Structural Calcc�3ations for
SOLAR POWER SYSTEM CO=%INECTION CHECK AT:
3710 SEASHOR7E-- DRIVE
NEWPORT BEACEK:L, CA 92663
Job: RANGER, ROBERT
Prepared For:
GROUNDED ELECTRIC, INC.
P.O. BOX 73548
SAN CLEMENTE, CA 92673
(949)370-8766
Design Criteria
1- Code: CALIFORNIA BLDG CODE 2019 / ASCE 7-16
2 - Wind: 95 MPH, Exposure: D
3 - Wood Species: DF-L No. 2 (SG = 0.5 )
Notice: Use restrictions of these calculations.
The attached Calculations are valid only when bearing original signam� xc hereon.
Contractor/Client to verify existing dimensions/conditions prior to corzstmction
& solar racking is installed per manufacturer span requirements.
The use of these calculations is solely intended for the above mentioned project.
�y�Q�;tJG T RCi
No, C70784
1-844-PV ELITE I info@yoj�rsolarplans.com
3000 E. Birch Street Suite 201 l Brea CA 92821
/5/27/22, 8:19 AM
p ITC Hazards by Location
i
Search Information
Address: 3710 Seashore Dr, Newport Beach, CA 92663,
USA
Coordinates: 33.6171855,-117.9359986
Elevation: 12 ft
Timestamp: 2022-05-27T15:19:28.468Z
Hazard Type: Wind
ATC Hazards by Location
ASCE 7-16 ASCE 7-10
MRI 10-Year 66 mph - - MR1 10-Year 72 mph
MRI25-Year
_---- 71. mph
MR150-Year ,__.........
.. 76 mph
MRI100-Year.------------------
81 mph
Risk Category I
__.__- ------ 89 mph
Risk Category 11-...._........____-._
95 mph
RiskCategorylll
...__. ..... . 102 mph
Risk CategoryIV
........ ..------ 106 mph
MRI25-Year _._..__-------
79 mph
MRI50-Year _.._..__.____..
85 mph
MRI100-Year _----
.------- 91 mph
Risk Category I _....__..._._
100 mph
Risk Category11 ........__.
110 mph
Risk Category III -IV
.._.__... 115 mph
ASCE 7-05
ASCE 7-05 Wind Speed 85 mph
The results indicated here DO NOT reflect any state or local amendments to the values or any delineation lines made during the building
code adoption process. Users should confirm anyoutput obtained from this tool with the local Authority Having Jurisdiction before
Proceeding with design.
Disclaimer
Hazard loads are interpolated from data provided in ASCE 7 and rounded up to the nearest whole integer. Per ASCE 7, islands and coastal
areas outside the. last contour should use thelast wind speed contour of the coastal area — in some cases, this website will extrapolate past
the last wind speed contour and therefore, provide a wind speed that is slightly higher. NOTE: For queries near wind-borne debris region
boundaries, the resulting determination is sensitive to rounding which may affect whether or not it is considered to be within a wind-borne
debris region.
Mountainous terrain, gorges, ocean promontories, and special wind regions shall be examined for unusual wind conditions.
While the information presented on this website is believed to be correct, ATC and its sponsors and contributors assume no responsibility
or liability for its accuracy. The material presented in the report should not be used or relied upon for any specific application without
competent examination and verification of its accuracy, suitability and applicability by engineers or other licensed professionals. ATC does
not intend that the use of this information replace the sound judgment of such competent professionals, having experience and knowledge
in the field of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the results of the
report provided by this website. Users of the information from this website assume all liability arising from such use. Use of the output of
thle wsbsltP. does not Imniv annmval by the oovernlno hnlldlno cods bndip% rP.snonSlhlP.. for hlllldlno nnnp.. annmval and InternrP.tatlon for the
hftps://hazards.atcouncil.org/#/wind?lat=33.6171855&ing=-117,9359986&address=3710 Seashore Dr%2C Newport Beach%2C CA 92663%2C USA 1/2
ASCE 29.4.4 Rooftop Solar Panels Parallel to the Roof Surface on Buildings of All Heights and Roof Slopes
Roof Slope
0
= 10
Roof Shape
Gable
Tributary Width
s
= 4.00ft
Tributary Length
1
= 2.83 ft
Effective Area
Aft
= 11.30 ft2
Height of Structure
h
= 25 ft
Wind Speed
V
= 95 mph
Exposure Category
D
Building Width
B
= 30 ft
Building Length
L
= 55 It
Zone Width
a
= 3 It
Elevation Height
Z9
= 12 ft
- - Wind Directionality
Kd
= 0.85
- Topography Factor
K,
= 1.00
Ground Elevation Factor
Ka
= 1.00
Velocity Pressure Exposure Coefficient
K.
= 1.13
- Velocity Pressure
q,=0.00256K�KnKdKftV2
= 22.10 psf
_- .SolarArray Pressure Equalization
Y.
= 0.79
Array Edge Factor
YE
= 1.50
Zone
GCp
p = q=(GC )1
3
- - -
3r
3.57
-94.11
- -
3e
2.99
-78.71
2
2r
2.99
-78.71
2e
-
-
- _
2n
2.99
-78.71
1
1'
war.,rb
$-r1--+�I--w-
.. �+m��.w,awuma �.r,a�rrww.bea�uaan,mr
e.wO4apsRIXmpnm 4nm.W.,e.krrm.
Ed��. dwHblmr.
r I
I � _
.wn.
E Rw°m,rmeymerafr�mnewu�a l.`Rldl
4. W nLLm u�� ,�pyuuwW rw�N W aOlrwrYwlm.nRn4m.
. e�"arr�.,r.Aa°rwro�a,ixixn�•.•.mm4.4°rwmeu °,w.aw...m.a
.m.au�.°. w,e�m.wc°.mawe Wwamemmc
W
, ro rood
EftwIWe and Am,A,m
PtlIRES9M8Wr VWI VAr,u, EpoRv,br fl[brr.. MCrtbeG W gMf[y EMObO CYgyr OrpRMdjIN
Loads
Wind Pressures
q.
_ -78.71 psf
Tributary Length
I
= 2.83 It
Attachment Spacing
w
= 4.00 ft
Tributary Area
At
= 11.3 ft'
Solar Panel Load
Qo
= 3 psf
Wind Load
Pw = q, * At
_ -889 Ibs
Dead Load
Po = QD * At
= 33.9 Ibs
Uplift
Pa 0.6 + P.
_ -513 lbs
Clamp Ultimate Load
P
= 1819 Ibs (ICC 1976)
Factor of Safety
W
= 3
Allowable Withdrawal per Attachment
Ta = T * ns
= 606.3 Ibs
Demand Capacity Ratio
DCR = Pa / Te
= 0.85 < 1 OK
EISMIC WEIGHT COMPARISON / ANALYSIS .(PER CEBC 2019 Part 10 Chapter 5 Section 502.51
w
Module Model
Panel Weight
Number of Panels
Total PV System Weight
Panasonic
Wpanel
NPv
WPV = Wpanel * NPV
43 lbs
24
= 1032 Ibs
Roof Weight
Qp
= 5.0 psf
Building Length
Lbeild
= 55 ft
- Building Width
Wbuild
= 30 ft
Roof Area
AbOd
1650 fe
.... Building Perimeter
Pbuild
= 170 ft
_— Wall Height
h,
= 8 it
Wall weight
Qwall
= 15 psf
- -- Interiorwallweight
Qint
= 10 psf
= Roof Load
Wnoor = Abuild * Qo
= 8250 Ibs
- -- -- Wall Load Nwall
= hl /2 * Qwall * Pbulld � Abuiw *
Clint /: = 18450 Ibs
- - -.�LTotal Story Weight
Wbuild = Wnoor+ Wwall
= 26700 Ibs
Percentage Weight Increase
WPV / Wbuid
= 3.87% < 10% OKAY