HomeMy WebLinkAboutX2021-0437 - Alternative Material & MethodsJ
p
0
1 i
C f
Pi
I.I s l
l
�
y
co
F Lo
�1
co
W co
o
@
ca z o
Ei o-v
z >
0
aA"D,)
U
0
W�j
O @
>Am9
O'o
— 3:
z
U
U
o °
U v
O
O
'
C
O
1
Y
y
o
W °
U d
�
c
�
►�
# U y
c
00 3@�
CL o�
@o
OaU-
E 0 0 LL U> Z LL
COaN
i
N C7 �
�
N
Z ? W LL
W❑UV
0
O
W
N
KNQ
awn.
Q
2
Q
d
cai
°-9
ao>
m a
ZF❑ °
a o.CL
r
QOV¢
<ot-
EY
U
U.0W w
Z N
W0
v C
co
rL wWm
Um
QLL
y 01
K O o
0.
a o 12
O(D
Z
H= m
i Q
LU
N J
wLLI ~ @
w
O2�
OTC
LU
02ooU
W
lL
11
a
.I
d
0
L
Q
a
R
Ul
LM
N
0
c
a
.I
0
C @
@ w
w w
❑ ❑
0 0
d �
00
1%
T"
N
d
r
d
wl
p
V
■
O
J
G
C
0
0
a
N
September 21, 2021
Subject: 36 Royal St. George Rd.
Newport Beach, CA 92660
Structural Revision to slab on grade in family room
To Whom It May Concern:
Structural slab on grade as follows is structurally adequate.
4" Thick concrete slab with #4 @ 18" o.c. over
--Be� CCw ?,ek Ct pit ��Stcr�
Moisture Barrier
Sand 2"
Moisture Barrier
Existing Grade/Soil
Sincerely,
Gonzalez Structural Engineering
Jorge Gonzalez, P.E.
Gonzalez Structural Engineering
661.709.1416
jgonzalez5476@gmail.com
J . �
ll
CoolFnas & waterproofing
DESCRIPTION
CCW MiraCLAY has a uniform layer of sodium bento-
nite clay that is sandwiched between a durable punc-
ture resistant nonwoven polypropylene fabric and a high
tensile strength woven polypropylene fabric and then
needlepunched together with thousands of high strength
denier yarns. These fibers are then thermally fused to
the polypropylene in a patented InfrabondTM procedure
that locks the sodium bentonite into place.
TYPICAL USES
CCW MiraCLAY is designed for waterproofing below
grade structural slabs as well as construction methods
incorporating lagging, concrete caisson or shotcrete re-
tention walls. CCW MiraCLAY is also very effective in
rehab waterproofing and zero clearance property line
construction.
ADVANTAGES
The CCW MiraCLAY waterproofing membrane has
the ability to heal itself if ripped or punctured.
• 1n a hydrated state the bentonite-clayhas tremen-
dous impermeability and excellent resistance to
chemicals (i.e., acids, bases and hydrocarbons).
• The CCW MiraCLAY has the ability to expand and
seal cracks in concrete.
INSTALLATION
UNDERSLAB APPLICATIONS
CCW MiraCLAY is designed for use under reinforced
concrete slabs 4" (100 mm) thick or greater on a com-
pacted earth/gravel substrate. If installed over a mud
slab, CCW MiraCLAY requires a minimum 5" (150 mm)
thick reinforced concrete slab.
For contaminated site water conditions, as determined
by a site water analysis, CCW MiraCLAY EF should be
used.
When hydrostatic conditions exist, CCW MiraCLAY
should be installed under footings and grade beams as
shown in CCW MiraCLAY details.
SUBSTRATE PREPARATION
NOTE: Do not begin construction in work areas where
there is standing water or in situations which may cause
the CCW MiraCLAY to prematurly hydrate.
Before installing CCW MiraCLAY, the substrate must
be properly prepared. Substrate may be concrete, earth,
sand, pea gravel or crushed stone. Earth and sand sub-
strates should be compacted to a minimum 85% Modi-
fied Proctor density. Crushed stone should not be larger
than 3/4" (18 mm) in size. Substrate should be smooth
and uniform without sharp projections or pockets. Com-
plete all required elevator pit, sump pit and grade beam
and piling work before installing CCW MiraCLAY under
main slab area
- —INSTALLATION
Install CCW MiraCLAY over the properly prepared sub-
strate with the non -woven geotextile side up. The CCW
MiraCLAY product name is printed on the non -woven
geotextile side. Overlap adjoining edges a minimum of
4" (100 mm); stagger sheet ends a minimum of 24" (600
mm); and nail or staple edges together as required to
Prevent any displacement during concrete placement.
CCW MiraCLAY Granules may also be placed in the
seam for additional waterproofing performance.
When the slab is poured in sections, CCW MiraCLAY
should extend a minimum 12" (300 mm) beyond the
slab edge. When the installation reaches the outer edge
TECHNICAL DATA
Property
Test Method
Unit
Bentonite Content
Permeability4
@ 12% moisture content
Ib/ft (kg/m)
Typical Value
1.0
Grab Tensile Strength
9
ASTM D 5084
ASTM D 4632
cm/sec, max
(4.88)
5 X 10 s
Grab Elongations
ASTM D 4632
lbs. (N )
95
Internal Shear Strengths
ASTM D 5321
%�
50
Swell Index
ASTM D 5890
Psf (kPa)
0 (
5024)
Fluid Loss
ASTM D 5891
29 (24m1) min.
Low Temperature Flexibility
ASTM D 1970
ml
18 ml max.
Peel Strength'
ASTM D 4632
@ 25°F (-32°C)
unaffected
'At 12% moisture content. Equates to U,Og IDS
direction. 'Modified to use a 4 inch wide grip.
Ibs (N) 15 (66)
at 0%. when indexed to a 12% moisture content. 'Measure at maximum peak, in the weakest principle
Measureu
The maximum peak of five specimens
stress and 2 psi head. 'Typical peak value or
averaged. Tap water 5 psi
specimen hydrated for 25hr, and sheared
maximum effective confining
under a 200 Psf normal stress.
of'the slab, continue CCW MiraCLAY up and out of the
form a minimum of 12" (300 mm). At the corner, CCW
MiraCLAY should remain in contact with the substrate
and inside the surface of the concrete form. When the
form is removed, the CCW MiraCLAY outside the form
should be positioned and fastened onto the footing or
vertical wall. Overlay the CCW MiraCLAY a minimum of
6" (150 mm) with the succeeding vertical waterproofing
membrane.
At property line retaining walls, such as soldier pile or
lagging, continue the underslab CCW MiraCLAY appli-
cation up the retaining wall a minimum 12" (300 mm)
above the top edge of the slab or footing and secure.
Overlap the vertical CCW MiraCLAY waterproofing mem-
brane by a minimum of 6" (150 mm) or a minimum of
12" (300 mm) under hydrostatic head conditions.
PROPERTY LINE OR LAGGING APPLICATION
SUBSTRATE PREPARATION
Gaps between the wood lagging greater than 1" (25 mm)
must be filled with cementitious grout. In areas with
large gaps (1" to 5" / 25mm to 125mm) between lag-
ging, install plywood to provide a uniform substrate.
Where drainage issues may arise, install CCW
MiraDRAIN to provide a uniform substrate as well as to
facilitate drainage.
INSTALLATION
Install CCW MiraCLAY with the non -woven side facing
the installer. The CCW MiraCLAY product name is
printed on the non -woven geotextile side. Secure the
COW MiraCLAY-into-position with fasteners and-V (25
mm) washers. Use the appropriate fasteners for the
type of substrate used to receive the CCW MlraCLAY.
Install succeeding courses of CCW MiraCLAY by over-
lapping the previous course a minimum of 4" (100 mm).
Stagger the seams a minimum of 24" (600 mm). Install
in shingle fashion so that the upper roll of CCW MiraCLAY
is overlaps the lower roll. Fasten membrane once every
2' (60 cm) to 3' (90 cm) on seams or as required to
prevent blousing.
At grade line, after the wall has been poured, terminate
CCW MiraCLAY with a rigid termination bar or fasten 12"
(300 mm) on center. Embed the top edge of CCW
MiraCLAY and termination bar with a thick bead of CCW
MiraCLAY Mastic 2" (50 mm) wide by 1/2" (12 mm) thick.
STANDARD FOUNDATION WALLS
SUBSTRATE PREPARATION
The substrate must be properly prepared to receive the
CCW MiraCLAY waterproofing membrane. All honey-
combs, form -tie cavities and indentations should be filled
With CCW MiraCLAY Mastic or filled with latex Portland
Cement. Substrate must be smooth and uniform re-
moving any protrusions over 1/2" (12mm) from the sur-
face. Footings must be free of soil, rocks or debris to
provide a suitable substrate to receive the CCW
MiraCLAY waterproofing membrane.
INSTALLATION
The CCW MiraCLAY waterproofing membrane should
be installed with the non -woven side facing the applica-
tor. CCW MiraCLAY product name is printed on the non-
woven geotextile side. Create a cant at any vertical to
horizontal transition by applying a 1.5" (39 mm) to 2"
(50mm) of CCW MiraCLAY Granules along that junc-
tion. At the base of the foundation wall where the verti-
cal wall meets the horizontal footing, install a stripping
Ply of CCW MiraCLAY out onto the horizontal plane and
up the vertical wall a minimum of 6" (300 mm). Install
the adjacent rolls of CCW MiraCLAY in a horizontal
manner extending out onto the footing a minimum of
24" (600mm). Fasten the CCW MiraCLAY in place with
concrete fasteners and 1" (25 mm) washers. Install suc-
ceeding courses of CCW MiraCLAY by overlapping the
previous course a minimum of 4" (100 mm). Stagger
the seams a minimum of 12" (300 mm), Install in shingle
fashion so that the upper roll of CCW MiraCLAY is over-
laps the lower roll. Fasten membrane once every 2' "(60
cm) to 3' (90 cm) on seams or as required to prevent
blousing. At grade line, terminate CCW MiraCLAY with
a rigid termination bar or fasten 12" (300 mm) on center.
Embed the top edge of CCW MiraCLAY and termina-
tion bar with a thick bead of CCW MiraCLAY mastic 2"
(50 mm) wide by 1/2" (12 mm) thick.
DETAIL REQUIREMENTS
For standard installation details, follow the CCW
MiraCLAY details drawings. For non-standard installa-
tion instructions contact your local Carlisle Coatings &
-Waterproofing representative. - ----
RECOMMENDATIONS
Carlisle Coatings & Waterproofing recommends the use
Of CCW MiraDRAIN, a geocomposite sheet drain, to
facilitate the removal of water away from the structure.
The CCW MiraCLAY and CCW MiraDRAIN waterproof-
ing and drainage system provides maximum protection
against water penetration.
LIMITED WARRANTY
CARLISLE COATINGS & WATERPROOFING INCORPORATED (CARLISLE) warrants
this product to be free of defects in workmanship and materials
only at the time of shipment from our factory. If any CARLISLE mate-
rials prove to contain manufacturing defects that substantially ef.
fect their performance, CARLISLE will, at its option, replace the mate-
rials or refund its purchase price.
This limited warranty is the only warranty extended by CARLISLE
with respect to its materials. There are no other warranties, in-
cluding the implied warranties of merchantability and fitness for a
particular purpose. CARLISLE specifically disclaims liability for any
incidental, consequential, or other damages, including but not lim-
ited to, loss of profits or damages to a structure or its contents,
arising under any theory of law whatsoever.
The dollar value of CARLISLE s liability and buyer's remedy under this
limited warranty shall not exceed the purchase price of the CARL-
ISLE material in question.
Carlisle Coatings & Waterproofing Incorporated
900 Hensley Lane
Carlisle is a trademark of Carlisle Corporation Wylie, Texas 75098
2002 Carlisle Corporation
CCW MireCLAY 02/03 to coann e a w Toll Free: (800) 527-7092
Ca aterprooFlna
Website: www.carlisle-ccw.com
Chiose, Stefan
From:
J P Ruiz <almagroup54@icloud.comn
Sent:
December 08, 2021 4:13 PM
To:
Chiose, Stefan
Cc:
Jaime Ruiz
Subject:
36 Royal Saint George
[EXTERNAL EMAIL] DO NOT CLICK links or attachments unless you recognize the sender and know the content is safe.
Stefan,
Per your request I'm responding to your questions and proving you with photos of the area in question, which
is 24'x19x 5" approximately 456 Sq ft. As well as floor plan indicating location within scope of work. As denoted by the
engineer in his cover letter, submitted in original request for review you can see the size and spacing of rebar, as well as
multiple vapor barriers, sand and use of CCW Miraclay system.
I hope that this helps.
Thank you,
Jaime Ruiz
949.874.5363