HomeMy WebLinkAboutF2022-0007 - MiscCALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 0 LISTING No. 7'I25-078:¢a01fi✓� Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Cooper Wheelock Inc.7246 16th St. E., Ste. 105, Sarasota, FL 34243 Contact: Thomas Conover (941) 487-2336 Email: thomaslconover@eaton.com DESIGN: Exceder Series: Models ST st HS Fiomsffobe and HN horn. Model ST is a synchronous _ and non -synchronous strobe light. Model HS a visual/audible appliance and Model HN is an audible signal appliance. All units followed by R (red) or W (white). Additionally, a'C' may be added for ceiling models and/or a'-NR' may be added for non-resettable models. For non -NR models and optional 'S'for silver fascia may be added*. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 12 VDC/24VDC/FWR Candela (wall)*: 15, 15/75, 30, 75, 95, 110, 135 & 185 Candela (ceiling)*: 15, 30, 60, 75, 95, 115, 150, & 177 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. All models are for indoor use and for wall mount only or ceiling mount only* MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horn for fire alarm signaling and strobe, horn/strobe for the hearing impaired when used with separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instructions Manual for details. *Rev. 9-24-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued July 01,2021 ,J� une30 2022) Authorized By: DAVID CASTILLO„ M.E., F.P.E. Fire Engineering Division nd Horn Notification Appliances Description: The Wheelock" Excederlm Series of notification appliances feature a sleek modern design that will please building owners with reduced total cost of ownership. Installers will benefit from its comprehensive feature list, including the most candela options in one appliance, low current draw, no tools needed for setting changes, voltage test points, 12/24 VDC operation, universal mounting base and multiple mounting options for both new and retrofit construction. The Wheelock® Excederlm Series incorporates high reliability and high efficiency optics to minimize current draw allowing for a greater number of appliances on the notification appliance circuit. All strobe models feature an industry first of 8 candela settings on a single appliance. Models with an audible feature 3 sound settings (90, 95, 99 dB). All switches to change settings, can be set without the use of a tool and are located behind the appliance to prevent tampering. Wall models feature voltage test points to take readings with a voltage meter for troubleshooting and AHJ inspection. The Wheelock® Exceder"m Series of wall and ceiling notification appliances feature a Universal Mounting Base (UMB) designed to simplify the installation and testing of horns, strobes, and combination horn strobes. The separate universal mounting base can be pre -wired to allow full testing of circuit wiring before the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt, dust, paint and damage to the contacts. The Contact Cover also acts as a shunting device to allow pre -wire testing forcommon wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while it is on the UMB. When the Contact Cover is removed the circuit will show an open until the appliance is installed. The UMB allows for consistent installation and easy replacement of appliances if required. Wall models provide an optional locking screw for extra secure installation, while the ceiling models provide a captivated screw to prevent the screw from falling during installation. COOPER Notification -Save up to 48% in current draw* - Up to 9 models now in 1 appliance - Save up to 14% cost of installation" Ali upSleek Modern Aesthetics Finger Slide Switches Voltage Test Points Multiple Voltages 3 Audible Settings sa, 95, ss dB 8 Candela Settings *** Wall- 15/1575/80/75/95/1101135/185 Ceiling - 15/30160/75/95/115/150/177 CO) "� Universal Mounting Base *** V Ceiling and Wall Mounts to 5 Backbox Types toEnvironmentally Friendly Low Current Oraw Compatibility and Requirements - Synchronize using the Wheelock' Sync Modules or panels with built-in Wheelock' Patented 5ync Protocol Compatiblewith U L "Regulated Voltage" using filtered VDC or unfiltered VRMS inputvoltage Strobes produce 1 flash per second over the "Regulated Voltage"range * Compared to competitive models *** Patented -- Compared to previous models NOTE: All CAUTIONS. and WARNINGS are identified by the symbol A. All warnings -are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING. THIS PRODUCT. VISIT WWW.000PERNOTIFICATIOMCOM OR CONTACT COOPER NOTIFICATION -FOR THE CURRENT INSTALLATION - INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: General Notes; • Strobes are designed to Flash at 1 flash per second minimum over their "Regulated Voltage Range". All candela ratings represent minimum effective strobe intensity based on UL Standard 1971. • Series Exceder.Strobe products are Listed under UL Standards 1971 and 464. for indoor use with a temperature range of 32°.F to 120°F (0°C to 49"C) and maximum humidity of 93%(t 2%)UL 464.(85%UL 1971). • Series Exceder horns are under UL Standard 464 foraudible signal appliances (indoor use only). I Low Current Draw Strobe Ratings per UL Standard 1971 = Fewer Power Supplies UL Max Current* 24VDC/24FWR 12VDC Model Regulated Voltage Range VDC 15 15/75 30 60 75 95 "0 115 135 150 177 185 15 15/75 ST 8.0-33.0 0.057 0.070 0.085 0.135 0.163 0.182 0.205 0.253 0,110 0.140 I C 8.0-33.0 0.061 0.085 0.103 0.135 0.163 0.182 0.205 0.253 0.110 Horn Strobe Ratings per UL 1971 & Anechoic at 24 VDC UL Max Current* at 24VDC Anechoic 99 dBA 12 VDC Regulated Voltage Model 75 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.082 0.095 0.102 0.148 0.176 0.197 0.242 0.282 0.125 0.159 FISC 8.0-33.0 0.082 0.102 0.141 0.148 0.176 0.197 0.242 0.282 0.125 24 VDC 12 VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.073 0.083 0.087 0.139 0.163 0.186 0.230 0.272 0.122 0.153 HSC 8.0-33.0 0.073 0.087 0.128 0.139 0.163 0.186 0.230 0.272 0.122 24 VDC 12VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.065 0.075 0.084 0.136 0.157 0.184 0.226 0.267 0.120 0.148 HSC 8.0-33.0 0.065 0.084 0.120 0.136 0.157 0.184 0.226 0.267 0.120 - Horn Ratings per UL Anechoic Model Regulated Voltage 99 dB 95 dB 90dB RangeVDC '"'• -..,. - -' HN 16-33.0 0.064 0.044 0.022 HNC 16-33.0 0.084 0.044 0.022 HN 8.0-17.5 0.047 0.026 0.017 HNC 8.0-17.5 0.047 0.026 0.017 * UL max current rating is the maximum RMS current within the listed voltage range (16-33 VDC:for 24 VDC units). For strobes the UL max current is usually atthe minimum listed voltage. (16: VDC for 24 VDC units). For audibles the max current is usually at the maximum listed voltage (33 VDC for 24 VDC units). For unfiltered ratings, see installation instructions. Specification & Ordering Information Sync w/ Model Strobe DSM or 12/24 VDC' Mounting Candela Wheelock Power Options ,• Supplies HSR 1511575/30/75/951110/135/185 X X UMB** HSW 1511575130175195/110/135/185 X X UMB" HSRC 15/30/60/75/95/115/153/177 X X UMB" HSWC 15/30/60/75/95/1151150/177 X X UMB** STIR 15/1575/30/75/95/110/135/185 X X UMB** W ST 15/1575/30175/95/1101135/185 X X UMB** STRC 15130/60/75/95/1151150/177 X X UMB** ' STWC • 15/30/60/75/951115/150/177 X X UMB** • HNR ' • X X UMB** HNW X X UMB** HNRC „ X X UMB** HNWC X X UMB** NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc., tlba Cooper Notification standard terms and conditions. - Architects and Engineers Specifications The notification appliances shall be Wheelock` Exced&- Series HS Audible Strobe appliances, Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals. The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing -Impaired) for Indoor Fire Protection Service. The Series HS and HNAudibles shall be UL Listed under Standard 464 (Fire Protective Signaling). All Series shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuitwiring by a Fire Alarm Control Panel (FACP) with the ability to operate from 8 to 33 VDC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series shall be of low current design. Where Multi -Candela appliances are specified, the strobe intensity shall have 8 field selectable settings at 15, 15/75, 30, 75, 95, 110, 135, 185 candela for wall mount and 15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on -axis is required (e.g. ADA compliance). Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three (3) field selectable settings fordBA levels and shall have a choice of continuous ortemporal (Code 3) audible outputs. The Series HS Audible Strobe, ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base thatshall allow mounting to a single -gang, double -gang, 4-inch square, 3.5-inch octal, 4-inch octal or 100mm European type back boxes. Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel (FACP). The mounting base shall be the same base among all horn, strobe, horn strobe, wall and ceiling models. All notification appliances shall be backwards compatible. The Series HS and ST wall models shall have a low profile measuring 5.24" H x 4.58" W x 2.19" D. Series HN wall shall measure 5.24" H x 4.58" W x 1.6" D. The Series HSC and STC shall been round and have a low profile with a diameter of 6.68" x 2.63" D. Series HNC ceiling shall have a diameter of 6.68" x 1.50" D. When synchronization is required, the appliance shall be compatible with Wneelocke's DSM Sync Modules, Wheelock® Power Supplies or other manufacturer's panels with built-in Wheelock® Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate, the strobe shall revert to a non -synchronized flash -rate and still maintain (1) flash per second over its Regulated Voltage Range. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock® synchronization protocol. Wall Appliances — UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM Ceiling Appliances — UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3YEAR WARRANTY Exceder - Spec Sheet 6/11 Wheelock' INEDG SAFEPATH` WAVE Notification CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THESTATEFIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 0 LISTING No. 7125=0785 015j Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: CoppeiNji dgk.lnc.7246 16th St. E., Ste. 105, Sarasota, FL 34243 Contact: Thomas Conover (941) 487-2336 Email: thomaslconover@eaton.com DESIGN: Models *ET70-241575W, ET70-24MCW, ET70-24MCC, ET70-24MCWH, ET70-24MCCH, *ET80-241575W, ET80-24MCW, ET80-24MCWH, *ET90-241575W, ET90-24MCW, ET90-24MCC, ET90-24MCWH, ET90-24MCCH, E70-24MCW, E70-24MCC, E70-24MCWH, E70-24MCCH, E90-24MCW E90=24MCCE90-24MCWH, and E90-24MCCH multi -candela speaker/strobes. Models E60-R, E60-W, E60-24MCC-FW, E60-24MCCH-FR, E60-24MCCH-FW, E60EXT-R and E60-EXT-W multi -candela speaker/strobes. May be followed by suffixes to designate lens lettering and plate color. *Lens color may be Clear, Red (R), Blue (B), Green (G), or Amber (A). EXT is an extender ring that mounts behind the speaker. Intended for indoor use only. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 16-33 VDC, 25/70 VRMS Flash rate: 60 Flashes/min Candela: MCW=15cd,30cd,75cd or 110cd MCC=15cd,30cd,75cd or 95cd MCWH = 135cd,185cd MCCH = 115cd,177cd *1575 = 15 cd/75cd on axis INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in manner acceptable to the authority having jurisdiction. Models followed by W or WH are wall mounts; C or CH are ceiling mounts. All models are for indoor use. MARKING: Listee's name, model number, electrical and candela rating, and UL label. APPROVAL: Listed as strobe speakers suitable for the hearing impaired when used in conjunction with separately listed electrically compatible fire alarm control units. For synchronization strobes, Models SM-12/24 or DSM-12/24 synchronized control modules (CSFM Listing No. 7300-0785:132) must be used. Refer to manufacturer's Installation Manual for details. NOTE: These units do not generate a temporal pattern signal. If the distinctive three -pulse Temporal Pattern Fire Alarm Evacuation signal (for total evacuation) in accordance with NFPA 72, 2002 Edition is required, the appliance must be used with a fire alarm control unit that can generate the temporal pattern signal. *Rev. 07-30-10 fm itThis listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2021 Authorized By: DAVID CASTILLO„ M.E., F.P.E. Fire Engineering Division Wheelock E70 & E90 Speakers & Speaker Strobes Table 1. Maximum RMS Current UL Max Current (D 24MCW/24MCC 24MCWH/24MCCH Technical Data TD450024EN Regulated Voltage Model Range VDC 15 30 75 95 110 115 135 177 185 E70 16.0-33.0 0.060 0.092 0.165 0.220 0,300 0.420 0 16.0-33.0 0.065 0.105 0.189 0.249 0.300 0.420 Table 2. UL Listed Models and Ratings UL Reverberant dBA at 10 Feet O 118 watts Model O 114 watts 112 watts 1 watts 2 watts E70 Speaker 72 75 78 81 83 E90 Speaker 72 75 78 81 82 E70 Speaker Strobe 71 75 78 81 83 E90 Sneaker Strobe 74 77 80 82 85 Table 3. Specification & Ordering Information Effective April 2018 Mounting Sync w/ DSM or Model Order # Strobe Candela Red White Lettering Wall Ceiling Options Wheelock Power Supplies Speakers E70-R 9865 X No Lettering X P, Cl E70-W 9866 X No Lettering X P E90-R 9875 X No Lettering X Q E90-W 9876 X No Lettering X P, Q Speaker Strobes E70-24MCW-FR 0183 15/30/75/110 X FIRE X P, Q X E70-24MCW-FW 0184 15/30/75/110 X FIRE X P Q X E70-24MCW-NW 9748 15/30p5/110 X No Lettering X P, Q X E70-24MCW-ALR 4123 15/30/75/110 X ALERT X P, Q X E70-24MCW-ALW 4124 15/30775/110 X ALERT X P, (I X E70-24MCWH-FR 0185 135/185 X FIRE X P, (I X E70-24MCWH-FW 0186 135/185 X FIRE X P,Q X E70-24MCWH-ALW 4456 135/185 X ALERT X P,Q X E70-24MCC-ALR 4308 15/30/75/95 X ALERT X P, Q X E70-24MCC-ALW 5838 15/30p5/95 X ALERT X P, Q X E70-24MCC-NW 1000 15/30175/95 X No Lettering X P, Q X E90-24MCC-FR 0191 15/30175/95 X FIRE X P, Q X E90-24MCC-FW 0192 15/30/75/95 X FIRE X p, Q X E90-24MCC-NW 3181 15/30/75/95 X No Lettering X P, Q X E90-24MCC-ALW 4189 15/30175/95 X ALERT X P Q X E90-24MCC-ALR 4309 15/30/75/95 X ALERT X P, Q X Egg-24MCCH-FR 0194 115/177 X FIRE X P, Q X E90-24MCCH-FIN 0193 115/177 X FIRE X P Q X E90-24MCCH-ALR 0980 115/177 X ALERT X P, Q X E90-24MCCH-ALW 2975 1151177 X ALERT X P, Q X E90-24MCCH-NW 2974 115/177 X No Lettering X P, Q X OO RMS current ratings are per UL maximum RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. dBA ratings are based on testing under UL Standard 1480. 1/8 watt tap is for private mode only. Note: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc., doe Eaton standard terms and conditions. EATON www.eatm,x. Technical Data TD450024EN Effective April 2018 Wheelock E70 & E90 Speakers & Speaker Strobes Table 4, Specifications Physical Material Red or white textured UV stabilized, colored impregnated engineered plastic. Exceeds 94V-0 UL flatten ahility rating. Weight E70 Speaker: 1.7 Ibs (0.77 kg); E70 Speaker Strobe 1.8Its (0.82kg); E90 Speaker: 1.516s (0.68 kg); E90 Speaker Strobe 1.6 Lens GE Lexan 943A Dimensions E70 Speaker: 5.13" W x 5.13" H x 0.43"D; E70 Speaker Strobe: 5.13" W x 5.13" H x 2.56"D; E90 Speaker: 7.27" Diameter x 0.43" D; E90 Speaker Strobe: 7.327 Diameter x 2.68" D Operating Temperature Indoor: 33.8"F to 120.2°F DoC to 49°C) and maximum humidity of 93% Mounting & Wire Connections Mounting (indoor only) 4"square backbox with extension ring prevents wire damage; SBB for surface mount of E70 Wire Connections #12through#18 AWG Power & General Operating voltage 25/70 VRMS Strobe Output Rating UL 1971 Strobe Flash Rate Strobes are designed to flash at 1 flash per second Synchronization Models Strobes can be synchronized with Wheelock's DSM Sync Modules, Power Supplies or SAFEPATH products, using Wheelock patented sync protocol Frequency Range 400 Hz to 4000 Hz Architects and Engineers Specifications The speaker appliances shall be Wheelock Series E70 or E90 Speakers and Speaker Strobe appliances or approved equals. The speakers shall be UL Listed under UL 1460 for Fire Protective Service and speakers equipped with strobes shall be listed under UL 1971 for Emergency Devices for the Hearing -Impaired. In addition, the strobes shall be certified to meet the requirements of FCC Part 15, Class A. All speakers shall be designed for a field selectable input of either 25 or 70 VRMS, with selectable power taps from 1/8 watt to 2 watts. All models shall have listed sound output of up to 87 de at 10 feet and a listed frequency response of 400 to 4000 Hz. The speaker shall also incorporate a sealed back construction. All Inputs shall employ terminals that accept #12 to #18 AWG wire sizes. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range. The strobe shall be of low current design. Where Multi -Candela Speaker Strobes are specified, the strobe intensity shall have field selectable settings and shall be rated per UL 1971 at 15/30/75/11 God or 135/185cd for wall mount and 15/30/75/95cd or 115/177cd for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Erma 1000 Eaton Boulevard Cleveland, CH 44122 United States Eston.com Eaton Life safety & mass notification solutions 273 Branchport Ave. Long Branch, NJ 07740 www.aetoo.com/massnotif ication When synchronization is required, the strobe portion of the appliance shall be compatible with Wheelock DSM sync modules, Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non -synchronized flash rate. The speaker and speaker strobe appliances shall be designed for indoor surface or flush mounting. The speaker and speaker strobe shall incorporate a speaker mounting plate with a grille cover which is secured with two screws for a level, aesthetic finish and shall mount to standard electrical hardware requiring no additional trimplate or adapter. The finish of the Series E speakers and strobe speakers shall be red or white. All speaker and speaker strobe appliances shall be backward compatible. UL 1971, UL 1480, CSFM, FCC. ® 2016 Eaton All Rights Reserved Eaton is a registered trademark. _ Printed in USA Publication No. TD450024EN All other trademarks are property Powering Business Worldwide April 2018 of their respective owners. �23L2 -vri0-7 Sri od 91RC-r( S7 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 71( 25-075:0168. Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Cooper Wheelock Inc.7246 16th St. E., Ste. 105, Sarasota, FL 34243 Contact: Thomas Conover (941) 487-2336 Email: thomaslconover@eaton.com DESIGN: Exceder Series: ModeIsST rokieE+I{S, horn stinb-'and HN horn. Model ST is a synchronous and non -synchronous strobe light. Model HS a visual/audible appliance and Model HN is an audible signal appliance. All units followed by R (red) or W (white). Additionally, a 'C' may be added for ceiling models and/or a'-NR' may be added for non-resettable models. For non -NR models and optional'S' for silver fascia may be added*. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 12 VDC/24VDC/FWR Candela (wall)*: 15, 15/75, 30, 75, 95, 110, 135 & 185 Candela (ceiling)*: 15, 30, 60, 75, 95, 115, 150, & 177 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. All models are for indoor use and for wall mount only or ceiling mount only* MARKING: Listee's name, model number, electrical/candela rating, and ILL label. APPROVAL: Listed as horn for fire alarm signaling and strobe, horn/strobe for the hearing impaired when used with separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instructions Manual for details. *Rev. 9-24-09 fro This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not itan endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2021 Authorized By: DAVID CASTILLO„ M.E., F.P.E. Fire Engineering Division 0 "°-Ern>Satro and Horn Notification Appliances Description: The Wheelock® Exceder"m Series of notification appliances feature a sleek modern design that will please building owners with reduced total cost of ownership. Installers will benefit from its comprehensive feature list, including the most candela options in one appliance, low current draw, no tools needed for setting changes, voltage test points, 12124 VDC operation, universal mounting base and multiple mounting options for both new and retrofit construction. The Wheelock® Exceder^^ Series incorporates high reliability and high efficiency optics to minimize current draw allowing fora greater numberof appliances on the notification appliance circuit. All strobe models feature an industry first of 8 candela settings on a single appliance. Modelswith an audible feature 3 sound settings (90, 95, 99 dB). All switches to change settings, can be set without the use ofa tool and are located behind the appliance to prevent tampering. Wall models feature voltage test points to take readings with a voltage meter for troubleshooting and AHJ inspection. The Wheelock® Excedernm Series of wall and ceiling notification appliances feature a Universal Mounting Base (UMB) designed to simplify the installation and testing of horns, strobes, and combination horn strobes. The separate universal mounting base can be pre -wired to allow full testing of circuit wiring before the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt, dust, paint and damage to the contacts. The Contact Cover also acts as a shunting device to allow pre -wire testing forcommon wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while it is on the UMB. When the Contact Cover is removed the circuit will show an open until the appliance is installed. The UMB allows for consistent installation and easy replacement of appliances if required. Wall models provide an optional locking screw for extra secure installation, while the ceiling models provide a captivated screw to prevent the screw from falling during installation. Save up to 48% in current draw* - Up to 9 models now in I appliance - Save up to 14% cost of installation** upSleek Modern Aesthetics WFinger Slide Switches Voltage Test Points Multiple Voltages - 3 Audible Settings 90, 95,99 dB 8 Candela Settings *** Wall- 15/1575/30175/95/110/135/185 Ceiling - 15/30/60/75/95/115/150/177 �"`� Universal Mounting Base *** V Ceiling and Wall Mounts to 5 Backbox Types Environmentally Friendly Low Current Draw Compatibility and Requirements -Synchronize using the Wheelock' Sync Modules or panels with built-in Wheelock' Patented Sync Protocol Compatible with U L"Regulated Voltage" using filtered VDC or unfiltered VRMS input: voltage Strobes produce 1 flash per. second over the "Regulated Voltage" range * Compared to competitive models *** Patented ** Compared to previous models NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING -- OR APPLYING THIS PRODUCT.'VISIT WWW.COOPERNOTIFICATION.COM OR CONTACT COOPER NOTIFICATION FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: General Notes: • Strobes are designed to flash at 1 Flash per second minimum over their' Regulated Voltage Range". All candela ratings represent minimum effective strobe intensity based on UL Standard 1971, Series Exceder Strobe products are Listed under UL Standards 1971 and 464for indoor use with temperaturerange of 32"F to 120°.F (0"C to 49°C) and maximum humidity of93ti (42%) UL464.(85% UL 1971). . •. Series Exceder horns are under ILL Standard 464 for audible signal appliances (Indoor use only). Horn Strobe Ratings per UL 1971 & Anechoic at 24VDC Max Current* at AnechoicUL • dBA 24VDC 12 VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.082 10.095 10.102 0.148 0.176 0.197 0.242 0.282 0.125 0.159 FISC 8.0-33.0 0.082 0.102 0.141 0.148 0.176 0.197 0.242 0.282 0.125 24VDC 12 VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.073 1 0.083 0.087 = 0.139 0.163 0.186 0.230 0.272 0,122 0.153 HSC 8.0-33.0 0.073 "87 0.139 0.163 0.186 0.230 0.272 0.122 • •r 24VDC 12VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.065 0.075 0.084 0.136 0.157 0.184 0.226 0.267 0.120 0.148 HSC 8.0-33.0 0.065 = 0.084 0.120 0.136 0.157 0.184 0.226 0.267 0,120 _ Horn Ratings per UL Anechoic Model Regulated Voltage 99 dB 95 d6 90 dB Range VDC r r j HN 16-33.0 0.064 0.044 0.022 HNC 16-33.0 0.084 0.044 0.022 HN 8.0-17.5 0.047 0.026 0.017 HNC 8.0-17.5 0.047 0.026 0.017 UL max current rating is the maximum RMS.current within the listed voltage range (16-33 VDC for 24 VDC units). For strobes the UL max current is. usually at the minimum listed voltage (16 VDC for 24VDC units). For audibles the max current is usually at the maximum listed voltage (33 VDC for 24 VDC: units). for unfiltered ratings, see installation instructions. Specification & Ordering Information Sync wl Strobe DSM or Mounting Model 12/24 VDC* Candela Wheelock Power Options. Supplies HSR ' 15/1575/30/75/95/110/1351185 X X UMB** HSW 1511575/30175/95/110/1351185 X X UMB** HSRC 15/30/60175/95/115/150/177 X X UMB** HS 15/30160/75/9511151150/177 X X UMB** • , STWC R 1511575/30175/95/110/1351185 X X UMB** STW 1511575/30/75/95/110/1351185 X X UMB** STRC 15/30160175/9511151150/177 X X UMB** ' STWC . 15/30160/75195/115/150/177 X X UMB** • HNR ' X X UMB** HNW X X UMB" * HNRC „ X X UMB" HNWC X X UMB" NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice In accordance with Cooper. Wheelock Inc.,' lbe Cooper. Notification standard terms and conditions. Architects and Engineers Specifications The notification appliances shall be Wheelock` Exceder- Series HS Audible Strobe appliances, Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals. The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing -Impaired) for Indoor Fire Protection Service. The Series HS and HNAudibles shall be UL Listed under Standard 464 (Fire Protective Signaling). All Series shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuitwiring by a Fire Alarm Control Panel (FACP) with the ability to operate from 8 to 33 VDC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series shall be of low current design. Where Multi -Candela appliances are specified, the strobe intensity shall have 8 field selectable settings at 15, 15/75, 30, 75, 95, 110, 135, 185 candela for wall mount and 15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 15175 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on -axis is required (e.g. ADA compliance). Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three (3) field selectable settings fordBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The Series HSAudible Strobe, ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow mounting to a single -gang, double -gang, 4-inch square, 3.5-inch octal, 4-inch octal or 100mm European type back boxes. Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel (FACP). The mounting base shall be the same base among all horn, strobe, horn strobe, wall and ceiling models. All notification appliances shall be backwards compatible. The Series HS and ST wall models shall have a low profile measuring 5.24" H x 4.58" W x 2.19" D. Series HN wall shall measure 5.24" H x 4.58" W x 1.6" D. The Series HSC and STC shall been round and have a low profile with a diameter of 6.68" x 2.63" D. Series HNC ceiling shall have a diameter of 6.68" x 1.50" D. When synchronization is required, the appliance shall be compatible with Wheelock®'s DSM Sync Modules, Wheelock® Power Supplies or other manufacturer's panels with built-in Wheelock® Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate, the strobe shall revert to a non -synchronized flash -rate and still maintain (1) flash per second over its Regulated Voltage Range. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock® synchronization protocol. Wall Appliances — UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM Ceiling Appliances — UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3YEAR WARRANTY Exceder - Spec Sheet 6111 Wheelock' MEDC SAFEPATH° WpvE� Notification Wheelock E70 & E90 Speakers & Speaker Strobes Table 1. Maximum RMS Current UL Max Current O 24MCWH/24MCCH Technical Data TD450024EN Effective April 2018 Regulated Voltage Model Ranga VDC 15 30 75 95 110 115 135 177 185 E70 16.0-33.0 0.060 0.092 0.165 0.220 0.300 0.420 go 16.0-33.0 0.065 0.105 0.189 0.249 0.300 0.420 Table 2. UL Listed Models and Ratings UL Reverberant dBA at 10 Feet ( 1/8 watts Model Os 114 watts 112 watts 1 watts 2 watts E70 Speaker 72 75 78 81 83 E90 Speaker 72 75 78 81 82 E70 Speaker Strobe 71 75 7B 81 83 E90 Sneaker Strobe 74 77 80 82 85 Table 3. Specification & Ordering Information Mounting Sync w/ DSM or Model Order N Strobe Candela Red White Lettering Wall Ceiling Options Wheelock Power Supplies Speakers E70-R 9865 X No Lettering X P, Q E70-W 9866 X No Lettering X E90-R 9875 X No Lettering X PP, Q E90-W 9876 X No Lettering X P Q Speaker Strobes E70-24MCW-FR 0183 15/30/75/110 X FIRE X P, Q X E70-24MCW-FW 0184 15/30p5/110 X FIRE X P, Q X E70-24MCW-NW 9748 15/30/75/110 X No Lettering X P, (I X E70-24MCW-ALB 4123 15/30/751110 X ALERT X P, Q X E70-24MCW-ALW 4124 15/30/75/110 X ALERT X P,a X E70-24MCWH-FR 0185 135/185 X FIRE X P,a X E70-24MCWH-FW 0186 135/185 X FIRE X P, Cl X E70-24MCWH-ALW 4456 135/185 X ALERT X P,Q X E70-24MCC-ALR 4308 15/30/75/95 X ALERT X P, E70-24MCC-ALW 5838 15/30/75/95 X ALERT PQ X E70-24MCC-NW 1000 15/30/75/95 X No Lettering X P Q X E90-24MCC-FR 0191 15/30/75/95 X FIRE X P, Q X E90-24MCC-FW 0192 15/30175/95 X FIRE X p, Q X E90-24MCC-NW 3181 15/30/75/95 X No Lettering X P, Q X E90-24MCC-ALW 4189 15/30/75/95 X ALERT X P, Q X E90-24MCC-ALR 4309 15/30/75/95 X ALERT X P, Q X E9D-24MCCH-FR 0194 115/177 X FIRE X P, Q X E90-24MCCH-FW 0193 115/177 X FIRE X P, Q X E90-24MCCH-ALR 0980 115/177 X ALERT X P, Q X E9D-24MCCH-ALW 2975 115/177 X ALERT X P, Q X E90-24MCCH-NW 2974 115/177 X No Lettering X P, Q X i0 RMS current ratings are per UL maximum RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24, units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. b dBA ratings are based on testing under UL Standard 1480. c 1/8 watt tap is for private mode only. Note: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc., dba Eaton standard terms and conditions. EATONw eatonxam 3 Technical Data TD450024EN Effective April 201 B Table 4. Specifications Wheelock E70 & E90 Speakers & Speaker Strobes Physical Material Red or white textured UV stabilized, colored impregnated engineered plastic. Exceeds 94V-0 ILL flammability rating. Weight E70 Speaker: 1.7 Ids (0.77 kg); E70 Speaker Strobe 1.81bs (0.82kg); E90 Speaker: 1.516s (0.68 kg); E90 Speaker Strobe 1.6 GE Lexan 943A Dimensions E70 Speaker: 5.13" W x 5.13" H x 0.43"D; E70 Speaker Strobe: 5.13" W x 5.13" H x 2.56"D; E90 Speaker: 7.27" Diameter x 0.43" D; E90 Speaker Strobe: 7.327 Diameter x 2.68" D Operating Temperature Indoor: 33.8"F to 120.2°F (0"C to 49"C) and maximum humidity of 93% Mounting & Wire Connections Mounting (indoor only) 4"square backbox with extension ring prevents wire damage; SBB for surface mount of E70 Wire Connections #12 through#18 AWE Power & General Operating voltage 25/70 VRMS Strobe Output Rating UL 1971 Strobe Flash Rate Strobes are designed to flash at 1 flash per second Synchronization Models Strobes can be synchronized with Wheelock's DSM Sync Modules, Power Supplies or SAFEPATH products, using Wheelock patented sync protocol Frequency Range 400 Hz to 4000 Hz Architects and Engineers Specifications The speaker appliances shall be Wheelock Series E70 or E90 Speakers and Speaker Strobe appliances or approved equals. The speakers shall be UL Listed under UL 1480 for Fire Protective Service and speakers equipped with strobes shall be listed under UL 1971 for Emergency Devices for the Hearing -Impaired. In addition, the strobes shall be certified to meet the requirements of FCC Part 15, Class A. All speakers shall be designed for a field selectable input of either 25 or 70 VRMS, with selectable power taps from 1/8 watt to 2 watts. All models shall have listed sound output of up to 87 dB at 10 feet and a listed frequency response of 400 to 4000 Hz. The speaker shall also incorporate a sealed back construction. All inputs shall employ terminals that accept #12 to #18 AWG wire sizes. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range. The strobe shall be of low current design. Where Multi -Candela Speaker Strobes are specified, the strobe intensity shall have field selectable settings and shall be rated per UL 1971 at 15/30/75/110cd or 135/185cd for wall mount and 15/30/75/95cd or 115/177cd for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton cam Eaton Life safety & mass notification solutions 273 Branahport Ave. Long Branch, NJ 07740 wwweaton.com/massnot[fication When synchronization Is required, the strobe portion of the appliance shall be compatible with Wheelock DSM sync modules, Wheelock Power Supplies or other manufacturers panels incorporating the Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non -synchronized flash rate. The speaker and speaker strobe appliances shall be designed for indoor surface or flush mounting. The speaker and speaker strobe shall incorporate a speaker mounting plate with a grille cover which Is secured with two screws for a level, aesthetic finish and shall mount to standard electrical hardware requiring no additional trimplate or adapter. The finish of the Series E speakers and strobe speakers shall be red or white. All speaker and speaker strobe appliances shall be backward compatible. UL 1971, UL 1480, CSFM, FCC, O 2018 Eaton All nights Reserved Eaton is a registered trademark. IT Printed in USA Publication No, TD450024EN All other trademarks are property Powering Business Worldwide April 2016 of their respective owners.