HomeMy WebLinkAboutX2021-1661 - Alternative Material & Methods (2)SIMPSON STRONG WALL FOUNDATION SCHEDULE SSW ANCHORAGE LENGTH (FT) WIDTH (FT) THICKNESS (IN) LONGITUDINAL BARS TR4NSYERSE BARS TOP (5) M6 TOP SSWISxio SSWA51 STD 9'-0' 4'-0' 18' (4) M6 BOTT. (5) "6 BOTT. I 1 f, TYP. FU�> C t TYP. N C - T••,. , (N)CL � I (N) B TH SHEAR WALL SCHEDULE NUMBER ALLOWABLE SHEAR SILL PLATE TO BLOCKING TO PLATE MUD SILL TYPE MATERIAL DESCRIPTION OF SIDES FORCE (PLF) BLOCKING CONNECTION CONNECTION TO FOUNDATION REMARKS 15/32" APA STRUCTURE —1 3/8" 0 LAG —SCREW A35 @ 24" O.C. A.B. @ 48" O.C. 1 W/1Od COMMON NAIL @ 6/6/12 SINGLE 340 @ 12" O.C. x 5" MIN. EMBED. 15/32" APA STRUCTURE —1 3/8" 0 LAG —SCREW A35 @ 14" O.C. 5/8' A.B. @ 32" O.C. 3X SILL PL. 2 W/1Gd COMMON NAIL @ 4/4/12 SINGLE 510 @ 8' O.C. x 5" MIN. EMBED. 15/32" APA STRUCTURE —1 3/8" 0 LAG —SCREW A35 @ 10" O.C. 5/6" A.B. @ 24" O.C. 3X SILL PL. 3 W/1Od COMMON NAIL @ 3/3/12 SINGLE 665 @ 6" O.C. x 5' MIN. EMBED. 15/32" APA STRUCTURE —1 3/8" 0 LAG —SCREW A35 @ 8" O.C. %8' A.B. @ 16" O.C. 3X SILL PL. 4 W/1Od COMMON NAIL @ 2/2/12 SINGLE 870 @ 4.5" O.C. x 5" MIN. EMBED. 15/32" APA STRUCTURE —1 1/2" 0 LAG —SCREW A35 @ 5" O.C. 5/8' A.B. @ 12' O.C. 3X SILL PL., PREDRILLED 5 W/1Od COMMON NAIL @ 3/3/12 BOTH SIDES 1330 @ 5" O.C. x 5" MIN. EMBED. (2)-2X BLK'G OR 0 BLK'G iJ I I 4" THICK CONC. SLAB W. #4 BARS @ 1 E O.C. E.W. @ MID-DEPTH(U.N.O.) OVER 10 MIL MOISTURE BARRIER OVER 4" LAYER 0 7 :11 1/2" OR LARGER DIAMETER GRAVEL OVER NATURAL FIRM SOIL I(E) GARAGE 1 TYP. FD1 I (N) BEDROOM 5 w.. EG E S: • � • �• 7 • �9 I [1 G _ 11(N)LAUNDRY I �-1 4 N yr i FD2 .:.v J !VING 15 FD2 L— -- oc ci II TYp. $ a FD1 ( I ® II NS II II FRONT c,FS6PGIC 14 �11 II "qR J rm I Pt Pt 0 Y oI W oI J z z COAT STOR.— O (E) BATH a •J L'J — — —_ -- (qV GHT I I PANTRY REF. I; ---_-- LINE --(N-- ABOVE —_ —_ I 1AC — _ � - i• '--Y"' -ate.`, \ O _LAB 10 E. CONC. SLAB W. RED GUARD MOISTURE MEMBRANE ESR ICC #1413 Iz IJ 7 —FD1 (N) PATIO (N B ROOM 1AA j EGRESS (E) GARAGE (E) GARAGE III rT I I I I WG ---- 1Z 1Y II (E) CONCRETE SLAB I (N ) BATH 1X I INFILL 1N _ — 1V - qI— It COAT/ STOR.- W I, P 11 -- 1R .. 1P (E) BATH e (N) LAUNDRY _I____, r -E---i I I 1W I y ®'- --a. --- -L •J J t r—.-- k1 (NI SA9Y GHT —� L _ _ _ 1 — \ (N) SKKYYVIGHT AW UP I I 1Q�_ I I `- REF. `--- ---- I 10 REF. I I I f W SASVIGiT (N) SABV GHT I I (Nl S��IGHT 9 I i LIVING I LIVING { KITCHEN KITCHEN, KITCHEN ENTRY ENTR ---- ENTRY --- -I --- I I I I —J A -- � q O ���'�� I (E) DECK (E) DECK Fic(E) DEC l STRUCTURAL NOTES (E) 12" WIDE X 24" DEEP CONCRETE ------------ FOOTING (N)1-STORY 15" WIDE X 24" MIN. DEEI CONCRETE FOOTING w/(2)-#4 T.&B. CONTRACTOR NOTE: • CONTRACTOR TO VERIFY ALL PLACES MARKED WITH "V.LF." AND EXISTING FRAMING/CONDITIONS AND NOTIFY THE ENGINEER OF ANY DISCREPANCIES IMMEDIATELY PRIOR TO COMMENCING ANY WORK. • IF SITE CONDITION OTHER THAN PLAN, CONTRACTOR NEED REPLACE THE EXISTING MEMBER WITH SIZE MARKED ON PLAN OR NOTIFY THE ENGINEER FOR DIMENSIONS NOT SHOWN SEE ARCHITECTURAL DRAWINGS. (VERIFY ALL DIMENSION WITH ARCHITECTURAL PLANS) ADDITIONAL NOTES - 5/8" dio. A.B. (R.H., EPDXY BOLTS) @ 48" O.C. TYP. U.O.N. FOR SH. W. A.B.'S SEE G.N. SHEET, SH. WALL SCHEDULE - NAILS IN PRESSURE TREATED WOOD SILL PLATES SHALL BE HOT DIPPED GALVANIZED, STAINLESS STEEL, SILICON BRONZE OR COPPER. - ALL HOLD-DOWN CONNECTIONS SHALL BE TIGHTENED JUST PRIOR TO ENCLOSURE. - EXCAVATIONS SHALL BE MADE IN COMPLIANCE W/CAL/OSHA REGULATIONS. - CONTINUOUS INSPECTION BY A LICENSED DEPUTY INSPECTOR IS REQUIRED FOR ALL EPDXY WORKS AND FOR CONCRETE WITH f'c>2500 PSI. 4" THK. CONCRETE SLAB ON GRADE W/ #4 BARS @ 16" O.C. E.W.CENTERED PER CITY REQUEST, A 4-INCH THICK BASE OF Y2 INCH OR LARGER CLEAN AGGREGATE SHALL BE PROVIDED FOR THE PROPOSED SLAB ON GRADE CONSTRUCTION. A MOISTURE BARRIER SHALL BE PROVIDED IN DIRECT CONTACT WITH CONCRETE FOR THE PROPOSED SLAB ON GRADE CONSTRUCTION. CARE SHALL BE EXERCISED TO AVOID DAMAGE OF MOISTURE BARRIER DURING CONSTRUCTION. ADDITIONAL NOTES 1. ALL THE EXISTING STRUCTURAL ITEMS INCLUDE BUT NOT LIMITED TO ROOF MEMBERS, WALL MEMBERS, HOEDOWN, AND CONNECTIONS, ETC. WHICH DID NOT SHOW /MENTIONED ON PLAN SHOULD BE REMAINED. IT IS THE SOLE RESPONSIBILITY OF CONTRACTOR AND HAS NOT BEEN TAKEN INTO CONSIDERATION BY STRUCTURAL ENGINEER. 2. THE DESIGN, ADEQUACY, AND OVERALL SAFETY OF ANY ERECTION BRACING, SHORING, TEMPORARY SUPPORTS, ETC. IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND HAS NOT BEEN TAKEN INTO CONSIDERATION BY THE STRUCTURAL ENGINEER. 3. OBSERVATION VISITS TO THE SITE BY STRUCTURAL ENGINEER ONLY CONSTITUTE INSPECTION OF ALL THE NEW MEMBERS AND CONNECTIONS ON PLANS. 0 PAD FOOTING SCHEDULE 8 2'-0" SQ.X12" DEEP FTG. W/(3)-#4 E.W. SYMBOLS & LEGENDS ® 04 COLUMN PER PLAN U.N.O. SPAN AND DIRECTION OF JOIST FRAMING MEMBER PER PLAN SHEAR PANEL NUMBER, MIN. LENGTH NOTED, REFER TO Q "SHEAR WALL SCHEDULE" ON L_ S-0 FOR MORE INFRO (LENGTH IS FROM CENTER OF POST TO CENTER OF POST) DETAIL NUMBER DETAIL SHEET NUMBER CONC, FT'G EDGE (N) PAD FIG. SIZE PER TABLE POST OR POINT LOAD ABOVE Structural Design by: W.H. CONSULTANT 8 WHATNEY, SUITE 100, fBVINE, CA 92618 (949)-229-3357 info®whengineeringgroup.com n� S3 0 Yy—` v �c No.C88467 Exp.03-31- �CIVIV Lo N CD N U � QCC G � J Q W 0 W Z (n O "t W O U REVISIONS ® 1ST PC— 07.28.2021 Q 2ND PC— 09.08.2021 SITE REVISION 12.07.21 SITE REVISION 1.18.22 ASITE REVISION 3.7.22 Title: FOUNDATION PLAN Date: 06-01-2021 Scale: PER PLAN Drawn By. L.J. Job. 21165 Sheet: S.1 X��ZI-I19191 —Of —Sheets SHEAR MAT'L WHERE OCCURS N GALVANIZED SHEET 2x STUD WALL SMETAL CAP 3'x3'xl/4" THICK SLOT'D a 2% SLOPE STEEL WASHER PLATES a PER A.B. f vzr, ° 6' CONIC. WALL W/ 05 0 16' E.W. g 4. /\/\\ X n \//\//\ \ BITUMINOUS WATERPROOFING Q ° j W/ GALVANIZED SHEET \\\% METAL FLASHING ON TOP ° FRENCH DRAIN ° (3) 04 BARS TOP EXTERIOR FOOTING RETAINING WALL 116 WOOD WALL SEE PLAN # SHEAR MAT'L A.B., PER PLAN SEE PLAN 4x8 PT LEDGER W/ HU 2x I" IUDSILL HANGER W/ 3/4'0 BOLTS �@ 16' O.G. U.O.N. QEN. STAGGERED (l)-ADDIT. GONTIN. FLOOR SHEATHING `=' "5 BAR a LEDGER PER PLAN 290 SLOPE BOLT d PA. a �� m FLR. SHT'G (SEE PLAN) 2x F/J (SEE PLAN) SIMPSON PE (SEE PLAN) � SLAB SEE PLAN SIMP PA 23 \ / BITUMINOUS WATERPROOFING pG, W/ GALVANIZED SHEET METAL FLASHING ON TOP EXPANSION JOINT MAT'L a CONCRETE STEM AND CONT. FOOTING PER PLAN d 4< Q A Q 4 O O ° ° a ° CONCRETE WALL TO WOOD FLOOR 115 3LK'G (SEE aN) P.T. POST 'C4Z (SEE aN) "4 s BOTT. :H WAY REINFORCED PAD / SQUARE SCOOP FOOTING 14 13 Structural Design by: W.H. CONSULTANT 1590 OAKI.AND RD., STE B112 SAN JOSE, CA 95131 (949)-229-3357 hdo•whengineeriaggroup.com QROFESS/C O�G 0 0 9` F Z , G� w No.C88467 * Exp.03-31-2 �qT CIVII- �P F OF- ONO Y ) N N Cn Q U C) ry Q J Q W W Z U) O ry U 0 QL a REVISIONS 01ST PC— 07.28.2021 Q 2ND PC— 09.08.2021 QSITE REVISION 12.07.2 QSITE REVISION 1.18.22 QSITE REVISION 3.7.22 Title: FOUNDATIOI DETAILS Date: 09-08-2021 Scale: PER PLAN Drawn By. L.J. Job: 21165 Sheet: FD-2 —Of —Sheets i