HomeMy WebLinkAboutPA2023-0043_230411_306 Via Lido Nord_CDP Submittal Set_Revision ALICENCE STAMP:
THESE DRAWINGS ARE THE PROPERTY OF OATMAN
ARCHITECTS AND SHALL NOT BE MODIFIED OR USED ON ANY
OTHER PROJECT OR SITE WITHOUT WRITTEN PERMISSION.
IT IS THE OWNER'S AND IT'S GENERAL CONTRACTOR'S
RESPONSIBILITY, PRIOR TO OR DURING CONSTRUCTION, TO
NOTIFY THE ARCHITECT IN WRITING OF ANY PERCEIVED
ERRORS OR OMISSIONS IN THE PLANS AND/ OR GENERAL
NOTES OF WHICH A CONTRACTOR THOROUGHLY
KNOWLEDGEABLE WITH THE BUILDING CODES AND MEANS &
METHODS OF CONSTRUCTION SHOULD REASONABLY BE
AWARE. WRITTEN INSTRUCTIONS ADDRESSING SUCH
PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED
FROM THE ARCHITECT PRIOR TO THE OWNER OR OWNER'S
CONTRACTOR PROCEEDING WITH THE WORK. THE OWNER
WILL BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION
IF THESE PROCEDURES ARE NOT FOLLOWED.
NOTE: THE ORIGINAL SIZE OF THIS DRAWING SHEET IS: 36"X48"
PROJECT NUMBER:
SUBMITTAL:
REVISION:
DATE DESCRIPTION
PERMIT NUMBER:
CLIENT:
4/11/2023 1:55:41 PM
T1.0
COVER SHEET
2022001
RI
Z
K
O
R
E
S
I
D
E
N
C
E
30
6
V
I
A
L
I
D
O
N
O
R
D
NE
W
P
O
R
T
B
E
A
C
H
,
C
A
9
2
6
6
3
DE
S
I
G
N
D
E
V
E
L
O
P
M
E
N
T
CAMILLE AND JOUMANA RIZKO
PRINCIPAL: HOMER OATMAN
DRAWN BY: ALLIE SCHIEBLE
NO. DATE DESCRIPTION
PROJECT TEAM
COUNTY ASSESSOR'S MAP
1. SEPARATE DRAWING SUBMITTAL(S) AND PERMIT(S) IS/ARE REQUIRED FOR THE GRADING PLAN, LANDSCAPE PLANS,
SWIMMING POOL AND SPA, POOL AND SPA MECHANICAL EQUIPMENT, ANY SITE RETAINING WALLS OVER 4 FEET HIGH
FROM THE BOTTOM OF THE FOUNDATION TO TOP OF WALL, ANY BLOCK WALLS OVER 3.5 FEET, MASONRY OR
CONCRETE FENCES OVER 3.5 FEET HIGH, DETACHED PATIO COVERS, TRELLISES, ACCESSORY BUILDING(S) . . .ETC.
2. SEPARATE DRAWING SUBMITTAL(S) AND PERMIT(S) IS/ARE REQUIRED FOR THE N.F.P.A. 13-D AUTOMATIC FIRE
SPRINKLER SYSTEM. THE SYSTEM SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH THE 2013 N.F.P.A. 13-D
AND AMENDMENTS AS ADOPTED BY THE LOCAL JURISDICTION. SPRINKLER IS REQUIRED AT PLANS SHALL BE SUBMITTED
AND APPROVED BY PRIOR TO ISSUING A BUILDING PERMIT OR SHALL BE OBTAINED PRIOR TO CALLING FOR ROOF
SHEATHING INSPECTION. THE SYSTEM SHALL BE OPERATIONAL PRIOR TO THE ISSUANCE OF A CERTIFICATE OF USE AND
OCCUPANCY FOR ALL ONSITE STRUCTURES.
DEFERRED SUBMITTALS
ABBREVIATIONS
CLIENT:
CAMILLE AND JOUMANA RIZKO
306 VIA LIDO NORD
NEWPORT BEACH, CA 92663
ARCHITECT:
OATMAN ARCHITECTS, INC.
412 31ST STREET
NEWPORT BEACH, CA 92663
949.675.1755 OFFICE
949.657.1758 FAX
CONTACT: ALLIE SCHIEBLE
INTERIOR DESIGNER:
INSERT DESIGN STUDIO
245 FISCHER AVENUE, SUITE A-8-A
COSTA MESA, CA 92626
714.714.0060 (OFFICE)
CONTACT: JENNA SCHUMACHER
STRUCTURAL ENGINEER:
BORM INTERNATIONAL
2211 MICHELSON DRIVE, SUITE 450
IRVINE, CA 92612
949.752.0601
CONTACT: MASOUD BOKAIE
MECHANICAL/PLUMBING ENGINEER/ELECTRICAL ENGINEER:
CIVIL/SURVEYOR:
TOAL ENGINEERING, INC.
139 AVENIDA NAVARRO
SAN CLEMENTE, CA
949.492.8586 OFFICE
CONTACT: VIKTOR MEUM
CITY OF NEWPORT BEACH
SQUARE FOOTAGE CALCS
W. WEST
W/ WITH
W.C. WATER CLOSET
WD. WOOD
W.H. WATER HEATER
W/O WITHOUT
WP. WATERPROOF
WSCT. WAINSCOT
WT. WEIGHT
WDW. WINDOW
SUSP. SUSPENDED
SUB-F
L.
SUB-FLOOR
SW SOLID WOOD
SYM. SYMMETRICAL
S4S SURFACED 4
SIDES
T.B. TOWEL BAR
T.B.D TO BE
DETERMINED
T.C. TOP OF CURB
TEL. TELEPHONE
TER. TERRAZZO
TEMP. TEMPERED
T&G TONGUE AND
GROOVE
THK. THICK
T.O.C. TOP OF CURB
T.O.D. TOP OF DECKING
T.O.P. TOP OF PLATE
T.O.PA
R.
TOP OF PARAPET
T.O.S. TOP OF SLAB
T.O.PA
V.
TOP OF
PAVEMENT
T.P. TOILET PAPER
DISPENSER
TRANS
.
TRANSOM
TRD. TREAD
T.V. TELEVISION
T.W. TOP OF WALL
TYP. TYPICAL
UNF. UNFINISHED
U.O.N. UNLESS
OTHERWISE
NOTED
UR. URINAL
VAN. VANITY
VLT. VAULT
VERT VERTICAL
VEST. VESTIBULE
V.S. VEGI SINK
REQ. REQUIRED.
REQUIREMENTS
RESIL. RESILIENT
RM. ROOM
R.O. ROUGH OPENING
R.OS. REVERSE
OSMOSIS
RWD. REDWOOD
R.W.L. RAIN WATER
LEADER
S. SOUTH
S.C. SOLID CORE
S.C.D. SEAT COVER
DISPENSER
SCHED
.
SCHEDULE
S.D. SOAP DISPENSER
SECT. SECTION
S.F. SQUARE FEET
S.H. SINGLE HUNG
SHR. SHOWER
SHT. SHEET
SHTG. SHEATHING
SIM. SIMILAR
SKYLT. SKYLIGHT
SLPG. SLOPING
SLDR. SLIDER/ SLIDING
S.N.D. SANITARY NAPKIN
DISPENSER
S.N.R. SANITARY NAPKIN
RECEPTACLE
SP. SPACE
SPEC. SPECIFICATIONS
SQ. SQUARE
S.ST. STAINLESS STEEL
STA. STATION
STD. STANDARD
STL. STEEL
STOR. STORAGE
STRL. STRUCTURAL
STRUC
T'L
STRUCTURAL
STRUC
T
STRUCTURE
S.S. SERVICE SINK
PRCST
.
PRECAST
PL. PLATE
P.LAM. PLASTIC
LAMINATE
PLAS. PLASTER
PNL. PANEL
PTD. PAINTED
PLUMB
.
PLUMBING
PLYW
D.
PLYWOOD
PL PROPERTY LINE
PR. PAIR
P.T. PRESSURE
TREATED
PREFA
B
PREFABRICATED
P.T.D. PAPER TOWEL
DISPENSER
P.T.D/
R
COMBINATRION
PAPER TOWEL
DISPENSER &
RECEPTACLE
PTN. PARTITION
P.T.R. PAPER TOWEL
RECEPTACLE
Q.T. QUARRY TILE
R. RISER
RAD. RADIUS
R.A.G. RETURN AIR
GRILLE
R RADIUS
R.C.W. RECESSED COLD
WATER
R.D. ROOF DRAIN
REF. REFERENCE
REFR. REFRIGERATOR
REV REVERSE
REINF REINFORCE,
REINFORCED
RGTR. REGISTER
R.H.B. RECESSED HOSE
BIBB
LT. LIGHT
LVD. LOUVERED
MAINT. MAINTENANCE
MAX. MAXIMUM
M.B. MACHINE BOLT
M.C. MEDICINE CABINET
MDF MEDIUM DENSITY
FIBER BD.
MECH. MECHANICAL
MEMB. MEMBRANE
MET. METAL
MFGR. MANUFACTURER
MH. MANHOLE
MIN. MINIMUM
MIR. MIRROR
MISC. MISCELLANEOUS
M.O. MASONRY
OPENING
MTD. MOUNTED
MTL METAL
MUL. MULLION
N. NORTH
N.I.C. NOT IN CONTRACT
NO.
OR #
NUMBER
NOM. NOMINAL
N.T.S. NOT TO SCALE
O/ OVER
O.A. OVERALL
OBS. OBSCURE
O.C. ON CENTER
O.D. OUTSIDE
DIAMETER (DIM.)
OFF. OFFICE
O.H.C. OVERHEAD
CABINET
OPNG. OPENING
OPP. OPPOSITE
PAN. PANTRY
P.D. POCKET DOOR
FURR. FURRING
FUT. FUTURE
GA. GAUGE
GALV. GALVANIZED
G.B. GRAB BAR
GL. GLASS
GND. GROUND
G.P.F. GALLONS PER
FLUSH
G.P.M. GALLONS PER
MINUTES
GR. GRADE
GYP. GYPSUM
GYP.
BD.
GYPSUM BOARD
G.B. GYPSUM BOARD
H.B. HOSE BIBB
H.C. HOLLOW CORE
HDWD. HARDWOOD
HDWE. HARDWARE
HDR. HEADER
H.M. HOLLOW METAL
HORIZ. HORIZONTAL
HR. HOUR
HT. HEIGHT
H.V.A.
C
HEATING
VENTILATING AIR
CONDITIONING
HORZ HORIZONTAL
I.D. INTERIOR
DESIGNER
I.DIA. INSIDE DIAMETER
INSUL. INSULATION
INT. INTERIOR
JAL. JALOUSIE
JAN. JANITOR
JT. JOINT
LAM. LAMINATE
LAV. LAVATORY
LIN. LINEN
LKR. LOCKER
ENCL. ENCLOSED
E.P. ELECTRICAL
PANELBOARD
EQ. EQUAL
EQPT. EQUIPMENT
E.W.C. ELECTRIC WATER
COOLER
EXST. EXISTING
EXP. EXPANSION
EXPO. EXPOSED
EXT. EXTERIOR
F.A. FIRE ALARM
F.A.U FORCED AIR UNIT
F.B. FLAT BAR
F.D. FLOOR DRAIN
FDN. FOUNDATION
F.E. FIRE
EXTINGUISHER
F.E.C. FIRE
EXTINGUISHER
CABINET
F.F. FINISH FLOOR
F.G. FINISH GRADE OR
FIXED GLASS
F.GAS FUEL GAS
F.H.C. FIRE HOSE
CABINET
FIN. FINISH
FIX. FIXED
FL. FLOOR
FLASH. FLASHING
FLUOR
.
FLUORESCENT
F.O.C. FACE OF
CONCRETE
F.O.F. FACE OF FINISH
F.O.M. FACE OF MULLION
F.O.S. FACE OF STUDS
F.P. FIREPLACE
FPRF. FIREPROOF
FR. FRENCH
FRAM'
G
FRAMING
F.S. FULL SIZE
FT. FOOT OR FEET
FTG. FOOTING
C.B. CATCH BASIN
CEM. CEMENT
CER. CERAMIC
C.I. CAST IRON
C.G. CORNER GUARD
CLG. CEILING
CLKG. CAULKING
COL. COLUMN
CONC. CONCRETE
CONN. CONNECTION
CONST
R.
CONSTRUCTION
CONT. CONTINUOUS
C.O.F. CORNER OF
FINISH
CORR. CORRIDOR
CSMT. CASEMENT
CNTR. CENTER
CTSK. COUNTERSUNK
DBL. DOUBLE
DEPT. DEPARTMENT
D.F. DRINKING
FOUNTAIN
DET. DETAIL.
DIA. DIAMETER
DIM. DIMENSION
DN. DOWN
D.O. DOOR OPENING
DR. DOOR
DS. DOWNSPOUT
D.S.P. DRY STANDPIPE
D.V. DRYER VENT
DW DISHWASHER
DWG'S DRAWINGS
DWR. DRAWER
E. EAST
EA. EACH
E.D.F DRINK FOUNTAIN
E.J. EXPANSION JOINT
EL. ELEVATION
ELEC. ELECTRICAL
ELEV. ELEVATOR
EMER. EMERGENCY
& AND
< ANGLE
@ AT
₵ CENTERLINE
Ø DIAMETER OR
ROUND
# POUND OR
NUMBER
(E) EXISTING
A.B. ANCHOR BOLT
ABV. ABOVE
A.C. AIR CONDITIONER
ACOUS
.
ACOUSTICAL
A.D. AREA DRAIN
ADJ. ADJUSTABLE
A.F.F. ABOVE FINISH
FLOOR
AGGR. AGGREGATE
AL. ALUMINUM
ALUM. ALUMINUM
APPR
OX.
APPROXIMATE
ARCH. ARCHITECT
ARCH'
L.
ARCHITECTURAL
ASPH. ASPHALT
A.V. AUDIO/ VIDEO
AWNG. AWNING
BD. BOARD
BDRM. BEDROOM
B.I. BUILT-IN
BITUM. BITUMINOUS
BLDG. BUILDING
BLK. BLOCK
BLKG. BLOCKING
BLT. BOLT
BM. BEAM
B.O.B. BOTTOM OF
BEAM
BOT. BOTTOM
B.S. BAR SINK
CAB. CABINET
2019 CALIFORNIA RESIDENTIAL CODE - ALONG WITH
SECTION R327
2019 CALIFORNIA BUILDING CODE - ALONG WITH CHAPTER
7A
2019 CALIFORNIA MECHANICAL CODE
2019 CALIFORNIA PLUMBING CODE
2019 CALIFORNIA ELECTRICAL CODE
2019 CALIFORNIA ENERGY CODE
2019 CALIFORNIA GREEN BUILDING STANDARDS CODE
(CALGREEN)
CHAPTER 15 NEWPORT BEACH MUNICIPAL CODE (NMBC)
USE: SINGLE FAMILY DETACHED
RESIDENCE
OCCUPANCY TYPE: R-3 / U (LIGHT STORAGE &
PRIVATE GARAGE)
TYPE OF CONSTRUCTION: V-B
SPRINKLERS: YES, DEFERRED SUBMITTAL
SETBACKS (MAP S-3A):
FRONT (VIA LIDO NORD): 4FT
FRONT (NEWPORT BAY): 0 FT
SIDE: 4 FT
HEIGHT LIMIT:
CITY: 28 FT FLAT ROOF/33 FT
SLOPED ROOF W/ 3:12 MIN.
PITCH
LICA (HOA): 24 FT FROM AVG. TOC
FLOOD ZONE: 'X'
VICINITY MAP CODES AND REQUIREMENTS
ARCHITECTURAL
A1.0 ARCHITECTURAL SITE PLAN
A2.0 SLAB PLAN
A3.0 DEMOLITION PLAN
A4.0 FLOOR PLANS
A4.1 FLOOR AREA EXHIBIT
A5.0 ROOF PLAN
A6.0 EXTERIOR ELEVATIONS
A6.1 EXTERIOR ELEVATIONS
A7.0 BUILDING SECTIONS
A7.1 BUILDING SECTIONS
A9.0 SCHEDULES
GENERAL
T1.0 COVER SHEET
E1 CONSTRUCTION POLLUTION PREVENTION
PLAN
LIDO ISLE COMMUNITY ASSOC.
SQUARE FOOTAGE CALCS
NEW TOTAL SQUARE FOOTAGE:
FIRST FLOOR (INCLUDING GARAGE): 2,679 SF
SECOND FLOOR:2,381 SF
TOTAL:5,060 SF
COVERED TERRACE: 369 SF
FRONT 2ND FL. BALCONY: 124 SF
REAR 2ND FL. BALCONY: 221 SF
LOT SIZE:4,050 SF
LOT DIMENSIONS: 90' X 45'
BUILABLE AREA:
LOT SIZE (4,050 SF) MINUS
SETBACKS (868 SF): 3,182 SF
ALLOWABLE FLOOR AREA:
1.75 X BUILDABLE AREA: 5,568 SF
OPEN VOLUME:
15% OF BUILDABLE AREA REQUIRED: 477 SF
PROVIDED:689 SF
NEW 2-STORY SINGLE FAMILY DWELLING WITH 5
BEDROOMS, 5.5 BATHROOMS AND ATTACHED 3-CAR
GARAGE. NEW SUBTERRANEAN STORAGE BELOW TERRACE
AT BAY SIDE.
CITY: NEWPORT BEACH
COUNTY: ORANGE
COMMUNITY: LIDO ISLE COMMUNITY ASSOC.
GENERAL PLAN LAND USE: RM MULTIPLE RESIDENTIAL
ZONING: RM MULTIPLE RESIDENTIAL
PARCEL (APN): 423-144-14
TRACT: 907
LOT: 846 AND WESTERLY 1/2 OF
845
LEGAL DESCRIPTION
PROJECT SCOPE
SHEET INDEX
RIZKO RESIDENCE
CIVIL
TP-01 TOPOGRAPHIC SURVEY
C1 PRELIMINARY GRADING PLAN
NEW TOTAL SQUARE FOOTAGE:
FIRST FLOOR (INCLUDING GARAGE): 2,679 SF
SECOND FLOOR:2,619 SF
TOTAL:5,298 SF
LOT SIZE:4,050 SF
LOT DIMENSIONS: 90' X 45'
BUILABLE AREA:
LOT SIZE (4,050 SF) MINUS
SETBACKS (868 SF): 3,182 SF
ALLOWABLE FLOOR AREA:
1.70 X BUILDABLE AREA: 5,409.4 SF
CITY OF NEWPORT BEACH
GRADE ESTABLISHMENT CALCS
LIDO ISLE COMMUNITY ASSOC.
AVERAGE TOP OF CURB CALCS
ESTABLISHMENT OF GRADE (SITE IS <5% SLOPE)
SURVEY POINTS AT EXISTING BUILDING CORNERS:
12.35' + 12.95' + 12.7' + 12.32' = 50.32' / 4 = 12.58'
AVERAGE TOP OF CURB AT PROPERTY LINE CORNERS:
12.87' + 12.79' = 25.66' / 2 = 12.83'
PROPOSED
RESIDENCE
F.F.=13.61
T/SLAB=13.42
PAD=______
PROPOSED
GARAGE
JOB NO.SHEET
1 3 9 A v e n i d a N a v a r r o
San Cle m ente , CA 9 26 72
9 4 9 .4 9 2 .8 5 8 6
www.toa lengi nee ring.com
C I V I L E N G I NE ER I NG
L A N D S U R V E Y I N G
STORMWATER QUALITY
OF
PLANS PREPARED BY:
PREPARED FOR:
AP
V
D
.
DA
T
E
R
E
V
I
S
I
O
N
S
BY
DA
T
E
APPD.:
DATE:
DWG. NO.
H. SCALE:
V. SCALE:SURVEY DATE:
CHD.:
DRN.:
CAMILLE & JOUMANA RIZKO
224 VIA EBOLI
NEWPORT BEACH, CA 92663
TEL: (818) 288-8847
CALEB RIOS
R.C.E. 57587
DATE:
1/8"=1'
N/A10/27/2020
3/28/2023
M.F.B.
M.F.B.
C.R.
22225 1 1
E1
RI
Z
K
O
R
E
S
I
D
E
N
C
E
LO
T
S
8
4
6
&
P
O
R
.
8
4
5
,
T
R
A
C
T
9
0
7
30
6
V
I
A
L
I
D
O
N
O
R
D
,
N
E
W
P
O
R
T
B
E
A
C
H
,
C
A
CO
N
S
T
R
U
C
T
I
O
N
P
O
L
L
U
T
I
O
N
PR
E
V
E
N
T
I
O
N
P
L
A
N
LEGENDNOTE
EROSION CONTROL BMPs
TEMPORARY SEDIMENT CONTROL
WIND EROSION CONTROL
TRACKING CONTROL
WASTE MANAGEMENT AND MATERIALS POLLUTION CONTROL
NON-STORMWATER MANAGEMENT
YEAR-ROUND BMP REQUIREMENTS
BENCHMARK NOTE:
OCSBM NB3-12-92
ELEV=11.912
NAVD88 DATUM, 2015 ADJ.
EASEMENT NOTE:
THE PLAT FOR THIS SURVEY WAS PREPARED WITHOUT A TITLE REPORT.
UNPLOTTED EASEMENTS MAY EXIST ON THE SUBJECT PROPERTY.
1 A 4' WIDE EASEMENT FOR PUBLIC UTILITY PURPOSES SHOWN AS
DEDICATED AND ACCEPTED ON A MAP OF TRACT 907
JOB NO.SHEET
1 3 9 A v e n i d a N a v a r r o
S a n C le me n t e , C A 9 2 6 7 2
9 4 9 .4 9 2 .8 5 8 6
w w w.to ale n g i n ee rin g .co m
C I V I L E N G I N E E R I N G
L A N D S U R V E Y I N G
ST ORMWATE R Q UA LI TY
OF
PREPARED FOR:
AP
V
D
.
DA
T
E
R
E
V
I
S
I
O
N
S
BY
DA
T
E
APPD.:
DATE:
DWG. NO.
H. SCALE:
V. SCALE:SURVEY DATE:
CHD.:
DRN.:
GERALD AND LYNN
PHARRIS
S
T
A
TE OF CA L I F OR NIA
LICE N S E D LAND SU
R
V
E
Y
ORVIKTOR P.
MEUM
No. 8682
VIKTOR P. MEUM
P.L.S. 8682
DATE:
1/8"=1'
-10-27-20
11-22-20
MSF
-
VM
20211 1 1
TP-01
LO
T
8
4
6
A
N
D
N
W
L
'
Y
1
/
2
O
F
L
O
T
8
4
5
,
T
R
A
C
T
9
0
7
,
A
P
N
4
2
3
-
1
4
4
-
1
4
30
6
V
I
A
L
I
S
O
N
O
R
D
,
N
E
W
P
O
R
T
B
E
A
C
H
,
C
A
L
I
F
O
R
N
I
A
TO
P
O
G
R
A
P
H
I
C
S
U
R
V
E
Y
BOUNDARY NOTE:
SCALE: 1/8"=1'
PROPOSED
RESIDENCE
F.F.=13.61
T/SLAB=13.42
PAD=______
PROPOSED
GARAGE
DISPOSITION NOTES
JOB NO.SHEET
1 3 9 A v e n i d a N a v a r r o
San Cle m en te , CA 92672
9 4 9 .4 9 2 .8 5 8 6
www.toalengineering.com
C I V I L EN G I NE ER I NG
L A N D S U R V E Y I N G
STORMWATER QUALITY
OF
PLANS PREPARED BY:
PREPARED FOR:
AP
V
D
.
DA
T
E
R
E
V
I
S
I
O
N
S
BY
DA
T
E
APPD.:
DATE:
DWG. NO.
H. SCALE:
V. SCALE:SURVEY DATE:
CHD.:
DRN.:
CAMILLE & JOUMANA RIZKO
224 VIA EBOLI
NEWPORT BEACH, CA 92663
TEL: (818) 288-8847
CALEB RIOS
R.C.E. 57587
DATE:
1/8"=1'
N/A10/27/2020
2/15/2023
A.A.
M.B.
C.R.
22225 1 1
C1
RI
Z
K
O
R
E
S
I
D
E
N
C
E
LO
T
S
8
4
6
&
P
O
R
.
8
4
5
,
T
R
A
C
T
9
0
7
30
6
V
I
A
L
I
D
O
N
O
R
D
,
N
E
W
P
O
R
T
B
E
A
C
H
,
C
A
PR
E
L
I
M
I
N
A
R
Y
G
R
A
D
I
N
G
P
L
A
N
ADDITIONAL NOTES
EASEMENT NOTE
BENCH MARK
LEGEND
SCOPE OF WORK
UTILITY NOTES
CITY OF NEWPORT BEACH NOTES
DN
SITE LEGEND
PROPERTY LINE
MINIMUM BUILDING
SETBACK LINE
NOTE:
1. THERE SHALL BE NO TRENCHES OR EXCAVATIONS 5 FEET OR MORE IN
DEPTH INTO WHICH A PERSON IS REQUIRED TO DESCEND; OR OBTAIN A
NECESSARY PERMIT FROM THE STATE OF CALIFORNIA, DIVISION OF
INDUSTRIAL SAFETY PRIOR TO THE ISSUANCE OF A BUILDING OR
GRADING PERMIT.
2. FOR SPECIAL INSPECTION FORMS SEE STRUCTURAL DRAWINGS.
3. VERIFY EXACT SIZE, LOCATIONS AND DEPTH (WHERE APPLICABLE) OF
ALL EXISTING PIPING, LINES, LATERALS, AND WYES BEFORE STARTING
TRENCHING OR ANY OTHER WORK. FIELD VERIFY THAT INVERT
ELEVATIONS ARE SUFFICIENT TO MAINTAIN REQUIRED SLOPES. SHOULD IT
BE NECESSARY TO REROUTE LINES DUE TO CONDITIONS FOUND ON THE
SITE OR IF INDICATED POINT OF CONNECTIONS CAN NOT BE MADE TO
THE LINES AS FOUND, THE CONTRACTOR SHALL, BEFORE CONTINUING,
NOTIFY THE ARCHITECT PRIOR TO INSTALLING ANY WORK WHICH MAY BE
AFFECTED.
4. THE SEWER LINES ARE PRESENTED DIAGRAMMATICLY TO THE EXTENT
THAT ALL OFFSETS, BENDS, SPECIAL FITTINGS AND EXACT LOCATIONS
ARE NOT INDICATED. LOCATION OF PIPING MAY VARY AS LONG AS
INDICATED PIPE SIZES ARE INSTALLED. INSTALL PIPING IN AVAILABLE
LOCATIONS. REFER TO PLUMBING DRAWINGS FOR MORE INFORMATION.
FIRE HYDRANT
WATER VALVE
FH
WV
SITE PLAN NOTES
1. DO NOT SCALE DRAWINGS.
2. THIS ARCHITECTURAL SITE PLAN IS INTENDED FOR BUILDING SETBACK
PURPOSES AND LOCATION OF UTILITIES ONLY. SEPARATE DRAWING
SUBMITTAL(S) AND PERMIT(S) IS/ARE REQUIRED FOR THE GRADING
PLAN, LANDSCAPE AND IRRIGATION PLAN, SWIMMING POOL AND SPA,
POOL AND SPA MECHANICAL EQUIPMENT, ANY SITE RETAINING WALLS
OVER 4 FEET HIGH FROM THE BOTTOM OF THE FOUNDATION TO TOP OF
WALL, ANY PROPERTY LINE FENCE/ WALL/ PILASTER OVER 6'-0" IN
HEIGHT, DETACHED PATIO COVERS, TRELLISES, ACCESSORY
BUILDING(S) . . .ETC.
3. REFER TO THE ARCHITECTURAL FLOOR PLANS AND GENERAL NOTES
FOR ADDITIONAL REQUIRED INFORMATION.
4. REFER TO THE GEOTECHNICAL SOILS REPORT FOR GRADING,
FOUNDATION, AND BACKFILL REQUIREMENTS.
5. REFER TO CIVIL DRAWINGS FOR EXACT PROPERTY LINE DIMENSIONS,
LOCATION(S) OF EXISTING CURB AND GUTTER, UTILITY EASEMENT(S),
TOPOGRAPHY, PRECISE GRADING PLAN, EROSION CONTROL PLAN, TOP
OF WALL HEIGHTS, PAD AND FLOOR ELEVATIONS, SITE DRAINAGE,
LOCATION(S) OF BACKWATER VALVES, LOCATION AND DIRECTION OF
FLOW OF THE STORM AND SEWER CONNECTIONS, LOCATION OF NATURAL
GAS AND WATER METERS, LOCATION OF RETAINING WALLS. . . ETC.
6. REFER TO THE MECHANICAL, PLUMBING AND ELECTRICAL PLANS FOR
LOCATION(S) OF ALL UTILITIES AND MECHANICAL EQUIPMENT NOT SHOW
ON THE SITE PLAN.
7. EXISTING SEWER COLLECTION, WATER, AND GAS DISTRIBUTION ARE
PUBLIC SYSTEMS.
8. PRE-CONSTRUCTION MEETING REQUIREMENTS:
• GENERAL CONTRACTOR SHALL SCHEDULE A PRE-CONSTRUCTION
MEETING WITH THE COUNTY INSPECTOR, ARCHITECT, GEOTECHNICAL
ENGINEER, CIVIL ENGINEER AND GRADING CONTRACTOR AT THE SITE
PRIOR TO THE START OF GRADING. CONTACT COUNTY OF ORANGE
RESIDENTIAL INSPECTION SUPERVISOR.
9. GENERAL CONTRACTOR IS TO PROVIDE THE LOCAL AGENCY HAVING
JURISDICTION OVER THE PROJECT A "WILL SERVE" LETTER AND/OR
"SERVICE WORK ORDER" FROM THE SERVING WATER, GAS, AND
ELECTRIC COMPANY(S). THE NATURAL GAS SUPPLIER SHALL ALSO
STATE THE LOCATION OF THE GAS METER AND AVAILABILITY OF THE
DESIRED PRESSURE PRIOR TO THE START OF CONSTRUCTION.
10. THERE SHALL BE NO TRENCHES OR EXCAVATIONS 5 FEET OR MORE IN
DEPTH INTO WHICH A PERSON IS REQUIRED TO DESCEND; OR OBTAIN A
NECESSARY PERMIT FROM STATE OF CALIFORNIA, DIVISION OF
INDUSTRIAL SAFETY AND CAL/OSHA PRIOR TO THE ISSUANCE OF A
BUILDING OR GRADING PERMIT.
11. REFER TO STRUCTURAL DRAWINGS FOR ALL SITE RETAINING WALL
INFORMATION, ALONG WITH STRUCTURAL OBSERVATION, AND SPECIAL
INSPECTION CERTIFICATION REQUIREMENTS BY LICENSED
PROFESSIONALS WHICH ARE REQUIRED FOR CONSTRUCTION OF ALL NEW
BUILDINGS PER THE REQUIREMENTS OF THE COUNTY OF ORANGE.
12. FINISH GRADE AROUND THE NEW STRUCTURE SHALL BE SLOPED AWAY
FROM THE BUILDING FOR DRAINAGE PURPOSES. SURFACE DRAINAGE
SHALL BE DIVERTED TO A STORM SEWER CONVEYANCE OR OTHER
APPROVED POINT OF COLLECTION THAT DOES NOT CREATE A HAZARD.
LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM
FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6 INCHES
WITHIN THE FIRST 10 FEET (5%). WHERE LOT LINES, WALLS, SLOPES OR
OTHER PHYSICAL BARRIERS PROHIBIT 6 INCHES OF FALL WITHIN 10 FEET,
DRAINS OR SWALES SHALL BE CONSTRUCTED TO ENSURE DRAINAGE
AWAY FROM THE STRUCTURE. IMPERVIOUS SURFACES WITHIN 10 FEET OF
THE BUILDING FOUNDATION SHALL BE SLOPED A MINIMUM OF 2% AWAY
FROM THE BUILDING, PER C.R.C. SECTION R401.3. ALL WATER SUPPLY
LINES TO THE HOUSE SHALL BE NO LESS THAN 1-1/2".
13. MINIMUM SLOPE OF SEWER LINE AND DRAINAGE PIPING IS 2% PER C.P.C.
SECTION 708.
14. PRIOR TO THE RELEASE OF THE FOOTING INSPECTION, THE APPLICANT
SHALL SUBMIT CERTIFICATION, BY SURVEY OR OTHER APPROPRIATE
METHOD, THAT THE STRUCTURES WILL BE CONSTRUCTED IN COMPLIANCE
WITH THE DIMENSIONS SHOWN AND IN COMPLIANCE WITH THE SETBACKS
OF THE APPLICABLE COMMUNITY ASSOCIATION GUIDELINES AND LOCAL
ZONING CODE.
15. AN APPROVED BACKWATER VALVE IS REQUIRED FOR DRAINAGE PIPING
SERVING FIXTURES LOCATED BELOW THE ELEVATION OF THE NEXT
UPSTREAM MANHOLE COVER. FIXTURES ABOVE SUCH ELEVATION SHALL
NOT DISCHARGE THROUGH THE BACKWATER VALVE. CLEAN OUTS FOR
DRAINS THAT PASS THROUGH A BACK WATER VALVE SHALL BE CLEARLY
IDENTIFIED WITH A PERMANENT LABEL STATING "BACKWATER VALVE
DOWNSTREAM" PER C.P.C. SECTION 710.1.
16. THE DISCHARGE OF POLLUTANTS TO ANY STORM DRAINAGE SYSTEM IS
PROHIBITED. NO SOLID WASTE, PETROLEUM BYPRODUCTS, SOIL
PARTICULATE, CONSTRUCTION WASTE MATERIALS, OR WASTEWATER
GENERATED ON CONSTRUCTION SITES OR BY CONSTRUCTION ACTIVITIES
SHALL BE PLACED, CONVEYED OR DISCHARGED INTO THE STREET,
GUTTER OR STORM DRAIN SYSTEM.
17. ALL LIGHTING IS TO BE INSTALLED AND ADJUSTED SO AS TO PRECLUDE
LIGHT SPILL ONTO ADJACENT PROPERTIES. UPLIGHTS WITHIN 10' OF
PROPERTY LINES ARE TO BE DIRECTED STRAIGHT UPWARD.
18. LIGHTING SHALL BE DESIGNED SO THAT ALL DIRECT RAYS ARE
CONFINED TO THE SITE AND THAT ADJACENT RESIDENCES ARE
PROTECTED FROM SUBSTANTIAL LIGHT AND GLARE.
19. BUILDING ADDRESS SHALL BE PROVIDED ON THE BUILDING IN SUCH A
POSITION AS TO BE PLAINLY VISIBLE AND LEGIBLE FROM THE STREET
AND TO BE A MINIMUM OF 4" HIGH X 1" WIDE NONCOMBUSTIBLE,
CONTRASTING MATERIALS OR PER COUNTY AND O.C.F.A.
REQUIREMENTS.DOORS THAT PROVIDE DIRECT ACCESS TO THE
SWIMMING POOL SHALL BE PROVIDED WITH A BARRIER COMPLIANT WITH
STATE AND LOCAL POOL BARRIER ORDINANCE. THE MOST STRINGENT
CODE REQUIREMENT SHALL PREVAIL.
20. PRIOR TO AN ISSUANCE OF A COUNTY BUILDING PERMIT, THE APPLICANT
MUST OBTAIN A SEPARATE RESIDENTIAL SITE PLAN REVIEW AND
APPROVAL BY THE ORANGE COUNTY FIRE AUTHORITY (O.C.F.A).
21. SEPARATE DRAWING SUBMITTAL(S) AND PERMIT(S) IS/ARE REQUIRED BY
THE OCFA, FOR THE N.F.P.A. 13-D AUTOMATIC FIRE SPRINKLER SYSTEM.
THE SYSTEM SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH
N.F.P.A. 13-D AND AMENDMENTS AS ADOPTED BY THE LOCAL
JURISDICTION. PLANS SHALL BE SUBMITTED AND APPROVED BY THE
ORANGE COUNTY FIRE AUTHORITY (O.C.F.A) FIRE CHIEF OR DESIGNATED
REPRESENTATIVE PRIOR TO INSTALLATION. THE SYSTEM SHALL BE
OPERATIONAL PRIOR TO THE ISSUANCE OF A CERTIFICATE OF USE AND
OCCUPANCY FOR ALL ONSITE STRUCTURES.
22. N.F.P.A. 13-D AUTOMATIC FIRE SPRINKLER SHALL BE INSTALLED AND
ENHANCED TO INCLUDE COVERAGE OF FOYERS, ALL BATHROOMS AND
CLOSETS.
23. ALL FLAMMABLE VEGETATION SHALL BE REMOVED FROM EACH
BUILDING SITE FOR A MINIMUM DISTANCE OF THIRTY FEET 30 FEET FROM
ANY FLAMMABLE BUILDING MATERIAL INCLUDING ALL STRUCTURES.
24. SEE SHEET GN-3.0 FOR O.C.F.A. NOTES.
0 FT FYSB (NEWPORT BAY)
X
GFF: 12.9'
X
T.O. SLAB: 13.42'
FIN. FL.: 13.61'X
FI
N
.
S
U
R
F
A
C
E
A
T
S
T
O
R
A
G
E
:
9.
0
2
'
FIN. SURFACE AT BAYFRONT (9.02')
EA
V
E
T
O
P
L
3'-
0
"
EAVE TO PL
3'-1 3/8"
EAVE ON PL
EAVE TO PL
4'-0"
P R O P E R T Y L I N E : 9 0 . 0 0 '
P R O P E R T Y L I N E : 9 0 . 0 0 '
P
R
O
P
E
R
T
Y
L
I
N
E
:
4
5
.
0
0
'
P
R
O
P
E
R
T
Y
L
I
N
E
:
4
5
.
0
0
'
B
E
A
C
H
V
I
A
L
I
D
O
N
O
R
D
OUTLINE OF 1ST FLOOR
OUTLINE OF 2ND FLOOR
2ND FLOOR BALCONY
1ST FLOOR TERRACE
BOAT STORAGE AT GRADE
OUTLINE OF ROOF EAVE
OUTLINE OF ROOF EAVE OVER ENTRY
N E W 2 - S T O R Y
S F D
GATE AND FENCE/WALL (MAX. 5FT ABV. GRADE)TRASH/RECYCLE BINS
GAS METER
WATER METER
GATE AND FENCE/WALL (MAX. 5FT ABV. GRADE)
HARDSCAPE (SEE CIVIL DWGs)
HARDSCAPE
HA
R
D
S
C
A
P
E
/
D
R
I
V
E
W
A
Y
PL
A
N
T
E
R
PL
A
N
T
E
R
PLANTER
AREA
AC CONSENSER LOCATIONS (TBD)
ARCHITECTURAL PROJECTION
AT 2ND FLR BALCONY CURB
TYP.
3"
ARCHITECTURAL PROJECTION
AT 2ND FLR BALCONY CURB
EAVE AT CHIMNEY
MAX
1'-0"
CHIMNEY
CHIMNEY PROJECTION
7'-8"
EXISTING PROPERTY LINE WALL
EXISTING PROPERTY LINE WALL NEW GATE
SYSB
4'-0"
SYSB
4'-0"
FYSB
4'-0"
VIA LIDO
LICENCE STAMP:
THESE DRAWINGS ARE THE PROPERTY OF OATMAN
ARCHITECTS AND SHALL NOT BE MODIFIED OR USED ON ANY
OTHER PROJECT OR SITE WITHOUT WRITTEN PERMISSION.
IT IS THE OWNER'S AND IT'S GENERAL CONTRACTOR'S
RESPONSIBILITY, PRIOR TO OR DURING CONSTRUCTION, TO
NOTIFY THE ARCHITECT IN WRITING OF ANY PERCEIVED
ERRORS OR OMISSIONS IN THE PLANS AND/ OR GENERAL
NOTES OF WHICH A CONTRACTOR THOROUGHLY
KNOWLEDGEABLE WITH THE BUILDING CODES AND MEANS &
METHODS OF CONSTRUCTION SHOULD REASONABLY BE
AWARE. WRITTEN INSTRUCTIONS ADDRESSING SUCH
PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED
FROM THE ARCHITECT PRIOR TO THE OWNER OR OWNER'S
CONTRACTOR PROCEEDING WITH THE WORK. THE OWNER
WILL BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION
IF THESE PROCEDURES ARE NOT FOLLOWED.
NOTE: THE ORIGINAL SIZE OF THIS DRAWING SHEET IS: 36"X48"
PROJECT NUMBER:
SUBMITTAL:
REVISION:
DATE DESCRIPTION
PERMIT NUMBER:
CLIENT:
4/11/2023 1:54:56 PM
A1.0
ARCHITECTURAL
SITE PLAN
2022001
RI
Z
K
O
R
E
S
I
D
E
N
C
E
30
6
V
I
A
L
I
D
O
N
O
R
D
NE
W
P
O
R
T
B
E
A
C
H
,
C
A
9
2
6
6
3
DE
S
I
G
N
D
E
V
E
L
O
P
M
E
N
T
CAMILLE AND JOUMANA RIZKO
PRINCIPAL: HOMER
OATMAN
DRAWN BY: Author
NO. DATE DESCRIPTION
1/4" = 1'-0"1ARCHITECTURAL SITE PLAN NORTH (REF)
C O M P A S S
N O R T H
SLAB PLAN NOTES
1. THIS PLAN IS FOR REFERENCE ONLY.
2. COMPARE AND VERIFY SLAB ELEVATIONS VARIATIONS AS
SHOWN ON THE BASEMENT AND FIRST FLOOR PLANS PRIOR TO
AND DURING CONSTRUCTIONS.
3. COMPARE AND VERIFY ALL DIMESIONS AS SHOWN ON THE
BASEMENT AND FIRST FLOOR PLANS PRIOR TO AND DURING
CONSTRUCTIONS.
4. COMPARE AND VERIFY ALL EXTERIOR WALL THICKNESS AND
EXTERIOR DOOR ROUGH OPENING SIZES IN RELATION TO THE
END OF SLAB AND PERIMETER CURB PRIOR TO CONSTRUCTION.
5. COMPARE AND VERIFY ALL EXTERIOR DOOR DEPRESSIONS IN
RELATION TO EXTERIOR DOOR ROUGH OPENING SIZES PER
MANUFACTURER'S SPECIFICATIONS PRIOR TO CONSTRUCTION.
6. COMPARE AND VERIFY ALL HARDSCPE CONDITIONS IN RELATION
TO THE ENDE OF SLAB AND PERIMETER CURB PRIOR TO
CONSTRUCTION.
7. ANY DEVIATIONS OR DISCREPANCIES SHALL BE FORWARDED TO
THE ARCHITECT.
SLAB PLAN LEGEND
NEW 6" X 6" CONC. CURB,
U.N.O.
POURED CONC. SLAB, SEE
STRUCT.
DEPRESSED SLAB AREA
AND DEPTH DIMENSION
1
1
/
2
"
T.O.S. 13.10'
VERIFY W/
ELEV. MANUF.
VERIFY W/ ELEV. MANUF.
6'-0"
VERIFY W/ ELEV. MANUF.
5'-3 1/2"
1/2"
3-CAR
GARAGE
1/4" PER FOOT
SLOPE
4"
3'-0"
5'-2"
3"
DN. 2"
1-
1
/
2
"
MA
X
.
1-
1
/
2
"
MA
X
.
6"
6"
M
I
N
.
6"
6"
M
I
N
.
1-1/2"
3/4"
SLOPE
PER CIVIL
SL
O
P
E
PE
R
C
I
V
I
L
SL
O
P
E
PE
R
C
I
V
I
L
6"6"
6"
6'-11 3/8"
22'-2"
1 1/4"
1'-0"
1'-0"
HIGH POINT
18'-3 3/4"
18'-3 3/4"
6"
6"
4'-2 1/4"
27'-8"
3'-6 5/8"
4'-3 3/4"
4'-2 1/4"36'-4 3/4"39'-3"10'-2"
5'-3 1/2"
1/2"
18'-0 7/8"
2'-1 1/8"6"
6" MIN.
1'-1 1/4"
6"6"
6"
6" MIN.
6" MIN.
6"
6"
6"
M
I
N
.
4'-2 1/4"17'-0 1/2"3'-2"2'-7 3/4"2'-8 1/2"2'-10"15'-7 1/2"2'-10"28'-9 1/2"10'-2"
6"6"
6"
M
I
N
.
3'-2"
8"
15'-1 3/4"
2'-2 1/4"
6"
6"
M
I
N
.
6" MIN.
6"
6"
4'-2 1/4"
4'-8 3/4"
13'-7"
13'-7"
4'-8 3/4"
4'-2 1/4"
6"
6"
6"
6"
FLOW
LINE/CURB
CUT
12.42'
4'-9 1/2"20'-1 1/4"
GAR. FIN. FL.: 12.90
GAR. FIN. FL.: 13.32
GAR. FIN. FL.: 13.34
SLOPE
PER CIVIL
ALIGN FINISHES
FIN. FL.: 13.61
GAR. FIN. FL.: 13.25
1-
1
/
2
"
MA
X
.
FIN. FL.: 13.61
FIN. FL.: 13.61
FIN. FL.: 13.61 FIN. FL.: 13.61
LICENCE STAMP:
THESE DRAWINGS ARE THE PROPERTY OF OATMAN
ARCHITECTS AND SHALL NOT BE MODIFIED OR USED ON ANY
OTHER PROJECT OR SITE WITHOUT WRITTEN PERMISSION.
IT IS THE OWNER'S AND IT'S GENERAL CONTRACTOR'S
RESPONSIBILITY, PRIOR TO OR DURING CONSTRUCTION, TO
NOTIFY THE ARCHITECT IN WRITING OF ANY PERCEIVED
ERRORS OR OMISSIONS IN THE PLANS AND/ OR GENERAL
NOTES OF WHICH A CONTRACTOR THOROUGHLY
KNOWLEDGEABLE WITH THE BUILDING CODES AND MEANS &
METHODS OF CONSTRUCTION SHOULD REASONABLY BE
AWARE. WRITTEN INSTRUCTIONS ADDRESSING SUCH
PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED
FROM THE ARCHITECT PRIOR TO THE OWNER OR OWNER'S
CONTRACTOR PROCEEDING WITH THE WORK. THE OWNER
WILL BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION
IF THESE PROCEDURES ARE NOT FOLLOWED.
NOTE: THE ORIGINAL SIZE OF THIS DRAWING SHEET IS: 36"X48"
PROJECT NUMBER:
SUBMITTAL:
REVISION:
DATE DESCRIPTION
PERMIT NUMBER:
CLIENT:
4/11/2023 1:54:57 PM
A2.0
SLAB PLAN
2022001
RI
Z
K
O
R
E
S
I
D
E
N
C
E
30
6
V
I
A
L
I
D
O
N
O
R
D
NE
W
P
O
R
T
B
E
A
C
H
,
C
A
9
2
6
6
3
DE
S
I
G
N
D
E
V
E
L
O
P
M
E
N
T
CAMILLE AND JOUMANA RIZKO
PRINCIPAL: HOMER
OATMAN
DRAWN BY: Author
NO. DATE DESCRIPTION
1/4" = 1'-0"1SLAB PLAN
P R O P E R T Y L I N E : 9 0 . 0 0 '
P R O P E R T Y L I N E : 9 0 . 0 0 '
P
R
O
P
E
R
T
Y
L
I
N
E
:
4
5
.
0
0
'
P
R
O
P
E
R
T
Y
L
I
N
E
:
4
5
.
0
0
'
B
E
A
C
H
V
I
A
L
I
D
O
N
O
R
D
SYSB
4'-0"
FYSB
4'-0"
SYSB
4'-0"
VIA LIDO
0 FT FYSB (NEWPORT BAY)
DEMOLISH EXISTING
2-STORY DWELLING
WITH ATTACHED
3-CAR GARAGE
(5,351 SF)
DEMOLITION NOTES
1. DO NOT SCALE DRAWING.
2. SITE TO BE FENCED AT A HEIGHT BETWEEN 72 AND 84 INCHES USING A
CHAIN LINK OVERLAID ON THE EXTERIOR WITH AN OPAQUE VINYL PENCE.
3. ALL DEBRIS SHALL BE WET AT TIME OF HANDLING TO PREVENT DUST.
4. SEWER LINE SHALL BE CAPPED.
5. STREETS AND SIDEWALKS ARE TO REMAIN CLEAN AND FREE OF ANY
OBSTRUCTIONS.
6. PEDESTRIAN CANOPY PROTECTION REQUIRED IF DEMOLITION IS WITHIN 10
FEET OF PUBLIC SIDEWALK.
7. EROSION CONTROL:
A. EROSION CONTROL DEVICES SHALL BE AVAILABLE ON-SITE BETWEEN
OCTOBER 15 AND MAY 15.
B. BETWEEN OCTOBER 15 AND MAY 15, EROSION CONTROL MEASURES
SHALL BE IN PLACE AT THE END OF EACH WORKING DAY WHENEVER
THE FIVE-DAY PROBABILITY OF RAIN EXCEEDS 30 PERCENT. DURING
THE REMAINDER OF THE YEAR, THEY SHALL BE IN PLACE AT THE END
OF THE WORKING DAY, WHENEVER THE DAILY RAINFALL PROBABILITY
EXCEEDS 50 PERCENT.
C. TEMPORARY DE-SILTING BASINS, WHEN REQUIRED, SHALL BE
INSTALLED AND MAINTAINED FOR THE DURATION OF THE PROJECT.
8. THE ARCHITECT AND ARCHITECTS CONSULTANTS ARE NOT RESPONSIBLE
FOR THE DISCOVERY, PRESENCE, HANDLING REMOVAL, OR DISPOSAL
OF HAZARDOUS MATERIALS OR PERSONS EXPOSED TO HAZARDOUS
MATERIALS IN ANY FORM AT THE PROJECT SITE.
9. CONTACT ARCHITECT FOR ANY QUESTIONS PRIOR TO DEMOLITION
START.
10. CONTACT "DIGALERT" FOR ANY QUESTIONS PRIOR TO DEMOLITION
START.
11. PRIOR TO DEMOLITION, CAP ALL NECESSARY UTILITIES IN A SAFE MINER
BASED ON SCOPE OF WORK.
12. PRIOR TO ANY DEMOLITION, DISCUSS WITH THE OWNER THE OPTION OF
SAVING ANY EXISTING FIXTURES, FAUCETS, ELECTRICAL FIXTURES,
CABINETS, DOORS, WINDOWS, ETC. FOR PERSONAL USE OR DONATION.
13. DECONSTRUCTION/DEMOLITION PHASE WITH THE CLIENT FOR ANY
MATERIALS TO BE DONATED.
14. DEMOLITION BEYOND THE APPROVED SCOPE OF WORK REQUIRES
PLANNING DIVISION APPROVAL PRIOR TO COMMENCEMENT OF WORK.
APPROVAL OF REVISIONS TO PROJECT PLANS ARE NOT GUARANTEED.
ANY CHANGES IN THE CURRENT SCOPE OF WORK MAY REQUIRE A
COASTAL DEVELOPMENT PERMIT AND THE ENTIRE STRUCTURE TO BE
DEMOLISHED AND REDEVELOPED IN CONFORMANCE WITH THE CURRENT
ZONING CODE DEVELOPMENT STANDARDS AND LOCAL COASTAL
PROGRAM.
LICENCE STAMP:
THESE DRAWINGS ARE THE PROPERTY OF OATMAN
ARCHITECTS AND SHALL NOT BE MODIFIED OR USED ON ANY
OTHER PROJECT OR SITE WITHOUT WRITTEN PERMISSION.
IT IS THE OWNER'S AND IT'S GENERAL CONTRACTOR'S
RESPONSIBILITY, PRIOR TO OR DURING CONSTRUCTION, TO
NOTIFY THE ARCHITECT IN WRITING OF ANY PERCEIVED
ERRORS OR OMISSIONS IN THE PLANS AND/ OR GENERAL
NOTES OF WHICH A CONTRACTOR THOROUGHLY
KNOWLEDGEABLE WITH THE BUILDING CODES AND MEANS &
METHODS OF CONSTRUCTION SHOULD REASONABLY BE
AWARE. WRITTEN INSTRUCTIONS ADDRESSING SUCH
PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED
FROM THE ARCHITECT PRIOR TO THE OWNER OR OWNER'S
CONTRACTOR PROCEEDING WITH THE WORK. THE OWNER
WILL BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION
IF THESE PROCEDURES ARE NOT FOLLOWED.
NOTE: THE ORIGINAL SIZE OF THIS DRAWING SHEET IS: 36"X48"
PROJECT NUMBER:
SUBMITTAL:
REVISION:
DATE DESCRIPTION
PERMIT NUMBER:
CLIENT:
4/11/2023 1:54:58 PM
A3.0
DEMOLITION
PLAN
2022001
RI
Z
K
O
R
E
S
I
D
E
N
C
E
30
6
V
I
A
L
I
D
O
N
O
R
D
NE
W
P
O
R
T
B
E
A
C
H
,
C
A
9
2
6
6
3
DE
S
I
G
N
D
E
V
E
L
O
P
M
E
N
T
CAMILLE AND JOUMANA RIZKO
PRINCIPAL: HOMER
OATMAN
DRAWN BY: Author
NO. DATE DESCRIPTION
1/4" = 1'-0"1DEMOLITION PLAN
UP
DN
DN
DN
FLOOR PLAN LEGEND
NEW 2x6 WOOD STUD WALLS
NEW CONC. WALL, REFER
TO STRUCTURAL
NEW 2x4 WOOD STUD WALLS
1A
1
DOOR TAG
WINDOW TAG
KEYNOTE
ELEVATION CALLOUT
SECTION CALLOUT
A101
1
1
1
1
101
1
A101
SIM
1HR FIRE RATED
EGRESS SYMBOL
TEMPERED GLAZING
CURTAIN WALL TAG1AA
KEYNOTES
2
A6.1
2
A6.0
1
A6.0
CLEAR
30'-0"
CLEAR
20'-0"
(20'-0" X 30'-0)
3-CAR GARAGE
ENTRY
(12'-0" X 14'-0")
GUEST BEDROOM 2
(8'-0" X 14'-0")
BACK
KITCHEN/PANTRY
ELEV.(8'-6" X 5'-6")
POWDER
(5'-2" X 10'-0")
BA.2
(5'-2" X 4'-9")
CL.2
3'-0"
(12'-3" X 20'-5")
KITCHEN
(11'-8" X 20'-5")
DINING ROOM
(37'-6" X 15'-4")
GREAT ROOM
TERRACE
DW
OVEN30"
REFBCR
5/8" TYPE 'X'
FLAT CEILING
(+9'-0)
FLAT CEILING
(+9'-0)
FLAT
CEILING
(+9'-0)
FLAT CEILING
(+10'-0)
FLAT CEILING
(+10'-0)
FLAT CEILING
(+10'-0)
FLAT CEILING
(+10'-0)
FLAT CEILING (+10'-0)
FLAT
CEILING
(+10'-0)
FLAT CEILING
(+10'-0)
VAULTED
CEILING
19R
@
7.14"
SYSB
4'-0"
3'-8"
ZERO FYSB
FIN. FL.: 13.61
A6.23 1
2
4
A6.2 6
5A6.4
1
A6.2 8
2
3
7
A6.33
2
1
4
2
A7.0
2
A7.0
CLR
4'-6"
18"
FRZ COFFEE
FIXTURE
ALIGNMENT
CENTERLINE
DW
36"
REF
30" GAS
RANGE
30" ELEC
COOKTOP
STONE VENEER
6'-0"
101
102
103 104 105
106107
108
111
112
113 110
109
1A 1B
4'-2 3/4"
3'-5 1/2"
7'-8 5/8"
1'-0"
15'-5 3/8"
3'-6 1/8"
4'-3 1/8"
5'-4 5/8"
3'-10 3/8"
3'-10 3/8"
7'-8 5/8"
7'-8 5/8"
4'-2 3/4"36'-4 3/4"22'-9 3/4"7'-5 1/4"7'-3 3/8"1'-7 5/8"10'-2 1/2"
22'-10 1/4"5'-7 1/2"12'-5 1/2"8'-5 3/8"24'-6 1/2"1'-7 5/8"
STONE VENEER
23'-0 3/4"
18'-7"4'-3 1/4"4'-1"
1'-6 1/2"
2'-5 1/2"8'-0"2'-0"4'-5 1/2"3'-11 7/8"
2'-2 1/2"
15'-7 3/4"
2'-7 3/4"5'-7 1/2"5'-3 1/2"5'-6"3'-5 1/2"6'-8"
2'-5"2'-10 1/2"3'-1 1/4"3'-6 3/4"
8 3/4"
3'-9 1/2"
2'-2"
OPENING
3'-0"
℄
10'-0"
4'-0"
2'-0"
2'-0"
3'-0"
7'-0"
2'-6 1/2"
CLEAR
4'-6"
EQ
EQ
4'-2 3/4"
4'-8 1/4"
27'-2"
4'-8 1/4"
4'-2 3/4"
EQ
EQ
1AA
1BB
1
A7.1
1
A7.1
3 1/4"
CLR
7'-8"
1'-1 3/8"
1'-8 3/4"
70" DIRECT VENT
LINEAR FIREPLACE
MANUFACTURER TBD
(ANSIZ21.88/CSA2.33a)
2
A7.1
2
A7.1
1
A7.0
1
A7.0
20'-1 1/4"
18'-0"
GAR. FIN. FL.: 12.90
FIN. FL.: 13.61
FIN. FL.: 13.61GAR. FIN. FL.: 13.26
FIN. FL.: 13.61
FIN. FL.: 13.61
FIN. FL.: 13.61GAR. FIN. FL.: 13.32
2
A6.1
2
A6.0
1
A6.0
1
A6.1(11'-5" X 5'-3")
BATH 5
(13'-0" X 12'-0")
BEDROOM 4
(13'-0" X 12'-0")
BEDROOM 5
VAULTED CEILING
VAULTED
CEILING
ELEV.
(10'-2" X 5'-3")
BA.4
(10'-2" X 5'-3")
BA.3
(6'-0" X 5'-0")
CL.4
(6'-0" X 5'-0")
CL.3
(13'-0" X 12'-0")
BEDROOM 3
OUTLINE OF SOFFIT
(ABOVE)
STAIR
VAULTED CEILING
(13'-6" X 15'-4")
OFFICE/DEN (8'-11" X 9'-9")
LAUNDRY
(17'-6" X 17'-0")
PRIMARY BEDROOM
(12'-0" X 9'-8")
PRIMARY BATH
(5'-6" X 3'-11")
P.TOILET
(6'-0" X 7'-5")
P.SHOWER
(15'-0" X 20'-0")
PRIMARY WIC
FLAT CEILING
(+9'-0")
ROOF OVER
ENTRY (BELOW)
CL
.
5
FL
A
T
C
E
I
L
I
N
G
(+
8
'
-
6
"
)
REAR
BALCONY
6'-1 1/2"
FR
O
N
T
D
E
C
K
MECHANICAL
CHASE
19R
@
7.14"
A6.33
2
1
4
A6.6
3
A6.6
7
A6.6 A6.6
9
A6.7
A6.5
5A6.7
A6.7
6
A6.7
12
A6.4
5
3
4
A6.5 8
9
5 7
4
9
10
11
6
2
1
11
12
10
8
5
6
4
1
2
A6.5
11
10
A6.5 2
1
4
3
78 2
A7.0
2
A7.0
4'-0"
201
203
202
204
206
208
209
211
210
212
214
213
215
216
217
218
4'-2 3/4"
12'-11"
2'-6 1/8"
3'-2 3/8"
12'-5 7/8"
5'-5 1/4"
4'-2 3/4"
5'-2 1/2"
7'-8 1/2"
1'-3 3/8"
1'-10 7/8"
7'-8 3/4"
4'-9 1/8"
3'-6"5'-4 3/8"13'-6 3/8"2'-6"15'-8 3/4"14'-0 7/8"9'-5 3/4"18'-1 1/2"1'-7"6'-1 3/8"
2'-5 1/2"11'-0 7/8"7'-3 1/8"6'-9 5/8"4'-11 5/8"4'-6 1/8"3'-11 1/2"10'-6"3'-8"
4'-3 7/8"
4'-1 7/8"
2'-1 1/2"3'-3"6'-6 1/8"2'-3 3/4"
1'-10 1/4"
1'-10 1/2"2'-5 1/2"
4'-5 3/4"
11 3/8"
13'-5 1/2"2'-3 3/4"
1'-10 1/4"
3'-6"3'-9 3/8"13'-5 1/2"10'-7 7/8"10'-7 7/8"13'-5 1/2"15'-5 3/8"6'-0 1/8"6'-11"6'-1 3/8"
2'-5 1/2"9'-0"2'-0"6'-4 1/4"4'-3 5/8"4'-9 1/8"5'-10 3/4"2'-1 1/2"9'-8"1'-8"4'-2 7/8"7'-5 3/8"3'-9 1/4"4'-3 3/8"1'-8 3/4"
2'-9 3/8"
1'-9 3/8"
4'-1 1/2"
1'-10 1/4"
2'-3 3/4"13'-0"
1'-9 3/8"
4'-1 1/2"
11 3/8"
1'-2 7/8"
2'-0"
5'-11 1/2"
3'-6 3/4"
3'-1 1/4"
1'-10 5/8"6'-5"4'-3 1/4"
5 1/2"6 5/8"
3'-0"1'-0 1/8"4'-6 1/8"1'-1 1/8"3'-0"2'-5 7/8"
7'-2 3/4"
10'-6 3/4"
4'-2 3/4"
18'-7 5/8"
13'-5"
4'-5 3/4"
4'-2 3/4"
7'-5 1/8"
11'-2 1/2"
6'-6 3/4"
6'-10 1/4"
3'-5 1/2"
4'-3 1/4"
1'-1 5/8"
4'-4"2'-8 5/8"
11"
2AA
2BB
2CC6'-4 1/4"
2B
2A
2P 2N 2K 2J
2L2M
2Q
2C 2D 2E
2F2H2G1
A7.1
1
A7.1
2DD
2EE
ABOVE
ABOVE
8'-5 5/8"
4"
CLEAR
3'-6"
10 3/4"
3'-9 1/4"R: 2'-11 1/4"3 1/4"
3 1/4"
2
A7.1
2
A7.1
1
A7.0
1
A7.0
3'-6"
3'-6"
45" DIRECT VENT
LINEAR FIREPLACE
MANUFACTURER TBD
(ANSIZ21.88/CSA2.33a)
4'-0"
205
15'-2 1/2"
CLEAR
9'-2 1/4"
4'-0"
8"
9'-10"
16'-0"
9'-10"
4'-8"
8"9'-10 1/4"3"
BOAT STORAGE
(8'-11 1/4" X 35'-8")
CLEAR
35'-8"
FLAT CEILING
(+3'-6)
SL
I
D
I
N
G
D
O
O
R
S
Y
S
T
E
M
001
EQ
EQ
1/4" PER FOOT
SLOPE
1/
4
"
P
E
R
F
O
O
T
SL
O
P
E
1/
4
"
P
E
R
F
O
O
T
SL
O
P
E
FIN. SURF.: 9.01
FIN. SURF.: 9.21
LICENCE STAMP:
THESE DRAWINGS ARE THE PROPERTY OF OATMAN
ARCHITECTS AND SHALL NOT BE MODIFIED OR USED ON ANY
OTHER PROJECT OR SITE WITHOUT WRITTEN PERMISSION.
IT IS THE OWNER'S AND IT'S GENERAL CONTRACTOR'S
RESPONSIBILITY, PRIOR TO OR DURING CONSTRUCTION, TO
NOTIFY THE ARCHITECT IN WRITING OF ANY PERCEIVED
ERRORS OR OMISSIONS IN THE PLANS AND/ OR GENERAL
NOTES OF WHICH A CONTRACTOR THOROUGHLY
KNOWLEDGEABLE WITH THE BUILDING CODES AND MEANS &
METHODS OF CONSTRUCTION SHOULD REASONABLY BE
AWARE. WRITTEN INSTRUCTIONS ADDRESSING SUCH
PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED
FROM THE ARCHITECT PRIOR TO THE OWNER OR OWNER'S
CONTRACTOR PROCEEDING WITH THE WORK. THE OWNER
WILL BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION
IF THESE PROCEDURES ARE NOT FOLLOWED.
NOTE: THE ORIGINAL SIZE OF THIS DRAWING SHEET IS: 36"X48"
PROJECT NUMBER:
SUBMITTAL:
REVISION:
DATE DESCRIPTION
PERMIT NUMBER:
CLIENT:
4/11/2023 1:54:59 PM
A4.0
FLOOR PLANS
2022001
RI
Z
K
O
R
E
S
I
D
E
N
C
E
30
6
V
I
A
L
I
D
O
N
O
R
D
NE
W
P
O
R
T
B
E
A
C
H
,
C
A
9
2
6
6
3
DE
S
I
G
N
D
E
V
E
L
O
P
M
E
N
T
CAMILLE AND JOUMANA RIZKO
PRINCIPAL: HOMER OATMAN
DRAWN BY: AS
1/4" = 1'-0"1FIRST FLOOR PLAN
1/4" = 1'-0"2SECOND FLOOR PLAN
NO. DATE DESCRIPTION
1/4" = 1'-0"3BASEMENT PLAN
NORTH (REF)
C O M P A S S
N O R T H
FLOOR AREA CALCULATIONS
NEW TOTAL SQUARE FOOTAGE:
FIRST FLOOR (INCLUDING GARAGE): 2,679 SF
SECOND FLOOR: 2,381 SF
TOTAL:5,060 SF
COVERED TERRACE: 369 SF
FRONT 2ND FL. BALCONY: 124 SF
REAR 2ND FL. BALCONY: 221 SF
LOT SIZE:4,050 SF
LOT DIMENSIONS: 90' X 45'
BUILABLE AREA:
LOT SIZE (4,050 SF) MINUS
SETBACKS (868 SF): 3,182 SF
ALLOWABLE FLOOR AREA:
1.75 X BUILDABLE AREA: 5,568 SF
OPEN VOLUME:
15% OF BUILDABLE AREA REQUIRED:477 SF
PROVIDED: 689 SF
CIRCULATION FLOOR AREA COUNTED
ON 1ST FL. ONLY
(238 SF - COUNTED IN 1ST FL. TOTAL)
AREA: 2381 SF
OP
E
N
V
O
L
U
M
E
:
2
2
1
S
F
1'-7"16'-10"14'-11 1/8"43'-5 7/8"6'-0"
15'-7 7/8"
15'-8 1/8"
5'-5 1/4"
7'-3 7/8"
3'-0"
4'-8 3/4"
8'-2 7/8"3'-9 1/4"2'-11"
7'-2 3/4"
6'-6 1/4"
36'-9 1/4"
31'-4"
CIRCULATION FLOOR AREA COUNTED
ON 1ST FL. ONLY
(238 SF - COUNTED IN 1ST FL. TOTAL)
AREA: 2679 SF
23'-3 1/2"46'-6 1/8"6'-2 3/4"
31'-7"
4'-0 3/8"
14'-11 1/8"30'-5 3/4"9'-0 3/8"
1'-3 1/4"
1 3/8"
OPEN VOLUME: 99 SF
OP
E
N
V
O
L
U
M
E
:
3
6
9
S
F
9'-11 3/4"
37'-0"
5'-5"
NON-HABITABLE STORAGE
AREA
(NOT COUNTED TOWARDS
FLOOR AREA)
10'-6 1/4"
37'-0"
LICENCE STAMP:
THESE DRAWINGS ARE THE PROPERTY OF OATMAN
ARCHITECTS AND SHALL NOT BE MODIFIED OR USED ON ANY
OTHER PROJECT OR SITE WITHOUT WRITTEN PERMISSION.
IT IS THE OWNER'S AND IT'S GENERAL CONTRACTOR'S
RESPONSIBILITY, PRIOR TO OR DURING CONSTRUCTION, TO
NOTIFY THE ARCHITECT IN WRITING OF ANY PERCEIVED
ERRORS OR OMISSIONS IN THE PLANS AND/ OR GENERAL
NOTES OF WHICH A CONTRACTOR THOROUGHLY
KNOWLEDGEABLE WITH THE BUILDING CODES AND MEANS &
METHODS OF CONSTRUCTION SHOULD REASONABLY BE
AWARE. WRITTEN INSTRUCTIONS ADDRESSING SUCH
PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED
FROM THE ARCHITECT PRIOR TO THE OWNER OR OWNER'S
CONTRACTOR PROCEEDING WITH THE WORK. THE OWNER
WILL BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION
IF THESE PROCEDURES ARE NOT FOLLOWED.
NOTE: THE ORIGINAL SIZE OF THIS DRAWING SHEET IS: 36"X48"
PROJECT NUMBER:
SUBMITTAL:
REVISION:
DATE DESCRIPTION
PERMIT NUMBER:
CLIENT:
4/11/2023 1:55:05 PM
A4.1
FLOOR AREA
EXHIBIT
2022001
RI
Z
K
O
R
E
S
I
D
E
N
C
E
30
6
V
I
A
L
I
D
O
N
O
R
D
NE
W
P
O
R
T
B
E
A
C
H
,
C
A
9
2
6
6
3
DE
S
I
G
N
D
E
V
E
L
O
P
M
E
N
T
CAMILLE AND JOUMANA RIZKO
PRINCIPAL: HOMER
OATMAN
DRAWN BY: Author
NO. DATE DESCRIPTION
1/4" = 1'-0"2SECOND FLOOR AREA CALCS
1/4" = 1'-0"1FIRST FLOOR AREA CALCS
1/4" = 1'-0"3BASEMENT AREA CALCS NORTH (REF)
C O M P A S S
N O R T H
DN
ROOF PLAN NOTES
1. DO NOT SCALE DRAWINGS.
2. REFER TO GENERAL NOTES FOR ADDITIONAL REQUIRED INFORMATION.
3. ALL RIDGE ELEVATIONS ARE TO TOP OF FINISH MATERIAL.
4. ALL FLASHING, SHEET METAL, VENT STACKS AND PIPES SHALL BE
COPPER OR PAINTED TO MATCH ADJACENT BUILDING SURFACE.
5. PROVIDE COPPER FLASHING AT ALL VALLEYS AND ROOF TO WALL
CONDITIONS. REFER TO DETAILS.
6. ALL PLUMBING AND EQUIPMENT VENTS MUST BE CONSOLIDATED AND
LOCATED IN AREAS THAT MINIMIZE THEIR VISIBILITY. VENTS MUST BE AS
LOW IN HEIGHT AS ALLOWED BY CODE AND SATISFY THE REQUIREMENTS
OF THE DESIGN GUIDELINES.
7. IN "CALIFORNIA" DOUBLE FRAMING AREAS PROVIDE OPENINGS INTO MAIN
ATTIC SPACE FOR ADEQUATE VENTILATION, PER C.R.C SECTION R806.
8. IF "CALIFORNIA" DOUBLE FRAME AREA EXCEEDS 30 SQUARE FEET AND
HAS A 30" MIN. CLEAR HEADROOM, PROVIDE A 22"X30" MIN. ACCESS
THROUGH MAIN ROOF SHEATHING, PER C.R.C SECTION R807. VERIFY
OPENINGS IN ROOF SHEATHING WITH STRUCTURAL ENGINEER.
9. ALL BOX COLUMNS AND 'POP-OUTS' SHALL REMAIN OPEN AT TOP PLATE
LINE TO ALLOW FOR VENTILATION.
10. AT ALL AREAS WITHIN THE ROOF ATTIC THAT EXCEED 30 SQUARE FEET
AND WITH 30" MIN. CLEAR HEADROOM, PROVIDE A 22"X30" MIN. ATTIC
ACCESS TO THOSE AREAS, PER C.R.C SECTION R807. ATTICS WITH
APPLIANCES OR F.A.U UNITS INSTALLED IN THEM, PROVIDE A 30"x30" MIN.
ATTIC ACCESS, (PROVIDED F.A.U. MAY PASS THROUGH) WITH 30" MIN.
CLEAR HEADROOM. PROVIDE WEATHER STRIPS AT PANEL TO PREVENT
BACK DRAFT.
11. THE CONTRACTOR SHALL INSTALL DRAFT STOPPING TO SUBDIVIDE
ATTIC SPACES AND CONCEALED ROOF SPACES, SUCH THAT ANY
HORIZONTAL AREA DOES NOT EXCEED 1,000 S.F., OR PER MIN.
REQUIREMENTS OF C.R.C SECTION 302.12.DRAFTSTOP MATERIALS TO BE
NO LESS THAN1/2" GYP. BD. OR 3/8" PLYWOOD INSTALLED PARALLEL
TO FLOOR AND ROOF FRAMING.
12. PRIOR TO THE RELEASE OF THE ROOF SHEATHING INSPECTION, THE
APPLICANT SHALL SUBMIT CERTIFICATION, BY A SURVEY OR OTHER
APPROPRIATE METHOD, THAT THE HEIGHT OF THE STRUCTURES IS IN
COMPLIANCE WITH THE ADOPTED APPROVAL RESOLUTION, AND THE
HEIGHT LIMITATIONS OF THE APPLICABLE ZONING DISTRICT.
13. PRIOR TO THE ISSUANCE OF A CERTIFICATE OF USE AND OCCUPANCY,
WRITTEN CERTIFICATION BY A CALIFORNIA REGISTERED ENGINEER THAT
THE ROOF SLOPE IS IN CONFORMANCE WITH THE APPROVED PLANS
SHALL BE SUBMITTED TO THE CITY BUILDING INSPECTOR.
14. CLASS "A" ROOFING ASSEMBLY REQUIRED PER I.CC. ESR-1489.
15. ALL ROOF EAVE GUTTERS SHALL BE 6" CONTINUOUS, HALF-ROUND,
NON-EXTRUDED, GALVANIZED METAL WITH GUTTER GUARDS PER C.R.C
R337.5.4. ALL DOWNSPOUTS SHALL BE 4" DIA. ROUND, GALVANIZED
METAL w/ GENTLE SWEEPING CURVES. REFER TO EXTERIOR ELEVATIONS
FOR LOCATION(S) AND COLOR.
16. COORDINATE CONNECTION OF CONTINUOUS ROOF EAVE GUTTERS AND
DOWNSPOUTS TO ALLOW WATER TO FLOW AWAY FROM THE HOUSE.
DOWNSPOUTS SHOULD BE CONNECTED TO CLOSED PIPES THAT
DISCHARGE INTO SITE STORM DRAIN SYSTEM OR ON TO PAVED
SURFACES THAT CARRY THE WATER AWAY AT LEAST 5'-0" FROM THE
BUILDINGS FOUNDATION. REFER TO CIVIL DRAWINGS FOR SITE
DRAINAGE.
17. VENTING SHALL EXTEND ABOVE THE ROOF AND SHALL TERMINATE IN A
VENT CAP. TERMINATION POINTS SHALL BE AT LEAST 4 FEET BELOW OR
HORIZONTALLY FROM AND 1 FOOT ABOVE ANY OPENING INTO THE
BUILDING, BE AT LEAST 3 FEET ABOVE ANY FORCED AIR INLET INTO THE
BUILDING LOCATED WITHIN 10 FEET, AND SHALL BE 4 FEET AWAY FROM
THE PROPERTY LINE, PER C.M.C. SECTIONS 802.6.2 AND 802.6.2.6.
18. ANY FORCED AIR UNITS LOCATED IN THE ATTIC MUST BE POSITIONED IN
SUCH A MANNER THAT THE REQUIRED DISTANCE FROM THE VENT OUTLET
TO THE TOP OF THE FLUE CAP IS WITHIN THE ATTIC, ALLOWING THE
EXTERIOR HEIGHT OF THE FLUE CAP ABOVE THE FINISHED ROOFING TO
BE THE MINIMUM ALLOWED BY CODE.
19. SOLAR REFLECTANCE AND THERMAL EMMITTANCE FOR NEW
CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE COOL ROOF
STANDARDS AND THE CALIF. ENERGY CODE, SECTION 150.0
20. EXPOSED ATTIC FLOOR INSULATION SHALL HAVE A CRITICAL RADIANT
FLUX OF NOT LESS THAN 0.12 WATT PER SQUARE CENTIMETER PER ASTM
E 970.
2
A6.1
2
A6.0
1
A6.0
1
A6.1
3" / 1'-0"
3" / 1'-0"
3" / 1'-0"
3" / 1'-0"
OUTLINE OF 2ND FLOOROUTLINE OF 1ST FLOOR
RAKE
4'-9"
EAVE (TYP.)
1'-0"
RAKE (TYP.)
1'-0"
RAKE
3'-2"
RAKE
8'-6"ENTRY ROOF
ROOF 1
SLATE TILE
ROOFING (TYP.)
ROOF 2
SLATE TILE
ROOFING (TYP.)
ROOF 5
SLATE TILE
ROOFING (TYP.)
ROOF 4
SLATE TILE
ROOFING (TYP.)
ROOF 6
SLATE TILE
ROOFING (TYP.)
SLATE TILE
ROOFING (TYP.)
SOLAR PANEL
DESIGN - BY
OTHERS
ROOF OVER CHIMNEY (BELOW)
EAVE TO PL
2'-6"
RAKE TO PL
4'-0"
EAVE TO PL
3'-1 3/8"
EAVE TO PL
3'-1 3/8"
CRICKETCRICKET
1 1/4" / 1'-0"
SLATE TILE ROOFING APPLIED
OVER LOW SLOPE ROOFING
MEMBRANE
LOW SLOPE
ROOF 3
3" / 1'-0"3" / 1'-0"3" / 1'-0"3" / 1'-0"3" / 1'-0"
LICENCE STAMP:
THESE DRAWINGS ARE THE PROPERTY OF OATMAN
ARCHITECTS AND SHALL NOT BE MODIFIED OR USED ON ANY
OTHER PROJECT OR SITE WITHOUT WRITTEN PERMISSION.
IT IS THE OWNER'S AND IT'S GENERAL CONTRACTOR'S
RESPONSIBILITY, PRIOR TO OR DURING CONSTRUCTION, TO
NOTIFY THE ARCHITECT IN WRITING OF ANY PERCEIVED
ERRORS OR OMISSIONS IN THE PLANS AND/ OR GENERAL
NOTES OF WHICH A CONTRACTOR THOROUGHLY
KNOWLEDGEABLE WITH THE BUILDING CODES AND MEANS &
METHODS OF CONSTRUCTION SHOULD REASONABLY BE
AWARE. WRITTEN INSTRUCTIONS ADDRESSING SUCH
PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED
FROM THE ARCHITECT PRIOR TO THE OWNER OR OWNER'S
CONTRACTOR PROCEEDING WITH THE WORK. THE OWNER
WILL BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION
IF THESE PROCEDURES ARE NOT FOLLOWED.
NOTE: THE ORIGINAL SIZE OF THIS DRAWING SHEET IS: 36"X48"
PROJECT NUMBER:
SUBMITTAL:
REVISION:
DATE DESCRIPTION
PERMIT NUMBER:
CLIENT:
4/11/2023 1:55:05 PM
A5.0
ROOF PLAN
2022001
RI
Z
K
O
R
E
S
I
D
E
N
C
E
30
6
V
I
A
L
I
D
O
N
O
R
D
NE
W
P
O
R
T
B
E
A
C
H
,
C
A
9
2
6
6
3
DE
S
I
G
N
D
E
V
E
L
O
P
M
E
N
T
CAMILLE AND JOUMANA RIZKO
PRINCIPAL: HOMER
OATMAN
DRAWN BY: ALLIE
SCHIEBLE
NO. DATE DESCRIPTION
A 4/11/23 OWNER REQUESTED
CHANGE
1/4" = 1'-0"1ROOF
LIDO ISLE COMMUNITY ASSOC.
FLAT ROOF AREA CALCS
TOTAL ROOF AREA: 2724.34 SF
25% OF TOTAL ROOF AREA: 681.09 SF
FLAT ROOF AREA (<3:12 PITCH): 677 SF
TOTAL ROOF AREA (INCLUDING EAVES): 3146 SF
10% OF TOTAL ROOF AREA: 314.6 SF
STANDING SEAM METAL ROOF AREA: 175 SF
A
ELEVATION NOTES
1. DO NOT SCALE DRAWINGS.
2. REFER TO GENERAL NOTES FOR ADDITIONAL REQUIRED
INFORMATION.
3. ALL RIDGE ELEVATIONS ARE TO TOP OF FINISH MATERIAL.
4. CONTRACTOR TO PROVIDE MOCK-UP OF ROOF TILES,
EXTERIOR PLASTER FINISH COLOR AND TEXTURE, HEAVY TIMBER
WOOD STAIN COLOR, GUTTER AND DOWN SPOUT PAINT COLOR,
AND EXTERIOR WINDOW AND DOOR FRAME FINISH FOR
ARCHITECT'S APPROVAL PRIOR TO CONSTRUCTION.
5. BUILDING ADDRESS SHALL BE PROVIDED ON THE BUILDING IN
SUCH A POSITION AS TO BE PLAINLY VISIBLE AND LEGIBLE
FROM THE STREET AND TO BE A MINIMUM OF 4" HIGH X 1" WIDE
NONCOMBUSTIBLE, CONTRASTING MATERIALS OR PER LOCAL
CITY AND FIRE DEPARTMENT REQUIREMENTS.
6. REFER TO LANDSCAPE DRAWINGS FOR THE HARDSCAPE
PAVING MATERIAL PLAN, SOFTSCAPE PLANTING PLAN,
IRRIGATION PLAN, GARDEN WALLS, EXTERIOR GUARDRAILS AND
HANDRAILS, FENCE(S), GATES, SWIMMING POOL AND SPA
PLAN. . .ETC.
EXTERIOR ELEVATION AND SECTION KEYNOTES ELEVATION LEGEND
PROPERTY LINE
SETBACK LINE
NATURAL GRADE/HEIGHT
LIMITA
A101
1
SIM
KEYNOTE
DETAIL CALLOUT
ROOF VENT
T.O. SLAB
13.42'
T.O. PLT. 2ND FL. (FRONT)
32.08'
LICA HT. LIMIT
36.83'
FIN. FL. 1
13.61'
HDR. HT. 1
21.42'
T.O. SHTG 2ND FL. (FRONT)
23.71'
FIN. FL. 2 (FRONT)
23.90'
T.O. GARAGE PLT.
22.62'
HDR. HT. 2 (FRONT)
31.71'
AVG TOC
12.83'
MIN.
3'-6"
PR
O
P
E
R
T
Y
LI
N
E
PR
O
P
E
R
T
Y
LI
N
E
T.O. GAR. SLAB
12.90'
9'-0"
T.O. SLAB
13.42'
T.O. SLAB
13.42'
T.O. SHTG 2ND FL.
24.71'
T.O. PLT. 2ND FL. (FRONT)
32.08'
1ST FL. CLG. HT.
23.40'
LICA HT. LIMIT
36.83'
LICA HT. LIMIT
36.83'
FIN. FL. 1
13.61'
FIN. FL. 1
13.61'
FIN. FL. 2
24.90'
HDR. HT. 2
32.71'
HDR. HT. 1
21.42'
T.O. SHTG 2ND FL. (FRONT)
23.71'
FIN. FL. 2 (FRONT)
23.90'
T.O. GARAGE PLT.
22.62'
HDR. HT. 2 (FRONT)
31.71'
2ND FL. CLG. HT.
33.90'
AVG TOC
12.83'
AVG TOC
12.83'
FIN. SURFACE AT BAYFRONT
9.02'
FIN. GR. AT BAYFRONT
8.90'
FRAMING
9'-2 7/8"
FRAMING
10'-0 3/8"
T.O. PLT. 1ST FL.
23.45'
T.O. PLT. 2ND FL.
33.95'
PR
O
P
E
R
T
Y
LI
N
E
PR
O
P
E
R
T
Y
LI
N
E
T.O. GAR. SLAB
12.90'
T.O. GAR. SLAB
12.90'
CLR
9'-0"
1'-0"
CLR
9'-9 1/2"
LICENCE STAMP:
THESE DRAWINGS ARE THE PROPERTY OF OATMAN
ARCHITECTS AND SHALL NOT BE MODIFIED OR USED ON ANY
OTHER PROJECT OR SITE WITHOUT WRITTEN PERMISSION.
IT IS THE OWNER'S AND IT'S GENERAL CONTRACTOR'S
RESPONSIBILITY, PRIOR TO OR DURING CONSTRUCTION, TO
NOTIFY THE ARCHITECT IN WRITING OF ANY PERCEIVED
ERRORS OR OMISSIONS IN THE PLANS AND/ OR GENERAL
NOTES OF WHICH A CONTRACTOR THOROUGHLY
KNOWLEDGEABLE WITH THE BUILDING CODES AND MEANS &
METHODS OF CONSTRUCTION SHOULD REASONABLY BE
AWARE. WRITTEN INSTRUCTIONS ADDRESSING SUCH
PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED
FROM THE ARCHITECT PRIOR TO THE OWNER OR OWNER'S
CONTRACTOR PROCEEDING WITH THE WORK. THE OWNER
WILL BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION
IF THESE PROCEDURES ARE NOT FOLLOWED.
NOTE: THE ORIGINAL SIZE OF THIS DRAWING SHEET IS: 36"X48"
PROJECT NUMBER:
SUBMITTAL:
REVISION:
DATE DESCRIPTION
PERMIT NUMBER:
CLIENT:
4/11/2023 1:55:17 PM
A6.0
EXTERIOR
ELEVATIONS
2022001
RI
Z
K
O
R
E
S
I
D
E
N
C
E
30
6
V
I
A
L
I
D
O
N
O
R
D
NE
W
P
O
R
T
B
E
A
C
H
,
C
A
9
2
6
6
3
DE
S
I
G
N
D
E
V
E
L
O
P
M
E
N
T
CAMILLE AND JOUMANA RIZKO
PRINCIPAL: HOMER
OATMAN
DRAWN BY: ALLIE
SCHIEBLE
#CATEGORY MANUFACTURER MATERIAL COLOR FINISH NOTES
A EXTERIOR PLASTER MERLEX 3-COAT STUCCO SYSTEM GP-8685 SMOOTH COAT EXTERIOR LATH & PLASTER SHALL CONFORM TO C.R.C. SECTION 703.6 - 703.6.5 & R327. PROVIDE
FIBERGLASS ANTI-CRACHING MESH WITH DRYBOND CEMENTITIOUS BONDER COAT & POLYBOND
CEMENT ACRYLIC TOP COAT.
NO. DATE DESCRIPTION
A 4/11/23 OWNER REQUESTED
CHANGE
1/4" = 1'-0"1FRONT ELEVATION
1/4" = 1'-0"2LEFT ELEVATION
A
A
ELEVATION NOTES
1. DO NOT SCALE DRAWINGS.
2. REFER TO GENERAL NOTES FOR ADDITIONAL REQUIRED
INFORMATION.
3. ALL RIDGE ELEVATIONS ARE TO TOP OF FINISH MATERIAL.
4. CONTRACTOR TO PROVIDE MOCK-UP OF ROOF TILES,
EXTERIOR PLASTER FINISH COLOR AND TEXTURE, HEAVY TIMBER
WOOD STAIN COLOR, GUTTER AND DOWN SPOUT PAINT COLOR,
AND EXTERIOR WINDOW AND DOOR FRAME FINISH FOR
ARCHITECT'S APPROVAL PRIOR TO CONSTRUCTION.
5. BUILDING ADDRESS SHALL BE PROVIDED ON THE BUILDING IN
SUCH A POSITION AS TO BE PLAINLY VISIBLE AND LEGIBLE
FROM THE STREET AND TO BE A MINIMUM OF 4" HIGH X 1" WIDE
NONCOMBUSTIBLE, CONTRASTING MATERIALS OR PER LOCAL
CITY AND FIRE DEPARTMENT REQUIREMENTS.
6. REFER TO LANDSCAPE DRAWINGS FOR THE HARDSCAPE
PAVING MATERIAL PLAN, SOFTSCAPE PLANTING PLAN,
IRRIGATION PLAN, GARDEN WALLS, EXTERIOR GUARDRAILS AND
HANDRAILS, FENCE(S), GATES, SWIMMING POOL AND SPA
PLAN. . .ETC.
EXTERIOR ELEVATION AND SECTION KEYNOTES ELEVATION LEGEND
PROPERTY LINE
SETBACK LINE
NATURAL GRADE/HEIGHT
LIMITA
A101
1
SIM
KEYNOTE
DETAIL CALLOUT
ROOF VENT
T.O. SLAB
13.42'
T.O. SHTG 2ND FL.
24.71'
1ST FL. CLG. HT.
23.40'
LICA HT. LIMIT
36.83'
FIN. FL. 1
13.61'
FIN. FL. 2
24.90'
HDR. HT. 2
32.71'
2ND FL. CLG. HT.
33.90'
HDR. HT. (REAR)
22.42'
MIN.
3'-6"
AVG TOC
12.83'
FIN. SURFACE AT BAYFRONT
9.02'
FIN. GR. AT BAYFRONT
8.90'
T.O. PLT. 1ST FL.
23.45'
T.O. PLT. 2ND FL.
33.95'
PR
O
P
E
R
T
Y
LI
N
E
PR
O
P
E
R
T
Y
LI
N
E
T.O. SLAB
13.42'T.O. SLAB
13.42'
T.O. SHTG 2ND FL.
24.71'
T.O. PLT. 2ND FL. (FRONT)
32.08'
1ST FL. CLG. HT.
23.40'
LICA HT. LIMIT
36.83'
LICA HT. LIMIT
36.83'
FIN. FL. 1
13.61'FIN. FL. 1
13.61'
FIN. FL. 2
24.90'
HDR. HT. 2
32.71'
HDR. HT. 1
21.42'HDR. HT. 1
21.42'
T.O. SHTG 2ND FL. (FRONT)
23.71'
FIN. FL. 2 (FRONT)
23.90'
T.O. GARAGE PLT.
22.62'
HDR. HT. 2 (FRONT)
31.71'
2ND FL. CLG. HT.
33.90'
MIN.
3'-6"
MIN.
3'-6"
AVG TOC
12.83'
AVG TOC
12.83'
FIN. SURFACE AT BAYFRONT
9.02'
FIN. GR. AT BAYFRONT
8.90'
T.O. PLT. 1ST FL.
23.45'
T.O. PLT. 2ND FL.
33.95'
PR
O
P
E
R
T
Y
LI
N
E
PR
O
P
E
R
T
Y
LI
N
E
T.O. GAR. SLAB
12.90'
LICENCE STAMP:
THESE DRAWINGS ARE THE PROPERTY OF OATMAN
ARCHITECTS AND SHALL NOT BE MODIFIED OR USED ON ANY
OTHER PROJECT OR SITE WITHOUT WRITTEN PERMISSION.
IT IS THE OWNER'S AND IT'S GENERAL CONTRACTOR'S
RESPONSIBILITY, PRIOR TO OR DURING CONSTRUCTION, TO
NOTIFY THE ARCHITECT IN WRITING OF ANY PERCEIVED
ERRORS OR OMISSIONS IN THE PLANS AND/ OR GENERAL
NOTES OF WHICH A CONTRACTOR THOROUGHLY
KNOWLEDGEABLE WITH THE BUILDING CODES AND MEANS &
METHODS OF CONSTRUCTION SHOULD REASONABLY BE
AWARE. WRITTEN INSTRUCTIONS ADDRESSING SUCH
PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED
FROM THE ARCHITECT PRIOR TO THE OWNER OR OWNER'S
CONTRACTOR PROCEEDING WITH THE WORK. THE OWNER
WILL BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION
IF THESE PROCEDURES ARE NOT FOLLOWED.
NOTE: THE ORIGINAL SIZE OF THIS DRAWING SHEET IS: 36"X48"
PROJECT NUMBER:
SUBMITTAL:
REVISION:
DATE DESCRIPTION
PERMIT NUMBER:
CLIENT:
4/11/2023 1:55:29 PM
A6.1
EXTERIOR
ELEVATIONS
2022001
RI
Z
K
O
R
E
S
I
D
E
N
C
E
30
6
V
I
A
L
I
D
O
N
O
R
D
NE
W
P
O
R
T
B
E
A
C
H
,
C
A
9
2
6
6
3
DE
S
I
G
N
D
E
V
E
L
O
P
M
E
N
T
CAMILLE AND JOUMANA RIZKO
PRINCIPAL: HOMER
OATMAN
DRAWN BY: ALLIE
SCHIEBLE
#CATEGORY MANUFACTURER MATERIAL COLOR FINISH NOTES
A EXTERIOR PLASTER MERLEX 3-COAT STUCCO SYSTEM GP-8685 SMOOTH COAT EXTERIOR LATH & PLASTER SHALL CONFORM TO C.R.C. SECTION 703.6 - 703.6.5 & R327. PROVIDE
FIBERGLASS ANTI-CRACHING MESH WITH DRYBOND CEMENTITIOUS BONDER COAT & POLYBOND
CEMENT ACRYLIC TOP COAT.
NO. DATE DESCRIPTION
A 4/11/23 OWNER REQUESTED
CHANGE
1/4" = 1'-0"1REAR ELEVATION
1/4" = 1'-0"2RIGHT ELEVATION
A
A
SECTION LEGEND
NEW 2x6 WOOD STUD
WALLS
NEW CONC. WALL/SLAB,
REFER TO STRUCTURAL
NEW 2x4 WOOD STUD
WALLS/CEILINGS
1HR FIRE RATED
PROPERTY LINE
SETBACK LINE
NATURAL GRADE/HEIGHT
LIMIT
NEW WOOD JOIST
FLOOR/ROOF
A
A101
1 SIM
KEYNOTE
DETAIL CALLOUT
SECTION NOTES
1. DO NOT SCALE DRAWINGS.
2. REFER TO GENERAL NOTES FOR ADDITIONAL REQUIRED
INFORMATION.
3. TITLE-24 BUILDING ENERGY EFFICIENCY STANDARDS:
A. INSULATION:
• ROOF/ CEILINGS (R-38)
• EXTERIOR WALLS, INCL. FURRED BASEMENT WALLS (R-19)
• FRAMED FLOORS (R-30)
• BATHROOM AND LAUNDRY ROOM INTERIOR WALLS (R-13)
B. **USE ABOVE NOTED VALUES IF GREATER THAN TITLE-24
MINIMUMS.
C. AFTER INSTALLING WALL, CEILING, OR FLOOR INSULATION, THE
INSTALLER SHALL MAKE AVAILABLE TO THE ENFORCEMENT
AGENCY OR POST IN A CONSPICUOUS LOCATION IN THE
BUILDING A CERTIFICATE SIGNED BY THE INSTALLER STATING
THAT THE INSTALLATION IS CONSISTENT WITH THE PLANS AND
SPECIFICATIONS DESCRIBED IN SECTION 10-103(A)2.A AND
FOR WHICH THE BUILDING PERMIT WAS ISSUED AND
CONFORMS WITH THE REQUIREMENTS OF PART 6. THE
CERTIFICATE SHALL STATE THE MANUFACTURERS NAME AND
MATERIAL IDENTIFICATION, THE INSTALLED "R" VALUE AND (IN
APPLICATION OF LOOSE FILL INSULATION) THE MINIMUM
INSTALLED WEIGHT PER SQUARE FOOT CONSISTENT WITH THE
MANUFACTURERS LABELED INSTALLED DESIGN DENSITY FOR
THE DESIRED "R" VALUE.
4. FIREBLOCKING AND DRAFTSTOPPING SHALL BE PROVIDE
THROUGH OUT THE STRUCTURE PER C.R.C. SECTIONS R302.11
AND R302.12.
5. EXPOSED ATTIC FLOOR INSULATION SHALL HAVE A CRITICAL
RADIANT FLUX OF NOT LESS THAN 0.02 WATT PER SQUARE
CENTIMETER PER ASTM E 970.
6. PROVIDE A MINIMUM 1" AIRSPACE REQUIRED BETWEEN
INSULATION AND ROOF SHEATHING PER C.R.C SECTION R806.3.
7. REFER TO SHEET (T-24.0) FOR THE TITLE-24 ENERGY
CALCULATION FORMS AND MANDATORY REQUIREMENTS (CF-1R
AND MF-1R) FOR ENERGY COMPLIANCE.
8. BUILDING SECTIONS ARE FOR ARCHITECTURAL DESIGN INTENT
ONLY.
• REFER TO STRUCTURAL DRAWINGS FOR:
A. FOUNDATION AND FOOTING DETAILS.
B. FLOOR, WALL, AND ROOF WOOD FRAMING MEMBER SIZES
AND DETAILS.
C. STRUCTURAL STEEL MEMBER SIZES AND DETAILS.
D. DIRECTION OF WOOD FRAMING AND STEEL MEMBERS.
E. SHEAR WALL AND HOLD-DOWN LOCATION, SIZES AND
DETAILS.
9. REFER TO INTERIOR DESIGN DRAWINGS FOR ALL INTERIOR
FINISHES, CEILINGS HEIGHTS AND DESIGNS / DETAILS.
EXTERIOR ELEVATION AND SECTION KEYNOTES
T.O. SLAB
13.42'
T.O. SHTG 2ND FL.
24.71'
T.O. PLT. 2ND FL. (FRONT)
32.08'
1ST FL. CLG. HT.
23.40'
LICA HT. LIMIT
36.83'
LICA HT. LIMIT
36.83'
FIN. FL. 1
13.61'
FIN. FL. 2
24.90'
HDR. HT. 2
32.71'
T.O. SHTG 2ND FL. (FRONT)
23.71'
FIN. FL. 2 (FRONT)
23.90'
T.O. GARAGE PLT.
22.62'
HDR. HT. 2 (FRONT)
31.71'
2ND FL. CLG. HT.
33.90'
HDR. HT. (REAR)
22.42'
AVG TOC
12.83'
AVG TOC
12.83'
FIN. SURFACE AT BAYFRONT
9.02'
FIN. GR. AT BAYFRONT
8.90'
PRIMARY WIC
P.SHOWERBEDROOM 3
CL.3
CL.4BEDROOM 4
3-CAR
GARAGE BA.2
GUEST
BEDROOM 2
BACK
KITCHEN/PANTRY KITCHEN DINING ROOM
T.O. PLT. 1ST FL.
23.45'
T.O. PLT. 2ND FL.
33.95'
FRAMING
10'-0 3/8"
9'-0"
FRAMING
9'-2 7/8"
8'-0"
8'-0"
FRAMING
9'-8 5/8"
MIN.
3'-6"
MIN.
3'-6"
24'-0"
PR
O
P
E
R
T
Y
LI
N
E
PR
O
P
E
R
T
Y
LI
N
E
T.O. GAR. SLAB
12.90'
CLEAR
9'-0"
GARAGE DR HT
8'-0"
FRAMING
8'-4 1/2"
CLEAR
9'-9 1/2"
T.O. SLAB
13.42'
T.O. SHTG 2ND FL.
24.71'
T.O. PLT. 2ND FL. (FRONT)
32.08'
1ST FL. CLG. HT.
23.40'
LICA HT. LIMIT
36.83'
LICA HT. LIMIT
36.83'
FIN. FL. 1
13.61'
FIN. FL. 2
24.90'
HDR. HT. 2
32.71'
HDR. HT. 1
21.42'
HDR. HT. 1
21.42'
T.O. SHTG 2ND FL. (FRONT)
23.71'
FIN. FL. 2 (FRONT)
23.90'
T.O. GARAGE PLT.
22.62'
HDR. HT. 2 (FRONT)
31.71'
2ND FL. CLG. HT.
33.90'
HDR. HT. (REAR)
22.42'
AVG TOC
12.83'
FIN. SURFACE AT BAYFRONT
9.02'
FIN. GR. AT BAYFRONT
8.90'
T.O. PLT. 1ST FL.
23.45'
T.O. PLT. 2ND FL.
33.95'
PRIMARY
BEDROOM LAUNDRY OFFICE/DEN
GREAT ROOM
PR
O
P
E
R
T
Y
LI
N
E
PR
O
P
E
R
T
Y
LI
N
E
MIN.
3'-6"
15'-0"
FRAMING
9'-2 7/8"
CLR
9'-0"
FRAMING
10'-0 3/8"
CLR
9'-9 1/2"
LICENCE STAMP:
THESE DRAWINGS ARE THE PROPERTY OF OATMAN
ARCHITECTS AND SHALL NOT BE MODIFIED OR USED ON ANY
OTHER PROJECT OR SITE WITHOUT WRITTEN PERMISSION.
IT IS THE OWNER'S AND IT'S GENERAL CONTRACTOR'S
RESPONSIBILITY, PRIOR TO OR DURING CONSTRUCTION, TO
NOTIFY THE ARCHITECT IN WRITING OF ANY PERCEIVED
ERRORS OR OMISSIONS IN THE PLANS AND/ OR GENERAL
NOTES OF WHICH A CONTRACTOR THOROUGHLY
KNOWLEDGEABLE WITH THE BUILDING CODES AND MEANS &
METHODS OF CONSTRUCTION SHOULD REASONABLY BE
AWARE. WRITTEN INSTRUCTIONS ADDRESSING SUCH
PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED
FROM THE ARCHITECT PRIOR TO THE OWNER OR OWNER'S
CONTRACTOR PROCEEDING WITH THE WORK. THE OWNER
WILL BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION
IF THESE PROCEDURES ARE NOT FOLLOWED.
NOTE: THE ORIGINAL SIZE OF THIS DRAWING SHEET IS: 36"X48"
PROJECT NUMBER:
SUBMITTAL:
REVISION:
DATE DESCRIPTION
PERMIT NUMBER:
CLIENT:
4/11/2023 1:55:31 PM
A7.0
BUILDING
SECTIONS
2022001
RI
Z
K
O
R
E
S
I
D
E
N
C
E
30
6
V
I
A
L
I
D
O
N
O
R
D
NE
W
P
O
R
T
B
E
A
C
H
,
C
A
9
2
6
6
3
DE
S
I
G
N
D
E
V
E
L
O
P
M
E
N
T
CAMILLE AND JOUMANA RIZKO
PRINCIPAL: HOMER
OATMAN
DRAWN BY: Author
#CATEGORY MANUFACTURER MATERIAL COLOR FINISH NOTES
A EXTERIOR PLASTER MERLEX 3-COAT STUCCO SYSTEM GP-8685 SMOOTH COAT EXTERIOR LATH & PLASTER SHALL CONFORM TO C.R.C. SECTION 703.6 - 703.6.5 & R327. PROVIDE
FIBERGLASS ANTI-CRACHING MESH WITH DRYBOND CEMENTITIOUS BONDER COAT & POLYBOND
CEMENT ACRYLIC TOP COAT.
NO. DATE DESCRIPTION
A 4/11/23 OWNER REQUESTED
CHANGE
1/4" = 1'-0"2BUILDING SECTION 2A
1/4" = 1'-0"1BUILDING SECTION 1A
A
A
SECTION NOTES
1. DO NOT SCALE DRAWINGS.
2. REFER TO GENERAL NOTES FOR ADDITIONAL REQUIRED
INFORMATION.
3. TITLE-24 BUILDING ENERGY EFFICIENCY STANDARDS:
A. INSULATION:
• ROOF/ CEILINGS (R-38)
• EXTERIOR WALLS, INCL. FURRED BASEMENT WALLS (R-19)
• FRAMED FLOORS (R-30)
• BATHROOM AND LAUNDRY ROOM INTERIOR WALLS (R-13)
B. **USE ABOVE NOTED VALUES IF GREATER THAN TITLE-24
MINIMUMS.
C. AFTER INSTALLING WALL, CEILING, OR FLOOR INSULATION, THE
INSTALLER SHALL MAKE AVAILABLE TO THE ENFORCEMENT
AGENCY OR POST IN A CONSPICUOUS LOCATION IN THE
BUILDING A CERTIFICATE SIGNED BY THE INSTALLER STATING
THAT THE INSTALLATION IS CONSISTENT WITH THE PLANS AND
SPECIFICATIONS DESCRIBED IN SECTION 10-103(A)2.A AND
FOR WHICH THE BUILDING PERMIT WAS ISSUED AND
CONFORMS WITH THE REQUIREMENTS OF PART 6. THE
CERTIFICATE SHALL STATE THE MANUFACTURERS NAME AND
MATERIAL IDENTIFICATION, THE INSTALLED "R" VALUE AND (IN
APPLICATION OF LOOSE FILL INSULATION) THE MINIMUM
INSTALLED WEIGHT PER SQUARE FOOT CONSISTENT WITH THE
MANUFACTURERS LABELED INSTALLED DESIGN DENSITY FOR
THE DESIRED "R" VALUE.
4. FIREBLOCKING AND DRAFTSTOPPING SHALL BE PROVIDE
THROUGH OUT THE STRUCTURE PER C.R.C. SECTIONS R302.11
AND R302.12.
5. EXPOSED ATTIC FLOOR INSULATION SHALL HAVE A CRITICAL
RADIANT FLUX OF NOT LESS THAN 0.02 WATT PER SQUARE
CENTIMETER PER ASTM E 970.
6. PROVIDE A MINIMUM 1" AIRSPACE REQUIRED BETWEEN
INSULATION AND ROOF SHEATHING PER C.R.C SECTION R806.3.
7. REFER TO SHEET (T-24.0) FOR THE TITLE-24 ENERGY
CALCULATION FORMS AND MANDATORY REQUIREMENTS (CF-1R
AND MF-1R) FOR ENERGY COMPLIANCE.
8. BUILDING SECTIONS ARE FOR ARCHITECTURAL DESIGN INTENT
ONLY.
• REFER TO STRUCTURAL DRAWINGS FOR:
A. FOUNDATION AND FOOTING DETAILS.
B. FLOOR, WALL, AND ROOF WOOD FRAMING MEMBER SIZES
AND DETAILS.
C. STRUCTURAL STEEL MEMBER SIZES AND DETAILS.
D. DIRECTION OF WOOD FRAMING AND STEEL MEMBERS.
E. SHEAR WALL AND HOLD-DOWN LOCATION, SIZES AND
DETAILS.
9. REFER TO INTERIOR DESIGN DRAWINGS FOR ALL INTERIOR
FINISHES, CEILINGS HEIGHTS AND DESIGNS / DETAILS.
SECTION LEGEND
NEW 2x6 WOOD STUD
WALLS
NEW CONC. WALL/SLAB,
REFER TO STRUCTURAL
NEW 2x4 WOOD STUD
WALLS/CEILINGS
1HR FIRE RATED
PROPERTY LINE
SETBACK LINE
NATURAL GRADE/HEIGHT
LIMIT
NEW WOOD JOIST
FLOOR/ROOF
A
A101
1 SIM
KEYNOTE
DETAIL CALLOUT
EXTERIOR ELEVATION AND SECTION KEYNOTES
T.O. SLAB
13.42'
T.O. SLAB
13.42'
T.O. SHTG 2ND FL.
24.71'
1ST FL. CLG. HT.
23.40'
LICA HT. LIMIT
36.83'
LICA HT. LIMIT
36.83'
FIN. FL. 1
13.61'
FIN. FL. 1
13.61'
FIN. FL. 2
24.90'
HDR. HT. 2
32.71'
HDR. HT. 1
21.42'
2ND FL. CLG. HT.
33.90'
AVG TOC
12.83'
AVG TOC
12.83'
T.O. PLT. 1ST FL.
23.45'
T.O. PLT. 2ND FL.
33.95'
GUEST
BEDROOM 2
POWDER
BA.3
STAIR
PR
O
P
E
R
T
Y
LI
N
E
PR
O
P
E
R
T
Y
LI
N
E
T.O. SLAB
13.42'
T.O. SLAB
13.42'
T.O. SHTG 2ND FL.
24.71'
1ST FL. CLG. HT.
23.40'
LICA HT. LIMIT
36.83'
LICA HT. LIMIT
36.83'
FIN. FL. 1
13.61'
FIN. FL. 1
13.61'
FIN. FL. 2
24.90'
HDR. HT. 2
32.71'
HDR. HT. 1
21.42'
T.O. SHTG 2ND FL. (FRONT)
23.71'
FIN. FL. 2 (FRONT)
23.90'
T.O. GARAGE PLT.
22.62'
2ND FL. CLG. HT.
33.90'
AVG TOC
12.83'
AVG TOC
12.83'
T.O. PLT. 1ST FL.
23.45'
T.O. PLT. 2ND FL.
33.95'
STAIR
3-CAR
GARAGE
BA.4CL.4
PR
O
P
E
R
T
Y
LI
N
E
PR
O
P
E
R
T
Y
LI
N
E
T.O. GAR. SLAB
12.90'
T.O. GAR. SLAB
12.90'
LICENCE STAMP:
THESE DRAWINGS ARE THE PROPERTY OF OATMAN
ARCHITECTS AND SHALL NOT BE MODIFIED OR USED ON ANY
OTHER PROJECT OR SITE WITHOUT WRITTEN PERMISSION.
IT IS THE OWNER'S AND IT'S GENERAL CONTRACTOR'S
RESPONSIBILITY, PRIOR TO OR DURING CONSTRUCTION, TO
NOTIFY THE ARCHITECT IN WRITING OF ANY PERCEIVED
ERRORS OR OMISSIONS IN THE PLANS AND/ OR GENERAL
NOTES OF WHICH A CONTRACTOR THOROUGHLY
KNOWLEDGEABLE WITH THE BUILDING CODES AND MEANS &
METHODS OF CONSTRUCTION SHOULD REASONABLY BE
AWARE. WRITTEN INSTRUCTIONS ADDRESSING SUCH
PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED
FROM THE ARCHITECT PRIOR TO THE OWNER OR OWNER'S
CONTRACTOR PROCEEDING WITH THE WORK. THE OWNER
WILL BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION
IF THESE PROCEDURES ARE NOT FOLLOWED.
NOTE: THE ORIGINAL SIZE OF THIS DRAWING SHEET IS: 36"X48"
PROJECT NUMBER:
SUBMITTAL:
REVISION:
DATE DESCRIPTION
PERMIT NUMBER:
CLIENT:
4/11/2023 1:55:39 PM
A7.1
BUILDING
SECTIONS
2022001
RI
Z
K
O
R
E
S
I
D
E
N
C
E
30
6
V
I
A
L
I
D
O
N
O
R
D
NE
W
P
O
R
T
B
E
A
C
H
,
C
A
9
2
6
6
3
DE
S
I
G
N
D
E
V
E
L
O
P
M
E
N
T
CAMILLE AND JOUMANA RIZKO
PRINCIPAL: HOMER
OATMAN
DRAWN BY: Author
#CATEGORY MANUFACTURER MATERIAL COLOR FINISH NOTES
A EXTERIOR PLASTER MERLEX 3-COAT STUCCO SYSTEM GP-8685 SMOOTH COAT EXTERIOR LATH & PLASTER SHALL CONFORM TO C.R.C. SECTION 703.6 - 703.6.5 & R327. PROVIDE
FIBERGLASS ANTI-CRACHING MESH WITH DRYBOND CEMENTITIOUS BONDER COAT & POLYBOND
CEMENT ACRYLIC TOP COAT.
NO. DATE DESCRIPTION
A 4/11/23 OWNER REQUESTED
CHANGE
1/4" = 1'-0"1BUILDING SECTION 1B
1/4" = 1'-0"2BUILDING SECTION 2B
A
A
DOOR SCHEDULE NOTES
1. DO NOT SCALE DRAWINGS.
2. SEE GENERAL NOTES FOR ADDITIONAL INFORMATION.
3. ALL EXTERIOR DOORS SHALL BE FULLY WEATHER STRIPPED, FLASHED,
AND WEATHER TIGHT.
4. ALL GLAZING IN EXTERIOR DOORS SHALL BE DUAL, LOW-E GLAZING AND
SHALL BE FULLY TEMPERED AS REUIRED PER C.R.C. SECTION R327.8.
REFER TO THE WINDOW SCHEDULE NOTES FOR ADDITIONAL LOCATIONS
REQUIRING FULLY TEMPERED GLAZING, PER C.R.C. SECTION R308.4.
5. THE SYMBOL "TG" INDICATES TEMPERED GLASS AND SHALL BE ETCHED ON
THE GLASS.
6. REFER TO INTERIOR DESIGN (I.D.) DRAWINGS FOR ALL INTERIOR DOOR
STYLES, FINISHES, AND HARDWARE SPECIFICATIONS.
7. DOOR OVER 6' - 8" SHALL HAVE 2 PAIR OF HINGES. FINISH AS SELECTED
BY INTERIOR DESIGNER, ARCHITECT, AND/OR OWNER.
8. ALL OUT SWINGING DOORS SHALL HAVE NON REMOVABLE PIN HINGES.
9. SEAL ALL DOORS WITHIN 56 HOURS OF ARRIVAL ON SITE.
10. ALL EXTERIOR DOORS TO BE MANUFACTURED BY KOLBE & KOLBE (OR
APPROVED EQUAL) WITH TRUE DIVIDED LITES - U.N.O.
11. REFER TO EXTERIOR ELEVATIONS FOR DESIGN OF EXTERIOR DOORS -
U.N.O.
12. ALL DOOR SIZES TO BE FIELD VERIFIED PRIOR TO PLACING ORDER.
13. A REPRESENTATIVE FROM THE DOOR MANUFACTURER TO FIELD VERIFY
THAT ALL EXTERIOR DOORS HAVE BEEN INSTALLED AND FLASHED
PROPERLY PRIOR TO INSTALLATION OF ANY INTERIOR OR EXTERIOR FINISH
MATERIALS.
14. ALL INTERIOR DOORS TO BE CUSTOM MANUFACTURED AND ARE TO BE
STAINE GRADE - U.N.O. REFER AND VERIFY WITH INTERIOR DESIGN
DRAWINGS.
15. MAXIMUM SIZE OF 1" FOR MUNTIN BARS FOR ALL DOOR BREAK-UPS.
16. ALL GLAZING (FENESTRATION) SHALL BE INSTALLED WITH A CERTIFYING
LABEL ATTACHED, SHOWING THE "U" VALUE, IN COMPLIANCE WITH
STANDARDS OF THE U.S. CONSUMER PRODUCT SAFETY COMMISSION.
MANUFACTIRERS TO SUPPLY CERTIFICATE OF COMPLIANCE TO THE OWNER.
FENESTRATIONS MUST HAVE TEMPORARY AND PERMANENT LABELS.
17. AVERAGE GLAZING U-FACTOR SHALL COMPLY WITH THE TITLE-24 ENERGY
CALCULATION FORMS AND MANDATORY REQUIREMENTS FOR ENERGY
COMPLIANCE.
18. AVARAGE GLAZING SOLAR HEAT GAIN COEFFICIENT (S.H.G.C.) SHALL
COMPLY WITH THE TITLE-24 ENERGY CALCULATION FORMS AND
MANDATORY REQUIREMENTS FOR ENERGY COMPLIANCE.
19. DOORS THAT PROVIDE DIRECT ACCESS TO THE POOL AND SPA SHALL BE
PROVIDED WITH THE BARRIER COMPLIANT WITH STATE AND LOCAL POOL
BARRIER ORDINANCE. THE MOST STRINGENT CODE REQUIREMENT SHALL
PREVAIL.
20. EACH PANE OF SAFETY GLASS INSTALLED IN HAZARDOUS LOCATIONS
SHALL BE IDENTIFIED (ACID ETCHED, SAND BLASTED, CERAMIC FIRED, ETC.)
BY A MANUFACTURER'S DESIGNATION, THE MANUFACTURER OR INSTALLER
AND THE SAFETY GLAZING STANDARD WHICH IT COMPLIES. MULTI-PANE
ASSEMBLIES SHALL BE IDENTIFIED PER C.R.C. R308.1.
21. GLAZING IN SWINGING, SLIDING, BI-FOLDING DOORS 9 SQUARE FEET OR
LESS SHALL BE A MINIMUM CATEGORY CLASSIFICATION OF I (CPSC 16 CFR
1201) AND II (CPSC 16 CFR 1201) WHEN MORE THAN 9 SQUARE FEET OR
SLIDING [TABLE R308.3.1 (1), R308.3.1].
22. GLAZING IN DOOR AND ENCLOSURES FOR HOT TUBS, WHIRPOOLS, SAUNAS,
STEAM ROOMS, BATHROOMS, SHOWERS LESS THAN 60" ABOVE THE
STANDING SURFACE SHALL HAVE A MINIMUM CATEGORY CATEGORY
CLASSIFICATION OF II (CPSC 16 CFR 1201) PER C.R.C. TABLE R308.3.1 (1),
R308.4.5.
23. GLAZING WITHIN 24" ARC OF EITHER VERTICAL EDGE OF THE DOOR AND
LESS THAN 5' FROM THE WALKING SURFACE SHALL BE SAFETY GLAZED.
WINDOW SCHEDULE NOTES
1. DO NOT SCALE DRAWINGS.
2. SEE GENERAL NOTES FOR ADDITIONAL INFORMATION.
3. ALL WINDOWS SHALL BE FULLY WATHER STRIPPED, FLASHED, AND
WEATHER TIGHT.
4. FOR HEAT TRANSFER COEFFICIENT (U) AND SOLAR HEAT GAIN COEFFICIENT
(SHGC) OF ALL GLAZING REFER TO TITLE 24 TABLES, WHICH HAVE
PRIORITY OVER THE ARCHITECTURAL WINDOW SCHEDULE.
5. ALL GLAZING IN EXTERIOR WINDOWS SHALL BE DUAL, LOW-E GLAZING AND
SHALL BE FULLY TEMPERED, AS REQUIRED PER 2013 C.R.C. SECTION
R308.4, AT THE FOLLOWING LOCATIONS:
A. GLAZING IN ALL FIXED AND OPERABLE PANELS OF SWINGING, SLIDING
AND BI-FOLDING DOORS.
B. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT TO A
DOOR WHERE THE NEAREST VERTICAL EDGE IS WITHIN 24-INCH ARC OF
THE DOOR ON A CLOSED POSITION AND WHOLE BOTTOM EDGE IS LESS
THAN 60 INCHES ABOVE THE FLOOR OR WALKING SURFACE.
C. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL THAT MEETS ALL
OF THE FOLLOWING:
a. EXPOSED AREA OF AN INDIVIDUAL PANE LARGER THAN 9 SQUARE
FEET.
b. BOTTOM EDGE LESS THAN 18 INCHES ABOVE THE FLOOR.
c. TOP EDGE MORE THAN 36 INCHES ABOVE THE FLOOR
d. ONE OR MORE WALKING SURFACES WITHIN 36 INCHES HORIZONTALLY
OF THE GLAZING.
D. ALL GLAZING IN RAILINGS REGARDLESS OF AN AREA OR HEIGHT ABOVE
A WALKING SURFACE. INCLUDED ARE STRUCTURAL BALUSTER PANELS
AND NONSTRUCTURAL INFILL PANELS.
E. GLAZING IN ENCLOSURES FOR OR WALLS FACING HOT TUBS, WIRLPOOLS,
SAUNAS, STEAM ROOMS, BATHTUBS AND SHOWERS WHERE THE BOTTOM
EXPOSED EDGE OF THE GLAZING IS LESS THAN 60 INCHES MEASURED
VERTUCALLY ABOVE ANY STANDING OR WALKING SURFACE.
F. GLAZING IN WALLS AND FENCES ADJACENT TO INDOOR AND OUTDOOR
SWIMMING POOLS, HOT TUBS AMD STAS WHERE THE BOTTOM EDGE OF
THE GLAZING IS LESS THAN 60 INCHES ABOVE A WALKING SURFACE AND
WITHIN 60 INCHES OFF THE WATER EDGE, MEASURED HORIZONTALLY AND
IN A STRAIGHT LINE. THIS SHALL BE APPLY TO SINGLE GLAZING AND ALL
PANES IN MULTIPLE GLAZING.
G. GLAZING ADJACENT TO STAIRWAYS, LANDINGS AND RAMPLS WITHIN 36
INCHES HORIZONTALLY OF A WALKING SURFACE WHEN THE EXPOSED
SURFACE OF THE GLAZING IS LESS THAN 60 INCHES ABOVE THE PLANE
OF THE ADJACENT WALKING SURFACE.
H. GLAZING ADJACENT TO STAIRWAYS WITHIN 60 INCHES HORIZONTALLY OF
THE BOTTOM TREAD OF A STAIRWAY IN ANY DIRECTION WHEN THE
EXPOSED SURFACE OF THE GLAZING IS LESS THAN 60 INCHES ABOVE
THE NOSE OF THE TREAD.
6. THE SYMBOL "TG" INDICATES TEMPERED GLASS AND SHALL BE ETCHED ON
THE GLASS, WHERE REQUIRED PER ITEMS 5A THRU 5H ABOVE.
7. ALL EXTERIOR DOORS TO BE MANUFACTURED BY KOLBE & KOLBE (OR
APPROVED EQUAL) WITH TRUE DIVIDED LITES - U.N.O.
8. VERIFY WITH OWNER WHICH OPERABLE WINDOWS ARE TO RECEIVE
SCREENS.
9. REFER TO EXTERIOR ELEVATIONS FOR WINDOW STYLES, OPERABILITY,
NUMBER AND CONFIGURATION OF BREAK-UPS.
10. REFER TO EXTERIOR ELEVATIONS FOR TYPICAL MUNTIN SPACING.
11. ALL WINDOW SIZES TO BE FIELD VERIFIED PRIOR TO PLACING ORDER.
12. A REPRESENTATIVE FROM THE WINDOW MANUFACTURER TO FIELD VERIFY
THAT ALL WINDOWS HAVE BEEN INSTALLED AND FLASHED PROPERLY
PRIOR TO INSTALLATION OF ANY INTERIOR OR EXTERIOR FINISH
MATERIALS.
13. MAXIMUM SIZE OF 1" FOR MUNTIN BARS FOR ALL WINDOW BREAK-UPS.
14. ALL GLAZING (FENESTRATION) SHALL BE INSTALLED WITH A CERTIFYING
LABEL ATTACHED, SHOWING THE "U" VALUE, IN COMPLIANCE WITH
STANDARDS OF THE U.S. CONSUMER PRODUCT SAFETY COMMISSION.
MANUFACTIRERS TO SUPPLY CERTIFICATE OF COMPLIANCE TO THE OWNER.
FENESTRATIONS MUST HAVE TEMPORARY AND PERMANENT LABELS.
15. AVERAGE GLAZING U-FACTOR SHALL COMPLY WITH THE TITLE-24 ENERGY
CALCULATION FORMS AND MANDATORY REQUIREMENTS FOR ENERGY
COMPLIANCE.
16. AVARAGE GLAZING SOLAR HEAT GAIN COEFFICIENT (S.H.G.C.) SHALL
COMPLY WITH THE TITLE-24 ENERGY CALCULATION FORMS AND
MANDATORY REQUIREMENTS FOR ENERGY COMPLIANCE.
17. THE LOAD RESISTANCE OF GLASS UNDER UNIFORM LOAD SHALL BE
DETERMINED IN ACCORDANCE WITH ASTM 1300.
18. BATHROOM AND SERVICE ROOM MINIMUM WINDOW AREAS SHALL NOT BE
LESS THAN 3 SQUARE FEET AND 50% OPERABLE OR PROVIDE A
MECHANICAL VENTILATION SYSTEM EXHAUSTED TO THE OUTSIDE CAPABLE
OF PROVIDING 50 CUBIC FEET PER MINUTE FOR INTERMITTENT VENTING 25
CUBIC FEET PER MINUTE FORCONTINIOUS VENTILATION PER C.R.C. R303.3.
19. EACH PANE OF SAFETY GLASS INSTALLED IN HAZARDOUS LOCATIONS
SHALL BE IDENTIFIED (ACID ETCHED, SAND BLASTED, CERAMIC FIRED,
ETC.) BY A MANUFACTURER'S DESIGNATION, THE MANUFACTURER OR
INSTALLER AND THE SAFETY GLAZING STANDARD WHICH IT COMPLIES.
MULTI-PANE ASSEMBLIES SHALL BE IDENTIFIED PER C.R.C. R308.1.
2'-6"
15'-1 1/2"
EQ EQ EQ EQ EQ
TYP.
2 1/2"
TYP.
2 1/2"
TYP.
2 1/2"
℄℄℄℄℄℄
ELEVATION
EQ EQ EQ EQ EQ EQ
18'-2 1/4"
℄℄℄℄℄
TYP
2 1/2"5"
TYP
5"
EQ
6'-2"
EQ
6.66°
TYP
2 1/2"
℄
℄
℄
IN
T
E
R
I
O
R
2'-4 1/2"
SECTION
FIN. FL.
6'-1 1/2"
8'-0"
13'-0"
EQ EQ EQ EQ
TYP.
2 1/2"
TYP.
2 1/2"
TYP.
2 1/2"
T.O. SHTG 2ND FL.
HDR. HT. 2
℄℄℄℄℄
TYP.
2 1/2"TYP.
2 1/2"
TYP.
2 1/2"
1'-6"
8'-0"
HDR. HT. 2
T.O. SHTG 2ND FL.
ALIGN WITH DOOR 202
8'-4"
3"
12"
EQ EQ EQ
℄℄℄℄
4 1/2"2'-5 1/2"
TYP.
2 1/2"
T
Y
P.
2
1
/
2
"
ALIGN WITH DOOR 203
8'-4"
3"
12"
EQ EQ EQ
℄℄℄℄
4 1/2"2'-5 1/2"
TYP.
2 1/2"
T
Y
P
.
2
1
/
2"
TYP
2 1/2"
9'-0"
GLASS
ENTRY
DOOR
5"
GARAGE WALL
15'-0"
3'-2"
EQ
AVG. TOC
FIN. FL.
1'-0"
6'-1 1/2"
EQ
2'-4 1/2"
LICENCE STAMP:
THESE DRAWINGS ARE THE PROPERTY OF OATMAN
ARCHITECTS AND SHALL NOT BE MODIFIED OR USED ON ANY
OTHER PROJECT OR SITE WITHOUT WRITTEN PERMISSION.
IT IS THE OWNER'S AND IT'S GENERAL CONTRACTOR'S
RESPONSIBILITY, PRIOR TO OR DURING CONSTRUCTION, TO
NOTIFY THE ARCHITECT IN WRITING OF ANY PERCEIVED
ERRORS OR OMISSIONS IN THE PLANS AND/ OR GENERAL
NOTES OF WHICH A CONTRACTOR THOROUGHLY
KNOWLEDGEABLE WITH THE BUILDING CODES AND MEANS &
METHODS OF CONSTRUCTION SHOULD REASONABLY BE
AWARE. WRITTEN INSTRUCTIONS ADDRESSING SUCH
PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED
FROM THE ARCHITECT PRIOR TO THE OWNER OR OWNER'S
CONTRACTOR PROCEEDING WITH THE WORK. THE OWNER
WILL BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION
IF THESE PROCEDURES ARE NOT FOLLOWED.
NOTE: THE ORIGINAL SIZE OF THIS DRAWING SHEET IS: 36"X48"
PROJECT NUMBER:
SUBMITTAL:
REVISION:
DATE DESCRIPTION
PERMIT NUMBER:
CLIENT:
4/11/2023 1:55:41 PM
A9.0
SCHEDULES
2022001
RI
Z
K
O
R
E
S
I
D
E
N
C
E
30
6
V
I
A
L
I
D
O
N
O
R
D
NE
W
P
O
R
T
B
E
A
C
H
,
C
A
9
2
6
6
3
DE
S
I
G
N
D
E
V
E
L
O
P
M
E
N
T
CAMILLE AND JOUMANA RIZKO
PRINCIPAL: HOMER
OATMAN
DRAWN BY: Author
DOOR SCHEDULE
# WIDTH HEIGHT OPERATION TEMP EGRESS ROOM DESCRIPTION
001 16'-0" 3'-6" EXTERIOR SLIDER BOAT STORAGE PAIR OF 8'-0" SLIDING DR PANELS - TOP HUNG SYSTEM WITH 1-INCH INSET INTO CEILING
101 15'-5 85/256" 8'-0" EXTERIOR ROLL-UP DR 3-CAR GARAGE
102 7'-8 171/256" 8'-0" EXTERIOR ROLL-UP DR 3-CAR GARAGE
103 3'-0" 8'-0" EXTERIOR SWING YES 3-CAR GARAGE FROSTED GLASS
104 2'-8" 8'-0" EXTERIOR SWING YES BA.2
105 2'-8" 8'-0" EXTERIOR SWING YES BACK KITCHEN/PANTRY
106 27'-0" 9'-0" EXTERIOR MULTI-SLIDER POCKET YES GREAT ROOM 8 PANELS - DOUBLE SIDE POCKET (4 PANELS EACH POCKETING EACH SIDE)
107 3'-0" 6'-8" INTERIOR SWING 3-CAR GARAGE 20 MIN. FIRE-RATED, SELF-CLOSING AND SELF-LATCHING
108 3'-0" 8'-0" INTERIOR SWING POWDER
109 3'-0" 8'-0" INTERIOR SWING ELEV.
110 2'-6" 8'-0" INTERIOR SWING BACK KITCHEN/PANTRY HIDDEN DOOR INSET IN WOOD PANELING PER INTERIORS
111 2'-8" 8'-0" INTERIOR SWING GUEST BEDROOM 2
112 2'-8" 8'-0" INTERIOR POCKET CL.2
113 2'-8" 8'-0" INTERIOR POCKET BA..2
201 13'-0" 8'-0" EXTERIOR MULTI-SLIDER POCKET YES YES PRIMARY BEDROOM 4 PANELS - SINGLE SIDE POCKET
202 8'-4" 8'-0" EXTERIOR SWING YES YES BEDROOM 4 SWING DR WITH DOUBLE SIDE LIGHTS - EQUAL PANELS
203 8'-4" 8'-0" EXTERIOR SWING YES YES BEDROOM 5 SWING DR WITH DOUBLE SIDE LIGHTS - EQUAL PANELS
204 4'-6" 8'-0" INTERIOR PAIR OF SWING PRIMARY BEDROOM WOOD PANEL JAMB AND DOOR PER INTERIORS
205 3'-0" 8'-0" INTERIOR POCKETING PRIMARY WIC INTERIOR SWING
206 2'-8" 8'-0" INTERIOR SWING PRIMARY BATH
208 3'-0" 8'-0" INTERIOR SWING ELEV.
209 2'-8" 8'-0" INTERIOR SWING BEDROOM 3
210 2'-8" 8'-0" INTERIOR SWING CL.3
211 2'-8" 8'-0" INTERIOR SWING BA.3
212 2'-8" 8'-0" INTERIOR SWING BEDROOM 4
213 2'-8" 8'-0" INTERIOR SWING CL.4
214 2'-8" 8'-0" INTERIOR SWING BA.4
215 2'-8" 8'-0" INTERIOR SWING BEDROOM 5
216 6'-0" 8'-0" INTERIOR BI-SLIDER CL.5
217 2'-8" 8'-0" INTERIOR SWING BATH 5
218 2'-8" 8'-0" INTERIOR POCKET BATH 5
WINDOW SCHEDULE
# WIDTH HEIGHT HEADER HEIGHT OPERATION TEMP EGRESS COMMENTS
1A 2'-6" 4'-6" 8'-0" CASEMENT YES GUEST BEDROOM 2
1B 2'-6" 4'-6" 8'-0" CASEMENT YES GUEST BEDROOM 2
2A 2'-6" 4'-6" 8'-0" CASEMENT BEDROOM 5
2B 4'-0" 4'-6" 8'-0" DOUBLE CASEMENT OFFICE/DEN
2C 4'-0" 4'-6" 8'-0" DOUBLE CASEMENT LAUNDRY
2D 2'-6" 4'-6" 8'-0" CASEMENT PRIMARY BEDROOM
2E 2'-6" 4'-6" 8'-0" CASEMENT PRIMARY BEDROOM
2F 2'-6" 2'-0" 8'-0" AWNING P.TOILET
2G 2'-6" 2'-0" 8'-0" AWNING PRIMARY WIC
2H 2'-6" 2'-0" 8'-0" AWNING PRIMARY WIC
2J 2'-6" 4'-6" 8'-0" CASEMENT YES BEDROOM 3
2K 2'-6" 4'-6" 8'-0" CASEMENT YES BEDROOM 3
2L 2'-0" 2'-0" 8'-0" AWNING BA.3
2M 2'-0" 2'-0" 8'-0" AWNING BA.4
2N 2'-6" 4'-6" 8'-0" CASEMENT BEDROOM 4
2P 2'-6" 4'-6" 8'-0" CASEMENT BEDROOM 4
2Q 1'-6" 3'-0" 7'-0" CASEMENT YES BATH 5
DOOR LEGEND
WINDOW LEGEND
GLAZING SPECIFICATION
MINIMUM GLAZING REQUIREMENTS PER TITLE 24:
- U-FACTOR = 0.32
- SHGC = 0.23
NOTES:
DOOR HEIGHT AND WIDTH PER SCHEDULE
NOTES:
WINDOW HEIGHT AND WIDTH PER SCHEDULE
NO. DATE DESCRIPTION
15'-6"
7'-9"
1/2" = 1'-0"1WINDOW WALL 2AA
1/2" = 1'-0"7WINDOW WALL 1BB
1/2" = 1'-0"2WINDOW WALL 2BB
1/2" = 1'-0"3WINDOW WALL 2CC
1/2" = 1'-0"4WINDOW WALL 2DD
1/2" = 1'-0"5WINDOW WALL 2EE
1/2" = 1'-0"6WINDOW WALL 1AA