRAWER
29 ROOF ACCESS DOOR ABOVE WITH STEEL ACCESS LADDER
30 DARK BRONZE TRENCH DRAIN ASSEMBLY, CONNECT SUBTERRANEAN DRAIN LINES
LIGHT COVE ABOVE
6 KITCHEN SINK AND FAUCET PER INTERIORS, 1.8 GPM @ 80 PSI.
31
A/C CONDENSING UNIT. PROVIDE SCREEN TO MATCH METAL SIDING, SOUND
ATTENUATION REPORT UNDER SEPARATE PLAN REVIEW AND PERMIT
32
RECESSED SHOWER PAN33
34 11" THICKENED OPENING
35 RE-CIRCULATING WATER FEATURE BELOW STAIR W/ INTEGRAL LIGHTING, CONCEAL
PUMP
36 36" TALL COUNTERTOP
37 UTILITY SINK PER INTERIORS, 1.5 GPM @ 80 PSI.
38 LINE OF CABINET BELOW
39
40
41 COOKING VENT DUCT CHASE/CHIMNEY
LANDING: MAX. 5" BELOW THRESHOLD. WHERE DOOR DOES NOTSWING OVER LANDING MAX. 7.75" BELOW THRESHOLD.
COUNTER-DEPTH SIDE BY SIDE REFRIGERATOR/FREEZER
1A WALL HUNG WATERCLOSET PER NOTE 1 FAU, 100 S.I. COMBUSTION AIR PROVIDED THRU LOUVERED DOOR. PROVIDE MIN. 30"CLR. HEIGHT AT SERVICE SIDE. PROVIDE HIGH EFFICACY LIGHT FIXTURE AND SWITCHADJACENT TO DOOR
METER/MAIN LOCATION. KEEP THREE FEET CLEAR FROM FACE OF ELECTRICAL PANEL TO
ANY WALL SURFACE OR OBSTRUCTION.
42 SHADE POCKET ABV.
43 RECESSED HEADBOARD LIGHTING
44 SKYLIGHT ABOVE
5'-10"RIDGE: 32.7835.28' T.O.SHROUD
35.28' T.O.SHROUD
4'-0"2'-0"4'-0"2'-0"8'-0"4'-0"RIDGE: 32.93'PROPERTY LINEPROPERTY LINE
PROPERTY LINEPROPERTY LINEPROPERTY LINEEAST (SIDE) ELEVATION
1
ELEVATIONS
1/4"=1'-0"A_2.0
050 451 39
Scale:JR WALZ
510 LARKSPUR AVENUE
CORONA DEL MAR, CA 92625
949.836.5977
WALZ.JR@GMAIL.COM
WALZ : ARCHITECTURE LLC
Client:Project:Legal Description:Date:THIS DRAWING IS THE PROPERTY OF JR WALZ,
AND IS NOT TO BE REPRODUCED OR COPIED IN
WHOLE OR IN PART WITHOUT PERMISSION. IT IS
NOT TO BE USED ON ANY OTHER PROJECT AND
IS TO BE RETURNED ON REQUEST.
BY
Corrections/Changes:# REVISIONSDATE
Seal/Signature:HOA RECHECK
Issued For:Drawing No:Consultants:Note:Drawing:02.26.2020CHRISTIAN FANTICOLA
FANTICOLA.LINDA ISLE
80 LINDA ISLE
NORTH (FRONT) ELEVATION
2
FIN. FLOOR: 10.53' (+0")
ALUMINUM CLAD WINDOWS - DARK
BRONZE FINISH, TYP.
DOVE GRAY INTEGRAL COLOR PLASTER PARAPET
- TO MATCH WALLS
T.O.PLATE(+20'-6")
FIN. FLOOR 2: (+11'-0")
109A
B1
ALUMINUM PANELS WITH FLUSH
SEAMS - DARK BRONZE FINISH
ALUMINUM SHROUD TO MATCH
WALL PANELS
10'-0"
10'-712"
ALUM. CLAD WINDOWS - DARK BRONZE
FINISH - TRANSLUCENT SANDBLASTED GLASS
GARAGE DOORS AND GATES - ALUMINUM PANELS
WITH FLUSH SEAMS - DARK BRONZE FINISH
ALUMINUM PERFORATED PANELS WITH FLUSH
SEAMS - DARK BRONZE FINISH, OVER
BLACKED OUT EXTERIOR PLASTER FINISH
FIN. FLOOR: 10.53' (+0")
DOVE GRAY INTEGRAL COLOR PLASTER PARAPET
- TO MATCH WALLS
T.O.PLATE(+20'-6")
FIN. FLOOR 2: (+11'-0")
12X36X34 LIMESTONE VENEER - BRUSHED & BUSH HAMMERED
T.O.PARAPET 33.28'(+22'-9")
DOVE GRAY INTEGRAL COLOR PLASTER
T.O.PARAPET 33.28'(+22'-9")
4'-0"4'-0"
EST. GRADE: 9.55'
RECESSED SLOT DETAILS - ALUMINUM PANELS WITH
FLUSH SEAMS - DARK BRONZE FINISH, O/ BLACKED
OUT EXT. PLASTER
12X36X34 LIMESTONE VENEER - BRUSHED & BUSH HAMMERED
DOVE GRAY INTEGRAL COLOR PLASTER
DOVE GRAY INTEGRAL COLOR PLASTER
1
A_3.0
2
A_3.0
1
A_3.1
2
A_3.1
3
A_3.1
4
A_3.1
CONCEALED PACKAGE DROPOFF DOOR
TOP OF (E)PROPERTY LINE SITE WALLTOP OF (E)PROPERTY LINE SITE WALLS
TOP OF PLANTER WALLS
TOP OF GUARDRAIL
TOP OF BULKHEAD
T.O.BULKHEAD: 10.65' (+112")
(E)PATIO FS: 8.69'
CONTOUR OF EXISTING SIDEYARD HARDSCAPE
CONTOUR OF EXISTING SIDEYARD HARDSCAPE
A/C UNIT SCREENED ENCLOSURE TO MATCH
PERFORATED ALUM. PANELS - DARK BRONZE ANODIZED
A/C UNIT SCREENED ENCLOSURE TO MATCH
PERFORATED ALUM. PANELS - DARK BRONZE ANODIZED
EST. GRADE: 9.55'23'-9"23'-9"3'-0"3'-0"2'-0"A2 A1
001A
B3
C1C2C3D1
E1
F1G1
C4C5
G2
J1
T.O.SHROUD 35.28'(+24'-9")
T.O.SCREEN 36.28'(+25'-9")
T.O.SCREEN 36.28'(+25'-9")
4'-0"
PROPERTY LINEPROPERTY LINEPROPERTY LINEWEST (SIDE) ELEVATION
3
ELEVATIONS
1/4"=1'-0"A_2.1
050 451 39
Scale:JR WALZ
510 LARKSPUR AVENUE
CORONA DEL MAR, CA 92625
949.836.5977
WALZ.JR@GMAIL.COM
WALZ : ARCHITECTURE LLC
Client:Project:Legal Description:Date:THIS DRAWING IS THE PROPERTY OF JR WALZ,
AND IS NOT TO BE REPRODUCED OR COPIED IN
WHOLE OR IN PART WITHOUT PERMISSION. IT IS
NOT TO BE USED ON ANY OTHER PROJECT AND
IS TO BE RETURNED ON REQUEST.
BY
Corrections/Changes:# REVISIONSDATE
Seal/Signature:HOA RECHECK
Issued For:Drawing No:Consultants:Note:Drawing:02.26.2020CHRISTIAN FANTICOLA
FANTICOLA.LINDA ISLE
80 LINDA ISLE
SOUTH (BACK) ELEVATION
4
ALUMINUM PANELS WITH FLUSH
SEAMS - DARK BRONZE FINISH
FIN. FLOOR: 10.53' (+0")
ALUMINUM PARAPET CAP- DARK BRONZE FINISH
T.O.PLATE(+20'-6")
FIN. FLOOR 2: (+11'-0")
DOVE GRAY INTEGRAL COLOR SMOOTH PLASTER, TYP.
T.O.SHROUD 35.28'(+24'-9")
4'-0"4'-0"
ALBERTINI ALUMINUM SLIDING GLASS DOORS -
DARK BRONZE FINISH, CLEAR GLASS
CLEAR GLASS RAILING W/ DARK BONZE TOP
RAIL
ALUMINUM SHROUD TO MATCH
WALL PANELS, TYP.
ALUMINUM PANELS WITH FLUSH SEAMS -
DARK BRONZE FINISH
FIN. FLOOR: 10.53' (+0")
ALUMINUM PARAPET CAP- BRONZE FINISH
T.O.PLATE(+20'-6")
FIN. FLOOR 2: (+11'-0")
DOVE GRAY INTEGRAL COLOR SMOOTH PLASTER, TYP.
ALUMINUM TRIM WITH FLUSH SEAMS - DARK
BRONZE FINISH
T.O.PARAPET 33.28'(+22'-9")
10'-712"
ALUMINUM CLAD WINDOWS - DARK BRONZE
FINISH, CLEAR GLASS
ALUMINUM SHROUD TO MATCH WALL PANELS, TYP.
10'-0"
12X36X34 LIMESTONE VENEER -
BRUSHED & BUSH HAMMERED
1
A_3.0
2
A_3.0
1
A_3.1
2
A_3.1
3
A_3.1
4
A_3.1
ELECTRICAL PANEL PER A_0.1
TOP OF (E)PROPERTY LINE SITE WALL
TOP OF (E)PROPERTY LINE SITE WALLS
TOP OF PLANTER WALLS
TOP OF GUARDRAIL
T.O.BULKHEAD: 10.65' (+112")
(E)PATIO FS: 8.69'
CONTOUR OF EXISTING SIDEYARD HARDSCAPE
CONTOUR OF EXISTING SIDEYARD HARDSCAPE
T.O.BULKHEAD: 10.65' (+112")
TOP OF (E)PROPERTY LINE SITE WALLS
TOP OF PLANTER WALLS
TOP OF (E)PROPERTY LINE SITE WALL
TOP OF PLANTER WALLS
TOP OF GUARDRAILS IN FOREGROUND
A/C UNIT SCREENED ENCLOSURE TO MATCH
PERFORATED ALUM. PANELS - DARK BRONZE ANODIZED
A/C UNIT SCREENED ENCLOSURE TO MATCH PERFORATED
ALUM. PANELS - DARK BRONZE ANODIZED
EST. GRADE: 9.55'
EST. GRADE: 9.55'23'-9"2'-0"3'-0"3'-0"23'-9"2'-0"K1
L1L2C6C7B2
110A
200B
109B
2'-0"HEIGHT CERTIFICATION REQUIRED
T.O.PARAPET 33.28'(+22'-9")
T.O.SHROUD 35.28'(+24'-9")
T.O.SCREEN 36.28'(+25'-9")
T.O.SCREEN 36.28'(+25'-9")
4'-0"
2'-0"2'-0"
10'-0"
PROPERTY LINEPROPERTY LINELONGITUDINAL SECTION
1
SECTIONS
1/4"=1'-0"A_3.0
050 451 39
Scale:JR WALZ
510 LARKSPUR AVENUE
CORONA DEL MAR, CA 92625
949.836.5977
WALZ.JR@GMAIL.COM
WALZ : ARCHITECTURE LLC
Client:Project:Legal Description:Date:THIS DRAWING IS THE PROPERTY OF JR WALZ,
AND IS NOT TO BE REPRODUCED OR COPIED IN
WHOLE OR IN PART WITHOUT PERMISSION. IT IS
NOT TO BE USED ON ANY OTHER PROJECT AND
IS TO BE RETURNED ON REQUEST.
BY
Corrections/Changes:# REVISIONSDATE
Seal/Signature:HOA RECHECK
Issued For:Drawing No:Consultants:Note:Drawing:02.26.2020CHRISTIAN FANTICOLA
FANTICOLA.LINDA ISLE
80 LINDA ISLE
LONGITUDINAL SECTION
2
CLEAR GLASS RAILING W/ DARK BONZE TOP
RAIL
FIN. FLOOR: 10.53' (+0")
T.O.PLATE(+20'-6")
FIN. FLOOR 2: (+11'-0")
ALUMINUM SLIDING GLASS DOORS - DARK
BRONZE FINISH, CLEAR GLASS
T.O.PARAPET 33.28'(+22'-9")
10'-712"
10'-0"
ALBERTINI ALUMINUM SLIDING GLASS DOORS
- DARK BRONZE FINISH, CLEAR GLASS
CLEAR GLASS RAILING W/ DARK BONZE TOP
RAIL
ALUMINUM SLIDING GLASS DOORS - DARK
BRONZE FINISH, CLEAR GLASS
WALL POCKET FOR SLIDING GLASS DOORS3'-6"3'-6"FIN. FLOOR: 10.53' (+0")
T.O.PLATE(+20'-6")
FIN. FLOOR 2: (+11'-0")
T.O.PARAPET 33.28'(+22'-9")
COVE LIGHT (TYP.) SEE R.C.P.
DINING
111
LIVING
110
ENTRY
100
DINING BEYOND
111
LIVING
110GARAGE
109
HALLBEDROOM 1
104
M.SUITE
200M.BATH
201
LAUNDRY
205
M.SUITE
200
BATH 2
203
BED 2
203 LIBRARY LINENSTAIR
ENTRY BEYOND
100
1
A_3.1
2
A_3.1
3
A_3.1
4
A_3.1
DOCK GANGWAY BY OTHERS
PLANTER BEYOND
CLEAR GLASS RAILING W/ DARK BRONZE TOP RAIL
CONCRETE BULKHEAD
3'-0"1'-1112"1'-612"3'-6"5'-6"
REINFORCED SEAWALL BELOW, BY OTHERS
REINFORCED SEAWALL BELOW, BY OTHERS
T.O.BULKHEAD: 10.65' (+112")
T.O.BULKHEAD: 10.65' (+112")
ALUMINUM PARAPET CAP- BRONZE FINISH
ALUMINUM PARAPET CAP- DARK BRONZE FINISH
1
A_3.1
2
A_3.1
3
A_3.1
4
A_3.1
(E)PATIO FS: 8.98'
1'-8"
EST. GRADE: 9.55'
EST. GRADE: 9.55'
1
A_4.0 OPP.
6
A_4.3 TYP.
3
A_4.0 OPP.2
A_4.0
6
A_4.1
6
A_4.0TYP.
8
A_4.0TYP.
4
A_4.1
9
A_4.2
7
A_4.2
1
A_4.2 OPP.
5
A_4.0 OPP.
11
A_4.0
12
A_4.0
1'-0"3
A_4.3
11
A_4.2
14
A_4.1 OPP.
5
A_4.0
3
A_4.2 OPP.
1
A_4.3 OPP.
3
A_4.0 OPP.
6
A_4.3TYP.
1
A_4.3 OPP.
T.O.PLANTER: 11.65' (+1'-112")
ENTRY COURT
WATER FEATURE
PROPERTY LINEPROPERTY LINEPROPERTY LINEPROPERTY LINEPROPERTY LINEPROPERTY LINEPROPERTY LINEPROPERTY LINE050 451 39
Scale:JR WALZ
510 LARKSPUR AVENUE
CORONA DEL MAR, CA 92625
949.836.5977
WALZ.JR@GMAIL.COM
WALZ : ARCHITECTURE LLC
Client:Project:Legal Description:Date:THIS DRAWING IS THE PROPERTY OF JR WALZ,
AND IS NOT TO BE REPRODUCED OR COPIED IN
WHOLE OR IN PART WITHOUT PERMISSION. IT IS
NOT TO BE USED ON ANY OTHER PROJECT AND
IS TO BE RETURNED ON REQUEST.
BY
Corrections/Changes:# REVISIONSDATE
Seal/Signature:HOA RECHECK
Issued For:Drawing No:Consultants:Note:Drawing:02.26.2020CHRISTIAN FANTICOLA
FANTICOLA.LINDA ISLE
80 LINDA ISLE
CROSS SECTION
CROSS SECTION
2
1
SECTIONS
1/4"=1'-0"A_3.1
FIN. FLOOR: 10.53' (+0")
T.O.PLATE(+20'-6")
FIN. FLOOR 2: (+11'-0")
T.O.PARAPET 33.28'(+22'-9")
FIN. FLOOR: 10.53' (+0")
T.O.PLATE(+20'-6")
FIN. FLOOR 2: (+11'-0")
T.O.PARAPET 33.28'(+22'-9")
ALUMINUM PERFORATED PANELS WITH FLUSH
SEAMS - DARK BRONZE BRONZE FINISH, OVER
BLACKED OUT EXTERIOR PLASTER FINISH
DOVE GRAY INTEGRAL COLOR PLASTER
ALUMINUM FRONT DOOR WITH
CLEAR GLASS - DARK BRONZE FINISH
PERFORATED METAL SCREENED HVAC UNIT, SEE ROOF PLAN
GARAGE
109
CLOSET
GARAGE
109
BEDROOM 1
104
BATH 2
203
BATH 3
203
CLOSET
STUDY
203
CLOSET
HALL
1
A_3.0
2
A_3.0
1
A_3.0
2
A_3.0
DOVE GRAY INTEGRAL COLOR PLASTER PARAPET
- TO MATCH WALLS
DOVE GRAY INTEGRAL COLOR PLASTER PARAPET
- TO MATCH WALLS
CROSS SECTION
CROSS SECTION
4
3
FIN. FLOOR: 10.53' (+0")
T.O.PLATE(+20'-6")
FIN. FLOOR 2: (+11'-0")
T.O.PARAPET 33.28'(+22'-9")
FIN. FLOOR: 10.53' (+0")
T.O.PLATE(+20'-6")
FIN. FLOOR 2: (+11'-0")
T.O.PARAPET 33.28'(+22'-9")
SKYLIGHT WELL FLUSH WITH WALL
COVE LIGHT (TYP.) SEE R.C.P.
LAUNDRY
203
HALL GYM
203
M. SUITE
200
SITTING
205
LIVING
110
KITCHEN
112
PANTRY
113
DINING
111
HALL
101
STAIR
1
A_3.0
2
A_3.0
1
A_3.0
2
A_3.0
DOVE GRAY INTEGRAL COLOR PLASTER PARAPET
- TO MATCH WALLS
EST. GRADE: 9.55'EST. GRADE: 9.55'
EST. GRADE: 9.55'
1
A_4.0 OPP.
5
A_4.0
13
A_4.2
10
A_4.0
-
A_4.0
6
A_4.3
TYP.
TYP.
1
A_4.1TYP.4
A_4.0
7
A_4.1
9
A_4.1
7
A_4.0
2
A_4.0TYP.
1
A_4.1TYP.
1
A_4.1TYP.
3
A_4.1TYP.
2
A_4.1TYP.14
A_4.1
7
A_4.3
4
A_4.3
5
A_4.3
4
A_4.0
6
A_4.0
10
A_4.0
2
A_4.0
1
A_4.0 OPP.13
A_4.0 OPP.
2
A_4.0
OPP.
2
A_4.0
OPP.
OPP.
1
A_4.1
3
A_4.1
OPP.
OPP.
6
A_4.3
WATER FEATURE
13
A_4.0 OPP.
4
A_4.0
4
A_4.0
ENTRY COURT
WATER FEATURE
HVACHVACwm
GM
LANDSCAPE PLAN 1
LANDSCAPE PLAN
1/4"=1'-0"L_1.0
NOTES
PLANTING NOTES
PROVIDE AUTOMATIC IRRIGATION FOR ALL PLANTED AREAS. IRRIGATION TO CONSIST OF A
COMBINATION OF LOW VOLUME DRIP TUBING AND MICRO-SPRAY HEADS CONTROLLED BY
AUTOMATIC VALVES AND A FLEXIBLE AUTOMATIC CONTROLLER HAVING WEATHER SENSITIVITY
AND A MASTER CONTROL VALVE. A REDUCED PRESSURE BACKFLOW PREVENTER WILL BE USED
AND WILL NOT BE LOCATED IN THE RIGHT-OF-WAY.
THIS PRELIMINARY PLAN IS NOT INTENDED TO BE USED AS A CONSTRUCTION DOCUMENT.
PROPERTY LINE
PROPERTY LINE 4'-0"4'-0"10'-0" TO ARCHITECTURAL TRIM25'-0"
ASSESSORS PARCEL#: 458 672 22
Scale:WALZ : ARCHITECTURE
Client:Project:Legal Description:Date:THIS DRAWING IS THE PROPERTY OF RRLA, AND
IS NOT TO BE REPRODUCED OR COPIED IN
WHOLE OR IN PART WITHOUT PERMISSION. IT IS
NOT TO BE USED ON ANY OTHER PROJECT AND
IS TO BE RETURNED ON REQUEST.
BY
Corrections/Changes:# REVISIONSDATE
Seal/Signature:PERMIT
Issued For:Drawing No:Consultants:Note:Drawing:2020.12.14CHRISTIAN FANTICOLA
FANTICOLA.LINDA ISLE
80 LINDA ISLE
JR Walz
23 Coporate Plaza, Suite 150
Newport Beach, CA 92660
949.836.5977
jr@walzarchitecture.com
RRLARichard Ramsey
Landscape Architect
3035 Bern Drive Laguna Beach, CA 92651 949-290-9009
RichardFa rr a Ramsey
5
467r
#RR Submittal12/15/20
RRSubmittal 403/30/21
AGA TEQ Agave tequilana 4 - 24" box reaches 6't x 6'w`
Blue Agave
CHO PEL Chondropetalum elephantinum
Large Cape Rush 2 - 25 G 4' t + 5'w
PLANTING LEGEND
EXISTING FICUS
TREE TO REMAIN
DRY CLEAN
CLOSET
SCREENED TRASH AREA
LOCATION OF WINDOWS ON FIRST FLOOR
FOOTPRINT OF NEIGHBORING HOME PROPERTY LINEPROPERTY LINE
PROPERTY LINE
PROPERTY LINEWATER FEATURE
(max. depth 18")
WATER FEATURE NOTES
WATER FEATURE WILL NOT EXCEED 18" DEPTH. WATER FEATURE WILL USE A SUBMERSIBLE
PUMP. FILTRATION AND PUMP EQUIPMENT TO BE BURIED IN AN ENCLOSED UNDERGROUND
VAULT AND THE VAULT COVER WILL BE FLUSH WITH THE SURROUNDING WALKWAY OR GROUND
COVER. SOUND TRANSMISSION WILL NOT EXCEED 55 DB BETWEEN THE HOURS OF
7:00AM-10:00PM AND 50 DB BETWEEN THE HOURS OF 10:00PM-7:00AM AT THE TIME OF
INSTALLATION AS MEASURED AT THE PROPERTY LINE. PER NBMC 10.26.025. THE SOUND LEVELS
OUTLINED ABOVE WILLBE MAINTAINED AT ALL TIMES. PER NBMC 10.26.025
CHO PEL
CHO PEL
AGA TEQ WATER FEATURE
EQUIP. VAULT
JOB: 75-74 DATE: 3/26/20 949 422-1869 CELL
949 858-2924 OFFICE
LAGUNA HILLS, CA 92653
23016 LAKE FOREST DR. #409
RdM SURVEYING INC.
RON MIEDEMA L.S. 4653
RDMSURVEYING@COX.NET
DESCRIPTION
LEGEND
PREPARED FOR:TOPOGRAPHIC SURVEY LEGAL DESCRIPTION:BENCH MARK:ADDRESS OF PROJECT:
XX
123.45
P.P.
WM
F.F.
G.F.
CONC.
F.S.
M.H.
P
A.C.
T.G.
MEAS. ELEVATIONS
TOP-GRATE
ASPHALT
PLANTER
MAN-HOLE
FINISH SURFACE
CONCRETE
GARAGE FLOOR
FINISH FLOOR
WATER METER
POWER POLE
FENCE
PROPERTY LINE
BUILDING
WALL
DECK
BRICK
REC. BRG. & DIST.
NATURAL GRADEN.G.
BENCH MARK
SCALE 1"=8’
0’8’16’
80 LINDA ISLE
NEWPORT BEACH, CA
C.F. CURB FACE
C.P. CONTROL POINT
FL FLOWLINE
LEAD & TAGL&T
TC TOP OF CURB
T.O.R. TOP OF ROOF
S&W SPIKE & WASHER
10.01FS
10.38FF
10.18FS
10.2FS
10.2FS
10.2FS
10.1FS
10.1FS
10.10FS
10.09FS
10.40TW
10.31TW
16.18TW
16.16TW
9.45FF
9.50FF
10.57FF
9.52FS
9.33FS
9.22FS
9.24FS
9.39FS
9.62FS
10.37FS
10.22FS
10.03FS
9.99FS
9.86GF 10.08GF
15.25TW
11.99TW
12.01TW
9.61TW
11.67TW
11.65TW
15.18TW
15.56TW
15.55TW
15.63TW
33.66 RIDGE
36.15 RIDGE
27.36
EAVE
9.14FS
9.08FS
9.61TW
8.69 DECK
8.77
DECK
8.98 DECK
MULTI TRUNK
9.94FS
9.61TC 9.60TC 9.54TC 9.57TC
9.67TC
9.70TC 9.04FL 8.94FL
9.82TC
9.76TC
9.64TC
10.18NG
9.71FS 9.71FS 9.73FS
WM WM
36" TREE
9.11
9.75
CHIS. BOX
LEAD
8.94 LEAD
8.62L&T
9.27
L&T L.S.4653
GM GM
3.9
3.9
4.2
3.7
25.0
14.0
2.0
5.6
1.2
X X
X X
24" TREE
COLUMN
COLUMN
ROOF SUPPORT
ROOF SUPPORT
ROOF SUPPORT
GRADE
BREAK
RAMP TO
DOCK
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
JR WALZ LOT 80 OF TRACT MAP NO. 4003 NB 4-39-77
P
P
P
P
P
P
P
P
P
P P P
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
CONC.
BUILDING
2 STORY
BUILDING
2 STORY
BUILDING
ELEVATION = 10.85
NAVD 88 DATUM
P
P
3.0 GUTTER
GARAGE
SETBACK LINE
N88%%D19’56"E 45.00’
N88%%D19’56"E 45.00’
N1%%D40’04"W 124.00’
N1%%D40’04"W 124.00’
11.7TW
9.8FS
9.7FS
9.9FS
10.0FS
9.6FS
9.6FS
9.2FS 9.2FS
9.2FS
LINDA ISLE
CENTER LINE
PROPERTY
LINE
PROPERTY
LINE
PROPERTY
LINE
PROPERTY LINE
9.9NG
RON
MIEDEMA
NO. 4653
EXP. 9/30/21
L I C E N S E D L A N D S U R V E Y O R
S T A T E
O F C A L I F O R N I A
60’ NTS 60’ NTS 60 FOOT EASEMENT FOR PIER AND RELATED USE
PA2020-360
PROPOSED RESIDENCEFF= 10.538" SS lat.8" WWWLEGEND
SCOPE OF WORKCITY OF NEWPORT BEACH NOTESADDITIONAL NOTESSURVEYORDETAILCATCH BASIN FILTER INSERT139 Avenida NavarroSan Clemente, CA 92672949.492.8586www.toalengineering.comCIVIL ENGINEERINGLAND SURVEYINGSTORMWATER QUALITYPA2020-360
PROPOSED RESIDENCEFF= 10.538" SS lat.8" WWW SURVEYORLEGENDNOTEEROSION CONTROL BMPsTEMPORARY SEDIMENT CONTROLWIND EROSION CONTROLTRACKING CONTROLWASTE MANAGEMENT AND MATERIALS POLLUTION CONTROLNON-STORMWATER MANAGEMENTYEAR-ROUND BMP REQUIREMENTS139 Avenida NavarroSan Clemente, CA 92672949.492.8586www.toalengineering.comCIVIL ENGINEERINGLAND SURVEYINGSTORMWATER QUALITYPA2020-360