HomeMy WebLinkAboutPA2022-0290_20221227_ARCHITECTUAL PLANS_42x30LOT 70
TRACT 907
M.M. 28/25-36
LOT 71
LOT 69
VI
A
L
I
D
O
N
O
R
D
℄
N29°00'00"E 90.00'
N6
1
°
0
0
'
0
0
"
W
3
5
.
0
0
'
N29°00'00"E 90.00'
N6
1
°
0
0
'
0
0
"
W
3
5
.
0
0
'
BASIS OF BEARINGS
BENCHMARK INFORMATION
BENCHMARK NO: NB3-21-92
DESCRIBED BY OCS 2002 - FOUND 3 3\4" OCS ALUMINUM BENCHMARK DISK
STAMPED "NB3-21-92", SET IN THE NORTHWEST CORNER OF A 4 FT. BY
10 FT. CONCRETE CATCH BASIN. MONUMENT IS LOCATED IN THE SOUTHWEST
CORNER OF THE INTERSECTION OF VIA LIDO NORO AND VIA KORON,
40 FT. WESTERLY OF THE CENTERLINE OF VIA KORON AND 20 FT. SOUTHERLY
OF THE CENTERLINE OF VIA LIDO NORO. MONUMENT IS SET LEVEL WITH THE
SIDEWALK.
ELEVATION: 11.912 FEET (NAVD88), YEAR LEVELED 2015
VICINITY MAP
GRAPHIC SCALE
LEGAL DESCRIPTION
REAL PROPERTY IN THE CITY OF NEWPORT BEACH, COUNTY OF
ORANGE, STATE OF CALIFORNIA, DESCRIBED AS FOLLOWS:
LOT 70 OF TRACT, IN THE CITY OF NEWPORT BEACH, COUNTY OF
ORANGE, STATE OF CALIFORNIA, AS PER MAP RECORDED IN BOOK 28,
PAGE 25-36 OF MISCELLANEOUS MAPS, IN THE OFFICE OF THE COUNTY
RECORDER OF SAID COUNTY.
PAUL D. CRAFT, P.L.S. 8516 DATE
NOTE: SECTION 8770.6 OF THE CALIFORNIA BUSINESS AND PROFESSIONS CODE
STATES THAT THE USE OF THE WORD CERTIFY OR CERTIFICATION BY A
LICENSED LAND SURVEYOR IN THE PRACTICE OF LAND SURVEYING OR THE
PREPARATION OF MAPS, PLATS, REPORTS, DESCRIPTIONS OR OTHER SURVEYING
DOCUMENTS ONLY CONSTITUTES AN EXPRESSION OF PROFESSIONAL OPINION
REGARDING THOSE FACTS OR FINDINGS WHICH ARE THE SUBJECT OF THE
CERTIFICATION AND DOES NOT CONSTITUTE A WARRANTY OR GUARANTEE,
EITHER EXPRESSED OR IMPLIED.
LICENSE RENEWAL DATE 12/31/20
S
T
ATE OF CA L I F O R N IA
PAUL
D O M I NICK
C
R
A
FT
Exp. 12/31/20
No. 8516PROFESSIONALLAND
S
U
R
V
E
YOR
TITLE REPORT/EASEMENT NOTES
604 VIA LIDO NORD
NEWPORT BEACH, CA 92663
APN:423-231-02
NO TITLE REPORT PROVIDED.
CONCRETE SURFACE
1 1
TO
P
O
G
R
A
P
H
I
C
M
A
P
60
4
V
I
A
L
I
D
O
N
O
R
D
NE
W
P
O
R
T
B
E
A
C
H
,
C
A
9
2
6
6
3
AP
N
:
4
2
3
-
2
3
1
-
0
2
LEGEND
EXISTING ELEVATION( )
AC ASPHALT PAVEMENT
TEMPORARY BENCHMARKTBM
BLOCK WALL
LC CENTERLINE
GM GAS METER
FS
FL
FINISHED SURFACE
FLOWLINE
SET ON A WATER METER (WM)
HU
N
T
I
N
G
T
O
N
B
E
A
C
H
,
C
A
L
I
F
O
R
N
I
A
9
2
6
4
6
PH
O
N
E
:
(
7
1
4
)
4
8
8
-
5
0
0
6
F
A
X
:
(
7
1
4
)
3
3
3
-
4
4
4
0
A
P
E
X
L
S
I
N
C
@
G
M
A
I
L
.
C
O
M
ELEVATION = 12.83 FEET
SURVEYOR OR ENGINEER SHALL PERMANENTLY MONUMENT PROPERTY
CORNERS OR OFFSETS BEFORE STARTING GRADING.
PLEASE CALL PAUL CRAFT @ 714-488-5006 TO SCHEDULE.
SURVEYOR'S NOTES
FF FINISH FLOOR
NG NATURAL GROUND
TOP OF CURBTC
SEARCHED, FOUND NOTHING; SET
NOTHING
THE BEARINGS SHOWN HEREON ARE BASED ON THE CENTERLINE OF VIA LIDO NORD,
BEING N61°00'00"W PER TRACT 907, M/M 28/25-36, RECORDS ON FILE IN THE OFFICE OF
THE ORANGE COUNTY SURVEYOR.
BFP BACK FLOW PREVENTOR
CLM COLUMN
EG EDGE OF GUTTER
WATER METERWM
WOODEN FENCE (WDF)
BRICK SURFACE
TILE SURFACE
TOP OF DECKTD
TOP OF STEPTS
PLANTER AREAPA
1/14/2020
UP
F.Y.S.B.
4' - 0"
VI
A
L
I
D
O
N
O
R
D
EXISTING BUILDING
(NOT A PART)
EXISTING BUILDING
(NOT A PART)
CENTERLINE OF STREET
22' - 6"
F.O.F.
4' - 0"
4' - 2"
F.O.F.
8'
-
0
"
8'
-
2
"
F.O.F.
4'
-
0
"
4'
-
1
"
F.O.F.
3'
-
0
"
3'
-
1
"
F.O.F.
2'
-
0
"
2'
-
2
"
F.O.F.
3'
-
0
"
3'
-
1
"
F.O.F.
15' - 0"
15' - 1"
F.O.F.
3'
-
0
"
3'
-
1
"
S.
Y
.
S
.
B
.
3'
-
0
"
F.Y.S.B.
10' - 0"
S.Y.S.B.
3'
-
0
"
(E.) DOCK
NE
W
P
O
R
T
H
A
R
B
O
R
3'
-
0
"
DRIVEWAY WIDTH
18
'
-
0
"
3'
-
0
"
PLANTED AREA
PLANTED AREA
DN.
DN.
PLANTED AREAPLANTED AREA
CLR.
22
'
-
5
1
/
4
"
CLR.
20' - 9 3/8"
UP
11.51' T.O.S.
13.16' T.O.S.11.51' T.O.S.
2-CAR GARAGE
POWDER
BEDROOM #1
BATH #1
FOYER
GREAT ROOM
DININGKITCHEN
PANTRYSTAIRS
SLOPE PER CIVIL
LOT 70
TRACT 907
M.M. 28/25-36
NEW TWO-STORY
SINGLE FAMILY RESIDENCE
N6
1
°
0
0
'
0
0
"
W
35
.
0
0
'
N6
1
°
0
0
'
0
0
"
W
35
.
0
0
'
N29°00'00"E 90.00'
N29°00'00"E 90.00'
4'
-
1
1
/
4
"
3'
-
1
1
3
/
4
"
9'
-
9
7
/
8
"
2'
-
7
3
/
4
"
3'
-
0
1
/
8
"
PATIO
ENTRY
1
1
1
1
2
2
3
3
4
5
6
7
8
9
9
10 10
1010
10
11
12 12
13 13
14
14PLANTED AREA
PLANTED AREA
15
WATER FEATURE
16
8
17
17
17
18
18
19.13' T.O.W.17.50' T.O.W.14.68' T.O.W.
15.01' T.R.
15.01' T.R.
14.68' T.O.W.17.50' T.O.W.
17.50' T.O.W.
17.50' T.O.W.
10
19
20
ROOM TAGROOM NAME
?
1
10.00'SPOT ELEVATION
KEYNOTE TAG
REVISION TAG
PROPERTY LINE TAG90 00' 00"20.00'N E
FIREPIT -AS SELECTED TO BE LISTED AND APPROVED, VERIFY W/.
OWNER –PROVIDE POWER AND GAS AS REQUIRED –INSTALL AND
MAINTAIN CLEARANCES PER MFGR. AND SECTION 308 OF CFC
RECESSED MAIN SERVICE PANEL -400 AMP MAX. (MAINTAIN 36" CLEAR FROM FACE
OF PANEL TO ANY OBSTRUCTION) –GC TO COORDINATE W/. UTILITY COMPANY
A/C CONDENSER / HEAT PUMP -TO BE IN COMPLIANCE OF SECTION 307.3 OF CPC AS
SELECTED, VERIFY W/. OWNER -SIZE TBD, SEE T-24 ENERGY REPORT FOR MORE INFO –
PROVIDE POWER AND SOUND DAMPENING PAD AS REQ’D. –INSTALL AND MAINTAIN
REQUIRED CLEARANCES PER MFGR. INSTRUCTION
VERTICAL STORM DRAIN PIPE IN-WALL / OVERFLOW -MTL. PIPE PER
CHAPTER 11 OF CPC, SIZE PER TABLE 1103.1 (MIN. 2”DIA. PIPE & TYP. 3”DIA. PIPE) –
SEE CIVIL DWGS. FOR TERMINATION DTLS. ABV. OR BLW. GROUND. VERIFY ALL
TERMINATION POINTS, TYPE AND DETAILS W/. CIVIL PRIOR TO POURING THE CONCRETE
SLAB
OVERFLOW
DRAINLINE
UP
EXT. STAIRS -MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE ARTIFICIAL LIGHT
SOURCE AT THE TOP LANDING AND FOR STAIR TO THE BASEMENT AT BOTH TOP
AND BOTTOM LANDING (R303.8) -REF. DTL. 3/AD-1 -VERIFY TREADS DEPTH AND
RISERS HT. W/. CIVIL AND LANDSCAPE DWGS
DIMENSION NOTE:
ALL DIMENSIONS ARE TO FACE OF SHEATHING (EXT. WALLS) OR FACE OF STRUCTURE (F.O.S.) TYP. U.N.O. ROUNDED TO THE
NEAREST 1/8" AND INTERIOR PARTITIONS ARE DIMENSIONED FROM FACE OF STRUCTURE TO FACE OF STRUCTURE (F.O.S.)
U.N.O. -CONTACT ARCHITECT IN WRITING FOR ANY CLARIFICATION OF NOTED DIMENSIONS, DO NOT SCALE PLANS.
GENERAL NOTE:
SEE SHEET A-3.0 FOR ROOF PLAN INFORMATION NOT SHOWN ON THIS SHEET (INCLUDING EAVE DETAILS AND PROJECTION
DISTANCES).
C.N.B. NOTES:
1. ISSUANCE OF A BUILDING PERMIT BY THE CITY OF NEWPORT BEACH DOES NOT RELIEVE APPLICANTS OF THE LEGAL
REQUIREMENTS TO OBSERVE COVENANTS, CONDITIONS AND RESTRICTIONS WHICH MAY BE RECORDED AGAINST THE PROPERTY
OR TO OBTAIN PLANS YOU SHOULD CONTACT YOUR COMMUNITY ASSOCIATIONS PRIOR TO COMMENCEMENT OF ANY
CONSTRUCTION AUTHORIZED BY THIS PERMIT.
2. PRIOR TO PERFORMING ANY WORK IN THE CITY RIGHT-OF-WAY AN ENCROACHMENT PERMIT MUST BE OBTAINED FROM THE
PUBLIC WORKS DEPARTMENT.
3. A CAL-OSHA PERMIT IS REQUIRED FOR EXCAVATIONS DEEPER THAN 5' AND FOR SHORING AND UNDERPINNING.
4. ELECTRICAL SERVICE TO BE UNDERGROUND FOR NEW CONSTRUCTION, REPLACEMENT BUILDING OR ADDITIONS TO AN
EXISTING BUILDING EXCEEDING 50% OF THE GROSS FLOOR AREA OF THE EXISTING BUILDING. (NBMC 12.32.015)
5. FIELD INSPECTOR TO REVIEW AND APPROVE UNDERGROUND ELEC. SERVICE REQUIREMENT PRIOR TO CONCRETE PLACEMENT.
6. EDISON COMPANY APPROVAL IS REQUIRED FOR METER LOCATION PRIOR TO INSTALLATION.
LANDSCAPE NOTES:
1. ENCROACHMENT PERMIT REQ'D. FOR ANY WORK PROPOSED IN THE PUBLIC R.O.W.
2. IF APPLICABLE, REF. PRELIMINARY LANDSCAPE PLANS, FOR ALL HARDSCAPE & PLANTING AREAS WITH RESPECTIVE HEIGHTS
AND MATERIALS.
POOL:
1. PROVIDE AN ALARM FOR DOORS AND WINDOWS WITH SILL HEIGHTS LESS THAN 60-INCHES ABV.F.F. OF THE DWELLING THAT
FORMS A PART OF THE POOL ENCLOSURE. THE ALARM SHALL BE LISTED AS A WATER HAZARD ENTRANCE ALARM IN
ACCORDANCE WITH UL 2017. THE DEACTIVATION SWITCH SHALL BE AT LEAST 60" ABOVE THE FLOOR IF THE RESIDENCE IS NOT
REQUIRED TO BE ACCESSIBLE. (CBC 3109 & ISPSC 305.4)
2. SUCTION OUTLETS SHALL BE DESIGNED AND INSTALLED WITH SUCTION ANTIENTRAPMENT GRATE IN ACCORDANCE WITH
ANSI/APSP-16 PER CBC 3109 SECTION (B) OF 115928. SUCTION ENTRAPMENT AVOIDANCE FOR POOL AND SPA SHALL BE
PROVIDED IN ACCORDANCE WITH APSP-7 PER ISPSC SECTION 310.
3. PROVIDE POWER SAFETY COVER IN COMPLIANCE WITH ASTM F1346-91 FOR POOL & SPA (CBC 3109 SECTION (3) OF 115922 &
ISPSC 305).
4. POOL ENCLOSURE FENCE SHALL BE 60-INCHES MIN. ABV. FS/NG MEASURED ON THE SIDE THAT FACES AWAY FROM
SWIMMING POOL W/. MAX VERTICAL CLEARANCE OF 2-INCHES BETWEEN FS/NG AND BOTTOM OF THE FENCE/BARRIER
MEASURED ON THE SIDE OF FENCE THAT FACES AWAY FROM SWIMMING POOL. OPENING, GAP, AND VOID IN ENCLOSURE FENCE
OR GATE SHALL NOT ALLOW THE PASSAGE OF 4-INCHES DIAMETER SPHERE OR LARGER. OUTSIDE SURFACE (FACING AWAY
FROM SWIMMING POOL) OF THE POOL ENCLOSURE INCLUDING THE GATE TO BE FREE OF PROTRUSIONS, CAVITIES, OR OTHER
PHYSICAL CHARACTERISTICS THAT WOULD SERVE AS HANDHOLDS OR FOOTHOLDS WHICH COULD ENABLE A CHILD FIVE YEARS
OLD OR YOUNGER TO CLIMB OVER. (CBC 3109 & ISPSC 305)
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
SITE PLAN NOTESA
ANNOTATION LEGENDB
KEYNOTESC
BRANDON ARCHITECTS
11.30.22
ARCHITECTURAL
SITE PLAN
AN
T
E
P
A
R
A
R
E
S
I
D
E
N
C
E
PAUL ANTEPARA
604 VIA LIDO NORD
NEWPORT BEACH, CA 92663
HOA SUBMITTAL
604 VIA LIDO NORD
NEWPORT BEACH, CA 92663
A-0.0
TBD
KENNEDY YEAR
PROJECT NORTHTRUE NORTH
1/4" = 1'-0"1 ARCHITECTURAL SITE PLAN
NO. REVISION DATE
1 PROPERTY LINE - REF. SURVEY
2 FRONT YARD SETBACK
3 SIDE YARD SETBACK
4 CURB
5 GUTTER
6 CENTERLINE OF STREET - REF. SURVEY
7 (E.) CABLE TV JUNCTION BOX - REF. SURVEY
8 (E.) WATER METER LOCATION - REF. SURVEY & CIVIL DWGS.
9 (N.) WOOD GATE - AS SELECTED (MAX. 6' HT. ABOVE NATURAL GRADE)
10 (N.) HARDSCAPE - STONE PAVERS (AS SELECTED), REF. LAND. & CIVIL DWGS.
11 FIREPIT - PROVIDE GAS STUB-OUT & POWER AS REQ'D., REF. LAND. DWGS., VERIFY W/. OWNER
12 (E.) PROPERTY LINE WALL - PROTECT IN PLACE - REF. SURVEY, CIVIL AND LAND. DWGS
13 (N.) PROPERTY LINE WALL - PLASTER FINISH TO MATCH (MAX. 6' ABV. N.G.)
14 STAIRS - MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE AN ILLUMINATION LEVEL OF NOT LESS THAN 1 FOOT CANDLE AS
MEASURED AT THE CENTER OF TREADS AND LANDING WITH ARTIFICIAL LIGHTING (R303.7) - REF. DTL. 1/AD-1.0
15 RECESSED MAIN SERVICE PANEL, 400 AMP MAX. (MAINTAIN 36" CLEAR FROM FACE OF PANEL TO ANY OBSTRUCTION)
16 (E.) GAS METER LOCATION - REF. SURVEY & CIVIL DWGS.
17 OUTLINE OF EXISTING STRUCTURE - TO BE REMOVED - REF. SURVEY
18 EXTERIOR GLASS GUARDRAIL , TEMPERED & LAMINATED - MIN. 42" HIGH ABV.F.F. - <4" MAX. SPHERE OPENING, REF. DTL.
4/AD-1.0
19 (N.) DRIVEWAY PAVERS - REF. LAND. & CIVIL DWGS., SLOPE PER CIVIL
20 (N.) CMU LANDSCAPE COLUMN, REF. LANDSCAPE & CIVIL DWGS.
UP
UP
UP
1345 SF
FIRST FLOOR508 SF
GARAGE
113 SF
ENTRY COURT
34 SF
ENTRY
157 SF
PATIO22
'
-
5
1
/
4
"
1823 SF
SECOND FLOOR 84 SF
MASTER BALCONY
232 SF
2ND FL FRONT
5'
-
5
1
/
4
"
5' - 0"
WATER FEATURE
BBQ
33 SF
PLANTED
10 SF
PLANTED
55 SF
PLANTED
5 SF
PLANTED
12 SF
PLANTED
5' - 0"
1700 SF
SLOPED ROOFS 452 SF
FLAT ROOF
EQ EQ
A
B
5'
-
2
"
21' - 9 1/2"19' - 2 1/2"
1'
-
1
"
OPEN AREA @ FRONT
A 21' -9 1/2" X 5' -2" = 112.59 S.F.
B 19' -2 1/2" X 1' -1" = 20.81 S.F.
1ST FLOOR TOTAL OPEN @ FRONT = 133.4 S.F.
A
B
C
13
'
-
1
1
/
4
"
6'
-
1
1
/
8
"
6'
-
6
5
/
8
"
3'
-
0
"
29
'
-
0
"
3'
-
0
"
21' - 9 1/2"
5' - 6 1/4"
4' - 1 3/4"
OPEN AREA @ FRONT
A 13' -1 1/4" X 4' -1 3/4" = 54.33 S.F.
B 6' -1 1/8" X 5' -6 1/4" = 33.13 S.F.
C 21' -9 1/2" X 6' -6 5/8" = 142.78 S.F.
2ND FLOOR TOTAL OPEN @ FRONT = 230.24 S.F.
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
BRANDON ARCHITECTS
11.30.22
AREA PLANS
AN
T
E
P
A
R
A
R
E
S
I
D
E
N
C
E
PAUL ANTEPARA
604 VIA LIDO NORD
NEWPORT BEACH, CA 92663
HOA SUBMITTAL
604 VIA LIDO NORD
NEWPORT BEACH, CA 92663
A-0.3
TBD
KENNEDY YEAR
1/8" = 1'-0"2 FIRST FLOOR AREA
1/8" = 1'-0"3 SECOND FLOOR AREA
1/8" = 1'-0"1 LANDSCAPE AREA PLAN
1/8" = 1'-0"4 ROOF AREA PLAN
LEGAL DESCRIPTION:
LOT INFORMATION:
ZONED: R-1
SITE AREA:3,150 S.F. BUILDABLE AREA: 2,204 S.F.
TOTAL ALLOWABLE AREA (HOA): 1.7 X 2,204 S.F. = 3,746.8 S.F.
TOTAL ALLOWABLE AREA (CITY): 2 X 2,204 S.F. = 4,408 S.F.
TOTAL OPEN AREA REQUIRED: .15 X 2,204 S.F. = 330.6 S.F.
TOTAL OPEN AREA PROVIDED: 620 S.F. > 330.6 S.F.
TOTAL LANDSCAPE AREA: 115 S.F.
EXISTING BUILDING INFORMATION:
EXISTING SINGLE FAMILY W/ ATTACHED GARAGE TO BE DEMOLISHED
EXISTING S.F. = 3,128 S.F. (5 BEDS. & 4 BATHS TTL.)
ZONING INFORMATION:
FRONT SETBACK: 4 FT.
SECOND FRONTAGE SETBACK: 10 FT.
LEFT SETBACK: 3 FT.
RIGHT SETBACK: 3 FT.
BUILDABLE AREA: 2,204 S.F.
APN: 423 231 02
LOT 70, TRACT NO. 907, CITY OF NEWPORT BEACH, COUNTY OF ORANGE,
STATE OF CALIFORNIA
M.M. 28/25-36
COASTAL CALCULATIONS:
2,204 S.F. X 2 = 4,408 S.F. ALLOWABLE
(3,676 S.F. < 4,408 S.F.)
BUILDING AREA SCHEDULE
LEVEL AREA COMMENTS
FIRST FLOOR 1345 SF
SECOND FLOOR 1823 SF
3168 SF
GARAGE 508 SF
508 SF
GRAND TOTAL 3676 SF
LANDSCAPE AREA SCHEDULE
NAME AREA COMMENTS
PLANTED 115 SF
Grand total 115 SF
TOTAL LIVING
TOTAL GARAGE
GRAND TOTAL
GRAND TOTAL ≤500 S.F.
ROOF AREA SCHEDULE
NAME AREA COMMENTS
SLOPED ROOFS 1700 SF
FLAT ROOF 452 SF 2,152 S.F.X 0.25 = 538 S.F. MAX FLAT
2,152 S.F.X 0.25 = 538 S.F. MAX FLAT
Grand total 2152 SF
A SITE INFORMATION
GRAND TOTAL
2,152 S.F.X 0.25 = 538 S.F. MAX FLAT
B PROJECT STATISTICS
1/8" = 1'-0"5 1ST FLOOR HOA OPEN AREA @ FRONT
1/8" = 1'-0"6 2ND FLOOR HOA OPEN AREA @ FRONT
NO. REVISION DATE
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
BRANDON ARCHITECTS
11.30.22
3-DIMENSIONAL
VIEWS
AN
T
E
P
A
R
A
R
E
S
I
D
E
N
C
E
PAUL ANTEPARA
604 VIA LIDO NORD
NEWPORT BEACH, CA 92663
HOA SUBMITTAL
604 VIA LIDO NORD
NEWPORT BEACH, CA 92663
A-1.0
TBD
KENNEDY YEAR
1 AXONOMETRIC NORTHEAST
2 AXONOMETRIC SOUTHEAST 3 AXONOMETRIC SOUTHWEST
4 AXONOMETRIC NORTHWEST
NO. REVISION DATE
UP
A-4.02
A-4.0
A-4.0
A-4.0
4
3
1
1
A-5.0
1
A-5.0
DINING
GREAT ROOM
KITCHEN
FOYER
BEDROOM #1
POWDER
PANTRY
STAIRS
BATH #1
2-CAR GARAGE
S.Y.S.B.
3'
-
0
"
S.Y
.
S
.
B
.
3'
-
0
"
F.Y.S.B.
10' - 0"
F.Y.S.B.
4' - 0"
2
A-5.0
2
A-5.0
2
34
4
12
9
10
11
5
1 2
8
UP
UP
12
3
3
2
1
1
1
4
4
5
6
7
8
R @ 0' -6 5/8"3
R @ 0' -7 1/4"16
9
10
11
12
13
14
14
8
15
1617
18
19
12
20
20
17
17
26
27
5
31
HALLWAY
23
WINE CLOSET
CL
O
S
E
T
TYP.
11
"
CLR.
3' - 11 1/2"
CLR.
3' - 11 1/2"
CLR.
3'
-
1
1
1
/
2
"
CLR.
8' - 0"
CLR.
20' - 9 3/8"
CLR.
22
'
-
5
1
/
4
"
28
29
30
CLR.
21' - 7 3/8"
3
B
C
6
7
A
1
6.1
2
A-5.1
2
A-5.1
1
A-5.1
1
A-5.1
2
A-5.2
2
A-5.2
1
A-5.2
1
A-5.2
1
A-5.3
1
A-5.3
2
A-5.3
2
A-5.3
31
A-4.02
A-4.0
A-4.0
A-4.0
4
3
1
MASTER SUITE
MASTER BATH
LAUNDRY
MASTER W.I.C.
BEDROOM #3
BATH #2
BEDROOM #2
1
A-5.0
1
A-5.0
2
A-5.0
2
A-5.0
UP
BATH #3W/C.
STAIRS
W/C.
15
13
11 10
9
8
22
21
16
15
17
19
20
23
161514
8
12
21
17
22
23
24
2012
21
25
12 13
6
5
2
3
28
29
30
30
31
29
14
14
14
14
BEV.
18
COFFEE
STATION
4
WET ROOM
14
17
17
HALL LINEN
CLR.
3' - 11 1/2"
TYP.
11
"
CLR.
3'
-
1
1
1
/
2
"
CLR.
8' - 0"
TY
P
.
11
"
CLR.
3' - 0"
CL
R
.
3'
-
0
"
CL
R
.
3'
-
0
"
CLR.
3' - 3 1/8"
CLR.
3' - 3 1/8"
CLR.
3' - 0"
32
CLR.
3' - 11 1/2"
3' - 1"
9
7
14
HALLWAY
14.1
16.1 21.1
2
A-5.1
2
A-5.1
1
A-5.1
1
A-5.1
2
A-5.2
2
A-5.2
1
A-5.2
1
A-5.2
1
A-5.3
1
A-5.3
2
A-5.3
2
A-5.3
31
33
2% MIN. SLOPE
ROOM TAGROOM NAME
1
A-5.0
1 1
?
1
1
A-4.0
1
1 1
1
ELEVATION / SECTION INDICATOR
AD-1.0
1 CALL-OUT TAG
10.00'SPOT ELEVATION
KEYNOTE TAG
REVISION TAG
DOOR / WINDOW / WINDOW WALL TAG
FIRE RATED CEILING ASS'Y -REF. DTLS. 8/AD-1.0
1-HR RATED INT CONDITION -REF. DTLS. 8/AD-1.0
1-HR RATED EXT CONDITION -REF. DTLS. 12/AD-1.0
STRUCTURAL STEEL COLUMN PER STRUCT., REF. STRUTC.
DWGS, -PAINT AND SEAL AS REQUIRED –ARCH. TO APPV.
COLOR FOR EXPOSED STEEL COLUMNS
STRUCTURAL WOOD POST/COLUMN COLUMN -PER STRUCT., REF. STRUTC. DWGS, -
PAINT, STAIN AND SEAL AS REQUIRED –ARCH. TO APPV. PAINT COLOR FOR EXPOSED
WOOD POST/COLUMN, IF TO BE STAINED PROVIDE STAINED SAMPLE FOR ARCH,
APPROVAL
DOORS -AS SPECIFIED, SEE WINDOW SCHEDULE AND GENERAL NOTES ON SHEET A-7.0 -
SHGC & U-FCTOR PER T-24 ENERGY REPORT – SEE SHEET AD-2.0 FOR JAMB, HEAD AND
THRESHOLD DETAILS, PROVIDE FLASHING AND WATERPROOFING AT DOOR OPENING PER
THE DOOR MFGR. INSTRUCTION AND/OR FLASHING MFGR. INSTRUCTION PER SECTIONS
R609.1 & R703.4 OF CRC
WINDOW -AS SPECIFIED, SEE WINDOW SCHEDULE AND GENERAL NOTES ON
SHEET A-7.0 -SHGC & U-FCTOR PER T-24 ENERGY REPORT – SEE SHEET
AD-2.0 FOR JAMB, HEAD AND SILL DETAILS, PROVIDE FLASHING AND
WATERPROOFING AT WINDOW OPENING PER THE WINDOW MFGR.
INSTRUCTION AND/OR FLASHING MFGR. INSTRUCTION PER SECTIONS R609.1
& R703.4 OF CRC
KITCHEN RANGE W/. EXHAUST HOOD -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –
PROVIDE POWER AND GAS AS REQUIRED -30”MIN. VERTICAL CLEARANCE TO ANY
COMBUSTIBLE MATERIAL ABV. COOKING TOP (CMC 920.3.2) –EXHAUST HOOD TO HAVE
EXHAUST RATE OF MIN. 100 CFM AND VENT TO OUTDOOR , HOOD DUCTS TO BE OF
METAL WITH SMOOTH INTERIOR FINISH PER SECTION 504.3 OF CMC
KITCHEN/BAR SINK -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –SINK TO COMPLY
W/. REQUIREMENT OF SECTION 420.0 OF CPC AND HAVE A MAX FLOW RATE OF 1.8 GPM
@ 60 PSI PER SECTION 4.303.1 OF CALGREEN –TRAP AND VENT FOR ISLAND SINK AND
SIMILAR EQUIPMENT SHALL BE PER SECTION 909.0 OF CPC
VANITY SINK -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –
LAVATORY TO HAVE 24”MIN. CLEAR SPACE IN FRONT OF IT.(CPC 402.5)
W/. MAXIMUM FLOW RATE OF 1.2 GPM @ 60 PSI AND MIN. FLOW RATE OF
0.8 GPM @ 20 PSI PER SECTION 4.303.1 OF CALGREEN
WASHER (W) / DRYER (D) / STACKED (W/D)-AS SELECTED PER I.D., VERIFY W/. I.D. &
OWNER –PROVIDE POWER , GAS, WATER SUPPLY & DRAINAGE AS REQUIRED -THE
CLOTHES DRYERS VENT SHALL BE OF A RIGID METALLIC MATERIAL AND HAVE A
BACKDRAFT DAMPER (CMC 504.4) AND SHALL NOT EXCEED 14-FEET IN OVERALL LENGTH
WITH MAX. OF TWO (2) 90-DEGREE ELBOW, SUBTRACT 2-FEET FOR EACH ADDITIONAL 90-
DEGREE ELBOW. SEE WASHER & DRYER NOTES, REF. T-1.1.
REFRIGERATOR (REF) / FREEZER (FRZ) -AS SELECTED PER I.D., VERIFY W/. I.D. &
OWNER –PROVIDE POWER AND WATER SUPPLY AS REQUIRED
BUILT-IN APPLIANCE / DISHWASHER (DW) / TRASH COMPACTOR (TR)-AS SELECTED PER
I.D., VERIFY W/. I.D. & OWNER –PROVIDE POWER , WATER SUPPLY & DRAINAGE PIPE AS
REQUIRED
TOILET -WATER CLOSET SHALL BE IN COMPLIANCE OF SECTION 411.0 OF CPC AND HAS
MAX EFFECTIVE FLUSH RATE OF 1.28 GAL. PER FLUSH (CPC 411.2). WATER CLOSETS
CLR. TO BE 24”IN FRONT AND 15”FROM ITS CENTER TO ANY SIDE WALL OR
OBSTRUCTION. (CPC 402.5 & CRC R307) –REF. CALGREEN NOTES ON T SHTS. FOR MAX
FLOW RATE
CASEWORK, TALL CABINET -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER
CASEWORK, BASE CABINET W/. COUNTERTOP -AS SELECTED PER I.D., VERIFY W/. I.D. &
OWNER
CASEWORK, UPPER CABINET/SHELVES -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER
BUILT-IN CLOSET -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER
FIREPLACE -FACTORY-BUILT DIRECT VENT GAS FIREPLACE W/. SEALED COMBUSTION
(CALGREEN 4.503) -FACTORY-BUILT FIREPLACES, CHIMNEYS AND ALL OF THEIR
COMPONENTS SHALL BE LISTED AND INSTALLED IN ACCORDANCE WITH THEIR LISTING
AND MANUFACTURER'S INSTALLATION INSTRUCTIONS. (CRC R1004.1)
ELEVATOR -PRIVATE RESIDENCE ELEVATOR IN COMPLIANCE W/. ASME A17.1/CSA B44
AS SELECTED PER PLANS, VERIFY W/. OWNER –PROVIDE POWER AS REQ'D. (CRC 321.1)
A/C CONDENSER / HEAT PUMP -TO BE IN COMPLIANCE OF SECTION 307.3 OF CMC AS
SELECTED, VERIFY W/. OWNER -SIZE TBD, SEE T-24 ENERGY REPORT FOR MORE INFO –
PROVIDE POWER AND SOUND DAMPENING PAD AS REQ’D. –INSTALL AND MAINTAIN
REQUIRED CLEARANCES PER MFGR. INSTRUCTION
FAU -PROVIDE GAS S.O., POWER, AND VENTING AS REQ'D. BY MFG'R. –INSTALL PER
MFGR. INSTRUCTION
ROOF/DECK DRAIN -PER CHAPTER 11 OF CPC -SIZE THE DRAIN AND PIPING PER TABLE
1103.1 AND 1103.2 OF CPC –ROOF DRAIN SHALL HAVE DOMED STRAINER (CPC 1102.2) –
REF. DETAIL 11/AD-1.0
OVERFLOW OR EMERGENCY DRAIN -PER CHAPTER 11 OF CPC -COPPER OR EQ., INSTALL
PER MFGR. INSTRUC., SLOPED TOWARD IN-WALL DRAIN INLETS –SLOPE AND SIZE PER
TABLE 1103.3 OF CPC –REF. DTL. 11/AD-1.0
UP
20R@7 1/2"STAIRS -MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE AN ILLUMINATION LEVEL OF NOT
LESS THAN 1 FOOT CANDLE AS MEASURED AT THE CENTER OF TREADS AND
LANDING WITH ARTIFICIAL LIGHTING (R303.7) -REF. DTL. 3/AD-1
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
KEYNOTESB
ANNOTATION LEGENDA
BRANDON ARCHITECTS
11.30.22
FLOOR PLANS
AN
T
E
P
A
R
A
R
E
S
I
D
E
N
C
E
PAUL ANTEPARA
604 VIA LIDO NORD
NEWPORT BEACH, CA 92663
HOA SUBMITTAL
604 VIA LIDO NORD
NEWPORT BEACH, CA 92663
A-2.0
TBD
KENNEDY YEAR
1/4" = 1'-0"2 FIRST FLOOR PLAN
1/4" = 1'-0"1 SECOND FLOOR PLAN
NO. REVISION DATE
1 PROPERTY LINE - REF. SURVEY
2 FRONT YARD SETBACK
3 SIDE YARD SETBACK
4 WATER HEATER - TANK-LESS (ON DEMAND) WALL-MOUNT +48" MIN., 'TAKAGI' OR EQUIV. - SIZE AND INSTALL PER
CHAPTER 5 OF CPC AND MFGR. INSTRUCTION, VERIFY THE SIZING W/. ENERGY REPORT (PROVIDE ADEQUATE N.G.
CONN. & POWER AS REQ'D.)
5 RECESSED MAIN SERVICE PANEL, 400 AMP MAX. (MAINTAIN 36" CLEAR FROM FACE OF PANEL TO ANY OBSTRUCTION)
6 GARAGE DOOR - CUSTOM BUILT, REF. MAT. AND DOOR SCHED., SHEETS A-4.0 & A-7.0- ARCH TO APPV. SHOP DWGS.
PRIOR TO FAB.
7 GARAGE DOOR - RATED, 1-3/8" SOLID CORE, SELF-CLOSING AND SELF-LATCHING. REF. DOOR SCHEDULE, SHEET A-7.0
(CRC R302.5.1)
8 STAIRS - MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE AN ILLUMINATION LEVEL OF NOT LESS THAN 1 FOOT CANDLE AS
MEASURED AT THE CENTER OF TREADS AND LANDING WITH ARTIFICIAL LIGHTING (R303.7) - REF. DTL. 1/AD-1.0
9 RANGE AS SELECTED PER I.D., VERIFY APPLIANCE W/. I.D. & OWNER - PROVIDE POWER, GAS AND HOOD CAPABLE OF
100 CFM MIN. (VERIFY W/. MFG.) - VENT TO OUTDOOR AIR
10 REFRIGERATOR AS SELECTED PER I.D., PROVIDE POWER - VERIFY W/. I.D. AND OWNER
11 FREEZER AS SELECTED PER I.D., PROVIDE POWER - VERIFY APPLIANCE W/. I.D. & OWNER
12 TOILET - MIN. CLR. TO BE 24” IN FRONT AND 15” FROM ITS CENTER TO ANY SIDE WALL OR OBSTRUCTION - SEE
PLUMBING NOTES ON B/T-1.1 FOR MORE INFO AND REQ'S.
13 KITCHEN ISLAND - BASE CABINET, COUNTER, AND APPLIANCES PER I.D - VERIFY SIZE & FINISH W/. I.D. & OWNER
14 FURNISHINGS AS SELECTED PER I.D.- VERIFY APPLIANCE W/. I.D. & OWNER
15 EGRESS LADDER - TO BE PERMANENTLY AFFIXED AND NOT OBSTRUCT THE EMERGENCY ESCPAE OPENING. INSIDE
WIDTH OF 12" MIN., PROJECT 3" MIN. FROM THE WALL, AND SHALL NOT BE SPACED MORE THAN 18" ON CENTER. REF.
R310.2.
16 UPPER CABINET PER I.D. - FINISH AS SELECTED, VERIFY W/. I.D. AND OWNER
17 BASE CABINET PER I.D. - FINISH AS SELECTED, VERIFY W/. I.D. AND OWNER
18 1-1/2" MAX. STEP AT OUT SWING REQ'D. EGRESS DOORS (R311.3.1)
19 LINE OF SECOND FLOOR ABOVE
20 VANITY AS SELECTED IN COMPLIANCE W/. SECTION 407 OF CPC PER I.D., MIN. 24" CLR. SPACE IN FRONT- SINK, BASE
CABINET AND COUNTER PER I.D. - FINISH AS SELECTED, VERIFY SIZE AND FINISH W/. I.D. AND OWNER
21 BUILT-IN CLOSET PER I.D. - FINISH AS SELECTED, VERIFY W/. I.D. AND OWNER
22 FIREPLACE - FLARE PREFABRICATED FIREPLACE LISTED TO ANSI Z21.88/CSA 2.33-2014, GAS ONLY,DIRECT VENT W/.
SEALED COMBUSTION - specify model, configuration & size here [DTL. 24/AD-1] (FACTORY BUILT FIREPLACES,
CHIMNEYS, AND ALL OF THEIR COMPONENTS SHALL BE LISTED AND INSTALLED IN ACCORDANCE W/. THEIR LISTING
AND MFG'R. INSTALLATION INSTRUCTIONS. GASEOUS FUEL BURNING PAN MUST BE PERMANENTLY ANCHORED TO
THE FIREBOX. FIREPLACE MUST COMPLY W/. THE CALIFORNIA ENERGY STANDARDS MANDATORY MEASURES.) - REF.
FIREPLACE NOTES ON B/T-1.1 FOR MORE INFO
23 TALL CABINET PER I.D. - FINISH AS SELECTED, VERIFY W/. I.D. AND OWNER
24 BATHTUB - FREE-STANDING, AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER (VERIFY LOC'N. OF FIXTURES W/. OWNER)
- SEE PLUMBING NOTES ON B/T-1.1 FOR MORE INFO AND REQ'S.
25 EXTERIOR GLASS GUARDRAIL , TEMPERED & LAMINATED - MIN. 42" HIGH ABV.F.F. - <4" MAX. SPHERE OPENING, REF.
DTL. 4/AD-1.0
26 KITCHEN SINK IN COMPLIANCE W/. CPC SECTION 420 - BASE CABINET AND COUNTER CONFIGURATION PER I.D. - FINISH
AS SELECTED, VERIFY W/. I.D. AND OWNER
27 FIREPLACE - ISOKERN BVETTO MODULAR REFRACTORY PRECAST FIREPLACE, GAS ONLY, DIRECT VENT W/. SEALED
COMBUSTION PER ICC ESR-4873 [REF. DTL. 24/AD-1] (FACTORY BUILT FIREPLACES, CHIMNEYS AND ALL OF THEIR
COMPONENTS SHALL BE LISTED AND INSTALLED IN ACCORDANCE W/. THEIR LISTING AND MFG'R. INSTALLATION
INSTRUCTIONS. GASEOUS FUEL BURNING PAN MUST BE PERMANENTLY ANCHORED TO THE FIREBOX. FIREPLACE MUST
COMPLY W/. THE CALIFORNIA ENERGY STANDARDS MANDATORY MEASURES.) - REF. FIREPLACE NOTES ON B/T-1.1 FOR
MORE INFO
28 BATHTUB & SHOWER - PROVIDE TILE W/. CEMENT BACKING MIN. 72" HIGH (R307.2) - SEE PLUMBING NOTES ON B/T-1.1
FOR MORE INFO AND REQ'S.
29 CUSTOM SHOWER SEAT PER I.D., VERIFY W/. I.D. & OWNER
30 DEPRESS STRUCTURE FOR FLUSH SHOWER CONDITION - VERIFY WITH I.D. - REF. STRUCT. DWGS.
31 TELEVISION AS SELECTED BY OWNER- VERIFY APPLIANCE W/. I.D. & OWNER
32 INTERIOR GLASS GUARDRAIL - MIN. 42" HIGH ABV.F.F. - MATERIAL AS SELECTED, <4" MAX. SPHERE OPENING, REF.
DTL. 4/AD-1.0
33 SHOWER - PROVIDE TILE W/. CEMENT BACKING MIN. 72" HIGH (R307.2) - SEE PLUMBING NOTES ON B/T-1.1 FOR MORE
INFO AND REQ'S.
UP
DIMENSION NOTE:
ALL DIMENSIONS ARE TO FACE OF SHEATHING (EXT. WALLS) OR FACE OF STRUCTURE (F.O.S.) TYP. U.N.O. ROUNDED TO THE
NEAREST 1/8" AND INTERIOR PARTITIONS ARE DIMENSIONED FROM FACE OF STRUCTURE TO FACE OF STRUCTURE (F.O.S.) U.N.O. -
CONTACT ARCHITECT IN WRITING FOR ANY CLARIFICATION OF NOTED DIMENSIONS, DO NOT SCALE PLANS.
ROUGH FRAMING:
ALL EXTERIOR WALLS TO BE FRAMED W/. 2X6 STUD MIN. U.N.O.
USE 2X6 MINIMUM STUDS FOR PLUMBING WALLS
SECOND AND THIRD FLOOR PLYWOOD TO BE 1-1/8"
ENTIRE EXTERIOR TO BE SHEATHED WITH 1/2" PLYWOOD
DOORS AND WINDOWS WILL TYPICALLY BE RECESSED FROM EXTERIOR WALL PLANE. VERIFY ALL ROUGH OPENING DIMENSIONS
WITH DOOR AND WINDOW MFGR. ROUGH OPENING MAY NEED TO BE OVERSIZED TO ACCOUNT FOR ADDITIONAL FRAMING. SEE
SHT. AD-2.0 FOR TYP. RECESSED CONDITIONS.
GARAGE FLOOR:
GARAGE FLOOR SURFACES SHALL BE OF APPROVED NONCOMBUSTIBLE MATERIAL.THE AREA OF FLOOR USED FOR PARKING OF
AUTOMOBILES OR OTHER VEHICLES SHALL BE SLOPED TO FACILITATE THE MOVEMENT OF LIQUIDS TO A DRAIN OR TOWARD THE
MAIN VEHICLE ENTRY DOORWAY. (R309.1)
PLUMBING:
1. SUPPORT ALL WALL-HUNG FIXTURES WITH METAL SUPPORTING MEMBERS TO PREVENT ANY STRAIN TRANSMISSION TO THE
CONNECTIONS. FRAMING AFFIXED SUPPORTS FOR OFF-THE-FLOOR WATER CLOSETS WITH CONCEALED TANKS SHALL COMPLY
WITH ASME A112.6.2. SECURE FLUSH TANK AND SIMILAR APPURTENANCES WITH APPROVED NON-CORROSIVE SCREW OR BOLTS.
(CPC 402.5)
2. THE NET AREA OF THE SHOWER ENCLOSURE SHALL BE 1,024 SQ. INCHES (7.1 SQ. FT.) OR MORE IN THE CLEAR FLOOR AREA,
AND SHALL ALSO BE CAPABLE OF ENCOMPASSING A 30-INCH DIAMETER CIRCLE. (CPC 408.6)
3. THE WATER HEATER BURNER AND BURNER-IGNITION DEVICE TO BE AT LEAST 18-INCHES ABOVE THE FLOOR, IF LOCATED IN A
GARAGE AND IN ADJACENT SPACES THAT OPEN TO THE GARAGE. FOR WATER HEATER IN THE GARAGE OR OTHER AREAS SUBJECT
TO MECHANICAL DAMAGE PROVIDE A PROTECTIVE BARRIER OR ELEVATE THE APPLIANCE TO BE OUT OF THE NORMAL PATH OF
THE VEHICLE. (CPC 507.13)
4. ANCHOR OR STRAP THE WATER HEATER(S) TO RESIST HORIZ. DISPLACEMENT DUE TO THE EARTHQUAKE. STRAPPING SHOULD
BE AT THE UPPER AND LOWER ONE THIRD (1/3) POINTS OF THE APPLIANCE HEIGHT. MAINTAIN A MIN. 4-INCHES ABOVE THE
CONTROLS WITH STRAPPING AT LOWER POINT.
WOOD OR WOODBASED PRODUCTS NOTE:
WOOD OR WOODBASE PRODUCT SHALL BE OF A NATURAL DURABLE OR PRESERVATIVE-TREADED WOOD IN ACCORDANCE WITH
AWPA U1 FOR THE SPECIES, PRODUCT, PRESERVATIVE AND END USE IN THE FOLLOWING LOCATIONS:
1. WOOD JOISTS OR THE BOTTOM OF A WOOD STRUCTURAL FLOOR WHEN CLOSER THAN 18 INCHES (457 MM) OR WOOD GIRDERS
WHEN CLOSER THAN 12 INCHES (305 MM) TO THE EXPOSED GROUND IN CRAWL SPACES OR UNEXCAVATED AREA LOCATED
WITHIN THE PERIPHERY OF THE BUILDING FOUNDATION.
2. WOOD FRAMING MEMBERS THAT REST ON CONCRETE OR MASONRY EXTERIOR FOUNDATION WALLS AND ARE LESS THAN 8
INCHES (203 MM) FROM THE EXPOSED GROUND.
3. SILLS AND SLEEPERS ON A CONCRETE OR MASONRY SLAB THAT IS IN DIRECT CONTACT WITH THE GROUND UNLESS
SEPARATED FROM SUCH SLAB BY AN IMPERVIOUS MOISTURE BARRIER.
4. THE ENDS OF WOOD GIRDERS ENTERING EXTERIOR MASONRY OR CONCRETE WALLS HAVING CLEARANCES OF LESS THAN 1/2
INCH (12.7 MM) ON TOPS, SIDES AND ENDS.
5. WOOD SIDING, SHEATHING AND WALL FRAMING ON THE EXTERIOR OF A BUILDING HAVING A CLEARANCE OF LESS THAN 6
INCHES (152 MM) FROM THE GROUND OR LESS THAN 2 INCHES (51 MM) MEASURED VERTICALLY FROM CONCRETE STEPS,
PORCH SLABS, PATIO SLABS AND SIMILAR HORIZONTAL SURFACES EXPOSED TO THE WEATHER.
6. WOOD STRUCTURAL MEMBERS SUPPORTING MOISTURE-PERMEABLE FLOORS OR ROOFS THAT ARE EXPOSED TO THE
WEATHER, SUCH AS CONCRETE OR MASONRY SLABS, UNLESS SEPARATED FROM SUCH FLOORS OR ROOFS BY AN IMPERVIOUS
MOISTURE BARRIER.
7. WOOD FURRING STRIPS OR OTHER WOOD FRAMING MEMBERS ATTACHED DIRECTLY TO THE INTERIOR OF EXTERIOR MASONRY
WALLS OR CONCRETE WALLS BELOW GRADE EXCEPT WHERE AN APPROVED VAPOR RETARDER IS APPLIED BETWEEN THE WALL
AND THE FURRING STRIPS OR FRAMING MEMBERS.
*HERS VERIFICATION REQUIRED-REFERENCE T-24.1
ROOM TAGROOM NAME
1
1
1
1
10.00'SPOT ELEVATION
REVISION TAG
DOOR TAG
WINDOW WALL TAG
WINDOW TAG
STRUCTURAL STEEL COLUMN PER STRUCT., REF. STRUTC.
DWGS, -PAINT AND SEAL AS REQUIRED –ARCH. TO APPV.
COLOR FOR EXPOSED STEEL COLUMNS
STRUCTURAL WOOD POST/COLUMN COLUMN -PER STRUCT., REF. STRUTC. DWGS, -
PAINT, STAIN AND SEAL AS REQUIRED –ARCH. TO APPV. PAINT COLOR FOR EXPOSED
WOOD POST/COLUMN, IF TO BE STAINED PROVIDE STAINED SAMPLE FOR ARCH,
APPROVAL
KITCHEN RANGE W/. EXHAUST HOOD -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –
PROVIDE POWER AND GAS AS REQUIRED -30”MIN. VERTICAL CLEARANCE TO ANY
COMBUSTIBLE MATERIAL ABV. COOKING TOP (CMC 920.3.2) –EXHAUST HOOD TO HAVE
EXHAUST RATE OF MIN. 100 CFM AND VENT TO OUTDOOR , HOOD DUCTS TO BE OF
METAL WITH SMOOTH INTERIOR FINISH PER SECTION 504.3 OF CMC
KITCHEN/BAR SINK -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –SINK TO COMPLY
W/. REQUIREMENT OF SECTION 420.0 OF CPC AND HAVE A MAX FLOW RATE OF 1.8 GPM
@ 60 PSI PER SECTION 4.303.1 OF CALGREEN –TRAP AND VENT FOR ISLAND SINK AND
SIMILAR EQUIPMENT SHALL BE PER SECTION 909.0 OF CPC
VANITY SINK -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –
LAVATORY TO HAVE 24”MIN. CLEAR SPACE IN FRONT OF IT.(CPC 402.5)
W/. MAXIMUM FLOW RATE OF 1.2 GPM @ 60 PSI AND MIN. FLOW RATE OF
0.8 GPM @ 20 PSI PER SECTION 4.303.1 OF CALGREEN
WASHER (W) / DRYER (D) / STACKED (W/D)-AS SELECTED PER I.D., VERIFY W/. I.D. &
OWNER –PROVIDE POWER , GAS, WATER SUPPLY & DRAINAGE AS REQUIRED -THE
CLOTHES DRYERS VENT SHALL BE OF A RIGID METALLIC MATERIAL AND HAVE A
BACKDRAFT DAMPER (CMC 504.4) AND SHALL NOT EXCEED 14-FEET IN OVERALL LENGTH
WITH MAX. OF TWO (2) 90-DEGREE ELBOW, SUBTRACT 2-FEET FOR EACH ADDITIONAL 90-
DEGREE ELBOW. SEE WASHER & DRYER NOTES, REF. T-1.1.
TOILET -WATER CLOSET SHALL BE IN COMPLIANCE OF SECTION 411.0 OF CPC AND HAS
MAX EFFECTIVE FLUSH RATE OF 1.28 GAL. PER FLUSH (CPC 411.2). WATER CLOSETS
CLR. TO BE 24”IN FRONT AND 15”FROM ITS CENTER TO ANY SIDE WALL OR
OBSTRUCTION. (CPC 402.5 & CRC R307) –REF. CALGREEN NOTES ON T SHTS. FOR MAX
FLOW RATE
FIREPLACE -FACTORY-BUILT DIRECT VENT GAS FIREPLACE W/. SEALED COMBUSTION
(CALGREEN 4.503) -FACTORY-BUILT FIREPLACES, CHIMNEYS AND ALL OF THEIR
COMPONENTS SHALL BE LISTED AND INSTALLED IN ACCORDANCE WITH THEIR LISTING
AND MANUFACTURER'S INSTALLATION INSTRUCTIONS. (CRC R1004.1)
A/C CONDENSER / HEAT PUMP -TO BE IN COMPLIANCE OF SECTION 307.3 OF CPC AS
SELECTED, VERIFY W/. OWNER -SIZE TBD, SEE T-24 ENERGY REPORT FOR MORE INFO –
PROVIDE POWER AND SOUND DAMPENING PAD AS REQ’D. –INSTALL AND MAINTAIN
REQUIRED CLEARANCES PER MFGR. INSTRUCTION
FAU -PROVIDE GAS S.O., POWER, AND VENTING AS REQ'D. BY MFG'R. –INSTALL PER
MFGR. INSTRUCTION
RECESSED MAIN SERVICE PANEL -400 AMP MAX. (MAINTAIN 36" CLEAR FROM FACE
OF PANEL TO ANY OBSTRUCTION) –GC TO COORDINATE W/. UTILITY COMPANY
ROOF/DECK DRAIN -PER CHAPTER 11 OF CPC -SIZE THE DRAIN AND PIPING PER TABLE
1103.1 AND 1103.2 OF CPC –ROOF DRAIN SHALL HAVE DOMED STRAINER (CPC 1102.2) –
REF. DETAIL 11/AD-1.0
OVERFLOW OR EMERGENCY DRAIN -PER CHAPTER 11 OF CPC -COPPER OR EQ., INSTALL
PER MFGR. INSTRUC., SLOPED TOWARD IN-WALL DRAIN INLETS –SLOPE AND SIZE PER
TABLE 1103.3 OF CPC –REF. DTL. 11/AD-1.0
2X4 STUD WALL
2X6 STUD WALL
2X8 STUD WALL
2X10 STUD WALL
EXT. POCKET DOOR WALL - TYP. 2X6 EXT. FRMG. AND 2X4 INTERIOR FRAMING W/.
DOUBLE TOP PLATE AND SINGLE SILL PLATE U.N.O., MIN. AIR SPACE/DOOR POCKET
TO BE VERIFIED W/. DOOR MFGR. - STUDS MIN. SPACING PER STRUCT. AND EXT.
FINISH MFGR. INSTRUCTION AND/OR LISTING –SEE EXT. WALL DETAILS AND STRUCT.
DWGS
CONCRETE WALL -12”REINFORCED CAST IN PLACE CONCRETE WALL TYP. U.N.O. PER
STRUCT., REF. STRCUTC. DWGS. –FOR BASEMENT/RETAINING CONCRETE WALL
PROVIDE WATERPROOFING OR DAMPPROOFING AND DRAINAGE AS REQUIRED PER
SECTION R406.1 & R406.2, REF. SOILS REPORT,WATERPROOFING & DAMPROOFING
NOTES ON SHEET T-1.1 –EXPOSED SURFACES TO HAVE TROWELED SMOOTH FINISH
WITH A LIGHT GRAY COLOR, PROVIDE SAMPLE FOR ARCH. APPROVAL
SLAB/FRAMING DEPRESSION -SEE STRUCT. DWGS. FOR THE RECESSION DETAILS -
FOR RECESSION SPECIFIC TO EQUIPMENT OR ASSEMBLY VERIFY THE REQUIRED
RECESSION W/. MFGR. OR FABRICATOR –SHOWER RECESSION TO BE VERIFIED W/.
I.D.
SEE SHEET AD-2.0 FOR THE TYPICAL DEPRESSION OF DOORS AND WINDOWS, VERIFY
ALL DEPRESSIONS W/. MFGR.
STUDS MIN. SPACING PER STRUCT. AND EXT. FINISH MFGR.
INSTRUCTION AND/OR LISTING –SEE EXT. WALL DETAILS AND
STRUCT. DWGS
VERTICAL STORM DRAIN PIPE IN-WALL / OVERFLOW -MTL. PIPE PER
CHAPTER 11 OF CPC, SIZE PER TABLE 1103.1 (MIN. 2”DIA. PIPE & TYP. 3”DIA. PIPE) –
SEE CIVIL DWGS. FOR TERMINATION DTLS. ABV. OR BLW. GROUND. VERIFY ALL
TERMINATION POINTS, TYPE AND DETAILS W/. CIVIL PRIOR TO POURING THE CONCRETE
SLAB
OVERFLOW
DRAINLINE
A-4.02
A-4.0
A-4.0
A-4.0
4
3
1
1
A-5.0
1
A-5.0
2
A-5.0
2
A-5.0
DINING
GREAT ROOM
KITCHEN
FOYERBEDROOM #1
POWDER
PANTRY
STAIRS
BATH #1
2-CAR GARAGE
3'
-
1
"
28
'
-
1
0
"
3'
-
1
"
2'
-
7
7
/
8
"
25
'
-
6
"
8 1
/
8
"
4' - 2"70' - 9"15' - 1"
21' - 7 1/2"18' - 8"6' - 2"8' - 0 3/8"6' - 8"9' - 7 1/8"
5' - 3 5/8"3' - 0"
4"
11 3/8"6' - 0 3/4"2' - 3 5/8"7' - 6"2' - 9 5/8"6' - 2"
4' - 2"70' - 9"15' - 1"
18' - 5 3/8"4' - 6 5/8"4' - 0 1/8"4' - 0 1/8"5' - 3 5/8"2' - 8 5/8"4' - 4 1/8"7' - 11 7/8"17' - 5 7/8"1' - 10 1/2"
8'
-
2
"
23
'
-
8
"
3'
-
2
"
3'
-
1
"
17
'
-
6
"
3'
-
1
"
2'
-
8
3
/
8
"
2'
-
8
1
/
4
"
4'
-
1
"
4'
-
6
"
7'
-
0
5
/
8
"
4'
-
7
3
/
8
"
4'
-
3
1
/
8
"
4'
-
1
"
4'
-
1
"
2'
-
6
1
/
8
"
11
'
-
1
1
/
2
"
3'
-
2
"
11
"
UP
UP
R @ 0' -6 5/8"3
R @ 0' -7 1/4"16
23' - 0"8' - 0 1/4"8' - 0 1/4"31' - 8 1/2"
4 1
/
2
"
21' - 8"10"5' - 0 1/8"5' - 3 3/4"4' - 3 1/8"2' - 3"
HALLWAY
WINE CLOSET
CLR.
11
'
-
0
"
CLR.
12' - 0"
TYP.
11
"
CLR.
3' - 11 1/2"
CLR.
3' - 11 1/2"
CLR.
3'
-
1
1
1
/
2
"
CLR.
8' - 0"
CLR.
20' - 9 3/8"
CLR.
22
'
-
5
1
/
4
"
5'
-
2
"
9'
-
4
"
13
'
-
1
"
11
'
-
2
1
/
4
"
11
'
-
4
"
11
'
-
6
1
/
8
"
11
'
-
7
"
10' - 10 7/8"10' - 10 7/8"
2'
-
6
3
/
8
"
11
'
-
1
5
/
8
"
11
'
-
3
3
/
8
"
7'
-
4
7
/
8
"
2
A-5.1
2
A-5.1
1
A-5.1
1
A-5.1
2
A-5.2
2
A-5.2
1
A-5.2
1
A-5.2
1
A-5.3
1
A-5.3
2
A-5.3
2
A-5.3
A-4.02
A-4.0
A-4.0
A-4.0
4
3
1
1
A-5.0
1
A-5.0
2
A-5.0
2
A-5.0
MASTER SUITE
MASTER BATH
LAUNDRY
MASTER W.I.C.
BEDROOM #3
BATH #2
BEDROOM #2
BATH #3W/C.
STAIRS
W/C.
74' - 11"15' - 1"
4' - 0 3/4"18' - 11 1/4"1' - 1"5' - 10 1/4"1' - 1"9' - 6 3/4"7' - 10 3/8"6' - 4 5/8"1' - 3 5/8"12' - 6"1' - 3 5/8"
9 3/4"
5' - 0 1/2"
3'
-
1
"
28
'
-
1
0
"
3'
-
1
"
18
'
-
1
0
1
/
4
"
8'
-
8
1
/
4
"
1'
-
3
1
/
2
"
1'
-
3
1
/
4
"
17
'
-
6
"
1"
9' - 6 1/4"68' - 9 7/8"11' - 7 7/8"
31' - 7 1/8"9' - 6 1/8"8' - 0 3/8"6' - 8"9' - 7 1/8"3' - 5 1/8"
3' - 7 5/8"6' - 10 3/4"3' - 8 3/4"4' - 6 3/4"10' - 2 5/8"2' - 6 5/8"5' - 4 1/2"4' - 1 5/8"2' - 0 5/8"5' - 11 3/4"
1'
-
0
"
WET ROOM
TYP.
11
"
CLR.
3' - 11 1/2"
TYP.
11
"
CLR.
3'
-
1
1
1
/
2
"
CLR.
8' - 0"
TY
P
.
11
"
CLR.
3' - 0"
CL
R
.
3'
-
0
"
CL
R
.
3'
-
0
"
TYP.
11"
CLR.
3' - 3 1/8"
CLR.
3' - 3 1/8"
CLR.
3' - 0"
TY
P
.
11
"
CLR.
3' - 11 1/2"
8' - 6 1/4"1' - 0 7/8"
3' - 1"
3'
-
2
"
28
'
-
9
"
3'
-
1
"
2'
-
1
1
"
13
'
-
3
1
/
4
"
6'
-
1
1
/
8
"
1'
-
6
5
/
8
"
4'
-
1
1
"
2"
R.O.
9'
-
1
0
1
/
4
"
3'
-
3
"
15' - 6 3/4"2' - 10"8' - 6 5/8"1' - 10"4' - 2 7/8"3' - 0"2' - 0"
7 7/8"
5' - 3 1/8"6' - 4"15' - 0"
3' - 1"3' - 3"7' - 4 1/2"14' - 10 3/8"1' - 11"10' - 0 5/8"3' - 6 3/4"4' - 3 3/4"5' - 1 3/8"6' - 6 1/8"7' - 8 1/8"4'
-
0
3
/
8
"
2'
-
0
3
/
4
"
2'
-
0
"
2'
-
6
3
/
4
"
10
'
-
6
1
/
4
"
6'
-
5
5
/
8
"
6'
-
1
1
/
8
"
4'
-
6
3
/
4
"
10
'
-
1
3
/
4
"
9'
-
2
1
/
2
"
1'
-
1
1
3
/
8
"
2'
-
6
3
/
4
"
2'
-
0
"
6'
-
0
"
2'
-
1
3
/
4
"
3'
-
5
"
8'
-
7
3
/
4
"
1'
-
8
7
/
8
"
7
1
/
8
"
6'
-
1
3
/
4
"
11
'
-
1
7
/
8
"
HALLWAY
23' - 0"8' - 0 1/4"39' - 8 3/4"
2
A-5.1
2
A-5.1
1
A-5.1
1
A-5.1
2
A-5.2
2
A-5.2
1
A-5.2
1
A-5.2
1
A-5.3
1
A-5.3
2
A-5.3
2
A-5.3
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
BRANDON ARCHITECTS
ANNOTATION LEGEND
GENERAL NOTESA
B
11.30.22
DIMENSION PLANS
AN
T
E
P
A
R
A
R
E
S
I
D
E
N
C
E
PAUL ANTEPARA
604 VIA LIDO NORD
NEWPORT BEACH, CA 92663
HOA SUBMITTAL
604 VIA LIDO NORD
NEWPORT BEACH, CA 92663
A-2.1
TBD
KENNEDY YEAR
NO. REVISION DATE
1/4" = 1'-0"1 FIRST FLOOR DIMENSION PLAN
1/4" = 1'-0"2 SECOND FLOOR DIMENSION PLAN
UP
3'
-
1
"
5' - 1"
F.O.F.
9' - 0"
2'
-
0
"
1'
-
1
"
F.O.F.
2'
-
0
"
1'
-
1
"
F.O.F.
2'
-
0
"
1'
-
1
"
8' - 1 3/4"
1
1
1
2S.Y.S.B.
3'
-
0
"
F.Y.S.B.
4' - 0"
S.
Y
.
S
.
B
.
3'
-
0
"
F.Y.S.B.
10' - 0"
3
3
4
4
5
5
2' - 7 7/8"
F.O.F.
9' - 0"
6
6
66
7
3.
5
:
1
2
6.
5
:
1
2
6.5:12
6.
5
:
1
2
36.60' HT. CERT. REQ'D.
36.59'
35.58'
32.08'
ROOF DECK
14
'
-
6
"
14
'
-
6
"
5.
2
5
:
1
2
5.5:12
5.
2
5
:
1
2
6.5:12
5.5:12
5.
5
:
1
2
5.5:12
5.5:12
36.67' HT. CERT. REQ'D.
SPA
8
36.58'
1'
-
1
"
F.
O
.
F
.
2'
-
0
"
9
9
1' - 6"
8' - 10"
10
10
11
11
F.O.F.
7'
-
0
"
2'
-
5
5
/
8
"
3.5:12
3.
5
:
1
2
2
A-5.1
2
A-5.1
1
A-5.1
1
A-5.1
2
A-5.2
2
A-5.2
1
A-5.2
1
A-5.2
1
A-5.3
1
A-5.3
2
A-5.3
2
A-5.3
12
1
7'
-
1
0
5
/
8
"
7'
-
1
0
5
/
8
"
36.73' HT. CERT. REQ'D.36.73' HT. CERT. REQ'D.
36.73' HT. CERT. REQ'D.
36.41' HT. CERT. REQ'D.
DIMENSION NOTE:
ALL DIMS. ARE TO FACE OF STUD (F.O.S.) OR FACE OF SHT'G. (F.O.S.) TYP. U.N.O. EAVE DIMS. ARE FROM FACE OF SHT'G. TO FACE
OF FINISH FASCIA
ENCLOSED ATTIC AND ENCLOSED RAFTER SPACES VENTING NOTES:
1. ENCLOSED ATTIC AND ENCLOSED RAFTER SPACES SHALL HAVE CROSS VENTILATION BY VENTILATION OPENING PROTECTED
AGAINST THE ENTRANCE OF RAIN OR SNOW UNLESS THEY MEET THE REQUIREMENT OF SECTION R806.5 FOR UNVENTED ATTIC
AND UNVENTED ENCLOSED RAFTER ASSEMBLIES. VENTILATION OPENING SHALL HAVE THE LEAST DIMENSION OF 1/16”MIN. AND
1/4”MAX OTHERWISE THE OPENING SHALL HAVE THE CORROSION-RESISTANT WIRE CLOTH SCREENING, HARDWARE CLOTH,
PERFORATED VINYL OR SIMILAR MATERIAL WITH OPENINGS HAVE A LEAST DIMENSION OF 1/16”MIN. AND 1/4”MAX. OPENING IN
ROOF FRAMING MEMBERS SHALL BE PER THE REQUIREMENT OF SECTION R802.7. REQUIRED VENTILATION OPENINGS SHALL
OPEN DIRECTLY TO THE OUTSIDE AIR AND SHALL BE PROTECTED TO PREVENT THE ENTRY OF BIRDS, RODENTS, SNAKES AND
OTHER SIMILAR CREATURES. (R806.1)
2. THE MINIMUM NET FREE VENTILATING AREA SHOULD BE 1/150 OF THE AREA OF THE VENTED SPACE, EXCEPT FOR THE PROJECT
LOCATED IN CLIMATE ZONE 14 OR 16 WITH A CLASS I OR II VAPOR RETARDER AT THE WARM-IN-WINTER SIDE OF THE CEILING
AND WHERE MIN. 40% AND MAX 50% OF THE REQUIRED VENTILATION PROVIDED IN THE UPPER PORTION OF THE ATTIC OR
RAFTER SPACE PER SECTION R806.2 THEN THE MINIMUM NET FREE VENTILATING AREA CAN BE 1/300 OF THE VENTED SPACE.
(R802.2)
3. PROVIDE 1”SPACE BETWEEN THE INSULATION AND THE ROOF SHEATHING WHERE EAVE OR CORNICE VENTS PROVIDE
BLOCKING, BRIDGING AND INSULATION SHALL NOT BLOCK THE FREE FLOW OF AIR. (R806.3)
4. INSTALL VENTILATOR PER MANUFACTURER INSTRUCTION. INSTALL VENTILATOR IN ROOF PER SECTION R903 AND VENTILATOR
IN WALL ASSEMBLIES PER SECTION R703.1.
5. FOR THE ATTIC WITH VERTICAL HEIGHT GREATER THAN OR EQUAL TO 30”(VERTICAL HEIGHT MEASURED FROM THE TOP OF
CEILING JOIST TO THE BOTTOM OF THE ROOF RAFTERS) WITHIN 30S.F. MIN. PROVIDE THE OPENING WITH ROUGH-FRAMED
OPENING OF NOT LESS THAN 22”X30”WHICH SHOULD BE LOCATED IN HALLWAY OR OTHER LOCATION WITH READY ACCESS. IF
THE ACCESS LOCATED IN THE WALL THEN THE WIDTH SHOULD BE 22”AND HEIGHT SHOULD BE 30”MIN. IF LOCATED IN CEILING
THEN THE MIN. UNOBSTRUCTED HEADROOM IN THE ATTIC SHOULD BE 30”FROM THE BOTTOM OF CEILING JOIST AT SOME POINT.
ROOF DRAINAGE:
IF THE PROJECT LOCATED IN THE AREA WITH EXPANSIVE OR COLLAPSIBLE SOILS, WATER RUNOFF FROM ROOFS OF ALL
DWELLINGS SHALL BE DISCHARGED TO THE GROUND SURFACE NOT LESS THAN 5 FEET FROM FOUNDATION WALLS OR TO AN
APPROVED DRAINAGE SYSTEM. (R801.3) -REF.CIVIL DWGS FOR STORM WATER MANAGMENT AND SYSTEM.
WEATHER PROTECTION:
1. ROOF DECKS SHALL BE COVERED WITH APPROVED ROOF COVERINGS SECURED TO THE BUILDING OR STRUCTURE IN
ACCORDANCE WITH THE CHAPTER 9 OF THE CURRENT CRC. ROOF ASSEMBLIES SHALL BE DESIGNED AND INSTALLED IN
ACCORDANCE WITH THE CHAPTER 9 OF CRC AND THE APPROVED MANUFACTURER’S INSTRUCTIONS SUCH THAT THE ROOF
ASSEMBLY SHALL SERVE TO PROTECT THE BUILDING OR STRUCTURE. (R903.1)
2. PROVIDE AND INSTALL FLASHING TO PREVENT ENTRY OF MOISTURE TO WALL AND ROOF ASSEMBLIES THRU THE JOINTS IN
COPINGS, PERMEABLE MATERIAL, AND AT INTERSECTION WITH PARAPET WALLS AND OTHER PENETRATION THRU ROOF. (R903.2)
3. FLASHINGS SHALL BE INSTALLED AT WALL AND ROOF INTERSECTIONS, WHEREVER THERE IS A CHANGE IN ROOF SLOPE OR
DIRECTION AND AROUND ROOF OPENINGS. A FLASHING SHALL BE INSTALLED TO DIVERT THE WATER AWAY FROM WHERE THE
EAVE OF A SLOPED ROOF INTERSECTS A VERTICAL SIDEWALL. WHERE FLASHING IS OF METAL, THE METAL SHALL BE CORROSION
RESISTANT WITH A THICKNESS OF NOT LESS THAN 0.019 INCH (0.5 MM) (NO. 26 GALVANIZED SHEET). (R903.2.1)
4. A CRICKET OR SADDLE SHALL BE INSTALLED ON THE RIDGE SIDE OF ANY CHIMNEY OR PENETRATION MORE THAN 30 INCHES
(762 MM) WIDE AS MEASURED PERPENDICULAR TO THE SLOPE. CRICKET OR SADDLE COVERINGS SHALL BE SHEET METAL OR OF
THE SAME MATERIAL AS THE ROOF COVERING. EXCEPT FOR UNIT SKYLIGHTS INSTALLED IN ACCORDANCE WITH HYPERLINK
"HTTPS://CODES.ICCSAFE.ORG/LOOKUP/CRC2019P1_PT03_CH03_SECR308.6" SECTION R308.6 AND FLASHED IN ACCORDANCE
WITH THE MANUFACTURER’S INSTRUCTIONS SHALL BE PERMITTED TO BE INSTALLED WITHOUT A CRICKET OR SADDLE. (R903.2)
5. PARAPET WALLS SHALL BE PROPERLY COPED WITH NONCOMBUSTIBLE, WEATHERPROOF MATERIALS OF A WIDTH NOT LESS
THAN THE THICKNESS OF THE PARAPET WALL. (R903.3)
6. UNLESS ROOFS ARE SLOPED TO DRAIN OVER ROOF EDGES, ROOF DRAINS SHALL BE INSTALLED AT EACH LOW POINT OF THE
ROOF. IF WATER CAN BE ENTRAPPED WITHIN THE ROOF AREA THEN SECONDARY EMERGENCY OVERFLOW ROOF DRAINS OR
SCUPPERS SHALL BE PROVIDED PER SECTION R903.4.1. (R903.4)
MISC. NOTES:
1. INSTALL ROOF PER ROOFING MFG'R. SPECS & INSTALLATION GUIDELINE
2. ARCH. TO APPV. SIZE, COLOR & PROFILE OF EAVE & RAKE COMPONENTS. G.C. TO PROVIDE MOCK-UPS.
3. UNVENTED ENCLOSED RAFTER ASSEMBLY: NO INTERIOR CLASS I VAPOR RETARDER SHALL BE INSTALLED ON THE CEILING SIDE
(ATTIC FLOOR) OF THE UNVENTED ATTIC ASSEMBLY OR ON THE CEILING SIDE OF THE UNVENTED ENCLOSED ROOF FRAMING
ASSEMBLY.
4. REF. WOOD OR WOODBASE PRODUCT NOTES ON FLOOR PLANS
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
GENERAL NOTESA
B KEYNOTES
BRANDON ARCHITECTS
11.30.22
ROOF PLAN
AN
T
E
P
A
R
A
R
E
S
I
D
E
N
C
E
PAUL ANTEPARA
604 VIA LIDO NORD
NEWPORT BEACH, CA 92663
HOA SUBMITTAL
604 VIA LIDO NORD
NEWPORT BEACH, CA 92663
A-3.0
TBD
KENNEDY YEAR
PROJECT NORTHTRUE NORTH
1/4" = 1'-0"1 ROOF PLAN
NO. REVISION DATE
1 <varies>
2 DECORATIVE CHIMNEY ENCLOSURE TO BE INSTALLED AND TERMINATED PER MFRG. SPEC. OF THE FACTORY-BUILT FIREPLACE
AND/OR CHIMNEY(R1005 OF CRC) - GAS VENT TO BE TERMINATED PER CMC 802.6.1 (LISTED DIRECT-VENT PER MFGR.
INSTALLATION INSTRUCTION (CMC 802.2.6))
3 PROPERTY LINE - REF. SURVEY
4 SIDE YARD SETBACK
5 FRONT YARD SETBACK
6 OUTLINE OF STRUCTURE/WALLS BELOW
7 FLAT COOL ROOF, CLASS 'A' - COLOR AS SELECTED - TPO MEMBRANE - REF. MAT. SCHEDULE SHT. A/A-4.0
8 FIREPIT - PROVIDE GAS STUB-OUT & POWER AS REQ'D., REF. LAND. DWGS., VERIFY W/. OWNER
9 CUSTOM RECESSED GUTTER/DECK DRAIN - ROOFING/DECKING CONTRACTOR COORD. W/. FLASHING INSTALLER - VERIFY
LOC'N & APPLICATION OF DRAIN W/. ARCH PRIOR TO ORDERING - SIZE PER TABLE 1103.3 OF CPC
10 EXTERIOR GLASS GUARDRAIL , TEMPERED & LAMINATED - MIN. 42" HIGH ABV.F.F. - <4" MAX. SPHERE OPENING, REF. DTL.
4/AD-1.0
11 A/C CONDENSER / HEAT PUMP - TO BE IN COMPLIANCE OF SECTION 307.3 OF CPC AS SELECTED, VERIFY W/. OWNER - SIZE
TBD, ENERGY REPORT FOR MORE INFO – PROVIDE POWER AND SOUND DAMPENING PAD AS REQ’D. – INSTALL AND MAINTAIN
REQUIRED CLEARANCES PER MFGR. INSTRUCTION
12 BUILT-IN DESK PER I.D. - FINISH AS SELECTED, VERIFY W/. I.D. AND OWNER
FIRST FLOOR (T.O.S.)
11.51'
SECOND FLOOR PLATE (TYP.)
21.68'
SECOND FLOOR PLATE (TYP.)
21.68'
SECOND FLOOR T.O.S. (TYP.)
22.76'
SECOND FLOOR T.O.S. (TYP.)
22.76'
ROOF PLATE (TYP.)
32.08'
ROOF PLATE (TYP.)
32.08'
AVERAGE TOP OF CURB (HOA)
12.83'
AVERAGE TOP OF CURB (HOA)
12.83'
GARAGE T.O.C.
13.16'
HOA MAX HEIGHT
36.83'
HOA MAX HEIGHT
36.83'
24
'
-
0
"
9'
-
7
1
/
4
"
9'
-
3
7
/
8
"
8'
-
6
1
/
4
"
1'
-
1
"
SIL
L
H
T
.
1
1
/
2
"
HD
.
H
T
.
9'
-
1
1
/
2
"
SIL
L
H
T
.
5'
-
1
1
/
2
"
HD
.
H
T
.
9'
-
1
1
/
2
"
FR
O
M
S
T
A
I
R
L
N
D
'
G
.
13
'
-
1
1
1
/
8
"
HD
.
H
T
.
9'
-
1
1
/
2
"
SIL
L
H
T
.
4'
-
1
1
/
2
"
16
16.1 15.1
15
14
13
6 7
12
4
43 11
7
10
1
12
12
6
8
MI
N
.
4
2
"
A
B
V
.
F
.
F
.
24
'
-
0
"
10
'
-
2
1
/
8
"
1'
-
1
"
9'
-
3
7
/
8
"
11
'
-
3
1
/
8
"
DECK T.O.S. (TYP.)
33.02'
DECK T.O.S. (TYP.)
33.02'
DECK PLATE (TYP.)
31.94'
DECK PLATE (TYP.)
31.94'
22' AVG ROOF
34.83'
22' AVG ROOF
34.83'
5
36.73' HT. CERT. REQ'D.36.60' HT. CERT. REQ'D.
6 .5 :1 2
P.L
P.L
12
12
HD
.
H
T
.
9'
-
1
1
/
2
"
SIL
L
H
T
.
4'
-
1
1
/
2
"
SIL
L
H
T
.
1
1
/
2
"
SI
L
L
H
T
.
F
R
M
.
S
T
A
I
R
L
N
D
'
G
.
2'
-
1
1
"
13
3
9
3.5:12
AB
V
.
F
.
F
.
42
"
M
I
N
.
1
A-5.1
1
A-5.2
1
A-5.3
2
A-5.3
15 15
36.41' HT. CERT. REQ'D.36.67' HT. CERT. REQ'D.
1
14
FIRST FLOOR (T.O.S.)
11.51'
FIRST FLOOR (T.O.S.)
11.51'
SECOND FLOOR PLATE (TYP.)
21.68'
SECOND FLOOR PLATE (TYP.)
21.68'
SECOND FLOOR T.O.S. (TYP.)
22.76'
SECOND FLOOR T.O.S. (TYP.)
22.76'
ROOF PLATE (TYP.)
32.08'
ROOF PLATE (TYP.)
32.08'
10
'
-
2
1
/
8
"
1'
-
1
"
AVERAGE TOP OF CURB (HOA)
12.83'
AVERAGE TOP OF CURB (HOA)
12.83'
HOA MAX HEIGHT
36.83'
HOA MAX HEIGHT
36.83'
11
'
-
3
1
/
8
"
9'
-
3
7
/
8
"
23
2
9'
-
1
1
/
2
"
9'
-
1
1
/
2
"
25' - 6"
17' - 6"
3
7
5 6
4
8
9
DECK T.O.S. (TYP.)
33.02'
DECK T.O.S. (TYP.)
33.02'
DECK PLATE (TYP.)
31.94'
DECK PLATE (TYP.)
31.94'
22' AVG ROOF
34.83'
22' AVG ROOF
34.83'
24
'
-
0
"
P.L.P.L.
10
'
-
2
1
/
8
"
1'
-
1
"
1
12
36.58' TOP OF CHIMNEY
6.5:1 2 6.5:12
3
AB
V
.
F
.
F
.
42
"
M
I
N
.
2
A-5.1
2
A-5.2
SECOND FLOOR PLATE (TYP.)
21.68'
SECOND FLOOR PLATE (TYP.)
21.68'
SECOND FLOOR T.O.S. (TYP.)
22.76'
SECOND FLOOR T.O.S. (TYP.)
22.76'
ROOF PLATE (TYP.)
32.08'
ROOF PLATE (TYP.)
32.08'
AVERAGE TOP OF CURB (HOA)
12.83'
AVERAGE TOP OF CURB (HOA)
12.83'
GARAGE T.O.C.
13.16'
GARAGE T.O.C.
13.16'
HOA MAX HEIGHT
36.83'
HOA MAX HEIGHT
36.83'
8'
-
6
1
/
4
"
1'
-
1
"
9'
-
7
1
/
4
"
9'
-
3
7
/
8
"
24
'
-
0
"
7'
-
1
1
/
2
"
5
7
5
36.73' HT. CERT. REQ'D.
2
10
DECK T.O.S. (TYP.)
33.02'
DECK T.O.S. (TYP.)
33.02'
DECK PLATE (TYP.)
31.94'
DECK PLATE (TYP.)
31.94'
22' AVG ROOF
34.83'
22' AVG ROOF
34.83'1 1
6 .5 :1 2 6.5:12
36.58' TOP OF CHIMNEY
10 P.L.P.L.
1313
8'
-
6
1
/
4
"
1'
-
1
"
5.5:12
36.73' HT. CERT. REQ'D.
3' - 3"3' - 4"
3.5:123.5 :1 2
2'
-
0
"
7
8
3
2
A-5.1
2
A-5.2
36.41'
18 19
7 7
FIRST FLOOR (T.O.S.)
11.51'
SECOND FLOOR PLATE (TYP.)
21.68'
SECOND FLOOR PLATE (TYP.)
21.68'
SECOND FLOOR T.O.S. (TYP.)
22.76'
SECOND FLOOR T.O.S. (TYP.)
22.76'
ROOF PLATE (TYP.)
32.08'
ROOF PLATE (TYP.)
32.08'
AVERAGE TOP OF CURB (HOA)
12.83'
AVERAGE TOP OF CURB (HOA)
12.83'
GARAGE T.O.C.
13.16'
SECOND FLOOR FINISH
22.89'
SECOND FLOOR FINISH
22.89'
HOA MAX HEIGHT
36.83'
HOA MAX HEIGHT
36.83'
9'
-
3
7
/
8
"
9'
-
7
1
/
4
"
1'
-
1
"
8'
-
6
1
/
4
"
1'
-
7
7
/
8
"
9'
-
3
7
/
8
"
11
'
-
3
1
/
8
"
1'
-
1
"
10
'
-
2
1
/
8
"
24
'
-
0
"
24
'
-
0
"
89
1011
21
SIL
L
H
T
.
2'
-
6
"
HD
.
H
T
.
9'
-
0
"
SIL
L
H
T
.
3'
-
7
1
/
2
"
5' - 0"2' - 6"
9'
-
1
1
/
2
"
9'
-
1
1
/
2
"
3' - 0"
1
2
1
3
4
5
2
6
MIN
.
4
2
"
A
B
V
.
F
.
F
.
MI
N
.
4
2
"
A
B
V
.
F
.
F
.
C
2
6
DECK T.O.S. (TYP.)
33.02'
DECK T.O.S. (TYP.)
33.02'
DECK PLATE (TYP.)
31.94'
DECK PLATE (TYP.)
31.94'
22' AVG ROOF
34.83'
22' AVG ROOF
34.83'
10 10 10
36.60' HT. CERT. REQ'D.
1
12
P.L.P.L.
HD
.
H
T
.
9'
-
1
1
/
2
"
SIL
L
H
T
.
7'
-
1
1
/
2
"
12
36.58' TOP OF CHIMNEY
6 .5 :1 2 6.5:12
9'
-
7
1
/
2
"
SI
L
L
H
T
.
5'
-
0
"
14
14
13 6
5.5 :1 23.5 :12
1
A-5.1
1
A-5.2
1
A-5.3
2
A-5.3
36.41' HT. CERT. REQ'D.36.67' HT. CERT. REQ'D.36.73' HT. CERT. REQ'D.
7
7
WINDOWS & DOORS:
AUTHORIZED DEALER (PRODUCTS LISTED BELOW)
SUPPLIER:ASSOCIATED BUILDING SUPPLY
ADDRESS:STONE MILL DESIGN CENTER 2915 RED HILL AVE., SUITE F104, COSTA MESA, CA 92626
CONTACT:JOE YOUNAN
PHONE:949-872-3319
FAX:206-666-2150
EMAIL:JYOUNAN@ABSCAL.COM
WEB:WWW.ASSOCIATEDBUILDINGSUPPLY.COM
ALUMINUM CLAD WINDOWS & PATIO DOORS
MANUFACTURER: JELD-WEN WINDOWS & DOORS
PRODUCT:CUSTOM COLLECTION
ADDRESS:3250 LAKEPORT BLVD. P.O. BOX 1329; KLAMATH FALLS, OREGON 97601
PHONE:541-885-7412 OR 800-535-3936
FAX:541-884-3331
WEB:WWW.JELD-WEN.COM
MULTI SLIDE DOORS & STOREFRONT
MANUFACTURER:WESTERN WINDOW SYSTEMS
PRODUCT: SERIES 600 & STOREFRONT SYSTEMS
ADDRESS: 5621 S. 25TH ST., PHOENIX, AZ 85040
PHONE: 877.268.1300
WEB: WWW.WESTERNWINDOWSYSTEMS.COM
STONE VENEER:
MANUFACTURER: NEOLITH
PRODUCT: STRATA ARGENTUM
COLOR: ARCH. TO APPV. SAMPLE
APPLICATION: REF. DTL. 8/AD-1
THICKNESS: 1/2" NOMINAL
WEIGHT: N/A
CODE: ESR-3669
WOOD SIDING:
MANUFACTURER: TBD
SPECIES: CEDAR, REDWOOD OR IPE ('CLEAR HEART' OR 'A CLEAR')
SIZE: 1X6
TREATMENT: STAIN & SEAL, COLOR AS SEL. (ARCH. TO APPV.) SCORE & BACK-PRIME AS NEED
COLOR: DARK BROWN
EXTERIOR STUCCO:
PRODUCT: LAHABRA
MANUFACTURER: PAREXUSA
SUPPLIER: N/A
CODE: N/A
COLOR: BLACK
APPLICATION: SMOOTH WALL, TROWELED EDGES, NO BULLNOSE,
VERTICAL FLOAT LEVEL TO 1/8"
WEIGHT: N/A
ADDRESS: 2911 ORANGE-OLIVE RD, ORANGE, CA 92865
PHONE: 800-226-2424
WEB: WWW.PAREXUSA.COM
COLOR: X-81 OATMEAL -ARCH. TO APPROVE
APPLICATION: THREE COAT APPLICATION, PROVIDE EXPANSION JOINTS (STUCCO REVEALS), WIDTH TO BE DETERMINED,
LOCATIONS TO BE SPECIFIED AND FIELD VERIFIED BY ARCH.
CODE: MIN. 7/8" THK. O/. MIN. 2-LAYERS GRADE 'D' PAPER
TEXTURE: SMOOTH WALL, TROWELED EDGES, NO BULLNOSE, VERTICAL FLOAT LEVEL TO 1/8" IN 10"
ROOFING:
PRODUCT: SLATE TILE
MFGR/SUPPLIER: TBD
COLOR: DARK GREY TO BE APPROVED BY ARCH. & OWNER
APPLICATION: CLOSED VALLEY W./ MITERED HIP CUTS, 16 GAUGE COPPER FLASHING, STAGGERED COURSING
CODE: CLASS 'A' ASSEMBLY
WEIGHT: APPX. 12 PSF
GUTTERS:
MATERIAL: METAL -COPPER/ALUM. PAINTED KYNAR
SHAPE: HALF ROUND/SQUARE (5") (VERIFY W/. ARCH.)
GARAGE DOORS:
SUPPLIER:RANCH HOUSE DOORS
WEB:WWW.RANCHHOUSEDOORS.COM
STYLE: CUSTOM
MATERIAL: CUSTOM BUILT, WOOD & GLASS
WATERPROOF DECK MEMBRANE:
MFGR: WESTCOAT
ADDRESS: 770 GATEWAY CENTER DRIVE, SAN DIEGO, CA 92101
PRODUCT: ALX WALKING DECK (CLASS 'A')
APPLICATION: DECK FINISH SURFACE TO BE NON-COMBUSTIBLE
CODE: ICC # ESR-2201
FLASHING & WEATHERSTRIPPING
PROVIDE CORROSION-RESISTANCE METAL FLASHING PER CRC FOR ALL EXTERIOR FLASHING, MIN. 24 GUAGE COPPER (16 OZ.)
SHEETS U.N.O. IN CRC OR MFGR. INSTALLATION GUIDELINES. ALL METAL IN CONTACTS TO BE OF SIMILAR TYPE TO AVOID
GALVANIC CORROSION. VERIFY W/. ARCHITECT ANY UNCONVENTIONAL ENVELOPE WATERPROOFING AREAS PRIOR TO
INSTALLATION
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
MATERIAL SPECIFICATIONSA
KEYNOTESC
GENERAL NOTESB
BRANDON ARCHITECTS
11.30.22
EXTERIOR
ELEVATIONS &
MATERIAL
SCHEDULE
AN
T
E
P
A
R
A
R
E
S
I
D
E
N
C
E
PAUL ANTEPARA
604 VIA LIDO NORD
NEWPORT BEACH, CA 92663
HOA SUBMITTAL
604 VIA LIDO NORD
NEWPORT BEACH, CA 92663
A-4.0
TBD
KENNEDY YEAR
1/4" = 1'-0"4 RIGHT SIDE ELEVATION - WEST
1/4" = 1'-0"2 FRONT ELEVATION - NORTH
1/4" = 1'-0"3 REAR ELEVATION - SOUTH
1/4" = 1'-0"1 LEFT SIDE ELEVATION - EAST
1. FENESTRATIONS MUST HAVE TEMPORARY AND PERMANENT LABELS.
2. REF. ROOF PLAN (A-3) FOR ALL PLATE HTS. & RIDGE HTS.
NO. REVISION DATE
1 SLATE TILE ROOFING - REF. MAT. SCHEDULE SHT. A/A-4.0
2 T&G PANELING - REF. MATERIAL SCHEDULE SHT. A/A-4.0
3 KYNAR PAINTED ALUMINUM - REF. MAT. SCHEDULE A/A-4.0
4 EXPOSED STEEL COLUMN SIZE PER STRUCT. DWGS., PAINT AS SELECTED AND SEAL AS REQ'D. - ARCH. TO APPV. COLOR
5 EXTERIOR GUARDRAIL - MIN. 42" HEIGHT ABV.F.F. - <4" MAX. SPHERE OPENING, REF. DTL. 4/AD-1.0
6 EXTERIOR GLASS GUARDRAIL , TEMPERED & LAMINATED - MIN. 42" HIGH ABV.F.F. - <4" MAX. SPHERE OPENING, REF. DTL.
4/AD-1.0
7 STONE VENEER - REF. MAT. SCHEDULE SHT. A/A-4.0
8 FURNISHINGS AS SELECTED PER I.D.- VERIFY APPLIANCE W/. I.D. & OWNER
9 FIREPIT - PROVIDE GAS STUB-OUT & POWER AS REQ'D., REF. LAND. DWGS., VERIFY W/. OWNER
10 EXTERIOR LIGHTING - TO BE HIGH EFFICIENCY
11 RECESSED MAIN SERVICE PANEL, 400 AMP MAX. (MAINTAIN 36" CLEAR FROM FACE OF PANEL TO ANY OBSTRUCTION)
12 STUCCO FINISH - MIN. 7/8" THK. W/. DIA. LATH, COLOR AS SEL., REF. MAT. SCHEDULE A/A-4.0
13 (N.) WOOD GATE - AS SELECTED (MAX. 6' HT. ABOVE NATURAL GRADE)
14 STONE CAP - G.C. TO PROVIDE MOCK UP FOR ARCH. APPV.
15 FASCIA PER DETAILS, ARCH TO APPV.