HomeMy WebLinkAboutPA2022-0309_20230207_Landscape PlansHARDSCAPE LEGEND 1.Raised Planter Wall to be Smooth Stucco with a Brick Cap 2.4” x 4” Blonde Cobble Driveway a. Grout Color: TBD b. Grout Spacing: TBD 3.4' Tall Gate and Fence, See Sheet L-3 '6' Tall Gate and Fence Elevation' 4.Trash Location 5.Smooth Sand Finish Colored Concrete (Top Cast #3), Davis 'Miami Buff' 6.A/C Location 7.'X' Pattern Vines to be Wires to Wall, Refer to Inspiration Image 8.4' Tall Retaining Wall to be Finished in Smooth Stucco, Color: TBD 9.Smooth Sand Finish Colored Concrete (Top Cast #3), Davis 'Miami Buff' Steps 10.18" x 36" Limestone Tiles in a Running Bond Pattern: a. Color: TBD b. Grout Spacing TBD c. Grout Color TBD 11.38” Tall Small BBQ Counter, See Sheet L-3 'Small BBQ Counter Elevation' 12.8” Wide Double Border with 2” x 8” Faletti Tiles a. Color: TBD b. Grout Spacing TBD c. Grout Color TBD 13.2” x 8” Faletti Tiles in a Herringbone Pattern a. Color: TBD b. Grout Spacing TBD c. Grout Color TBD 14.72” Dia. Table with (7x) 20” x 20” Dining Chairs, Designer to Source 15.(4x) 20” Dia. Pot with Plant Material, Ref. to Sheet L-2, to have Irrigation and Drainage 16.Tiger Turf Pet Turf with Dedicated Irrigation and Draingage 17.8” Wide Single Border with 2” x 8” Faletti Tiles a. Color: TBD b. Grout Spacing TBD c. Grout Color TBD 18.24” Tall Wood Fence to Match Side Gates 19.(2x) 36" x 84" Sofa & (1x) 36" x 60" Coffee Table, Designer to Source 20.Pool Cover Vault Location 21.Bio-Retention Basin (Per Civil Plans) 22.Random Lompoc Steppers, TBD 23.(2x) 7' Long Chaise Lounge Chairs with 18” Dia. Side table and 7' Wide Umbrella, Designer to Source 24.2” Limestone Treads & Risers a. Color: TBD b. Grout Spacing TBD c. Grout Color TBD 25.38” Tall Large BBQ Counter, See Sheet L-3 'Large BBQ Counter Elevation' 26.(10x) 20” x 20” Dining Chairs with (1x) 36” x 120” Dining Table, Designer to Source 27.Pool Equipment Location 28.6' Tall Wood Fence to Block Pool Equipment Enclosure 29.Pool Toys and Towel Storage Box 30.(1x) 36” x 84” Sofa with (4x) 36” x 36” Lounge Chairs, Designer to Source 31.4” Green Seam with Live Plant Material 32.5' x 5' x 18” Tall Fire Pit, See Sheet L-3 'Fire Pit Elevation' 33.7' Wide Dia. Umbrella with and Umbrella Hole in Baja Shelf 34.18” x 36” x 2” thick Limestone Coping a. Color: TBD b. Grout Spacing TBD c. Grout Color TBD 35.New 41'-7” x 15' Pool with 8' x 8' Integrated Spa & Baja Shelf a. Spa Plaster TBD b. Spa Waterline Tile TBD c. Grout Spacing & Color TBD 36. 6' Tall Wood Double Gate to Match 4' Gate Design with Pool Safe Self Close and Self Latching Hardware 37. (2x) 18” Dia. Pot with Plant Material, Ref. to Sheet L-2, to have Irrigation and Drainage 38. 4" Green Seam with Artificial Turf 39. 38" Gravel Chips; Color: TBD 40. Wood Paneled Fence with Vines attached on Horizontal Wires 41. Existing Tree to Remain and Protect in Place A.Contractor shall examine the site of proposed work noting existing conditions and proposed work as shown on the plans. Notify landscape designer of discrepancies B.Contractor shall stake proposed work prior to construction for review by landscape designer C.Protect existing utilities, paving and structures from damage. Trenching adjacent to existing tree drip lines to be done by hand to avoid root damage D.Construction and installation of all landscape items shall be according to State, County, and Local codes, Ordinances and up to CAL_OSHA safety orders regarding performance of work E.Contractor to obtain required permits and comply with applicable codes F.All Concrete edges to be 1/8" trowel G.All Stucco edges to be 1/8" trowel H.Contractor is responsible for damage to underground utilities and shall replace or repair same required at contractors expense I.Contractor shall assemble material samples including: flagstone, gravel, DG, stains, Stucco, etc. for review by owner and landscape designer prior to construction J.coordinate electrical, low voltage, and irrigation conduit sleeves prior to installation of new pavement. K.Contractor to coordinate work with other trades L.Verify grades and elevations in field and notify landscape design of discrepancies M.Contractor to review site for proper drainage and report apparent problems to landscape designer N.Contractor to verify location of any surface drains in concrete surface prior to pour for location verification by owner and landscape designer O.Contractor shall install this project utilizing the landscape industries B.M.P. Best Management Practices P.Contractor to provide direct drainage, low voltage, and irrigation to all pots Q.Contractor to verify proper soil preparation specific to project climate, native soil, site conditions. R.Contractor shall use Netafim drip irrigation for all planters and pots. S.Hardscape Contractor to install and coordinate built in low voltage lighting mounting hardware and sleeves. For example, step lights, in ground lighting, wall lights etc. T.CONTRACTOR TO REVIEW, SIGN, AND APPROVE GARDEN STUDIO'S DESIGN/CONSTRUCTION NOTEBOOK AND AGREES TO BUILD PER THE SPECIFICATIONS IN THE NOTEBOOK CONSTRUCTION NOTES FIL T E R PUMP PUMP HE A T E R 2 2 60x108 1 1 37.5" x 33.5" 37 . 5 " x 33 . 5 " GB GB GB GB GB GB GB GB GB GB GB GB GB GB GB GB GB BS1 BS1 BS1 BS1 BS1 BS1 BS1BS1 BS1BS1 BS1 BS1 BS1 BS1 BS1 BS1 BS1 BS1 P P P P P P P P P GB P P P P P P P P P P RI RI RI RI RI RIRIRI RI RI RI BG BG BG BGBGBG BG BG BG BG BG BG BG BG BG BG BG BG BG BG BG BG BG1 BG1 BG1 BG1 BG1 BG1BG1 BG1 BG1 BG1 BG1 BG1BG1 BG1 BG1 BG1 BG1 BG1 PH PH PH PH PH PH PH PH PH PH PH PH PH C1 C1 C1 C1 C1 C1 C1 C1 C1 C1C1C1 C1 C1 C1 C1 C1 C1 C1 SJ SJ SJSJ SJ O O O O O O O O O O O O O O O PC PC PC PC PC PC PC PC PCPC PCPC SJ2 SJ2 SJ2 SJ2 SJ2 SJ2 SJ2 SJ2 SJ2 SJ2 SJ 2 SJ 2 BG RI RI RI PC BG1 SJ2 SJ2 SJ2 SJ2 SJ2 SJ2 SJ2 SJ2 OP C1C1C1 C1 C1 C1 BG C1 PH PC BG1 C1 C1 BG1 SJ2 RI RI LT LT LT LT LT LT LT BG1 LT LT LT LT LT LT LT LT LT LT PH PH PBG1 PC C1 C1 LTLTLTLTSJ2SJ2SJ2SJ2SJ2 P BG1 BGBG BG BG O BS1 C1C1GBBG SJ P PC BS1 O C1BG BG P GB BG1 O SJ2 SJ2 SJ2 SJ2 SJ2 SJ2 SJ2 SJ2 41'-7" 6' 1' 8' 8' 15 ' M A R I N E R S D R I V E 6' S I D E SE T B A C K 6' FRONT SETBACK 6' S I D E SE T B A C K 10' REAR S E T B A C K (DEVELO P M E N T A R E A ' C ' ) 25' REAR S E T B A C K F R O M T . O . B L U F F 25' REAR SETBACK FROM T.O. BLUFF 10' REAR SETBACK (DEVELOPMENT AREA 'C') 15' REAR SETBACK (DEVELOPMENT AREA 'B') 15' REAR S E T B A C K (DEVEL O P M E N T A R E A ' B ' ) L-1 Hardscape Plan Contractor to Field Verify All Measurements and Confirm Details to Provide Accurate Bid 2732 East Coast Highway, Suite A Corona Del Mar, CA 92625 949.673.5450 Drawn By:KM Sheet: A R D E N S T U D I O D E S I G N G HA W K E R E S I D E N C E 10 0 7 M a r i n e r s D r i v e , N e w p o r t B e a c h , C A 9 2 6 6 0 01.09.2023 11.15.2022 12.12.2022 - Initial Meeting Date: Revisions: APN: 117-663-02 PM:MP Contact Email: monica@gardenstudiodesign.com SCALE: 1/8" =1'-0" 0'2'4'8'16' 1 2 3 4 5 6 7 9 10 11 12 13 14 15 8 7 22 23 24 25 28 27 38 30 20 33 17 1317 24 26 8 32 36 33 1 18 30 29 16 8 18 3 37 38 38 38 38 31 40 32 31 17 34 35 21 39 39 21 41 SizeTrees Quantity Plant Legend: Lagerstroeia indiXa Ë uauriei ± "atXhez± Standard "atXhez Cree !yrtle ¾¹ª boË G Sš P / G Gš PH Cš % PC / iXus nitida ±Standard± ndian Laurel ig Tree šv gal¢ %lea euroaea ±!ulti± %live Tree xmª oË Shrubs :estringia urutiXosa ±Grey o˱ Êaru Coast /oseary v gal¢ Perovs‰ia atriliXiuolia ± lue Sire± lue Sire /ussian Sage v gal¢ Pittosoru tenuiuoliu ±Golu all± Golu all Pittosoruv gal¢ /osa s¢ ±Xeberg± :hite Xeberg /ose v gal¢ uËus iXrohylla ®Green eauty¯ Globe Green eauty oËÊood Globe šmª dia¢ uËus iXrohylla ®Green eauty¯ Globe Green eauty oËÊood Globe Áxª dia¢ outeloua graXilis ± londe #bition± londe #bition lue Graa Grass v gal¢ M Áxª %¢C¢ Crassula arboresXens s¢ undulatiuolia lue :aves ade Plant š gal¢ Hydrangea §uerXiuolia ±Pee :ee± Pee :ee Hydrangea v gal¢ %lea euroaea ±!ontra± Little %llie Êaru %live v gal¢ Pittosoru Xrassiuoliu ±CoaXtu± Êaru aro v gal¢ /osa ®Xeberg¯ Clibing Xeberg Clibing /ose šv gal¢ TraXheloseru ˆasinoides ®Sta‰ed¯ Star asine šv gal¢S STraXheloseru ˆasinoides Star asine v gal¢ Vines x ¹ x Ám Á¹ ¾Á Á¾ vx ¾‘ Áx¸ ¾š Á¸ Á¾ Áv ¾ Áš š¸ Ground Covers Viola hederaXea #ustralian Violet irt lats x Ëisting Tree Size Quantity Size Quantity Size Quantity Pyrus ‰aÊa‰aii vergreen Pear ¾¹ª oË Á Pots Size Quantity %lea euroaea ±Standard± %live Tree :ith Viola at the base šv gal¢x irt lat š Prostanthera ovaliuolia ±Variegata± Variegated !int ush v gal¢Á Sesleria autunalis #utun !oor Grass š gal¢x Hedges Ligustru ˆaoniXu ±TeËanu± Sta‰ed :aË Leau Privet šv gal¢LT ÁÁ Size Quantity Coast ou Caliuornia :ilduloÊer !iË Larner Seeds Seed Á bags !agnolia grandiulora ±Little Ge± Standard Little Ge Êaru Southern !agnolia ¾¹ª oË Á ! # /  "  / S  /  V  ¹± S    S T # C  ¹± /%"T ST #C ¹± S    S T # C  šÒ± /# / S  T # C  ŸVL % P !  " T # /  # ± C ±   Áv± /#/ S  T # C   / % ! T ¢ % ¢ L 4   Áv± /#/ ST #C /%! T¢%¢ L4 šÒ± /#/ ST #C ŸVL%P!"T #/# ±C±  šv± /#/ ST #C ŸVL%P!"T #/# ± ±  šv± /#/ S  T # C  ŸVL% P !  " T # /  # ± ±   L T  / P4!P P4!P H # T  / 2 2 60x108 1 1 ¾¸¢vªË ¾¾¢vª ¾¸ ¢ v ª Ë ¾¾ ¢ v ª G G G G G G G G G G G G G G G G G Sš Sš Sš Sš Sš Sš Sš Sš Sš Sš Sš Sš Sš Sš Sš Sš Sš Sš P P P P P P P P P G P P P P P P P P P P / / // / /// / // G G G G G G G G G G G G G G G G G G G G G G Gš Gš Gš Gš Gš Gš Gš Gš Gš Gš Gš Gš Gš Gš Gš Gš Gš GšPH PH PH PH PH PH PH PH PH PH PH PH PH Cš Cš Cš Cš Cš Cš Cš Cš Cš CšCšCš CšCš Cš Cš CšCšCš S S SS S % % % % % % % % % % % % % % % PC PC PC PC PC PC PC PC PCPC PCPC SÁ SÁ SÁ SÁ SÁ SÁ SÁ SÁ SÁ SÁ S Á S Á G / / / PC Gš SÁ SÁ SÁ SÁ SÁ SÁ SÁ SÁ %P CšCšCš Cš Cš Cš G Cš PH PC GšCš Cš Gš SÁ / / LT LT LT LT LT LT LT GšLT LT LT LT LT LT LT LT LT LT PH PH P Gš PC Cš Cš LTLTLTLTSÁ SÁ SÁ SÁ SÁ P Gš G G G G % Sš CšCšG G S P PC Sš % Cš G G P G Gš% SÁ SÁ SÁ SÁ SÁ SÁ SÁ SÁ L‚Á Planting Plan ContraXtor to ield Veriuy #ll !easureents and Conuir etails to Provide #XXurate id Á¸¾Á ast Coast HighÊay^ Suite # Corona el !ar^ C# ‘Á¹Áv ‘x‘¢¹¸¾¢vxvÒ raÊn y:! Sheet: # /"S T 4   %  S G " G H# :   /  S    " C  šÒ Ò ¸ ! a r i n e r s  r i v e ^ " e Ê  o r t e a X h ^ C # ‘ Á ¹ ¹ Ò Òš¢Ò‘¢ÁÒÁ¾ šš¢šv¢ÁÒÁÁ šÁ¢šÁ¢ÁÒÁÁ ‚ nitial !eeting ate: /evisions: #P": šš¸‚¹¹¾‚ÒÁ P!:!P ContaXt ail: oniXaMgardenstudiodesign¢Xo SC#L: šºmª qš±‚Òª Ò±Á±x±m±š¹± L-3 Elevations Contractor to Field Verify All Measurements and Confirm Details to Provide Accurate Bid 2732 East Coast Highway, Suite A Corona Del Mar, CA 92625 949.673.5450 Drawn By:KM Sheet: A R D E N S T U D I O D E S I G N G HA W K E R E S I D E N C E 10 0 7 M a r i n e r s D r i v e , N e w p o r t B e a c h , C A 9 2 6 6 0 01.09.2023 11.15.2022 12.12.2022 - Initial Meeting Date: Revisions: APN: 117-663-02 PM:MP Contact Email: monica@gardenstudiodesign.com 0'1'2'4' SCALE: 1/2" =1'-0" Fire Pit Elevation Scale: 12" = 1' 1.Brick Cap: a. Antiqued Blonde Ochre Blend Brick 2.Mixed Fireball Set 'Charcoal' 3.Antiqued Blonde Ochre Blend Brick Face 4.Green Seam 5.Finished Grade Legend1234 1' - 6 " 5 Side Gate & Fence Elevation Scale: 12" = 1' 1.Stain Grade Wood Gate, 3" Border & 6" Vertical Wood Planks, Color TBD 2.Stain Grade Wood Fence,3" Border & 6" Vertical Wood Planks, Color TBD 3.Emtek 'Rectangular Helios Key in Leverset with Keypad' Gate Lever with Latch and Strike Plate 4.(3x) Emtek 4" x 4" x 14" Heavy Duty Ball Bearing Hinge 5.Finish Surface Legend 6' 2 21345 Courtyard BBQ Elevation Scale: 12" = 1' 1.3.5" Thick Polished Concrete, Davis 'Miami Buff' Countertop with 1/8" Trowel Edge Detail on all Corners 2.Used Brick Veneer with White Cement Slurry 3.36” Professional Built-In Grill with All Trident Infrared Burners and Rotisserie (L36ATR-NG) 4.36" Ventana Door Drawer Combination (LSA36-4) 5.20" Ventana Outdoor Trash and Recycle Center (L20TR-4) 6.15" Scotsman Nugget Ice Machine (SCN60PA-1SS) 7.Countertop Pizza Over Forno Venetzia Pronto (FVP200) 8.24" Ventana Access Door- Hinge Right (LDR24R-4) 9.N/A 10.Finished Grade Legend 3' - 2 " 3 104176852 1.36” Professional Built-In Grill with All Trident Infrared Burners and Rotisserie (L36ATR-NG) 2.36" Ventana Access Doors (LDR36T-4) 3.3.5" Thick Polished Concrete, Davis 'Miami Buff' Countertop with 18" Trowel Edge Detail on all Corners 4.20" Ventana Outdoor Trash and Recycle Center (L20TR-4) 5.Finished Grade Legend 3'-2" 1 Rear Yard BBQ Elevation Scale: 12" = 1' 2 3 54 1.2" Thick Limestone Treads; 'Los Olivos' Tumbled Edge 2.2" Thick Limestone Cap; 'Los Olivos' Tumbled Edge 3.Used Brick Veneer with White Cement Slurry 4.4" Green Seam 5.Finish Grade 6.Pool Beyond Legend Raised Pool Elevation Scale: 1 2" = 1' 1 2 3 4 1' 5 6 GB GB GB GB GB GB GB GB GB GB GB GB GB GB GB GB GB BS1 BS1 BS1 BS1 BS1 BS1 BS1BS1 BS1BS1 BS1 BS1 BS1 BS1 BS1 BS1 BS1 BS1 P P P P P P P P P GB P P P P P P P P P P RI RI RI RI RI RIRIRI RI RI RI BG BG BG BGBGBG BG BG BG BG BG BG BG BG BG BG BG BG BG BG BG BG BG1 BG1 BG1 BG1 BG1 BG1BG1 BG1 BG1 BG1 BG1 BG1BG1 BG1 BG1 BG1 BG1 BG1 PH PH PH PH PH PH PH PH PH PH PH PH PH C1 C1 C1 C1 C1 C1 C1 C1 C1 C1C1C1 C1 C1 C1 C1 C1 C1 C1 SJ SJ SJSJ SJ O O O O O O O O O O O O O O O PC PC PC PC PC PC PC PC PCPC PCPC SJ2 SJ2 SJ2 SJ2 SJ2 SJ2 SJ2 SJ2 SJ2 SJ2 SJ 2 SJ 2 BG RI RI RI PC BG1 SJ2 SJ2 SJ2 SJ2 SJ2 SJ2 SJ2 SJ2 OP C1C1C1 C1 C1 C1 BG C1 PH PC BG1 C1 C1 BG1 SJ2 RI RI LT LT LT LT LT LT LT BG1 LT LT LT LT LT LT LT LT LT LT PH PH PBG1 PC C1 C1 LTLTLTLTSJ2SJ2SJ2SJ2SJ2 P BG1 BGBG BGBG O BS1 C1C1GBBG SJ P PC BS1 O C1BG BG P GB BG1 O SJ2 SJ2 SJ2 SJ2 SJ2 SJ2 SJ2 SJ2 M A R I N E R S D R I V E 6' S I D E SE T B A C K 6' FRONT SETBACK 6' S I D E SE T B A C K 10' REA R S E T B A C K (DEVEL O P M E N T A R E A ' C ' ) 25' REA R S E T B A C K F R O M T . O . B L U F F 25' REAR SETBACK FROM T.O. BLUFF 10' REAR SETBACK (DEVELOPMENT AREA 'C') 15' REAR SETBACK (DEVELOPMENT AREA 'B') 15' REAR S E T B A C K (DEVELO P M E N T A R E A ' B ' ) FIL T E R PUMP PUMP HE A T E R 2 2 60x108 1 1 37.5"x 33.5" 37 . 5 " x 33 . 5 " Lighting Legend: SymOol Description Product “Finish Type .ty Path Lights GSD-14-1-MBR Matte Bronze 12v LED 66 Regular Uplights GSD-11-1-MBR 49 Small Uplights GSD-11-2-MBR Hanging Lights GSD-16-1-MBR Step Lights GSD-15-1/GSD-15-2-MBR GSD-15-7 Stainless Steel Pool/Lights IntelliBrite 5g Silver Spa Lights IntelliBrite 5g Step Lights (Treads) Matte Bronze Matte Bronze Matte Bronze Matte Bronze Silver 12v LED 12v LED 12v LED 12v LED 12v LED 12v LED 12v LED 19 16 3 10 1 1 L-4 Lighting Plan Contractor to Field Verify All Measurements and Confirm Details to Provide Accurate Bid 2732 East Coast Highway, Suite A Corona Del Mar, CA 92625 949.673.5450 Drawn By:KM Sheet: AR D E N S T U D I O D E S I G N G HA W K E R E S I D E N C E 10 0 7 M a r i n e r s D r i v e , N e w p o r t B e a c h , C A 9 2 6 6 0 01.09.2023 11.15.2022 12.12.2022 - Initial Meeting Date: Revisions: APN: 117-663-02 PM:MP Contact Email: monica@gardenstudiodesign.com SCALE: 1/8" =1'-0" 0'2'4'8'16' SLO-CLOSE SERIES BALL VALVE. SIZE per LINE A IRRIGATION CONTRACTOR TO VERIFY CONTROLLER LOCATION. POWER SUPPLY CONNECTION TO THE IRRIGATION CONTROLLER SHALL BE THE RESPONSIBILITY OF THE IRRIGATION CONTRACTOR. WATER METER EXISTING DOMESTIC WATER METER. CONTRACTOR TO FIELD VERIFY LOCATION AND ADEQUATE PRESSURE PRIOR TO COMMENCING IRRIGATION WORK. NO SYMBOL INSTALL WIRELESS RAIN-CLIK and CONNECT to CONTROLLER. INSTALL PER MANUFACTURER'S SPECIFICATIONS. AS APPROVEDNO SYMBOL NO SYMBOL SPEARS DBY DIRECT BURIAL WATER-PROOF WIRE CONNECTORS FOR USE ON ALL WIRE CONNECTIONS IRRIGATION CONTROL WIRE #14UF AWG DIRECT BURIAL (U.L. APPROVED) DS-400 PRE-FILLED WIRE CONNECTORS FOR USE ON ALL WIRE CONNECTIONS NO SYMBOL 3M LASCO IRRIGATION CONTROLLER HUNTER HEAVY DUTY HOSE BIB. PER CONTRACTOR. IRRIGATION CONTRACTOR TO COORDINATE FINAL LOCATIONS WITH HOMEOWNER PRIOR TO INSTALLATION.HUNTER FOR IRRIGATION DETAILS SEE SHEETS L-6 and L-7 FOR IRRIGATION SPECIFICATIONS SEE SHEET L-8 PVC PIPE SCH. 40 SLEEVING, TWICE THE DIAMETER OF PIPE OR WIRE BUNDLE CARRIED - EXTEND 12" BEYOND EDGE OF PAVING & PLACE BELOW ALL PAVING, HARDSCAPE, ETC.. 1 12" IRRIGATION PRESSURE MAINLINE SCH. 40 PVC - BURY MIN. 18" BELOW GRADE. with SCHEDULE 80 FITTINGS NON-PRESSURE LATERAL SCH 40 PVC with SCHEDULE 40 FITTINGS UP TO 1 12" - BURY MIN. 12" BELOW GRADE (SIZE AS NOTED ON PLAN). AS APPROVED AS APPROVED AS APPROVED GPMVAL.# SIZE TYPE Sq. Ft. NO SYMBOL IRRIGATION UTILITIES & VALVES IRRIGATION CONTROLLER IRRIGATION PIPING VALVE KEY REFERENCE NOTES IRRIGATION MISCELLANEOUS EQUIPMENT DRIPLINE AUTOMATIC LINE FLUSH VALVE. - PROVIDE SCH 40 SOLVENT- WELD BALL VALVE FOR FLUSH OFF OF PCV EXHAUST MANIFOLD PIPE, INSTALL FLUSH VALVE INSIDE 6" ROUND VALVE BOX, ONE AT THE END OF ANY DRIPLINE LATERAL or PVC EXHAUST HEADER. MULTIPLE FLUSH VALVES MAY BE REQUIRED WITHIN DRIPLINE LAYOUT. ALWAYS INSTALL VALVES IN OPPOSITE DIRECTIONS OF THE PVC/DRIP CONNECTION MANIFOLD. USE HUNTER FITTINGS FOR CONNECTION BETWEEN PVC LATERAL LINES AND DRIPPERLINE TUBING. NON-PRESSURE LATERAL SCH. 40 SUPPLY LATERAL. NOTE: EXHAUST LATERALS NOT SHOWN. PLD-ARV-075 AIR/VACUUM RELIEF VALVE INSTALLED with COMBINATION TEE AND A 3/4" x 1/2" REDUCER BUSHING, INSTALL AIR RELIEF ASSEMBLY INSIDE A 6" ROUND VALVE BOX AT THE HIGH POINT OF EACH PLANTER, MIN. 1 ARV PER 500' OF DISTRIBUTION TUBING. USING AIR RELIEF LATERAL, CONNECT AIR RELIEF VALVE TO ALL DRIPPERLINE LATERALS WITHIN THE ELEVATED AREA. MULTIPLE ARV'S SHALL BE REQUIRED PER RCV WITHIN UNDULATING AREAS, VERIFY QUANTITY PRIOR TO STARTING WORK, FLUSH VALVES and AIR RELIEF VALVES SHOWN DIAGRAMMATICALLY, INSTALL EMITTER BOX: 18" MIN. FROM PAVING/WALLS AND AT HIGH POINTS OF PLANTER AREA. PCZ-101 AND ACZ-075. 1" AND 3 4" ANTI-SIPHON REMOTE CONTROL VALVES FILTER SYSTEM. RAINBIRD - XFCV-06-12 SUB-SURFACE DRIPLINE TUBING WITH CHECK VALVE 0.6 GPH EMITTERS at 12" ON CENTER SPACING- ALL TUBING SHALL BE INSTALLED 4" MINIMUM BELOW FINISHED SOIL GRADE W/ 9" WIRE STAKES FIVE (4) FEET ON CENTER; VERIFY THE LAYOUT AND 12" MIN. ON CENTER SPACING IN THE FIELD PRIOR TO STARTING WORK. INSTALL SUB-SURFACE DRIP IRRIGATION SYSTEM per MANUFACTURER'S SPECIFICATIONS. A SUB-SURFACE DRIP IRRIGATION PIPE SIZE BLANK TUBING or 1/2" PVC0 - 5 GPM ZONE FLOW 8.1 - 13 GPM 1 1/2" PVC 5 - 8 GPM 3/4" PVC 1 1/4" PVC13.1 - 22 GPM 22.1 - 30 GPM 1" PVC LATERAL, MAINLINE & DRIPPERLINE SUPPLY/EXHAUST PIPE SIZING: HUNTER AS APPROVED NETAFIM HUNTER ICV-101G - REMOTE CONTROL VALVE with FLOW CONTROLHUNTER IRRIGATION LEGEND F AS APPROVED NON-PRESSURE UVR LATERAL SCH 40 PVC with SCHEDULE 40 FITTINGS UP TO 1 12" - ON GRADE, PROVIDE PIPE STABILIZERS 10' O.C. (SIZE AS NOTED ON PLAN). HC-150-FLOW SUB METER AND FLOW SENSORHUNTER IBV-101G-FS MASTER VALVEHUNTERMV SM BTT - BATTERY OPERATED REMOTE CONTROL VALVEHUNTER M A R I N E R S D R I V E 6' S I D E SE T B A C K 6' FRONT SETBACK 6' S I D E SE T B A C K 10' REAR S E T B A C K (DEVELO P M E N T A R E A ' C ' ) 25' REAR S E T B A C K F R O M T . O . B L U F F 25' REAR SETBACK FROM T.O. BLUFF 10' REAR SETBACK (DEVELOPMENT AREA 'C') 15' REAR SETBACK (DEVELOPMENT AREA 'B') 15' REAR S E T B A C K (DEVEL O P M E N T A R E A ' B ' ) FIL T E R PUMP PUMP HE A T E R 2 2 60x108 1 1 37.5" x 33.5" 37 . 5 " x 33 . 5 " W EXISTING DOMESTIC HOUSE LINE EXISTING DOMESTIC WATER METER A2 3/4" 2.2 HZ 2 226 SF A5 3/4" 6.0 HZ 2 608 SF A3 3/4" 1.4 HZ 2 142 SF A6 3/4" 3.7 HZ 2 371 SF A8 3/4" .4 HZ 2 40 SF A1 3/4" .8 HZ 1 80 SF A4 3/4" 2.0 HZ 1 200 SF A7 3/4" .4 HZ 1 40 SF SM MV A A A A A A A A A A A A F F F F F F F FF F F F F CONNECTION TEE NOTE: TEE TO BUILDING CONNECTION SHOWN HERE FOR DIAGRAMATIC PURPOSES ONLY. ACTUAL IRRIGATION TEE SHALL HAPPEN IN THE PLANTER AREA BEFORE MAINLINE LINE ENTERS THE BUILDING. P.O.C. NOTE: INSTALL NEW 1-1/4" IRRIGATION MAINLINE INSIDE PROPERTY LINE. SHOWN OUTSIDE PROPERTY FOR DIAGRAMMATIC PURPOSES ONLY. CONTRACTOR TO FIELD VERIFY WATER METER LOCATION and ADEQUATE PRESSURE AT WATER METER PRIOR TO CONSTRUCTION / TRENCHING. REMOTE CONTROL VALVES SHOWN ON MAINLINE FOR DIAGRAMMATIC PURPOSES ONLY. IRRIGATION CONTRACT`OR TO COORDINATE FINAL LOCATION OF R.C.V. MANIFOLD WITH HOMEOWNER PRIOR TO INSTALLATION/TRENCHING. IRRIGATION CONTRACTOR TO VERIFY CONTROLLER LOCATION AND STATION AVAILABILITY. NEW CONTROLLER AND/OR ADDITIONAL EXPANSION MODULES MAY BE REQUIRED. IF NEW CONTROLLER IS REQUIRED CONTRACTOR TO VERIFY FINAL LOCATION W/ HOMEOWNER. A Contractor to Field Verify All Measurements and Confirm Details to Provide Accurate Bid 2732 East Coast Highway, Suite A Corona Del Mar, CA 92625 949.673.5450 Drawn By:KM Sheet: A R D E N S T U D I O D E S I G N G HA W K E R E S I D E N C E 10 0 7 M a r i n e r s D r i v e , N e w p o r t B e a c h , C A 9 2 6 6 0 01.09.2023 11.15.2022 12.12.2022 - Initial Meeting Date: Revisions: APN: 117-663-02 PM:MP Contact Email: monica@gardenstudiodesign.com SCALE: 1/8" =1'-0" 0'2'4'8'16' L-5 Irrigation Plan General Notes: 1.Pressure regulating devices are required if water pressure is below or exceeds the recommended pressure of the specified irrigation devices. 2.Check valves or anti-drain valves are required on all sprinkler heads where low point drainage could occur. 3.I have complied with the criteria of the ordinance and applied them for the efficient use of water in the landscape design plans 4.A diagram of the irrigation plan showing hydrozones shall be kept with the irrigation controller for subsequent management purposes. 5.A Certificate of Completion shall be filled out and certified by either the designer of the landscape plans, irrigation plans, or the licensed landscape contractor for the project. 6.An irrigation audit report shall be completed at the time of final inspection. 7.All Planters to be finished with EB Stone Microbark. 8.All Planters to Have Netafim Drip Irrigation. 9.Recirculating Water Systems Shall Be Used For Water Features. 10.A Minimum of 3-inch Layer of Mulch Shall Be Applied on All Exposed Soil Surfaces of Planting Areas Except for Turf, Creeping, or Rooting Groundcovers, or Direct Seeding Applications Where Mulch is Contraindicated. 11.For Soils Less Than 6% Organic Matter in the Top 6 Inches of Soil, Compost at a Rate of Permeable Area Shall be Incorporated to a Depth of Six Inches into the Soil. ALL HEADS ARE TO BE INSTALLED WITH THE NOZZLE, SCREEN AND ARCS SHOWN ON THE PLANS. ALL HEADS ARE TO BE ADJUSTED TO PREVENT OVERSPRAY ONTO BUILDINGS, WALLS, FENCES AND HARDSCAPE. THIS INCLUDES, BUT NOT LIMITED TO, ADJUSTMENT OF DIFFUSER PIN OR ADJUSTMENT SCREW, REPLACEMENT OF PRESSURE COMPENSATING SCREENS, REPLACEMENT OF NOZZLES WITH MORE APPROPRIATE RADIUS UNITS AND THE REPLACEMENT OF NOZZLES WITH ADJUSTABLE ARC UNITS. ALL QUICK COUPLERS TO BE INSTALLED IN SHRUB OR GROUND COVER AREAS WHERE POSSIBLE. ALL QUICK COUPLERS TO BE INSTALLED AS SHOWN ON THE INSTALLATION DETAILS. INSTALL ALL QUICK COUPLERS WITHIN 18" OF HARDSCAPE. ALL PIPE UNDER PAVED AREAS TO BE INSTALLED IN SLEEVING TWICE THE DIAMETER OF THE PIPE CARRIED. SEE LEGEND FOR TYPE. ALL WIRE UNDER PAVED AREAS TO BE INSTALLED IN A SCH. 40 SLEEVE THE SIZE REQUIRED TO EASILY PULL WIRE THROUGH. ALL SLEEVES TO BE INSTALLED WITH A MINIMUM DEPTH AS SHOWN ON THE SLEEVING DETAILS. SLEEVES TO EXTEND AT LEAST 12" PAST THE EDGE OF THE PAVING. CONTRACTOR IS TO PROVIDE TWO ADDITIONAL 'CONTROL WIRES' AND ONE ADDITIONAL 'COMMON' WIRE FROM CONTROLLER ALONG ENTIRETY OF MAIN LINE TO THE LAST RCV ON EACH AND EVERY LEG OF MAIN LINE. LABEL SPARE WIRES AT BOTH ENDS. ACTUAL LOCATION FOR THE INSTALLATION OF THE BACKFLOW PREVENTION DEVICE AND THE AUTOMATIC CONTROLLER IS TO BE DETERMINED IN THE FIELD BY THE OWNER'S AUTHORIZED REPRESENTATIVE.CONTRACTOR SHALL CONTACT REPRESENTATIVE BEFORE COMMENCING WORK. INSTALL ALL EQUIPMENT AS SHOWN IN THE DETAILS AND SPECIFICATIONS. CONTRACTOR SHALL BE RESPONSIBLE TO COMPLY WITH LOCAL CITY, COUNTY AND STATE REQUIREMENTS FOR BOTH EQUIPMENT AND INSTALLATION. THE CONTRACTOR SHALL NOT WILLFULLY INSTALL ANY EQUIPMENT AS SHOWN ON THE PLANS WHEN IT IS OBVIOUS IN THE FIELD THAT UNKNOWN CONDITIONS EXIST THAT WERE NOT EVIDENT AT THE TIME THESE PLANS WERE PREPARED. ANY SUCH CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER'S REPRESENTATIVE PRIOR TO ANY WORK OR THE IRRIGATION CONTRACTOR SHALL ASSUME ALL RESPONSIBILITY FOR ANY FIELD CHANGES DEEMED NECESSARY BY THE OWNER. THIS DESIGN IS DIAGRAMMATIC. ALL EQUIPMENT SHOWN IN PAVED AREAS IS FOR DESIGN CLARITY ONLY AND IS TO BE INSTALLED WITHIN PLANTING AREAS. THE CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS REQUIRED TO PERFORM THE WORK INDICATED HEREIN BEFORE BEGINNING WORK. THE CONTRACTOR SHALL OBTAIN THE PERTINENT ENGINEERING OR ARCHITECTURAL PLANS BEFORE BEGINNING WORK. THE CONTRACTOR SHALL VERIFY SITE CONDITIONS, PROPERTY LINES, DIMENSIONS AND THE LOCATIONS OF ALL EXISTING UTILITIES, STRUCTURES AND SERVICES BEFORE COMMENCING WORK. THE LOCATIONS OF UTILITIES, STRUCTURES AND SERVICES SHOWN IN THESE PLANS ARE APPROXIMATE ONLY. ANY DISCREPANCIES BETWEEN THESE PLANS AND ACTUAL FIELD CONDITIONS SHALL BE REPORTED TO THE OWNER'S REPRESENTATIVE. CONTRACTOR SHALL THOROUGHLY FAMILIARIZE HIMSELF WITH ALL SITE CONDITIONS PRIOR TO BIDDING AND COMMENCING WORK. ALL LOCAL MUNICIPAL AND STATE LAWS, RULES AND REGULATIONS GOVERNING OR RELATING TO ANY PORTION OF THIS WORK ARE HEREBY INCORPORATED INTO AND MADE A PART OF THESE SPECIFICATIONS AND THEIR PROVISIONS SHALL BE CARRIED OUT BY THE CONTRACTOR. THE CONTRACTOR SHALL USE U.L. APPROVED GROUND ROD(S) AND/OR GROUND PLATE(S) WITH CADWELD ONE-SHOT CONNECTION PROCESS FOR CONNECTING THE CONDUCTOR WIRE TO THE ROD(S) AND/OR PLATE(S). THE NUMBER OF RODS OR PLATES SHALL DEPEND ON THE CONDUCTIVITY OF THE IMMEDIATE SOIL SURROUNDING THE ROD(S) AND/OR PLATE(S). MAXIMUM GROUND RESISTANCE SHALL BE PER CONTROLLER MANUFACTURERS SPECIFICATIONS. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROCURE AN ORIGINAL SET OF THESE PRINTED IRRIGATION PLANS FOR BIDDING AND CONSTRUCTION. COPIES OF THESE PLANS ARE NOT ALLOWED FOR BIDDING AND CONSTRUCTION AS THEY MAY NOT SHOW IRRIGATION SYMBOLS, LINE WEIGHTS, OR LINE TYPES CLEARLY. 1. CONTRACTOR SHALL REFER TO IRRIGATION LEGEND FOR CONTROLLER TYPE. FINAL LOCATION OF CONTROLLER AND ELECTRICAL POC SHALL BE CONFIRMED WITH OWNER'S AUTHORIZED REPRESENTATIVE PRIOR TO COMMENCING WORK. 15. MAINLINE SHOWN WITHIN PAVING FOR CLARITY ONLY, ACTUAL MAINLINE LOCATION TO BE WITHIN PLANTER, A MINIMUM OF 18" OFF ADJACENT HARDSCAPE AND OTHER OBSTACLES TYP. 16. CONTRACTOR SHALL PAINT ALL EXPOSED PVC PIPE WHICH IS ON-GRADE TO REDUCE VISIBILITY TO THE PUBLIC EYE AND IMPROVE THE AESTHETICS OF THE NATURAL ENVIRONMENT. PAINT SHALL BE AN OUTDOOR PAINT RESISTANT TO SUN EXPOSURE. CONTRACTOR SHALL CONFIRM PAINT COLOR AND TYPE WITH OWNER'S AUTHORIZED REPRESENTATIVE PRIOR TO COMMENCING WORK. 17. CONTRACTOR SHALL ADJUST ALL HEADS AS REQUIRED TO ACCOMMODATE ANY VERTICAL OBSTRUCTIONS THAT MAY OCCUR, INCLUDING BUT NOT LIMITED TO LIGHT POLES, FIRE HYDRANTS, ETC. CONTRACTOR SHALL ADD SPRINKLER HEADS AS REQUIRED TO ACHIEVE 100% COVERAGE IN ALL AREAS THAT REQUIRE ADJUSTING.ADTIONAL HEADS SHALL BE INSTALLED AT NO ADDITIONAL COSTS TO THE CONTRACT. VERIFY ALL HEAD LAYOUT WITH OWNER'S AUTHORIZED REPRESENTATIVE PRIOR TO COMMENCING WORK. 18. LATERAL LINES MAY BE SHOWN WITHIN PAVING FOR CLARITY ONLY, ACTUAL LOCATION TO BE WITHIN PLANTER. CONFIRM ALL LAYOUT IN FIELD WITH OWNER'S AUTHORIZED REPRESENTATIVE PRIOR TO COMMENCING WORK. 19. REMOTE CONTROL VALVES AND ISOLATION VALVE LOCATIONS ON THIS DRAWING ARE APPROXIMATE. THE LANDSCAPE CONTRACTOR SHALL STAKE OUT EACH ELECTRICAL CONTROL VALVE AND ISOLATION VALVE LOCATION FOR REVIEW AND APPROVAL BY OWNER'S AUTHORIZED REPRESENTATIVE PRIOR TO INSTALLATION OF ALL VALVES. FINAL LOCATION AND EXACT POSITIONING FOR ELECTRIC CONTROL VALVES AND ISOLATION VALVES SHALL BE DETERMINED BY THE OWNER'S AUTHORIZED REPRESENTATIVE. MINOR MODIFICATIONS OF REMOTE CONTROL VALVES AND ISOLATION VALVE LOCATIONS AS REQUESTED BY THE OWNER'S AUTHORIZED REPRESENTATIVE SHALL BE PROVIDED BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE PROJECT. FAILURE TO OBTAIN OWNER'S APPROVAL PRIOR TO THE INSTALLATION SHALL CAUSE THE CONTRACTOR TO MAKE PROJECT DIRECTED REVISIONS AT NO ADDITIONAL COST TO THE OWNER. IN GENERAL, UNLESS OTHERWISE DIRECTED BY OWNER, ALL VALVES SHALL BE INSTALLED WITHIN THREE FEET FROM EDGE OF HARDSCAPE, WALK OR CURB IN SHRUB PLANTING AREAS. 20. THE CONTRACTOR SHALL USE PROPER GROUNDING TECHNIQUES FOR GROUNDING THE CONTROLLER AND RELATED EQUIPMENT PER MANUFACTURERS SPECIFICATIONS. MEASURING FOR PROPER GROUND AT LEAST ONCE ANNUALLY, AND NECESSARY ADJUSTMENTS MADE TO COMPLY WITH MANUFACTURER SPECIFICATIONS IS RECOMMEND. 21. GENERAL IRRIGATION NOTES PRESSURE LOSS CALCULATION Hydrozones (by r.c.v. station): MAXIMUM APPLIED WATER ALLOWANCE and ESTIMATED APPLIED WATER USE CALCULATIONS: = (45.4) x (.62) [(0.55 x 1,387) + (0.45 x 0)] = M.A.W.A MAWA = (ETo) (0.62) [(0.55 x LA) + (0.45 x SLA)]EAWU = (ET ) x (.62) (Hydrozone Area) x (Plant Factor) Irrigation Efficiency (72% - 90%) E.A.W.U. - SEE TABLE BELOW o 21,472 gal./yr. · · · · · IRRIGATION CONTROLLER SCHEDULE 14,431 gal./yr. TOTAL SYSTEM LOSS: P.O.C. # FRICTION LOSS CALCULATIONS FLOW METER CONTROL VALVE MASTER VALVE METER ELEV. H.G.L. PSI PSI PSI PSI WATER METER NO. ELEVATION SIZE STATIC PRESS.HIGH LOW INFO. SOURCE: PHONE: DATE OF INFO. .433 =X REMOTE CONTROL VALVE No.SIZE MAX. DEMAND GPM ELEV. OF HIGHEST HEAD PRESS. AT RCV PSI QTY.SIZE PRESS. REGULATOR (FALL OFF)PSI WATER METER PSI BACKFLOW PREVENTER PSI GATE VALVE PSI MAINLINE PSI MAINLINE PSI MAINLINE PSI MAINLINE PSI LATERAL LINE LATERAL LINE LATERAL LINE PSI PSI PSI LATERAL LINE PSI FITTING LOSS (10%)PSI ELEVATION CHANGE (+/-)PSI PRESSURE TO OPERATE HEAD PSI TOTAL PRESSURE REQUIRED:PSI LOWEST STATIC PRESSURE AVAILABLE PSI PRE-SET REGULATED PRESSURE (IF REQ'D)PSI RESIDUAL WATER PRESSURE PSI PARCEL 2 LOT 3/4" N/A ±± - - - N/A - -- A7 1" 4.4 - - 1 3/4"0.4 --- --- --- --- 1 LINE - 323'1 1/4"0.2 --- --- --- 1 1"0.1 --- -1 1/4"- ±1"0.1 ±3/4"0.2 0.1 - 1.1 30 31.1 - - 10-15 MAXIMUM DEMAND PLANT WATER REQ. A HYDROZONE B REFERENCE PERIOD 31 DAYS C REFERENCE Eto INCHES D LANDSCAPE CO: K 1 PLANT FACTOR: K 2 VEGE. DENSITY 3 MICROCLIMATE E LANDSCAPE ET INCHES F AVERAGE DAILY ET INCHES IRRI PERFORMANCE VALUE UNITS G PRECIP RATE 0.600 IN./HR. H DISTRIB. UNIFORMITY 0.65 DECIMAL I SCHEDULE MULTIPLIER SCHEDULING PARAMETERS J IRRIGATION INTERVAL 3.5 DAYS K WATER TO APPLY INCHES L 36 MINUTES M 57 MINUTES N SELECTED RUN TIME MINUTES O CYCLE STARTS: a TIME TO RUNOFF N/A OR b SITE CONDITION 2 CYCLES 1 SOIL CATEGORY 2 - 2 SLOPE 0 - 3 COMPACTION 0 - 4 SPRINKLER TYPE 0 - SUMMARY WATER APPLIED INCHES INTERVAL DAYS CYCLES PER DAY MINUTES PER CYCLE 29 MINUTES THESE IRRIGATION SCHEDULES ARE FOR TWICE WEEKLY IRRIGATION PER CITY OF LAGUNA BEACH REQUIREMENTS. THE UPPER BOUNDARY IRRIGATION RUN TIME HAS BEEN SELECTED FOR THE INITIAL PLANT ESTABLISHMENT PERIOD (MINIMUM ONE YEAR). ONCE PLANTS ARE ESTABLISHED THE RUN TIMES MAY BE SHORTENED TO THE LOWER BOUNDARY. ROUTINE PLANT OBSERVATION AND MAINTENANCE ARE REQUIRED FOR OPTIMAL PLANT HEALTH. VALUE UNITS IRRIGATION SCHEDULE SAMPLE: JULY 5.3 ETo for DRIP VALUE UNITS VALUE UNITS THIS IRRIGATION SYSTEM HAS BEEN DESIGN FOR A PRESSURE OF 55 PSI. IF THE WATER PRESSURE VARIES BY MORE THAN 20% THE CONTRACTOR SHALL CONTACT THE LANDSCAPE ARCHITECT ON HOW TO PROCEED. FAILURE TO DO SO WILL ALL REPAIRS/REPLACEMENTS ON THE RESPONSIBILITY OF THE CONTRACTOR. RCV STATION ETo PLANT FACTOR HYDROZONE AREA (SQ. FT.)CONV. FACTOR IRRIGATION EFFICIENCY AREA = (H.A. x P.F) HZ1 0.62 HZ2 0.62 TREE BUBBLER 0.3 81% 81% 96 SHRUB DRIP = 0.3 320 WATER USE + SLA( ) = (ET ) x (.62) .81 o + 0( )416 416 L-6 Contractor to Field Verify All Measurements and Confirm Details to Provide Accurate Bid 2732 East Coast Highway, Suite A Corona Del Mar, CA 92625 949.673.5450 Drawn By:KM Sheet: A R D E N S T U D I O D E S I G N G HA W K E R E S I D E N C E 10 0 7 M a r i n e r s D r i v e , N e w p o r t B e a c h , C A 9 2 6 6 0 01.09.2023 11.15.2022 12.12.2022 - Initial Meeting Date: Revisions: APN: 117-663-02 PM:MP Contact Email: monica@gardenstudiodesign.com SCALE: 1/8" =1'-0" 0'2'4'8'16' MAR.JAN FEB.APR.MAY JUN.JUL.DEC.AUG.SEP.NOV.OCT. = 45.4 C.I.M.I.S. STATION: NEWPORT BEACH ET DATA MONTHLY 2.6 2.5 3.5 4.2 5.0 4.7 5.3 5.3 4.5 3.3 2.5 2.0 Irrigation Calculations Contractor to Field Verify All Measurements and Confirm Details to Provide Accurate Bid 2732 East Coast Highway, Suite A Corona Del Mar, CA 92625 949.673.5450 Drawn By:KM Sheet: A R D E N S T U D I O D E S I G N G HA W K E R E S I D E N C E 10 0 7 M a r i n e r s D r i v e , N e w p o r t B e a c h , C A 9 2 6 6 0 01.09.2023 11.15.2022 12.12.2022 - Initial Meeting Date: Revisions: APN: 117-663-02 PM:MP Contact Email: monica@gardenstudiodesign.com SCALE: 1/8" =1'-0" 0'2'4'8'16' SURFACE MOUNTING BRACKET WIRELESS RAIN SENSOR WIRED NORMALLY CLOSED MOUNTING SCREW (1 OF 2) WIRE TO IRRIGATION CONTROLLER - UNLESS WIRELESS SPECIFIED. MOUNT IN AN AREA THAT WILL BE EXPOSED TO UNOBSTRUCTED RAINFALL, BUT NOT IN THE PATH OF SPRINKLER SPRAY. 1 3 1 4 2 3 4 5 SECTION/ELEVATION LEGEND: NOTE: D RAIN SENSOR Scale: N.T.S. RIN-SNR WITH RECOMMENDED TOOL CONNECTOR INSERT CRIMP COPPER SLEEVE INSTALLED STRIP AND TWIST WIRES FOR PROPER CONNECTION NOTE: FILL OUTER CASE WITH SEALER PRIOR TO FINAL ASSEMBLY. OUTER CASE OF CONNECTOR LOW VOLTAGE WIRES, 3 MAXIMUM SECTION E BALL VALVE Scale: N.T.S. VAL-BAL CL 6" 3" LEGEND: VALVE BOX INDENTIFICATION (SEE DETAIL THIS SHEET) FINISHED GRADE DO NOT INSTALL IN TURF AREA. PLASTIC ROUND VALVE BOX WITH BOLT DOWN COVER, USE STAINLESS BOLT NUT AND WASHER. HEAT BRAND "GV" ONTO LID. FINISHED GRADE IN TURF AREA GATE VALVE BRICK SUPPORTS 6" PVC CL. 160 PIPE ONE CUBIC FOOT 3/4" CRUSHED GRAVEL SCH 40 PVC COUPLING SCH 40 COUPLING IRRIGATION MAINLINE SCH 80 PVC T.O.E. NIPPLE, 6" LONG 1 1 2 3 4 9 10 8 7 6 5 2 3 4 5 6 7 8 9 10 11 C 4" 4" BA 24" 12"18" 4" TO 6" IN SIZE 1/2" TO 3" IN SIZE DIMENSION C B C C A CC H PIPE INSTALLATION Scale: N.T.S. PIP-INS 1 LEGEND: 1 FINISH GRADE CLEAN COMPACTED BACKFILL NON-PRESSURE LATERAL LINES, SEE SPECIFICATIONS CONTROL WIRES, SEE SPECIFICATIONS UNDISTURBED SOIL PRESSURE MAINLINE, SEE SPECIFICATIONS NOTE: LATERAL LINES SHALL BE INSTALLED PITCHED AT 1% SLOPE TO DRAIN TO LOW POINT FOR WINTERIZATION 2 3 4 5 6 1. F WIRE CONNECTION Scale: N.T.S. PAVING LATERAL LINES DENSITY OF EXISTING SAND BACKFILl COMPACTED TO THE UNDISTURBED SOIL CONTROL WIRES IN SCH 40 SLEEVE IN SCH 40 SLEEVE C 24" D 4" IN SCH 40 SLEEVE OF THE PIPE OR WIRE DETAIL ALSO FOR PIPE PVC SLEEVES TO BE TWICE THE DIAMETER BUNDLE CARRIED. INSTALLED IN ROCK SOIL. B 24" A 36"1/2" TO 4" IN SIZE DIMENSION PRESSURE MAINLINE C B A DDDD I SLEEVE INSTALLATION Scale: N.T.S. PIP-SLE 10 46325 SOIL 2 PROVIDE TWO LAYERS of WARNING TAPE RUNNING CONTINUOUS ALONG ROUTE OF THE MAINLINE. ONE SHALL BE LOCATED IMMEDIATELY ON TOP OF THE MAINLINE PIPE AND ONE 12" ABOVE THE TOP OF MAINLINE. FINISH GRADE RECTANGULAR VALVE BOX REFER TO SPECIFICATIONS SPARE WIRE LABEL CONTROL AND/OR COMMON WIRE, REFER TO SPECIFICATIONS 1 2 3 4 5 2 3 4 5 PEA GRAVEL BACKFILL (ONE CUBIC FOOT MINIMUM) C SPARE WIRE BOX Scale: N.T.S. FOR IRRIG. CONTROL & COMMON WIRE (ONE SHOWN) INSTALL MIN. 6"-12" ABOVE HIGHEST POINT OF DISCHARGE 30-INCH LINEAR LENGTH OF WIRE, COILED WATERPROOF CONNECTION ID TAG ANTI-SIPHON VALVE: SEE IRRIGATION LEGEND PRESSURE REGULATING FILTER per LEGEND. -OPTIONAL DEPENDING ON AVAILABLE STATIC PRESSURE PVC SCH 80 UNION PVC SCH 40 MALE ADAPTER UV RADIATION RESISTANT OR PAINTED PVC SCH 40 PIPE (1 OF 2) FINISH GRADE/TOP OF MULCH PVC SCH 40 ELL (1 OF 2) PVC MAINLINE PIPE PVC LATERAL LINE A DRIP ANTI-SIPHON VALVE Scale: N.T.S. 2 3 4 5 6 7 8 9 10 11 12 2 3 4 5 6 7 8 9 12 1110 3" 2" MIN. FINISHED GRADE IN SHRUB AREAS PVC LATERAL (OR EXHAUST HEADER) 3/4" GRAVEL SUMP (1 CUBIC FOOT) BRICK SUPPORTS - THREE S x 1/2" PVC 90 ELL (SIZE AS REQ'D) LINE FLUSHING VALVE per IRRIGATION LEGEND VALVE BOX SEE SPECS. B FLUSH VALVE Scale: N.T.S. 2 3 4 5 6 7 2 4 3 5 6 7 J ANTI-SIPHON VALVE Scale: N.T.S. *NOTE* ANTI-SIPHON VALVES SHOULD BE INSTALLED 6-12" ABOVE THE HIGHEST SPRINKLER HEAD WITHIN THE ZONE, OR, ACCORDING TO LOCAL CODE. 6" M I N ANTI-SIPHON VALVE - SEE IRRIGATION LEGEND for TYPE. INSTALL per MANUFACTUER'S RECOMMENDATIONS. 18 - 24" COILED WIRE. WATERPROOF CONNECTORS (2) UVR PVC PIPE AND FITTINGS FINISH GRADE MAINLINE PIPE AND FITTINGS LATERAL PIPE AND FITTINGS 1 2 3 4 5 6 7 1 2 3 4 6 7 5 L-7 Contractor to Field Verify All Measurements and Confirm Details to Provide Accurate Bid 2732 East Coast Highway, Suite A Corona Del Mar, CA 92625 949.673.5450 Drawn By:KM Sheet: A R D E N S T U D I O D E S I G N G HA W K E R E S I D E N C E 10 0 7 M a r i n e r s D r i v e , N e w p o r t B e a c h , C A 9 2 6 6 0 01.09.2023 11.15.2022 12.12.2022 - Initial Meeting Date: Revisions: APN: 117-663-02 PM:MP Contact Email: monica@gardenstudiodesign.com SCALE: 1/8" =1'-0" 0'2'4'8'16' SYMBOL ON PLANS REPRESENTS THE INSTALLATION OF ALL OF THE EQUIPMENT SHOWN ON THE DETAIL ABOVE WATER METER IS THE EXISTING UNIT. IRRIGATION POINT OF CONNECTION SHALL BE MADE FROM THE SERVICE LINE TO THE HOUSE ISOLATION VALVE SHALL BE INSTALLED ON THE IRRIGATION P.O.C.. IF REQUIRED PRESSURE REGULATOR SHALL BE INSTALLED DOWNSTREAM OF BALL VALVE, IF REQUIRED IRRIGATION MAINLINE SHALL BE ROUTED TO REMOTE CONTROL VALVES. MAINLINE TO REMOTE CONTROL VALVES PRESSURE REGULATOR, REQUIRED FOR STATIC WATER PRESSURE OVER 80 PSI. CONTRACTOR TO VERIFY WATER PRESSURE PRIOR TO STARTING WORK. BALL VALVE WATER METER SERVICE LINE TO HOUSE M A RESIDENTIAL CONNECTION Scale: N.T.S. 1 2 3 4 5 1 2 3 5 4 AR LF ALIGN DRIP TUBING LATERALS PARRALLEL TO THE CONTOURS OF THE SLOPE LINE FLUSHING VALVE PLUMBED TO PVC AREA PERIMETER START CONNECTION EXHAUST HEADER COMPRESSION TEE SUBSURFACE DRIP TUBING per IRRIGATION LEGEND AIR/VACUUM RELIEF VALVE (PLUMBED to DRIP LINE ONE AT EACH HIGH POINT) BLANK TUBING CENTERED ON MOUND OR BERM SUPPLY HEADER REMOTE CONTROL VALVE AR LF PVC SUPPLY HEADER TOP OF SLOPE AIR/VACUUM RELIEF ASSEMBLY LINE FLUSHING VALVE ASSEMBLY PVC EXHAUST HEADER TOE OF SLOPE REMOTE CONTROL VALVE CONVENTIONAL SPACING ON TOP 2/3 OF SLOPE CONVENTIONAL SPACING PLUS 25% ON BOTTOM 1/3 OF SLOPE ALIGN DRIP TUBING LATERALS PARRALLEL TO THE CONTOURS OF THE SLOPE 3" 2" MIN. FINISHED GRADE IN TURF AREAS FINISHED GRADE IN SHRUB AREAS RAINBIRD ARV-100 VALVE KIT, AIR / VACUUM RELIEF VALVE PLASTIC ROUND VALVE BOX PER IRRIGATION LEGEND, SUBSURFACE DRIP TUBING BRICK SUPPORTS LANDSCAPE FABRIC 3/4" ROCK, 1 CUBIC FT. RAINBIRD EASY FIT TEE, MDCFTEE AND FPT ADAPTER-MDCF75FPT E DRIPPERLINE: IRREGULAR AREAS Scale: N.T.S. C DRIPPERLINE LAYOUT Scale: N.T.S. B DRIP AIR RELIEF VALVE Scale: N.T.S. 2 3 4 5 6 7 8 9 10 2 3 4 5 6 7 8 910 2 3 4 5 6 7 8 9 2 3 4 5 6 798 2 3 4 5 6 7 8 9 6 5432 7 8 9 AV ZONE FLUSH VALVE PLUMBED TO PVC AREA PERIMETER SUBSURFACE IRRIGATION TUBING PER IRRIGATION LEGEND MANIFOLD CONNECTION (PVC TO ELBOW) SCH. 40 PVC FLUSH MANIFOLD AIR/VACUUM RELIEF VALVE (PLUMED TO GEOFLOW TUBING AT EACH HIGH POINT) COMPRESSION TEE PVC SUPPLY MANIFOLD REMOTE CONTROL VALVE PER IRRIGATION LEGEND FV 2 3 4 5 6 7 8 9 9 8 2 3 4 5 6 7 D DRIPPERLINE LAYOUT Scale: N.T.S. HOSE BIB PER IRRIGATION LEGEND THREADED COUPLER SCH 80 NIPPLE STAINLESS STEEL CLAMP DURA PRE-ASSEMBLED SWING JOINT WITH ONE PIECE BRASS MIPT NIPPLE #4 x 36" REBAR STAKES, 2 REQUIRED LANDSCAPE FABRIC 3/4" DRAIN ROCK. FILL VALVE BOX TO JUST BELOW LID PLASTIC ROUND VALVE BOX WITH COVER REMOVED. FINISHED GRADE IN TURF AREAS IRRIGATION MAINLINE 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1111 L HOSE BIB Scale: N.T.S. L-8 A. GENERAL NOTES B. FIELD OBSERVATIONS C. MATERIALS NOTES (CONTINUED)D. PLASTIC PIPE NOTES (CONTINUED)F. RECORD AND AS-BUILT DRAWINGS (CONT'D) C. MATERIALS NOTES D. PLASTIC PIPE NOTES E. IRRIGATION EQUIPMENT NOTES F. RECORD AND AS-BUILT DRAWINGS G. EQUIPMENT TO BE FURNISHED L-9 Contractor to Field Verify All Measurements and Confirm Details to Provide Accurate Bid 2732 East Coast Highway, Suite A Corona Del Mar, CA 92625 949.673.5450 Drawn By:KM Sheet: AR D E N S T U D I O D E S I G N G HA W K E R E S I D E N C E 10 0 7 M a r i n e r s D r i v e , N e w p o r t B e a c h , C A 9 2 6 6 0 01.09.2023 11.15.2022 12.12.2022 - Initial Meeting Date: Revisions: APN: 117-663-02 PM:MP Contact Email: monica@gardenstudiodesign.com SCALE: 1/8" =1'-0" 0'2'4'8'16'