1=1/2" Snap Lock
Engineered Panel Clip
Application
Standing seam panel clips used for attachment of snap lock
type panels wherein mechanical seaming is not required
Features and Benefits
• Manufactured from high quality, corrosion resistant steel
meeting strict mechanical property requirements
• Tightly controlled manufacturing tolerances for a secure and
functional fit every time
• Allows unlimited thermal movement. Always follow the
standing seam panel manufacturer's details and instructions
on proper use, location and performance values as well as
properly fixing their respective roof panels to the structure to
prevent uncontrolled sliding
Product Selection
Material No.
Item
I Description
Carton Wt. (Ibs.)
I Carton Qtv.
1023821
1-1/2" Snap lock clip
18 ga. 0.2 mm) G-90 Galvanized
38
250
1319660
1-1/2" Snap lock clip
18 ga. (1.2 mm) 304SS
42
250
(3.05)
0.120' (9.40)
0.370"
(3e.35
(3.01)
0.1 s• 0.15•
Installation and Application Considerations
• Compatible with:
• Quadro 1-1/2" Snap
BUILDING DIVISION,
W. E.S.
CAD-1023821-A'
Specifications
Height:
Width:
Holes:
1.51" (38.35 mm)
3.50" (88.90 mm)
2-hole
Refer to SFS standing seam fastener offering for panel clip
attachment options
Always consult with panel manufacturer or design engineer
to ensure proper clip recommendations
us Canada Metric values are approximate conversions.
T 800 234 4533 T 866 847 5400 All mformationisnon-binding and without guarantee. Before using the products, all specifications and calculations
must be checked by a suitably qualified parson and local regulations must be observed. This document is subject
us.sfs.com ea.sfs.eom to revision. We reserve the right to make technical changes.(09/2021, V1.01)
Mrs
#10 Type A Pancake
SSR Panel Clip to Wood Fastener
Features and Benefits Application
• Pancake head low profile fits under most panel profiles Standing seam panel clip attachment to wood substrate
• Type A drill point for fast installation
• #2 square drive provides driving stability
• Zinc plated
Product Selection
Material No.
Fastener Length
Thread Length'*
Description
Carton
Wt. (ibs.)
Carton
Oty.
(in)
(Min)
1545869
V
25
Full
CSTA-#10xl-PC-SQ2
36
5,000
1545862
1-1/2"
38
Full
CSTA-#10x1-1/2-PC-SQ2
25
2,500
1545882
2"
51
Full
CSTA-#10x2-PC-SO2
28
2,000
Plain product bagged 250 pieces, unless otherwise noted.
*Note -Thread length measured from tip of the point td top of the threads.
N
US
Canada Metric values are approximate conversions.
T 800 234 4533
T 866 847 5400 All information is non -binding and without guarantee. Before using the products, all specifications and calculations LL;
us.sfs.cem
must be chocked by a suitably qualified person and local regulations must be observed. This document is subject w
ca.sfs.cem to revision. We reserve the right to make technical changes.(08/2021, V1.01)
SFS
#10 Type A Pancake
SSR Panel Clip to Wood Fastener
If1.01
(1. BS)
0.074"
Product Specifications
Diameter:
#10 (4.83mm)
Threads Per Inch:
12
Head Style:
Pancake
Drive:
#2 square
NOMINAL LENGTH
45' Sharp
Point
(3.3) (4.85)
0A 30" 0.1911,
inor Diem. Major Diem.
CSTA-#10xL-PC-S02-RevI R
Drill Point: Type A
Thread Major Dia: 0.191" (4.85 mm)
Thread Minor Dia: 0.130" (3.3mm)
Performance Datat,'
Material Strength
Pull Out Strength Wood: SPF
Tensile 1825 Ibf / 81111 N
1" (25.4 mm) penetration 544 Ibf / 2420 N
Shear 1535.Ibf / 6828 N
1-1/2" (38.1 mm) penetration 995 Ibf / 4426 N
Torsional
60 Ibf-in / 6.8 N m
Pull out strength values may vary from tested loads depending upon specific wood density variations
2 PLK 12403
Installation and Application Considerations
Tools: 0-2500 rpm screw gun equipped with depth sensing
nose piece.
Use of impact guns or hammer drills is not
recommended.
Special care needs to be taken when installing #10 Type A
Pancake clip fasteners into wood substrate less than 1" in
thickness. Stripping or partially stripping the fastener out
during installation compromises the clamp load and can
affect the performance of the fastener.
u3 Canada Metric values are approximate conversions.
T 800 234 4533 T 866 847 5400 All information is non -binding and without guarantee. Before using the products, all specifications andcalculations
must be checked by a suitably qualified person and local regulations must be observed. This document is subject
us.sfs.com ca.sfs.com to revision. We reserve the right to make technical changes.(08/2021, V1.01)
July 30, 2021
Ironridge Inc
28357 Industrial Boulevard
Hayward, CA 94545
TEL: 800-227-9523
Attn.: Engineering Department
Re: Engineering Certification for the Ironridge— Lynx Standing Seam Roof Clamp
Ironridge — Lynx Standing Seam Roof Clamp
The Ironridge Lynx is an extruded aluminum clamp intended to secure PV modules to existing standing seam roofs.
PZSE, Inc. —Structural Engineers has reviewed the Ironridge - Lynx and specifically the Martin Testing Laboratories
—Standing Seam PV Mount tests (MJO: 3888-01) for Uplift and Lateral strength. This letter certifies the allowable
capacities for Ironridge - Lynx and all information, data and analysis within follows the structural requirements of
the following Reference Documents:
1. Minimum Design Loads for Buildings and other Structures, ASCE/SEI 7-10/7-16
2. 2015/2018 International Building Code, by International Code Council, Inc
3. 2019 California Building Code, by the California Building Standards Commission
4. AC 428, Acceptance criteria for modular framing systems used to support Photovoltaic (PV) Panels.
Standing Seam Roof Profiles & Limitations
The Ironridge - Lynx may be attached to any standing seam roof ("Folding" Styles Profile, "Snapping" Style Profiles,
etc.) where the vertical seam height is at least 1.0" and the horizontal seam width is a maximum of 0.5".
"Folding" Styles Profiles:
/z' MAX 2' MAX
UL T
"Snapping" Style Profiles:
%2' MAX 2" MAX
BUILDING DIVISION
AN - 8 2022
1478 Stone Point Drive, Suite 190, Roseville, CA 95661
1 916.961.3960 F 916.961.3965 `n' www.pzse.com t of 3
Experience I Intoyrity I Empowerment
Designer Responsibility
The Ironridge - Lynx standing seam roof clamp is intended to be used under the responsible charge of a registered
design professional where required by the authority having jurisdiction. In all cases, the Ultimate Values shall be
reduced by an appropriate Factor of Safety under the direction of a design professional with sufficient structural
engineering knowledge and experience to be able to:
Evaluate whether the Ironridge Lynx is applicable to the project, based on the characteristics of the
project, and
Understand and determine the appropriate environmental loading conditions.
The user or design professional in responsible charge assumes full design responsibility. Refer to the
Manufacturer's Installation manual for more information.
The capacity of the building structure to support the loads imposed on the building by the Ironridge Lynx including
the fasteners, attachment to underlying structure, and the capacity of the underlying members are outside the
scope of this certification. The capacity of the building is outside the scope of our review.
If you have any questions on the above, do not hesitate to call.
Prepared By:
PZSE,Inc—Structural Engineers
Roseville,CA
1478 Stone Point Drive, Suite 190, Roseville, CA 95661
1 916.961.3960 F 916.961.3965 w www.pue.com 3 of 3