Water Efficient Landscape Ordinance Irrigation Audit
Proiect Narhe: 433 Isabella Terrace
Address: 433 Isabella Terrace
City, State Newport Beach, CA 92625
This is to acknowledge that an irrigation audit has been performed in accordance with the Water Efficient
Landscape Ordinance. Observable components of the irrigation system installation and their operation
were acceptable as is generally found in similar irrigation projects. The audit results found that the
contractor met the criteria and irrigation specifications of the approved Landscape Documentation
Package. The Estimated Total Water Use calculated for the irrigation system meets the Maximum
Applied Water Allowance requirement and will continue to do so as long as the irrigation system is
properly maintained and managed.
Signature
P446A
Date: November 18, 2021
Name (print): ayne Graf
Phone: 760-579-9611 cell
Email: grafirrigation@cox.net
Certification ID #: 41834
Certified Landscape Irrigation Auditor (CLIA)
Certified Landscape Water Manager (CLWM)
Company: Graf Irrigation Services
Title: Owner
Address: 228'Monarch Way, Oceanside, CA 92057
Model Water Efficient Landscape Ordinance Irrigation Audit
Project:
433Isabella Terrace
Address:
433 Isabella Terrace
Date:
11/18/21
City,State:
Newport Beach, CA 92625
Auditor:
Wayne Graf
CLIA #
41834
Page
1
of
6
Water Source Data and Equipment Verification
Water Source:
X
Potable
Reclaimed
Well
Pond
Other
oaua"Uw: I Anti -siphon valves are installed for backflow Dreventinn
Controller:
Manufacturer:
Hunter
Model:
Pro-HC
Serial Number:
Mounting:
X
Wall
1
IPeclestal
Other
Options in use:
Central Control
Yes
X
No
Smart Controller
X
Yes
No
2-Wire Option
Yes
X
No
Cycle/Soak
Yes
X
No
Rain Delay
Yes
X
No
Weather Sensor
Flow Monitoring
X
Yes
Yes
X
No
No
Weather data provided through Hydrawise
Master Valve
X
Yes I
lNo
Radio Remote
X
Yes
No
Accessible through wireless device
Manufacturer: Weather data provided through Hydrawise
Model: Serial Number:
Water Efficient Landscape Ordinance Irrigation Audit
Project:
433 Isabella Terrace
Date:
11/18/21
Address:
433 Isabella Terrace
Auditor:
lWayne Graf
City,State:
Newport Beach, CA 92625
JCLIA#
141834
Page
I2
of
6
Site Components Installation and Operation
(✓or P) Pass (F or X) Fail (NA or-) Not Applicable
Component
Installation
Operation
Programmed
Final
Controller
✓
✓
✓
P
Controller Grounding
Controller Enclosure
Communication modem
Antenna(s)
Water Meter (source)
Irrigation is supplied by house meter
Irrigation Sub -meter
Not required. Less than 5000 sq ft of irrigated landscape.
Backflow
Anti -siphon valves are installed for backflow
protection
Wye Strainer
Pressure Regulator
Backflow Enclosure
Booster Pump
Booster Pump Enclosure
Isolation Valve(s)
✓
✓
P
Master Valve
✓
✓
✓
P
Flow Sensor
Not required. Less than 5,000 sq ft of irrigated landscape.
Weather Sensor/Rain
Weather data provided through Hydrawise
Soil Moisture Sensor
-
Radio Remote
Wireless device can be used to operate controller remotely
Basket Strainer
Test Station
Fertilizer Injector
Water Efficient Landscape Ordinance Irrigation Audit
Project:
433 Isabella Terrace
Date:
11/18/21
Address:
433 Isabella Terrace
Auditor:
Wayne Graf
City,State:
Newport Beach, CA 92625
CLIA #
41834
Page
3
of
6
Irrigation Schedule - ESTABLISHMENT PERIOD
# I A-1 I B-2
1
2
3
4
5
6
7
8
9
30
11
12
13
14
15
16
17
18
19
20
21
22
23
24
n
Station # I A-1
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
Note: Adjust irrigation schedule at the end of the establishment
E-5 I F-6 I G-7
Water Efficient Landscape Ordinance Irrigation Audit
Project:
1433 Isabella Terrace
I Date:
11/18/21
Address:
1433 Isabella Terrace
Auditor:
Wayne Graf
City,State:
Newport Beach, CA 92625
ICLIA #
141834
Page
4
1 of
6
Installation and Operation
(✓or P) Pass (X or F) Fail (NA or-) Not Applicable
1
1 2
3
4
5
6
7
8
9
10
11
12
Plant Type (T,P, Tr, GC)
S
S
S
S
X
S
S
Irrigation Type (S,R,B,MS,D)
D
D
D
D
X
MS
MS
Valve Installation
✓
✓
✓
✓
✓
✓
✓
Valve Operation
✓
✓
✓
✓
-
✓
✓
Valve IDTag
-
-
-
-
C
_
-
Valve Box Installation
-
A
Valve Box ID
-
P
Quick Coupler Valve
-
P
Waterproof Wire Splice
✓
✓
✓
✓
E
✓
✓
Valve Leak
✓
✓
✓
✓
p
✓
✓
Sprinkler/Riser Installation
N
✓
✓
Crooked Sprinklers/risers
O
✓
✓
Sprinkler Spacing
(head -to -head)
T
✓
✓
Matched Precipitation Nozzles
✓
✓
Correct Nozzles/Bubblers/Emitters
I
✓
✓
Spray arc alignment
N
✓
✓
Clogged nozzle/emitter
✓
✓
Low Head Drainage
u
✓
✓
S
High Pressure
✓
✓
✓
✓
E
✓
✓
Low Pressure
✓
✓
✓
✓
✓
✓
Overspray
✓
✓
Runoff
✓
✓
✓
✓
✓
✓
Standing Water
✓
✓
✓
✓
✓
✓
Mainline Pipe Leak
✓
✓
✓
✓
✓
✓
Lateral Pipe Leak
✓
✓
✓
✓
✓
✓
Sprinkler Leak
✓
✓
Nozzle Leak
✓
✓
2-Wire Cable
2-Wire Decoder
2-Wire Grounding/Surge Protection
Dripline Installation
✓
✓
✓
✓
Drip Indicator
Drip Filter
✓
✓
✓
✓
✓
Pressure Regulation
✓
✓
✓
✓
✓
Flush Valve
-
Flush Valve Box ID
-
Air Relief Valve
-
Air Relief Valve Box ID
-
Emitter Installation
✓
✓
✓
Dripline Leak
✓
✓
✓
✓
Soil Moisture Sensor
_
FINAL
P
P
P
P
P
P
P
Water Efficient Landscape Ordinance Irrigation Audit
Project:
433 Isabella Terrace
Date:
11/18/21
Address:
433 Isabella Terrace
Auditor:
Wayne Graf
City,State:
Newport Beach, CA 92625
CLIA #
41834
Page
5
of
6
Hydrozone Table
Controller
Hydrozone
Valve
Irrigation
Plant
Hydrozone
#
#
Type*
#
Method**
Factor (PF)
Area (sq.ft.)
%
A
1
MWU
1,2,4
DRIP
0.5
1,580.0
29.8%
A
2
LWU
3
DRIP
0.3
75.0
1.4%
A
3
MWU
6,7
ROTATOR
0.5
1,139.0
21.5%
A
4
ARTTURF
NONE
2,513.0
47.4%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
0.0%
Total
5,307.0
100.0%
Hydrozone*
VLWU = very low water use
LWU = low water use
MW = moderate water use
HW = high wter use
Irrigation Method**
MS = micro -spray
S = spray
MSR = multi -stream rotator
R = rotor
B = bubbler
D=drip
0 = other
Special Landscape Area (sq. ft.)
Recycled
Pool
Spa
Fountain
Other
Total
0
Water Efficient Landscape Ordinance Irrigation Audit
Project:
433 Isabella Terrace
Date:
11/18/21
Address:
433 Isabella Terrace
Auditor:
Wayne Graf
City,State:
Newport Beach, CA 92625
CLIA #
41834
Page
6
1 of 1 6
MAWA and ETWU Calculations
Reference Evapotranspiration ET)
44.9
Hydrozone Category (a)
PF- Plant Factor
Irrigation Method (b)
IE-Irrigation Efficiency ( c )
Very Low Water Use
0.0 - 0.1
Filler Pipe
1.00
Low Water Use
0.2 - 0.3
Drip/Subsurface
0.81
Moderate Water Use
0.4- 0.6
Bubblers
0.81
High Water Use
0.7 - 1.0
Rotors
0.75
Rotators
0.76
Overhead Spray
0.75
ETWU (d) = ETo x 0.62 x ETAF x Area
MAWA = (Eto)(0.62)((ETAF
xLA)+((1-ETAF)xSLA))
ETo - Evapotranspiration rate
LA - total landscape of all hydrozone areas-sq.ft.
0.62 - conversion factor to gallons per sq. ft.
SLA -total landscape area in sq ft
ETAF - Plant Factor/Irrigation Efficiency
ETAF - 0.55 for residential areas
Area - Landscape Area for each hydrozone
ETAF - 0.45 for non-residential areas
Hydrozone (a)
PF
Irr Type
IE
ETAF
Landscape Area
ETAF x LA
ETWU
MWU DRIP
0.5
DRIP
0.81
0.62
1,580
975
27,151
LWU DRIP
0.3
DRIP
0.81
0.37
75
28
773
MWU ROTATOR
0.5
ROTATOR
0.76
0.66
1,139
749
20,860
ART TURF (FUTURE)
0
none
0.00
0.00
2,513
0
0
0.00
0
0
0.00
0
0
0.00
0
0
0.00
0
0
0.00
0
0
0.00
0
0
0.00
0
0
0.00
0
0
TotalIE
2.38
Totals
5,307
1,752
48,784
Special Landscape Areas
SLA
1.00
0
0
0
Totals
0
0
0
Estimated Total Water Use (ETWU) Total
48,784
Site ETAF
0.55
Maximum Applied Water Allowance (MAWA)
81,255
Hydrozones (city)
1 3
Irrigation Efficiency (IE) Average
0.79
ETAF CALCULATIONS
Regular Landscape Areas
Totals
All Landscape Areas
Totals
Total ETAF x Area
(B) =
1,752
Total ETAF x Area
(B+D) =
1,752
Total Area
(A) =
5,307
ITotal
Area
(A+C) =
5,307
Average ETAF
(B)/(A) =
0.33
ISite
wide ETAF I
(B+D)/(A+C) =
0.33
ETWU is less than or equal to MAWA and complies with WELO requirements