NOTICE OF INCOMPLETE FILING
November 1, 2022
Hayer Architecture
445 Marine View Avenue
Suite 280
Del Mar, CA 92014
Attn: Troy Weiland
Application No.
• Coastal Development Permit
(PA2022-0214)
Address 2761 Bay Shore Drive
Please be advised that after reviewing the subject application, your submittal has been
deemed incomplete and further information is required before we are able to proceed
with the application process.
The following documentation is required to complete the application:
1. Planning: Please see the attached Planning Division Plan Check Corrections list.
All corrections must be addressed. At the time of resubmittal, submit a written
response to the correction list and redlined plans.
2. Public Works: Please see the attached redline plans from Public Works.
a. Ensure the door/gate swing does not project into the alley way and
easement area.
b. Remove all projection encroachments (including lattice and roof eaves) into
the alley way and easement area.
3. Notice of Application Filing: Please see the attached Notice of Application Filing.
The Notice of Application Filing must be posted on site at a conspicuous place,
easily readable by the public and placed as close as possible to the site of the
proposed development. The notice must also be posted on weatherproof paper.
Prepare and post the notice on site and submit a photo of the posting with clear
location either by email to jtran@newportbeachca.gov or by uploading directly to
City Virtual Connect (CiViC) portal. A copy of the notice for posting may also be
picked up in office.
Hearing Date: TBD
PA2022-0214_Incomplete Ltr
Page 2
For your information: Response sheets from Building and Fire with comments and
conditions have been attached. Please be sure to review and ensure you are aware of the
provided comments and conditions.
Upon verification of completion, the application will be processed and scheduled for a
Zoning Administrator Hearing. Should you have any questions regarding submittal
requirements, please contact Jenny Tran, Assistant Planner, at 949-644-3212 or
jtran@newportbeachca.gov.
By:
____________________________
Jenny Tran, Assistant Planner
Attachments: Planning Division Plan Check Corrections
Redline Plans
Notice of Application Filing
Building, Public Works, and Fire Response Sheets
c:
Troy Weiland
445 Marine View Avenue
Suite 280
Del Mar, CA 92014
City of Newport Beach
Community Development Department
100 Civic Center Drive / P.O. Box 1768
Newport Beach, CA 92658
Phone: (949) 644-3200
www.newportbeachca.gov
PLANNING DIVISION
PLAN CHECK
CORRECTIONS
F:\Users\CDD\Shared\Admin\Planning_Division\Current_Templates Revised 09-11-18 – CDD
Plan Checker Jenny Tran
Phone No: 949.644.3212
Email Address: jtran@newportbeachca.gov:
PLAN CHECK NO. (PA2022-0214) ADDRESS: 2761 Bay Shore Drive
CORRECTION DATE: 10/31/2022
CORRECTIONS:
Scope of Work: Coastal Development Permit for SFR
Setbacks: F: 10’, S: 3’, R: 10’ (alley)
1. Provide the calculations for buildable area (less setbacks), floor area limitation (buildable
area x 2), and open volume area requirements on Sheet T1.
a. The open volume area requirement is calculated at buildable area x 15%. Provide
the square footage of proposed open volume area to meet this requirement.
2. On the Site Plan (Sheet A1.1) show the 10’ utilities easement in the rear of the property.
3. Accessory structures including fences, hedges, walls, and retaining walls are limited to 6
feet in the side setback and 42 inches in the front setback. Label the height of all walls and
fences from natural grade to the highest point.
4. Roof overhangs and eaves may encroach up to 30 inches into required side setback areas
provided it does not project closer than 24 inches from the side property line. Show the
dimension of all roof overhangs and eaves to property line to ensure they comply with this
requirement.
5. Remove all projections encroaching into the alley (see redlines from Public Works).
6. Provide a sheet showing the outline of the proposed structure over a topographic survey
(stamped and signed by a licensed surveyor) to verify the slope and established grade to
be used for measuring height.
The established grade shall be determined using the average of the elevations at each
corner of a four-sided polygon that most closely approximates the actual footprint of the
proposed structure within the buildable area. (A + B + C + D = X; X ÷ 4).
7. The maximum height is 29’ for sloped roofs and 24’ for flat roofs. Label the established
grade on all elevations and show the overall height of the structure as well as the height
from established graded to all deck rails and flat elements.
8. The Housing Crisis Act Compliance for Demolitions form must be completed and signed by
the property owner. The form shall be copied into the demolition/construction plans before
the issuance of a building permit.
Please submit written responses to this corrections list and redlined plans at the time of
resubmittal.
SEPARATE PERMITSTHE FOLLOWING ITEMS ARE SEPARATE SUBMITTALS & NOT A PART OF THIS PERMIT.SITE WALLS, RETAINING WALLS, TRASH ENCLOSURES, CARPORTS, SITE LIGHTING,TEMPORARY POWER POLES, EMERGENCY GENERATORS, GREASE INTERCEPTORS, &SPRAY BOOTHS REQUIRE SEPARATE SUBMITTALS, APPORVALS AND PERMITS. THESEITEMS MY BE ON YOUR PLANS BUT ARE NOT PART OF THE BUILDING APPROVAL.FIRE SPRINKLER SYSTEMCAL-OSHA NOTES1. A CONSTRUCTION PERMIT IS REQEQUIRED FOR CONSTRUCTION OF TRENCHESOR EXCAVATIONS WHICH ARE FIVE FEET OR DEEER AND INTO WHICH A PERSON ISREQUIRED TO DESCEND, CONSTRUCTION OF ANY BUILDING , STRUCTURE,SCAFFOLDING OR FALSEWORK MORE THAT NHREE STORIES HIGH OR THE EQUIVALENTHEIGHT (36 FT.), DEMOLITION OF ANY BUILDING OR STRUCTURE, OR DISMANTLING OFSCAFFOLDING OR FALSEWORK SYSTEMS MORE THAN THREE STORIES HIGH, OR THEEQUIVALENT HEIGHT (36 FT.).OWNER:DEAN SPANOS2761 BAYSHORE DRIVENEWPORT BEACH, CA 92663PROJECT ADDRESS:BAYSHORES COMMUNITY2761 BAYSHORE DRIVENEWPORT BEACH, CA 92663APN: 049-192-07LEGAL DESCRIPTIONLOT 22 OF TRACT NO. 1014, IN THE CITY OF NEWPORT BEACH,COUNTY OF ORANGE, STATE OF CALIFORNIA AS PER MAPRECORDED IN BOOK 33, PAGE 31, OF MISCELLANEOUS MAPSIN THE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY.PROJECT INFORMATIONAREA TABULATIONSSHEET INDEXPROJECT TEAMPROJECT DESCRIPTIONVICINITY MAPSCOPE OF WORK:DEMOLITION OF EXISTING 2,200 S.F. SINGLE FAMILY DWELLING.CONSTRUCTION OF A NEW 1,977 SQ. FT. SINGLE FAMILY DWELLINGWITH A 669 S.F. ATTACHED 2-CAR GARAGE AND A 616 SQ. FT. UPPERLEVEL TERRACE. ASSOCIATED GRADING PLANS / SITE WALLS, FIRESPRINKLERS, AND SWIMMING POOL BY SEPARATE PERMIT.SWIMMING POOL & SPAARCHITECT Hayer Architecture 445 Marine View Drive, Suite 280 Del Mar, CA 92014 (858) 792-2800GEOTECHNICAL ENGINEER Coast Geotechnical Inc. 1200 W. Commonwealth Ave Fullerton, CA 90638 (714) 870-1211CIVIL ENGINEER Thomas M. Ruiz, Civil Engineer 11 Thornbird Aliso Viejo, CA 92656 (714) 580-7455LANDSCAPE ARCHITECT Garden Studio Design 2732 E. Coast Hwy Ste A. Corona Del Mar, CA 92625 (714) 334-0990project no.:permit no.:PERMIT-S I T E A R E A 4,000 SF0.092 ACRESB U I L D I N G A R E AI N T E R I O RMAIN LEVELTOTAL HABITABLEGARAGE | MECH | STGG R O S S F L O O R A R E A E X T E R I O R 944 SF1,977 SF 669 SF2,646 SF 616 SFUPPER EXTERIOR TERRACEGRADING PLANS & SITE WALLSNORTHN.T.S.L O T C O V E R A G E66.15%1.SEE FIRE PROTECTION PLANS / SPECS UNDER SEPARATE PERMIT. THE PROJECTSHALL BE 100% SPRINKLERED WITH NFPA TYPE 13D RESIDENTIAL SYSTEM AND/OR ASGOVERNED BY CURRENTLY ADOPTED CRC SECTION 313, CFC FIRE PREVENTION ANDPROTECTION CODE, AND AMENDMENTS AS LOCALLY ADOPTED..2. ANY REQUIRED APPROVALS MUST BE OBTAINED FROM THE FIRE AND HAZARDPREVENTION SERVICES BEFORE THE BUILDING IS OCCUPIED.3. COMPLETE PLANS AND SPECIFICATIONS FOR FIRE ALARM SYSTEMS;FIRE-EXTINGUISHING SYSTEMS, INCLUDING AUTOMATIC SPRINKLERS AND WET & DRYSTANDPIPES; HALON SYSTEMS AND OTHER SPECIAL TYPES OF AUTOMATIC FIRE-EXTINGUISHING SYSTEMS; BASEMENT PIPE INLETS; AND OTHER FIRE-PROTECTIONSYSTEMS AND APPURTENANCES THERETO SHALL BE SUBMITTED TO FIRE AND HAZARDPREVENTION SERVICES FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION.4.FIRE APPARATUS ACCESS ROADS AND WATER SUPPLIES FOR FIRE PROTECTIONSHALL BE INSTALLED AND MADE SERVICEABLE PRIOR TO AND DURING TIME OFCONSTRUCTION. (CFC 1408, 1410, 1412, 1413).5.BUILDINGS UNDERGOING CONSTRUCTION ALTERATION OR DEMOLITION SHALL BE INACCORDANCE WITH CFC CHAPTER 14 (CFC 1401.1)6.DECORATIVE MATERIALS SHALL BE MAINTAINED IN A FLAME-RETARDANT CONDITION.(TITLE 19, SECT. 3.08, 3.21; CFC 804).7.FIRE-EXTINGUISHING SYTEMS SHALL BE INSTALLED IN ACCORDANCE WITH CFCSECTION 903.8.AN APPROVED AUDIBLE SPRINKLER FLOW ALARM (BELL) SHALL BE PROVIDED ONTHE EXTERIOR OF THE BUILDING IN AN APPROVED LOCATIONN. (CFC 903.4.2).9.ALL VALVES CONTROLLING THE WATER SUPPLY FOR AUTOMATIC SPRINKLERSYSTEMS AND WATER FLOW SWITCHES ON ALL SPRINKLER SYSTEMS SHALL BEELECTRICALLY MONITORED WHERE THE NUMBER OF SPRINLKERS IS 20 OR MORE (CFC903.4).10.ADDRESS SHALL BE RROVIDED FOR ALL NEW AND EXISTING BUILDINGS IN APOSITION AS TO BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET OR ROAD FRONTINGTHE PROPERTY. (CFC 505.1, FHPS P-00-6)11. BUILDING NUMBERS SHALL BE EASILY VISIBLE AND LEGIBLE FROM THE STREET ORROAD FRONTING THE PROPERTY. NUMBERS SHALL BE 4" MINIMUM IN HEIGHT AND OF ACONTRASTING COLOR.T1TOPO 1TITLE & INDEXTOPOGRAPHICAL SURVEYSITEBUILDING DEPT NOTESGENERAL FIRE NOTESA1.1SITE | FLOOR PLAN - MAIN LEVELA1.2FLOOR PLAN - UPPER LEVELA1.3ROOF PLANA2.0BUILDING ELEVATIONSA2.1BUILDING ELEVATIONSA3.0BUILDING SECTIONSL-1HARDSCAPE PLANL-2PLANTING PLANL-3ELEVATIONSL-4LIGHTING PLANL-5IRRIGATION PLANL-6IRRIGATION NOTESC2C4C5PRECISE GRADING PLANEROSION CONTROL PLANGEOTECHNICAL RECOMMENDATIONS-2,646 SF / 4,000 SFDEFERRED SUBMITTALSTHE FOLLOWING ITEMS ARE DEFERRED SUBMITTALS & ARE INCLUDED AS APART OF THIS PERMIT.PV SYSTEM IS A DEFERRED SUBMITTAL AND IS REQUIRED TO BE APPROVEDAND INSTALLED PRIOR TO BUILDING FINAL. IT WILL NOT BE UNDER ASEPARATE PERMIT. SOLAR INSTALLER WILL BE REQUIRED TO SUBMIT A FULLSOLAR SUBMITTAL ACCORDING TO BIGHORN SOLAR GUIDELINES.PHOTOVOLTAIC SOLAR ELECTRICAL SYSTEMSPANOS RESIDENCEUPPER LEVEL1,033 SFL A N D S C A P E A R E AHARDSCAPESOFTSCAPEPOOLT O T A L L A N D S C A P E A R E A2,311 SF1,027 SF 836 SF 448 SF1.GENERAL PLAN LAND USE:RS-D2.ZONING DISTRICT:R-13.COASTAL LAND USE PLAN:RSD-B4.COASTAL ZONE DISTRICT:R-15.GROSS SQ. FOOTAGE:2,646 SQ. FT.6.PROPOSED BUILDING HEIGHT: 26’-9”7.OCCUPANCY:R3 | U8.CONSTRUCTION TYPE:V-B9.FIRE PROTECTION:SPRINKLERED10.NUMBER OF UNITS:ONE11.NUMBER OF FLOORS:TWO12.NUMBER OF BEDROOMS:TWO13.PARKING SPACES:TWO OFF-STREET, ENCLOSED14.EXISTING LAND USE:ONE RESIDENTIAL UNIT15.PROPOSED LAND USE:ONE RESIDENTIAL UNITGRADING EARTHWORKRAW CUT:50 C.Y.RAW FILL:15 C.Y.BAYSHORES COMMUNITY2761 BAYSHORE DRIVECONSTRUCTION NOTESALL CONSTRUCTION MATERIALS & INSTALLATION SHALL COMPLY WITH: THE 2019 CALIFORNIA BUILDING STANDARDS CODE, CCR TITLE 242019 CALIFORNIA BUILDING CODE(CBC)2019 CALIFORNIA RESIDENTIAL CODE (CRC)2019 CALIFORNIA ELECTRICAL CODE (CEC)2019 CALIFORNIA MECHANICAL CODE (CMC)2019 CALIFORNIA PLUMBING CODE (CPC)2019 CALIFORNIA ELEVATOR SAFETY CODE2019 CALIFORNIA HISTORICAL BUILDING CODE2019 CALIFORNIA FIRE CODE2019 CALIFORNIA EXISTING BUILDING CODE2019 CALIFORNIA GREEN BUILDING STANDARDS CODE (CALGreen/ CGBC)2019 BUILDING ENERGY EFFICIENCY STANDARDS (TITLE 24 PARTS 6 & 11)2019 CALIFORNIA REFERENCED STANDARDS CODEAMERICANS WITH DISABILITIES ACT (ADA) - MOST CURRENT EDITIONAND ALL OTHER AMMENDMENTS AND ORDINANCES OF LOCAL GOVERNING AUTHORITIES.1.IF THE CONTRACTOR PERFORMS ANY WORK KNOWING IT TO BECONTRARY TO SUCH LAWS, ORDINANCES RULES AND REGULATIONS, ANDWITHOUT SUCH NOTICE TO THE DESIGNER AND/OR OWNER, HE SHALL ASSUMEALL RESPONSIBILITY AND SHALL BEAR ALL COSTS ATTRIBUTABLE THERETO.CONTRACTOR TO NOTIFY DESIGNER AND/OR OWNER OF ANY VARIANCES IN THECONSTRUCTION DOCUMENTS.2.ALL REQUIREMENTS AND REGULATIONS PERTAINING TO THEHANDICAPPED AND OSHA MUST BE INCORPORATED IN THE WORK EVEN THOUGHTHEY MAY NOT BE LISTED INDIVIDUALLY AND SEPARATELY IN EITHER THEDRAWINGS OR SPECIFICATIONS.3.AT ALL TIMES THE CONTRACTOR SHALL BE SOLELY AND COMPLETELYRESPONSIBLE FOR THE CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OFTHE PERSONS AND PROPERTY AND FOR ALL INDEPENDENT ENGINEERINGREVIEWS OF THESE CONDITIONS. THE ARCHITECT'S AND ENGINEER'S JOB SITEREVIEW IS NOT INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THECONTRACTOR'S SAFETY MEASURES.4.THE SOIL ENGINEER IS TO VERIFY THE SITE CONDITIONS ARE THE SAME ASASSUMED IN THE SOIL REPORT. THE SOIL ENGINEER NEEDS TO VERIFY THE SOILIS COMPACTED 90%. THE SOIL ENGINEER IS TO VERIFY THE FOOTINGS ARECARRIED TO THE PROPER BEARING STRATA.1.BUILDING ADDRESS NUMBERS SHALL BE VISIBLE AND LEGIBLE FROM THE STREETOR ROAD FRONTING THE PROPERTY.2.RESIDENTIAL TRASH RECEPTACLES TO BE LOCATED IN WALLED RUBBISH AREA.3.COAST-BAYSHORE BUS TRANSIT STOP LOCATED .2 MILES FROM SITE.4.NO BIKE RACKS OR LOCKERS OTHER THAN OWNER'S GARAGE STORAGE.5.ALL EXTERIOR LIGHTING FIXTURES SHALL BE UNOBTRUSIVE AND SHIELDED SUCHTHAT NO LIGHT SHALL FALL EXCESSIVELY BEYOND SITE BOUNDARIES AND SHALLCOMPLY WITH LOCAL LIGHTING POLLUTION ORDINANCE & CGBC.6.PROVIDE 1/4" PER FOOT (MIN.) SLOPE AT ALL UPPER ROOF DECKS.7.ALL ROOF ASSEMBLIES SHALL BE CLASS A FIRE RESISTANCE RATED.general notes1.AUTOMATIC IRRIGATION CONTROLLER(S) INSTALLED BY THE BUILDER SHALL BEIN PLACE FOR FINAL INSPECTION2.CONTROLLERS SHALL BE WEATHER - OR SOIL - MOISTURE BASED THATAUTOMATICALLY ADJUSTS IRRIGATION IN RESPONSE TO CHANGES IN PLANT NEEDS ASWEATHER CONDITIONS CHANGE3.WEATHER-BASED CONTROLLERS WITHOUT INTEGRAL RAIN SENSORS ORCOMMUNICATION SYSTEMS THAT ACCOUNT FOR LOCAL RAINFALL SHALL HAVE ASEPARATE WIRED OR WIRELESS RAIN SENSOR WHICH CONNECTS OR COMMUNICATESWITH THE CONTROLLER(S). SOIL MOISTURE BASED CONTROLLERS ARE NOT REQUIREDTO HAVE RAIN SENSOR INPUTcalgreen notes:ofsheetsheetsheet titlekey mapstatusissue dateConceptPreliminaryDesign Dev.ReviewPlan CheckNOT FOR CONSTRUCTIONFOR CONSTRUCTIONConstructionOtherrevisionsprojecth a y e r a r c h i t e c t u r e 4 4 5 M a r i n e V i e w A V ES u i t e 2 8 0t 8 5 8 7 9 2 2 8 0 0f 8 5 8 7 9 2 2 8 0 2arch@hayerarchitecture.comD e l M a r , C A 9 2 0 1 4RESIDENCESPANOS2761 BAYSHORE DRIVENEWPORT BEACH, CA 9266309/27/2022 SCHEMATIC - ARC #3BAY SHOREScity09/30/2022 CDP SUBMITT1GENERAL NOTES/ INDEX
23BAYSHORE DRIVE℄LOT 22TRACT NO. 1014M.M. 33/31 LOT 23 LOT 21N70°08'56"W 99.95'N19°50'03"E 40.00'N70°08'36"W 99.94'N19°50'58"E 40.01'
ALLEY
BASIS OF BEARINGS THE BASIS OF BEARINGS SHOWN HEREON ARE BASED ON THE PROPERTYLINE OF LOT 22 HAVING A BEARING OF N19°50'58"E PER TRACT NO. 1014, M.M.33/31.VICINITY MAPBENCHMARK INFORMATION2761 BAYSHORE DRIVE
NEWPORT BEACH, CA 92663
(APN: 049-192-07)
TOPOGRAPHIC MAP
1 1TITLE REPORT/EASEMENT NOTES2761 BAYSHORE DRIVENEWPORT BEACH, CA 92663(APN:049-192-07)NO TITLE REPORT PROVIDEDLEGAL DESCRIPTIONREAL PROPERTY SITUATED IN THE CITY OF NEWPORT BEACH,COUNTY OF ORANGE, STATE OF CALIFORNIA AND ISDESCRIBED AS FOLLOWS:LOT 22 OF TRACT NO. 1014, IN THE CITY OF NEWPORT BEACH,COUNTY OF ORANGE, STATE OF CALIFORNIA AS PER MAPRECORDED IN BOOK 33, PAGE 31, OF MISCELLANEOUS MAPS INTHE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY.LCEXISTING ELEVATIONLEGEND( )ACASPHALT PAVEMENTFOUND MONUMENTSEARCHED, FOUND NOTHING; SETNOTHINGFSFLFINISHED SURFACEFLOWLINEFFGFINISHED FLOOR GARAGECONCRETE SURFACET.B.M.TEMPORARY BENCHMARKSET ON A FOUND NAIL & TAGSTAMPED RCE28329ELEVATION = 12.95 FEETHUNTINGTON BEACH, CALIFORNIA 92646PHONE:(714)488-5006 FAX:(714)333-4440
APEXLSINC@GMAIL.COMPAUL D. CRAFT, P.L.S. 8516 DATENOTE: SECTION 8770.6 OF THE CALIFORNIA BUSINESS AND PROFESSIONS CODESTATES THAT THE USE OF THE WORD CERTIFY OR CERTIFICATION BY ALICENSED LAND SURVEYOR IN THE PRACTICE OF LAND SURVEYING OR THEPREPARATION OF MAPS, PLATS, REPORTS, DESCRIPTIONS OR OTHER SURVEYINGDOCUMENTS ONLY CONSTITUTES AN EXPRESSION OF PROFESSIONAL OPINIONREGARDING THOSE FACTS OR FINDINGS WHICH ARE THE SUBJECT OF THECERTIFICATION AND DOES NOT CONSTITUTE A WARRANTY OR GUARANTEE,EITHER EXPRESSED OR IMPLIED.LICENSE RENEWAL DATE 12/31/22STATEOFCALI
FOR
N
IA
PAUL
DOMINICKCRAFTExp. 12/31/22No. 8516PROFESSI
ONALLANDSURVEYORFFFINISHED FLOORWATER METERWMEGEDGE OF GUTTERGAS METERGMCENTERLINETCTOP OF CURBGRAPHIC SCALESURVEYOR OR ENGINEER SHALL PERMANENTLY MONUMENT PROPERTYCORNERS OR OFFSETS BEFORE STARTING GRADING.PLEASE CALL PAUL CRAFT @ 714-488-5006 TO SCHEDULE.SURVEYOR'S NOTESBLOCK WALLNGNATURAL GROUNDBENCHMARK NO: 3K-24A-82DESCRIBED BY OCS 2002 - FOUND 3 3\4" OCS ALUMINUM BENCHMARKDISK STAMPED "3K-24A-82", SET IN THE TOP OF A CONCRETE BRIDGEDECK. MONUMENT IS LOCATED IN THE SOUTHWEST CORNER OF THEINTERSECTION OF PACIFIC COAST HIGHWAY AND NEWPORT BAYCROSSING, 42 FT. SOUTHERLY OF THE CENTERLINE OF PCH AND 37FT. EASTERLY OF THE WEST END OF THE SOUTHERN GUARD RAILALONG BRIDGE. MONUMENT IS SET LEVEL WITH THE SIDEWALK.ELEVATION: 19.353 FEET (NAVD88), YEAR LEVELED 2015ACUAIR CONDITION UNITCATVCABLE TV BOXWOODEN FENCE (WDF)GRASS SURFACEEVTELECTRICAL VAULTCLMCOLUMNPAPLANTER AREATFTOP OF FENCETWTOP OF WALL1/17/2022
45°45°45°45°
45°
45°
45°
45°Garage22'-0" x 21'-6"Golf Cart12'-0" x 9'-6"10'-0" rear SB51'-6"10'-6"16'-0"1'-0"10'-0" front SB9'-9"40'-0"100'-0"up4'-0" SB4'-0" SB
curbBreakfastKitchenDiningPowdrLaundMedia18'-0" x 12'-0"Dining18'-0" x 10'-0"Kitchen18'-0" x 8'-0"EntryF.F. = 0'-0"(14.0')Pool16'-0" x 28'-0"Baja ShelfdnFAUStgrefrangesinkdwbar/ buffet
(N) 6' h. property line wallplaster over CMUAlley
Bayshore DrivePatio 32'-0"storagew/dtvPool EquipVaultcenterline(N) 6' high wall w/wood siding & shapedwood cap to matchadjacent houseExisting Residenceall materials & details to bematched on new residence1A2.0trash2A2.03A2.1BA3.04A2.1AA3.0pool equipment must meetthe sound decibel ratingstandards of the cityplantpocketplantpocket1'-0"(N) 66" h. gate tomatch landscapeelevation sheet L-3(N) stone pavers (-1")(N) wood deck (-1/2")see landscape sheet L-1for materials(E) 6' h. property line wallplaster over CMUto remain(N) 60" h.wood gate(see landscape sht. L-3)24"(N) plaster pilasters &wood infill tomatch landscapesheet L-3(3' high max.)HOA setbackmailboxsee landscapesheet L-3concrete pavingsee landscape sheetL-1 for materialswood trellisabove(N) 66" h. gate tomatch landscapeelevation sheet L-3F.G. = -8" (13.3'), typofsheetsheetsheet titlekey mapstatusissue dateConceptPreliminaryDesign Dev.ReviewPlan CheckNOT FOR CONSTRUCTIONFOR CONSTRUCTIONConstructionOtherrevisionsprojecth a y e r a r c h i t e c t u r e 4 4 5 M a r i n e V i e w A V ES u i t e 2 8 0t 8 5 8 7 9 2 2 8 0 0f 8 5 8 7 9 2 2 8 0 2arch@hayerarchitecture.comD e l M a r , C A 9 2 0 1 4RESIDENCESPANOS2761 BAYSHORE DRIVENEWPORT BEACH, CA 9266309/27/2022 SCHEMATIC - ARC #3BAY SHOREScity09/30/2022 CDP SUBMITA1.1SITE| FLOOR PLAN - MAIN LEVELSCALE: 1/4" = 1'-0"SITE| FLOOR PLAN - MAIN LEVEL0 2 4 8 F T.NORTHMAIN LEVEL 944 SFUPPER LEVEL 1,033 SFTOTAL HABITABLE1,977 SFGARAGE | MECH | STG669 SFUPPER TERRACE 616 SF
45°
45°45°
45°
45°
45°
45°45°Bedroom 116'-0" x 13'-0"Bedroom 215'-0" x 15'-0"Bath 16'-0" x 15'-6"Bath 213'-0" x 7'-6"shwrshwrwcwccloscloshvacclos
chaisefirepitTerrace18'-6" x 30'-0"+13'-3" (27.3')dnup10'-0" front SB40'-0"100'-0"4'-0" SB4'-0" SB 32'-0"1A2.02A2.03A2.14A2.110'-0" rear SB51'-6"1'-0"roof overhang+18" h. clad inflagstone+11'-3 1/2"(25.3')A1.2FLOOR PLAN - UPPER LEVELSCALE: 1/4" = 1'-0"0 2 4 8 F T.ofsheetsheetsheet titlekey mapstatusissue dateConceptPreliminaryDesign Dev.ReviewPlan CheckNOT FOR CONSTRUCTIONFOR CONSTRUCTIONConstructionOtherrevisionsprojecth a y e r a r c h i t e c t u r e 4 4 5 M a r i n e V i e w A V ES u i t e 2 8 0t 8 5 8 7 9 2 2 8 0 0f 8 5 8 7 9 2 2 8 0 2arch@hayerarchitecture.comD e l M a r , C A 9 2 0 1 4RESIDENCESPANOS2761 BAYSHORE DRIVENEWPORT BEACH, CA 9266309/27/2022 SCHEMATIC - ARC #3BAY SHOREScity09/30/2022 CDP SUBMITNORTHFLOOR PLAN - UPPER LEVELMAIN LEVEL 944 SFUPPER LEVEL 1,033 SFTOTAL HABITABLE1,977 SFGARAGE | MECH | STG669 SFUPPER TERRACE 616 SF
wood shake roofingto match adjacenthouse installed asclass 'A' assembly4:12 slope, typ.Belgard 'lagoon-sharkskin' porcelain tileover Dex-O-Tex system1/4"/ ft. slope, typ.+42" woodguardrail -painted whiteACACroofhatchPV solarpanel arrayPV solarpanel arraymechanical equip. to be screenedfrom view & must meet the sounddecibel rating standards of the cityRecessedRoof Well+26'-1"(40.08')+ 21'-9"(35.8')19", typ.24", typ.+ 13'-3"+9" wood cornice -painted whitefirepit+18" h. clad inflagstonecoppergutters, typ.painted woodtrellis @ mainlevel below+16'-9"(30.8')A1.3ROOF PLANSCALE: 1/4" = 1'-0"0 2 4 8 F T.ofsheetsheetsheet titlekey mapstatusissue dateConceptPreliminaryDesign Dev.ReviewPlan CheckNOT FOR CONSTRUCTIONFOR CONSTRUCTIONConstructionOtherrevisionsprojecth a y e r a r c h i t e c t u r e 4 4 5 M a r i n e V i e w A V ES u i t e 2 8 0t 8 5 8 7 9 2 2 8 0 0f 8 5 8 7 9 2 2 8 0 2arch@hayerarchitecture.comD e l M a r , C A 9 2 0 1 4RESIDENCESPANOS2761 BAYSHORE DRIVENEWPORT BEACH, CA 9266309/27/2022 SCHEMATIC - ARC #3BAY SHOREScity09/30/2022 CDP SUBMITNORTHROOF PLAN
PROPERTY LINE
4' SYSB
PROPERTY LINE
4' SYSBwood shakes installedas class 'A' assemblycopper gutters &downspouts w/painted wood fasciasDINING/ MEDIA PL. HT.(+12'-0 5/8" | 26.1')6' high pool wallin foregroundpainted woodguardrailpainted shiplapwood sidingwood w/ aluminumcladding doors &windows*ALL MATERIALS& COLORS TOMATCH ADJACENTHOUSEpaintedwood corniceSTAIRWELL PL. HT.(+21'-4 1/8" | 35.3')TERRACE FIN. FLR.(+13'-3" | 27.3')26'-9"painted woodtrim, typ.oil rubbed bronzelight fixturesrecessedmechanicalwell beyondFIN. GRADE(-8" | 13.3')MAIN LEVEL FIN. FLR.(+0'-0" | 14' DATUM)PROPERTY LINE
10' FYSB
PROPERTY LINE10' RYSB
DINING/ MEDIA PL. HT.(+12'-0 5/8" | 26.1')TERRACE FIN. FLR.(+13'-3" | 27.3')26'-9"
BAYSHORE DRIVE ENTRY PL. HT.(+10'-0 5/8" | 24.1')UPPER LEVEL FIN. FLR.(+11'-3 1/2" | 25.3')BEDROOM PL. HT.(+21'-4 1/8" | 35.3')ALLEY
swimming pool beyond19", typ.24", typ.24"FIN. GRADE(-8" | 13.3')MAIN LEVEL FIN. FLR.(+0'-0" | 14' DATUM)RIDGE HT.(+26'-1" | 40.08')EXTERIOR BUILDING ELEVATIONSA2.01ofsheetsheetsheet titlekey mapstatusissue dateConceptPreliminaryDesign Dev.ReviewPlan CheckNOT FOR CONSTRUCTIONFOR CONSTRUCTIONConstructionOtherrevisionsprojecth a y e r a r c h i t e c t u r e 4 4 5 M a r i n e V i e w A V ES u i t e 2 8 0t 8 5 8 7 9 2 2 8 0 0f 8 5 8 7 9 2 2 8 0 2arch@hayerarchitecture.comD e l M a r , C A 9 2 0 1 4RESIDENCESPANOS2761 BAYSHORE DRIVENEWPORT BEACH, CA 9266309/27/2022 SCHEMATIC - ARC #3BAY SHOREScity09/30/2022 CDP SUBMITBUILDING ELEVATION - EAST - FRONT0 2 4 8 F T.SCALE: 1/4" = 1'-0"(NO FOREGROUND WALLS SHOWN)2BUILDING ELEVATION - SOUTH - LEFT0 2 4 8 F T.SCALE: 1/4" = 1'-0"'SHEPHERD' WALL SCONCEBY SEAN LAVIN
PROPERTY LINE
4' SYSB
PROPERTY LINE
4' SYSB
MAIN LEVEL FIN. FLR.(+0'-0" | 14' DATUM)BEDROOM PL. HT.(+21'-4 1/8" | 35.3')26'-9"FIN. GRADE(-8" | 13.3')ENTRY PL. HT.(+10'-0 5/8" | 24.1')UPPER LEVEL FIN. FLR.(+11'-3 1/2" | 25.3')6' high propertyline wallsboth sidespainted woodtrim, typ.wood gatesboth sidescopperdownspoutpainted shiplapwood sidingwood w/ aluminumcladding doors &windowswood & frosted glassoverhead sectionalgarage doorswood shakesinstalled as class'A' assemblypainted woodtrellis & bracesRIDGE HT.(+26'-1" | 40.08')DINING/ MEDIA PL. HT.(+12'-0 5/8" | 26.1')TERRACE FIN. FLR.(+13'-3" | 27.3')26'-9"
BAYSHORE DRIVE
ENTRY PL. HT.(+10'-0 5/8" | 24.1')UPPER LEVEL FIN. FLR.(+11'-3 1/2" | 25.3')BEDROOM PL. HT.(+21'-4 1/8" | 35.3')PROPERTY LINE
PROPERTY LINE
10' RYSB
10' FYSB
ALLEYplaster pilasters &wood infill tomatch landscapesheet L-3(3' high max.)6' high wood cladproperty line wallw/ porcelain tileon pool sideswimming pool beyondEAVE HT. (TYP.)(+21'-9" | 35.8')pool vaultbeyondFIN. GRADE(-8" | 13.3')MAIN LEVEL FIN. FLR.(+0'-0" | 14' DATUM)EXTERIOR BUILDING ELEVATIONSA2.13ofsheetsheetsheet titlekey mapstatusissue dateConceptPreliminaryDesign Dev.ReviewPlan CheckNOT FOR CONSTRUCTIONFOR CONSTRUCTIONConstructionOtherrevisionsprojecth a y e r a r c h i t e c t u r e 4 4 5 M a r i n e V i e w A V ES u i t e 2 8 0t 8 5 8 7 9 2 2 8 0 0f 8 5 8 7 9 2 2 8 0 2arch@hayerarchitecture.comD e l M a r , C A 9 2 0 1 4RESIDENCESPANOS2761 BAYSHORE DRIVENEWPORT BEACH, CA 9266309/27/2022 SCHEMATIC - ARC #3BAY SHOREScity09/30/2022 CDP SUBMITBUILDING ELEVATION - WEST - REAR0 2 4 8 F T.SCALE: 1/4" = 1'-0"4BUILDING ELEVATION - NORTH - RIGHT0 2 4 8 F T.SCALE: 1/4" = 1'-0"
PROPERTY LINE
4' SYSB
PROPERTY LINE
4' SYSB
26'-9"BEDROOM PL. HT.(+21'-4 1/8" | 35.3')GARAGE PL. HT.(+9'-10 1/2" | 23.9')UPPER LEVEL FIN. FLR.(+11'-3 1/2" | 25.3')GarageMech. WellBedroom 16' high propertyline wallpainted shiplapwood sidingwood w/ aluminumcladding doors &windowscopperdownspout2 x 6 wood studwalls w/ 5/8" gyp.bd. interiorconc. ftg.per struct.EAVE HT. (TYP.)(+21'-9" | 35.8')wood shakesinstalled as class'A' assemblyBedroom 2CartsFIN. GRADE(-8" | 13.3')MAIN LEVEL FIN. FLR.(+0'-0" | 14' DATUM)PROPERTY LINE
10' FYSB
PROPERTY LINE10' RYSB26'-9"
BAYSHORE DRIVE
ALLEY
PoolDining| MediaMechGarageBEDROOM PL. HT.(+21'-4 1/8" | 35.3')ENTRY PL. HT.(+10'-0 5/8" | 24.1')UPPER LEVEL FIN. FLR.(+11'-3 1/2" | 25.3')FIN. SURFACE(-6" | 13.5', VERIFY)DINING/ MEDIA PL. HT.(+12'-0 5/8" | 26.1')TERRACE FIN. FLR.(+13'-3" | 27.3')9"
3'-6"Mech. WellTerraceBedroom 2GARAGE PL. HT.(+9'-10 1/2" | 23.9')pool vaultbeyondMAIN LEVEL FIN. FLR.(+0'-0" | 14' DATUM)RIDGE HT.(+26'-1" | 40.08')T.O. GUARDRAIL(+16'-9" | 30.8')BUILDING SECTIONSA3.0ofsheetsheetsheet titlekey mapstatusissue dateConceptPreliminaryDesign Dev.ReviewPlan CheckNOT FOR CONSTRUCTIONFOR CONSTRUCTIONConstructionOtherrevisionsprojecth a y e r a r c h i t e c t u r e 4 4 5 M a r i n e V i e w A V ES u i t e 2 8 0t 8 5 8 7 9 2 2 8 0 0f 8 5 8 7 9 2 2 8 0 2arch@hayerarchitecture.comD e l M a r , C A 9 2 0 1 4RESIDENCESPANOS2761 BAYSHORE DRIVENEWPORT BEACH, CA 9266309/27/2022 SCHEMATIC - ARC #3BAY SHOREScity09/30/2022 CDP SUBMIT0 2 4 8 F T.BBUILDING SECTION0 2 4 8 F T.SCALE: 1/4" = 1'-0"ABUILDING SECTIONSCALE: 1/4" = 1'-0"
HARDSCAPE LEGEND
1.Concrete Paving, Smooth Sand Finish (Top Cast #3), Davis Color 'Miami Buff'
2.2" - 3" Capitan Cobbles, Stacked Pattern:
a. Grout Color & Size: TBD
3.Azek 'Weathered Teak' Wood Planks
4.4" Green Seam, See Sheet L-2 for Plant Material
5.28' x 16' Pool with 5' x 16' Baja Shelf
a. Plaster: TBD
b. Waterline Tile: TBD
c. Coping: TBD
6.36" Ht. Pilaster and Fence, See Sheet L-3 'Pilaster and Fence Elevation'
7.36" Ht. Mailbox, See Sheet L-3 'Mailbox Elevation'
8.(2x) 18" Dia. Pot, See Sheet L-2 for Plant Material
9.Pool Equipment Vault Underneath Deck. Pool / Spa Equipment must meet the
City's sound decibel rating standards
10.5' Ht. Entry Gate, See Sheet L-3 'Pool Wall and Entry Gate Elevation'
11.6'-0" Ht. Property Wall to be Smooth Stucco Finish, Color: Omega #10
12.Wall Mounted Art Piece, Designer to Source
13.Vine Espalier, See Sheet L-3 'Vine Espalier' Elevation
14.Marathon II Sod
15.5'-0" Ht. Side Gate and Fence, See Sheet L-3 'Side Gate and Fence' Elevation
A.Contractor shall examine the site of proposed work noting existing conditions and proposed
work as shown on the plans. Notify landscape designer of discrepancies
B.Contractor shall stake proposed work prior to construction for review by landscape designer
C.Protect existing utilities, paving and structures from damage. Trenching adjacent to existing tree
drip lines to be done by hand to avoid root damage
D.Construction and installation of all landscape items shall be according to State, County, and
Local codes, Ordinances and up to CAL_OSHA safety orders regarding performance of work
E.Contractor to obtain required permits and comply with applicable codes
F.All Concrete edges to be 1/8" trowel
G.All Stucco edges to be 1/8" trowel
H.Contractor is responsible for damage to underground utilities and shall replace or repair same
required at contractors expense
I.Contractor shall assemble material samples including: flagstone, gravel, DG, stains, Stucco, etc.
for review by owner and landscape designer prior to construction
J.coordinate electrical, low voltage, and irrigation conduit sleeves prior to installation of new
pavement.
K.Contractor to coordinate work with other trades
L.Verify grades and elevations in field and notify landscape design of discrepancies
M.Contractor to review site for proper drainage and report apparent problems to landscape
designer
N.Contractor to verify location of any surface drains in concrete surface prior to pour for location
verification by owner and landscape designer
O.Contractor shall install this project utilizing the landscape industries B.M.P. Best Management
Practices
P.Contractor to provide direct drainage, low voltage, and irrigation to all pots
Q.Contractor to verify proper soil preparation specific to project climate, native soil, site
conditions.
R.Contractor shall use Netafim drip irrigation for all planters and pots.
S.Hardscape Contractor to install and coordinate built in low voltage lighting mounting hardware
and sleeves. For example, step lights, in ground lighting, wall lights etc.
T.CONTRACTOR TO REVIEW, SIGN, AND APPROVE GARDEN STUDIO'S DESIGN/CONSTRUCTION
NOTEBOOK AND AGREES TO BUILD PER THE SPECIFICATIONS IN THE NOTEBOOK
CONSTRUCTION NOTES
SJ SJ SJ SJ SJ
RIRIM
M
M
M
M
M
M
M
M
M
M
M
BL1BL1BL1
WB
WB RIS
P
P
BG1
O
BG1
BL1
BG1WB LA O
P O
WB LALA
C1BG1BG1
WBGBGBPP
SY P O SY C1
BG1 O
GB
O
BG1
GB
BG1
O
RI
RI
S
GB
BG1
O
LA
LA
MLMLMLMLMLMLRI
RI
S
GB
O
LA
SSJ
SJSY
SY
P
P
P
P O
BG1
BG1BG1
LA
LT
LT
LT
LT
LT
LT
LT
LT
LT
LT
LT
LT
45°
45°
45°
45°
45°45°
45°
45°
Media
Dining
Kitchen
Entry
Laundry
Powder
Golf Cart
Garage
Trash
Storage
BAYSHORE DRIVE10' Front Setback10' Rear Setback
4' SideSetback4' SideSetbackALLEY10' Rear Setback
2' HOA Front
Setback
L-1
Hardscape Plan
Contractor to Field Verify All
Measurements and Confirm
Details to Provide Accurate Bid
2732 East Coast Highway, Suite A
Corona Del Mar, CA 92625
949.673.5450
Date:
Revisions:
SCALE: 1/8" =1'-0"
0'2'4'8'16'SPANOS RESIDENCE2761 Bayshore Drive, Newport Beach, CA 9266308.29.2022 - Initial Meeting
Drawn By:
Sheet:
PM:
Contact Email:
ashley@gardenstudiodesign.com
RP
AS
08.23.2022ARDENST
U
DI
OD
E S I G NG08.30.2022 - HOA Submittal
09.27.2022 - HOA Submittal
3
1 2
2
5
4 8
1
9
7
6
6
10
11 1213
13
14
15
15
Westringia fruticosa 'Mundi'
Low Coast Rosemary 5 gal.12M
Olea europaea 'Montra'
Little Ollie Dwarf Olive 5 gal.10O
Westringia fruticosa 'Smokey'
Coast Rosemary 5 gal.4S
Pittosporum tenuifolium 'Golf Ball'
Golf Ball Pittosporum 5 gal.P 10
Salvia yangii
Russian Sage 5 gal.2
Rosa spp. 'Iceberg'
White Iceberg Rose 5 gal.5RI
Buxus microphylla ‘Green Beauty’ Globe
Green Beauty Boxwood Globe 24" dia.12BG1
Lavandula angustifolia
English Lavender 5 gal.7LA
Rosa ‘Iceberg’ Climbing
Iceberg Climbing Rose 15 gal.2RI
Trachelospermum jasminoides ‘Staked’
Star Jasmine 75 gal.SJ
Olea europaea 'Montra'
Little Ollie Dwarf Olive 5 gal.
SizeTrees Quantity
Shrubs
Vines
Groundcovers
Plant Legend:
Viola hederacea
Australian Violet Dirt Flats 6
Gaura lindheimerii ‘Whirling Butterflies’
Whirling Butterflies Gaura 1 gal.5WB
1 per Pot
2 Total
Pots
Sesleria autumnalis
Autumn Moor Grass 1 gal.37
Erodium reichardii ‘Album’
White Heron’s Bill Dirt Flats
Dymondia margaratae
Dymondia Dirt Flats
2
1
Crassula arborescens spp. undulatifolia
Blue Waves Jade PlantC1
Westringia fruticosa 'Grey Box'
Dwarf Coast RosemaryGB
Salvia yangii
Russian SageSY
ML Citrus x meyeri
Meyer Lemon 15 gal.6
1 gal.2
1 gal.2
SY
5 gal.6
48" Box
Multi-Trunk 1Olea europaea 'Wilsonii'
Fruitless Olive Tree
Ligustrum japonicum 'Texanum' Staked
Wax Leaf Privet 5 gal.12LT
1.Under no circumstances will there be any material substitutions, except with the
express consent of the Landscape Architect/Designer.
2.The contractor is responsible for the costs associated with procuring the services of
a soil testing laboratory to perform an Agricultural Suitability Analysis for both native
plants and traditional plant materials. Their recommendations are to be followed for soil
preparation and backfill amendment and procedures, and for maintenance fertilizer
applications. Two random samples shall be taken from each on-site stockpile of native soil
and delivered by the contractor to the soils testing laboratory.
3. For bidding purposes only, the contractor is to assume the following amendment
for soil preparation, and is to assume utilization of amended site soil for plant pit backfill:
Incorporate into the soil the following materials, per procedures described in the
specification. Material amounts per 1,000 square feet:
3 cubic yards Nitrogen Fortified Wood Compost
2 cubic yards Organic Fertilizer
100 lbs. Gypsum
30 lbs. Commercial Fertilizer
4.For soils less than 6% Organic Matter in the top six (6) inches of soil, compost at a
rate of a minimum of four cubic yards per 1,000 square feet of permeable area shall be
incorporated to a depth of six inches into the soil.
5.Backfill all Planters with B.D. White Top Soil Company 'Mixture 76', a Lightweight
Blended Soil for planters and rooftop planters.
Contact: B.D. White Top Soil Co. Inc.
19205 South Prairie Avenue
Torrance, Ca 90503
310.370.5511
6.A minimum three-inch (3) layer of mulch shall be applied on all exposed soil
surfaces of planting areas except turf areas, creeping or rooting ground covers, or direct
seeding applications where mulch is contradicted.
7. Class 1 Recycled Bark Mulch is required within planter areas at a depth of 3” for
shrub planters where planting consists of 1 gallon or larger plants. Soil shall not be visible
through mulch. Keep mulch three-inches (3”) clear of tree trunks and plant stems. Prior to
purchase or installation of the mulch, contractor is to submit a sample to the owner for
approval
PLANTING NOTES
SJ SJ SJ SJ SJ
RIRIM
M
M
M
M
M
M
M
M
M
M
M
BL1BL1BL1
WB
WB RIS
P
P
BG1
O
BG1
BL1
BG1WB LA O
P O
WB LALA
C1BG1BG1
WBGBGBPP
SY P O SY C1
BG1 O
GB
O
BG1
GB
BG1
O
RI
RI
S
GB
BG1
O
LA
LA
MLMLMLMLMLMLRI
RI
S
GB
O
LA
SSJ
SJSY
SY
P
P
P
P O
BG1
BG1BG1
LA
LT
LT
LT
LT
LT
LT
LT
LT
LT
LT
LT
LT
45°
45°
45°
45°
45°45°
45°
45°
Media
Dining
Kitchen
Entry
Laundry
Powder
Golf Cart
Garage
Trash
Storage
BAYSHORE DRIVE10' Front Setback10' Rear Setback
4' SideSetback4' SideSetbackALLEY10' Rear Setback
2' HOA FrontSetback
Contractor to Field Verify All
Measurements and Confirm
Details to Provide Accurate Bid
2732 East Coast Highway, Suite A
Corona Del Mar, CA 92625
949.673.5450
Date:
Revisions:
SCALE: 1/8" =1'-0"
0'2'4'8'16'SPANOS RESIDENCE2761 Bayshore Drive, Newport Beach, CA 9266308.29.2022 - Initial Meeting
Drawn By:
Sheet:
PM:
Contact Email:
ashley@gardenstudiodesign.com
RP
AS
08.23.2022ARDENST
U
DI
OD
E S I G NG08.30.2022 - HOA Submittal
09.27.2022 - HOA Submittal
L-2
Planting Plan
Contractor to Field Verify All
Measurements and Confirm
Details to Provide Accurate Bid
2732 East Coast Highway, Suite A
Corona Del Mar, CA 92625
949.673.5450
Date:
Revisions:SPANOS RESIDENCE2761 Bayshore Drive, Newport Beach, CA 9266308.29.2022 - Initial Meeting
Drawn By:
Sheet:
PM:
Contact Email:
ashley@gardenstudiodesign.com
RP
AS
08.23.2022ARDENST
U
DI
OD
E S I G NG08.30.2022 - HOA Submittal
09.27.2022 - HOA Submittal
L-3
Elevations
0'1'2'4'
SCALE: 1/2" =1'-0"
Legend
Pilaster and Fence Elevation
Scale: 12" = 1'
3
3'2'-9"4
1.Concrete Cap, Smooth
Sand Finish Topcast #3,
Davis Color 'Miami Buff'
2.Pilaster, Smooth Stucco
Finish,
Color: Omega #10
3.4" x 2" Reclaimed Wood
Rail
4.Finished Surface
1 2
6'3'2761
Legend
1.Smooth Stucco Finish,
Color: Omega #10
2.Custom Mailbox with House
Numbers,
Designer to Source
3.Concrete Cap, Smooth Sand Finish
Topcast #3, Davis Color 'Miami Buff'
4.Adjacent Fence. See Pilaster and
Fence Elevation
5.Finish Surface
2
5
Mailbox Elevation
Scale: 12" = 1'
431
Pool Wall and Entry Gate Elevation
Scale: 12" = 1'
21
House Facing Elevation6'Legend
1.6' Ht Wall, Smooth Stucco
Finish,
Color: Omega #10
2.(3x) Water Weirs, Designer to
Source
3.Pool Below
4.6" Vertical Wood Plank Entry
Gate
5.Finished Surface
6.Tile Finish, Size & Color: TBD
7.Adjacent Property Line Wall
3 4576
Vine Espalier Elevation
Scale: 1 2" = 1'
1.Adjacent Wall
2.Steel Wires with
Eye Hooks
3.Vine, Ref. Sheet L-2
4.Finished Grade
Legend1
4
3 2
Side Gate & Fence Elevation
Scale: 12" = 1'
1.Wood Gate, 6" Vertical Paint Grade
Wood, Painted White
2.Wood Fence, 6" Vertical Paint
Grade Wood, Painted White
3.Emtek 'Rectangular Helios Key in
Leverset' Gate Lever with Latch
and Strike Plate
4.(3x) Emtek 4" x 4" x 14" Heavy Duty
Ball Bearing Hinge
5.Finish Surface
Legend21345
5'
SJ SJ SJ SJ SJ
RIRIM
M
M
M
M
M
M
M
M
M
M
M
BL1BL1BL1
WB
WB RIS
P
P
BG1
O
BG1
BL1
BG1WB LA O
P O
WB LALA
C1BG1BG1
WBGBGBPP
SY P O SY C1
BG1 O
GB
O
BG1
GB
BG1
O
RI
RI
S
GB
BG1
O
LA
LA
MLMLMLMLMLMLRI
RI
S
GB
O
LA
SSJ
SJSY
SY
P
P
P
P O
BG1
BG1BG1
LA
LT
LT
LT
LT
LT
LT
LT
LT
LT
LT
LT
LT
45°
45°
45°
45°
45°45°
45°
45°
Media
Dining
Kitchen
Entry
Laundry
Powder
Golf Cart
Garage
Trash
Storage
BAYSHORE DRIVE10' Front Setback10' Rear Setback
4' SideSetback4' SideSetbackALLEY10' Rear Setback
2' HOA Front
Setback
Lighting Legend:
Symbol Description Product #Finish Type Qty
Path Lights GSD-14-1-MBR Matte Bronze 12v LED 08
Regular Uplights GSD-11-1-MBR 05
Small Uplights GSD-11-2-MBR
Matte Bronze
Matte Bronze
12v LED
12v LED 06
Contractor to Field Verify All
Measurements and Confirm
Details to Provide Accurate Bid
2732 East Coast Highway, Suite A
Corona Del Mar, CA 92625
949.673.5450
Date:
Revisions:
SCALE: 1/8" =1'-0"
0'2'4'8'16'SPANOS RESIDENCE2761 Bayshore Drive, Newport Beach, CA 9266308.29.2022 - Initial Meeting
Drawn By:
Sheet:
PM:
Contact Email:
ashley@gardenstudiodesign.com
RP
AS
08.23.2022ARDENST
U
DI
OD
E S I G NG08.30.2022 - HOA Submittal
09.27.2022 - HOA Submittal
L-4
Lighting Plan
45°
45°
45°
45°
45°45°
45°
45°
Media
Dining
Kitchen
Entry
Laundry
Powder
Golf Cart
Garage
Existing Residence
Breakfast Breakfast Dining
Ultra Heavy (Architecture, Walls, Tall Site Furniture: Fire Places, Chimneys)
Heavy (Low Retaining Walls, Pool Tops, Lower Site Furniture: BBQ's, Fire Pits)
Trash
Storage
BAYSHORE DRIVEALLEYW
EXISTING
DOMESTIC
WATER
METER
EXISTING
DOMESTIC
HOUSE LINE
MV
A A
A
A
A
F
FF
F
F SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSA2
1"
1
HZ 2
85 SF
A1
1"
7
HZ 1
140 SF
A4
1"
3
HZ 3
274 SF
A3
1"
3
HZ 2
288 SF
A5
1"
1
HZ 2
114 SF
A6
1"
1
HZ 2
79 SF
A
SSSSSSSSSSSSSSSLO-CLOSE SERIES BALL VALVE. SIZE per LINE
A
IRRIGATION CONTRACTOR TO VERIFY CONTROLLER LOCATION. POWER
SUPPLY CONNECTION TO THE IRRIGATION CONTROLLER SHALL BE THE
RESPONSIBILITY OF THE IRRIGATION CONTRACTOR.
WATER METER EXISTING DOMESTIC WATER METER. CONTRACTOR TO FIELD VERIFY LOCATION
AND ADEQUATE PRESSURE PRIOR TO COMMENCING IRRIGATION WORK.
NO SYMBOL INSTALL WIRELESS RAIN-CLIK and CONNECT to CONTROLLER. INSTALL
PER MANUFACTURER'S SPECIFICATIONS.
LASCO
IRRIGATION
CONTROLLER
HUNTER
HEAVY DUTY HOSE BIB. PER CONTRACTOR. IRRIGATION CONTRACTOR TO
COORDINATE FINAL LOCATIONS WITH HOMEOWNER PRIOR TO INSTALLATION.HUNTER
PVC PIPE SCH. 40 SLEEVING, TWICE THE DIAMETER OF PIPE OR
WIRE BUNDLE CARRIED - EXTEND 12" BEYOND EDGE OF PAVING &
PLACE BELOW ALL PAVING, HARDSCAPE, ETC..
1 12" IRRIGATION PRESSURE MAINLINE SCH. 40 PVC - BURY MIN. 18"
BELOW GRADE. with SCHEDULE 80 FITTINGS
NON-PRESSURE LATERAL SCH 40 PVC with SCHEDULE 40 FITTINGS
UP TO 1 12" - BURY MIN. 12" BELOW GRADE (SIZE AS NOTED ON PLAN).
AS APPROVED
AS APPROVED
AS APPROVED
GPMVAL.#
SIZE TYPE
Sq. Ft.
NO SYMBOL
IRRIGATION UTILITIES & VALVES
IRRIGATION CONTROLLER
IRRIGATION PIPING
VALVE KEY
DRIPLINE AUTOMATIC LINE FLUSH VALVE. - PROVIDE SCH 40 SOLVENT- WELD
BALL VALVE FOR FLUSH OFF OF PCV EXHAUST MANIFOLD PIPE, INSTALL FLUSH
VALVE INSIDE 6" ROUND VALVE BOX, ONE AT THE END OF ANY DRIPLINE
LATERAL or PVC EXHAUST HEADER. MULTIPLE FLUSH VALVES MAY BE
REQUIRED WITHIN DRIPLINE LAYOUT. ALWAYS INSTALL VALVES IN OPPOSITE
DIRECTIONS OF THE PVC/DRIP CONNECTION MANIFOLD.
USE HUNTER FITTINGS FOR CONNECTION BETWEEN PVC LATERAL LINES AND
DRIPPERLINE TUBING.
NON-PRESSURE LATERAL SCH. 40 SUPPLY LATERAL. NOTE: EXHAUST
LATERALS NOT SHOWN.
PLD-ARV-075 AIR/VACUUM RELIEF VALVE INSTALLED with COMBINATION TEE AND A
3/4" x 1/2" REDUCER BUSHING, INSTALL AIR RELIEF ASSEMBLY INSIDE A 6" ROUND
VALVE BOX AT THE HIGH POINT OF EACH PLANTER, MIN. 1 ARV PER 500' OF
DISTRIBUTION TUBING. USING AIR RELIEF LATERAL, CONNECT AIR RELIEF VALVE
TO ALL DRIPPERLINE LATERALS WITHIN THE ELEVATED AREA.
MULTIPLE ARV'S SHALL BE REQUIRED PER RCV WITHIN UNDULATING AREAS,
VERIFY QUANTITY PRIOR TO STARTING WORK, FLUSH VALVES and AIR RELIEF
VALVES SHOWN DIAGRAMMATICALLY, INSTALL EMITTER BOX:
18" MIN. FROM PAVING/WALLS AND AT HIGH POINTS OF
PLANTER AREA.
PCZ-101 AND ACZ-075. 1" AND 3
4" ANTI-SIPHON REMOTE CONTROL VALVES
FILTER SYSTEM.
HUNTER - HDL-06-12 SUB-SURFACE DRIPLINE TUBING 0.6 GPH EMITTERS at 12"
ON CENTER SPACING- ALL TUBING SHALL BE INSTALLED 4" MINIMUM BELOW
FINISHED SOIL GRADE W/ 9" WIRE STAKES FIVE (4) FEET ON CENTER; VERIFY
THE LAYOUT AND 12" MIN. ON CENTER SPACING IN THE FIELD PRIOR TO
STARTING WORK. INSTALL SUB-SURFACE DRIP IRRIGATION SYSTEM per
MANUFACTURER'S SPECIFICATIONS.
A
SUB-SURFACE DRIP IRRIGATION
PIPE SIZE
BLANK TUBING or 1/2" PVC0 - 5 GPM
ZONE FLOW
8.1 - 13 GPM
1 1/2" PVC
5 - 8 GPM 3/4" PVC
1 1/4" PVC13.1 - 22 GPM
22.1 - 30 GPM
1" PVC
LATERAL, MAINLINE & DRIPPERLINE SUPPLY/EXHAUST PIPE SIZING:
HUNTER
AS APPROVED
NETAFIM
HUNTER
ICV-101G - REMOTE CONTROL VALVE with FLOW CONTROLHUNTER
SSSSIRRIGATION LEGEND
F
AS APPROVED NON-PRESSURE UVR LATERAL SCH 40 PVC with SCHEDULE 40
FITTINGS UP TO 1 12" - ON GRADE, PROVIDE PIPE STABILIZERS 10'
O.C. (SIZE AS NOTED ON PLAN).
INSTALL ALL NOZZLES AND BUBBLERS LISTED BELOW ON PRO-6-PRS40-CV FOR
TURF AREAS AND PRO-12-PRS40-CV FOR SHRUB AREAS. USE PCS SCREENS
FOR HEADS WITH OVERSPRAY ONTO HARDSCAPE. ALL HEADS ON LOWEST
POINTS OF ZONES TO BE INSTALLED WITH HUNTER HCV CHECK VAVLES
SPRAY AND BUBBLER IRRIGATION
HUNTER
PCB BUBBLERS - 2' to 4' RADIUS (0.5 GPM), INSTALL (2) BUBBLERS PER TREEHUNTER
NO SYMBOL
AS APPROVEDNO SYMBOL
NO SYMBOL SPEARS
DBY DIRECT BURIAL WATER-PROOF WIRE CONNECTORS FOR USE ON ALL
WIRE CONNECTIONS
IRRIGATION CONTROL WIRE #14UF AWG DIRECT BURIAL (U.L. APPROVED)
DS-400 PRE-FILLED WIRE CONNECTORS FOR USE ON ALL WIRE CONNECTIONS
NO SYMBOL 3M
FOR IRRIGATION DETAILS SEE SHEETS L-6 and L-7
FOR IRRIGATION SPECIFICATIONS SEE SHEET L-8
REFERENCE NOTES
IRRIGATION MISCELLANEOUS EQUIPMENT
EXISTING MAINLINE TO REMAIN
MV HUNTER IBV-101G-FS MASTER VALVE
Contractor to Field Verify All
Measurements and Confirm
Details to Provide Accurate Bid
2732 East Coast Highway, Suite A
Corona Del Mar, CA 92625
949.673.5450
Date:
Revisions:SPANOS RESIDENCE2761 Bayshore Drive, Newport Beach, CA 9266308.29.2022 - Initial Meeting
Drawn By:
Sheet:
PM:
Contact Email:
ashley@gardenstudiodesign.com
RP
AS
08.23.2022ARDENST
U
DI
OD
E S I G NG08.30.2022 - HOA Submittal
09.27.2022 - HOA Submittal
L-5
Irrigation Plan
Contractor to Field Verify All
Measurements and Confirm
Details to Provide Accurate Bid
2732 East Coast Highway, Suite A
Corona Del Mar, CA 92625
949.673.5450
Date:
Revisions:SPANOS RESIDENCE2761 Bayshore Drive, Newport Beach, CA 9266308.29.2022 - Initial Meeting
Drawn By:
Sheet:
PM:
Contact Email:
ashley@gardenstudiodesign.com
RP
AS
08.23.2022ARDENST
U
DI
OD
E S I G NG08.30.2022 - HOA Submittal
09.27.2022 - HOA Submittal
L-6
Irrigation Notes
GENERAL IRRIGATION NOTES
1.IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROCURE AN ORIGINAL SET OF THESE PRINTED IRRIGATION PLANS FOR BIDDING
AND CONSTRUCTION. COPIES OF THESE PLANS ARE NOT ALLOWED FOR BIDDING AND CONSTRUCTION AS THEY MAY NOT SHOW IRRIGATION
SYMBOLS, LINE WEIGHTS, OR LINE TYPES CLEARLY.
2.ALL LOCAL MUNICIPAL AND STATE LAWS, RULES AND REGULATIONS GOVERNING OR RELATING TO ANY PORTION OF THIS WORK ARE HEREBY
INCORPORATED INTO AND MADE A PART OF THESE SPECIFICATIONS AND THEIR PROVISIONS SHALL BE CARRIED OUT BY THE CONTRACTOR.
3.THE CONTRACTOR SHALL VERIFY SITE CONDITIONS, PROPERTY LINES, DIMENSIONS AND THE LOCATIONS OF ALL EXISTING UTILITIES,
STRUCTURES AND SERVICES BEFORE COMMENCING WORK. THE LOCATIONS OF UTILITIES, STRUCTURES AND SERVICES SHOWN IN THESE
PLANS ARE APPROXIMATE ONLY. ANY DISCREPANCIES BETWEEN THESE PLANS AND ACTUAL FIELD CONDITIONS SHALL BE REPORTED TO THE
OWNER'S REPRESENTATIVE. CONTRACTOR SHALL THOROUGHLY FAMILIARIZE HIMSELF WITH ALL SITE CONDITIONS PRIOR TO BIDDING AND
COMMENCING WORK.
4.THE CONTRACTOR SHALL OBTAIN THE PERTINENT ENGINEERING OR ARCHITECTURAL PLANS BEFORE BEGINNING WORK.
5.THE CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS REQUIRED TO PERFORM THE WORK INDICATED HEREIN BEFORE BEGINNING WORK.
6.THIS DESIGN IS DIAGRAMMATIC. ALL EQUIPMENT SHOWN IN PAVED AREAS IS FOR DESIGN CLARITY ONLY AND IS TO BE INSTALLED WITHIN
PLANTING AREAS.
7.THE CONTRACTOR SHALL NOT WILLFULLY INSTALL ANY EQUIPMENT AS SHOWN ON THE PLANS WHEN IT IS OBVIOUS IN THE FIELD THAT
UNKNOWN CONDITIONS EXIST THAT WERE NOT EVIDENT AT THE TIME THESE PLANS WERE PREPARED. ANY SUCH CONDITIONS SHALL BE
BROUGHT TO THE ATTENTION OF THE OWNER'S REPRESENTATIVE PRIOR TO ANY WORK OR THE IRRIGATION CONTRACTOR SHALL ASSUME ALL
RESPONSIBILITY FOR ANY FIELD CHANGES DEEMED NECESSARY BY THE OWNER.
8.INSTALL ALL EQUIPMENT AS SHOWN IN THE DETAILS AND SPECIFICATIONS. CONTRACTOR SHALL BE RESPONSIBLE TO COMPLY WITH LOCAL
CITY, COUNTY AND STATE REQUIREMENTS FOR BOTH EQUIPMENT AND INSTALLATION.
9.ACTUAL LOCATION FOR THE INSTALLATION OF THE BACKFLOW PREVENTION DEVICE AND THE AUTOMATIC CONTROLLER IS TO BE DETERMINED
IN THE FIELD BY THE OWNER'S AUTHORIZED REPRESENTATIVE.CONTRACTOR SHALL CONTACT REPRESENTATIVE BEFORE COMMENCING WORK.
10.CONTRACTOR IS TO PROVIDE TWO ADDITIONAL 'CONTROL WIRES' AND ONE ADDITIONAL 'COMMON' WIRE FROM CONTROLLER ALONG ENTIRETY
OF MAIN LINE TO THE LAST RCV ON EACH AND EVERY LEG OF MAIN LINE. LABEL SPARE WIRES AT BOTH ENDS.
11.ALL PIPE UNDER PAVED AREAS TO BE INSTALLED IN SLEEVING TWICE THE DIAMETER OF THE PIPE CARRIED. SEE LEGEND FOR TYPE. ALL WIRE
UNDER PAVED AREAS TO BE INSTALLED IN A SCH. 40 SLEEVE THE SIZE REQUIRED TO EASILY PULL WIRE THROUGH. ALL SLEEVES TO BE
INSTALLED WITH A MINIMUM DEPTH AS SHOWN ON THE SLEEVING DETAILS. SLEEVES TO EXTEND AT LEAST 12" PAST THE EDGE OF THE PAVING.
12.ALL QUICK COUPLERS TO BE INSTALLED IN SHRUB OR GROUND COVER AREAS WHERE POSSIBLE. ALL QUICK COUPLERS TO BE INSTALLED AS
SHOWN ON THE INSTALLATION DETAILS. INSTALL ALL QUICK COUPLERS WITHIN 18" OF HARDSCAPE.
13.ALL HEADS ARE TO BE INSTALLED WITH THE NOZZLE, SCREEN AND ARCS SHOWN ON THE PLANS. ALL HEADS ARE TO BE ADJUSTED TO PREVENT
OVERSPRAY ONTO BUILDINGS, WALLS, FENCES AND HARDSCAPE. THIS INCLUDES, BUT NOT LIMITED TO, ADJUSTMENT OF DIFFUSER PIN OR
ADJUSTMENT SCREW, REPLACEMENT OF PRESSURE COMPENSATING SCREENS, REPLACEMENT OF NOZZLES WITH MORE APPROPRIATE RADIUS
UNITS AND THE REPLACEMENT OF NOZZLES WITH ADJUSTABLE ARC UNITS.
14.THE CONTRACTOR SHALL USE U.L. APPROVED GROUND ROD(S) AND/OR GROUND PLATE(S) WITH CADWELD ONE-SHOT CONNECTION PROCESS
FOR CONNECTING THE CONDUCTOR WIRE TO THE ROD(S) AND/OR PLATE(S).
15.THE NUMBER OF RODS OR PLATES SHALL DEPEND ON THE CONDUCTIVITY OF THE IMMEDIATE SOIL SURROUNDING THE ROD(S) AND/OR
PLATE(S). MAXIMUM GROUND RESISTANCE SHALL BE PER CONTROLLER MANUFACTURERS SPECIFICATIONS.
16.CONTRACTOR SHALL REFER TO IRRIGATION LEGEND FOR CONTROLLER TYPE. FINAL LOCATION OF CONTROLLER AND ELECTRICAL POC SHALL
BE CONFIRMED WITH OWNER'S AUTHORIZED REPRESENTATIVE PRIOR TO COMMENCING WORK.
17.MAINLINE SHOWN WITHIN PAVING FOR CLARITY ONLY, ACTUAL MAINLINE LOCATION TO BE WITHIN PLANTER, A MINIMUM OF 18" OFF ADJACENT
HARDSCAPE AND OTHER OBSTACLES TYP.
18.CONTRACTOR SHALL PAINT ALL EXPOSED PVC PIPE WHICH IS ON-GRADE TO REDUCE VISIBILITY TO THE PUBLIC EYE AND IMPROVE THE
AESTHETICS OF THE NATURAL ENVIRONMENT. PAINT SHALL BE AN OUTDOOR PAINT RESISTANT TO SUN EXPOSURE. CONTRACTOR SHALL
CONFIRM PAINT COLOR AND TYPE WITH OWNER'S AUTHORIZED REPRESENTATIVE PRIOR TO COMMENCING WORK.
19.LATERAL LINES MAY BE SHOWN WITHIN PAVING FOR CLARITY ONLY, ACTUAL LOCATION TO BE WITHIN PLANTER. CONFIRM ALL LAYOUT IN FIELD
WITH OWNER'S AUTHORIZED REPRESENTATIVE PRIOR TO COMMENCING WORK.
20.REMOTE CONTROL VALVES AND ISOLATION VALVE LOCATIONS ON THIS DRAWING ARE APPROXIMATE. THE LANDSCAPE CONTRACTOR SHALL
STAKE OUT EACH ELECTRICAL CONTROL VALVE AND ISOLATION VALVE LOCATION FOR REVIEW AND APPROVAL BY OWNER'S AUTHORIZED
REPRESENTATIVE PRIOR TO INSTALLATION OF ALL VALVES. FINAL LOCATION AND EXACT POSITIONING FOR ELECTRIC CONTROL VALVES AND
ISOLATION VALVES SHALL BE DETERMINED BY THE OWNER'S AUTHORIZED REPRESENTATIVE. MINOR MODIFICATIONS OF REMOTE CONTROL
VALVES AND ISOLATION VALVE LOCATIONS AS REQUESTED BY THE OWNER'S AUTHORIZED REPRESENTATIVE SHALL BE PROVIDED BY THE
CONTRACTOR AT NO ADDITIONAL COST TO THE PROJECT. FAILURE TO OBTAIN OWNER'S APPROVAL PRIOR TO THE INSTALLATION SHALL CAUSE
THE CONTRACTOR TO MAKE PROJECT DIRECTED REVISIONS AT NO ADDITIONAL COST TO THE OWNER. IN GENERAL, UNLESS OTHERWISE
DIRECTED BY OWNER, ALL VALVES SHALL BE INSTALLED WITHIN THREE FEET FROM EDGE OF HARDSCAPE, WALK OR CURB IN SHRUB PLANTING
AREAS.
21.THE CONTRACTOR SHALL USE PROPER GROUNDING TECHNIQUES FOR GROUNDING THE CONTROLLER AND RELATED EQUIPMENT PER
MANUFACTURERS SPECIFICATIONS. MEASURING FOR PROPER GROUND AT LEAST ONCE ANNUALLY, AND NECESSARY ADJUSTMENTS MADE TO
COMPLY WITH MANUFACTURER SPECIFICATIONS IS RECOMMEND.
PRESSURE LOSS CALCULATION
·
·
·
·
·
IRRIGATION CONTROLLER SCHEDULE
TOTAL SYSTEM LOSS:
P.O.C. #
FRICTION LOSS CALCULATIONS
FLOW METER
CONTROL VALVE
MASTER VALVE
METER ELEV.
H.G.L.
PSI
PSI
PSI
PSI
WATER METER NO.
ELEVATION
SIZE
STATIC PRESS.HIGH LOW
INFO. SOURCE:
PHONE:
DATE OF INFO.
.433 =X
REMOTE CONTROL VALVE No.SIZE
MAX. DEMAND GPM
ELEV. OF HIGHEST HEAD
PRESS. AT RCV PSI
QTY.SIZE
PRESS. REGULATOR (FALL OFF)PSI
WATER METER PSI
BACKFLOW PREVENTER PSI
GATE VALVE PSI
MAINLINE PSI
MAINLINE PSI
MAINLINE PSI
MAINLINE PSI
LATERAL LINE
LATERAL LINE
LATERAL LINE
PSI
PSI
PSI
LATERAL LINE PSI
FITTING LOSS (10%)PSI
ELEVATION CHANGE (+/-)PSI
PRESSURE TO OPERATE HEAD PSI
TOTAL PRESSURE REQUIRED:PSI
LOWEST STATIC PRESSURE AVAILABLE PSI
PRE-SET REGULATED PRESSURE (IF REQ'D)PSI
RESIDUAL WATER PRESSURE PSI
-
-3/4"
N/A
±±
-
-
-
N/A
-
--
A1 1"
7
-
-
1 3/4"3.5
---
---
1 -0.1
1 -0.5
1 LINE 0.5
226 -2.2
---
---
---
1 1"4.1
---
-1 1/4"-
±1"-
±3/4"0.3
1.1
-
12.3
40
52.3
-
-
10-15
MAXIMUM DEMAND
PLANT WATER REQ.
A HYDROZONE TREE / SHRUB / GROUNDCOVER
B REFERENCE PERIOD 31 DAYS
C REFERENCE Eto 5.3 INCHES
D LANDSCAPE CO: K 0.60
1 PLANT FACTOR: K 0.60
2 VEGE. DENSITY 1.00
3 MICROCLIMATE 1.00
E LANDSCAPE ET 3.18 INCHES
F AVERAGE DAILY ET 0.103 INCHES
IRRI PERFORMANCE VALUE UNITS
G PRECIP RATE 0.600 IN./HR.
H DISTRIB. UNIFORMITY 0.65 DECIMAL
I SCHEDULE MULTIPLIER 1.60
SCHEDULING
PARAMETERS
J IRRIGATION INTERVAL 3.5 DAYS
K WATER TO APPLY 0.36 INCHES
L LOWER BOUNDARY 36 MINUTES
M UPPER BOUNDARY 57 MINUTES
N SELECTED RUN TIME 57 MINUTES
O CYCLE STARTS:
a TIME TO RUNOFF N/A
OR b SITE CONDITION 2 CYCLES
1 SOIL CATEGORY 2 -
2 SLOPE 0 -
3 COMPACTION 0 -
4 SPRINKLER TYPE 0 -
SUMMARY
WATER APPLIED 0.36 INCHES
INTERVAL 3.5 DAYS
CYCLES PER DAY 2
MINUTES PER CYCLE 29 MINUTES
THESE IRRIGATION SCHEDULES ARE FOR TWICE WEEKLY IRRIGATION PER CITY OF NEWPORT BEACH
REQUIREMENTS. THE UPPER BOUNDARY IRRIGATION RUN TIME HAS BEEN SELECTED FOR THE INITIAL
PLANT ESTABLISHMENT PERIOD (MINIMUM ONE YEAR). ONCE PLANTS ARE ESTABLISHED THE RUN
TIMES MAY BE SHORTENED TO THE LOWER BOUNDARY. ROUTINE PLANT OBSERVATION AND
MAINTENANCE ARE REQUIRED FOR OPTIMAL PLANT HEALTH.
VALUE UNITS
VALUE UNITS
VALUE UNITS
THIS IRRIGATION SYSTEM HAS BEEN DESIGN FOR A
PRESSURE OF 65 PSI. IF THE WATER PRESSURE
VARIES BY MORE THAN 20% THE CONTRACTOR SHALL
CONTACT THE LANDSCAPE ARCHITECT ON HOW TO
PROCEED. FAILURE TO DO SO WILL ALL
REPAIRS/REPLACEMENTS ON THE RESPONSIBILITY
OF THE CONTRACTOR.
MAR.JAN FEB.APR.MAY JUN.JUL.DEC.AUG.SEP.NOV.OCT.
= 45.4
C.I.M.I.S. STATION: NEWPORT BEACH
ET DATA MONTHLYo 2.6 2.5 3.5 4.2 5.0 4.7 5.3 5.3 4.5 3.3 2.5 2.0
IRRIGATION SCHEDULE SAMPLE: JULY 5.3 ETo for DRIP
Hydrozones (by r.c.v. station):
MAXIMUM APPLIED WATER ALLOWANCE and ESTIMATED APPLIED WATER USE CALCULATIONS:
= (45.4) x (.62) [(0.55 x 960) + ((1-.55) x 0)]=
M.A.W.A
MAWA = (ETo) (0.62) [(0.55 x LA) + ((1-ETAF) x SLA)]EAWU = (ET ) x (Plant Factor) x (Hydrozone Area) x (.62)
Irrigation Efficiency (72% - 90%)
E.A.W.U. - SEE TABLE BELOW
o
14,862 gallons/year
14,579 gallons/year
RCV STATION ETO PLANT FACTOR HYDROZONE
AREA (SQ. FT.)CONV. FACTOR IRRIGATION EFFICIENCY Gallons/Year
HZ1 45.4 140 0.62
HZ2 0.62SHRUB DRIP
0.4 81%
81%
1,751TREE WITH BUBBLERS
WATER USE
MED
TOTAL 14,579
=
54645.4MED 0.4 6,830
HZ3 0.62TURF DRIP 81%27445.4HIGH 0.7 5,998
Rev 02/14/17
NOTICE OF
APPLICATION FILING
THE PLANNING DIVISION OF THE COMMUNITY DEVELOPMENT DEPARTMENT OF
THE CITY OF NEWPORT BEACH RECENTLY RECEIVED A COASTAL
DEVELOPMENT PERMIT APPLICATION FOR THE FOLLOWING PROJECT:
PROPOSED PROJECT: Demolition of an existing 2,200 SF single family residence
and attached garage and construction of a 1,977 SF two (2)-story single family
residence with an attached 669 SF two (2)-car garage and a 616 SF upper level terrace.
______________________________________________________________________
______________________________________________________________________
LOCATION: 2761 Bay Shore Drive _________________________________________
______________________________________________________________________
______________________________________________________________________
APPLICANT: Hayer Architecture ___________________________________________
APPLICATION NO.: PA2022-0214___________________________________________
DATE NOTICE POSTED: __________________________________________________
The public hearing for this application has not yet been scheduled. When the hearing, or
determination are scheduled, further notice will be provided.
The application is available for your review at the Community Development Department
Permit Center (Bay C-1st Floor), at 100 Civic Center Drive, Newport Beach, California, CA
92660. Prior to the public hearing, the agenda, staff report, and documents may be
reviewed. For more information, call (949) 644-3200 (please reference the application
number).
City of Newport Beach CDP Information & Requirements - Page 8 of 14
(Posted: 03-02-2018)
Tmplt: 06/07/19
P ROJECT R EVIEW R EQUES T
C O M M U N I T Y D E V E L O P M E N T D E P A R T M E N T
Planning Division
Please Distribute to:
Building – Tonee Thai
Public Works – David Keely
Fire – Kevin Bass
Date: October 5th, 2022
Please return PRR and Plans to Staff Planner
Jenny Tran, Assistant Planner
949-644-3212, jtran@newportbeachca.gov
Applicant:
Hayer Architecture Contact: Troy Weiland
(858) 792-2800
TWeiland@hayerarchitecture.com
Project Name Spanos Residence
Address: 2761 Bay Shore Drive
PA2022-0214 Coastal Development Permit
Demolish an existing single-family residence and construct a new 1,977 square-foot single-family
residence with an attached 669 square-foot 2-car garage, and 616 square-foot upper-level terrace.
REPORT REQUESTED BY: October 17, 2022
Zoning Administrator: Hearing Date: TBD
Check all that apply:
❑ No comments on the project
as presented.
Notes:
1) Comply with liquefaction mitigation requirement.
2) Comply with Pool/Spa Safety requirement.
3) 3 feet minimum deep door landing required on both sides for
doors.
4)
Tonee Thai 1867 10-25-2022
Signature Ext. Date
X Application of Standard Code
requirements are not expected to
alter the project design.
❑ Recommended conditions of
approval are attached.
❑ Application of Standard Code
requirements or the attached
conditions of approval will
substantially impact or alter
the design of the project.
❑ I contacted the applicant on
❑ To schedule an appt. for
Code review
❑ To discuss the following
(see notes)
Tmplt: 06/07/19
P ROJECT R EVIEW R EQUES T
C O M M U N I T Y D E V E L O P M E N T D E P AR T M E N T
Planning Division
Please Distribute to:
Building – Tonee Thai
Public Works – David Keely
Fire – Kevin Bass
Date: October 5th, 2022
Please return PRR and Plans to Staff Planner
Jenny Tran, Assistant Planner
949-644-3212, jtran@newportbeachca.gov
Applicant:
Hayer Architecture Contact: Troy Weiland
(858) 792-2800
TWeiland@hayerarchitecture.com
Project Name Spanos Residence
Address: 2761 Bay Shore Drive
PA2022-0214 Coastal Development Permit
Demolish an existing single-family residence and construct a new 1,977 square-foot single-family
residence with an attached 669 square-foot 2-car garage, and 616 square-foot upper-level terrace.
REPORT REQUESTED BY: October 17, 2022
Zoning Administrator: Hearing Date: TBD
Check all that apply:
❑ No comments on the project
as presented.
Notes:
Fire sprinklers are required for the new residence
A 3-foot wide fire department access way is required along one side
yard from the street to the alley
Kevin Bass 3108 10/12/22
Signature Ext. Date
❑ Application of Standard Code
requirements are not
expected to alter the project
design.
❑ Recommended conditions of
approval are attached.
❑ Application of Standard Code
requirements or the attached
conditions of approval will
substantially impact or alter
the design of the project.
❑ I contacted the applicant on
❑ To schedule an appt. for
Code review
❑ To discuss the following
(see notes)