HomeMy WebLinkAboutPA2022-136_20220823_Plans_Final7
8
3
4
5
6
2101 Carrillo Privado, Ontario, CA 91761
(909) 930-0303 Fax: (909) 930-0308
E-mail: design@signindustries.tv
Web: www.signindustries.tv
Page:
Location:
Date:
Sales Rep:
Client Approval:
Project:
Date of Approval:
Drawn by:
Drawing No
All ideas, plans or arrangements indicated
on this drawing are copyrighted and owned
by Sign Industries Incorporated and shall not
be reproduced, used by or disclosed to any
persons, firm or corporation for any purpose
whatsoever without written permission of
Sign Industries Incorporated.
Electrical Requirement:
120 Volts 277 Volts
Luis Soria / Sign cad drafter
date: 08/23/22
Paul L.
2122 BRISTOL ST,
NEWPORT BEACH, CA 92660
03-26-22 L.S.
822-117
08-19-22 L.S.
08-23-22 L.S.
06-01-22 L.S.
06-13-22 L.S.
08-02-22 L.S.
08-18-22 L.S.
BRISTOL & BIRCH
STARBUCKS COFFEE
PROJECT: # 93058-001
STORE # 67355
2122 BRISTOL ST,
NEWPORT BEACH, CA 92660
N
VICINITY MAP
Not To Scale
48” SIREN LOGO DISC
B
A
C 48" DT ILLUM. CABINET
12" CHANNEL LETTERS
SIGN
ID SIGN TYPE QTY DIMENSIONS ILLUMINATED SIGN AREA
2
1
48” DIAM 16 SQ FT.YES
10 SQ FT.YES1’ X 9’-8”
1’-9” X 3’-11 3/4”1 YES 7 SQ FT.
D DRIVE THRU DIRECTIONAL 1 1’-3” X 2’-7”3.2 SQ FT.YES
F CLEARANCE BAR 1 NO 2.3 SQ FT.5” X 5’-6”
G PRE MENU SIGN 1 3’-5 3/8” X 2’-5 1/8”YES 8.3 SQ FT.
H.1 DRIVE THRU CANOPY 1 10’-3 7/8” X 4’-6”NO N/A
H.2 DRIVE THRU ORDER SCREEN 1 4’-1 3/4” X 3’-1 1/2”YES 1313 SQ FT
I MENU BOARD 1 3’-6 3/4” X 7’-10 1/2”YES 28.06 SQ FT
J EXISTING PYLON SIGN 1 8FT DIAM/ 1’X6 PANEL YES 70 SQ FT
K R5-1 POST AND PANEL SIGN 1 2’-0” X 2’-0”NO 4 SQ FT
L EXISTING ADDRESS NUMBERS 1 8” X 21”NO 1.2 FT
Luis Soria / Sign cad drafter
date: 08/23/22 cell:909 996 9598
CONSTRUCTION NOTES:
A. ALL WORK TO COMPLY WITH 2019 CA BUILDING CODES AND
2019 CALIFORNIA EFFICIENCY STANDARDS FOR SIGN LIGHTING.
B. A 20 AMP DEDICATED CIRCUIT FOR SIGNAGE WITH ASTRONOMICAL
TIME CLOCK CONTROL SHALL BE PROVIDED.
C. SIGN INSTALLER SHALL IDENTIFY SIGN CIRCUIT BREAKER AND UPDATE PANEL
DIRECTORY
7
8
3
4
5
6
2101 Carrillo Privado, Ontario, CA 91761
(909) 930-0303 Fax: (909) 930-0308
E-mail: design@signindustries.tv
Web: www.signindustries.tv
Page:
Location:
Date:
Sales Rep:
Client Approval:
Project:
Date of Approval:
Drawn by:
Drawing No
All ideas, plans or arrangements indicated
on this drawing are copyrighted and owned
by Sign Industries Incorporated and shall not
be reproduced, used by or disclosed to any
persons, firm or corporation for any purpose
whatsoever without written permission of
Sign Industries Incorporated.
Electrical Requirement:
120 Volts 277 Volts
Luis Soria / Sign cad drafter
date: 08/23/22
Paul L.
2122 BRISTOL ST,
NEWPORT BEACH, CA 92660
03-26-22 L.S.
822-117
08-19-22 L.S.
08-23-22 L.S.
06-01-22 L.S.
06-13-22 L.S.
08-02-22 L.S.
08-18-22 L.S.
74 FT PRIMARY FRONTAGE - FACING BIRCH ST
37 FT PRIMARY FRONTAGE - BRISTOL ST
111
48
21’-4”
55.5
N/A
48
74 FT PRIMARY FRONTAGE - FACING BIRCH ST
37 FT PRIMARY FRONTAGE - BRISTOL ST
2122 Bristol St.111 sq ft max of total sign area allowed
48in max height, 21’-4” minimum
distance between signs
55.5 sq ft of total sign area allowed
48” in max height2122 Bristol St.
CP.01
SP.1
N
SITE PLAN
SCALE: NTS1
7
8
3
4
5
6
2101 Carrillo Privado, Ontario, CA 91761
(909) 930-0303 Fax: (909) 930-0308
E-mail: design@signindustries.tv
Web: www.signindustries.tv
Page:
Location:
Date:
Sales Rep:
Client Approval:
Project:
Date of Approval:
Drawn by:
Drawing No
All ideas, plans or arrangements indicated
on this drawing are copyrighted and owned
by Sign Industries Incorporated and shall not
be reproduced, used by or disclosed to any
persons, firm or corporation for any purpose
whatsoever without written permission of
Sign Industries Incorporated.
Electrical Requirement:
120 Volts 277 Volts
Luis Soria / Sign cad drafter
date: 08/23/22
Paul L.
2122 BRISTOL ST,
NEWPORT BEACH, CA 92660
03-26-22 L.S.
822-117
08-19-22 L.S.
08-23-22 L.S.
06-01-22 L.S.
06-13-22 L.S.
08-02-22 L.S.
08-18-22 L.S.
KEY LEGEND
48” SIREN LOGO DISC
DT 5 PANEL MENU SIGN
ORDER SCREEN CANOPY
CLEARANCE BAR
D/T DIRECTIONAL
PRE MENU BOARD
48" DT ILLUM. CABINET
12" CHANNEL LETTERS
B
B
A
C
D
F
G
H.1
I
AC
A
D
F
G
H.1
I
K
H.2 DIGITAL ORDER SCREEN
H.2
EXISTING PYLON SIGNJ
J
R5-1 POST AND PANELK
K
EXISTING ADDRESS NUMBERSL
L
7’
7
8
3
4
5
6
2101 Carrillo Privado, Ontario, CA 91761
(909) 930-0303 Fax: (909) 930-0308
E-mail: design@signindustries.tv
Web: www.signindustries.tv
Page:
Location:
Date:
Sales Rep:
Client Approval:
Project:
Date of Approval:
Drawn by:
Drawing No
All ideas, plans or arrangements indicated
on this drawing are copyrighted and owned
by Sign Industries Incorporated and shall not
be reproduced, used by or disclosed to any
persons, firm or corporation for any purpose
whatsoever without written permission of
Sign Industries Incorporated.
Electrical Requirement:
120 Volts 277 Volts
Luis Soria / Sign cad drafter
date: 08/23/22
Paul L.
2122 BRISTOL ST,
NEWPORT BEACH, CA 92660
03-26-22 L.S.
822-117
08-19-22 L.S.
08-23-22 L.S.
06-01-22 L.S.
06-13-22 L.S.
08-02-22 L.S.
08-18-22 L.S.
ELEV.1
NORTHWEST ELEVATION - FACING BIRCH STREET
SCALE: 1/8" = 1' - 0"1
NORTHEAST ELEVATION - FACING BRISTOL STREET
SCALE: 1/8" = 1' - 0"2
KEY LEGEND
48” SIREN LOGO DISC
B
A
C 48" DT ILLUM. CABINET
12" CHANNEL LETTERS
15'-9"15'-9"A
4'-0"EQ EQ
12'-11"C L
9'-8"EQ EQ
48"
1'-9"
EQ
EQ
C
4'-0"EQ EQ
A
12'-11"C L
1'-0"B
EQ
EQ
74'-0" PRIMARY FRONTAGE
37'-0" SECONDARY FRONTAGE
21’-4 1/2”26’-1 1/4”
7’-0”
7’-0”
L EXISTING
ADDRESS NUMBERS
L
L EXISTING ADDRESS NUMBERS TO BE
REPAINTED BLACK
2122
8”
21”
7
8
3
4
5
6
2101 Carrillo Privado, Ontario, CA 91761
(909) 930-0303 Fax: (909) 930-0308
E-mail: design@signindustries.tv
Web: www.signindustries.tv
Page:
Location:
Date:
Sales Rep:
Client Approval:
Project:
Date of Approval:
Drawn by:
Drawing No
All ideas, plans or arrangements indicated
on this drawing are copyrighted and owned
by Sign Industries Incorporated and shall not
be reproduced, used by or disclosed to any
persons, firm or corporation for any purpose
whatsoever without written permission of
Sign Industries Incorporated.
Electrical Requirement:
120 Volts 277 Volts
Luis Soria / Sign cad drafter
date: 08/23/22
Paul L.
2122 BRISTOL ST,
NEWPORT BEACH, CA 92660
03-26-22 L.S.
822-117
08-19-22 L.S.
08-23-22 L.S.
06-01-22 L.S.
06-13-22 L.S.
08-02-22 L.S.
08-18-22 L.S.
SOUTHWEST ELEVATION - FACING PARKING LOT
SCALE: 1/8" = 1' - 0"1
ELEV.2
SOUTHEAST ELEVATION - FACING DT LANE
SCALE: 1/8" = 1' - 0"2
L.S.
7
8
3
4
5
6
2101 Carrillo Privado, Ontario, CA 91761
(909) 930-0303 Fax: (909) 930-0308
E-mail: design@signindustries.tv
Web: www.signindustries.tv
Page:
Location:
Date:
Sales Rep:
Client Approval:
Project:
Date of Approval:
Drawn by:
Drawing No
All ideas, plans or arrangements indicated
on this drawing are copyrighted and owned
by Sign Industries Incorporated and shall not
be reproduced, used by or disclosed to any
persons, firm or corporation for any purpose
whatsoever without written permission of
Sign Industries Incorporated.
Electrical Requirement:
120 Volts 277 Volts
Luis Soria / Sign cad drafter
date: 08/23/22
Paul L.
2122 BRISTOL ST,
NEWPORT BEACH, CA 92660
03-26-22 L.S.
822-117
08-19-22 L.S.
08-23-22 L.S.
06-01-22 L.S.
06-13-22 L.S.
08-02-22 L.S.
08-18-22 L.S.
1.0
A
QTY : 2
L.S.
16
PRIMARY ELECTRICAL TO SIGN LOCATIONS TO BE PROVIDED BY OTHERS. A DEDICATED CIRCUIT
WITH NO SHARED NEUTRALS AND A GROUND RETURNING TO THE PANEL IS REQUIRED FOR INSTALLATION.
ALL TRANSFORMERS SHALL BE, (GFI) GROUND FAULT-INTERRUPTED TRANSFORMERS.
ALL SIGNS HAVE - DEDICATED BRANCH CIRCUIT
- THREE WIRES : LINE, NEUTRAL, & GROUND
- WIRE SIZE : MINIMUM OF 12 GA. THHN COPPER WIRE
ALSO NOTE: GAUGE OF WIRE IS DETERMINED BY THE LENGTH OF RUN & AMPERAGE AS PER NEC ARTICLE 300.
- GROUND WIRE MUST BE CONTINUOUS AND GO FROM THE SIGN TO THE PANELBOARD GROUND BUS.
- VOLTAGE SHOULD READ NO MORE THAN 3 VOLTS BETWEEN GROUND AND NEUTRAL.
- CONDUIT CAN NOT BE USED AS GROUND PATH
- A UL DISCONNECT SWITCH IS IN THE SIGN OR REMOTE POWER SUPPLY BO
-SIGN CIRCUIT MUST BE ON A LIGHTING CONTROL PANEL, ASTRONOMICAL TIME CLOCK OR PHOTO CELL ALONG
W/ 24 HR TIME CLOCK
- POWER TO SIGN MUST BE DONE BY A LICENSED ELECTRICIAN OR ELECTRICAL CONTRACTOR.
This sign is intended to be installed in accordance with the requirements
of Article 600 of the National Electrical Code and/or other applicable
local codes. This includes proper grounding and bonding of the sign.
REQUIREMENTS FOR ELECTRICAL ILLUMINATION:
____ Dedicated ____ Amp Circuit at _____ Volts201201
Wood Framed Wall/Stucco finish
3/8" X 5” (6 per logo)
lag bolt - threads
to fully engage &
penetrate plywood
sheathing
Minimum
5/8" [16 mm] thick
plywood sheathing
7
8
3
4
5
6
2101 Carrillo Privado, Ontario, CA 91761
(909) 930-0303 Fax: (909) 930-0308
E-mail: design@signindustries.tv
Web: www.signindustries.tv
Page:
Location:
Date:
Sales Rep:
Client Approval:
Project:
Date of Approval:
Drawn by:
Drawing No
All ideas, plans or arrangements indicated
on this drawing are copyrighted and owned
by Sign Industries Incorporated and shall not
be reproduced, used by or disclosed to any
persons, firm or corporation for any purpose
whatsoever without written permission of
Sign Industries Incorporated.
Electrical Requirement:
120 Volts 277 Volts
Luis Soria / Sign cad drafter
date: 08/23/22
Paul L.
2122 BRISTOL ST,
NEWPORT BEACH, CA 92660
03-26-22 L.S.
822-117
08-19-22 L.S.
08-23-22 L.S.
06-01-22 L.S.
06-13-22 L.S.
08-02-22 L.S.
08-18-22 L.S.
2.0
Faces letters 1/4" white acrylic with 3M day/nite perforated vinyl
overlay, with white 3M diffuser second surface.
1/4 white Acrylic Face
B
QTY - 1
TRIMLESS DAY/NITE CHANNEL LETTERS - REMOTE
10
PRIMARY ELECTRICAL TO SIGN LOCATIONS TO BE PROVIDED BY OTHERS. A DEDICATED CIRCUIT
WITH NO SHARED NEUTRALS AND A GROUND RETURNING TO THE PANEL IS REQUIRED FOR INSTALLATION.
ALL TRANSFORMERS SHALL BE, (GFI) GROUND FAULT-INTERRUPTED TRANSFORMERS.
ALL SIGNS HAVE - DEDICATED BRANCH CIRCUIT
- THREE WIRES : LINE, NEUTRAL, & GROUND
- WIRE SIZE : MINIMUM OF 12 GA. THHN COPPER WIRE
ALSO NOTE: GAUGE OF WIRE IS DETERMINED BY THE LENGTH OF RUN & AMPERAGE AS PER NEC ARTICLE 300.
- GROUND WIRE MUST BE CONTINUOUS AND GO FROM THE SIGN TO THE PANELBOARD GROUND BUS.
- VOLTAGE SHOULD READ NO MORE THAN 3 VOLTS BETWEEN GROUND AND NEUTRAL.
- CONDUIT CAN NOT BE USED AS GROUND PATH
- A UL DISCONNECT SWITCH IS IN THE SIGN OR REMOTE POWER SUPPLY BO
-SIGN CIRCUIT MUST BE ON A LIGHTING CONTROL PANEL, ASTRONOMICAL TIME CLOCK OR PHOTO CELL ALONG
W/ 24 HR TIME CLOCK
- POWER TO SIGN MUST BE DONE BY A LICENSED ELECTRICIAN OR ELECTRICAL CONTRACTOR.
This sign is intended to be installed in accordance with the requirements
of Article 600 of the National Electrical Code and/or other applicable
local codes. This includes proper grounding and bonding of the sign.
REQUIREMENTS FOR ELECTRICAL ILLUMINATION:
____ Dedicated ____ Amp Circuit at _____ Volts201201
1/4" X 3”(3 per letter)
lag bolt - threads
to fully engage &
penetrate plywood
sheathing
Minimum
5/8" [16 mm] thick
plywood sheathing
Wood Framed Wall/Stucco finish
7
8
3
4
5
6
2101 Carrillo Privado, Ontario, CA 91761
(909) 930-0303 Fax: (909) 930-0308
E-mail: design@signindustries.tv
Web: www.signindustries.tv
Page:
Location:
Date:
Sales Rep:
Client Approval:
Project:
Date of Approval:
Drawn by:
Drawing No
All ideas, plans or arrangements indicated
on this drawing are copyrighted and owned
by Sign Industries Incorporated and shall not
be reproduced, used by or disclosed to any
persons, firm or corporation for any purpose
whatsoever without written permission of
Sign Industries Incorporated.
Electrical Requirement:
120 Volts 277 Volts
Luis Soria / Sign cad drafter
date: 08/23/22
Paul L.
2122 BRISTOL ST,
NEWPORT BEACH, CA 92660
03-26-22 L.S.
822-117
08-19-22 L.S.
08-23-22 L.S.
06-01-22 L.S.
06-13-22 L.S.
08-02-22 L.S.
08-18-22 L.S.
3.0
Design ID#14099
1: Figured as illuminated center part
2: Figured as complete signage
48” Illuminated Drive-Thru w/ Right Arrow - Wall Mounted ~ Qty(1)
Scale: 3/4”= 1’
Left View 2 Front View Right View 3
Service Position View
Vertical Cross-Section View
NTS
NTS
Prism Enlighten white
6500K LED’s
Internally illuminated logo disc with Sloan Prism Enlightne white 6500k,
laid out at 1.5 modules per foot, 7” on center installed to back of disk
with self-contained power supply with U.L approved enclosure.
Power Supply
Section View at Installation Detail
3/8" X 3”
lag bolt - threads
to fully engage &
penetrate plywood
sheathing
3 1/2"
3 7/8"
[89mm]
[98mm]1'-2 1/2" [368mm]Minimum
5/8" [16 mm] thick
plywood sheathing
C 7
PRIMARY ELECTRICAL TO SIGN LOCATIONS TO BE PROVIDED BY OTHERS. A DEDICATED CIRCUIT
WITH NO SHARED NEUTRALS AND A GROUND RETURNING TO THE PANEL IS REQUIRED FOR INSTALLATION.
ALL TRANSFORMERS SHALL BE, (GFI) GROUND FAULT-INTERRUPTED TRANSFORMERS.
ALL SIGNS HAVE - DEDICATED BRANCH CIRCUIT
- THREE WIRES : LINE, NEUTRAL, & GROUND
- WIRE SIZE : MINIMUM OF 12 GA. THHN COPPER WIRE
ALSO NOTE: GAUGE OF WIRE IS DETERMINED BY THE LENGTH OF RUN & AMPERAGE AS PER NEC ARTICLE 300.
- GROUND WIRE MUST BE CONTINUOUS AND GO FROM THE SIGN TO THE PANELBOARD GROUND BUS.
- VOLTAGE SHOULD READ NO MORE THAN 3 VOLTS BETWEEN GROUND AND NEUTRAL.
- CONDUIT CAN NOT BE USED AS GROUND PATH
- A UL DISCONNECT SWITCH IS IN THE SIGN OR REMOTE POWER SUPPLY BO
-SIGN CIRCUIT MUST BE ON A LIGHTING CONTROL PANEL, ASTRONOMICAL TIME CLOCK OR PHOTO CELL ALONG
W/ 24 HR TIME CLOCK
- POWER TO SIGN MUST BE DONE BY A LICENSED ELECTRICIAN OR ELECTRICAL CONTRACTOR.
This sign is intended to be installed in accordance with the requirements
of Article 600 of the National Electrical Code and/or other applicable
local codes. This includes proper grounding and bonding of the sign.
REQUIREMENTS FOR ELECTRICAL ILLUMINATION:
____ Dedicated ____ Amp Circuit at _____ Volts201201Wood Framed Wall/Stucco finish
7
8
3
4
5
6
2101 Carrillo Privado, Ontario, CA 91761
(909) 930-0303 Fax: (909) 930-0308
E-mail: design@signindustries.tv
Web: www.signindustries.tv
Page:
Location:
Date:
Sales Rep:
Client Approval:
Project:
Date of Approval:
Drawn by:
Drawing No
All ideas, plans or arrangements indicated
on this drawing are copyrighted and owned
by Sign Industries Incorporated and shall not
be reproduced, used by or disclosed to any
persons, firm or corporation for any purpose
whatsoever without written permission of
Sign Industries Incorporated.
Electrical Requirement:
120 Volts 277 Volts
Luis Soria / Sign cad drafter
date: 08/23/22
Paul L.
2122 BRISTOL ST,
NEWPORT BEACH, CA 92660
03-26-22 L.S.
822-117
08-19-22 L.S.
08-23-22 L.S.
06-01-22 L.S.
06-13-22 L.S.
08-02-22 L.S.
08-18-22 L.S.
5.0
D/F DRIVE THRU DIRECTIONAL SIGNS~ Qty (1)
Scale: 1”= 1’
D
Side Street View 1
Front View 2 Store Side View 3
Rear View 4
Design ID#14104
Prism Enlighten white
6500K LED’s
Power Supply
Internally illuminated logo disc with Sloan Prism Enlighten white
6500k, laid out at 1.5 modules per foot, 7” on center
with self-contained power supply with U.L approved enclosure.
3.2
PRIMARY ELECTRICAL TO SIGN LOCATIONS TO BE PROVIDED BY OTHERS. A DEDICATED CIRCUIT
WITH NO SHARED NEUTRALS AND A GROUND RETURNING TO THE PANEL IS REQUIRED FOR INSTALLATION.
ALL TRANSFORMERS SHALL BE, (GFI) GROUND FAULT-INTERRUPTED TRANSFORMERS.
ALL SIGNS HAVE - DEDICATED BRANCH CIRCUIT
- THREE WIRES : LINE, NEUTRAL, & GROUND
- WIRE SIZE : MINIMUM OF 12 GA. THHN COPPER WIRE
ALSO NOTE: GAUGE OF WIRE IS DETERMINED BY THE LENGTH OF RUN & AMPERAGE AS PER NEC ARTICLE 300.
- GROUND WIRE MUST BE CONTINUOUS AND GO FROM THE SIGN TO THE PANELBOARD GROUND BUS.
- VOLTAGE SHOULD READ NO MORE THAN 3 VOLTS BETWEEN GROUND AND NEUTRAL.
- CONDUIT CAN NOT BE USED AS GROUND PATH
- A UL DISCONNECT SWITCH IS IN THE SIGN OR REMOTE POWER SUPPLY BO
-SIGN CIRCUIT MUST BE ON A LIGHTING CONTROL PANEL, ASTRONOMICAL TIME CLOCK OR PHOTO CELL ALONG
W/ 24 HR TIME CLOCK
- POWER TO SIGN MUST BE DONE BY A LICENSED ELECTRICIAN OR ELECTRICAL CONTRACTOR.
This sign is intended to be installed in accordance with the requirements
of Article 600 of the National Electrical Code and/or other applicable
local codes. This includes proper grounding and bonding of the sign.
REQUIREMENTS FOR ELECTRICAL ILLUMINATION:
____ Dedicated ____ Amp Circuit at _____ Volts201201
7
8
3
4
5
6
2101 Carrillo Privado, Ontario, CA 91761
(909) 930-0303 Fax: (909) 930-0308
E-mail: design@signindustries.tv
Web: www.signindustries.tv
Page:
Location:
Date:
Sales Rep:
Client Approval:
Project:
Date of Approval:
Drawn by:
Drawing No
All ideas, plans or arrangements indicated
on this drawing are copyrighted and owned
by Sign Industries Incorporated and shall not
be reproduced, used by or disclosed to any
persons, firm or corporation for any purpose
whatsoever without written permission of
Sign Industries Incorporated.
Electrical Requirement:
120 Volts 277 Volts
Luis Soria / Sign cad drafter
date: 08/23/22
Paul L.
2122 BRISTOL ST,
NEWPORT BEACH, CA 92660
03-26-22 L.S.
822-117
08-19-22 L.S.
08-23-22 L.S.
06-01-22 L.S.
06-13-22 L.S.
08-02-22 L.S.
08-18-22 L.S.
5.1
SEE SEP ARA TE ENGINEERI
N
G
SEE SEP ARA TE ENGINEERI
N
G
SUBMITT AL FOR SCALED
E
N
G
I
N
E
E
R
I
N
G
SUBMITT AL FOR SCALED
E
N
G
I
N
E
E
R
I
N
G
AND LEGIBLE
C
O
P
Y
/
C
A
L
C
U
L
A
TIONS
AND LEGIBLE
C
O
P
Y
/
C
A
L
C
U
L
A
TIONSSEE SEP ARA TE ENGINEERI
N
G
SUBMITT AL FOR SCALED
E
N
G
I
N
E
E
R
I
N
G
AND LEGIBLE
C
O
P
Y
/
C
A
L
C
U
L
A
TIONS
7
8
3
4
5
6
2101 Carrillo Privado, Ontario, CA 91761
(909) 930-0303 Fax: (909) 930-0308
E-mail: design@signindustries.tv
Web: www.signindustries.tv
Page:
Location:
Date:
Sales Rep:
Client Approval:
Project:
Date of Approval:
Drawn by:
Drawing No
All ideas, plans or arrangements indicated
on this drawing are copyrighted and owned
by Sign Industries Incorporated and shall not
be reproduced, used by or disclosed to any
persons, firm or corporation for any purpose
whatsoever without written permission of
Sign Industries Incorporated.
Electrical Requirement:
120 Volts 277 Volts
Luis Soria / Sign cad drafter
date: 08/23/22
Paul L.
2122 BRISTOL ST,
NEWPORT BEACH, CA 92660
03-26-22 L.S.
822-117
08-19-22 L.S.
08-23-22 L.S.
06-01-22 L.S.
06-13-22 L.S.
08-02-22 L.S.
08-18-22 L.S.
7.0
Design ID#22544
CONCEPTUAL RENDERING
FREESTANDING -DT CLEARNANCE BAR ARROW SERIES~ Qty (1) F
5’-6”
5"
2.3
7
8
3
4
5
6
2101 Carrillo Privado, Ontario, CA 91761
(909) 930-0303 Fax: (909) 930-0308
E-mail: design@signindustries.tv
Web: www.signindustries.tv
Page:
Location:
Date:
Sales Rep:
Client Approval:
Project:
Date of Approval:
Drawn by:
Drawing No
All ideas, plans or arrangements indicated
on this drawing are copyrighted and owned
by Sign Industries Incorporated and shall not
be reproduced, used by or disclosed to any
persons, firm or corporation for any purpose
whatsoever without written permission of
Sign Industries Incorporated.
Electrical Requirement:
120 Volts 277 Volts
Luis Soria / Sign cad drafter
date: 08/23/22
Paul L.
2122 BRISTOL ST,
NEWPORT BEACH, CA 92660
03-26-22 L.S.
822-117
08-19-22 L.S.
08-23-22 L.S.
06-01-22 L.S.
06-13-22 L.S.
08-02-22 L.S.
08-18-22 L.S.
7.1
7
8
3
4
5
6
2101 Carrillo Privado, Ontario, CA 91761
(909) 930-0303 Fax: (909) 930-0308
E-mail: design@signindustries.tv
Web: www.signindustries.tv
Page:
Location:
Date:
Sales Rep:
Client Approval:
Project:
Date of Approval:
Drawn by:
Drawing No
All ideas, plans or arrangements indicated
on this drawing are copyrighted and owned
by Sign Industries Incorporated and shall not
be reproduced, used by or disclosed to any
persons, firm or corporation for any purpose
whatsoever without written permission of
Sign Industries Incorporated.
Electrical Requirement:
120 Volts 277 Volts
Luis Soria / Sign cad drafter
date: 08/23/22
Paul L.
2122 BRISTOL ST,
NEWPORT BEACH, CA 92660
03-26-22 L.S.
822-117
08-19-22 L.S.
08-23-22 L.S.
06-01-22 L.S.
06-13-22 L.S.
08-02-22 L.S.
08-18-22 L.S.
7.2
SEE SEP ARA TE ENGINEERI
N
G
SEE SEP ARA TE ENGINEERI
N
G
SUBMITT AL FOR SCALED
E
N
G
I
N
E
E
R
I
N
G
SUBMITT AL FOR SCALED
E
N
G
I
N
E
E
R
I
N
G
AND LEGIBLE
C
O
P
Y
/
C
A
L
C
U
L
A
TIONS
AND LEGIBLE
C
O
P
Y
/
C
A
L
C
U
L
A
TIONSSEE SEP ARA TE ENGINEERI
N
G
SUBMITT AL FOR SCALED
E
N
G
I
N
E
E
R
I
N
G
AND LEGIBLE
C
O
P
Y
/
C
A
L
C
U
L
A
TIONS
7
8
3
4
5
6
2101 Carrillo Privado, Ontario, CA 91761
(909) 930-0303 Fax: (909) 930-0308
E-mail: design@signindustries.tv
Web: www.signindustries.tv
Page:
Location:
Date:
Sales Rep:
Client Approval:
Project:
Date of Approval:
Drawn by:
Drawing No
All ideas, plans or arrangements indicated
on this drawing are copyrighted and owned
by Sign Industries Incorporated and shall not
be reproduced, used by or disclosed to any
persons, firm or corporation for any purpose
whatsoever without written permission of
Sign Industries Incorporated.
Electrical Requirement:
120 Volts 277 Volts
Luis Soria / Sign cad drafter
date: 08/23/22
Paul L.
2122 BRISTOL ST,
NEWPORT BEACH, CA 92660
03-26-22 L.S.
822-117
08-19-22 L.S.
08-23-22 L.S.
06-01-22 L.S.
06-13-22 L.S.
08-02-22 L.S.
08-18-22 L.S.
DRIVE THRU PRE-MENU SIGN~ Qty (1)
INSTALLATION ONLY
Design ID#22542
G
SEE SHEET 8.1
FOR FOOTING/REBAR
DETAILS
PRE-MENU SIGN
8.08.3
BRIGHTNESS CONTROL NOTE:
PRIMARY ELECTRICAL TO SIGN LOCATIONS TO BE PROVIDED BY OTHERS. A DEDICATED CIRCUIT
WITH NO SHARED NEUTRALS AND A GROUND RETURNING TO THE PANEL IS REQUIRED FOR INSTALLATION.
ALL TRANSFORMERS SHALL BE, (GFI) GROUND FAULT-INTERRUPTED TRANSFORMERS.
ALL SIGNS HAVE - DEDICATED BRANCH CIRCUIT
- THREE WIRES : LINE, NEUTRAL, & GROUND
- WIRE SIZE : MINIMUM OF 12 GA. THHN COPPER WIRE
ALSO NOTE: GAUGE OF WIRE IS DETERMINED BY THE LENGTH OF RUN & AMPERAGE AS PER NEC ARTICLE 300.
- GROUND WIRE MUST BE CONTINUOUS AND GO FROM THE SIGN TO THE PANELBOARD GROUND BUS.
- VOLTAGE SHOULD READ NO MORE THAN 3 VOLTS BETWEEN GROUND AND NEUTRAL.
- CONDUIT CAN NOT BE USED AS GROUND PATH
- A UL DISCONNECT SWITCH IS IN THE SIGN OR REMOTE POWER SUPPLY
-SIGN CIRCUIT MUST BE ON A LIGHTING CONTROL PANEL, ASTRONOMICAL TIME CLOCK OR PHOTO CELL ALONG
W/ 24 HR TIME CLOCK
- POWER TO SIGN MUST BE DONE BY A LICENSED ELECTRICIAN OR ELECTRICAL CONTRACTOR.
This sign is intended to be installed in accordance with the requirements
of Article 600 of the National Electrical Code and/or other applicable
local codes. This includes proper grounding and bonding of the sign.
REQUIREMENTS FOR ELECTRICAL ILLUMINATION:
____ Dedicated ____ Amp Circuit at _____ Volts201201
7
8
3
4
5
6
2101 Carrillo Privado, Ontario, CA 91761
(909) 930-0303 Fax: (909) 930-0308
E-mail: design@signindustries.tv
Web: www.signindustries.tv
Page:
Location:
Date:
Sales Rep:
Client Approval:
Project:
Date of Approval:
Drawn by:
Drawing No
All ideas, plans or arrangements indicated
on this drawing are copyrighted and owned
by Sign Industries Incorporated and shall not
be reproduced, used by or disclosed to any
persons, firm or corporation for any purpose
whatsoever without written permission of
Sign Industries Incorporated.
Electrical Requirement:
120 Volts 277 Volts
Luis Soria / Sign cad drafter
date: 08/23/22
Paul L.
2122 BRISTOL ST,
NEWPORT BEACH, CA 92660
03-26-22 L.S.
822-117
08-19-22 L.S.
08-23-22 L.S.
06-01-22 L.S.
06-13-22 L.S.
08-02-22 L.S.
08-18-22 L.S.
8.1
SEE SEP ARA TE ENGINEERI
N
G
SEE SEP ARA TE ENGINEERI
N
G
SUBMITT AL FOR SCALED
E
N
G
I
N
E
E
R
I
N
G
SUBMITT AL FOR SCALED
E
N
G
I
N
E
E
R
I
N
G
AND LEGIBLE C
O
P
Y
/
C
A
L
C
U
L
A
TIONS
AND LEGIBLE C
O
P
Y
/
C
A
L
C
U
L
A
TIONSSEE SEP ARA TE ENGINEERI
N
G
SUBMITT AL FOR SCALED
E
N
G
I
N
E
E
R
I
N
G
AND LEGIBLE C
O
P
Y
/
C
A
L
C
U
L
A
TIONS
7
8
3
4
5
6
2101 Carrillo Privado, Ontario, CA 91761
(909) 930-0303 Fax: (909) 930-0308
E-mail: design@signindustries.tv
Web: www.signindustries.tv
Page:
Location:
Date:
Sales Rep:
Client Approval:
Project:
Date of Approval:
Drawn by:
Drawing No
All ideas, plans or arrangements indicated
on this drawing are copyrighted and owned
by Sign Industries Incorporated and shall not
be reproduced, used by or disclosed to any
persons, firm or corporation for any purpose
whatsoever without written permission of
Sign Industries Incorporated.
Electrical Requirement:
120 Volts 277 Volts
Luis Soria / Sign cad drafter
date: 08/23/22
Paul L.
2122 BRISTOL ST,
NEWPORT BEACH, CA 92660
03-26-22 L.S.
822-117
08-19-22 L.S.
08-23-22 L.S.
06-01-22 L.S.
06-13-22 L.S.
08-02-22 L.S.
08-18-22 L.S.
FRONT ELEVATION
1 1/2"(TYP. AT EACH PLATE)
CONDUIT10' - 3 7/8"4' - 6"
HOT
DIPPED GALVANIZED
LEVELING NUTS (12)
REQUIRED
STEEL BASE PLATE
WELDED TO STEEL
POSTS BY MFR.
NATURAL GRADE
OR ENGINEERED
FILL
NON-STRUCTURAL
BASE COVER
DOS AND SPEAKER
CANOPY ABOVE
2" CLR.1'
-
5"6'
-
7
7/8"9' - 10"SIDE ELEVATION
10' - 3 7/8" DRIVE THRU CANOPY WITH DIGITAL ORDER SCREEN~ Qty (1)
NTS INSTALLATION ONLY
Design ID#22543
SEE SHEET 9.2
FOR FOOTING/REBAR
DETAILS
SEE SHEET 9.2
FOR FOOTING/REBAR
DETAILS
Design ID#22546
9.0
H.1
VOLUME & BRIGHTNESS CONTROL NOTE:
7
8
3
4
5
6
2101 Carrillo Privado, Ontario, CA 91761
(909) 930-0303 Fax: (909) 930-0308
E-mail: design@signindustries.tv
Web: www.signindustries.tv
Page:
Location:
Date:
Sales Rep:
Client Approval:
Project:
Date of Approval:
Drawn by:
Drawing No
All ideas, plans or arrangements indicated
on this drawing are copyrighted and owned
by Sign Industries Incorporated and shall not
be reproduced, used by or disclosed to any
persons, firm or corporation for any purpose
whatsoever without written permission of
Sign Industries Incorporated.
Electrical Requirement:
120 Volts 277 Volts
Luis Soria / Sign cad drafter
date: 08/23/22
Paul L.
2122 BRISTOL ST,
NEWPORT BEACH, CA 92660
03-26-22 L.S.
822-117
08-19-22 L.S.
08-23-22 L.S.
06-01-22 L.S.
06-13-22 L.S.
08-02-22 L.S.
08-18-22 L.S.
9.1
DRIVE THRU DIGITAL ORDER SCREEN W/ POST~ Qty (1)
NTS INSTALLATION ONLY
Design ID#22546
SEE SHEET 9.2
FOR FOOTING/REBAR
DETAILS
H.2
13
VOLUME & BRIGHTNESS CONTROL NOTE:
PRIMARY ELECTRICAL TO SIGN LOCATIONS TO BE PROVIDED BY OTHERS. A DEDICATED CIRCUIT
WITH NO SHARED NEUTRALS AND A GROUND RETURNING TO THE PANEL IS REQUIRED FOR INSTALLATION.
ALL TRANSFORMERS SHALL BE, (GFI) GROUND FAULT-INTERRUPTED TRANSFORMERS.
ALL SIGNS HAVE - DEDICATED BRANCH CIRCUIT
- THREE WIRES : LINE, NEUTRAL, & GROUND
- WIRE SIZE : MINIMUM OF 12 GA. THHN COPPER WIRE
ALSO NOTE: GAUGE OF WIRE IS DETERMINED BY THE LENGTH OF RUN & AMPERAGE AS PER NEC ARTICLE 300.
- GROUND WIRE MUST BE CONTINUOUS AND GO FROM THE SIGN TO THE PANELBOARD GROUND BUS.
- VOLTAGE SHOULD READ NO MORE THAN 3 VOLTS BETWEEN GROUND AND NEUTRAL.
- CONDUIT CAN NOT BE USED AS GROUND PATH
- A UL DISCONNECT SWITCH IS IN THE SIGN OR REMOTE POWER SUPPLY
-SIGN CIRCUIT MUST BE ON A LIGHTING CONTROL PANEL, ASTRONOMICAL TIME CLOCK OR PHOTO CELL ALONG
W/ 24 HR TIME CLOCK
- POWER TO SIGN MUST BE DONE BY A LICENSED ELECTRICIAN OR ELECTRICAL CONTRACTOR.
This sign is intended to be installed in accordance with the requirements
of Article 600 of the National Electrical Code and/or other applicable
local codes. This includes proper grounding and bonding of the sign.
REQUIREMENTS FOR ELECTRICAL ILLUMINATION:
____ Dedicated ____ Amp Circuit at _____ Volts201201
7
8
3
4
5
6
2101 Carrillo Privado, Ontario, CA 91761
(909) 930-0303 Fax: (909) 930-0308
E-mail: design@signindustries.tv
Web: www.signindustries.tv
Page:
Location:
Date:
Sales Rep:
Client Approval:
Project:
Date of Approval:
Drawn by:
Drawing No
All ideas, plans or arrangements indicated
on this drawing are copyrighted and owned
by Sign Industries Incorporated and shall not
be reproduced, used by or disclosed to any
persons, firm or corporation for any purpose
whatsoever without written permission of
Sign Industries Incorporated.
Electrical Requirement:
120 Volts 277 Volts
Luis Soria / Sign cad drafter
date: 08/23/22
Paul L.
2122 BRISTOL ST,
NEWPORT BEACH, CA 92660
03-26-22 L.S.
822-117
08-19-22 L.S.
08-23-22 L.S.
06-01-22 L.S.
06-13-22 L.S.
08-02-22 L.S.
08-18-22 L.S.
9.2
SEE SEP ARA TE ENGINEERI
N
G
SEE SEP ARA TE ENGINEERI
N
G
SUBMITT AL FOR SCALED
E
N
G
I
N
E
E
R
I
N
G
SUBMITT AL FOR SCALED
E
N
G
I
N
E
E
R
I
N
G
AND LEGIBLE
C
O
P
Y
/
C
A
L
C
U
L
A
TIONS
AND LEGIBLE
C
O
P
Y
/
C
A
L
C
U
L
A
TIONSSEE SEP ARA TE ENGINEERI
N
G
SUBMITT AL FOR SCALED
E
N
G
I
N
E
E
R
I
N
G
AND LEGIBLE
C
O
P
Y
/
C
A
L
C
U
L
A
TIONS
7
8
3
4
5
6
2101 Carrillo Privado, Ontario, CA 91761
(909) 930-0303 Fax: (909) 930-0308
E-mail: design@signindustries.tv
Web: www.signindustries.tv
Page:
Location:
Date:
Sales Rep:
Client Approval:
Project:
Date of Approval:
Drawn by:
Drawing No
All ideas, plans or arrangements indicated
on this drawing are copyrighted and owned
by Sign Industries Incorporated and shall not
be reproduced, used by or disclosed to any
persons, firm or corporation for any purpose
whatsoever without written permission of
Sign Industries Incorporated.
Electrical Requirement:
120 Volts 277 Volts
Luis Soria / Sign cad drafter
date: 08/23/22
Paul L.
2122 BRISTOL ST,
NEWPORT BEACH, CA 92660
03-26-22 L.S.
822-117
08-19-22 L.S.
08-23-22 L.S.
06-01-22 L.S.
06-13-22 L.S.
08-02-22 L.S.
08-18-22 L.S.
10.0
DRIVE THRU 5-PANEL MENU SIGN~ Qty (1)
Scale: 1” = 3/4” INSTALLATION ONLY
Design ID#22540
28.06
I
SEE SHEET 10.1
FOR FOOTING/REBAR
DETAILS
VOLUME & BRIGHTNESS CONTROL NOTE:
PRIMARY ELECTRICAL TO SIGN LOCATIONS TO BE PROVIDED BY OTHERS. A DEDICATED CIRCUIT
WITH NO SHARED NEUTRALS AND A GROUND RETURNING TO THE PANEL IS REQUIRED FOR INSTALLATION.
ALL TRANSFORMERS SHALL BE, (GFI) GROUND FAULT-INTERRUPTED TRANSFORMERS.
ALL SIGNS HAVE - DEDICATED BRANCH CIRCUIT
- THREE WIRES : LINE, NEUTRAL, & GROUND
- WIRE SIZE : MINIMUM OF 12 GA. THHN COPPER WIRE
ALSO NOTE: GAUGE OF WIRE IS DETERMINED BY THE LENGTH OF RUN & AMPERAGE AS PER NEC ARTICLE 300.
- GROUND WIRE MUST BE CONTINUOUS AND GO FROM THE SIGN TO THE PANELBOARD GROUND BUS.
- VOLTAGE SHOULD READ NO MORE THAN 3 VOLTS BETWEEN GROUND AND NEUTRAL.
- CONDUIT CAN NOT BE USED AS GROUND PATH
- A UL DISCONNECT SWITCH IS IN THE SIGN OR REMOTE POWER SUPPLY
-SIGN CIRCUIT MUST BE ON A LIGHTING CONTROL PANEL, ASTRONOMICAL TIME CLOCK OR PHOTO CELL ALONG
W/ 24 HR TIME CLOCK
- POWER TO SIGN MUST BE DONE BY A LICENSED ELECTRICIAN OR ELECTRICAL CONTRACTOR.
This sign is intended to be installed in accordance with the requirements
of Article 600 of the National Electrical Code and/or other applicable
local codes. This includes proper grounding and bonding of the sign.
REQUIREMENTS FOR ELECTRICAL ILLUMINATION:
____ Dedicated ____ Amp Circuit at _____ Volts201201
7
8
3
4
5
6
2101 Carrillo Privado, Ontario, CA 91761
(909) 930-0303 Fax: (909) 930-0308
E-mail: design@signindustries.tv
Web: www.signindustries.tv
Page:
Location:
Date:
Sales Rep:
Client Approval:
Project:
Date of Approval:
Drawn by:
Drawing No
All ideas, plans or arrangements indicated
on this drawing are copyrighted and owned
by Sign Industries Incorporated and shall not
be reproduced, used by or disclosed to any
persons, firm or corporation for any purpose
whatsoever without written permission of
Sign Industries Incorporated.
Electrical Requirement:
120 Volts 277 Volts
Luis Soria / Sign cad drafter
date: 08/23/22
Paul L.
2122 BRISTOL ST,
NEWPORT BEACH, CA 92660
03-26-22 L.S.
822-117
08-19-22 L.S.
08-23-22 L.S.
06-01-22 L.S.
06-13-22 L.S.
08-02-22 L.S.
08-18-22 L.S.
10.1
SEE SEP ARA TE ENGINEERI
N
G
SEE SEP ARA TE ENGINEERI
N
G
SUBMITT AL FOR SCALED
E
N
G
I
N
E
E
R
I
N
G
SUBMITT AL FOR SCALED
E
N
G
I
N
E
E
R
I
N
G
AND LEGIBLE
C
O
P
Y
/
C
A
L
C
U
L
A
TIONS
AND LEGIBLE
C
O
P
Y
/
C
A
L
C
U
L
A
TIONSSEE SEP ARA TE ENGINEERI
N
G
SUBMITT AL FOR SCALED
E
N
G
I
N
E
E
R
I
N
G
AND LEGIBLE
C
O
P
Y
/
C
A
L
C
U
L
A
TIONS
7
8
3
4
5
6
2101 Carrillo Privado, Ontario, CA 91761
(909) 930-0303 Fax: (909) 930-0308
E-mail: design@signindustries.tv
Web: www.signindustries.tv
Page:
Location:
Date:
Sales Rep:
Client Approval:
Project:
Date of Approval:
Drawn by:
Drawing No
All ideas, plans or arrangements indicated
on this drawing are copyrighted and owned
by Sign Industries Incorporated and shall not
be reproduced, used by or disclosed to any
persons, firm or corporation for any purpose
whatsoever without written permission of
Sign Industries Incorporated.
Electrical Requirement:
120 Volts 277 Volts
Luis Soria / Sign cad drafter
date: 08/23/22
Paul L.
2122 BRISTOL ST,
NEWPORT BEACH, CA 92660
03-26-22 L.S.
822-117
08-19-22 L.S.
08-23-22 L.S.
06-01-22 L.S.
06-13-22 L.S.
08-02-22 L.S.
08-18-22 L.S.
EXISTING PYLON SIGN - REPLACEMENT FACE J Scale: NTS
EXISTING PYLON SIGN - PROPOSED SIGNS
Scale: NTS
8’-0” new face
QTY (2)
QTY (2)
SPECIFICATIONS
CABINET: EXISTING PYLON SIGN
FACES: NEW WHITE ACRYLIC FACES
GRAPHICS: “STARBUCKS LOGO": 3M #3630-76 HOLLY GREEN VINYL OVERLAY
“DRIVE THRU” BLACK VINYL OVERLAY
11.019’-0”9’-0”
70
8’-0”
6’-0”
12”
12”
6’-0” new face
EXISTING PYLON SIGN CONDITIONS 8’-0”2’-0”5’-0”2’-0”8’-8”
7
8
3
4
5
6
2101 Carrillo Privado, Ontario, CA 91761
(909) 930-0303 Fax: (909) 930-0308
E-mail: design@signindustries.tv
Web: www.signindustries.tv
Page:
Location:
Date:
Sales Rep:
Client Approval:
Project:
Date of Approval:
Drawn by:
Drawing No
All ideas, plans or arrangements indicated
on this drawing are copyrighted and owned
by Sign Industries Incorporated and shall not
be reproduced, used by or disclosed to any
persons, firm or corporation for any purpose
whatsoever without written permission of
Sign Industries Incorporated.
Electrical Requirement:
120 Volts 277 Volts
Luis Soria / Sign cad drafter
date: 08/23/22
Paul L.
2122 BRISTOL ST,
NEWPORT BEACH, CA 92660
03-26-22 L.S.
822-117
08-19-22 L.S.
08-23-22 L.S.
06-01-22 L.S.
06-13-22 L.S.
08-02-22 L.S.
08-18-22 L.S.
2 3
1/8” THICK ALUMINUM PANEL PAINTED WHITE
WITH COPY AND GRAPHICS
PRINTED ON 3M WHITE REFLECTIVE VINYL
RB-1 FRONT VIEW (Qty-1)
SCALE: 3" = 1' - 0"
1 3/4” SQ. GALVANIZED POST
14 GA. PERFORATED
7/16” GOLES
1” O.C LOCATED ON EACH SIDE
24"
24"
20"
12"
POST MOUNTED ELEV. /
DIRECT BURIAL DETAIL
PRIVATEPROPERTY
NO TRESPASSING
NO LOITERING
SECTION 1008, CIVIL CODE
24"
24"
K 4
12.0
7
8
3
4
5
6
2101 Carrillo Privado, Ontario, CA 91761
(909) 930-0303 Fax: (909) 930-0308
E-mail: design@signindustries.tv
Web: www.signindustries.tv
Page:
Location:
Date:
Sales Rep:
Client Approval:
Project:
Date of Approval:
Drawn by:
Drawing No
All ideas, plans or arrangements indicated
on this drawing are copyrighted and owned
by Sign Industries Incorporated and shall not
be reproduced, used by or disclosed to any
persons, firm or corporation for any purpose
whatsoever without written permission of
Sign Industries Incorporated.
Electrical Requirement:
120 Volts 277 Volts
Luis Soria / Sign cad drafter
date: 08/23/22
Paul L.
2122 BRISTOL ST,
NEWPORT BEACH, CA 92660
03-26-22 L.S.
822-117
08-19-22 L.S.
08-23-22 L.S.
06-01-22 L.S.
06-13-22 L.S.
08-02-22 L.S.
08-18-22 L.S.
title24.01
Billie Jo Williams
Priscilla Saavedra