HomeMy WebLinkAboutX2021-2265 - Alternative Material & Methodso�� ae X����' deb, �co MU ey
EWPp CITY OF NEWPORT BEACH ��a
,` i> COMMUNITY DEVELOPMENT DEPARTMENT /qh F�OI'MFN
u jCy a BUILDING DIVISION 2
�0f 100 Civic Center Drive I P.O. Box 1768 1 Newport Beach, CA 92658-8915 �023
Cq�/F00.��P www.newoorlbeachca.gov, 1 (949) 644-3200
NEu._Cftl'n„
CASE NO.: co
Bch
FOR STAFF USE ONLY
AEQUES79F(OR TITLE MODIFICATION TO PROVISIONS
TITLEFIRECODE) OR TITLE 15 (BUILDING CODE)THE NEWPORT BEACH MUNICIPAL CODE
(See Reverse for Basis for Approval) (Fee $291)
Plan Check# I1 rJ 7—do;tl # of Stories 3
Occupancy Classifica8on R3 U
Use of Building DV PbHX # of Units a1
Project Status PL
■ REQUEST FOR ALTERNATE MATERIAL
OR METHOD OF CONSTRUCTION
(See Reverse for Basis for Approval) (Fee $291)
Construction Type V-13
Verified by D.R.M.
No. of Items 1I�
Fee due �/ aq-%
For above requests, complete Sections 1, 2 & 3
below by printing in ink or typing.
DISTRIBUTION:
❑ Owner 19 Plan Check F •S.
❑ Petitioner ❑ Inspector
❑ Fire ❑ Other
JOB ADDRESS:
PETITIONER:
SITE ADDRESS: 601 JASMINE AVENUE
PetifionerKARL F DAKTERIS, ARCHITECT
owner DR. DESIREE EDLUND
Address 518 JASMINE AV
NEWPORT BEACH, CA 92625
Zip #1957-2021-2021 46
Daytime Phone )
PLAN CHECK
(Pamoner M be architect or engineer)
Address 1960 SAN BRUNO
NEWPORT BEACH, CA Zip 92660
Daytime Phone (949) 702-3573
Email: KARLO.KARLDAKTERISARCHITECTSC
2 REQUEST: Submit plans if necessary to illustrate request. Additional sheets or data may be attached.
REQUEST TO HAVE UNIT 1 MASTER BEDROOM EMERGENCY ESCAPE & RESCUE OPENING OPEN ON TO
A COVERED DECK FOR EGRESS TO A YARD UNOBSTRUCTED FROM GROUND TO SKY
3 USTIFICATION/FINDINGS OF EQUIVALENCY:
CODE SECTIONS:
CRC R202, R310
UNIT 1 MASTER BEDROOM COVERED DECK WILL HAVE 1 HR. FIRE RATED DECK ASSEMBLIES PER DETAIL IN
ICC ESR-2505 SECTION 4.6 FOR EXCEL FIRE COAT DECK COATING SYSTEM CLASS A W/ 5/8" DENS GLASS
AT CEILING. THIS FIRE PROTECTION ABOVE & BELOW THE EGRESS PATH WILL PROVIDE EQUIVALENT
PROTECTION TO AN EERO WHICH OPENS DIRECTLY TO A YARD UNOBSTRUCTED FROM GROUND TO SKY.
Peti9oner': Position ARCHITECT
Signature-�� ` CA Professional Lic. # C-21769 Date: 01/22/2023
FOR STAFF USE ONLY
DEPARTMENT ACTION: In accordance with: ❑ CBC 104.11/CFC 104.9 104.10/CFC 104.8
�fCBC
(Alternate materials & methods) (CBC Modification)
❑ Concurrence from Fire Cade Official is required. ❑ Approved ❑ Disapproved ❑ written Comments Attached
i -� By: Date
,Lry(tequest (DOES) DOES_NO�T) lessen any fire protection requirements.
KRequest (DOES)(DOES NOJ) lessen the structural integrity
The Request is: Granted ❑ Denied (See reverse for appeal information)
❑ Granted (Ratification required)
Conditions of Approval:
Sign turn a / PositiorHIEFBUILDINOOrrICIA[Date
PrintName F�2NCc-11-h?�
APPEAL OF DIVISION ACTION TO THE BUILDING BOARD OF APPEALS (See Reverse)
(Signature, statement of owner or applicant, statement of reasons for appeal and filing fees are required.)
CASHIER RECEIPT NUMBER: �, L� �� �� L I r �� Forms\modif 07/01/21
Guidelines for Approval of Alternate Materials. Desian and Methods of Construction
Basis For Approval
For the Chief Building Official and Fire Code Official or their designated agent to approve a request for modification
or a request for alternate material or method of construction, he/she must determine that special, individual reasons
exist that make compliance with the strict letter of the Code impractical and that equivalency is provided. The
resulting condition must be in conformance with the spirit and purpose of the Code provisions involved and that such
modification does not lessen fire protection, structural integrity or occupant safety. The applicant must provide
sufficient information with this application to allow the above evaluation to be made.
Requirements for Submittals
The applicant design professional shall prepare a Written Report that describes the alternate proposal along with the
applicable data listed below:
• State specific code provisions for which alternative is requested and why request is being submitted.
• Describe by code section those provisions for which alternative is desired.
• Compare the proposed alternative versus the code requirements in terms of structural strength, suitability,
effectiveness, fire resistance, safety and health impacts affecting the building or user of the building.
• Demonstrate that the proposed alternative is compatible with balance of code requirements.
• When applicable, specify how authoritative consensus document(s) are used to substantiate proposal.
(Reference draft ICC Building Performance Code Commentary Section 1.4.2.3 for background information).
• Provide assumptions, references, and documentation of evaluation methods utilized. This includes intended
use, input data, anticipated outputs, and limitations of computer models and other analytical tools or methods.
• Specify when and where special inspection and testing are required and the standards of acceptance for
demonstrating compliance. Show how the proposed alternate, if accepted, will be identified on the job site.
• Where land use restrictions and building setbacks are required, deed restrictions may be an appropriate method
to ensure continued compliance.
• State how and where alternate proposal is incorporated within construction plans and prepare plan amendments
as necessary. The design professional has the responsibility to coordinate all construction documents and
ensure compatibility between documents.
• The report and design documents shall be dated, signed and stamped by the design professional according to
the plan submittal procedure.
• For alternate methods of design requests, the applicant shall set performance criteria for his design.
Performance criteria shall be reviewed, amended and approved by the Building or Fire Code Official prior to
start of design.
Alternative Design Review/Verification
The Chief Building Official or Fire Code Official has the responsibility to review design submittals for compliance to
the adopted codes and. procedures. If the Building or Fire Code Official does not have the expertise on staff to
make a thorough and competent review, the Building or Fire Code Official shall select a consultant that possesses
the necessary qualifications to perform a third -party or peer review. Cost of peer review shall be paid by applicant to
the Building Division prior to commencing the review.
• Verify that all applicable information and justifications listed above as requirements for submittals is received and
verify that evaluation and design methods used by designer are appropriate to the alternative proposed.
• Verify products are being used in accordance with their listing conditions as required by recognized listing
agencies. If not available, require documentation and/or testing to demonstrate compliance with intent of code
and intended use.
• Evaluate performance of material and possible flaws that could affect performance of material in its installed
state.
• The reviewer shall document that the submittal has been reviewed and accepted as meeting the alternative
materials, design and methods of construction provisions of the code. If the Building or Fire Code Official is not
satisfied that the applicant has met the conditions, the request should be denied in writing with the applicable
reason(s).
Inspection/Field Verification
The alternate proposal as approved in the construction documents must be verified by inspection, and, where
necessary, testing as follows:
• To verify that alternate materials, systems and fabricated products comply with accepted design criteria and the
manufacturer's and engineer's installation procedures, inspectors should check product labeling, certification,
quality assurance processes, and testing, as applicable.
• When appropriate, an approved third party quality assurance inspection and testing service may be required for
continuous and complex inspection and testing activities. This is intended to verify that construction complies
with the code and the approved plans.
Appeal from the determination or action of the Chief Building Official or Fire Code Official or their designated agent
may be made to the Building and Fire Board of Appeals. To appeal, the applicant must provide special individual
reasons that make compliance with the strict letter of the Code impractical. Appeals or ratifications pertaining to
State Disabled Access Standards require complete evidence to substantiate that the proposed design is equivalent
to that prescribed by that standards or that due to legal or physical constraints, compliance with the standards or
providing equivalency would create an unreasonable hardship.
Appeals must be submitted on the Appeal Form available at Permit Counter accompanied by the proper fee. You
will be notified in writing of the appeal hearing's time and date.
H3
EILING
WALK
TENT WAI
0
d$1l
F
L2
-----!-------.-
i_.. _ 51
i
i I
UNIT 1
LIVING LEVEL
10'-0" CLG.
F F. 11640
,. 5S(1ncc 51. III
D
9 a
O 152 ��0-
OI / i UNIT 1�`-�
SjO�II;r— —ENTRY PORCH
O/I GLASS FLOORABOVE BASEMENT I
9 0 CLG.
52
��
- \ d
W� 6
Z
20'-0" CLEAR TO
-1"
SH FRONT SETBACK
ZJ LOW PATIO WALL +3T.W. 11
L40 \ _ B B Q REF.
j
I
� I
� I
�
I�
E
I
NIT 1
PATIO
li F.F. 115.92
I� CONC. PATIO
li DRAIN PER CIVIL
PLANTER\'
SEAT WALE.
i
,- T i �I -
EXIST
PALM N �
PALMS
j 3RD STREET
.5)
J PATIO
`T
EXISTING
EXISTING
,I
SIDEWALK
PARKWAY
n
0G '
I'
i
i
i
I
FIRST LEVEL BELOW MASTER BEDROOM
UNIT 1
M. BATH
8'-6" CEILING
P.F.
oV
ch MZ
25 )r—I%` ■ I I
YD4
30 W1C ;U
407'-b"CLG, I� 1
-10 37,-HWD. FLR. Im
224041
1
(21� �20
i 7 6'CLG 44,, MASTER BR 5 HR. RATED
8'-6" CLG I .A9.5;
HWD. FLR.
F.F. 127.00
I9
—1I- T_6"CLG57
221 '❑7
TS�—+0.0 1
51 � 0 I jy 1
2 SIDE —' Co.
60
MASTER
F.S. 127.00
PST P.
�.. CRICKET �YI'�S• I
60 �� D.D.IJO.S. _ GLASS GUARDRAIL 60'
-----------------'
�5 �... 57
SIM. 5..,.y3 1 HR. RATED i. $-0"
_ K
A6.22
PLAN FOR NOTES
UNIT 1 MASTER BEDROOM AT 2ND LEVEL
SO 58
UNIT 1
=SDECK 57. OPEN ROOF DECK
F.S. 137.16
61 P.T. P.
WF BEAM ABOVE
L
VE TOP EAVE T44.16 CA6-01
PARAPET 140.66 GLASS GUARDRAIL
I
O
�
---�`_ t- --
0,,,,I
O
w
w
ZJ
Y
w Z
V
w
�
l7 W
LL
O
{¢L
15 FT. ADDITIONAL SETBACK FOR 3RD FLR.
TO "ENCLOSED S.F."
o.
Q,.o I
Q/
oU
I
1 I
E
v
I�
I M
0
v
ri
SHADE _
CANOPY a
BELOW
F.S. 136.671
� � I
� u w _
inQ �p
E w )
20 FT. 5
is �
IST/2ND FLR.
_ K
.A6.2)
L A6.2;
ROOF DECK AT 3RD LEVEL ABOVE MASTER BEDROOM
--TOP OF EAVE 144.16
BOTT. OF EAVE
5❑ a�
7
CV
I,
4 0
M
00 3rd FLR. FIN. D»QK_
3rd FLR STRUCT IJ_ECK _
__ 2ndFLRPL.
SOFFIT -I'
1 HR. ROOF/DECK3/A9.5I /
p 8
Eo o 48
00 C
12 [246 o
2nd FLR_ _
- — 1 sty PL. _
SOFFIT
1 HR. DECK 5/A9.3A
41 122.0
UNIT 1
DECIF.,
8'-0" CL
o O 48 UNIT 1
PORCH
9'-0" CEILING
41 36
43
—� 114.50 SIDEEW
WALK
MIN. BASEMENT
SETBACK
TOP OFRIDGE 746.25
3�
TOP O_F EAVE 144.50_
UNIT 1
UNIT 1 UNIT 1
MBR. WIC
8'-6" CLG. 7-6" CLG.
UNIT I
GREAT ROOM M
10'-0" CEILING `
UNIT 1
BASEMENT
8'-10" CEILING
SECTION AI
MASTER BEDROOM SECTION A
9A iv
8 it)
FS.137.16_
F.5.736.50
lop
63 25 -1 C/A9.3
F.P. ENCROACHMENT
2'-0" MIN. SETBACK
_ _F.S.127.00r_i
34 E.G. 119.63
E.S. 119.78
E.F.F.120.16
�z
78 I I g
, M
F.P. 40 i�'»� �
��
BASEMENT
_ F.S.106.00 _
TOP RIDGE 146.25
2
TOP EAVE 144.16
3 11 ❑5
_ - _ PARAPET BEYOND 141.75_ _ _
(ERED ROOF DECK UNIT __ PARAPET 140.66__
G CLG. OPEN ROOF DECK GLASS GUARDRAIL—] 40.66__
A Z,o
4
2 M
3rd FIr. FIN. DECK F.S.137.16 _
UNIT 1 3rdFIr STRUCT DECKK
UNIT 12nd FIr. PLATE____
SOFFIT
UNIT 1 UNIT 1_ VARIES 4'-9" TO V-9"
BR 3 (13AB
8'-6" CLG. 8'-6" CLG. b ;p
14 -2" RECESS -ro' ep
13
UNIT 1 2nd Flr F.S. 127.0 _
UNIT IIstFIrPL.
_
SOFFIT
25
UNIT 1 UNIT 1 -
LIVING LEVEL
10'-0^ CLG. PATIO o- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -F o
__
a
1.+F1. Ff 11Rn cI llc, _
UNIT ii'-
--
BASEMENT ii
8'-10" CLG. =
SECTION K
MASTER BEDROOM SECTION K
JASMINE
STREET
3/4"CLEAR LAMINATED/TEMPERED
VARIES, SEE ROOF PLAN
GLASS SET IN BASE SHOE PER MANUF.
SPECS AND DETAILS. GLASS TO HAVE
EASED AND POLISHED EDGES. GLASS
PANELS SET 2" APART MAX. AND MAX PANEL
NOTE:
1.1 HOUR RATED DECK ASSEMBLY. UL DES
L512, REF. B-53.
LENGTH 48". SEE ELEV FOR SPACING.
2. GUARDRAIL TO RESIST MIN. LATERAL LOAD
PER CBC, LDF=
ALUM ANOD. BASE SHOE. SECURED TO
1.0. SEE STRUCT, AND MANUF. CALCS AND
I.OADS.
CURB PER MANUF. SPECS AND DETAILS.
3. PACK DECK FRAMING W/ INSULATION PEf
Z CRC 806.5.5.1.3.
W/ TILT LOCK TECH.
IMPERMABLE R-5 RIGID OR SPRAY TO UND
RSIDE OF SHTH'G.
3/16" THK. NEOPRENE GASKET SEPARATION.
8 REMAINING T-24 REQ'D W/ PERMEABLE B
TT INSULATION.
3/8" LAG SCREWS AT 12" O.C. SET W/
SEALANT INTO BUILT UP CURB.
EXCEL FIRE COAT DECK
S.S. 316-2818 GA. FLASHG 0/ EXCEL
WATER -PROOFING WRAPPED
WATERPROOFING 0/ BLUESKIN S.A.F.
OVER BUILT UP CURB
PORCELAIN TILE 2CM FINISH DECK SET ON
ADJ. PEDESTALS, INSTALL PER MFR SPECS.
SET ON, EXCEL 1 HR FIRE COATCLASS A W.P.
--
_______
DECKING SYSTEM PER, SLOPE PER PLAN
INSTALL PER MFR. SPECS.
3rd FLR. FIN. DECK- UNIT 1 __
____
METAL STOP FOR EXCEL DECK
j
WATERPROOFING
I
,
3rd FLR STRUCT REAR DECK
— —
4„
-
316S.S. 24 GA. RECESSED MTL
------------ --------
--- - -
-------------
GUTTER W/ SCREEN. SLOPE TO DRAIN
TO INTERNAL D.S. PER ROOF PLAN
t-
3/4" MIN. EXT. GR. T.G.
CRICKET
3rd FLR STRUCT VIEW DECK
____________
PLYWOOD ROOF
SHEATHING
—
BLUESKIN SAF 0/ SHEATHING
AND WRAP OVER INTO WRAP BLUESKIN SAF 0/ CURB 0/ CRICKET
GUTTER RECESS THRU OUT. GUTTER 'o AND DOWN THRU OUT GUTTER AND OVER
FASCIA. OVERLAP MIN.6"
16 GA. RIGID G-90 MTL. C-►
CHANNEL PANEL. HIDDEN BRACKET ATTACHMENT. BEAM PER STRUCTURAL.
FLUROPON CLASSIC II
"EVENING SHADE" COLOR.
SEE ELEVATIONS FOR
SEAMS. OVERLAP SEAMS CUT JOIST FOR RECESSED GUTTER.
6" MIN. APPLY PLYWOOD.
INTERNAL D.S. TO WALL & TO
GRADE. SEE ROOF PLAN AND ELEV.
2nd FLR PL. +8'-6"
SOFFIT FRAMING + 8'-1 5"
SOFFIT FINISH + 8'-0"
P.T. 1 x 2 BLOCK
2 x SOFFIT FURRING
DENS GLASS
TRESPA PURA SIDING
CEILING, INSTALL PER
MANUF INSTRUCTIONS.
AWNING FLAT ROOF AT DECK GLASS GUARDRAIL CURB
MASTER BEDROOM DECK CEILING
BRUSHED S.S. 316 20 GA.
FLASHG 0/ C.R. 24 GA. B,
FLASH
WRAP EXCEL FIRE COAT
OVER TOP OF CURB
TILE 2CM
FLAN - IN6 I ALL PER
MFR. SPECS SL. MTL. L STOP
2ND FLR. N FOR ROOFIN
F.F. AND
FIN. DECK 2ND FLR, F.F.
aI
DECK OPE
ATTH S D P.T. STUCCO
STOP
R
3/4" MIN. EXT. GR. T.G.
0
PLYWOOD ROOF:
CRICKET
SHEATHING
BOTT. OF
WRAP SAF 0/ CURB 0 DECK SLOPE
CRICKET AND DOWN
FRONT 0/ SHEATHING
RIPPED DECK FLOOR
JOIST FOR SLOPE, SEE
PLAN, SEE STRUCTURAL
2x NAILER AT TOP & BOTT. OF 1ST FLR. PL.
STL, BM. SEE STRUCTURAL +
JOIST HANGER, SEE 27/ 2" CLR. LAM.
STRUCTURAL TEMP. GLASS SET Wl
S.S. STANDOFFS PER
MANUF. SPECS &
DETAILS, AGN.5B. &
2x NAILER AT SIDE OF STL. BM. ESR3842. GLASS
PANELS SPACED
EQUAL & V APART MIN.
II MAX PANEL WIDTH 36".
2x6 SOFF. JOIST@ STEEL BEAM Wl BOLTS
16" O.C. FOR NAILERS, SEE
P.T. 1 x 4.5 BLOCK STRUCT.
DENS GLASS
SECTION
SOFF. FRAM'G. + 9'-1.5"
FINISH SOFFIT + 9'-0"
S.S. MLCOR STUCCO
NOTE: ASING PEAD IAll lArFF
1. OUR RATED DECK ASSEMBLY. UL DES L512, REF. B53.
TRESPA PURA SIDING 2. GUARDRAIL TO RESIST MIN. LATERAL LOAD PER CBC, LDF=
CEILING, INSTALL PER 1.0. SEE STRUCT. AND MANUF. CALCS AND LOADS.
MANUF INSTRUCTIONS. 3. PACK FRAMING W/ INSULATION PER CRC 806.6.5.1.3.
IMPERIVIABLE R-5 RIGID OR SPRAY TO UNDERSIDE OF SHTH'G
& REMAINING T-24 REQ-D W/ PERMEABLE BATT INSULATION.
DECK GLASS GUARDRAIL @ RATED DECK 3-1'4-
@ CORNER COLUMN & EXT. SOFFIT (5
MASTER BEDROOM DECK FLOOR
i/A9.3A
I
FLOOR -CEILING SYSTEMS, WOOD -FRAMED
GA FILE NO. FC 5410 GENERIC 1 HOUR 35 t 339 STC
WOOD JOISTS, GYPSUM WALLBOARD FIRE SOUND
One layer 1/2" type X gypsum wallboard or gypsum veneer base applied at right angles
to 2 x 10 wood joists 16" o.c. with 5d nails, 1 5/8" long, 0.099 shank, 1/4" heads, 6" o.c. II I
Nails placed 3/4" from board edge joints and 1/2" from board end joints. Wood joists
supporting 1" nominal T & G wood subfloor and 1" nominal wood finish floor, or 19132"
plywood finished floor with long edges T & Gand 15/32" interior plywood with exterior
glue subfloor perpendicular to joists with joints staggered..
Approx. Ceiling
Weight:
2 psf
Fire Test:
UL R1319-66, 11-9-64,
UL Design L512;
UL R3501-45, 5-27-65,
UL Design L522;
UL R2717-38, 6-10-65,
UL Design L503;
UL R3543-6, 11-10-65,
UL Design L519,
ULC Design M502
Sound Test:
NGC 4024, 7-13-66
I IC & Test:
32 (66 C & P)
NGC 5032, 7-19-66