Loading...
HomeMy WebLinkAboutPA2023-0035_20230316_PRR_BLDGTmplt: 06/07/19 P ROJECT R EVIEW R EQUES T C O M M U N I T Y D E V E L O P M E N T D E P AR T M E N T Planning Division Please Distribute to: Building – Tonee Thai Public Works – David Keely Fire – James Gillespie Date: March 6, 2023 Please return PRR and Plans to Staff Planner Oscar Orozco, Assistant Planner (x3219) Applicant: Mathew Gummow Contact: 949-529-9070 agencyreviews@alderjames.com Project Name Gelato Takeout Establishment Address: 3500 E. Coast Highway (PA2023-0035) Minor Use Permit Project Description: Minor Use Permit for a Gelato Takeout establishment within an existing 610 square foot tenant suite at 3500 E Coast Hwy. REPORT REQUESTED BY: March 17, 2022 ZONING ADMINISTRATOR HEARING DATE: TBD Check all that apply: ❑ No comments on the project as presented. Notes: 1. Where two doors swing into the space between the restaurant and the corridor, compliance with CBC 1010.1.7 and 11B-404.2.6 will be required. 2. Where the turns in the circulation path occur around the walls and equipment between Gelato Sales and Work/Storage, and between Work/Storage and Storage, compliance with CBC 11B-403.5.2 will be required. 3. According to CBC 11B-202.4(8), 20% of the construction valuation will be required to be invested in upgrading existing non-compliant disabled access features. The public restrooms, the width of the corridor between the restaurant and the public restrooms, and main entrance door will need to be field verified for compliance with requirements in CBC 11B-603, 11B-604 and 11B-606; CBC 11B-404.2.4 and CBC 11B-404 respectively. Any non-compliant features will need to be identified, and plans and details provided for the upgrading of those features to comply with the current code (CBC 2022). X Application of Standard Code requirements are not expected to alter the project design. ❑ Recommended conditions of approval are attached. ❑ Application of Standard Code requirements or the attached conditions of approval will substantially impact or alter the design of the project. ❑ I contacted the applicant on ❑ To schedule an appt. for Code review ❑ To discuss the following (see notes) Tmplt: 06/07/19 4. The service counter will need to comply with CBC 11B- 904.4 (CBC 11B-227.3). 5. Provide calculations of the occupant load according to CBC 1004. If the occupant load for a B occupancy is 49 or less, a single exit will be required (CBC Table 1006.2.1). Eric Skarin 3270 03/16/23 Signature Ext. Date