Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
X2021-3034 - Misc (2)
Project Name & Address PpRT C ��P Report �of Sp cW lnspec,flon� InspectionType(s) L5o4Ith G/ Inspection Date(s)X ] Periodic ( ] Continuous Describe Inspection lMade, including Locations: Ohs dieC d apy / n � � d List Tests Made: o & �a� ,q 4L0 /-t�Lb.�� A"/ Total Inspection'rime Each Day: Date O -22-22 Hours List Items Requiring Correction, include uncorrected items previously listed Comments: To the best of my knowledge, the work inspected was in accordance with the Building Department approved design drawings, specifications and applicable workmanship provisions of the U.B.C. except as noted above. Signed: Date Date 01-22—ZoLZ..// Print Full Name: 70 ` �0 !� e L &14 G" Registration No. 02-1,3 FORM SI -02,90 0 X, C FISHER INSPECTION SERVICES CONSTRUCTION INSPECTION AND TESTING 19380 RINALDI STREET, #350 - NORTHRIDGE, CA 91328 OIHce: 818.349.1808 , Fax: 818-349.2340 DepL of Bid. & Safety nil I MI lCu INSPECTOR'S DAILY REPORT cly bl Job No. Date TYPE OF O Reinforced Concrete 0 Structural Steel Assembly U Quality Control INSPECTION O Post Tensioned Concrete ❑ Fire Proofing 0 Other REQUIRED ❑ Reinforced Masonry CityJob Name tC7 Type of StrucWro fi S' a Material Description (type, grade, source)Inspectors) Job Address {{�NLICENSE#WELDER Name LtorWELDER LDER LICENSE # INSPECTION SUMMARY— LOCATIONS OF WORK INSPECTED, TEST SAMPLES TAKEN, WORK REJECTED, JOB PROBLEMS, PROGRESS, REMARKS, ETC. INCLUDES INFORMATION ABOUT AMOUNTS OF MATERIAL PLACED OR WORK PERFORMED, NUMBER, TYPE & IDENT.. NO'S OFTEST SAMPLES TAKEN, STRUCT. CONNECTIONS 0��2 —L02 (WELD MADE H.T. BOLTS TORQUED) CHECKED, ETC. 31 aedcholz AoZ h /" ,` . r� W I r� ©r L o /� ' al4 c4 d F Gt T cent rr✓ e c I LI e ct� �t/�/ -- L - != 1b, 1 r'-[UCrJ41 �L eS rS Co Ge c CERTIFICATION OF COMPLIANCE CONTINUED ON NEXT PAGE ❑ PAGE __ OF 1 HEREBY CERTIFY THAT i HAVE INSPECTED TO THE BEST OK MY KNOWLEDGE 7AppmvedBy TIME OUT REG. HOURS O.T. HOURS TEST S. ALL OF THE ABOVE REPORTED WORK UNLESS OTHERWISE NOTED. I HAVE FOUND THIS WORKTOCOMPLYWITHT IE APPROVED PLANS,SPECIFICATIONS, ANDAPPLICABLE 71 NSOFTH NING BUILDING LAWS.s based on a minimum of 4 hours and over 4 hours — S hour addition, any Inspection nand asl noon hour will 6e en B SIG TUR /O�FJI±EGISTERED INSPE TOR .�' _s"" EoG/ SPECIALTY- NO. AGENCY Fisher Form V1 1112o10 / Prolaet Superintendent Compliance Results: COMPLIES Enforcement Agency Use: Checked by/Date SHUT-OFF LIGHTING CONTROL ACCEPTANCE DOCUMENT Intent: This document is used to demonstrate compliance with acceptance requirements In 9130.4(a)4 and Reference Nonresidential Appendix NA7.6.2 for shut-off lighting controls. Attach additional sets of pages 1 through 2, as required, for all controls that must be tested. Indicate all types of shut-off controls tested for this project: 1 Or Automatic time switch lighting controls (Sections A-1 and B-1 of this document should be completed) Occupant sensing lighting controls (including occupant sensors, partial -ON occupant sensors, partial -OFF occupant sensors, and/or vacancy sensors) (Sections A-2 and B-2 of this document should be completed) A-1. Automatic Time Switch Lighting Control Construction Inspection (NA7.6.2.4) ff a. Automatic time switch controls are programmed with acceptable weekday, weekend, and holiday (If applicable) schedules. (NA7.6.2.4(a), §110.9(b)IAii, §130.1(c)1A, §130.1(c)4) IF b. Document for the owner weekday, weekend, and holidays schedules, as well as all set-up and preference program settings. (NA7.6.2.4(b)) W, C. The correct time and date are properly set in the time switch. (NA7.6.2.4(c)) d. The battery backup (if applicable) is installed and energized. (NA7.6.2.4(d), §110.9(b)i) e. Override time limit is no more than 2 hours. (NA7.6.2.4(e), §110.9(b)1AI, §130.1(c)3B) OR The automatic time switch control's override time Is exempt from the 2: hour limit. (EXCEPTION to §130.1(c)3B) ff f. Override switches remote from area with controlled luminaires have annunciator lights. (NA7.6.2.4(f), §130.1(c)3A, §130.1(a)) OR The manual override switch is exempt from being in the same enclosed area with the lighting it controls. (EXCEPTION 1 to §130.1(a)2) Construction Inspection Compliance: 0 Complies 4 Does Not Comply CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance This is page 1 of 5 B-1. Automatic Time Switch Lighting Control Functional Testing (NA7.6.2.5) Confirm compliance (Y - yes / N - no) for the control being tested. Building: 1 Floor: 1 Roam: Sales 101 Control: Automatic Time Switch Step 1: Simulate Occupied Condition. (NA7.6.2.5(a)) a. All lights can be turned on and off by their respective area control switch. (NA7.6,2.5(a)1) b. The switch only operates lighting in the enclosed space (ceiling -height partitioned area) in which the switch is located. (NA7.6.2.5(a)2, §130.1(c)1C) c. For the area controlled by an automatic time switch control with a time override located in and for the area, the lighting can be turned on manually by Initiating the time override, The lighting is configured to remain on for no more than 2 hours, unless the area is exempt from the 2 -hour time override limit. (NA7.6.2.5(a)3, §110.9(b)1Ai, §130.1(c)3B, EXCEPTION to §130.1(c)3B) d. For the area controlled by an automatic time switch control with an automatic holiday shut-off feature, the lighting in the area can be turned off automatically by initiating the holiday shut-off. (NA7.6.2.5(a)4, §110.9(b)1Aii, §130.1(c)4) OR The automatic time switch control is exempt from Incorporating an automatic holiday shut-off feature. (EXCEPTION to §130.1(c)4) e. For the area controlled by an automatic time switch control with manual -on mode configured, the lighting in the area can be turned on manually when It is manually activated, (NAT6.2.5(a)5, §130.1(c)1E) OR The automatic time switch control does not include or utilize a manual -on mode. (§130.1(c)1E) Step 2: Simulate unoccupied condition. (NA7.6.2.5(b)) a. All non-exempt lighting turns off in accordance with the programmed time switch schedules. (NA7.6.2.5(b)1, §130.1(c)IA) OF b. Manual override switch allows only the lights in the enclosed space (ceiling height partitioned) where the override switch is located to turn on or remain on until the next scheduled shut off occurs. (NA7.6.2.5(b)2, §130,1(c)iC, §130.1(c)3) Functional Testing Compliance: Complies Of Does Not Comply IMM111W CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance This is page 2 of 5 A-2. Occupant Sensing Lighting Control Construction Inspection (NA7.6.2.2)) ff a. Occupant sensors have been located to minimize false signals. (NA7.6.2.2(a)) b. Occupant sensors are located no closer than four (4) feet from any HVAC diffuser. (NA7.6.2.2(b)) c. Passive Infrared sensor pattern does not enter into adjacent zones. (NA7.6.2.2(c)) PW d. Occupant sensors do not encounter any obstructions that could adversely affect desired performance. (NA7.6.2,2(d)) W e. Ultrasonic occupant sensors do not emit audible sound. (NA7.6.2.2(e), §110.9(b)613H) Construction Inspection Compliance: 0. Complies O Does Not Comply B-2. Occupant Sensing Lighting Control Functional Testing (NA7.6.2.3) Confirm compliance (Y - yes / N - no) for the control being tested. [_Building: 1 Floor: 1 Room: Office 109 Control: Occupancy Sensor is Control is representative of sample. (NA7.6.2.3) If sampling method Is used, attach a page listing untested controls In sample. Step 1: Simulate an unoccupied condition. (NA7.6.23(a)) a. Lights controlled by occupant sensing control turn off or partially off, If applicable, within a maximum of 20 minutes from start of an unoccupied condition. (NA7.6.23(a)i, §110.9(b)4A) In the partial off state, partial -OFF occupant sensors automatically reduce lighting power by at least 50% (§130.1(c)6A-C, §130.1(c)7A), OR., • For metal halide or high pressure sodium lighting in warehouses, automatically reduce lighting power by at least 40% (EXCEPTION 2 to §130.1(c)6A). • In aisle ways and open areas In warehouses in which the installed lighting power is 80% or less of the value allowed under the Area Category Method, automatically reduce lighting power by at least 40% (EXCEPTION 1 to §130.1(c)6A). • In corridors and stairwells in which the installed lighting power Is 80% or less of the value allowed under the Area Category Method, automatically reduce lighting power by at least 40% (EXCEPTION to §130.1(c)7A). Occupant sensing controls in parking garages, parking areas, and loading and unloading areas have at least one control step between 20 to 50% of design lighting power (§130.1(()78). OR Occupant sensing controls for metal halide luminaires with a lamp plus ballast mean system efficacy of 75 lumens per watt in parking garages, parking areas, and loading and unloading areas have at least one control step between 20 to 60% of design lighting power (EXCEPTION to §130.1(()76). b. The occupant sensing control does not trigger a false "on" from movement in an area adjacent to the controlled space or from HVAC operation. (NA7.6.2.3(a)2) c. Signal sensitivity is adequate to achieve desired control. (NA7.6.2.3(a)3) For library book stacks or warehouse aisles, activity beyond the stack or aisle shall not activate the lighting in the stack or aisle, (§130.1(c)6A, §130.1(()66) Step 2: Simulate an occupied condition. (NA7.6.2.3(b)) a. Status Indicator or annunciator operates correctly. (NA7.6.2.3(b)1, §110.9(15)4C) b. Immediately upon an occupied condition (NA7.6.2.3(b)2): • Lights controlled by an occupant sensor or a partial -OFF occupant sensor turn on; OR: • A vacancy sensor indicates a space is 'occupied" and lights may be turned on manually; OR: • The first stage of a partial -ON occupant sensor automatically activates between 50 to 70% of the lighting. (§130.1(c)SA)OR: After the first stage occurs for partial -ON occupant sensors, manual switches allow an occupant to activate the alternate set of lights, activate 100% of the lighting power, and manually deactivate all of the lights. Functional Testing Compliance: CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance This is page 3 of 5 Complies 0 Does Not Comply Building: 1 Floor: 1 Room: Stock Room 105 Control: Occupancy Sensor 1W I Control Is representative of sample. (NA7.6.2.3) If sampling method is used, attach a page listing untested controls in sample. Step 1: Simulate an unoccupied condition. (NA7.6.2.3(a)) a. Lights controlled by occupant sensing control turn off or partially off, if applicable, within a maximum of 20 minutes from start of Fill an unoccupied condition. (NA7.6.2.3(a)l, §110.9(b)4A) In the partial off state, partial -OFF occupant sensors automatically reduce lighting power by at least 50% (§130.1(C)6A-C, §130.1(c)7A), OR: • For metal halide or high pressure sodium lighting in warehouses, automatically reduce lighting power by at least 40% (EXCEPTION 2 to §130.1(c)6A). • In aisle ways and open areas in warehouses in which the installed lighting power is 80% or less of the value allowed under the Area Category Method, automatically reduce lighting power by at least 40% (EXCEPTION I to §130.1(c)6A). • In corridors and stairwells in which the installed lighting power is 80% or less of the value allowed under the Area Category Method, automatically reduce lighting power by at least 40% (EXCEPTION to §130.1(c)7A). Occupant sensing controls in parking garages, parking areas, and loading and unloading areas have at least one control step between 20 to 50% of design lighting power (§130.1(c)7B). OR Occupant sensing controls for metal halide luminaires with a lamp plus ballast mean system efficacy of 75 lumens per watt in parking garages, parking areas, and loading and unloading areas have at least one control step between 20 to 60% of design lighting power (EXCEPTION to §130.1((}7B). b. The occupant sensing control does not trigger a false 'on" from movement in an area adjacent to the controlled space or from HVAC operation. (NA7.6.2,3(a)2) c. Signal sensitivity is adequate to achieve desired control. (NA7.6.2.3(a)3) For library book stacks or warehouse aisles, activity beyond the stack or aisle shall not activate the lighting In the stack or aisle. (§130.1(c)6A, §130.1(c)6B) Step 2: Simulate an occupied condition. (NA7.6.2.3(b)) a. Status indicator or annunciator operates correctly. (NA7,6.2.3(b)1, §110.9(b)4C) b. Immediately upon an occupied condition (NA7.6.2.3(b)2): • Lights controlled by an occupant sensor or a partial -OFF occupant sensor turn on; OR: • A vacancy sensor indicates a space is 'occupied" and lights may be turned on manually; OR: - • The first stage of a partial -ON occupant sensor automatically activates between 50 to 70% of the lighting. (§130.1(c)5A)OR: After the first stage occurs for partial -ON occupant sensors, manual switches allow an occupant to activate the alternate set of lights, activate 100% of the lighting power, and manually deactivate all of the lights. Functional Testing Compliance: Complies 0 Does Not Comply INNIMMCA Building Energy Efficiency Standards - 2019 Nonresidential Compliance This is page 4 of 5 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT I certify that this Certificate of Acceptance documentation Is accurate and complete. Documentation Author Gary Logan Company Name Name Address 6285 E. Spring St. Suite 591 City/State/"Lip Phone CEA/ATT Certification (562)858-1595 Identification (if applicable) Author Signature Date of Signature: 05/03/2022 Perception industries, Inc. Long Beach, CA 90808 TC-AS13655 FIELD TECHNICIAN'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. The Information provided on this Certificate of Acceptance Is true and correct. 7.. I am the person who performed the acceptance verification reported on this Certificate of Acceptance (Field Technician), 3. The construction or installation Identified on this Certificate of Acceptance complies with the applicable acceptance requirements Indicated in the plans and specifications approved by the enforcement agency, and conforms to the applicable acceptance requirements and procedures specified in Reference Nonresidential Appendix NA7. 4. 1 have confirmed that the Certificate(s) of Installation for the construction or installation identified on this Certificate of Acceptance has been completed and signed by the responsible builder/Installer and has been posted or made available with the building permits) Issued for the building, Field 'Technician Name Company Name Gary Loyan Perception Industries, Inc. Address: 6285 E. Spring St. Suite 591 City/State/zip Long Beach, CA 90808 Phone (5fi2)BSB-SSgS ATT Certification IC-ABi36B5 Identification Position with Company Field Technician Signature (Title) Vice President 7 Date of Signature: 05/03/2022 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1, I am the Field Technician, or the Field Technician is acting on my behalf as my employee or my agent and I have reviewed the information provided on this Certificate of Acceptance. 2. t am eligible under Division 3 of the Business and Professions Code In the applicable classification to accept responsibility for the system design, construction or installation of features, materials, components, or manufactured devices for the scope of work Identified on this Certificate of Acceptance and attest to the declarations In this statement (responsible acceptance person). 3. The information provided on this Certificate of Acceptance substantiates that the construction or installation Identified on this Certificate of Acceptance complies with the acceptance requirements Indicated in the plans and specifications approved by the enforcement agency, and conforms to the applicable acceptance requirements and procedures specified In Reference Nonresidential Appendix NA7. 4. I have confirmed that the Certificates) of Installation for the construction or installation identified on this Certificate of Acceptance ties been completed and Is Posted or made available with the building permit(s) Issued for the building. 5. I will ensure that a completed, signed copy of this Certificate of Acceptance shall be posted, or made available with the building permit(s) Issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a signed copy of this Certificate of Acceptance is required to be Included with the documentation the builder provides to the holding owner at occupancy. Responsible Acceptance Gar Logan Company Name Person Name y 9 Perception Industries, Inc. Address: 6255 E. Spring St. Suite 591 City/State/Zip Long Beach, CA 90808 Phone CSLB License (562)858-1595 1017642 Position with Company Responsible Acceptance Person Signature (Title) Vire President Date of Signature: 05/03/2022 CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance This is page 5 of 5 T lfdh� -vsf CERTIFIED TEST, ADJUST, AND BALANCE REPORT DATE April 29, 2022 PROJECT Allbirds - Fashion Island ADDRESS 1125 Newport Center Dr. Newport Beach CA 92660 ARCHITECT -. ' N/L ADDRESS N/L PHONE/FAX N/L ENGINEER HENDERSON ENGINEERS, INC. ADDRESS 8345 LENEXA DRIVE SUITE 300 1 -.PHONE/FAX ENEXA, KS 66214 HVAC CONTRACTOR J.R. STEVENS MECHANICAL ADDRESS 720 MONROE WAY PLACENTIA, CA 92870 PHONE/FAX 714-890-0952 TAB FIRM HARTMANAIRE ADDRESS 12 GARDENA LAKE FOREST, CA 92630 PHONE/FAX 951-479-6855 / 949-215-1001 Cindy McClanahan McClanahan Inc DBA HaNmanai,e TA90 Canl2dor ATB9696617C Not Vidd Unless SgneC L CERTIFICATION PROJECT ALLBIRDS ADDRESS 1125 NEWPORT CENTER DRIVE NEWPORT REACH CA 99660 THE DATA PRESENTED IN THIS REPORT IS AN EXACT RECORD OF SYSTEM PERFORMANCE AND WAS OBTAINED IN ACCORDANCE WITH TABB - ICB STANDARD PROCEDURES. ANY VARIANCES FROM DESIGN QUANTITIES WHICH EXCEED TABB TOLERANCES ARE NOTED THROUGHOUT THIS REPORT. THE AIR DISTRIBUTION SYSTEMS HAVE BEEN TESTED & BALANCED AND FINAL ADJUSTMENTS HAVE BEEN MADE IN ACCORDANCE WITH TABB - ICB PROCEDURAL STANDARDS FOR TESTING, ADJUSTING BALANCING OF ENVIRONMENTAL SYSTEMS AND THE PROJECT SPECIFICATIONS. TABB TAB FIRM REG. NO. TBO690817C CERTIFIED BY Mario Covarrubias DATE 4/29/2022 (Air Tab Supervisor) THE HYDRONIC DISTRIBUTION SYSTEMS HAVE BEEN TESTED & BALANCED AND FINAL ADJUSTMENTS HAVE BEEN MADE IN ACCORDANCE WITH TABB - ICB PROCEDURAL STANDARDS FOR TESTING, ADJUSTING BALANCING OF ENVIRONMENTAL SYSTEMS AND THE PROJECT SPECIFICATIONS. TABB TAB FIRM REG. NO. TB0690817C CERTIFIED BY DATE (Hydronic Tab Supervisor) cg%Certifi°a! SUBMITTED & CERTIFIED BY: ti c / TABB TAB FIRM HARTMANA/RE TAB SUPERVISOR Mario Covarrubias""�� Marlo Covarrublas McClanahan lnc. CBA Hadmanai. SIGNATURE ,,.yrw..ao. •°w'a.�. �--,,. T#M97e�'/5s' 444 s,w,..os�orsoxa / 1 TABLE OF CONTENTS SECTION I - PROJECT INFORMATION CERTIFICATES 1 WARRANTY 5 CALIBRATION g ABBREVIATIONS 7 SECTION II - UNIT REPORTS UNIT REPORT g -g IN/OUT REPORT 10 SECTION III -OTHER DATA MECHANICAL PLAN 11 3" 400 A I 1 \`I 17 IN 1IN IQ O N zo w °z0 a! z 0 6 a aF w I 1 \`I 17 IN 1IN IQ O N 9 tl� v., NO 1 I M R 91 I O ' N I�4 .4 L4 .'d M m zo N 2Q Q y Z fW/I �O a� tl� v., NO 1 I M R 91 I O ' N I�4 .4 L4 .'d M A a ►7 c .. O N O N N O N �i V Q > 13 x I m va 0 g N V F, W d' OU y d c 0 IL S OIR w � 0 F m ad N � V V O � .0 O V � m � N U O � � N 1-i OIR 0 N � N N T 5k e 0 IL go o.2 N Cq aWr OU T d c N a U 'a m z_u zo U= ZV mei zo W OW Z LL NO �a a� i u� F .i 00 ax E 19 Q 9 m � F �� aq � � V p � p V s V v o m 0 00 ax E 19 Q 9 12 Gardenia Lake Forest, CA 92630 951-479-6885 Warranty lUll' 30iq Warranty of Services Hartmanaire warranties the TAB work for one year from the date of this report. Hartmanaire reserves the right to correct errors or omissions in the collection of data. The Warranty covers Balancing Issues. Off Season Testing: Typical balance report covers testing and balancing of all scheduled equipment, regardless of the outside air temperature. An Off Season test will generally cover temperature measurements Balancing Issues: Any balancing issues or concerns that arise, Hartmanaire will return to the site any time during the warranty period. Systems will be rechecked and verified that tested items adhere with the reported test date, AT NO CHARGE. Warranty Procedures For all warranty items Balancing Issues, Hartmanaire requires a written request. The written request should be specific on the areas of concern, such rooms, or equipment, and the type of issue the occupants are having. Once written notification is received Hartmanaire will schedule a Technician. It is recommended that an Owner, or Architect, or Engineer be on site at that time. Voided Warranty and Additional Charges If a complaint issue is due to a mechanical equipment failure, control or maintenance related, the return trip maybe subject to a service charge, not covered under warranty. Hartmanaire reserves the right to resolve any TAB issues. If a third party or competing Test & Balance/Commissioning firm test or adjust any equipment, all project warranty is voided. (This is typical standard for the Mechanical industry, as Manufacture, Mechanical and Control Contractor voids all warranty when a competing firm test or manipulates their systems.) Any return trip to the job site is subject to a service charge and a purchase order will be required before returning to the job site. Document Archiving An electric file of all test documents will be kept on file until the end of the Warranty period. During that time an electronic copy of the test date will be provided a no charge. Any additional hard bound copies requested will be subject to a fee. Building owner should retain all documentation for future reference. All documentation pertaining to this project will be destroyed in accordance with our record retention schedule. g N A fi -P g! f N 0 a 0 a' 0 02 2 U. Is, + z ON I gL I�,i 61, _s; Isis, z 0 E E N EE 0 0 0 0 E LD 0 13 ws E, 2, 0 0 79 39 3 w �U S �E M w I's yy is L D E: 0 0 E Is 12 I's Pa r E E s:K Is, J., to Z �c 2 12 'o e e e I's sss, z EI E "so E 0 N go Is' I's E E E :s z 0E E E E 0 z p, E 0 E E o 0 12 Gardenia Lake Forest, CA 92630 951-479-6885 ABBREVIATIONS ACT - Actual AK - Free Area Factor AHU - Air Handling Unit CD - Ceiling Diffuser CER - Ceiling Exhaust Register CFM - Cubic Feet per Minute CR - Ceiling Return Register D.B. - Dry Bulb DD - Direct Drive DDC - Direct Digital Controls: EMS Control System for the HVAC DL - Drum Louver DNL - Data Not Listed EF Exhaust Fan EMS - Energy Management System ERU - Energy Recovery Unit ENT - Entering FH - Flowhood (Measures CFM Directly SO FPM and AK factors are not required). FPM - Feet per Minute GPM - Gallons per Minute H.P. - Horsepower LVG - Leaving MBH - 1,000 BTUH NA - Not Available / No Access NVL - No Valid Location O.S.A. - Outside Air P.D. - Pressure Drop R.A. - Return Air REQ - Required RPM - Revolutions per Minute RTU - Roof Top Unit S.A. - Supply Air S.F. - Service Factor S.P. - Static Pressure SWS - Side Wall Supply SWR - Side Wall Return TAB - Test, Adjust, and Balance TSP - Total Static Pressure Traverse - CFM readings take in at a point in the ductwork VAV - Variable Air Volume; box that contains a motorized damper that modulates airflow W.B. - Wet Bulb W.G. - Water Gauge PACKAGE ROOFTOP / HEATPUMP / AC UNIT REPORT PROJECT Allbirds Fashion Island Date 4/29/2022 LOCATION 1125 Newport Center Dr Newport Beach, CA 92660 FAN NAME SERVICE LOCATION MANUFACTURER MODEL NUMBER SERIAL NUMBER CFM TOTALFAN RETURN AIR OUTSIDE AIR DAMPER POS.OSA% STATIC PRESSURES FAN MOTOR VOLTAGE PHASE SPEED(RPM) SERVICE FACTOR DRIVE MOTOR SHEAVE SIZE % CLOSED FAN SHEAVE SIZE FAN, RPM BELT SIZE / # OF CENTER LINE NOTES: RTU -1 Sales Roof Carrier CQD12A2F5AOA 1613G30203 Stock/Break/Fitting Roof Carrier 50TCQA07A3F5AOA DESIGN ACTUAL DESIGN ACTUAL DESIGN 4250 4415 1500 1480 3750 3905 1060 1025 500 510 440 455 0.79" 0.22" 1.25" 1.01" Marathon 3.9bhp 208 201/201/20; 10.6 7.2/7.4/7.8 3 1725 1739 1.15 1 VL44 x 7/8" 50% AFD74 x 1" DNL 1 1025 AX49-1 17" 0.54" 0.21" 0.80" 0.75' Marathon 2.9bhp 208 202/202/20: 8.4 5.8/6.0/6.2 3 1725 1733 1.15 1VL40 x 7/8" 20% AFD44 x 5/8" DNL 1568 AX49-1 ACTUAL M PROJECT Allbirds Fashion Island INOUT REPORT AREA NO. KIND SIZE AK DESIGN PRELIM FINAL REMARKS RTU -1 SA Sales 101 1 LD 48" x 1" 1.00 240 235 Sales 101 2 LD 48" x 1" 1.00 240 240 Sales 101 3 LD 48" x 1" 1.00 240 230 Sales 101 4 LD 48" x 1" 1.00 240 250 Sales 101 5 LD 48" x 1" 1.00 300 310 Sales 101 6 LD 48" x 1" 1.00 340 365 Sales 101 7 LD 48" x 1" 1.00 340 370 Sales 101 8 LD 48" x 1" 1.00 340 360 Sales 101 9 LD 24" x 1" 1.00 150 160 Sales 101 10 LD 24" x 1" 1.00 150 165 Sales 101 11 LD 24" x 1" 1.00 150 150 Sales 101 12 LD 48" x 1" 1.00 240 265 Sales 101 13 LD 24" x 1" 1.00 160 175 Sales 101 14 LD 48" x 1" 1.00 240 260 Sales 101 15 LD 24" x 1" 1.00 160 165 Sales 101 16 LD 24" x 1" 1.00 160 160 Sales 101 17 LD 48" x 1" 1.00 240 255 Sales 101 18 LD 24" x 1" 1.00 160 150 Sales 101 19 LD 24" x 1" 1.00 160 150 4250 4415 RA Stockroom 105 1 SO 34" x 10" 2.36 3750 3905 1654fpm REMARKS Fowl PROJECT Allbirds Fashion Island IVII )AI INOUT REPORT AREA NO. KIND SIZE AK DESIGN PRELIM FINAL REMARKS RTU -2 SA Break Area 106 1 SG 8" x 6" 1.00 150 145 Break Area 106 2 SG 8" x 6" 1.00 150 150 Stockroom 105 3 SG Tx 6" 1.00 150 140 Stockroom 105 4 SG 8" x 6" 1.00 150 140 Restroom 108 5 CD 2406 1.00 50 55 Office 107 6 CD 2406 1.00 100 95 Stockroom 105 7 SG 8" x 6" 1.00 150 160 Sales 101 8 LD 48" x 1" 1.00 200 200 Sales 101 9 LD 48" x 1" 1.00 200 200 Fitting #3 104 10 LD 24" x 1" 1.00 50 45 Fitting #2 103 11 LD 24" x 1" 1.00 50 45 Fitting #1 102 12 LD 24" x 1" 1.00 50 50 Show Window 111 13 LD 24" x 1" 1.00 50 55 1500 1480 RA Stockroom 105 1 SO 18" x 12" 1.50 1060 1025 684fpm EF -1 EA Restroom 108 1 EG 10" x 10" 1.00 100 110 EF -2 EA Janitor 110 1 EG 10" x 10" 1.00 75 85 REMARKS * Ceiling Mounted. Direct Drive. Single Speed.