Loading...
HomeMy WebLinkAboutPA2022-136_20220823_Plans_Final7 8 3 4 5 6 2101 Carrillo Privado, Ontario, CA 91761 (909) 930-0303 Fax: (909) 930-0308 E-mail: design@signindustries.tv Web: www.signindustries.tv Page: Location: Date: Sales Rep: Client Approval: Project: Date of Approval: Drawn by: Drawing No All ideas, plans or arrangements indicated on this drawing are copyrighted and owned by Sign Industries Incorporated and shall not be reproduced, used by or disclosed to any persons, firm or corporation for any purpose whatsoever without written permission of Sign Industries Incorporated. Electrical Requirement: 120 Volts 277 Volts Luis Soria / Sign cad drafter date: 08/23/22 Paul L. 2122 BRISTOL ST, NEWPORT BEACH, CA 92660 03-26-22 L.S. 822-117 08-19-22 L.S. 08-23-22 L.S. 06-01-22 L.S. 06-13-22 L.S. 08-02-22 L.S. 08-18-22 L.S. BRISTOL & BIRCH STARBUCKS COFFEE PROJECT: # 93058-001 STORE # 67355 2122 BRISTOL ST, NEWPORT BEACH, CA 92660 N VICINITY MAP Not To Scale 48” SIREN LOGO DISC B A C 48" DT ILLUM. CABINET 12" CHANNEL LETTERS SIGN ID SIGN TYPE QTY DIMENSIONS ILLUMINATED SIGN AREA 2 1 48” DIAM 16 SQ FT.YES 10 SQ FT.YES1’ X 9’-8” 1’-9” X 3’-11 3/4”1 YES 7 SQ FT. D DRIVE THRU DIRECTIONAL 1 1’-3” X 2’-7”3.2 SQ FT.YES F CLEARANCE BAR 1 NO 2.3 SQ FT.5” X 5’-6” G PRE MENU SIGN 1 3’-5 3/8” X 2’-5 1/8”YES 8.3 SQ FT. H.1 DRIVE THRU CANOPY 1 10’-3 7/8” X 4’-6”NO N/A H.2 DRIVE THRU ORDER SCREEN 1 4’-1 3/4” X 3’-1 1/2”YES 1313 SQ FT I MENU BOARD 1 3’-6 3/4” X 7’-10 1/2”YES 28.06 SQ FT J EXISTING PYLON SIGN 1 8FT DIAM/ 1’X6 PANEL YES 70 SQ FT K R5-1 POST AND PANEL SIGN 1 2’-0” X 2’-0”NO 4 SQ FT L EXISTING ADDRESS NUMBERS 1 8” X 21”NO 1.2 FT Luis Soria / Sign cad drafter date: 08/23/22 cell:909 996 9598 CONSTRUCTION NOTES: A. ALL WORK TO COMPLY WITH 2019 CA BUILDING CODES AND 2019 CALIFORNIA EFFICIENCY STANDARDS FOR SIGN LIGHTING. B. A 20 AMP DEDICATED CIRCUIT FOR SIGNAGE WITH ASTRONOMICAL TIME CLOCK CONTROL SHALL BE PROVIDED. C. SIGN INSTALLER SHALL IDENTIFY SIGN CIRCUIT BREAKER AND UPDATE PANEL DIRECTORY 7 8 3 4 5 6 2101 Carrillo Privado, Ontario, CA 91761 (909) 930-0303 Fax: (909) 930-0308 E-mail: design@signindustries.tv Web: www.signindustries.tv Page: Location: Date: Sales Rep: Client Approval: Project: Date of Approval: Drawn by: Drawing No All ideas, plans or arrangements indicated on this drawing are copyrighted and owned by Sign Industries Incorporated and shall not be reproduced, used by or disclosed to any persons, firm or corporation for any purpose whatsoever without written permission of Sign Industries Incorporated. Electrical Requirement: 120 Volts 277 Volts Luis Soria / Sign cad drafter date: 08/23/22 Paul L. 2122 BRISTOL ST, NEWPORT BEACH, CA 92660 03-26-22 L.S. 822-117 08-19-22 L.S. 08-23-22 L.S. 06-01-22 L.S. 06-13-22 L.S. 08-02-22 L.S. 08-18-22 L.S. 74 FT PRIMARY FRONTAGE - FACING BIRCH ST 37 FT PRIMARY FRONTAGE - BRISTOL ST 111 48 21’-4” 55.5 N/A 48 74 FT PRIMARY FRONTAGE - FACING BIRCH ST 37 FT PRIMARY FRONTAGE - BRISTOL ST 2122 Bristol St.111 sq ft max of total sign area allowed 48in max height, 21’-4” minimum distance between signs 55.5 sq ft of total sign area allowed 48” in max height2122 Bristol St. CP.01 SP.1 N SITE PLAN SCALE: NTS1 7 8 3 4 5 6 2101 Carrillo Privado, Ontario, CA 91761 (909) 930-0303 Fax: (909) 930-0308 E-mail: design@signindustries.tv Web: www.signindustries.tv Page: Location: Date: Sales Rep: Client Approval: Project: Date of Approval: Drawn by: Drawing No All ideas, plans or arrangements indicated on this drawing are copyrighted and owned by Sign Industries Incorporated and shall not be reproduced, used by or disclosed to any persons, firm or corporation for any purpose whatsoever without written permission of Sign Industries Incorporated. Electrical Requirement: 120 Volts 277 Volts Luis Soria / Sign cad drafter date: 08/23/22 Paul L. 2122 BRISTOL ST, NEWPORT BEACH, CA 92660 03-26-22 L.S. 822-117 08-19-22 L.S. 08-23-22 L.S. 06-01-22 L.S. 06-13-22 L.S. 08-02-22 L.S. 08-18-22 L.S. KEY LEGEND 48” SIREN LOGO DISC DT 5 PANEL MENU SIGN ORDER SCREEN CANOPY CLEARANCE BAR D/T DIRECTIONAL PRE MENU BOARD 48" DT ILLUM. CABINET 12" CHANNEL LETTERS B B A C D F G H.1 I AC A D F G H.1 I K H.2 DIGITAL ORDER SCREEN H.2 EXISTING PYLON SIGNJ J R5-1 POST AND PANELK K EXISTING ADDRESS NUMBERSL L 7’ 7 8 3 4 5 6 2101 Carrillo Privado, Ontario, CA 91761 (909) 930-0303 Fax: (909) 930-0308 E-mail: design@signindustries.tv Web: www.signindustries.tv Page: Location: Date: Sales Rep: Client Approval: Project: Date of Approval: Drawn by: Drawing No All ideas, plans or arrangements indicated on this drawing are copyrighted and owned by Sign Industries Incorporated and shall not be reproduced, used by or disclosed to any persons, firm or corporation for any purpose whatsoever without written permission of Sign Industries Incorporated. Electrical Requirement: 120 Volts 277 Volts Luis Soria / Sign cad drafter date: 08/23/22 Paul L. 2122 BRISTOL ST, NEWPORT BEACH, CA 92660 03-26-22 L.S. 822-117 08-19-22 L.S. 08-23-22 L.S. 06-01-22 L.S. 06-13-22 L.S. 08-02-22 L.S. 08-18-22 L.S. ELEV.1 NORTHWEST ELEVATION - FACING BIRCH STREET SCALE: 1/8" = 1' - 0"1 NORTHEAST ELEVATION - FACING BRISTOL STREET SCALE: 1/8" = 1' - 0"2 KEY LEGEND 48” SIREN LOGO DISC B A C 48" DT ILLUM. CABINET 12" CHANNEL LETTERS 15'-9"15'-9"A 4'-0"EQ EQ 12'-11"C L 9'-8"EQ EQ 48" 1'-9" EQ EQ C 4'-0"EQ EQ A 12'-11"C L 1'-0"B EQ EQ 74'-0" PRIMARY FRONTAGE 37'-0" SECONDARY FRONTAGE 21’-4 1/2”26’-1 1/4” 7’-0” 7’-0” L EXISTING ADDRESS NUMBERS L L EXISTING ADDRESS NUMBERS TO BE REPAINTED BLACK 2122 8” 21” 7 8 3 4 5 6 2101 Carrillo Privado, Ontario, CA 91761 (909) 930-0303 Fax: (909) 930-0308 E-mail: design@signindustries.tv Web: www.signindustries.tv Page: Location: Date: Sales Rep: Client Approval: Project: Date of Approval: Drawn by: Drawing No All ideas, plans or arrangements indicated on this drawing are copyrighted and owned by Sign Industries Incorporated and shall not be reproduced, used by or disclosed to any persons, firm or corporation for any purpose whatsoever without written permission of Sign Industries Incorporated. Electrical Requirement: 120 Volts 277 Volts Luis Soria / Sign cad drafter date: 08/23/22 Paul L. 2122 BRISTOL ST, NEWPORT BEACH, CA 92660 03-26-22 L.S. 822-117 08-19-22 L.S. 08-23-22 L.S. 06-01-22 L.S. 06-13-22 L.S. 08-02-22 L.S. 08-18-22 L.S. SOUTHWEST ELEVATION - FACING PARKING LOT SCALE: 1/8" = 1' - 0"1 ELEV.2 SOUTHEAST ELEVATION - FACING DT LANE SCALE: 1/8" = 1' - 0"2 L.S. 7 8 3 4 5 6 2101 Carrillo Privado, Ontario, CA 91761 (909) 930-0303 Fax: (909) 930-0308 E-mail: design@signindustries.tv Web: www.signindustries.tv Page: Location: Date: Sales Rep: Client Approval: Project: Date of Approval: Drawn by: Drawing No All ideas, plans or arrangements indicated on this drawing are copyrighted and owned by Sign Industries Incorporated and shall not be reproduced, used by or disclosed to any persons, firm or corporation for any purpose whatsoever without written permission of Sign Industries Incorporated. Electrical Requirement: 120 Volts 277 Volts Luis Soria / Sign cad drafter date: 08/23/22 Paul L. 2122 BRISTOL ST, NEWPORT BEACH, CA 92660 03-26-22 L.S. 822-117 08-19-22 L.S. 08-23-22 L.S. 06-01-22 L.S. 06-13-22 L.S. 08-02-22 L.S. 08-18-22 L.S. 1.0 A QTY : 2 L.S. 16 PRIMARY ELECTRICAL TO SIGN LOCATIONS TO BE PROVIDED BY OTHERS. A DEDICATED CIRCUIT WITH NO SHARED NEUTRALS AND A GROUND RETURNING TO THE PANEL IS REQUIRED FOR INSTALLATION. ALL TRANSFORMERS SHALL BE, (GFI) GROUND FAULT-INTERRUPTED TRANSFORMERS. ALL SIGNS HAVE - DEDICATED BRANCH CIRCUIT - THREE WIRES : LINE, NEUTRAL, & GROUND - WIRE SIZE : MINIMUM OF 12 GA. THHN COPPER WIRE ALSO NOTE: GAUGE OF WIRE IS DETERMINED BY THE LENGTH OF RUN & AMPERAGE AS PER NEC ARTICLE 300. - GROUND WIRE MUST BE CONTINUOUS AND GO FROM THE SIGN TO THE PANELBOARD GROUND BUS. - VOLTAGE SHOULD READ NO MORE THAN 3 VOLTS BETWEEN GROUND AND NEUTRAL. - CONDUIT CAN NOT BE USED AS GROUND PATH - A UL DISCONNECT SWITCH IS IN THE SIGN OR REMOTE POWER SUPPLY BO -SIGN CIRCUIT MUST BE ON A LIGHTING CONTROL PANEL, ASTRONOMICAL TIME CLOCK OR PHOTO CELL ALONG W/ 24 HR TIME CLOCK - POWER TO SIGN MUST BE DONE BY A LICENSED ELECTRICIAN OR ELECTRICAL CONTRACTOR. This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. This includes proper grounding and bonding of the sign. REQUIREMENTS FOR ELECTRICAL ILLUMINATION: ____ Dedicated ____ Amp Circuit at _____ Volts201201 Wood Framed Wall/Stucco finish 3/8" X 5” (6 per logo) lag bolt - threads to fully engage & penetrate plywood sheathing Minimum 5/8" [16 mm] thick plywood sheathing 7 8 3 4 5 6 2101 Carrillo Privado, Ontario, CA 91761 (909) 930-0303 Fax: (909) 930-0308 E-mail: design@signindustries.tv Web: www.signindustries.tv Page: Location: Date: Sales Rep: Client Approval: Project: Date of Approval: Drawn by: Drawing No All ideas, plans or arrangements indicated on this drawing are copyrighted and owned by Sign Industries Incorporated and shall not be reproduced, used by or disclosed to any persons, firm or corporation for any purpose whatsoever without written permission of Sign Industries Incorporated. Electrical Requirement: 120 Volts 277 Volts Luis Soria / Sign cad drafter date: 08/23/22 Paul L. 2122 BRISTOL ST, NEWPORT BEACH, CA 92660 03-26-22 L.S. 822-117 08-19-22 L.S. 08-23-22 L.S. 06-01-22 L.S. 06-13-22 L.S. 08-02-22 L.S. 08-18-22 L.S. 2.0 Faces letters 1/4" white acrylic with 3M day/nite perforated vinyl overlay, with white 3M diffuser second surface. 1/4 white Acrylic Face B QTY - 1 TRIMLESS DAY/NITE CHANNEL LETTERS - REMOTE 10 PRIMARY ELECTRICAL TO SIGN LOCATIONS TO BE PROVIDED BY OTHERS. A DEDICATED CIRCUIT WITH NO SHARED NEUTRALS AND A GROUND RETURNING TO THE PANEL IS REQUIRED FOR INSTALLATION. ALL TRANSFORMERS SHALL BE, (GFI) GROUND FAULT-INTERRUPTED TRANSFORMERS. ALL SIGNS HAVE - DEDICATED BRANCH CIRCUIT - THREE WIRES : LINE, NEUTRAL, & GROUND - WIRE SIZE : MINIMUM OF 12 GA. THHN COPPER WIRE ALSO NOTE: GAUGE OF WIRE IS DETERMINED BY THE LENGTH OF RUN & AMPERAGE AS PER NEC ARTICLE 300. - GROUND WIRE MUST BE CONTINUOUS AND GO FROM THE SIGN TO THE PANELBOARD GROUND BUS. - VOLTAGE SHOULD READ NO MORE THAN 3 VOLTS BETWEEN GROUND AND NEUTRAL. - CONDUIT CAN NOT BE USED AS GROUND PATH - A UL DISCONNECT SWITCH IS IN THE SIGN OR REMOTE POWER SUPPLY BO -SIGN CIRCUIT MUST BE ON A LIGHTING CONTROL PANEL, ASTRONOMICAL TIME CLOCK OR PHOTO CELL ALONG W/ 24 HR TIME CLOCK - POWER TO SIGN MUST BE DONE BY A LICENSED ELECTRICIAN OR ELECTRICAL CONTRACTOR. This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. This includes proper grounding and bonding of the sign. REQUIREMENTS FOR ELECTRICAL ILLUMINATION: ____ Dedicated ____ Amp Circuit at _____ Volts201201 1/4" X 3”(3 per letter) lag bolt - threads to fully engage & penetrate plywood sheathing Minimum 5/8" [16 mm] thick plywood sheathing Wood Framed Wall/Stucco finish 7 8 3 4 5 6 2101 Carrillo Privado, Ontario, CA 91761 (909) 930-0303 Fax: (909) 930-0308 E-mail: design@signindustries.tv Web: www.signindustries.tv Page: Location: Date: Sales Rep: Client Approval: Project: Date of Approval: Drawn by: Drawing No All ideas, plans or arrangements indicated on this drawing are copyrighted and owned by Sign Industries Incorporated and shall not be reproduced, used by or disclosed to any persons, firm or corporation for any purpose whatsoever without written permission of Sign Industries Incorporated. Electrical Requirement: 120 Volts 277 Volts Luis Soria / Sign cad drafter date: 08/23/22 Paul L. 2122 BRISTOL ST, NEWPORT BEACH, CA 92660 03-26-22 L.S. 822-117 08-19-22 L.S. 08-23-22 L.S. 06-01-22 L.S. 06-13-22 L.S. 08-02-22 L.S. 08-18-22 L.S. 3.0 Design ID#14099 1: Figured as illuminated center part 2: Figured as complete signage 48” Illuminated Drive-Thru w/ Right Arrow - Wall Mounted ~ Qty(1) Scale: 3/4”= 1’ Left View 2 Front View Right View 3 Service Position View Vertical Cross-Section View NTS NTS Prism Enlighten white 6500K LED’s Internally illuminated logo disc with Sloan Prism Enlightne white 6500k, laid out at 1.5 modules per foot, 7” on center installed to back of disk with self-contained power supply with U.L approved enclosure. Power Supply Section View at Installation Detail 3/8" X 3” lag bolt - threads to fully engage & penetrate plywood sheathing 3 1/2" 3 7/8" [89mm] [98mm]1'-2 1/2" [368mm]Minimum 5/8" [16 mm] thick plywood sheathing C 7 PRIMARY ELECTRICAL TO SIGN LOCATIONS TO BE PROVIDED BY OTHERS. A DEDICATED CIRCUIT WITH NO SHARED NEUTRALS AND A GROUND RETURNING TO THE PANEL IS REQUIRED FOR INSTALLATION. ALL TRANSFORMERS SHALL BE, (GFI) GROUND FAULT-INTERRUPTED TRANSFORMERS. ALL SIGNS HAVE - DEDICATED BRANCH CIRCUIT - THREE WIRES : LINE, NEUTRAL, & GROUND - WIRE SIZE : MINIMUM OF 12 GA. THHN COPPER WIRE ALSO NOTE: GAUGE OF WIRE IS DETERMINED BY THE LENGTH OF RUN & AMPERAGE AS PER NEC ARTICLE 300. - GROUND WIRE MUST BE CONTINUOUS AND GO FROM THE SIGN TO THE PANELBOARD GROUND BUS. - VOLTAGE SHOULD READ NO MORE THAN 3 VOLTS BETWEEN GROUND AND NEUTRAL. - CONDUIT CAN NOT BE USED AS GROUND PATH - A UL DISCONNECT SWITCH IS IN THE SIGN OR REMOTE POWER SUPPLY BO -SIGN CIRCUIT MUST BE ON A LIGHTING CONTROL PANEL, ASTRONOMICAL TIME CLOCK OR PHOTO CELL ALONG W/ 24 HR TIME CLOCK - POWER TO SIGN MUST BE DONE BY A LICENSED ELECTRICIAN OR ELECTRICAL CONTRACTOR. This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. This includes proper grounding and bonding of the sign. REQUIREMENTS FOR ELECTRICAL ILLUMINATION: ____ Dedicated ____ Amp Circuit at _____ Volts201201Wood Framed Wall/Stucco finish 7 8 3 4 5 6 2101 Carrillo Privado, Ontario, CA 91761 (909) 930-0303 Fax: (909) 930-0308 E-mail: design@signindustries.tv Web: www.signindustries.tv Page: Location: Date: Sales Rep: Client Approval: Project: Date of Approval: Drawn by: Drawing No All ideas, plans or arrangements indicated on this drawing are copyrighted and owned by Sign Industries Incorporated and shall not be reproduced, used by or disclosed to any persons, firm or corporation for any purpose whatsoever without written permission of Sign Industries Incorporated. Electrical Requirement: 120 Volts 277 Volts Luis Soria / Sign cad drafter date: 08/23/22 Paul L. 2122 BRISTOL ST, NEWPORT BEACH, CA 92660 03-26-22 L.S. 822-117 08-19-22 L.S. 08-23-22 L.S. 06-01-22 L.S. 06-13-22 L.S. 08-02-22 L.S. 08-18-22 L.S. 5.0 D/F DRIVE THRU DIRECTIONAL SIGNS~ Qty (1) Scale: 1”= 1’ D Side Street View 1 Front View 2 Store Side View 3 Rear View 4 Design ID#14104 Prism Enlighten white 6500K LED’s Power Supply Internally illuminated logo disc with Sloan Prism Enlighten white 6500k, laid out at 1.5 modules per foot, 7” on center with self-contained power supply with U.L approved enclosure. 3.2 PRIMARY ELECTRICAL TO SIGN LOCATIONS TO BE PROVIDED BY OTHERS. A DEDICATED CIRCUIT WITH NO SHARED NEUTRALS AND A GROUND RETURNING TO THE PANEL IS REQUIRED FOR INSTALLATION. ALL TRANSFORMERS SHALL BE, (GFI) GROUND FAULT-INTERRUPTED TRANSFORMERS. ALL SIGNS HAVE - DEDICATED BRANCH CIRCUIT - THREE WIRES : LINE, NEUTRAL, & GROUND - WIRE SIZE : MINIMUM OF 12 GA. THHN COPPER WIRE ALSO NOTE: GAUGE OF WIRE IS DETERMINED BY THE LENGTH OF RUN & AMPERAGE AS PER NEC ARTICLE 300. - GROUND WIRE MUST BE CONTINUOUS AND GO FROM THE SIGN TO THE PANELBOARD GROUND BUS. - VOLTAGE SHOULD READ NO MORE THAN 3 VOLTS BETWEEN GROUND AND NEUTRAL. - CONDUIT CAN NOT BE USED AS GROUND PATH - A UL DISCONNECT SWITCH IS IN THE SIGN OR REMOTE POWER SUPPLY BO -SIGN CIRCUIT MUST BE ON A LIGHTING CONTROL PANEL, ASTRONOMICAL TIME CLOCK OR PHOTO CELL ALONG W/ 24 HR TIME CLOCK - POWER TO SIGN MUST BE DONE BY A LICENSED ELECTRICIAN OR ELECTRICAL CONTRACTOR. This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. This includes proper grounding and bonding of the sign. REQUIREMENTS FOR ELECTRICAL ILLUMINATION: ____ Dedicated ____ Amp Circuit at _____ Volts201201 7 8 3 4 5 6 2101 Carrillo Privado, Ontario, CA 91761 (909) 930-0303 Fax: (909) 930-0308 E-mail: design@signindustries.tv Web: www.signindustries.tv Page: Location: Date: Sales Rep: Client Approval: Project: Date of Approval: Drawn by: Drawing No All ideas, plans or arrangements indicated on this drawing are copyrighted and owned by Sign Industries Incorporated and shall not be reproduced, used by or disclosed to any persons, firm or corporation for any purpose whatsoever without written permission of Sign Industries Incorporated. Electrical Requirement: 120 Volts 277 Volts Luis Soria / Sign cad drafter date: 08/23/22 Paul L. 2122 BRISTOL ST, NEWPORT BEACH, CA 92660 03-26-22 L.S. 822-117 08-19-22 L.S. 08-23-22 L.S. 06-01-22 L.S. 06-13-22 L.S. 08-02-22 L.S. 08-18-22 L.S. 5.1 SEE SEP ARA TE ENGINEERI N G SEE SEP ARA TE ENGINEERI N G SUBMITT AL FOR SCALED E N G I N E E R I N G SUBMITT AL FOR SCALED E N G I N E E R I N G AND LEGIBLE C O P Y / C A L C U L A TIONS AND LEGIBLE C O P Y / C A L C U L A TIONSSEE SEP ARA TE ENGINEERI N G SUBMITT AL FOR SCALED E N G I N E E R I N G AND LEGIBLE C O P Y / C A L C U L A TIONS 7 8 3 4 5 6 2101 Carrillo Privado, Ontario, CA 91761 (909) 930-0303 Fax: (909) 930-0308 E-mail: design@signindustries.tv Web: www.signindustries.tv Page: Location: Date: Sales Rep: Client Approval: Project: Date of Approval: Drawn by: Drawing No All ideas, plans or arrangements indicated on this drawing are copyrighted and owned by Sign Industries Incorporated and shall not be reproduced, used by or disclosed to any persons, firm or corporation for any purpose whatsoever without written permission of Sign Industries Incorporated. Electrical Requirement: 120 Volts 277 Volts Luis Soria / Sign cad drafter date: 08/23/22 Paul L. 2122 BRISTOL ST, NEWPORT BEACH, CA 92660 03-26-22 L.S. 822-117 08-19-22 L.S. 08-23-22 L.S. 06-01-22 L.S. 06-13-22 L.S. 08-02-22 L.S. 08-18-22 L.S. 7.0 Design ID#22544 CONCEPTUAL RENDERING FREESTANDING -DT CLEARNANCE BAR ARROW SERIES~ Qty (1) F 5’-6” 5" 2.3 7 8 3 4 5 6 2101 Carrillo Privado, Ontario, CA 91761 (909) 930-0303 Fax: (909) 930-0308 E-mail: design@signindustries.tv Web: www.signindustries.tv Page: Location: Date: Sales Rep: Client Approval: Project: Date of Approval: Drawn by: Drawing No All ideas, plans or arrangements indicated on this drawing are copyrighted and owned by Sign Industries Incorporated and shall not be reproduced, used by or disclosed to any persons, firm or corporation for any purpose whatsoever without written permission of Sign Industries Incorporated. Electrical Requirement: 120 Volts 277 Volts Luis Soria / Sign cad drafter date: 08/23/22 Paul L. 2122 BRISTOL ST, NEWPORT BEACH, CA 92660 03-26-22 L.S. 822-117 08-19-22 L.S. 08-23-22 L.S. 06-01-22 L.S. 06-13-22 L.S. 08-02-22 L.S. 08-18-22 L.S. 7.1 7 8 3 4 5 6 2101 Carrillo Privado, Ontario, CA 91761 (909) 930-0303 Fax: (909) 930-0308 E-mail: design@signindustries.tv Web: www.signindustries.tv Page: Location: Date: Sales Rep: Client Approval: Project: Date of Approval: Drawn by: Drawing No All ideas, plans or arrangements indicated on this drawing are copyrighted and owned by Sign Industries Incorporated and shall not be reproduced, used by or disclosed to any persons, firm or corporation for any purpose whatsoever without written permission of Sign Industries Incorporated. Electrical Requirement: 120 Volts 277 Volts Luis Soria / Sign cad drafter date: 08/23/22 Paul L. 2122 BRISTOL ST, NEWPORT BEACH, CA 92660 03-26-22 L.S. 822-117 08-19-22 L.S. 08-23-22 L.S. 06-01-22 L.S. 06-13-22 L.S. 08-02-22 L.S. 08-18-22 L.S. 7.2 SEE SEP ARA TE ENGINEERI N G SEE SEP ARA TE ENGINEERI N G SUBMITT AL FOR SCALED E N G I N E E R I N G SUBMITT AL FOR SCALED E N G I N E E R I N G AND LEGIBLE C O P Y / C A L C U L A TIONS AND LEGIBLE C O P Y / C A L C U L A TIONSSEE SEP ARA TE ENGINEERI N G SUBMITT AL FOR SCALED E N G I N E E R I N G AND LEGIBLE C O P Y / C A L C U L A TIONS 7 8 3 4 5 6 2101 Carrillo Privado, Ontario, CA 91761 (909) 930-0303 Fax: (909) 930-0308 E-mail: design@signindustries.tv Web: www.signindustries.tv Page: Location: Date: Sales Rep: Client Approval: Project: Date of Approval: Drawn by: Drawing No All ideas, plans or arrangements indicated on this drawing are copyrighted and owned by Sign Industries Incorporated and shall not be reproduced, used by or disclosed to any persons, firm or corporation for any purpose whatsoever without written permission of Sign Industries Incorporated. Electrical Requirement: 120 Volts 277 Volts Luis Soria / Sign cad drafter date: 08/23/22 Paul L. 2122 BRISTOL ST, NEWPORT BEACH, CA 92660 03-26-22 L.S. 822-117 08-19-22 L.S. 08-23-22 L.S. 06-01-22 L.S. 06-13-22 L.S. 08-02-22 L.S. 08-18-22 L.S. DRIVE THRU PRE-MENU SIGN~ Qty (1) INSTALLATION ONLY Design ID#22542 G SEE SHEET 8.1 FOR FOOTING/REBAR DETAILS PRE-MENU SIGN 8.08.3 BRIGHTNESS CONTROL NOTE: PRIMARY ELECTRICAL TO SIGN LOCATIONS TO BE PROVIDED BY OTHERS. A DEDICATED CIRCUIT WITH NO SHARED NEUTRALS AND A GROUND RETURNING TO THE PANEL IS REQUIRED FOR INSTALLATION. ALL TRANSFORMERS SHALL BE, (GFI) GROUND FAULT-INTERRUPTED TRANSFORMERS. ALL SIGNS HAVE - DEDICATED BRANCH CIRCUIT - THREE WIRES : LINE, NEUTRAL, & GROUND - WIRE SIZE : MINIMUM OF 12 GA. THHN COPPER WIRE ALSO NOTE: GAUGE OF WIRE IS DETERMINED BY THE LENGTH OF RUN & AMPERAGE AS PER NEC ARTICLE 300. - GROUND WIRE MUST BE CONTINUOUS AND GO FROM THE SIGN TO THE PANELBOARD GROUND BUS. - VOLTAGE SHOULD READ NO MORE THAN 3 VOLTS BETWEEN GROUND AND NEUTRAL. - CONDUIT CAN NOT BE USED AS GROUND PATH - A UL DISCONNECT SWITCH IS IN THE SIGN OR REMOTE POWER SUPPLY -SIGN CIRCUIT MUST BE ON A LIGHTING CONTROL PANEL, ASTRONOMICAL TIME CLOCK OR PHOTO CELL ALONG W/ 24 HR TIME CLOCK - POWER TO SIGN MUST BE DONE BY A LICENSED ELECTRICIAN OR ELECTRICAL CONTRACTOR. This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. This includes proper grounding and bonding of the sign. REQUIREMENTS FOR ELECTRICAL ILLUMINATION: ____ Dedicated ____ Amp Circuit at _____ Volts201201 7 8 3 4 5 6 2101 Carrillo Privado, Ontario, CA 91761 (909) 930-0303 Fax: (909) 930-0308 E-mail: design@signindustries.tv Web: www.signindustries.tv Page: Location: Date: Sales Rep: Client Approval: Project: Date of Approval: Drawn by: Drawing No All ideas, plans or arrangements indicated on this drawing are copyrighted and owned by Sign Industries Incorporated and shall not be reproduced, used by or disclosed to any persons, firm or corporation for any purpose whatsoever without written permission of Sign Industries Incorporated. Electrical Requirement: 120 Volts 277 Volts Luis Soria / Sign cad drafter date: 08/23/22 Paul L. 2122 BRISTOL ST, NEWPORT BEACH, CA 92660 03-26-22 L.S. 822-117 08-19-22 L.S. 08-23-22 L.S. 06-01-22 L.S. 06-13-22 L.S. 08-02-22 L.S. 08-18-22 L.S. 8.1 SEE SEP ARA TE ENGINEERI N G SEE SEP ARA TE ENGINEERI N G SUBMITT AL FOR SCALED E N G I N E E R I N G SUBMITT AL FOR SCALED E N G I N E E R I N G AND LEGIBLE C O P Y / C A L C U L A TIONS AND LEGIBLE C O P Y / C A L C U L A TIONSSEE SEP ARA TE ENGINEERI N G SUBMITT AL FOR SCALED E N G I N E E R I N G AND LEGIBLE C O P Y / C A L C U L A TIONS 7 8 3 4 5 6 2101 Carrillo Privado, Ontario, CA 91761 (909) 930-0303 Fax: (909) 930-0308 E-mail: design@signindustries.tv Web: www.signindustries.tv Page: Location: Date: Sales Rep: Client Approval: Project: Date of Approval: Drawn by: Drawing No All ideas, plans or arrangements indicated on this drawing are copyrighted and owned by Sign Industries Incorporated and shall not be reproduced, used by or disclosed to any persons, firm or corporation for any purpose whatsoever without written permission of Sign Industries Incorporated. Electrical Requirement: 120 Volts 277 Volts Luis Soria / Sign cad drafter date: 08/23/22 Paul L. 2122 BRISTOL ST, NEWPORT BEACH, CA 92660 03-26-22 L.S. 822-117 08-19-22 L.S. 08-23-22 L.S. 06-01-22 L.S. 06-13-22 L.S. 08-02-22 L.S. 08-18-22 L.S. FRONT ELEVATION 1 1/2"(TYP. AT EACH PLATE) CONDUIT10' - 3 7/8"4' - 6" HOT DIPPED GALVANIZED LEVELING NUTS (12) REQUIRED STEEL BASE PLATE WELDED TO STEEL POSTS BY MFR. NATURAL GRADE OR ENGINEERED FILL NON-STRUCTURAL BASE COVER DOS AND SPEAKER CANOPY ABOVE 2" CLR.1' - 5"6' - 7 7/8"9' - 10"SIDE ELEVATION 10' - 3 7/8" DRIVE THRU CANOPY WITH DIGITAL ORDER SCREEN~ Qty (1) NTS INSTALLATION ONLY Design ID#22543 SEE SHEET 9.2 FOR FOOTING/REBAR DETAILS SEE SHEET 9.2 FOR FOOTING/REBAR DETAILS Design ID#22546 9.0 H.1 VOLUME & BRIGHTNESS CONTROL NOTE: 7 8 3 4 5 6 2101 Carrillo Privado, Ontario, CA 91761 (909) 930-0303 Fax: (909) 930-0308 E-mail: design@signindustries.tv Web: www.signindustries.tv Page: Location: Date: Sales Rep: Client Approval: Project: Date of Approval: Drawn by: Drawing No All ideas, plans or arrangements indicated on this drawing are copyrighted and owned by Sign Industries Incorporated and shall not be reproduced, used by or disclosed to any persons, firm or corporation for any purpose whatsoever without written permission of Sign Industries Incorporated. Electrical Requirement: 120 Volts 277 Volts Luis Soria / Sign cad drafter date: 08/23/22 Paul L. 2122 BRISTOL ST, NEWPORT BEACH, CA 92660 03-26-22 L.S. 822-117 08-19-22 L.S. 08-23-22 L.S. 06-01-22 L.S. 06-13-22 L.S. 08-02-22 L.S. 08-18-22 L.S. 9.1 DRIVE THRU DIGITAL ORDER SCREEN W/ POST~ Qty (1) NTS INSTALLATION ONLY Design ID#22546 SEE SHEET 9.2 FOR FOOTING/REBAR DETAILS H.2 13 VOLUME & BRIGHTNESS CONTROL NOTE: PRIMARY ELECTRICAL TO SIGN LOCATIONS TO BE PROVIDED BY OTHERS. A DEDICATED CIRCUIT WITH NO SHARED NEUTRALS AND A GROUND RETURNING TO THE PANEL IS REQUIRED FOR INSTALLATION. ALL TRANSFORMERS SHALL BE, (GFI) GROUND FAULT-INTERRUPTED TRANSFORMERS. ALL SIGNS HAVE - DEDICATED BRANCH CIRCUIT - THREE WIRES : LINE, NEUTRAL, & GROUND - WIRE SIZE : MINIMUM OF 12 GA. THHN COPPER WIRE ALSO NOTE: GAUGE OF WIRE IS DETERMINED BY THE LENGTH OF RUN & AMPERAGE AS PER NEC ARTICLE 300. - GROUND WIRE MUST BE CONTINUOUS AND GO FROM THE SIGN TO THE PANELBOARD GROUND BUS. - VOLTAGE SHOULD READ NO MORE THAN 3 VOLTS BETWEEN GROUND AND NEUTRAL. - CONDUIT CAN NOT BE USED AS GROUND PATH - A UL DISCONNECT SWITCH IS IN THE SIGN OR REMOTE POWER SUPPLY -SIGN CIRCUIT MUST BE ON A LIGHTING CONTROL PANEL, ASTRONOMICAL TIME CLOCK OR PHOTO CELL ALONG W/ 24 HR TIME CLOCK - POWER TO SIGN MUST BE DONE BY A LICENSED ELECTRICIAN OR ELECTRICAL CONTRACTOR. This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. This includes proper grounding and bonding of the sign. REQUIREMENTS FOR ELECTRICAL ILLUMINATION: ____ Dedicated ____ Amp Circuit at _____ Volts201201 7 8 3 4 5 6 2101 Carrillo Privado, Ontario, CA 91761 (909) 930-0303 Fax: (909) 930-0308 E-mail: design@signindustries.tv Web: www.signindustries.tv Page: Location: Date: Sales Rep: Client Approval: Project: Date of Approval: Drawn by: Drawing No All ideas, plans or arrangements indicated on this drawing are copyrighted and owned by Sign Industries Incorporated and shall not be reproduced, used by or disclosed to any persons, firm or corporation for any purpose whatsoever without written permission of Sign Industries Incorporated. Electrical Requirement: 120 Volts 277 Volts Luis Soria / Sign cad drafter date: 08/23/22 Paul L. 2122 BRISTOL ST, NEWPORT BEACH, CA 92660 03-26-22 L.S. 822-117 08-19-22 L.S. 08-23-22 L.S. 06-01-22 L.S. 06-13-22 L.S. 08-02-22 L.S. 08-18-22 L.S. 9.2 SEE SEP ARA TE ENGINEERI N G SEE SEP ARA TE ENGINEERI N G SUBMITT AL FOR SCALED E N G I N E E R I N G SUBMITT AL FOR SCALED E N G I N E E R I N G AND LEGIBLE C O P Y / C A L C U L A TIONS AND LEGIBLE C O P Y / C A L C U L A TIONSSEE SEP ARA TE ENGINEERI N G SUBMITT AL FOR SCALED E N G I N E E R I N G AND LEGIBLE C O P Y / C A L C U L A TIONS 7 8 3 4 5 6 2101 Carrillo Privado, Ontario, CA 91761 (909) 930-0303 Fax: (909) 930-0308 E-mail: design@signindustries.tv Web: www.signindustries.tv Page: Location: Date: Sales Rep: Client Approval: Project: Date of Approval: Drawn by: Drawing No All ideas, plans or arrangements indicated on this drawing are copyrighted and owned by Sign Industries Incorporated and shall not be reproduced, used by or disclosed to any persons, firm or corporation for any purpose whatsoever without written permission of Sign Industries Incorporated. Electrical Requirement: 120 Volts 277 Volts Luis Soria / Sign cad drafter date: 08/23/22 Paul L. 2122 BRISTOL ST, NEWPORT BEACH, CA 92660 03-26-22 L.S. 822-117 08-19-22 L.S. 08-23-22 L.S. 06-01-22 L.S. 06-13-22 L.S. 08-02-22 L.S. 08-18-22 L.S. 10.0 DRIVE THRU 5-PANEL MENU SIGN~ Qty (1) Scale: 1” = 3/4” INSTALLATION ONLY Design ID#22540 28.06 I SEE SHEET 10.1 FOR FOOTING/REBAR DETAILS VOLUME & BRIGHTNESS CONTROL NOTE: PRIMARY ELECTRICAL TO SIGN LOCATIONS TO BE PROVIDED BY OTHERS. A DEDICATED CIRCUIT WITH NO SHARED NEUTRALS AND A GROUND RETURNING TO THE PANEL IS REQUIRED FOR INSTALLATION. ALL TRANSFORMERS SHALL BE, (GFI) GROUND FAULT-INTERRUPTED TRANSFORMERS. ALL SIGNS HAVE - DEDICATED BRANCH CIRCUIT - THREE WIRES : LINE, NEUTRAL, & GROUND - WIRE SIZE : MINIMUM OF 12 GA. THHN COPPER WIRE ALSO NOTE: GAUGE OF WIRE IS DETERMINED BY THE LENGTH OF RUN & AMPERAGE AS PER NEC ARTICLE 300. - GROUND WIRE MUST BE CONTINUOUS AND GO FROM THE SIGN TO THE PANELBOARD GROUND BUS. - VOLTAGE SHOULD READ NO MORE THAN 3 VOLTS BETWEEN GROUND AND NEUTRAL. - CONDUIT CAN NOT BE USED AS GROUND PATH - A UL DISCONNECT SWITCH IS IN THE SIGN OR REMOTE POWER SUPPLY -SIGN CIRCUIT MUST BE ON A LIGHTING CONTROL PANEL, ASTRONOMICAL TIME CLOCK OR PHOTO CELL ALONG W/ 24 HR TIME CLOCK - POWER TO SIGN MUST BE DONE BY A LICENSED ELECTRICIAN OR ELECTRICAL CONTRACTOR. This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. This includes proper grounding and bonding of the sign. REQUIREMENTS FOR ELECTRICAL ILLUMINATION: ____ Dedicated ____ Amp Circuit at _____ Volts201201 7 8 3 4 5 6 2101 Carrillo Privado, Ontario, CA 91761 (909) 930-0303 Fax: (909) 930-0308 E-mail: design@signindustries.tv Web: www.signindustries.tv Page: Location: Date: Sales Rep: Client Approval: Project: Date of Approval: Drawn by: Drawing No All ideas, plans or arrangements indicated on this drawing are copyrighted and owned by Sign Industries Incorporated and shall not be reproduced, used by or disclosed to any persons, firm or corporation for any purpose whatsoever without written permission of Sign Industries Incorporated. Electrical Requirement: 120 Volts 277 Volts Luis Soria / Sign cad drafter date: 08/23/22 Paul L. 2122 BRISTOL ST, NEWPORT BEACH, CA 92660 03-26-22 L.S. 822-117 08-19-22 L.S. 08-23-22 L.S. 06-01-22 L.S. 06-13-22 L.S. 08-02-22 L.S. 08-18-22 L.S. 10.1 SEE SEP ARA TE ENGINEERI N G SEE SEP ARA TE ENGINEERI N G SUBMITT AL FOR SCALED E N G I N E E R I N G SUBMITT AL FOR SCALED E N G I N E E R I N G AND LEGIBLE C O P Y / C A L C U L A TIONS AND LEGIBLE C O P Y / C A L C U L A TIONSSEE SEP ARA TE ENGINEERI N G SUBMITT AL FOR SCALED E N G I N E E R I N G AND LEGIBLE C O P Y / C A L C U L A TIONS 7 8 3 4 5 6 2101 Carrillo Privado, Ontario, CA 91761 (909) 930-0303 Fax: (909) 930-0308 E-mail: design@signindustries.tv Web: www.signindustries.tv Page: Location: Date: Sales Rep: Client Approval: Project: Date of Approval: Drawn by: Drawing No All ideas, plans or arrangements indicated on this drawing are copyrighted and owned by Sign Industries Incorporated and shall not be reproduced, used by or disclosed to any persons, firm or corporation for any purpose whatsoever without written permission of Sign Industries Incorporated. Electrical Requirement: 120 Volts 277 Volts Luis Soria / Sign cad drafter date: 08/23/22 Paul L. 2122 BRISTOL ST, NEWPORT BEACH, CA 92660 03-26-22 L.S. 822-117 08-19-22 L.S. 08-23-22 L.S. 06-01-22 L.S. 06-13-22 L.S. 08-02-22 L.S. 08-18-22 L.S. EXISTING PYLON SIGN - REPLACEMENT FACE J Scale: NTS EXISTING PYLON SIGN - PROPOSED SIGNS Scale: NTS 8’-0” new face QTY (2) QTY (2) SPECIFICATIONS CABINET: EXISTING PYLON SIGN FACES: NEW WHITE ACRYLIC FACES GRAPHICS: “STARBUCKS LOGO": 3M #3630-76 HOLLY GREEN VINYL OVERLAY “DRIVE THRU” BLACK VINYL OVERLAY 11.019’-0”9’-0” 70 8’-0” 6’-0” 12” 12” 6’-0” new face EXISTING PYLON SIGN CONDITIONS 8’-0”2’-0”5’-0”2’-0”8’-8” 7 8 3 4 5 6 2101 Carrillo Privado, Ontario, CA 91761 (909) 930-0303 Fax: (909) 930-0308 E-mail: design@signindustries.tv Web: www.signindustries.tv Page: Location: Date: Sales Rep: Client Approval: Project: Date of Approval: Drawn by: Drawing No All ideas, plans or arrangements indicated on this drawing are copyrighted and owned by Sign Industries Incorporated and shall not be reproduced, used by or disclosed to any persons, firm or corporation for any purpose whatsoever without written permission of Sign Industries Incorporated. Electrical Requirement: 120 Volts 277 Volts Luis Soria / Sign cad drafter date: 08/23/22 Paul L. 2122 BRISTOL ST, NEWPORT BEACH, CA 92660 03-26-22 L.S. 822-117 08-19-22 L.S. 08-23-22 L.S. 06-01-22 L.S. 06-13-22 L.S. 08-02-22 L.S. 08-18-22 L.S. 2 3 1/8” THICK ALUMINUM PANEL PAINTED WHITE WITH COPY AND GRAPHICS PRINTED ON 3M WHITE REFLECTIVE VINYL RB-1 FRONT VIEW (Qty-1) SCALE: 3" = 1' - 0" 1 3/4” SQ. GALVANIZED POST 14 GA. PERFORATED 7/16” GOLES 1” O.C LOCATED ON EACH SIDE 24" 24" 20" 12" POST MOUNTED ELEV. / DIRECT BURIAL DETAIL PRIVATEPROPERTY NO TRESPASSING NO LOITERING SECTION 1008, CIVIL CODE 24" 24" K 4 12.0 7 8 3 4 5 6 2101 Carrillo Privado, Ontario, CA 91761 (909) 930-0303 Fax: (909) 930-0308 E-mail: design@signindustries.tv Web: www.signindustries.tv Page: Location: Date: Sales Rep: Client Approval: Project: Date of Approval: Drawn by: Drawing No All ideas, plans or arrangements indicated on this drawing are copyrighted and owned by Sign Industries Incorporated and shall not be reproduced, used by or disclosed to any persons, firm or corporation for any purpose whatsoever without written permission of Sign Industries Incorporated. Electrical Requirement: 120 Volts 277 Volts Luis Soria / Sign cad drafter date: 08/23/22 Paul L. 2122 BRISTOL ST, NEWPORT BEACH, CA 92660 03-26-22 L.S. 822-117 08-19-22 L.S. 08-23-22 L.S. 06-01-22 L.S. 06-13-22 L.S. 08-02-22 L.S. 08-18-22 L.S. title24.01 Billie Jo Williams Priscilla Saavedra