HomeMy WebLinkAboutPA2022-067_20220404_pWQMP_03-21-22County of Orange/Santa Ana Region Priority Project PRELIMINARY Water Quality Management Plan (pWQMP) Project Name: OCEAN FRONT POOL HOUSE Grading Permit Number 1616 W. OCEANFRONT Newport Beach, CA 92663 Lot 8, BLOCK 16, SECTION B 047-202-23 Prepared for: SMITH 507, LLC 1616 W. OCEANFRONT NEWPORT BEACH, CA 92663 Prepared by: TOAL ENGINEERING, INC. 139 AVENIDA NAVARRO SAN CLEMENTE, CA 92672 (949) 492-8586 CALEB RIOS, RCE RCE#57587 CRIOS@TOALENGINEERING.COM DATE PREPARED: 03/21/2022 PA2022-067 Priority Project Water Quality Management Plan (WQMP) Project: OCEAN FRONT POOL HOUSE Owner: SMITH 507, LLC Owner’s Certification JN: 21212 Page i This Water Quality Management Plan (WQMP) has been prepared for SMITH 507, LLC by Toal Engineering, Inc.. The WQMP is intended to comply with the requirements of the County of Orange NPDES Stormwater Program requiring the preparation of the plan. The undersigned, while it owns the subject property, is responsible for the implementation of the provisions of this plan , including the ongoing operation and maintenance of all best management practices (BMPs), and will ensure that this plan is amended as appropriate to reflect up-to-date conditions on the site consistent with the current Orange County Drainage Area Management Plan (DAMP) and the intent of the non-point source NPDES Permit for Waste Discharge Requirements for the County of Orange, Orange County Flood Control District and the incorporated Cities of Orange County within the Santa Ana Region. Once the undersigned transfers its interest in the property, its successors-in-interest shall bear the aforementioned responsibility to implement and amend the WQMP. An appropriate number of approved and signed copies of this document shall be available on the subject site in perpetuity. Owner: Title SMITH 507, LLC Company SMITH 507, LLC Address 1616 W. OCEANFRONT, NEWPORT BEACH, CA 92663 Email OWNER EMAIL Telephone # N/A I understand my responsibility to implement the provisions of this WQMP including the ongoing operation and maintenance of the best management practices (BMPs) described herein. Owner Signature Date Project Owner’s Certification Planning Application No. (If applicable) TBD Grading Permit No. TBD Tract/Parcel Map and Lot(s) No. Lot 8, BLOCK 16, SECTION B Building Permit No. TBD Address of Project Site and APN (If no address, specify Tract/Parcel Map and Lot Numbers) 1616 W. OCEANFRONT Newport Beach, CA 92663 Lot 8, BLOCK 16, SECTION B PA2022-067 Priority Project Water Quality Management Plan (WQMP) Project: OCEAN FRONT POOL HOUSE Owner: SMITH 507, LLC Owner’s Certification JN: 21212 Page ii Preparer (Engineer): Title CALEB RIOS PE Registration # RCE#57587 Company TOAL ENGINEERING, INC. Address 139 AVENIDA NAVARRO, SAN CLEMENTE, CA 92672 Email CRIOS@TOALENGINEERING.COM Telephone # 949-492-8586 I hereby certify that this Water Quality Management Plan is in compliance with, and meets the requirements set forth in, Order No. R8-2009-0030/NPDES No. CAS618030, of the Santa Ana Regional Water Quality Control Board. Preparer Signature Date Place Stamp Here PA2022-067 Priority Project Water Quality Management Plan (WQMP) Project: OCEAN FRONT POOL HOUSE Owner: SMITH 507, LLC Table of Contents JN: 21212 Page iii Contents Page No. Section I Permit(s) and Water Quality Conditions of Approval or Issuance ........... 1 Section II Project Description .................................................................................. 3 Section III Site Description ....................................................................................... 8 Section IV Best Management Practices (BMPs) ...................................................... 10 Section V Inspection/Maintenance Responsibility for BMPs ................................. 24 Section VI BMP Exhibit (Site Plan) ......................................................................... 25 Section VII Educational Materials ............................................................................ 26 Attachments Attachment A . ................................................................................. Educational Materials Attachment B . ............................................................. BMP Fact Sheets and Calculations Attachment C . ................................................................................. Educational Materials Attachment D . ................................................................. Operations & Maintenance Plan Attachment E . ................................................................................. Geotechnical Reports PA2022-067 Priority Project Water Quality Management Plan (WQMP) Project: OCEAN FRONT POOL HOUSE Owner: SMITH 507, LLC Section I JN: 21212 Page 1 Section I Permit(s) and Water Quality Conditions of Approval or Issuance Provide discretionary or grading/building permit information and water quality conditions of approval, or permit issuance, applied to the project. If conditions are unknown, please request applicable conditions from staff. Project Infomation Permit/Application No. (If applicable) TBD Grading or Building Permit No. (If applicable) TBD Address of Project Site (or Tract Map and Lot Number if no address) and APN 1616 W. OCEANFRONT NEWPORT BEACH, CA 92663 Lot 8, BLOCK 16, SECTION B Water Quality Conditions of Approval or Issuance Water Quality Conditions of Approval or Issuance applied to this project. (Please list verbatim.) Conceptual WQMP Was a Conceptual Water Quality Management Plan previously approved for this project? No. Watershed-Based Plan Conditions Provide applicable conditions from watershed - based plans including WIHMPs and TMDLS. Watershed: Newport Bay PA2022-067 Priority Project Water Quality Management Plan (WQMP) Project: OCEAN FRONT POOL HOUSE Owner: SMITH 507, LLC Section II JN: 21212 Page 2 Section II Project Description II.1 Project Description Description of Proposed Project Development Category (From Model WQMP, Table 7.11-2; or -3): 8. All significant redevelopment projects, where significant redevelopment is defined as the addition of 5,000 or more square feet of impervious surface on an already developed site, and the existing development or redevelopment project falls under another Priority Project Category. If the redevelopment results in the addition or replacement of less than 50 percent of the impervious area on-site and the existing development was not subject to WQMP requirement, the numeric sizing criteria discuss below only applies to the addition or replacement area. If the addition or replacement accounts for 50 percent or more of the impervious area, the Project WQMP requirements apply to the entire development. Project Area (ft2): 3,071 Number of Dwelling Units: ____1______ SIC Code: __________ Project Area Pervious Impervious Area (acres or sq ft) Percentage Area (acres or sq ft) Percentage Pre-Project Conditions 3,071 sq ft 100% 0 0% Post-Project Conditions 78 sq ft 2.5 % 2,993 97.4% Drainage Patterns/Connections See Section III.2. Narrative Project Description: (Use as much space as necessary.) The project will demolish and remove existing structures and hardscape and construct a new 3 level residential structure with appurtenant hardscape, utilities, and landscape. PA2022-067 Priority Project Water Quality Management Plan (WQMP) Project: OCEAN FRONT POOL HOUSE Owner: SMITH 507, LLC Section II N JN: 21212 Page 3 II.2 Potential Stormwater Pollutants Pollutants of Concern Pollutant Check One for each: E=Expected to be of concern N=Not Expected to be of concern Additional Information and Comments Suspended-Solid/ Sediment E N From roof and hardscape areas Nutrients E N No proposed landscape areas Heavy Metals E N Not expected for residential development Pathogens (Bacteria/Virus) E N Living organisms Pesticides E N From undesired pest presence Oil and Grease E N Vehicles and other mechanical devices Toxic Organic Compounds E N Not expected for residential development Trash and Debris E N From typical human occupancy II.3 Hydrologic Conditions of Concern Determine if streams located downstream from the project area are potentially susceptible to hydromodification impacts. No – Show map Yes – Describe applicable hydrologic conditions of concern below. Refer to Section 2.2.3 in the Technical Guidance Document (TGD). The subject property is not located in a Potential Area of Erosion, Habitat, & Physical Structure Susceptibility per TGD Figure 4 (Appendix XVI-3). See Figure 4 in Attachment A of this report. PA2022-067 Priority Project Water Quality Management Plan (WQMP) Project: OCEAN FRONT POOL HOUSE Owner: SMITH 507, LLC Section II N JN: 21212 Page 4 II.4 Post Development Drainage Characteristics Post-project runoff is collected in channel drains and downspouts and is conveyed via drain lines to infiltration trenches for water treatment. Overflow of the infiltration trench will outlet through the channel drains and flow into Oceanfront Avenue. II.5 Property Ownership/Management Property Owner: SMITH 507, LLC The property owner, SMITH 507, LLC, will be responsible for the long-term maintenance of the project’s storm water facilities. Maintenance contractors may be hired by the owner to perform operations and maintenance duties. No infrastructure will be transferred to public agencies. PA2022-067 Priority Project Water Quality Management Plan (WQMP) Project: OCEAN FRONT POOL HOUSE Owner: SMITH 507, LLC Section III JN: 21212 Page 5 Section III Site Description III.1 Physical Setting Fill out table with relevant information. Refer to Section 2.3.1 in the Technical Guidance Document (TGD). Name of Planned Community/Planning Area (if applicable) Central Newport Beach Community Association Location/Address 1616 W. OCEANFRONT, Newport Beach, CA 92663 Lot 8, BLOCK 16, SECTION B General Plan Land Use Designation RT – Two Unit Residential Zoning R-2 – Two Unit Residential Acreage of Project Site 3,071 s.f. (0.705 ac) Predominant Soil Type Per the soils report, “The earth materials encountered were classified as artificial fill underlain by native earth materials to the maximum depth explored. Artificial filles encountered consisted of light gray and tan, slightly silty to silty sand, fine grained, dry to damp and loose to medium dense. The fills were encountered to a depth of about two feet below existing grade in the areas explored. Native earth materials encountered consisted of tan and light gray, clean sand, fine grained, damp to wet and generally medium dense, to the maximum depth explored of 12.5 feet.” III.2 Site Characteristics Site Characteristics Precipitation Zone 0.70-inch (TGD Figure XVI-1). See Attachment A. PA2022-067 Priority Project Water Quality Management Plan (WQMP) Project: OCEAN FRONT POOL HOUSE Owner: SMITH 507, LLC Section III JN: 21212 Page 6 Topography The subject property includes a rectangular shaped lot located on Oceanfront Avenue and enclosed by an alleyway on the North and by a residential lots to the east and west. Elevations range from a maximum of about 12.29 at the rear of the property to a minimum of about 9.90 at the frontage along the Alley. The lot is currently a dirt lot with no structures on it, except for the footing of the retaining wall in the north west corner of the lot. Drainage Patterns/Connections Existing drainage patterns/connections Runoff surface flows into the alleyway. The alley center line swale conveys to the curb and gutter of 16th street and then the curb and gutter of Balboa Boulevard. Stormwater in balboa Boulevard is collected in catch basins and conveyed via storm drain pipe and discharged to the Rhine of Newport Harbor which eventually flows to the Pacific Ocean. Proposed drainage patterns/connections Proposed runoff will follow existing patterns. An infiltration trench will be constructed at the rear of the property along Oceanfront Avenue to allow low flows to infiltrate into the ground. Runoff in excess of the infiltration BMP capacity will flow through drain lines and outlet on the east sideyard concrete swale of the property and surface flow to the existing alleyway swale and follow existing patterns of discharge. Soil Type, Geology, and Infiltration Properties Per Hydrologic Soil Group Type D NRCS Soils Survey Map, Figure XVI-2b, The project is located on type D Soils. See Appendix A. Type D soils lend itself to poor infiltration rates Hydrogeologic (Groundwater) Conditions Per North Orange County Mapped Shallow Groundwater Map, TGD Figure XVI-2e, the project site is not located in a depth to groundwater area that is less than or equal to 5’ and it is also not located in an area with a depth to groundwater area that is between 5’-10’. Per the soils report, Groundwater was encountered at 6 feet below existing ground surface during the filed investigation. Geotechnical Conditions (relevant to infiltration) Per the soils report, “ We do not recommend the use of infiltration best management practices (BMP) such as bottomless trench drains, infiltration trenches, infiltration basins, dry wells, permeable pavements or similar systems designed primarily to percolate water into the subsurface soils within five feet of foundations.” A letter of acceptance of the infiltration trench location has been provided in AppendixE. Off-Site Drainage None. PA2022-067 Priority Project Water Quality Management Plan (WQMP) Project: OCEAN FRONT POOL HOUSE Owner: SMITH 507, LLC Section III JN: 21212 Page 7 Utility and Infrastructure Information III.3 Watershed Description Fill out table with relevant information and include information regarding BMP sizing, suitability, and feasibility, as applicable. Refer to Section 2.3.3 in the Technical Guidance Document (TGD). Receiving Waters Newport Bay 303(d) Listed Impairments Lower Newport Bay: Chlordane, Copper, DDT, Indicator Bacteria, Nutrients, PCBs Applicable TMDLs Lower Newport Bay Metals Technical TMDLs Nutrients Implementation Phase Pathogens Implementation Phase Pesticides / Priority Organics Implementation Phase Siltation Implementation Phase Pollutants of Concern for the Project Suspended solids/sediment, nutrients, pathogens, pesticides. Environmentally Sensitive and Special Biological Significant Areas Lower Newport Bay PA2022-067 Priority Project Water Quality Management Plan (WQMP) Project: OCEAN FRONT POOL HOUSE Owner: SMITH 507, LLC Section IV JN: 21212 Page 8 Section IV Best Management Practices (BMPs) IV. 1 Project Performance Criteria (NOC Permit Area only) Is there an approved WIHMP or equivalent for the project area that includes more stringent LID feasibility criteria or if there are opportunities identified for implementing LID on regional or sub-regional basis? YES NO If yes, describe WIHMP feasibility criteria or regional/sub-regional LID opportunities. N/A Project Performance Criteria If HCOC exists, list applicable hydromodification control performance criteria (Section 7.II-2.4.2.2 in MWQMP) If a hydrologic condition of concern (HCOC) exists, priority projects shall implement on-site or regional hydromodification controls such that: • Post-development runoff volume for the two-year frequency storm does not exceed that of the predevelopment condition by more than five percent, and • Time of concentration of post-development runoff for the two-year storm event is not less than that for the predevelopment condition by more than five percent. Where the Project WQMP documents that excess runoff volume from the two-year runoff event cannot feasibly be retained and where in-stream controls cannot be used to otherwise mitigate HCOCs, the project shall implement on-site or regional hydromodification controls to: • Retain the excess volume from the two-year runoff event to the MEP, and Implement on-site or regional hydromodification controls such that the post-development runoff two-year peak flow rate is no greater than 110 percent of the predevelopment runoff two-year peak flow rate. PA2022-067 Priority Project Water Quality Management Plan (WQMP) Project: OCEAN FRONT POOL HOUSE Owner: SMITH 507, LLC Section IV JN: 21212 Page 9 List applicable LID performance criteria (Section 7.II-2.4.3 from MWQMP) • Priority Projects must infiltrate, harvest and use, evapotranspirate, or biotreat/biofilter, the 85th percentile, 24-hour storm event (Design Capture Volume). List applicable treatment control BMP performance criteria (Section 7.II-3.2.2 from MWQMP) • If treatment control BMPs can treat all of the remaining unmet volume and have a medium to high effectiveness for reducing the primary POCs, the project is considered to be in compliance. • If the cost of providing treatment control BMPs greatly outweighs the pollution control benefits they would provide, a waiver of treatment control and LID requirements can be requested, and alternative compliance approaches must be used to fulfill the remaining unmet volume. Calculate LID design storm capture volume for Project. Simple Method per TGD III.1.1. DCV=C ×d ×A C= (0.75 ×imp+0.15) = 0.75 ×9.74+0.15=0.88 d= 0.70 in. A= 3,071 sq.ft. DCV=0.88 x 0.70 in.x 3,071 s.f. x ((1 ft.)/(12 in.))=157 cf PA2022-067 Priority Project Water Quality Management Plan (WQMP) Project: OCEAN FRONT POOL HOUSE Owner: SMITH 507, LLC Section IV JN: 21212 Page 10 IV.2. Site Design and Drainage Overview The ultimate plan of development for the proposed project is shown on the BMP Site Plan in Section VI of this report. The project Grading and Drainage Plan shows the proposed grading, drainage improvements, and site improvements associated with construction of the proposed residential building. IV.2.1 Site Design BMPs The project incorporates Site Design practices as follows: Minimize Impervious Area The project minimizes impervious area by minimizing walkway widths and by providing significant landscape areas throughout the site. IV.3 LID BMP Selection and Project Conformance Analysis Each sub-section below documents that the proposed design features conform to the applicable project performance criteria via check boxes, tables, calculations, narratives, and/or references to worksheets. IV.3.1 Hydrologic Source Controls (HSCs) If required HSCs are included, fill out applicable check box forms. If the retention criteria are otherwise met with other LID BMPs, include a statement indicating HSCs not required. Name Included? Localized on-lot infiltration Impervious area dispersion (e.g. roof top disconnection) Street trees (canopy interception) Residential rain barrels (not actively managed) Green roofs/Brown roofs Blue roofs Impervious area reduction (e.g. permeable pavers, site design) Use of HSCs is not required for this project since project conformance criteria are met through the use of infiltration BMPs. PA2022-067 Priority Project Water Quality Management Plan (WQMP) Project: OCEAN FRONT POOL HOUSE Owner: SMITH 507, LLC Section IV JN: 21212 Page 11 IV.3.2 Infiltration BMPs The Infiltration BMPs to be used for this project are indicated in the table below. Implementation of said controls is discussed in the text that follows. Name Included? Bioretention without underdrains Rain gardens Porous landscaping Infiltration planters Retention swales Infiltration trenches Infiltration basins Drywells Subsurface infiltration galleries French drains Permeable asphalt Permeable concrete Permeable concrete pavers Other: Feasibility Based on the Infiltration BMP Feasibility Worksheet in Attachment B, infiltration is permissible and feasible. Description An infiltration trench will be constructed at the southerly rear of the property boundary as shown on the BMP Site Plan in Section VI. The trench will be sized for the DCV for the entire project area. Sizing Per City of Newport Beach prescriptive requirement: “One 15’ long French drain per maximum of 2,000 sf of impervious area”. Gravel volume for City standard trench drain = 1.0 c. f. gravel volume/ft. trench length Gravel volume provided for this project: 27.4’L x 24”W x 18”D = 82.2 c.f. 𝑇𝑙𝑐𝑙𝑐� 𝑐𝑙𝑎𝑣𝑐𝑙 𝑣𝑙𝑙.𝑙𝑐𝑙′𝑐=�ℎ𝑙𝑙.𝑎𝑙𝑐𝑎 × 15′𝑙𝑙𝑐𝑙𝑐� 𝑙𝑐𝑙𝑐𝑙� 2,000 𝑙.𝑐.�ℎ𝑙𝑙.𝑎𝑙𝑐𝑎 × 1.0 𝑐.𝑐.𝑐𝑙𝑎𝑣𝑐𝑙 𝑣𝑙𝑙. 𝑐𝑙.𝑙𝑙𝑐𝑙𝑐� 𝑙𝑐𝑙𝑐𝑙� 𝑇𝑙𝑐𝑙𝑐� 𝑐𝑙𝑎𝑣𝑐𝑙 𝑙𝑐𝑙𝑐𝑙�.𝑙𝑐𝑙′𝑐=3,071 𝑙.𝑐.× 15 𝑐𝑙. 2,000 𝑙.𝑐.=𝟐𝟐 𝒇𝒕. Length Provided 27.4’ > Length Required 23’; … Size OK. PA2022-067 Priority Project Water Quality Management Plan (WQMP) Project: OCEAN FRONT POOL HOUSE Owner: SMITH 507, LLC Section IV JN: 21212 Page 12 IV.3.3 Evapotranspiration, Rainwater Harvesting BMPs If the full Design Storm Capture Volume cannot be met with infiltration BMPs, describe any evapotranspiration and/or rainwater harvesting BMPs included. Name Included? All HSCs; See Section IV.3.1 Surface-based infiltration BMPs Biotreatment BMPs Above-ground cisterns and basins Underground detention Other: Other: Other: Use of Evapotranspiration / Rainwater Harvesting BMPs is not required for this project since project conformance criteria are met through the use of infiltration BMPs. IV.3.4 Biotreatment BMPs Biofiltration BMPs to be used for this project are indicated in the table below. Implementation of said controls is discussed in the text that follows. Name Included? Bioretention with underdrains Stormwater planter boxes with underdrains Rain gardens with underdrains Constructed wetlands Vegetated swales Vegetated filter strips Proprietary vegetated biotreatment systems Wet extended detention basin Dry extended detention basins Use of Biotreatment BMPs is not required for this project since project conformance criteria are met through the use of infiltration BMPs. PA2022-067 Priority Project Water Quality Management Plan (WQMP) Project: OCEAN FRONT POOL HOUSE Owner: SMITH 507, LLC Section IV JN: 21212 Page 13 IV.3.5 Hydromodification Control BMPs Per Section II.3 of this WQMP, Hydromodification Control BMPs are not required. Hydromodification Control BMPs BMP Name BMP Description IV.3.6 Regional/Sub-Regional LID BMPs There are no Regional/Sub-Regional LID BMPs in which this project can participate. IV.3.7 Treatment Control BMPs Treatment Control BMPs to be used for this project are indicated in the table below. Implementation of said controls is discussed in the text that follows. Treatment Control BMPs BMP Name BMP Description PA2022-067 Priority Project Water Quality Management Plan (WQMP) Project: OCEAN FRONT POOL HOUSE Owner: SMITH 507, LLC Section IV JN: 21212 Page 14 IV.3.8 Non-structural Source Control BMPs Fill out non-structural source control check box forms or provide a brief narrative explaining if non- structural source controls were not used. Non-Structural Source Control BMPs Identifier Name Check One If not applicable, state brief reason Included Not Applicable N1 Education for Property Owners, Tenants and Occupants N2 Activity Restrictions Single Family Residence N3 Common Area Landscape Management N4 BMP Maintenance N5 Title 22 CCR Compliance (How development will comply) No hazardous waste. N6 Local Industrial Permit Compliance Not an industrial development. N7 Spill Contingency Plan No hazardous waste. N8 Underground Storage Tank Compliance No USTs. N9 Hazardous Materials Disclosure Compliance No hazardous materials. N10 Uniform Fire Code Implementation No hazardous materials. N11 Common Area Litter Control N12 Employee Training N13 Housekeeping of Loading Docks No loading docks. N14 Common Area Catch Basin Inspection N15 Street Sweeping Private Streets and Parking Lots Uncovered parking areas too small for street sweepers. N16 Retail Gasoline Outlets No gasoline dispensing. PA2022-067 Priority Project Water Quality Management Plan (WQMP) Project: OCEAN FRONT POOL HOUSE Owner: SMITH 507, LLC Section IV JN: 21212 Page 15 IV.3.9 Structural Source Control BMPs The following Structural Source Control BMPs shall be incorporated into the project. Structural Source Control BMPs Identifier Name Check One If not applicable, state brief reason Included Not Applicable S1 Provide storm drain system stenciling and signage No stenciling on small residential drain inlets. S2 Design and construct outdoor material storage areas to reduce pollution introduction No outdoor material storage areas S3 Design and construct trash and waste storage areas to reduce pollution introduction S4 Use efficient irrigation systems & landscape design, water conservation, smart controllers, and source control S5 Protect slopes and channels and provide energy dissipation No slopes present Incorporate requirements applicable to individual priority project categories (from SDRWQCB NPDES Permit) Santa Ana region project S6 Dock areas None present. S7 Maintenance bays None present. S8 Vehicle wash areas None present. S9 Outdoor processing areas None present. S10 Equipment wash areas None present. S11 Fueling areas None present. S12 Hillside landscaping Not a hillside area. S13 Wash water control for food preparation areas None present. S14 Community car wash racks None present. PA2022-067 Priority Project Water Quality Management Plan (WQMP) Project: OCEAN FRONT POOL HOUSE Owner: SMITH 507, LLC Section IV JN: 21212 Page 16 IV.4 Alternative Compliance Plan (If Applicable) An Alternative Compliance Plan was not considered for this project since the full DCV will be addressed using LID BMPs. IV.4.1 Water Quality Credits Determine if water quality credits are applicable for the project. Refer to Section 3.1 of the Model WQMP for description of credits and Appendix VI of the Technical Guidance Document (TGD) for calculation methods for applying water quality credits. Description of Proposed Project Project Types that Qualify for Water Quality Credits (Select all that apply): Redevelopment projects that reduce the overall impervious footprint of the project site. Brownfield redevelopment, meaning redevelopment, expansion, or reuse of real property which may be complicated by the presence or potential presence of hazardous substances, pollutants or contaminants, and which have the potential to contribute to adverse ground or surface WQ if not redeveloped. Higher density development projects which include two distinct categories (credits can only be taken for one category): those with more than seven units per acre of development (lower credit allowance); vertical density developments, for example, those with a Floor to Area Ratio (FAR) of 2 or those having more than 18 units per acre (greater credit allowance). Mixed use development, such as a combination of residential, commercial, industrial, office, institutional, or other land uses which incorporate design principles that can demonstrate environmental benefits that would not be realized through single use projects (e.g. reduced vehicle trip traffic with the potential to reduce sources of water or air pollution). Transit-oriented developments, such as a mixed use residential or commercial area designed to maximize access to public transportation; similar to above criterion, but where the development center is within one half mile of a mass transit center (e.g. bus, rail, light rail or commuter train station). Such projects would not be able to take credit for both categories, but may have greater credit assigned Redevelopment projects in an established historic district, historic preservation area, or similar significant city area including core City Center areas (to be defined through mapping). Developments with dedication of undeveloped portions to parks, preservation areas and other pervious uses. Developments in a city center area. Developments in historic districts or historic preservation areas. Live-work developments, a variety of developments designed to support residential and vocational needs together – similar to criteria to mixed use development; would not be able to take credit for both categories. In-fill projects, the conversion of empty lots and other underused spaces into more beneficially used spaces, such as residential or commercial areas. Calculation of Water Quality Credits (if applicable) None. PA2022-067 Priority Project Water Quality Management Plan (WQMP) Project: OCEAN FRONT POOL HOUSE Owner: SMITH 507, LLC Section IV JN: 21212 Page 17 IV.4.2 Alternative Compliance Plan Information Describe an alternative compliance plan (if applicable). Include alternative compliance obligations (i.e., gallons, pounds) and describe proposed alternative compliance measures. Refer to Section 7.II 3.0 in the Model WQMP. N/A Section V Inspection/Maintenance Responsibility for BMPs TBD. See Operations and Maintenance Plan in Attachment D. PA2022-067 Priority Project Water Quality Management Plan (WQMP) Project: OCEAN FRONT POOL HOUSE Owner: SMITH 507, LLC Section VI JN: 21212 Page 18 Section VI BMP Exhibit (Site Plan) VI.1 BMP Exhibit (Site Plan) Include a BMP Exhibit (Site Plan), at a size no less than 24” by 36,” which includes the following minimum information: • Insert in the title block (lower right hand corner) of BMP Exhibit: the WQMP Number (assigned by staff) and the grading/building or Planning Application permit numbers • Project location (address, tract/lot number(s), etc.) • Site boundary • Land uses and land covers, as applicable • Suitability/feasibility constraints • Structural BMP locations • Drainage delineations and flow information • Delineate the area being treated by each structural BMP • GIS coordinates for LID and Treatment Control BMPs • Drainage connections • BMP details • Preparer name and stamp Please do not include any areas outside of the project area or any information not related to drainage or water quality. The approved BMP Exhibit (Site Plan) shall be submitted as a plan sheet on all grading and building plan sets submitted for plan check review and approval. The BMP Exhibit shall be at the same size as the rest of the plan sheets in the submittal and shall have an approval stamp and signature prior to plan check submittal. VI.2 Submittal and Recordation of Water Quality Management Plan Following approval of the Final Project-Specific WQMP, three copies of the approved WQMP (including BMP Exhibit, Operations and Maintenance (O&M) Plan, and Appendices) shall be submitted. In addition, these documents shall be submitted in a PDF format. Each approved WQMP (including BMP Exhibit, Operations and Maintenance (O&M) Plan, and Appendices) shall be recorded in the Orange County Clerk-Recorder’s Office, prior to close-out of grading and/or building permit. Educational Materials are not required to be included. PA2022-067 F.F.=12.50F.F.=11.33GARAGE13 9 A v e n i d a N a v a r r oSan Clemente, CA 926729 4 9 . 4 9 2 . 8 5 8 6www.toalengineering.comCIVIL ENGINEERINGL A N D S U R V E Y I N GSTORMWATER QUALITYWQMP LEGENDPROPOSED BUILDINGPROPOSED LANDSCAPEPROPOSED HARDSCAPERUNOFF FLOW DIRECTIONPROPOSED STORM DRAININLETPROJECT AREA BOUNDARYINFILTRATION TRENCH / GRAVEL AREA1,877 S.F.78 S.F.67 S.F.1,116 S.F.3,071 S.F.DOWNSPOUT FILTERDETAILBOTTOMLESS TRENCH DRAINPA2022-067 Priority Project Water Quality Management Plan (WQMP) Project: OCEAN FRONT POOL HOUSE Owner: SMITH 507, LLC Section VII JN: 21212 Page 20 Section VII Educational Materials Refer to the Orange County Stormwater Program (ocwatersheds.com) for a library of materials available. Please only attach the educational materials specifically applicable to this project. Other materials specific to the project may be included as well and must be attached. Education Materials Residential Material (http://www.ocwatersheds.com) Check If Applicable Business Material (http://www.ocwatersheds.com) Check If Applicable The Ocean Begins at Your Front Door Tips for the Automotive Industry Tips for Car Wash Fund-raisers Tips for Using Concrete and Mortar Tips for the Home Mechanic Tips for the Food Service Industry Homeowners Guide for Sustainable Water Use Proper Maintenance Practices for Your Business Household Tips Other Material Check If Attached Proper Disposal of Household Hazardous Waste Recycle at Your Local Used Oil Collection Center (North County) Recycle at Your Local Used Oil Collection Center (Central County) Recycle at Your Local Used Oil Collection Center (South County) Tips for Maintaining a Septic Tank System Responsible Pest Control Sewer Spill Tips for the Home Improvement Projects Tips for Horse Care Tips for Landscaping and Gardening Tips for Pet Care Tips for Pool Maintenance Tips for Residential Pool, Landscape and Hardscape Drains Tips for Projects Using Paint PA2022-067 Priority Project Water Quality Management Plan (WQMP) Project: OCEAN FRONT POOL HOUSE Owner: SMITH 507, LLC Section VII JN: 21212 Page 21 ATTACHMENT A MAPS AND FIGURES PA2022-067 O R A N G E C O U N T Y O R A N G E C O U N T Y RI V E R S I D E C O U N T Y RI V E R S I D E C O U N T Y OR A N G E C O U N T Y OR A N G E C O U N T Y SA N B E R N A R D I N O C O U N T Y SA N B E R N A R D I N O C O U N T Y ORANGE COUNTYORANGE COUNTY LOS ANGELES COUNTYLOS ANGELES COUNTY ORANGE COUNTYORANGE COUNTYLOS ANGELES COUNTYLOS ANGELES COUNTY1.05 0.7 10 . 9 50.90.850.80.75 0 . 70.65 0.9 5 0.70.90.9 0.7 5 P:\9526E\6-GIS\Mxds\Reports\InfiltrationFeasability_20110215\9526E_FigureXVI-1_RainfallZones_20110215.mxdFIGUREJOBTITLESCALE1" = 1.8 milesDESIGNEDDRAWINGCHECKEDBMP04/22/10DATEJOB NO.9526-ETHTHORANGE COUNTYTECHNICAL GUIDANCEDOCUMENTORANGE CO.CARAINFALL ZONESSUBJECT TO FURTHER REVISION 0 3.6 7.21.8 Miles 0 6 123 Kilometers LEGEND Orange County Precipitation Stations 24 Hour, 85th Percentile Rainfall (Inches) 24 Hour, 85th Percentile Rainfall (Inches) - Extrapolated City Boundaries Rainfall ZonesDesign Capture Storm Depth (inches) 0.65" 0.7 0.75 0.80 0.85 0.90 0.95 1.00 1.10" Note: Events defined as 24-hour periods (calendar days) with greater than 0.1 inches of rainfall. For areas outside of available data coverage, professional judgment shall be applied. XVI-1 PA2022-067 O R A N G E C O U N T Y O R A N G E C O U N T Y RI V E R S I D E C O U N T Y RI V E R S I D E C O U N T Y OR A N G E C O U N T Y OR A N G E C O U N T Y SA N B E R N A R D I N O C O U N T Y SA N B E R N A R D I N O C O U N T Y ORANGE COUNTYORANGE COUNTYLOS ANGELES COUNTYLOS ANGELES COUNTY ORANGE COUNTYORANGE COUNTYLOS ANGELES COUNTYLOS ANGELES COUNTYP:\9526E\6-GIS\Mxds\Reports\InfiltrationFeasability_20110215\9526E_FigureXVI-2a_HydroSoils_20110215.mxdFIGURE XVI-2aJOBTITLESCALE1" = 1.8 milesDESIGNEDDRAWINGCHECKEDBMP02/09/11DATEJOB NO.9526-ETHTHORANGE COUNTYINFILTRATION STUDYORANGE CO.CANRCS HYDROLOGICSOILS GROUPSSUBJECT TO FURTHER REVISION Source: Soils: Natural Resources Conservation Service (NRCS) Soil Survey - soil_ca678, Orange County & Western Riverside Date of publication: 2006-02-08 !I 0 3.6 7.21.8 Miles 0 5 102.5 Kilometers LEGEND City Boundaries Hydrologic Soil Groups A Soils B Soils C Soils D Soils http://websoilsurvey.nrcs.usda.gov/app/HomePage.htm PA2022-067 O R A N G E C O U N T Y O R A N G E C O U N T Y RI V E R S I D E C O U N T Y RI V E R S I D E C O U N T Y OR A N G E C O U N T Y OR A N G E C O U N T Y SA N B E R N A R D I N O C O U N T Y SA N B E R N A R D I N O C O U N T Y ORANGE COUNTYORANGE COUNTY LOS ANGELES COUNTYLOS ANGELES COUNTY ORANGE COUNTYORANGE COUNTYLOS ANGELES COUNTYLOS ANGELES COUNTYP:\9526E\6-GIS\Mxds\Reports\InfiltrationFeasability_20110215\9526E_FigureXVI-2e_DepthToGroundwaterLt5ft_20110215.mxdFIGURE XVI-2eJOBTITLESCALE1" = 1.25 milesDESIGNEDDRAWINGCHECKEDBMP02/09/11DATEJOB NO.9526-ETHTHORANGE COUNTYINFILTRATION STUDYORANGE CO.CANORTH ORANGE COUNTYMAPPED SHALLOW GROUNDWATERSUBJECT TO FURTHER REVISION Note: Data are not available for South Orange County at this time. Source: Sprotte, Fuller and Greenwood, 1980. California Division of Mines and Geology; California Geological Survey !I 0 2.5 51.25 Miles 0 4 82 Kilometers LEGEND City Boundaries OCWD Groundwater Basin Protection Boundary Depth To Groundwater <= 5' 5-10' PA2022-067 P:\9526E\6-GIS\Mxds\SuceptabilityMaps_20100505\9526E_NewportBaySusceptibility_20100430.mxdRiverside County Santa Ana River Watershed Santa Ana River Watershed South OrangeCounty Anaheim Bay-Huntington Harbor Watershed JohnWayneAirport Lower PetersCanyonRetarding Basin Hicks CanyonRetardingBasin SiphonReservoir Round CanyonRetardingBasin Bee CanyonRetardingBasin EastfootRetardingBasin Orchard EstatesRetention Basin Agua ChinonRetardingBasin VillagePond Park Sand CanyonReservoir San JoaquinReservoir LagunaReservoir Big CanyonReservoir BonitaCanyonReservoir BasinNumber 1 NorthLake SouthLake BasinNumber 2 El Modena-IrvineRetarding Basin HarborView Dam East HicksCanyonRetarding Basin RattlesnakeReservoir TrabucoRetardingBasin MarshburnRetardingBasin FIGURE 4JOBTITLESCALE1" = 12000'DESIGNEDDRAWINGCHECKEDBMP04/30/10DATEJOB NO.9526-ETHTHORANGE COUNTYWATERSHEDMASTER PLANNINGORANGE CO.CASUSCEPTIBILITY ANALYISNEWPORT BAY-NEWPORT COASTAL STREAMS!I 0 9,000 18,000 Feet Susceptibility Potential Areas of Erosion, Habitat, & Physical Structure Susceptibility Channel Type Earth (Unstable) Earth (Stabilized) Stabilized Tidel Influence <= Mean High Water Line (4.28') Water Body Basin Dam Lake Reservoir Other Lands Airport/Military SUSCEPTIBILITY MAP UPATE (FEB 2013)PA2022-067 P:\9526E\6-GIS\Mxds\SuceptabilityMaps_20100505\9526E_NewportBaySusceptibility_20100430.mxdRiverside County Santa Ana River Watershed Santa Ana River Watershed South OrangeCounty Anaheim Bay-Huntington Harbor Watershed JohnWayneAirport Lower PetersCanyonRetarding Basin Hicks CanyonRetardingBasin SiphonReservoir Round CanyonRetardingBasin Bee CanyonRetardingBasin EastfootRetardingBasin Orchard EstatesRetention Basin Agua ChinonRetardingBasin VillagePond Park Sand CanyonReservoir San JoaquinReservoir LagunaReservoir Big CanyonReservoir BonitaCanyonReservoir BasinNumber 1 NorthLake SouthLake BasinNumber 2 El Modena-IrvineRetarding Basin HarborView Dam East HicksCanyonRetarding Basin RattlesnakeReservoir TrabucoRetardingBasin MarshburnRetardingBasin FIGURE 4JOBTITLESCALE1" = 12000'DESIGNEDDRAWINGCHECKEDBMP04/30/10DATEJOB NO.9526-ETHTHORANGE COUNTYWATERSHEDMASTER PLANNINGORANGE CO.CASUSCEPTIBILITY ANALYISNEWPORT BAY-NEWPORT COASTAL STREAMS!I 0 9,000 18,000 Feet Susceptibility Potential Areas of Erosion, Habitat, & Physical Structure Susceptibility Channel Type Earth (Unstable) Earth (Stabilized) Stabilized Tidel Influence <= Mean High Water Line (4.28') Water Body Basin Dam Lake Reservoir Other Lands Airport/Military SUSCEPTIBILITY MAP UPATE (FEB 2013)PA2022-067 Priority Project Water Quality Management Plan (WQMP) Project: OCEAN FRONT POOL HOUSE Owner: SMITH 507, LLC Section VII JN: 21212 Page 22 ATTACHMENT B BMP FACT SHEETS AND CALCULATIONS PA2022-067 Priority Project Water Quality Management Plan (WQMP) Project: OCEAN FRONT POOL HOUSE Owner: SMITH 507, LLC Section VII JN: 21212 Page 23 ATTACHMENT C EDUCATIONAL MATERIALS PA2022-067 Priority Project Water Quality Management Plan (WQMP) Project: OCEAN FRONT POOL HOUSE Owner: SMITH 507, LLC Section VII JN: 21212 Page 24 ATTACHMENT D OPERATION & MAINTENANCE PLAN PA2022-067 Priority Project Water Quality Management Plan (WQMP) Project: OCEAN FRONT POOL HOUSE Owner: SMITH 507, LLC Section VII JN: 21212 Page 25 ATTACHMENT E GEOTECHNICAL REPORTS PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 PA2022-067 From:Coast Geotechnical, Inc. To:Alexander Vlosky Subject:Re: 1616 W Oceanfront - Newport Beach - Infiltration Date:Tuesday, March 22, 2022 8:12:18 AM Hi Alex, The infiltration location is fine. Thank You,Dan Coast Geotechnical, Inc.1200 W. Commonwealth AvenueFullerton, CA 92833(714) 870-1211 On Monday, 21 March 2022, 03:18:37 pm GMT-7, Alexander Vlosky <avlosky@toalengineering.com> wrote: Hi Ming, We have a preliminary plan with a bottomless infiltration trench that is farther than 5’ from the building (11.32’ total). Could you take a quick look and let us know if this is acceptable and if you see any issues? Thanks, Alex Vlosky, P.E. Toal Engineering, Inc. CIVIL ENGINEERS ● LAND SURVEYORS 139 Avenida Navarro San Clemente, CA 92672 Tel: (949) 492-8586 x119 Direct Line: (949) 352-4869 PA2022-067