HomeMy WebLinkAboutX2018-1591 - MiscMIDGET A Professional Inspection Service 365 Mainsail Road, Oceanside, CA 92054 Project Name & Address Report of Special Inspection Office; (760) 757-0556 Cell: (949) 370-7922 Fax: (760)757-1064. I Permit Number InspectionType(s) Inspection Date( s) <._ " 6 ``'a1 -� [ ] Periodic [ ] Continuous Describe Inspection Made, including Locations: <) t ?M i ".. 5 1 -� t \. 0 List Tests Made: Total Inspection Time Each Day: Date Hours List Items Requiring Correction, include uncorrected items previously listed Comments: r To the best of my knowledge, the work inspected was in accordance with the Building Department approved design drawings, specifications and applicable workmanship provisions of the U.B.C. except as noted above. All inspections based on four hour minimum. Inspections exceeding four hours will be billed at eight hours. Any inspections beginning before 12:00 noon and end after 12:00 noon will be billed as eight hours F Signed: i A 'e r, i Date Print FullName: + A r `.(. Registration No FORMSI-02,01 ESI/FME INC STRUCTURAL ENGINEERS & CONSULTANTS EMAIL/FAX TRANSMITTAL DATE: 4/15/2019 JOB No: COMPANY, Renaissance Custom Builders, Inc. PROJECT: ATTN: Kent Johnsen FROM: EMAIL/FAX: kjohnsen@rcb-inc.com No. OF PAGES ADDITIONAL INFORMATION: Refer to attached details for Epoxy or Titen fix on missing anchor bolts. H094 Gaytan Residence Dale 3 QROFESS/0N ORE ^O v 4 Z �O C304 v,m l CIVIL QFyC��P F Of CALIF 1800 E. 16th Street, Santa Ana, CA 92701 Tel: (714) 835-2800 Fax: (714) 835-2819 ESI/FME INC STRUCTURAL ENGINEERS & CONSULTANTS EMAIL/FAX TRANSMITTAL 1. RETRO—FIT MISSING 1/2" DIAMETER ANCHOR BOLT w/ 1/2" DIA. A-307 ALL—THREAD (ICC ESR -2508) BOLTS PER TABLE BELOW. Exterior Wall I Ed in. d In. A.B. Ouantlt Diometer IMln. Spacinal SPECIAL INSPECTION 2x4 ,-7 B" s" 'L ,L" 0 8" REQUIRED 2x6 3 a t 1/2" a 8" DETAIL MAY BE USED Interior Wall Ed in. d (in.) A.B. Quantity Diameter Min. Spacing IN SEISMIC DESIGN A—E 2x4 & 2x6 fL01 Wall 5*' (2) 1/2" (a) 0 12" WIDE FTG g" ONTLEGORIES (1) 1/2' (a) 0 15" WIDE FTG g" IAII VQlaes are ASD (a) Anchor bolts not located at shear walls may be replaced w/ (1) 1/2° dia. Alf—Thread with SET—XP Epoxy bolt per missing anchor bolt. 1 1 Ed Ed a 1,71 o a ` o 4 a _ a I va a= yy 7 INTERIOR 4 v NOTE: EPDXY REPLACEMENT BOLTS MAY BE DISTRIBUTED WITHIN EXTERIOR LENGTH OF SHEAR WALL, ESI FME «x T'c min = 2,500 psi 12/02/09 ANCHOR BOLT RETROFIT- SET XP ES -250 1800 E. 16th Street, Santa Ana, CA 92701 Tel: (714) 835-2800 Fax: (714) 835-2819 ESI/FME INC STRUCTURAL ENGINEERS & CONSULTANTS EMAIL/FAX TRANSMITTAL 1/2" DIA. TITEN—HD (ICC ESR -2713) BOLTS PER TABLE BELOW. Interior Wall Ed in. in. A.B. Quantity Diameter Min. Spacing 2x4 & 2x6 � Of Wall 4" (2) 1/2" (a) 6" (a) Anchor bolts not located at shear walls may be replaced w/ (1) 1/2" dia. TITEN—HD bolt per missing anchor bolt. SPECIAL INSPECTION REQUIRED DETAIL TO BE USED IN SEISMIC DESIGN CATEGORIES A—D ONLY All Values are ASO i --- o -I _ a d v n. � I a INTERIOR s NOTE: TfiEN REPLACEMENT BOLTS MAY BE DISTRIBUTED WITHIN EXTERIOR LENGTH OF SHEAR WALL. ESI/5 * f'c min = 2,500 psi 1191o" ANCHOR BOLT RETROFIT-TITEN HDICC ESR -271: 1800 E. 16th Street, Santa Ana, CA 92701 Tel: (714) 835-2800 Fax: (714) 835-2819 MIDGET A Professional Inspection Service 365 Mainsail Road, Oceanside, CA 92054 Project Name & Address Report of Special Inspection Office; (760) 757-0556 Cell: (949) 370-7922 Fax: (760)757-1064. Permit Number Inspection Type(s) Inspection Date(s) ' [ j Periodic [ ] Continuous Describe Inspection Made, including Locations: " T List Tests Made: Total Inspection Time Each Day: Date Hours List Items Requiring Correction, include uncorrected items previously listed To the best of my knowledge, the work inspected was in accordance with the Building Department approved design drawings, specifications. and applicable workmanship provisions of the U.B.C. except as noted above. All inspections based on four hour minimum. Inspections exceeding four hours will be billed at eight hours. Any inspections beginning before 12:00 noon and end after 12:00 noon will be billed as eight hours Signed: Date Print Full Name: Registration No. FORM SI -02,01 ESI/FME INC STRUCTURAL ENGINEERS & CONSULTANTS EMAIL/FAX TRANSMITTAL DATE: 10/26/2018 JOB No: H094 COMPANY Renaissance Custom Builders, Inc. PROJECT: Gaytan Residence ATTN: Kent Johnsen FROM: Dale EMAIL: kjohnsen@rch-inc.com No. OF PAGES 1 ADDITIONAL INFORMATION: This letter is to inform you that the foundation engineering for 23 Overlook was done using prescriptive design values from the most current verstion of the CBC and a soils report was not use, nor was it required. e�OF€55/0 C 7 .lI OF CARE® 1800 E. 16th Street, Santa Ana, CA 92701 Tel: (714) 835-2800 Fax: (714) 835-2819 ESI/FME INC STRUCTURAL ENGINEERS & CONSULTANTS EMAIL/FAX TRANSMITTAL DATE: 10/26/2018 JOB No: H094 COMPANY Renaissance Custom Builders, Inc. PROJECT: Gaytan Residence ATTN: Kent Johnsen FROM: Dale EMAIL: kjohnsen@rcb-inc.com No. OF PAGES 1 ADDITIONAL INFORMATION: This letter is to inform you that the foundation engineering for 23 Overlook was done using prescriptive design values from the most current verstion of the CBC and a soils report was not use, nor was it required. QROFESS/O on. < v w0 C30 7 �m A q7. CIV I11 P OF CA1-1F0 1900 E. 16th Street, Santa Ana, CA 92701 Tel: (714) 835-2800 Fax: (714) 835-2819 MIDGET A Professional Inspection Service 365 Mainsail Road, Oceanside, CA 92054 Report of Special Inspection Project Name & Address e ,4 h•, a '- Office; (760) 757-0556 Cell: (949) 370-7922 Fax: (760) 757-1064 Permit Number Inspection s Inspection Date(s) [ J Periodic [ J Continuous jai:. List Tests Made: Total Inspection Time Each Day: Date Hours List Items Requiring Correction, include uncorrected items previously listed To the best of my knowledge, the work inspected was in accordance with the Building Department approved design drawings, specifications and applicable workmanship provisions of the U.B.C. except as noted above. All inspections based on four hour minimum. Inspections exceeding four hours will be billed at eight hours. Any inspections beginning before 12:00 noon and end after 12:00 noon will be billed as eight hours r Signed: i Date i Print Full Name: Registration No FORM SI -02.01