HomeMy WebLinkAboutX2019-3693 - MiscCity of Newport Beach Special Inspector Manual �.R'1'pki CITY OF NEWPOR T BEACH COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION 100 Civic Center Drive I P.O. Box 1768 Newport Beach, CA 92658 www.newoortbeachca.00v (949) 644-3200 Project Address: Permit Number: Inspection Type Inspection Date SPECIAL INSPECTION REPORT L. ( ) Periodic (Continuous To the best of m knowledge, the work inspected was in accordance with the Building Division approved design drawings, specifications anr�applicable workmanshio provisions of the U.B.C. excentns noted. eciall or Signatur ' Date: i Print Full Name: Newport Beach Registration No.: i l 7 67 CITY OF NEWPORT BEACH COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION 3300 Newport Boulevard I P.O. Box 1768 1 Newport Beach, CA 92658 www.newoortbeachca.gov 1 (949) 644-3275 SETBACKS AND TOP OF SLAWFLOOR ELEVATION CERTIFICATE The purpose of this certificate is to insure that the structure is located properly on site per the approved drawings. This certificate also verifies the top of slab/floor elevation noted on the approved drawings. After the top of slab/floor elevation is verified to match the elevation specified on the approved drawings, the contractor and inspector can measure the height of the structure to the top of slab/floor to verify that it is equal or less than the dimension shown on building sections and elevations. This form must be filled out by a registered surveyor or civil engineer authorized to perform surveys. The survey must be done after the concrete forms are in place or preferable after the concrete slab is poured or raised floor is built, but prior to starting wall framing. Engineer/Surveyor's Name Mike Fokert Engineer/Surveyor's Address License # LS 5662 22311 Brookhurst St, Ste 203, H.B. CA 92646 Job Address 369 Santa Isabel Ave. Setbacks: Sketch a site plan and specify surveyed setbacks (use back page). * Top of slab/floor elevation: " N/A * If slab/floor elevation varies, sketch a plan or section through slab on the back page and specify the elevations. Use same datum used in the survey of record. I certify that the setbacks are ®, are not ❑, per City approved plans. Describe any deviations from plans: Retaining wall forms are per plan. I certify that top of slab/floor elevation(s) is ❑, is not ❑, per City approved drawings. Describe any deviations from plans: N/A 3/16117 Date Forms/SetbacksandTopofSlabElevationCert. Project Name & Address Permit Number A Inspection Type(s) Inspection Date(s) Describe Inspectio, List Tests Made: DEPUTY 1 INSPECTION 1-800-DEPUTYI Gen Contr. Sub-Contr 'k",Ok) .{ a:1,, Report of Special Inspection Made, including Locations: t: de c Total Inspection 'rime Each Day: Periodic [ List Items Requiring Correction, include uncorrected items previously listed ] Continuous To the best of my knowledge, the work inspected was in accordance with the Building Department approved design drawings, specifications and applicable workmanship provisions of the U.B.C. except as noted above. ,'- Signed: ��` ��� 214 Date Print Full Name: %i Registration No. FORM S"L90 DEPUTY I INSPECTION 1-800-DEPUTYI Gen Contrl L, Sub-Contr. Report of Special Inspection 6A -V Project Nagle & Address �77 iJ1 �H'3 Inspection Type(s) Inspection Date(s) Continuous Periodic Describe Inspection Made, including Locations: List Tests Made: Total Inspection Time Each Day: Hours List Items Requiring Correction, include uncorrected items previously listed To the best of my knowledge, the work inspected was in accordance with the Building Department approved design drawings, specifications and applicable workmanship provisions of the U.B.C. except as,noted above Y i V Signed; Y' Date Print Full Name: eA� Registration No. J FORM SIAL90 DEPUTY 1 INSPECTION 1-800-DEPUTYi„_( Gen Contr '[ r'A -i „ c cq° ' Sub -Conn Report of Special Inspection Project Name &Address is f f,,f is 3 f..q (4s(•, _ h Permit Number /, ';L O1 "I " 6 (� 7 -> Inspection Type(s) 'Ste Inspection Date(s) t t? ! ! _� [ ] Periodic [ ] Continuous Describe Inspection Made, including Locations: (,;)M4ckul `f c d in v R T"LU FT-( in R c ca-t- 'M List Tests Made: Total Inspection Time Each Day: Date Hours List Items Requiring Correction, include uncorrected items previously listed Comments: To the best of my knowledge, the work inspected was in accordance with the Building Department approved design drawings, specifications and applicable workmanship provisions of the U.B.C. except as noted above ;r/� . rf Signed: U /'/1I Date l U/ 1 �! Print Full Name: ' fi? +�11 } �' �, t Registration No. IV FORM SI-02;90 'VROIlECT NO. CLIENT OR OWNER _ r REPORT NO. TR CYA.OT NO. PROJECTNAME ram' DATE ! i' DAY /_j :6 JOB ADDRESS EARTHWORKC�YNTRACTOR ENGJGEO. LOCATION CLIENT REPRESENTATIVE PERMIT Nd. SUBJECT COMMENTS t t'-! FJ.'i..A! Y. , C 'wsr J� y „, �,.. � J �.til i - o! C' .. ..m -J'—�. �,>_( ,i r u ....... V` ��, 2 No.2253 v EKp.10-31- ) OF GLOBAL GEO-ENGINEERING, INC. 3 Corporate Park, Suite 270 Irvine, CA 92606 Phone 949-221-0900 Fax 949-221-0091 Email: global@globalgeo.net (Signalum) , (Pdni) / TERMS AND CONDITIONS OF AUTHORIZATION Consultant shall serve Client by providing professional counsel and technical advice regarding subsurface conditions consistent with the scope of services agreed -to between the parties. Consultant will use his professional judgment and will perform his services using that degree of care and skill ordinarily exercised under similar circumstances, by reputable foundation engineers and/or engineering geologists practicing in this or similar localities. • In assisting Client, the Consultant may include or rely on information and drawings prepared by others for the purpose of clarification, reference or bidding; however, by including the same, the Consultant assumes no responsibility for the information shown thereon and Client agrees that Consultant is nut responsible for any defects in its services that result from reliance on the information and drawings prepared by others. Consultant shall not be Gable for any incorrect advice; judgment or decision based on any inaccurate information furnished by the Client or any third party, and Client will indemnify Consultant against claims, demands, or liability arising out of, or contribute to, by such information. Unless otherwise negotiated in writing, Client agrees to limit any and all liability, claim for damages, cost of defense, or expenses to the levied against Consultant on account of design defect, corm, omission, or professional negligence to a sum not to exceed ten thousand dollars or charged fees whichever is has. Further, Client agrees to notify any construction contractor or subcontractor who may perform work to connection with any design, report, or study prepared by Consultant of such limitation of Lability for design defects, errors, omissions, or professional negligence, and require as a condition precedent to their performing the work a like limitation of liability on their part as against the Consultant lm the event the Client fails to obtain a like limitation of liability prevision as to design defects, errors, omissions or professional negligence, any liability of the Client and Consultant to such contractor or subcontractor arising out of a negligence shall be allocated between Client and Consultant in such a manner that the aggregate liability of Consultant far such design defects to all parties, including the Client shall not exceed ten thousand dollars or charged fees whichever is less. No warranty, expressed or implied of merchantability or fitness, is made or intended in connection with the work to be performed by Consultant or by the proposal for consulting or other services or by the furnishing of oral or written reports or funding, made by Consultant. The Client agrees, to die fullest extent permitted by law, to indemnify, defend and hold harmless the Consultant, its officers, directors, employees, agents and subconsndlants from and against all claims, damages, liabilities or costs, including reasonable morney's fees and defense costs, of any nature whatsoever arising beat or in connection with the Project to the extent that said claims, damages, liabilities or costs also out of the work, services, or conduct of Client or Client's contractors, subconsulmnts, or other third party not under Consultant's control. Client further agrees that the duty to defend set forth herein arises immediately and is not contingent on a finding of fault against Client or Client's contractors, subconsultants, or other third patties. Client shall not be obligated under this provision —`Tom emniy anso fast or onsad fanT `xx ole—hegligeinde or Will lambs covducC�-- Client shall grant free access to the site for all necessary equipment and personnel and Client shall notify any mid all possessors of the project site that Client has granted Consultant free access to the project site at no charge to Consultant unless expressly agreed to otherwise in writing If Clame is not the property owner for the subject Project, Client agrees that it will notify the property owner of the terms of this agreement and obtain said property owner's approval to the terms and conditions herein. Should Client fail to obtain the property owner's agreement as required herein, Client agrees to be solely responsible to Consultant for all damages, liabilities, costs, including litigation fees and costs, arising from such failure that exceed that limitation of Consultant's liability herein. • Client shall locate for Consultant and shall assume responsibility for the accuracy of his representations as to the locations of all underground utilities and installations. Consultant will not be responsible for damage to any such utilities or installation not so located. • Client and Consultant agree to waive claims against each other for consequential damages arising out of or relating to this agreement Neither perry to this agreement shall assign the contract without the express, written consent of the other party. Consultant agrees to cover all open test holes and place a cover to carry a 200-pound load on each hole prior to leaving project site unattended. Consultant agrees that all test holes will be bacldilled upon completion of the job. However, Client may request test holes to remain open after completion of Consultants work In the event Client agrees to pay for all costs associated with covering and backbiting said lest holes at a later date, and Client shall indemnify, defend and hold bmmless Consultant for all claims, demands and liabilities arising from his request, except for the sole negligence of the Consultant, to the extent permitted by law. - Consultant shall not be responsible for the general safety on the job or for the wurk of Client, Odic, emantoere and third panic, Consultant shah be excused for any delay in completion of the contract caused by acts of God, acts of the Client or Client's agent and/or contractors, inclement weather, labor trouble, acts of public utilities, public bodies, or inspectors, extra work, failure of Client to make payments promptly, or other contingencies unforeseen by Consultant and beyond reasonable control of the Consultant. In the event that either party desires to terminate this contract prior to completion of the project, written motificaton of such intention to terminate must be tendered to the other party. In the event Client notifies Consultant of such intention to terminate Consultant's services poor to completion of the contract, Consultant reserves the right to complete such analysis and records as are necessary to place files in order, to dispose of samples, put equipment in order, and (where considered necessary to protect his professional reputation) to complete a report on the work performed to date. In the event that Consultant incurs cost in Client's termination of this Agreement, a termination charge to cover such cost shall be paid by Client. If the Client is a corporation, the individual or individuals who sign or initial this Contract, on behalf of the Client, guarantee that Client will perform its duties under this Contract. The individual or individuals so signing or initialing this Contract warrant that they are duly authorized agents of the Client. Any notice required or permitted under this Contract may be given by Ordinary mail at the address contained in this Contract, but such address may be changed by written notice given by one party to the other from time to time. Notice shall be deemed received in the ordinary course of the mail. This agreement such be deemed to have been entered into the County of Orange, Stale of California. LIMITATIONS Our findings, interpretations, analyses, and recommendations are professional opinions, prepared and presented in accordance with generally accepted professional practices and are based oa observation, laboratory dam and our professional experience. Consultant does not assume responsibility for the proper execution of the work by others by undertaking the services being provided to Client under this agreement and shall in no way be responsible for the deficiencies or defects in the work performed by others not under ConsulmnPs direct control. No other warranty herein is expressed or implied. DEPUTY IINSPEM N 1-800-DEPUTYI GenContr. fkz1i Sub-Contr: Report of Special Inspection Project Name &Address u" ""t :it:1- � r ra -1-I . �;,A _ Permit Number Rkaw-1 Inspection Type(s) Inspection Date(s) Describe inspection Made, including Locations: List Tests Made: Total Inspection Time Each Day: [ ] Periodic [ ,, ] Continuous Date E f !-t 1( II 1 1 --4 Hours., List Items Requiring Correction, include uncorrected items previously listed To the best of my knowledge, the work inspected was in accordance with the Building. Department approved design drawings, specifications and applicable workmanship provisions of the U.B.C. except as noted above f Signed �,t �':, f':��'1A,��' Data Print Full Name: Registration No FORM SI-02;90 CITY OF NEWPORT BEACH COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION 100 Civic Center Drive I P.O. Box 1768 1 Newport Beach, CA 92658-8915 www.newportbeachca.gov 1 (949) 644-3200 Structural Observation Report Project Address: Report Date: CNB Inspector Name: CNB Permit#: 369 Santa Isabel Avenue November 8, 2022 Chad Shelton X-2019-3693 Building Owner Name: Owner's Mailing Address (if different from site); Owner's Telephone #: CNB Plan Check #: Adrienne Worley 369 Santa Isabel Avenue, NB 9266 949-302-2800 Full Name of Structural Observer (SO): SO E-mail Address: SO Telephone #: SO License / Reg. #: William Hobbs wchobbs@wwdb.org 951-660-9800 RCE 42265 PLEASE INDICATE STRUCTURAL ELEMENTS AND CONNECTIONS OBSERVED check applicable boxes FOUNDATIONS SHEAR WALLS FRAMES DIAPHRAGMS (Floor/Roof) INDICATE LOCATION(S) OBSERVED DATE OBSERVED ® Conventional Footings a6wb ❑ Concrete ❑ Steel ❑ Concrete Rear yard retaining wall 9-16-2022 ❑ Mat Foundation, Prestressed Concrete ❑ Masonry ❑ Concrete ❑ Steel Deck ❑ Caissons, Piles, Grade Beams ❑ Wood or Manuf. Shear Panels ❑ Masonry ❑ Wood ® Other: Ret. wall ❑ Other: ❑ Other: ❑ Other: Rear yard retaining wall 9-16-2022 12 ITEMS CHECKED ABOVE ARE APPROVED AND WITHOUT DEFICIENCIES. ❑ OBSERVED DEFICIENCIES AND COMMENTS: EXISTING WALL WAS MEASURED AND EVALUATED FOR GEOMETRY & LOCATION OF STRUCTURAL STEEL CALCULATIONS INDICATE WALL IS ADEQUATE AS DESIGNED AND CONSTRUCTED. ❑ REPORT CONTINUED ON ATTACHED PAGES. 12 FINAL STRUCTURAL OBSERVATION REPORT: The structure generally complies with the approved construction documents, and all observed deficiencies were corrected. I declare that the following statements are true to the best of my knowledge: 1. I am the licensed design professional retained by the owner to be in responsible QIAPe"r charge of the structural observation; Qg9 X 2. I, or another licensed design professional whom I have designated above and is under �v my responsible charge, have performed the required site visits at each significant construction stage to verify that the structure is in general conformance with th approved construction documents; t NO. 42265 3. 1 understand that all deficiencies which I have documented must be corrected, prior t6 final acceptance of the structural systems by the City of Newport Beach, Building sr C Division. +r 11-8-2022 STAMP OF STRUCTURAL OBSERVER STRUCTURAL OBSERVATION DOES NOT WAIVE ANY REQUIREMENTS FOR BUILDING INSPECTION BYAUTHORIZED EMPLOYEES OF THE CITY OF NEWPORT BEACH. Farms\Stm=rOObservatioo qon&lnstmctions W. C. HOBBS, CONSULTING ENGINEER 28411 PACHECO MISSION VIEJO, CALIFORNIA 92692 (951) 660-9800 Date: September 27, 2022 Project No: S2215 Adrienne Worley 369 Santa Isabel Avenue Newport Beach, California 92660 Subject: Structural Evaluation of Existing Retaining Wall, Residence at 369 Santa Isabel Avenue, Newport Beach, California 92660 Dear Adrienne, Pursuant to a requirement by the City of Newport Beach, this document has been prepared to evaluate an existing retaining wall constructed as part of rear yard improvements at the subject site. Executive Summary Based on information provided by the current contractor, the wall was constructed within the past year or two by previous contractors employed on the project. Rear yard improvements that have been made in addition to the subject retaining wall include a pool and pool decks at two levels with associated appropriate drainage and drainage devices. The subject retaining wall is located at the rear most part of the property, essentially along the southwestern boundary line. The subject wall actually extends from the southeast property corner approximately 20 feet to the northeast. From that same corner, it also extends 33 feet northwest, where it angles away from the property line approximately 10 feet northeast, then continues to the northwest property boundary. A sketch plat is also included herewith for clarification of subject wall location. The maximum height of retained earth is measured to be 4.3 feet at the southeast property corner. Site Description ` The site consists of a rectangular parcel located at 369 Santa Isabel Avenue in the City of Newport Beach. It is currently occupied by a single family residence, which covers a major central portion of the lot. The remainder of the improvements include the aforementioned pool and decks, and landscapes and hardscapes with appropriate existing drainage. It appears that the parcel is almost completely developed with the l exception of a small low lying periodically wet area in the western most portion of the lot. Adrienne Worely, As -Built Retaining Wall Evaluation Project No: S2215 Field Work Page: 2 Field work consisted of several excavations made by hand at the front of the wall footing and in the backfill area to observe the geometry of the retaining wall elements, including the foundation. Additionally, a metallic sensing device calibrated for ferrous metals was used to determine location of reinforcing steel within the masonry units and concrete footing. Subsequently, this information was used in the structural evaluation of the existing retaining wall to determine if modifications were necessary. Retaining Wall Geometry and Reinforcement Measurements of the existing retaining wall have been made from the excavations and exposed parts of the CMU and Foundations, both on the front of the wall and footing and in the backfill areas. Measurements indicate that the stem of the wall is constructed of 3 courses of 12 inch wide masonry units and the remainder being 8 inch wide masonry units. Excavations also revealed a footing that is roughly 14 inches thick, extending a minimum of 4 inches forward of the face of the wall and 24 inches rearward of the back of the lowest course of 12 inch CMU block (3'-4" total width). Reinforcing steel depth and location was measured in the CMU units as well as a portion of the exposed footing. Reinforcing steel in the CMU units was found at 16 inches on centers vertical and was closer than 24 inches on center horizontal. Reinforcing steel in the portion of the heel exposed was roughly 12 inches on centers and roughly 3" depth below edge of concrete. CONCLUSIONS AND RECOMMENDATIONS Conclusions General Based on the excavations, it appears that the same type (geometry) of retaining wall was use over the entire length, regardless of backfill height. In general, the following conclusions have been made. • Based on observations and measurements, the maximum depth of backfill is in the southeast corner of the wall at 4.3 feet. From the southeast corner, the backfill depth decreases along the length of both property boundaries to depths of 1 foot. W. C. HOBBS, CONSULTING ENGINEER Adrienne Worely, As -Built Retaining Wall Evaluation Project No: S2215 Page: 3 Backfill surfaces have been sloped to drain into appropriate drainage devices, in particular, a catch basin at the northwestern most extent of the wall. This catch basin is connected to a drain pipe that goes through the wall. A burrito type subdrain was observed at the back and base of the retaining walls, consisting of gravel, pipe and geofabric wrap. In the absence of a geotechnical report, pursuant to CBC chapter 18 requirements, r Class 4 type earth materials characteristics were used for the retaining wall structural design evaluation. Structural evaluation of the existing retaining wall for the maximum of 4.3 feet of ( backfill based on the geometry and reinforcement measured indicates that the retaining wall as constructed is adequate by current standards. Please refer to Appendix A for structural calculations. These calculations also infer that walls with less than 4.3 feet of retained earth are adequate. Final Conclusion Based on observations made, measurements made and calculations performed, it is reasonable to expect that the existing retaining wall as constructed and backfilled will perform as expected for its intended use. Recommendations The retaining wall as constructed should be monitored on a regular basis. Care should be taken to make sure that surface waters in the backfill area are properly drained and do not infiltrate into the retaining wall subdrain. If for any reason, the wall does not appear to be performing or functioning as intended, this office should be notified and observe any anomalies pertaining to the rear yard wall so that additional recommendations can be made. C W. C. HOBBS, CONSULTING ENGINEER ( Adrienne Worely, As -Built Retaining Wall Evaluation Page: 4 ( Project No: S2215 (' LIMITATIONS r Our investigation was performed using the degree of care and skill ordinarily exercised, under similar circumstances, by reputable Engineers practicing in this or similar localities. No other warranty, expressed or implied, is made as to the conclusions and professional r conclusions or advice included in this report. The findings of this report are valid as of the present date. However, changes in the conditions of a property can occur with the passage of time, whether due to natural processes or the works of man on this or adjacent properties. In addition, changes in applicable or appropriate standards may occur, whether they result from legislation or the broadening of knowledge. Accordingly, the findings of this report may be invalidated wholly or partially by changes outside our control. Therefore, this report is subject to review and revision as changed conditions are identified. The firm that performed this investigation for this project should be retained to provide testing observation services during construction to maintain continuity of geotechnical interpretation and to check that the recommendations presented herein are implemented or if other improvements are planned. If another firm is selected to perform the testing and observation services during construction operations, that firm should prepare a letter indicating their intent to assume the responsibilities of project engineer of record. Selection of another firm to perform any of the recommended activities or failure to retain the undersigned to perform the recommended activities wholly absolves W. C. Hobbs, Consulting Engineer, the undersigned professional(s), and its assigns from any and all liability arising directly or indirectly from any aspects of this project. W. C. HOBBS, CONSULTING ENGINEER Adrienne Worely, As -Built Retaining Wall Evaluation Page: 5 Project No: S2215 CLOSURE The opportunity to be of service is appreciated. Should questions or comments arise pertaining to this document, or if we may be of further service, please do not hesitate to call our office. Respectfully Submitted, W. C. HOBBS, CONSUL' N0.42W 1 Bill Hobbs, RCE 42265 Civil Engineer Distribution: Addressee (1) (electronic pdf) Attachments: Plat, Wall Location Sketch Plat Appendix A, Retaining Wall Structural Calculations W. C. HOBBS, CONSULTING ENGINEER APPENDIX A W. C. HOBBS, CONSULTING ENGINEER W. C. HOBBS, CONSULTING ENGINEER 28411 PACHECO MISSION VIEJO, CALIFORNIA 92692 951.660.9800 wchobbs@wwdborg Project Title: WORLEY Engineer: WCH Project ID: S2215 Project Descr: RETAINING WALL VERIFICATION Cantilevered Retaltilrla Wall Project File: WORLEY.ec6 DESCRIPTION: REAR YARD WALL AS BUILT Code Reference: Calculations per IBC 2018 1807.3, CBC 2019, ASCE 7-16 Criteria Retained Height = 4.50ft Wall height above soil = 1.50 ft Slope Behind Wall = 0.00 Height of Soil over Toe = 4.00 in Water height over heel = 0.0 ft Surcharge Loads Surcharge Over Heel = 0.0 psf Used To Resist Sliding & Overturning Surcharge Over Toe = 0.0 psf Used for Sliding & Overturning Axial Load Applied to Stem Axial Dead Load = 0.0 Ibs Axial Live Load = 0.0 Ibs Axial Load Eccentricity = 0.0 in Soil Data Allow Soil Bearing = 1,500.0 psf Equivalent Fluid Pressure Method Active Heel Pressure = 35.0 psf/ft Passive Pressure = 150.0 psf/ft Soil Density, Heel = 110.00 pcf Soil Density, Toe = 110.00 pot FootingllSoil Friction = 0.400 Soil height to ignore for passive pressure = 6.00 in Lateral Load Applied to Stem Lateral Load = 0.0 #/ft ...Height to Top = 0.00 ft ...Height to Bottom = 0.00 ft Load Type = Wind (W) (Service Level) Wind on Exposed Stem = 0.0 psf (Strength Level) Aatacent rooting I_oaa Adjacent Footing Load = 0.0 Ibs Footing Width = 0.00 ft Eccentricity = 0.00 in Wall to Fig CL Dist = 0.00 ft Footing Type Spread Footing Base Above/Below Soil = 0.0 ft at Back of Wall Poisson's Ratio = 0.300 W. C. HOBBS, CONSULTING ENGINEER 28411 PACHECO MISSION VIEJO, CALIFORNIA 92692 951.660.9800 wchobbs@wwdborg Cantilevered Retaining Wall DESCRIPTION: REAR YARD WALL AS BUILT Design Summary Wall Stability Ratios Overturning = 4.15 OK Sliding = 1.60 OK Global Stability = 2.72 Total Bearing Load = 1,827 lbs ...resultant am. = 3.03 in Eccentricity withinmiddle third Soil Pressure @ Toe = 261 psf OK Soil Pressure @ Heel = 696 psf OK Allowable = 1,500 psf Soil Pressure Less Than Allowable ACI Factored @ Toe = 365 psi ACI Factored @ Heel = 974 psf Footing Shear @ Toe = 0.4 psi OK Footing Shear @ Heel = 3.3 psi OK Allowable = 82.2 psi Ctnm rnnstructinn Sliding Calcs Lateral Sliding Force = 529.4 lbs less 100% Passive Force - 114.6 lbs less 100% Friction Force =_ 730.8 lbs Added Force Req'd = 0.0 lbs OK ....for 1.5 Stability = 0.0 lbs OK Vertical component of active lateral soil pressure IS considered in the calculation of soil bearing pressures. Load Factors Building Code Dead Load 1.200 Live Load 1.600 Earth, H 1.600 Wind, W 1.600 Seismic, E 1.000 Project Title: WORLEY Engineer: WCH Project ID: S2215 Project Descr: RETAINING WALL VERIFICATION Project File: WORLEY.ec6 VG ENGINEER (0) ENERCALC INC 1983-20; 2nd Bottom Stem OK Design Height Above Fti; it = 2.00 Wall Material Above "Ht" = Masonry Design Method = ASD Thickness = 8.00 Rebar Size = # 4 Rebar Spacing = 32.00 Reber Placed at = Edge Design Data fb/FB+fa/Fa = 0.124 Total Force @ Section Service Level lbs = 109.4 Strength Level lbs = Moment... Actual Service Level ft-#= 91.1 Strength Level ft-#= Moment..... Allowable it-P= 734.5 Shear..... Actual Service Level psi= 1.2 Strength Level psi= Shear..... Allowable psi= 43.6 Anet(Masonry) in2= 91.50 Wall Weight psf= 0.0 Reber Depth 'd' in= 5.25 Masonry Data fm psi= 1,500 Fs psi= 24,000 Solid Grouting = Yes Modular Ratio'n' = 21.48 Equiv. Solid Thick. in = 7.63 Masonry Block Type = Masonry Design Method = ASD Concrete Data Fc psi= Fy psi= Stem OK 0.00 Masonry ASD SD SD 12.00 # 5 16.00 Edge 0.166 354.4 531.6 3,183.7 2.5 43.7 139.50 0.0 9.00 1,500 20,000 Yes 21.48 11.63 W. C. HOBBS, CONSULTING ENGINEER 28411 PACHECO MISSION VIEJO, CALIFORNIA 92692 961.660.9800 wchobbs@wwdborg Project Title: WORLEY Engineer: WCH Project ID: S2215 Project Descr: RETAINING WALL VERIFICATION Cantilevered Retaiftina Wall Project File: WORLEY.ec6 DESCRIPTION: REAR YARD WALL AS BUILT Footing Data Toe Width = 0.33 ft Heel Width = 3.00 Total Footing Width = 3.33 Footing Thickness = 12.00 in Key Width = 0.00 m Key Depth = 0.00 in Key Distance from Toe = 0.00 ft fc = 3,000 psi Fy = 40,000 psi Footing Concrete Density = 150.00 pcf Min. As % = 0.0018 Cover @ Top 3.00 @ Btm = 3.00 in Footing Design Results TOO H€-gt Factored Pressure = 365 974 pat Mu': Upward = 21 1,298 ft-# Mu': Downward = 31 2,683 ft# Mu: Design = -10 OK 1,385 ft# OK phiMn = 2,739 7,702 ft# Actual 1-Way Shear = 0.43 3.32 psi Allow 1-Way Shear = 43.82 82.16 psi Toe Reinforcing = None Spec'd Heel Reinforcing = # 5 @ 12.30 in Key Reinforcing = None Spec'd Footing Torsion, Tu = 0.00 ft-Ibs Footing Allow. Torsion, phi Tu = 0.00 ft-Ibs If torsion exceeds allowable, provide supplemental design for footing torsion. Other Acceptable Sizes & Spacings Toe: phiMn = phi'5'lambda'sgrt(fc)'Sm Heel: #4@ 9.25 in, #5@ 14.35 in, #6@ 20.37 in, #7@ 27.77 in, #8@ 36.57 in, #9@ 46.29 in, #10@ 58.79 in Key: No key defined Min footing T&S reinf Area Min footing T&S reinf Area per foot If one laver of horizontal bars: #4@ 9.26 in #5@ 14.35 in #6@ 20.37 in 0.86 in2 0.26 in2 A If two lavers of horizontal bars: #4@ 18.52 in #5@ 28.70 in #6@ 40.74 in W. C. HOBBS, CONSULTING ENGINEER Project Title: 28411 PACHECO Engineer: MISSION VIEJO, CALIFORNIA 92692 Project ID: 951.660.9800 Project Descr: wchobbs@wwdborg WORLEY WCH S2215 RETAINING WALL VERIFICATION Cantilevered Retaining Wall Project File: WORLEY.eo6 LIC# : KW-06017463, Build:20.22.a.17 W.C. HOBBS CONSULTING ENGINEER (c) ENERCALC INC 19a3-2022 DESCRIPTION: REAR YARD WALL AS BUILT Summary of Overturning & Resisting Forces & Moments .....OVERTURNING..... .....RESISTING..... Force Distance Moment Force Distance Moment Item Ibs ft ft-# Ibs ft ft-# HL Act Pres (ab water tbl) HL Act Pres (be water tbl) Hydrostatic Force Buoyant Force = Surcharge over Heel = Surcharge Over Toe = Adjacent Footing Load = Added Lateral Load _ Load @ Stem Above Soil = 529.4 1.83 Total = 529.4 O.T.M. _ Resisting/Overturning Ratio = 4.15 Vertical Loads used for Soil Pressure = 1,826.9 Ibs 970.5 Soil Over HL (ab. water tbl) 990.0 2.33 2,306.7 Soil Over HL (bet. water tbl) 2.33 2,306.7 Watre Table Sloped Soil Over Heel = Surcharge Over Heel = Adjacent Footing Load = Axial Dead Load on Stem= * Axial Live Load on Stem = Soil Over Toe = 12.1 0.17 2.0 Surcharge Over Toe = Stem Weights) _ Earth @ Stem Transitions= 91.7 1.16 106.6 970.5 Footing Weight = 499.5 1.67 831.7 Key Weight = Vert. Component - 233.7 3.33 778.1 Total = 1,826.9 Ibs R.M.= 4,025.1 • Axial live load NOT included in total displayed, or used for overturning resistance, but is included for soil pressure calculation. Vertical component of active lateral soil pressure IS considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS considered in the calculation of Overturning Resistance. Tilt Horizontal Deflection at Too of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pot Horizontal Defl @ Top of Wall (approximate only) 0.000 in The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe, because the wall would then tend to rotate into the retained soil. W. C. HOBBS, CONSULTING ENGINEER Project Title: 28411 PACHECO Engineer: MISSION VIEJO, CALIFORNIA 92692 Project ID: 951.660.9800 Project Descr: wchobbs@mudborg WORLEY WCH S2215 RETAINING WALL VERIFICATION Cantilevered Retaining Wall Project File: WORLEY.ec6 DESCRIPTION: REAR YARD WALL AS BUILT Rebar Lap & Embedment Lengths Information Stem Design Seament: 2nd Stem Design Height: 2.00 ft above top of footing Calculated Reber Stress, fs = 2978.34 psi Lap Splice length for #4 bar specified in this stem design segment = Development length for #4 bar specified in this stem design segment = Stem Design Segment: Bottom Stem Design Height: 0.00 It above top of footing Calculated Reber Stress, fs = 3339.32 psi Lap Splice length for #5 bar specified in this stem design segment = Development length for #5 bar specified in this stem design segment = Hooked embedment length into footing for #5 bar specified in this stem design segment = As Provided = As Required = 20.00 in 12.00 in 25.00 in 12.00 in 6.00 in 0.2325 in2/ft 0.0394 in2/ft W. C. HOBBS, CONSULTING ENGINEER 28411 PACHECO MISSION VIEJO, CALIFORNIA 92692 951.660.9800 wchobbs@wwdborg Project Title: WORLEY Engineer: WCH Project ID: S2215 Project Descr: RETAINING WALL VERIFICATION Cantilevered Retaining Wail Project File: WORLEY.ec6 DESCRIPTION: REAR YARD WALL AS BUILT 4" 8" w/ #4@ 32" Solid Grout 12" w/ #5@ 16" Solid Grout #5@12.3" @ Heel 3" fi1C:1t 4'_6" m W. C. HOBBS, CONSULTING ENGINEER 28411 PACHECO MISSION VIEJO, CALIFORNIA 92692 951.660.9800 wchobbs@wwdborg Project Title: WORLEY Engineer: WCH Project ID: S2215 Project Descr: RETAINING WALL VERIFICATION Cantilevered Retalnlna Wall Project File: WORLEY.ec6 DESCRIPTION: REAR YARD WALL AS BUILT Pp= 114.58#z 529# N N d d W O CO N Lateral earth pressure due to the soil BELOW water table CC1'-TY 0TV TUEM11-I)ORT BF.AC�I (COI`VIMUN['I Y DEVELOPMENT DEPARTMENT T BUILDING DIVISION �c«oKr� 100 Civic Center I P.O. Box 1768 1 Newport Beach, CA 92658 www.newportbeachca.gov 1 (949) 644-3275 PLAI H REM f CCo)RMW Project 6 ft Retaining wall at rear yard property line with returns. Description: Project Address: 369 Santa Isabel Plan Check No.: OTC Permit App. Date: OTC Plan Check Expires: CY Cut/Fill: Permit Valuation: Adjusted Valuation: Architect/Engineer: Phone: Applicant/Contact: Phone: Plan Check Samir Ghosn, P.E. Phone: (949)644-3277 Engineer: Engineer email: sghosn a@newportbeachca.gov n1st Review: 2"d Review: 3rd Review: 1-10-2017 Italic comments F-1 By Appointment The project plans were reviewed for compliance with the following codes and standards: 2016 CBC; 2016 CPC; 2016 CMC, 2016 CEC, 2016 California Green Building Standards Code (CALGreen),2016 Energy(Title 24); & Chapter 15 of the Newport Beach Municipal Code (NBMC). The code section references are from the 2016 CBC, unless otherwise stated. ® TO EXPEDITE PROJECT APPROVAL: Please provide a written response indicating how and where each comment was resolved on the plans. ® Resubmit all previously reviewed plans, updated plans and supporting documents with each subsequent review. ® AFTER Z' PLAN REVIEW. Please call the plan check engineer listed above to schedule a plan review appointment, to expedite project approval. ® For clarification of any plan review comment, please call the plan check engineer listed above. ® Plan review status is available online at www.neweortbeachca aov. Project status is also available using the interactive voice response system at 949-644-3255, or by speaking with a permit technician at 949-644-3288 during business hours. S. Ghosn, P.E. Obtain Approval from the following dept. A) Planning B) 13uildinq C) Public World PLAN REVIEW COMMENTS Please provide copy of the soil report for the rear retaining wall design criteria. `�' Please provide detail for the pipe drain behind the wall anti AhrnAi iQCati^n rf pol,nt cf diSchai y8. ` The drainage of the pipe drain is not allowed to discharge over adjoining property. Please show an appropriate method of collection and pumping the discharge to the street. Please provide special and periodic inspection as required in compliance with ACI 530-11 quality assurance level B for design category I, II and Ill. For foundation footing # 4 bar counter acting the design moment of the stem as shown in detail 6 n S-1, show development of bar by using a hook at end of bar to develop the bar for tension. or stepped footing detail, show the horizontal lap to be 2 x the vertical step. See marked set S-1. Please delete detail 1 on S-1 for property line condition. No allowance for footing projection beyond the property line. Please label appropriately the applicable details for the wall and the return segments including the stepped footing detail. Provide detail for swale location to collect the sheet flow drainage from the landscaped area. Show method of tie for drain line to the discharge tank or sump pump. Please show and correct graphically the distance from the face of wall to the location of tension steel as 5.25 for 6 inch block and 9 inches for 12 inches block. See the marked set. S. Ghosn, P.E. PHASE II ENGINEERING, INC. P p 141 1 N. BATAVIA 5T., SUITE 208 - 138 JOB NO. I G ORANGE, CA 928G7 (714) 3G3-3585 STRUCTURAL CALCULATIONS FOR G'-O" Hlc3h Retainincg Wall AT Residence 3G9 Santa Isabel Newport Beach, CA FOR / Bob Jones Custom PooI5 * Spas 2595 Gibson 5t. Riverside, CA 92503 DE51GN PER CALIFORNIA BUILDING CODE, 2013 EDITION * GLOBAL GEO- ENGINEERING 5O11-5 REPORT 1313-OG I - I FOUNDATION PRE55URE = 1 500p5f ACTIVE PRE55URE = 34pcf (Non -Expansive Imported Backfill) SEISMIC EARTH PRE55URE = 20pcf PA551VE PRESSURE = 250pcf FRICTION = 0.30 CONCRETE fr' = 2500p5i (De5lcgn Strength) MASONRY fm'= 1 500p5i REINFORCING fy = 40,OOOP51 (Grade 40 or a5 noted) Phase II Engineering, Inc. Title 369 Senta Isabel 1411 N. Batavia St. #208 Job #: Dsgnr: DP Orange, CA 92867 Description.... (714) 363-3685 6' Retaining Wall per Soils Report info@phase2eng.com This Wall in File: c:\Users\Jason\Desktop\Dawn\16-138 ret wall. RPX Page : 1 Date: 22 DEC 2016 RetatnPro (C) 1957-2015, Build 11.15.07.15 License: ►cW-oso618o3. - _ Cantilevered Retaining Wall Code: CBC 2013,ACI 318-11,ACI 530-11 Criteria Retained Height = 6.00 ft Wall height above soil = 0.50 ft Slope Behind Wall = 0.00 Height of Soil over Toe = 0.00 in Water height over heel = 0.0 It f Soil Data Allow Soil Bearing = 1,500.0 psf Equivalent Fluid Pressure Method Active Heel Pressure = 34.0 psf/ft Passive Pressure = 250.0 psf/ft Soil Density, Heel = 110.00 pcf Soil Density, Toe = 0.00 pcf FootingliSoii Friction = 0.300 Soil height to ignore for passive pressure = 18.00 in Surcharge Loads Lateral, Load Applied to Stem Surcharge Over Heel = 0.0 psf Lateral Load = 0.0 #/ft Used To Resist Sliding & Overturning ...Height to Top = 0.00 It Surcharge Over Toe = 0.0 psf ...Height to Bottom = 0.00 ft Used for Sliding & Overturning Load Type = Wind (W) Axial Load Applied to Stem (Service Level) Axial Dead Load = 0.0 Ibs Wind on Exposed Stem = 0.0 psf Axial Live Load = 0.0 lbs (Service Level) Axial Load Eccentricity = 0.0 in Earth Pressure Seismic Load I Method : Inverted Triangular Load at top of Inverted Triangular Distribution ...... (Strength) ii� �% lotina Load Haiaceni rooting Loaa - u.0 ID Footing Width - 0.00 ft Eccentricity = 0.00 in Wail to Ftg CL Dist - 0.00 ft Footing Type Line Load Base Above/Below Soil = at Back of Wail 0.0 ft Poisson's Ratio = 0.300 Total Strength -Level Seismic Load.. , .. = 420.000 Ibs 120.000 psi Total Service -Level Seismic Load..... = 294.000 Ibs Design Summary Stem Construction end Bottom Wall Stability Ratios Design Height Above FtE ft= Stem OK 2.00 Stem OK 0.00 Overturning = 1.79 OK Wall Material Above "Ht" = Masonry Masonry Sliding = 1.65 OK Design Method - ASD ASD Total Bearing Load - 2,363 Ibs ...resultant ecc. = 9.78 in Soil Pressure @ Toe - 1,430 psf OK Soil Pressure @ Heel - 0 psf OK Allowable _ 1,500 psf Soil Pressure Less Than Allowable ACI Factored @ Toe = 2,002 psf ACI Factored @ Heel = 0 psf Footing Shear @ Toe = 22.8 psi OK Footing Shear @ Heel = 8.9 psi OK Allowable = 75.0 psi Sliding Calcs Lateral Sliding Force = 1,127.0lbs less 100% Passive Force = - 1,039.1 ibs less 100% Friction Force = - 708.9 Ibs Added Force Req'd = 0.0 Ibs OK ...,for 1.5 Stability = 0.0 Ibs OK Thickness = 8.00 12.00 Rebar Size = # 4 # 4 Rebar Spacing = 16.00 8.00 Rebar Placed at = Edge Edge Design Data fb/FB + fa/Fa = 0.855 0,661 Total Force @ Section Service Level Ibs = 614.9 1,023.4 Strength Level Ibs = Moment.... Actual Service Level ft-#= 1,139.8 2,766.9 Strength Level ft-# = Moment..... Allowable ft-# = 1,193.2 4,063.6 Vertical component of active lateral soil pressure IS considered in the calculation of soil bearing pressures. Load Factors - Building Code Dead Load Live Load Earth, H Wind, W Cnemir G CBC 2013,AC1 1.200 1.600 1.600 1.000 1 nnn Service Level Strength Level Shear..... Allowable An-et_(Masonry)._ e'lRebar Depth 'd' F t'm Fs Solid Grouting Modular Ratio 'n' Wall Weight Short Term Factor Equiv. Solid Thick. Masonry Block Type Masonry Design Method Concrete Data fc Fy psi = 6.7 7.3 psi = psi = 44.8 45.1 psi = 1,500 psi= 20,000 - Yes = 21.48 psf = 84.0 = 1.000 in = 7.60 = Normal Weight = ASD psi = psi = 1,600 20,000 Yes 21.48 133.0 1.000 11.60 1va-CaI S. It C 1. P Phase 11 Engineering, Inc. Title 369 Santa Isabel Page : 2 1411 N. Batavia St. #208 Job #: Dsgnr: DP Date: 22 DEC 2016 Orange, CA 92867 Description.... �- -� (714) 363-3585 6' Retaining Wall per Soils Report Linfo@phase2eng.com This Wall in File: c:\Users\Jason\Desktop\Dawn\l6-138 ret wall. RPX RetalnPro (c)1987-2016, Build 11.16.07.16 License: KW-06061803_ Cantilevered Retaining Wall Code: CBC 2013,ACI 318-11,ACI 530-11 Footing Dimensions & Strengths Footing Design Results Toe Width = 1.83 ft` Toe Heel Heel Width = 2.00 Factored Pressure = 2,002 0 psf Total Footing Width = 3.83 Mu': Upward - 2,741 11 ft-# Footing Thickness = 12.00 in Mu': Downward = 385 729 ft-# Mu: Design = 2,356 718 it-# Key Width .00 in Actual 1-Way Shear = 22.76 8.87 psi Key Depth - 27.00 in Allow 1-Way Shear = 75.00 75.00 psi Key Distance from Toe - 1.83 ft Toe Reinforcing = # 4 @ 8.00 in fc = 2,500 psi Fy = 40,000 psi Heel Reinforcing = # 4 @ 8.00 in Footing Concrete Density = 150.00 pcf Key Reinforcing = # 4 @ 8.00 in Min. As % = 0.0018 Other Acceptable Sizes & Spacings Cover @ Top 3.00 @ Btm = 3.00 in Toe: Not req'd: Mu < phi*5*lambda*sgrt(fc)*Sm Heel: Not req'd: Mu < phi*5*lambda*sgrt(fc)*Sm Key: #4@ 9.26 in, #5@ 14.35 in, #6@ 18 in, #7@ 18 in, #8@ 18 Min footing T&S reinf Area 0.99 in2 Min footing T&S reinf Area per foot 0.26 in2 A If one layer of horizontal bars: If two layers of horizontal bars: #4@ 9.26 in #4@ 18.52 in #5@ 14.35 in #5@ 28.70 in #6@ 20.37 in #6@ 40.74 in Surnrna ' of Overturnin &_Resisting Forces & Moments .....OVERTURNING........RESISTING..... 'Moment Force Distance Force Distance Moment Item Ibs It ft-# Ibs ft it-# Heel Active Pressure = 833.0 2.33 1,943.7 Soil Over Heel = 660.0 3.33 2,199.8 Surcharge over Heel = Sloped Soil Over Heel - Surcharge Over Toe = Surcharge Over Heel = Adjacent Footing Load = Adjacent Footing Load = Added Lateral Load - Axial Dead Load on Stem= Load @ Stem Above Soil = * Axial Live Load on Stem = Seismic Earth Load = 294.0 4.67 1,372.0 Soil Over Toe - = Surcharge Over Toe - Total 1,127.0 A.T.M. 3,315.7 Stem Weights) = 644.0 2.24 1,439.5 Earth @ Stem Transitions= 146.7 2.67 391.1 _ - Footing Weighl - 575.0 1.92 1,101.9 Resisting/Overturning Ratio - 1.79 Key Weight = 337.5 2.33 787.4 Vertical Loads used for Soil Pressure = 2,363.1 Ibs Vert. Component - 3.83 Total = 2,363.1 lbs R.M.= 5,919.6 If seismic is included, the OTM and sliding ratios * Axial live load NOT included in total displayed or used for overturning be 1.1 per section 1807.2.3 of IBC 2009 or IBC 201 resistance, but is included for soil pressure calculation. Vertical component of active lateral soil pressure IS NOT considered In the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS considered in the calculation of Overturning Resistance. Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Dell @ Top of Wall (approximate only) 0.067 in The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe, because the wall would then tend to rotate into the retained soil. P Phase II Engineering, Inc. Title 369 Spnta Isabel Page 1411 N. Batavia St. #208 Job # : Dsgnr: DP Date: 4 JAN 2017 Orange, CA 92867 Description.... (714) 363-3585 6' Retaining Wall with Inverted Footing per Soils Report -- info@phase2eng.com This Wail in File: c:\users\ anon\desktop\dawn\16-138 ret wall. rpx RetainPro (c) 1987-2016, Build 11.16.07.16 License: KW-0061803. - . Cantilevered Retaining Wall Code: CBC 2013,ACI 318-11,ACi 530-11 Criteria Retained Height = 6.00It Wall height above soil = 0.50 ft Slope Behind Wall - 0.00 Height of Soil over Toe = 0.00 in Water height over heel = 0.0 ft Soil Data Allow Soil Bearing = 1,500.0 psf Equivalent Fluid Pressure Method Active Heel Pressure = 34.0 psf/ft Passive Pressure = 250.0 psf/ft Soil Density, Heel = 110,00 pcf Soil Density, Toe = 0.00 pcf FootingIlSoil Friction - 0.300 Soil height to ignore for passive pressure = 18.00 in Surcharge Loads Lateral Load Applied to Stem Surcharge Over Heel = 0.0 psf Lateral Load = 0.0 #/ft Used To Resist Sliding & Overturning ...Height to Top = 0.00 It Surcharge Over Toe = 0.0 psf ...Height to Bottom 0.00 It Used for Sliding & Overturning Load Type = Wind (W) Axial Load Applied to Stem (Service Level) Axial Dead Load = 0.0 Ibs Wind on Exposed Stem = 0.0 psf Axial Live Load = 0.0 Ibs (Service Level) Axial Load Eccentricity = 0.0 in Earth Pressure Seismic Load I ENNIMMME Method : Inverted Triangular Load at top of Inverted Triangular Distribution ... , . . (Strength) t Footina Load Naiacent rooting r.oaa = u.0 io Footing Width - 0.00 It Eccentricity = 0.00 in Wail to Ftg CL Dist = 0.00 ft Footing Type Line Load Base Above/Below Soil _ 0.0 ft at Back of Wall Poisson's Ratio = 0.300 Total Strength -Level Seismic Load..... - 420.000 Ibs 120.000 psi Total Service -Level Seismic Load..... = 294.000 Ibs Design Summary Stem Construction Wall Stability Ratios Design Height Above Ftg ft = Overturning = 4.07 OK Wail Material Above "Ht" _ Sliding = 1.51 OK Design Method = Total Bearing Load = 4,815 Ibs ...resultant ecc. = 8.12 in Soil Pressure @ Toe - 1,489 psf OK Soil Pressure @ Heel = 236 psf OK Allowable = 1,500 psf Soil Pressure Less Than Allowable ACI Factored @ Toe = 2,085 psf ACI Factored @ Heel - 330 psf Footing Shear @ Toe = 0.0 psi OK Footing Shear @ Heel = 3.5 psi OK Allowable = 75.0 psi Sliding Calcs Lateral Sliding Force = 1,127.0 Ibs less 100% Passive Force = - 261.3 Ibs less 100% Friction Force = - 1,444.6 Ibs Added Force Req'd = 0.0 Ibs OK ....for 1.5 Stability = 0.0 Ibs OK Thickness = Rebar Size = Rebar Spacing = Reber Placed at = Design Data fb/FB + fa/Fa = Total Force @ Section Service Level Ibs = Strength Level Ibs = Moment.... Actual Service Level ft-# = Strength Level ft-# = Moment..... Allowable ft-# = Vertical component of active lateral soil pressure IS considered in the calculation of soil bearing pressures. Load Factors - Building Code Dead Load Live Load Earth, H Wind, W Seismic, E CBC 2013,ACI 1.200 1.600 1.600 1.000 1.000 Service Level Strength Level Shear..... Allowable Anet (Masonry) Rebar Depth 'd' Masonry Data fm Fs Solid Grouting Modular Ratio'n' Wall Weight Short Term Factor Equiv. Solid Thick. Masonry Block Type Masonry Design Method Concrete Data fc Fy psi = psi = psi = in2 = in = 2nd Stem OK 2.00 Masonry ASD 8.00 # 4 16.00 Edge Bottom Stem OK 0.00 Masonry ASD 12.00 # 4 8.00 Edge 0.956 0.681 614.9 1,023.4 1,139.8 2,766.9 1,193.2 4,063.6 6.7 7.3 44.8 45.1 91.50 139.50 5.26 9.00 psi= 1,500 1,500 psi = 20,000 20,000 = Yes Yes = 21,48 21.48 psf = 84.0 133.0 = 1.000 1.000 in = 7.60 11.60 = Normal Weight = ASD psi = PSI = P Phase II Engineering, Inc. Title 369 Spnta Isabel Page 1411 N. Batavia St. #208 Job #: Dsgnr: DP Date: 4 JAN 2017 Orange, CA 92867 Description.... (714) 363-3685 6' Retaining Wall with Inverted Footing per Soils Report info@phase2eng.com This Wall in File: c:\users\jason\desktop\dawM16-138 ret wail.rpx RetainPro (c) 1987-2016, Build 11.16.07.16 License: KW-06061803_ _ _ Cantilevered Retaining Wall Code: CBC 2013,ACI 318-11,AC1 530-11 Footing Dimensions & Strengths Footing Design Results Toe Width = 0.00 ft, Toe Heel Heel Width = 5.58 Factored Pressure - 2,085 330 psf Total Footing Width = 5.58 Mu': Upward = 0 8,508 ft-# Footing Thickness = 12.00 in Mu': Downward = 0 11,322 ft-# Mu: Design = 0 2,813 ft-# Key Width = 12.00 in Actual 1-Way Shear = 0.00 3.52 psi Key Depth = 13.00 in Allow 1-Way Shear = 0.00 75.00 psi Key Distance from Toe = 4.58 ft Toe Reinforcing = # 4 @ 8.00 in Pc = 2,500 psi Fy = 40,000 psi Heel Reinforcing = # 4 @ 8.00 in Footing Concrete Density = 150.00 pcf Key Reinforcing = # 4 @ 8.00 in Min. As % = 0.0018 Other Acceptable Sizes & Spacings Cover @ Top 3.00 @ Btm.= 3.00 in Toe: Not req'd: Mu < phi*5*lambda*sgrt(fc)*Sm Heel: #4@ 9.26 in, #5@ 14.35 in, #6@ 20.37 in, #7@ 27.78 in, #8@ 36.57 in, #9@ 46 Key: #4@ 9.26 in, #5@ 14.35 in, #6@ 18 in, #7@ 18 in, #8@ 18 Min footing T&S reinf Area 1.45 in2 Min footing T&S reinf Area per foot 0.26 in2 A If one layer of horizontal bars: If two layers of horizontal bars: #4@ 9.26 in #4@ 18.52 in #5@ 14.35 in #5@ 28.70 in #6@ 20.37 in #6@ 40.74 in Summaof of Overturning & Resisting Forces & Moments .....OVERTURNING..... .....RESISTING..... Force Distance Moment Force Distance Moment Item Ibs ft ft-# Ibs ft ft-# Heel Active Pressure = 833.0 2.33 1,943.7 Soil Over Heel = 3,024.8 3.29 9,956.1 Surcharge over Heel = Sloped Soil Over Heel = Surcharge Over Toe - Surcharge Over Heel = Adjacent Footing Load - Adjacent Footing Load = Added Lateral Load = Axial Dead Load on Stem = Load @ Stem Above Soil = * Axial Live Load on Stem = Seismic Earth Load = 294.0 4.67 1,372.0 Soil Over Toe = = Surcharge Over Toe = Total 1,127.0 O.T.M. 3,315.7 Stem Weight(s) = 644.0 0.40 259.0 Earth @ Stem Transitions = 146.7 0.83 122.2 - - Footing Weight = 837.5 2.79 2,337.7 Resisting/Overturning Ratio = 4.07 Key Weight - 162.5 5.08 826.0 Vertical Loads used for Soil Pressure = 4,815.4 Ibs Vert. Component = 5,58 Total = 4,815.4 Ibs R.M.= 13,501.0 If seismic is included, the OTM and sliding ratios * Axial live load NOT included in total displayed or used for overturning be 1.1 per section 1807.2.3 of IBC 2009 or IBC 201 resistance, but is included for soil pressure calculation. Vertical component of active lateral soil pressure IS NOT considered in the calculation of Sliding Resistance. Vertical component of active lateral soil pressure IS considered in the calculation of Overturning Resistance. Tilt Horizontal Deflection at Top of Wall due to settlement of soil (Deflection due to wall bending not considered) Soil Spring Reaction Modulus 250.0 pci Horizontal Dell @ Top of Wall (approximate only) 0.048 in The above calculation is not valid if the heel soil bearing pressure exceeds that of the toe, because the wall would then tend to rotate into the retained soil.