HomeMy WebLinkAboutF2022-0226 - Alternative Material & Methods�EWPo4? , CITY OF NEWPORT BEACH & e n' COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION 1 ZOZZJv� V " ,iz`p 100 Civic Center Drive I P.O. Box 1768 1 Newport Beach, CA 92658-8915 www.newportbeactica.gov 1 (949) 644-3200 CASE NO.: REQUEST FOR MODIFICATION TO PROVISIONS OF TITLE 9 (FIRE CODE) OR TITLE 15 (BUILDING CODE) OF THE NEWPORT BEACH MUNICIPAL CODE (See Reverse for Basis for Approval) (Fee $291) ❑X REQUEST FOR ALTERNATE MATERIAL OR METHOD OF CONSTRUCTION (See Reverse for Basis for Approval) (Fee $291) For above requests, complete Sections 9, 2 & 3 below by printing in ink or typing. JOB ADDRESS: SITE ADDRESS: 2350 Ford Road owner Irvine Ranch Water District Address 15600 Sand Canyon Avenue Irvine. CA zip 92620 Daytime Phone ( 949 ) 453-5675 MA III FOR STAFF USE ONLY III Plan Check # t1 Ul' 4VL2. # of Stories Occupancy Classification V Use of Building ' ,i # of Units Project Status Construction Type, Verified by No of Items Fee due �I 1 DISTRIBUTION: ❑ Owner ❑ Plan Check Petitioner ❑ Inspector Fire ❑ Other Petitioner Daytime Replace existing two 3,000 gallon sodium hypochlorite tanks and pumps with two new 3,000 gallon tanks and um s as art of a tar er ro ect to install a filtrations stem located in a new buildingat a recycled water reservoir. A temporary sodium hypochlorite system will operate during replacement. 3 JUSTIFICATION/FINDINGS OF EQUIVALENCY: CODE SECTIONS: The total sodium h ochlorite storage exceeds the allowable storage volume Table 500rnia Fire Code (CFC) 5003.1.4, YP g g Table 5003.11 (4) Petition. s Position Design Engineer of Record Signature CA Professional Lic. # RCE 48451 Date: April 18, 2022 Lames A. Meyerh ter FOR STAFF USE ONLY DEPARTMENT ACTION: In accordance with: KCBC 104.11/CFC 104.9_ [1 CBC 104.10/CFC 104.8 (Alternate materials & methods) (CBC Modification) Feq!uest urrence from Fire Code Official is required. Approved ❑ Disapproved ❑ Written Comments Attached (DOES) (DOES NOT) lessen any Are protection requirements. if ❑ Request (DOES) (DOES NOT) lessen the structural integrity The Request is: ❑ Granted ❑ Denied (see reverse for appeal information) ❑ Granted (Ratification required) Conditions of Approval: Signature Position Date Print Name APPEAL OF DIVISION ACTION TO THE BUILDING BOARD OF APPEALS (See Reverse) (Signature, statement of owner or applicant, statement of reasons for appeal and filing fees are required.) CASHIER RECEIPT NUMBER: Form \mGdlf 07/01/21