HomeMy WebLinkAboutPA2022-0187_20220826_Plans_42x30DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
SHEET LISTCODE INFORMATIONSITE INFORMATIONPROJECT STATISTICSDEFERRED SUBMITTALSPROJECT DESCRIPTION
VICINITY MAP SPECIAL INSPECTIONS SHORING & EXCAVATION AGENCIES & SERVICES PROJECT DIRECTORY
13
24
57
68
911
10 BRANDONARCHITECT
STRUCTURAL ENGINEER
INTERIOR DESIGNER
ENERGY CONSULTANT
BRANDON ARCHITECTS, INC.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
P: 714.454.4040
WWW.BRANDONARCHITECTS.COM
OWNER
CIVIL ENGINEER
LANDSCAPE DESIGNER
MEP CONSULTANT
GENERAL CONTRACTOR
GEOTECHNICAL ENGINEER
SURVEYORARCHITECTS, INC.BRANDON ARCHITECTS
2/16/2022
TITLE SHEETHEDGE RESIDENCEEDDIE AND DESIREE HEDGE
1400 W. BAY AVENUE
NEWPORT BEACH, CA 92661
DD
1400 W. BAY AVENUE
T-1.0
HEDGE RESIDENCE
1400 W. BAY AVENUE
**0000-2021**
JEFF VAN VOORHIS
EDDIE AND DESIREE HEDGE
1400 W. BAY AVENUE
NEWPORT BEACH, CA 92661
TBD
EGA CONSULTANTS, INC.
375-C MONTE VISTA AVENUE
COSTA MESA, CA 92627
T: 949.642.9309
APEX LAND SURVEYING, INC.
17853 SANTIAGO BLVD, SUITE 107-285
VILLA PARK, CA 92861
T: 714.488.5006
TBDDEJAGER DESIGN INC.
4040 MACARTHUR BLVD., SUITE 350
NEWPORT BEACH, CA 92660
T: 949.463.3987
PMA CONSULTING, INC.
28161 CASITAS CT.
LAGUNA NIGUEL, CA 92677
T: 714.717.7542
CIVILSCAPES ENGINEERING, INC.
28052 CAMINO CAPISTRANO, SUITE 213
LAGUNA NIGUEL, CA 92677
T: 949.464.8115
TBD GREGORY DESIGN
4 SHETLAND
TRABUCO CANYON, CA 92679
T: 949.888.9511
BUILDING AREA SHCEDULE
LEVEL AREA COMMENTS
FIRST FLOOR 1428 SF
SECOND FLOOR 2114 SF
THIRD FLOOR 364 SF
3906 SF
GARAGE 501 SF
501 SF
GRAND TOTAL 4407 SF
OUTDOOR AREA SCHEDULE
NAME AREA COMMENTS
LEGAL DESCRIPTION:
LOT INFORMATION:
ZONED: R-1 SINGLE-UNIT RESIDENTIAL
SITE AREA:3,889 S.F. BUILDABLE AREA: 2,321.8 S.F.
TOTAL ALLOWABLE AREA: 2 X 2,321.8 S.F. = 4,643 S.F.
REQ'D. OPEN VOLUME = 2,321.8 S.F. X .15 = 348.27 S.F. (7'-6" HT. MIN.)
TOTAL ALOWABLE THIRD FLOOR AREA = XXXXX S.F.
EXISTING BUILDING INFORMATION:
EXISTING SINGLE FAMILY W/ GARAGE TO BE DEMOLISHED
EXISTING S.F. = 1,921 S.F. (3 BEDS. TTL.)
ZONING INFORMATION:
FRONT SETBACK: 5 FT.
REAR SETBACK: 25 FT.
LEFT SETBACK: 3 FT.
RIGHT SETBACK: 3 FT.
APN: 047-221-11
LOT 12 BLOCK 1 OF CITY OF NEWPORT BEACH, COUNTY OF ORANGE,
STATE OF CALIFORNIA
CODES:NBMC (NEWPORT BEACH MUNICIPAL CODE)
2019 CRC, 2019 CFC, 2019 CEC, AND 2019 CMC
CALGREEN AND 2019 CAL. ENERGY CODE
OCCUPANT LOAD 1 UNIT
OCCUPANCY CLASSIFICATION R-3/U
OCCUPANCY SEPARATION (GARAGE)1-HR.
FLOOR & FLOOR-CEILING N/A.
TYPE OF CONSTRUCTION VB -SPRINKLERED
FIRE SPRINKLER YES
HEIGHT 3 -LEVELS
FLOOR AREA REF. 7/T-1.0
ALLOWABLE BLDG. ARE (PER CBC TBL. 503)N/A.
DIG ALERT:1.800.227.2600
SOUTHERN CALIFORNIA EDISON:1.714.895.0246
SOUTHERN CALIFORNIA GAS:1.800.427.2000
CITY WATER & SEWER:1.949.644.3011
PACIFIC BELL TELEPHONE:1.800.750.2355
CITY OF NEWPORT BEACH
PUBLIC WORKS DEPT.:1.949.644.3311
CITY OF NEWPORT BEACH PLANNING DEPT.:
GENERAL INFOMATION:1.949.644.3200
ZONING INFORMATION:1.949.644.3204
CITY OF NEWPORT BEACH BUILDING DEPT.:
GENERAL:1.949.644.3275
PERMITS:1.949.644.3288
INSPECTIONS:1.949.644.3255
NEWPORT BEACH FIRE DEPARTMENT:1.949.644.3106
ORANGE COUNTY HEALTH SERVICES:1.714.834.3882
1.A CAL-OSHA PERMIT IS REQUIRED FOR EXCAVATIONS DEEPER THAN 5' AND FOR SHORING AND UNDERPINNING. CONTRACTOR TO
PROVIDE A COPY OF OSHA PERMIT.
2.CONTRACTOR SHALL USE THE CITY STANDARD FORM '30-DAY NOTICE OF INTENT TO EXCAVATE' TO NOTIFY ADJACENT PROPERTY
OWNERS BY CERTIFIED MAIL 30-DAYS PRIOR TO STARTING EXCAVATION OR SHORING. CITY STANDARD FORM CAN BE OBTAINED AT:
HTTP://WWW.NEWPORTBEACHCA.GOV/HOME/SHOWDOCUMENT?ID=17395
1.REF. STRUCTURAL DRAWINGS FOR SPECIAL INSPECTIONS BY ENGINEER OF RECORD
2.HERS VERIFCATION REQUIRED, REF. ENERGY CALCULATIONS
1. LANDSCAPE PLAN; BBQ; FIRE PIT; ACCESSORY STRUCTURES, MASONRY OR CONCRETE WALLS/FENCES; RETAINING WALLS OVER 4 FT.
HIGH FROM THE BOTTOM OF THE FOUNDATION TO THE TOP OF WALL; UNDER SEPERATE REVIEWS AND PERMITS (FOR H.O.A.
PURPOSES).
2. POOLS, SPAS, WALLS, FENCES, PATIO COVERS AND OTHER FREESTANDING STRUCTURES REQUIRE SEPARATE REVIEWS AND PERMITS.
3. SUBMIT SOUND ATTENUATION DESIGN FOR HVAC EQUIPMENT PER ARI STD. 275. SOUND LEVEL NOT TO EXCEED 50dBA (55dBA WITH
TIMER, 65dBA WITH TIMER AND NEIGHBORS CONSENT). LOCATION OF MEASUREMENT TO BE AT ADJACENT PROPERTY PATIO OR
OPENING.
4. FIRE SPRINKLERS REQUIRED, CONSTRACTOR TO SUBMIT FIRE SPRINKLER DRAWINGS FOR ARCHITECT'S APPROVAL PRIOR TO
SUBMITTING TO CITY. OBTAIN FIRE SPRINKLER PERMIT PRIOR TO CALLING FOR ROOF SHEATHING INSPECTION.
5. A NOTICE OF INTENT TO DEMOLISH SHALL BE SENT VIA CERTIFIED MAIL TO ADJACENT PROPERTY OWNER(S). SIGNED RETURNED
RECEIPT MUST BE PROVIDED TO THE BUILDING DIVISION AT THE TIME OF PERMIT ISSUANCE. DEMOLITION MAY COMMENCE 30 DAYS
AFTER THE DATE OF NOTIFICATION PER NEWPORT BEACH MUNICIPAL CODE SECTION 15.02.120.
6. PV SOLAR SYSTEM (MIN. 4.3KW DC) + 5 KWH BATTERY SYSTEM PER T-24
7. ELEVATOR
NOTE: DEFERRED SUBMITTALS TO BE REVIEWED BY PROJECT ARCHITECT OR ENGINEER OF RECORD AND CERTIFIED PRIOR TO
SUBMITTAL TO LOCAL AGENCY FOR REVIEW.
C.N.B. NOTE: BRANDON ARCHITECTS, INC. IS THE DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE OF THE PROJECT, RESPONSIBLE FOR
REVIEWING AND COORDINATING SUBMITTAL DOCUMENTS PREPARED BY OTHERS, INCLUDING PHASED AND DEFERRED SUBMITTAL
ITEMS, FOR COMPATIBILITY WITH THE DESIGN OF THE BUILDING. (NBMC 12.02.010)
THE SUBJECT PROPERTY IS LOCATED IN NEWPORT BEACH, CA IN THE AREA KNOWN AS THE BALBOA PENINSULA WITH BEACH FRONTAGE
ON WEST OCEAN FRONT. THE LOT IS APPX. 40' WIDE BY APPX. 90' DEEP, IT IS ZONED R-1 (SINGLE-UNIT RESIDENTIAL) AND IS APPX 3,652
S.F. DEVELOPMENT OF THE PROPERTY WILL BE REVIEWED BY THE CITY OF NEWPORT BEACH FOR BUILDING AND COASTAL DVELOPMENT
PERMITS. THE PROPERTY INCLUDES AN EXISTING SINGLE FAMILY RESIDENCE AND GARAGE. CLIENT PROPOSES TO DEMOLISH EXISTING
IMPROVEMENTS AND BUILD A NEW 3-STORY SINGLE FAMILY RESIDENCE OF APPX. 3,900 S.F. WITH A TWO-CAR GARAGE OF APPX. 500
S.F. THE PROGRMA MAY INCLUDE BUT NOT BE LIMITED TO THE FOLLOWING: LARGE EAT-IN KITCHEN W/. ISLAND & PANTRY, GREAT
ROOM WITH A FIREPLACE, DINING AREA (OPEN AREA), POWDER ROOM, ELEVATOR, MASTER SUITE WITH FIREPLACE, MASTER BATH,
WALK-IN CLOSE, 3 SECONDARY BEDROOMS WITH ATTACHED BATHS & CLOSETS, LAYNDRY ROOM, SMALL BAR & WINE STORAGE AREA,
AND BONUS ROOM WITH ATTACHED BATH & CLOSET ON THE THIRD FLOOR. THERE WILL BE A LARGE ROOF DECK WITH COVERED
CABANA. THE YARD AND DECK AREAS WILL BE ARRANGED WITH A STRONG CONNECTION TO INDOOR LIVING SPACE AND AMENITIES
MAY INCLUDE A FIRE FEATURE, BBQ AREA, AND OUTDOOR COVERED LOUNG AREA. THE PROJECT WILL BE OF A WARM CONTEMPORARY
DESIGN FEATURING AMPLE /ONDOOR/OUTDOOR LIVING SPACES INTEGRATED WITH A MODERN 'OPEN' LIVING PLAN WITH LOTS OF
GLAZING TO MAXIMIZE OCEAN VIEW FROM LIVING SPACES AS WELL AS OUTDOOR PATIOS, DECKS, AND ROOF DECKS.
T-1.0 TITLE SHEET
T-1.1 ARCHITECTURAL GENERAL NOTES
SUR TOPOGRAPHIC SURVEY
C1 TITLE SHEET
C2 GRADING PLAN
C3 EROSION CONTROL PLAN
C4 GEOTECHNICAL NOTES
L- 0 LANDSCAPE PLANTING PLAN
A-0.0 ARCHITECTURAL SITE PLAN
A-0.1 SLAB EDGE PLAN
A-0.2 AREA PLANS
A-1.0 3D VIEWS
A-2.0 FIRST & SECOND LEVEL FLOOR PLANS
A-2.1 THIRD LEVEL FLOOR PLAN
A-2.2 FIRST & SECOND LEVEL DIMENSION PLANS
A-2.3 THIRD LEVEL DIMENSION PLAN
A-3.0 ROOF PLAN
A-4.0 EXTERIOR ELEVATIONS
NO. REVISION DATE
PROJECT SITE
SUBTOTAL
SUBTOTAL
PA2022-0187
DEFINITIONS: (AS USED IN THESE SPECIFICATIONS)
OWNER SHALL MEAN: EDDIE AND DESIREE HEDGE
ARCHITECT SHALL MEAN: BRANDON ARCHITECTS, INC., JEFF VANVOORHIS*
CONTRACTOR SHALL MEAN:LICENSED GENERAL CONTRACTOR HIRED TO PERFORM THE WORK UNDER THIS CONTRACT
SPECIFICATIONS SHALL MEAN:WRITTEN SPECIFICATIONS IN THE PLANS OR THE "PROJECT MANUAL" (IF PROVIDED FOR THIS PROJECT)
CONTRACT DOCUMENTS SHALL MEAN: WORKING DRAWINGS APPROVED FOR BUILDING PERMIT, PLUS ANY CHANGE ORDERS OR ADDENDA TO SAME.
ARCHITECTURAL GENERAL NOTES:
1. CODES/GENERAL PROVISIONS: ALL WORK, CONSTRUCTION AND MATERIALS SHALL COMPLY WITH ALL PROVISIONS OF THE APPLICABLE BUILDING CODES AND WITH OTHER RULES, REGULATIONS AND ORDINANCES GOVERNING THE PLACE OF
CONSTRUCTION. IT IS THE RESPONSIBILITY OF THE CONTRACTOR, SUB-CONTRACTORS, AND ANYONE SUPPLYING LABOR AND/OR MATERIAL TO BRING TO THE ATTENTION OF THE ARCHITECT (VERBALLY AND IN WRITING) ANY KNOWN DISCREPANCIES OR
CONFLICT BETWEEN THE REQUIREMENTS OF THESE CODES AND THE CONTRACT DOCUMENTS (DRAWINGS). THE APPLICABLE CODES SHALL INCLUDE, BUT SHALL NOT BE LIMITED TO THOSE AS LISTED IN "CODE REVIEW" BOX. (T-1.0)
ALL WORK SHALL BE PERFORMED SO AS TO COMPLY WITH ALL LEGAL AND INDUSTRY REQUIREMENTS AND STANDARDS INCLUDING THE FOLLOWING:
-THE CALIFORNIA BUILDING CODES, 2019 EDITIONS, AND ALL APPLICABLE RELATED SPECIALTY CODES.
-THE FUNCTIONALITY STANDARDS SET FORTH IN TITLE 7 OF THE CALIFORNIA CIVIL CODE (THE "RIGHT TO REPAIR ACT").
-THE CITY OF NEWPORT BEACH MUNICIPAL CODE INCLUDING ANY WORK TIME RESTRICTION AND ANY AMENDMENT TO CALIFRONIA BUILDING CODES.
-THE MANUFACTURER'S REQUIREMENTS OF RECOMMENDATIONS FOR ANY INCORPORATED PRODUCTS.
2. FEES: CONTRACTOR AND HIS SUB-CONTRACTORS SHALL OBTAIN AND PAY FOR ALL PERMITS, LICENSES, CONSTRUCTION TAXES AND FEES REQUIRED BY CITY, COUNTY AND STATE LAWS EXCEPT THE GENERAL BUILDING PLAN CHECK FEE AND REQUIRED
REFUNDABLE DEPOSITS WHICH WILL BE PAID BY THE OWNER. CONTRACTOR SHALL ARRANGE FOR ALL METER INSTALLATIONS AND PAY ALL FEES FOR SAID METERS. CONTRACTOR SHALL PROVIDE TEMPORARY TOILET FACILITIES AND EROSION CONTROL
MEASURES AS REQUIRED BY STATE AND LOCAL BUILDING CODE.
3. CONTRACTOR'S SURVEY: CONTRACTOR SHALL VISIT THE JOB SITE AND BE RESPONSIBLE FOR HAVING COMPLETE KNOWLEDGE OF EXISTING CONDITIONS. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS WITH THOSE SHOWN ON THE DRAWINGS AND
SHALL VERIFY GRADES, CONDITIONS AND DIMENSIONS PRIOR TO COMMENCING DEMOLITION AND CONSTRUCTION. CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY VERBALLY AND IN WRITING OF DISCREPANCIES BETWEEN ACTUAL CONDITIONS AND
THOSE DEPICTED IN THE CONTRACT DOCUMENTS. CONTRACTOR SHALL NOTIFY ARCHITECT IMMEDIATELY VERBALLY AND IN WRITING OF ANY DISCREPANCIES FOUND WITHIN THE DRAWINGS AND SPECIFICATIONS.
4. COORDINATION OF CONSTRUCTION: CONTRACTOR IS SOLELY RESPONSIBLE FOR THE ACCURACY OF DETAILS; FOR CONFIRMING AND COORDINATING ALL QUANTITIES AND DIMENSIONS; FOR SELECTING FABRICATION PROCESSES; FOR TECHNIQUES OF
ASSEMBLY AND PERFORMANCE OF ALL WORK IN A SAFE AND SATISFACTORY MANNER. CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF ALL WORK INCLUDING THAT OF THE SUB-CONTRACTORS. CONTRACTOR SHALL PROVIDE SUPERVISION OF
THE JOB DURING ALL PHASES OF CONSTRUCTION ACTIVITIES. A COMPETENT SUPERINTENDENT SHALL BE SELECTED BY THE CONTRACTOR AND SHALL BE IN CHARGE OF THE JOB UNTIL ITS COMPLETION. CONTRACTOR AGREES TO BIND EVERY SUB-
CONTRACTOR BY THE TERMS OF THE CONTRACT AS FAR AS SUCH TERMS ARE APPLICABLE TO THE SUB-CONTRACTOR'S WORK.
5. CLEAN-UP: ALL SUBCONTRACTORS SHALL BE RESPONSIBLE FOR THE DAILY REMOVAL OF ALL DEBRIS ACCUMULATED AS A RESULT OF THEIR OPERATIONS. ALL SCRAP DEBRIS AND OTHER EXCESS MATERIAL SHALL BE LAWFULLY REMOVED FROM THE SITE,
UNLESS OTHERWISE DIRECTED BY THE CONTRACTOR.
6. TESTS AND PERMITS: CONTRACTOR SHALL ARRANGE FOR, AND SECURE REQUIRED TESTS, PERMITS AND INSPECTIONS, AND SHALL BEAR COSTS FOR SAME.
7. GUARANTEES: CONTRACTOR SHALL GUARANTEE ALL WORK, MATERIALS AND PRODUCTS FOR ONE YEAR AFTER THE DATE OF ACCEPTANCE OF THE WORK AND CONTRACTOR SHALL REPAIR OR REPLACE, OR CAUSE TO BE REPAIRED OR REPLACED ANY OR ALL
SUCH WORK TOGETHER WITH ANY OTHER WORK WHICH MAY BE DISPLACED IN DOING SO, THAT MAY PROVE DEFECTIVE WITHIN ONE YEAR, WITHOUT ADDITIONAL EXPENSE; ORDINARY WEAR AND TEAR, UNUSUAL ABUSE OR NEGLECT IS EXCEPTED. EXCEPTIONS
TO ONE YEAR GUARANTEE ARE SPECIFIED IN OTHER SECTIONS OF THE PROJECT MANUAL OR DRAWINGS. STATE LAW, OR MANUFACTURER'S GUARANTEE SHALL GOVERN IF LENGTH AND TYPES OF GUARANTEES ARE MORE STRICT OR FOR LONGER PERIODS. IT IS
UNDERSTOOD BY CONTRACTOR THAT IT IS HIS RESPONSIBILITY TO PROVIDE MATERIALS AND CONSTRUCTION WHICH WILL YIELD A REASONABLE VALUE OVER A PERIOD OF TIME WHICH MAY EXCEED THE SPECIFIED GUARANTEE AND WARRANTY PERIODS.
CONTRACTOR SHALL BE RESPONSIBLE FOR A WEATHER TIGHT BUILDING, FREE FROM DEFECTS OF MATERIALS AND WORKMANSHIP. EACH SUB-CONTRACTOR SHALL PROVIDE A WRITTEN GUARANTEE STATING THAT WORK EXECUTED BY HIM IS FREE AND WILL
REMAIN FREE FROM DEFECTS OF MATERIALS AND WORKMANSHIP FOR ONE YEAR FROM DATE OF ACCEPTANCE OF HIS WORK BY OWNER, AND THAT REPAIR AND REPLACEMENT OF SUCH DEFECTIVE WORK AND ALL OTHER WORK DAMAGED AS A RESULT THEREBY
WILL BE EXECUTED IN A TIMELY MANNER AT THE CONVENIENCE OF THE OWNER AND WITHOUT COST TO OWNER.
8. WAIVER OF LIENS: CONTRACTOR SHALL PROVIDE CERTIFIED RELEASE OF LIENS BY ALL SUBCONTRACTORS AND SUPPLIERS, OR ANYONE PROVIDING MATERIALS AND/OR LABOR AS THEY BECOME AVAILABLE.
9. ROLL OF ARCHITECT DURING CONSTRUCTION: THE ARCHITECT WILL NOT ACT AS THE OWNER'S REPRESENTATIVE DURING CONSTRUCTION. ARCHITECT WILL ADVISE AND CONSULT WITH OWNER. ARCHITECT WILL OBSERVE CONSTRUCTION PER HIS/HER
AGREEMENT WITH OWNER AND RENDER INTERPRETATIONS NECESSARY FOR THE PROPER EXECUTION OR PROGRESS OF THE WORK IN ACCORDANCE WITH THE INTENT OF THE PLANS AND SPECIFICATIONS. ARCHITECT WILL NOT BE RESPONSIBLE OR HAVE
CONTROL OR CHARGE OVER THE ACTS OR OMISSIONS, CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS, OF THE CONTRACTOR, SUB-CONTRACTORS, OR ANY OF THEIR AGENTS OR
EMPLOYEES, OR ANY OTHER PERSONS PERFORMING ANY OF THE WORK. ANY VERBAL INSTRUCTION OR AUTHORIZATION THAT IS CONFIRMED BY LETTER, MEETING NOTE, MEMORANDA, OR THE LIKE, (WITH A COPY SENT TO THE OWNER, OR THE OWNER'S
REPRESENTATIVE) & THERE IS NO EXCEPTION TAKEN WITHIN (10) CALENDAR DAYS, SHALL BE DEEMED EQUIVALENT TO RECEIPT OF WRITTEN INSTRUCTION, APPROVAL AND AUTHORIZATION FROM THE OWNER.
10. A.I.A. GENERAL CONDITIONS: THE CURRENT GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION PUBLISHED BY THE AMERICAN INSTITUTE OF ARCHITECTS SHALL APPLY AS THOUGH IT WERE PART OF THESE DOCUMENTS UNLESS SPECIFICALLY
MODIFIED IN THE OWNER/CONTRACTOR AGREEMENT. A COPY OF SAID GENERAL CONDITIONS MAY BE OBTAINED FROM THE ARCHITECT UPON REQUEST. THE NOTES CONTAINED IN THESE "GENERAL NOTES" ON THIS SHEET ARE INTENDED TO SUMMARIZE AND
COMPLIMENT THE A.I.A. GENERAL CONDITIONS. THE A.I.A. GENERAL CONDITIONS SHALL TAKE PRECEDENCE OVER THESE NOTES SHOULD A CONFLICT IN WORDING OCCUR.
11. EXTRAS: OWNER MAY ORDER EXTRA WORK OR MAKE CHANGES BY ALTERING, ADDING TO OR DEDUCTING FROM THE WORK, THE CONTRACT SUM BEING ADJUSTED TO THE MUTUAL SATISFACTION OF THE OWNER AND CONTRACTOR. BEFORE ANY CHANGES
ARE BEGUN, THE ADDED OR DEDUCTED SUM SHALL BE PRESENTED TO OWNER IN WRITING FOR APPROVAL.
12. SUBSTITUTIONS: SUBSTITUTIONS OF MATERIALS OR METHODS PROPOSED BY THE CONTRACTOR OR HIS SUB-CONTRACTORS CONTRARY TO DRAWINGS AND SPECIFICATIONS SHALL BE SUBMITTED TO ARCHITECT IN WRITING FOR APPROVAL OR DENIAL. IF
MORE THAN ONE MANUFACTURER IS SPECIFIED IN THE PLANS OR SPECIFICATIONS, IT SHALL BE THE CONTRACTOR'S OPTION TO SELECT THE ONE WHICH HE MAY DESIRE. IF MORE THAN ONE FINISH OR STYLE IS AVAILABLE IN THE ITEM SPECIFIED, CONTRACTOR
SHALL BE OBLIGATED TO NOTIFY ARCHITECT VERBALLY AND IN WRITING OF THIS FACT FOR ARCHITECT'S AND OWNER'S DECISION. WHERE THE TERM "OR EQUAL" IS USED IN DRAWINGS OR SPECS IT SHALL BE UNDERSTOOD THAT THE REFERENCE IS MADE
SUBJECT TO THE RULING AND JUDGMENT OF THE ARCHITECT AND SHALL BE SUBMITTED TO THE ARCHITECT FOR REVIEW AND APPROVAL. ACTUAL SAMPLES OF THE SUBSTITUTIONS SHALL ALSO BE SUBMITTED TO THE ARCHITECT FOR REVIEW AND APPROVAL.
13. INSURANCE: CONTRACTOR SHALL CARRY GENERAL LIABILITY INSURANCE WITH BROAD FORM PROPERTY DAMAGE ENDORSEMENT AND CONTINGENT LIABILITY ENDORSEMENT. OWNER AND ARCHITECT SHALL BE LISTED AS ADDITIONAL INSURERS UNDER
THE POLICY WITH WAIVER OF SUBROGATION. CONTRACTOR SHALL FURNISH OWNER WITH A CERTIFICATE OF INSURANCE WITH A 30 DAY NOTICE OF CANCELLATION. OWNER SHALL OBTAIN A BUILDER'S RISK POLICY WITH ARCHITECT NAMED AS AN ADDITIONAL
INSURED WITH WAIVER OF SUBROGATION.
14. SCOPE OF DRAWINGS AND SPECIFICATIONS: THESE DRAWINGS AND SPECIFICATIONS SHALL BE INTENDED TO SHOW AND DESCRIBE DETAILS FOR A CONSTRUCTIBLE BUILDING. PARTS AND DETAILS NOT FULLY SHOWN OR DESCRIBED SHALL BE DETAILED
AND EXECUTED ACCORDING TO STANDARD FIRST CLASS PRACTICE AND IN SIMILAR MANNER AND SPIRIT OF THE DETAILS WHICH ARE SHOWN ON THE DRAWINGS AND/OR DESCRIBED IN THE PROJECT MANUAL. IF CONTRACTOR OR SUB-CONTRACTOR FINDS ANY
DETAILS WHICH, IN HIS OPINION, ARE UNSOUND, UNSAFE, OR NOT WATERPROOF, IT IS HIS DUTY TO NOTIFY ARCHITECT IN WRITING OF THIS FACT. IF WORK IS PERFORMED AS DETAILED, IT WILL BE ASSUMED THAT THERE ARE NO OBJECTIONS TO THE DETAIL.
ACCURACY OF ALL DIMENSIONS SHALL BE CHECKED. NO EXTRA COMPENSATION WILL BE ALLOWED FOR DIFFERENCE BETWEEN ACTUAL DIMENSIONS AND THOSE INDICATED ON THE DRAWINGS. IN USING THESE PLAN FOR BIDDING OR CONSTRUCTION
PURPOSES, ALL CONTRACTORS ARE REQUIRED TO REVIEW AND TREAT THEM AS A WHOLE IN ORDER TO IDENTIFY ALL REQUIREMENTS THAT DIRECTLY OR INDIRECTLY AFFECT THEIR PORTION OF THE WORK, EVEN REQUIREMENTS LOCATED IN SECTIONS
DESIGNATED AS APPLICABLE TO OTHER TRADES. IN CASE OF CONFLICTS, THE AFFECTED CONTRACTOR IS REQUIRED TO EITHER OBTAIN DIRECTION FROM AN APPROPRIATE REPRESENTATIVE OF THE OWNER, OR OTHERWISE TO APPLY THE MORE STRINGENT
STANDARD. THESE PLANS ARE INTENDED TO SET FORTH THE REQUIREMENTS FOR CONSTRUCTION IN ONLY AN INDUSTRY-STANDARD LEVEL OF QUALITY AND DETAIL, AND THEY ARE INTENDED TO BE SUPPLEMENTED BY APPROPRIATE REQUESTS FOR
CLARIFICATION AND INFORMATION. ERRORS AND OMISSIONS ARE TO BE EXPECTED AND ANTICIPATED, AND ALL CONTRACTORS ARE REQUIRED TO CAREFULLY REVIEW THESE PLANS FOR ERRORS AND OMISSIONS AND TO BRING THESE ERRORS AND OMISSIONS
TO THE ATTENTION OF A APPROPRIATE OWNER & ARCHITECT IN WRITING IN A TIMELY MANNER; AND ANY CONTRACTOR WHO FAILS TO DO SO BEFORE BIDDING OR OTHERWISE PROCEEDING ASSUMES THE RISK OF ANY CONSEQUENCES. SCALED DIMENSIONS
SHOULD BE CONSIDERED ONLY APPROXIMATE; AND IN ANY DIMENSIONS BEFORE PROCEEDING WITH ANY AFFECTED PROCUREMENT, FABRICATION OR CONSTRUCTION. SCHEMATIC PLANS ARE INTENDED ONLY TO DEMONSTRATE THE RELATIONSHIP AMONG
COMPONENT PARTS, AND NOT TO DEPICT SPECIFIC LOCATIONS (E.G. SCHEMATIC ELECTRICAL PLANS).
15. DIMENSIONS ON DRAWINGS: FIGURED DIMENSIONS SHALL BE FOLLOWED IN PREFERENCE TO SCALE, AND DETAIL DRAWINGS IN PREFERENCE TO SMALL SCALE DRAWINGS. SUB-CONTRACTOR AND CONTRACTOR SHALL CHECK ACCURACY OF ALL
DIMENSIONS IN THE FIELD PRIOR TO ANY WORK BEING CONSTRUCTED OR MATERIALS OR PRODUCTS FABRICATED OR ORDERED. SPECIFICATIONS AND WRITTEN NOTES AND SCHEDULES ON DRAWINGS SHALL BE FOLLOWED IN PREFERENCE TO INFORMATION
FURNISHED IN THE FORM OF LINE DRAWINGS. DETAILED DRAWINGS FURNISHED DURING CONSTRUCTION OR APPROVED BY CONTRACTOR OR ARCHITECT ARE TO BE CONSIDERED EXPLANATORY AND NOT AS CHANGES TO DRAWINGS AND SPECIFICATIONS.
NOTES, FIGURES AND DETAILS ON SAID DRAWINGS SHALL BE FOLLOWED AND EXECUTED AS IF PART OF THESE DOCUMENTS. DRAWINGS ARE NOT TO BE SCALED UNLESS PERMITTED BY THE ARCHITECT. DIMENSIONS SHALL GOVERN. ALL EXTERIOR
DIMENSIONS ARE BASED ON NOMINAL SIZES OF MEMBERS AND ARE GIVEN TO THE OUTER FACE OF SUCH MEMBERS, UNLESS OTHERWISE NOTED ON DRAWINGS. INTERIOR PARTITIONS ARE DIMENSIONED FROM FACE OF STRUCTURE TO FACE OF STRUCTURE
UNLESS OTHERWISE NOTED ON DRAWINGS. WHERE DIMENSION IS LABELED "CLEAR" IT IS TAKEN FROM THE FACE OF FINISH TO FACE OF FINISH OF EACH MATERIAL. PLUS OR MINUS (+/-) DIMENSIONS SHALL NOT VARY BY MORE THAN 2" WITHOUT APPROVAL
BY ARCHITECT. WALL ANGLES ARE EITHER 90° OR 45° UNLESS NOTED OTHERWISE.
16. SUBMITTALS, MEETING NOTES, BULLETINS, AND MEMOS: SUBMITTALS WILL BE REVIEWED BY THE ARCHITECT, IF AT ALL, ONLY PURSUANT TO THE INDUSTRY-STANDARD PROTOCOL SET FORTH IN AIA DOCUMENT A201-2017; AND IN NO EVENT WILL THE
SUBMITTAL REVIEW PROCESS RELIEVE OR LESSEN THE SUBMITTING CONTRACTOR'S RESPONSIBILITY FOR AN INAPPROPRIATE SUBMITTAL. ARCHITECT, FROM TIME TO TIME, WILL ISSUE CONSTRUCTION NOTES OR MEMOS REGARDING CONSTRUCTION ISSUES
THAT HAVE ARISEN SINCE THE DRAWINGS AND SPECIFICATIONS WERE COMPLETED. CONTRACTOR SHALL REVIEW THESE WRITTEN DOCUMENTS AND INCORPORATE THEM INTO THE PROJECT. ANY QUESTIONS OR OBJECTIONS AS TO THE INTENT OF THE WRITTEN
DOCUMENT ITEMS WILL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT FOR DISCUSSION AND OR CLARIFICATION. ANY ITEM THAT RESULTS IN A CHANGE TO THE COST OR TIMING OF THE PROJECT SHALL BE BROUGHT TO THE IMMEDIATE
ATTENTION OF THE OWNER & ARCHITECT PRIOR TO EXECUTING. CONTRACTOR SHALL SUBMIT FABRICATION SHOP DRAWINGS TO THE ARCHITECT FOR APPROVAL PRIOR TO ORDERING AND/OR FABRICATION. CONTRACTOR SHALL SUBMIT MANUFACTURER'S CUTS
FOR ALL FIXTURES AND EQUIPMENT CALLED FOR ON THE CONSTRUCTION DOCUMENTS TO ARCHITECT INCLUDING BUT NOT LIMITED TO LIGHT FIXTURES, HARDWARE, PLUMBING FIXTURES, KITCHEN EQUIPMENT, ETC. BY SUBMITTING SHOP DRAWINGS AND
PRODUCT DATA, THE CONTRACTOR REPRESENTS THAT HE/SHE HAS VERIFIED FIELD CONDITIONS, DIMENSIONS AND RELATED CONSTRUCTION AND HAS COORDINATED THE SUBMISSION CONSTRUCTION WITH THE REQUIREMENTS OF ALL OTHER RELATED WORK IN
THE CONSTRUCTION DOCUMENTS. ALL SHOP DRAWINGS AND CUTS MARKED "REVIEWED" BY ARCHITECT, ARE FOR VERIFICATION OF ADHERENCE TO THE DESIGN INTENT ONLY. THE CONTRACTOR SHALL ASSUME RESPONSIBILITY FOR ALL MEANS AND METHODS
AND ERRORS AND OMISSIONS ON THEIR DRAWINGS. CONTRACTOR TO SUBMIT A COMPLETE SHOP DRAWINGS AND OR SUBMITTAL FOR APPROVAL BEFORE COMMENCING FABRICATION AND/OR INSTALLATION OF ALL APPLICABLE ITEMS. ALL SHOP DRAWINGS
DIMENSIONS SHALL BE FIELD VERIFIED, REVIEWED AND APPROVED BY CONTRACTOR BEFORE SUBMITTAL. SHOP DRAWINGS WHICH ARE INCOMPLETE OR LACKING SUFFICIENT INFORMATION WILL BE RETURNED WITHOUT REVIEW. SUBMIT SAMPLES FOR INITIAL
SELECTION PURPOSES OF ACTUAL VENEERS SHOWING A FULL RANGE OR GRAIN VARIATION, FINISH AND PATTERNS PROPOSED. SUBMIT SAMPLES AS REQUIRED UNTIL APPROVED BY ARCHITECT. SAMPLES SHALL BE 12" X 12" MIN., ONE UNIT OF EACH TYPE
AND FINISH.
17. ERRORS AND OMISSIONS: ERRORS OR OMISSIONS WHICH APPEAR ON THE DRAWINGS, IN SPECIFICATIONS OR OTHER CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT BY THE CONTRACTOR AND TO THE
CONTRACTOR BY THE SUB-CONTRACTOR IN WRITING. IN EVENT OF FAILURE OF SUB-CONTRACTOR TO GIVE SUCH WRITTEN NOTIFICATION BEFORE CONSTRUCTION OR FABRICATIONS OF THE WORK, HE WILL BE HELD RESPONSIBLE FOR THE RESULTS OF ANY SUCH
ERRORS OR OMISSIONS AND THE COSTS OF RECTIFYING SAME. HOWEVER, DRAWINGS AND SPECIFICATIONS ARE COMPLEMENTARY AND WORK CALLED FOR ON ONE AND NOT THE OTHER SHALL BE PROVIDED AS THOUGH FULLY SET FORTH IN BOTH.
18. BARRICADES: CONTRACTOR SHALL ERECT AND PROPERLY MAINTAIN AT ALL TIMES AS REQUIRED BY CONDITIONS AND PROGRESS OF THE WORK, ALL NECESSARY PROTECTIVE BARRICADES, FENCES AND OTHER SAFEGUARDS FOR THE PROTECTION OF THE
WORKERS AND THE PUBLIC. THESE BARRICADES SHALL BE CONSTRUCTED AND BE LOCATED AS SHALL BE DETERMINED BY LOCAL AUTHORITIES AND CODES.
19. TEMPORARY BRACING: AT ALL TIMES DURING CONSTRUCTION ACTIVITIES OR ERECTION OF PROJECT OR ITS COMPONENT PARTS, PRIOR TO COMPLETION OF THE STRUCTURAL FRAME OR REPLACEMENT AND PERMANENT CONNECTION OF COMPONENT
MEMBERS TO THE STRUCTURAL FRAME, SUB-CONTRACTORS SHALL PROVIDE, INSTALL AND MAINTAIN PROPERLY DESIGNED AND CONSTRUCTED TEMPORARY BRACING OF ADEQUATE STRENGTH TO PREVENT DISLOCATION, DISTORTION, CRACKING, FALLING OFF,
OR ANY OTHER DAMAGE TO WORK OR ANY OF ITS COMPONENT PARTS DUE TO FORESEEABLE NORMAL AS WELL AS NOT FORESEEABLE EXCESSIVE WIND AND EARTHQUAKE FORCES WITHOUT ADDITIONAL COST TO OWNER. CONTRACTOR AND HIS
SUBCONTRACTORS SHALL, AT THEIR EXPENSE, REPLACE OR REPAIR, AS DIRECTED, DAMAGED PORTIONS OF THEIR WORK OR COMPONENT PARTS.
20. TOXIC SUBSTANCES REMOVAL: PRIOR TO ANY WORK BEING PERFORMED, WHENEVER THERE ARE EXISTING STRUCTURES TO BE REMOVED OR ALTERED, CONTRACTOR SHALL BE RESPONSIBLE FOR THE LOCATION AND REMOVAL OF ANY TOXIC MATERIALS OR
SUBSTANCES AS REQUIRED BY THE STATE OF CALIFORNIA INCLUDING BUT NOT LIMITED TO ASBESTOS, LEAD PAINTS, MOLD, ETC. REMOVAL AND DISPOSAL SHALL FOLLOW STATE MANDATED METHODS, PROCEDURES, DOCUMENTATION AND APPLICATION
REQUIREMENTS.
21. NO CHANGES ARE TO BE MADE ON THESE PLANS WITHOUT THE KNOWLEDGE OR CONSENT OF THE ARCHITECT/ ENGINEER WHOSE SIGNATURE APPEARS HERON.
22. NO FRAMING OF ANY TYPE TO BE CONCEALED PRIOR TO INSPECTION BY GOVERNING AGENCIES.
23. REFERENCES TO ANY DETAIL OR DRAWINGS IS FOR CONVENIENCE ONLY AND DOES NOT LIMIT THE APPLICATION OF SUCH DETAIL OR DRAWINGS.
24. USE 2X6 MINIMUM STUDS FOR PLUMBING WALLS
25. MAINTENANCE INFORMATION: THE BUILDER SHALL PROVIDE TO THE BUILDING OWNER AT OCCUPANCY MAINTENANCE INFORMATION FOR ALL FEATURES, MATERIALS, COMPONENTS, AND MANUFACTURED INFORMATION FOR ALL FEATURES, MATERIALS, AND
COMPONENTS AND MANUFACTURED DEVICES THAT REQUIRE ROUTINE MAINTENANCE FOR EFFICIENT OPERATION. REQUIRED ROUTINE MAINTENANCE ACTIONS SHALL BE CLEARLY STATED AND INCORPORATED ON A READILY ACCESSIBLE LABEL. THE LABEL MAY
BE LIMITED TO IDENTIFYING, BY TITLE AND/OR PUBLICATION NUMBER, THE OPERATION AND MAINTENANCE MANUAL FOR THAT PARTICULAR MODEL AND TYPE OF FEATURE, MATERIAL, COMPONENT, OR MANUFACTURED DEVICE. (SEE CALGREEN NOTES FOR
ADDITIONAL REQUIREMENTS OF OPERATION & MAINTENANCE MANUAL)
26. GENERAL CONTRACTOR, CONTRACTORS, SUB-CONTRACTORS AND BUILDERS TO COORDINATE ALL ENGINEERING AND MECHANICAL DRAWINGS WITH ARCHITECTURAL DRAWINGS BEFORE PROCEEDING WITH WORK. IF DISCREPANCIES ARE APPARENTLY
OBSERVED OR INFORMATION APPARENTLY IS THOUGHT TO BE MISSING, NOTIFY ARCHITECT WITHIN 24 HOURS WITH SKETCH, DRAWING, PDF, PHOTOCOPIES WITH LEGIBLE HANDWRITTEN NOTES AND/OR WRITING (FAX, EMAIL OR CORRESPONDENCE). IF CONFLICT
WITH EXISTING CONDITIONS, PROVIDE DOCUMENTATION (PHOTOS, SKETCHES, DWGS) OF EXISTING CONDITIONS AND SUGGEST PROPOSAL(S) FOR SOLUTION (SKETCH, DRAWING, AND/OR WRITING). IN CASE OF ANY DISCREPANCIES, THE ARCHITECT IS THE SOLE
INTERPRETER OF THE CONTRACT DOCUMENTS.
27. CONTRACTOR SHALL NOTIFY ARCHITECT FOR CLARIFICATION PRIOR TO BIDDING OF ANY DISCREPANCIES BETWEEN ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS. BID SHALL BE BASED ON THE MOST STRINGENT REQUIREMENT.
28. CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT OF ANY UNEXPECTED OR UNKNOWN FIELD CONDITIONS, ERRORS, OMISSIONS, OR DISCREPANCIES IN THE DRAWINGS, PROJECT MANUAL, OR CONTRACT DOCUMENTS PRIOR TO PROCEEDING WITH
THE WORK OR SHOP FABRICATIONS.
29. CONTRACTOR SHALL PREPARE AND MAINTAIN ALL CONSTRUCTION, AND SURROUNDING AREAS, FREE OF DEBRIS OR HAZARDOUS MATERIALS AT ALL TIMES. CONTRACTOR SHALL TAKE NECESSARY PRECAUTIONS TO PREVENT DUST FROM RISING.
30. CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR AND/OR THE REPLACEMENT OF ANY ITEMS DAMAGED DURING CONSTRUCTION OR CLEAN-UP. ANY DAMAGE TO EXISTING STRUCTURES DURING THE CONSTRUCTION OR THE NEW WORK SHALL BE
REPAIRED TO EQUIVALENT OR BETTER THAN ORIGINAL CONDITION AT CONTRACTOR'S EXPENSE.
31. ALL OSHA REGULATIONS FOR CONSTRUCTION AREAS SHALL BE STRICTLY FOLLOWED. CONTRACTOR SHALL PROVIDE PROPER SAFEGUARDS DURING ALL PHASES OF CONSTRUCTION.
32. CONTRACTOR TO REMOVE, RELOCATE OR RE-ROUTE, AS NECESSARY, ELECTRICAL, TELEPHONE, WATER, SEWER, GAS OR ANY OTHER UTILITY LINES ENCOUNTERED AND SHALL COORDINATE THIS WORK WILL ALL LOCAL UTILITY COMPANIES.
33. CONTRACTOR SHALL PROVIDE TEMPORARY WEATHER PROTECTION FOR PORTIONS OF THE WORK THAT BECOME EXPOSED TO WEATHER AND SHALL BE RESPONSIBLE FOR DAMAGE CAUSED BY INSUFFICIENT PROTECTION.
34. CONTRACTOR TO OBTAIN WRITTEN APPROVAL FROM OWNER AND ARCHITECT PRIOR TO ANY CHANGES OR DEVIATION FROM CONTRACT DOCUMENTS.
35. CONTRACTOR SHALL SUBMIT IN WRITING ALL PROPOSALS FOR ADDITIONAL WORK TO THE OWNER FOR REVIEW AND APPROVAL. NO WORK IS TO PROCEED UNTIL AN AUTHORIZATION TO PROCEED; SIGNED BY THE ARCHITECT & OWNER'S REPRESENTATIVE IS
RETURNED TO THE GENERAL CONTRACTOR.
36. CONTRACTOR SHALL BE AWARE THAT SPECIFIC FIRE-RATED SEPARATION WITHIN THE BUILDING'S CONSTRUCTION IS REQUIRED BY CODE. THE USE OF SPECIFIC MATERIALS AND COMBINATION OF MATERIALS WITHIN FIRE RATED ASSEMBLIES, AS CALLED
FOR ON THE DRAWINGS AND SPECIFICATIONS, ARE FOR THE PURPOSE OF ACHIEVING THOSE REQUIRED FIRE SEPARATIONS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THAT ANY CHANGE IN MATERIAL THAT IS REQUESTED BY OR MADE BY THE
CONTRACTOR AND/OR ITS SUBCONTRACTORS, FROM THOSE MATERIALS DRAWN OR SPECIFIED, DOES NOT IN ANY WAY AFFECT OR LESSEN THE REQUIRED CONSTRUCTION ASSEMBLY INTEGRITY. SPECIFIC SEQUENCES OR METHODS OF ACHIEVING FIRE RATED
ASSEMBLIES REQUIRED BY A "U.L. NO." LISTING SHALL BE FOLLOWED WITHOUT DEVIATION, UNLESS OTHERWISE NOTED OR DETAILED.
37. CONTRACTOR TO FURNISH AND INSTALL ALL BLOCKING REQUIRED FOR WALL MOUNTED OR BRACED FIXTURES, MILLWORK, SHELVES, TOILET FIXTURES, AND ACCESSORIES OR 'BY OTHER' ITEMS DESCRIBED IN INTERIOR DESIGN AND ARCHITECTURAL
DRAWINGS. BLOCKING SHALL BE CONSTRUCTED TO SUPPORT THE IMPOSED LOAD.
38. ALL MANUFACTURED ARTICLES, MATERIALS AND EQUIPMENT SHALL BE SUPPLIED, INSTALLED, CONNECTED, ERECTED, USED, CLEANED AND CONDITIONED AS DIRECTED BY THE MANUFACTURERS AND REQUIRED BY CODE.
39. PRIOR TO CONSTRUCTION, CONTRACTOR TO VERIFY/COORDINATE UTILITY REQUIREMENTS FOR ALL OWNER/VENDOR FURNISHED EQUIPMENT, FIXTURES OR APPLIANCES.
40. CONTRACTOR SHALL PROVIDE ALL NECESSARY FASTENERS, SUPPORTS, SHIMMING, FLASH PATCHING, ETC. FOR THE PROPER INSTALLATION OF SUCH ITEMS AS DIRECTED BY THE MANUFACTURERS.
41. UPON COMPLETION OF THE PROJECT, THE CONTRACTOR SHALL GIVE TO THE OWNER A COMPLETE SET OF AS-BUILT CIVIL, LANDSCAPE, ARCHITECTURAL, MECHANICAL, PLUMBING, ELECTRICAL AND FIRE PROTECTION DRAWINGS ALONG WITH THE WRITTEN
GUARANTIES, OPERATION AND MAINTENANCE MANUALS OF ALL EQUIPMENT AND FINISHES INSTALLED. THE CONTRACTOR SHALL MAINTAIN A CURRENT SET OF AS-BUILT DRAWINGS AND SPECIFICATIONS. INFORMATION SHALL BE RECORDED BY CONTRACTOR
AS CONSTRUCTION PROGRESSES AND REVIEWED FOR COMPLETENESS AT EACH REQUISITION REQUEST.
42. CONTRACTOR IS RESPONSIBLE TO THOROUGHLY VACUUM CLEAN ALL CARPETED AREAS, CLEAN ALL FLOORING, MILLWORK, LIGHT FIXTURES, GLASS, ETC. AND UNCOVER AND VACUUM OUT ALL MECHANICAL UNITES AFTER THE WORK IS COMPLETED AND
MAINTAIN CLEAN CONDITIONS THROUGH THE TENANT'S MOVE-IN.
WATERPROOFING AND DAMPPROOFING NOTES:
R406.1 CONCRETE AND MASONRY FOUNDATION DAMPPROOFING
EXCEPT WHERE REQUIRED BY SECTION R406.2 TO BE WATERPROOFED, FOUNDATION WALLS THAT RETAIN EARTH AND
ENCLOSE INTERIOR SPACES AND FLOORS BELOW GRADE SHALL BE DAMPPROOFED FROM THE HIGHER OF (A) THE TOP OF THE
FOOTING OR (B) 6 INCHES (152 MM) BELOW THE TOP OF THE BASEMENT FLOOR, TO THE FINISHED GRADE. MASONRY WALLS
SHALL HAVE NOT LESS THAN 3/8-INCH (9.5 MM) PORTLAND CEMENT PARGING APPLIED TO THE EXTERIOR OF THE WALL. THE
PARGING SHALL BE DAMPPROOFED IN ACCORDANCE WITH ONE OF THE FOLLOWING:
1. BITUMINOUS COATING.
2. THREE POUNDS PER SQUARE YARD (1.63 KG/M2) OF ACRYLIC MODIFIED CEMENT.
3. ONE-EIGHTH-INCH (3.2 MM) COAT OF SURFACE-BONDING CEMENT COMPLYING WITH ASTM C887.
4. ANY MATERIAL PERMITTED FOR WATERPROOFING IN SECTION R406.2.
5. OTHER APPROVED METHODS OR MATERIALS.
EXCEPTION:PARGING OF UNIT MASONRY WALLS IS NOT REQUIRED WHERE A MATERIAL IS APPROVED FOR DIRECT
APPLICATION TO THE MASONRY.CONCRETE WALLS SHALL BE DAMPPROOFED BY APPLYING ANY ONE OF THE LISTED
DAMPPROOFING MATERIALS OR ANY ONE OF THE WATERPROOFING MATERIALS LISTED IN SECTION R406.2 TO THE EXTERIOR
OF THE WALL.
R406.2 CONCRETE AND MASONRY FOUNDATION WATERPROOFING
IN AREAS WHERE A HIGH WATER TABLE OR OTHER SEVERE SOIL-WATER CONDITIONS ARE KNOWN TO EXIST, EXTERIOR
FOUNDATION WALLS THAT RETAIN EARTH AND ENCLOSE INTERIOR SPACES AND FLOORS BELOW GRADE SHALL BE
WATERPROOFED FROM THE HIGHER OF (A) THE TOP OF THE FOOTING OR (B) 6 INCHES (152 MM) BELOW THE TOP OF THE
BASEMENT FLOOR, TO THE FINISHED GRADE. WALLS SHALL BE WATERPROOFED IN ACCORDANCE WITH ONE OF THE
FOLLOWING:
1. TWO-PLY HOT-MOPPED FELTS.
2. FIFTY-FIVE-POUND (25 KG) ROLL ROOFING.
3. SIX-MIL (0.15 MM) POLYVINYL CHLORIDE.
4. SIX-MIL (0.15 MM) POLYETHYLENE.
5. FORTY-MIL (1 MM) POLYMER-MODIFIED ASPHALT.
6. SIXTY-MIL (1.5 MM) FLEXIBLE POLYMER CEMENT.
7. ONE-EIGHTH-INCH (3 MM) CEMENT-BASED, FIBER-REINFORCED, WATERPROOF COATING.
8. SIXTY-MIL (1.5 MM) SOLVENT-FREE LIQUID-APPLIED SYNTHETIC RUBBER.
ALL JOINTS IN MEMBRANE WATERPROOFING SHALL BE LAPPED AND SEALED WITH AN ADHESIVE COMPATIBLE WITH THE
MEMBRANE.
EXCEPTION: ORGANIC-SOLVENT-BASED PRODUCTS SUCH AS HYDROCARBONS, CHLORINATED HYDROCARBONS, KETONES AND
ESTERS SHALL NOT BE USED FOR ICF WALLS WITH EXPANDED POLYSTYRENE FORM MATERIAL. USE OF PLASTIC ROOFING
CEMENTS, ACRYLIC COATINGS, LATEX COATINGS, MORTARS AND PARGINGS TO SEAL ICF WALLS IS PERMITTED. COLD-SETTING
ASPHALT OR HOT ASPHALT SHALL CONFORM TO TYPE C OF ASTM D449. HOT ASPHALT SHALL BE APPLIED AT A TEMPERATURE
OF LESS THAN 200°F (93°C).
DIMENSION NOTE:
ALL DIMENSIONS ARE TO FACE OF SHEATHING (EXT. WALLS) OR FACE OF STRUCTURE (F.O.S.) TYP. U.N.O. ROUNDED TO THE
NEAREST 1/8" AND INTERIOR PARTITIONS ARE DIMENSIONED FROM FACE OF STRUCTURE TO FACE OF STRUCTURE (F.O.S.)
U.N.O. -CONTACT ARCHITECT IN WRITING FOR ANY CLARIFICATION OF NOTED DIMENSIONS, DO NOT SCALE PLANS.
ROUGH FRAMING:
ALL EXTERIOR WALLS TO BE FRAMED W/. 2X6 STUD MIN. U.N.O.
USE 2X6 MINIMUM STUDS FOR PLUMBING WALLS
SECOND AND THIRD FLOOR PLYWOOD TO BE 1-1/8"
ENTIRE EXTERIOR TO BE SHEATHED WITH 1/2" PLYWOOD
DOORS AND WINDOWS WILL TYPICALLY BE RECESSED FROM EXTERIOR WALL PLANE. VERIFY ALL ROUGH OPENING
DIMENSIONS WITH DOOR AND WINDOW MFGR. ROUGH OPENING MAY NEED TO BE OVERSIZED TO ACCOUNT FOR ADDITIONAL
FRAMING. SEE SHT. AD-2.0 FOR TYP. RECESSED CONDITIONS.
DUCTS PENETRATION:
DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE
SHALL BE CONSTRUCTED OF A MINIMUM NO. 26 GAGE (0.48 MM) SHEET STEEL OR OTHER APPROVED MATERIAL AND SHALL
NOT HAVE OPENINGS INTO THE GARAGE (R302.5.2)
STAIRWAY ILLUMINATION:
1.INTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE TO ILLUMINATE THE LANDINGS AND TREADS.
THE LIGHT SOURCE SHALL BE CAPABLE OF ILLUMINATING TREADS AND LANDINGS TO LEVELS OF NOT LESS THAN 1 FOOT-
CANDLE (11 LUX) AS MEASURED AT THE CENTER OF TREADS AND LANDINGS. THERE SHALL BE A WALL SWITCH AT EACH
FLOOR LEVEL TO CONTROL THE LIGHT SOURCE WHERE THE STAIRWAY HAS SIX OR MORE RISERS. (R303.7)
EXCEPTION:A SWITCH IS NOT REQUIRED WHERE REMOTE, CENTRAL OR AUTOMATIC CONTROL OF LIGHTING IS
PROVIDED.
2.EXTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE LOCATED AT THE TOP LANDING OF THE
STAIRWAY. EXTERIOR STAIRWAYS PROVIDING ACCESS TO A BASEMENT FROM THE OUTDOOR GRADE LEVEL SHALL BE
PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE LOCATED AT THE BOTTOM LANDING OF THE STAIRWAY. (R303.8)
GARAGE FLOOR:
GARAGE FLOOR SURFACES SHALL BE OF APPROVED NONCOMBUSTIBLE MATERIAL.THE AREA OF FLOOR USED FOR PARKING OF
AUTOMOBILES OR OTHER VEHICLES SHALL BE SLOPED TO FACILITATE THE MOVEMENT OF LIQUIDS TO A DRAIN OR TOWARD
THE MAIN VEHICLE ENTRY DOORWAY. (R309.1)
PLUMBING:
1. ALL FIXTURES AND FITTINGS SHALL COMPLY WITH THE MAX FLOW RATE SET BY CALGREEN (CALIFORNIA GREEN BUILDING
STANDARD CODE) AND CALIFORNIA PLUMBING CODES. G.C. TO VERIFY PRIOR TO PURCHASE AND INSTALL OF ANY FIXTURE
AND FITTING
2. MAX. TEMP. OF 120° TO BE APPROVED BY THE USE OF PRESSURE BALANCE OR THERMOSTATIC MIXING VALVES TYP. IN
COMPLIANCE W/. ASSE 1070/ASME A112.1070/CSA B125.70 @ SHOWERS & TUBS.
3. MAX. TEMP. OF 110° TO BE APPROVED BY THE USE OF PRESSURE BALANCE OR THERMOSTATIC MIXING VALVES TYP. IN
COMPLIANCE W/. ASSE 1070/ASME A112.1070/CSA B125.70 @ BIDETS.
4. SUPPORT ALL WALL-HUNG FIXTURES WITH METAL SUPPORTING MEMBERS TO PREVENT ANY STRAIN TRANSMISSION TO
THE CONNECTIONS. FRAMING AFFIXED SUPPORTS FOR OFF-THE-FLOOR WATER CLOSETS WITH CONCEALED TANKS SHALL
COMPLY WITH ASME A112.6.2. SECURE FLUSH TANK AND SIMILAR APPURTENANCES WITH APPROVED NON-CORROSIVE SCREW
OR BOLTS. (CPC 402.5)
5. THE NET AREA OF THE SHOWER ENCLOSURE SHALL BE 1,024 SQ. INCHES (7.1 SQ. FT.) OR MORE IN THE CLEAR FLOOR AREA,
AND SHALL ALSO BE CAPABLE OF ENCOMPASSING A 30-INCH DIAMETER CIRCLE. (CPC 408.6)
6. THE WATER HEATER BURNER AND BURNER-IGNITION DEVICE TO BE AT LEAST 18-INCHES ABOVE THE FLOOR, IF LOCATED IN A
GARAGE AND IN ADJACENT SPACES THAT OPEN TO THE GARAGE. FOR WATER HEATER IN THE GARAGE OR OTHER AREAS
SUBJECT TO MECHANICAL DAMAGE PROVIDE A PROTECTIVE BARRIER OR ELEVATE THE APPLIANCE TO BE OUT OF THE NORMAL
PATH OF THE VEHICLE. (CPC 507.13)
7. ANCHOR OR STRAP THE WATER HEATER(S) TO RESIST HORIZ. DISPLACEMENT DUE TO THE EARTHQUAKE. STRAPPING
SHOULD BE AT THE UPPER AND LOWER ONE THIRD (1/3) POINTS OF THE APPLIANCE HEIGHT. MAINTAIN A MIN. 4-INCHES
ABOVE THE CONTROLS WITH STRAPPING AT LOWER POINT.
MATERIALS & FINISHES:
1. WALLS COVERINGS AND FLOOR OF SHOWERS AND BATHTUBS WITH A SHOWER HEAD SHALL BE OF CEMENT PLASTER, TILE,
OR APPROVED EQUAL NONABSORBENT SURFACE, TO A HEIGHT OF NOT LESS THAN 72-INCHES ABOVE THE FLOOR. PROVIDE
CEMENT BOARD, CEMENT PLASTER BACKING, OR TILE BACKBOARD FOR TILE FINISH. (CRC R307.2)
2. INSTALL MIN. 5/8" TYPE 'X' MOISTURE & MOLD RESISTANT GYPSUM WALL BOARD IN ALL BATHROOMS AND KITCHENS.
FIREPLACES:
1. FACTORY-BUILT FIREPLACES, CHIMNEYS AND ALL OF THEIR COMPONENTS SHALL BE LISTED AND INSTALLED IN
ACCORDANCE WITH THEIR LISTING AND MANUFACTURER'S INSTALLATION INSTRUCTIONS. (CRC R1004.1)
2. FACTORY BUILT WOOD BURNING FIREPLACES SHALL BE QUALIFIED AT THE U.S. EPA’S VOLUNTARY FIREPLACE PROGRAM
PHASE 2 EMISSIONS LEVEL. (CRC 1004.1.1)
3. DECORATIVE SHROUDS SHALL NOT BE INSTALLED AT THE TERMINATION OF FACTORY-BUILT CHIMNEYS EXCEPT WHERE
SUCH SHROUDS ARE LISTED AND LABELED FOR USE WITH THE SPECIFIC FACTORY-BUILT CHIMNEY SYSTEM AND ARE
INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS. (CRC R1005.2 & CMC 802.5.1.1 & CMC
802.5.4.3)
4. HORIZONTAL OPENINGS ARE NOT ALLOWED, FOR EXHAUST VENTS, IN WALLS CLOSER THAN 3 FEET TO A PROPERTY LINE.
(TABLES R302.1(1)&(2)). HORIZONTAL VENT CAPS SHALL BE 2 FEET CLEAR FROM PROPERTY LINES.
5. EXHAUST OPENINGS SHALL NOT BE DIRECTED ONTO WALKWAYS. (R303.5.2)
6. SOLID FUEL BURNING FIREPLACES (IF PERMISSIBLE):
A. PROVIDE A PERMANENTLY ANCHORED GASEOUS FUEL BURNING PAN TO THE FIREBOX OF A SOLID
FUEL BURNING FIREPLACE.
B. SOLID FUEL BURNING FIREPLACE MUST COMPLY WITH THE CALIFORNIA ENERGY STANDARDS MANDATORY MEASURES.
C. CHIMNEY SHALL EXTEND AT LEAST 2 FT. HIGHER THAN ANY PORTION OF THE BUILDING WITHIN 10 FT., BUT SHALL
NOT BE LESS THAN 3 FT. ABOVE THE HIGHEST POINT WHERE THE CHIMNEY PASSES THROUGH THE ROOF. (CRC R1003.9)
D. LIQUID FUELED FIREPLACES ARE NOT ALLOWED FOR INTERIOR USE.
7. ANY INSTALLED GAS FIREPLACE SHALL BE DIRECT VENT SEALED-COMBUSTION PER CAL GREEN SECTION 4.503.
POOL:
1. PROVIDE AN ALARM FOR DOORS AND WINDOWS WITH SILL HEIGHTS LESS THAN 60-INCHES ABV.F.F. OF THE DWELLING THAT
FORMS A PART OF THE POOL ENCLOSURE. THE ALARM SHALL BE LISTED AS A WATER HAZARD ENTRANCE ALARM IN
ACCORDANCE WITH UL 2017. THE DEACTIVATION SWITCH SHALL BE AT LEAST 60" ABOVE THE FLOOR IF THE RESIDENCE IS NOT
REQUIRED TO BE ACCESSIBLE. (CBC 3109 & ISPSC 305.4)
2. SUCTION OUTLETS SHALL BE DESIGNED AND INSTALLED WITH SUCTION ANTIENTRAPMENT GRATE IN ACCORDANCE WITH
ANSI/APSP-16 PER CBC 3109 SECTION (B) OF 115928. SUCTION ENTRAPMENT AVOIDANCE FOR POOL AND SPA SHALL BE
PROVIDED IN ACCORDANCE WITH APSP-7 PER ISPSC SECTION 310.
3. PROVIDE POWER SAFETY COVER IN COMPLIANCE WITH ASTM F1346-91 FOR POOL & SPA (CBC 3109 SECTION (3) OF 115922
& ISPSC 305).
4. POOL ENCLOSURE FENCE SHALL BE 60-INCHES MIN. ABV. FS/NG MEASURED ON THE SIDE THAT FACES AWAY FROM
SWIMMING POOL W/. MAX VERTICAL CLEARANCE OF 2-INCHES BETWEEN FS/NG AND BOTTOM OF THE FENCE/BARRIER
MEASURED ON THE SIDE OF FENCE THAT FACES AWAY FROM SWIMMING POOL. OPENING, GAP, AND VOID IN ENCLOSURE
FENCE OR GATE SHALL NOT ALLOW THE PASSAGE OF 4-INCHES DIAMETER SPHERE OR LARGER. OUTSIDE SURFACE (FACING
AWAY FROM SWIMMING POOL) OF THE POOL ENCLOSURE INCLUDING THE GATE TO BE FREE OF PROTRUSIONS, CAVITIES, OR
OTHER PHYSICAL CHARACTERISTICS THAT WOULD SERVE AS HANDHOLDS OR FOOTHOLDS WHICH COULD ENABLE A CHILD FIVE
YEARS OLD OR YOUNGER TO CLIMB OVER. (CBC 3109 & ISPSC 305)
WOOD OR WOODBASED PRODUCTS NOTE:
WOOD OR WOODBASE PRODUCT SHALL BE OF A NATURAL DURABLE OR PRESERVATIVE-TREADED WOOD IN ACCORDANCE WITH
AWPA U1 FOR THE SPECIES, PRODUCT, PRESERVATIVE AND END USE IN THE FOLLOWING LOCATIONS:
1. WOOD JOISTS OR THE BOTTOM OF A WOOD STRUCTURAL FLOOR WHEN CLOSER THAN 18 INCHES (457 MM) OR WOOD
GIRDERS WHEN CLOSER THAN 12 INCHES (305 MM) TO THE EXPOSED GROUND IN CRAWL SPACES OR UNEXCAVATED AREA
LOCATED WITHIN THE PERIPHERY OF THE BUILDING FOUNDATION.
2. WOOD FRAMING MEMBERS THAT REST ON CONCRETE OR MASONRY EXTERIOR FOUNDATION WALLS AND ARE LESS THAN 8
INCHES (203 MM) FROM THE EXPOSED GROUND.
3. SILLS AND SLEEPERS ON A CONCRETE OR MASONRY SLAB THAT IS IN DIRECT CONTACT WITH THE GROUND UNLESS
SEPARATED FROM SUCH SLAB BY AN IMPERVIOUS MOISTURE BARRIER.
4. THE ENDS OF WOOD GIRDERS ENTERING EXTERIOR MASONRY OR CONCRETE WALLS HAVING CLEARANCES OF LESS THAN
1/2 INCH (12.7 MM) ON TOPS, SIDES AND ENDS.
5. WOOD SIDING, SHEATHING AND WALL FRAMING ON THE EXTERIOR OF A BUILDING HAVING A CLEARANCE OF LESS THAN 6
INCHES (152 MM) FROM THE GROUND OR LESS THAN 2 INCHES (51 MM) MEASURED VERTICALLY FROM CONCRETE STEPS,
PORCH SLABS, PATIO SLABS AND SIMILAR HORIZONTAL SURFACES EXPOSED TO THE WEATHER.
6. WOOD STRUCTURAL MEMBERS SUPPORTING MOISTURE-PERMEABLE FLOORS OR ROOFS THAT ARE EXPOSED TO THE
WEATHER, SUCH AS CONCRETE OR MASONRY SLABS, UNLESS SEPARATED FROM SUCH FLOORS OR ROOFS BY AN IMPERVIOUS
MOISTURE BARRIER.
7. WOOD FURRING STRIPS OR OTHER WOOD FRAMING MEMBERS ATTACHED DIRECTLY TO THE INTERIOR OF EXTERIOR
MASONRY WALLS OR CONCRETE WALLS BELOW GRADE EXCEPT WHERE AN APPROVED VAPOR RETARDER IS APPLIED BETWEEN
THE WALL AND THE FURRING STRIPS OR FRAMING MEMBERS.
WASHER & DRYER NOTE:
AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –PROVIDE POWER , GAS, WATER SUPPLY & DRAINAGE AS REQUIRED -THE
CLOTHES DRYERS VENT SHALL BE OF A RIGID METALLIC MATERIAL AND HAVE A BACKDRAFT DAMPER (CMC 504.4) AND SHALL
NOT EXCEED 14-FEET IN OVERALL LENGTH WITH MAX. OF TWO (2) 90-DEGREE ELBOW, SUBTRACT 2-FEET FOR EACH
ADDITIONAL 90-DEGREE ELBOW. (CMC 504.4.2.1) DRYER VENT TERMINATION MUST BE 3-FEET FROM OPENINGS INTO THE
BUILDING (DOORS AND OPERABLE WINDOWS), 10-FEET FROM FORCED AIR INLET, AND 3-FEET FROM PROPERTY LINE (NOT TO
DISCHARGE ONTO A PUBLIC WALKWAY). (CMC 502.2.1) IF DRYER LOCATED IN A CLOSET PROVIDE A MIN. 100 SQ.IN. OPENING
IN THE CLOSET DOOR. (CMC. 504.4.1)
*HERS VERIFICATION REQUIRED-REFERENCE T-24.1
&AND
.ANGLE
@ AT
C.L. CENTERLINE
∅DIAMETER, ROUND
.PERPENDICULAR
# POUND OR NUMBER
A.B.ANCHOR BOLT
ABV. ABOVE
A/C.AIR CONDITIONING
A.C.ASPHALT CONCRETE
ACOUS ACOUSTICAL
A.D.AREA DRAIN
ADH. ADHESIVE
ADJ. ADJUSTABLE, ADJACENT
AL.ALUMINUM
ALT.ALTERNATE
ANOD.ANODIZED
A.P.ACCESS PANEL
APPX. APPROXIMATE
APPV'D. APPROVED
ARCH.ARCHITECTURAL,ARCHITECT
ASB. ASBESTOS
ASSY. ASSEMBLY
AUTO.AUTOMATIC
B. BATHROOM
BD. BOARD
BEL. BELOW
BET. BETWEEN
BIT. BITUMINOUS
BLDG.BUILDING
BLK. BLOCK
BLK'G.BLOCKING
BM. BEAM
B.O.BY OWNER, BY OTHERS
BOT. BOTTOM
BR. BEDROOM
B.W. BACK OF WALL, BOTTOM OF WALL
CAB. CABINET
C.B.CATCH BASIN
C.B.C. CALIFORNIA BUILDING CODE
C.R.C. CALIFORNIA RESIDENTIAL CODE
CEM.CEMENT
C.G.CORNER GUARD
CHAN.CHANNEL
CHG.CHANGE
C.I. CAST IRON
C.J. CONTROL / CONSTRUCT./CEILING JOINT
CLG. CEILING
CLKG. CAULKING
CLR. CLEAR, CLEARANCE
CNTR.COUNTER
CONC.CONCRETE
COND.CONDITION
CONST. CONSTRUCT, CONSTRUCTION
CORR.CORRIDOR, CORROSIVE
CTSK. COUNTER SINK, COUNTERSUNK
CTR. CENTER
DBL. DOUBLE
DECO.DECORATIVE
DEPT. DEPARTMENT
DET. DETAIL
D.F.DRINKING FOUNTAIN, DOUGLAS FIR
DIA.DIAMETER
DIAG. DIAGONAL
DIM. DIMENSION
DN. DOWN
DR. DOOR
D.S.DOWNSPOUT
D.S.P. DRY STANDPIPE
DWG. DRAWING(S)
E. EXISTING, EAST, ENTRY, EACH
E.J. EXPANSION JOINT
ELEC. ELECTRIC, ELECTRICAL
ELEV. ELEVATOR
EMER.EMERGENCY
ENCL. ENCLOSED, ENCLOSURE
E.P.ELECTRICAL PANEL, END POINT
EQ. EQUAL
EQV. EQUIVALENT
EQUIP.EQUIPMENT
E.W. EACH WAY
EXH. EXHAUST
EXPO.EXPOSED
EXT. EXTERIOR
E.G.EXISTING GRADE
F.FIXED
F.A. FIRE ALARM
FAC. FACTORY
F.C.O. FLOOR CLEAN OUT
F.D.FLOOR DRAIN
FDN. FOUNDATION
F.E. FIRE EXTINGUISHER
F.E.C. FIRE EXTINGUISHER CABINET
F.G.FINISH GRADE
FIXT.FIXTURE
F.J. FLOOR JOIST
F.L. FLOW LINE
FLASH. FLASHING
FLR. FLOOR
FLUOR. FLUORESCENT
F.O.C. FACE OF CONCRETE/CURB
F.O.F. FACE OF FINISH
F.O.S. FACE OF STUD / STRUCTURE / SHEATHING
F.O.M.FACE OF MASONRY
FP. FIREPLACE
F.S. FLOOR SINK, FINISH SURFACE
FT.FOOT, FEET
FTG. FOOTING
FURR.FURRING
FUT. FUTURE
F.V. FIELD VERIFY
GA. GAUGE
GALV. GALVANIZED
G.B.GRAB BAR, GRADE BEAM
G.C.GENERAL CONTRACTOR
GEN.GENERAL
G.F.I.GROUND FAULT INTERRUPT
G.I. GALVANIZED IRON
G.L.B. GLU-LAM BEAM
GND.GROUND
GR. GRADE
GYP. GYPSUM
G.P.GRADE PLANE
H./HT. HIGH, HEIGHT
H.B.HOSE BIBB
H.C.HOLLOW CORE
HD. HARD, HEAD
HDR.HEADER
HDWD.HARDWOOD
HDWR.HARDWARE
H.M. HOLLOW METAL
HORIZ. HORIZONTAL
HR. HOUR
HVAC HEATING VENTILATING AIR CONDITIONING
I.D. INTERIOR DESIGNER, INSIDE DIAMETER/DIMENSION
IN.INCH
INSUL.INSULATION
INT.INTERIOR
INV.INVERT/INVERTED
JAN. JANITOR
JT.JOINT
JST.JOIST
KIT. KITCHEN
L.LOW, LINEN
L.A. LANDSCAPED AREA
LAB. LABORATORY
LAM. LAMINATED
LAV. LAVATORY
LBS. POUNDS
LFA.LOAD FROM ABOVE
L.H. LEFT HAND
LKR. LOCKER
LT.LIGHT
LUM. LUMINOUS, LUMENS
MAINT. MAINTENANCE
MAS.MASONRY
MAT. MATERIAL
MAX.MAXIMUM
M.B.METAL BOLT
M.C. MEDICINE CABINET
MECH.MECHANICAL
MEMB.MEMBRANE
MTL. METAL
MFGR.MANUFACTURER
M.H. MANHOLE
MIN. MINIMUM
MIR. MIRROR
MISC. MISCELLANEOUS
M.O. MASONRY OPENING
MT. MOUNTED
MUL. MULLION
N. NEW, NORTH
NAT. NATURAL
N.I.C.NOT IN CONTRACT, CONTACT
N.G.NATURAL GRADE
NO. NUMBER
NOM.NOMINAL
N.T.S. NOT TO SCALE
O/.OVER
O.A.OVERALL
OBS. OBSCURE
O.C.ON CENTER
O.D.OUTSIDE DIAMETER, DIMENSION
O.F.D. OVERFLOW DRAIN
OFF. OFFICE
OPNG.OPENING
OPP. OPPOSITE
PERIM. PERIMETER
PL.PROPERTY LINE, PLATE
P.LAM. PLASTIC LAMINATE
PLAS. PLASTER
PLUMB. PLUMBING
PLYWD. PLYWOOD
PNT. PAINT(ED)
P.O.C. POINT OF CONTACT, CONNECTION
PR. PAIR
PROJ. PROJECTION
PSL. PARALLEL STRAND LAMINATE
PT. POINT
R.A.RETURN AIR
RAD. RADIUS
R.D.ROOF DRAIN
R.D.L. ROOF DRAIN LEADER
RECPT. RECEPTACLE
RECT. RECTANGLE, RECTANGULAR
REF. REFERENCE
REFR.REFRIGERATOR
REG.REGULAR, REGISTER
REINF. REINFORCE(D), REINFORCEMENT
REQ'D. REQUIRED
RESIL.RESILIENT
RET. RETAIN(ING), RETURN
RM. ROOM
R.O.ROUGH OPENING
R.R.ROOF RAFTER
RWD. REDWOOD
S. SOUTH
S.A.SUPPLY AIR
S.C.SOLID CORE
S.C.D. SEAT COVER DISPENSER
SCHED. SCHEDULE
S.D.SUBDRAIN, SOAP DISPENSER
SEC. SECTION
SEL. SELECT(ED)
SH. SHELF
SHT. SHEET
SHT'G.SHEATHING
SIM.SIMILAR
SIMP. SIMPSON
S.J. SOFFIT JOIST
S.S.STAINLESS STEEL
S.SK.SERVICE SINK
STA. STATION
STD. STANDARD
STL.STEEL
STOR.STORAGE
STRUCT. STRUCTURE, STRUCTURAL
SUSP. SUSPEND(ED)
SYM.SYMMETRICAL
SYS. SYSTEM
T.TREAD, TRASH
T.C.TOP OF CURB
T.CL. TIME CLOCK
TEL.TELEPHONE
TEMP.TEMPERED
TER. TERRAZZO
T & G TONGUE & GROOVE
THK. THICK, THICKNESS
T.P. TOP OF PAVING
T.PL. TOP OF PLATE
T.O.S. TOP OF STRUCTURE, SHEATHING, SLAB
TRANS. TRANSFORMER
T.S. TOP OF STEP
T.W.TOP OF WALL
TYP. TYPICAL
U. UNDER
U.B.C. UNIFORMBUILDING CODE
U.G.UNDERGROUND
U.L. UNDERWRITER'S LABORATORY
UNF. UNFINISHED
U.N.O.UNLESS NOTED OTHERWISE
UR. URINAL
V./VERT. VERTICAL
VENT. VENTILATION, VENTILATING
VER. VERIFY
V.T.R. VENT THROUGH ROOF
W. WEST, WIDTH, WASHER
W/.WITH
WD.WOOD
W.H. WATER HEATER
W.C.WATER CLOSET
W.I. WROUGHT IRON
WP.WATERPROOF(ING)
W.W.M. WELDED WIRE MESH
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
BRANDON ARCHITECTS
CONTRACT DOCUMENT NOTESAGENERAL NOTESBABBREVIATIONSC
2/16/2022
ARCHITECTURAL
GENERAL NOTESHEDGE RESIDENCEEDDIE AND DESIREE HEDGE
1400 W. BAY AVENUE
NEWPORT BEACH, CA 92661
DD
1400 W. BAY AVENUE
T-1.1
**0000-2021**
JEFF VAN VOORHIS
NO. REVISION DATE
PA2022-0187
PA2022-0187
PRECISE GRADING PLAN
FOR HEDGE RESIDENCE
1400 W BAY AVENUE
NEWPORT BEACH, CA 92661JOB NO.DATESHEET NO.REVISIONS22039NO. REVISION DATESHEET NO. OF 48/18/202228052 CAMINO CAPISTRANO, STE 213
LAGUNA NIGUEL, CA 92677
949.464.8115 info@civilscapes.com
G:\Projects\22039 1400 W Bay Ave, NB\DWG\22039.GRADING.dwg1C1 TITLE SHEET 1.ALL WORK SHALL CONFORM TO CHAPTER 15 OF THE NEWPORT BEACH MUNICIPAL CODE(NBMC), THE PROJECT SOILS REPORT AND SPECIAL REQUIREMENTS OF THE PERMIT.2. DUST SHALL BE CONTROLLED BY WATERING AND/OF JUST PALLIATIVE.3. SANITARY FACILITIES SHALL BE MAINTAINED ON THE SITE DURING CONSTRUCTION PERIOD.4. WORK HOURS ARE LIMITED FROM 7:00 AM TO 6:30 PM MONDAY THROUGH FRIDAY; 8:00AM TO 6:00 PM SATURDAYS; AND NO WORK ON SUNDAYS AND HOLIDAYS PER SECTION10-28 OF THE NBMC.5. NOISE, EXCAVATION, DELIVERY AND REMOVAL SHALL BE CONTROLLED PER SECTION 10-28OF THE NBMC.6. THE STAMPED SET OF THE APPROVED PLANS SHALL BE ON THE JOB SITE AT ALL TIMES.7. PERMITTEE AND CONTRACTOR ARE RESPONSIBLE FOR LOCATING AND PROTECTINGUTILITIES.8. APPROVED SHORING, DRAINAGE PROVISION AND PROTECTIVE MEASURES MUST BE USEDTO PROTECT ADJOINING PROPERTIES DURING THE GRADING OPERATION.9. CESSPOOLS AND SEPTIC TANKS SHALL BE ABANDONED IN COMPLIANCE WITH THEUNIFORM PLUMBING CODE AND APPROVED BY THE BUILDING OFFICIAL.10. HAUL ROUTES FOR IMPORT OR EXPORT OF MATERIALS SHALL BE APPROVED BY THE CITYTRAFFIC ENGINEER AND PROCEDURES SHALL CONFORM WITH CHAPTER 15 OF THE NBMC.11. POSITIVE DRAINAGE SHALL BE MAINTAINED AWAY FROM ALL BUILDINGS AND SLOPEAREAS.12. FAILURE TO REQUEST INSPECTIONS AND/OR HAVE REMOVABLE EROSION CONTROLDEVICES ON-SITE AT THE APPROPRIATE TIMES SHALL RESULT IN A "STOP WORK" ORDER.13. ALL PLASTIC DRAINAGE PIPES SHALL CONSIST OF PVC (SDR 35) WITH GLUED JOINTS.14. NO PAINT, PLASTER, CEMENT, SOIL, MORTAR OR OTHER RESIDUE, SHALL BE ALLOWED TOENTER STREETS CURBS, GUTTERS OR STORM DRAINS. ALL MATERIALS AND WASTES SHALLBE REMOVED FROM THE SITE.GENERAL NOTESCITY OF NEWPORT BEACH, CALIFORNIACOUNTY OF ORANGEC1 TITLE SHEETC2 GRADING PLANC3 EROSION CONTROL PLANC4 GEOTECHNICAL NOTESSHEET INDEX1400 W BAY AVENUENEWPORT BEACH, CA 92661APN: 047-221-11PRECISE GRADING PLANWILL ROLPHCIVILSCAPES ENGINEERING, INC.28052 CAMINO CAPISTRANO, STE 213LAGUNA NIGUEL, CA949.464.8115WILL@CIVILSCAPES.COMCIVIL ENGINEER1. CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLYACCEPTED CONSTRUCTION PRACTICES, CONSTRUCTION CONTRACTOR WILL BEREQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONSDURING THE COURSE OF CONSTRUCTION OF THE PROJECT, INCLUDING SAFETY OF ALLPERSONS AND PROPERTY; THAT IS REQUIREMENT SHALL BE MADE TO APPLYCONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS.2. NO UTILITY SEARCH WAS CONDUCTED. A UTILITY SEARCH BY THE CONTRACTOR SHALLBE CONDUCTED AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO TAKE DUEPRECAUTIONARY MEASURES TO PROTECT THE UTILITIES OR STRUCTURES FOUND ON THESITE AND TO NOTIFY THE OWNERS OF THE UTILITIES IMMEDIATELY UPON THEIRDISCOVERY.3. EARTHWORK AND OTHER CONSTRUCTION ITEM QUANTITIES SHOWN ON THESE PLANSARE ESTIMATES FOR PERMITTING PURPOSES ONLY AND SHALL NOT USED FORCONSTRUCTION COST ESTIMATES OR FOR BIDDING PURPOSES. THE CONTRACTOR SHALLDEVELOP OWN QUANTITIES FOR BIDDING PURPOSES.4. A SOILS INVESTIGATION MUST BE MADE BY A QUALIFIED SOILS ENGINEER AND/ORGEOLOGIST. SOIL AND EARTH ACCEPTABILITY ARE NOT UNDER PURVIEW OR THERESPONSIBILITY OF THE DESIGN ENGINEER FOR THIS PLAN. CIVILSCAPES ENGINEERINGDOES NOT TEST OR OBSERVE SOIL CONDITIONS PRIOR TO, DURING OR AFTERCONSTRUCTION AND HAS NO RESPONSIBILITY FOR SOILS (EARTH) STRUCTURES.5. ALL RETAINING WALL DESIGNS ARE TO BE BUILT PER STRUCTURAL ENGINEER'S PLAN ANDPER SEPARATE PLAN AND PERMIT.6. REFER TO SOILS REPORT FOR GRADING RECOMMENDATIONS.7. CONTRACTOR SHALL VERIFY EXISTING ELEVATION, PROTECT ALL EXISTING UTILITIES, ANDDOWNSTREAM DRAIN.8. TOPOGRAPHIC SURVEY SHOWN HEREON FOR REFERENCE PURPOSES ONLY.9. TOPOGRAPHIC SURVEY PREPARED BY: APEX LAND SURVEYING, INC., 8512 OXLEY CIRCLE,HUNTINGTON BEACH, CA. PHONE: 714-488-5006.10. VERIFY EXISTING TOPOGRAPHIC ELEVATIONS AND NOTIFY CIVILSCAPES ENGINEERING OFANY CONFLICTS PRIOR TO CONSTRUCTION.11. NO UTILITY SEARCH WAS CONDUCTED. CONTRACTOR SHALL PROTECT UTILITIES ORSTRUCTURES FOUND ON THE SITE AND NOTIFY CIVILSCAPES ENGINEERING OF ANYCONFLICTS.12. EXTERIOR FOUNDATIONS WALLS SHALL COMPLY WITH THE DETAILS AS SHOWN BELOW:13. PAD ELEVATION IS ASSUMED TO BE BASED ON ARCHITECTURAL FLOOR PLAN WITH ATLEAST 5" THICK CONCRETE AND 4" THICK BASE WITH VAPOR BARRIER PER SOILS REPORT.CONTRACTOR TO VERIFY WITH LATEST APPROVED SOILS REPORT AND STRUCTURALENGINEER FOR EXACT SLAB RECOMMENDATIONS.14. A PUBLIC WORKS DEPARTMENT ENCROACHMENT PERMIT INSPECTION IS REQUIREDBEFORE THE BUILDING DEPARTMENT PERMIT FINAL CAN BE ISSUED. AT THE TIME OFPUBLIC WORKS DEPARTMENT INSPECTION, IF AN OF THE EXISTING PUBLICIMPROVEMENTS SURROUNDING THE SITE IS DAMAGED, NEW CONCRETE SIDEWALK, CURBAND GUTTER, AND ALLEY/STREET PAVEMENT WILL BE REQUIRED AND 100% PAID BY THEOWNER. SAID DETERMINATION AND THE EXTENT OF THE REPAIR WORK SHALL BE MADEAT THE DISCRETION OF THE PUBLIC WORKS INSPECTOR.15. AN APPROVED ENCROACHMENT PERMIT IS REQUIRED FOR ALL WORK ACTIVITIES WITHINTHE PUBLIC RIGHT OF WAY. AN ENCROACHMENT AGREEMENT IS REQUIRED FOR ALLNON-STANDARD IMPROVEMENTS WITHIN THE PUBLIC RIGHT-OF-WAY.16. ALL WORK RELATED TO WATER IN THE PUBLIC RIGHT-OF-WAY SHALL BE PERFORMED BYA C-34 LICENSED PIPELINE CONTRACTOR OR AN A LICENSED GENERAL ENGINEERINGCONTRACTOR.17. ALL WORK RELATED TO WASTEWATER IN THE PUBLIC RIGHT-OF-WAY SHALL BEPERFORMED BY A C-42 LICENSED SANITATION SEWER CONTRACTOR OR AN A LICENSEDGENERAL ENGINEERING CONTRACTOR.18. EXISTING STREET TREE(S) SHALL BE PROTECTED IN PLACE.19. REMOVE EXISTING NON-GRASS PARKWAY ELEMENTS BETWEEN SIDEWALK AND CURB.REPLACE WITH SOD TO MATCH EXISTING AS REQUIRED.20. REFER TO SOILS REPORT FOR GRADING RECOMMENDATIONS AND OVER-EXCAVATIONREMOVALS AND COMPACTION REQUIREMENTS.21. PIPE MATERIAL MAY BE SUBSTITUTED IF APPROVED BY ENGINEER.22. INCLUDE ALL REQUIRED JOINTS AND FITTINGS. PER MANUFACTURER'S INSTALLATIONINSTRUCTIONS.23. UTILITIES SHALL BE CONSTRUCTED AND INSTALLED PER CALIFORNIA PLUMBING CODEAND CITY PLUMBING CODE. SERVICE LINES AND METER SIZES SHALL BE CONFIRMED BYPLUMBING ENGINEER OR CONTRACTOR PRIOR TO CONSTRUCTION.24. CONSTRUCT TRENCH, BEDDING, AND BACKFILL PER MANUFACTURER'S INSTALLATIONINSTRUCTIONS, ASTM D 2321, AND SOILS REPORT. 25. ALL FIXTURES, EQUIPMENT, PIPING AND MATERIALS SHALL BE LISTED.26. CONTRACTOR SHALL VERIFY ELEVATION PRIOR TO CONSTRUCTION AND NOTIFYENGINEER OF ANY DISCREPANCIES.27. ALL PRIVATE IRRIGATION SPRINKLER HEADS SHALL BE INSTALLED AND POSITIONED IN AMANNER THAT WILL NOT CAUSE IRRIGATION OVERSPRAY ONTO THE PUBLICRIGHT-OF-WAY.NOTES TO OWNER, CONTRACTOR, & ARCHITECTEDDIE AND DESIREE HEDGE1400 W BAY AVE.NEWPORT BEACH, CA 92661OWNEREARTHWORK QUANTITIES1. GRADED SLOPES SHALL BE NO STEEPER THAN 2 HORIZONTAL TO 1 VERTICAL.2. FILL SLOPES SHALL BE COMPACTED TO NO LESS THAN 90 PERCENT RELATIVECOMPACTION OUT TO THE FINISHED SURFACE.3. ALL FILLS SHALL BE COMPACTED THROUGHOUT TO THE MINIMUM OF 90 PERCENTRELATIVE COMPACTION AS DETERMINED BY ASTM TEST METHOD 1557, AND APPROVEDBY THE SOILS ENGINEER. COMPACTION TEST SHALL BE PERFORMED APPROXIMATELYEVERY TWO FEET IN VERTICAL HEIGHT AND OF SUFFICIENT QUANTITY TO ATTEST TO THEOVERALL COMPACTION EFFORT APPLIED TO THE FILL AREAS.4. AREAS TO RECEIVE FILL SHALL BE CLEARED OF ALL VEGETATION AND DEBRIS, SCARIFIEDAND APPROVED BY THE SOILS ENGINEER PRIOR TO PLACING OF THE FILL.5. FILLS SHALL BE KEYED OR BENCHED INTO COMPETENT MATERIAL.6. ALL EXISTING FILLS SHALL BE APPROVED BY THE SOILS ENGINEER OR REMOVED BEFOREANY ADDITIONAL FILLS ARE ADDED.7. ANY EXISTING IRRIGATION LINES AND CISTERNS SHALL BE REMOVED OR CRUSHED INPLACE AND BACKFILLED AND APPROVED BY THE SOILS ENGINEER.8. THE EXACT LOCATION OF THE SUBDRAINS SHALL BE SURVEYED IN THE FIELD FOR LINEAND GRADE.9. ALL TRENCH BACKFILLS SHALL BE COMPACTED THROUGHOUT THE MINIMUM OF 90PERCENT RELATIVE COMPACTION, AND APPROVED BY THE SOILS ENGINEER. THEBUILDING DEPARTMENT MAY REQUIRE CORING OF CONCRETE FLATWORK PLACED OVERUNTESTED BACKFILLS TO FACILITATE TESTING.10. THE STOCKPILING OF EXCESS MATERIAL SHALL BE APPROVED BY THE BUILDINGDEPARTMENT.11. ALL CUT SLOPES SHALL BE INVESTIGATED BOTH DURING AND AFTER GRADING BY ANENGINEERING GEOLOGIST TO DETERMINE IF ANY STABILITY PROBLEM EXISTS. SHOULDEXCAVATION DISCLOSE ANY GEOLOGICAL HAZARDS OR POTENTIAL GEOLOGICALHAZARDS, THE ENGINEERING GEOLOGISTS SHALL RECOMMEND AND SUBMIT NECESSARYTREATMENT TO THE BUILDING DEPARTMENT FOR APPROVAL.12. WHERE SUPPORT OR BUTTRESSING OF CUT AND NATURAL SLOPE IS DETERMINED TO BENECESSARY BY THE ENGINEERING GEOLOGIST AND SOILS ENGINEER, THE SOILSENGINEER WILL OBTAIN APPROVAL OF DESIGN, LOCATIONS AND CALCULATIONS FROMTHE BUILDING DEPARTMENT PRIOR TO CONSTRUCTION.13. THE ENGINEERING GEOLOGIST AND SOILS ENGINEER SHALL INSPECT AND TEST THECONSTRUCTION OF ALL BUTTRESS FILLS AND ATTEST TO THE STABILITY OF THE SLOPEAND ADJACENT STRUCTURES UPON COMPLETION.14. THE ENGINEERING GEOLOGIST SHALL PERFORM PERIODIC INSPECTIONS DURINGGRADING.15. NOTIFICATION OF NONCOMPLIANCE: IF IN THE COURSE OF FULFILLING THEIRRESPONSIBILITY, THE CIVIL ENGINEER, THE SOILS ENGINEER, THE ENGINEERINGGEOLOGIST OR THE TESTING AGENCY FINDS THAT THE WORK IS NOT BEING DONE INCONFORMANCE WITH THE APPROVED GRADING PLANS, THE DISCREPANCIES SHALL BEREPORTED IMMEDIATELY IN WRITING TO THE PERSON IN CHARGE OF THE GRADINGWORK AND TO THE BUILDING INSPECTOR. RECOMMENDATIONS FOR CORRECTIVEMEASURES, IF NECESSARY, SHALL BE SUBMITTED TO THE BUILDING DEPARTMENT FORAPPROVAL.GRADING NOTES1. ALL LOOSE SOIL AND DEBRIS SHALL BE REMOVED FROM PAVED SURFACES. AREAS UPONSTARTING OPERATIONS, AND PERIODICALLY THEREAFTER.2. SEDIMENT CONTROL MEASURES (I.E. GRAVEL BAGS OR EQUIVALENT) SHALL BEIMPLEMENTED AT THE PERIMETER OF ALL DISTURBED SOIL AREAS TO CONTROL RUN-ONAND RUN-OFF.3. GRAVEL BAGS AND NECESSARY MATERIALS SHALL BE AVAILABLE ON SITE AND STOCKPILEDAT CONVENIENT LOCATIONS TO FACILITATE RAPID CONSTRUCTION OF TEMPORARYDEVICES OR TO REPAIR ANY DAMAGED EROSION CONTROL MEASURES, WHEN RAIN ISIMMINENT. A STAND-BY CREW SHALL BE MADE AVAILABLE AT ALL TIMES DURING THERAINY SEASON.4. MATERIALS AND WASTE WITH THE POTENTIAL TO POLLUTE URBAN RUN-OFF SHALL BEUSED IN ACCORDANCE WITH LABEL DIRECTIONS AND SHALL BE STORED IN A MANNERTHAT EITHER PREVENTS CONTACT WITH RAINFALL OR CONTAINS CONTAMINATEDRUN-OFF FOR TREATMENT AND DISPOSAL.EROSION CONTROL NOTESSITE ADDRESS: 1400 W BAY AVE., NEWPORT BEACHAPN 047-221-11GENERAL PLAN LAND USE: RS-D SINGLE UNIT RESIDENTIAL DETACHEDZONING DISTRICT: R-1 SINGLE-UNIT RESIDENTIALCOSTAL ZONE: YESSITE DATA:ISSUANCE OF A BUILDING PERMIT BY THE CITY OF NEWPORT BEACH DOES NOT RELIEVEAPPLICANTS OF THE LEGAL REQUIREMENTS TO OBSERVE COVENANTS, CONDITIONS ANDRESTRICTIONS WHICH MAY BE RECORDED AGAINST THE PROPERTY OR TO OBTAINPLANS. YOU SHOULD CONTACT YOUR COMMUNITY ASSOCIATIONS PRIOR TOCOMMENCEMENT OF ANY CONSTRUCTION AUTHORIZED BY THIS PERMIT.CC&R'S1. PRIOR TO PERFORMING ANY WORK IN THE CITY RIGHT-OF-WAY ANENCROACHMENT PERMIT MUST BE OBTAINED FROM THE PUBLIC WORKSDEPARTMENT.2. A PUBLIC WORKS DEPARTMENT ENCROACHMENT PERMIT INSPECTION IS REQUIREDBEFORE THE BUILDING DEPARTMENT PERMIT FINAL CAN BE ISSUED. AT THE TIME OFPUBLIC WORKS DEPARTMENT INSPECTION, IF ANY OF THE EXISTING PUBLICIMPROVEMENTS SURROUNDING THE SITE IS DAMAGED, NEW CONCRETE SIDEWALK,CURB AND GUTTER, AND ALLEY/STREET PAVEMENT WILL BE REQUIRED.ADDITIONALLY, IF EXISTING UTILITIES INFRASTRUCTURE ARE DEEMED SUBSTANDARD,A NEW 1-INCH WATER SERVICE, WATER METER BOX, SEWER LATERAL AND/ORCLEANOUT WITH BOX AND LID WILL BE REQUIRED. 100% OF THE COST SHALL BEBORNE BY THE PROPERTY OWNER (MUNICIPAL CODES 14.24.020 AND 14.08.030).SAID DETERMINATION AND THE EXTENT OF THE REPAIR WORK SHALL BE MADE ATTHE DISCRETION OF THE PUBLIC WORKS INSPECTOR. CONTRACTOR IS RESPONSIBLETO MAINTAIN THE PUBLIC RIGHT OF WAY AT ALL TIMES DURING THECONSTRUCTION PROJECT. A STOP WORK NOTICE MAY BE ISSUED FOR ANY DAMAGEOR UNMAINTAINED PORTION OF THE PUBLIC RIGHT OF WAY.3. AN ENCROACHMENT AGREEMENT IS REQUIRED FOR ALL NON-STANDARDIMPROVEMENTS WITHIN THE PUBLIC RIGHT OF WAY. ALL NON-STANDARDIMPROVEMENTS SHALL COMPLY WITH CITY COUNCIL POLICY L-6.4. CONTRACTOR REMOVE ALL EXISTING DECORATIVE MATERIAL WITHIN THE PUBLICRIGHT-OF-WAY.5. ALL LANDSCAPING WITHIN THE PUBLIC RIGHT-OF-WAY SHALL HAVE A MAXIMUMGROWTH CHARACTERISTIC OF 36-INCHES.6. ALL PRIVATE IRRIGATION SPRINKLER HEADS SHALL BE INSTALLED AND POSITIONEDIN A MONNER THAT WILL NOT CAUSE IRRIGATION OVERSPRAY ONTO THE PUBLICRIGHT-OF-WAY.PUBLIC WORKS NOTESARCHITECTBRANDON ARCHITECTS151 KALMUS DRIVE, SUITE G-1COSTA MESA, CA 92626714.754.4040THIS GRADING PLAN HAS BEEN REVIEWED BY THE UNDERSIGNED AND FOUND TO BE INCONFORMANCE WITH THE RECOMMENDATIONS AS OUTLINED IN THE FOLLOWING SOILSREPORT FOR THIS PROJECTENTITLED: GEOTECHNICAL INVESTIGATIONPROJECT No.: BA364.1DATED: APRIL 11, 2022FIRM NAME: EGA CONSULTANTS, INC.GEOTECHNICAL CERTIFICATIONREFER TO GEOTECHNICAL INVESTIGATION FOR ADDITIONAL INFORMATION:EGA CONSULTANTS, INC.375-C MONTE VISTA AVENUECOSTA MESA, CA 92627949.642.9309SOILS ENGINEERNOTE:SURVEYOR OR ENGINEER SHALL PERMANENTLYMONUMENT PROPERTY CORNERS OR OFFSETSBEFORE GRADING.NO SCALEVICINITY MAPPROJECT SITE1400 W BAY AVE.RAW CUT 0 CUBIC YARDSRAW FILL120 CUBIC YARDSOVER EXCAVATION280 CUBIC YARDSSHRINKAGE 5%±14CUBIC YARDSNET 134 CUBIC YARDS (IMPORT)PA2022-0187
20'LOT 12BLOCK 1 TRACT NO. 626M.M. 30/40-41LOT 11(7.51)FS(7.50)FS(7.48)FS(7.21)FS(7.46)SDMH RIM(7.31)FS(7.21)FS(7.06)FS(7.41)FS(7.71)NG(6.32)NG(3.55)NG(3.62)NG(7.05)
NG
(8.11)
NG(7.47)NG(7.33)FS(7.33)FS(7.35)FS(7.33)TC(6.82)FL(7.31)TC(6.85)FL(7.37)TC(6.95)FL(7.36)TX(7.09)FL(7.53)TX(7.06)FL(7.56)TX(7.13)FL(7.62)TC(7.12)FL(7.09)FL(7.08)FL(7.13)FL(7.11)FL(7.14)FL(7.79)FFG(7.75)FS (7.74)FS(7.95)FS(8.19)FS(7.65)FS(7.66)FS(7.59)FS (34.32)RIDGE(7.73)FFG(7.67)FS(7.65)FS(7.61)FS(7.17)FS(7.42)FS(7.48)FS(7.61)FS(7.68)FS(7.60)FS(8.04)FF(7.69)FS(7.48)FS(7.62)FS(7.58)FS(7.64)
FS
(7.64)
FS
(7.39)
FS(7.57)FS(7.44)FS(7.38)FS(7.40)FS(7.99)FF
(32.00)
CHIMNEY TOP
(6.92)FS(6.97)FS(6.93)FS(6.95)FS(7.48)FS(7.00)FS(6.94)FS(7.50)FS(7.97)FF(7.58)FS(7.38)FS(7.28)FS(7.23)FS(7.17)FS(8.44)TW(7.35)NG(7.21)FS(8.37)TW(8.47)TW(7.01)FS(7.50)FS(7.42)FS(8.44)TW(8.40)TW(7.14)FS(8.42)TW(8.27)TD(8.32)TD(34.90)CHIMNEY TOP(8.23)FS(7.62)FS(7.62)FS(7.66)FS(7.62)FS(7.62)FS(7.60)FS(7.62)FS(8.22)FS(8.65)TW(8.62)FS(7.94)NG(8.72)FS
(7.66)NG (7.69)FSEXISTINGBUILDINGPROPERTYLINEPROPERTYLINEPROPERTYLINEPROPERTYLINE
COLUMNCOLUMNSIGNEMHACUGATEVENTCURBSIGNACUCATVWVGMWMGATE8"PALM8"PALM10"PALM8"PALM12"PALM12"PALMPROPOSED RESIDENCEFF=9.13W BAY AVENUE14TH STREETGFF=8.13GFF=7.92FS=7.86
FF=9.13FF=9.13
FS=8.889.13FF,TOP9.13FF8.63FS6"STEP9.13FF8.88FS3"STEP8.50TW8.50TW10.90TW10.90TW10.90TW10.90TW13.00TW10.90TW10.90TW13.00TW(7.70)FS(7.60)FS1.0%3.1%5.0%(7.47)FS8.13FF7.88FS3"STEPPROPERTY LINESTORAGE AREAFF=8.137.86FS(7.61)FS3.6%7.82FS7.88FS7.88FS7.70TG7.14INV2.0%2.0%2%8.56FS,TOP2%7.54FS,BOT6" STEPS(2 EACH)6" STEPS(2 EACH)7.86FS8.05GFF8.01FS1/2"STEP7.98FL8.01FS,BOT8.85FL,HP8.81TG7.81INV8.84FS,TOP5" STEPS(2 EACH)8.75TG8.85FL,HP8.75TG8.85FL,HP8.75TG7.27INV2.0%2.0%8.57FS8.47FG8.57FS8.47FG2.0%8.57FS8.47FG8.57FS8.57FS8.35TG7.12INV8.24TG6.95INV8.47FG10.65TG2.
0%2.0%2.0%2.
0%
2.
0%2.0%2.0%2.
0%2.0%1.0%1.0%1.0%1.0%1.0%8.88FS8.84FL7.54FS8.04FS6"STEP8.68FS8.18FS6"STEP8.00TG7.10INV8.14FL8.63TG7.21INV1.0%2.0%FIREPIT8.55FSEXISTING DRIVEWAYAPRON TO REMAINEXISTING DOCKTO REMAIN7.56TG6.96INV7.64FS1.0%7.81FL10.65TG10.65TG7.64FSGB GB
GB2.7%444444422211111133338.30TG7.21INV55556788888888810999991010101010101010Δ=00°19'55" R=6039.65' L=34.99'N11°20'38"E 109.89'Δ=00°20'02" R=6119.21' L=35.66'N11°41'17"E 109.90'PROPERTY LINEPROPERTY LINEPROPERTY LINE20'LOT 12BLOCK 1 TRACT NO. 626M.M. 30/40-41LOT 11(7.51)FS(7.50)FS(7.48)FS(7.21)FS(7.46)SDMH RIM(7.31)FS(7.21)FS(7.06)FS(7.41)FS(7.71)NG(6.32)NG(3.55)NG(3.62)NG(7.05)
NG
(8.11)
NG(7.47)NG(7.33)FS(7.33)FS(7.35)FS(7.33)TC(6.82)FL(7.31)TC(6.85)FL(7.37)TC(6.95)FL(7.36)TX(7.09)FL(7.53)TX(7.06)FL(7.56)TX(7.13)FL(7.62)TC(7.12)FL(7.09)FL(7.08)FL(7.13)FL(7.11)FL(7.14)FL(7.79)FFG(7.75)FS (7.74)FS(7.95)FS(8.19)FS(7.65)FS(7.66)FS(7.59)FS (34.32)RIDGE(7.73)FFG(7.67)FS(7.65)FS(7.61)FS(7.17)FS(7.42)FS(7.48)FS(7.61)FS(7.68)FS(7.60)FS(8.04)FF(7.69)FS(7.48)FS(7.62)FS(7.58)FS(7.64)
FS
(7.64)
FS
(7.39)
FS(7.57)FS(7.44)FS(7.38)FS(7.40)FS(7.99)FF
(32.00)
CHIMNEY TOP
(6.92)FS(6.97)FS(6.93)FS(6.95)FS(7.48)FS(7.00)FS(6.94)FS(7.50)FS(7.97)FF(7.58)FS(7.38)FS(7.28)FS(7.23)FS(7.17)FS(8.44)TW(7.35)NG(7.21)FS(8.37)TW(8.47)TW(7.01)FS(7.50)FS(7.42)FS(8.44)TW(8.40)TW(7.14)FS(8.42)TW(8.27)TD(8.32)TD(34.90)CHIMNEY TOP(8.23)FS(7.62)FS(7.62)FS(7.66)FS(7.62)FS(7.62)FS(7.60)FS(7.62)FS(8.22)FS(8.65)TW(8.62)FS(7.94)NG(8.72)FS
(7.66)NG (7.69)FSEXISTINGBUILDINGPROPERTYLINEPROPERTYLINEPROPERTYLINEPROPERTYLINE
COLUMNCOLUMNSIGNEMHACUGATEVENTCURBSIGNACUCATVWVGMWMGATE8"PALM8"PALM10"PALM8"PALM12"PALM12"PALMPROPOSED RESIDENCEFF=9.13W BAY AVENUE14TH STREET7.70TG7.14INV8.81TG7.81INV8.75TG8.75TG8.75TG7.27INV8.35TG7.12INV8.24TG6.95INV10.65TG(7.31)TC6.89INV(6.85)FL10.65TG10.65TG6.88INV-IN8.30TG7.21INV888888888109999910101010101010101111111111121313S=0.01S=0.01S=0.01S=0.0114SUMP PUMPCONNECT FORCEMAIN TO SIDE OFSPEE-D BASIN WITH VERTICAL WYEPER CPC; CONSTRUCT CONCRETECOLLAR AROUND SPEE-D BASIN15Δ=00°19'55" R=6039.65' L=34.99'N11°20'38"E 109.89'Δ=00°20'02" R=6119.21' L=35.66'N11°41'17"E 109.90'2C2GRADING PLAN
PRECISE GRADING PLAN
FOR HEDGE RESIDENCE
1400 W BAY AVENUE
NEWPORT BEACH, CA 92661JOB NO.DATESHEET NO.REVISIONS22039NO. REVISION DATESHEET NO. OF 48/18/202228052 CAMINO CAPISTRANO, STE 213
LAGUNA NIGUEL, CA 92677
949.464.8115 info@civilscapes.com
G:\Projects\22039 1400 W Bay Ave, NB\DWG\22039.GRADING.dwg CONSTRUCTION NOTESHARDSCAPE PER ARCHITECT'S PLAN.DRIVEWAY PER ARCHITECT'S PLAN.PLANTER AREA PER ARCHITECT'S PLAN.WALL OR FENCE PER ARCHITECT'S PLAN.CONSTRUCT FLOWLINE PER DETAIL HEREON.IF EXISTING METER IS SUBSTANDARD, REMOVE AND REINSTALL 1-INCH WATER METER PER CITY OF NEWPORTBEACH STANDARD DRAWING STD 502. PROTECT SERVICE LINE FROM METER TO WATER MAIN. METER ANDSERVICE SIZE SHALL BE CONFIRMED BY MEP CONSULTANT.FIELD VERIFY LOCATION AND CONDITION OF EXISTING SEWER LATERAL TO SATISFACTION OF CITY ENGINEER.REMOVE EXISTING CLEANOUT AND PROVIDE NEW SEWER CLEANOUT WITH TRAFFIC RATED BOX PER CITY OFNEWPORT BEACH STANDARD DRAWING STD 406.CONNECT DOWNSPOUT TO ONSITE STORM DRAIN SYSTEM PER DETAIL ON SHEET PER DETAIL HEREON;OTHERWISE OUTLET TO SURFACE IN DIRECTION OF FLOWFURNISH & INSTALL 6" NDS SPEE-D BASIN W/6" GREEN ATRIUM GRATE PER DETAIL HEREON.FURNISH & INSTALL 6" NDS SPEE-D BASIN W/6" BRASS SQUARE GRATE PER DETAIL HEREON.FURNISH & INSTALL 4-INCH SDR-35 PVC STORM DRAIN (OR APPROVED EQUAL) PER CPC. INCLUDE REQUIREDJOINTS AND FITTINGS PER CPC. CONSTRUCT TRENCH, BEDDING, AND BACKFILL PER ASTM D 2321 AND SOILSREPORT.FURNISH & INSTALL 3-INCH SDR-35 PVC STORM DRAIN (OR APPROVED EQUAL) PER CPC. INCLUDE REQUIREDJOINTS AND FITTINGS PER CPC. CONSTRUCT TRENCH, BEDDING, AND BACKFILL PER ASTM D 2321 AND SOILSREPORT.CONSTRUCT 12 LINEAR FEET OF PERFORATED PIPE AND GRAVEL TRENCH PER DETAIL HEREON.1-1/2" PVC FORCEMAIN; CONNECT TO PUMP DISCHARGE.1234567891011121314LANDSCAPING OR PAVERS3" COVER MINIMUM4" DIA. PERFORATED PVC DRAIN PIPEW/ PERFORATIONS AT BOTTOM3/4" CRUSHED ROCKWRAP SIDES AND BOTTOM OFTRENCH WITH FILTER FABRIC; PROVIDE4" MINIMUM OVERLAP AT TOP OFTRENCHPERFORATED DRAIN PIPE AND TRENCHNO SCALE13GRADING PLANSCALE: 1" = 8'STORM DRAIN PLANSCALE: 1" = 8'3-INCH PVC DOWNSPOUTDRAIN PIPE PER STORM DRAIN PLAN4-INCH ELBOW 1/4 BEND4-INCH PVC RISER WITHDOWNSPOUT INSIDE RISER PIPECLAMPS AROUND RISER PIPE (TYP)PROP. BUILDINGWALLDOWNSPOUT CONNECTION DETAILNO SCALE8TOP OF WALLFINISHED SURFACEFLOW LINEFINISHED GRADEGRADE BREAKHIGH POINTLEGENDINVERTTOP OF GRATEFINISHED FLOOR ELEVATIONTWFSFLFGGBHPINVTGFFTOP OF COPING OR TOP OF CURBTCGARAGE FINISHED FLOORGFFEXISTING GRADEEG EXISTING SPOT ELEVATION( )TOP OF RETAINING WALLTRWTOP OF SLOPETOPTOP OF RAILINGTRTOP OF STEMWALLTSHARDSCAPE PER ARCH. PLANALL WORK RELATED TO WASTEWATER IN THE PUBLIC RIGHT-OF-WAY SHALL BEPERFORMED BY A C-42 LICENSED SANITATION SEWER CONTRACTOR OR AN ALICENSED GENERAL ENGINEERING CONTRACTOR.***ALL WORK RELATED TO WATER IN THE PUBLIC RIGHT-OF-WAY SHALL BEPERFORMED BY A C-34 LICENSED PIPELINE CONTRACTOR OR AN A LICENSEDGENERAL ENGINEERING CONTRACTOR.***********NATURAL GRADENGFL PERPLAN2% MIN.HARDSCAPE/LANDSCAPEPER PLAN2% MIN.FLOWLINE DETAILNO SCALE5PROPERTY LINE AND LIMIT-OF-WORKOREXISTING ELEVATION; CONTRACTOR SHALL FIELDVERIFY ELEVATIONS PRIOR TO CONSTRUCTIONAND REPORT ANY DISCREPANCIES TOCIVILSCAPES ENGINEERING102.6(102.6)PROPOSED WALLBUILDING STEMWALLNDS SPEE-D BASIN DETAILNO SCALE1092% MIN3/4" CRUSHED ROCK OR APPROVEDEQUAL (REVIEW GEOTECHNICALRECOMMENDATIONS IN THE SOILSREPORT TO VERIFY)DRAIN PIPE PER PLANCOMPACTED BACKFILLPER GEOTECHNICALRECOMMENDATIONSCOMPACTED BEDDINGPER GEOTECHNICALRECOMMENDATIONSNATIVE OR RE-COMPACTED SUBGRADE4" MIN4" MIN4" MIN NDS #101 OR #201SPEE-D BASINOR APPROVEDEQUALNDS #66 - 6" DRAIN RISER PIPE (LENGTHAS REQUIRED) OR APPROVED EQUALVARIES 2% MINNDS ATRIUM OR FLAT GRATETG ELEVPER PLANINV ELEVPER PLANSLOPE PER PLANPA2022-0187
20'LOT 12BLOCK 1 TRACT NO. 626M.M. 30/40-41LOT 11(7.51)FS(7.50)FS(7.48)FS(7.21)FS(7.46)SDMH RIM(7.31)FS(7.21)FS(7.06)FS(7.41)FS(7.71)NG(6.32)NG(3.55)NG(3.62)NG(7.05)
NG
(8.11)
NG(7.47)NG(7.33)FS(7.33)FS(7.35)FS(7.33)TC(6.82)FL(7.31)TC(6.85)FL(7.37)TC(6.95)FL(7.36)TX(7.09)FL(7.53)TX(7.06)FL(7.56)TX(7.13)FL(7.62)TC(7.12)FL(7.09)FL(7.08)FL(7.13)FL(7.11)FL(7.14)FL(7.79)FFG(7.75)FS (7.74)FS(7.95)FS(8.19)FS(7.65)FS(7.66)FS(7.59)FS (34.32)RIDGE(7.73)FFG(7.67)FS(7.65)FS(7.61)FS(7.17)FS(7.42)FS(7.48)FS(7.61)FS(7.68)FS(7.60)FS(8.04)FF(7.69)FS(7.48)FS(7.62)FS(7.58)FS(7.64)
FS
(7.64)
FS
(7.39)
FS(7.57)FS(7.44)FS(7.38)FS(7.40)FS(7.99)FF
(32.00)
CHIMNEY TOP
(6.92)FS(6.97)FS(6.93)FS(6.95)FS(7.48)FS(7.00)FS(6.94)FS(7.50)FS(7.97)FF(7.58)FS(7.38)FS(7.28)FS(7.23)FS(7.17)FS(8.44)TW(7.35)NG(7.21)FS(8.37)TW(8.47)TW(7.01)FS(7.50)FS(7.42)FS(8.44)TW(8.40)TW(7.14)FS(8.42)TW(8.27)TD(8.32)TD(34.90)CHIMNEY TOP(8.23)FS(7.62)FS(7.62)FS(7.66)FS(7.62)FS(7.62)FS(7.60)FS(7.62)FS(8.22)FS(8.65)TW(8.62)FS(7.94)NG(8.72)FS
(7.66)NG (7.69)FSEXISTINGBUILDINGPROPERTYLINEPROPERTYLINEPROPERTYLINEPROPERTYLINE
COLUMNCOLUMNSIGNEMHACUGATEVENTCURBSIGNACUCATVWVGMWMGATE8"PALM8"PALM10"PALM8"PALM12"PALM12"PALMPROPOSED RESIDENCEFF=9.13W BAY AVENUE14TH STREETΔ=00°19'55" R=6039.65' L=34.99'N11°20'38"E 109.89'Δ=00°20'02" R=6119.21' L=35.66'N11°41'17"E 109.90'FACE OF PROP. BLDG WALL
FF=9.13FACE OF PROP. BLDG WALLFF=9.13SECTION A-ASCALE: 1"=4'EXISTINGGROUNDEXISTINGGROUNDP/LEXISTINGBUILDING(ADJACENTNEIGHBOR)(8.2)FS8.81TG13.00TWREMOVE AND REPLACEEXISTING WALL PERARCH. PLAN7.56TG8.50TW(7.48)FS(7.31)TC(6.85)FLP/LEXISTINGGROUNDPROPOSED WALLPER ARCH. PLANEXISTING STREETIMPROVEMENTSTO REMAINOVER-EXCAVATION LIMITS PERGEOTECHNICAL RECOMMENDATIONSAND TO BE VERFIED IN FIELD BY SOILSENGINEERTEMPORARY 1:1 SLOPETO OVER-EX3'±
3'±TEMPORARY 1:1 SLOPETO OVER-EXFACE OF PROP. BLDG WALL
FF=9.138.13GFF7.92GFF7.88FS(7.67)FSP/L(7.13)FS(7.09)FLEXISTING DRIVEWAYAPRON TO REMAIN1.0%4.1%SECTION B-BSCALE: 1"=4'EXISTINGGROUNDOVER-EXCAVATION LIMITS PERGEOTECHNICAL RECOMMENDATIONSAND TO BE VERFIED IN FIELD BY SOILSENGINEERTEMPORARY 1:1 SLOPETO OVER-EX3'±FACE OF PROP. BLDG WALLFF=9.138.88FS8.57FS8.47FG10.90TW10.90TW(8.47)TW10.65FGP/LEXISTING SEAWALLTO REMAIN;PROTECT IN PLACEPROPOSED WALLPER ARCH. PLAN2.0%EXISTINGGROUNDSECTION C-CSCALE: 1"=4'OVER-EXCAVATION LIMITS PERGEOTECHNICAL RECOMMENDATIONSAND TO BE VERFIED IN FIELD BY SOILSENGINEER3'±TEMPORARY 1:1 SLOPETO OVER-EX3C3EROSION CONTROL PLAN
PRECISE GRADING PLAN
FOR HEDGE RESIDENCE
1400 W BAY AVENUE
NEWPORT BEACH, CA 92661JOB NO.DATESHEET NO.REVISIONS22039NO. REVISION DATESHEET NO. OF 48/18/202228052 CAMINO CAPISTRANO, STE 213
LAGUNA NIGUEL, CA 92677
949.464.8115 info@civilscapes.com
G:\Projects\22039 1400 W Bay Ave, NB\DWG\22039.GRADING.dwg 1. CONTRACTOR SHALL PROVIDE ONSITE CONCRETE WASHOUT FACILITY AND COMPLY WITHCASQA BMP WM-8.2. ALL REMOVABLE EROSION PROTECTIVE DEVICES SHALL BE IN PLACE AT THE END OF EACHWORKING DAY WHEN THE 5-DAY RAIN PROBABILITY FORECAST EXCEEDS 40%.3. SEDIMENTS FROM AREAS DISTURBED BY CONSTRUCTION SHALL BE RETAINED ON SITE USINGAN EFFECTIVE COMBINATION OF EROSION AND SEDIMENT CONTROLS TO THE MAXIMUM EXTENTPRACTICABLE, AND STOCKPILES OF SOIL SHALL BE PROPERLY CONTAINED TO MINIMIZE SEDIMENTTRANSPORT FROM THE SITE TO STREETS, DRAINAGE FACILITIES OF ADJACENT PROPERTIES VIARUNOFF, VEHICLE TRACKING, OR WIND.3. APPROPRIATE BMPS FOR CONSTRUCTION-RELATED MATERIALS, WASTES, SPILLS OR RESIDUESSHALL BE IMPLEMENTED AND RETAINED ON SITE TO MINIMIZE TRANSPORT FROM THE SITE TO STREETS, DRAINAGE FACILITIES, OR ADJOINING PROPERTY BY WIND OR RUNOFF. NOTES:GRAVEL BAG DETAILNO SCALEAEROSION CONTROL CONSTRUCTION NOTESINSTALL GRAVEL BAG BARRIER PER CASQA SE-8 AND SE-6INLET PROTECTION PER DETAIL HEREONABAREA DRAIN INLET PROJECTIONNO SCALEBAAAABBBBBBBBBBBBBBPA2022-0187
4C4GEOTECHNICAL NOTES
PRECISE GRADING PLAN
FOR HEDGE RESIDENCE
1400 W BAY AVENUE
NEWPORT BEACH, CA 92661JOB NO.DATESHEET NO.REVISIONS22039NO. REVISION DATESHEET NO. OF 48/18/202228052 CAMINO CAPISTRANO, STE 213
LAGUNA NIGUEL, CA 92677
949.464.8115 info@civilscapes.com
G:\Projects\22039 1400 W Bay Ave, NB\DWG\22039.GRADING.dwg PA2022-0187
LAWN
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L LL L
LAVANDULA SPP. LAVENDER (LOW WATER USE)
PLANT LEGEND
L
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
BRANDON ARCHITECTS
2/16/2022
LANDSCAPE
PLANTING PLANHEDGE RESIDENCEEDDIE AND DESIREE HEDGE
1400 W. BAY AVENUE
NEWPORT BEACH, CA 92661
DD
1400 W. BAY AVENUE
L-0
**0000-2021**
JEFF VAN VOORHIS
NO. REVISION DATE
3/16" = 1'-0"1 SCHEMATIC LANDSCAPE PLAN
LANDSCAPE NOTES:
1. ENCOARCHMENT PERMIT REQ'D. FOR ANY WORK PROPOSED IN THE PUBLIC R.O.W.
2. IF APPLICABLE, REF. PRELIMINARY LANSCAPE PLAN, FOR ALL HARDSCAPE & PLANTING AREAS WITH REPECTIVE HEIGHTS AND MATERIALS.
GENERAL MATERIAL SPECIFICATION:
1. GROUT CELLS WITH REINFORCED CEMENT PER ASTM C150. 1 PART PORTLAND CEMENT, 2 TO 3 PARTS LOOSE SAND, 2 PARTS COARSE AGGREGATE.
2. REINFORCING: FS = 20,000 PSI ASTM A615 GRADE 40.
3. MASONRY: FC = 1,500 PSI GRADE 'A' PER ASTM C150.
4. CONCRETE: FC = 3,500 PSI AT 28 DAYS CEMENT PER ASTM C150.
5. POUR ALL WALL FOOTINGS AGAINST NATURAL UNDISTURBED EARTH.
6. TELEPHONE LANDSCAPE ARCHITECT IF SITE CONDITIONS ARE NOT AS SHOWN.
PROJECT HARDSCAPE MATERIALS:
STONE SHOULD MATCH THE STONE USED ON THE HOUSE.
PAVING STONE SHALL BE SHADOW GRAY SANDSTONE/QUARTZITE.
ALL GROUT JOINTS SHALL BE PIGMENTED PER ARCH./G.C. APPROVAL.
ALL HARDSCAPE MATERIAL SHALL RECEIVE 6 MIL. VISQUEEN ON UNDER SIDE FOR WATERPROOF PROTECTION.
TOTAL LANDSCAPING AREA:
PA2022-0187
DN
DN
DN
DNCL
CL
25'20'LOT 12
BLOCK 1
TRACT NO. 626
M.M. 30/40-41
LOT 11
W. BAYAVENUE14TH
STREET N11°41'17"E 134.90'
N11°20'38"E 109.89'
N11°41'17"E 109.90'
[BASIS OF BEARINGS]Δ=00°11'14" R=6119.21'L=20.00'Δ=00°20'02" R=6119.21' L=35.66'Δ=00°19'55" R=6039.65' L=34.99'(7.51)
FS
(7.50)
FS
(7.48)
FS
(7.21)
FS
(7.46)
SDMH RIM (7.31)
FS (7.21)
FS (7.06)
FS
(7.41)
FS
(7.71)
NG
(6.32)
NG (3.55)
NG
(3.62)
NG
(7.05)NG(8.11)NG(7.47)
NG(7.33)
FS
(7.33)
FS
(7.35)
FS
(7.33)TC
(6.82)FL
(7.31)TC
(6.85)FL
(7.37)TC
(6.95)FL
(7.36)TX
(7.09)FL
(7.53)TX
(7.06)FL
(7.56)TX
(7.13)FL
(7.62)TC
(7.12)FL
(7.09)
FL
(7.08)
FL
(7.13)
FL
(7.11)
FL
(7.14)
FL
(7.79)
FFG(7.75)FS(7.74)
FS (7.95)
FS
(8.19)
FS
(7.65)
FS
(7.66)
FS
(7.59)FS(34.32)
RIDGE
(7.73)
FFG
(7.67)
FS
(7.65)
FS
(7.61)
FS
(7.17)
FS
(7.42)
FS
(7.48)
FS
(7.61)
FS
(7.68)
FS
(7.60)
FS
(8.04)
FF
(7.69)
FS
(7.48)
FS
(7.62)
FS (7.58)
FS (7.64)FS(7.64)FS(7.39)FS(7.57)
FS
(7.44)
FS(7.38)
FS (7.40)
FS (7.99)FF(32.00)CHIMNEY TOP(6.92)
FS
(6.97)
FS
(6.93)
FS
(6.95)
FS
(7.48)
FS
(7.00)
FS
(6.94)
FS
(7.50)
FS
(7.97)
FF
(7.58)
FS
(7.38)
FS
(7.28)
FS
(7.23)
FS
(7.17)
FS
(8.44)
TW
(7.35)
NG
(7.21)
FS
(8.37)
TW (8.47)
TW
(7.01)
FS
(7.50)
FS
(7.42)
FS
(8.44)
TW
(8.40)TW
(7.14)FS
(8.42)
TW (8.27)
TD
(8.32)
TD
(8.29)
TD
(8.29)
TD
(32.01)
RIDGE
(33.44)
RIDGE
(34.90)
CHIMNEY TOP
(8.23)
FS
(7.62)
FS (7.62)FS (7.66)FS(7.62)
FS
(7.62)
FS
(7.60)
FS
(7.62)
FS
(8.22)
FS
(8.65)
TW
(8.62)FS
(7.94)NG (8.72)FS(7.66)NG(7.69)
FS
EXISTING
BUILDING
EXISTING
BUILDING
PROPERTY
LINE
PROPERTY
LINE
PROPERTY
LINEPROPERTYLINE COLUMN
COLUMN
SIGN
EMH
ACU
GATE
VENT
CURB
SIGN
ACU
CATVWV
GM
WM
GATE
8"
PALM
8"
PALM
10"
PALM
8"
PALM
12"
PALM
12"
PALM
ROOM TAGROOM NAME
?
1
10.00'SPOT ELEVATION
KEYNOTE TAG
REVISION TAG
PROPERTY LINE TAG90 00' 00"20.00'N E
FIREPIT -AS SELECTED TO BE LISTED AND APPROVED, VERIFY W/.
OWNER –PROVIDE POWER AND GAS AS REQUIRED –INSTALL AND
MAINTAIN CLEARANCES PER MFGR. AND SECTION 308 OF CFC
RECESSED MAIN SERVICE PANEL -400 AMP MAX. (MAINTAIN 36" CLEAR FROM FACE
OF PANEL TO ANY OBSTRUCTION) –GC TO COORDINATE W/. UTILITY COMPANY
A/C CONDENSER / HEAT PUMP -TO BE IN COMPLIANCE OF SECTION 307.3 OF CPC AS
SELECTED, VERIFY W/. OWNER -SIZE TBD, SEE T-24 ENERGY REPORT FOR MORE INFO –
PROVIDE POWER AND SOUND DAMPENING PAD AS REQ’D. –INSTALL AND MAINTAIN
REQUIRED CLEARANCES PER MFGR. INSTRUCTION
VERTICAL STORM DRAIN PIPE IN-WALL / OVERFLOW -MTL. PIPE PER
CHAPTER 11 OF CPC, SIZE PER TABLE 1103.1 (MIN. 2”DIA. PIPE & TYP. 3”DIA. PIPE) –
SEE CIVIL DWGS. FOR TERMINATION DTLS. ABV. OR BLW. GROUND. VERIFY ALL
TERMINATION POINTS, TYPE AND DETAILS W/. CIVIL PRIOR TO POURING THE CONCRETE
SLAB
OVERFLOW
DRAINLINE
UP
EXT. STAIRS -MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE ARTIFICIAL LIGHT
SOURCE AT THE TOP LANDING AND FOR STAIR TO THE BASEMENT AT BOTH TOP
AND BOTTOM LANDING (R303.8) -REF. DTL. 3/AD-1 -VERIFY TREADS DEPTH AND
RISERS HT. W/. CIVIL AND LANDSCAPE DWGS
DIMENSION NOTE:
ALL DIMENSIONS ARE TO FACE OF SHEATHING (EXT. WALLS) OR FACE OF STRUCTURE (F.O.S.) TYP. U.N.O. ROUNDED TO THE
NEAREST 1/8" AND INTERIOR PARTITIONS ARE DIMENSIONED FROM FACE OF STRUCTURE TO FACE OF STRUCTURE (F.O.S.)
U.N.O. -CONTACT ARCHITECT IN WRITING FOR ANY CLARIFICATION OF NOTED DIMENSIONS, DO NOT SCALE PLANS.
GENERAL NOTE:
SEE SHEET A-3.0 FOR ROOF PLAN INFORMATION NOT SHOWN ON THIS SHEET (INCLUDING EAVE DETAILS AND PROJECTION
DISTANCES).
C.N.B. NOTES:
1. ISSUANCE OF A BUILDING PERMIT BY THE CITY OF NEWPORT BEACH DOES NOT RELIEVE APPLICANTS OF THE LEGAL
REQUIREMENTS TO OBSERVE COVENANTS, CONDITIONS AND RESTRICTIONS WHICH MAY BE RECORDED AGAINST THE PROPERTY
OR TO OBTAIN PLANS YOU SHOULD CONTACT YOUR COMMUNITY ASSOCIATIONS PRIOR TO COMMENCEMENT OF ANY
CONSTRUCTION AUTHORIZED BY THIS PERMIT.
2. PRIOR TO PERFORMING ANY WORK IN THE CITY RIGHT-OF-WAY AN ENCROACHMENT PERMIT MUST BE OBTAINED FROM THE
PUBLIC WORKS DEPARTMENT.
3. A CAL-OSHA PERMIT IS REQUIRED FOR EXCAVATIONS DEEPER THAN 5' AND FOR SHORING AND UNDERPINNING.
4. ELECTRICAL SERVICE TO BE UNDERGROUND FOR NEW CONSTRUCTION, REPLACEMENT BUILDING OR ADDITIONS TO AN
EXISTING BUILDING EXCEEDING 50% OF THE GROSS FLOOR AREA OF THE EXISTING BUILDING. (NBMC 12.32.015)
5. FIELD INSPECTOR TO REVIEW AND APPROVE UNDERGROUND ELEC. SERVICE REQUIREMENT PRIOR TO CONCRETE PLACEMENT.
6. EDISON COMPANY APPROVAL IS REQUIRED FOR METER LOCATION PRIOR TO INSTALLATION.
LANDSCAPE NOTES:
1. ENCROACHMENT PERMIT REQ'D. FOR ANY WORK PROPOSED IN THE PUBLIC R.O.W.
2. IF APPLICABLE, REF. PRELIMINARY LANDSCAPE PLANS, FOR ALL HARDSCAPE & PLANTING AREAS WITH RESPECTIVE HEIGHTS
AND MATERIALS.
POOL:
1. PROVIDE AN ALARM FOR DOORS AND WINDOWS WITH SILL HEIGHTS LESS THAN 60-INCHES ABV.F.F. OF THE DWELLING THAT
FORMS A PART OF THE POOL ENCLOSURE. THE ALARM SHALL BE LISTED AS A WATER HAZARD ENTRANCE ALARM IN
ACCORDANCE WITH UL 2017. THE DEACTIVATION SWITCH SHALL BE AT LEAST 60" ABOVE THE FLOOR IF THE RESIDENCE IS NOT
REQUIRED TO BE ACCESSIBLE. (CBC 3109 & ISPSC 305.4)
2. SUCTION OUTLETS SHALL BE DESIGNED AND INSTALLED WITH SUCTION ANTIENTRAPMENT GRATE IN ACCORDANCE WITH
ANSI/APSP-16 PER CBC 3109 SECTION (B) OF 115928. SUCTION ENTRAPMENT AVOIDANCE FOR POOL AND SPA SHALL BE
PROVIDED IN ACCORDANCE WITH APSP-7 PER ISPSC SECTION 310.
3. PROVIDE POWER SAFETY COVER IN COMPLIANCE WITH ASTM F1346-91 FOR POOL & SPA (CBC 3109 SECTION (3) OF 115922 &
ISPSC 305).
4. POOL ENCLOSURE FENCE SHALL BE 60-INCHES MIN. ABV. FS/NG MEASURED ON THE SIDE THAT FACES AWAY FROM
SWIMMING POOL W/. MAX VERTICAL CLEARANCE OF 2-INCHES BETWEEN FS/NG AND BOTTOM OF THE FENCE/BARRIER
MEASURED ON THE SIDE OF FENCE THAT FACES AWAY FROM SWIMMING POOL. OPENING, GAP, AND VOID IN ENCLOSURE FENCE
OR GATE SHALL NOT ALLOW THE PASSAGE OF 4-INCHES DIAMETER SPHERE OR LARGER. OUTSIDE SURFACE (FACING AWAY
FROM SWIMMING POOL) OF THE POOL ENCLOSURE INCLUDING THE GATE TO BE FREE OF PROTRUSIONS, CAVITIES, OR OTHER
PHYSICAL CHARACTERISTICS THAT WOULD SERVE AS HANDHOLDS OR FOOTHOLDS WHICH COULD ENABLE A CHILD FIVE YEARS
OLD OR YOUNGER TO CLIMB OVER. (CBC 3109 & ISPSC 305)CLR.21' - 8 3/4"CLR.
19' - 10 3/8"
1
1
1
1
2
3
4
5
5 3
6
6
6
7
8
9 1010 10
10
9DININGLOUNGE
GREAT ROOMKITCHEN
PANTRY
PWDR.
FOYER
2-CAR GARAGE
STORAGE
C/C.
9.13' FIRST LEVEL F.F.
SLOPE PER CIVIL
9.13' FIRST LEVEL F.F.8.83' F.F.
11
12
13
14
10
15
16
17
8.50' T.W.8.50' T.W.10.90' T.W.10.90' T.W.
10.90' T.W.
13.00' T.W.
17
18
19
20 2020
19
10.90' T.W.S.Y.S.B.3' - 0"S.Y.S.B.3' - 0"R.Y.S.B.
25' - 0"
F.Y.S.B.
5' - 0"
ENTRY
21
22
22
22
22
23 23
BEACH -NOT A PART14TH STREET
W. BAY AVENUE
ADJACENT PROPERTY -NOT A PART
PLANTERPLANTEREXISTING DOCK
REFERENCE SEAWALL
PLANS SW-0, SW-1, SW-2
FOR PROPOSED SEAWALL
PT. 1
7.51
PT. 4
6.97
PT. 2
7.75
PT. 4
7.67
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
SITE PLAN NOTESA
ANNOTATION LEGENDB
KEYNOTESC
BRANDON ARCHITECTS
2/16/2022
ARCHITECTURAL
SITE PLANHEDGE RESIDENCEEDDIE AND DESIREE HEDGE
1400 W. BAY AVENUE
NEWPORT BEACH, CA 92661
DD
1400 W. BAY AVENUE
A-0.0
**0000-2021**
JEFF VAN VOORHIS
PROJECT NORTHTRUE NORTH
3/16" = 1'-0"1 ARCHITECTURAL SITE PLAN
1 PROPERTY LINE
2 FRONT YARD SETBACK
3 SIDE YARD SETBACK
4 REAR YARD SETBACK
5 (N.) PROPERTY LINE WALL - PLASTER FINISH TO MATCH (MAX. 6' ABV. N.G.)
6 (N.) WOOD GATE - AS SELECTED (MAX. 6' HT. ABOVE NATURAL GRADE)
7 (N.) CONCRETE STEPS ON GRADE - REF. CIVIL DWGS.
8 (N.) 18" LANDSCAPE WALL. REF. LANDS. DWGS.
9 PLANTED AREA - COORDINATE WITH LANDSCAPE DESIGNER
10 (N.) HARDSCAPE - STONE PAVERS (AS SELECTED), REF. LAND. DWGS.
11 (E.) WATER VALVE - (REF. SURVEY & CIVIL DWGS.)
12 (E.) WATER METER LOCATION - (REF. SURVEY & CIVIL DWGS.)
13 (E.) GAS METER LOCATION - (REF. SURVEY & CIVIL DWGS.)
14 (E.) CABLE TV JUNCTION BOX (REF. SURVEY & CIVIL DWGS.)
15 WOOD SCREEN, PAINT & SEAL AS SEL. - ARCH. TO APPV. - SIZE & CONN. PER STRUCT.
16 DOWNSPOUT - ALUMINUM W/. KYNAR FINISH OR EQUIV. - AS SEL. (ARCH. TO APPROVE)
17 CURB
18 (E.) ELECTRICAL MANHOLE
19 (E.) STREET SIGN - PROTECT IN PLACE
20 (E.) LANDSCAPE WALL. REF. LANDS. DWGS.
21 EXISTING STRUCTURE - NOT A PART
22 OUTLINE OF EXISTING STRUCTURE - TO BE DEMOLISHED
23 (E.) A/C. CONDENSER UNIT - TO BE REMOVED
NO. REVISION DATE
1/8" = 1'-0"2 GRADE PLANE EXHIBIT
PT. 1 7.51
PT. 2 7.75
PT. 3 7.67
PT. 4 6.97
29.9/4 = 7.475
GRADE PLANE = 7.475'
PA2022-0187
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
BRANDON ARCHITECTS
2/16/2022
3D VIEWSHEDGE RESIDENCEEDDIE AND DESIREE HEDGE
1400 W. BAY AVENUE
NEWPORT BEACH, CA 92661
DD
1400 W. BAY AVENUE
A-1.0
**0000-2021**
JEFF VAN VOORHIS
NO. REVISION DATE
2 AXONOMETRIC - E1AXONOMETRIC - N
4 AXONOMETRIC - S3AXONOMETRIC - W
PA2022-0187
DN
DN
DN
A-4.0
1
2
A-5.0
2
A-5.0
A-4.02
A-4.0
4
A-4.0 3
4
A-5.0
4
A-5.0
1
A-5.0
1
A-5.0
3
A-5.0
3
A-5.0
1
A-5.1
1
A-5.1
2
A-5.1
2
A-5.1
3
A-5.1
3
A-5.1
4
A-5.1
4
A-5.1
2 3 41CLR.21' - 11 1/2"CLR.
20' - 0"
7
1
3 8
2
9
DININGLOUNGE
GREAT ROOM
KITCHEN
PANTRY
PWDR.
FOYER
5
2-CAR GARAGE
STORAGE
4
C/C.
10
6
S.Y.S.B.3' - 0"S.Y.S.B.3' - 0"F.Y.S.B
5' - 0"
R.Y.S.B.
25' - 0"
R @ 0' -7 5/16"16
TYP.11"CLR.
3' - 6"
CLR.
3' - 6"CLR.3' - 6"CLR.
3' - 6"CLR.3' - 6"CLR.
3' - 6"TYP.11"1
1
2
3
3
4
5
6
7
8
9
T.V.
10
-
---
ROOM TAGROOM NAME
1
A-5.0
1 1
?
1
1
A-4.0
1
1 1
1
ELEVATION / SECTION INDICATOR
AD-1.0
1 CALL-OUT TAG
10.00'SPOT ELEVATION
KEYNOTE TAG
REVISION TAG
DOOR / WINDOW / WINDOW WALL TAG
FIRE RATED CEILING ASS'Y -REF. DTLS. 7/AD-1.0
1-HR RATED INT CONDITION -REF. DTLS. 7/AD-1.0
1-HR RATED EXT CONDITION -REF. DTLS. 7/AD-1.0
STRUCTURAL STEEL COLUMN PER STRUCT., REF. STRUTC.
DWGS, -PAINT AND SEAL AS REQUIRED –ARCH. TO APPV.
COLOR FOR EXPOSED STEEL COLUMNS
STRUCTURAL WOOD POST/COLUMN COLUMN -PER STRUCT., REF. STRUTC. DWGS, -
PAINT, STAIN AND SEAL AS REQUIRED –ARCH. TO APPV. PAINT COLOR FOR EXPOSED
WOOD POST/COLUMN, IF TO BE STAINED PROVIDE STAINED SAMPLE FOR ARCH,
APPROVAL
DOORS -AS SPECIFIED, SEE WINDOW SCHEDULE AND GENERAL NOTES ON SHEET A-7.0 -
SHGC & U-FCTOR PER T-24 ENERGY REPORT – SEE SHEET AD-2.0 FOR JAMB, HEAD AND
THRESHOLD DETAILS, PROVIDE FLASHING AND WATERPROOFING AT DOOR OPENING PER
THE DOOR MFGR. INSTRUCTION AND/OR FLASHING MFGR. INSTRUCTION PER SECTIONS
R609.1 & R703.4 OF CRC
WINDOW -AS SPECIFIED, SEE WINDOW SCHEDULE AND GENERAL NOTES ON
SHEET A-7.0 -SHGC & U-FCTOR PER T-24 ENERGY REPORT – SEE SHEET
AD-2.0 FOR JAMB, HEAD AND SILL DETAILS, PROVIDE FLASHING AND
WATERPROOFING AT WINDOW OPENING PER THE WINDOW MFGR.
INSTRUCTION AND/OR FLASHING MFGR. INSTRUCTION PER SECTIONS R609.1
& R703.4 OF CRC
KITCHEN RANGE W/. EXHAUST HOOD -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –
PROVIDE POWER AND GAS AS REQUIRED -30”MIN. VERTICAL CLEARANCE TO ANY
COMBUSTIBLE MATERIAL ABV. COOKING TOP (CMC 920.3.2) –EXHAUST HOOD TO HAVE
EXHAUST RATE OF MIN. 100 CFM AND VENT TO OUTDOOR , HOOD DUCTS TO BE OF
METAL WITH SMOOTH INTERIOR FINISH PER SECTION 504.3 OF CMC
KITCHEN/BAR SINK -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –SINK TO COMPLY
W/. REQUIREMENT OF SECTION 420.0 OF CPC AND HAVE A MAX FLOW RATE OF 1.8 GPM
@ 60 PSI PER SECTION 4.303.1 OF CALGREEN –TRAP AND VENT FOR ISLAND SINK AND
SIMILAR EQUIPMENT SHALL BE PER SECTION 909.0 OF CPC
VANITY SINK -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –
LAVATORY TO HAVE 24”MIN. CLEAR SPACE IN FRONT OF IT.(CPC 402.5)
W/. MAXIMUM FLOW RATE OF 1.2 GPM @ 60 PSI AND MIN. FLOW RATE OF
0.8 GPM @ 20 PSI PER SECTION 4.303.1 OF CALGREEN
WASHER (W) / DRYER (D) / STACKED (W/D)-AS SELECTED PER I.D., VERIFY W/. I.D. &
OWNER –PROVIDE POWER , GAS, WATER SUPPLY & DRAINAGE AS REQUIRED -THE
CLOTHES DRYERS VENT SHALL BE OF A RIGID METALLIC MATERIAL AND HAVE A
BACKDRAFT DAMPER (CMC 504.4) AND SHALL NOT EXCEED 14-FEET IN OVERALL LENGTH
WITH MAX. OF TWO (2) 90-DEGREE ELBOW, SUBTRACT 2-FEET FOR EACH ADDITIONAL 90-
DEGREE ELBOW. SEE WASHER & DRYER NOTES, REF. T-1.1.
REFRIGERATOR (REF) / FREEZER (FRZ) -AS SELECTED PER I.D., VERIFY W/. I.D. &
OWNER –PROVIDE POWER AND WATER SUPPLY AS REQUIRED
BUILT-IN APPLIANCE / DISHWASHER (DW) / TRASH COMPACTOR (TR)-AS SELECTED PER
I.D., VERIFY W/. I.D. & OWNER –PROVIDE POWER , WATER SUPPLY & DRAINAGE PIPE AS
REQUIRED
TOILET -WATER CLOSET SHALL BE IN COMPLIANCE OF SECTION 411.0 OF CPC AND HAS
MAX EFFECTIVE FLUSH RATE OF 1.28 GAL. PER FLUSH (CPC 411.2). WATER CLOSETS
CLR. TO BE 24”IN FRONT AND 15”FROM ITS CENTER TO ANY SIDE WALL OR
OBSTRUCTION. (CPC 402.5 & CRC R307) –REF. CALGREEN NOTES ON T SHTS. FOR MAX
FLOW RATE
CASEWORK, TALL CABINET -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER
CASEWORK, BASE CABINET W/. COUNTERTOP -AS SELECTED PER I.D., VERIFY W/. I.D. &
OWNER
CASEWORK, UPPER CABINET/SHELVES -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER
BUILT-IN CLOSET -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER
FIREPLACE -FACTORY-BUILT DIRECT VENT GAS FIREPLACE W/. SEALED COMBUSTION
(CALGREEN 4.503) -FACTORY-BUILT FIREPLACES, CHIMNEYS AND ALL OF THEIR
COMPONENTS SHALL BE LISTED AND INSTALLED IN ACCORDANCE WITH THEIR LISTING
AND MANUFACTURER'S INSTALLATION INSTRUCTIONS. (CRC R1004.1)
ELEVATOR -PRIVATE RESIDENCE ELEVATOR IN COMPLIANCE W/. ASME A17.1/CSA B44
AS SELECTED PER PLANS, VERIFY W/. OWNER –PROVIDE POWER AS REQ'D. (CRC 321.1)
A/C CONDENSER / HEAT PUMP -TO BE IN COMPLIANCE OF SECTION 307.3 OF CMC AS
SELECTED, VERIFY W/. OWNER -SIZE TBD, SEE T-24 ENERGY REPORT FOR MORE INFO –
PROVIDE POWER AND SOUND DAMPENING PAD AS REQ’D. –INSTALL AND MAINTAIN
REQUIRED CLEARANCES PER MFGR. INSTRUCTION
FAU -PROVIDE GAS S.O., POWER, AND VENTING AS REQ'D. BY MFG'R. –INSTALL PER
MFGR. INSTRUCTION
ROOF/DECK DRAIN -PER CHAPTER 11 OF CPC -SIZE THE DRAIN AND PIPING PER TABLE
1103.1 AND 1103.2 OF CPC –ROOF DRAIN SHALL HAVE DOMED STRAINER (CPC 1102.2) –
REF. DETAIL 11/AD-1.0
OVERFLOW OR EMERGENCY DRAIN -PER CHAPTER 11 OF CPC -COPPER OR EQ., INSTALL
PER MFGR. INSTRUC., SLOPED TOWARD IN-WALL DRAIN INLETS –SLOPE AND SIZE PER
TABLE 1103.3 OF CPC –REF. DTL. 11/AD-1.0
UP
20R@7 1/2"STAIRS -MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE AN ILLUMINATION LEVEL OF NOT
LESS THAN 1 FOOT CANDLE AS MEASURED AT THE CENTER OF TREADS AND
LANDING WITH ARTIFICIAL LIGHTING (R303.7) -REF. DTL. 3/AD-1
A-4.0
1
2
A-5.0
2
A-5.0
A-4.02
A-4.0
4
A-4.0 3
4
A-5.0
4
A-5.0
1
A-5.0
1
A-5.0
3
A-5.0
3
A-5.0
1
A-5.1
1
A-5.1
2
A-5.1
2
A-5.1
3
A-5.1
3
A-5.1
4
A-5.1
4
A-5.1
5 1 11
8
20
13
11
12
22
MECH.
1615 23
21
BATH #2
BED #2
HALLWAY
BATH #3
BED #3
BED #4
BATH #4
PRIMARY W.I.C.
LAUNDRY
W/C.
PRIMARY BATH
PRIMARY BEDROOM
17
14
21
C/C.
ELEV.
24
6 5
18
19
3 4
7
8
91012
6
7
13 PLANTER AREA1
1
2
3
3
4S.Y.S.B.3' - 0"S.Y.S.B.3' - 0"F.Y.S.B.
5' - 0"
5
6
R @ 0' -7 5/8"16
CLR.3' - 6"CLR.
3' - 6"CLR.3' - 6"CLR.
3' - 6"TYP.11"CLR.
3' - 6"
CLR.
3' - 6"
8
77
9
9
9
8
8
7
7
8
9
11
8
R.Y.S.B.
25' - 0"
2
12 12 12
12
13
-
---
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
KEYNOTESB
ANNOTATION LEGENDA
BRANDON ARCHITECTS
2/16/2022
FIRST & SECOND
LEVEL FLOOR PLANSHEDGE RESIDENCEEDDIE AND DESIREE HEDGE
1400 W. BAY AVENUE
NEWPORT BEACH, CA 92661
DD
1400 W. BAY AVENUE
A-2.0
**0000-2021**
JEFF VAN VOORHIS
1/4" = 1'-0"1 FIRST LEVEL FLOOR PLAN
1 PROPERTY LINE
2 FRONT YARD SETBACK
3 SIDE YARD SETBACK
4 REAR YARD SETBACK
5 STAIRS - MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS THAN 1 FOOT
CANDLE (CBC 1205.4) REF. DTL. 3/AD-1
6 INTERIOR GLASS GUARDRAIL - MIN. 42" HIGH - MATERIAL AS SELECTED, <4" MAX. SPHERE OPENING, REF. DTL. 4/AD-1
7 DEPRESS STRUCTURE FOR FLUSH SHOWER CONDITION - COORD. WITH I.D. & GENERAL CONTRACTOR, REF. STRUCT. DWGS.
8 CUSTOM SHOWER SEAT PER I.D.
9 SHOWER - PROVIDE TILE W/. CEMENT BACKING MIN. 72" HIGH (R307.2)
10 1-1/2" MAX. STEP AT OUT SWING DOORS (R311.3.1)
11 BATHTUB - FREE-STANDING, AS SELECTED (VERIFY LOC'N. OF FIXTURES W/. OWNER)
12 DRAIN LINE - IN WALL/FROM DECK/ROOF ABV. PROVIDE DRAIN SWEEP(ELBOW JOINT) PER CIVIL DWG'S., PRIOR TO POURING
SLAB. VERIFY LOC'N. W/. SITE DRAINAGE & COORD. W/. CIVIL
13 EXTERIOR GLASS GUARDRAIL - TEMPERED & LAMINATED - MIN. 42" HIGH - 4" MAX. SPHERE OPENING, REF. DTL. 4/AD-1
NO. REVISION DATE
1/4" = 1'-0"2 SECOND LEVEL FLOOR PLAN
PA2022-0187
ROOM TAGROOM NAME
1
A-5.0
1 1
?
1
1
A-4.0
1
1 1
1
ELEVATION / SECTION INDICATOR
AD-1.0
1 CALL-OUT TAG
10.00'SPOT ELEVATION
KEYNOTE TAG
REVISION TAG
DOOR / WINDOW / WINDOW WALL TAG
FIRE RATED CEILING ASS'Y -REF. DTLS. 7/AD-1.0
1-HR RATED INT CONDITION -REF. DTLS. 7/AD-1.0
1-HR RATED EXT CONDITION -REF. DTLS. 7/AD-1.0
STRUCTURAL STEEL COLUMN PER STRUCT., REF. STRUTC.
DWGS, -PAINT AND SEAL AS REQUIRED –ARCH. TO APPV.
COLOR FOR EXPOSED STEEL COLUMNS
STRUCTURAL WOOD POST/COLUMN COLUMN -PER STRUCT., REF. STRUTC. DWGS, -
PAINT, STAIN AND SEAL AS REQUIRED –ARCH. TO APPV. PAINT COLOR FOR EXPOSED
WOOD POST/COLUMN, IF TO BE STAINED PROVIDE STAINED SAMPLE FOR ARCH,
APPROVAL
DOORS -AS SPECIFIED, SEE WINDOW SCHEDULE AND GENERAL NOTES ON SHEET A-7.0 -
SHGC & U-FCTOR PER T-24 ENERGY REPORT – SEE SHEET AD-2.0 FOR JAMB, HEAD AND
THRESHOLD DETAILS, PROVIDE FLASHING AND WATERPROOFING AT DOOR OPENING PER
THE DOOR MFGR. INSTRUCTION AND/OR FLASHING MFGR. INSTRUCTION PER SECTIONS
R609.1 & R703.4 OF CRC
WINDOW -AS SPECIFIED, SEE WINDOW SCHEDULE AND GENERAL NOTES ON
SHEET A-7.0 -SHGC & U-FCTOR PER T-24 ENERGY REPORT – SEE SHEET
AD-2.0 FOR JAMB, HEAD AND SILL DETAILS, PROVIDE FLASHING AND
WATERPROOFING AT WINDOW OPENING PER THE WINDOW MFGR.
INSTRUCTION AND/OR FLASHING MFGR. INSTRUCTION PER SECTIONS R609.1
& R703.4 OF CRC
KITCHEN RANGE W/. EXHAUST HOOD -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –
PROVIDE POWER AND GAS AS REQUIRED -30”MIN. VERTICAL CLEARANCE TO ANY
COMBUSTIBLE MATERIAL ABV. COOKING TOP (CMC 920.3.2) –EXHAUST HOOD TO HAVE
EXHAUST RATE OF MIN. 100 CFM AND VENT TO OUTDOOR , HOOD DUCTS TO BE OF
METAL WITH SMOOTH INTERIOR FINISH PER SECTION 504.3 OF CMC
KITCHEN/BAR SINK -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –SINK TO COMPLY
W/. REQUIREMENT OF SECTION 420.0 OF CPC AND HAVE A MAX FLOW RATE OF 1.8 GPM
@ 60 PSI PER SECTION 4.303.1 OF CALGREEN –TRAP AND VENT FOR ISLAND SINK AND
SIMILAR EQUIPMENT SHALL BE PER SECTION 909.0 OF CPC
VANITY SINK -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –
LAVATORY TO HAVE 24”MIN. CLEAR SPACE IN FRONT OF IT.(CPC 402.5)
W/. MAXIMUM FLOW RATE OF 1.2 GPM @ 60 PSI AND MIN. FLOW RATE OF
0.8 GPM @ 20 PSI PER SECTION 4.303.1 OF CALGREEN
WASHER (W) / DRYER (D) / STACKED (W/D)-AS SELECTED PER I.D., VERIFY W/. I.D. &
OWNER –PROVIDE POWER , GAS, WATER SUPPLY & DRAINAGE AS REQUIRED -THE
CLOTHES DRYERS VENT SHALL BE OF A RIGID METALLIC MATERIAL AND HAVE A
BACKDRAFT DAMPER (CMC 504.4) AND SHALL NOT EXCEED 14-FEET IN OVERALL LENGTH
WITH MAX. OF TWO (2) 90-DEGREE ELBOW, SUBTRACT 2-FEET FOR EACH ADDITIONAL 90-
DEGREE ELBOW. SEE WASHER & DRYER NOTES, REF. T-1.1.
REFRIGERATOR (REF) / FREEZER (FRZ) -AS SELECTED PER I.D., VERIFY W/. I.D. &
OWNER –PROVIDE POWER AND WATER SUPPLY AS REQUIRED
BUILT-IN APPLIANCE / DISHWASHER (DW) / TRASH COMPACTOR (TR)-AS SELECTED PER
I.D., VERIFY W/. I.D. & OWNER –PROVIDE POWER , WATER SUPPLY & DRAINAGE PIPE AS
REQUIRED
TOILET -WATER CLOSET SHALL BE IN COMPLIANCE OF SECTION 411.0 OF CPC AND HAS
MAX EFFECTIVE FLUSH RATE OF 1.28 GAL. PER FLUSH (CPC 411.2). WATER CLOSETS
CLR. TO BE 24”IN FRONT AND 15”FROM ITS CENTER TO ANY SIDE WALL OR
OBSTRUCTION. (CPC 402.5 & CRC R307) –REF. CALGREEN NOTES ON T SHTS. FOR MAX
FLOW RATE
CASEWORK, TALL CABINET -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER
CASEWORK, BASE CABINET W/. COUNTERTOP -AS SELECTED PER I.D., VERIFY W/. I.D. &
OWNER
CASEWORK, UPPER CABINET/SHELVES -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER
BUILT-IN CLOSET -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER
FIREPLACE -FACTORY-BUILT DIRECT VENT GAS FIREPLACE W/. SEALED COMBUSTION
(CALGREEN 4.503) -FACTORY-BUILT FIREPLACES, CHIMNEYS AND ALL OF THEIR
COMPONENTS SHALL BE LISTED AND INSTALLED IN ACCORDANCE WITH THEIR LISTING
AND MANUFACTURER'S INSTALLATION INSTRUCTIONS. (CRC R1004.1)
ELEVATOR -PRIVATE RESIDENCE ELEVATOR IN COMPLIANCE W/. ASME A17.1/CSA B44
AS SELECTED PER PLANS, VERIFY W/. OWNER –PROVIDE POWER AS REQ'D. (CRC 321.1)
A/C CONDENSER / HEAT PUMP -TO BE IN COMPLIANCE OF SECTION 307.3 OF CMC AS
SELECTED, VERIFY W/. OWNER -SIZE TBD, SEE T-24 ENERGY REPORT FOR MORE INFO –
PROVIDE POWER AND SOUND DAMPENING PAD AS REQ’D. –INSTALL AND MAINTAIN
REQUIRED CLEARANCES PER MFGR. INSTRUCTION
FAU -PROVIDE GAS S.O., POWER, AND VENTING AS REQ'D. BY MFG'R. –INSTALL PER
MFGR. INSTRUCTION
ROOF/DECK DRAIN -PER CHAPTER 11 OF CPC -SIZE THE DRAIN AND PIPING PER TABLE
1103.1 AND 1103.2 OF CPC –ROOF DRAIN SHALL HAVE DOMED STRAINER (CPC 1102.2) –
REF. DETAIL 11/AD-1.0
OVERFLOW OR EMERGENCY DRAIN -PER CHAPTER 11 OF CPC -COPPER OR EQ., INSTALL
PER MFGR. INSTRUC., SLOPED TOWARD IN-WALL DRAIN INLETS –SLOPE AND SIZE PER
TABLE 1103.3 OF CPC –REF. DTL. 11/AD-1.0
UP
20R@7 1/2"STAIRS -MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE AN ILLUMINATION LEVEL OF NOT
LESS THAN 1 FOOT CANDLE AS MEASURED AT THE CENTER OF TREADS AND
LANDING WITH ARTIFICIAL LIGHTING (R303.7) -REF. DTL. 3/AD-1
A-4.0
1
2
A-5.0
2
A-5.0
A-4.02
A-4.0
4
A-4.0 3
4
A-5.0
4
A-5.0
1
A-5.0
1
A-5.0
3
A-5.0
3
A-5.0
1
A-5.1
1
A-5.1
2
A-5.1
2
A-5.1
3
A-5.1
3
A-5.1
4
A-5.1
4
A-5.1
1
2% SLOPE MIN.2% SLOPE MIN.2% SLOPE MIN.2% SLOPE MIN.2% SLOPE MIN.2% SLOPE MIN.
2% SLOPE MIN.2% SLOPE MIN.S.Y.S.B.3' - 0"S.Y.S.B.3' - 0"R.Y.S.B.
25' - 0"
PLANTING AREA
T.V.PLANTING AREAPLANTING AREA25
26
27DEN
WORKOUT DECK
COVERED CABANA
OUTDOOR DINING
FIREPIT
PWDR.
MECH
ELEV.
28
SPA
F.Y.S.B.
5' - 0"
1
2
2
3
4
4
5
5
5
5
6
7 R @ 0' -7 5/8"16
TYP.11"CLR.
3' - 6"
CLR.
3' - 6"CLR.3' - 6"CLR.
3' - 6"CLR.3' - 6"CLR.
3' - 6"
8PLANTING AREA9
T.V.
BBQ.
-
---
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
KEYNOTESB
ANNOTATION LEGENDA
BRANDON ARCHITECTS
2/16/2022
THIRD LEVEL FLOOR
PLANHEDGE RESIDENCEEDDIE AND DESIREE HEDGE
1400 W. BAY AVENUE
NEWPORT BEACH, CA 92661
DD
1400 W. BAY AVENUE
A-2.1
**0000-2021**
JEFF VAN VOORHIS
1 FRONT YARD SETBACK
2 SIDE YARD SETBACK
3 REAR YARD SETBACK
4 PROPERTY LINE
5 LINEAR DRAIN - SLOPE 2% MIN. - REF. DTL. 11/AD-1
6 STAIRS - MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS THAN 1 FOOT
CANDLE (CBC 1205.4) REF. DTL. 3/AD-1
7 INTERIOR GLASS GUARDRAIL - MIN. 42" HIGH - MATERIAL AS SELECTED, <4" MAX. SPHERE OPENING, REF. DTL. 4/AD-1
8 EXTERIOR GLASS GUARDRAIL - TEMPERED & LAMINATED - MIN. 42" HIGH - 4" MAX. SPHERE OPENING, REF. DTL. 4/AD-1
9 GUTTER - ALUMINUM W/. KYNAR FINISH, SHAPE AS SEL. - PROVIDE SHOP DWGS. TO ARCH.
NO. REVISION DATE
1/4" = 1'-0"1 THIRD LEVEL FLOOR PLAN
PA2022-0187
DN
DN
DN
DIMENSION NOTE:
ALL DIMENSIONS ARE TO FACE OF SHEATHING (EXT. WALLS) OR FACE OF STRUCTURE (F.O.S.) TYP. U.N.O. ROUNDED TO THE
NEAREST 1/8" AND INTERIOR PARTITIONS ARE DIMENSIONED FROM FACE OF STRUCTURE TO FACE OF STRUCTURE (F.O.S.) U.N.O. -
CONTACT ARCHITECT IN WRITING FOR ANY CLARIFICATION OF NOTED DIMENSIONS, DO NOT SCALE PLANS.
ROUGH FRAMING:
ALL EXTERIOR WALLS TO BE FRAMED W/. 2X6 STUD MIN. U.N.O.
USE 2X6 MINIMUM STUDS FOR PLUMBING WALLS
SECOND AND THIRD FLOOR PLYWOOD TO BE 1-1/8"
ENTIRE EXTERIOR TO BE SHEATHED WITH 1/2" PLYWOOD
DOORS AND WINDOWS WILL TYPICALLY BE RECESSED FROM EXTERIOR WALL PLANE. VERIFY ALL ROUGH OPENING DIMENSIONS
WITH DOOR AND WINDOW MFGR. ROUGH OPENING MAY NEED TO BE OVERSIZED TO ACCOUNT FOR ADDITIONAL FRAMING. SEE
SHT. AD-2.0 FOR TYP. RECESSED CONDITIONS.
GARAGE FLOOR:
GARAGE FLOOR SURFACES SHALL BE OF APPROVED NONCOMBUSTIBLE MATERIAL.THE AREA OF FLOOR USED FOR PARKING OF
AUTOMOBILES OR OTHER VEHICLES SHALL BE SLOPED TO FACILITATE THE MOVEMENT OF LIQUIDS TO A DRAIN OR TOWARD THE
MAIN VEHICLE ENTRY DOORWAY. (R309.1)
PLUMBING:
1. SUPPORT ALL WALL-HUNG FIXTURES WITH METAL SUPPORTING MEMBERS TO PREVENT ANY STRAIN TRANSMISSION TO THE
CONNECTIONS. FRAMING AFFIXED SUPPORTS FOR OFF-THE-FLOOR WATER CLOSETS WITH CONCEALED TANKS SHALL COMPLY
WITH ASME A112.6.2. SECURE FLUSH TANK AND SIMILAR APPURTENANCES WITH APPROVED NON-CORROSIVE SCREW OR BOLTS.
(CPC 402.5)
2. THE NET AREA OF THE SHOWER ENCLOSURE SHALL BE 1,024 SQ. INCHES (7.1 SQ. FT.) OR MORE IN THE CLEAR FLOOR AREA,
AND SHALL ALSO BE CAPABLE OF ENCOMPASSING A 30-INCH DIAMETER CIRCLE. (CPC 408.6)
3. THE WATER HEATER BURNER AND BURNER-IGNITION DEVICE TO BE AT LEAST 18-INCHES ABOVE THE FLOOR, IF LOCATED IN A
GARAGE AND IN ADJACENT SPACES THAT OPEN TO THE GARAGE. FOR WATER HEATER IN THE GARAGE OR OTHER AREAS SUBJECT
TO MECHANICAL DAMAGE PROVIDE A PROTECTIVE BARRIER OR ELEVATE THE APPLIANCE TO BE OUT OF THE NORMAL PATH OF
THE VEHICLE. (CPC 507.13)
4. ANCHOR OR STRAP THE WATER HEATER(S) TO RESIST HORIZ. DISPLACEMENT DUE TO THE EARTHQUAKE. STRAPPING SHOULD
BE AT THE UPPER AND LOWER ONE THIRD (1/3) POINTS OF THE APPLIANCE HEIGHT. MAINTAIN A MIN. 4-INCHES ABOVE THE
CONTROLS WITH STRAPPING AT LOWER POINT.
WOOD OR WOODBASED PRODUCTS NOTE:
WOOD OR WOODBASE PRODUCT SHALL BE OF A NATURAL DURABLE OR PRESERVATIVE-TREADED WOOD IN ACCORDANCE WITH
AWPA U1 FOR THE SPECIES, PRODUCT, PRESERVATIVE AND END USE IN THE FOLLOWING LOCATIONS:
1. WOOD JOISTS OR THE BOTTOM OF A WOOD STRUCTURAL FLOOR WHEN CLOSER THAN 18 INCHES (457 MM) OR WOOD GIRDERS
WHEN CLOSER THAN 12 INCHES (305 MM) TO THE EXPOSED GROUND IN CRAWL SPACES OR UNEXCAVATED AREA LOCATED
WITHIN THE PERIPHERY OF THE BUILDING FOUNDATION.
2. WOOD FRAMING MEMBERS THAT REST ON CONCRETE OR MASONRY EXTERIOR FOUNDATION WALLS AND ARE LESS THAN 8
INCHES (203 MM) FROM THE EXPOSED GROUND.
3. SILLS AND SLEEPERS ON A CONCRETE OR MASONRY SLAB THAT IS IN DIRECT CONTACT WITH THE GROUND UNLESS
SEPARATED FROM SUCH SLAB BY AN IMPERVIOUS MOISTURE BARRIER.
4. THE ENDS OF WOOD GIRDERS ENTERING EXTERIOR MASONRY OR CONCRETE WALLS HAVING CLEARANCES OF LESS THAN 1/2
INCH (12.7 MM) ON TOPS, SIDES AND ENDS.
5. WOOD SIDING, SHEATHING AND WALL FRAMING ON THE EXTERIOR OF A BUILDING HAVING A CLEARANCE OF LESS THAN 6
INCHES (152 MM) FROM THE GROUND OR LESS THAN 2 INCHES (51 MM) MEASURED VERTICALLY FROM CONCRETE STEPS,
PORCH SLABS, PATIO SLABS AND SIMILAR HORIZONTAL SURFACES EXPOSED TO THE WEATHER.
6. WOOD STRUCTURAL MEMBERS SUPPORTING MOISTURE-PERMEABLE FLOORS OR ROOFS THAT ARE EXPOSED TO THE
WEATHER, SUCH AS CONCRETE OR MASONRY SLABS, UNLESS SEPARATED FROM SUCH FLOORS OR ROOFS BY AN IMPERVIOUS
MOISTURE BARRIER.
7. WOOD FURRING STRIPS OR OTHER WOOD FRAMING MEMBERS ATTACHED DIRECTLY TO THE INTERIOR OF EXTERIOR MASONRY
WALLS OR CONCRETE WALLS BELOW GRADE EXCEPT WHERE AN APPROVED VAPOR RETARDER IS APPLIED BETWEEN THE WALL
AND THE FURRING STRIPS OR FRAMING MEMBERS.
*HERS VERIFICATION REQUIRED-REFERENCE T-24.1
ROOM TAGROOM NAME
1
1
1
1
10.00'SPOT ELEVATION
REVISION TAG
DOOR TAG
WINDOW WALL TAG
WINDOW TAG
STRUCTURAL STEEL COLUMN PER STRUCT., REF. STRUTC.
DWGS, -PAINT AND SEAL AS REQUIRED –ARCH. TO APPV.
COLOR FOR EXPOSED STEEL COLUMNS
STRUCTURAL WOOD POST/COLUMN COLUMN -PER STRUCT., REF. STRUTC. DWGS, -
PAINT, STAIN AND SEAL AS REQUIRED –ARCH. TO APPV. PAINT COLOR FOR EXPOSED
WOOD POST/COLUMN, IF TO BE STAINED PROVIDE STAINED SAMPLE FOR ARCH,
APPROVAL
KITCHEN RANGE W/. EXHAUST HOOD -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –
PROVIDE POWER AND GAS AS REQUIRED -30”MIN. VERTICAL CLEARANCE TO ANY
COMBUSTIBLE MATERIAL ABV. COOKING TOP (CMC 920.3.2) –EXHAUST HOOD TO HAVE
EXHAUST RATE OF MIN. 100 CFM AND VENT TO OUTDOOR , HOOD DUCTS TO BE OF
METAL WITH SMOOTH INTERIOR FINISH PER SECTION 504.3 OF CMC
KITCHEN/BAR SINK -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –SINK TO COMPLY
W/. REQUIREMENT OF SECTION 420.0 OF CPC AND HAVE A MAX FLOW RATE OF 1.8 GPM
@ 60 PSI PER SECTION 4.303.1 OF CALGREEN –TRAP AND VENT FOR ISLAND SINK AND
SIMILAR EQUIPMENT SHALL BE PER SECTION 909.0 OF CPC
VANITY SINK -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –
LAVATORY TO HAVE 24”MIN. CLEAR SPACE IN FRONT OF IT.(CPC 402.5)
W/. MAXIMUM FLOW RATE OF 1.2 GPM @ 60 PSI AND MIN. FLOW RATE OF
0.8 GPM @ 20 PSI PER SECTION 4.303.1 OF CALGREEN
WASHER (W) / DRYER (D) / STACKED (W/D)-AS SELECTED PER I.D., VERIFY W/. I.D. &
OWNER –PROVIDE POWER , GAS, WATER SUPPLY & DRAINAGE AS REQUIRED -THE
CLOTHES DRYERS VENT SHALL BE OF A RIGID METALLIC MATERIAL AND HAVE A
BACKDRAFT DAMPER (CMC 504.4) AND SHALL NOT EXCEED 14-FEET IN OVERALL LENGTH
WITH MAX. OF TWO (2) 90-DEGREE ELBOW, SUBTRACT 2-FEET FOR EACH ADDITIONAL 90-
DEGREE ELBOW. SEE WASHER & DRYER NOTES, REF. T-1.1.
TOILET -WATER CLOSET SHALL BE IN COMPLIANCE OF SECTION 411.0 OF CPC AND HAS
MAX EFFECTIVE FLUSH RATE OF 1.28 GAL. PER FLUSH (CPC 411.2). WATER CLOSETS
CLR. TO BE 24”IN FRONT AND 15”FROM ITS CENTER TO ANY SIDE WALL OR
OBSTRUCTION. (CPC 402.5 & CRC R307) –REF. CALGREEN NOTES ON T SHTS. FOR MAX
FLOW RATE
FIREPLACE -FACTORY-BUILT DIRECT VENT GAS FIREPLACE W/. SEALED COMBUSTION
(CALGREEN 4.503) -FACTORY-BUILT FIREPLACES, CHIMNEYS AND ALL OF THEIR
COMPONENTS SHALL BE LISTED AND INSTALLED IN ACCORDANCE WITH THEIR LISTING
AND MANUFACTURER'S INSTALLATION INSTRUCTIONS. (CRC R1004.1)
A/C CONDENSER / HEAT PUMP -TO BE IN COMPLIANCE OF SECTION 307.3 OF CPC AS
SELECTED, VERIFY W/. OWNER -SIZE TBD, SEE T-24 ENERGY REPORT FOR MORE INFO –
PROVIDE POWER AND SOUND DAMPENING PAD AS REQ’D. –INSTALL AND MAINTAIN
REQUIRED CLEARANCES PER MFGR. INSTRUCTION
FAU -PROVIDE GAS S.O., POWER, AND VENTING AS REQ'D. BY MFG'R. –INSTALL PER
MFGR. INSTRUCTION
RECESSED MAIN SERVICE PANEL -400 AMP MAX. (MAINTAIN 36" CLEAR FROM FACE
OF PANEL TO ANY OBSTRUCTION) –GC TO COORDINATE W/. UTILITY COMPANY
ROOF/DECK DRAIN -PER CHAPTER 11 OF CPC -SIZE THE DRAIN AND PIPING PER TABLE
1103.1 AND 1103.2 OF CPC –ROOF DRAIN SHALL HAVE DOMED STRAINER (CPC 1102.2) –
REF. DETAIL 11/AD-1.0
OVERFLOW OR EMERGENCY DRAIN -PER CHAPTER 11 OF CPC -COPPER OR EQ., INSTALL
PER MFGR. INSTRUC., SLOPED TOWARD IN-WALL DRAIN INLETS –SLOPE AND SIZE PER
TABLE 1103.3 OF CPC –REF. DTL. 11/AD-1.0
2X4 STUD WALL
2X6 STUD WALL
2X8 STUD WALL
2X10 STUD WALL
EXT. POCKET DOOR WALL - TYP. 2X6 EXT. FRMG. AND 2X4 INTERIOR FRAMING W/.
DOUBLE TOP PLATE AND SINGLE SILL PLATE U.N.O., MIN. AIR SPACE/DOOR POCKET
TO BE VERIFIED W/. DOOR MFGR. - STUDS MIN. SPACING PER STRUCT. AND EXT.
FINISH MFGR. INSTRUCTION AND/OR LISTING –SEE EXT. WALL DETAILS AND STRUCT.
DWGS
CONCRETE WALL -12”REINFORCED CAST IN PLACE CONCRETE WALL TYP. U.N.O. PER
STRUCT., REF. STRCUTC. DWGS. –FOR BASEMENT/RETAINING CONCRETE WALL
PROVIDE WATERPROOFING OR DAMPPROOFING AND DRAINAGE AS REQUIRED PER
SECTION R406.1 & R406.2, REF. SOILS REPORT,WATERPROOFING & DAMPROOFING
NOTES ON SHEET T-1.1 –EXPOSED SURFACES TO HAVE TROWELED SMOOTH FINISH
WITH A LIGHT GRAY COLOR, PROVIDE SAMPLE FOR ARCH. APPROVAL
SLAB/FRAMING DEPRESSION -SEE STRUCT. DWGS. FOR THE RECESSION DETAILS -
FOR RECESSION SPECIFIC TO EQUIPMENT OR ASSEMBLY VERIFY THE REQUIRED
RECESSION W/. MFGR. OR FABRICATOR –SHOWER RECESSION TO BE VERIFIED W/.
I.D.
SEE SHEET AD-2.0 FOR THE TYPICAL DEPRESSION OF DOORS AND WINDOWS, VERIFY
ALL DEPRESSIONS W/. MFGR.
STUDS MIN. SPACING PER STRUCT. AND EXT. FINISH MFGR.
INSTRUCTION AND/OR LISTING –SEE EXT. WALL DETAILS AND
STRUCT. DWGS
VERTICAL STORM DRAIN PIPE IN-WALL / OVERFLOW -MTL. PIPE PER
CHAPTER 11 OF CPC, SIZE PER TABLE 1103.1 (MIN. 2”DIA. PIPE & TYP. 3”DIA. PIPE) –
SEE CIVIL DWGS. FOR TERMINATION DTLS. ABV. OR BLW. GROUND. VERIFY ALL
TERMINATION POINTS, TYPE AND DETAILS W/. CIVIL PRIOR TO POURING THE CONCRETE
SLAB
OVERFLOW
DRAINLINE
A-4.0
1
2
A-5.0
2
A-5.0
A-4.02
A-4.0
4
A-4.0 3
4
A-5.0
4
A-5.0
1
A-5.0
1
A-5.0
3
A-5.0
3
A-5.0
1
A-5.1
1
A-5.1
2
A-5.1
2
A-5.1
3
A-5.1
3
A-5.1
4
A-5.1
4
A-5.1
79' - 6 1/8"
69' - 5 3/8"1' - 4 5/8"7' - 1 5/8"1' - 6 1/2"28' - 3 1/4"69' - 11 1/2"
12' - 5 1/8"8' - 3 3/8"10' - 10 1/4"5' - 2"5"12' - 8 3/8"14' - 8 1/8"5' - 5 1/4"28' - 11 3/8"2' - 5 5/8"18' - 0"2' - 7 1/8"5' - 4 1/4"6 3/8"16' - 11 3/4"10' - 5 1/8"52' - 1 1/4"
CLR.
20' - 1 1/4"CLR.22' - 0 3/4"DININGLOUNGE
GREAT ROOM
KITCHEN
PANTRY
PWDR.
FOYER
2-CAR GARAGE
STORAGE
C/C.
A-4.0
1
2
A-5.0
2
A-5.0
A-4.02
A-4.0
4
A-4.0 3
4
A-5.0
4
A-5.0
1
A-5.0
1
A-5.0
3
A-5.0
3
A-5.0
1
A-5.1
1
A-5.1
2
A-5.1
2
A-5.1
3
A-5.1
3
A-5.1
4
A-5.1
4
A-5.1
79' - 6 5/8"
11' - 2 3/8"10' - 4 7/8"15' - 6 3/4"25' - 3 7/8"13' - 8 7/8"3' - 3 7/8"
82' - 2 7/8"28' - 4 7/8"20' - 5 7/8"7' - 11"1' - 0"11' - 3 1/8"9"7' - 8 3/8"10' - 10 1/4"5' - 7"12' - 8 3/8"14' - 8 1/8"10' - 11 3/4"6' - 8 7/8"1' - 10 1/8"12' - 10 1/8"2' - 4 3/4"6' - 6 7/8"1' - 3 7/8"3' - 9 1/2"28' - 9"MECH.
BATH #2 BED #2
HALLWAY
BATH #3
BED #3
BED #4
BATH #4
PRIMARY W.I.C.
LAUNDRY
W/C.
PRIMARY BATH
PRIMARY BEDROOM
C/C.
ELEV.
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
BRANDON ARCHITECTS
ANNOTATION LEGEND
GENERAL NOTESA
B
2/16/2022
FIRST & SECOND
LEVEL DIMENSION
PLANSHEDGE RESIDENCEEDDIE AND DESIREE HEDGE
1400 W. BAY AVENUE
NEWPORT BEACH, CA 92661
DD
1400 W. BAY AVENUE
A-2.2
**0000-2021**
JEFF VAN VOORHIS
NO. REVISION DATE
1/4" = 1'-0"1 FIRST LEVEL DIMENSION PLAN
1/4" = 1'-0"2 SECOND LEVEL DIMENSION PLAN
PA2022-0187
DIMENSION NOTE:
ALL DIMENSIONS ARE TO FACE OF SHEATHING (EXT. WALLS) OR FACE OF STRUCTURE (F.O.S.) TYP. U.N.O. ROUNDED TO THE
NEAREST 1/8" AND INTERIOR PARTITIONS ARE DIMENSIONED FROM FACE OF STRUCTURE TO FACE OF STRUCTURE (F.O.S.) U.N.O. -
CONTACT ARCHITECT IN WRITING FOR ANY CLARIFICATION OF NOTED DIMENSIONS, DO NOT SCALE PLANS.
ROUGH FRAMING:
ALL EXTERIOR WALLS TO BE FRAMED W/. 2X6 STUD MIN. U.N.O.
USE 2X6 MINIMUM STUDS FOR PLUMBING WALLS
SECOND AND THIRD FLOOR PLYWOOD TO BE 1-1/8"
ENTIRE EXTERIOR TO BE SHEATHED WITH 1/2" PLYWOOD
DOORS AND WINDOWS WILL TYPICALLY BE RECESSED FROM EXTERIOR WALL PLANE. VERIFY ALL ROUGH OPENING DIMENSIONS
WITH DOOR AND WINDOW MFGR. ROUGH OPENING MAY NEED TO BE OVERSIZED TO ACCOUNT FOR ADDITIONAL FRAMING. SEE
SHT. AD-2.0 FOR TYP. RECESSED CONDITIONS.
GARAGE FLOOR:
GARAGE FLOOR SURFACES SHALL BE OF APPROVED NONCOMBUSTIBLE MATERIAL.THE AREA OF FLOOR USED FOR PARKING OF
AUTOMOBILES OR OTHER VEHICLES SHALL BE SLOPED TO FACILITATE THE MOVEMENT OF LIQUIDS TO A DRAIN OR TOWARD THE
MAIN VEHICLE ENTRY DOORWAY. (R309.1)
PLUMBING:
1. SUPPORT ALL WALL-HUNG FIXTURES WITH METAL SUPPORTING MEMBERS TO PREVENT ANY STRAIN TRANSMISSION TO THE
CONNECTIONS. FRAMING AFFIXED SUPPORTS FOR OFF-THE-FLOOR WATER CLOSETS WITH CONCEALED TANKS SHALL COMPLY
WITH ASME A112.6.2. SECURE FLUSH TANK AND SIMILAR APPURTENANCES WITH APPROVED NON-CORROSIVE SCREW OR BOLTS.
(CPC 402.5)
2. THE NET AREA OF THE SHOWER ENCLOSURE SHALL BE 1,024 SQ. INCHES (7.1 SQ. FT.) OR MORE IN THE CLEAR FLOOR AREA,
AND SHALL ALSO BE CAPABLE OF ENCOMPASSING A 30-INCH DIAMETER CIRCLE. (CPC 408.6)
3. THE WATER HEATER BURNER AND BURNER-IGNITION DEVICE TO BE AT LEAST 18-INCHES ABOVE THE FLOOR, IF LOCATED IN A
GARAGE AND IN ADJACENT SPACES THAT OPEN TO THE GARAGE. FOR WATER HEATER IN THE GARAGE OR OTHER AREAS SUBJECT
TO MECHANICAL DAMAGE PROVIDE A PROTECTIVE BARRIER OR ELEVATE THE APPLIANCE TO BE OUT OF THE NORMAL PATH OF
THE VEHICLE. (CPC 507.13)
4. ANCHOR OR STRAP THE WATER HEATER(S) TO RESIST HORIZ. DISPLACEMENT DUE TO THE EARTHQUAKE. STRAPPING SHOULD
BE AT THE UPPER AND LOWER ONE THIRD (1/3) POINTS OF THE APPLIANCE HEIGHT. MAINTAIN A MIN. 4-INCHES ABOVE THE
CONTROLS WITH STRAPPING AT LOWER POINT.
WOOD OR WOODBASED PRODUCTS NOTE:
WOOD OR WOODBASE PRODUCT SHALL BE OF A NATURAL DURABLE OR PRESERVATIVE-TREADED WOOD IN ACCORDANCE WITH
AWPA U1 FOR THE SPECIES, PRODUCT, PRESERVATIVE AND END USE IN THE FOLLOWING LOCATIONS:
1. WOOD JOISTS OR THE BOTTOM OF A WOOD STRUCTURAL FLOOR WHEN CLOSER THAN 18 INCHES (457 MM) OR WOOD GIRDERS
WHEN CLOSER THAN 12 INCHES (305 MM) TO THE EXPOSED GROUND IN CRAWL SPACES OR UNEXCAVATED AREA LOCATED
WITHIN THE PERIPHERY OF THE BUILDING FOUNDATION.
2. WOOD FRAMING MEMBERS THAT REST ON CONCRETE OR MASONRY EXTERIOR FOUNDATION WALLS AND ARE LESS THAN 8
INCHES (203 MM) FROM THE EXPOSED GROUND.
3. SILLS AND SLEEPERS ON A CONCRETE OR MASONRY SLAB THAT IS IN DIRECT CONTACT WITH THE GROUND UNLESS
SEPARATED FROM SUCH SLAB BY AN IMPERVIOUS MOISTURE BARRIER.
4. THE ENDS OF WOOD GIRDERS ENTERING EXTERIOR MASONRY OR CONCRETE WALLS HAVING CLEARANCES OF LESS THAN 1/2
INCH (12.7 MM) ON TOPS, SIDES AND ENDS.
5. WOOD SIDING, SHEATHING AND WALL FRAMING ON THE EXTERIOR OF A BUILDING HAVING A CLEARANCE OF LESS THAN 6
INCHES (152 MM) FROM THE GROUND OR LESS THAN 2 INCHES (51 MM) MEASURED VERTICALLY FROM CONCRETE STEPS,
PORCH SLABS, PATIO SLABS AND SIMILAR HORIZONTAL SURFACES EXPOSED TO THE WEATHER.
6. WOOD STRUCTURAL MEMBERS SUPPORTING MOISTURE-PERMEABLE FLOORS OR ROOFS THAT ARE EXPOSED TO THE
WEATHER, SUCH AS CONCRETE OR MASONRY SLABS, UNLESS SEPARATED FROM SUCH FLOORS OR ROOFS BY AN IMPERVIOUS
MOISTURE BARRIER.
7. WOOD FURRING STRIPS OR OTHER WOOD FRAMING MEMBERS ATTACHED DIRECTLY TO THE INTERIOR OF EXTERIOR MASONRY
WALLS OR CONCRETE WALLS BELOW GRADE EXCEPT WHERE AN APPROVED VAPOR RETARDER IS APPLIED BETWEEN THE WALL
AND THE FURRING STRIPS OR FRAMING MEMBERS.
*HERS VERIFICATION REQUIRED-REFERENCE T-24.1
ROOM TAGROOM NAME
1
1
1
1
10.00'SPOT ELEVATION
REVISION TAG
DOOR TAG
WINDOW WALL TAG
WINDOW TAG
STRUCTURAL STEEL COLUMN PER STRUCT., REF. STRUTC.
DWGS, -PAINT AND SEAL AS REQUIRED –ARCH. TO APPV.
COLOR FOR EXPOSED STEEL COLUMNS
STRUCTURAL WOOD POST/COLUMN COLUMN -PER STRUCT., REF. STRUTC. DWGS, -
PAINT, STAIN AND SEAL AS REQUIRED –ARCH. TO APPV. PAINT COLOR FOR EXPOSED
WOOD POST/COLUMN, IF TO BE STAINED PROVIDE STAINED SAMPLE FOR ARCH,
APPROVAL
KITCHEN RANGE W/. EXHAUST HOOD -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –
PROVIDE POWER AND GAS AS REQUIRED -30”MIN. VERTICAL CLEARANCE TO ANY
COMBUSTIBLE MATERIAL ABV. COOKING TOP (CMC 920.3.2) –EXHAUST HOOD TO HAVE
EXHAUST RATE OF MIN. 100 CFM AND VENT TO OUTDOOR , HOOD DUCTS TO BE OF
METAL WITH SMOOTH INTERIOR FINISH PER SECTION 504.3 OF CMC
KITCHEN/BAR SINK -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –SINK TO COMPLY
W/. REQUIREMENT OF SECTION 420.0 OF CPC AND HAVE A MAX FLOW RATE OF 1.8 GPM
@ 60 PSI PER SECTION 4.303.1 OF CALGREEN –TRAP AND VENT FOR ISLAND SINK AND
SIMILAR EQUIPMENT SHALL BE PER SECTION 909.0 OF CPC
VANITY SINK -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –
LAVATORY TO HAVE 24”MIN. CLEAR SPACE IN FRONT OF IT.(CPC 402.5)
W/. MAXIMUM FLOW RATE OF 1.2 GPM @ 60 PSI AND MIN. FLOW RATE OF
0.8 GPM @ 20 PSI PER SECTION 4.303.1 OF CALGREEN
WASHER (W) / DRYER (D) / STACKED (W/D)-AS SELECTED PER I.D., VERIFY W/. I.D. &
OWNER –PROVIDE POWER , GAS, WATER SUPPLY & DRAINAGE AS REQUIRED -THE
CLOTHES DRYERS VENT SHALL BE OF A RIGID METALLIC MATERIAL AND HAVE A
BACKDRAFT DAMPER (CMC 504.4) AND SHALL NOT EXCEED 14-FEET IN OVERALL LENGTH
WITH MAX. OF TWO (2) 90-DEGREE ELBOW, SUBTRACT 2-FEET FOR EACH ADDITIONAL 90-
DEGREE ELBOW. SEE WASHER & DRYER NOTES, REF. T-1.1.
TOILET -WATER CLOSET SHALL BE IN COMPLIANCE OF SECTION 411.0 OF CPC AND HAS
MAX EFFECTIVE FLUSH RATE OF 1.28 GAL. PER FLUSH (CPC 411.2). WATER CLOSETS
CLR. TO BE 24”IN FRONT AND 15”FROM ITS CENTER TO ANY SIDE WALL OR
OBSTRUCTION. (CPC 402.5 & CRC R307) –REF. CALGREEN NOTES ON T SHTS. FOR MAX
FLOW RATE
FIREPLACE -FACTORY-BUILT DIRECT VENT GAS FIREPLACE W/. SEALED COMBUSTION
(CALGREEN 4.503) -FACTORY-BUILT FIREPLACES, CHIMNEYS AND ALL OF THEIR
COMPONENTS SHALL BE LISTED AND INSTALLED IN ACCORDANCE WITH THEIR LISTING
AND MANUFACTURER'S INSTALLATION INSTRUCTIONS. (CRC R1004.1)
A/C CONDENSER / HEAT PUMP -TO BE IN COMPLIANCE OF SECTION 307.3 OF CPC AS
SELECTED, VERIFY W/. OWNER -SIZE TBD, SEE T-24 ENERGY REPORT FOR MORE INFO –
PROVIDE POWER AND SOUND DAMPENING PAD AS REQ’D. –INSTALL AND MAINTAIN
REQUIRED CLEARANCES PER MFGR. INSTRUCTION
FAU -PROVIDE GAS S.O., POWER, AND VENTING AS REQ'D. BY MFG'R. –INSTALL PER
MFGR. INSTRUCTION
RECESSED MAIN SERVICE PANEL -400 AMP MAX. (MAINTAIN 36" CLEAR FROM FACE
OF PANEL TO ANY OBSTRUCTION) –GC TO COORDINATE W/. UTILITY COMPANY
ROOF/DECK DRAIN -PER CHAPTER 11 OF CPC -SIZE THE DRAIN AND PIPING PER TABLE
1103.1 AND 1103.2 OF CPC –ROOF DRAIN SHALL HAVE DOMED STRAINER (CPC 1102.2) –
REF. DETAIL 11/AD-1.0
OVERFLOW OR EMERGENCY DRAIN -PER CHAPTER 11 OF CPC -COPPER OR EQ., INSTALL
PER MFGR. INSTRUC., SLOPED TOWARD IN-WALL DRAIN INLETS –SLOPE AND SIZE PER
TABLE 1103.3 OF CPC –REF. DTL. 11/AD-1.0
2X4 STUD WALL
2X6 STUD WALL
2X8 STUD WALL
2X10 STUD WALL
EXT. POCKET DOOR WALL - TYP. 2X6 EXT. FRMG. AND 2X4 INTERIOR FRAMING W/.
DOUBLE TOP PLATE AND SINGLE SILL PLATE U.N.O., MIN. AIR SPACE/DOOR POCKET
TO BE VERIFIED W/. DOOR MFGR. - STUDS MIN. SPACING PER STRUCT. AND EXT.
FINISH MFGR. INSTRUCTION AND/OR LISTING –SEE EXT. WALL DETAILS AND STRUCT.
DWGS
CONCRETE WALL -12”REINFORCED CAST IN PLACE CONCRETE WALL TYP. U.N.O. PER
STRUCT., REF. STRCUTC. DWGS. –FOR BASEMENT/RETAINING CONCRETE WALL
PROVIDE WATERPROOFING OR DAMPPROOFING AND DRAINAGE AS REQUIRED PER
SECTION R406.1 & R406.2, REF. SOILS REPORT,WATERPROOFING & DAMPROOFING
NOTES ON SHEET T-1.1 –EXPOSED SURFACES TO HAVE TROWELED SMOOTH FINISH
WITH A LIGHT GRAY COLOR, PROVIDE SAMPLE FOR ARCH. APPROVAL
SLAB/FRAMING DEPRESSION -SEE STRUCT. DWGS. FOR THE RECESSION DETAILS -
FOR RECESSION SPECIFIC TO EQUIPMENT OR ASSEMBLY VERIFY THE REQUIRED
RECESSION W/. MFGR. OR FABRICATOR –SHOWER RECESSION TO BE VERIFIED W/.
I.D.
SEE SHEET AD-2.0 FOR THE TYPICAL DEPRESSION OF DOORS AND WINDOWS, VERIFY
ALL DEPRESSIONS W/. MFGR.
STUDS MIN. SPACING PER STRUCT. AND EXT. FINISH MFGR.
INSTRUCTION AND/OR LISTING –SEE EXT. WALL DETAILS AND
STRUCT. DWGS
VERTICAL STORM DRAIN PIPE IN-WALL / OVERFLOW -MTL. PIPE PER
CHAPTER 11 OF CPC, SIZE PER TABLE 1103.1 (MIN. 2”DIA. PIPE & TYP. 3”DIA. PIPE) –
SEE CIVIL DWGS. FOR TERMINATION DTLS. ABV. OR BLW. GROUND. VERIFY ALL
TERMINATION POINTS, TYPE AND DETAILS W/. CIVIL PRIOR TO POURING THE CONCRETE
SLAB
OVERFLOW
DRAINLINE
A-4.0
1
2
A-5.0
2
A-5.0
A-4.02
A-4.0
4
A-4.0 3
4
A-5.0
4
A-5.0
1
A-5.0
1
A-5.0
3
A-5.0
3
A-5.0
1
A-5.1
1
A-5.1
2
A-5.1
2
A-5.1
3
A-5.1
3
A-5.1
4
A-5.1
4
A-5.1
2% SLOPE MIN.2% SLOPE MIN.2% SLOPE MIN.2% SLOPE MIN.2% SLOPE MIN.2% SLOPE MIN.2% SLOPE MIN.2% SLOPE MIN.
DEN
WORKOUT DECK
COVERED CABANA
OUTDOOR DINING
FIREPIT
PWDR.
MECH
ELEV.
SPA
82' - 9 5/8"29' - 6"21' - 3"10' - 11 1/4"48' - 0 3/8"2' - 7"
2' - 6"13' - 2 1/2"5' - 6 1/2"7 1/8"9' - 9"7 1/8"5' - 6 1/2"12' - 8 3/8"32' - 4 1/2"2' - 0 1/2"20' - 3 1/2"6' - 8 1/8"6"82' - 9 5/8"
7' - 2 1/2"7' - 2 1/8"1' - 9 7/8"13' - 11 1/2"6' - 5 3/8"13' - 9 3/4"10' - 9 3/8"19' - 0 5/8"2' - 6 1/2"29' - 1"2' - 4"24' - 7 1/2"2' - 1 5/8"DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
BRANDON ARCHITECTS
ANNOTATION LEGEND
GENERAL NOTESA
B
2/16/2022
THIRD LEVEL
DIMENSION PLANHEDGE RESIDENCEEDDIE AND DESIREE HEDGE
1400 W. BAY AVENUE
NEWPORT BEACH, CA 92661
DD
1400 W. BAY AVENUE
A-2.3
**0000-2021**
JEFF VAN VOORHIS
NO. REVISION DATE
1/4" = 1'-0"1 THIRD LEVEL DIMENSION PLAN
PA2022-0187
DIMENSION NOTE:
ALL DIMS. ARE TO FACE OF STUD (F.O.S.) OR FACE OF SHT'G. (F.O.S.) TYP. U.N.O. EAVE DIMS. ARE FROM FACE OF SHT'G. TO FACE
OF FINISH FASCIA
ENCLOSED ATTIC AND ENCLOSED RAFTER SPACES VENTING NOTES:
1. ENCLOSED ATTIC AND ENCLOSED RAFTER SPACES SHALL HAVE CROSS VENTILATION BY VENTILATION OPENING PROTECTED
AGAINST THE ENTRANCE OF RAIN OR SNOW UNLESS THEY MEET THE REQUIREMENT OF SECTION R806.5 FOR UNVENTED ATTIC
AND UNVENTED ENCLOSED RAFTER ASSEMBLIES. VENTILATION OPENING SHALL HAVE THE LEAST DIMENSION OF 1/16”MIN. AND
1/4”MAX OTHERWISE THE OPENING SHALL HAVE THE CORROSION-RESISTANT WIRE CLOTH SCREENING, HARDWARE CLOTH,
PERFORATED VINYL OR SIMILAR MATERIAL WITH OPENINGS HAVE A LEAST DIMENSION OF 1/16”MIN. AND 1/4”MAX. OPENING IN
ROOF FRAMING MEMBERS SHALL BE PER THE REQUIREMENT OF SECTION R802.7. REQUIRED VENTILATION OPENINGS SHALL
OPEN DIRECTLY TO THE OUTSIDE AIR AND SHALL BE PROTECTED TO PREVENT THE ENTRY OF BIRDS, RODENTS, SNAKES AND
OTHER SIMILAR CREATURES. (R806.1)
2. THE MINIMUM NET FREE VENTILATING AREA SHOULD BE 1/150 OF THE AREA OF THE VENTED SPACE, EXCEPT FOR THE PROJECT
LOCATED IN CLIMATE ZONE 14 OR 16 WITH A CLASS I OR II VAPOR RETARDER AT THE WARM-IN-WINTER SIDE OF THE CEILING
AND WHERE MIN. 40% AND MAX 50% OF THE REQUIRED VENTILATION PROVIDED IN THE UPPER PORTION OF THE ATTIC OR
RAFTER SPACE PER SECTION R806.2 THEN THE MINIMUM NET FREE VENTILATING AREA CAN BE 1/300 OF THE VENTED SPACE.
(R802.2)
3. PROVIDE 1”SPACE BETWEEN THE INSULATION AND THE ROOF SHEATHING WHERE EAVE OR CORNICE VENTS PROVIDE
BLOCKING, BRIDGING AND INSULATION SHALL NOT BLOCK THE FREE FLOW OF AIR. (R806.3)
4. INSTALL VENTILATOR PER MANUFACTURER INSTRUCTION. INSTALL VENTILATOR IN ROOF PER SECTION R903 AND VENTILATOR
IN WALL ASSEMBLIES PER SECTION R703.1.
5. FOR THE ATTIC WITH VERTICAL HEIGHT GREATER THAN OR EQUAL TO 30”(VERTICAL HEIGHT MEASURED FROM THE TOP OF
CEILING JOIST TO THE BOTTOM OF THE ROOF RAFTERS) WITHIN 30S.F. MIN. PROVIDE THE OPENING WITH ROUGH-FRAMED
OPENING OF NOT LESS THAN 22”X30”WHICH SHOULD BE LOCATED IN HALLWAY OR OTHER LOCATION WITH READY ACCESS. IF
THE ACCESS LOCATED IN THE WALL THEN THE WIDTH SHOULD BE 22”AND HEIGHT SHOULD BE 30”MIN. IF LOCATED IN CEILING
THEN THE MIN. UNOBSTRUCTED HEADROOM IN THE ATTIC SHOULD BE 30”FROM THE BOTTOM OF CEILING JOIST AT SOME POINT.
ROOF DRAINAGE:
IF THE PROJECT LOCATED IN THE AREA WITH EXPANSIVE OR COLLAPSIBLE SOILS, WATER RUNOFF FROM ROOFS OF ALL
DWELLINGS SHALL BE DISCHARGED TO THE GROUND SURFACE NOT LESS THAN 5 FEET FROM FOUNDATION WALLS OR TO AN
APPROVED DRAINAGE SYSTEM. (R801.3) -REF.CIVIL DWGS FOR STORM WATER MANAGMENT AND SYSTEM.
WEATHER PROTECTION:
1. ROOF DECKS SHALL BE COVERED WITH APPROVED ROOF COVERINGS SECURED TO THE BUILDING OR STRUCTURE IN
ACCORDANCE WITH THE CHAPTER 9 OF THE CURRENT CRC. ROOF ASSEMBLIES SHALL BE DESIGNED AND INSTALLED IN
ACCORDANCE WITH THE CHAPTER 9 OF CRC AND THE APPROVED MANUFACTURER’S INSTRUCTIONS SUCH THAT THE ROOF
ASSEMBLY SHALL SERVE TO PROTECT THE BUILDING OR STRUCTURE. (R903.1)
2. PROVIDE AND INSTALL FLASHING TO PREVENT ENTRY OF MOISTURE TO WALL AND ROOF ASSEMBLIES THRU THE JOINTS IN
COPINGS, PERMEABLE MATERIAL, AND AT INTERSECTION WITH PARAPET WALLS AND OTHER PENETRATION THRU ROOF. (R903.2)
3. FLASHINGS SHALL BE INSTALLED AT WALL AND ROOF INTERSECTIONS, WHEREVER THERE IS A CHANGE IN ROOF SLOPE OR
DIRECTION AND AROUND ROOF OPENINGS. A FLASHING SHALL BE INSTALLED TO DIVERT THE WATER AWAY FROM WHERE THE
EAVE OF A SLOPED ROOF INTERSECTS A VERTICAL SIDEWALL. WHERE FLASHING IS OF METAL, THE METAL SHALL BE CORROSION
RESISTANT WITH A THICKNESS OF NOT LESS THAN 0.019 INCH (0.5 MM) (NO. 26 GALVANIZED SHEET). (R903.2.1)
4. A CRICKET OR SADDLE SHALL BE INSTALLED ON THE RIDGE SIDE OF ANY CHIMNEY OR PENETRATION MORE THAN 30 INCHES
(762 MM) WIDE AS MEASURED PERPENDICULAR TO THE SLOPE. CRICKET OR SADDLE COVERINGS SHALL BE SHEET METAL OR OF
THE SAME MATERIAL AS THE ROOF COVERING. EXCEPT FOR UNIT SKYLIGHTS INSTALLED IN ACCORDANCE WITH HYPERLINK
"HTTPS://CODES.ICCSAFE.ORG/LOOKUP/CRC2019P1_PT03_CH03_SECR308.6" SECTION R308.6 AND FLASHED IN ACCORDANCE
WITH THE MANUFACTURER’S INSTRUCTIONS SHALL BE PERMITTED TO BE INSTALLED WITHOUT A CRICKET OR SADDLE. (R903.2)
5. PARAPET WALLS SHALL BE PROPERLY COPED WITH NONCOMBUSTIBLE, WEATHERPROOF MATERIALS OF A WIDTH NOT LESS
THAN THE THICKNESS OF THE PARAPET WALL. (R903.3)
6. UNLESS ROOFS ARE SLOPED TO DRAIN OVER ROOF EDGES, ROOF DRAINS SHALL BE INSTALLED AT EACH LOW POINT OF THE
ROOF. IF WATER CAN BE ENTRAPPED WITHIN THE ROOF AREA THEN SECONDARY EMERGENCY OVERFLOW ROOF DRAINS OR
SCUPPERS SHALL BE PROVIDED PER SECTION R903.4.1. (R903.4)
MISC. NOTES:
1. INSTALL ROOF PER ROOFING MFG'R. SPECS & INSTALLATION GUIDELINE
2. ARCH. TO APPV. SIZE, COLOR & PROFILE OF EAVE & RAKE COMPONENTS. G.C. TO PROVIDE MOCK-UPS.
3. UNVENTED ENCLOSED RAFTER ASSEMBLY: NO INTERIOR CLASS I VAPOR RETARDER SHALL BE INSTALLED ON THE CEILING SIDE
(ATTIC FLOOR) OF THE UNVENTED ATTIC ASSEMBLY OR ON THE CEILING SIDE OF THE UNVENTED ENCLOSED ROOF FRAMING
ASSEMBLY.
4. REF. WOOD OR WOODBASE PRODUCT NOTES ON FLOOR PLANS
2
A-5.0
2
A-5.0
4
A-5.0
4
A-5.0
1
A-5.0
1
A-5.0
3
A-5.0
3
A-5.0
1
A-5.1
1
A-5.1
2
A-5.1
2
A-5.1
3
A-5.1
3
A-5.1
4
A-5.1
4
A-5.1
PLANTER AREAPLANTER AREAPLANTER AREA PLANTER AREA2% SLOPE MIN.2% SLOPE MIN.2% SLOPE MIN.2% SLOPE MIN.
2% SLOPE MIN.2% SLOPE MIN.S.Y.S.B.3' - 0"S.Y.S.B.3' - 0"F.Y.S.B.
5' - 0"
R.Y.S.B.
25' - 0"3:123:123:123:123:123:123:123:123:121:123:123:120.24:12
1
1
1
1
1F.O.F.2' - 7"F.O.F.3' - 1"F.O.F.3' - 1"F.O.F.2' - 6 1/8"F.O.F.
4' - 6 3/8"
F.O.F.
22' - 6 3/4"
38.00'38.00'
38.00'
37.38'
38.00'
2
3
3
4
5
5
6
-
---
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
GENERAL NOTESA
B KEYNOTES
BRANDON ARCHITECTS
2/16/2022
ROOF PLANHEDGE RESIDENCEEDDIE AND DESIREE HEDGE
1400 W. BAY AVENUE
NEWPORT BEACH, CA 92661
DD
1400 W. BAY AVENUE
A-3.0
**0000-2021**
JEFF VAN VOORHIS
1 STANDING SEAM METAL ROOFING - REF. MAT. SCHEDULE SHT. A-4.0
2 GUTTER - ALUMINUM W/. KYNAR FINISH, SHAPE AS SEL. - PROVIDE SHOP DWGS. TO ARCH.
3 PROPERTY LINE
4 FRONT YARD SETBACK
5 SIDE YARD SETBACK
6 REAR YARD SETBACK
1/4" = 1'-0"1 ARCHITECTURAL ROOF PLAN
NO. REVISION DATE
PA2022-0187
FIRST LEVEL F.F.9.13'FIRST LEVEL F.F.9.13'SECOND LEVEL F.F.18.89'ROOF PLATE35.76'ROOF PLATE35.76'SECOND LEVEL FLOOR PLATE17.68'2A-5.0MAX. HT.38.00'MAX. HT.38.00'MAX. FLAT33.00'MAX. FLAT33.00'GRADE PLANE9.00'FIRST LEVEL T.O.S.9.00'FIRST LEVEL T.O.S.9.00'SECOND LEVEL T.O.S.18.76'24' - 0"29' - 0"ROOF DECK F.F.29.46'ROOF DECK T.O.S.29.33'ROOF DECK PLATE28.25'MASTER LEVEL F.F.19.83'MASTER LEVEL PLATE18.63'MASTER LEVEL T.O.S.19.71'THIRD LEVEL F.F.29.04'THIRD LEVEL T.O.S.28.92'THIRD LEVEL PLATE27.83'GARAGE T.O.C.8.00'3A-5.02A-5.13A-5.19' - 7 1/2"1' - 1"8' - 6 1/2"1' - 1"10' - 8 1/2"9' - 7 1/2"28' - 10 1/2"1' - 0"8' - 8 1/8"1' - 1"9' - 0 7/8"1' - 1"6' - 10 1/8"9' - 9 1/8"10' - 1 7/8"38.00'33.04'32.54'32.54'32.37'29.46'29.46'19.83'21543481232HD. HT.8' - 0"HD. HT.8' - 0"SILL HT.3' - 6"HD. HT.7' - 6"SILL HT. 3' - 6"HD. HT.8' - 0"HD. HT.8' - 11 3/8"HD. HT.8' - 0"HD. HT.8' - 0"ABV. F.F.42" MIN.4516ABV. F.F.42" MIN.24' - 0"29' - 0"WINDOWS & DOORS:AUTHORIZED DEALER (PRODUCTS LISTED BELOW)SUPPLIER:ASSOCIATED BUILDING SUPPLYADDRESS:STONE MILL DESIGN CENTER 2915 RED HILL AVE., SUITE F104, COSTA MESA, CA 92626CONTACT:JOE YOUNANPHONE:949-872-3319FAX:206-666-2150EMAIL:JYOUNAN@ABSSOCAL.COMWEB:WWW.ASSOCIATEDBUILDINGSUPPLY.COMALUMINUM CLAD WINDOWS & PATIO DOORSMANUFACTURER: JELD-WEN WINDOWS & DOORSPRODUCT:CUSTOM COLLECTIONADDRESS:3250 LAKEPORT BLVD. P.O. BOX 1329; KLAMATH FALLS, OREGON 97601PHONE:541-885-7412 OR 800-535-3936FAX:541-884-3331WEB:WWW.JELD-WEN.COMMULTI SLIDE DOORS & STOREFRONTMANUFACTURER:WESTERN WINDOW SYSTEMSPRODUCT: SERIES 600 & STOREFRONT SYSTEMSADDRESS: 5621 S. 25TH ST., PHOENIX, AZ 85040PHONE: 877.268.1300WEB: WWW.WESTERNWINDOWSYSTEMS.COMWOOD SIDING:MANUFACTURER: TBDCOLOR: TBDAPPLICATION: TBDCODE: TBDROOFING:PRODUCT: TBDMFGR:TBDCOLOR: TO BE APPROVED BY ARCH. & OWNERAPPLICATION: TBDCODE:ICC # ESR-_____WEIGHT: ???? LBS./S.F.GUTTERS:MATERIAL: METAL -COPPER/ALUM. PAINTED KYNARSHAPE: HALF ROUND/SQUARE (5") (VERIFY W/. ARCH.)GARAGE DOORS:SUPPLIER:RANCH HOUSE DOORSWEB:WWW.RANCHHOUSEDOORS.COMSTYLE: CUSTOMMATERIAL: CUSTOM BUILT, WOOD & GLASSWATERPROOF DECK MEMBRANE:MFGR:TUFFLEX POLYMERSADDRESS:10880 POPLAR AVE., FONTANA, CAPHONE: 909.349.2016WEB:WWW.TUFFLEXPOLYMERS.COMCODE:ICC # ESR-2505FLASHING & WEATHERSTRIPPINGPROVIDE CORROSION-RESISTANCE METAL FLASHING PER CRC FOR ALL EXTERIOR FLASHING, MIN. 24 GUAGE COPPER (16 OZ.) SHEETS U.N.O. IN CRC OR MFGR. INSTALLATION GUIDELINES. ALL METALIN CONTACTS TO BE OF SIMILAR TYPE TO AVOID GALVANIC CORROSION. VERIFY W/. ARCHITECT ANY UNCONVENTIONAL ENVELOPE WATERPROOFING AREAS PRIOR TO INSTALLATION1. FENESTRATIONS MUST HAVE TEMPORARY AND PERMANENT LABELS.2. REF. ROOF PLAN (A-3.0) FOR ALL PLATE HTS. & RIDGE HTS.FIRST LEVEL F.F.9.13'FIRST LEVEL F.F.9.13'ROOF PLATE35.76'ROOF PLATE35.76'MAX. HT.38.00'MAX. HT.38.00'MAX. FLAT33.00'MAX. FLAT33.00'GRADE PLANE9.00'FIRST LEVEL T.O.S.9.00'FIRST LEVEL T.O.S.9.00'ROOF DECK F.F.29.46'ROOF DECK F.F.29.46'ROOF DECK T.O.S.29.33'ROOF DECK T.O.S.29.33'ROOF DECK PLATE28.25'ROOF DECK PLATE28.25'MASTER LEVEL F.F.19.83'MASTER LEVEL F.F.19.83'MASTER LEVEL PLATE18.63'MASTER LEVEL PLATE18.63'MASTER LEVEL T.O.S.19.71'MASTER LEVEL T.O.S.19.71'4A-5.01A-5.01A-5.14A-5.1128P.L.P.L.236286' - 5 1/8"1' - 1"8' - 6 1/2"1' - 1"9' - 7 1/2"9' - 7 1/2"10' - 8 1/2"992118ABV. F.F.42" MIN.ABV. F.F.42" MIN.HD. HT.9' - 0"HD. HT.7' - 11 1/4"6' - 3"7' - 8 3/4"3124' - 0"29' - 0"SECOND LEVEL F.F.18.89'SECOND LEVEL F.F.18.89'ROOF PLATE35.76'ROOF PLATE35.76'SECOND LEVEL FLOOR PLATE17.68'SECOND LEVEL FLOOR PLATE17.68'MAX. HT.38.00'MAX. HT.38.00'MAX. FLAT33.00'MAX. FLAT33.00'GRADE PLANE9.00'SECOND LEVEL T.O.S.18.76'SECOND LEVEL T.O.S.18.76'THIRD LEVEL F.F.29.04'THIRD LEVEL F.F.29.04'THIRD LEVEL T.O.S.28.92'THIRD LEVEL T.O.S.28.92'THIRD LEVEL PLATE27.83'THIRD LEVEL PLATE27.83'4A-5.0GARAGE T.O.C.8.00'GARAGE T.O.C.8.00'1A-5.01A-5.14A-5.16P.L.6' - 10 1/8"1' - 1"9' - 0 7/8"1' - 1"9' - 8 1/8"10' - 1 7/8"10' - 9 1/8"3:123:123:123:123:123:1238.00'38.00'38.00'P.L.32677ABV. F.F.42" MIN.312217781137.38'SILL HT.5 1/4"HD. HT.8' - 11 3/8"SILL HT.7' - 2 3/8"HD. HT.8' - 11 3/8"HD. HT.7' - 0"24' - 0"29' - 0"FIRST LEVEL F.F.9.13'SECOND LEVEL F.F.18.89'ROOF PLATE35.76'ROOF PLATE35.76'SECOND LEVEL FLOOR PLATE17.68'2A-5.0MAX. HT.38.00'MAX. HT.38.00'MAX. FLAT33.00'MAX. FLAT33.00'GRADE PLANE9.00'FIRST LEVEL T.O.S.9.00'SECOND LEVEL T.O.S.18.76'ROOF DECK F.F.29.46'ROOF DECK T.O.S.29.33'ROOF DECK PLATE28.25'MASTER LEVEL F.F.19.83'MASTER LEVEL PLATE18.63'MASTER LEVEL T.O.S.19.71'THIRD LEVEL F.F.29.04'THIRD LEVEL T.O.S.28.92'THIRD LEVEL PLATE27.83'9' - 6"GARAGE T.O.C.8.00'3A-5.02A-5.13A-5.112345131211109ABV. F.F.42" MIN.ABV. F.F.42" MIN.1651022238.00'38.00'37.25'37.38'38' - 8"1' - 1"8' - 6 1/2"1' - 1"9' - 7 1/2"9' - 7 1/2"10' - 8 1/2"6' - 10 1/8"1' - 1"9' - 0 7/8"1' - 1"9' - 8 1/8"10' - 1 7/8"10' - 9 1/8"73111112ABV. F.F.42" MIN.24' - 0"29' - 0"DATEREVISIONSOWNER INFORMATION:PROJECT STATUSPLAN CHECK NO.151 KALMUS DRIVE, SUITE G-1COSTA MESA, CA 92626714.754.4040WWW.BRANDONARCHITECTS.COMPROJECT CONTACTTHESE DOCUMENTS ARE THE PROPERTY OF BRANDON ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED, ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A VIOLATION OF BRANDON ARCHITECTS EXPRESSED COMMON LAW COPYRIGHT AND OTHER PROPERTY RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED PERMISSION BY BRANDON ARCHITECTS, WHO SHALL THEN BE HELD HARMLESS AND ABSOLVED OF ANY LIABILITY REGARDING ANY USE OF THESE DOCUMENTS BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED HERON.PROJECT ADDRESS:MATERIAL SPECIFICATIONSAKEYNOTESCGENERAL NOTESBBRANDONARCHITECTS2/16/2022EXTERIORELEVATIONSHEDGE RESIDENCEEDDIE AND DESIREE HEDGE1400 W. BAY AVENUENEWPORT BEACH, CA 92661DD1400 W. BAY AVENUEA-4.0**0000-2021**JEFF VAN VOORHIS1/4" = 1'-0"1NORTH ELEVATION1STUCCO FINISH - MIN. 7/8" THK. W/. DIA. LATH, COLOR AS SEL., REF. MAT. SCHEDULE A-4.02RAKED STONE VENEER - REF. MAT. SCHEDULE SHT. A-4.03WOOD PANEL SIDING - EXT. GRADE MDX, PAINT AS SEL., REF. MATERIAL SCHEDULE SHT. A-4.04GUTTER - ALUMINUM W/. KYNAR FINISH, SHAPE AS SEL. - PROVIDE SHOP DWGS. TO ARCH.5DOWNSPOUT - ALUMINUM W/. KYNAR FINISH OR EQUIV. - AS SEL. (ARCH. TO APPROVE)6STANDING SEAM METAL ROOFING - REF. MAT. SCHEDULE SHT. A-4.07(N.) WOOD GATE - AS SELECTED (MAX. 6' HT. ABOVE NATURAL GRADE)8(N.) PROPERTY LINE FENCE - WD. O/. CONCRETE CURB & FTG. TYP. U.N.O. - PAINT TO MATCH EXTERIOR (MAX. 6' ABV. N.G.)[ON OWNER'S SIDE]9T&G PANELING, REVEAL AS SEL. FINISH AS SELECTED - REF. MATERIAL SCHEDULE SHT. A-4.010EXTERIOR GLASS GUARDRAIL - TEMPERED & LAMINATED - MIN. 42" HIGH - 4" MAX. SPHERE OPENING, REF. DTL. 4/AD-111EXPOSED STEEL COLUMN SIZE PER STRUCT. DWGS., PAINT AND SEAL AS REQ'D.12EXPOSED STEEL BEAM SIZE PER STRUCT. DWGS., PAINT AND SEAL AS REQ'D. - COORDINATE W/. INTERIOR.1/4" = 1'-0"2EAST ELEVATION1/4" = 1'-0"3WEST ELEVATIONNO. REVISION DATE1/4" = 1'-0"4SOUTH ELEVATIONPA2022-0187