HomeMy WebLinkAboutPA2021-013_20210528_Plans (2)BRANDON ARCHITECTS
DATE
T-1.0
PROJECT CONTACT
JEFF VAN VOORHIS, AIA
PROJECT NAME
PROJECT ADDRESS
908 W. OCEANFRONT
NEWPORT BEACH, CA 92661
OWNER INFORMATION
908 NB PROPERTY MANAGEMENT LLC
3717 EUCLID AVE.
DALLAS, TX
PROJECT STATUS
SECOND CHECK
PLAN CHECK NO.
TBD
REVISIONS
NO.
DATE
5/28/2021 HARVEY RESIDENCETITLE SHEET
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
REVISIONS
These documents are the property of BRANDON
ARCHITECTS INC., and are not to be duplicated,
altered or utilized in any ay by any other party
without the expressed authorization of
BRANDON ARCHITECTS. Any unauthorized
duplication or alteration of these documents by
any party is a violation of BRANDON
ARCHITECTS expressed common law copyright
and other property rights thereto, and is subject
to full civil liabilities and penalties. These plans
are also not to be assigned to any third party
without obtaining written authorization and
expressed permission by BRANDON
ARCHITECTS, who shall then be held harmless
and absolved of any liability regarding any use
of these documents by such third party whether
depicted or implied hereon.
7 1 SHEET LIST5SITE INFORMATION
4 AGENCIES & SERVICES
908 W. OCEANFRONT, NEWPORT BEACH CA 92661
HARVEY RESIDENCE
9 DEFERRED SUBMITTALS
8 SPECIAL INSPECTIONS 2 PROJECT DIRECTORY
3 CODE INFORMATION
6 SHORING & EXCAVATION
PROJECT STATISTICS
VICINITY MAP
11 PROJECT DESCRIPTION
10 BRANDON ARCHITECTS, INC.1. LANDSCAPE PLAN; BBQ; FIRE PIT; ACCESSORY STRUCTURES, MASONRY OR CONCRETE WALLS/FENCES; RETAINING WALLS OVER 4
FT. HIGH FROM THE BOTTOM OF THE FOUNDATION TO THE TOP OF WALL; UNDER SEPARATE SUBMITTAL (FOR H.O.A. PURPOSES).
2. POOLS, SPAS, WALLS, FENCES, PATIO COVERS AND OTHER FREESTANDING STRUCTURES REQUIRE SEPARATE REVIEWS AND
PERMITS.
3. SUBMIT SOUND ATTENUATION DESIGN FOR HVAC EQUIPMENT PER ARI STD. 275. SOUND LEVEL NOT TO EXCEED 50DBA (55DBA
WITH TIMER, 65DBA WITH TIMER AND NEIGHBORS CONSENT). LOCATION OF MEASUREMENT TO BE AT ADJACENT PROPERTY PATIO OR
OPENING.
4. FIRE SPRINKLERS REQUIRED, CONTRACTOR TO SUBMIT FIRE SPRINKLER DRAWINGS FOR ARCHITECT'S APPROVAL PRIOR TO
SUBMITTING TO CITY. OBTAIN FIRE SPRINKLER PERMIT PRIOR TO CALLING FOR ROOF SHEATHING INSPECTION.
5. A NOTICE OF INTENT TO DEMOLISH SHALL BE SENT VIA CERTIFIED MAIL TO ADJACENT PROPERTY OWNER(S). SIGNED RETURN
RECEIPT MUST BE PROVIDED TO THE BUILDING DIVISION AT THE TIME OF PERMIT ISSUANCE. DEMOLITION MAY COMMENCE 30 DAYS
AFTER THE DATE OF NOTIFICATION PER NEWPORT BEACH MUNICIPAL CODE SECTION 15.02.120.
6. PERMIT REQUIRED FOR ALL WALLS WITHIN 3' FROM PROPERTY LINE.
7. SOLAR PV SYSTEM. MINIMUM 4 KW DC AND BATTERY SYSTEM WITH 5 KWH TO BE UNDER SEPARATE REVIEW AND PERMIT
NOTE: DEFERRED SUBMITTALS TO BE REVIEWED BY PROJECT ARCHITECT OR ENGINEER OF RECORD AND CERTIFIED PRIOR TO
SUBMITTAL TO LOCAL AGENCY FOR REVIEW.
C.N.B. NOTE: BRANDON ARCHITECTS, INC. IS THE DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE OF THE PROJECT, RESPONSIBLE
FOR REVIEWING AND COORDINATING SUBMITTAL DOCUMENTS PREPARED BY OTHERS, INCLUDING PHASED AND DEFERRED SUBMITTAL
ITEMS, FOR COMPATIBILITY WITH THE DESIGN OF THE BUILDING. (NBMC 15.02.010)
CODES NBMC (NEWPORT BEACH MUNICIPAL CODE
CODES: 2019 CRC, 2019 CFC, 2019 CEC, AND 2019 CMC
CAL GREEN, NFPA
OCCUPANT LOAD 1 UNIT
OCCUPANCY CLASSIFICATION R-3/U
OCCUPANCY SEPARATION (GARAGE) 1-HR
FLOOR & FLOOR-CEILING N/A
TYPE OF CONSTRUCTION VB - SPRK'R
FIRE SPRINKLER (PER NFPA13D) YES
HEIGHT 3 LEVELS
FLOOR AREA REF.7/T-1.0
ALLOWABLE BLDG. AREA (PER CBC TBL.503) N/A
1. REF. STRUCT. SHTS. FOR SPECIAL INSPECTION BY ENGINEER OF RECORD
2. HERS VERIFICATION REQUIRED, REF. T-24 ENERGY CALCULATIONS
1. A CAL-OSHA PERMIT IS REQUIRED FOR EXCAVATIONS DEEPER THAN 5' AND FOR SHORING AND UNDERPINNING. CONTRACTOR TO
PROVIDE A COPY OF OSHA PERMIT.
2. CONTRACTOR SHALL USE THE CITY STANDARD FORM ‘30-DAY NOTICE OF INTENT TO EXCAVATE’ TO NOTIFY ADJACENT PROPERTY
OWNERS BY CERTIFIED MAIL 30 DAYS PRIOR TO STARTING EXCAVATION OR SHORING. CITY STANDARD FORM CAN BE OBTAINED AT:
HTTP://WWW.NEWPORTBEACHCA.GOV/HOME/SHOWDOCUMENT?ID=17395
DIG ALERT: 1.800.227.2600
SOUTHERN CALIFORNIA EDISON: 1.714.895.0246
SOUTHERN CALIFORNIA GAS: 1.800.427.2000
CITY WATER & SEWER: 1.949.644.3011
CITY OF NEWPORT BEACH
PUBLIC WORKS DEPT.: 1.949.644.3311
CITY OF NEWPORT BEACH PLANNING DEPT.:
GENERAL INFOMATION: 1.949.644.3200
ZONING INFORMATION: 1.949.644.3204
CITY OF NEWPORT BEACH BUILDING DEPT.:
GENERAL: 1.949.644.3275
PERMITS: 1.949.644.3288
INSPECTIONS: 1.949.644.3255
NEWPORT BEACH FIRE DEPARTMENT: 1.949.644.3106
ORANGE COUNTY HEALTH SERVICES: 1.714.834.3882
LEGAL DESCRIPTION
APN: 047 281 15
LOT 3, BLOCK 9
TRM_00234
MM_013_36-37
LOT INFORMATION
ZONED: R-1
SITE AREA: 3,652 SF
BUILDABLE AREA: 2,825 SF
TOTAL ALLOWABLE AREA: 2,825 X 2 S.F. = 5,650 SF
REQ'D. OPEN VOLUME: 2,825 X .15 = 424 SF
MAX. THIRD FLOOR ALLOWABLE: 2,825 X .15 = 424 SF
OPEN VOLUME PROVIDED: 425 SF
COMBINED THIRD FLOOR AND COVERED DECK: 2,825 X .5 = 1,412.5 SF
THIRD FLOOR AND COVERED DECK PROVIDED: 422 SF + 132 SF = 554 SF
EXISTING BUILDING INFORMATION
EXISTING SINGLE FAMILY W/ GARAGE TO BE DEMOLISHED
EXISTING S.F. 3,321 S.F.(3 BEDS. TTL.)
ZONING INFORMATION
FRONT SETBACK: 8 FT.
REAR SETBACK: 0 FT.
LEFT SETBACK: 3 FT.
RIGHT SETBACK: 3 FT.
BUILDABLE AREA: 2,825 S.F.
THE SUBJECT PROPERTY IS LOCATED IN NEWPORT BEACH, CA AT W OCEANFRONT, FACING THE PACIFIC OCEAN. THE LOT IS
APPROXIMATELY 40’ WIDE BY 90’ DEEP, IT IS ZONED RS-D (SINGLE UNIT RESIDENTIAL) AND IS APPROXIMATELY 3,652 S.F. THE
PROPERTY INCLUDES AN EXISTING RESIDENCE AND GARAGE. CLIENT PROPOSES TO BUILD A NEW 3 STORY SINGLE FAMILY RESIDENCE
OF APPX. 4,532 S.F. INCLUDING AN ATTACHED 3 CAR GARAGE OF APPX. 735 S.F. THE PROJECT WILL BE OF A CONTEMPORARY DESIGN,
INCLUDING BUT NOT LIMITED TO THE FOLLOWING: AMPLE INDOOR/OUTDOOR LIVING SPACES INTEGRATED WITH A MODERN ‘OPEN’
LIVING PLAN WHICH MAXIMIZES THE OCEAN VIEWS FROM LIVING SPACES AS WELL AS OUTDOOR PATIO, BALCONY, AND VIEW DECK. THE
EXTERIOR WILL BE PRIMARILY STUCCO SIDING AND METAL ROOFING, WITH ACCENTS OF WOOD, STONE AND METAL. THE HOUSE WILL
HAVE APPROXIMATELY 5 BEDROOMS, 4.5 BATHROOMS. THE FIRST FLOOR CONTAINS GENEROUS LIVING SPACE, KITCHEN AND DINING
AREA THAT ORIENTED TOWARD THE OCEAN VIEW. THE SECOND LEVEL CONSISTS OF THE MASTER BEDROOM & BATH, 4 BEDROOMS, 4
BATHROOMS AND LAUNDRY. A BONUS ROOM AND A HALF BATH BATHROOM ALONG WITH THE COVERED CABANA AND VIEW DECK ARE
LOCATED ON THE THIRD LEVEL.
TRUE NORTH PROJECT NORTH
OWNER
908 NB PROPERTY MANAGEMENT LLC
DEREK & MEGAN HARVEY
3717 EUCLID AVE.
DALLAS, TX 75205
P: 214.502.1539
CIVIL ENGINEER
FORKERT ENGINEERING &
SURVERYING, INC.
THOMAS M. RUIZ, P.E.
2231 BROOKURST ST., SUITE 203
HUNTINGTON BEACH, CA 92646
P: 714.963.6793
LANDSCAPE DESIGNER
TBD
ARCHITECT
BRANDON ARCHITECTS, INC.
CHRISTOPHER BRANDON, AIA PRINCIPAL
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
P:714.754.4040
WWW.BRANDONARCHITECTS.COM
STRUCTURAL ENGINEER
FMH ENGINEERING, INC.
FADY HAKIM, PE
410 GODDARD SUITE 200
IRVINE, CA 92618
P: 949.245.8000
WWW.FMHENGINEERING.COM
INTERIOR DESIGNER
BLACKBNAD DESIGN
MARKY MEEK
3198 AIRPORT LOOP STUDIO E
COSTA MESA, CA 92626
T. 949.872.2234
F. 949.872.2747
WWW.BLACKBANDDESIGN.COM
ENERGY CONSULTANT
CARLY NOBLE
ENERGY CODE WORKS, INC.
2600 MICHELSON DR., SUITE 1700
IRVINE, CA 92612
P: 800.700.0131
GENERAL CONTRACTOR
ANDREW PATTERSON
PATTERSON CUSTOM HOMES
15 CORPORATE PLAZA, SUITE 150
NEWPORT BEACH, CA 92660
P: 949.723.1800
SURVEYOR
APEX LAND SURVEYING, INC.
PAUL CRAFT, LIC. NO. 8516
HUNTINGTON BEACH, CA 92646
P: 714.488.5006
F: 714.333.4440
GEOTECHNICAL ENGINEER
DAVID WORTHINGTON CEG 2124
EGA CONSULTANTS, LLC.
375-C MONTE VISTA AVE.
COSTA MESA, CA 92627
P: 949.542.9309
F: 949.642.1290
PROJECT NO. BA065.1
BALBO
A
BLVD. W.
OCEAN
FRONT
ALLEY
W.08TH ST.09TH ST.10TH ST.OUTDOOR AREA
CABANA (THIRD FLOOR COVERED) 132 sq ft
BUILDING AREA
LIVING
GARAGE
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
3-CAR GARAGE
1,717
2,377
422
4,516 sq ft
732
732 sq ft
5,248 sq ft
TITLE SHEET & GENERAL NOTES
SURVEY
GRADING/CIVIL DRAWINGS
ARCHITECTURAL SITE PLANS
3D VIEWS
PLANS
ROOF PLAN
EXTERIOR ELEVATIONS
ARCHITECTURAL SECTIONS
REFLECTED CEILING PLANS
DOORS & WINDOWS
ARCHITECTURAL DETAILS
STRUCTURAL DRAWINGS
SCHEMATIC ELECTRICAL PLANS
ENERGY SHEETS
T-1.0
T-1.1
T-1.2
SUR
C1
C2
C3
C4
C5
A-0.0
A-0.1
A-0.2
A-1.0
A-2.0
A-2.1
A-2.2
A-2.3
A-3.0
A-4.0
A-5.0
A-5.1
A-6.0
A-6.1
A-7.0
A-7.1
AD-1.0
AD-2.0
S-1
S-2
S-3
S-4
D-1
D-2
D-3
D-4
D-5
D-6
SN1
HFX1
HFX2
HFX3
E-1.0
E-2.0
T-24-a
T-24-b
T-24-c
TITLE SHEET
ARCHITECTURAL GENERAL NOTES
SUPPLEMENTAL DOCUMENTS & NOTES
SURVEY
TITLE SHEET
PRECISE GRADING PLAN
SECTIONS
EROSION CONTROL PLAN
SOIL REPORT RECOMMENDATIONS
ARCHITECTURAL SITE PLAN
SLAB EDGE PLAN
AREA PLANS
3D VIEWS
FIRST & SECOND LEVEL FLOOR PLAN
THIRD LEVEL FLOOR PLAN
FIRST & SECOND LEVEL DIMENSION PLAN
THIRD LEVEL DIMENSION PLAN
ROOF PLAN
EXTERIOR ELEVATIONS
ARCHITECTURAL SECTIONS
ARCHITECTURAL SECTIONS
REFLECTED CEILING PLANS
REFLECTED CEILING PLANS
DOOR SCHEDULE & LEGEND
WINDOW SCHEDULE & LEGEND
ARCHITECTURAL DETAILS
ARCHITECTURAL DETAILS
FOUNDATION PLAN
FIRST FLOOR FRAMING PLAN
SECOND FLOOR FRAMING PLAN
ROOR FRAMING PLAN
FOUNDATION DETAILS
FRAMING DETAILS
FRAMING DETAILS
FRAMING DETAILS
FRAMING DETAILS
FRAMING DETAILS
STRUCTURAL NOTES
HARDY FRAME
HARDY FRAME
HARDY FRAME
SCHEMATIC ELECTRICAL PLANS
SCHEMATIC ELECTRICAL PLANS
TITLE-24 COMPLIANCE REPORT
TITLE-24 COMPLIANCE REPORT
TITLE-24 COMPLIANCE REPORT
CITY OF NEWPORT BEACH
COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION
100 Civic Center Drive | P.O. Box 1768 | Newport Beach, CA 92658-8915
www.newportbeachca.gov | (949) 644-3200
ACKNOWLEDGMENT OF NO CONSTRUCTION-RELATED NOISE
ON SATURDAY OR SUNDAY IN HIGH DENSITY AREAS
On June 11, 2019, the City Council adopted an ordinance restricting
construction-related noise on Saturday in High Density Areas effective
August 12, 2019.
I acknowledge that any construction-related noise, (including, but not limited
to operating power equipment or machinery in a manner that produces noise)
is not allowed on Saturday or Sunday in High Density Areas in accordance
with Newport Beach Municipal Code 10.28.040. As the owner of the
property, I am responsible to ensure all persons working on the property
comply with this provision of the Newport Beach Municipal Code.
Project Address: _______________________________________________________
Permit Number: ________________________________________________________
Owner’s Name: ________________________________________________________
Owner’s Signature: _____________________________________________________
Contractor’s Signature: _________________________________________________
Date: _________________________________________________________________
Forms\Acknowledgment_No_Saturday_Construction_HighDensityAreas
0729-2021
908 W OCEANFRONT
DocuSign Envelope ID: BBE595F9-94EB-4344-B164-A2EF801FF97D
5/27/2021
Derek Harvey
BRANDON ARCHITECTS
DATE
T-1.1
PROJECT CONTACT
JEFF VAN VOORHIS, AIA
PROJECT NAME
PROJECT ADDRESS
908 W. OCEANFRONT
NEWPORT BEACH, CA 92661
OWNER INFORMATION
908 NB PROPERTY MANAGEMENT LLC
3717 EUCLID AVE.
DALLAS, TX
PROJECT STATUS
SECOND CHECK
PLAN CHECK NO.
TBD
REVISIONS
NO.
DATE
5/28/2021 HARVEY RESIDENCEARCHITECTURAL
GENERAL NOTES
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
REVISIONS
These documents are the property of BRANDON
ARCHITECTS INC., and are not to be duplicated,
altered or utilized in any ay by any other party
without the expressed authorization of
BRANDON ARCHITECTS. Any unauthorized
duplication or alteration of these documents by
any party is a violation of BRANDON
ARCHITECTS expressed common law copyright
and other property rights thereto, and is subject
to full civil liabilities and penalties. These plans
are also not to be assigned to any third party
without obtaining written authorization and
expressed permission by BRANDON
ARCHITECTS, who shall then be held harmless
and absolved of any liability regarding any use
of these documents by such third party whether
depicted or implied hereon.
2 GENERAL NOTES 1 CONTRACT DOCUMENT NOTES
3 ABBREVIATIONS
& AND
. ANGLE
@ AT
C.L. CENTERLINE
DIAMETER, ROUND
. PERPENDICULAR
# POUND OR NUMBER
A.B. ANCHOR BOLT
ABV. ABOVE
A/C. AIR CONDITIONING
A.C. ASPHALT CONCRETE
ACOUS ACOUSTICALA.D. AREA DRAIN
ADH. ADHESIVE
ADJ. ADJUSTABLE, ADJACENT
AL. ALUMINUM
ALT. ALTERNATE
ANOD. ANODIZED
A.P. ACCESS PANEL
APPX. APPROXIMATE
APPV'D. APPROVED
ARCH. ARCHITECTURAL,ARCHITECT
ASB. ASBESTOS
ASSY. ASSEMBLY
AUTO. AUTOMATIC
B. BATHROOM
BD. BOARD
BEL. BELOWBET. BETWEEN
BIT. BITUMINOUS
BLDG. BUILDING
BLK. BLOCK
BLK'G. BLOCKING
BM. BEAM
B.O. BY OWNER, BY OTHERS
BOT. BOTTOM
BR. BEDROOM
B.W. BACK OF WALL, BOTTOM OF WALL
CAB. CABINET
C.B. CATCH BASIN
C.B.C. CALIFORNIA BUILDING CODE
C.R.C. CALIFORNIA RESIDENTIAL CODE
CEM. CEMENT
C.G. CORNER GUARDCHAN. CHANNEL
CHG. CHANGE
C.I. CAST IRON
C.J. CONTROL / CONSTRUCT./CEILING JOINT
CLG. CEILING
CLKG. CAULKING
CLR. CLEAR, CLEARANCE
CNTR. COUNTER
CONC. CONCRETE
COND. CONDITION
CONST. CONSTRUCT, CONSTRUCTION
CORR. CORRIDOR, CORROSIVE
CTSK. COUNTER SINK, COUNTERSUNK
CTR. CENTER
DBL. DOUBLE
DECO. DECORATIVEDEPT. DEPARTMENT
DET. DETAIL
D.F. DRINKING FOUNTAIN, DOUGLAS FIR
DIA. DIAMETER
DIAG. DIAGONAL
DIM. DIMENSION
DN. DOWN
DR. DOOR
D.S. DOWNSPOUT
D.S.P. DRY STANDPIPE
DWG. DRAWING(S)
E. EXISTING, EAST, ENTRY, EACH
E.J. EXPANSION JOINT
ELEC. ELECTRIC, ELECTRICAL
ELEV. ELEVATOR
EMER. EMERGENCY ENCL. ENCLOSED, ENCLOSURE
E.P. ELECTRICAL PANEL, END POINT
EQ. EQUAL
EQV. EQUIVALENT
EQUIP. EQUIPMENT
E.W. EACH WAY
EXH. EXHAUST
EXPO. EXPOSED
EXT. EXTERIOR
E.G. EXISTING GRADE
F. FIXED
F.A. FIRE ALARM
FAC. FACTORY
F.C.O. FLOOR CLEAN OUT
F.D. FLOOR DRAIN
FDN. FOUNDATIONF.E. FIRE EXTINGUISHER
F.E.C. FIRE EXTINGUISHER CABINET
F.G. FINISH GRADE
FIX./FIXT. FIXTURE
F.J. FLOOR JOIST
F.L. FLOW LINE
FLASH. FLASHING
FLR. FLOOR
FLUOR. FLUORESCENT
F.O.C. FACE OF CONCRETE/CURB
F.O.F. FACE OF FINISH
F.O.S. FACE OF STUD / STRUCTURE / SHEATHING
F.O.M. FACE OF MASONRY
FP. FIREPLACE
F.S. FLOOR SINK, FINISH SURFACE
FT. FOOT, FEET
FTG. FOOTING FURR. FURRING
FUT. FUTURE
F.V. FIELD VERIFY
GA. GAUGE
GALV. GALVANIZED
G.B. GRAB BAR, GRADE BEAM
G.C. GENERAL CONTRACTOR
GEN. GENERAL
G.F.I. GROUND FAULT INTERRUPT
G.I. GALVANIZED IRON
G.L.B. GLU-LAM BEAM
GND. GROUND
GR. GRADE
GYP. GYPSUM
G.P. GRADE PLANE
H./HT. HIGH, HEIGHT
H.B. HOSE BIBB
H.C. HOLLOW CORE
HD. HARD, HEAD
HDR. HEADER
HDWD. HARDWOOD
HDWR. HARDWARE
H.M. HOLLOW METAL
HORIZ. HORIZONTAL
HR. HOUR
HVAC HEATING VENTILATING AIR
CONDITIONING
ABBREVIATIONS
I.D. INTERIOR DESIGNER, INSIDE DIAMETER/DIMENSION
IN. INCH
INSUL. INSULATION
INT. INTERIOR
INV. INVERT/INVERTED
JAN. JANITOR
JT. JOINT
JST. JOIST
KIT. KITCHEN
L. LOW, LINEN
L.A. LANDSCAPED AREA
LAB. LABORATORY
LAM. LAMINATED
LAV. LAVATORY
LBS. POUNDS
LFA. LOAD FROM ABOVE
L.H. LEFT HAND
LKR. LOCKER
LT. LIGHT
LUM. LUMINOUS, LUMENS
MAINT. MAINTENANCE
MAS. MASONRY
MAT. MATERIAL
MAX. MAXIMUM
M.B. METAL BOLT
M.C. MEDICINE CABINET
MECH. MECHANICAL
MEMB. MEMBRANE
MET./MTL. METAL
MFGR. MANUFACTURER
M.H. MANHOLE
MIN. MINIMUM
MIR. MIRROR
MISC. MISCELLANEOUS
M.O. MASONRY OPENING
MT. MOUNTEDMUL. MULLION
N. NEW, NORTH
NAT. NATURAL
N.I.C. NOT IN CONTRACT, CONTACT
N.G. NATURAL GRADE
NO. NUMBER
NOM. NOMINAL
N.T.S. NOT TO SCALE
O/. OVER
O.A. OVERALL
OBS. OBSCURE
O.C. ON CENTER
O.D. OUTSIDE DIAMETER, DIMENSION
O.F.D. OVERFLOW DRAIN
OFF. OFFICE OPNG. OPENING
OPP. OPPOSITE
PERIM. PERIMETER
PL. PROPERTY LINE, PLATE
P.LAM. PLASTIC LAMINATE
PLAS. PLASTER
PLUMB. PLUMBING
PLYWD. PLYWOOD
PNT. PAINT(ED)
P.O.C. POINT OF CONTACT, CONNECTION
PR. PAIR
PROJ. PROJECTION
PSL. PARALLEL STRAND LAMINATE
PT. POINT
R.A. RETURN AIR RAD. RADIUS
R.D. ROOF DRAIN
R.D.L. ROOF DRAIN LEADER
RECPT. RECEPTACLE
RECT. RECTANGLE, RECTANGULAR
REF. REFERENCE
REFR./R. REFRIGERATOR
REG. REGULAR, REGISTER
REINF. REINFORCE(D), REINFORCEMENT
REQ'D. REQUIRED
RESIL. RESILIENT
RET. RETAIN(ING), RETURN
RM. ROOM
R.O. ROUGH OPENING
R.R. ROOF RAFTER
RWD. REDWOOD
S. SOUTH
S.A. SUPPLY AIR
S.C. SOLID CORE
S.C.D. SEAT COVER DISPENSER
SCHED. SCHEDULE
S.D. SUBDRAIN, SOAP DISPENSER
SEC. SECTION
SEL. SELECT(ED)
SH. SHELF
SHT. SHEET
SHT'G. SHEATHING
SIM. SIMILAR
SIMP. SIMPSON
S.J. SOFFIT JOIST
S.S. STAINLESS STEEL
S.SK. SERVICE SINK
STA. STATION STD. STANDARD
STL. STEEL
STOR. STORAGE
STRUCT. STRUCTURE, STRUCTURAL
SUSP. SUSPEND(ED)
SYM. SYMMETRICAL
SYS. SYSTEM
T. TREAD, TRASH
T.C. TOP OF CURB
T.CL. TIME CLOCK
TEL. TELEPHONE
TEMP. TEMPERED
TER. TERRAZZO
T & G TONGUE & GROOVE
THK. THICK, THICKNESS
T.P. TOP OF PAVING T.PL. TOP OF PLATE
T.O.S. TOP OF STRUCTURE, SHEATHING, SLAB
TRANS. TRANSFORMER
T.S. TOP OF STEP
T.W. TOP OF WALL
TYP. TYPICAL
U. UNDER
U.B.C. UNIFORMBUILDING CODE
U.G. UNDERGROUND
U.L. UNDERWRITER'S LABORATORY
UNF. UNFINISHED
U.N.O. UNLESS NOTED OTHERWISE
UR. URINAL
V./VERT. VERTICAL
VENT. VENTILATION, VENTILATINGVER. VERIFY
V.T.R. VENT THROUGH ROOF
W. WEST, WIDTH, WASHER
W/. WITH
WD. WOOD
W.H. WATER HEATER
W.C. WATER CLOSET
W.I. WROUGHT IRON
WP. WATERPROOF(ING)
W.W.M. WELDED WIRE MESH
DEFINITIONS: (AS USED IN THESE SPECIFICATIONS)
OWNER SHALL MEAN: 908 NB PROPERTY MANAGEMENT LLC
ARCHITECT SHALL MEAN: BRANDON ARCHITECTS, INC., JEFF VAN VOORHIS, AIA
CONTRACTOR SHALL MEAN: LICENSED GENERAL CONTRACTOR HIRED TO PERFORM THE WORK UNDER THIS CONTRACT
SPECIFICATIONS SHALL MEAN: WRITTEN SPECIFICATIONS IN THE PLANS OR THE "PROJECT MANUAL" (IF PROVIDED FOR THIS PROJECT)
CONTRACT DOCUMENTS SHALL MEAN: WORKING DRAWINGS APPROVED FOR BUILDING PERMIT, PLUS ANY CHANGE ORDERS OR ADDENDA TO SAME.
ARCHITECTURAL GENERAL NOTES:
1. CODES/GENERAL PROVISIONS: ALL WORK, CONSTRUCTION AND MATERIALS SHALL COMPLY WITH ALL PROVISIONS OF THE APPLICABLE BUILDING CODES AND WITH OTHER RULES, REGULATIONS AND ORDINANCES GOVERNING THE PLACE OF CONSTRUCTION. IT IS THE
RESPONSIBILITY OF THE CONTRACTOR, SUB-CONTRACTORS, AND ANYONE SUPPLYING LABOR AND/OR MATERIAL TO BRING TO THE ATTENTION OF THE ARCHITECT (VERBALLY AND IN WRITING) ANY KNOWN DISCREPANCIES OR CONFLICT BETWEEN THE REQUIREMENTS OF
THESE CODES AND THE CONTRACT DOCUMENTS (DRAWINGS). THE APPLICABLE CODES SHALL INCLUDE, BUT SHALL NOT BE LIMITED TO THOSE AS LISTED IN "CODE REVIEW" BOX. (T-1.0)
ALL WORK SHALL BE PERFORMED SO AS TO COMPLY WITH ALL LEGAL AND INDUSTRY REQUIREMENTS AND STANDARDS INCLUDING THE FOLLOWING:
- THE CALIFORNIA BUILDING CODES, 2019 EDITIONS, AND ALL APPLICABLE RELATED SPECIALTY CODES.
- THE FUNCTIONALITY STANDARDS SET FORTH IN TITLE 7 OF THE CALIFORNIA CIVIL CODE (THE "RIGHT TO REPAIR ACT").
- THE CITY OF NEWPORT BEACH MUNICIPAL CODE INCLUDING ANY WORK TIME RESTRICTION AND ANY AMENDMENT TO CALIFRONIA BUILDING CODES.
- THE MANUFACTURER'S REQUIREMENTS OF RECOMMENDATIONS FOR ANY INCORPORATED PRODUCTS.
2. FEES: CONTRACTOR AND HIS SUB-CONTRACTORS SHALL OBTAIN AND PAY FOR ALL PERMITS, LICENSES, CONSTRUCTION TAXES AND FEES REQUIRED BY CITY, COUNTY AND STATE LAWS EXCEPT THE GENERAL BUILDING PLAN CHECK FEE AND REQUIRED REFUNDABLE
DEPOSITS WHICH WILL BE PAID BY THE OWNER. CONTRACTOR SHALL ARRANGE FOR ALL METER INSTALLATIONS AND PAY ALL FEES FOR SAID METERS. CONTRACTOR SHALL PROVIDE TEMPORARY TOILET FACILITIES AND EROSION CONTROL MEASURES AS REQUIRED BY STATE
AND LOCAL BUILDING CODE.
3. CONTRACTOR'S SURVEY: CONTRACTOR SHALL VISIT THE JOB SITE AND BE RESPONSIBLE FOR HAVING COMPLETE KNOWLEDGE OF EXISTING CONDITIONS. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS WITH THOSE SHOWN ON THE DRAWINGS AND SHALL VERIFY
GRADES, CONDITIONS AND DIMENSIONS PRIOR TO COMMENCING DEMOLITION AND CONSTRUCTION. CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY VERBALLY AND IN WRITING OF DISCREPANCIES BETWEEN ACTUAL CONDITIONS AND THOSE DEPICTED IN THE
CONTRACT DOCUMENTS. CONTRACTOR SHALL NOTIFY ARCHITECT IMMEDIATELY VERBALLY AND IN WRITING OF ANY DISCREPANCIES FOUND WITHIN THE DRAWINGS AND SPECIFICATIONS.
4. COORDINATION OF CONSTRUCTION: CONTRACTOR IS SOLELY RESPONSIBLE FOR THE ACCURACY OF DETAILS; FOR CONFIRMING AND COORDINATING ALL QUANTITIES AND DIMENSIONS; FOR SELECTING FABRICATION PROCESSES; FOR TECHNIQUES OF ASSEMBLY AND
PERFORMANCE OF ALL WORK IN A SAFE AND SATISFACTORY MANNER. CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF ALL WORK INCLUDING THAT OF THE SUB-CONTRACTORS. CONTRACTOR SHALL PROVIDE SUPERVISION OF THE JOB DURING ALL
PHASES OF CONSTRUCTION ACTIVITIES. A COMPETENT SUPERINTENDENT SHALL BE SELECTED BY THE CONTRACTOR AND SHALL BE IN CHARGE OF THE JOB UNTIL ITS COMPLETION. CONTRACTOR AGREES TO BIND EVERY SUB-CONTRACTOR BY THE TERMS OF THE
CONTRACT AS FAR AS SUCH TERMS ARE APPLICABLE TO THE SUB-CONTRACTOR'S WORK.
5. CLEAN-UP: ALL SUBCONTRACTORS SHALL BE RESPONSIBLE FOR THE DAILY REMOVAL OF ALL DEBRIS ACCUMULATED AS A RESULT OF THEIR OPERATIONS. ALL SCRAP DEBRIS AND OTHER EXCESS MATERIAL SHALL BE LAWFULLY REMOVED FROM THE SITE, UNLESS
OTHERWISE DIRECTED BY THE CONTRACTOR.
6. TESTS AND PERMITS: CONTRACTOR SHALL ARRANGE FOR, AND SECURE REQUIRED TESTS, PERMITS AND INSPECTIONS, AND SHALL BEAR COSTS FOR SAME.
7. GUARANTEES: CONTRACTOR SHALL GUARANTEE ALL WORK, MATERIALS AND PRODUCTS FOR ONE YEAR AFTER THE DATE OF ACCEPTANCE OF THE WORK AND CONTRACTOR SHALL REPAIR OR REPLACE, OR CAUSE TO BE REPAIRED OR REPLACED ANY OR ALL SUCH WORK
TOGETHER WITH ANY OTHER WORK WHICH MAY BE DISPLACED IN DOING SO, THAT MAY PROVE DEFECTIVE WITHIN ONE YEAR, WITHOUT ADDITIONAL EXPENSE; ORDINARY WEAR AND TEAR, UNUSUAL ABUSE OR NEGLECT IS EXCEPTED. EXCEPTIONS TO ONE YEAR GUARANTEE
ARE SPECIFIED IN OTHER SECTIONS OF THE PROJECT MANUAL OR DRAWINGS. STATE LAW, OR MANUFACTURER'S GUARANTEE SHALL GOVERN IF LENGTH AND TYPES OF GUARANTEES ARE MORE STRICT OR FOR LONGER PERIODS. IT IS UNDERSTOOD BY CONTRACTOR THAT ITIS HIS RESPONSIBILITY TO PROVIDE MATERIALS AND CONSTRUCTION WHICH WILL YIELD A REASONABLE VALUE OVER A PERIOD OF TIME WHICH MAY EXCEED THE SPECIFIED GUARANTEE AND WARRANTY PERIODS. CONTRACTOR SHALL BE RESPONSIBLE FOR A WEATHER
TIGHT BUILDING, FREE FROM DEFECTS OF MATERIALS AND WORKMANSHIP. EACH SUB-CONTRACTOR SHALL PROVIDE A WRITTEN GUARANTEE STATING THAT WORK EXECUTED BY HIM IS FREE AND WILL REMAIN FREE FROM DEFECTS OF MATERIALS AND WORKMANSHIP FOR
ONE YEAR FROM DATE OF ACCEPTANCE OF HIS WORK BY OWNER, AND THAT REPAIR AND REPLACEMENT OF SUCH DEFECTIVE WORK AND ALL OTHER WORK DAMAGED AS A RESULT THEREBY WILL BE EXECUTED IN A TIMELY MANNER AT THE CONVENIENCE OF THE OWNER AND
WITHOUT COST TO OWNER.
8. WAIVER OF LIENS: CONTRACTOR SHALL PROVIDE CERTIFIED RELEASE OF LIENS BY ALL SUBCONTRACTORS AND SUPPLIERS, OR ANYONE PROVIDING MATERIALS AND/OR LABOR AS THEY BECOME AVAILABLE.
9. ROLL OF ARCHITECT DURING CONSTRUCTION: THE ARCHITECT WILL NOT ACT AS THE OWNER'S REPRESENTATIVE DURING CONSTRUCTION. ARCHITECT WILL ADVISE AND CONSULT WITH OWNER. ARCHITECT WILL OBSERVE CONSTRUCTION PER HIS/HER AGREEMENT WITH
OWNER AND RENDER INTERPRETATIONS NECESSARY FOR THE PROPER EXECUTION OR PROGRESS OF THE WORK IN ACCORDANCE WITH THE INTENT OF THE PLANS AND SPECIFICATIONS. ARCHITECT WILL NOT BE RESPONSIBLE OR HAVE CONTROL OR CHARGE OVER THE ACTS
OR OMISSIONS, CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS, OF THE CONTRACTOR, SUB-CONTRACTORS, OR ANY OF THEIR AGENTS OR EMPLOYEES, OR ANY OTHER PERSONS PERFORMING
ANY OF THE WORK. ANY VERBAL INSTRUCTION OR AUTHORIZATION THAT IS CONFIRMED BY LETTER, MEETING NOTE, MEMORANDA, OR THE LIKE, (WITH A COPY SENT TO THE OWNER, OR THE OWNER'S REPRESENTATIVE) & THERE IS NO EXCEPTION TAKEN WITHIN (10)
CALENDAR DAYS, SHALL BE DEEMED EQUIVALENT TO RECEIPT OF WRITTEN INSTRUCTION, APPROVAL AND AUTHORIZATION FROM THE OWNER.
10. A.I.A. GENERAL CONDITIONS: THE CURRENT GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION PUBLISHED BY THE AMERICAN INSTITUTE OF ARCHITECTS SHALL APPLY AS THOUGH IT WERE PART OF THESE DOCUMENTS UNLESS SPECIFICALLY MODIFIED IN
THE OWNER/CONTRACTOR AGREEMENT. A COPY OF SAID GENERAL CONDITIONS MAY BE OBTAINED FROM THE ARCHITECT UPON REQUEST. THE NOTES CONTAINED IN THESE "GENERAL NOTES" ON THIS SHEET ARE INTENDED TO SUMMARIZE AND COMPLIMENT THE A.I.A.
GENERAL CONDITIONS. THE A.I.A. GENERAL CONDITIONS SHALL TAKE PRECEDENCE OVER THESE NOTES SHOULD A CONFLICT IN WORDING OCCUR.
11. EXTRAS: OWNER MAY ORDER EXTRA WORK OR MAKE CHANGES BY ALTERING, ADDING TO OR DEDUCTING FROM THE WORK, THE CONTRACT SUM BEING ADJUSTED TO THE MUTUAL SATISFACTION OF THE OWNER AND CONTRACTOR. BEFORE ANY CHANGES ARE BEGUN,
THE ADDED OR DEDUCTED SUM SHALL BE PRESENTED TO OWNER IN WRITING FOR APPROVAL.
12. SUBSTITUTIONS: SUBSTITUTIONS OF MATERIALS OR METHODS PROPOSED BY THE CONTRACTOR OR HIS SUB-CONTRACTORS CONTRARY TO DRAWINGS AND SPECIFICATIONS SHALL BE SUBMITTED TO ARCHITECT IN WRITING FOR APPROVAL OR DENIAL. IF MORE THAN
ONE MANUFACTURER IS SPECIFIED IN THE PLANS OR SPECIFICATIONS, IT SHALL BE THE CONTRACTOR'S OPTION TO SELECT THE ONE WHICH HE MAY DESIRE. IF MORE THAN ONE FINISH OR STYLE IS AVAILABLE IN THE ITEM SPECIFIED, CONTRACTOR SHALL BE OBLIGATED TO
NOTIFY ARCHITECT VERBALLY AND IN WRITING OF THIS FACT FOR ARCHITECT'S AND OWNER'S DECISION. WHERE THE TERM "OR EQUAL" IS USED IN DRAWINGS OR SPECS IT SHALL BE UNDERSTOOD THAT THE REFERENCE IS MADE SUBJECT TO THE RULING AND JUDGMENT
OF THE ARCHITECT AND SHALL BE SUBMITTED TO THE ARCHITECT FOR REVIEW AND APPROVAL. ACTUAL SAMPLES OF THE SUBSTITUTIONS SHALL ALSO BE SUBMITTED TO THE ARCHITECT FOR REVIEW AND APPROVAL.
13. INSURANCE: CONTRACTOR SHALL CARRY GENERAL LIABILITY INSURANCE WITH BROAD FORM PROPERTY DAMAGE ENDORSEMENT AND CONTINGENT LIABILITY ENDORSEMENT. OWNER AND ARCHITECT SHALL BE LISTED AS ADDITIONAL INSURERS UNDER THE POLICY
WITH WAIVER OF SUBROGATION. CONTRACTOR SHALL FURNISH OWNER WITH A CERTIFICATE OF INSURANCE WITH A 30 DAY NOTICE OF CANCELLATION. OWNER SHALL OBTAIN A BUILDER'S RISK POLICY WITH ARCHITECT NAMED AS AN ADDITIONAL INSURED WITH WAIVER OF
SUBROGATION.
14. SCOPE OF DRAWINGS AND SPECIFICATIONS: THESE DRAWINGS AND SPECIFICATIONS SHALL BE INTENDED TO SHOW AND DESCRIBE DETAILS FOR A CONSTRUCTIBLE BUILDING. PARTS AND DETAILS NOT FULLY SHOWN OR DESCRIBED SHALL BE DETAILED ANDEXECUTED ACCORDING TO STANDARD FIRST CLASS PRACTICE AND IN SIMILAR MANNER AND SPIRIT OF THE DETAILS WHICH ARE SHOWN ON THE DRAWINGS AND/OR DESCRIBED IN THE PROJECT MANUAL. IF CONTRACTOR OR SUB-CONTRACTOR FINDS
ANY DETAILS WHICH, IN HIS OPINION, ARE UNSOUND, UNSAFE, OR NOT WATERPROOF, IT IS HIS DUTY TO NOTIFY ARCHITECT IN WRITING OF THIS FACT. IF WORK IS PERFORMED AS DETAILED, IT WILL BE ASSUMED THAT THERE ARE NO OBJECTIONS TO THE DETAIL. ACCURACY
OF ALL DIMENSIONS SHALL BE CHECKED. NO EXTRA COMPENSATION WILL BE ALLOWED FOR DIFFERENCE BETWEEN ACTUAL DIMENSIONS AND THOSE INDICATED ON THE DRAWINGS. IN USING THESE PLAN FOR BIDDING OR CONSTRUCTION PURPOSES, ALL CONTRACTORS
ARE REQUIRED TO REVIEW AND TREAT THEM AS A WHOLE IN ORDER TO IDENTIFY ALL REQUIREMENTS THAT DIRECTLY OR INDIRECTLY AFFECT THEIR PORTION OF THE WORK, EVEN REQUIREMENTS LOCATED IN SECTIONS DESIGNATED AS APPLICABLE TO OTHER TRADES. INCASE OF CONFLICTS, THE AFFECTED CONTRACTOR IS REQUIRED TO EITHER OBTAIN DIRECTION FROM AN APPROPRIATE REPRESENTATIVE OF THE OWNER, OR OTHERWISE TO APPLY THE MORE STRINGENT STANDARD. THESE PLANS ARE INTENDED TO SET FORTH THE
REQUIREMENTS FOR CONSTRUCTION IN ONLY AN INDUSTRY-STANDARD LEVEL OF QUALITY AND DETAIL, AND THEY ARE INTENDED TO BE SUPPLEMENTED BY APPROPRIATE REQUESTS FOR CLARIFICATION AND INFORMATION. ERRORS AND OMISSIONS ARE TO BE EXPECTED
AND ANTICIPATED, AND ALL CONTRACTORS ARE REQUIRED TO CAREFULLY REVIEW THESE PLANS FOR ERRORS AND OMISSIONS AND TO BRING THESE ERRORS AND OMISSIONS TO THE ATTENTION OF A APPROPRIATE OWNER & ARCHITECT IN WRITING IN A TIMELY MANNER;
AND ANY CONTRACTOR WHO FAILS TO DO SO BEFORE BIDDING OR OTHERWISE PROCEEDING ASSUMES THE RISK OF ANY CONSEQUENCES. SCALED DIMENSIONS SHOULD BE CONSIDERED ONLY APPROXIMATE; AND IN ANY DIMENSIONS BEFORE PROCEEDING WITH ANY
AFFECTED PROCUREMENT, FABRICATION OR CONSTRUCTION. SCHEMATIC PLANS ARE INTENDED ONLY TO DEMONSTRATE THE RELATIONSHIP AMONG COMPONENT PARTS, AND NOT TO DEPICT SPECIFIC LOCATIONS (E.G. SCHEMATIC ELECTRICAL PLANS).
15. DIMENSIONS ON DRAWINGS: FIGURED DIMENSIONS SHALL BE FOLLOWED IN PREFERENCE TO SCALE, AND DETAIL DRAWINGS IN PREFERENCE TO SMALL SCALE DRAWINGS. SUB-CONTRACTOR AND CONTRACTOR SHALL CHECK ACCURACY OF ALL DIMENSIONS IN THE
FIELD PRIOR TO ANY WORK BEING CONSTRUCTED OR MATERIALS OR PRODUCTS FABRICATED OR ORDERED. SPECIFICATIONS AND WRITTEN NOTES AND SCHEDULES ON DRAWINGS SHALL BE FOLLOWED IN PREFERENCE TO INFORMATION FURNISHED IN THE FORM OF LINE
DRAWINGS. DETAILED DRAWINGS FURNISHED DURING CONSTRUCTION OR APPROVED BY CONTRACTOR OR ARCHITECT ARE TO BE CONSIDERED EXPLANATORY AND NOT AS CHANGES TO DRAWINGS AND SPECIFICATIONS. NOTES, FIGURES AND DETAILS ON SAID DRAWINGS
SHALL BE FOLLOWED AND EXECUTED AS IF PART OF THESE DOCUMENTS. DRAWINGS ARE NOT TO BE SCALED UNLESS PERMITTED BY THE ARCHITECT. DIMENSIONS SHALL GOVERN. ALL EXTERIOR DIMENSIONS ARE BASED ON NOMINAL SIZES OF MEMBERS AND ARE GIVEN
TO THE OUTER FACE OF SUCH MEMBERS, UNLESS OTHERWISE NOTED ON DRAWINGS. INTERIOR PARTITIONS ARE DIMENSIONED FROM FACE OF STRUCTURE TO FACE OF STRUCTURE UNLESS OTHERWISE NOTED ON DRAWINGS. WHERE DIMENSION IS LABELED "CLEAR" IT IS
TAKEN FROM THE FACE OF FINISH TO FACE OF FINISH OF EACH MATERIAL. PLUS OR MINUS (+/-) DIMENSIONS SHALL NOT VARY BY MORE THAN 2" WITHOUT APPROVAL BY ARCHITECT. WALL ANGLES ARE EITHER 90° OR 45° UNLESS NOTED OTHERWISE.
16. SUBMITTALS, MEETING NOTES, BULLETINS, AND MEMOS: SUBMITTALS WILL BE REVIEWED BY THE ARCHITECT, IF AT ALL, ONLY PURSUANT TO THE INDUSTRY-STANDARD PROTOCOL SET FORTH IN AIA DOCUMENT A201-2017; AND IN NO EVENT WILL THE SUBMITTAL REVIEW
PROCESS RELIEVE OR LESSEN THE SUBMITTING CONTRACTOR'S RESPONSIBILITY FOR AN INAPPROPRIATE SUBMITTAL. ARCHITECT, FROM TIME TO TIME, WILL ISSUE CONSTRUCTION NOTES OR MEMOS REGARDING CONSTRUCTION ISSUES THAT HAVE ARISEN SINCE THE
DRAWINGS AND SPECIFICATIONS WERE COMPLETED. CONTRACTOR SHALL REVIEW THESE WRITTEN DOCUMENTS AND INCORPORATE THEM INTO THE PROJECT. ANY QUESTIONS OR OBJECTIONS AS TO THE INTENT OF THE WRITTEN DOCUMENT ITEMS WILL BE BROUGHT TO
THE IMMEDIATE ATTENTION OF THE ARCHITECT FOR DISCUSSION AND OR CLARIFICATION. ANY ITEM THAT RESULTS IN A CHANGE TO THE COST OR TIMING OF THE PROJECT SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE OWNER & ARCHITECT PRIOR TOEXECUTING. CONTRACTOR SHALL SUBMIT FABRICATION SHOP DRAWINGS TO THE ARCHITECT FOR APPROVAL PRIOR TO ORDERING AND/OR FABRICATION. CONTRACTOR SHALL SUBMIT MANUFACTURER'S CUTS FOR ALL FIXTURES AND EQUIPMENT CALLED FOR ON THE
CONSTRUCTION DOCUMENTS TO ARCHITECT INCLUDING BUT NOT LIMITED TO LIGHT FIXTURES, HARDWARE, PLUMBING FIXTURES, KITCHEN EQUIPMENT, ETC. BY SUBMITTING SHOP DRAWINGS AND PRODUCT DATA, THE CONTRACTOR REPRESENTS THAT HE/SHE HAS VERIFIED
FIELD CONDITIONS, DIMENSIONS AND RELATED CONSTRUCTION AND HAS COORDINATED THE SUBMISSION CONSTRUCTION WITH THE REQUIREMENTS OF ALL OTHER RELATED WORK IN THE CONSTRUCTION DOCUMENTS. ALL SHOP DRAWINGS AND CUTS MARKED "REVIEWED"
BY ARCHITECT, ARE FOR VERIFICATION OF ADHERENCE TO THE DESIGN INTENT ONLY. THE CONTRACTOR SHALL ASSUME RESPONSIBILITY FOR ALL MEANS AND METHODS AND ERRORS AND OMISSIONS ON THEIR DRAWINGS. CONTRACTOR TO SUBMIT A COMPLETE SHOP
DRAWINGS AND OR SUBMITTAL FOR APPROVAL BEFORE COMMENCING FABRICATION AND/OR INSTALLATION OF ALL APPLICABLE ITEMS. ALL SHOP DRAWINGS DIMENSIONS SHALL BE FIELD VERIFIED, REVIEWED AND APPROVED BY CONTRACTOR BEFORE SUBMITTAL. SHOP
DRAWINGS WHICH ARE INCOMPLETE OR LACKING SUFFICIENT INFORMATION WILL BE RETURNED WITHOUT REVIEW. SUBMIT SAMPLES FOR INITIAL SELECTION PURPOSES OF ACTUAL VENEERS SHOWING A FULL RANGE OR GRAIN VARIATION, FINISH AND PATTERNS PROPOSED.
SUBMIT SAMPLES AS REQUIRED UNTIL APPROVED BY ARCHITECT. SAMPLES SHALL BE 12" X 12" MIN., ONE UNIT OF EACH TYPE AND FINISH.
17. ERRORS AND OMISSIONS: ERRORS OR OMISSIONS WHICH APPEAR ON THE DRAWINGS, IN SPECIFICATIONS OR OTHER CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT BY THE CONTRACTOR AND TO THE CONTRACTOR BY
THE SUB-CONTRACTOR IN WRITING. IN EVENT OF FAILURE OF SUB-CONTRACTOR TO GIVE SUCH WRITTEN NOTIFICATION BEFORE CONSTRUCTION OR FABRICATIONS OF THE WORK, HE WILL BE HELD RESPONSIBLE FOR THE RESULTS OF ANY SUCH ERRORS OR OMISSIONS AND
THE COSTS OF RECTIFYING SAME. HOWEVER, DRAWINGS AND SPECIFICATIONS ARE COMPLEMENTARY AND WORK CALLED FOR ON ONE AND NOT THE OTHER SHALL BE PROVIDED AS THOUGH FULLY SET FORTH IN BOTH.
18. BARRICADES: CONTRACTOR SHALL ERECT AND PROPERLY MAINTAIN AT ALL TIMES AS REQUIRED BY CONDITIONS AND PROGRESS OF THE WORK, ALL NECESSARY PROTECTIVE BARRICADES, FENCES AND OTHER SAFEGUARDS FOR THE PROTECTION OF THE WORKERS ANDTHE PUBLIC. THESE BARRICADES SHALL BE CONSTRUCTED AND BE LOCATED AS SHALL BE DETERMINED BY LOCAL AUTHORITIES AND CODES.
19. TEMPORARY BRACING: AT ALL TIMES DURING CONSTRUCTION ACTIVITIES OR ERECTION OF PROJECT OR ITS COMPONENT PARTS, PRIOR TO COMPLETION OF THE STRUCTURAL FRAME OR REPLACEMENT AND PERMANENT CONNECTION OF COMPONENT MEMBERS TO THE
STRUCTURAL FRAME, SUB-CONTRACTORS SHALL PROVIDE, INSTALL AND MAINTAIN PROPERLY DESIGNED AND CONSTRUCTED TEMPORARY BRACING OF ADEQUATE STRENGTH TO PREVENT DISLOCATION, DISTORTION, CRACKING, FALLING OFF, OR ANY OTHER DAMAGE TOWORK OR ANY OF ITS COMPONENT PARTS DUE TO FORESEEABLE NORMAL AS WELL AS NOT FORESEEABLE EXCESSIVE WIND AND EARTHQUAKE FORCES WITHOUT ADDITIONAL COST TO OWNER. CONTRACTOR AND HIS SUBCONTRACTORS SHALL, AT THEIR EXPENSE, REPLACE
OR REPAIR, AS DIRECTED, DAMAGED PORTIONS OF THEIR WORK OR COMPONENT PARTS.
20. TOXIC SUBSTANCES REMOVAL: PRIOR TO ANY WORK BEING PERFORMED, WHENEVER THERE ARE EXISTING STRUCTURES TO BE REMOVED OR ALTERED, CONTRACTOR SHALL BE RESPONSIBLE FOR THE LOCATION AND REMOVAL OF ANY TOXIC MATERIALS OR SUBSTANCES
AS REQUIRED BY THE STATE OF CALIFORNIA INCLUDING BUT NOT LIMITED TO ASBESTOS, LEAD PAINTS, MOLD, ETC. REMOVAL AND DISPOSAL SHALL FOLLOW STATE MANDATED METHODS, PROCEDURES, DOCUMENTATION AND APPLICATION REQUIREMENTS.
21. NO CHANGES ARE TO BE MADE ON THESE PLANS WITHOUT THE KNOWLEDGE OR CONSENT OF THE ARCHITECT/ ENGINEER WHOSE SIGNATURE APPEARS HERON.
22. NO FRAMING OF ANY TYPE TO BE CONCEALED PRIOR TO INSPECTION BY GOVERNING AGENCIES.
23. REFERENCES TO ANY DETAIL OR DRAWINGS IS FOR CONVENIENCE ONLY AND DOES NOT LIMIT THE APPLICATION OF SUCH DETAIL OR DRAWINGS.
24. USE 2X6 MINIMUM STUDS FOR PLUMBING WALLS
25. MAINTENANCE INFORMATION: THE BUILDER SHALL PROVIDE TO THE BUILDING OWNER AT OCCUPANCY MAINTENANCE INFORMATION FOR ALL FEATURES, MATERIALS, COMPONENTS, AND MANUFACTURED INFORMATION FOR ALL FEATURES, MATERIALS, AND COMPONENTS
AND MANUFACTURED DEVICES THAT REQUIRE ROUTINE MAINTENANCE FOR EFFICIENT OPERATION. REQUIRED ROUTINE MAINTENANCE ACTIONS SHALL BE CLEARLY STATED AND INCORPORATED ON A READILY ACCESSIBLE LABEL. THE LABEL MAY BE LIMITED TO IDENTIFYING,
BY TITLE AND/OR PUBLICATION NUMBER, THE OPERATION AND MAINTENANCE MANUAL FOR THAT PARTICULAR MODEL AND TYPE OF FEATURE, MATERIAL, COMPONENT, OR MANUFACTURED DEVICE. (SEE CALGREEN NOTES FOR ADDITIONAL REQUIREMENTS OF OPERATION &MAINTENANCE MANUAL)
26. GENERAL CONTRACTOR, CONTRACTORS, SUB-CONTRACTORS AND BUILDERS TO COORDINATE ALL ENGINEERING AND MECHANICAL DRAWINGS WITH ARCHITECTURAL DRAWINGS BEFORE PROCEEDING WITH WORK. IF DISCREPANCIES ARE APPARENTLY OBSERVED OR
INFORMATION APPARENTLY IS THOUGHT TO BE MISSING, NOTIFY ARCHITECT WITHIN 24 HOURS WITH SKETCH, DRAWING, PDF, PHOTOCOPIES WITH LEGIBLE HANDWRITTEN NOTES AND/OR WRITING (FAX, EMAIL OR CORRESPONDENCE). IF CONFLICT WITH EXISTING
CONDITIONS, PROVIDE DOCUMENTATION (PHOTOS, SKETCHES, DWGS) OF EXISTING CONDITIONS AND SUGGEST PROPOSAL(S) FOR SOLUTION (SKETCH, DRAWING, AND/OR WRITING). IN CASE OF ANY DISCREPANCIES, THE ARCHITECT IS THE SOLE INTERPRETER OF THE
CONTRACT DOCUMENTS.
27. CONTRACTOR SHALL NOTIFY ARCHITECT FOR CLARIFICATION PRIOR TO BIDDING OF ANY DISCREPANCIES BETWEEN ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS. BID SHALL BE BASED ON THE MOST STRINGENT REQUIREMENT.
28. CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT OF ANY UNEXPECTED OR UNKNOWN FIELD CONDITIONS, ERRORS, OMISSIONS, OR DISCREPANCIES IN THE DRAWINGS, PROJECT MANUAL, OR CONTRACT DOCUMENTS PRIOR TO PROCEEDING WITH THE WORK OR
SHOP FABRICATIONS.
29. CONTRACTOR SHALL PREPARE AND MAINTAIN ALL CONSTRUCTION, AND SURROUNDING AREAS, FREE OF DEBRIS OR HAZARDOUS MATERIALS AT ALL TIMES. CONTRACTOR SHALL TAKE NECESSARY PRECAUTIONS TO PREVENT DUST FROM RISING.
30. CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR AND/OR THE REPLACEMENT OF ANY ITEMS DAMAGED DURING CONSTRUCTION OR CLEAN-UP. ANY DAMAGE TO EXISTING STRUCTURES DURING THE CONSTRUCTION OR THE NEW WORK SHALL BE REPAIRED TO
EQUIVALENT OR BETTER THAN ORIGINAL CONDITION AT CONTRACTOR'S EXPENSE.
31. ALL OSHA REGULATIONS FOR CONSTRUCTION AREAS SHALL BE STRICTLY FOLLOWED. CONTRACTOR SHALL PROVIDE PROPER SAFEGUARDS DURING ALL PHASES OF CONSTRUCTION.
32. CONTRACTOR TO REMOVE, RELOCATE OR RE-ROUTE, AS NECESSARY, ELECTRICAL, TELEPHONE, WATER, SEWER, GAS OR ANY OTHER UTILITY LINES ENCOUNTERED AND SHALL COORDINATE THIS WORK WILL ALL LOCAL UTILITY COMPANIES.
33. CONTRACTOR SHALL PROVIDE TEMPORARY WEATHER PROTECTION FOR PORTIONS OF THE WORK THAT BECOME EXPOSED TO WEATHER AND SHALL BE RESPONSIBLE FOR DAMAGE CAUSED BY INSUFFICIENT PROTECTION.
34. CONTRACTOR TO OBTAIN WRITTEN APPROVAL FROM OWNER AND ARCHITECT PRIOR TO ANY CHANGES OR DEVIATION FROM CONTRACT DOCUMENTS.
35. CONTRACTOR SHALL SUBMIT IN WRITING ALL PROPOSALS FOR ADDITIONAL WORK TO THE OWNER FOR REVIEW AND APPROVAL. NO WORK IS TO PROCEED UNTIL AN AUTHORIZATION TO PROCEED; SIGNED BY THE ARCHITECT & OWNER'S REPRESENTATIVE IS RETURNED
TO THE GENERAL CONTRACTOR.
36. CONTRACTOR SHALL BE AWARE THAT SPECIFIC FIRE-RATED SEPARATION WITHIN THE BUILDING'S CONSTRUCTION IS REQUIRED BY CODE. THE USE OF SPECIFIC MATERIALS AND COMBINATION OF MATERIALS WITHIN FIRE RATED ASSEMBLIES, AS CALLED FOR ON THE
DRAWINGS AND SPECIFICATIONS, ARE FOR THE PURPOSE OF ACHIEVING THOSE REQUIRED FIRE SEPARATIONS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THAT ANY CHANGE IN MATERIAL THAT IS REQUESTED BY OR MADE BY THE CONTRACTOR AND/OR ITSSUBCONTRACTORS, FROM THOSE MATERIALS DRAWN OR SPECIFIED, DOES NOT IN ANY WAY AFFECT OR LESSEN THE REQUIRED CONSTRUCTION ASSEMBLY INTEGRITY. SPECIFIC SEQUENCES OR METHODS OF ACHIEVING FIRE RATED ASSEMBLIES REQUIRED BY A "U.L. NO."
LISTING SHALL BE FOLLOWED WITHOUT DEVIATION, UNLESS OTHERWISE NOTED OR DETAILED.
69. CONTRACTOR TO FURNISH AND INSTALL ALL BLOCKING REQUIRED FOR WALL MOUNTED OR BRACED FIXTURES, MILLWORK, SHELVES, TOILET FIXTURES, AND ACCESSORIES OR 'BY OTHER' ITEMS DESCRIBED IN INTERIOR DESIGN AND ARCHITECTURAL DRAWINGS.
BLOCKING SHALL BE CONSTRUCTED TO SUPPORT THE IMPOSED LOAD.
37. ALL MANUFACTURED ARTICLES, MATERIALS AND EQUIPMENT SHALL BE SUPPLIED, INSTALLED, CONNECTED, ERECTED, USED, CLEANED AND CONDITIONED AS DIRECTED BY THE MANUFACTURERS AND REQUIRED BY CODE.
38. PRIOR TO CONSTRUCTION, CONTRACTOR TO VERIFY/COORDINATE UTILITY REQUIREMENTS FOR ALL OWNER/VENDOR FURNISHED EQUIPMENT, FIXTURES OR APPLIANCES.
39. CONTRACTOR SHALL PROVIDE ALL NECESSARY FASTENERS, SUPPORTS, SHIMMING, FLASH PATCHING, ETC. FOR THE PROPER INSTALLATION OF SUCH ITEMS AS DIRECTED BY THE MANUFACTURERS.
40. UPON COMPLETION OF THE PROJECT, THE CONTRACTOR SHALL GIVE TO THE OWNER A COMPLETE SET OF AS-BUILT CIVIL, LANDSCAPE, ARCHITECTURAL, MECHANICAL, PLUMBING, ELECTRICAL AND FIRE PROTECTION DRAWINGS ALONG WITH THE WRITTEN GUARANTIES,
OPERATION AND MAINTENANCE MANUALS OF ALL EQUIPMENT AND FINISHES INSTALLED. THE CONTRACTOR SHALL MAINTAIN A CURRENT SET OF AS-BUILT DRAWINGS AND SPECIFICATIONS. INFORMATION SHALL BE RECORDED BY CONTRACTOR AS CONSTRUCTION
PROGRESSES AND REVIEWED FOR COMPLETENESS AT EACH REQUISITION REQUEST.
41. CONTRACTOR IS RESPONSIBLE TO THOROUGHLY VACUUM CLEAN ALL CARPETED AREAS, CLEAN ALL FLOORING, MILLWORK, LIGHT FIXTURES, GLASS, ETC. AND UNCOVER AND VACUUM OUT ALL MECHANICAL UNITES AFTER THE WORK IS COMPLETED AND MAINTAIN
CLEAN CONDITIONS THROUGH THE TENANT'S MOVE-IN.
WATERPROOFING AND DAMPPROOFING NOTES:
R406.1 CONCRETE AND MASONRY FOUNDATION DAMPPROOFING
EXCEPT WHERE REQUIRED BY SECTION R406.2 TO BE WATERPROOFED, FOUNDATION WALLS THAT RETAIN EARTH AND ENCLOSE INTERIOR
SPACES AND FLOORS BELOW GRADE SHALL BE DAMPPROOFED FROM THE HIGHER OF (A) THE TOP OF THE FOOTING OR (B) 6 INCHES (152
MM) BELOW THE TOP OF THE BASEMENT FLOOR, TO THE FINISHED GRADE. MASONRY WALLS SHALL HAVE NOT LESS THAN 3/8-INCH (9.5
MM) PORTLAND CEMENT PARGING APPLIED TO THE EXTERIOR OF THE WALL. THE PARGING SHALL BE DAMPPROOFED IN ACCORDANCE
WITH ONE OF THE FOLLOWING:
1. BITUMINOUS COATING.
2. THREE POUNDS PER SQUARE YARD (1.63 KG/M2) OF ACRYLIC MODIFIED CEMENT.
3. ONE-EIGHTH-INCH (3.2 MM) COAT OF SURFACE-BONDING CEMENT COMPLYING WITH ASTM C887.
4. ANY MATERIAL PERMITTED FOR WATERPROOFING IN SECTION R406.2.
5. OTHER APPROVED METHODS OR MATERIALS.
EXCEPTION: PARGING OF UNIT MASONRY WALLS IS NOT REQUIRED WHERE A MATERIAL IS APPROVED FOR DIRECT APPLICATION TO THE
MASONRY.CONCRETE WALLS SHALL BE DAMPPROOFED BY APPLYING ANY ONE OF THE LISTED DAMPPROOFING MATERIALS OR ANY ONE OF
THE WATERPROOFING MATERIALS LISTED IN SECTION R406.2 TO THE EXTERIOR OF THE WALL.
R406.2 CONCRETE AND MASONRY FOUNDATION WATERPROOFING
IN AREAS WHERE A HIGH WATER TABLE OR OTHER SEVERE SOIL-WATER CONDITIONS ARE KNOWN TO EXIST, EXTERIOR FOUNDATION WALLS
THAT RETAIN EARTH AND ENCLOSE INTERIOR SPACES AND FLOORS BELOW GRADE SHALL BE WATERPROOFED FROM THE HIGHER OF (A) THE
TOP OF THE FOOTING OR (B) 6 INCHES (152 MM) BELOW THE TOP OF THE BASEMENT FLOOR, TO THE FINISHED GRADE. WALLS SHALL BE
WATERPROOFED IN ACCORDANCE WITH ONE OF THE FOLLOWING:
1. TWO-PLY HOT-MOPPED FELTS.
2. FIFTY-FIVE-POUND (25 KG) ROLL ROOFING.
3. SIX-MIL (0.15 MM) POLYVINYL CHLORIDE.
4. SIX-MIL (0.15 MM) POLYETHYLENE.
5. FORTY-MIL (1 MM) POLYMER-MODIFIED ASPHALT.
6. SIXTY-MIL (1.5 MM) FLEXIBLE POLYMER CEMENT.
7. ONE-EIGHTH-INCH (3 MM) CEMENT-BASED, FIBER-REINFORCED, WATERPROOF COATING.
8. SIXTY-MIL (1.5 MM) SOLVENT-FREE LIQUID-APPLIED SYNTHETIC RUBBER.
ALL JOINTS IN MEMBRANE WATERPROOFING SHALL BE LAPPED AND SEALED WITH AN ADHESIVE COMPATIBLE WITH THE MEMBRANE.
EXCEPTION: ORGANIC-SOLVENT-BASED PRODUCTS SUCH AS HYDROCARBONS, CHLORINATED HYDROCARBONS, KETONES AND ESTERS
SHALL NOT BE USED FOR ICF WALLS WITH EXPANDED POLYSTYRENE FORM MATERIAL. USE OF PLASTIC ROOFING CEMENTS, ACRYLIC
COATINGS, LATEX COATINGS, MORTARS AND PARGINGS TO SEAL ICF WALLS IS PERMITTED. COLD-SETTING ASPHALT OR HOT ASPHALT
SHALL CONFORM TO TYPE C OF ASTM D449. HOT ASPHALT SHALL BE APPLIED AT A TEMPERATURE OF LESS THAN 200°F (93°C).
DIMENSION NOTE:
ALL DIMENSIONS ARE TO FACE OF SHEATHING (EXT. WALLS) OR FACE OF STRUCTURE (F.O.S.) TYP. U.N.O. ROUNDED TO THE NEAREST 1/8"
AND INTERIOR PARTITIONS ARE DIMENSIONED FROM FACE OF STRUCTURE TO FACE OF STRUCTURE (F.O.S.) U.N.O. - CONTACT ARCHITECT IN
WRITING FOR ANY CLARIFICATION OF NOTED DIMENSIONS, DO NOT SCALE PLANS.
ROUGH FRAMING:
ALL EXTERIOR WALLS TO BE FRAMED W/. 2X6 STUD MIN. U.N.O.USE 2X6 MINIMUM STUDS FOR PLUMBING WALLS
SECOND AND THIRD FLOOR PLYWOOD TO BE 1-1/8"
ENTIRE EXTERIOR TO BE SHEATHED WITH 1/2" PLYWOOD
DOORS AND WINDOWS WILL TYPICALLY BE RECESSED FROM EXTERIOR WALL PLANE. VERIFY ALL ROUGH OPENING DIMENSIONS WITH
DOOR AND WINDOW MFGR. ROUGH OPENING MAY NEED TO BE OVERSIZED TO ACCOUNT FOR ADDITIONAL FRAMING. SEE SHT. AD-2.0 FOR
TYP. RECESSED CONDITIONS.
DUCTS PENETRATION:
DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE SHALL BE
CONSTRUCTED OF A MINIMUM NO. 26 GAGE (0.48 MM) SHEET STEEL OR OTHER APPROVED MATERIAL AND SHALL NOT HAVE OPENINGS
INTO THE GARAGE (R302.5.2)
STAIRWAY ILLUMINATION:
1.INTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE TO ILLUMINATE THE LANDINGS AND TREADS. THE LIGHT
SOURCE SHALL BE CAPABLE OF ILLUMINATING TREADS AND LANDINGS TO LEVELS OF NOT LESS THAN 1 FOOT-CANDLE (11 LUX) AS
MEASURED AT THE CENTER OF TREADS AND LANDINGS. THERE SHALL BE A WALL SWITCH AT EACH FLOOR LEVEL TO CONTROL THE LIGHT
SOURCE WHERE THE STAIRWAY HAS SIX OR MORE RISERS. (R303.7) EXCEPTION: A SWITCH IS NOT REQUIRED WHERE REMOTE, CENTRAL OR AUTOMATIC CONTROL OF LIGHTING IS
PROVIDED.
2.EXTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE LOCATED AT THE TOP LANDING OF THE STAIRWAY.
EXTERIOR STAIRWAYS PROVIDING ACCESS TO A BASEMENT FROM THE OUTDOOR GRADE LEVEL SHALL BE PROVIDED WITH AN ARTIFICIAL
LIGHT SOURCE LOCATED AT THE BOTTOM LANDING OF THE STAIRWAY. (R303.8)
GARAGE FLOOR:
GARAGE FLOOR SURFACES SHALL BE OF APPROVED NONCOMBUSTIBLE MATERIAL.THE AREA OF FLOOR USED FOR PARKING OF
AUTOMOBILES OR OTHER VEHICLES SHALL BE SLOPED TO FACILITATE THE MOVEMENT OF LIQUIDS TO A DRAIN OR TOWARD THE MAIN
VEHICLE ENTRY DOORWAY. (R309.1)
PLUMBING:
1. ALL FIXTURES AND FITTINGS SHALL COMPLY WITH THE MAX FLOW RATE SET BY CALGREEN (CALIFORNIA GREEN BUILDING STANDARD
CODE) AND CALIFORNIA PLUMBING CODES. G.C. TO VERIFY PRIOR TO PURCHASE AND INSTALL OF ANY FIXTURE AND FITTING
2. MAX. TEMP. OF 120° TO BE APPROVED BY THE USE OF PRESSURE BALANCE OR THERMOSTATIC MIXING VALVES TYP. IN COMPLIANCE W/.
ASSE 1070/ASME A112.1070/CSA B125.70 @ SHOWERS & TUBS.3. MAX. TEMP. OF 110° TO BE APPROVED BY THE USE OF PRESSURE BALANCE OR THERMOSTATIC MIXING VALVES TYP. IN COMPLIANCE W/.
ASSE 1070/ASME A112.1070/CSA B125.70 @ BIDETS.
4. SUPPORT ALL WALL-HUNG FIXTURES WITH METAL SUPPORTING MEMBERS TO PREVENT ANY STRAIN TRANSMISSION TO THE
CONNECTIONS. FRAMING AFFIXED SUPPORTS FOR OFF-THE-FLOOR WATER CLOSETS WITH CONCEALED TANKS SHALL COMPLY WITH ASME
A112.6.2. SECURE FLUSH TANK AND SIMILAR APPURTENANCES WITH APPROVED NON-CORROSIVE SCREW OR BOLTS. (CPC 402.5)
5. THE NET AREA OF THE SHOWER ENCLOSURE SHALL BE 1,024 SQ. INCHES (7.1 SQ. FT.) OR MORE IN THE CLEAR FLOOR AREA, AND SHALL
ALSO BE CAPABLE OF ENCOMPASSING A 30-INCH DIAMETER CIRCLE. (CPC 408.6)
6. THE WATER HEATER BURNER AND BURNER-IGNITION DEVICE TO BE AT LEAST 18-INCHES ABOVE THE FLOOR, IF LOCATED IN A GARAGE
AND IN ADJACENT SPACES THAT OPEN TO THE GARAGE. FOR WATER HEATER IN THE GARAGE OR OTHER AREAS SUBJECT TO MECHANICAL
DAMAGE PROVIDE A PROTECTIVE BARRIER OR ELEVATE THE APPLIANCE TO BE OUT OF THE NORMAL PATH OF THE VEHICLE. (CPC 507.13)
7. ANCHOR OR STRAP THE WATER HEATER(S) TO RESIST HORIZ. DISPLACEMENT DUE TO THE EARTHQUAKE. STRAPPING SHOULD BE AT THE
UPPER AND LOWER ONE THIRD (1/3) POINTS OF THE APPLIANCE HEIGHT. MAINTAIN A MIN. 4-INCHES ABOVE THE CONTROLS WITH
STRAPPING AT LOWER POINT.
MATERIALS & FINISHES:
1. WALLS COVERINGS AND FLOOR OF SHOWERS AND BATHTUBS WITH A SHOWER HEAD SHALL BE OF CEMENT PLASTER, TILE, OR
APPROVED EQUAL NONABSORBENT SURFACE, TO A HEIGHT OF NOT LESS THAN 72-INCHES ABOVE THE FLOOR. PROVIDE CEMENT BOARD,
CEMENT PLASTER BACKING, OR TILE BACKBOARD FOR TILE FINISH. (CRC R307.2)
2. INSTALL MIN. 5/8" TYPE 'X' MOISTURE & MOLD RESISTANT GYPSUM WALL BOARD IN ALL BATHROOMS AND KITCHENS.
FIREPLACES:
1. FACTORY-BUILT FIREPLACES, CHIMNEYS AND ALL OF THEIR COMPONENTS SHALL BE LISTED AND INSTALLED IN ACCORDANCE WITH
THEIR LISTING AND MANUFACTURER'S INSTALLATION INSTRUCTIONS. (CRC R1004.1)
2. FACTORY BUILT WOOD BURNING FIREPLACES SHALL BE QUALIFIED AT THE U.S. EPA’S VOLUNTARY FIREPLACE PROGRAM PHASE 2
EMISSIONS LEVEL. (CRC 1004.1.1)
3. DECORATIVE SHROUDS SHALL NOT BE INSTALLED AT THE TERMINATION OF FACTORY-BUILT CHIMNEYS EXCEPT WHERE SUCH SHROUDS
ARE LISTED AND LABELED FOR USE WITH THE SPECIFIC FACTORY-BUILT CHIMNEY SYSTEM AND ARE INSTALLED IN ACCORDANCE WITH
MANUFACTURER'S INSTALLATION INSTRUCTIONS. (CRC R1005.2 & CMC 802.5.1.1 & CMC 802.5.4.3)
4. HORIZONTAL OPENINGS ARE NOT ALLOWED, FOR EXHAUST VENTS, IN WALLS CLOSER THAN 3 FEET TO A PROPERTY LINE. (TABLES R302.1
(1)&(2)). HORIZONTAL VENT CAPS SHALL BE 2 FEET CLEAR FROM PROPERTY LINES.
5. EXHAUST OPENINGS SHALL NOT BE DIRECTED ONTO WALKWAYS. (R303.5.2)
6. SOLID FUEL BURNING FIREPLACES (IF PERMISSIBLE):
A. PROVIDE A PERMANENTLY ANCHORED GASEOUS FUEL BURNING PAN TO THE FIREBOX OF A SOLID
FUEL BURNING FIREPLACE.
B. SOLID FUEL BURNING FIREPLACE MUST COMPLY WITH THE CALIFORNIA ENERGY STANDARDS MANDATORY MEASURES.
C. CHIMNEY SHALL EXTEND AT LEAST 2 FT. HIGHER THAN ANY PORTION OF THE BUILDING WITHIN 10 FT., BUT SHALL
NOT BE LESS THAN 3 FT. ABOVE THE HIGHEST POINT WHERE THE CHIMNEY PASSES THROUGH THE ROOF. (CRC R1003.9)
D. LIQUID FUELED FIREPLACES ARE NOT ALLOWED FOR INTERIOR USE.
7. ANY INSTALLED GAS FIREPLACE SHALL BE DIRECT VENT SEALED-COMBUSTION PER CAL GREEN SECTION 4.503.
POOL:
1. PROVIDE AN ALARM FOR DOORS AND WINDOWS WITH SILL HEIGHTS LESS THAN 60-INCHES ABV.F.F. OF THE DWELLING THAT FORMS A
PART OF THE POOL ENCLOSURE. THE ALARM SHALL BE LISTED AS A WATER HAZARD ENTRANCE ALARM IN ACCORDANCE WITH UL 2017.
THE DEACTIVATION SWITCH SHALL BE AT LEAST 60" ABOVE THE FLOOR IF THE RESIDENCE IS NOT REQUIRED TO BE ACCESSIBLE. (CBC 3109
& ISPSC 305.4)
2. SUCTION OUTLETS SHALL BE DESIGNED AND INSTALLED WITH SUCTION ANTIENTRAPMENT GRATE IN ACCORDANCE WITH ANSI/APSP-16
PER CBC 3109 SECTION (B) OF 115928. SUCTION ENTRAPMENT AVOIDANCE FOR POOL AND SPA SHALL BE PROVIDED IN ACCORDANCE WITH
APSP-7 PER ISPSC SECTION 310.
3. PROVIDE POWER SAFETY COVER IN COMPLIANCE WITH ASTM F1346-91 FOR POOL & SPA (CBC 3109 SECTION (3) OF 115922 & ISPSC
305).
4. POOL ENCLOSURE FENCE SHALL BE 60-INCHES MIN. ABV. FS/NG MEASURED ON THE SIDE THAT FACES AWAY FROM SWIMMING POOL W/.
MAX VERTICAL CLEARANCE OF 2-INCHES BETWEEN FS/NG AND BOTTOM OF THE FENCE/BARRIER MEASURED ON THE SIDE OF FENCE THAT
FACES AWAY FROM SWIMMING POOL. OPENING, GAP, AND VOID IN ENCLOSURE FENCE OR GATE SHALL NOT ALLOW THE PASSAGE OF 4-
INCHES DIAMETER SPHERE OR LARGER. OUTSIDE SURFACE (FACING AWAY FROM SWIMMING POOL) OF THE POOL ENCLOSURE INCLUDING
THE GATE TO BE FREE OF PROTRUSIONS, CAVITIES, OR OTHER PHYSICAL CHARACTERISTICS THAT WOULD SERVE AS HANDHOLDS OR
FOOTHOLDS WHICH COULD ENABLE A CHILD FIVE YEARS OLD OR YOUNGER TO CLIMB OVER. (CBC 3109 & ISPSC 305)
WOOD OR WOODBASED PRODUCTS NOTE:
WOOD OR WOODBASE PRODUCT SHALL BE OF A NATURAL DURABLE OR PRESERVATIVE-TREADED WOOD IN ACCORDANCE WITH AWPA U1
FOR THE SPECIES, PRODUCT, PRESERVATIVE AND END USE IN THE FOLLOWING LOCATIONS:
1. WOOD JOISTS OR THE BOTTOM OF A WOOD STRUCTURAL FLOOR WHEN CLOSER THAN 18 INCHES (457 MM) OR WOOD GIRDERS WHEN
CLOSER THAN 12 INCHES (305 MM) TO THE EXPOSED GROUND IN CRAWL SPACES OR UNEXCAVATED AREA LOCATED WITHIN THE
PERIPHERY OF THE BUILDING FOUNDATION.
2. WOOD FRAMING MEMBERS THAT REST ON CONCRETE OR MASONRY EXTERIOR FOUNDATION WALLS AND ARE LESS THAN 8 INCHES (203
MM) FROM THE EXPOSED GROUND.
3. SILLS AND SLEEPERS ON A CONCRETE OR MASONRY SLAB THAT IS IN DIRECT CONTACT WITH THE GROUND UNLESS SEPARATED FROM
SUCH SLAB BY AN IMPERVIOUS MOISTURE BARRIER.
4. THE ENDS OF WOOD GIRDERS ENTERING EXTERIOR MASONRY OR CONCRETE WALLS HAVING CLEARANCES OF LESS THAN 1/2 INCH (12.7
MM) ON TOPS, SIDES AND ENDS.
5. WOOD SIDING, SHEATHING AND WALL FRAMING ON THE EXTERIOR OF A BUILDING HAVING A CLEARANCE OF LESS THAN 6 INCHES (152
MM) FROM THE GROUND OR LESS THAN 2 INCHES (51 MM) MEASURED VERTICALLY FROM CONCRETE STEPS, PORCH SLABS, PATIO SLABS
AND SIMILAR HORIZONTAL SURFACES EXPOSED TO THE WEATHER.
6. WOOD STRUCTURAL MEMBERS SUPPORTING MOISTURE-PERMEABLE FLOORS OR ROOFS THAT ARE EXPOSED TO THE WEATHER, SUCH AS
CONCRETE OR MASONRY SLABS, UNLESS SEPARATED FROM SUCH FLOORS OR ROOFS BY AN IMPERVIOUS MOISTURE BARRIER.
7. WOOD FURRING STRIPS OR OTHER WOOD FRAMING MEMBERS ATTACHED DIRECTLY TO THE INTERIOR OF EXTERIOR MASONRY WALLS OR
CONCRETE WALLS BELOW GRADE EXCEPT WHERE AN APPROVED VAPOR RETARDER IS APPLIED BETWEEN THE WALL AND THE FURRING
STRIPS OR FRAMING MEMBERS.
WASHER & DRYER NOTE:
AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER – PROVIDE POWER , GAS, WATER SUPPLY & DRAINAGE AS REQUIRED - THE CLOTHES
DRYERS VENT SHALL BE OF A RIGID METALLIC MATERIAL AND HAVE A BACKDRAFT DAMPER (CMC 504.4) AND SHALL NOT EXCEED 14-FEET
IN OVERALL LENGTH WITH MAX. OF TWO (2) 90-DEGREE ELBOW, SUBTRACT 2-FEET FOR EACH ADDITIONAL 90-DEGREE ELBOW. (CMC
504.4.2.1) DRYER VENT TERMINATION MUST BE 3-FEET FROM OPENINGS INTO THE BUILDING (DOORS AND OPERABLE WINDOWS), 10-FEET
FROM FORCED AIR INLET, AND 3-FEET FROM PROPERTY LINE (NOT TO DISCHARGE ONTO A PUBLIC WALKWAY). (CMC 502.2.1) IF DRYER
LOCATED IN A CLOSET PROVIDE A MIN. 100 SQ.IN. OPENING IN THE CLOSET DOOR. (CMC. 504.4.1)
*HERS VERIFICATION REQUIRED- REFERENCE T-24.1
NEWPORT BEACH NOTES
1. THE MAXIMUM TIME TO COMPLETE CONSTRUCTION ON A PROJECT IS LIMITED TO THREE YEARS FROM THE DATE OF THE PERMIT FOR
ALL PERMITS ISSUED AFTER AUGUST 21,2019 AS REQUIRED BY NBMC SECTION 15.02.05.
2. G.C. TO PROVIDE A PROJECT INFORMATION SIGN FOR PROJECTS REQUIRING FENCING (NEW STRUCTURE OR ADDITION AND REMODEL TO
AN EXISTING STRUCTURE WITH A COMBINED FLOOR AREA EXCEEDING SEVENTY-FIVE (75) PERCENT OF THE FLOOR AREA OF THE PROPOSED
STRUCTURE) IN DESIGNATED “HIGH DENSITY AREAS”. PROJECT SIGN SHALL COMPLY WITH NBMC SECTION 15.60.030.
BRANDON ARCHITECTS
DATE
T-1.2
PROJECT CONTACT
JEFF VAN VOORHIS, AIA
PROJECT NAME
PROJECT ADDRESS
908 W. OCEANFRONT
NEWPORT BEACH, CA 92661
OWNER INFORMATION
908 NB PROPERTY MANAGEMENT LLC
3717 EUCLID AVE.
DALLAS, TX
PROJECT STATUS
SECOND CHECK
PLAN CHECK NO.
TBD
REVISIONS
NO.
DATE
5/28/2021 HARVEY RESIDENCESUPPLEMENTAL
DOCUMENTS &
NOTES
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
REVISIONS
These documents are the property of BRANDON
ARCHITECTS INC., and are not to be duplicated,
altered or utilized in any ay by any other party
without the expressed authorization of
BRANDON ARCHITECTS. Any unauthorized
duplication or alteration of these documents by
any party is a violation of BRANDON
ARCHITECTS expressed common law copyright
and other property rights thereto, and is subject
to full civil liabilities and penalties. These plans
are also not to be assigned to any third party
without obtaining written authorization and
expressed permission by BRANDON
ARCHITECTS, who shall then be held harmless
and absolved of any liability regarding any use
of these documents by such third party whether
depicted or implied hereon.1 CAL GREEN - RESIDENTIAL MINIMUM REQUIREMENTS
2 RESIDENTIAL CONSTRUCTION MINIMUM REQUIREMENTS
2019 CorrList\RESIDENTIALConstructionMinimumReq 11/2020 1
CITY OF NEWPORT BEACH
COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION 100 Civic Center Drive | P.O. Box 1768 | Newport Beach, CA 92658-8915 www.newportbeachca.gov | (949) 644-3200 RESIDENTIAL
CONSTRUCTION MINIMUM REQUIREMENTS
Applicable Standards: 2019 California Residential Code (CRC); 2019 California Building Code (CBC); 2019 California Plumbing Code (CPC); 2019 California Electrical Code (CEC); 2019 California Mechanical Code (CMC); 2019 Building Energy Efficiency Standards (BEES); 2019 California Green Building Standards Code (Cal Green); & Chapter 15 of the Newport Beach Municipal Code (NBMC)
GENERAL:
1. Residential building undergoing permitted alterations, additions or improvements shall replace non-compliant plumbing fixtures with water-conserving plumbing fixtures meeting the requirements of 2019 California Green Building Standards Code, Section 4.303.1 Plumbing fixture replacement is required prior to issuance of a certificate of occupancy or final inspection by the Chief Building Official. (Civil Code, Section 1101.1 et seq., NBMC 15.11.010)
2. Issuance of a building permit by the City of Newport Beach does not relieve applicants of the legal requirements to observe covenants, conditions and restrictions, which may be recorded against the property or to obtain plans. You should contact your community associations prior to commencement of any construction authorized by this permit.
3. Prior to performing any work in the City right-of-way an encroachment permit must be
obtained from the Public Works Department.
4. A site survey by a licensed surveyor shall be required prior to foundation concrete pour.
5. Garage ceiling height. The minimum unobstructed vertical clearance for parking spaces shall be seven feet, except that the front four feet may have a minimum vertical clearance of four feet. (NBMC 20.40.090 A 4)
6. Utilize one of the city’s approved franchise hauler to recycle and/or salvage a minimum of 65% of the nonhazardous construction and demolition waste. (Cal Green 4.408.1, 4.408.3)
7. Stairways shall not be less than 36 inches clear width. (CRC 311.7.1) The minimum head clearance shall be 6”-8” measured vertically from the sloped line adjoining tread nosing. (CRC 311.7.2)
8. Advisory Note: Homeowners Association (HOA) approval is independent of the City process and may be required for this improvement. Please check with the HOA Board.
9. Additional permits are required for detached structures including but not limited to:
a. Accessory structures, detached patio covers, and trellises, b. Masonry or concrete fences over 3.5 ft. high or within 3 feet of the property line, c. Retaining walls over 4 ft. high from the bottom of the foundation to the top of the wall and any retaining wall within 3 ft. of property line regardless of height.
2019 CorrList\RESIDENTIALConstructionMinimumReq 11/2020 2
d. Electrical and Plumbing for exterior improvements detached from the house (i.e. barbeque, fountain, fire feature)
CONSTRUCTION:
10. Pedestrian protection adjacent to public way to be as follows:
CBC TABLE 3306.1 PROTECTION OF PEDESTRIANS
HEIGHT OF CONSTRUCTION DISTANCE FROM CONSTRUCTION TO LOT LINE TYPE OF PROTECTION REQUIRED
8 feet or less Less than 5 feet Construction railings
5 feet or more None
More than 8 feet
Less than 5 feet Barrier and covered walkway
5 feet or more, but not more than one-fourth the height of construction Barrier and covered walkway
5 feet or more, but between one-fourth and one-half the height of construction Barrier
5 feet or more, but exceeding one-half the height of construction None
11. All exterior lath and plaster shall have two layers of Grade D paper over wood base sheathing. (CRC R703.7.3, CBC 2510.6)
12. Wall covering of showers or tubs with showers shall be of cement plaster, tile, or approved equal, to a height of not less than 72 inches above drain inlet. Backing for tile shall be cement board or cement plaster. (CRC R307.2, CBC 1209.2.3)
13. Safety glazing shall be provided at the following hazardous locations: (CRC R308.4, CBC
2406.4)
a. Swinging, bi-fold, and sliding doors.
b. When located within 60 inches above the floor of wet surfaces such as tubs, showers, saunas, steam rooms, or outdoor swimming pool.
c. Glazing adjacent to doors:
i. Within a 24-inch arc of either vertical edge of doors and within 60 inches of walking surface.
ii. Where the glazing is on a wall perpendicular to the plane of the door in a closed position and within 24 inches of the hinge side of an in-swinging door.
d. Where glazing area is more than 9 sq. ft. in area, with the bottom edge less than 18 inches above the floor, top edge more than 36 inches above floor, and within 36 inches of a walking surface, measured horizontally.
e. Glazing where the bottom exposed edge of the glazing is less than 36 inches above the plane of the adjacent walking surface of stairways, landings between flights of stairs and ramps.
f. Glazing adjacent to the landing at the bottom of a stairway where the glazing is less than 36 inches above the landing and within 60 inches horizontally of the bottom tread.
g. Glazing in guards and railings.
14. All doors from the house into the pool area shall be equipped with an approved alarm or
an approved alternate drowning prevention safety feature. (CBC 3109 (115922))
15. Smoke alarms shall be installed in the following locations (CRC R314.3, CBC 907.2.11.2, 907.2.11.3 & 907.2.11.4):
2019 CorrList\RESIDENTIALConstructionMinimumReq 11/2020 3
a. In each sleeping room.
b. Outside each separate sleeping area in the immediate vicinity of the bedrooms.
c. On each additional story, including basements and habitable attics.
d. Not less than 3 feet horizontally from the door or opening of a bathroom that contains a bathtub or shower.
e. A minimum of 20 feet horizontally from any permanently installed cooking appliance.
f. Smoke alarms shall be hardwired with battery back-up and interconnected unless exempted in accordance with CRC R314.4 & R314.5 or CBC 907.2.10.5 & 907.2.10.6.
16. Carbon monoxide alarms shall be installed in the following locations (CRC R315.3):
a. Outside of each sleeping area in the immediate vicinity of the bedroom(s).
b. On every occupiable level of the dwelling unit including basements.
c. Where a fuel-burning appliance is located within a bedroom or its attached bathroom, a carbon monoxide alarm shall be installed within the bedroom.
Carbon monoxide alarms shall be hardwired with battery back-up and interconnected unless exempted in accordance with CRC R315.6(4).
17. All fenestrations on windows and doors shall have U-factors (0.30 max) and Solar Heat Gain Coefficient (SHGC=0.23 max) values in accordance with T-24 energy calculations. All fenestrations must have temporary and permanent labels.
TEMPORARY GENERATOR:
18. Hand operated construction tools powered by electricity must use power provided by Southern California Edison through a temporary pole or available outlet. In the rare case where electricity is not readily available and a portable temporary generator is necessary, then the following restrictions must be adhered to:
a. Must be portable and may be easily relocated.
b. Temporary generators are to be located a minimum distance from any property
line according to the following table:
Time in Use Hours
Required Setback from Property Line
Required Setback from Adjacent Structures 0 – 1 day 10 feet 5 feet
> 1 day 20 feet 5 feet c. If the minimum distance cannot be achieved, then the generator shall be located the most extreme distance practical to inhibit noise. Other methods to inhibit noise may be utilized when practical.
d. May be operational for a maximum of five consecutive calendar days. After five consecutive calendar days of use, power shall be provided through the use of a temporary power pole.
e. Usage is limited to weekdays between the hours from 8:00 AM and 3:30 PM Monday through Friday. No use on the weekends or federal holidays.
2019 CorrList\RESIDENTIALConstructionMinimumReq 11/2020 4
FIREPLACE:
19. All fireplaces:
a. Factory-built fireplaces, chimneys and all of their components shall be listed and installed in accordance with their listing and manufacturer's installation instructions. (CRC R1004.1)
b. Factory built wood burning fireplaces shall be qualified at the U.S. EPA’s Voluntary Fireplace Program Phase 2 emissions level. (CRC 1004.1.1)
c. Decorative shrouds shall not be installed at the termination of factory-built chimneys except where such shrouds are listed and labeled for use with the specific factory-built chimney system and are installed in accordance with manufacturer's installation instructions. (CRC R1005.2 & CMC 802.5.1.1 & CMC 802.5.4.3)
d. Horizontal openings are not allowed, for exhaust vents, in walls closer than 3 feet to a property line. (Tables R302.1(1)&(2)). Horizontal vent caps shall be 2 feet clear from property lines.
e. Exhaust openings shall not be directed onto walkways. (R303.5.2)
20. Solid fuel burning fireplaces:
a. Provide a permanently anchored gaseous fuel burning pan to the firebox of a solid fuel burning fireplace.
b. Solid fuel burning fireplace must comply with the California Energy Standards mandatory measures.
c. Chimney shall extend at least 2 ft. higher than any portion of the building within 10 ft., but shall not be less than 3 ft. above the highest point where the chimney passes through the roof. (CRC R1003.9)
d. Liquid fueled fireplaces are not allowed for interior use.
21. Direct vent gas appliance fireplace:
a. Direct vent sealed-combustion gas appliance fireplace must comply with the Cal Green code requirements and must comply with ANSI Z21.50. (Cal Green 4.503.1)
MECHANICAL:
22. Rooms containing bathtubs, showers, spas and similar fixtures shall be provided with an exhaust fan with humidity control sensor having a minimum capacity of 50 CFM ducted to terminate outside the building. (CRC R303.3, Cal Green 4.506.1, CBC 1202.5.2.1, CMC 402.5)
23. Where water closet compartment is independent of the bathroom or shower area, a fan will be required in each area. Bathrooms shall have an exhaust fan with humidity control sensor, min. 50 CFM capacity. (CRC R303.3)
24. Where whole house fans are used in bathroom areas, the fan must run continuously and shall not be tied to a humidity control sensor. (Cal Green 4.506.1(2))
25. The clothes dryer vent shall not exceed 14 ft. in overall length with maximum two 90
degree elbows. (CMC 504.4.2.1)
26. Environmental air ducts shall terminate min. 3 feet from property line or openings into building, and 10 feet from a forced air inlet. (CMC 502.2.1)
27. Mechanical equipment shall be installed per the manufacture’s installation instructions. (CMC 303.1)
2019 CorrList\RESIDENTIALConstructionMinimumReq 11/2020 5
28. Domestic range vents to be smooth metallic interior surface. (CMC 504.3)
29. Supply and return air ducts to be insulated at a minimum of R-6. (Cal Energy Code Table 150.1-A.)
PLUMBING:
30. Separate water meters are required for all new duplexes. Separate fire risers are required at each water meter.
31. Plumbing Fixtures:
a. New Construction & Addition/Alterations that increases condition space area, volume, or size (Cal Green 4.303.1):
i. Comply with CAL Green Mandatory Requirements
b. Addition & Alteration: Existing fixtures shall be replaced to meet the following requirements:
i. Shower Heads: 1.8 gpm @ 80 psi
ii. Lavatory Faucets: 1.2 gpm @ 60 psi
iii. Kitchen Faucets: 1.8 gpm @ 60 psi
iv. Water Closet: 1.28 gallons per flush
32. Clearance for water closet to be a minimum of 24 inches in front, and 15 inches from its
center to any side wall or obstruction. (CPC 402.5)
33. The water heater burner to be at least 18 inches above the garage floor, if located in a garage. (CPC 507.13)
34. Install a 3 inch diameter by 3 ft. tall steel pipe embedded in concrete slab for protection of water heaters located in garage. (CPC 507.13.1)
35. Water heaters to be strapped at top and bottom with 1 ½” x 16 gauge strap with 3/8” diameter. X 3” lag bolt each end. (CPC 507.2)
36. ABS and PVC drain waste and vent piping material is limited to 2 stories maximum. (CPC 701.2(2) (a). and 903.1.1)
37. ABS and PVC roof and deck drain material is limited to 2 stories maximum. (CPC 1101.4)
38. Roof and deck drain systems inside the building are required to be installed with directional DWV drainage fittings. (CPC 1101.4 and & 706.0)
39. Cleanouts are required within 2 feet of the connection between the building interior roof/deck drain piping system and the exterior onsite storm drain system. (CPC 1101.13)
40. All hose bibbs shall have vacuum breakers. (CPC 603.5.7)
41. The maximum amount of water closets on a 3 inch horizontal drainage system line is 3. (CPC Table 703.2)
42. The maximum amount of water closets on a 3 inch vertical drainage system line is 4. (CPC Table 703.2)
43. Provide gas line with a min capacity of 200,000 BTU for water heater. (Cal Energy Code 150.0(n))
44. Provide a condensate drain no more than 2 inches above the base of the water heater space. (Cal Energy Code 150.0 (n))
45. Provide a straight vent pipe from the water heater space to the outside termination from the water heater space. (Cal Energy Code 150.0 (n))
2019 CorrList\RESIDENTIALConstructionMinimumReq 11/2020 6
46. Insulate all hot water pipes. (Cal Energy Code 150.0 (j) (2), and CPC 609.11).
47. Isolation valves are required for tankless water heaters on the hot and cold supply lines with hose bibbs on each valve, to flush the heat exchanger. (Cal Energy Code 110.3 (6))
48. Install 1 automatic clothes washer connection per one and two family dwelling. (CPC Table 422.1)
ELECTRICAL:
49. Electrical service shall be underground for new construction, replacement building, or addition to an existing building exceeds fifty (50) percent of the gross floor area of the existing building. (NBMC 15.32.015)
50. Edison Company approval is required for meter location prior to installation.
51. Field inspectors shall review and approve underground service requirement prior to concrete placement.
52. Service equipment and subpanels shall have a min 30” wide by 36” deep clear work space.(CEC 110.26)
53. All lighting is required shall be high efficacy. (California energy code section 150.0 (k) and Table 150.0-A.)
54. Provide a listed 1 inch raceway to accommodate a dedicated 208/240-volt circuit for future electrical vehicle (EV) charger. (Cal Green 4.106.4.1)
55. All receptacle outlets are required shall be listed tamper resistant (CEC 406.12 and 250.52)
56. Combination type AFCI circuit breakers are required for all 120-volt single phase 15/20 amp branch circuits. Except for bathrooms, garages, and outdoors. (CEC 210.12)
57. A minimum of one dedicated 20 amp circuit is required for a bathroom. (CEC 210.11(C)(3))
58. GFCI protection is required for all receptacle outlets located outdoors, garages, accessory buildings, bathrooms, crawl spaces, kitchens, laundry areas, kitchen dishwasher branch circuit, garbage disposal, all areas within 6 feet of a sink, and all receptacles within 6 feet of a bathtub or shower stall. (CEC 210.8)
59. Receptacle outlets are not allowed within or over a bathtub or shower stall. (CEC 406.9 (C))
60. Subpanels are not allow to be located in bathrooms or clothes closets.. Avoid installing sub-panels in fire wall envelope unless the panel is listed or fire protection is clearly detailed to the satisfaction of the building official. (CEC 240.24 (D) and (E)
61. Circuits sharing a grounded conductor (neutral) with two ungrounded (hot) conductors must use a two pole circuit breaker or an identified handle tie. Group non-cable circuits in panel. (CEC 210.4(B)) (CEC 210.4(D))
62. The receptacle outlets that serve kitchen counter tops, dining room, breakfast area, and pantry, must have a min of 2 dedicated 20 amp circuits. (CEC 210.52 (B)(1))
63. Kitchen counter tops 12 inches or wider must have a receptacle outlet. (CEC 210.52(C)(1))
64. Kitchen counter tops must have receptacle outlets so no point along the counter walls is more than 24 inches from a receptacle. (CEC 210.52 (C)(1))
65. Island and peninsular counter tops must have at least one receptacle. (CEC 210.52(C)( 1),(2),and (3))
2019 CorrList\RESIDENTIALConstructionMinimumReq 11/2020 7
66. The spacing for general receptacle outlets must be located so that no point on any wall, fixed glass, or cabinets is over 6 feet from a receptacle outlet. (CEC 210.52(A)(1))
67. Hallways 10 feet or more must have at least one receptacle outlet. (CEC 210.52(H))
68. Garages shall have at least one receptacle for each car space on the interior. The branch circuit supplying the receptacles shall not serve outlets outside of the garage. (CEC 210.52
(G) (1)).
69. Laundry rooms must have at least one dedicated 20 amp receptacle circuit. (CEC 210.11(C) (2)).
70. Provide 120V receptacle within 3 feet of water heater. (Cal Energy Code 150.0 (n) 1 A.)
FOUNDATION:
71. Weep screed for stucco at the foundation plate line shall be a minimum of 4 inches above the earth or 2 inches above paved areas. (CRC R703.7.2.1, CBC 2512.1.2)
72. Fasteners and connectors (nails, anchor bolts, etc.) in contact with preservative-treated wood shall be of hot-dipped zinc-coated galvanized steel, stainless steel, silicon bronze or copper. (CRC R317.3, CBC 2304.10.5.1)
73. Anchor bolts shall include steel plate washers, a minimum of 0.229” x 3” x 3” in size, between sill plate and nut. (CRC R602.11.1, CBC 2308.3, Acceptable alternate SDPWS 4.3.6.4.3)
BRANDON ARCHITECTS
DATE
A-0.0
PROJECT CONTACT
JEFF VAN VOORHIS, AIA
PROJECT NAME
PROJECT ADDRESS
908 W. OCEANFRONT
NEWPORT BEACH, CA 92661
OWNER INFORMATION
908 NB PROPERTY MANAGEMENT
LLC
DEREK & MEGAN HARVEY
3717 EUCLID AVE.
DALLAS, TX
PROJECT STATUS
SECOND CHECK
PLAN CHECK NO.
TBD
REVISIONS
NO.
DATE
04/01/21 HARVEY RESIDENCEARCHITECTURAL
SITE PLAN
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
REVISIONS
These documents are the property of BRANDON
ARCHITECTS INC., and are not to be duplicated,
altered or utilized in any ay by any other party
without the expressed authorization of
BRANDON ARCHITECTS. Any unauthorized
duplication or alteration of these documents by
any party is a violation of BRANDON
ARCHITECTS expressed common law copyright
and other property rights thereto, and is subject
to full civil liabilities and penalties. These plans
are also not to be assigned to any third party
without obtaining written authorization and
expressed permission by BRANDON
ARCHITECTS, who shall then be held harmless
and absolved of any liability regarding any use
of these documents by such third party whether
depicted or implied hereon.
EXISTINGBUILDING
EXISTING
BUILDING
EXISTING
BUILDING
GM
SCO
N18°27'05"E 93.37'N71°37'07"W 40.02'N18°28'51"E 89.07'N77°46'14"W 40.21'(11.09)
FS
(10.74)
FS
(11.26)
FFG
(29.96)
RIDGE (10.94)
FS
(12.07)
FS
(12.15)FS
(11.71)
FS
(11.68)
FS
(39.38)
CHIMNEY TOP
(12.02)
FS(13.13)
TS
(12.22)
FF
(11.47)
FS
(12.26)
FF
(12.14)
FS
(12.28)
FF
(12.21)
TS
(11.29)
FS
(11.10)
FS
(10.92)
FS
(10.14)
FL
(10.14)
FL
(10.19)
FL
(10.20)
FL
(10.23)
FL
(10.23)
FL
(10.82)
FS(10.89)
FS
(11.25)FS
GATE
(10.82)
FS
(11.30)
FS
(11.16)
FS(11.25)
FS
(11.36)
FS
(11.48)
FS(11.51)
FS
(12.10)FS
(33.66)
CHIMNEY TOP
(31.08)
RIDGE
(38.85)
CHIMNEY TOP
(13.03)
TS
(11.60)
FS
(11.62)
FS
(11.59)
FS
(11.62)
FS
(11.64)
FS
(11.18)
NG~SAND
(11.19)
NG~SAND
(10.83)
WM
SCO SCO
GATE
(11.83)
FS
(14.97)TW
(11.88)FS
(14.08)TW
(11.89)FS
(14.13)
TW
(14.03)TW
(11.85)FS
(14.81)TW
(11.85)FS
GATE
(11.25)
FS
(12.11)
FS
(12.06)
FS
(12.85)
FS
(12.78)
FS
(11.85)
FS
(11.79)
FS
(11.66)
FS GP16.49TWS
14.92TW
12.72
TS
12.72
TS11.68FS
11.72FS
11.83
FS
11.94
FS12.52
FS (17.18)TWS
(14.85)TW
LOT 3
TRACT NO. 234
M.M. 13/36-37
LOT 2
LOT 4
OCEANFRONT W.CLW. OCEANFRONTSAND
SAND
SAND
PROPERTY
LINE
PROPERTY
LINE
PROPERTY
LINE
PROPERTY
LINE
FOUND LEAD
HOLE
FOUND TAG IN
EPOXY, LS4653
FOUND LEAD
& TAG, LS4653
(12.01)TS
(11.69)BS
(12.13)TS
(11.80)BS
(12.09)
FS
(12.01)
FS
(12.08)
FS
(12.11)
FS
(12.14)
FS
(12.20)
FS
(12.19)
FS
(12.23)TS
(11.77)BS
C KEYNOTES
A SITE PLAN NOTES
B ANNOTATION LEGEND
DIMENSION NOTE:
ALL DIMENSIONS ARE TO FACE OF SHEATHING (EXT. WALLS) OR FACE OF STRUCTURE (F.O.S.) TYP. U.N.O. ROUNDED TO THE NEAREST
1/8" AND INTERIOR PARTITIONS ARE DIMENSIONED FROM FACE OF STRUCTURE TO FACE OF STRUCTURE (F.O.S.) U.N.O. - CONTACT
ARCHITECT IN WRITING FOR ANY CLARIFICATION OF NOTED DIMENSIONS, DO NOT SCALE PLANS.
GENERAL NOTE:
SEE SHEET A-3.0 FOR ROOF PLAN INFORMATION NOT SHOWN ON THIS SHEET (INCLUDING EAVE DETAILS AND PROJECTION
DISTANCES).
C.N.B. NOTES:
1. ISSUANCE OF A BUILDING PERMIT BY THE CITY OF NEWPORT BEACH DOES NOT RELIEVE APPLICANTS OF THE LEGAL REQUIREMENTSTO OBSERVE COVENANTS, CONDITIONS AND RESTRICTIONS WHICH MAY BE RECORDED AGAINST THE PROPERTY OR TO OBTAIN PLANS
YOU SHOULD CONTACT YOUR COMMUNITY ASSOCIATIONS PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION AUTHORIZED BY THIS
PERMIT.
2. PRIOR TO PERFORMING ANY WORK IN THE CITY RIGHT-OF-WAY AN ENCROACHMENT PERMIT MUST BE OBTAINED FROM THE PUBLIC
WORKS DEPARTMENT.
3. A CAL-OSHA PERMIT IS REQUIRED FOR EXCAVATIONS DEEPER THAN 5' AND FOR SHORING AND UNDERPINNING.
4. ELECTRICAL SERVICE TO BE UNDERGROUND FOR NEW CONSTRUCTION, REPLACEMENT BUILDING OR ADDITIONS TO AN EXISTING
BUILDING EXCEEDING 50% OF THE GROSS FLOOR AREA OF THE EXISTING BUILDING. (NBMC 12.32.015)
5. FIELD INSPECTOR TO REVIEW AND APPROVE UNDERGROUND ELEC. SERVICE REQUIREMENT PRIOR TO CONCRETE PLACEMENT.
6. EDISON COMPANY APPROVAL IS REQUIRED FOR METER LOCATION PRIOR TO INSTALLATION.
LANDSCAPE NOTES:1. ENCROACHMENT PERMIT REQ'D. FOR ANY WORK PROPOSED IN THE PUBLIC R.O.W.
2. IF APPLICABLE, REF. PRELIMINARY LANDSCAPE PLANS, FOR ALL HARDSCAPE & PLANTING AREAS WITH RESPECTIVE HEIGHTS AND
MATERIALS.
POOL:
1. PROVIDE AN ALARM FOR DOORS AND WINDOWS WITH SILL HEIGHTS LESS THAN 60-INCHES ABV.F.F. OF THE DWELLING THAT
FORMS A PART OF THE POOL ENCLOSURE. THE ALARM SHALL BE LISTED AS A WATER HAZARD ENTRANCE ALARM IN ACCORDANCE
WITH UL 2017. THE DEACTIVATION SWITCH SHALL BE AT LEAST 60" ABOVE THE FLOOR IF THE RESIDENCE IS NOT REQUIRED TO BE
ACCESSIBLE. (CBC 3109 & ISPSC 305.4)
2. SUCTION OUTLETS SHALL BE DESIGNED AND INSTALLED WITH SUCTION ANTIENTRAPMENT GRATE IN ACCORDANCE WITH
ANSI/APSP-16 PER CBC 3109 SECTION (B) OF 115928. SUCTION ENTRAPMENT AVOIDANCE FOR POOL AND SPA SHALL BE PROVIDED IN
ACCORDANCE WITH APSP-7 PER ISPSC SECTION 310.
3. PROVIDE POWER SAFETY COVER IN COMPLIANCE WITH ASTM F1346-91 FOR POOL & SPA (CBC 3109 SECTION (3) OF 115922 &
ISPSC 305).
4. POOL ENCLOSURE FENCE SHALL BE 60-INCHES MIN. ABV. FS/NG MEASURED ON THE SIDE THAT FACES AWAY FROM SWIMMING
POOL W/. MAX VERTICAL CLEARANCE OF 2-INCHES BETWEEN FS/NG AND BOTTOM OF THE FENCE/BARRIER MEASURED ON THE SIDE OF
FENCE THAT FACES AWAY FROM SWIMMING POOL. OPENING, GAP, AND VOID IN ENCLOSURE FENCE OR GATE SHALL NOT ALLOW THE
PASSAGE OF 4-INCHES DIAMETER SPHERE OR LARGER. OUTSIDE SURFACE (FACING AWAY FROM SWIMMING POOL) OF THE POOL
ENCLOSURE INCLUDING THE GATE TO BE FREE OF PROTRUSIONS, CAVITIES, OR OTHER PHYSICAL CHARACTERISTICS THAT WOULD
SERVE AS HANDHOLDS OR FOOTHOLDS WHICH COULD ENABLE A CHILD FIVE YEARS OLD OR YOUNGER TO CLIMB OVER. (CBC 3109 &
ISPSC 305)3'-0"S.Y.S.B.3'-0"S.Y.S.B.8'-0"
F.Y.S.B.3'-0"F.O.F.3'-1"F.O.F.3'-10"F.O.F.3'-0"F.O.F.3'-1"F.O.F.3'-0"F.O.F.4'-0"F.O.F.3'-10 7/8"2'-7 1/2"2'-10 5/8"5'-0 1/8"36" MIN.CLR.23'-6 3/4"CLR.30'-9 3/8"CLR.17'-3 3/8"CLR.6'-0"MAX
20'-0"CLR.
11.80' F.F.REF. CIVIL FOR TOP OF SLAB
11.80' F.F.REF. CIVIL FOR TOP OF SLAB15.51' T.W.12.01' F.S.15.51' T.W.12.20' F.S.15.51' T.G.14.01' T.W.12.14' F.S.15.51' T.W.12.11' F.S.15.51' T.W.12.23' F.S.17.25' T.W.11.83' F.S.17.25' T.W.11.25' T.S.15.51' T.G.14.01' T.W.12.11' F.S.SLOPE PER CIVIL
SLOPE PER CIVIL
01.01
01.02
01.04
01.04
01.01
02.01
02.01
01.01
02.37
02.27
02.03
02.31
02.39
32.01
32.01
32.0132.26
32.26
03.12
02.17 02.17
32.18
02.01
32.01
26.02
11.01
32.13
11.33
32.20
32.20
32.20
32.20
02.17
APN: 047 281 15
LOT 3, BLOCK 9
TRM_00234
MM_013_36-38OCEANFRONT W.SAND
W. OCEANFRONTADJACENT PROPERTY
(NOT A PART)
ADJACENT PROPERTY
(NOT A PART)
N18°27'05"E 93.37'
N18°28'51"E 89.07'N77°46'14"W 40.21'N71°37'07"W 40.02'PATIO
(REF. CIVIL & LND. DWGS.)
3-CAR GARAGE
SAND ROOM
ELEV.
PWDR.
GREAT ROOM
DINING
KITCHEN
LOUNGE
PANTRY
UP
ENTRY
STAIRS
PT.2
11.09' FS
PT.4
11.83' FS
PT.1
11.60' FS
PT.3
10.94' FS
PT. 1 11.60'
PT. 2 11.09'
PT. 3 10.94'
PT. 4 11.83'
45.46 / 4 = 11.36'
ROOM NAME
UP
1
15'-6"
N90° 00' 00"E 78.25'
01.13
ROOM TAG
PROPERTY LINE TAG
KEYNOTE TAG
SPOT ELEVATION
RECESSED MAIN SERVICE PANEL - 400 AMP MAX. (MAINTAIN 36" CLEAR FROM
FACE OF PANEL TO ANY OBSTRUCTION) – GC TO COORDINATE W/. UTILITY COMPANY
EXT. STAIRS - MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE ARTIFICIAL LIGHT
SOURCE AT THE TOP LANDING AND FOR STAIR TO THE BASEMENT AT BOTH TOP
AND BOTTOM LANDING (R303.8) - REF. DTL. 3/AD-1 -VERIFY TREADS DEPTH AND
RISERS HT. W/. CIVIL AND LANDSCAPE DWGS
REVISION TAG
BARBEQUE - AS SELECTED TO BE LISTED AND APPROVED, VERIFY W/. OWNER –
PROVIDE POWER AND GAS AS REQUIRED – INSTALL AND MAINTAIN CLEARANCES PER
MFGR. AND SECTION 308 OF CFC
FIREPIT - AS SELECTED TO BE LISTED AND APPROVED, VERIFY W/. OWNER – PROVIDE
POWER AND GAS AS REQUIRED – INSTALL AND MAINTAIN CLEARANCES PER MFGR. AND
SECTION 308 OF CFC
A/C CONDENSER / HEAT PUMP - TO BE IN COMPLIANCE OF SECTION 307.3 OF CPCAS SELECTED, VERIFY W/. OWNER - SIZE TBD, SEE T-24 ENERGY REPORT FOR MORE
INFO – PROVIDE POWER AND SOUND DAMPENING PAD AS REQ’D. – INSTALL AND
MAINTAIN REQUIRED CLEARANCES PER MFGR. INSTRUCTION
TRASH CANS - SCREEN FROM STREET AND PROVIDE MIN. CLEARANCES AS REQ'D.
VERTICAL STORM DRAIN PIPE IN-WALL ( ) / OVERFLOW ( )- MTL. PIPE PER
CHAPTER 11 OF CPC, SIZE PER TABLE 1103.1 (MIN. 2” DIA. PIPE & TYP. 3” DIA. PIPE) – SEE
CIVIL DWGS. FOR TERMINATION DTLS. ABV. OR BLW. GROUND. VERIFY ALL TERMINATIONPOINTS, TYPE AND DETAILS W/. CIVIL PRIOR TO POURING THE CONCRETE SLAB
PROJECT NORTHTRUE NORTHN N
01.01 PROPERTY LINE
01.02 FRONT YARD SETBACK
01.04 SIDE YARD SETBACK
02.01 FOOTPRINT OF EXISTING STRUCTURE
TO BE REMOVED
02.03 CENTERLINE/FLOWLINE OF ALLEY
02.17 (E.) PROPERTY LINE WALL
PROTECT IN PLACE
02.27 (E.) GAS METER LOCATION
REF. SURVEY & CIVIL DWGS.
02.31 (E.) SEWER C.O. LOCATION
REF. SURVEY & CIVIL DWGS.
02.37 (E.) WATER METER LOCATIONREF. SURVEY & CIVIL DWGS.
02.39 (E.) GUARD POST
TO BE REMOVED - REF. SURVEY & CIVIL DWGS.
03.12 DEPRESS SLAB
FOR PEDESTAL FLOOR SYSTEM. REF. CIVIL AND SLAB EDGE PLAN
11.01 FIREPIT
PROVIDE GAS STUB-OUT, REF. LAND. DWGS., G.C. TO VERIFY LOC'N W/. OWNER
11.33 (N.) BBQ.
PROVIDE GAS STUB-OUT AND ELECTRICITY AS REQ'D., REF. LAND. DWGS., G.C. TO VERIFY LOC'N W/. OWNER
26.02 RECESSED MAIN SERVICE PANEL
400 AMP MAX. (MAINTAIN 36" CLEAR FROM FACE OF PANEL TO ANY OBSTRUCTION)
32.01 (N.) HARDSCAPE
COLORED & SCORED CONCRETE OR STONE PAVERS (AS SELECTED), REF. LAND. DWGS.
32.13 (N.) 42" TALL GATE
REF. LANDS. DWGS.
32.18 (N.) LANDSCAPE WALL
CMU PILASTER W/. STUCCO FINISH WITH 18" GLASS TOP, MAX. HT. 42" (REF. CIVIL DWGS.)32.20 (N.) PROPERTY LINE WALL
(MAX. 3' ABV. N.G.) REF. LANDS. DWGS.
32.26 (N.) CONCRETE STEPS ON GRADE
REF. CIVIL DWGS.
SCALE: 3/16" = 1'-0"1ARCHITECTURAL SITE PLAN
SCALE: 1/8" = 1'-0"2GRADE PLANE EXHIBIT
BRANDON ARCHITECTS
DATE
A-0.2
PROJECT CONTACT
JEFF VAN VOORHIS, AIA
PROJECT NAME
PROJECT ADDRESS
908 W. OCEANFRONT
NEWPORT BEACH, CA 92661
OWNER INFORMATION
908 NB PROPERTY MANAGEMENT
LLC
DEREK & MEGAN HARVEY
3717 EUCLID AVE.
DALLAS, TX
PROJECT STATUS
SECOND CHECK
PLAN CHECK NO.
TBD
REVISIONS
NO.
DATE
04/01/21 HARVEY RESIDENCEAREA PLANS
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
REVISIONS
These documents are the property of BRANDON
ARCHITECTS INC., and are not to be duplicated,
altered or utilized in any ay by any other party
without the expressed authorization of
BRANDON ARCHITECTS. Any unauthorized
duplication or alteration of these documents by
any party is a violation of BRANDON
ARCHITECTS expressed common law copyright
and other property rights thereto, and is subject
to full civil liabilities and penalties. These plans
are also not to be assigned to any third party
without obtaining written authorization and
expressed permission by BRANDON
ARCHITECTS, who shall then be held harmless
and absolved of any liability regarding any use
of these documents by such third party whether
depicted or implied hereon.A GENERAL NOTES
C KEYNOTES
B GENERAL NOTES
NOTE:
GENERAL CONTRACTOR TO PROVIDE SHOP DRAWINGS CONSISTENT WITH THE CONSTRUCTION DOCUMENTS. GENERAL
CONTRACTOR TO REVIEW AND APPROVE ALL FINAL SHOP DRAWINGS PRIOR TO FABRICATION & POURING.
ARCHITECT & STRUCTURAL ENGINEER TO REVIEW SHOP DWGS. FOR DESIGN CONFORMITY TO THE CONSTRUCTION DOCUMENTS
PRIOR TO FABRICATION & POURING.
DIMENSION NOTE:
ALL DIMENSIONS ARE TO FACE OF SHEATHING (EXT. WALLS) OR FACE OF STRUCTURE (F.O.S.) TYP. U.N.O. ROUNDED TO THE
NEAREST 1/8" - CONTACT ARCHITECT IN WRITING FOR ANY CLARIFICATION OF NOTED DIMENSIONS, DO NOT SCALE PLANS.
WATERPROOFING AND DAMPPROOFING NOTES:
R406.1 CONCRETE AND MASONRY FOUNDATION DAMPPROOFING
EXCEPT WHERE REQUIRED BY SECTION R406.2 TO BE WATERPROOFED, FOUNDATION WALLS THAT RETAIN EARTH AND ENCLOSE
INTERIOR SPACES AND FLOORS BELOW GRADE SHALL BE DAMPPROOFED FROM THE HIGHER OF (A) THE TOP OF THE FOOTING
OR (B) 6 INCHES (152 MM) BELOW THE TOP OF THE BASEMENT FLOOR, TO THE FINISHED GRADE. MASONRY WALLS SHALL HAVE
NOT LESS THAN 3/8-INCH (9.5 MM) PORTLAND CEMENT PARGING APPLIED TO THE EXTERIOR OF THE WALL. THE PARGING SHALL
BE DAMPPROOFED IN ACCORDANCE WITH ONE OF THE FOLLOWING:
1. BITUMINOUS COATING.
2. THREE POUNDS PER SQUARE YARD (1.63 KG/M2) OF ACRYLIC MODIFIED CEMENT.
3. ONE-EIGHTH-INCH (3.2 MM) COAT OF SURFACE-BONDING CEMENT COMPLYING WITH ASTM C887.
4. ANY MATERIAL PERMITTED FOR WATERPROOFING IN SECTION R406.2.
5. OTHER APPROVED METHODS OR MATERIALS.
EXCEPTION: PARGING OF UNIT MASONRY WALLS IS NOT REQUIRED WHERE A MATERIAL IS APPROVED FOR DIRECT
APPLICATION TO THE MASONRY.CONCRETE WALLS SHALL BE DAMPPROOFED BY APPLYING ANY ONE OF THE LISTED
DAMPPROOFING MATERIALS OR ANY ONE OF THE WATERPROOFING MATERIALS LISTED IN SECTION R406.2 TO THE EXTERIOR OF
THE WALL.
R406.2 CONCRETE AND MASONRY FOUNDATION WATERPROOFING
IN AREAS WHERE A HIGH WATER TABLE OR OTHER SEVERE SOIL-WATER CONDITIONS ARE KNOWN TO EXIST, EXTERIOR
FOUNDATION WALLS THAT RETAIN EARTH AND ENCLOSE INTERIOR SPACES AND FLOORS BELOW GRADE SHALL BE
WATERPROOFED FROM THE HIGHER OF (A) THE TOP OF THE FOOTING OR (B) 6 INCHES (152 MM) BELOW THE TOP OF THE
BASEMENT FLOOR, TO THE FINISHED GRADE. WALLS SHALL BE WATERPROOFED IN ACCORDANCE WITH ONE OF THE FOLLOWING:
1. TWO-PLY HOT-MOPPED FELTS.
2. FIFTY-FIVE-POUND (25 KG) ROLL ROOFING.
3. SIX-MIL (0.15 MM) POLYVINYL CHLORIDE.
4. SIX-MIL (0.15 MM) POLYETHYLENE.
5. FORTY-MIL (1 MM) POLYMER-MODIFIED ASPHALT.
6. SIXTY-MIL (1.5 MM) FLEXIBLE POLYMER CEMENT.
7. ONE-EIGHTH-INCH (3 MM) CEMENT-BASED, FIBER-REINFORCED, WATERPROOF COATING.
8. SIXTY-MIL (1.5 MM) SOLVENT-FREE LIQUID-APPLIED SYNTHETIC RUBBER.
ALL JOINTS IN MEMBRANE WATERPROOFING SHALL BE LAPPED AND SEALED WITH AN ADHESIVE COMPATIBLE WITH THE
MEMBRANE.
EXCEPTION: ORGANIC-SOLVENT-BASED PRODUCTS SUCH AS HYDROCARBONS, CHLORINATED HYDROCARBONS, KETONES AND
ESTERS SHALL NOT BE USED FOR ICF WALLS WITH EXPANDED POLYSTYRENE FORM MATERIAL. USE OF PLASTIC ROOFING
CEMENTS, ACRYLIC COATINGS, LATEX COATINGS, MORTARS AND PARGINGS TO SEAL ICF WALLS IS PERMITTED. COLD-SETTING
ASPHALT OR HOT ASPHALT SHALL CONFORM TO TYPE C OF ASTM D449. HOT ASPHALT SHALL BE APPLIED AT A TEMPERATURE
OF LESS THAN 200°F (93°C).
SLAB ON GRADE NOTE:
PROVIDE BASE PER R506.2.2 AND VAPOR RETARDER PER R506.2.3 W/. CAPILLARY BREAK
UP
1'-2 1/2"34'-9 1/2"15'-11 1/8"23'-8 3/4"
1'-2 1/2"34'-9 1/2"15'-11"23'-8 7/8"12'-11 1/2"33'-8 5/8"1'-8 3/8"5'-10 3/4"5'-1 1/4"
4'-10 5/8"33'-7 5/8"21'-0 1/4"7'-2 5/8"5'-5"13'-5"18'-10"6'-9"10"
1'-5 5/8"
6'-1"
E
J1
J 2
OA5
OA6
OA7
OPEN AREA 4
59 sq ft
OPEN AREA 3
91 sq ft
DN.
7'-4 3/8"8'-2 7/8"2'-0"I
G
F H
F1
F2
SECOND FLOOR
A: 2,378 sq ft
8'-6 7/8"
3'-1 1/2"4'-10 1/2"1'-2 5/8"34'-9 3/8"7'-4 1/8"9'-0 7/8"3'-6 3/4"20'-7 1/4"32'-9 5/8"11"7'-2 5/8"5'-3"26'-6"2'-0 5/8"6'-1 1/8"
OA1OA3
Buildable Area
2,815 sq ft
OPEN AREA 1
A: 60 sq ft
OPEN AREA 2
A: 216 sq ft
UP
25'-6 1/4"32'-9 5/8"8'-2 7/8"33'-7 5/8"14'-11"17'-10 5/8"A
B
D
C
G1
G2
-G3
OA2
OA4 A1
A2
FIRST FLOOR
A: 1,717 sq ft 3-CAR GARAGE
A: 732 sq ft
DN.
26'-5 3/4"19'-1 1/4"7'-7 3/8"9'-11 3/8"
5'-1 1/4"6'-4 5/8"12'-6 1/2"15'-0"10'-4 5/8"12'-9 1/8"
K
M
L1
L2
THIRD FLOOR
A: 422 sq ft
VIEW DECK SF
A: 1,023 sq ft
CABANA
A: 132 sq ft
A 35' - 3 5/8" X 33' - 7 5/8" 1169.88
A1 0' - 8 3/8" X 2' - 0 5/8" 2.5
A2 0' - 8 3/8" X 5' - 3" 6.4
B 7' - 4 1/8" X 27' - 0 1/4" 187.42
C 9' - 0 7/8" X 32' - 9 5/8" 297.61
D 3' - 6 3/4" X 14' - 11" 53.14
TOTAL 1716.95
G1 3' - 6 3/4" X 17' - 10 5/8" 63.72
G2 20' - 7 1/4" X 32' - 9 5/8" 675.86
-G3 8' - 6 7/8" X 0' - 11" -7.86
TOTAL 731.72
OA1 7' - 3 1/8" X 6' - 9 3/8" 59.48
OA2 4' - 1 3/8" X 26' - 6" 161.48
OA3 3' - 8 5/8" X 33' - 7 5/8" 44.61
OA4 4' - 10 1/2" X 2' - 0 5/8" 10
TOTAL 275.57
E 6' - 1 7/8" X 12' - 11 1/2" 95.43
F 35' - 3 1/2" X 33' - 7 5/8" 1170.23
F1 0' - 8 1/2" X 2' - 0" 2.42
F2 0' - 8 1/2" X 5' - 5" 6.55
G 15' - 11 1/8" X 21' - 0 1/4" 334.8
H 23' - 8 3/4" X 33' - 8 5/8" 800.47
I 0' - 9 1/2" X 6' - 8" 5.63
J1 5' - 1 1/4" X 5' - 10 3/4" -30.09
J2 4' - 10 5/8" X 1' - 8 3/8" -8.3
TOTAL 2377.14
SECOND FLOOR LIVING
GARAGE
FIRST FLOOR LIVING
FIRST FLOOR OPEN AREA
A 35' - 3 5/8" X 33' - 7 5/8" 1169.88
A1 0' - 8 3/8" X 2' - 0 5/8" 2.5
A2 0' - 8 3/8" X 5' - 3" 6.4
B 7' - 4 1/8" X 27' - 0 1/4" 187.42
C 9' - 0 7/8" X 32' - 9 5/8" 297.61
D 3' - 6 3/4" X 14' - 11" 53.14
TOTAL 1716.95
G1 3' - 6 3/4" X 17' - 10 5/8" 63.72
G2 20' - 7 1/4" X 32' - 9 5/8" 675.86
-G3 8' - 6 7/8" X 0' - 11" -7.86
TOTAL 731.72
OA1 7' - 3 1/8" X 6' - 9 3/8" 59.48
OA2 4' - 1 3/8" X 26' - 6" 161.48
OA3 3' - 8 5/8" X 33' - 7 5/8" 44.61
OA4 4' - 10 1/2" X 2' - 0 5/8" 10
TOTAL 275.57
E 6' - 1 7/8" X 12' - 11 1/2" 95.43
F 35' - 3 1/2" X 33' - 7 5/8" 1170.23
F1 0' - 8 1/2" X 2' - 0" 2.42
F2 0' - 8 1/2" X 5' - 5" 6.55
G 15' - 11 1/8" X 21' - 0 1/4" 334.8
H 23' - 8 3/4" X 33' - 8 5/8" 800.47
I 0' - 9 1/2" X 6' - 8" 5.63
J1 5' - 1 1/4" X 5' - 10 3/4" -30.09
J2 4' - 10 5/8" X 1' - 8 3/8" -8.3
TOTAL 2377.14
SECOND FLOOR LIVING
GARAGE
FIRST FLOOR LIVING
FIRST FLOOR OPEN AREA
OA5 7' - 3 1/8" X 6' - 9 3/8" 81.62
OA6 4' - 1 3/8" X 26' - 6" 9.85
OA7 3' - 8 5/8" X 33' - 7 5/8" 59.48
TOTAL 150.95
K 26' - 5 3/4" X 19' - 1 1/4" 505.86
-L1 5' - 1 1/4" X 12' - 6 1/2" -64.01
-L2 6' - 4 5/8" X 15' - 0" -95.78
M 9' - 11 3/8" X 7' - 7 3/8" 75.75
TOTAL 421.82
THIRD FLOOR LIVING
SECOND FLOOR OPEN AREA
BUILDING AREA
LIVING
GARAGE
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
3-CAR GARAGE
1,717
2,377
422
4,516 sq ft
732
732 sq ft
5,248 sq ft
OA5 7' - 3 1/8" X 6' - 9 3/8" 81.62
OA6 4' - 1 3/8" X 26' - 6" 9.85
OA7 3' - 8 5/8" X 33' - 7 5/8" 59.48
TOTAL 150.95
K 26' - 5 3/4" X 19' - 1 1/4" 505.86
-L1 5' - 1 1/4" X 12' - 6 1/2" -64.01
-L2 6' - 4 5/8" X 15' - 0" -95.78
M 9' - 11 3/8" X 7' - 7 3/8" 75.75
TOTAL 421.82
THIRD FLOOR LIVING
SECOND FLOOR OPEN AREA
SCALE: 3/16" = 1'-0"2SECOND LEVEL AREA PLAN
SCALE: 3/16" = 1'-0"1FIRST LEVEL AREA PLAN
SCALE: 3/16" = 1'-0"3THIRD LEVEL AREA PLAN
BRANDON ARCHITECTS
DATE
A-1.0
PROJECT CONTACT
JEFF VAN VOORHIS, AIA
PROJECT NAME
PROJECT ADDRESS
908 W. OCEANFRONT
NEWPORT BEACH, CA 92661
OWNER INFORMATION
908 NB PROPERTY MANAGEMENT LLC
3717 EUCLID AVE.
DALLAS, TX
PROJECT STATUS
SECOND CHECK
PLAN CHECK NO.
TBD
REVISIONS
NO.
DATE
5/28/2021 HARVEY RESIDENCE3D VIEWS
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
REVISIONS
These documents are the property of BRANDON
ARCHITECTS INC., and are not to be duplicated,
altered or utilized in any ay by any other party
without the expressed authorization of
BRANDON ARCHITECTS. Any unauthorized
duplication or alteration of these documents by
any party is a violation of BRANDON
ARCHITECTS expressed common law copyright
and other property rights thereto, and is subject
to full civil liabilities and penalties. These plans
are also not to be assigned to any third party
without obtaining written authorization and
expressed permission by BRANDON
ARCHITECTS, who shall then be held harmless
and absolved of any liability regarding any use
of these documents by such third party whether
depicted or implied hereon.
SCALE: 1/8" = 1'-0"1NORTHEAST AXONOMETRIC
SCALE: 1/8" = 1'-0"2SOUTHEAST AXONOMETRIC
SCALE: 1/8" = 1'-0"4NORTHWEST AXONOMETRIC
SCALE: 1/8" = 1'-0"3SOUTHWEST AXONOMETRIC
BRANDON ARCHITECTS
DATE
A-2.0
PROJECT CONTACT
JEFF VAN VOORHIS, AIA
PROJECT NAME
PROJECT ADDRESS
908 W. OCEANFRONT
NEWPORT BEACH, CA 92661
OWNER INFORMATION
908 NB PROPERTY MANAGEMENT LLC
3717 EUCLID AVE.
DALLAS, TX
PROJECT STATUS
SECOND CHECK
PLAN CHECK NO.
TBD
REVISIONS
NO.
DATE
5/28/2021 HARVEY RESIDENCEFIRST & SECOND
LEVEL FLOOR PLAN
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
REVISIONS
These documents are the property of BRANDON
ARCHITECTS INC., and are not to be duplicated,
altered or utilized in any ay by any other party
without the expressed authorization of
BRANDON ARCHITECTS. Any unauthorized
duplication or alteration of these documents by
any party is a violation of BRANDON
ARCHITECTS expressed common law copyright
and other property rights thereto, and is subject
to full civil liabilities and penalties. These plans
are also not to be assigned to any third party
without obtaining written authorization and
expressed permission by BRANDON
ARCHITECTS, who shall then be held harmless
and absolved of any liability regarding any use
of these documents by such third party whether
depicted or implied hereon.
01.06 LINE OF ROOF, EAVES & OVERHANGS ABOVE
03.04 DEPRESSED SLAB/STRUCTURE FOR FIREPLACE
COORD. WITH MFG'R. & GENERAL CONTRACTOR, REF. STRUCT. DWGS.
03.06 DEPRESSED SLAB FOR ELEVATOR
12". COORD. WITH ELEVATOR MFG. & G.C., REF. STRUCT. DRAWINGS
03.12 DEPRESS SLAB
FOR PEDESTAL FLOOR SYSTEM. REF. CIVIL AND SLAB EDGE PLAN
06.38 BUILT-IN CLOSET
CUSTOM PER INTERIOR DESIGNER
06.47 TOWEL RACK PER I.D.
CUSTOM RACK AND SHELVES PER I.D.
06.48 DEPRESS STRUCTURE FOR FLUSH SHOWER CONDITION
COORD. WITH I.D. & GENERAL CONTRACTOR, REF. STRUCT. DWGS.
08.02 7 3/4" STEP AT IN SWING DOORS (R311.3.1.)
08.05 WINDOW TO MEET EGRESS REQUIREMENTS
REF. DOOR AND WINDOW NOTES #6, SHT. A-7.008.09 GARAGE DOOR
RATED, 1-3/8" SOLID CORE, SELF-CLOSING AND SELF-LATCHING. REF. DOOR SCHEDULE
09.24 TILE/STONE PAVERS
ON CONCRETE SETTING BED O/ WATERPROOF MEMBRANE REF. MAT. SCHEDULE (CLASS 'A' ASSEMBLY)
10.01 EXTERIOR GLASS GUARDRAIL
TEMPERED & LAMINATED - MIN. 42" HIGH - 4" MAX. SPHERE OPENING, REF. DTL. 4/AD-1
10.04 INTERIOR GLASS GUARDRAIL
MIN. 42" HIGH - MATERIAL AS SELECTED, <4" MAX. SPHERE OPENING, REF. DTL. 4/AD-1
10.05 INTERIOR GUARDRAIL
MIN. 42" HIGH - MATERIAL AS SELECTED, <4" MAX. SPHERE OPENING, REF. DTL. 4/AD-1
10.07 STAIRS
MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS THAN 1 FOOT CANDLE
(CBC 1205.4) REF. DTL. 3/AD-1
10.08 CUSTOM STEEL STRINGER STAIR
4" MAX OPENING BETWEEN TREADS. REF. STRUCT. DTL.- ARCH TO APPRV. SHOP DWGS
10.12 CUSTOM WOOD SCREEN
WOOD SCREEN PER I.D. ARCH TO APPV. SHOP DWGS. PRIOR TO FABRICATION11.05 WINE FRIDGE
VERIFY APPLIANCE W/. OWNER
11.21 FIREPLACE
PREFABRICATED, GAS ONLY, DIRECT VENT 'FLARE - CORNER' (FLARE-RC-45, ANSI Z21.88-CSA 2.33) G.C. TO VERIFY
SELECTION WITH CLIENT [DTL. 22/AD-1] (FACTORY BUILT FIREPLACES, CHIMNEYS, AND ALL OF THEIR COMPONENTS
SHALL BE LISTED AND INSTALLED IN ACCORDANCE W/. THEIR LISTING AND MFG'R. INSTALLATION INSTRUCTIONS.
FIREPLACE MUST COMPLY W/. THE CALIFORNIA ENERGY STANDARDS MANDATORY MEASURES.)
11.22 FIREPLACE
PREFABRICATED, GAS ONLY, DIRECT VENT 'FLARE - FF-45-H' - ANSI Z21.50B-2014. G.C. TO VERIFY SELECTION WITH
CLIENT [DTL. 22/AD-1] (FACTORY BUILT FIREPLACES, CHIMNEYS AND ALL OF THEIR COMPONENTS SHALL BE LISTED AN
INSTALLED IN ACCORDANCE W/. THEIR LISTING AND MFG'R. INSTALLATION INSTRUCTIONS. FIREPLACE MUST COMPLY
W/. THE CALIFORNIA ENERGY STANDARDS MANDATORY MEASURES.)
12.01 FURNISHINGS
AS SELECTED
14.01 RESIDENTIAL ELEVATOR
'CALIFORNIA CUSTOM LIFT, INC.' OR EQUIV., SHAFT SIZE = 56"" X 60"" CLEAR - PROVIDE SHOP DWGS. TO ARCH. PRIOR
TO PURCHASE & INSTALLATION22.04 BATHTUB
FREE-STANDING, AS SELECTED (VERIFY LOC'N. OF FIXTURES W/. OWNER)
22.05 SHOWER
PROVIDE TILE W/. CEMENT BACKING MIN. 72" HIGH (R307.2)
22.12 DECK DRAIN
SLOPE 2% MIN. - REF. DTL. 12/AD-1
22.20 CUSTOM SHOWER SEAT
SEAT PER I.D.
22.22 PROVIDE POT FILLER
VERIFY LOCATION W/. G.C., I.D. & OWNER
23.08 HEATED ELECTRIC FLOORS
PROVIDE WIRING AS REQ'D, G.C. AND CLIENT TO VERIFY AND REVIEW PRODUCT
A ANNOTATION LEGEND
B KEYNOTES
4
8
10
9
7
3
11
REF
W/D.
DW
TR
FRZ 3'-0"S.Y.S.B.3'-0"S.Y.S.B.8'-0"
F.Y.S.B.30'-9 3/8"CLR.17'-3 3/8"CLR.5'-8"7'-10 3/4"20'-0"CLR.
3
A-5.0
3
A-5.0
2
A-5.0
2
A-5.0
1
A-5.1
1
A-5.1
1
A-5.0
1
A-5.0
3
A-5.1
3
A-5.1
2
A-5.1
2
A-5.1
1
A-4.0
2
A-4.0
4
A-4.0
3
A-4.0
11.22
11.05
10.12
03.06
14.01
10.08
22.05
22.20
03.12
03.06
22.22
08.09
08.02
08.02
DIRECT VENT TERMINATION
DRYER VENT TERMINATION
3-CAR GARAGE
SAND ROOM
ELEV.
PWDR.
GREAT ROOM
DINING
KITCHEN
LOUNGE
PANTRY
UP17R x 7 3/8"4
2
3
9
6
21
1
7 6 5
5
23'-6 3/4"CLR.
03.04
10.05
01.06
ENTRY
STAIRS
310
UP 16R x 6 7/8"28
29
26
19
26
27
2018 21
23
24
22
1315
14
15
16
17
25
24
23
18.1
21.1
D
W
3
A-5.0
3
A-5.0
2
A-5.0
2
A-5.0
1
A-5.1
1
A-5.1
1
A-5.0
1
A-5.0
3
A-5.1
3
A-5.1
2
A-5.1
2
A-5.1
1
A-4.0
2
A-4.0
4
A-4.0
3
A-4.03'-0"S.Y.S.B.3'-0"S.Y.S.B.8'-0"
F.Y.S.B.22.30'F.F.
22.30'F.F.
21.87'F.F.
2% MIN.
10.04
06.48
22.05
22.20
06.48
22.05
22.20
06.4822.05
22.20
06.48
22.05
22.20
06.48
22.05
22.20
08.05
08.05
10.01
09.24
06.38
22.04
12.01
10.12
23.08
22.12
01.06
01.06
A1
A2
A3
DIRECT VENT TERMINATION
OPEN TO BLW.
RETREAT/OFFICE STAIRS
ELEV.BED #2
BED #3
BATH #3
W.I.C.
BATH #4
BATH #2
BED #4
LNDRY.
MASTER W.I.C.MASTER BATH
W/C.
MASTER SUITE
BED #5
BATH #5
W.I.C.
MECH.
10.07
DN.17R x 7 3/8"12
1211 13
14
2021
25
18 1719 16
08.05
08.0508.05
11.21
06.47
NOTE: MECHANICAL
SPACES SHALL BE
UNFINISHED
ROOM NAME
UP
19R x 7 5/8"
D
REF / FRZ
W / DW
DW TR
1AD-1.0
1
15'-6"
1
A-4.0
1
A-5.0
01.13
1
ELEVATION/SECTION INDICATOR
ROOM TAG
KEYNOTE TAG
SPOT ELEVATION
1-HR RATED EXT CONDITION - REF. DTLS. 14/AD-1
1-HR RATED INT CONDITION - REF. DTLS. 7/AD-1
FIRE RATED CEILING ASS'Y - REF. DTLS. 7/AD-1
1i WINDOW TAG
DOOR TAG
CASEWORK, BASE CABINET W/. COUNTERTOP - AS SELECTED PER I.D., VERIFY
W/. I.D. & OWNER
CASEWORK, UPPER CABINET/SHELVES - AS SELECTED PER I.D., VERIFY W/. I.D. &
OWNER
REFRIGERATOR (REF) & FREEZER (FRZ) - AS SELECTED PER I.D., VERIFY W/.I.D. & OWNER – PROVIDE POWER AND WATER SUPPLY AS REQUIRED
VANITY SINK - AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER – LAVATORY TO HAVE
24” MIN. CLEAR SPACE IN FRONT OF IT.(CPC 402.5) W/. MAXIMUM FLOW RATE OF 1.2 GPM
@ 60 PSI AND MIN. FLOW RATE OF 0.8 GPM @ 20 PSI PER SECTION 4.303.1 OF CALGREEN
BUILT-IN APPLIANCE, DISHWASHER (DW) & TRASH COMPACTOR (TR) - ASSELECTED PER I.D., VERIFY W/. I.D. & OWNER – PROVIDE POWER , WATER SUPPLY
& DRAINAGE PIPE AS REQUIRED
WASHER (W) & DRYER (D) / STACKED (W/D) - AS SELECTED PER I.D., VERIFY W/. I.D.
& OWNER – PROVIDE POWER , GAS, WATER SUPPLY & DRAINAGE AS REQUIRED - THECLOTHES DRYERS VENT SHALL BE OF A RIGID METALLIC MATERIAL AND HAVE A
BACKDRAFT DAMPER (CMC 504.4) AND SHALL NOT EXCEED 14-FEET IN OVERALL LENGTH
WITH MAX. OF TWO (2) 90-DEGREE ELBOW, SUBTRACT 2-FEET FOR EACH ADDITIONAL 90-
DEGREE ELBOW. SEE WASHER & DRYER NOTES, REF. T-1.1.
TOILET - WATER CLOSET SHALL BE IN COMPLIANCE OF SECTION 411.0 OF CPC AND HAS
MAX EFFECTIVE FLUSH RATE OF 1.28 GAL. PER FLUSH (CPC 411.2). WATER CLOSETS CLR.
TO BE 24” IN FRONT AND 15” FROM ITS CENTER TO ANY SIDE WALL OR OBSTRUCTION.
(CPC 402.5 & CRC R307) – REF. CALGREEN NOTES ON T SHTS. FOR MAX FLOW RATE
STAIRS - MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE AN ILLUMINATION LEVEL OF NOT
LESS THAN 1 FOOT CANDLE AS MEASURED AT THE CENTER OF TREADS AND
LANDING WITH ARTIFICIAL LIGHTING (R303.7) - REF. DTL. 3/AD-1
ELEVATOR - PRIVATE RESIDENCE ELEVATOR IN COMPLIANCE W/. ASME A17.1/CSA B44
AS SELECTED PER PLANS, VERIFY W/. OWNER – PROVIDE POWER AS REQUIRED (CRCR321.1)
EXT. STAIRS - MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE ARTIFICIAL LIGHT SOURCE AT
THE TOP LANDING AND FOR STAIR TO THE BASEMENT AT BOTH TOP AND BOTTOMLANDING (R303.8) - REF. DTL. 3/AD-1 -VERIFY TREADS DEPTH AND RISERS HT. W/. CIVIL
AND LANDSCAPE DWGS
WINDOW - AS SPECIFIED, SEE WINDOW SCHEDULE AND GENERAL NOTES ON SHEET A-
7.0 - SHGC & U-FCTOR PER T-24 ENERGY REPORT – SEE SHEET AD-2.0 FOR JAMB,
HEAD AND SILL DETAILS, PROVIDE FLASHING AND WATERPROOFING AT WINDOW
OPENING PER THE WINDOW MFGR. INSTRUCTION AND/OR FLASHING MFGR.
INSTRUCTION PER SECTIONS R609.1 & R703.4 OF CRC
DOORS - AS SPECIFIED, SEE WINDOW SCHEDULE AND GENERAL NOTES ON SHEET A-7.0
- SHGC & U-FCTOR PER T-24 ENERGY REPORT – SEE SHEET AD-2.0 FOR JAMB, HEADAND THRESHOLD DETAILS, PROVIDE FLASHING AND WATERPROOFING AT DOOR
OPENING PER THE DOOR MFGR. INSTRUCTION AND/OR FLASHING MFGR. INSTRUCTION
PER SECTIONS R609.1 & R703.4 OF CRC
FIREPLACE - FACTORY-BUILT DIRECT VENT GAS FIREPLACE W/. SEALED COMBUSTION
(CALGREEN 4.503) - FACTORY-BUILT FIREPLACES, CHIMNEYS AND ALL OF THEIR
COMPONENTS SHALL BE LISTED AND INSTALLED IN ACCORDANCE WITH THEIR LISTING
AND MANUFACTURER'S INSTALLATION INSTRUCTIONS. (CRC R1004.1)
STRUCTURAL STEEL COLUMN - PER STRUCT., REF. STRUTC. DWGS, - PAINT AND
SEAL AS REQUIRED – ARCH. TO APPV. COLOR FOR EXPOSED STEEL COLUMNS
BUILT-IN CLOSET - AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER
STRUCTURAL WOOD POST/COLUMN - PER STRUCT., REF. STRUTC. DWGS, - PAINT,
STAIN AND SEAL AS REQUIRED – ARCH. TO APPV. PAINT COLOR FOR EXPOSED WOOD
POST/COLUMN, IF TO BE STAINED PROVIDE STAINED SAMPLE FOR ARCH, APPROVAL
RECESSED MAIN SERVICE PANEL - 400 AMP MAX. (MAINTAIN 36" CLEAR FROM
FACE OF PANEL TO ANY OBSTRUCTION) – GC TO COORDINATE W/. UTILITY COMPANY
FAU - PROVIDE GAS S.O., POWER, AND VENTING AS REQ'D. BY MFG'R. – INSTALL PER
MFGR. INSTRUCTION
KITCHEN / BAR SINK - AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER – SINK TO
COMPLY W/. REQUIREMENT OF SECTION 420.0 OF CPC AND HAVE A MAX FLOW RATE OF
1.8 GPM @ 60 PSI PER SECTION 4.303.1 OF CALGREEN – TRAP AND VENT FOR ISLAND
SINK AND SIMILAR EQUIPMENT SHALL BE PER SECTION 909.0 OF CPC
KITCHEN RANGE WITH EXHAUST HOOD - AS SELECTED PER I.D., VERIFY W/. I.D. &
OWNER – PROVIDE POWER AND GAS AS REQUIRED - 30” MIN. VERTICAL CLEARANCE TO
ANY COMBUSTIBLE MATERIAL ABV. COOKING TOP (CMC 920.3.2) –EXHAUST HOOD TO
HAVE EXHAUST RATE OF MIN. 100 CFM AND VENT TO OUTDOOR , HOOD DUCTS TO BE
OF METAL WITH SMOOTH INTERIOR FINISH PER SECTION 504.3 OF CMC
CASEWORK, TALL CABINET - AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER
CALL-OUT TAG
REVISION TAG
ROOF/DECK DRAIN - PER CHAPTER 11 OF CPC - SIZE THE DRAIN AND PIPING PER
TABLE 1103.1 AND 1103.2 OF CPC – ROOF DRAIN SHALL HAVE DOMED STRAINER (CPC
1102.2) – REF. DETAIL 11/AD-1.0
OVERFLOW OR EMERGENCY DRAIN - PER CHAPTER 11 OF CPC - COPPER OR EQ.,
INSTALL PER MFGR. INSTRUC., SLOPED TOWARD IN-WALL DRAIN INLETS – SLOPE AND
SIZE PER TABLE 1103.3 OF CPC – REF. DTL. 11/AD-1.0
CHANNEL DRAIN - CHANNEL DRAIN W/. GRATE IN COMPLIANCE W/. CHAPTER 11 OF
CPC - COPPER OR EQ., INSTALL PER MFGR. INSTRUCTION, SLOPED TOWARD IN-WALL
DRAIN INLETS – SLOPE AND SIZE PER TABLE 1103.3 OF CPC – REF. DETAIL 11/AD-1.0,
ARCH. TO APPV. GRATE COLOR AND TYPE
A/C CONDENSER / HEAT PUMP - TO BE IN COMPLIANCE OF SECTION 307.3 OF CPC
AS SELECTED, VERIFY W/. OWNER - SIZE TBD, SEE T-24 ENERGY REPORT FOR MORE
INFO – PROVIDE POWER AND SOUND DAMPENING PAD AS REQ’D. – INSTALL AND
MAINTAIN REQUIRED CLEARANCES PER MFGR. INSTRUCTION
SCALE: 1/4" = 1'-0"1FIRST LEVEL FLOOR PLAN
SCALE: 1/4" = 1'-0"2SECOND LEVEL FLOOR PLAN
BRANDON ARCHITECTS
DATE
A-2.1
PROJECT CONTACT
JEFF VAN VOORHIS, AIA
PROJECT NAME
PROJECT ADDRESS
908 W. OCEANFRONT
NEWPORT BEACH, CA 92661
OWNER INFORMATION
908 NB PROPERTY MANAGEMENT
LLC
DEREK & MEGAN HARVEY
3717 EUCLID AVE.
DALLAS, TX
PROJECT STATUS
SECOND CHECK
PLAN CHECK NO.
TBD
REVISIONS
NO.
DATE
04/01/21 HARVEY RESIDENCETHIRD LEVEL FLOOR
PLAN
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
REVISIONS
These documents are the property of BRANDON
ARCHITECTS INC., and are not to be duplicated,
altered or utilized in any ay by any other party
without the expressed authorization of
BRANDON ARCHITECTS. Any unauthorized
duplication or alteration of these documents by
any party is a violation of BRANDON
ARCHITECTS expressed common law copyright
and other property rights thereto, and is subject
to full civil liabilities and penalties. These plans
are also not to be assigned to any third party
without obtaining written authorization and
expressed permission by BRANDON
ARCHITECTS, who shall then be held harmless
and absolved of any liability regarding any use
of these documents by such third party whether
depicted or implied hereon.
A ANNOTATION LEGEND
B KEYNOTES
10
DN.16R x 6 7/8"31
32
28
33
34
27
30
30 29
3
A-5.0
3
A-5.0
2
A-5.0
2
A-5.0
1
A-5.1
1
A-5.1
1
A-5.0
1
A-5.0
3
A-5.1
3
A-5.1
2
A-5.1
2
A-5.1
1
A-4.0
2
A-4.0
4
A-4.0
3
A-4.03'-0"S.Y.S.B.3'-0"S.Y.S.B.8'-0"
F.Y.S.B.
5'-0"5'-6"31.47' F.F.
31.84' F.F.
09.31
09.3109.28
09.28
10.01
10.01
10.04
10.07 2% MIN.2% MIN.
2% MIN.1:121:12
1:123:122% MIN.2% MIN.2% MIN.2% MIN.06.48
22.05
22.20
09.31
05.07
22.19
22.19
22.192% MIN.2% MIN.05.07
05.07 05.06
05.06
ATTIC VENT CALC.;
355 S.F. ATTIC SPACE
355/150 = 2.37 = 341.28 S.I.
PROVIDED DORMERS = 130 S.I. X 3 = 390 S.I.
341.28 S.I. > 390 S.I.
09.31
09.24
09.24
OPEN TO BLW.
FUTURE SPA
OPEN TO ABV.
OPEN TO ABV.
OPEN TO ABV.
OPEN TO ABV.
NOTE: MECHANICALSPACES SHALL BE
UNFINISHED, 6'
CEILINGS MAX.
TRAVEL DISTANCE
34' - 6 1/2" + 12' - 5 5/8" + 2' - 1 3/8" =
TOATAL: 49.12 STEPSTEPNOTE: DEPRESS
FRMG.
NOTE: ALL ACCESSORY
STRUCTURES ON ROOF DECK
SHALL COMPLY WITH
MAXIMUM HEIGHT FOR FLAT
ROOFS, REF. ELEVS.
BONUS ROOM ELEV.
MECH.
MECH.
BATH #6
STAIRS
ROOM NAME
UP
19R x 7 5/8"
D
REF / FRZ
W / DW
DW TR
1AD-1.0
1
15'-6"
1
A-4.0
1
A-5.0
01.13
1
ELEVATION/SECTION INDICATOR
ROOM TAG
KEYNOTE TAG
SPOT ELEVATION
1-HR RATED EXT CONDITION - REF. DTLS. 14/AD-1
1-HR RATED INT CONDITION - REF. DTLS. 7/AD-1
FIRE RATED CEILING ASS'Y - REF. DTLS. 7/AD-1
1i WINDOW TAG
DOOR TAG
CASEWORK, BASE CABINET W/. COUNTERTOP - AS SELECTED PER I.D., VERIFY
W/. I.D. & OWNER
CASEWORK, UPPER CABINET/SHELVES - AS SELECTED PER I.D., VERIFY W/. I.D. &
OWNER
REFRIGERATOR (REF) & FREEZER (FRZ) - AS SELECTED PER I.D., VERIFY W/.I.D. & OWNER – PROVIDE POWER AND WATER SUPPLY AS REQUIRED
VANITY SINK - AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER – LAVATORY TO HAVE
24” MIN. CLEAR SPACE IN FRONT OF IT.(CPC 402.5) W/. MAXIMUM FLOW RATE OF 1.2 GPM
@ 60 PSI AND MIN. FLOW RATE OF 0.8 GPM @ 20 PSI PER SECTION 4.303.1 OF CALGREEN
BUILT-IN APPLIANCE, DISHWASHER (DW) & TRASH COMPACTOR (TR) - ASSELECTED PER I.D., VERIFY W/. I.D. & OWNER – PROVIDE POWER , WATER SUPPLY
& DRAINAGE PIPE AS REQUIRED
WASHER (W) & DRYER (D) / STACKED (W/D) - AS SELECTED PER I.D., VERIFY W/. I.D.
& OWNER – PROVIDE POWER , GAS, WATER SUPPLY & DRAINAGE AS REQUIRED - THECLOTHES DRYERS VENT SHALL BE OF A RIGID METALLIC MATERIAL AND HAVE A
BACKDRAFT DAMPER (CMC 504.4) AND SHALL NOT EXCEED 14-FEET IN OVERALL LENGTH
WITH MAX. OF TWO (2) 90-DEGREE ELBOW, SUBTRACT 2-FEET FOR EACH ADDITIONAL 90-
DEGREE ELBOW. SEE WASHER & DRYER NOTES, REF. T-1.1.
TOILET - WATER CLOSET SHALL BE IN COMPLIANCE OF SECTION 411.0 OF CPC AND HAS
MAX EFFECTIVE FLUSH RATE OF 1.28 GAL. PER FLUSH (CPC 411.2). WATER CLOSETS CLR.
TO BE 24” IN FRONT AND 15” FROM ITS CENTER TO ANY SIDE WALL OR OBSTRUCTION.
(CPC 402.5 & CRC R307) – REF. CALGREEN NOTES ON T SHTS. FOR MAX FLOW RATE
STAIRS - MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE AN ILLUMINATION LEVEL OF NOT
LESS THAN 1 FOOT CANDLE AS MEASURED AT THE CENTER OF TREADS AND
LANDING WITH ARTIFICIAL LIGHTING (R303.7) - REF. DTL. 3/AD-1
ELEVATOR - PRIVATE RESIDENCE ELEVATOR IN COMPLIANCE W/. ASME A17.1/CSA B44
AS SELECTED PER PLANS, VERIFY W/. OWNER – PROVIDE POWER AS REQUIRED (CRCR321.1)
EXT. STAIRS - MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE ARTIFICIAL LIGHT SOURCE AT
THE TOP LANDING AND FOR STAIR TO THE BASEMENT AT BOTH TOP AND BOTTOMLANDING (R303.8) - REF. DTL. 3/AD-1 -VERIFY TREADS DEPTH AND RISERS HT. W/. CIVIL
AND LANDSCAPE DWGS
WINDOW - AS SPECIFIED, SEE WINDOW SCHEDULE AND GENERAL NOTES ON SHEET A-
7.0 - SHGC & U-FCTOR PER T-24 ENERGY REPORT – SEE SHEET AD-2.0 FOR JAMB,
HEAD AND SILL DETAILS, PROVIDE FLASHING AND WATERPROOFING AT WINDOW
OPENING PER THE WINDOW MFGR. INSTRUCTION AND/OR FLASHING MFGR.
INSTRUCTION PER SECTIONS R609.1 & R703.4 OF CRC
DOORS - AS SPECIFIED, SEE WINDOW SCHEDULE AND GENERAL NOTES ON SHEET A-7.0
- SHGC & U-FCTOR PER T-24 ENERGY REPORT – SEE SHEET AD-2.0 FOR JAMB, HEADAND THRESHOLD DETAILS, PROVIDE FLASHING AND WATERPROOFING AT DOOR
OPENING PER THE DOOR MFGR. INSTRUCTION AND/OR FLASHING MFGR. INSTRUCTION
PER SECTIONS R609.1 & R703.4 OF CRC
FIREPLACE - FACTORY-BUILT DIRECT VENT GAS FIREPLACE W/. SEALED COMBUSTION
(CALGREEN 4.503) - FACTORY-BUILT FIREPLACES, CHIMNEYS AND ALL OF THEIR
COMPONENTS SHALL BE LISTED AND INSTALLED IN ACCORDANCE WITH THEIR LISTING
AND MANUFACTURER'S INSTALLATION INSTRUCTIONS. (CRC R1004.1)
STRUCTURAL STEEL COLUMN - PER STRUCT., REF. STRUTC. DWGS, - PAINT AND
SEAL AS REQUIRED – ARCH. TO APPV. COLOR FOR EXPOSED STEEL COLUMNS
BUILT-IN CLOSET - AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER
STRUCTURAL WOOD POST/COLUMN - PER STRUCT., REF. STRUTC. DWGS, - PAINT,
STAIN AND SEAL AS REQUIRED – ARCH. TO APPV. PAINT COLOR FOR EXPOSED WOOD
POST/COLUMN, IF TO BE STAINED PROVIDE STAINED SAMPLE FOR ARCH, APPROVAL
RECESSED MAIN SERVICE PANEL - 400 AMP MAX. (MAINTAIN 36" CLEAR FROM
FACE OF PANEL TO ANY OBSTRUCTION) – GC TO COORDINATE W/. UTILITY COMPANY
FAU - PROVIDE GAS S.O., POWER, AND VENTING AS REQ'D. BY MFG'R. – INSTALL PER
MFGR. INSTRUCTION
KITCHEN / BAR SINK - AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER – SINK TO
COMPLY W/. REQUIREMENT OF SECTION 420.0 OF CPC AND HAVE A MAX FLOW RATE OF
1.8 GPM @ 60 PSI PER SECTION 4.303.1 OF CALGREEN – TRAP AND VENT FOR ISLAND
SINK AND SIMILAR EQUIPMENT SHALL BE PER SECTION 909.0 OF CPC
KITCHEN RANGE WITH EXHAUST HOOD - AS SELECTED PER I.D., VERIFY W/. I.D. &
OWNER – PROVIDE POWER AND GAS AS REQUIRED - 30” MIN. VERTICAL CLEARANCE TO
ANY COMBUSTIBLE MATERIAL ABV. COOKING TOP (CMC 920.3.2) –EXHAUST HOOD TO
HAVE EXHAUST RATE OF MIN. 100 CFM AND VENT TO OUTDOOR , HOOD DUCTS TO BE
OF METAL WITH SMOOTH INTERIOR FINISH PER SECTION 504.3 OF CMC
CASEWORK, TALL CABINET - AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER
CALL-OUT TAG
REVISION TAG
ROOF/DECK DRAIN - PER CHAPTER 11 OF CPC - SIZE THE DRAIN AND PIPING PER
TABLE 1103.1 AND 1103.2 OF CPC – ROOF DRAIN SHALL HAVE DOMED STRAINER (CPC
1102.2) – REF. DETAIL 11/AD-1.0
OVERFLOW OR EMERGENCY DRAIN - PER CHAPTER 11 OF CPC - COPPER OR EQ.,
INSTALL PER MFGR. INSTRUC., SLOPED TOWARD IN-WALL DRAIN INLETS – SLOPE AND
SIZE PER TABLE 1103.3 OF CPC – REF. DTL. 11/AD-1.0
CHANNEL DRAIN - CHANNEL DRAIN W/. GRATE IN COMPLIANCE W/. CHAPTER 11 OF
CPC - COPPER OR EQ., INSTALL PER MFGR. INSTRUCTION, SLOPED TOWARD IN-WALL
DRAIN INLETS – SLOPE AND SIZE PER TABLE 1103.3 OF CPC – REF. DETAIL 11/AD-1.0,
ARCH. TO APPV. GRATE COLOR AND TYPE
A/C CONDENSER / HEAT PUMP - TO BE IN COMPLIANCE OF SECTION 307.3 OF CPC
AS SELECTED, VERIFY W/. OWNER - SIZE TBD, SEE T-24 ENERGY REPORT FOR MORE
INFO – PROVIDE POWER AND SOUND DAMPENING PAD AS REQ’D. – INSTALL AND
MAINTAIN REQUIRED CLEARANCES PER MFGR. INSTRUCTION
05.06 ACM PANEL FASCIAREF. MAT. SCHEDULE. ARCH. TO APPV. JOINT AND SEAM LAYOUT
05.07 SLANTED ACM PANEL FASCIA
REF. DETAILS AND MAT. SCHEDULE. ARCH. TO APPV. JOINT AND SEAM LAYOUT
06.48 DEPRESS STRUCTURE FOR FLUSH SHOWER CONDITION
COORD. WITH I.D. & GENERAL CONTRACTOR, REF. STRUCT. DWGS.
09.24 TILE/STONE PAVERS
ON CONCRETE SETTING BED O/ WATERPROOF MEMBRANE REF. MAT. SCHEDULE (CLASS 'A' ASSEMBLY)
09.28 STANDING SEAM METAL ROOFING
REF. MAT. SCHEDULE SHT. A-4.0
09.31 FLAT COOL ROOF
CLASS 'A' - COLOR AS SELECTED - TPO MEMBRANE - REF. MAT. SCHEDULE SHT. A-4.0
10.01 EXTERIOR GLASS GUARDRAIL
TEMPERED & LAMINATED - MIN. 42" HIGH - 4" MAX. SPHERE OPENING, REF. DTL. 4/AD-1
10.04 INTERIOR GLASS GUARDRAIL
MIN. 42" HIGH - MATERIAL AS SELECTED, <4" MAX. SPHERE OPENING, REF. DTL. 4/AD-1
10.07 STAIRS
MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS THAN 1 FOOT CANDLE(CBC 1205.4) REF. DTL. 3/AD-1
22.05 SHOWER
PROVIDE TILE W/. CEMENT BACKING MIN. 72" HIGH (R307.2)
22.19 CUSTOM RECESSED GUTTER/ROOF DRAIN
ROOFING CONTRACTOR COORD. W/. FLASHING INSTALLER - VERIFY SIZE, LOC'N & APPLICATION OF DRAIN W/. ARCH
PRIOR TO ORDERING
22.20 CUSTOM SHOWER SEAT
SEAT PER I.D.
SCALE: 1/4" = 1'-0"1THIRD LEVEL FLOOR PLAN
BRANDON ARCHITECTS
DATE
A-2.2
PROJECT CONTACT
JEFF VAN VOORHIS, AIA
PROJECT NAME
PROJECT ADDRESS
908 W. OCEANFRONT
NEWPORT BEACH, CA 92661
OWNER INFORMATION
908 NB PROPERTY MANAGEMENT LLC
3717 EUCLID AVE.
DALLAS, TX
PROJECT STATUS
SECOND CHECK
PLAN CHECK NO.
TBD
REVISIONS
NO.
DATE
5/28/2021 HARVEY RESIDENCEFIRST & SECOND
LEVEL DIMENSION
PLAN
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
REVISIONS
These documents are the property of BRANDON
ARCHITECTS INC., and are not to be duplicated,
altered or utilized in any ay by any other party
without the expressed authorization of
BRANDON ARCHITECTS. Any unauthorized
duplication or alteration of these documents by
any party is a violation of BRANDON
ARCHITECTS expressed common law copyright
and other property rights thereto, and is subject
to full civil liabilities and penalties. These plans
are also not to be assigned to any third party
without obtaining written authorization and
expressed permission by BRANDON
ARCHITECTS, who shall then be held harmless
and absolved of any liability regarding any use
of these documents by such third party whether
depicted or implied hereon.A GENERAL NOTES
B ANNOTATION LEGEND
DIMENSION NOTE:ALL DIMENSIONS ARE TO FACE OF SHEATHING (EXT. WALLS) OR FACE OF STRUCTURE (F.O.S.) TYP. U.N.O. ROUNDED TO THE NEAREST 1/8" AND
INTERIOR PARTITIONS ARE DIMENSIONED FROM FACE OF STRUCTURE TO FACE OF STRUCTURE (F.O.S.) U.N.O. - CONTACT ARCHITECT IN
WRITING FOR ANY CLARIFICATION OF NOTED DIMENSIONS, DO NOT SCALE PLANS.
ROUGH FRAMING:
ALL EXTERIOR WALLS TO BE FRAMED W/. 2X6 STUD MIN. U.N.O.USE 2X6 MINIMUM STUDS FOR PLUMBING WALLS
SECOND AND THIRD FLOOR PLYWOOD TO BE 1-1/8"
ENTIRE EXTERIOR TO BE SHEATHED WITH 1/2" PLYWOOD
DOORS AND WINDOWS WILL TYPICALLY BE RECESSED FROM EXTERIOR WALL PLANE. VERIFY ALL ROUGH OPENING DIMENSIONS WITH DOORAND WINDOW MFGR. ROUGH OPENING MAY NEED TO BE OVERSIZED TO ACCOUNT FOR ADDITIONAL FRAMING. SEE SHT. AD-2.0 FOR TYP.
RECESSED CONDITIONS.
GARAGE FLOOR:
GARAGE FLOOR SURFACES SHALL BE OF APPROVED NONCOMBUSTIBLE MATERIAL.THE AREA OF FLOOR USED FOR PARKING OF AUTOMOBILES
OR OTHER VEHICLES SHALL BE SLOPED TO FACILITATE THE MOVEMENT OF LIQUIDS TO A DRAIN OR TOWARD THE MAIN VEHICLE ENTRY
DOORWAY. (R309.1)
PLUMBING:
1. SUPPORT ALL WALL-HUNG FIXTURES WITH METAL SUPPORTING MEMBERS TO PREVENT ANY STRAIN TRANSMISSION TO THE CONNECTIONS.
FRAMING AFFIXED SUPPORTS FOR OFF-THE-FLOOR WATER CLOSETS WITH CONCEALED TANKS SHALL COMPLY WITH ASME A112.6.2. SECURE
FLUSH TANK AND SIMILAR APPURTENANCES WITH APPROVED NON-CORROSIVE SCREW OR BOLTS. (CPC 402.5)
2. THE NET AREA OF THE SHOWER ENCLOSURE SHALL BE 1,024 SQ. INCHES (7.1 SQ. FT.) OR MORE IN THE CLEAR FLOOR AREA, AND SHALL
ALSO BE CAPABLE OF ENCOMPASSING A 30-INCH DIAMETER CIRCLE. (CPC 408.6)
3. THE WATER HEATER BURNER AND BURNER-IGNITION DEVICE TO BE AT LEAST 18-INCHES ABOVE THE FLOOR, IF LOCATED IN A GARAGE AND
IN ADJACENT SPACES THAT OPEN TO THE GARAGE. FOR WATER HEATER IN THE GARAGE OR OTHER AREAS SUBJECT TO MECHANICAL DAMAGE
PROVIDE A PROTECTIVE BARRIER OR ELEVATE THE APPLIANCE TO BE OUT OF THE NORMAL PATH OF THE VEHICLE. (CPC 507.13)
4. ANCHOR OR STRAP THE WATER HEATER(S) TO RESIST HORIZ. DISPLACEMENT DUE TO THE EARTHQUAKE. STRAPPING SHOULD BE AT THE
UPPER AND LOWER ONE THIRD (1/3) POINTS OF THE APPLIANCE HEIGHT. MAINTAIN A MIN. 4-INCHES ABOVE THE CONTROLS WITH STRAPPING
AT LOWER POINT.
WOOD OR WOODBASED PRODUCTS NOTE:
WOOD OR WOODBASE PRODUCT SHALL BE OF A NATURAL DURABLE OR PRESERVATIVE-TREADED WOOD IN ACCORDANCE WITH AWPA U1 FOR
THE SPECIES, PRODUCT, PRESERVATIVE AND END USE IN THE FOLLOWING LOCATIONS:
1. WOOD JOISTS OR THE BOTTOM OF A WOOD STRUCTURAL FLOOR WHEN CLOSER THAN 18 INCHES (457 MM) OR WOOD GIRDERS WHEN
CLOSER THAN 12 INCHES (305 MM) TO THE EXPOSED GROUND IN CRAWL SPACES OR UNEXCAVATED AREA LOCATED WITHIN THE PERIPHERY
OF THE BUILDING FOUNDATION.
2. WOOD FRAMING MEMBERS THAT REST ON CONCRETE OR MASONRY EXTERIOR FOUNDATION WALLS AND ARE LESS THAN 8 INCHES (203
MM) FROM THE EXPOSED GROUND.
3. SILLS AND SLEEPERS ON A CONCRETE OR MASONRY SLAB THAT IS IN DIRECT CONTACT WITH THE GROUND UNLESS SEPARATED FROM
SUCH SLAB BY AN IMPERVIOUS MOISTURE BARRIER.
4. THE ENDS OF WOOD GIRDERS ENTERING EXTERIOR MASONRY OR CONCRETE WALLS HAVING CLEARANCES OF LESS THAN 1/2 INCH (12.7
MM) ON TOPS, SIDES AND ENDS.
5. WOOD SIDING, SHEATHING AND WALL FRAMING ON THE EXTERIOR OF A BUILDING HAVING A CLEARANCE OF LESS THAN 6 INCHES (152 MM)
FROM THE GROUND OR LESS THAN 2 INCHES (51 MM) MEASURED VERTICALLY FROM CONCRETE STEPS, PORCH SLABS, PATIO SLABS AND
SIMILAR HORIZONTAL SURFACES EXPOSED TO THE WEATHER.
6. WOOD STRUCTURAL MEMBERS SUPPORTING MOISTURE-PERMEABLE FLOORS OR ROOFS THAT ARE EXPOSED TO THE WEATHER, SUCH AS
CONCRETE OR MASONRY SLABS, UNLESS SEPARATED FROM SUCH FLOORS OR ROOFS BY AN IMPERVIOUS MOISTURE BARRIER.
7. WOOD FURRING STRIPS OR OTHER WOOD FRAMING MEMBERS ATTACHED DIRECTLY TO THE INTERIOR OF EXTERIOR MASONRY WALLS OR
CONCRETE WALLS BELOW GRADE EXCEPT WHERE AN APPROVED VAPOR RETARDER IS APPLIED BETWEEN THE WALL AND THE FURRING STRIPS
OR FRAMING MEMBERS.
*HERS VERIFICATION REQUIRED- REFERENCE T-24.1
REF
W/D.
DW
TR
FRZ
3-CAR GARAGE
SAND ROOM
ELEV.
PWDR.
GREAT ROOM
DINING
KITCHEN
LOUNGE
PANTRY
UP
2'-1 1/4"2'-6 3/8"12'-0 5/8"20'-8 7/8"5'-6 7/8"4'-9 1/2"10'-3 1/4"7'-0"1'-5 1/2"8'-5 7/8"1'-7"
43'-0"33'-7 1/8"
12'-0"76'-7 1/8"5 3/4"
2'-1 1/4"4'-9 1/2"7'-8"5'-2 3/4"7'-11"8'-3 1/2"
36'-0"7'-4 1/8"8'-7 3/8"24'-7 1/2"
16'-4 1/2"76'-7 1/8"4 7/8"1'-5"7 5/8"9'-0"1'-8 3/8"18'-0"2'-0 5/8"2'-0 5/8"30'-9"3'-2"32'-9 5/8"4'-0"5'-3"26'-6"1'-10 5/8"33'-7 5/8"3'-2"33'-7 5/8"3'-2"8'-0"
F.Y.S.B.3'-0"S.Y.S.B.3'-0"S.Y.S.B.3'-2"5'-9 5/8"3'-7 1/8"7'-0 3/4"9'-0 3/4"8'-1 3/8"3'-2"30'-0 3/8"3'-1 1/4"3'-2"8'-4 3/4"6'-0 3/4"2'-5 3/4"15'-10 1/2"4'-0"7'-3 3/8"4'-0"2'-5 3/8"5'-9 7/8"1'-5 3/8"2'-7 1/8"2'-9 5/8"1'-6 7/8"4'-0 1/4"
4'-0"CLR.4'-0"CLR.1'-0"TYP.4'-3 3/8"CLR.4'-0"CLR.4'-0"CLR.
2'-5 3/8"5'-3 1/8"1'-11 3/8"2'-7 3/4"7'-11 1/4"1'-0"10 5/8"2'-10"1'-3 1/2"2'-0 5/8"PER I.D.11"6 3/4"8'-0 5/8"3'-9 1/8"20'-10 3/8"
ENTRY
STAIRS
UP
D
W
RETREAT/OFFICE STAIRS
ELEV.BED #2
BED #3
BATH #3
W.I.C.
BATH #4
BATH #2
BED #4
LNDRY.
MASTER W.I.C.MASTER BATH
W/C.
MASTER SUITE
BED #5
BATH #5
W.I.C.
MECH.
DN.
5'-7 1/2"4'-7"9'-7"3'-11"
4'-9 3/4"23'-8 5/8"12'-3 3/8"7'-4 1/8"8'-10 1/2"24'-3 1/4"
16'-4 1/2"76'-5 7/8"6 1/8"
2'-1 1/4"2'-6 5/8"10'-3"3'-0 7/8"6'-10 3/4"6'-2 3/4"4'-2 3/8"3'-9 5/8"5'-10 5/8"5'-1 3/4"6'-9 5/8"4'-8 1/2"13'-6 1/4"1'-4"
4'-9 3/4"17'-11 3/4"13'-1 1/2"8'-0"11'-0 3/8"11'-6"14'-10 1/4"
12'-0"76'-5 7/8"6 7/8"4'-3 5/8"10'-3 5/8"3'-2"36'-9 5/8"14'-7 1/4"6'-9"12'-4 3/8"6 3/4"8'-3 3/4"1'-6"7'-11"2'-0 1/4"9'-9 1/4"1'-8 3/4"1'-4"4'-7"10"13'-3"1'-4 3/8"11'-9 1/4"2'-0"18'-8"14'-8 3/8"3'-0"33'-4 3/8"3'-3 5/8"8'-0"
F.Y.S.B.3'-0"S.Y.S.B.3'-0"S.Y.S.B.10'-2 5/8"2'-1 3/4"3'-2"8'-6 3/4"5'-8 1/8"2'-4 3/4"4'-4 3/4"4'-6"8'-1 3/8"3'-2"2'-1 1/4"1'-8 7/8"1'-9 3/8"
7'-4 5/8"2'-10"1'-11 5/8"5'-10 3/4"2'-7 1/2"9'-7 3/8"3'-2"11'-7 1/8"2'-4 3/4"2'-9 1/8"4'-4 5/8"3'-8 3/8"8'-9 5/8"3'-2"2'-10"7'-1 5/8"5'-3 3/4"3'-2"2'-4 1/8"2'-8 1/4"2'-4 1/8"2'-0 5/8"6'-0 3/8"6'-7"3'-2"8'-5"2'-8 5/8"2'-0 5/8"4'-3 7/8"3'-8 1/8"6'-11 3/8"2'-2 1/4"1'-10 3/4"2'-10 1/8"2'-6 5/8"6'-1 1/4"2'-5"1'-11 5/8"3'-2"6'-5 5/8"4'-3"3'-10 7/8"2'-0"4'-4 3/4"4'-7 7/8"1'-7 3/4"2'-0 1/4"4'-4 1/2"3'-1"3'-2"2'-5 3/4"6'-1"8'-0 3/4"8"4'-10"3'-2 3/4"
4'-1 1/8"1'-9 5/8"
1'-0 5/8"3'-0"7'-3"3'-0"1'-6 7/8"
15'-10 1/2"
6'-2 3/4"6'-2 3/4"
4'-8 1/2"2'-2 7/8"3'-2"4'-4"2'-2 1/4"2'-0 1/2"5'-10 3/4"2'-2"4'-6 3/4"4 1/8"4'-9 1/4"
2'-3 7/8"
2'-0 7/8"10'-5 5/8"6 3/8"
5 3/4"2'-6"7'-3 1/4"2'-6"5 3/4"
13'-2 3/4"
6'-8"3'-9 5/8"
ROOM NAME
D W / DW
DW TR
1
15'-6"
01.13
1
2x4 STUD WALL
2x10 STUD WALL
EXT. POCKET DOOR WALL - TYP. 2X6 EXT. FRMG. AND 2X4 INTERIOR FRAMING
W/. DOUBLE TOP PLATE AND SINGLE SILL PLATE U.N.O., MIN. AIR SPACE/DOORPOCKET TO BE VERIFIED W/. DOOR MFGR. - STUDS MIN. SPACING PER STRUCT.
AND EXT. FINISH MFGR. INSTRUCTION AND/OR LISTING – SEE EXT. WALL DETAILS
AND STRUCT. DWGS
SLAB/FRAMING DEPRESSION - SEE STRUCT. DWGS. FOR THE RECESSION
DETAILS - FOR RECESSION SPECIFIC TO EQUIPMENT OR ASSEMBLY VERIFY THEREQUIRED RECESSION W/. MFGR. OR FABRICATOR – SHOWER RECESSION TO BE
VERIFIED W/. I.D.
VANITY SINK - AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER – LAVATORY TO HAVE
24” MIN. CLEAR SPACE IN FRONT OF IT.(CPC 402.5) W/. MAXIMUM FLOW RATE OF 1.2GPM @ 60 PSI AND MIN. FLOW RATE OF 0.8 GPM @ 20 PSI PER SECTION 4.303.1 OF
CALGREEN
KITCHEN / BAR SINK - AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER – SINK TO
COMPLY W/. REQUIREMENT OF SECTION 420.0 OF CPC AND HAVE A MAX FLOW RATE OF
1.8 GPM @ 60 PSI PER SECTION 4.303.1 OF CALGREEN – TRAP AND VENT FOR ISLAND
SINK AND SIMILAR EQUIPMENT SHALL BE PER SECTION 909.0 OF CPC
KITCHEN RANGE WITH EXHAUST HOOD - AS SELECTED PER I.D., VERIFY W/. I.D. &
OWNER – PROVIDE POWER AND GAS AS REQUIRED - 30” MIN. VERTICAL CLEARANCE TO
ANY COMBUSTIBLE MATERIAL ABV. COOKING TOP (CMC 920.3.2) –EXHAUST HOOD TO
HAVE EXHAUST RATE OF MIN. 100 CFM AND VENT TO OUTDOOR , HOOD DUCTS TO BE
OF METAL WITH SMOOTH INTERIOR FINISH PER SECTION 504.3 OF CMC
ROOM TAG
KEYNOTE TAG
SPOT ELEVATION
1i WINDOW TAG
DOOR TAG
REVISION TAG
BUILT-IN APPLIANCE, DISHWASHER (DW) & TRASH COMPACTOR (TR) - AS
SELECTED PER I.D., VERIFY W/. I.D. & OWNER – PROVIDE POWER , WATER SUPPLY
& DRAINAGE PIPE AS REQUIRED
TOILET - WATER CLOSET SHALL BE IN COMPLIANCE OF SECTION 411.0 OF CPC AND HAS
MAX EFFECTIVE FLUSH RATE OF 1.28 GAL. PER FLUSH (CPC 411.2). WATER CLOSETS CLR.
TO BE 24” IN FRONT AND 15” FROM ITS CENTER TO ANY SIDE WALL OR OBSTRUCTION.
(CPC 402.5 & CRC R307) – REF. CALGREEN NOTES ON T SHTS. FOR MAX FLOW RATE
FIREPLACE - FACTORY-BUILT DIRECT VENT GAS FIREPLACE W/. SEALED COMBUSTION
(CALGREEN 4.503) - FACTORY-BUILT FIREPLACES, CHIMNEYS AND ALL OF THEIR
COMPONENTS SHALL BE LISTED AND INSTALLED IN ACCORDANCE WITH THEIR LISTING
AND MANUFACTURER'S INSTALLATION INSTRUCTIONS. (CRC R1004.1)
RECESSED MAIN SERVICE PANEL - 400 AMP MAX. (MAINTAIN 36" CLEAR FROM
FACE OF PANEL TO ANY OBSTRUCTION) – GC TO COORDINATE W/. UTILITY COMPANY
FAU - PROVIDE GAS S.O., POWER, AND VENTING AS REQ'D. BY MFG'R. – INSTALL PER
MFGR. INSTRUCTION
ROOF/DECK DRAIN - PER CHAPTER 11 OF CPC - SIZE THE DRAIN AND PIPING PER
TABLE 1103.1 AND 1103.2 OF CPC – ROOF DRAIN SHALL HAVE DOMED STRAINER (CPC
1102.2) – REF. DETAIL 11/AD-1.0
OVERFLOW OR EMERGENCY DRAIN - PER CHAPTER 11 OF CPC - COPPER OR EQ.,
INSTALL PER MFGR. INSTRUC., SLOPED TOWARD IN-WALL DRAIN INLETS – SLOPE AND
SIZE PER TABLE 1103.3 OF CPC – REF. DTL. 11/AD-1.0
CHANNEL DRAIN - CHANNEL DRAIN W/. GRATE IN COMPLIANCE W/. CHAPTER 11 OF
CPC - COPPER OR EQ., INSTALL PER MFGR. INSTRUCTION, SLOPED TOWARD IN-WALL
DRAIN INLETS – SLOPE AND SIZE PER TABLE 1103.3 OF CPC – REF. DETAIL 11/AD-1.0,
ARCH. TO APPV. GRATE COLOR AND TYPE
A/C CONDENSER / HEAT PUMP - TO BE IN COMPLIANCE OF SECTION 307.3 OF CPC
AS SELECTED, VERIFY W/. OWNER - SIZE TBD, SEE T-24 ENERGY REPORT FOR MORE
INFO – PROVIDE POWER AND SOUND DAMPENING PAD AS REQ’D. – INSTALL AND
MAINTAIN REQUIRED CLEARANCES PER MFGR. INSTRUCTION
2x6 STUD WALL
2x8 STUD WALL
STUDS MIN. SPACING PER STRUCT. AND EXT. FINISH MFGR.
INSTRUCTION AND/OR LISTING – SEE EXT. WALL DETAILS AND
STRUCT. DWGS
CONCRETE WALL - 12” REINFORCED CAST IN PLACE CONCRETE WALL TYP. U.N.O.
PER STRUCT., REF. STRCUTC. DWGS. – FOR BASEMENT/RETAINING CONCRETE WALL
PROVIDE WATERPROOFING OR DAMPPROOFING AND DRAINAGE AS REQUIRED PER
SECTION R406.1 & R406.2, REF. SOILS REPORT,WATERPROOFING & DAMPROOFING
NOTES ON SHEET T-1.1 – EXPOSED SURFACES TO HAVE TROWELED SMOOTH FINISH
WITH A LIGHT GRAY COLOR, PROVIDE SAMPLE FOR ARCH. APPROVAL
STRUCTURAL STEEL COLUMN - PER STRUCT., REF. STRUTC. DWGS, - PAINT AND
SEAL AS REQUIRED – ARCH. TO APPV. COLOR FOR EXPOSED STEEL COLUMNS
STRUCTURAL WOOD POST/COLUMN - PER STRUCT., REF. STRUTC. DWGS, - PAINT,
STAIN AND SEAL AS REQUIRED – ARCH. TO APPV. PAINT COLOR FOR EXPOSED WOOD
POST/COLUMN, IF TO BE STAINED PROVIDE STAINED SAMPLE FOR ARCH, APPROVAL
WASHER (W) & DRYER (D) / STACKED (W/D) - AS SELECTED PER I.D., VERIFY W/. I.D.
& OWNER – PROVIDE POWER , GAS, WATER SUPPLY & DRAINAGE AS REQUIRED - THE
CLOTHES DRYERS VENT SHALL BE OF A RIGID METALLIC MATERIAL AND HAVE A
BACKDRAFT DAMPER (CMC 504.4) AND SHALL NOT EXCEED 14-FEET IN OVERALL LENGTH
WITH MAX. OF TWO (2) 90-DEGREE ELBOW, SUBTRACT 2-FEET FOR EACH ADDITIONAL 90-
DEGREE ELBOW. SEE WASHER & DRYER NOTES, REF. T-1.1.
SEE SHEET AD-2.0 FOR THE TYPICAL DEPRESSION OF DOORS AND
WINDOWS, VERIFY ALL THE DEPRESSION W/. MFGR.
VERTICAL STORM DRAIN PIPE IN-WALL ( ) / OVERFLOW ( )- MTL. PIPE PER
CHAPTER 11 OF CPC, SIZE PER TABLE 1103.1 (MIN. 2” DIA. PIPE & TYP. 3” DIA. PIPE) – SEE
CIVIL DWGS. FOR TERMINATION DTLS. ABV. OR BLW. GROUND. VERIFY ALL TERMINATION
POINTS, TYPE AND DETAILS W/. CIVIL PRIOR TO POURING THE CONCRETE SLAB
TANKLESS WATER HEATER - SIZE AND INSTALL PER CHAPTER 5 OF CPC AND MFGR.
INSTRUCTION, VERIFY THE SIZING W/. T-24 ENERGY REPORT – THE WATER HEATER
BURNER AND BURNER-IGNITION DEVICE TO BE AT LEAST 18-INCHES ABOVE THE FLOOR,
IF LOCATED IN A GARAGE AND IN ADJACENT SPACES THAT OPEN TO THE GARAGE. FOR
WATER HEATER IN THE GARAGE OR OTHER AREAS SUBJECT TO MECHANICAL DAMAGE
PROVIDE A PROTECTIVE BARRIER OR ELEVATE THE APPLIANCE TO BE OUT OF THE
NORMAL PATH OF THE VEHICLE. (CPC 507.13)
SCALE: 1/4" = 1'-0"1FIRST LEVEL DIMENSION PLAN
SCALE: 1/4" = 1'-0"2SECOND LEVEL DIMENSION PLAN
BRANDON ARCHITECTS
DATE
A-2.3
PROJECT CONTACT
JEFF VAN VOORHIS, AIA
PROJECT NAME
PROJECT ADDRESS
908 W. OCEANFRONT
NEWPORT BEACH, CA 92661
OWNER INFORMATION
908 NB PROPERTY MANAGEMENT
LLC
DEREK & MEGAN HARVEY
3717 EUCLID AVE.
DALLAS, TX
PROJECT STATUS
SECOND CHECK
PLAN CHECK NO.
TBD
REVISIONS
NO.
DATE
04/01/21 HARVEY RESIDENCETHIRD LEVEL
DIMENSION PLAN
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
REVISIONS
These documents are the property of BRANDON
ARCHITECTS INC., and are not to be duplicated,
altered or utilized in any ay by any other party
without the expressed authorization of
BRANDON ARCHITECTS. Any unauthorized
duplication or alteration of these documents by
any party is a violation of BRANDON
ARCHITECTS expressed common law copyright
and other property rights thereto, and is subject
to full civil liabilities and penalties. These plans
are also not to be assigned to any third party
without obtaining written authorization and
expressed permission by BRANDON
ARCHITECTS, who shall then be held harmless
and absolved of any liability regarding any use
of these documents by such third party whether
depicted or implied hereon.
DN.
46'-4 1/4"27'-6 3/4"15'-1 7/8"
1'-7 7/8"1'-8 3/8"
10'-6 7/8"1'-10 1/4"5'-4 3/4"6'-4 5/8"4'-2 1/4"15'-0"4'-6 1/2"5'-11 1/8"5'-0"29'-7 7/8"5'-3 3/4"14'-8 1/2"6'-4 3/4"5'-7 3/8"4'-2"5'-1"26'-8 5/8"8'-2"1'-7 3/4"7'-4 1/8"6 1/2"8'-0 1/4"6 5/8"
20'-1 3/8"14'-5 3/4"8'-11 7/8"9'-1 3/8"9'-5 3/8"
2'-6 1/8"2'-6"4'-5 1/4"
50'-8 3/4"27'-6 3/4"15'-1"
20'-0 3/8"14'-6 3/4"15'-9 3/8"11'-9 3/8"30'-5 1/4"8'-0"
F.Y.S.B.3'-0"S.Y.S.B.3'-0"S.Y.S.B.5'-11 5/8"5'-3 3/4"5'-1"2'-4 3/4"4'-3"5'-10 3/4"2'-6 1/8"6"
2'-6"8'-2 1/8"2'-6"
6"
14'-2 1/8"7'-7 3/8"4'-3 1/8"1'-8 3/4"3'-11 1/2"
2'-10 1/8"2'-6 5/8"4'-1 7/8"
2'-2 3/4"
BONUS ROOM ELEV.
MECH.
MECH.
BATH #6
5'-3"19'-3 1/4"9'-9 5/8"5'-7 3/4"STAIRS
A GENERAL NOTES
B ANNOTATION LEGEND
DIMENSION NOTE:ALL DIMENSIONS ARE TO FACE OF SHEATHING (EXT. WALLS) OR FACE OF STRUCTURE (F.O.S.) TYP. U.N.O. ROUNDED TO THE NEAREST 1/8" AND
INTERIOR PARTITIONS ARE DIMENSIONED FROM FACE OF STRUCTURE TO FACE OF STRUCTURE (F.O.S.) U.N.O. - CONTACT ARCHITECT IN
WRITING FOR ANY CLARIFICATION OF NOTED DIMENSIONS, DO NOT SCALE PLANS.
ROUGH FRAMING:
ALL EXTERIOR WALLS TO BE FRAMED W/. 2X6 STUD MIN. U.N.O.USE 2X6 MINIMUM STUDS FOR PLUMBING WALLS
SECOND AND THIRD FLOOR PLYWOOD TO BE 1-1/8"
ENTIRE EXTERIOR TO BE SHEATHED WITH 1/2" PLYWOOD
DOORS AND WINDOWS WILL TYPICALLY BE RECESSED FROM EXTERIOR WALL PLANE. VERIFY ALL ROUGH OPENING DIMENSIONS WITH DOORAND WINDOW MFGR. ROUGH OPENING MAY NEED TO BE OVERSIZED TO ACCOUNT FOR ADDITIONAL FRAMING. SEE SHT. AD-2.0 FOR TYP.
RECESSED CONDITIONS.
GARAGE FLOOR:
GARAGE FLOOR SURFACES SHALL BE OF APPROVED NONCOMBUSTIBLE MATERIAL.THE AREA OF FLOOR USED FOR PARKING OF AUTOMOBILES
OR OTHER VEHICLES SHALL BE SLOPED TO FACILITATE THE MOVEMENT OF LIQUIDS TO A DRAIN OR TOWARD THE MAIN VEHICLE ENTRY
DOORWAY. (R309.1)
PLUMBING:
1. SUPPORT ALL WALL-HUNG FIXTURES WITH METAL SUPPORTING MEMBERS TO PREVENT ANY STRAIN TRANSMISSION TO THE CONNECTIONS.
FRAMING AFFIXED SUPPORTS FOR OFF-THE-FLOOR WATER CLOSETS WITH CONCEALED TANKS SHALL COMPLY WITH ASME A112.6.2. SECURE
FLUSH TANK AND SIMILAR APPURTENANCES WITH APPROVED NON-CORROSIVE SCREW OR BOLTS. (CPC 402.5)
2. THE NET AREA OF THE SHOWER ENCLOSURE SHALL BE 1,024 SQ. INCHES (7.1 SQ. FT.) OR MORE IN THE CLEAR FLOOR AREA, AND SHALL
ALSO BE CAPABLE OF ENCOMPASSING A 30-INCH DIAMETER CIRCLE. (CPC 408.6)
3. THE WATER HEATER BURNER AND BURNER-IGNITION DEVICE TO BE AT LEAST 18-INCHES ABOVE THE FLOOR, IF LOCATED IN A GARAGE AND
IN ADJACENT SPACES THAT OPEN TO THE GARAGE. FOR WATER HEATER IN THE GARAGE OR OTHER AREAS SUBJECT TO MECHANICAL DAMAGE
PROVIDE A PROTECTIVE BARRIER OR ELEVATE THE APPLIANCE TO BE OUT OF THE NORMAL PATH OF THE VEHICLE. (CPC 507.13)
4. ANCHOR OR STRAP THE WATER HEATER(S) TO RESIST HORIZ. DISPLACEMENT DUE TO THE EARTHQUAKE. STRAPPING SHOULD BE AT THE
UPPER AND LOWER ONE THIRD (1/3) POINTS OF THE APPLIANCE HEIGHT. MAINTAIN A MIN. 4-INCHES ABOVE THE CONTROLS WITH STRAPPING
AT LOWER POINT.
WOOD OR WOODBASED PRODUCTS NOTE:
WOOD OR WOODBASE PRODUCT SHALL BE OF A NATURAL DURABLE OR PRESERVATIVE-TREADED WOOD IN ACCORDANCE WITH AWPA U1 FOR
THE SPECIES, PRODUCT, PRESERVATIVE AND END USE IN THE FOLLOWING LOCATIONS:
1. WOOD JOISTS OR THE BOTTOM OF A WOOD STRUCTURAL FLOOR WHEN CLOSER THAN 18 INCHES (457 MM) OR WOOD GIRDERS WHEN
CLOSER THAN 12 INCHES (305 MM) TO THE EXPOSED GROUND IN CRAWL SPACES OR UNEXCAVATED AREA LOCATED WITHIN THE PERIPHERY
OF THE BUILDING FOUNDATION.
2. WOOD FRAMING MEMBERS THAT REST ON CONCRETE OR MASONRY EXTERIOR FOUNDATION WALLS AND ARE LESS THAN 8 INCHES (203
MM) FROM THE EXPOSED GROUND.
3. SILLS AND SLEEPERS ON A CONCRETE OR MASONRY SLAB THAT IS IN DIRECT CONTACT WITH THE GROUND UNLESS SEPARATED FROM
SUCH SLAB BY AN IMPERVIOUS MOISTURE BARRIER.
4. THE ENDS OF WOOD GIRDERS ENTERING EXTERIOR MASONRY OR CONCRETE WALLS HAVING CLEARANCES OF LESS THAN 1/2 INCH (12.7
MM) ON TOPS, SIDES AND ENDS.
5. WOOD SIDING, SHEATHING AND WALL FRAMING ON THE EXTERIOR OF A BUILDING HAVING A CLEARANCE OF LESS THAN 6 INCHES (152 MM)
FROM THE GROUND OR LESS THAN 2 INCHES (51 MM) MEASURED VERTICALLY FROM CONCRETE STEPS, PORCH SLABS, PATIO SLABS AND
SIMILAR HORIZONTAL SURFACES EXPOSED TO THE WEATHER.
6. WOOD STRUCTURAL MEMBERS SUPPORTING MOISTURE-PERMEABLE FLOORS OR ROOFS THAT ARE EXPOSED TO THE WEATHER, SUCH AS
CONCRETE OR MASONRY SLABS, UNLESS SEPARATED FROM SUCH FLOORS OR ROOFS BY AN IMPERVIOUS MOISTURE BARRIER.
7. WOOD FURRING STRIPS OR OTHER WOOD FRAMING MEMBERS ATTACHED DIRECTLY TO THE INTERIOR OF EXTERIOR MASONRY WALLS OR
CONCRETE WALLS BELOW GRADE EXCEPT WHERE AN APPROVED VAPOR RETARDER IS APPLIED BETWEEN THE WALL AND THE FURRING STRIPS
OR FRAMING MEMBERS.
*HERS VERIFICATION REQUIRED- REFERENCE T-24.1
ROOM NAME
D W / DW
DW TR
1
15'-6"
01.13
1
2x4 STUD WALL
2x10 STUD WALL
EXT. POCKET DOOR WALL - TYP. 2X6 EXT. FRMG. AND 2X4 INTERIOR FRAMING
W/. DOUBLE TOP PLATE AND SINGLE SILL PLATE U.N.O., MIN. AIR SPACE/DOORPOCKET TO BE VERIFIED W/. DOOR MFGR. - STUDS MIN. SPACING PER STRUCT.
AND EXT. FINISH MFGR. INSTRUCTION AND/OR LISTING – SEE EXT. WALL DETAILS
AND STRUCT. DWGS
SLAB/FRAMING DEPRESSION - SEE STRUCT. DWGS. FOR THE RECESSION
DETAILS - FOR RECESSION SPECIFIC TO EQUIPMENT OR ASSEMBLY VERIFY THEREQUIRED RECESSION W/. MFGR. OR FABRICATOR – SHOWER RECESSION TO BE
VERIFIED W/. I.D.
VANITY SINK - AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER – LAVATORY TO HAVE
24” MIN. CLEAR SPACE IN FRONT OF IT.(CPC 402.5) W/. MAXIMUM FLOW RATE OF 1.2GPM @ 60 PSI AND MIN. FLOW RATE OF 0.8 GPM @ 20 PSI PER SECTION 4.303.1 OF
CALGREEN
KITCHEN / BAR SINK - AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER – SINK TO
COMPLY W/. REQUIREMENT OF SECTION 420.0 OF CPC AND HAVE A MAX FLOW RATE OF
1.8 GPM @ 60 PSI PER SECTION 4.303.1 OF CALGREEN – TRAP AND VENT FOR ISLAND
SINK AND SIMILAR EQUIPMENT SHALL BE PER SECTION 909.0 OF CPC
KITCHEN RANGE WITH EXHAUST HOOD - AS SELECTED PER I.D., VERIFY W/. I.D. &
OWNER – PROVIDE POWER AND GAS AS REQUIRED - 30” MIN. VERTICAL CLEARANCE TO
ANY COMBUSTIBLE MATERIAL ABV. COOKING TOP (CMC 920.3.2) –EXHAUST HOOD TO
HAVE EXHAUST RATE OF MIN. 100 CFM AND VENT TO OUTDOOR , HOOD DUCTS TO BE
OF METAL WITH SMOOTH INTERIOR FINISH PER SECTION 504.3 OF CMC
ROOM TAG
KEYNOTE TAG
SPOT ELEVATION
1i WINDOW TAG
DOOR TAG
REVISION TAG
BUILT-IN APPLIANCE, DISHWASHER (DW) & TRASH COMPACTOR (TR) - AS
SELECTED PER I.D., VERIFY W/. I.D. & OWNER – PROVIDE POWER , WATER SUPPLY
& DRAINAGE PIPE AS REQUIRED
TOILET - WATER CLOSET SHALL BE IN COMPLIANCE OF SECTION 411.0 OF CPC AND HAS
MAX EFFECTIVE FLUSH RATE OF 1.28 GAL. PER FLUSH (CPC 411.2). WATER CLOSETS CLR.
TO BE 24” IN FRONT AND 15” FROM ITS CENTER TO ANY SIDE WALL OR OBSTRUCTION.
(CPC 402.5 & CRC R307) – REF. CALGREEN NOTES ON T SHTS. FOR MAX FLOW RATE
FIREPLACE - FACTORY-BUILT DIRECT VENT GAS FIREPLACE W/. SEALED COMBUSTION
(CALGREEN 4.503) - FACTORY-BUILT FIREPLACES, CHIMNEYS AND ALL OF THEIR
COMPONENTS SHALL BE LISTED AND INSTALLED IN ACCORDANCE WITH THEIR LISTING
AND MANUFACTURER'S INSTALLATION INSTRUCTIONS. (CRC R1004.1)
RECESSED MAIN SERVICE PANEL - 400 AMP MAX. (MAINTAIN 36" CLEAR FROM
FACE OF PANEL TO ANY OBSTRUCTION) – GC TO COORDINATE W/. UTILITY COMPANY
FAU - PROVIDE GAS S.O., POWER, AND VENTING AS REQ'D. BY MFG'R. – INSTALL PER
MFGR. INSTRUCTION
ROOF/DECK DRAIN - PER CHAPTER 11 OF CPC - SIZE THE DRAIN AND PIPING PER
TABLE 1103.1 AND 1103.2 OF CPC – ROOF DRAIN SHALL HAVE DOMED STRAINER (CPC
1102.2) – REF. DETAIL 11/AD-1.0
OVERFLOW OR EMERGENCY DRAIN - PER CHAPTER 11 OF CPC - COPPER OR EQ.,
INSTALL PER MFGR. INSTRUC., SLOPED TOWARD IN-WALL DRAIN INLETS – SLOPE AND
SIZE PER TABLE 1103.3 OF CPC – REF. DTL. 11/AD-1.0
CHANNEL DRAIN - CHANNEL DRAIN W/. GRATE IN COMPLIANCE W/. CHAPTER 11 OF
CPC - COPPER OR EQ., INSTALL PER MFGR. INSTRUCTION, SLOPED TOWARD IN-WALL
DRAIN INLETS – SLOPE AND SIZE PER TABLE 1103.3 OF CPC – REF. DETAIL 11/AD-1.0,
ARCH. TO APPV. GRATE COLOR AND TYPE
A/C CONDENSER / HEAT PUMP - TO BE IN COMPLIANCE OF SECTION 307.3 OF CPC
AS SELECTED, VERIFY W/. OWNER - SIZE TBD, SEE T-24 ENERGY REPORT FOR MORE
INFO – PROVIDE POWER AND SOUND DAMPENING PAD AS REQ’D. – INSTALL AND
MAINTAIN REQUIRED CLEARANCES PER MFGR. INSTRUCTION
2x6 STUD WALL
2x8 STUD WALL
STUDS MIN. SPACING PER STRUCT. AND EXT. FINISH MFGR.
INSTRUCTION AND/OR LISTING – SEE EXT. WALL DETAILS AND
STRUCT. DWGS
CONCRETE WALL - 12” REINFORCED CAST IN PLACE CONCRETE WALL TYP. U.N.O.
PER STRUCT., REF. STRCUTC. DWGS. – FOR BASEMENT/RETAINING CONCRETE WALL
PROVIDE WATERPROOFING OR DAMPPROOFING AND DRAINAGE AS REQUIRED PER
SECTION R406.1 & R406.2, REF. SOILS REPORT,WATERPROOFING & DAMPROOFING
NOTES ON SHEET T-1.1 – EXPOSED SURFACES TO HAVE TROWELED SMOOTH FINISH
WITH A LIGHT GRAY COLOR, PROVIDE SAMPLE FOR ARCH. APPROVAL
STRUCTURAL STEEL COLUMN - PER STRUCT., REF. STRUTC. DWGS, - PAINT AND
SEAL AS REQUIRED – ARCH. TO APPV. COLOR FOR EXPOSED STEEL COLUMNS
STRUCTURAL WOOD POST/COLUMN - PER STRUCT., REF. STRUTC. DWGS, - PAINT,
STAIN AND SEAL AS REQUIRED – ARCH. TO APPV. PAINT COLOR FOR EXPOSED WOOD
POST/COLUMN, IF TO BE STAINED PROVIDE STAINED SAMPLE FOR ARCH, APPROVAL
WASHER (W) & DRYER (D) / STACKED (W/D) - AS SELECTED PER I.D., VERIFY W/. I.D.
& OWNER – PROVIDE POWER , GAS, WATER SUPPLY & DRAINAGE AS REQUIRED - THE
CLOTHES DRYERS VENT SHALL BE OF A RIGID METALLIC MATERIAL AND HAVE A
BACKDRAFT DAMPER (CMC 504.4) AND SHALL NOT EXCEED 14-FEET IN OVERALL LENGTH
WITH MAX. OF TWO (2) 90-DEGREE ELBOW, SUBTRACT 2-FEET FOR EACH ADDITIONAL 90-
DEGREE ELBOW. SEE WASHER & DRYER NOTES, REF. T-1.1.
SEE SHEET AD-2.0 FOR THE TYPICAL DEPRESSION OF DOORS AND
WINDOWS, VERIFY ALL THE DEPRESSION W/. MFGR.
VERTICAL STORM DRAIN PIPE IN-WALL ( ) / OVERFLOW ( )- MTL. PIPE PER
CHAPTER 11 OF CPC, SIZE PER TABLE 1103.1 (MIN. 2” DIA. PIPE & TYP. 3” DIA. PIPE) – SEE
CIVIL DWGS. FOR TERMINATION DTLS. ABV. OR BLW. GROUND. VERIFY ALL TERMINATION
POINTS, TYPE AND DETAILS W/. CIVIL PRIOR TO POURING THE CONCRETE SLAB
TANKLESS WATER HEATER - SIZE AND INSTALL PER CHAPTER 5 OF CPC AND MFGR.
INSTRUCTION, VERIFY THE SIZING W/. T-24 ENERGY REPORT – THE WATER HEATER
BURNER AND BURNER-IGNITION DEVICE TO BE AT LEAST 18-INCHES ABOVE THE FLOOR,
IF LOCATED IN A GARAGE AND IN ADJACENT SPACES THAT OPEN TO THE GARAGE. FOR
WATER HEATER IN THE GARAGE OR OTHER AREAS SUBJECT TO MECHANICAL DAMAGE
PROVIDE A PROTECTIVE BARRIER OR ELEVATE THE APPLIANCE TO BE OUT OF THE
NORMAL PATH OF THE VEHICLE. (CPC 507.13)
SCALE: 1/4" = 1'-0"1THIRD LEVEL DIMENSION PLAN
BRANDON ARCHITECTS
DATE
A-3.0
PROJECT CONTACT
JEFF VAN VOORHIS, AIA
PROJECT NAME
PROJECT ADDRESS
908 W. OCEANFRONT
NEWPORT BEACH, CA 92661
OWNER INFORMATION
908 NB PROPERTY MANAGEMENT LLC
3717 EUCLID AVE.
DALLAS, TX
PROJECT STATUS
SECOND CHECK
PLAN CHECK NO.
TBD
REVISIONS
NO.
DATE
5/28/2021 HARVEY RESIDENCEROOF PLAN
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
REVISIONS
These documents are the property of BRANDON
ARCHITECTS INC., and are not to be duplicated,
altered or utilized in any ay by any other party
without the expressed authorization of
BRANDON ARCHITECTS. Any unauthorized
duplication or alteration of these documents by
any party is a violation of BRANDON
ARCHITECTS expressed common law copyright
and other property rights thereto, and is subject
to full civil liabilities and penalties. These plans
are also not to be assigned to any third party
without obtaining written authorization and
expressed permission by BRANDON
ARCHITECTS, who shall then be held harmless
and absolved of any liability regarding any use
of these documents by such third party whether
depicted or implied hereon.A GENERAL NOTES
B KEYNOTES
DIMENSION NOTE:
ALL DIMS. ARE TO FACE OF STUD (F.O.S.) OR FACE OF SHT'G. (F.O.S.) TYP. U.N.O. EAVE DIMS. ARE FROM FACE OF SHT'G. TO FACE OF
FINISH FASCIA
ENLOSED ATTIC AND ENCLOSED RAFTER SPACES VENTING NOTES:
1. ENCLOSED ATTIC AND ENCLOSED RAFTER SPACES SHALL HAVE CROSS VENTILATION BY VENTILATION OPENING PROTECTED
AGAINST THE ENTRANCE OF RAIN OR SNOW UNLESS THEY MEET THE REQUIREMENT OF SECTION R806.5 FOR UNVENTED ATTIC AND
UNVENTED ENCLOSED RAFTER ASSEMBLIES. VENTILATION OPENING SHALL HAVE THE LEAST DIMENSION OF 1/16” MIN. AND 1/4”
MAX OTHERWISE THE OPENING SHALL HAVE THE CORROSION-RESISTANT WIRE CLOTH SCREENING, HARDWARE CLOTH,
PERFORATED VINYL OR SIMILAR MATERIAL WITH OPENINGS HAVE A LEAST DIMENSION OF 1/16” MIN. AND 1/4” MAX. OPENING INROOF FRAMING MEMBERS SHALL BE PER THE REQUIREMENT OF SECTION R802.7. REQUIRED VENTILATION OPENINGS SHALL OPEN
DIRECTLY TO THE OUTSIDE AIR AND SHALL BE PROTECTED TO PREVENT THE ENTRY OF BIRDS, RODENTS, SNAKES AND OTHER
SIMILAR CREATURES. (R806.1)
2. THE MINIMUM NET FREE VENTILATING AREA SHOULD BE 1/150 OF THE AREA OF THE VENTED SPACE, EXCEPT FOR THE PROJECT
LOCATED IN CLIMATE ZONE 14 OR 16 WITH A CLASS I OR II VAPOR RETARDER AT THE WARM-IN-WINTER SIDE OF THE CEILING AND
WHERE MIN. 40% AND MAX 50% OF THE REQUIRED VENTILATION PROVIDED IN THE UPPER PORTION OF THE ATTIC OR RAFTER
SPACE PER SECTION R806.2 THEN THE MINIMUM NET FREE VENTILATING AREA CAN BE 1/300 OF THE VENTED SPACE. (R802.2)
3. PROVIDE 1” SPACE BETWEEN THE INSULATION AND THE ROOF SHEATHING WHERE EAVE OR CORNICE VENTS PROVIDE BLOCKING,
BRIDGING AND INSULATION SHALL NOT BLOCK THE FREE FLOW OF AIR. (R806.3)
4. INSTALL VENTILATOR PER MANUFACTURER INSTRUCTION. INSTALL VENTILATOR IN ROOF PER SECTION R903 AND VENTILATOR IN
WALL ASSEMBLIES PER SECTION R703.1.
5. FOR THE ATTIC WITH VERTICAL HEIGHT GREATER THAN OR EQUAL TO 30” (VERTICAL HEIGHT MEASURED FROM THE TOP OF CEILING
JOIST TO THE BOTTOM OF THE ROOF RAFTERS) WITHIN 30S.F. MIN. PROVIDE THE OPENING WITH ROUGH-FRAMED OPENING OF NOTLESS THAN 22”X30” WHICH SHOULD BE LOCATED IN HALLWAY OR OTHER LOCATION WITH READY ACCESS. IF THE ACCESS LOCATED
IN THE WALL THEN THE WIDTH SHOULD BE 22” AND HEIGHT SHOULD BE 30” MIN. IF LOCATED IN CEILING THEN THE MIN.
UNOBSTRUCTED HEADROOM IN THE ATTIC SHOULD BE 30” FROM THE BOTTOM OF CEILING JOIST AT SOME POINT.
ROOF DRAINAGE:
IF THE PROJECT LOCATED IN THE AREA WITH EXPANSIVE OR COLLAPSIBLE SOILS, WATER RUNOFF FROM ROOFS OF ALL DWELLINGS
SHALL BE DISCHARGED TO THE GROUND SURFACE NOT LESS THAN 5 FEET FROM FOUNDATION WALLS OR TO AN APPROVED DRAINAGE
SYSTEM. (R801.3) - REF.CIVIL DWGS FOR STORM WATER MANAGMENT AND SYSTEM.
WEATHER PROTECTION:
1. ROOF DECKS SHALL BE COVERED WITH APPROVED ROOF COVERINGS SECURED TO THE BUILDING OR STRUCTURE IN ACCORDANCE
WITH THE CHAPTER 9 OF THE CURRENT CRC. ROOF ASSEMBLIES SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH THE
CHAPTER 9 OF CRC AND THE APPROVED MANUFACTURER’S INSTRUCTIONS SUCH THAT THE ROOF ASSEMBLY SHALL SERVE TO
PROTECT THE BUILDING OR STRUCTURE. (R903.1)
2. PROVIDE AND INSTALL FLASHING TO PREVENT ENTRY OF MOISTURE TO WALL AND ROOF ASSEMBLIES THRU THE JOINTS IN
COPINGS, PERMEABLE MATERIAL, AND AT INTERSECTION WITH PARAPET WALLS AND OTHER PENETRATION THRU ROOF. (R903.2)
3. FLASHINGS SHALL BE INSTALLED AT WALL AND ROOF INTERSECTIONS, WHEREVER THERE IS A CHANGE IN ROOF SLOPE OR
DIRECTION AND AROUND ROOF OPENINGS. A FLASHING SHALL BE INSTALLED TO DIVERT THE WATER AWAY FROM WHERE THE EAVE
OF A SLOPED ROOF INTERSECTS A VERTICAL SIDEWALL. WHERE FLASHING IS OF METAL, THE METAL SHALL BE CORROSION
RESISTANT WITH A THICKNESS OF NOT LESS THAN 0.019 INCH (0.5 MM) (NO. 26 GALVANIZED SHEET). (R903.2.1)
4. A CRICKET OR SADDLE SHALL BE INSTALLED ON THE RIDGE SIDE OF ANY CHIMNEY OR PENETRATION MORE THAN 30 INCHES (762
MM) WIDE AS MEASURED PERPENDICULAR TO THE SLOPE. CRICKET OR SADDLE COVERINGS SHALL BE SHEET METAL OR OF THE
SAME MATERIAL AS THE ROOF COVERING. EXCEPT FOR UNIT SKYLIGHTS INSTALLED IN ACCORDANCE WITH HYPERLINK
"HTTPS://CODES.ICCSAFE.ORG/LOOKUP/CRC2019P1_PT03_CH03_SECR308.6" SECTION R308.6 AND FLASHED IN ACCORDANCE WITH
THE MANUFACTURER’S INSTRUCTIONS SHALL BE PERMITTED TO BE INSTALLED WITHOUT A CRICKET OR SADDLE. (R903.2)
5. PARAPET WALLS SHALL BE PROPERLY COPED WITH NONCOMBUSTIBLE, WEATHERPROOF MATERIALS OF A WIDTH NOT LESS THAN
THE THICKNESS OF THE PARAPET WALL. (R903.3)
6. UNLESS ROOFS ARE SLOPED TO DRAIN OVER ROOF EDGES, ROOF DRAINS SHALL BE INSTALLED AT EACH LOW POINT OF THE ROOF.
IF WATER CAN BE ENTRAPPED WITHIN THE ROOF AREA THEN SECONDARY EMERGENCY OVERFLOW ROOF DRAINS OR SCUPPERSSHALL BE PROVIDED PER SECTION R903.4.1. (R903.4)
MISC. NOTES:
1. INSTALL ROOF PER ROOFING MFG'R. SPECS & INSTALLATION GUIDELINE
2. ARCH. TO APPV. SIZE, COLOR & PROFILE OF EAVE & RAKE COMPONENTS. G.C. TO PROVIDE MOCK-UPS.
3. UNVENTED ENCLOSED RAFTER ASSEMBLY: NO INTERIOR CLASS I VAPOR RETARDER SHALL BE INSTALLED ON THE CEILING SIDE
(ATTIC FLOOR) OF THE UNVENTED ATTIC ASSEMBLY OR ON THE CEILING SIDE OF THE UNVENTED ENCLOSED ROOF FRAMING
ASSEMBLY.
4. REF. WOOD OR WOODBASE PRODUCT NOTES ON FLOOR PLANS
3
A-3.0
2
A-3.0
2
A-3.0
3
A-3.0 3
A-3.0
16
AD-1.0
16
AD-1.0
16
AD-1.0
5
A-3.0
5
A-3.0
5
A-3.0
3
A-5.0
3
A-5.0
2
A-5.0
2
A-5.0
1
A-5.1
1
A-5.1
1
A-5.0
1
A-5.0
3
A-5.1
3
A-5.1
2
A-5.1
2
A-5.1
1
A-4.0
2
A-4.0
4
A-4.0
3
A-4.03'-0"S.Y.S.B.3'-0"S.Y.S.B.8'-0"
F.Y.S.B.5'-0"3'-10"8'-1"15'-0 1/4"33'-5 1/8"
44'-9"5'-3 3/4"15'-0"THIRD FLOOR SETBACK
23'-0"
THIRD FLOOR SETBACK 5'-0"THIRD FLOOR SETBACK2'-1"F.O.F.1'-1"1'-1"2'-0"F.O.F.1'-1"2'-0"F.O.F.2'-1"F.O.F.1'-1"6 1/8"
6 1/8"2'-0"F.O.F.2'-0"F.O.F.40.30' HT. CERT. REQ'D.40.30' HT. CERT. REQ'D.40.08' HT. CERT. REQ'D.40.30'HT. CERT. REQ'D.38.38' HT. CERT. REQ'D.38.38' HT. CERT. REQ'D.40.36' HT. CERT. REQ'D.3:123:123:123:123:123:123:123:122% MIN.
2% MIN.
13.01
13.0113.01
13.01
34.97' T.W.
32.69' T.W.
32.69' T.W.
31.97'
31.97'
ROOFING - METAL
ROOFING - METAL
ROOFING - TPO
ROOFING - TPO
ROOFING - METALOPEN TO BLW.
OPEN TO BLW.
OPEN TO BLW.
OPEN TO BLW.
FUTURE SOLAR
PANEL LOC'N
35.34' T.W.
ROOFING PER PLAN & MAT. SCHED. A/A-4.0
ROOF SHT'G PER STRUCT.
DRIP EDGE (TYP.)
2X ROOD RAFTER
(2) SOLID 2X BLK'G. FOR 1-HR. COND.
INTERIOR FINISH, PER PLAN (WHERE OCCURS)
TYVEK OR EQ. BLD'G. WRAP
CDX PLYWD. SHT'G (PER STRUCT.)
EXTERIOR SIDING - REF. ELEV. & MAT.
SCHED.
CONT. 2x10 FASCIA - ARCH. TO APPV. SIZE
PRIOR TO CUTTING ROOF RAFTERS
OVERHANGPER PLAN
EAVE FLASHING W/. DRIP (BY ROOFING MFGR.) TO
MATCH ROOF
CAULK & FLASHING
CONT. 2x10 FASCIA - ARCH. TO APPV. SIZE
PRIOR TO CUTTING ROOF RAFTERS
(2) 2X SOLID BLK'G. FOR 1-HR. COND.
FLASHING AS NEEDED
EXTERIOR FINISH - REF. PLANS & MAT. SCHED.
'TYVEK' OR EQ. BLDG. WRAP
CDX PLYWD. SHT'G. (PER STRUCT'L.)
INTERIOR FINISH, PER PLAN (WHERE OCCURS)
THERMAL BATT INSUL'N.
2x ROOF RAFTER
(PER STRUCT.)
*INTERIOR FINISH
(PER PLANS, AS OCCURS)
AIR-PERMEABLE INSULATION
(PER PLANS & T24), TO BE IN
DIRECT CONTACT WITH THE
UNDER SIDE OF THE
STRUCTURAL ROOF SHEATHING
FOR UNVENTED ASSEMBLY
(1) LAYER TYPE II (NO. 30) ROOF FELT-(2)
LAYERS GAF VERSASHIELD UNDERLAYMENT
15/32" CDX PLYWD. SHT'G. MIN. (REF. STRUCT)
FASTENERS PER MFGR. INSTRUCTIONS
12
SLOPE PER PLAN (2:12 MIN.)
STANDING SEAM METAL (ZINC OR EQUIV.) -
REF. MAT. SCHED. A/A-4.0, CLASS 'A' ASSY.
TYP.6" - 10"6" MIN.
DOUBLE FOLD
3/4" LOCK, ALT. METHOD
CLEATS @ 18" O.C. MAX.
CONT. LOCK STRIP,
SOLDERED
ARCH. TO APPV.
12"-16"1-1/2" HIGHVALLEY DETAIL
*UNVENTED ENCLOSED RAFTER ASSEMBLY NOTE:
NO INTERIOR CLASS I VAPOR RETARDER SHALL BE INSTALLED ON THE
CEILING SIDE (ATTIC FLOOR) OF THE UNVENTED ATTIC ASSEMBLY OR ON THE
CEILING SIDE OF THE UNVENTED ENCLOSED ROOF FRAMING ASSEMBLY.
R-5 SPRAYED AIR-IMPERMEABLE INSULATION
PER TABLE R806.5 @ UNVENTED ASSEMBLIES
NOTE: REF. ROOF MFG'R.
DETAILS AND INSTALLATION
GUIDE LINE FOR MORE INFO
PRODUCT LISTING:
ICC # ESR-2048, CB-150 & SL-1750
2x ROOF RAFTER
(PER STRUCT.)
*INTERIOR FINISH
(PER PLANS, AS OCCURS)
AIR-PERMEABLE INSULATION
(PER PLANS & T24), TO BE IN
DIRECT CONTACT WITH THE
UNDER SIDE OF THE
STRUCTURAL ROOF SHEATHING
FOR UNVENTED ASSEMBLY
(1) LAYER TYPE II (NO. 30) ROOF FELT-(2)
LAYERS GAF VERSASHIELD UNDERLAYMENT
15/32" CDX PLYWD. SHT'G. MIN. (REF. STRUCT)
FASTENERS PER MFGR. INSTRUCTIONS
12
SLOPE PER PLAN (2:12 MIN.)STANDING SEAM METAL (ZINC OR EQUIV.) -
REF. MAT. SCHED. A/A-4.0, CLASS 'A' ASSY.
TYP.6" - 10"6" MIN.
DOUBLE FOLD
3/4" LOCK, ALT. METHOD
CLEATS @ 18" O.C. MAX.
CONT. LOCK STRIP,
SOLDERED
ARCH. TO APPV.
12"-16"1-1/2" HIGHVALLEY DETAIL
PRODUCT LISTING:
ICC # ESR-2048, CB-150 & SL-1750
*UNVENTED ENCLOSED RAFTER ASSEMBLY NOTE:
NO INTERIOR CLASS I VAPOR RETARDER SHALL BE INSTALLED ON THE
CEILING SIDE (ATTIC FLOOR) OF THE UNVENTED ATTIC ASSEMBLY OR ON THE
CEILING SIDE OF THE UNVENTED ENCLOSED ROOF FRAMING ASSEMBLY.
R-5 RIGID AIR-IMPERMEABLE INSULATION PER
TABLE R806.5 @ UNVENTED ASSEMBLIES
NOTE: REF. ROOF MFG'R.
DETAILS AND INSTALLATION
GUIDE LINE FOR MORE INFO
2x ROOF RAFTER
(PER STRUCT.)
*INTERIOR FINISH
(PER PLANS, AS OCCURS)
AIR-PERMEABLE INSULATION
(PER PLANS & T24), TO BE IN
DIRECT CONTACT WITH THE
UNDER SIDE OF THE
STRUCTURAL ROOF SHEATHING
FOR UNVENTED ASSEMBLY
(1) LAYER TYPE II (NO. 30) ROOF FELT-(2)
LAYERS GAF VERSASHIELD UNDERLAYMENT
15/32" CDX PLYWD. SHT'G. MIN. (REF. STRUCT)
FASTENERS PER MFGR. INSTRUCTIONS
12
SLOPE PER PLAN (1/2:12 MIN.)
STANDING SEAM METAL (ZINC OR EQUIV.) W/.
APPLIED LAP SEALANT (#2 OF R905.10.2),
APPLY LAP SEALANT PER MFG'R. -REF. MAT.
SCHED. A/A-4.0, CLASS 'A' ASSY.
TYP.6" - 10"6" MIN.
DOUBLE FOLD
3/4" LOCK, ALT. METHOD
CLEATS @ 18" O.C. MAX.
CONT. LOCK STRIP,
SOLDERED
ARCH. TO APPV.
12"-16"1-1/2" HIGHVALLEY DETAIL
*UNVENTED ENCLOSED RAFTER ASSEMBLY NOTE:
NO INTERIOR CLASS I VAPOR RETARDER SHALL BE INSTALLED ON THE
CEILING SIDE (ATTIC FLOOR) OF THE UNVENTED ATTIC ASSEMBLY OR ON THE
CEILING SIDE OF THE UNVENTED ENCLOSED ROOF FRAMING ASSEMBLY.
R-5 SPRAYED AIR-IMPERMEABLE INSULATION
PER TABLE R806.5 @ UNVENTED ASSEMBLIES
NOTE: REF. ROOF MFG'R.
DETAILS AND INSTALLATION
GUIDELINE FOR MORE INFO
PRODUCT LISTING:
ICC # ESR-2048, CB-150 & SL-1750
2x ROOF RAFTER
(PER STRUCT.)
*INTERIOR FINISH
(PER PLANS, AS OCCURS)
AIR-PERMEABLE INSULATION
(PER PLANS & T24), TO BE IN
DIRECT CONTACT WITH THE
UNDER SIDE OF THE
STRUCTURAL ROOF SHEATHING
FOR UNVENTED ASSEMBLY
(1) LAYER TYPE II (NO. 30) ROOF FELT-(2)
LAYERS GAF VERSASHIELD UNDERLAYMENT
15/32" CDX PLYWD. SHT'G. MIN. (REF. STRUCT)
FASTENERS PER MFGR. INSTRUCTIONS
12
SLOPE PER PLAN (1/2:12 MIN.)STANDING SEAM METAL (ZINC OR EQUIV.)
W/. APPLIED LAP SEALANT (#2 OF R905.10.2),
APPLY LAP SEALANT PER MFG'R. -REF. MAT.
SCHED. A/A-4.0, CLASS 'A' ASSY.
TYP.6" - 10"6" MIN.
DOUBLE FOLD
3/4" LOCK, ALT. METHOD
CLEATS @ 18" O.C. MAX.
CONT. LOCK STRIP,
SOLDERED
ARCH. TO APPV.
12"-16"1-1/2" HIGHVALLEY DETAIL
*UNVENTED ENCLOSED RAFTER ASSEMBLY NOTE:
NO INTERIOR CLASS I VAPOR RETARDER SHALL BE INSTALLED ON THE
CEILING SIDE (ATTIC FLOOR) OF THE UNVENTED ATTIC ASSEMBLY OR ON THE
CEILING SIDE OF THE UNVENTED ENCLOSED ROOF FRAMING ASSEMBLY.
R-5 RIGID AIR-IMPERMEABLE INSULATION PER
TABLE R806.5 @ UNVENTED ASSEMBLIES
NOTE: REF. ROOF MFG'R.
DETAILS AND INSTALLATION
GUIDE LINE FOR MORE INFO
PRODUCT LISTING:
ICC # ESR-2048, CB-150 & SL-1750
2x ROOF RAFTER
(PER STRUCT.)
*INTERIOR FINISH
(PER PLANS, AS OCCURS)
AIR-PERMEABLE INSULATION
(PER PLANS & T24), TO BE IN
DIRECT CONTACT WITH THE
UNDER SIDE OF THE
STRUCTURAL ROOF SHEATHING
FOR UNVENTED ASSEMBLY
(1) LAYER TYPE II (NO. 30) ROOF FELT-(2)
LAYERS GAF VERSASHIELD UNDERLAYMENT
15/32" CDX PLYWD. SHT'G. MIN. (REF. STRUCT)
FASTENERS PER MFGR. INSTRUCTIONS
12
SLOPE PER PLAN (1/4:12 MIN.)
STANDING SEAM METAL (ZINC OR EQUIV.)
W/. SOLDERED SEAM & APPLIED LAP
SEALANT (#3 OF R905.10.2), APPLY LAP
SEALANT PER MFG'R. -REF. MAT. SCHED.
A/A-4.0, CLASS 'A' ASSY.
TYP.6" - 10"6" MIN.
DOUBLE FOLD
3/4" LOCK, ALT. METHOD
CLEATS @ 18" O.C. MAX.
CONT. LOCK STRIP,
SOLDERED
ARCH. TO APPV.
12"-16"1-1/2" HIGHVALLEY DETAIL
*UNVENTED ENCLOSED RAFTER ASSEMBLY NOTE:
NO INTERIOR CLASS I VAPOR RETARDER SHALL BE INSTALLED ON THE
CEILING SIDE (ATTIC FLOOR) OF THE UNVENTED ATTIC ASSEMBLY OR ON THE
CEILING SIDE OF THE UNVENTED ENCLOSED ROOF FRAMING ASSEMBLY.
R-5 SPRAYED AIR-IMPERMEABLE INSULATION
PER TABLE R806.5 @ UNVENTED ASSEMBLIES
NOTE: REF. ROOF MFG'R.
DETAILS AND INSTALLATION
GUIDELINE FOR MORE INFO
PRODUCT LISTING:
ICC # ESR-2048, CB-150 & SL-1750
2x ROOF RAFTER
(PER STRUCT.)
*INTERIOR FINISH
(PER PLANS, AS OCCURS)
AIR-PERMEABLE INSULATION
(PER PLANS & T24), TO BE IN
DIRECT CONTACT WITH THE
UNDER SIDE OF THE
STRUCTURAL ROOF SHEATHING
FOR UNVENTED ASSEMBLY
(1) LAYER TYPE II (NO. 30) ROOF FELT-(2)
LAYERS GAF VERSASHIELD UNDERLAYMENT
15/32" CDX PLYWD. SHT'G. MIN. (REF. STRUCT)
FASTENERS PER MFGR. INSTRUCTIONS
12
SLOPE PER PLAN (1/4:12 MIN.)STANDING SEAM METAL (ZINC OR EQUIV.)
W/. SOLDERED SEAM & APPLIED LAP
SEALANT (#3 OF R905.10.2), APPLY LAP
SEALANT PER MFG'R. -REF. MAT. SCHED.
A/A-4.0, CLASS 'A' ASSY.
TYP.6" - 10"6" MIN.
DOUBLE FOLD
3/4" LOCK, ALT. METHOD
CLEATS @ 18" O.C. MAX.
CONT. LOCK STRIP,
SOLDERED
ARCH. TO APPV.
12"-16"1-1/2" HIGHVALLEY DETAIL
*UNVENTED ENCLOSED RAFTER ASSEMBLY NOTE:
NO INTERIOR CLASS I VAPOR RETARDER SHALL BE INSTALLED ON THE
CEILING SIDE (ATTIC FLOOR) OF THE UNVENTED ATTIC ASSEMBLY OR ON THE
CEILING SIDE OF THE UNVENTED ENCLOSED ROOF FRAMING ASSEMBLY.
R-5 RIGID AIR-IMPERMEABLE INSULATION PER
TABLE R806.5 @ UNVENTED ASSEMBLIES
NOTE: REF. ROOF MFG'R.
DETAILS AND INSTALLATION
GUIDE LINE FOR MORE INFO
PRODUCT LISTING:
ICC # ESR-2048, CB-150 & SL-1750
ROOF FRAMING
PER STRUCT.
COUNTER FLASHING PER ROOF MFG'R.
FACTORY STANDING SEAM OR
TURN UP PANEL
EXT. FINISH PER PLANS, REF. MAT.
SCHED. A/A-4.0
AIR-PERMEABLE INSULATION (PER
PLANS & T24), TO BE IN DIRECT
CONTACT WITH THE UNDER SIDE OF
THE STRUCTURAL ROOF SHEATHING
FOR UNVENTED ASSEMBLY
MIN. 30# ROOF FELT-(2) LAYERS GAF
VERSASHIELD UNDERLAYMENT
UNVENTED ENCLOSED RAFTER ASSEMBLY NOTE:
NO INTERIOR CLASS I VAPOR RETARDER SHALL BE INSTALLED ON THE
CEILING SIDE (ATTIC FLOOR) OF THE UNVENTED ATTIC ASSEMBLY OR ON THE
CEILING SIDE OF THE UNVENTED ENCLOSED ROOF FRAMING ASSEMBLY.
R-5 SPRAYED AIR-IMPERMEABLE
INSULATION PER TABLE R806.5 @
UNVENTED ASSEMBLIES
CAULK AND SEAL AS REQ'D.
RAKE SIDEWALL FLASHING PER ROOF
MFG'R.
1/8" RIVET 12" O.C. AND BUTYL TAPE
TAPE FLASHING OVER COUNTER FLASHING
MOISTURE BARRIER ('TYVEK' OR EQ.
WEATHER PROOF COVERING (MIN. 2 LAYERS
GRADE D PAPER)
NOTE:
REF. ROOF MFG'R. DETAILS AND INSTALLATION GUIDE LINE FOR MORE INFO
RAKE SUPPORT TRIM
WALL FRAMING PER STRUCT.ROOF FRAMING
PER STRUCT.
COUNTER FLASHING PER ROOF MFG'R.
EXT. FINISH PER PLANS, REF. MAT.
SCHED. A/A-4.0
AIR-PERMEABLE INSULATION (PER
PLANS & T24), TO BE IN DIRECT
CONTACT WITH THE UNDER SIDE OF
THE STRUCTURAL ROOF SHEATHING
FOR UNVENTED ASSEMBLY
MIN. 30# ROOF FELT-(2) LAYERS GAF
VERSASHIELD UNDERLAYMENT
UNVENTED ENCLOSED RAFTER ASSEMBLY NOTE:
NO INTERIOR CLASS I VAPOR RETARDER SHALL BE INSTALLED ON THE
CEILING SIDE (ATTIC FLOOR) OF THE UNVENTED ATTIC ASSEMBLY OR ON THE
CEILING SIDE OF THE UNVENTED ENCLOSED ROOF FRAMING ASSEMBLY.
R-5 SPRAYED AIR-IMPERMEABLE
INSULATION PER TABLE R806.5 @
UNVENTED ASSEMBLIES
CAULK AND SEAL AS REQ'D.
HEAD WALL FLASHING PER
ROOF MFG'R.
1/8" RIVET 12" O.C.
TAPE FLASHING OVER COUNTER FLASHING
MOISTURE BARRIER ('TYVEK' OR EQ.
WEATHER PROOF COVERING (MIN. 2 LAYERS
GRADE D PAPER)
NOTE:
REF. ROOF MFG'R. DETAILS AND INSTALLATION GUIDE LINE FOR MORE INFO
ZEE CLOSURE, SET IN DOUBLE BEAD
TAPE AND UP VERTICAL LEG
SHEATHING PER STRUCT.
STANDING SEAM METAL (ZINC OR
EQUIV.) -REF. MAT. SCHED. A/A-4.0,
CLASS 'A' ASSY.WALL FRAMING PER STRUCT.*UNVENTED ENCLOSED RAFTER
ASSEMBLY NOTE:
NO INTERIOR CLASS I VAPOR
RETARDER SHALL BE INSTALLED
ON THE CEILING SIDE (ATTIC
FLOOR) OF THE UNVENTED
ATTIC ASSEMBLY OR ON THE
CEILING SIDE OF THE UNVENTED
ENCLOSED ROOF FRAMING
ASSEMBLY.
R-5 SPRAYED AIR-IMPERMEABLE INSULATION PER TABLE R806.5
R-5 RIGID AIR-IMPERMEABLE INSULATION PER TABLE R806.5
CUSTOM BUILT KYNAR PAINTED ALUM./STEEL
GUTTER W/. DRIP EDGE TO MATCH METAL
ROOFING - VERIFY W/. ROOF MFGR. SPECS AND
WARRANTY
METAL DEBRIS & LEAF GUARD TO MATCH THE
GUTTER FINISH
FENESTRATION PER PLANS, SHGC AND
U-VALUE PER T-24, REF. T-24 SHEETS1/4"1/2"
AIR-PERMEABLE INSULATION (PER PLANS & T24)
NUSKU TERRATEK (ENGINEERED WESTERN RED CEDAR) 1X6 T&G FINE
LINE, REF. MAT. SCHED. A/A-4.0, INSTALL PER MFGR. GUIDELINE
6X BLOCKING PER STRUCT.
BEAM AS OCCUR PER STRUCT.
2X10 FASCIA
TAPE FLASHING
BLD'G. WRAP - 'TYVEK' OR EQUIV.
ACM PANEL, INSTALL PER MFG'R. SPECS AND
GUIDELINES, ARCH. TO APPV. COLOR & REVEAL
STANDING SEAM METAL ROOFING W/. LAPPED, SEALED & SOLDERED SEAM PER
R905.10.2
2% MIN. (1/4:12)
15/32" CDX PLYWD. SHT'G. MIN. (REF. STRUCT)
(1) LAYER TYPE II (NO. 30) ROOF FELT-(2) LAYERS GAF VERSASHIELD UNDERLAYMENT
NOTCH PANEL 1" & FORM AROUND CLEAT PER
ROOF MFG'R.
METAL DRIP EDGE TO MATCH ROOFING
CAULK, SEAL & SOLDER AS REQUIERD
MIN.
9"
CAULK & SEAL AS REQUIERD
CAULK & SEAL AS REQ'D.
NOTE:INSTALL ROOF &
SEALANTS AND SOLDER
SEAMS PER ROOFING
MFG'R. INSTALLATION
INSTRUCTION AND
SECTION R905.10.2.INTERIOREXTERIOR
*UNVENTED ENCLOSED RAFTER
ASSEMBLY NOTE:
NO INTERIOR CLASS I VAPOR
RETARDER SHALL BE INSTALLED
ON THE CEILING SIDE (ATTIC
FLOOR) OF THE UNVENTED
ATTIC ASSEMBLY OR ON THE
CEILING SIDE OF THE UNVENTED
ENCLOSED ROOF FRAMING
ASSEMBLY.
R-5 SPRAYED AIR-IMPERMEABLE INSULATION PER TABLE R806.5
R-5 RIGID AIR-IMPERMEABLE INSULATION PER TABLE R806.5
CUSTOM BUILT KYNAR PAINTED ALUM./STEEL
GUTTER W/. DRIP EDGE TO MATCH METAL
ROOFING - VERIFY W/. ROOF MFGR. SPECS AND
WARRANTY
METAL DEBRIS & LEAF GUARD TO MATCH THE
GUTTER FINISH
1/2"
AIR-PERMEABLE INSULATION (PER PLANS & T24)
ACM PANEL, INSTALL PER MFG'R. SPECS AND GUIDELINES, ARCH. TO
APPV. COLOR & REVEAL
6X BLOCKING PER STRUCT.
BEAM AS OCCUR PER STRUCT.
2X12 FASCIA
TAPE FLASHING
BLD'G. WRAP - 'TYVEK' OR EQUIV.
ACM PANEL, INSTALL PER MFG'R. SPECS AND
GUIDELINES, ARCH. TO APPV. COLOR & REVEAL
STANDING SEAM METAL ROOFING W/. LAPPED, SEALED & SOLDERED SEAM PER
R905.10.2
2% MIN. (1/4:12)
15/32" CDX PLYWD. SHT'G. MIN. (REF. STRUCT)
(1) LAYER TYPE II (NO. 30) ROOF FELT-(2) LAYERS GAF VERSASHIELD UNDERLAYMENT
NOTCH PANEL 1" & FORM AROUND CLEAT PER
ROOF MFG'R.
METAL DRIP EDGE TO MATCH ROOFING
CAULK, SEAL & SOLDER AS REQUIERD
MIN.
9"
CAULK & SEAL AS REQUIERD
CAULK & SEAL AS REQ'D.
NOTE:INSTALL ROOF &
SEALANTS AND SOLDER
SEAMS PER ROOFING
MFG'R. INSTALLATION
INSTRUCTION AND
SECTION R905.10.2.2" MAX1 1/2"EXTERIOR
EXTERIOR
*UNVENTED ENCLOSED RAFTER
ASSEMBLY NOTE:
NO INTERIOR CLASS I VAPOR
RETARDER SHALL BE INSTALLED
ON THE CEILING SIDE (ATTIC
FLOOR) OF THE UNVENTED
ATTIC ASSEMBLY OR ON THE
CEILING SIDE OF THE UNVENTED
ENCLOSED ROOF FRAMING
ASSEMBLY.
R-5 SPRAYED AIR-IMPERMEABLE INSULATION PER TABLE R806.5
CUSTOM BUILT KYNAR PAINTED ALUM./STEEL
GUTTER W/. DRIP EDGE TO MATCH METAL
ROOFING - VERIFY W/. ROOF MFGR. SPECS AND
WARRANTY
METAL DEBRIS & LEAF GUARD TO MATCH THE
GUTTER FINISH
AIR-PERMEABLE INSULATION (PER PLANS & T24)
6X BLOCKING PER STRUCT.
ROOF RAFTER AS OCCUR PER STRUCT.
6X BLOCKING, CONNEC. PER STRUCT
TAPE FLASHING
BLD'G. WRAP - 'TYVEK' OR EQUIV.
STUCCO FINISH PER PLAN, REF. 5/AD-1 & A/A-4.0
STANDING SEAM METAL ROOFING W/. LAPPED, SEALED & SOLDERED SEAM PER
R905.10.2
2% MIN. (1/4:12)
15/32" CDX PLYWD. SHT'G. MIN. (REF. STRUCT)
(1) LAYER TYPE II (NO. 30) ROOF FELT-(2) LAYERS GAF VERSASHIELD UNDERLAYMENT
NOTCH PANEL 1" & FORM AROUND CLEAT PER
ROOF MFG'R.
METAL DRIP EDGE TO MATCH ROOFING
CAULK, SEAL & SOLDER AS REQUIERD
MIN.
9"
CAULK & SEAL AS REQ'D.
NOTE:INSTALL ROOF &
SEALANTS AND SOLDER
SEAMS PER ROOFING
MFG'R. INSTALLATION
INSTRUCTION AND
SECTION R905.10.2.2" MAX1 5/8"INTERIOR FINISH PER PLAN *
SHEATHING PER STRUCT.
INTERIOR
EXTERIOR
3X6 CAP PLATE, CONNEC. PER STRUCT
*UNVENTED ENCLOSED RAFTER
ASSEMBLY NOTE:
NO INTERIOR CLASS I VAPOR
RETARDER SHALL BE INSTALLED
ON THE CEILING SIDE (ATTIC
FLOOR) OF THE UNVENTED
ATTIC ASSEMBLY OR ON THE
CEILING SIDE OF THE UNVENTED
ENCLOSED ROOF FRAMING
ASSEMBLY.
R-5 SPRAYED AIR-IMPERMEABLE INSULATION PER TABLE R806.5
AIR-PERMEABLE INSULATION (PER PLANS & T24)
6X BLOCKING PER STRUCT.
ROOF RAFTER AS OCCUR PER STRUCT.
RIM JOIST/BEAM PER STRUCT.
STUCCO FINISH PER PLAN, REF. 5/AD-1 & A/A-4.0
STANDING SEAM METAL ROOFING W/. LAPPED, SEALED & SOLDERED SEAM PER
R905.10.2
2% MIN. (1/4:12)
15/32" CDX PLYWD. SHT'G. MIN. (REF. STRUCT)
(1) LAYER TYPE II (NO. 30) ROOF FELT-(2) LAYERS GAF VERSASHIELD UNDERLAYMENT
EDGE CRICKET TO MATCH ROOFING
MATERIAL, 2% MIN. SLOPE,
CURB FLASHING TO MATCH ROOFING
CAULK, SEAL & SOLDER AS REQUIERD - CAULKING UP INSIDE VERTICAL MALE LEG
PRIOR TO INSTALLING FEMALE LEG OF NEXT PANEL PER CBM INSTRUCTION
NOTE:INSTALL ROOF &
SEALANTS AND SOLDER
SEAMS PER ROOFING
MFG'R. INSTALLATION
INSTRUCTION AND
SECTION R905.10.2.
INTERIOR FINISH PER PLAN *
SHEATHING PER STRUCT.
INTERIOR
EXTERIOR
EDGE CRICKET TO MATCH ROOFING
MATERIAL, 2% MIN. SLOPE,
COUNTER FLASHING PER ROOF MFG'R.
TAPE FLASHING PER ROOF MFG'R.VARIESPER PLANFIELD VERIFY W/. MFG'R.
12" MIN.VARIESCAULK, SEAL & SOLDER AS REQUIERD
2% MIN.
MOISTURE BARRIER ('TYVEK' OR EQ.
WEATHER PROOF COVERING (MIN. 2 LAYERS
GRADE D PAPER)
*UNVENTED ENCLOSED RAFTER
ASSEMBLY NOTE:
NO INTERIOR CLASS I VAPOR
RETARDER SHALL BE INSTALLED
ON THE CEILING SIDE (ATTIC
FLOOR) OF THE UNVENTED
ATTIC ASSEMBLY OR ON THE
CEILING SIDE OF THE UNVENTED
ENCLOSED ROOF FRAMING
ASSEMBLY.
R-5 SPRAYED AIR-IMPERMEABLE INSULATION PER TABLE R806.5
AIR-PERMEABLE INSULATION (PER PLANS & T24)
6X BLOCKING PER STRUCT.
ROOF RAFTER AS OCCUR PER STRUCT.
RIM JOIST/BEAM PER STRUCT.
STONE VENEER PER PLAN, REF. 8/AD-1 & A/A-4.0
STANDING SEAM METAL ROOFING W/. LAPPED, SEALED & SOLDERED SEAM PER
R905.10.2
2% MIN. (1/4:12)
15/32" CDX PLYWD. SHT'G. MIN. (REF. STRUCT)
(1) LAYER TYPE II (NO. 30) ROOF FELT-(2) LAYERS GAF VERSASHIELD UNDERLAYMENT
EDGE CRICKET TO MATCH ROOFING
MATERIAL, 2% MIN. SLOPE,
CURB FLASHING TO MATCH ROOFING
CAULK, SEAL & SOLDER AS REQUIERD - CAULKING UP INSIDE VERTICAL MALE LEG
PRIOR TO INSTALLING FEMALE LEG OF NEXT PANEL PER CBM INSTRUCTION
NOTE:INSTALL ROOF &
SEALANTS AND SOLDER
SEAMS PER ROOFING
MFG'R. INSTALLATION
INSTRUCTION AND
SECTION R905.10.2.
INTERIOR FINISH PER PLAN *
SHEATHING PER STRUCT.
INTERIOR
EXTERIOR
EDGE CRICKET TO MATCH ROOFING
MATERIAL, 2% MIN. SLOPE,
TAPE FLASHING PER ROOF MFG'R.
FIELD VERIFY W/. MFG'R.
12" MIN.
CAULK, SEAL & SOLDER AS REQUIERD
METAL CAP, KYNAR PAINTED, ARCH. TO
APPV. COLOR - TO BE COMPATIBLE W/.
ROOFING - CAP TO SLOPE 2% MIN.
METAL DRIP EDGE TO MATCH ROOFING
MOISTURE BARRIER ('TYVEK' OR EQ.
WEATHER PROOF COVERING (MIN. 2 LAYERS
GRADE D PAPER)
*UNVENTED ENCLOSED RAFTER
ASSEMBLY NOTE:
NO INTERIOR CLASS I VAPOR
RETARDER SHALL BE INSTALLED
ON THE CEILING SIDE (ATTIC
FLOOR) OF THE UNVENTED
ATTIC ASSEMBLY OR ON THE
CEILING SIDE OF THE UNVENTED
ENCLOSED ROOF FRAMING
ASSEMBLY.
R-5 SPRAYED AIR-IMPERMEABLE INSULATION PER TABLE R806.5
AIR-PERMEABLE INSULATION (PER PLANS & T24)
6X BLOCKING PER STRUCT.
ROOF RAFTER AS OCCUR PER STRUCT.
RIM JOIST/BEAM PER STRUCT.
STUCCO FINISH PER PLAN, REF. 5/AD-1 & A/A-4.0
STANDING SEAM METAL ROOFING W/. LAPPED, SEALED & SOLDERED SEAM PER
R905.10.2
15/32" CDX PLYWD. SHT'G. MIN. (REF. STRUCT)
(1) LAYER TYPE II (NO. 30) ROOF FELT-(2) LAYERS GAF VERSASHIELD UNDERLAYMENT
CAULK, SEAL & SOLDER AS REQUIERD -
CAULKING UP INSIDE VERTICAL MALE LEG
PRIOR TO INSTALLING FEMALE LEG OF NEXT
PANEL PER CBM INSTRUCTION
NOTE:INSTALL ROOF &
SEALANTS AND SOLDER
SEAMS PER ROOFING
MFG'R. INSTALLATION
INSTRUCTION AND
SECTION R905.10.2.
INTERIOR FINISH PER PLAN *
SHEATHING PER STRUCT.
INTERIOR
EXTERIOR
COUNTER FLASHING PER ROOF MFG'R.
TAPE FLASHING PER ROOF MFG'R.VARIESPER PLANCAULK, SEAL & SOLDER AS REQUIERD
2% MIN.
RAKE SIDEWALL FLASHING PER ROOF MFG'R.
1/8" RIVET 12" O.C. AND BUTYL TAPE
MOISTURE BARRIER ('TYVEK' OR EQ.
WEATHER PROOF COVERING (MIN. 2 LAYERS
GRADE D PAPER)
RAKE SUPPORT TRIM
*UNVENTED ENCLOSED RAFTER
ASSEMBLY NOTE:
NO INTERIOR CLASS I VAPOR
RETARDER SHALL BE INSTALLED
ON THE CEILING SIDE (ATTIC
FLOOR) OF THE UNVENTED
ATTIC ASSEMBLY OR ON THE
CEILING SIDE OF THE UNVENTED
ENCLOSED ROOF FRAMING
ASSEMBLY.
R-5 SPRAYED AIR-IMPERMEABLE INSULATION PER TABLE R806.5
R-5 RIGID AIR-IMPERMEABLE INSULATION PER
TABLE R806.5
CUSTOM BUILT KYNAR PAINTED ALUM./STEEL
GUTTER W/. DRIP EDGE TO MATCH METAL
ROOFING - VERIFY W/. ROOF MFGR. SPECS AND
WARRANTY
METAL DEBRIS & LEAF GUARD TO MATCH THE
GUTTER FINISH
AIR-PERMEABLE INSULATION (PER PLANS & T24)
3X12 FASCIA
BLD'G. WRAP - 'TYVEK' OR EQUIV.
STANDING SEAM METAL ROOFING W/. LAPPED, SEALED & SOLDERED SEAM PER
R905.10.2
2% MIN. (1/4:12)
15/32" CDX PLYWD. SHT'G. MIN. (REF. STRUCT)
(1) LAYER TYPE II (NO. 30) ROOF FELT-(2) LAYERS GAF VERSASHIELD UNDERLAYMENT
NOTCH PANEL 1" & FORM AROUND CLEAT PER
ROOF MFG'R.
METAL DRIP EDGE TO MATCH ROOFING
CAULK, SEAL & SOLDER AS REQUIERD
CAULK & SEAL AS REQUIERD
NOTE:INSTALL ROOF &
SEALANTS AND SOLDER
SEAMS PER ROOFING
MFG'R. INSTALLATION
INSTRUCTION AND
SECTION R905.10.2.
EXTERIOR
NUSKU TERRATEK (ENGINEERED WESTERN RED
CEDAR) 1X6 T&G FINE LINE, REF. MAT. SCHED.
A/A-4.0, INSTALL PER MFGR. GUIDELINE
1/2"
ACM FASCIA WRAP, INSTALL PER MFG'R. SPECS
AND GUIDELINES, ARCH. TO APPV. COLOR & REVEAL
BLOCKING W/. 1/4" GAP PER STRUCT.
EXTERIOR FINISH PER PLAN
INTERIOR
TAPE FLASHINGROOF RAFTER PER STRUCT.
*UNVENTED ENCLOSED RAFTER
ASSEMBLY NOTE:
NO INTERIOR CLASS I VAPOR
RETARDER SHALL BE INSTALLED
ON THE CEILING SIDE (ATTIC
FLOOR) OF THE UNVENTED
ATTIC ASSEMBLY OR ON THE
CEILING SIDE OF THE UNVENTED
ENCLOSED ROOF FRAMING
ASSEMBLY.
R-5 SPRAYED AIR-IMPERMEABLE INSULATION PER TABLE R806.5
R-5 RIGID AIR-IMPERMEABLE INSULATION PER
TABLE R806.5
AIR-PERMEABLE INSULATION (PER PLANS & T24)
3X12 FASCIA
BLD'G. WRAP - 'TYVEK' OR EQUIV.
STANDING SEAM METAL ROOFING W/. LAPPED, SEALED & SOLDERED SEAM PER
R905.10.2
2% MIN. (1/4:12)
15/32" CDX PLYWD. SHT'G. MIN. (REF. STRUCT)
(1) LAYER TYPE II (NO. 30) ROOF FELT-(2) LAYERS GAF VERSASHIELD UNDERLAYMENT
Z CLOSURE PER ROOFING MFG'R.
CAULK, SEAL & SOLDER AS REQUIERD
CAULK & SEAL AS REQUIERD
NOTE:INSTALL ROOF &
SEALANTS AND SOLDER
SEAMS PER ROOFING
MFG'R. INSTALLATION
INSTRUCTION AND
SECTION R905.10.2.
EXTERIOR
NUSKU TERRATEK (ENGINEERED WESTERN RED
CEDAR) 1X6 T&G FINE LINE, REF. MAT. SCHED.
A/A-4.0, INSTALL PER MFGR. GUIDELINE
ACM FASCIA WRAP, INSTALL PER MFG'R. SPECS
AND GUIDELINES, ARCH. TO APPV. COLOR & REVEAL
EXTERIOR FINISH PER PLANINTERIOR1/2"
CAULK, SEAL & SOLDER AS REQUIERD
PEAK FLASHING W/. DRIP EDGE
TAPE FLASHING
ROOF RAFTER PER STRUCT.
*UNVENTED ENCLOSED RAFTER
ASSEMBLY NOTE:
NO INTERIOR CLASS I VAPOR
RETARDER SHALL BE INSTALLED
ON THE CEILING SIDE (ATTIC
FLOOR) OF THE UNVENTED
ATTIC ASSEMBLY OR ON THE
CEILING SIDE OF THE UNVENTED
ENCLOSED ROOF FRAMING
ASSEMBLY.
1-1/2" THICK MIN. R-5 RIGID AIR-IMPERMEABLE INSULATION PER TABLE R806.5
R-5 RIGID AIR-IMPERMEABLE INSULATION PER
TABLE R806.5
AIR-PERMEABLE INSULATION (PER PLANS & T24)
3X10 FASCIA
BLD'G. WRAP - 'TYVEK' OR EQUIV.
STANDING SEAM METAL ROOFING W/. LAPPED, SEALED & SOLDERED SEAM PER
R905.10.2
2% MIN. (1/4:12)
15/32" CDX PLYWD. SHT'G. MIN. (REF. STRUCT)
(1) LAYER TYPE II (NO. 30) ROOF FELT-(2) LAYERS GAF VERSASHIELD UNDERLAYMENT
Z CLOSURE PER ROOFING MFG'R.
CAULK, SEAL & SOLDER AS REQUIERD
CAULK & SEAL AS REQUIERD
NOTE:INSTALL ROOF &
SEALANTS AND SOLDER
SEAMS PER ROOFING
MFG'R. INSTALLATION
INSTRUCTION AND
SECTION R905.10.2.
EXTERIOR
NUSKU TERRATEK (ENGINEERED WESTERN RED
CEDAR) 1X6 T&G FINE LINE, REF. MAT. SCHED.
A/A-4.0, INSTALL PER MFGR. GUIDELINE
ACM FASCIA WRAP, INSTALL PER MFG'R. SPECS
AND GUIDELINES, ARCH. TO APPV. COLOR & REVEAL
1/2"
CAULK, SEAL & SOLDER AS REQUIERD
PEAK FLASHING W/. DRIP EDGE
TAPE FLASHING
ROOF RAFTER PER STRUCT.
STRUCTURAL BEAM/OUTLOOKER, SIZE PER
STRUCT. - PAINT/STAIN & SEAL AS REQUIRED
ARCH TO APPV. CUT PROFILE & COLOR11 1/4"6 3/8"1' - 11 1/4"3 1/2"
*UNVENTED ENCLOSED RAFTER
ASSEMBLY NOTE:
NO INTERIOR CLASS I VAPOR
RETARDER SHALL BE INSTALLED
ON THE CEILING SIDE (ATTIC
FLOOR) OF THE UNVENTED
ATTIC ASSEMBLY OR ON THE
CEILING SIDE OF THE UNVENTED
ENCLOSED ROOF FRAMING
ASSEMBLY.
R-5 SPRAYED AIR-IMPERMEABLE INSULATION PER TABLE R806.5
R-5 RIGID AIR-IMPERMEABLE INSULATION PER
TABLE R806.5
AIR-PERMEABLE INSULATION (PER PLANS & T24)
3X12 FASCIA
BLD'G. WRAP - 'TYVEK' OR EQUIV.
STANDING SEAM METAL ROOFING W/. LAPPED, SEALED & SOLDERED SEAM PER
R905.10.2
15/32" CDX PLYWD. SHT'G. MIN. (REF. STRUCT)
(1) LAYER TYPE II (NO. 30) ROOF FELT-(2) LAYERS GAF VERSASHIELD UNDERLAYMENT
RAKE FLASHING W/. DRIP EDGE PER
ROOFING MFG'R.
CAULK, SEAL & SOLDER AS REQUIERD
CAULK & SEAL AS REQUIERD
NOTE:INSTALL ROOF &
SEALANTS AND SOLDER
SEAMS PER ROOFING
MFG'R. INSTALLATION
INSTRUCTION AND
SECTION R905.10.2.
EXTERIOR
NUSKU TERRATEK (ENGINEERED WESTERN RED
CEDAR) 1X6 T&G FINE LINE, REF. MAT. SCHED.
A/A-4.0, INSTALL PER MFGR. GUIDELINE
ACM FASCIA WRAP, INSTALL PER MFG'R. SPECS
AND GUIDELINES, ARCH. TO APPV. COLOR & REVEAL
EXTERIOR STUCCO FINISH PER PLAN, REF.
5/AD-1 & A/A-4.0INTERIORCAULK, SEAL & SOLDER AS REQUIERD
TAPE FLASHING
1/2"1/2"
RAKE SUPPORT TRIM PER MFG'R.
ACM EXTERIOR FINISH, INSTALL PER MFG'R. SPECS
AND GUIDELINES, ARCH. TO APPV. COLOR & REVEAL
CAULK & SEAL AS REQUIERD
FLASHING W/. DRIP EDGE
TAPE FLASHING
ROOF RAFTER PER STRUCT.WALL STUDS PER STRUCT.*UNVENTED ENCLOSED RAFTER
ASSEMBLY NOTE:
NO INTERIOR CLASS I VAPOR
RETARDER SHALL BE INSTALLED
ON THE CEILING SIDE (ATTIC
FLOOR) OF THE UNVENTED
ATTIC ASSEMBLY OR ON THE
CEILING SIDE OF THE UNVENTED
ENCLOSED ROOF FRAMING
ASSEMBLY.
R-5 SPRAYED AIR-IMPERMEABLE INSULATION PER TABLE R806.5
R-5 RIGID AIR-IMPERMEABLE INSULATION PER
TABLE R806.5
AIR-PERMEABLE INSULATION (PER PLANS & T24)
3X10 FASCIA
BLD'G. WRAP - 'TYVEK' OR EQUIV.
STANDING SEAM METAL ROOFING W/. LAPPED, SEALED & SOLDERED SEAM PER
R905.10.2
15/32" CDX PLYWD. SHT'G. MIN. (REF. STRUCT)
(1) LAYER TYPE II (NO. 30) ROOF FELT-(2) LAYERS GAF VERSASHIELD UNDERLAYMENT
RAKE FLASHING W/. DRIP EDGE PER
ROOFING MFG'R.
CAULK, SEAL & SOLDER AS REQUIERD
CAULK & SEAL AS REQUIERD
NOTE:INSTALL ROOF &
SEALANTS AND SOLDER
SEAMS PER ROOFING
MFG'R. INSTALLATION
INSTRUCTION AND
SECTION R905.10.2.
EXTERIOR
NUSKU TERRATEK (ENGINEERED WESTERN RED
CEDAR) 1X6 T&G FINE LINE, REF. MAT. SCHED.
A/A-4.0, INSTALL PER MFGR. GUIDELINE
ACM FASCIA WRAP, INSTALL PER MFG'R. SPECS
AND GUIDELINES, ARCH. TO APPV. COLOR & REVEAL
INTERIOR
CAULK, SEAL & SOLDER AS REQUIERD
TAPE FLASHING
1/2"
RAKE SUPPORT TRIM PER MFG'R.
ROOF RAFTER PER STRUCT.
STRUCTURAL BEAM/OUTLOOKER, SIZE PER
STRUCT. - PAINT/STAIN & SEAL AS REQUIRED
ARCH TO APPV. CUT PROFILE & COLOR
FENESTRATION PER PLANS, SHGC AND U-VALUE
PER T-24, REF. T-24 SHEETS, INSTALL PER MFG'R.
JOB NO.
DATE
DOCUMENT VALID UPON
ORIGINAL SIGNATURE
SHEET NO.
REVISIONSOWNER INFORMATION:PROJECT NAME
STATUS
These documents are the property of BRANDON ARCHITECTS, Christopher Brandon, principal architect, and are not to be duplicated, altered or utilized in any way by any other party without the expressed authorization of BRANDON ARCHITECTS. Any unauthorized duplication or alteration of these documents by any party is a violation of BRANDON ARCHITECTS expressed common law copyright and other property rights thereto, and is subject to full civil liabilities and penalties. These plans are also not to be assigned to any third party without obtaining written authorization and expressed permission by BRANDON ARCHITECTS, who shall then be held harmless and absolved of any liability regarding any use of these documents by such third party, whether depicted or implied hereon.PROJECT ARCHITECT
AD-3.0
09/18/20
201932ROOF, EAVE, RAKE & PARAPETDETAILSCONWAY RESIDENCE
CONWAY RESIDENCEMARK CONWAY2 TWIN LAKES CIRCLECORONA DEL MARCA 92625PERMIT
2 TWIN LAKE CR, CORONA DEL MAR, CA 92625TYLER WILSON, AIA
N.T.S.1 METAL ROOFING DETAIL W/. 2:12 MIN. SLOPE
N.T.S.2 METAL ROOFING DETAIL W/. 2:12 MIN. SLOPE
N.T.S.3 METAL ROOFING DETAIL W/. 1/2:12 MIN. SLOPE
N.T.S.4 METAL ROOFING DETAIL W/. 1/2:12 MIN. SLOPE
N.T.S.5 METAL ROOFING DETAIL W/. 1/4:12 MIN. SLOPE
N.T.S.6 METAL ROOFING DETAIL W/. 1/4:12 MIN. SLOPE
N.T.S.7 METAL ROOF TO WALL CONNECTION (SIDE WALL)
N.T.S.8 METAL ROOF TO WALL CONNECTION (HEAD WALL)
N.T.S.9 EAVE DETAIL @ YOGA
NO. REVISION DATE
N.T.S.10 EAVE DETAIL @ SECOND FLOOR
N.T.S.11 RECESSED GUTTER DETAIL @ 2ND FLOOR
N.T.S.12 PARPET DETAIL @ LOW SLOPE SS METAL ROOF
N.T.S.13PARPET DETAIL @ LOW SLOPE SS METAL ROOF
N.T.S.14PARPET SIDEWALL @ LOW SLOPE SS METAL ROOF
N.T.S.15EAVE DETAIL @ MASTER SUITE
N.T.S.16PEAK DETAIL @ MASTER SUITE
N.T.S.18PEAK DETAIL @ GREAT ROOM
N.T.S.17RAKE DETAIL @ MASTER SUITE
N.T.S.19RAKE DETAIL @ GREAT ROOM
INSTALL DIRECTLY ABV. THE STRUCTURAL ROOF
SHEATHING
2% MIN. (1/4:12)
7 1/4"
45.00°
AIR-PERMEABLE INSULATION
(PER PLANS & T24)
CEILING FINISH PER PLANS
ROOFING PER PLANS
(1) LAYER TYPE II (NO.30) ROOF FELT - (2) LAYERS GAF VERSASHEILD UNDERLAYMENT
15/32" CDX PLYWD. SHT'G. MIN. (REF. STRUCT)
R-5 SPRAYED AIR-IMPERMEABLE INSULATION PER TABLE R806.5
METAL DRIP EDGE TO
MATCH ROOFING
METAL DEBRIS & LEAF
GUARD TO MATCH GUTTER
FINISH
CUSTOM BUILT KYNAR
PAINTED ALUM./STEEL
GUTTER W/. DRIP EDGE TO
MATCH METAL ROOFING -
VERIFY W/. ROOF MFGR.
SPECS AND WARRANTY
CAULT & SEAL AS REQ'D.
ACM PANEL, INSTALL PER
MFG'R. SPECS &
GUIDELINES, ARCH. TO
APPV. COLOR & REVEAL
TAPE FLASHING
MOLDED FOAM
BLD'G. WRAP - 'TYVEK'
OR EQUIV.
CAULK & SEAL AS REQ'D.
R-5 RIGID AIR-IMPERMEABLE
INSULATION PER TABLE R806.5
NOTE: INSTALL ROOF, SEALANTS,
& SOLDER SEAMS PER ROOFING
MFG'R. INSTALLATION
INSTRUCTION AND SECTION
R905.10.2*UNVENTED ENCLOSED
RAFTER ASSEMBLY NOTE:
NO INTERIOR CLASS I VAPOR
RETARDER SHALL BE INSTALLED
ON THE CEILING SIDE (ATTIC
FLOOR) OF THE UNVENTED ATTIC
ASSEMBLY OR ON THE CEILING
SIDE OF THE UNVENTED ENCLOSED
ROOF FRAMING ASSEMBLY
13.01 CRICKET
2% MIN
SCALE: 1/4" = 1'-0"1ARCHITECTURAL ROOF PLAN
2 EAVE DTL. (1-HR)
1 1/2"= 1'-0"3 RAKE DTL. (1-HR)
1 1/2"= 1'-0"4 STANDING SEAM ROOFING (TYP.)5 RECESSED GUTTER DTL.
1 1/2"= 1'-0"
BRANDON ARCHITECTS
DATE
A-4.0
PROJECT CONTACT
JEFF VAN VOORHIS, AIA
PROJECT NAME
PROJECT ADDRESS
908 W. OCEANFRONT
NEWPORT BEACH, CA 92661
OWNER INFORMATION
908 NB PROPERTY MANAGEMENT LLC
3717 EUCLID AVE.
DALLAS, TX
PROJECT STATUS
SECOND CHECK
PLAN CHECK NO.
TBD
REVISIONS
NO.
DATE
5/28/2021 HARVEY RESIDENCEEXTERIOR
ELEVATIONS
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
REVISIONS
These documents are the property of BRANDON
ARCHITECTS INC., and are not to be duplicated,
altered or utilized in any ay by any other party
without the expressed authorization of
BRANDON ARCHITECTS. Any unauthorized
duplication or alteration of these documents by
any party is a violation of BRANDON
ARCHITECTS expressed common law copyright
and other property rights thereto, and is subject
to full civil liabilities and penalties. These plans
are also not to be assigned to any third party
without obtaining written authorization and
expressed permission by BRANDON
ARCHITECTS, who shall then be held harmless
and absolved of any liability regarding any use
of these documents by such third party whether
depicted or implied hereon.
C KEYNOTES
A MATERIAL SPECIFICATIONS
B GENERAL NOTES
WINDOWS & DOORS:
AUTHORIZED DEALER (PRODUCTS LISTED BELOW)
SUPPLIER: ASSOCIATED BUILDING SUPPLY
ADDRESS: STONE MILL DESIGN CENTER 2915 RED HILL AVE., SUITE F104, COSTA MESA, CA 92626
CONTACT: JOE YOUNAN
PHONE: 949-872-3319
FAX: 206-666-2150
EMAIL: JYOUNAN@ABSSOCAL.COM
WEB: WWW.ASSOCIATEDBUILDINGSUPPLY.COM
ALUMINUM CLAD WINDOWS & PATIO DOORS
MANUFACTURER: JELD-WEN WINDOWS & DOORS
PRODUCT: CUSTOM COLLECTION
ADDRESS: 3250 LAKEPORT BLVD. P.O. BOX 1329; KLAMATH FALLS, OREGON 97601
PHONE: 541-885-7412 OR 800-535-3936FAX: 541-884-3331
WEB: WWW.JELD-WEN.COM
MULTI SLIDE DOORS & STOREFRONT
MANUFACTURER: WESTERN WINDOW SYSTEMS
PRODUCT: SERIES 600 & STOREFRONT SYSTEMS
ADDRESS: 5621 S. 25TH ST., PHOENIX, AZ 85040
PHONE: 877.268.1300
WEB: WWW.WESTERNWINDOWSYSTEMS.COM
EXTERIOR STUCCO:
MANUFACTURER: MERLEX STUCCO
2911 ORANGE-OLIVE ROAD
ORANGE, CA 92865
P: 714.627.1700COLOR: WHITE, ARCH. TO APPV.
APPLICATION: THREE-COAT APPL., SMOOTH 7/8" W/. METAL LATH (DIAMOND OR EQUIV.)
WOOD (EAVES):
SUPPLIER: TBD
TYPE: CLEAR-HEART HARDWOOD, CEDAR, OAK OR AS SEL. ARCH & CLIENT TO APPV.
SIZE:
TYPICAL EAVES: 1X6 T&G (TYP. EAVES)
MASTER BEDROOM EAVES: 2X4 MIXED WITH 1X6 PANELS
FINISH: CLEAR SEALANT, SEMI-GLOSS, CORD. W/. ARCH.
APPLICATION:
TYPICAL EAVEAS: T&G W/. SIMPLE REVEAL (COORD. WITH ARCH.) - SCORE & BACKPRIME
MASTER BEDROOM EAVES: 2X4 PIECES SPACED AT 3 1/2" O.C., 1X PANELS IN BEWEEN. (REF. DETLS,
ARCH. TO APPV. LAYOUT)
EXTERIOR STONE VENEER:
MANUFACTURER: TBD
STONE TYPE: STACKED LIMESTONE
COLOR: CREAM/OFF-WHITE, ARCH. TO APPV.
APPLICATION: TIGHT FITTING, APPX. 4" X 36" TILES (ARCH TO APPV. G.C. TO PROVIDE SAMPLE & MOCK-UPS)
THICKNESS: 1" -1.5" NOMINAL
WEIGHT: LESS THAN 15 LBS. / S.F.
METAL PANELS (FASCIA AND SIDING):
MANUFACTURER: TBD
COLOR: DK. GREY TO MATCH ROOF COLOR. ARCH. TO APPV.
FINISH: KYNAR PAINTED ALUM. ACM PANEL - ARCH. TO APPV. SIZING
ROOFING - METAL (CLASS-A):
PRODUCT: STANDING SEAM METAL - KYNAR FINISH
MFGR: CUSTOM-BILT METALS 13940 MAGNOLIA AVE.
CHINO, CA. 91710
P: 909.664.1500
COLOR: GRAY - TO BE APPROVED BY ARCH. & OWNER
APPLICATION: USE CONTINUOUS 16" OR 18" PANS - VERIFY W/. ARCH. SIZE & LOC'N. OF SEAMS. (NO TRANSVERSE SEAMS)
CODE: ESR-2048
WEIGHT: APPX. 2 PSF.
ROOFING - TPO (CLASS-A):
PRODUCT: TPO MEMBRANE
MFGR: GAF, EVERGUARD - WWW.GAF.COM
COLOR: ENERGY GRAY 322 (COOL COLOR TECH.)
APPLICATION: INSTALL PER MFGR.
CODE: ICC-CLASS A ASSEMBLY (ICC# ESR-1597)
WEIGHT: N/A
GUTTERS:
MATERIAL: METAL - ALUM. PAINTED KYNAR
SHAPE: SQUARE (5") (VERIFY W/. ARCH.)
GARAGE DOORS:
SUPPLIER: RANCH HOUSE DOORS
WEB: WWW.RANCHHOUSEDOORS.COMSTYLE: CUSTOM
MATERIAL: CUSTOM BUILT, WOOD & GLASS
WATERPROOF DECK MEMBRANE:
MFGR: TUFFLEX POLYMERS
ADDRESS: 10880 POPLAR AVE., FONTANA, CA
PHONE: 909.349.2016
WEB: WWW.TUFFLEXPOLYMERS.COM
CODE: ICC # ESR-2505
FLASHING & WEATHERSTRIPPINGPROVIDE MIN. 24 GUAGE METAL (16 OZ.) SHEETING (TO MATCH) FOR ALL EXTERIOR FLASHING & WEATHERSTRIPPING
APPLICATIONS. VERIFY W/. ARCHITECT ANY UNCONVENTIONAL ENVELOPE WATERPROOFING AREAS PRIOR TO INSTALLATION.
1. FENESTRATIONS MUST HAVE TEMPORARY AND PERMANENT LABELS.
2. REF. ROOF PLAN (A-3) FOR ALL PLATE HTS. & RIDGE HTS.
12 3 123123 12 3 12 3
123 123
6
AD-1.0
13
AD-1.0
3
A-3.0
15
AD-1.0
5
A-3.0
11.80'
FIRST FLOOR F.F.
11.80'
FIRST FLOOR F.F.
22.30'
SECOND FLOOR F.F.
22.30'
SECOND FLOOR F.F.
31.47'
THIRD FLOOR F.F.
31.47'
THIRD FLOOR F.F.
38.38'
ROOF PLATE
38.38'
ROOF PLATE
11.36' GRADE PLANE
35.36' MAX. FLAT
40.36' MAX. HEIGHT
10'-6"9'-2"6'-11"40.36' HT. CERT. REQ'D.
25.38' T.R.42" MIN.ABV. F.F.24'-0"29'-0"8'-6"HD. HT.8'-11"HD. HT.6'-8"HD. HT. MASONRY - STONE
METAL - ACM PANEL
10.01
10.01
MASONRY - STONE
METAL - ACM PANEL
STUCCO
STUCCO
STEEL POST - REF. STRCT.
STUCCO STEEL POST - REF. STRCT.
STUCCO
STEEL POST - REF. STRCT.
STUCCO
<Hotlink ID><ID>
A2
6
12
30
PLPL
121
6
AD-1.0
5
AD-1.0
5
AD-1.0
2
A-3.0
16
AD-1.0
15
AD-1.0
15
AD-1.0
5
A-3.0
11.80'
FIRST FLOOR F.F.
11.80'
FIRST FLOOR F.F.
22.30'
SECOND FLOOR F.F.
22.30'
SECOND FLOOR F.F.
31.47'
THIRD FLOOR F.F.
31.47'
THIRD FLOOR F.F.
38.38'
ROOF PLATE
38.38'
ROOF PLATE
40.30'40.30'
35.34' T.R.
31.97'
32.69'
35.34'42" MIN.ABV. F.F.42" MIN.ABV. F.F.35.36' MAX. FLAT
40.36' MAX. RIDGE
11.36' GRADE PLANE24'-0"29'-0"3'-0"SILL HT.8'-10 5/8"HD HT.3'-6 3/8"SILL HT.6'-6 3/8"HD HT.8'-6 1/4"HD HT.3'-0"SILL HT.5'-6 3/4"SILL HT.STEEL POST - REF. STRCT.
10.01
MASONRY - STONE
METAL - ACM PANEL
STUCCO
STUCCO
METAL - ACM PANEL
METAL - ACM PANEL
METAL - ACM PANEL
METAL - ACM PANEL
MASONRY - STONE
METAL - ACM PANEL
STUCCO
METAL - ACM PANEL
STUCCO
ROOFING - METAL
STUCCO
STUCCO
22.17
A1
9
14
26
12 1113
27
28
24
3
10
25
PL
12 3123
12 3123 123 123
121 12 1
5
AD-1.0
5
AD-1.0
3
A-3.0
16
AD-1.0
15
AD-1.0
11.80'
FIRST FLOOR F.F.
11.80'
FIRST FLOOR F.F.
22.30'
SECOND FLOOR F.F.
22.30'
SECOND FLOOR F.F.
31.47'
THIRD FLOOR F.F.
31.47'
THIRD FLOOR F.F.
38.38'
ROOF PLATE
38.38'
ROOF PLATE
10'-6"9'-2"6'-11"40.36' HT. CERT. REQ'D.
32.69'32.69'
35.36' MAX FLAT.
40.36' MAX. HEIGHT
9'-0"HD.HT.9'-0"HD.HT.#Material tags
#Material tags #Material tags
MASONRY - STONE
METAL - ACM PANEL
STUCCO
METAL - ACM PANEL
STUCCO STUCCO
METAL - ACM PANEL
STUCCO
MASONRY - STONE
METAL - ACM PANEL
STUCCO
METAL - ACM PANEL
1415
23
PLPL
12 1
6
AD-1.0
5
AD-1.0
5
AD-1.0
2
A-3.0
16
AD-1.0
15
AD-1.0
5
A-3.0
11.80'
FIRST FLOOR F.F.
11.80'
FIRST FLOOR F.F.
22.30'
SECOND FLOOR F.F.
22.30'
SECOND FLOOR F.F.
31.47'
THIRD FLOOR F.F.
31.47'
THIRD FLOOR F.F.
38.38'
ROOF PLATE
38.38'
ROOF PLATE
10'-6"9'-2"6'-11"11.36' GRADE PLANE
35.36' MAX FLAT.
40.36' MAX. HEIGHT40.30' HT. CERT. REQ'D.
35.34' T.R.HT. CERT. REQ'D.
31.97'
40.30' HT. CERT. REQ'D.
34.09'
32.69'
40.36' HT. CERT. REQ'D.
25.38' T.R.42" MIN.ABV. F.F.42" MIN.ABV. F.F.42" MIN.ABV. F.F.24'-0"29'-0"8'-6"HD. HT.7'-6"HD. HT.7'-6"6'-8"HD. HT.8'-0"HD. HT.8'-6"HD. HT. MASONRY - STONE
10.01
10.01
METAL - ACM PANEL
STUCCO
MASONRY - STONE
METAL - ACM PANEL
STUCCO
METAL - ACM PANEL
STUCCO
ROOFING - METAL
STUCCO
ROOFING - METAL
STUCCO
STEEL POST - REF. STRCT.
22.17
22.17
A3
4
2021
5
5
18 1719 16
30 29
23
7 6
PLPL
10.01 EXTERIOR GLASS GUARDRAIL
TEMPERED & LAMINATED - MIN. 42" HIGH - 4" MAX. SPHERE OPENING, REF. DTL. 4/AD-1
22.17 DOWNSPOUT
ALUMINUM W/. KYNAR FINISH OR EQUIV. - AS SEL. (ARCH. TO APPROVE)
SCALE: 1/4" = 1'-0"2SOUTH ELEVATION
SCALE: 1/4" = 1'-0"4WEST ELEVATION
SCALE: 1/4" = 1'-0"3NORTH ELEVATION
SCALE: 1/4" = 1'-0"1EAST ELEVATION
BRANDON ARCHITECTS
DATE
A-5.0
PROJECT CONTACT
JEFF VAN VOORHIS, AIA
PROJECT NAME
PROJECT ADDRESS
908 W. OCEANFRONT
NEWPORT BEACH, CA 92661
OWNER INFORMATION
908 NB PROPERTY MANAGEMENT LLC
3717 EUCLID AVE.
DALLAS, TX
PROJECT STATUS
SECOND CHECK
PLAN CHECK NO.
TBD
REVISIONS
NO.
DATE
5/28/2021 HARVEY RESIDENCEARCHITECTURAL
SECTIONS
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
REVISIONS
These documents are the property of BRANDON
ARCHITECTS INC., and are not to be duplicated,
altered or utilized in any ay by any other party
without the expressed authorization of
BRANDON ARCHITECTS. Any unauthorized
duplication or alteration of these documents by
any party is a violation of BRANDON
ARCHITECTS expressed common law copyright
and other property rights thereto, and is subject
to full civil liabilities and penalties. These plans
are also not to be assigned to any third party
without obtaining written authorization and
expressed permission by BRANDON
ARCHITECTS, who shall then be held harmless
and absolved of any liability regarding any use
of these documents by such third party whether
depicted or implied hereon.
A FIRE-BLOCKING & DRAFT STOP NOTES
B INSULATION SCHEDULE
C ANNOTATION LEGEND
D KEYNOTES
FIREBLOCKING AND DRAFTSTOPPING SHALL BE INSTALLED TO CUT OFF ALL CONCEALED DRAFT OPENINGS (BOTH VERTICAL AND
HORIZONTAL) AND SHALL FORM AN EFFECTIVE BARRIER BETWEEN FLOORS, BETWEEN A TOP STORY AND A ROOF OR ATTIC SPACE,
AND SHALL SUBDIVIDE ATTIC SPACES, CONCEALED ROOF SPACES AND FLOOR-CEILING ASSEMBLIES. THE INTEGRITY OF ALL FIRE
BLOCKS AND DRAFT STOPS SHALL BE MAINTAINED.
FIRE BLOCKS
FIREBLOCKING SHALL BE PROVIDED IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES, AT THE
CEILING AND FLOOR LEVELS AND AT 10-FOOT INTERVALS BOTH VERTICAL AND HORIZONTAL.
FIRE BLOCK CONSTRUCTION
FIREBLOCKING SHALL CONSIST OF 2 INCHES NOMINAL LUMBER. FIRE BLOCKS MAY ALSO BE OF GYPSUM BOARD, CEMENT FIBER
BOARD, BATTS OR BLANKETS OF MINERAL OR GLASS FIBER, OR OTHER APPROVED MATERIALS INSTALLED IN SUCH A MANNER AS TOBE SECURELY RETAINED IN PLACE. LOOSE-FILL INSULATION MATERIAL SHALL NOT BE USED.
WALLS HAVING PARALLEL OR STAGGERED STUDS FOR SOUND-TRANSMISSION CONTROL SHALL HAVE FIRE BLOCKS OF BATTS OR
BLANKETS OF MINERAL OR GLASS FIBER OR OTHER APPROVED FLEXIBLE MATERIALS.
DRAFT STOPS
DRAFTSTOPPING SHALL BE PROVIDED IN THE LOCATIONS SET FORTH IN THIS SECTION.
FLOOR-CEILING ASSEMBLIES
DRAFT STOPS SHALL BE INSTALLED IN FLOOR-CEILING ASSEMBLIES OF THE BUILDING. SUCH DRAFT STOPS SHALL BE IN LINE WITH
WALLS SEPARATING INDIVIDUAL DWELLING UNITS FROM EACH OTHER AND FROM OTHER AREAS.
ATTICS
DRAFT STOPS SHALL BE INSTALLED IN THE ATTICS, MANSARDS, OVERHANGS, FALSE FRONTS SET OUT FROM WALLS AND SIMILAR
CONCEALED SPACES OF THIS BUILDING. SUCH DRAFT STOPS SHALL BE ABOVE AND IN LINE WITH THE WALLS SEPARATING
INDIVIDUAL DWELLING UNITS FROM EACH OTHER AND FROM OTHER USES.
DRAFT STOP CONSTRUCTION
DRAFTSTOPPING MATERIALS SHALL NOT BE LESS THAN ½-INCH GYPSUM BOARD, 3/8-INCH WOOD STRUCTURAL PANEL, 3/8-INCH
TYPE 2-M PARTICLEBOARD OR OTHER APPROVED MATERIALS ADEQUATELY SUPPORTED.
OPENINGS IN THE PARTITIONS SHALL BE PROTECTED BY SELF-CLOSING DOORS WITH AUTOMATIC LATCHES CONSTRUCTED AS
REQUIRED FOR THE PARTITIONS.
EXTERIOR WALL:
2 x 4 CONST.: R-21 MIN.
2 x 6 CONST. OR LARGER: R-21 MIN.
RAISED FLOOR: R-30 MIN.
ROOF: R-30
ROOF+ATTIC: R-30 + R-15
NOTES:
1. REF. T-24 REPORT FOR MORE INFORMATION
2. PROVIDE BID FOR INSULATION OF ENTIRE HOME
*TOTAL R-VALUE INCLUDING THE RIDGID AND SPRAYED AIR-IMPERMEABLE INSULATION WHERE OCCURS FOR UNVENTED ASSEMBLY
13
AD-1.0
13
AD-1.0
7
AD-1.0
7
AD-1.0
14
AD-1.0
5
A-3.0
3
A-3.0
3
A-3.0
16
AD-1.0
11.80'
FIRST FLOOR F.F.
11.80'
FIRST FLOOR F.F.
22.30'
SECOND FLOOR F.F.
22.30'
SECOND FLOOR F.F.
31.47'
THIRD FLOOR F.F.
31.47'
THIRD FLOOR F.F.
38.38'
ROOF PLATE
38.38'
ROOF PLATE
9'-3 1/2"9'-3 1/2"7'-11 1/2"7'-11 1/2"9'-0"35.36' MAX. FLAT
40.36' MAX. HEIGHT
42" MIN.ABV. F.F.8'-11"7'-11 1/2"7'-11 1/2"8'-6 3/4"42" MIN.ABV. F.F.6'-0"MAX.6 1/2"12.01
12.01
06.49
12.01
06.41
26.10
06.46
22.08
06.4406.44
06.42
06.42
11.04
12.01 12.01 12.01
12.0112.01
12.01
10.01
10.01
10.14
06.01 06.01 06.01 06.01 06.01
06.01
03.03 03.03
06.0206.02
06.02
05.01
05.02
06.04
06.0406.04
06.02
2% MIN.
Door Window Label 24
This label is not available for Independent Labels.
2% MIN.2% MIN.
Door Window Label 24
This label is not available for Independent Labels.
Door Window Label 24
This label is not available for Independent Labels.
Door Window Label 24
This label is not available for Independent Labels.
Door Window Label 24
This label is not available for Independent Labels.
Door Window Label 24
This label is not available for Independent Labels.
BED #3
MECH.
GARAGE
MECH. /
ATTIC
MASTER
SUITE
GREAT ROOM KITCHEN
BONUS
ROOM
SAND ROOM
BED #5 BATH #5 BED #2 BATH #2
5
A-3.0 5
A-3.0
11.80'
FIRST FLOOR F.F.
11.80'
FIRST FLOOR F.F.
22.30'
SECOND FLOOR F.F.
22.30'
SECOND FLOOR F.F.
31.47'
THIRD FLOOR F.F.
31.47'
THIRD FLOOR F.F.
38.38'
ROOF PLATE
38.38'
ROOF PLATE
8'-11"8'-6 1/8"8'-6 1/8"35.36' MAX. FLAT
40.36' MAX. HEIGHT
42" MIN.ABV. F.F.42" MIN.ABV. F.F.10'-6"9'-2"6'-11"3'-5 3/4"26.10
06.34
12.01
12.01
10.12
26.10
12.01
10.12
06.31
06.02 06.02
06.01 06.01
06.49
06.03 06.03
12.01
3 :12 3 :12 3 :12 3:123:123:12
MASTER SUITE
MASTER
RETREAT
LOUNGE GREATROOM
PL.PL.
7
AD-1.0
14
AD-1.0
14
AD-1.0
16
AD-1.0
16
AD-1.0
11.80'
FIRST FLOOR F.F.
11.80'
FIRST FLOOR F.F.
22.30'
SECOND FLOOR F.F.
22.30'
SECOND FLOOR F.F.
31.47'
THIRD FLOOR F.F.
31.47'
THIRD FLOOR F.F.
38.38'
ROOF PLATE
38.38'
ROOF PLATE
9'-0"9'-0"9'-0"10'-6"9'-2"6'-11"35.36' MAX FLAT
40.36' MAX SLOPE
2% MIN
12.01 12.01
22.08
06.04
06.04 06.04
06.01
34.01 34.01
3 :12 3 :12 3 :12 3:123:123:12
1 :12 1:12
25
PL.PL.
3-CAR GARAGE
ATTIC
BEDROOM #3 BEDROOM #4BATH #3
ROOM NAME
1
AD-1.0
1
15'-6"
1
A-5.0
1
01.13
1-HR RATED EXT CONDITION - REF. DTLS. 14/AD-1
1-HR RATED INT CONDITION - REF. DTLS. 7/AD-1
UNVENTED ROOF ASSEMBLY ROOF FRAMING - PER STRUCT., REF. STRUCT.
DWGS. – UNVENTED ASSEMBLY TO COMPLY W/. SECTION R806.5 OF CRC, AIR-
IMPERMEABLE VALUE PER TABLE R806.5 OF CRC
INSULATED BUILDING ENVELOPE - 2X STUDS PER PLANS, SEE DIMENSION PLANS
FOR MORE INFO – INSULATION PER INSULATION SCHEDULE AND T-24 ENERGY REPORTS
1i WINDOW TAG
DOOR TAG
CALL-OUT TAG
REVISION TAG
ROOM TAG
VENTED ROOF ASSEMBLY ROOF FRAMING - PER STRUCT., REF. STRUCT. DWGS. –
PROVIDE CROSS VENTILATION PER SECTION R806 OF CRC, SEE ROOF PLAN SHEET A-3.0
FOR ATTIC VENT CALC AND MORE INFO
1-HR RATED FLOOR/CEILING ASS'Y - REF. DTLS. 7/AD-1
CONCRETE WALL / PODIUM DECK - PER STRUCT. REF. STRUCT DWGS. – FOR SLAB
ON GRADE PROVIDE BASE PER R506.2.2 AND VAPOR RETARDER PER R506.2.3 W/.
CAPILLARY BREAK
SECTION INDICATOR
SPOT ELEVATION
KEYNOTE TAG
03.03 MAT SLAB
REF. STRUCT.
05.01 EXPOSED STEEL BEAM
SIZE PER STRUCT. DWGS., PAINT AND SEAL AS REQ'D.
05.02 EXPOSED STEEL COLUMN
SIZE PER STRUCT. DWGS., PAINT AND SEAL AS REQ'D.
06.01 FLOOR JOISTS - REF. STRUCT.
06.02 DECK FRAMING - REF. STRUCT.
06.03 CEILING FRAMING - REF. STRUCT.
06.04 ROOF RAFTERS - REF. STRUCT.
06.31 DESK
BUILT-IN, FINISH AS SEL.06.34 KITCHEN ISLAND
BASE CABINET, COUNTER, AND APPLIANCES PER I.D - VERIFY SIZE W/. I.D. & OWNER
06.41 TALL CABINET
BUILT-IN, FINISH AS SEL.
06.42 UPPER CABINET
BUILT-IN, FINISH AS SEL.
06.44 BASE CABINET & COUNTER
BUILT-IN, FINISH AS SEL.
06.46 KITCHEN SINK CASEWORK
SINK, BASE CABINET AND COUNTER - VERIFY SIZE/. I.D. & OWNER
06.49 SHELF
BUILT-IN, FINISH AS SEL.
10.01 EXTERIOR GLASS GUARDRAIL
TEMPERED & LAMINATED - MIN. 42" HIGH - 4" MAX. SPHERE OPENING, REF. DTL. 4/AD-1
10.12 CUSTOM WOOD SCREEN
WOOD SCREEN PER I.D. ARCH TO APPV. SHOP DWGS. PRIOR TO FABRICATION
10.14 TEMPERED GLASS WINDOW WALLREF. WINDOW WALL SCHEDULE A-7.0
11.04 STACKED WASHER/DRYER
PROVIDE 4" MIN. DIA. DUCT, 14' MAX. LENGTH INCLUDING (2) 90 DEGREE ELBOWS, DEDUCT TWO(2) FEET FOR EACH 90
DEGREE ELBOW IN EXCESS OF TWO(2) (CMC 504.3.2)
12.01 FURNISHINGS
AS SELECTED
22.08 TOILET
MIN. 24" CLR. IN FRONT, MIN. 30"" CLR. WIDTH, REF. CAL GREEN NOTES FOR FLOW RATE INFO.
26.10 DECORATIVE PENDANT LIGHT FIXTURE
34.01 VEHICLE
MINIMUM PARKING DIMENSIONS ON PLANS
SCALE: 1/4" = 1'-0"3LONGITUDINAL SECTION
SCALE: 1/4" = 1'-0"2TRANSVERSE SECTION
SCALE: 1/4" = 1'-0"1TRANSVERSE SECTION
BRANDON ARCHITECTS
DATE
A-5.1
PROJECT CONTACT
JEFF VAN VOORHIS, AIA
PROJECT NAME
PROJECT ADDRESS
908 W. OCEANFRONT
NEWPORT BEACH, CA 92661
OWNER INFORMATION
908 NB PROPERTY MANAGEMENT
LLC
DEREK & MEGAN HARVEY
3717 EUCLID AVE.
DALLAS, TX
PROJECT STATUS
SECOND CHECK
PLAN CHECK NO.
TBD
REVISIONS
NO.
DATE
04/01/21 HARVEY RESIDENCEARCHITECTURAL
SECTIONS
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
REVISIONS
These documents are the property of BRANDON
ARCHITECTS INC., and are not to be duplicated,
altered or utilized in any ay by any other party
without the expressed authorization of
BRANDON ARCHITECTS. Any unauthorized
duplication or alteration of these documents by
any party is a violation of BRANDON
ARCHITECTS expressed common law copyright
and other property rights thereto, and is subject
to full civil liabilities and penalties. These plans
are also not to be assigned to any third party
without obtaining written authorization and
expressed permission by BRANDON
ARCHITECTS, who shall then be held harmless
and absolved of any liability regarding any use
of these documents by such third party whether
depicted or implied hereon.
A FIRE-BLOCKING & DRAFT STOP NOTES
B INSULATION SCHEDULE
C ANNOTATION LEGEND
D KEYNOTES
FIREBLOCKING AND DRAFTSTOPPING SHALL BE INSTALLED TO CUT OFF ALL CONCEALED DRAFT OPENINGS (BOTH VERTICAL AND
HORIZONTAL) AND SHALL FORM AN EFFECTIVE BARRIER BETWEEN FLOORS, BETWEEN A TOP STORY AND A ROOF OR ATTIC SPACE,
AND SHALL SUBDIVIDE ATTIC SPACES, CONCEALED ROOF SPACES AND FLOOR-CEILING ASSEMBLIES. THE INTEGRITY OF ALL FIRE
BLOCKS AND DRAFT STOPS SHALL BE MAINTAINED.
FIRE BLOCKS
FIREBLOCKING SHALL BE PROVIDED IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES, AT THE
CEILING AND FLOOR LEVELS AND AT 10-FOOT INTERVALS BOTH VERTICAL AND HORIZONTAL.
FIRE BLOCK CONSTRUCTION
FIREBLOCKING SHALL CONSIST OF 2 INCHES NOMINAL LUMBER. FIRE BLOCKS MAY ALSO BE OF GYPSUM BOARD, CEMENT FIBER
BOARD, BATTS OR BLANKETS OF MINERAL OR GLASS FIBER, OR OTHER APPROVED MATERIALS INSTALLED IN SUCH A MANNER AS TOBE SECURELY RETAINED IN PLACE. LOOSE-FILL INSULATION MATERIAL SHALL NOT BE USED.
WALLS HAVING PARALLEL OR STAGGERED STUDS FOR SOUND-TRANSMISSION CONTROL SHALL HAVE FIRE BLOCKS OF BATTS OR
BLANKETS OF MINERAL OR GLASS FIBER OR OTHER APPROVED FLEXIBLE MATERIALS.
DRAFT STOPS
DRAFTSTOPPING SHALL BE PROVIDED IN THE LOCATIONS SET FORTH IN THIS SECTION.
FLOOR-CEILING ASSEMBLIES
DRAFT STOPS SHALL BE INSTALLED IN FLOOR-CEILING ASSEMBLIES OF THE BUILDING. SUCH DRAFT STOPS SHALL BE IN LINE WITH
WALLS SEPARATING INDIVIDUAL DWELLING UNITS FROM EACH OTHER AND FROM OTHER AREAS.
ATTICS
DRAFT STOPS SHALL BE INSTALLED IN THE ATTICS, MANSARDS, OVERHANGS, FALSE FRONTS SET OUT FROM WALLS AND SIMILAR
CONCEALED SPACES OF THIS BUILDING. SUCH DRAFT STOPS SHALL BE ABOVE AND IN LINE WITH THE WALLS SEPARATING
INDIVIDUAL DWELLING UNITS FROM EACH OTHER AND FROM OTHER USES.
DRAFT STOP CONSTRUCTION
DRAFTSTOPPING MATERIALS SHALL NOT BE LESS THAN ½-INCH GYPSUM BOARD, 3/8-INCH WOOD STRUCTURAL PANEL, 3/8-INCH
TYPE 2-M PARTICLEBOARD OR OTHER APPROVED MATERIALS ADEQUATELY SUPPORTED.
OPENINGS IN THE PARTITIONS SHALL BE PROTECTED BY SELF-CLOSING DOORS WITH AUTOMATIC LATCHES CONSTRUCTED AS
REQUIRED FOR THE PARTITIONS.
EXTERIOR WALL:
2 x 4 CONST.: R-21 MIN.
2 x 6 CONST. OR LARGER: R-21 MIN.
RAISED FLOOR: R-30 MIN.
ROOF: R-30
ROOF+ATTIC: R-30 + R-15
NOTES:
1. REF. T-24 REPORT FOR MORE INFORMATION
2. PROVIDE BID FOR INSULATION OF ENTIRE HOME
*TOTAL R-VALUE INCLUDING THE RIDGID AND SPRAYED AIR-IMPERMEABLE INSULATION WHERE OCCURS FOR UNVENTED ASSEMBLY
13
AD-1.0
7
AD-1.07
AD-1.0
14
AD-1.0
8
AD-1.0
8
AD-1.0
5
A-3.0
3
A-3.0
3
A-3.0
16
AD-1.0
11.80'
FIRST FLOOR F.F.
11.80'
FIRST FLOOR F.F.
22.30'
SECOND FLOOR F.F.
22.30'
SECOND FLOOR F.F.
31.47'
THIRD FLOOR F.F.
31.47'
THIRD FLOOR F.F.
38.38'
ROOF PLATE
38.38'
ROOF PLATE
35.36' MAX FLAT
40.36' MAX SLOPE
10'-6"9'-2"6'-11"6 1/2"12.01
12.01
12.01
12.01
10.07
10.07
06.38
06.38
06.45
22.04
11.20
06.4906.49 06.41 06.41
03.03 03.03
03.03
06.01 06.01 06.01 06.01
06.0106.02 06.02
06.04
06.0406.04
35.34'
HT. CERT. REQ'D.
35.36'
HT. CERT. REQ'D.
2% MIN.2% MIN.
10.01
16R x 0'-6 7/8"
17R x 0'-7 3/8"9 4
12 13
28
24
3
10
3-CAR GARAGE
BED #3
BATH #6
MECH. /
ATTIC
DEN
GREAT ROOM KITCHEN
STAIRS
MASTER
BATH W.I.C.
FOYER.
BATH #2
STAIRS
8
AD-1.0
8
AD-1.0
2
A-3.0
2
A-3.0
11.80'
FIRST FLOOR F.F.
11.80'
FIRST FLOOR F.F.
22.30'
SECOND FLOOR F.F.
22.30'
SECOND FLOOR F.F.
31.47'
THIRD FLOOR F.F.
31.47'
THIRD FLOOR F.F.
38.38'
ROOF PLATE
38.38'
ROOF PLATE
10'-6"9'-2"6'-11"35.36' MAX FLAT
40.36' MAX SLOPE
1'-0"TYP.32" - 36" 32" TYP.42" MIN.ABV. F.F.1'-0"TYP.7 3/8"TYP.32" - 36" 32" TYP.6 7/8"16R x 0'-6 7/8"
17R x 0'-7 3/8"
06.30
06.30
12.01
12.01
10.15
10.15
10.15
06.04
06.04
06.04
03.03 03.03 03.03
06.01 06.01
06.01
3 :12 3 :12 3 :12 3:123:123:12
1:12
22
9 11
PL.PL.STAIR
STAIR
BONUS
ROOM
BEDROOM
#2
ROOM NAME
1
AD-1.0
1
15'-6"
1
A-5.0
1
01.13
1-HR RATED EXT CONDITION - REF. DTLS. 14/AD-1
1-HR RATED INT CONDITION - REF. DTLS. 7/AD-1
UNVENTED ROOF ASSEMBLY ROOF FRAMING - PER STRUCT., REF. STRUCT.
DWGS. – UNVENTED ASSEMBLY TO COMPLY W/. SECTION R806.5 OF CRC, AIR-
IMPERMEABLE VALUE PER TABLE R806.5 OF CRC
INSULATED BUILDING ENVELOPE - 2X STUDS PER PLANS, SEE DIMENSION PLANS
FOR MORE INFO – INSULATION PER INSULATION SCHEDULE AND T-24 ENERGY REPORTS
1i WINDOW TAG
DOOR TAG
CALL-OUT TAG
REVISION TAG
ROOM TAG
VENTED ROOF ASSEMBLY ROOF FRAMING - PER STRUCT., REF. STRUCT. DWGS. –
PROVIDE CROSS VENTILATION PER SECTION R806 OF CRC, SEE ROOF PLAN SHEET A-3.0
FOR ATTIC VENT CALC AND MORE INFO
1-HR RATED FLOOR/CEILING ASS'Y - REF. DTLS. 7/AD-1
CONCRETE WALL / PODIUM DECK - PER STRUCT. REF. STRUCT DWGS. – FOR SLAB
ON GRADE PROVIDE BASE PER R506.2.2 AND VAPOR RETARDER PER R506.2.3 W/.
CAPILLARY BREAK
SECTION INDICATOR
SPOT ELEVATION
KEYNOTE TAG
2
A-3.0
2
A-3.0
7
AD-1.0
7
AD-1.0
14
AD-1.0
11.80'
FIRST FLOOR F.F.
11.80'
FIRST FLOOR F.F.
22.30'
SECOND FLOOR F.F.
22.30'
SECOND FLOOR F.F.
31.47'
THIRD FLOOR F.F.
31.47'
THIRD FLOOR F.F.
38.38'
ROOF PLATE
38.38'
ROOF PLATE
10'-6"9'-2"6'-11"BATH #4
BATH #6
3 :12 3 :12 3 :12 3:123:12
3:12 3 :12 3:12
1:12
2% MIN.
ELEV.
BATH #2
GARAGESAND ROOM
MECH.
03.03 MAT SLAB
REF. STRUCT.06.01 FLOOR JOISTS - REF. STRUCT.
06.02 DECK FRAMING - REF. STRUCT.
06.04 ROOF RAFTERS - REF. STRUCT.
06.30 COUNTERTOP
AS SELECTED
06.38 BUILT-IN CLOSET
CUSTOM PER INTERIOR DESIGNER
06.41 TALL CABINET
BUILT-IN, FINISH AS SEL.
06.45 VANITY CASEWORK
SINK, BASE CABINET AND COUNTER - VERIFY SIZE W/. I.D. & OWNER
06.49 SHELF
BUILT-IN, FINISH AS SEL.
10.01 EXTERIOR GLASS GUARDRAIL
TEMPERED & LAMINATED - MIN. 42" HIGH - 4" MAX. SPHERE OPENING, REF. DTL. 4/AD-1
10.07 STAIRS
MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS THAN 1 FOOT CANDLE(CBC 1205.4) REF. DTL. 3/AD-1
10.15 INTERIOR GLASS HANDRAIL
34" - 38" ABV. NOSING (36"" TYP. U.N.O.), REF. DTL. 4/AD-1
11.20 FIREPLACE
PREFABRICATED, GAS ONLY, 'DAVINCI - ISLAND' - ANSI Z21.50B-2014 [DTL. 22/AD-1] (FACTORY BUILT FIREPLACES,
CHIMNEYS, AND ALL OF THEIR COMPONENTS SHALL BE LISTED AND INSTALLED IN ACCORDANCE W/. THEIR LISTING AND
MFG'R. INSTALLATION INSTRUCTIONS. GASEOUS FUEL BURNING PAN MUST BE PERMANENTLY ANCHORED TO THE
FIREBOX. FIREPLACE MUST COMPLY W/. THE CALIFORNIA ENERGY STANDARDS MANDATORY MEASURES.)
12.01 FURNISHINGS
AS SELECTED
22.04 BATHTUB
FREE-STANDING, AS SELECTED (VERIFY LOC'N. OF FIXTURES W/. OWNER)
SCALE: 1/4" = 1'-0"3LONGITUDINAL SECTION
SCALE: 1/4" = 1'-0"1TRANSVERSE SECTION
SCALE: 1/4" = 1'-0"2TRANSVERSE SECTION
PAD SCHEDULE
2'-0" SQ. X 24" DEEP PAD W(4)- # 5 E.W. @ BOTTOMP1
2'-6" SQ. X 24" DEEP PAD W(5)- # 5 E.W. @ BOTTOMP2
3'-0" SQ. X 24" DEEP PAD W(6)- # 5 E.W. @ BOTTOMP3
3'-6" SQ. X 24" DEEP PAD W(6)- # 5 E.W. @ BOTTOMP4
4'-0" SQ. X 24" DEEP PAD W(7)- # 5 E.W. @ TOP & BOTTOMP5
4'-6" SQ. X 24" DEEP PAD W(8)- # 5 E.W. @ TOP & BOTTOMP6
5'-0" SQ. X 24" DEEP PAD W(9)- # 5 E.W. @ TOP & BOTTOMP7
6'-0" SQ. X 24" DEEP PAD W(8)- # 6 E.W. @ TOP & BOTTOMP8
6'-6" SQ. X 24" DEEP PAD W(8)- # 6 E.W. @ TOP & BOTTOMP9
P10 8'-6" SQ. X 24" DEEP PAD W(11)- # 6 E.W. @ TOP & BOTTOM
P11 5'-0" WIDE X 6'-0" LONG X 24" DEEP PAD W/ #5 @ 6" O.C. E.W. @ BOTTOM
P12 7'-6" WIDE X 10'-0" LONG X 24" DEEP PAD W(12)- # 6 E.W. @ BOTTOM
P13 9'-0" WIDE X 10'-0" LONG X 24" DEEP PAD W(9)- # 7 E.W. @ BOTTOM
P14 9'-0" WIDE X 13'-0" LONG X 24" DEEP PAD W/#6 @ 6" O.C. E.W. @ BOTTOM
P15 9'-0" WIDE X 19'-0" LONG X 24" DEEP PAD /W #6 @ 6" O.C. E.W. @ BOTTOM
P16 10'-0" WIDE X 13'-0" LONG X 24" DEEP PAD /W(12)- #7 E.W. @ BOTTOM
List of work requiring
special inspection:
SOILS COMPLIANCE PRIOR TO FOUNDATION INSPECTION
STRUCTURAL CONCRETE OVER 2500 psi
EXPANSION/ EPOXY ANCHORS
STRUCTURAL SHEAR WALLS TYPE NUMBER 2, 3, AND 4.
X
X
X
X
FIELD WELDINGX
HIGH STRENGTH BOLTS (A325)X
ANCHOR BOLT SCHEDULE
5/8" DIAMTETER X 12" ANCHOR BOLTS @ 32" O.C.32
5/8" DIAMTETER X 12" ANCHOR BOLTS @ 16" O.C.16
5/8" DIAMTETER X 12" ANCHOR BOLTS @ 8" O.C.8
3/4" DIAMTETER X 12" ANCHOR BOLTS @ 8" O.C. (MIN 3
A.B.'S)8*
FOUNDATION NOTES
1. ALL CONTINUOUS EXTERIOR FOOTINGS SHALL HAVE 5/8" DIAMETER X 12" A.B.'S
WITH 3" X 3" X 1/4" WASHERS, MIN.7" EMBEDMENT ONTO CONCRETE, AT 48" O.C.
UNLESS NOTED OTHERWISE ON PLANS. ONE ANCHOR BOLT SHOULD BE LOCATED
MAX. 12" AWAY FROM THE END OF THE SILL PLATE. MIN (2) A.B.'S PER SILL PLATE
PER SHEAR PANEL.
2. ALL INTERIOR WALLS SHALL HAVE HILTI-XU 7/32"Ø X 3 1/2" @ 32" O.C. TO BE
INSTALLED WITH ICC NUMBER 2269. ACTUAL SLAB THICKNESS SHALL BE
MINIMUM 3-1/2"
3. ALL HOLDOWNS AND POST ANCHORS SHALL BE INSTALLED ACCORDING TO SIMPSON
STRONG TIE SPECIFICATIONS AND REQUIREMENTS OF ICC REPORT # 2330
AND SHALL BE TIED IN PLACE PRIOR TO FOUNDATION INSPECTION.
4. MIN. CONCRETE WIDTH SHALL BE 8" FOR RECEIVING MPAs. AND HPAHD22s. VERIFY
LOCATIONS OF HOLDOWNS AND ANCHOR BOLTS WITH ROUGH FRAMING TO ASSURE
PROPER AND ACCURATE INSTALLATION.
5. PROVIDE #3X24" DOWEL AT 24" O.C. AND 12" FROM THE CORNER AT ALL CONCRETE
STOOP AND PORCHES.
6. PROVIDE MINIMUM (2) #5 REINFORCING BAR AT TOP AND (2) #5 AT BOTTOM FOR ALL
CONTINUOUS FOOTING IN ADDITION (1) #4 BAR EXTRA FOR ELECTRICAL GROUND.
LOCATION TO BE VERIFIED WITH ELECTRICAL CONTRACTOR.
7. VERIFY MINIMUM FOUNDATION DEPTH, WIDTH,REINFORCING STEEL AND ADDITIONAL
EXPANSIVE SOIL REQUIREMENTS WITH VALID SOILS REPORT AND IF ANY MORE
RESTRICTIVE THE SHALL SUPERSEDE THE ABOVE MINIMUMS.
8. CONCRETE STRENGTH SHALL BE MINIMUM 4,000 PSI, WATER CEMENT RATIO OF .5 AND
TYPE II CEMENT.
9. FOUNDATION DRAWING SHALL REFLECT THE STRUCTURAL REQUIREMENT ONLY.
REFER TO ARCHITECTURAL PLANS FOR DIMENSIONS NOT SHOWN.
ACCURACY OF THE DIMENSIONS AND FINAL FIT OF THE BUILDING SHALL BE
REVIEWED BY THE ARCHITECT AND THE CONTRACTOR PRIOR TO CONSTRUCTION.
10. WAITING PERIOD FOR CONCRETE SLAB-ON-GRADE PRIOR TO START OF
CONSTRUCTION IS AS FOLLOWS:
a. WALK ON SLAB 24 HOURS AFTER CONCRETE HAS BEEN POURED.
b. BEGIN WALL FRAMING 4-5 DAYS AFTER CONCRETE POUR.
c. BEGIN ROOF/FLOOR FRAMING 7-10 DAYS AFTER CONCRETE POUR.
d. DO NOT LOAD ROOF PRIOR TO 14 DAYS AFTER CONCRETE POUR.
11. THE MAXIMUM SOIL BEARING PRESSURE IS 1,000 PSF. FOR MAT FOUNDATION & 1,750 & 2,250 PSF
FOR CONT. FT'G & PAD FOOTING, PER SOILS REPORT #BA249.1, PREPARED BY: EGA CONSULTANTS,
INC. DATED: 11/17/2020.
12. ALL DIMENSIONS SHOWN ON THE PLANS HAVE BEEN DETERMINED BY THE ARCHITECT
13. FASTNERS FOR PRESERVATIVE-TREATED SHALL BE HOT DIPPED ZINC-COATED
GALVANIZED STEEL, SILICON, BRONZE, OR COPPER.
14. SHEAR WALL ANCHOR BOLTS AND HOLDDOWN HARDWARE MUST
BE SECURED IN PLACE PRIOR TO FOUNDATION INSPECTION.
FOUNDATION LEGEND
EXTERIOR FOUNDATION
INTERIOR FOOTING
GRADE BEAM
HARDY FRAME NOTES:
HARDY FRAMES TO BE INSTALLED AT CENTER WIDTH OF GRADE BEAM
ALL REINFORCING STEEL AND TIES FOR HARDY FRAME TO
BE 60 KSI STEEL INCLUDING BARS #3,4,5,6
HFX SPECIAL INSPECTION NOTE:
PER SECTION 1704.1.1,SPECIAL INSPECTION IS REQUIRED FOR HFX ANCHOR PLACEMENT
INCLUDING BOLT WASHER ASSEMBLY,EDGE DISTANCE AND END DISTANCE,SHEAR TIES
AND REINFORCING BARS
HFX STRUCTURAL OBSERVATION NOTE:
IN ACCORDANCE WITH DEPARTEMENT POLICY CBC 1710,STRUCTURAL OBSERVATION IS
REQUIRED FOR HFX ANCHOR PLACEMENT INCLUDING BOLT WASHER ASSEMBLY,EDGE
ISTANCE AND END DISTANCE,SHEAR TIES AND REINFORCING BARS
VERIFICATION AND INSPECTION
1. INSPECTION OF REINFORCING STEEL, INCLUDING PRESTRESSING TENDONS, AND PLACEMENT.
2. INSPECTION OF REINFORCING STEEL WELDING IN ACCORDANCE WITH TABLE 1705.2.2, ITEM 2B.
3. INSPECTION OF ANCHORS CAST IN CONCRETE WHERE ALLOWABLE LOADS HAVE BEEN INCRESED OR WHERE
STRENGTH DESIGN IS USED.
4. INSPECTION OF ANCHORS POST-INSTALLED IN HARDENED CONCRETE MEMBERS.
5. VERIFY USE OF REQUIRED DESIGN MIX.
6. AT THE TIME FRESH CONCRETE IS SAMPLED TO FABRICATE SPECIMENS FOR STRENGTH TESTS, PERFORM
SLUMP AND AIR CONTENT TESTS, AND DETERMINE THE TEMPERATURE OF THE CONCRETE.
7. INSPECTION OF CONCRETE AND SHOTCRETE PLACEMENT FOR PROPER APPLICATION TECHNIQUES.
8. INSPECTION FOR MAINTENANCE OF SPECIFIED CURING TEMPERATURE AND TECHNIQUES.
9. INSPECTION OF PRESTRESSED CONCRETE:
A. APPLICATION OF PRESTRESSING FORCES.
B. GROUTING OF BONDED PRESTRESSING TEN-DONS IN THE SEISMIC FORCE-RESISTING SYSTEM.
10. ERECTION OF PRECAST CONCRETE MEMBERS
11. VERIFICATION OF IN-SITU CONCRETE STRENGTH, PRIOR TO STRESSING OF TENDONS IN POST-TENSIONED
CONCRETE AND PRIOR TO REMOVAL OF SHORES AND FORMS FROM BEAMS AND STRUCTURAL SLABS.
12. INSPECT FORMWORK FOR SHAPE, LOCATION AND DIMENSIONS OF THE CONCRETE MEMBER BEING FORMED.
TABLE 1705.3 REQUIRED VERIFICATION AND INSPECTION OF CONCRETE CONSTRUCTION
__
__
__
__
__
X
X
__
X
X
__
__
__
CONTINUOUS
X
__
X
X
X
__
__
X
__
X
X
X
PERIODIC REFERENCE
STANDARD
ACI 318: 3.5, 7.1-7.7
AWS D1.4
ACI 318: 3.5.2
ACI 318: 8.1.3,
21.2.8
ACI 318: 3.8.6, 8.3.6, 21.2.8ACI 318: CH. 4,
5.2-5.4
ASTMC 172
ASTMC 31
ACI 318: 5.6, 5.8
ACI 318: 5.9,
5.10ACI 318: 5.11-5.13
ACI 318: 18.20
ACI 318: 18.18.4
ACI 318: CH. 16
ACI 318: 6.2
ACI 318: 6.1.1
IBC
REFERENCE
1910.4
__
1908.5, 1909.1
1909.1
1904.2, 1910.2, 1910.3
1910.10
1910.6,
1910.7, 1910.8
19.10.9
__
__
__
__
LOUNGE
GREAT ROOM
KITCHEN
PANTRY
DINING
ENTRY
STAIRS
PWDR.
ELEV.
SAND ROOM
3-CAR GARAGE
15" THK CONC. MAT SLAB
W/ #5 @ 12"O.C. EACH WAY TOP & BOTTOM
F'c = 4,000 PSI
OVER 2" SAND
OVER 15 MIL VAPOR BARRIER MEETING (ASTM 1745)
WITH ALL LAPS SEALED
OVER 4" THICK BASE OF 3/4" GRAVEL
1' - 6"
1' - 6"
1' - 6"
9
D1
1
D1
1
D1
1
D1
1
D1
6
D1
11
D1
9
D11
D11
D1
1
D1
12
D16
D1
10
D1
5
D1
TYP. @
NON-BR'G
WALL
76' - 11"
24" WIDE X 24" DEEP GRADE
BEAM W/ (4) #5 TOP & BOTT. & #4
TIES @ 12" O.C., F'c = 4,000 PSI,
SPECIAL INSPECTION IS
REQUIRED.
P10
P12P5
2
D1
1' - 6"P3
P4
P9
P4
HSS 12X4X1/2STEEL COL.HSS 12X4X1/2STEEL COL.HSS 10X4X1/2STEEL COL.P13
P8
HSS 5X5X1/2STEEL COL.
HS S 5 X5 X1 /2
S T E E L C O L .
11D1
PROPERTY LINE
PROPERTY LINE
PROPERTY LINE
12
D1
15" THK CONC. MAT SLAB
W/ #5 @ 12"O.C. EACH WAY TOP & BOTTOM
F'c = 4,000 PSI
OVER 2" SAND
OVER 15 MIL VAPOR BARRIER MEETING (ASTM 1745)
WITH ALL LAPS SEALED
OVER 4" THICK BASE OF 3/4" GRAVEL6x8 POSTW/
HDU116x8 POSTW/
HDU116x8 POSTW/
HDU116x8 POSTW/
HDU118 8
8
D1
8
D1
8
D1
8
D13X SILL PLATE 3X SILL PLATE
6x6 POSTW/
HDU58
D1
6 x 8 P O S T
W / HD 1 9
6 x 8 P O S T
W / H D1 9
8*3X SILL PLATE4
D1
4
D1 6x8 POSTW/ HDU118
D1
6x8 POSTW/
HDU118
D1
8
3X SILL PLATE HSS 10X4X1/2STEEL COL.
17-A
D1
HSS 10X4X1/2STEEL COL.
17-A
D1
6 x 8 P O S T
W/ C B S Q
HSS 9X5X5/8STEEL COL.18
D1
HSS 10X4X1/2STEEL COL.17-B
D1
6x6 POSTW/ CBSQ
H S S 9 X5 X5 /8
ST EE L C O L .
18
D1
6x6 POSTW/ HDU86x6 POSTW/ HDU86x6 POST
W/ CBSQ
8
3X SILL PLATE 8
D1
8
D16x8 POSTW/ HDU146x8 POSTW/
HDU148
3X SILL PLATE 8
D1
8
D16x10 POSTW/
HDU86x6 POSTW/
HDU88
3X SILL PLATE 8
D18
D1
17-D
D117-G
D1
HSS 8X4X1/2STEEL COL.17-F
D1
3' - 0"30" WIDE X 30" DEEP GRADE
BEAM W/ (6) #5 TOP & BOTT. & #4
TIES @ 12" O.C., F'c = 4,000 PSI,
SPECIAL INSPECTION IS
REQUIRED.
H S S 5 X5 X1 /2
S T E E L C O L .17-L
D1 6x8 POSTW/ HDU146x8 POSTW/ HDU148*
3X SILL PLATE
4
D1 4
D1
2D1
1' - 6"6 x 8 P O S T
W / H D U1 44
D1
6x8 POSTW/ HDU14
4
D1
8*3X SILL PLATE6x8 POSTW/ HDU144
D1
6x8 POSTW/ HDU144
D1
8*
3X SILL
PLATE
17-H
D1
2 -HF X 2 1 x 9
W / 1 -1 /8 H .S .
HA R DY F R A M E7
HFX2
3
HFX1
17-I
D1
6x8 POSTW/ HDU11
6 x 8 P O S T
W / H D U1 1 4
D1
8
D1
8
3X SILL PLATE6x6 POSTW/ HDU8 3
D1
HSS 10X4X1/2STEEL COL.17-C
D1
6 x 6 P O S T
W / H DU8
8
3X SILLPLATE3
D1
P8
P5
P16
P8
P3 P3
P2
P2
P4
P2
17-E
D1
P6
H S S 8 X4 X1 /2
S T E E L C O L .
17-M
D1
HSS 6X4X1/2STEEL COL.
17-K
D1HSS 8X4X1/2STEEL COL.17-J
D1
16
D1
P3
P11
P14
P15
PAD
UNDER
SLAB
1' - 0"1' - 0"1' - 0"H S S 8 X3 X1 /2
S T E E L CO L .
17-N
D1
6x8 POSTW/ HDU5
3
D1 6x6 POSTW/ HDU53
D1
6x6 POSTW/
HDU58
D1
6x8 POSTW/
HDU88
D16x8 POSTW/
HDU88
D1 6x8 POSTW/
HDU88
D16x8 POSTW/ HDU88
D1HSS 8X4X1/2"F.H.
ST.
COL.
17-J
D1
P8
2' - 0"2' - 0"SHEET410 Goddard, Suite # 200Irvine, CA. 92618EMAIL: INFO@FMHENGINEERING.COMTel: 949-245-8000Cell: 310-422-1536OWNERPROJECT LOCATIONNew Custom Home
REVISIONS
1.
PROJECT
S-1FOUNDATION PLANHARVEY
RESIDENCE908 W. OCEANFRONT,NEWPORT BEACH, CA.908 W. OCEANFRONT,NEWPORT BEACH, CA.21-001HARVEY RESIDENCE05-18-2021
1/4" = 1'-0"1 S-1 - FOUNDATION PLAN
SHEET
PROJECT
D-1
16
14
13
9
8
12
11 6
7
4
3
2
1
5101517
21-001 NEWPORT BEACH., CA.HARVEY RESIDENCE908 W. OCEANFRONT,NEWPORT BEACH., CA.410 Goddard, Suite # 200Irvine, CA. 92618Tel: 949-245-8000Cell: 310-422-1536EMAIL: INFO@FMHENGINEERING.COMREVISIONSSHEET TITLEPROJECT LOCATIONFOUNDATION DETAILSPROJECT INFORMATIONPROJECT / TITLE
NEW CUSTOM
HOME
05-18-2021 908 W. OCEANFRONT,EXTERIOR BEARING WALL DETAIL
MAT SLAB PER PLAN
3"3"1'-6"
3"
CLR3"CLR2X STUD WALL
(2) #5 CONT. TOP & BOTT.
E.N.
F.G.
1:1 SEE PLANSLAB REINFORCEMENT
PER PLAN
A.B.'s @ 48" O.C. U.N.O ON PLANS.
W / 7" EMBEDMENT INTO FIRST POUR
2X OR 3X P.T.D.F. SILL PLATE
WITH 5/8" DIAMETERSHEAR
PER
PLAN
#24" MIN.#5 @ 12" O.C. W/ 48"
EMBEDMENT INTO SLAB
PER FOUNDATION PLANS
SLAB UNDERLAYMENT
SEE MINIMUM
FOUNDATION DEPTH
AT HOLDOWN PER
DETAIL 3,4&8/D1 4" MAX.(WHERE OCCURS)
INTERIOR BEARING WALL DETAIL
MAT SLAB PER PLAN
3"3"2:1
(2) #5CONT. BAR TOP. & BOTT.SEE PLAN1'-6"
2X STUD WALL
E.N.
SHEARPER
PLAN
#
2:1
#5 @ 12" O.C. W/ 48" EMBEDMENT
EACH SIDE INTO SLAB
MAT SLAB PER PLAN
3"3"3"3"2:1
(2) #5CONT. BAR TOP. & BOTT.
PER PLAN SEE PLAN1'-6"
2X STUD WALL
E.N.
SHEARPER
PLAN
#2X OR 3X P.T.D.F. SILL PLATE
WITH 5/8" DIAMETER A.B.'s @
48" O.C. U.N.O. ON PLANS. W/
7" EMBEDMENT INTO FIRST
POUR
2:1
#5 @ 12" O.C. W/ 48" EMBEDMENT
EACH SIDE INTO SLAB
SLAB REINF.
PER FOUNDATION PLANS
SLAB UNDERLAYMENT
COLD JOINT
SLAB
SSTB BOLT
ANCHOR TYPE
de
le5"
M
I
N
.
- REFER TO MFR. SPECS. FOR INSTALLATION TO WOOD MEMBER
21"
25"
1 3/4"
1 3/4"
HDU5
HDU8
4X4
4X4
5/8" SSTB24
ANCHOR DIA. AND TYPE
HOLDOWN
SIMPSON
(MIN.)
POST de le MIN DIST.
TO CORNER
- f'c = 2500 psi (U.N.O.)
- SEE PLANS FOR HOLDOWN TYPE
- DEEPEN FOOTING AS REQUIRED TO ACHIEVE le + 3" COVER
- REFER TO MFR. SPECS. FOR INSTALLATION TO WOOD MEMBER
- PROVIDE MIN. #4 BAR, 6'-0" LONG, 3" TO 5" FROM THE TOP OF
THE FOUNDATION. CENTERED AT "HD" OMIT IF BARS EXISTS AT THIS LOCATION
7/8" SSTB28
5"
5"
BASED ON WOOD CAPACITY
5645
6970
12" MIN112" MIN
ALLOWABLE TENSION LOADS(LBS)
25"1 3/4"HDU8 4X6 OR 7/8" SSTB28 5"7870
6X6 11 14"MAX.Le-11 1/4"+3" (COVER)
MIN.
TYP. HOLDOWN INSTALLATION
HDU14 6X6 1" DIA. PAB8 15"23"
THE FOUNDATION. CENTERED AT "HD" OMIT IF BARS EXISTS AT THIS LOCATION
- PROVIDE MIN. #4 BAR, 6'-0" LONG, 3" TO 5" FROM THE TOP OF
- REFER TO MFR. SPECS. FOR INSTALLATION TO WOOD MEMBER
- DEEPEN FOOTING AS REQUIRED TO ACHIEVE (De+ 3")
FOOTING
- SEE PLANS FOR HOLDOWN TYPE
- f'c = 2500 psi (U.N.O.)De1-3/4"
PAB
PER TABLE BELOW
SLAB
dePOST
(MIN.)
SIMPSON
HOLDOWN ANCHOR DIA. AND TYPE
1" DIA. PAB86X6HDU11
HOLDOWN
PER PLAN
F"F"
12"
F
18"
HD19 6X6 1 1/4" DIA. PAB10 16"24"
NON-BR'G WALL
SLAB REINFORCEMENT
PER PLAN
MAT SLAB PER PLAN
HILTI-XU (ICC NUMBER 2269)
7/32" DIA. X 3 1/2"
SHOT PINS @ 32" O.C.
2X P.T.D.F. PLATE WITH
PLACED 6" AND 10"
FROM PLATE ENDS.
AND FIRST 2 PINS
WITH 14 GAGE WASHERS
2X STUDS @ 16" O.C.
MAT SLAB PER PLAN
3"3"PER PLAN
3"
CLR3"CLR1:1 SEE PLANSLAB REINFORCEMENT
PER PLAN
EXTERIOR BEARING WALL DETAIL
#5 @ 12" O.C. W/ 48"
EMBEDMENT INTO SLAB
GRADE BEAM. REINFORCEMENT PER PLAN
PER FOUNDATION PLANS
SLAB UNDERLAYMENT4" MAX.PER PLAN#4 HOOKS @ 12" O.C.
POST PER PLAN
SILL PLATE
SLAB REINFORCEMENT
PER PLAN LeHOLDOWN PER PLAN
A307 STEEL ALLTHREAD PER TABLE
(2) #6 (48" LONG) EACH WAY
DIAGONAL & 3" SQ. X 1/4"
THK. PLATE WASHER @
HOLDOWN ALLTHREAD
HDU5
HDU8
5/8"Ø
HOLDOWN
SIMPSON ALLTHREAD(A307)Le
12"
15"7/8"Ø
MAT SLAB PER PLAN
3" SQ X 0.25" STEEL PLATE WASHER
BTWEEN (2) HEAVY HEX NUTS
MAT SLAB PER PLAN
MAX. UPLIFT
CAPACITY
HDU11 15"1"Ø
6000 LBS
8000 LBS
9500 LBS 8" MIN. TOSILL PLATE,10" MAX.TYP. HOLDOWN INSTALLATION
- REFER TO MFR. SPECS. FOR INSTALLATION TO WOOD MEMBER
21"1 3/4"HDU5 4X4 5/8" SSTB24
ANCHOR DIA. AND TYPE
HOLDOWN
SIMPSON
(MIN.)
POST de le MIN DIST.
TO CORNER
5"
BASED ON WOOD CAPACITY
5645
ALLOWABLE TENSION LOADS(LBS)
25"1 3/4"HDU8 4X6 OR 7/8" SSTB28 5"7870
6X6
MAT SLAB PER PLAN
3"3"1'-6"
3"
CLR3"CLR2X STUD WALL
REINFORCEMENT PER
E.N.8"MIN.F.G.
1:1 SEE PLANSLAB REINFORCEMENT
PER PLAN
SHEAR
PLAN #24" MIN.MAT SLAB REINFORCEMENT
PER DETAIL 1/D1
PER FOUNDATION PLANS
SLAB UNDERLAYMENT4" MAX.de
DETAIL 1/D1le
- f'c = 2500 psi (U.N.O.)
- SEE PLANS FOR HOLDOWN TYPE
- DEEPEN FOOTING AS REQUIRED TO ACHIEVE le + 3" COVER
- REFER TO MFR. SPECS. FOR INSTALLATION TO WOOD MEMBER
- PROVIDE MIN. #4 BAR, 6'-0" LONG, 3" TO 5" FROM THE TOP OF
THE FOUNDATION. CENTERED AT "HD" OMIT IF BARS EXISTS AT THIS LOCATION
24"1 3/4"HDU11 6X8 1" SB1X30 5"
24"1 3/4"HDU14 6X8 1" SB1X30 5"
11,175
14,445
POST CONNECTION DETAIL
MAT SLAB PER PLAN
3"3"1'-6"
3"
CLR3"CLR2X STUD WALL
(2) #5 CONT.
E.N.8"MIN.F.G.
1:1 SEE PLANSLAB REINFORCEMENT
PER PLAN
EXTERIOR GARAGE DETAIL
A.B.'s @ 48" O.C. U.N.O ON PLANS.
W / 7" EMBEDMENT INTO FIRST POUR
2X OR 3X P.T.D.F. SILL PLATE
WITH 5/8" DIAMETERSHEAR
PER
PLAN
#24" MIN.PERARCH#5 @ 12" O.C. W/ 48"
EMBEDMENT INTO SLAB
PER FOUNDATION PLANS
SLAB UNDERLAYMENT
SEE MINIMUM
FOUNDATION DEPTH
AT HOLDOWN PER
DETAIL 3 &4/D1 6" MIN.4" MAX.8"
(1) #5 CONT.3"A.B.'s @ 16" O.C. U.N.O.
3X P.T.D.F. SILL PLATE
WITH 5/8"Ø X 12"
2'-0" TYP.
#5 @ 12" O.C. E.W.
#5 @ 12" O.C.3" CLR.TYP.10" CONC. WALLELEVATOR PIT.12"PER MANUFACTURER2'-6" MAX.10" CONC. WALL
ELEVATOR PIT DETAIL
10"10"
MAT SLAB PER PLAN
3"3"1'-6"
3"
CLR
2X STUD WALL
(2) #5 CONT.
E.N.
1:1 SEE PLANSLAB REINFORCEMENT
PER PLAN
A.B.'s @ 48" O.C. U.N.O ON PLANS.
W / 7" EMBEDMENT INTO FIRST POUR
2X OR 3X P.T.D.F. SILL PLATE
WITH 5/8" DIAMETERSHEAR
PER
PLAN #PERARCHMAT SLAB PER PLAN
3"3"1:1SEE PLAN#5 @ 12" O.C. W/ 48"
EMBEDMENT INTO SLAB
48"
48"6" MIN.4" MAX.4" MAX.(WHERE OCCURS)
#5 @ 12" O.C. W/ 48"
EMBEDMENT INTO SLAB
SLAB REINFORCEMENT
PER PLAN
(2) #5 CONT.
OR HARDY FRAMEWHERE OCCURS
1'-6"
HOUSE TO GARAGE
(1) #5 CONT.
8"3"18" MAXSTEP AT CONCRETE SLAB
W/ 18" EMBEDMENT
FOR DBL POUR COND.
#5 DOWELS @ 24" O.C.
INTO EACH WAY
#5 CONTINUOUS BAR
#5 CONTINUOUS BAR
SLAB REINF. PER PLAN
MAT SLAB PER PLAN
3"3"1'-6"
3"
CLR3"CLR(2) #5 CONT.
1:1 SEE PLANSLAB REINFORCEMENT
PER PLAN
#5 @ 12" O.C. W/ 48" EMBEDMENT
INTO SLAB
EXTERIOR BEARING WALL DETAIL 4" MAX.3"
CLR
(TYP)
PER FOUNDATION PLANS
SLAB UNDERLAYMENT24" MIN.40 D OR24" MIN.40 D OR24" MIN.40 D OR
24" MIN.
ALTERNATE
CORNER PIECE (
BAR BENDS
OMITTED).
FOOTING
REINFORMENT.
FOUNDATION PER
PLANS
REINFORCING REBAR @ CORNERS
R
R 8(d)8(d)
°90 BEND °180 BENDBEND
4(d)
2 1/2" MIN.12dWIRE TIE END
48(d) * IN CONCRETE
48(d) MASONRY (U.N.O.)
LAP SPLICE
R = 3(d) FOR #3 THRU #8
R = 4(d) FOR #9 THRU #11
R = 5(d) FOR #12 THRU #18
TYP. REINFORCING DETAILS
* INCREASE LENGTH BY 30%
FOR TOP BARS (HORIZONTAL
BARS SO PLACED THAT MORE
THAN 12 INCHES OF FRESH
CONCRETE IS CAST IN THE
MEMBER BELOW, EXCLUDE
WALLS)
CLOSED TIE OR HOOP
STIRRUP DETAILINGDIMENSION4
"
M
IN
.
O
R
6(
d
)
M
I
N
.DETAILINGDIMENSION4" M
IN
.
OR
6
(
d
)
M
IN
.
CROSSTIE
D = 4(d) FOR #3 THRU #5
D = 6(d) FOR #6 THRU #8
NOTES:
- PUT CROSSTIE W/ EACH
STIRRUP ALT. 135 BENDS°
- ALL BENDS SHALL BE
MADE COLD
D D
12(d) FOR #6 THRU #86(d) FOR #5 & SMALLER> 3" MIN.6(d)> 3" MIN.1/2" THK. BASE PLAT W/ (2)-3
4"Ø
A.B'S.
STEEL TUBE PER PLAN
MAT SLAB PER PLAN 12"3/8"
SLAB REINFORCEMENT
PER PLAN 3"SEE PLAN3"STRINGERS TO FOOTING CONNE.
#5 @ 12" O.C.SEE PLANSEE PLAN
1" DRYPACK
3" MIN.STEEL COLUMN
PAD PER PLAN 18"3/8"
PER PLAN
W/ 24" EMBEDMENT
MAT SLAB
PER PLAN
INTO MAT SLAB EACH SIDE
BASE PLATE PER
CONDITION A-N
OPTION A
MAT SLAB
SEE PLANSEE PLAN
1" DRYPACK
3" MIN.STEEL COLUMN
PAD PER PLAN 18"3/8"
PER PLAN
PER PLAN
BASE PLATE PER
CONDITION A-N
#5 @ 12" O.C.
W/ 24" EMBEDMENT
INTO MAT SLAB EACH SIDE
OPTION B
STEEL COLUMN DETAIL
20" L. X 10" W. X 1"
THK. BASE PL W/ (5)
-3/4"Ø X 18" LONG
AB'S10"20"3"3"3"
10"3"3"
3/8"
A B
20" L. X 10" W. X 1"
THK. BASE PL W/ (5)
-3/4"Ø X 18" LONG
AB'S
10"20"3"3"3"10"3"3"3/8"
C
20" L. X 10" W. X 1"
THK. BASE PL W/ (5)
-3/4"Ø X 18" LONG
AB'S
10"20"3"3"3"10"3"3"3/8"20" L. X 10" W. X 1"
THK. BASE PL W/ (5)
-3/4"Ø X 18" LONG
AB'S
10"20"3"3"3"
10"3"3"
3/8"
D
22" L. X 10" W. X 1"
THK. BASE PL W/ (5)
-3/4"Ø X 18" LONG
AB'S10"22"3"3"3"
12"3"3"
3/8"
E
18" L. X 10" W. X 1"
THK. BASE PL W/ (5)
-3/4"Ø X 18" LONG
AB'S
10"18"3"3"3"
8"3"3"
3/8"
F
22" L. X 10" W. X 1"
THK. BASE PL W/ (5)
-3/4"Ø X 18" LONG
AB'S
10"22"3"3"3"
12"3"3"
3/8"
G
3/8"
15" L. X 11" W. X 1"
THK. BASE PL W/ (5)
-3/4"Ø X 18" LONG
AB'S
11"15"3"3"3"5"3"3"H
9" L. X 11" W. X 1"
THK. BASE PL W/ (5)
-3/4"Ø X 18" LONG
AB'S
11"9"3"3"3"5"3"3"3"5"
3/8"
I
18" L. X 10" W. X 1"
THK. BASE PL W/ (5)
-3/4"Ø X 18" LONG
AB'S10"18"3"3"3"
8"3"3"
3/8"
J
K
14"
4"16"3"2"3"3/8"
16" L. X 14" W. X
3/4" THK. BASE PL
W/ (4) -3/4"Ø X 18"
LONG AB'S6"5"5"5"3"2"15"15"3"3/8"
L
15" L. X 15" W. X 3/4"
THK. BASE PL W/ (4)
-3/4"Ø X 18" LONG
AB'S
14" L. X 10" W. X 1"
THK. BASE PL W/ (5)
-3/4"Ø X 18" LONG
AB'S10"14"3"3"3"
8"3"3"
3"4"3/8"
M
3/8"
18" L. X 10" W. X 1"
THK. BASE PL W/ (5)
-3/4"Ø X 18" LONG
AB'S
10"18"3"3"3"8"3"3"N
8" MIN.
1
2
GRADE BEAM @ COLUMN FOOTING
GRADE BEAM PER PLAN
SEE PLANSEE PLAN
WITH 3/4" Ø A.B.
MIN. 30" L X 30"W X 1 1/2" THK
1" DRYPACKd
3" MIN.STEEL COLUMN
PER PLAN
2'-0" MIN.2d
"d": SEE PLAN
#4 TIES @ 3.5" O.C.,FIRST
TIE MUST BE 2" FROM
COLUMN BASE
#4 TIES @ 3.5"
O.C.,FIRST TIE MUST BE
2" FROM COLUMN
BASE
1/2"CJP2"2"1/2"
30" L. X 30" W. X
1 1/2" THK. BASE
PL W/ (10) -3/4"Ø
X 18" LONG AB'S2'-6"2'-6"
18