HomeMy WebLinkAboutPA2023-0018_20230329_CDP Resubmittal 42x30DETAIL REFERENCE SHEET NUMBER SECTION INDICATOR REVISION NUMBER REVISION REFERENCE PLAN NOTE REFERENCE NUMBER FLOOR PLAN, SOFFIT/UTILITY, &ELEVATION KEYNOTE SECTION INDICATOR SHEET NUMBER BUILDING SECTION PROPOSED USE: NEW DUPLEX NUMBER OF STORIES: 3 CONSTRUCTION TYPE: V-B OCCUPANCY: R-1 DWELLINGS, U- GARAGES FIRE SPRINKLERS: REQUIRED, CRC SEC. R313.3 SYSTEM - NFPA 13D SYSTEM THROUGHOUT INCLUDING ATTIC PER R309.6, R313.1, R313.2 & R313.3 ABBREVIATIONS X X X X X X WITHOUTW/O WROUGHT IRONWI WATER HEATERWH WINDOWWDW WOODWD WATER CLOSETWC WITHW/ WASHERW VERTICALVERT UNLESS OTHERWISE NOTEDUON UNFINISHEDUNFIN UNIFORM BUILDING CODEUBC TYPICALTYP TELEVISIONTV TOP OF WALLTOW TOP OF PAVINGTOP TOP OF MASONRYTOM TOP OF CURBTOC TONGUE AND GROOVET & G TELEPHONETEL TRASH COMPACTORTC T & B TOP AND BOTTOM SQUARESQ STANDARDSTD STAGGEREDSTAG SERVICE SINKSS SHELF AND POLES & P SLIDINGSL SIMILARSIM SHOWERSHOW SHEATHINGSHTG SINGLE HUNGSH SELECT STRUCTURALSS SC SOLID CORE ROUGH OPENINGRO ROOF JOISTRJ REQUIREDREQ'D REINFORCINGREINF REFRIGERATORREFR REDWOODRDWD ROOF DRAINRD RETURN AIR GRILLERAG RADIUSR POLY VINYL CHLORIDEPVC PRESSURE TREATEDPTDF POUNDS/SQUARE INCHPSI POUNDS/SQUARE FOOTPSF PAIRPR PLYWOODPLYWD PUSH-BUTTONPB OPTIONALOPT OPPOSITEOPP ON CENTEROC NOT TO SCALENTS NUMBERNO NOT IN CONTRACTNIC NG NATURAL GRADE MASONRY OPENINGMO MINIMUMMIN MANUFACTURERMFR MEDICINE CABINETMC MACHINE BOLTMB MAXIMUMMAX MASONRYMAS LAG BOLTLB INTERIORINT INSUL INSULATION HORIZONTALHORIZ HEADERHDR HC HOLLOW CORE GLUE LAMINATED BEAMGLB GARBAGE DISPOSALGD GALVANIZEDGALV GAUGEGA FOOTINGFTG FOOT/FEETFT FACE OF STUDFOS FACE OF MASONRYFOM FLUORESCENTFLUOR FLOORFLR FLOOR JOISTFJ FINISHFIN FUEL GAS / FINISH GRADEFG FINISH FLOORFF FOUNDATIONFDN FORCED AIR UNITFAU EXTERIOREXT EACH WAYEW EQUIPMENTEQUIP EQUALEQ ELEVATORELEV EA EACH DOWNSPOUTDS DRAWINGDWG DOWNDN DOUBLE HUNGDH DIMENSIONDIM DIAGONALDIAG DIAMETERDIA DETAILDET DRINKING FOUNTAINDF DOUBLEDBL D DRYER CONT CONTINUOUS CONST CONSTRUCTION CONC CONCRETE COL COLUMN CLR CLEAR CLG CEILING CJ CEILING JOIST CI CAST IRON BTM BOTTOM BM BEAM BLKG BLOCKING BLDG BUILDING APPROXIMATELYAPPROX ALUMINUMAL ALTERNATEALT AIR CONDITIONINGA/C ANCHOR BOLTAB DOUGLAS FIR AD AREA DRAIN CURTAINCURT DR DOOR EL ELEVATION FD FLOOR DRAIN DISPOSALDISP GI GALVANIZED IRON GL GLASS / GLAZING LTWT LIGHTWEIGHT OSA OUTSIDE AIR TB TOWEL BAR TPD TOILET PAPER DISPENSER TEMPERED GLASSTEMP GL VTR VENT THROUGH ROOF V VOLTSGYPSUM WALLBOARDGYP BD A4.1 BUILDING SECTIONS (1/4" = 1'-0") ARCHITECTURAL A3.1 PROJECT DATA CODE COMPLIANCE: SPECIAL INSTRUCTIONS: FIRE SPRINKLER SYSTEM - NFPA 13D OBTAIN FIRE SPRINKLER PERMIT PRIOR TO CALLING FOR ROOF SHEATHING INSPECTION 2019 CALIFORNIA RESIDENTIAL CODE 2019 CALIFORNIA MECHANICAL CODE 2019 CALIFORNIA PLUMBING CODE 2019 CALIFORNIA ELECTRICAL CODE 2019 CALIFORNIA ENERGY CODE 2019 CALIFORNIA GREEN BUILDING STANDARDS CODE 2019 CALIFORNIA ENERGY EFFICIENCY STANDARDS CODE CITY OF NEWPORT BEACH REGULATIONS AND ORDINANCES A4.2 A4.3 RITNER GROUP, INC. 503 32ND STREET, SUITE 130 NEWPORT BEACH, CA 92663 (949) 584-8987PHONE: ARCHITECT RON RITNERCONTACT: OWNER: LAGUNA HILLS, CA 92653 Email: WILLIAM GUIDERO DESIGN 425 30th STREET #23 NEWPORT BEACH, CA 92663 (949) 675-2626PHONE: BILL GUIDEROCONTACT: STRUCTURAL RIGHT ENGINEERING 26040 ACERO SUITE 100 MISSION VIEJO, CA 92691 (949) 855-2300PHONE: CONTACT: RAID GHOULI INDEX OF DRAWINGS COVER SHEET A5.1 EXTERIOR ELEVATIONS (1/4" = 1'-0") PROJECT DIRECTORY BARNARD FAMILY TRUST 26081 MERIT CIRCLE #113 CONTACT: STEPANIE BARNARD A2.2 THIRD LEVEL FLOOR PLAN (1/4" = 1'-0")A2.3 DEFERRED SUBMITTALS: FIRE SPRINKLER - NFPA 13D SYSTEM THROUGHOUT INCLUDING ATTIC HVAC EQUIPMENT AND DUCTWORK ENCROACHMENT PERMIT PLOT REFERENCE DATE: 03-29-23 SHEET NUMBER: 503 32ND STREET, SUITE 130 TELEPHONE: (949) 584-8987 NEWPORT BEACH, CA 92663 Email: ritnergroup.com STAMP: TELEPHONE: FAX: C1.1 SHEET TITLE: ‹RITNER GROUP, INC. 2023 expressly reserves all common law copyright and property rights in these plans. These plans are not to be reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party without first obtaining the express written permission and consent of RITNER GROUP, INC. PROJECT DESIGNER: PROJECT CAD FILE: PROJECT NUMBER: DRAWN BY: PROJECT MANAGER: 22012-COVER O: \ 2 0 2 2 - P R O J E C T S \ 2 2 0 1 2 \ C D \ 2 2 0 1 2 - C O V E R Ma r c h 2 9 , 2 0 2 3 BG RR 22012 Lot 4, Block 39 Pr o g r e s s S e t / 0 3 - 2 9 - 2 3 PROJECT: BUILDING DEPARTMENT SUBMITTAL: - REVISIONS: --- N ROOF PLAN (1/4" = 1'-0") BUILDING SECTIONS (1/4" = 1'-0") BUILDING SECTIONS (1/4" = 1'-0") GENERAL NOTES: 1.THE UTILITY CONSULTING ENGINEER IS TO ATTEND ON-SITE MEETINGS WITH THE UTILITY COMPANIES TO DETERMINE ALLOWABLE LOCATIONS. A MINIMUM OF 48 HOURS WRITTEN NOTICE FOR THE MEETING IS REQUIRED. 2.REQUIRED HERS TESTING AND/OR VERIFICATION MUST BE DONE BY A CERTIFIED HOME ENERGY RATER UNDER THE SUPERVISION OF A CEC-APPROVED HERS PROVIDER USING CEC APPROVED TESTING AND/OR VERIFICATION METHODS AND MUST BE REPORTED ON THE CF-4R INSTALLATION CERTIFICATE. 3.ISSUANCE OF A BUILDING PERMIT BY THE CITY OF NEWPORT BEACH DOES NOT RELIEVE APPLICANTS OF THE LEGAL REQUIREMENTS TO OBSERVE COVENANTS, CONDITIONS AND RESTRICTIONS WHICH MAY BE RECORDED AGAINST THE PROPERTY OR TO OBTAIN PLANS. YOU SHOULD CONTAC YOUR COMMUNITY ASSOCIATIONS PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION AUTHORIZED BY THIS PERMIT. 4.PRIOR TO PERFORMING ANY WORK IN THE CITY RIGHT-OF-WAY AN ENCROACHMENT PERMIT MUST BE OBTAINED FROM THE PUBLIC WORKS DEPARTMENT. 5.A Cal-OSHA PERMIT IS REQUIRED FOR EXCAVATIONS DEEPER THAN 5'-0" AND FOR SHORING AND UNDERPINNING. CONTRACTOR TO PROVIDE A COPY OF OSHA PERMIT. 6.THE PROJECT LANDSCAPE AREA SHALL BE LESS THAN 500 sf 7.POOLS, SPAS, WALLS, FENCES, PATIO COVERS AND OTHER FREESTANDING STRUCTURES REQUIRE SEPARATE REVIEWS AND PERMITS. 8.FENCES, HEDGES, WALLS, RETAINING WALLS, GUARDRAILS AND HANDRAILS OR ANY COMBINATION THEREOF SHALL NOT EXCEED 42" FROM EXISTING GRADE PRIOR TO CONSTRUCTION WITHIN THE REQUIRED FRONT YARD SETBACK AREA. 9.ALL PERMITS RELATED TO THE PROPOSED PROJECT SHALL BE ISSUED AT THE SAME TIME, OR SEPARATE PLANS AND PLAN REVIEW WILL BE REQUIRED FOR ITEMS NOT ISSUED WITH THIS REVIEW. a.ACCESSORY STRUCTURES, DETACHED PATIO COVERS AND TRELLIS b.MASONRY OR CONCRETE FENCES OVER 3.5 FT HIGH c.RETAINING WALLS OVER 4' FROM BOTTOM OF FOUNDATION TO TOP OF WALL RECYCLE AND OR SALVAGE FOR REUSE A MINIMUM OF 65% OF THE NON-HAZARDOUS CONSTRUCTION AND DEMOLITION WASTE IN ACCORDANCE WITH SECTION 4.408.1 CalGreen CODE. DEFERRED SUBMITTAL TO BE REVIEWED BY PROJECT ARCHITECT OR ENGINEER OF RECORD AND CERTIFIED PRIOR TO SUBMITTAL FOR PLAN CHECK OR APPROVAL BY THE CITY. PROJECT DESCRIPTION: 10. 11. SOILS EGA CONSULTANTS 375-C MONTE VISTA AVENUE COSTA MESA, CA 92627 (949) 642-9309PHONE: DAVID WORTHINGTONCONTACT: CIVIL FORKERT ENGINEERING INC. 22311 BROOKHURST ST. # 203 HUNTINGTON BEACH, CA 62646 (714) 963-6793PHONE: CONTACT: THOMAS RUIZ T-24 HERITAGE ENERGY GROUP 470 WALD IRVINE, CA 92618 (949) 789-7221PHONE: RUDY SAINSCONTACT: LANDSCAPE ERIC FENMORE 2732 EAST COAST HIGHWAY SUITE A CORONA DEL MAR, CA 92625 (949) 673-5450PHONE: CONTACT: ERIC FENMORE C1.1 COVER SHEET LEGEND INSPECTION PROGRAM: 1.DEPUTY INSPECTORS ARE REQUIRED TO BE REGISTERED WITH THE CITY OF NEWPORT BEACH. PORTION OF WORK REQUIRING INSPECTION CONTINUOUS PERIODIC DESCRIPTION, LOCATIONS, REMARKS, ETC. X ---EXPANSION / EPOXY ANCHORS X ---ALL STRUCTURAL WELDING ---XSHEAR WALL NAILING ---XSTRUCTURAL MASONRY GROUTING, STEM AND FOOTING REINF. VICINITY MAP 2.SPECIAL AND / OR DEPUTY INSPECTIONS SHALL BE PROVIDED DURING CONSTRUCTION ON THE FOLLOWING TYPES OF WORK: --- --- --- "HERS" VERIFICATION ---X A5.2 EXTERIOR ELEVATIONS (1/4" = 1'-0") SP-1 ARCHITECTURAL SITE PLAN (1/4" = 1'-0") SECOND LEVEL FLOOR PLAN (1/4" = 1'-0") ZONING: R-2 A2.1 MAIN LEVEL FLOOR PLAN (1/4" = 1'-0") PROJECT SITE PROJECT ADDRESS 3907 SEASHORE DRIVE NEWPORT BEACH, CA. 92663 ASSESOR'S PARCEL NUMBER: 423-326-05 LOT 4, BLOCK 39 - BOOK 3, PAGE 31 CIVIL C-4 C-2 EROSION CONTROL PLAN PRECISE GRADING PLAN A9.1 MAIN LEVEL & SECOND LEVEL OVERLAY PLANS (1/4" = 1'-0") SOILS REPORT: PREPARED BY: EGA CONSULTANTS REPORT No WG411.1 DATED 12-13-22 PROJECT SCOPE: DEMOLITION OF EXISTING TWO-STORY DUPLEX, GARAGE AND ASSOCIATED LANDSCAPING. CONSTRUCT NEW THREE-STORY 2,436 s.f. DUPLEX WITH AN ATTACHED 390 s.f. TWO CAR GARAGE AND TWO CAR CARPORT. THE PROJECT INCLUDES HARDSCAPE AND SUBSURFACE DRAINAGE FACILITIES WITHIN THE CONFINES OF THE PRIVATE PROPERTY. DESIGN SURVEY 1 OF 1 TOPOGRAPHIC MAP Allowable Floor Area: Allowable combined Exception : Sec 20.48.180.A.1.b.i Planning Criteria SETBACKS: 0'Front 5'2nd Front 3'Side Yard 1 MAXIMUM HEIGHT: 24'Flat Roof (less than 3:12 pitch) 29'Pitched Roof (greater than 3:12 pitch) FAR: 2,024 Sq. Ft.Site Area MAXIMUM FLOOR AREA LIMIT: Buildable Area 2,826 Sq. Ft.Buildable Area 1,413 x 2 = 3'Side Yard 2 1,413 Sq. Ft. Development Standards R-2 Zone PARKING REQUIREMENTS: 2 Car off Street Parking Minimum Minimum Interior dimensions for Parking spaces in residential zoning for a lot width 30'-0" feet or less is 17'-6"x19'-0" (20.40) City of Newport Beach Area Tabulation Living Area: 2 Car Garage First Level Living 590 Sq.Ft.Second Level Living 568 Sq.Ft. 257 Sq.Ft.Third Level Living 1,415 Sq.Ft.Total Living Total Building Area 583 Sq.Ft. - 294 Sq.Ft. 877 Sq.Ft. Unit A Unit B 414 Sq.Ft. 1,173 Sq.Ft. 568 Sq.Ft. 551 Sq.Ft. 2,292 Sq.Ft. 2,706 Sq.Ft. Total 71 Sq.Ft.Level 2 Roof Deck 35 Sq.Ft.106 Sq.Ft. Carport 282 Sq.Ft. THIRD FLOOR LIMITATIONS: Only subsection (A)(2)(c) applyFloor & Deck Area: 15' from Front & Rear Setback LinesLocation of Structure: 388 Sq.Ft.Level 3 Roof Deck 304 Sq.Ft.692 Sq.Ft. 459 Sq.Ft.Total Roof Deck 339 Sq.Ft.798 Sq.Ft. A9.1 THIRD LEVEL & ROOF DECK OVERLAY PLANS (1/4" = 1'-0") MAP OF THIRD ADDITION TO NEWPORT BEACH BLOCK 39 M.M. 3/31 LOT 4 CL SE A S H O R E D R I V E CL ALLEY LOT 5 [B A S I S O F B E A R I N G S ] LOT 3 N52°46'30"E 79.46' N52°46'30"E 79.33' N3 9 ° 5 3 ' 3 0 " W 2 5 . 0 3 ' N3 9 ° 3 5 ' 3 0 " W 2 5 . 0 2 ' 20.02' N3 9 ° 3 5 ' 3 0 " W 2 4 . 9 7 ' N52°46'30"E BASIS OF BEARINGS THE BEARINGS SHOWN HEREON ARE BASED ON THE CENTERLINE OF SEASHORE DRIVE HAVING A BEARING OF N39°35'30"W PER RECORD OF SURVEY NO. 2016-1204, R.S.B. 290/47. VICINITY MAP BENCHMARK INFORMATION 39 0 7 S E A S H O R E D R I V E NE W P O R T B E A C H , C A 9 2 6 6 3 (A P N : 4 2 3 - 3 2 6 - 0 5 ) TO P O G R A P H I C M A P 1 1 TITLE REPORT/EASEMENT NOTES 3907 SEASHORE DRIVE NEWPORT BEACH, CA 92663 (APN: 423-326-05) NO TITLE REPORT PROVIDED LEGAL DESCRIPTION REAL PROPERTY SITUATED IN THE CITY OF NEWPORT BEACH, COUNTY OF ORANGE, STATE OF CALIFORNIA AND IS DESCRIBED AS FOLLOWS: LOT 4 AND THAT PORTION OF LOT 5 IN BLOCK 39, THIRD ADDITION TO NEWPORT BEACH, IN THE CITY OF NEWPORT BEACH, COUNTY OF ORANGE, STATE OF CALIFORNIA AS PER MAP RECORDED IN BOOK 3, PAGE 31, OF MISCELLANEOUS MAPS IN THE OFFICE OF THE COUNTY RECORDER OF SAID COUNTY, DESCRIBED AS FOLLOWS: COMMENCING AT THE MOST EASTERLY CORNER OF LOT 5, THENCE NORTHWESTERLY ALONG THE EXISTING PROPERTY LINE, 10 FEET; THENCE IN A SOUTHWESTERLY DIRECTION 25 FEET; THENCE IN A SOUTHEASTERLY DIRECTION, 1 FOOT; THENCE IN A NORTHEASTERLY DIRECTION, 25 FEET ALONG THE EXISTING PROPERTY LINES, TO THE POINT OF BEGINNING. LC EXISTING ELEVATION LEGEND ( ) AC ASPHALT PAVEMENT SEARCHED, FOUND NOTHING; SET NOTHING FS FL FINISHED SURFACE FLOWLINE FFG FINISHED FLOOR GARAGE CONCRETE SURFACE T.B.M.TEMPORARY BENCHMARK SET ON A LEAD & TAG STAMPED 'LS 5133' ELEVATION = 11.22 FEET HU N T I N G T O N B E A C H , C A L I F O R N I A 9 2 6 4 6 PH O N E : ( 7 1 4 ) 4 8 8 - 5 0 0 6 F A X : ( 7 1 4 ) 3 3 3 - 4 4 4 0 A P E X L S I N C @ G M A I L . C O M PAUL D. CRAFT, P.L.S. 8516 DATE NOTE: SECTION 8770.6 OF THE CALIFORNIA BUSINESS AND PROFESSIONS CODE STATES THAT THE USE OF THE WORD CERTIFY OR CERTIFICATION BY A LICENSED LAND SURVEYOR IN THE PRACTICE OF LAND SURVEYING OR THE PREPARATION OF MAPS, PLATS, REPORTS, DESCRIPTIONS OR OTHER SURVEYING DOCUMENTS ONLY CONSTITUTES AN EXPRESSION OF PROFESSIONAL OPINION REGARDING THOSE FACTS OR FINDINGS WHICH ARE THE SUBJECT OF THE CERTIFICATION AND DOES NOT CONSTITUTE A WARRANTY OR GUARANTEE, EITHER EXPRESSED OR IMPLIED. LICENSE RENEWAL DATE 12/31/22 S TATEOF CALI F O R NIA PAUL D O M INICK C R A FT Exp. 12/31/22 No. 8516PROFESSIONALLAND S U R V EYOR FF FINISHED FLOOR WATER VALVEWV EG EDGE OF GUTTER GAS METERGM CENTERLINE TS TOP OF STEP GRAPHIC SCALE SURVEYOR OR ENGINEER SHALL PERMANENTLY MONUMENT PROPERTY CORNERS OR OFFSETS BEFORE STARTING GRADING. PLEASE CALL PAUL CRAFT @ 714-488-5006 TO SCHEDULE. SURVEYOR'S NOTES BLOCK WALL NG NATURAL GROUND BENCHMARK NO: NB2-7-77 DESCRIBED BY OCS 2002 FOUND 3 3\4" OCS ALUMINUM BENCHMARK DISK STAMPED "NB2-7-77", SET IN THE SOUTHWEST CORNER OF A 7 FT. BY 4.5 FT.CONCRETE CATCH BASIN. MONUMENT IS LOCATED IN THE SOUTHEAST CORNER OF THE INTERSECTION OF SUPERIOR AVENUE AND PACIFIC COAST HIGHWAY, 400 FT. EASTERLY OF THE CENTERLINE OF SUPERIOR AVENUE AND 48 FT. SOUTHERLY OF THE CENTER MEDIAN ALONG PCH. MONUMENT IS SET LEVEL WITH THE SIDEWALK. ELEVATION: 8.565 FEET (NAVD88), YEAR LEVELED 2015 FOUND MONUMENT AS NOTED HEREON TC TOP OF CURB WOOD FENCE (WDF) EPB ELECTRICAL PULL BOX WATER METERWM - LEAD AND TAG STAMPED 'LS 5133' TVLT SCO SEWER CLEANOUT MONUMENT NOTES - LEAD AND TAG STAMPED 'LS 6902' TELEPHONE VAULT D A1-4.2 F A1-4.3 C A1-4.1 G A1-4.3 B A1-4.1 N52 46'30"E 79.46' E A1-4.2 Slope 2% FS = 11.85 High Point of Garage Finish Pad = 10.18 8" concrete 2" sand 4" gravel Concrete Garage Slab A A1-4.1 N3 9 5 3 ' 3 0 " W 2 5 . 0 3 ' N3 9 3 5 ' 3 0 " W 2 5 . 0 2 ' LOT 5 LOT 3 N52 46'30"E 79.33' Alley Se a s h o r e D r i v e 1' - 3 " 8'-103 4"8'-103 4" 54'-111 2" 1'- 3 " 1'-3"1'-3" 18 ' - 1 0 " 8' - 2 " 1'-3"8'-91 2" 54'-111 2" 7'-91 2" 8' - 2 " 22'-4" 7'-91 2"1'-3"7'-91 2" 32'-71 2" 7'-4" 2 3'-9"6'-0"7'-01 2" 1 8'-6" 76345 Slab Edge Plan SCALE: 1/4" = 1'-0" SLAB EDGE PLAN PLOT REFERENCE DATE: 03-29-23 SHEET NUMBER: 503 32ND STREET, SUITE 130 TELEPHONE: (949) 584-8987 NEWPORT BEACH, CA 92663 Email: ritnergroup.com STAMP: TELEPHONE: FAX: A1.1 SHEET TITLE: ‹RITNER GROUP, INC. 2023 expressly reserves all common law copyright and property rights in these plans. These plans are not to be reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party without first obtaining the express written permission and consent of RITNER GROUP, INC. PROJECT DESIGNER: PROJECT CAD FILE: PROJECT NUMBER: DRAWN BY: PROJECT MANAGER: 22012-FLOOR O: \ 2 0 2 2 - P R O J E C T S \ 2 2 0 1 2 \ C D \ 2 2 0 1 2 - F L O O R Ma r c h 2 9 , 2 0 2 3 BG RR 22012 Lot 4, Block 39 Pr o g r e s s S e t / 0 3 - 2 9 - 2 3 PROJECT: BUILDING DEPARTMENT SUBMITTAL: - REVISIONS: --- SLOPE TO DRAIN SLOPE TO DRAIN 1/8" PER FOOT U.N.O. FINISH SLAB TO FINISH SLAB DIMENSION NOTE: REFER TO CIVIL DRAWINGS FOR ADDITIONAL SLAB ELEVATION INFORMATION SLAB LEGEND 1. THIS ARCHITECTURAL FOUNDATION PLAN IS FOR DIMENSIONAL INFORMATION ONLY. THE CONTRACTOR SHALL REFER TO THE STRUCTURAL FOUNDATION PLAN FOR ALL STRUCTURAL REQUIREMENTS. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IF THERE IS ANY DISCREPANCY BETWEEN THE ARCHITECTURAL FOUNDATION PLAN AND THE STRUCTURAL FOUNDATION PLAN. 2. FOOTINGS SHALL BE EXAMINED AND CERTIFIED IN WRITING BY THE PROJECT SOIL / GEOLOGY ENGINEER PRIOR TO EMA INSPECTIONS AND PLACEMENT OF CONCRETE. 3. VERIFY ALL INFORMATION REGARDING CONCRETE SLAB, FOUNDATION, AND RETAINING WALLS, WITH STRUCTURAL AND CIVIL ENGINEER'S DRAWINGS. SLAB NOTES 4. REFER TO STRUCTURAL DRAWINGS FOR SHEAR WALLS AND HOLD DOWN LOCATIONS AND SIZES. 5.DEPRESSED SLAB FOR MATERIAL THICKNESS REFER TO LEGEND. 6.PROVIDE ELECTRICAL CONDUIT BELOW SLAB FOR FLOOR OUTLETS, KITCHEN ISLAND OUTLETS AND APPLIANCES. VERIFY LOCATION WITH INTERIOR DESIGN DRAWINGS 7. SURVEYOUR TO FILE A CORNER RECORD OF SURVEY WITH THE OFFICE OF COUNTY SURVEYOR. EVIDENCE OF FILING SHALL BE SUBMITTED TO BUILDING INSPECTOR PRIOR TO FOUNDATION INSPECTION. Dn 9R 5'-2" Up 10R Up 17R Dn 5R 5'-91 2" 51 2" 4' - 8 " 512" 81 2" 4'-4" 35'-0" 75'-9" 29'-1" 9'-6"20'-0" 5'-10" 8'-51 2" D A1-4.2 81 2" F A1-4.3 Pdr 5'-10"5'-91 2" 8'-51 2" 54'-111 2" C A1-4.1 9'-2" 25'-101 2" 81 2" G A1-4.3 19'-31 2" 9'-1" 75'-9" 81 2" 9'-2"10'-10" 34'-111 2" 20'-0" 19'-31 2" 20'-41 2" 35'-0" 81 2" 3'-9" 3'-71 2" 2'-4" 4'-101 2" 7'-01 2" 812" 8'-6" 812" 6'-0"3'-41 2" 13'-4" 18 ' - 1 0 " 81 2" 3' - 3 1 2" 6'-1" 17 ' - 5 " 3'-0" B A1-4.1 CLEAR Dine Entry N52 46'30"E 79.46' E A1-4.2 Kitchen Carport A Garage 3'-91 2"3'-3" F.F. El. 17.25 EL 17.25 High Point EL 11.85 FS 14.23 TOC 14.23 TOC 12.85FS 13.59 F.S. El. 17.00 Deck FS 13.32 Dn 4R 19'-0" Existing CLEAR A A1-4.1 N3 9 5 3 ' 3 0 " W 2 5 . 0 3 ' N3 9 3 5 ' 3 0 " W 2 5 . 0 2 ' 3'-3" LOT 5 LOT 3 N52 46'30"E 79.33' Se a s h o r e D r i v e 4'-9" 21 76345 6'-7" 3'-0" 4'-0" FS 14.73 Existing FS 14.73 Existing FS 13.50 Existing 11.42 FS 11.33 FS 11.27 TC 11.13 FL 11.36 TC 11.17 FL 11.50 FS12.15 FS 1.1% 1.6% 1.6% 0.8% 2.3% 11.50 FS 4.1% 5.5% 2% 1.3% 11.47 FS11.63 FS 1.7% First Level - Floor Plan SCALE: 1/4" = 1'-0" MAIN LEVEL FLOOR PLAN PLOT REFERENCE DATE: 03-29-23 SHEET NUMBER: 503 32ND STREET, SUITE 130 TELEPHONE: (949) 584-8987 NEWPORT BEACH, CA 92663 Email: ritnergroup.com STAMP: TELEPHONE: FAX: A2.1 SHEET TITLE: ‹RITNER GROUP, INC. 2023 expressly reserves all common law copyright and property rights in these plans. These plans are not to be reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party without first obtaining the express written permission and consent of RITNER GROUP, INC. PROJECT DESIGNER: PROJECT CAD FILE: PROJECT NUMBER: DRAWN BY: PROJECT MANAGER: 22012-FLOOR O: \ 2 0 2 2 - P R O J E C T S \ 2 2 0 1 2 \ C D \ 2 2 0 1 2 - F L O O R Ma r c h 2 9 , 2 0 2 3 BG RR 22012 Lot 4, Block 39 Pr o g r e s s S e t / 0 3 - 2 9 - 2 3 PROJECT: BUILDING DEPARTMENT SUBMITTAL: - REVISIONS: --- Area Tabulation Living Area: 2 Car Garage First Level Living 647 Sq.Ft.Second Level Living 588 Sq.Ft. 308 Sq.Ft.Third Level Living 1,543 Sq.Ft.Total Living Total Building Area 1,413 Sq.Ft. x 2 = 2,826 Sq.Ft.Building Lot Area: 572 Sq.Ft. - 321 Sq.Ft. 893 Sq.Ft. Unit A Unit B 390 Sq.Ft. 1,219 Sq.Ft. 588 Sq.Ft. 629 Sq.Ft. 2,436 Sq.Ft. 2,826 Sq.Ft. Total max allowable 349 Sq.Ft 25% of BuildableThird Level Roof Area: Lot Area 312 Sq.Ft.Roof Deck 214 Sq.Ft.326 Sq.Ft. FLOOR PLAN KEY NOTES SYMBOLXX A Elevation Key D C B Interior 20.PROVIDE SMOOTH METAL DUCT FOR DRYER EXHAUST EXTENDING TO OUTSIDE WITH BACKDRAFT DAMPER. PER CMC. 21.FACTORY-BUILT FIREPLACES, CHIMNEYS AND ALL OTHER COMPONENTS SHALL BE LISTED AND INSTALLED IN ACCORDANCE WITH THEIR LISTING AND MANUFACTURER INSTRUCTIONS. 22.DECORATIVE SHROUDS SHALL NOT BE INSTALLED AT THE TERMINATION OF THE FACTORY-BUILT CHIMNEYS EXCEPT WHERE SUCH SHROUDS ARE LISTED AND LABELED FOR USE WITH THE SPECIFIC FACTORY-BUILT CHIMNEY SYSTEM AND ARE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTION. CMC 802.5.2.4 GASEOUS FUEL BURNING PAN MUST BE PERMANENTLY ANCHORED TO THE FIREBOX. FIREPLACE MUST COMPLY WITH THE CALIFORNIA ENERGY STANDARDS MANDATORY MEASURES. 23.NET AREA OF SHOWER ENCLOSURES SHALL BE NOT LESS THAN 1,024 Sq In (7.1 Sq. Ftt.) OF FLOOR AREA, AND A MINIMUM OF 30 INCH DIAMETER CIRCLE. PER CPC 408.6 24.HANDRAILS: a.HANDRAILS OTHER THAN CIRCULAR CROSS SECTIONS SHALL HAVE A PERIMETER DIMENSION OF 4 TO 6.25 INCHES WITH A MAXIMUM CROSS SECTION OF 2.25 INCHES. R311.7.8.3 item 1 b.HANDRAILS WITH A PERIMETER GREATER THAN 6.25 INCHES SHALL COMPLY WITH R311.7.8.3 item 2. c.HANDRAILS SHALL BE CONTINUOUS WITHOUT INTERRUPTION BY NEWEL POST OR OTHER OBSTRUCTION, EXCEPT AT THE LANDING, VOLUTE OR TURNOUT ON LOWEST TREAD. R311.7.8.2 Exception 1&2. 1 LINE OF CABINET(S) ABOVE 2 CABINET(S) 3 OPEN SHELVES 4 BUILT-IN MILLWORK 5 KITCHEN ISLAND 6 PANTRY WITH SHELVES 7 BROOM CLOSET 8 30" FARM HOUSE SINK WITH GARBAGE DISPOSAL 9 WOLF 48" GAS RANGE / OVEN AS SELECTED BY OWNER 10 VENT HOOD TO OUTSIDE AIR 11 WOLF BUILT-IN OVEN AS SELECTED BY OWNER 12 HEARTH OVEN W/ WARMING DRAWER AS SELECTED BY OWNER 13 WOLF MICROWAVE OVEN AS SELECTED BY OWNER 14 SUB-ZERO PRO REFRIGERATOR SELECTED BY OWNER 14B SU-ZERO 24" UNDER COUNTER REFRIG SELECTED BY OWNER 15A PERLICK WINE REFRIGERATOR 15B PERLICK 24" BEVERAGE CENTER 15C PERLICK 15" ICE MAKER 16 DISHWASHER AS SELECTED BY OWNER 17 TRASH RECYCLING BIN WALL LEGENDFLOOR PLAN NOTES 1.SMOKE DETECTORS SHALL BE INTERCONNECTED SUCH THAT AT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL ALARMS. SMOKE DETECTORS SHALL BE "HARD WIRED" AND SHALL BE EQUIPPED WITH A BATTERY BACK UP. CARBON MONOXIDE DETECTORS SHALL BE "HARD WIRED" AND SHALL BE EQUIPPED WITH A BATTERY BACK UP. CRC R314 & CRC R315.3 2.ROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR FIXTURES SHALL BE PROVIDED WITH AN EXHAUST FAN WITH A MINIMUM CAPACITY OF 50 cfm CBC 1203.4.2.1, CMC T4-4 3.SHOWERS AND TUB / SHOWERS SHALL BE PROVIDED WITH PRESSURE BALANCE OR THERMOSTATIC MIXING VALVE CONTROLS. PER CPC. 4.WATER CLOSETS SHALL USE NO MORE THAN 1.28 GALLONS OF WATER PER FLUSH, LAVATORIES FAUCETS NO MORE THAN 1.5 GPM AT 60 PSI, KITCHEN FAUCETS NO MORE THAN 1.8 GPM AT 60 PSI, SHOWER HEAD NO THAN 2 GPM, CGC SECTION 4.303 5.WHEN A SHOWER IS PROVIDED WITH MULTIPLE SHOWER HEADS, THE SUM OF FLOW TO ALL THE HEADS SHALL NOT EXCEED THE 20% REDUCED LIMIT, OR THE SHOWER SHALL BE DESIGNED SO THAT ONLY ONE HEAD IS ON AT A TIME. CGC 4.303.2 6.LANDSCAPE IRRIGATION WATER USE SHALL HAVE WEATHER BASED CONTROLLERS. CGC 4.304.1 7.PROVIDED WATER EFFICIENT LANDSCAPE IRRAGATION DESIGN WHERE POTABLE WATER USE DOES NOT EXCEED 65% OF THE ETo. (TIER 1) 8.A MINIMUM OF 50% OF CONSTRUCTION WASTE IS TO BE RECYCLED. CGC 4.408.1 9.THE BUILDER IS TO PROVIDE AN OPERATION MANUAL (CONTAINING INFORMATION FOR MAINTAINING APPLIANCES, ETC.) FOR THE OWNER AT THE TIME OF FINAL INSPECTION. CGC 4.410.1 10.DURING CONSTRUCTION, ENDS OF DUCT OPENINGS ARE TO BE SEALED, AND MECHANICAL EQUIPMENT IS TO BE COVERED CGC 4.504.1 11.VOC'S MUST COMPLY WITH THE LIMITATIONS LISTED IN SECTION 4.504.3 AND TABLES 4.504.1, 4.504.2, 4.504.3, AND 4.504.5 FOR: ADHESIVES, PAINTS AND COATINGS, CARPET AND COMPOSITION WOOD PRODUCTS. CGC 4.504.2 12.THE MOISTURE CONTENT OF WOOD SHALL NOT EXCEED 19% BEFORE IT IS ENCLOSED IN CONSTRUCTION. THE MOISTURE CONTENT NEEDS TO BE CERTIFIED BY ONE OF 3 METHODS SPECIFIED. BUILDING MATERIALS WITH VISIBLE SIGNS OF WATER DAMAGE SHOULD NOT BE USED IN CONSTRUCTION. THE MOISTURE CONTENT MUST BE DETERMINED BY THE CONTRACTOR BY ONE OF THE METHODS LISTED IN CGC SECTION 4.505.3 13.BATHROOM FANS SHALL BE ENERGY STAR RATED, VENTED DIRECTLY TO THE OUTSIDE AND CONTROLLED BY A HUMIDISTAT. CGC 4.506.1 14.IF PROVIDED, WHOLE HOUSE EXHAUST FANS SHALL HAVE INSULATED COVERS OR LOUVERS WHICH CLOSE THE FAN IS OFF. THE COVERS OR LOUVERS SHALL HAVE MINIMUM R4.2 INSULATION. CGC 5.507.1 15.PROVIDE NON-REMOVABLE BACKFLOW PREVENTION DEVICES AT ALL EXTERIOR HOSE BIBS. PER CPC. 16.PROVIDE PRESSURE RELIEF VALVE WITH DRAIN TO OUTSIDE AT WATER HEATERS. PER CPC. 17.HEATING AND AC SHALL BE SIZED AND SELECTED BY ACCA MANUAL J OR ASHRAE HANDBOOK OR EQUIVALENT. THE DUCT SHALL BE SIZED IN ACCORDANCE WIHT ONE OF THE ACCA METHODS LISTED IN CGC SECTION 4.507.2 18.PRIOR TO FINAL APPROVAL OF THE BUILDING LICENSED CONTRACTOR, ARCHITECT OR ENGINEER IN RESPOSIBLE CHARGE OF THE OVERALL CONSTRUCTION MUST COMPLETE AND SIGN THE GREEN BUILDING STANDARDS CERTIFICATION FORM AND GIVEN TO THE BUILDING DEPARTMENT OFFICAL TO BE FILED WITH THE APPROVED PLANS. 19.PROVIDE FIRE BLOCKS AND DRAFT STOPS IN THE WOOD FRAME FLOOR CONSTRUCTION CONTAINING CONCEALED SPACE WHERE THERE IS USABLE SPACE ABOVE AND BELOW THE CONCEALED SPACE. SUCH DRAFT STOPS SHOULD BE INSTALLED SO THAT THE AREA OF THE CONCEALED SPACE DOES NOT EXCEED 1000 SQ. FT. DRAFTSTOPPING SHOULD DIVIDE THE CONCEALED SPACE INTO APPROXIMATELY EQUAL AREAS. PER CBC. 18 DIRECT VENT TERMINATION CAP 19A PREFABRICATED METAL FIREPLACE: BY:"ORTAL" MODEL ORTAL MINIMAL 130 TRADITIONAL 42" GAS ONLY DIRECT VENT OR APPROVED EQUAL. INSTALL IN ACCORDANCE WITH THE MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS, AND APPLICABLE CODES ANSI Z21.88/CSA 2.33a 19B PREFABRICATED METAL FIREPLACE: BY:"MAJESTIC" MODEL ODCOUG-36 MAJESTIC COURTYARD 36 GAS ONLY OUTDOOR VENT-FREE OR APPROVED EQ. INSTALL IN ACCORDANCE WITH THE MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS, AND APPLICABLE CODES. ANSI Z221.97-2014, CSA 2.41-2014 19C PREFABRICATED MODULAR FIREPLACE: BY: "ISOKERN" MODEL 42" STANDARD GAS BURNING FIREBOX OR APPROVED EQUAL INSTALL IN ACCORDANCE WITH THE MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS, AND APPLICABLE CODES. ICC REPORT NO. ESR-2316 20 FIREPLACE HEARTH 21 STONE VENEER 22 STONE TRIM 23 EXTERIOR FINISH OPENING 24 FLAT DRYWALL OPENING 25 FLAT CASED OPENING 26 3" THICK WOOD SHELVES 27 DECORATIVE WOOD BEAMS 28 SOLID SURFACE COUNTER TOP 29 HANDRAIL ONE HOUR CONSTRUCTION LOW WALL 2 X 6 STUD WALL 2 X 4 STUD WALL 2 X 8 STUD WALL 30 GUARDRAIL 31 LOW WALL 32 LOW LINEN 33 LINE OF STAIR 34 SHELF AND POLE 35 DOUBLE SHELF AND POLE 36 LAVATORY 36B PEDESTAL SINK 37 FREE STANDING TUB 38 MUDSET CERAMIC TILE SEAT 39 HOT MOPPED SHOWER PAN WITH MUDSET CERAMIC TILED WAINSCOT TO 84" AFF W/ PRESSURE BALANCE THERMOSTATIC MIXING VALVE 40 BUILT-IN SOAP NICHE 41 TEMPERED GLASS SHOWER DOOR 42 TUB / SHOWER WITH MUDSET CERAMIC TILED WAINSCOT WITH PRESSURE BALANCE THERMOSTATIC MIXING VALVE 43 MEDICINE CABINET 44 WATER CLOSET TO BE 30" MIN WIDE WITH 24" IN FRONT OF TOILET. LOW FLUSH TOILETS 1.28 GALLONS PER FLUSH 45 BAR SINK 46 LAUNDRY SINK 47 WASHER SPACE. PROVIDE RECESSED HOT AND COLD WATER BIBBS, PROVIDE FLOOR DRAIN. 48 DRYER SPACE. PROVIDE DRYER VENT TO OUTSIDE AIR PER CMC 49 INSTANTANEOUS TANKLESS WATER HEATER .94 EF / 199,000 Btu/hr 50 MECHANICAL EQUIPMENT 51 TRENCH DRAIN 52 ATTIC ACCESS 53 ROOF ACCESS 54 LINE OF FLOOR ABOVE 55 FLOOR DRAIN 56 ROOF DRAIN 57 STUCCO OVER CMU WALL REFER TO LANDSCAPE PLANS 58 42" HIGH MINIMUM GUARDRAIL WALL 59 STUCCO OVER WOOD FRAMED MECHANICAL SCREEN WALL 60 BUILT-UP ROOFING AT MECHANICAL WELL 61 ROOF MOUNTED AC UNIT REFER TO MECHANICAL PLANS 62 STONE PAVER OVER CONCRETE SLAB BASE REFER TO CIVIL AND LANDSCAPE PLANS 63 IPE WOOD LANDING REFER TO LANDSCAPE PLANS 64 6' TALL IPE WOOD FENCE REFER TO LANDSCAPE PLANS 65 LINE OF STUCCO SHELF BELOW REFER TO SHEETS T24-1a & T24-1b FOR CF1R FORMS AND COMPLIANCE INFORMATION I N S U L A T I O N S C H E D U L E Construction Name Surface Type Construction Type Framing Total Cavity Winter Design R-Value U-Value Garage Roof Volume Ceilings Wood Framed Ceiling 2x4 @ 16" o/c None 0.332 Garage Exterior Wall Exterior Walls Wood Framed Wall 2x6 @ 16" o/c None 0.347 R-30 Roof Volume Ceilings Wood Framed Ceiling 2x10 @ 16" o/c R-30 0.036 R-22 Roof Volume Ceilings Wood Framed Ceiling 2x4 @ 16" o/c R-22 0.056 R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16" o/c R-21 0.069 R-21 Wall 1 Interior Walls Wood Framed Wall 2x6 @ 16" o/c R-21 0.064 Attic / Roof / Zone 2 Attic Roofs Wood Framed Ceiling 2x4 Truss @ 24" o/c R-30 0.040 R-30 Roof HPA Ceilings Below Attic Wood Framed Ceiling 2x6 @ 24" o/c None 0.478 R-30 Floor Exterior Floors Wood Framed Floor 2x10 @ 24" o/c R-30 0.033No Crawlspace R-19 Floor No Crawlspace Interior Floors Wood Framed Floor 2x6 @ 16" o/c R-19 0.049 NOTE:BUILDING SETBACK DIMENSION IS TO FACE OF FINISH MATERIAL Dn 10R Up 14R 75'-9" 51 2"312" 5'-2" 4'- 8 " Dn 17R Up 15R D A1-4.2 F A1-4.3 25'-6" 3'-8" 3'-9" 31'-41 2" 7'-11" 12'-3"19'-11 2" 3'-9"10'-11 2" 34'-6" 9'-41 2" 3'-7"7'-71 2" 5'-0" 4'-3" 6'-41 2" 11'-111 2" 75'-9" 10" 16'-11 2" 3'-71 2" 4'-8"11'-5" Master Suite 2'-9" 3'-9" 1'-5"4'-81 2" 8'-4" 10'-2" 6'-5" 6'-3" 12'-3"22'-3" 2'-8" 21'-1" 4'-9"4'-31 2"1'-61 2"3'-91 2"3'-101 2"7'-6" 12'-1"9'-0" 10" 6' - 2 " 3'-2" 7' - 0 " 18 ' - 1 0 " Bed 2 5'-71 2" 11 ' - 1 0 " 10 " Ba 2 Ma Bath Bed 2 Wic 4'-2" Kit Ba 2 Family A C A1-4.1 G A1-4.3 B A1-4.1 N52 46'30"E 79.46' B E A1-4.2 F.F. El. 20.01 F.F. El. 27.25 A A1-4.1 N3 9 5 3 ' 3 0 " W 2 5 . 0 3 ' 3' - 4 1 2" 4'-6" N3 9 3 5 ' 3 0 " W 2 5 . 0 2 ' LOT 5 LOT 3 N52 46'30"E 79.33' 21 76345 3'-91 2"3'-10" 3'-0" Second Level - Floor Plan SCALE: 1/4" = 1'-0" SECOND LEVEL FLOOR PLAN PLOT REFERENCE DATE: 03-29-23 SHEET NUMBER: 503 32ND STREET, SUITE 130 TELEPHONE: (949) 584-8987 NEWPORT BEACH, CA 92663 Email: ritnergroup.com STAMP: TELEPHONE: FAX: A2.2 SHEET TITLE: ‹RITNER GROUP, INC. 2023 expressly reserves all common law copyright and property rights in these plans. These plans are not to be reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party without first obtaining the express written permission and consent of RITNER GROUP, INC. PROJECT DESIGNER: PROJECT CAD FILE: PROJECT NUMBER: DRAWN BY: PROJECT MANAGER: 22012-FLOOR O: \ 2 0 2 2 - P R O J E C T S \ 2 2 0 1 2 \ C D \ 2 2 0 1 2 - F L O O R Ma r c h 2 9 , 2 0 2 3 BG RR 22012 Lot 4, Block 39 Pr o g r e s s S e t / 0 3 - 2 9 - 2 3 PROJECT: BUILDING DEPARTMENT SUBMITTAL: - REVISIONS: --- Area Tabulation Living Area: 2 Car Garage First Level Living 647 Sq.Ft.Second Level Living 588 Sq.Ft. 308 Sq.Ft.Third Level Living 1,543 Sq.Ft.Total Living Total Building Area 1,413 Sq.Ft. x 2 = 2,826 Sq.Ft.Building Lot Area: 572 Sq.Ft. - 321 Sq.Ft. 893 Sq.Ft. Unit A Unit B 390 Sq.Ft. 1,219 Sq.Ft. 588 Sq.Ft. 629 Sq.Ft. 2,436 Sq.Ft. 2,826 Sq.Ft. Total max allowable 349 Sq.Ft 25% of BuildableThird Level Roof Area: Lot Area 312 Sq.Ft.Roof Deck 214 Sq.Ft.326 Sq.Ft. FLOOR PLAN KEY NOTES SYMBOLXX A Elevation Key D C B Interior 20.PROVIDE SMOOTH METAL DUCT FOR DRYER EXHAUST EXTENDING TO OUTSIDE WITH BACKDRAFT DAMPER. PER CMC. 21.FACTORY-BUILT FIREPLACES, CHIMNEYS AND ALL OTHER COMPONENTS SHALL BE LISTED AND INSTALLED IN ACCORDANCE WITH THEIR LISTING AND MANUFACTURER INSTRUCTIONS. 22.DECORATIVE SHROUDS SHALL NOT BE INSTALLED AT THE TERMINATION OF THE FACTORY-BUILT CHIMNEYS EXCEPT WHERE SUCH SHROUDS ARE LISTED AND LABELED FOR USE WITH THE SPECIFIC FACTORY-BUILT CHIMNEY SYSTEM AND ARE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTION. CMC 802.5.2.4 GASEOUS FUEL BURNING PAN MUST BE PERMANENTLY ANCHORED TO THE FIREBOX. FIREPLACE MUST COMPLY WITH THE CALIFORNIA ENERGY STANDARDS MANDATORY MEASURES. 23.NET AREA OF SHOWER ENCLOSURES SHALL BE NOT LESS THAN 1,024 Sq In (7.1 Sq. Ftt.) OF FLOOR AREA, AND A MINIMUM OF 30 INCH DIAMETER CIRCLE. PER CPC 408.6 24.HANDRAILS: a.HANDRAILS OTHER THAN CIRCULAR CROSS SECTIONS SHALL HAVE A PERIMETER DIMENSION OF 4 TO 6.25 INCHES WITH A MAXIMUM CROSS SECTION OF 2.25 INCHES. R311.7.8.3 item 1 b.HANDRAILS WITH A PERIMETER GREATER THAN 6.25 INCHES SHALL COMPLY WITH R311.7.8.3 item 2. c.HANDRAILS SHALL BE CONTINUOUS WITHOUT INTERRUPTION BY NEWEL POST OR OTHER OBSTRUCTION, EXCEPT AT THE LANDING, VOLUTE OR TURNOUT ON LOWEST TREAD. R311.7.8.2 Exception 1&2. 1 LINE OF CABINET(S) ABOVE 2 CABINET(S) 3 OPEN SHELVES 4 BUILT-IN MILLWORK 5 KITCHEN ISLAND 6 PANTRY WITH SHELVES 7 BROOM CLOSET 8 30" FARM HOUSE SINK WITH GARBAGE DISPOSAL 9 WOLF 48" GAS RANGE / OVEN AS SELECTED BY OWNER 10 VENT HOOD TO OUTSIDE AIR 11 WOLF BUILT-IN OVEN AS SELECTED BY OWNER 12 HEARTH OVEN W/ WARMING DRAWER AS SELECTED BY OWNER 13 WOLF MICROWAVE OVEN AS SELECTED BY OWNER 14 SUB-ZERO PRO REFRIGERATOR SELECTED BY OWNER 14B SU-ZERO 24" UNDER COUNTER REFRIG SELECTED BY OWNER 15A PERLICK WINE REFRIGERATOR 15B PERLICK 24" BEVERAGE CENTER 15C PERLICK 15" ICE MAKER 16 DISHWASHER AS SELECTED BY OWNER 17 TRASH RECYCLING BIN WALL LEGENDFLOOR PLAN NOTES 1.SMOKE DETECTORS SHALL BE INTERCONNECTED SUCH THAT AT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL ALARMS. SMOKE DETECTORS SHALL BE "HARD WIRED" AND SHALL BE EQUIPPED WITH A BATTERY BACK UP. CARBON MONOXIDE DETECTORS SHALL BE "HARD WIRED" AND SHALL BE EQUIPPED WITH A BATTERY BACK UP. CRC R314 & CRC R315.3 2.ROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR FIXTURES SHALL BE PROVIDED WITH AN EXHAUST FAN WITH A MINIMUM CAPACITY OF 50 cfm CBC 1203.4.2.1, CMC T4-4 3.SHOWERS AND TUB / SHOWERS SHALL BE PROVIDED WITH PRESSURE BALANCE OR THERMOSTATIC MIXING VALVE CONTROLS. PER CPC. 4.WATER CLOSETS SHALL USE NO MORE THAN 1.28 GALLONS OF WATER PER FLUSH, LAVATORIES FAUCETS NO MORE THAN 1.5 GPM AT 60 PSI, KITCHEN FAUCETS NO MORE THAN 1.8 GPM AT 60 PSI, SHOWER HEAD NO THAN 2 GPM, CGC SECTION 4.303 5.WHEN A SHOWER IS PROVIDED WITH MULTIPLE SHOWER HEADS, THE SUM OF FLOW TO ALL THE HEADS SHALL NOT EXCEED THE 20% REDUCED LIMIT, OR THE SHOWER SHALL BE DESIGNED SO THAT ONLY ONE HEAD IS ON AT A TIME. CGC 4.303.2 6.LANDSCAPE IRRIGATION WATER USE SHALL HAVE WEATHER BASED CONTROLLERS. CGC 4.304.1 7.PROVIDED WATER EFFICIENT LANDSCAPE IRRAGATION DESIGN WHERE POTABLE WATER USE DOES NOT EXCEED 65% OF THE ETo. (TIER 1) 8.A MINIMUM OF 50% OF CONSTRUCTION WASTE IS TO BE RECYCLED. CGC 4.408.1 9.THE BUILDER IS TO PROVIDE AN OPERATION MANUAL (CONTAINING INFORMATION FOR MAINTAINING APPLIANCES, ETC.) FOR THE OWNER AT THE TIME OF FINAL INSPECTION. CGC 4.410.1 10.DURING CONSTRUCTION, ENDS OF DUCT OPENINGS ARE TO BE SEALED, AND MECHANICAL EQUIPMENT IS TO BE COVERED CGC 4.504.1 11.VOC'S MUST COMPLY WITH THE LIMITATIONS LISTED IN SECTION 4.504.3 AND TABLES 4.504.1, 4.504.2, 4.504.3, AND 4.504.5 FOR: ADHESIVES, PAINTS AND COATINGS, CARPET AND COMPOSITION WOOD PRODUCTS. CGC 4.504.2 12.THE MOISTURE CONTENT OF WOOD SHALL NOT EXCEED 19% BEFORE IT IS ENCLOSED IN CONSTRUCTION. THE MOISTURE CONTENT NEEDS TO BE CERTIFIED BY ONE OF 3 METHODS SPECIFIED. BUILDING MATERIALS WITH VISIBLE SIGNS OF WATER DAMAGE SHOULD NOT BE USED IN CONSTRUCTION. THE MOISTURE CONTENT MUST BE DETERMINED BY THE CONTRACTOR BY ONE OF THE METHODS LISTED IN CGC SECTION 4.505.3 13.BATHROOM FANS SHALL BE ENERGY STAR RATED, VENTED DIRECTLY TO THE OUTSIDE AND CONTROLLED BY A HUMIDISTAT. CGC 4.506.1 14.IF PROVIDED, WHOLE HOUSE EXHAUST FANS SHALL HAVE INSULATED COVERS OR LOUVERS WHICH CLOSE THE FAN IS OFF. THE COVERS OR LOUVERS SHALL HAVE MINIMUM R4.2 INSULATION. CGC 5.507.1 15.PROVIDE NON-REMOVABLE BACKFLOW PREVENTION DEVICES AT ALL EXTERIOR HOSE BIBS. PER CPC. 16.PROVIDE PRESSURE RELIEF VALVE WITH DRAIN TO OUTSIDE AT WATER HEATERS. PER CPC. 17.HEATING AND AC SHALL BE SIZED AND SELECTED BY ACCA MANUAL J OR ASHRAE HANDBOOK OR EQUIVALENT. THE DUCT SHALL BE SIZED IN ACCORDANCE WIHT ONE OF THE ACCA METHODS LISTED IN CGC SECTION 4.507.2 18.PRIOR TO FINAL APPROVAL OF THE BUILDING LICENSED CONTRACTOR, ARCHITECT OR ENGINEER IN RESPOSIBLE CHARGE OF THE OVERALL CONSTRUCTION MUST COMPLETE AND SIGN THE GREEN BUILDING STANDARDS CERTIFICATION FORM AND GIVEN TO THE BUILDING DEPARTMENT OFFICAL TO BE FILED WITH THE APPROVED PLANS. 19.PROVIDE FIRE BLOCKS AND DRAFT STOPS IN THE WOOD FRAME FLOOR CONSTRUCTION CONTAINING CONCEALED SPACE WHERE THERE IS USABLE SPACE ABOVE AND BELOW THE CONCEALED SPACE. SUCH DRAFT STOPS SHOULD BE INSTALLED SO THAT THE AREA OF THE CONCEALED SPACE DOES NOT EXCEED 1000 SQ. FT. DRAFTSTOPPING SHOULD DIVIDE THE CONCEALED SPACE INTO APPROXIMATELY EQUAL AREAS. PER CBC. 18 DIRECT VENT TERMINATION CAP 19A PREFABRICATED METAL FIREPLACE: BY:"ORTAL" MODEL ORTAL MINIMAL 130 TRADITIONAL 42" GAS ONLY DIRECT VENT OR APPROVED EQUAL. INSTALL IN ACCORDANCE WITH THE MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS, AND APPLICABLE CODES ANSI Z21.88/CSA 2.33a 19B PREFABRICATED METAL FIREPLACE: BY:"MAJESTIC" MODEL ODCOUG-36 MAJESTIC COURTYARD 36 GAS ONLY OUTDOOR VENT-FREE OR APPROVED EQ. INSTALL IN ACCORDANCE WITH THE MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS, AND APPLICABLE CODES. ANSI Z221.97-2014, CSA 2.41-2014 19C PREFABRICATED MODULAR FIREPLACE: BY: "ISOKERN" MODEL 42" STANDARD GAS BURNING FIREBOX OR APPROVED EQUAL INSTALL IN ACCORDANCE WITH THE MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS, AND APPLICABLE CODES. ICC REPORT NO. ESR-2316 20 FIREPLACE HEARTH 21 STONE VENEER 22 STONE TRIM 23 EXTERIOR FINISH OPENING 24 FLAT DRYWALL OPENING 25 FLAT CASED OPENING 26 3" THICK WOOD SHELVES 27 DECORATIVE WOOD BEAMS 28 SOLID SURFACE COUNTER TOP 29 HANDRAIL ONE HOUR CONSTRUCTION LOW WALL 2 X 6 STUD WALL 2 X 4 STUD WALL 2 X 8 STUD WALL 30 GUARDRAIL 31 LOW WALL 32 LOW LINEN 33 LINE OF STAIR 34 SHELF AND POLE 35 DOUBLE SHELF AND POLE 36 LAVATORY 36B PEDESTAL SINK 37 FREE STANDING TUB 38 MUDSET CERAMIC TILE SEAT 39 HOT MOPPED SHOWER PAN WITH MUDSET CERAMIC TILED WAINSCOT TO 84" AFF W/ PRESSURE BALANCE THERMOSTATIC MIXING VALVE 40 BUILT-IN SOAP NICHE 41 TEMPERED GLASS SHOWER DOOR 42 TUB / SHOWER WITH MUDSET CERAMIC TILED WAINSCOT WITH PRESSURE BALANCE THERMOSTATIC MIXING VALVE 43 MEDICINE CABINET 44 WATER CLOSET TO BE 30" MIN WIDE WITH 24" IN FRONT OF TOILET. LOW FLUSH TOILETS 1.28 GALLONS PER FLUSH 45 BAR SINK 46 LAUNDRY SINK 47 WASHER SPACE. PROVIDE RECESSED HOT AND COLD WATER BIBBS, PROVIDE FLOOR DRAIN. 48 DRYER SPACE. PROVIDE DRYER VENT TO OUTSIDE AIR PER CMC 49 INSTANTANEOUS TANKLESS WATER HEATER .94 EF / 199,000 Btu/hr 50 MECHANICAL EQUIPMENT 51 TRENCH DRAIN 52 ATTIC ACCESS 53 ROOF ACCESS 54 LINE OF FLOOR ABOVE 55 FLOOR DRAIN 56 ROOF DRAIN 57 STUCCO OVER CMU WALL REFER TO LANDSCAPE PLANS 58 42" HIGH MINIMUM GUARDRAIL WALL 59 STUCCO OVER WOOD FRAMED MECHANICAL SCREEN WALL 60 BUILT-UP ROOFING AT MECHANICAL WELL 61 ROOF MOUNTED AC UNIT REFER TO MECHANICAL PLANS 62 STONE PAVER OVER CONCRETE SLAB BASE REFER TO CIVIL AND LANDSCAPE PLANS 63 IPE WOOD LANDING REFER TO LANDSCAPE PLANS 64 6' TALL IPE WOOD FENCE REFER TO LANDSCAPE PLANS 65 LINE OF STUCCO SHELF BELOW REFER TO SHEETS T24-1a & T24-1b FOR CF1R FORMS AND COMPLIANCE INFORMATION I N S U L A T I O N S C H E D U L E Construction Name Surface Type Construction Type Framing Total Cavity Winter Design R-Value U-Value Garage Roof Volume Ceilings Wood Framed Ceiling 2x4 @ 16" o/c None 0.332 Garage Exterior Wall Exterior Walls Wood Framed Wall 2x6 @ 16" o/c None 0.347 R-30 Roof Volume Ceilings Wood Framed Ceiling 2x10 @ 16" o/c R-30 0.036 R-22 Roof Volume Ceilings Wood Framed Ceiling 2x4 @ 16" o/c R-22 0.056 R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16" o/c R-21 0.069 R-21 Wall 1 Interior Walls Wood Framed Wall 2x6 @ 16" o/c R-21 0.064 Attic / Roof / Zone 2 Attic Roofs Wood Framed Ceiling 2x4 Truss @ 24" o/c R-30 0.040 R-30 Roof HPA Ceilings Below Attic Wood Framed Ceiling 2x6 @ 24" o/c None 0.478 R-30 Floor Exterior Floors Wood Framed Floor 2x10 @ 24" o/c R-30 0.033No Crawlspace R-19 Floor No Crawlspace Interior Floors Wood Framed Floor 2x6 @ 16" o/c R-19 0.049 NOTE:BUILDING SETBACK DIMENSION IS TO FACE OF FINISH MATERIAL 2'-6" Dn 14R Up 4R 5'-71 2" D A1-4.2 F A1-4.3 Dn 15R 16'-8" Up 10R 56 3'-11" 6'-21 2" 5'-31 2" 15'-7" 18'-0"57'-9" 1'-71 2" 75'-9" 5'-1" 3'-91 2" 3'-71 2"8'-5" 6'-1" 12'-61 2" 16'-4" 75'-9" 57'-9" 1'-11" 4'-2" 6'-3" 18'-0" 4'-2"7'-21 4" 11 ' - 6 1 2" 1'-101 2" 3' - 1 1 2" 3'-71 2" 7' - 3 1 2" 13'-10" 3'-10"1'-3"4'-91 4" 18 ' - 1 0 " 5' - 3 1 2" 7'-11" 4' - 2 " 1'-81 2" 18 ' - 1 0 " 2' - 1 " 4' - 2 " 3'- 1 " 3' - 1 " Office B C A1-4.1 G A1-4.3 B A1-4.1 N52 46'30"E 79.46' A Ba 2 Ma Bedroom open to below Ma Bath E A1-4.2 Roof Deck 3'-2" F.F. El. 36.50 AtticF.F. El. 28.93 A A1-4.1 N3 9 5 3 ' 3 0 " W 2 5 . 0 3 ' N3 9 3 5 ' 3 0 " W 2 5 . 0 2 ' LOT 5 LOT 3 N52 46'30"E 79.33' Alley Se a s h o r e D r i v e 7'-2" 8" 6'-01 2" 6'-6" 21 76345 14 ' - 4 " A / C 3'-0"15'-0" Third Level - Floor Plan SCALE: 1/4" = 1'-0" THIRD LEVEL FLOOR PLAN PLOT REFERENCE DATE: 03-29-23 SHEET NUMBER: 503 32ND STREET, SUITE 130 TELEPHONE: (949) 584-8987 NEWPORT BEACH, CA 92663 Email: ritnergroup.com STAMP: TELEPHONE: FAX: A2.3 SHEET TITLE: ‹RITNER GROUP, INC. 2023 expressly reserves all common law copyright and property rights in these plans. These plans are not to be reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party without first obtaining the express written permission and consent of RITNER GROUP, INC. PROJECT DESIGNER: PROJECT CAD FILE: PROJECT NUMBER: DRAWN BY: PROJECT MANAGER: 22012-FLOOR O: \ 2 0 2 2 - P R O J E C T S \ 2 2 0 1 2 \ C D \ 2 2 0 1 2 - F L O O R Ma r c h 2 9 , 2 0 2 3 BG RR 22012 Lot 4, Block 39 Pr o g r e s s S e t / 0 3 - 2 9 - 2 3 PROJECT: BUILDING DEPARTMENT SUBMITTAL: - REVISIONS: --- Area Tabulation Living Area: 2 Car Garage First Level Living 647 Sq.Ft.Second Level Living 588 Sq.Ft. 308 Sq.Ft.Third Level Living 1,543 Sq.Ft.Total Living Total Building Area 1,413 Sq.Ft. x 2 = 2,826 Sq.Ft.Building Lot Area: 572 Sq.Ft. - 321 Sq.Ft. 893 Sq.Ft. Unit A Unit B 390 Sq.Ft. 1,219 Sq.Ft. 588 Sq.Ft. 629 Sq.Ft. 2,436 Sq.Ft. 2,826 Sq.Ft. Total max allowable 349 Sq.Ft 25% of BuildableThird Level Roof Area: Lot Area 312 Sq.Ft.Roof Deck 214 Sq.Ft.326 Sq.Ft. FLOOR PLAN KEY NOTES SYMBOLXX A Elevation Key D C B Interior 20.PROVIDE SMOOTH METAL DUCT FOR DRYER EXHAUST EXTENDING TO OUTSIDE WITH BACKDRAFT DAMPER. PER CMC. 21.FACTORY-BUILT FIREPLACES, CHIMNEYS AND ALL OTHER COMPONENTS SHALL BE LISTED AND INSTALLED IN ACCORDANCE WITH THEIR LISTING AND MANUFACTURER INSTRUCTIONS. 22.DECORATIVE SHROUDS SHALL NOT BE INSTALLED AT THE TERMINATION OF THE FACTORY-BUILT CHIMNEYS EXCEPT WHERE SUCH SHROUDS ARE LISTED AND LABELED FOR USE WITH THE SPECIFIC FACTORY-BUILT CHIMNEY SYSTEM AND ARE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTION. CMC 802.5.2.4 GASEOUS FUEL BURNING PAN MUST BE PERMANENTLY ANCHORED TO THE FIREBOX. FIREPLACE MUST COMPLY WITH THE CALIFORNIA ENERGY STANDARDS MANDATORY MEASURES. 23.NET AREA OF SHOWER ENCLOSURES SHALL BE NOT LESS THAN 1,024 Sq In (7.1 Sq. Ftt.) OF FLOOR AREA, AND A MINIMUM OF 30 INCH DIAMETER CIRCLE. PER CPC 408.6 24.HANDRAILS: a.HANDRAILS OTHER THAN CIRCULAR CROSS SECTIONS SHALL HAVE A PERIMETER DIMENSION OF 4 TO 6.25 INCHES WITH A MAXIMUM CROSS SECTION OF 2.25 INCHES. R311.7.8.3 item 1 b.HANDRAILS WITH A PERIMETER GREATER THAN 6.25 INCHES SHALL COMPLY WITH R311.7.8.3 item 2. c.HANDRAILS SHALL BE CONTINUOUS WITHOUT INTERRUPTION BY NEWEL POST OR OTHER OBSTRUCTION, EXCEPT AT THE LANDING, VOLUTE OR TURNOUT ON LOWEST TREAD. R311.7.8.2 Exception 1&2. 1 LINE OF CABINET(S) ABOVE 2 CABINET(S) 3 OPEN SHELVES 4 BUILT-IN MILLWORK 5 KITCHEN ISLAND 6 PANTRY WITH SHELVES 7 BROOM CLOSET 8 30" FARM HOUSE SINK WITH GARBAGE DISPOSAL 9 WOLF 48" GAS RANGE / OVEN AS SELECTED BY OWNER 10 VENT HOOD TO OUTSIDE AIR 11 WOLF BUILT-IN OVEN AS SELECTED BY OWNER 12 HEARTH OVEN W/ WARMING DRAWER AS SELECTED BY OWNER 13 WOLF MICROWAVE OVEN AS SELECTED BY OWNER 14 SUB-ZERO PRO REFRIGERATOR SELECTED BY OWNER 14B SU-ZERO 24" UNDER COUNTER REFRIG SELECTED BY OWNER 15A PERLICK WINE REFRIGERATOR 15B PERLICK 24" BEVERAGE CENTER 15C PERLICK 15" ICE MAKER 16 DISHWASHER AS SELECTED BY OWNER 17 TRASH RECYCLING BIN WALL LEGENDFLOOR PLAN NOTES 1.SMOKE DETECTORS SHALL BE INTERCONNECTED SUCH THAT AT THE ACTIVATION OF ONE ALARM WILL ACTIVATE ALL ALARMS. SMOKE DETECTORS SHALL BE "HARD WIRED" AND SHALL BE EQUIPPED WITH A BATTERY BACK UP. CARBON MONOXIDE DETECTORS SHALL BE "HARD WIRED" AND SHALL BE EQUIPPED WITH A BATTERY BACK UP. CRC R314 & CRC R315.3 2.ROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR FIXTURES SHALL BE PROVIDED WITH AN EXHAUST FAN WITH A MINIMUM CAPACITY OF 50 cfm CBC 1203.4.2.1, CMC T4-4 3.SHOWERS AND TUB / SHOWERS SHALL BE PROVIDED WITH PRESSURE BALANCE OR THERMOSTATIC MIXING VALVE CONTROLS. PER CPC. 4.WATER CLOSETS SHALL USE NO MORE THAN 1.28 GALLONS OF WATER PER FLUSH, LAVATORIES FAUCETS NO MORE THAN 1.5 GPM AT 60 PSI, KITCHEN FAUCETS NO MORE THAN 1.8 GPM AT 60 PSI, SHOWER HEAD NO THAN 2 GPM, CGC SECTION 4.303 5.WHEN A SHOWER IS PROVIDED WITH MULTIPLE SHOWER HEADS, THE SUM OF FLOW TO ALL THE HEADS SHALL NOT EXCEED THE 20% REDUCED LIMIT, OR THE SHOWER SHALL BE DESIGNED SO THAT ONLY ONE HEAD IS ON AT A TIME. CGC 4.303.2 6.LANDSCAPE IRRIGATION WATER USE SHALL HAVE WEATHER BASED CONTROLLERS. CGC 4.304.1 7.PROVIDED WATER EFFICIENT LANDSCAPE IRRAGATION DESIGN WHERE POTABLE WATER USE DOES NOT EXCEED 65% OF THE ETo. (TIER 1) 8.A MINIMUM OF 50% OF CONSTRUCTION WASTE IS TO BE RECYCLED. CGC 4.408.1 9.THE BUILDER IS TO PROVIDE AN OPERATION MANUAL (CONTAINING INFORMATION FOR MAINTAINING APPLIANCES, ETC.) FOR THE OWNER AT THE TIME OF FINAL INSPECTION. CGC 4.410.1 10.DURING CONSTRUCTION, ENDS OF DUCT OPENINGS ARE TO BE SEALED, AND MECHANICAL EQUIPMENT IS TO BE COVERED CGC 4.504.1 11.VOC'S MUST COMPLY WITH THE LIMITATIONS LISTED IN SECTION 4.504.3 AND TABLES 4.504.1, 4.504.2, 4.504.3, AND 4.504.5 FOR: ADHESIVES, PAINTS AND COATINGS, CARPET AND COMPOSITION WOOD PRODUCTS. CGC 4.504.2 12.THE MOISTURE CONTENT OF WOOD SHALL NOT EXCEED 19% BEFORE IT IS ENCLOSED IN CONSTRUCTION. THE MOISTURE CONTENT NEEDS TO BE CERTIFIED BY ONE OF 3 METHODS SPECIFIED. BUILDING MATERIALS WITH VISIBLE SIGNS OF WATER DAMAGE SHOULD NOT BE USED IN CONSTRUCTION. THE MOISTURE CONTENT MUST BE DETERMINED BY THE CONTRACTOR BY ONE OF THE METHODS LISTED IN CGC SECTION 4.505.3 13.BATHROOM FANS SHALL BE ENERGY STAR RATED, VENTED DIRECTLY TO THE OUTSIDE AND CONTROLLED BY A HUMIDISTAT. CGC 4.506.1 14.IF PROVIDED, WHOLE HOUSE EXHAUST FANS SHALL HAVE INSULATED COVERS OR LOUVERS WHICH CLOSE THE FAN IS OFF. THE COVERS OR LOUVERS SHALL HAVE MINIMUM R4.2 INSULATION. CGC 5.507.1 15.PROVIDE NON-REMOVABLE BACKFLOW PREVENTION DEVICES AT ALL EXTERIOR HOSE BIBS. PER CPC. 16.PROVIDE PRESSURE RELIEF VALVE WITH DRAIN TO OUTSIDE AT WATER HEATERS. PER CPC. 17.HEATING AND AC SHALL BE SIZED AND SELECTED BY ACCA MANUAL J OR ASHRAE HANDBOOK OR EQUIVALENT. THE DUCT SHALL BE SIZED IN ACCORDANCE WIHT ONE OF THE ACCA METHODS LISTED IN CGC SECTION 4.507.2 18.PRIOR TO FINAL APPROVAL OF THE BUILDING LICENSED CONTRACTOR, ARCHITECT OR ENGINEER IN RESPOSIBLE CHARGE OF THE OVERALL CONSTRUCTION MUST COMPLETE AND SIGN THE GREEN BUILDING STANDARDS CERTIFICATION FORM AND GIVEN TO THE BUILDING DEPARTMENT OFFICAL TO BE FILED WITH THE APPROVED PLANS. 19.PROVIDE FIRE BLOCKS AND DRAFT STOPS IN THE WOOD FRAME FLOOR CONSTRUCTION CONTAINING CONCEALED SPACE WHERE THERE IS USABLE SPACE ABOVE AND BELOW THE CONCEALED SPACE. SUCH DRAFT STOPS SHOULD BE INSTALLED SO THAT THE AREA OF THE CONCEALED SPACE DOES NOT EXCEED 1000 SQ. FT. DRAFTSTOPPING SHOULD DIVIDE THE CONCEALED SPACE INTO APPROXIMATELY EQUAL AREAS. PER CBC. 18 DIRECT VENT TERMINATION CAP 19A PREFABRICATED METAL FIREPLACE: BY:"ORTAL" MODEL ORTAL MINIMAL 130 TRADITIONAL 42" GAS ONLY DIRECT VENT OR APPROVED EQUAL. INSTALL IN ACCORDANCE WITH THE MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS, AND APPLICABLE CODES ANSI Z21.88/CSA 2.33a 19B PREFABRICATED METAL FIREPLACE: BY:"MAJESTIC" MODEL ODCOUG-36 MAJESTIC COURTYARD 36 GAS ONLY OUTDOOR VENT-FREE OR APPROVED EQ. INSTALL IN ACCORDANCE WITH THE MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS, AND APPLICABLE CODES. ANSI Z221.97-2014, CSA 2.41-2014 19C PREFABRICATED MODULAR FIREPLACE: BY: "ISOKERN" MODEL 42" STANDARD GAS BURNING FIREBOX OR APPROVED EQUAL INSTALL IN ACCORDANCE WITH THE MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS, AND APPLICABLE CODES. ICC REPORT NO. ESR-2316 20 FIREPLACE HEARTH 21 STONE VENEER 22 STONE TRIM 23 EXTERIOR FINISH OPENING 24 FLAT DRYWALL OPENING 25 FLAT CASED OPENING 26 3" THICK WOOD SHELVES 27 DECORATIVE WOOD BEAMS 28 SOLID SURFACE COUNTER TOP 29 HANDRAIL ONE HOUR CONSTRUCTION LOW WALL 2 X 6 STUD WALL 2 X 4 STUD WALL 2 X 8 STUD WALL 30 GUARDRAIL 31 LOW WALL 32 LOW LINEN 33 LINE OF STAIR 34 SHELF AND POLE 35 DOUBLE SHELF AND POLE 36 LAVATORY 36B PEDESTAL SINK 37 FREE STANDING TUB 38 MUDSET CERAMIC TILE SEAT 39 HOT MOPPED SHOWER PAN WITH MUDSET CERAMIC TILED WAINSCOT TO 84" AFF W/ PRESSURE BALANCE THERMOSTATIC MIXING VALVE 40 BUILT-IN SOAP NICHE 41 TEMPERED GLASS SHOWER DOOR 42 TUB / SHOWER WITH MUDSET CERAMIC TILED WAINSCOT WITH PRESSURE BALANCE THERMOSTATIC MIXING VALVE 43 MEDICINE CABINET 44 WATER CLOSET TO BE 30" MIN WIDE WITH 24" IN FRONT OF TOILET. LOW FLUSH TOILETS 1.28 GALLONS PER FLUSH 45 BAR SINK 46 LAUNDRY SINK 47 WASHER SPACE. PROVIDE RECESSED HOT AND COLD WATER BIBBS, PROVIDE FLOOR DRAIN. 48 DRYER SPACE. PROVIDE DRYER VENT TO OUTSIDE AIR PER CMC 49 INSTANTANEOUS TANKLESS WATER HEATER .94 EF / 199,000 Btu/hr 50 MECHANICAL EQUIPMENT 51 TRENCH DRAIN 52 ATTIC ACCESS 53 ROOF ACCESS 54 LINE OF FLOOR ABOVE 55 FLOOR DRAIN 56 ROOF DRAIN 57 STUCCO OVER CMU WALL REFER TO LANDSCAPE PLANS 58 42" HIGH MINIMUM GUARDRAIL WALL 59 STUCCO OVER WOOD FRAMED MECHANICAL SCREEN WALL 60 BUILT-UP ROOFING AT MECHANICAL WELL 61 ROOF MOUNTED AC UNIT REFER TO MECHANICAL PLANS 62 STONE PAVER OVER CONCRETE SLAB BASE REFER TO CIVIL AND LANDSCAPE PLANS 63 IPE WOOD LANDING REFER TO LANDSCAPE PLANS 64 6' TALL IPE WOOD FENCE REFER TO LANDSCAPE PLANS 65 LINE OF STUCCO SHELF BELOW REFER TO SHEETS T24-1a & T24-1b FOR CF1R FORMS AND COMPLIANCE INFORMATION I N S U L A T I O N S C H E D U L E Construction Name Surface Type Construction Type Framing Total Cavity Winter Design R-Value U-Value Garage Roof Volume Ceilings Wood Framed Ceiling 2x4 @ 16" o/c None 0.332 Garage Exterior Wall Exterior Walls Wood Framed Wall 2x6 @ 16" o/c None 0.347 R-30 Roof Volume Ceilings Wood Framed Ceiling 2x10 @ 16" o/c R-30 0.036 R-22 Roof Volume Ceilings Wood Framed Ceiling 2x4 @ 16" o/c R-22 0.056 R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16" o/c R-21 0.069 R-21 Wall 1 Interior Walls Wood Framed Wall 2x6 @ 16" o/c R-21 0.064 Attic / Roof / Zone 2 Attic Roofs Wood Framed Ceiling 2x4 Truss @ 24" o/c R-30 0.040 R-30 Roof HPA Ceilings Below Attic Wood Framed Ceiling 2x6 @ 24" o/c None 0.478 R-30 Floor Exterior Floors Wood Framed Floor 2x10 @ 24" o/c R-30 0.033No Crawlspace R-19 Floor No Crawlspace Interior Floors Wood Framed Floor 2x6 @ 16" o/c R-19 0.049 NOTE:BUILDING SETBACK DIMENSION IS TO FACE OF FINISH MATERIAL RIDGE VALLEY Top of Rail El 41.25' Top of Ridge El 46.25' A/C WELL B RI D G E Roof V V Dn 10R N52 46'30"E 79.46' N3 9 5 3 ' 3 0 " W 2 5 . 0 3 ' N3 9 3 5 ' 3 0 " W 2 5 . 0 2 ' LOT 3 N52 46'30"E 79.33' Se a s h o r e D r i v e VA L L E Y Strip Drain Deck RI D G E 3:12 3:12 3: 1 2 3: 1 2 3:12 3:12 3:12 3: 1 2 3: 1 2 3: 1 2 Roof Plan SCALE: 1/4" = 1'-0" ROOF PLAN PLOT REFERENCE DATE: 03-29-23 SHEET NUMBER: 503 32ND STREET, SUITE 130 TELEPHONE: (949) 584-8987 NEWPORT BEACH, CA 92663 Email: ritnergroup.com STAMP: TELEPHONE: FAX: A3.1 SHEET TITLE: ‹RITNER GROUP, INC. 2023 expressly reserves all common law copyright and property rights in these plans. These plans are not to be reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party without first obtaining the express written permission and consent of RITNER GROUP, INC. PROJECT DESIGNER: PROJECT CAD FILE: PROJECT NUMBER: DRAWN BY: PROJECT MANAGER: 22012-FLOOR O: \ 2 0 2 2 - P R O J E C T S \ 2 2 0 1 2 \ C D \ 2 2 0 1 2 - F L O O R Ma r c h 2 9 , 2 0 2 3 BG RR 22012 Lot 4, Block 39 Pr o g r e s s S e t / 0 3 - 2 9 - 2 3 PROJECT: BUILDING DEPARTMENT SUBMITTAL: - REVISIONS: --- ROOF LEGENDROOF KEY NOTES 1 SLATE TILE "FAIRWEATHER WAY" ICC ESR- TABLE 1 WEIGHT 11.0 (psf) CLASS "A" OVER UNDERLAYMENT BY: AMERICAN SLATE OR APPROVED EQUAL INSTALL PER MANUFACTURER SPECIFICATIONS 2 BUILT-UP (CLASS "A") MODIFIED BITUMEN ROOFING OVER EXTERIOR GRADE ROOF SHEATHING 1/4" : 12" MINIMUM SLOPE U.N.O. 3 STONE PAVING OVER DEX-O-TEX WEATHERWEAR ROOF AND DECK COVERING ICC ESR REPORT 1757 INSTALL PER MANUFACTURER SPECIFICATIONS 4 LINE OF BUILDING BELOW 5 LINE OF COUNTER BELOW 6 LINE OF BALCONY BELOW 7 LINE OF ROOF BELOW 8 26 GA GALV METAL SADDLE AT CHIMNEY 9 CHIMNEY CAP, REFER TO DETAIL 22 /D1.1 SYMBOLXX DS INDICATES ROOF PITCH AND DIRECTION OF ROOF SLOPE INDICATES LOCATION OF METAL DOWNSPOUT. ROOF PLAN NOTES x : 121.CONTRACTOR SHALL VERIFY AREA OF ALL ATTIC VENTS WITH MANUFACTURER. 2.ALL ROOF SHEATHING EDGES SHALL BE BLOCKED AND NAILED PER STRUCTURAL PLANS. IN ADDITION, CONTRACTOR SHALL ALSO PROVIDE MIN. BLOCKING AND NAILING AS REQUIRED BY THE ROOFING MFR. 3.PROVIDE CLASS A ROOF WITH FIRE STOP TO PREVENT INTRUSION OF FLAMES AND EMBERS OR 1 LAYER OF No. 72 ASTM CAP SHEET 4.PROVIDE NOT LESS THAN 26 GA. GALV. FLASHING OVER No. 72 ASTM CAP SHEET. 5.ROOF GUTTERS SHALL BE PROVIDED WITH THE MEANS TO PREVENT ACCUMULATION OF LEAVES AND DEBRIS. CBC 705A.4 6.ATTIC VENTS SHALL MEET THE FOLLOWING REQUIREMENTS, CBC 1203. 7.OPENINGS SHALL HAVE CORROSION RESISTANT WIRE MESH OR OTHER APPROVED MATERIAL WITH 1 8" MINIMUM AND 1 4" MAXIMUM OPENING. 8.50% OF THE REQUIRED VENTILATION AREA MUST BE LOCATED AT LEAST 3 FOOT ABOVE EAVE OR CORNICE VENTS WITH THE BALANCE PROVIDED BY EAVE OR CORNICE VENTS. 10 DECORATIVE CAP 11 COPPER METAL GUTTER TYPICAL 12 COPPER METAL DOWNSPOUT TYPICAL 13 ROOF DRAIN & OVERFLOW BY: THUNDERBIRD PRODUCTS, INC. SEE DETAIL 4 / D1.2 ICC - ES REPORT PMG-1212 CONNECTED TO SITE DRAINAGE SYSTEM OVERFLOW TO BE PIPED SEPARATELY R903.4.1 14 DECK DRAIN PER DETAIL 12 / D4.3 BY:THUNDERBIRD PRODUCTS, INC ICC - ES REPORT PMG-1212 CONNECTED TO DRAINAGE SYSTEM 15 RECESSED DECK STRIP DRAIN PER DETAIL 5 / D4.2 CONNECTED TO DRAINAGE SYSTEM 16 PARAPET 17 CLOAKED VENT TILES BY:"OHAGIN'S MANUFACTURING, LLC" ICC-ES-REPORT SBCCI-9650A 18 BALCONY RAILING 19 EXPOSED WOOD ROOF FRAMING 20 BUILT-UP CRICKET 2% MIN 21 MANUFACTURED ALUMINUM 30" X 36" ROOF HATCH BY:"BABCOCK - DAVIS" MODEL # BA-3630 22 ROOF MOUNTED COMPACT AC UNIT REFER TO MECHANICAL PLANS & SPECIFICATIONS INDICATES O'HAGIN'S CLOAKED VENT STANDARD LINE FOR COMPOSITION SHINGLES OR APPROVED EQUAL. ICC-ES REPORT SBCII-9650A NET FREE AREA 72 SQ. IN. HATCHING INDICATES SOLAR READY ROOFING AREA TOTAL =144 SQ. IN. SQ. IN.144SQ. IN. EA. =72DORMER VENT - LOW PROFILE SQ. FT. / =300 X 144 = VENTILATION REQUIRED: ATTIC AREA = VENTILATION PROVIDED: (2) 243 ATTIC AREA: 1 .81 117 SQ. FT. SQ. IN. TOTAL =72 SQ. IN. SQ. IN.72SQ. IN. EA. =72DORMER VENT - LOW PROFILE SQ. FT. / =300 X 144 = VENTILATION REQUIRED: ATTIC AREA = VENTILATION PROVIDED: (1) 106 ATTIC AREA: 2 .35 51 SQ. FT. SQ. IN. BY: O'HAGIN'S INC OR APPROVED EQUAL BY: O'HAGIN'S INC OR APPROVED EQUAL N3 9 3 5 ' 3 0 " W 2 5 . 0 2 ' Alley Se a s h o r e D r i v e Main Level Reflected Ceiling Plan SCALE: 1/4" = 1'-0" MAIN LEVEL REFLECTED CEILING PLAN PLOT REFERENCE DATE: 03-29-23 SHEET NUMBER: 503 32ND STREET, SUITE 130 TELEPHONE: (949) 584-8987 NEWPORT BEACH, CA 92663 Email: ritnergroup.com STAMP: TELEPHONE: FAX: A8.1 SHEET TITLE: ‹RITNER GROUP, INC. 2023 expressly reserves all common law copyright and property rights in these plans. These plans are not to be reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party without first obtaining the express written permission and consent of RITNER GROUP, INC. PROJECT DESIGNER: PROJECT CAD FILE: PROJECT NUMBER: DRAWN BY: PROJECT MANAGER: 22012-FLOOR O: \ 2 0 2 2 - P R O J E C T S \ 2 2 0 1 2 \ C D \ 2 2 0 1 2 - F L O O R Ma r c h 2 9 , 2 0 2 3 BG RR 22012 Lot 4, Block 39 Pr o g r e s s S e t / 0 3 - 2 9 - 2 3 PROJECT: BUILDING DEPARTMENT SUBMITTAL: - REVISIONS: --- REFLECTED CEILING PLAN KEY NOTES SYMBOLXX 1 DRYWALL CEILING 2 PLASTER FINISH CEILING 3 T&G SHEATHING 4 T&G ROOF SHEATHING 5 EXPOSED RAFTER TAIL 6 EXPOSED BEAMS AND RAFTERS 7 APPLIED WOOD BEAM 8 DOOR OPENING 9 WINDOW OPENING 10 GARAGE DOOR OPENING 11 FIREPLACE OPENING 12 DRYWALL OPENING 13 CASED OPENING 14 PLASTER OPENING 15 ATTIC ACCESS 16 ROOF HATCH 17 EXPOSED TRELLIS 18 LIGHT FIXTURE REFER TO ELECTRICAL PLANS 19 SMOKE DETECTOR REFER TO ELECTRICAL PLANS 20 MECHANICAL REGISTER REFER TO MECHANICAL PLANS 21 MECHANICAL FAN REFER TO MECHANICAL 22 LINE OF FLOOR ABOVE 23 LINE OF FIREPLACE ABOVE 24 LINE OF ROOF ABOVE 25 LINE OF BALCONY RAIL 26 PLASTER SOFFIT 27 LINE OF FACE FRAME CABINET 28 RECESSED CEILING MOUNTED ELECTRIC HEATER UNIT N3 9 3 5 ' 3 0 " W 2 5 . 0 2 ' Alley Se a s h o r e D r i v e N3 9 3 5 ' 3 0 " W 2 5 . 0 2 ' Alley Se a s h o r e D r i v e Second Level Reflected Ceiling Plan SCALE: 1/4" = 1'-0" SECOND & THIRD LEVEL REFLECTED CEILING PLANS PLOT REFERENCE DATE: 03-29-23 SHEET NUMBER: 503 32ND STREET, SUITE 130 TELEPHONE: (949) 584-8987 NEWPORT BEACH, CA 92663 Email: ritnergroup.com STAMP: TELEPHONE: FAX: A8.2 SHEET TITLE: ‹RITNER GROUP, INC. 2023 expressly reserves all common law copyright and property rights in these plans. These plans are not to be reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party without first obtaining the express written permission and consent of RITNER GROUP, INC. PROJECT DESIGNER: PROJECT CAD FILE: PROJECT NUMBER: DRAWN BY: PROJECT MANAGER: 22012-FLOOR O: \ 2 0 2 2 - P R O J E C T S \ 2 2 0 1 2 \ C D \ 2 2 0 1 2 - F L O O R Ma r c h 2 9 , 2 0 2 3 BG RR 22012 Lot 4, Block 39 Pr o g r e s s S e t / 0 3 - 2 9 - 2 3 PROJECT: BUILDING DEPARTMENT SUBMITTAL: - REVISIONS: --- REFLECTED CEILING PLAN KEY NOTES SYMBOLXX 1 DRYWALL CEILING 2 PLASTER FINISH CEILING 3 T&G SHEATHING 4 T&G ROOF SHEATHING 5 EXPOSED RAFTER TAIL 6 EXPOSED BEAMS AND RAFTERS 7 APPLIED WOOD BEAM 8 DOOR OPENING 9 WINDOW OPENING 10 GARAGE DOOR OPENING 11 FIREPLACE OPENING 12 DRYWALL OPENING 13 CASED OPENING 14 PLASTER OPENING 15 ATTIC ACCESS 16 ROOF HATCH 17 EXPOSED TRELLIS 18 LIGHT FIXTURE REFER TO ELECTRICAL PLANS 19 SMOKE DETECTOR REFER TO ELECTRICAL PLANS 20 MECHANICAL REGISTER REFER TO MECHANICAL PLANS 21 MECHANICAL FAN REFER TO MECHANICAL 22 LINE OF FLOOR ABOVE 23 LINE OF FIREPLACE ABOVE 24 LINE OF ROOF ABOVE 25 LINE OF BALCONY RAIL 26 PLASTER SOFFIT 27 LINE OF FACE FRAME CABINET 28 RECESSED CEILING MOUNTED ELECTRIC HEATER UNIT Third Level Reflected Ceiling Plan SCALE: 1/4" = 1'-0" 7' - 1 " Ba 2 10 3 4" T.Pl. EL. 28.01 1' - 1 " T.Pl. EL. 18.93 Master Suite T.O.Shtg. EL. 37.54 8' - 0 " 7' - 0 " Garage T.O.Shtg. EL. 20.01 T.O.Shtg. EL. 28.90 T.O.Railing EL. 41.25 3' - 8 " HP of Garage EL. 11.85 1' - 7 3 4" W / D 6' - 4 1 2" Bedroom 2 B.O.Hdr. EL. 35.28 T.Pl. EL. 35.90 7' - 0 3 4" 3 12 SetbackSetback T.O.Slab EL. 17.25 Maximum Height EL.46.25 3'-0"3'-0" 8' - 0 " T.O.Shtg. EL. 28.90 T.O.Shtg. EL. 20.01 10 3 4" 7' - 0 " 1' - 7 3 4" 1' - 1 " 6' - 4 1 2" T.Pl. EL. 18.93 T.Pl. EL. 28.01 T.O.Railing EL. 41.25 H.P.of Garage EL. 11.85 7' - 1 " 3' - 8 " T.O.Shtg. EL. 37.54 Living Room Carport B.O.Hdr. EL. 35.28 T.Pl. EL. 35.90 T.O.Slab EL. 17.25 Maximum Height EL.46.25 3'-0"3'-0" SetbackSetback 3 T.Pl. EL. 26.16 Maximum Height EL.46.25 T.Pl. EL. 35.32 B.O.Slab EL. 16.00 T.Pl. EL. 44.02 T.O.Slab EL. 17.25 8'- 1 " T.O. Sheathing EL.36.40 B.O.Hdr. EL. 43.46 7' - 0 3 4" 8'- 1 1 " 7' - 7 1 2" T.O.Shtg. EL. 27.24 12 9' - 0 " T.O.Slab EL. 17.25 Maximum Height EL.46.25 29 ' - 0 " 3'-0" Setback 3'-0" Setback Section "B"SCALE: 1/4" = 1'-0" BUILDING SECTIONS PLOT REFERENCE DATE: 03-22-23 SHEET NUMBER: 503 32ND STREET, SUITE 130 TELEPHONE: (949) 584-8987 NEWPORT BEACH, CA 92663 Email: ritnergroup.com STAMP: TELEPHONE: FAX: A4.1 SHEET TITLE: ‹RITNER GROUP, INC. 2023 expressly reserves all common law copyright and property rights in these plans. These plans are not to be reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party without first obtaining the express written permission and consent of RITNER GROUP, INC. PROJECT DESIGNER: PROJECT CAD FILE: PROJECT NUMBER: DRAWN BY: PROJECT MANAGER: 22012-ELEV O: \ 2 0 2 2 - P R O J E C T S \ 2 2 0 1 2 \ C D \ 2 2 0 1 2 - E L E V Ma r c h 2 9 , 2 0 2 3 BG RR 22012 Lot 4, Block 39 Pr o g r e s s S e t / 0 3 - 2 2 - 2 3 PROJECT: BUILDING DEPARTMENT SUBMITTAL: - REVISIONS: --- Section "A"SCALE: 1/4" = 1'-0"Section "C"SCALE: 1/4" = 1'-0" 1.REFER TO STRUCTURAL ENGINEER DRAWINGS. 2.DETAILS REFERENCED IN THESE DRAWINGS ARE FOR CLARIFICATION OF THE ARCHITECTURAL DESIGN INTENT. REFER TO ENGINEERING DRAWINGS PREPARED BY OTHERS FOR DETAILED INFORMATION. 3. UPPER FLOOR DIMENSIONS ARE TAKEN FROM TOP OF SUB FLOOR SHEATHING MATERIAL. SECTION NOTES SECTION KEY NOTES 1.TYPICAL ROOF ASSEMBLY: A:STANDING SEAM METAL ROOF BY: CUSTOM BILT METALS B:RATED UL-580 CLASS 90 C:TABLE 1 TILE WEIGHT - psf D:UNDERLAYMENT E:PLYWOOD SHEETING MATERIAL GLUED AND SCREWED . THICKNESS PER STRUCTURAL ENGINEER 2.TYPICAL FLOOR / CEILING ASSEMBLY A:FLOOR FINISH : SEE PLAN B:GYPCRETE C:SUBFLOOR SHEATHING MATERIAL GLUED AND SCREWED THICKNESS PER STRUCTURAL ENGINEER D:FLOOR JOISTS PER STRUCTURAL ENGINEER E:2x WOOD FURRING (WHERE OCCURS). F:5/8" GYPSUM WALLBOARD ( TYPE "X" WHERE REQUIRED) 3.TYPICAL DECK / CEILING ASSEMBLY A:STONE PAVERS OVER FULL MORTAR BED B:SLOPED EPS DECK SYSTEM C:ELASTOMERIC SHEET WATERPROOFING D:SUBFLOOR SHEATHING MATERIAL GLUED AND SCREWED THICKNESS PER STRUCTURAL ENGINEER E:DECK JOIST PER STRUCTURAL ENGINEER 4.TYPICAL EXTERIOR WALL ASSEMBLY A:HARDBOARD SIDING BY "JAMES HARDIE" OR EQUAL B:BRICK VENEER WHERE OCCURS C:WIRE LATH OVER MIN. 2 LAYERS GRADE "D" BUILDING PAPER D:PLYWOOD SHEATHING OR SHEAR PANELS WHERE INDICATED ON STRUCTURAL PLANS E:2x WALL FRAMING WITH INSULATION PER TITLE 24 CALCULATIONS F:5/8" GYPSUM WALLBOARD (TYPE "X" WHERE REQUIRED) 5.TYPICAL INTERIOR WALL ASSEMBLY A:5/8" GYPSUM WALLBOARD (TYPE "X" WHERE REQUIRED) EACH SIDE B:2x WOOD FRAMING PER STRUCTURAL PLANS 6.TYPICAL STAIR ASSEMBLY A:CONTINUOUS HANDRAIL SECURELY FASTENED TO WALL AT 36" MAXIMUM AND 34" MINIMUM ABOVE TREAD AT NOSING B:FINISH MATERIAL PER PLAN C:5/8" THICK RISERS D:1 1/8" THICK TREADS E:MINIMUM (3) 2 x 12 STRINGERS AT STRAIGHT RUN F:(1) 2 x 8 AT FRONT AND BACK OF TREADS AT RADIAL RUN G:2 x 8 JOISTS AT 16" O.C. MINIMUM AT LANDING. REFER TO STRUCTURAL DRAWINGS H:POSITIVE CONNECTION TO FLOOR. REFER TO STRUCTURAL PLANS FOR CONNECTION. I:5/8" GYPSUM BOARD (TYPE "X" WHERE REQUIRED) AT WALLS AND CEILINGS OF ALL USABLE AREA UNDER STAIR SYMBOLX 7A CONCRETE SLAB. SEE STRUCTURAL DWGS. 7B RAISED CONCRETE SLAB 7C CONCRETE STEM WALL 7D CONCRETE GRADE BEAM 7E CONCRETE CAISSON 8 2x WOOD FRAMING 9 WOOD I-JOISTS. SEE STRUCTURAL DWGS 10 WOOD CONVENTIONAL FRAMED ROOF. SEE STRUCTURAL DRAWINGS. 11 2x CEILING JOIST 12 PLYWOOD ROOF SHEATHING. SEE STRUCT. DWGS. RADIANT BARRIER TO BE INSTALLED PER TITLE 24, REFER TO SHEET T-24.MM FOR INSTALLATION METHODS 13 2 x T&G FLOOR SHEATHING 14 STEEL BEAMS WRAPPED IN WOOD 15 EXPOSED RAFTER TAIL 16 INSULATION, SEE TITLE 24 17 RIGID INSULATION 18 COPPER GUTTER / DOWNSPOUT 19 WOOD GUARDRAIL DETAILING WITH HORIZONTAL STAINLESS STEEL CABLE RAILING - PER DETAIL 12 / D4.2 20 WOOD SIDING 21 WOOD DETAILING 22 WOOD CEILING / SOFFIT / FALSE CEILING BEAMS REFER TO REFLECTED CEILING PLANS 23 DRYWALL CEILING / SOFFIT REFER TO REFLECTED CEILING PLANS TYPICAL 24 WOOD DOORS & WINDOWS 25 SOLID SURFACE STONE TOP 26 STONE TILE WALL CAP 27 BRICK VENEER 28 BUILT - IN CABINETRY REFER TO SHEETS T24-1a & T24-1b FOR CF1R FORMS AND COMPLIANCE INFORMATION I N S U L A T I O N S C H E D U L E Construction Name Surface Type Construction Type Framing Total Cavity Winter Design R-Value U-Value Garage Roof Volume Ceilings Wood Framed Ceiling 2x4 @ 16" o/c None 0.332 Garage Exterior Wall Exterior Walls Wood Framed Wall 2x6 @ 16" o/c None 0.347 R-30 Roof Volume Ceilings Wood Framed Ceiling 2x10 @ 16" o/c R-30 0.036 R-22 Roof Volume Ceilings Wood Framed Ceiling 2x4 @ 16" o/c R-22 0.056 R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16" o/c R-21 0.069 R-21 Wall 1 Interior Walls Wood Framed Wall 2x6 @ 16" o/c R-21 0.064 Attic / Roof / Zone 2 Attic Roofs Wood Framed Ceiling 2x4 Truss @ 24" o/c R-30 0.040 R-30 Roof HPA Ceilings Below Attic Wood Framed Ceiling 2x6 @ 24" o/c None 0.478 R-30 Floor Exterior Floors Wood Framed Floor 2x10 @ 24" o/c R-30 0.033No Crawlspace R-19 Floor No Crawlspace Interior Floors Wood Framed Floor 2x6 @ 16" o/c R-19 0.049 NOTE:BUILDING SETBACK DIMENSION IS TO FACE OF FINISH MATERIALNOTE:BUILDING SETBACK DIMENSION IS TO FACE OF FINISH MATERIAL NOTE:BUILDING SETBACK DIMENSION IS TO FACE OF FINISH MATERIAL 8' - 1 " T.O. Sheathing EL.36.40 8' - 1 1 " T.O.Slab EL. 17.25 T.Pl. EL. 35.32 T.Pl. EL. 26.16 T.O.Shtg. EL. 27.24 Max Height EL.46.25 B.O.Slab EL. 16.00 B.O.Hdr. EL. 43.46 7' - 0 3 4" T.Pl. EL. 44.02 7' - 7 1 2" Living Master Suite 3'-0"3'-0" Setback Setback 29 ' - 0 " Office Ba 2Bedroom 2 Entry B.O.Hdr. EL. 43.07 T.Pl. EL. 26.16 8' - 1 1 " 6' - 8 " T.O.Slab EL. 17.25 8'- 1 " Maximum Height EL.46.25 7'- 5 1 2" T.O. Sheathing EL.36.40 B.O.Slab EL. 16.00 T.Pl. EL. 35.32 Porch T.Pl. EL. 43.86 T.O.Shtg. EL. 27.24 8'- 0 3 4"Kitchen 3 12 3'-0" T.O.Slab EL. 17.25 Maximum Height EL.46.25 3'-0" SetbackSetback BUILDING SECTIONS PLOT REFERENCE DATE: 03-22-23 SHEET NUMBER: 503 32ND STREET, SUITE 130 TELEPHONE: (949) 584-8987 NEWPORT BEACH, CA 92663 Email: ritnergroup.com STAMP: TELEPHONE: FAX: A4.2 SHEET TITLE: ‹RITNER GROUP, INC. 2023 expressly reserves all common law copyright and property rights in these plans. These plans are not to be reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party without first obtaining the express written permission and consent of RITNER GROUP, INC. PROJECT DESIGNER: PROJECT CAD FILE: PROJECT NUMBER: DRAWN BY: PROJECT MANAGER: 22012-ELEV O: \ 2 0 2 2 - P R O J E C T S \ 2 2 0 1 2 \ C D \ 2 2 0 1 2 - E L E V Ma r c h 2 9 , 2 0 2 3 BG RR 22012 Lot 4, Block 39 Pr o g r e s s S e t / 0 3 - 2 2 - 2 3 PROJECT: BUILDING DEPARTMENT SUBMITTAL: - REVISIONS: --- Section "D"SCALE: 1/4" = 1'-0" Section "F"SCALE: 1/4" = 1'-0" 1.REFER TO STRUCTURAL ENGINEER DRAWINGS. 2.DETAILS REFERENCED IN THESE DRAWINGS ARE FOR CLARIFICATION OF THE ARCHITECTURAL DESIGN INTENT. REFER TO ENGINEERING DRAWINGS PREPARED BY OTHERS FOR DETAILED INFORMATION. 3. UPPER FLOOR DIMENSIONS ARE TAKEN FROM TOP OF SUB FLOOR SHEATHING MATERIAL. SECTION NOTES SECTION KEY NOTES 1.TYPICAL ROOF ASSEMBLY: A:STANDING SEAM METAL ROOF BY: CUSTOM BILT METALS B:RATED UL-580 CLASS 90 C:TABLE 1 TILE WEIGHT - psf D:UNDERLAYMENT E:PLYWOOD SHEETING MATERIAL GLUED AND SCREWED . THICKNESS PER STRUCTURAL ENGINEER 2.TYPICAL FLOOR / CEILING ASSEMBLY A:FLOOR FINISH : SEE PLAN B:GYPCRETE C:SUBFLOOR SHEATHING MATERIAL GLUED AND SCREWED THICKNESS PER STRUCTURAL ENGINEER D:FLOOR JOISTS PER STRUCTURAL ENGINEER E:2x WOOD FURRING (WHERE OCCURS). F:5/8" GYPSUM WALLBOARD ( TYPE "X" WHERE REQUIRED) 3.TYPICAL DECK / CEILING ASSEMBLY A:STONE PAVERS OVER FULL MORTAR BED B:SLOPED EPS DECK SYSTEM C:ELASTOMERIC SHEET WATERPROOFING D:SUBFLOOR SHEATHING MATERIAL GLUED AND SCREWED THICKNESS PER STRUCTURAL ENGINEER E:DECK JOIST PER STRUCTURAL ENGINEER 4.TYPICAL EXTERIOR WALL ASSEMBLY A:HARDBOARD SIDING BY "JAMES HARDIE" OR EQUAL B:BRICK VENEER WHERE OCCURS C:WIRE LATH OVER MIN. 2 LAYERS GRADE "D" BUILDING PAPER D:PLYWOOD SHEATHING OR SHEAR PANELS WHERE INDICATED ON STRUCTURAL PLANS E:2x WALL FRAMING WITH INSULATION PER TITLE 24 CALCULATIONS F:5/8" GYPSUM WALLBOARD (TYPE "X" WHERE REQUIRED) 5.TYPICAL INTERIOR WALL ASSEMBLY A:5/8" GYPSUM WALLBOARD (TYPE "X" WHERE REQUIRED) EACH SIDE B:2x WOOD FRAMING PER STRUCTURAL PLANS 6.TYPICAL STAIR ASSEMBLY A:CONTINUOUS HANDRAIL SECURELY FASTENED TO WALL AT 36" MAXIMUM AND 34" MINIMUM ABOVE TREAD AT NOSING B:FINISH MATERIAL PER PLAN C:5/8" THICK RISERS D:1 1/8" THICK TREADS E:MINIMUM (3) 2 x 12 STRINGERS AT STRAIGHT RUN F:(1) 2 x 8 AT FRONT AND BACK OF TREADS AT RADIAL RUN G:2 x 8 JOISTS AT 16" O.C. MINIMUM AT LANDING. REFER TO STRUCTURAL DRAWINGS H:POSITIVE CONNECTION TO FLOOR. REFER TO STRUCTURAL PLANS FOR CONNECTION. I:5/8" GYPSUM BOARD (TYPE "X" WHERE REQUIRED) AT WALLS AND CEILINGS OF ALL USABLE AREA UNDER STAIR SYMBOLX 7A CONCRETE SLAB. SEE STRUCTURAL DWGS. 7B RAISED CONCRETE SLAB 7C CONCRETE STEM WALL 7D CONCRETE GRADE BEAM 7E CONCRETE CAISSON 8 2x WOOD FRAMING 9 WOOD I-JOISTS. SEE STRUCTURAL DWGS 10 WOOD CONVENTIONAL FRAMED ROOF. SEE STRUCTURAL DRAWINGS. 11 2x CEILING JOIST 12 PLYWOOD ROOF SHEATHING. SEE STRUCT. DWGS. RADIANT BARRIER TO BE INSTALLED PER TITLE 24, REFER TO SHEET T-24.MM FOR INSTALLATION METHODS 13 2 x T&G FLOOR SHEATHING 14 STEEL BEAMS WRAPPED IN WOOD 15 EXPOSED RAFTER TAIL 16 INSULATION, SEE TITLE 24 17 RIGID INSULATION 18 COPPER GUTTER / DOWNSPOUT 19 WOOD GUARDRAIL DETAILING WITH HORIZONTAL STAINLESS STEEL CABLE RAILING - PER DETAIL 12 / D4.2 20 WOOD SIDING 21 WOOD DETAILING 22 WOOD CEILING / SOFFIT / FALSE CEILING BEAMS REFER TO REFLECTED CEILING PLANS 23 DRYWALL CEILING / SOFFIT REFER TO REFLECTED CEILING PLANS TYPICAL 24 WOOD DOORS & WINDOWS 25 SOLID SURFACE STONE TOP 26 STONE TILE WALL CAP 27 BRICK VENEER 28 BUILT - IN CABINETRY REFER TO SHEETS T24-1a & T24-1b FOR CF1R FORMS AND COMPLIANCE INFORMATION I N S U L A T I O N S C H E D U L E Construction Name Surface Type Construction Type Framing Total Cavity Winter Design R-Value U-Value Garage Roof Volume Ceilings Wood Framed Ceiling 2x4 @ 16" o/c None 0.332 Garage Exterior Wall Exterior Walls Wood Framed Wall 2x6 @ 16" o/c None 0.347 R-30 Roof Volume Ceilings Wood Framed Ceiling 2x10 @ 16" o/c R-30 0.036 R-22 Roof Volume Ceilings Wood Framed Ceiling 2x4 @ 16" o/c R-22 0.056 R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16" o/c R-21 0.069 R-21 Wall 1 Interior Walls Wood Framed Wall 2x6 @ 16" o/c R-21 0.064 Attic / Roof / Zone 2 Attic Roofs Wood Framed Ceiling 2x4 Truss @ 24" o/c R-30 0.040 R-30 Roof HPA Ceilings Below Attic Wood Framed Ceiling 2x6 @ 24" o/c None 0.478 R-30 Floor Exterior Floors Wood Framed Floor 2x10 @ 24" o/c R-30 0.033No Crawlspace R-19 Floor No Crawlspace Interior Floors Wood Framed Floor 2x6 @ 16" o/c R-19 0.049 NOTE:BUILDING SETBACK DIMENSION IS TO FACE OF FINISH MATERIAL NOTE:BUILDING SETBACK DIMENSION IS TO FACE OF FINISH MATERIAL T.O.Shtg. EL. 20.01 T.Pl. EL. 44.02 H.P.of Garage EL. 11.85 T.O. Sheathing EL.36.40 8' - 1 " 8' - 1 1 " T.Pl. EL. 35.32 T.O.Slab EL. 25.31 T.O.Shtg. EL. 27.24 Maximum Height EL.46.25 B.O.Slab EL. 16.00 T.Pl. EL. 26.16 7' - 0 3 4" B.O.Hdr. EL. 43.46 T.Pl. EL. 35.90 7' - 7 1 2" T.Pl. EL. 18.93 T.Pl. EL. 28.01 7' - 1 " 8' - 0 " 1' - 1 " 7' - 0 " T.O.Shtg. EL. 28.90 1' - 7 3 4" 10 3 4" 3' - 8 " T.O.Railing EL. 41.25 T.O.Shtg. EL. 37.54 -Master Closet Master Suite Bath 2 Attic Roof Deck 8' - 0 3 4" Two-Story Living Dine Carport Garage Storage Bath 2 Storage Open Air Open Air Kitchen B.O.Hdr. EL. 27.07 B.O.Hdr. EL. 35.28 7' - 0 3 4" 6' - 4 1 2" 7' - 0 3 4" B.O.Hdr. EL. 34.30 B.O.Hdr. EL. 34.30 4' - 2 " 6' - 0 " 2'-0"3'-0" 5'-0" P L 2nd Front Setback 29 ' - 0 " P L T.O. Sheathing EL.36.40 8' - 1 " T.O.Slab EL. 17.25 T.Pl. EL. 26.16 8' - 1 1 " Maximum Height EL.46.25 B.O.Slab EL. 16.00 T.O.Shtg. EL. 27.24 T.Pl. EL. 35.32 7' - 0 3 4" 7' - 7 1 2" T.Pl. EL. 44.02 B.O.Hdr. EL. 43.46 T.Pl. EL. 18.93 T.O.Shtg. EL. 20.01 H.P.of Garage EL. 11.85 5' - 3 3 4" 7' - 1 " T.Pl. EL. 28.01 8' - 0 " 7'- 0 " 10 3 4" 1' - 1 " T.O.Railing EL. 41.25 T.O.Shtg. EL. 28.90 T.Pl. EL. 35.90 Master Bath Roof Deck Hall - Bedroom 2Master Suite Office Roof Deck Kitchen Bedroom 2 Master BathMaster Suite Garage Carport Two-Story Living B.O.Hdr. EL. 27.07 6' - 4 1 2" B.O.Hdr. EL. 35.28 7' - 0 3 4" 7'- 9 " 7' - 0 " 7' - 1 " Dine Kitchen 2'-0"3'-0" 5'-0"15'-0" P L Building Setback2nd Front Setback 29 ' - 0 " P L Section "G"SCALE: 1/4" = 1'-0" BUILDING SECTIONS PLOT REFERENCE DATE: 03-22-23 SHEET NUMBER: 503 32ND STREET, SUITE 130 TELEPHONE: (949) 584-8987 NEWPORT BEACH, CA 92663 Email: ritnergroup.com STAMP: TELEPHONE: FAX: A4.3 SHEET TITLE: ‹RITNER GROUP, INC. 2023 expressly reserves all common law copyright and property rights in these plans. These plans are not to be reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party without first obtaining the express written permission and consent of RITNER GROUP, INC. PROJECT DESIGNER: PROJECT CAD FILE: PROJECT NUMBER: DRAWN BY: PROJECT MANAGER: 22012-ELEV O: \ 2 0 2 2 - P R O J E C T S \ 2 2 0 1 2 \ C D \ 2 2 0 1 2 - E L E V Ma r c h 2 9 , 2 0 2 3 BG RR 22012 Lot 4, Block 39 Pr o g r e s s S e t / 0 3 - 2 2 - 2 3 PROJECT: BUILDING DEPARTMENT SUBMITTAL: - REVISIONS: --- Section "F"SCALE: 1/4" = 1'-0" 1.REFER TO STRUCTURAL ENGINEER DRAWINGS. 2.DETAILS REFERENCED IN THESE DRAWINGS ARE FOR CLARIFICATION OF THE ARCHITECTURAL DESIGN INTENT. REFER TO ENGINEERING DRAWINGS PREPARED BY OTHERS FOR DETAILED INFORMATION. 3. UPPER FLOOR DIMENSIONS ARE TAKEN FROM TOP OF SUB FLOOR SHEATHING MATERIAL. SECTION NOTES SECTION KEY NOTES 1.TYPICAL ROOF ASSEMBLY: A:STANDING SEAM METAL ROOF BY: CUSTOM BILT METALS B:RATED UL-580 CLASS 90 C:TABLE 1 TILE WEIGHT - psf D:UNDERLAYMENT E:PLYWOOD SHEETING MATERIAL GLUED AND SCREWED . THICKNESS PER STRUCTURAL ENGINEER 2.TYPICAL FLOOR / CEILING ASSEMBLY A:FLOOR FINISH : SEE PLAN B:GYPCRETE C:SUBFLOOR SHEATHING MATERIAL GLUED AND SCREWED THICKNESS PER STRUCTURAL ENGINEER D:FLOOR JOISTS PER STRUCTURAL ENGINEER E:2x WOOD FURRING (WHERE OCCURS). F:5/8" GYPSUM WALLBOARD ( TYPE "X" WHERE REQUIRED) 3.TYPICAL DECK / CEILING ASSEMBLY A:STONE PAVERS OVER FULL MORTAR BED B:SLOPED EPS DECK SYSTEM C:ELASTOMERIC SHEET WATERPROOFING D:SUBFLOOR SHEATHING MATERIAL GLUED AND SCREWED THICKNESS PER STRUCTURAL ENGINEER E:DECK JOIST PER STRUCTURAL ENGINEER 4.TYPICAL EXTERIOR WALL ASSEMBLY A:HARDBOARD SIDING BY "JAMES HARDIE" OR EQUAL B:BRICK VENEER WHERE OCCURS C:WIRE LATH OVER MIN. 2 LAYERS GRADE "D" BUILDING PAPER D:PLYWOOD SHEATHING OR SHEAR PANELS WHERE INDICATED ON STRUCTURAL PLANS E:2x WALL FRAMING WITH INSULATION PER TITLE 24 CALCULATIONS F:5/8" GYPSUM WALLBOARD (TYPE "X" WHERE REQUIRED) 5.TYPICAL INTERIOR WALL ASSEMBLY A:5/8" GYPSUM WALLBOARD (TYPE "X" WHERE REQUIRED) EACH SIDE B:2x WOOD FRAMING PER STRUCTURAL PLANS 6.TYPICAL STAIR ASSEMBLY A:CONTINUOUS HANDRAIL SECURELY FASTENED TO WALL AT 36" MAXIMUM AND 34" MINIMUM ABOVE TREAD AT NOSING B:FINISH MATERIAL PER PLAN C:5/8" THICK RISERS D:1 1/8" THICK TREADS E:MINIMUM (3) 2 x 12 STRINGERS AT STRAIGHT RUN F:(1) 2 x 8 AT FRONT AND BACK OF TREADS AT RADIAL RUN G:2 x 8 JOISTS AT 16" O.C. MINIMUM AT LANDING. REFER TO STRUCTURAL DRAWINGS H:POSITIVE CONNECTION TO FLOOR. REFER TO STRUCTURAL PLANS FOR CONNECTION. I:5/8" GYPSUM BOARD (TYPE "X" WHERE REQUIRED) AT WALLS AND CEILINGS OF ALL USABLE AREA UNDER STAIR SYMBOLX 7A CONCRETE SLAB. SEE STRUCTURAL DWGS. 7B RAISED CONCRETE SLAB 7C CONCRETE STEM WALL 7D CONCRETE GRADE BEAM 7E CONCRETE CAISSON 8 2x WOOD FRAMING 9 WOOD I-JOISTS. SEE STRUCTURAL DWGS 10 WOOD CONVENTIONAL FRAMED ROOF. SEE STRUCTURAL DRAWINGS. 11 2x CEILING JOIST 12 PLYWOOD ROOF SHEATHING. SEE STRUCT. DWGS. RADIANT BARRIER TO BE INSTALLED PER TITLE 24, REFER TO SHEET T-24.MM FOR INSTALLATION METHODS 13 2 x T&G FLOOR SHEATHING 14 STEEL BEAMS WRAPPED IN WOOD 15 EXPOSED RAFTER TAIL 16 INSULATION, SEE TITLE 24 17 RIGID INSULATION 18 COPPER GUTTER / DOWNSPOUT 19 WOOD GUARDRAIL DETAILING WITH HORIZONTAL STAINLESS STEEL CABLE RAILING - PER DETAIL 12 / D4.2 20 WOOD SIDING 21 WOOD DETAILING 22 WOOD CEILING / SOFFIT / FALSE CEILING BEAMS REFER TO REFLECTED CEILING PLANS 23 DRYWALL CEILING / SOFFIT REFER TO REFLECTED CEILING PLANS TYPICAL 24 WOOD DOORS & WINDOWS 25 SOLID SURFACE STONE TOP 26 STONE TILE WALL CAP 27 BRICK VENEER 28 BUILT - IN CABINETRY REFER TO SHEETS T24-1a & T24-1b FOR CF1R FORMS AND COMPLIANCE INFORMATION I N S U L A T I O N S C H E D U L E Construction Name Surface Type Construction Type Framing Total Cavity Winter Design R-Value U-Value Garage Roof Volume Ceilings Wood Framed Ceiling 2x4 @ 16" o/c None 0.332 Garage Exterior Wall Exterior Walls Wood Framed Wall 2x6 @ 16" o/c None 0.347 R-30 Roof Volume Ceilings Wood Framed Ceiling 2x10 @ 16" o/c R-30 0.036 R-22 Roof Volume Ceilings Wood Framed Ceiling 2x4 @ 16" o/c R-22 0.056 R-21 Wall Exterior Walls Wood Framed Wall 2x6 @ 16" o/c R-21 0.069 R-21 Wall 1 Interior Walls Wood Framed Wall 2x6 @ 16" o/c R-21 0.064 Attic / Roof / Zone 2 Attic Roofs Wood Framed Ceiling 2x4 Truss @ 24" o/c R-30 0.040 R-30 Roof HPA Ceilings Below Attic Wood Framed Ceiling 2x6 @ 24" o/c None 0.478 R-30 Floor Exterior Floors Wood Framed Floor 2x10 @ 24" o/c R-30 0.033No Crawlspace R-19 Floor No Crawlspace Interior Floors Wood Framed Floor 2x6 @ 16" o/c R-19 0.049 NOTE:BUILDING SETBACK DIMENSION IS TO FACE OF FINISH MATERIAL NOTE:BUILDING SETBACK DIMENSION IS TO FACE OF FINISH MATERIAL 8' - 1 " T.O.Shtg. EL. 27.24 T.O. Sheathing EL.36.40 8' - 1 1 " T.Pl. EL. 35.32 T.O.Slab EL. 17.25 T.Pl. EL. 26.16 Max Height EL.46.25 B.O.Slab EL. 16.00 7' - 0 3 4" B.O.Hdr. EL. 43.46 7'- 7 1 2" T.Pl. EL. 44.02 3'-0"3'-0" Setback Setback 29 ' - 0 " T.O. Sheathing EL.36.40 8' - 1 " 8' - 1 1 " T.O.Slab EL. 17.25 T.Pl. EL. 26.16 T.O.Shtg. EL. 27.24 T.Pl. EL. 35.32 Maximum Height EL.46.25 B.O.Slab EL. 16.00 B.O.Hdr. EL. 43.46 7' - 0 3 4" T.Pl. EL. 44.02 7' - 7 1 2" H.P.of Garage EL. 11.85 T.Pl. EL. 18.93 T.O.Shtg. EL. 20.01 7'- 1 " 1'- 1 " 8' - 0 " 10 3 4" 7' - 0 " 1' - 7 3 4" 3'- 8 " T.Pl. EL. 28.01 T.O.Shtg. EL. 28.90 T.O.Shtg. EL. 37.54 T.O.Railing EL. 41.25 T.Pl. EL. 35.90 6' - 4 1 2" 7' - 0 3 4" B.O.Hdr. EL. 27.07 7' - 0 3 4" 8' - 0 3 4" B.O.Hdr. EL. 35.28 P L 29 ' - 0 " 2'-0"3'-0" 5'-0" P L 2nd Front Setback 15'-0" Building Setback 24' Above T.O. Slab 2' - 0 " Right Side Elevation SCALE: 1/4" = 1'-0" BUILDING ELEVATIONS PLOT REFERENCE DATE: 03-22-23 SHEET NUMBER: 503 32ND STREET, SUITE 130 TELEPHONE: (949) 584-8987 NEWPORT BEACH, CA 92663 Email: ritnergroup.com STAMP: TELEPHONE: FAX: A5.1 SHEET TITLE: ‹RITNER GROUP, INC. 2023 expressly reserves all common law copyright and property rights in these plans. These plans are not to be reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party without first obtaining the express written permission and consent of RITNER GROUP, INC. PROJECT DESIGNER: PROJECT CAD FILE: PROJECT NUMBER: DRAWN BY: PROJECT MANAGER: 22012-ELEV O: \ 2 0 2 2 - P R O J E C T S \ 2 2 0 1 2 \ C D \ 2 2 0 1 2 - E L E V Ma r c h 2 9 , 2 0 2 3 BG RR 22012 Lot 4, Block 39 Pr o g r e s s S e t / 0 3 - 2 2 - 2 3 PROJECT: BUILDING DEPARTMENT SUBMITTAL: - REVISIONS: --- Front Elevation SCALE: 1/4" = 1'-0" ELEVATION NOTES ROOFING MATERIAL: ELEVATION KEY NOTES GUTTERS / DOWNSPOUTS: 5" DIAMETER HALF ROUND COPPER GUTTERS AND DOWNSPOUTS - ALL COPPER TO BE DARK BROWN IN COLOR BRICK VENEER: BUILDING PAPER:PROVIDE A MINIMUM OF TWO LAYERS OF GRADE "D" PAPER OVER ALL WOOD BASED SHEATHING AND UNDER ALL GROUT BASED MASONRY VENEERS. VAPOR BARRIER:PROVIDE VAPOR BARRIER AROUND ALL WALL PENETRATIONS INCLUDING DOORS AND WINDOWS PER DETAILS CHIMNEY TERMINATION: CHIMNEY SHALL EXTEND AT LEAST 2' HIGHER THAN ANY PORTION OF THE BUILDING WITH IN 10'-0", BUT SHALL NOT BE LESS THAN 3' ABOVE THE HIGHEST POINT WHERE THE CHIMNEY PASSES THROUGH THE ROOF. BRICK VENEER ( 1.5" THICK) MERIDIAN / OLD BAILEY BY MERIDIAN / BORAL BRICK, ICC REPORT ESR-1364 (OR EQUAL) DOES NOT EXCEED 15 POUDS LPER SQ. FT. ADHERED MASONRY VENEER SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF SECTION 1405.10.1 AND SECTION 6.1 AND 6.3 OF TMS 401/ACI 530/ASCE 5. WOOD SIDING:HARDBOARD SIDING BY "JAMES HARDIE" PAINTED. REFER TO COLOR SCHEME WOOD TRIM:2x WOOD TRIM PAINTED. REFER TO COLOR SCHEME 1 STANDING SEAM METAL ROOF 5 7 10 3 1 x 9 VERTICAL WOOD SIDING WITH WOOD DOORS & WINDOWS COLOR - PAINTED REFER TO COLOR SCHEME EXPOSED WOOD BEAM / CORBEL COLOR - PAINTED 11 GARAGE DOORS : COLOR - PAINTED MERIDIAN / BORAL MANUFACTURED BRICK 3/8" STRAIGHT GROVE 6 REFER TO COLOR SCHEME COLOR - PAINTED 4 8 CHIMNEY CAP - COPPER COLOR - NATURAL AGED 9 WOOD ENTRY DOOR COLOR - PAINTED 2 EXPOSED WOOD RAFTER TAILS COLOR - PAINTED 12 13 WOOD GATE : WOOD GUARDRAIL DETAILING WITH HORIZONTALS STAINLESS STEEL CABLE RAILING - COLOR - PAINTED COLOR - PAINTED REFER TO COLOR SCHEME 20 1 x 9 HORIZONTAL WOOD SIDING WITH 3/8" STRAIGHT GROVE COLOR - PAINTED EXTERIOR LIGHT FIXTURE 16 17 GUTTERS / DOWNSPOUT 15 WOOD DETAILING COLOR - STAIN COPPER EYEBROW ENVIRONMENTAL AIR DUCT VENT REFER TO MANUFACTURER SPECIFICATION21 DIRECT VENT TERMINATION CAP REFER TO MANUFACTURER SPECIFICATIONS STONE COUNTER TOP ANTIQUE FINISH19 WOOD SOFFIT DETAILING COLOR - STAIN18 HOUSE STREET NUMBER VISIBLE AND LEGIBLE FROM STREET (MINIMUM 4" HIGH x 1" WIDE) CRC R31922 STANDING SEAM PANEL ROOF BY:"CUSTOM-BILT METALS" CB-2000 2" PREFINISHED ALUMINUM RATED UL-580 CLASS 90 TESTED ASTM E-1592, E-1680 & E-1646 REFER TO COLOR SCHEME EXPOSED WOOD BOXED COLUMN COLOR - PAINTED REFER TO COLOR SCHEME REFER TO COLOR SCHEME REFER TO COLOR SCHEME REFER TO COLOR SCHEME REFER TO COLOR SCHEME REFER TO COLOR SCHEME REFER TO COLOR SCHEME 14 GLASS GUARDRAIL DETAILING LOUVERED BREAKAWAY WALL SHALL COMPLY WITH:23 ASCE 24 Sections 4.6.1 & 4.6.2 ASCE 7 Section 5.3.3 T.Pl. EL. 18.93 HP of Garage EL. 11.85 T.O.Shtg. EL. 20.01 7'- 1 " T.Pl. EL. 28.01 7' - 0 " 10 3 4" 1' - 7 3 4" T.O.Railing EL. 41.25 T.O.Shtg. EL. 37.54 1' - 1 " 3' - 8 " 8' - 0 " T.O.Shtg. EL. 28.90 6' - 4 1 2" 7' - 0 3 4" B.O.Hdr. EL. 27.07 B.O.Hdr. EL. 35.28 T.Pl. EL. 35.90 3 12 T.O.Slab EL. 17.25 Maximum Height EL.46.25 29 ' - 0 " 3'-0"3'-0" SetbackSetback 8' - 1 " 8' - 1 1 " T.O.Shtg. EL. 27.24 B.O.Slab EL. 16.00 T.O. Sheathing EL.36.40 T.Pl. EL. 26.16 T.O.Slab EL. 17.25 Maximum Height EL.46.25 T.Pl. EL. 35.32 7' - 0 3 4" B.O.Hdr. EL. 43.46 T.Pl. EL. 44.02 7' - 7 1 2" H.P. of Garage EL. 11.85 T.O.Shtg. EL. 20.01 T.Pl. EL. 18.93 7'- 1 " 1'- 1 " 8'- 0 " 10 3 4" T.Pl. EL. 28.01 T.O.Shtg. EL. 37.54 7' - 0 " 3'- 8 " T.O.Shtg. EL. 28.90 1' - 7 3 4" T.O.Railing EL. 41.25 T.Pl. EL. 35.90 6' - 4 1 2" B.O.Hdr. EL. 27.07 7' - 0 3 4" B.O.Hdr. EL. 35.28 B.O.Hdr. EL. 35.28 2'-0"3'-0" 5'-0"15'-0" P L Building Setback 2nd Front Setback 24' Above T.O. Slab 2' - 0 " Left Side Elevation BUILDING ELEVATIONS PLOT REFERENCE DATE: 03-22-23 SHEET NUMBER: 503 32ND STREET, SUITE 130 TELEPHONE: (949) 584-8987 NEWPORT BEACH, CA 92663 Email: ritnergroup.com STAMP: TELEPHONE: FAX: A5.2 SHEET TITLE: ‹RITNER GROUP, INC. 2023 expressly reserves all common law copyright and property rights in these plans. These plans are not to be reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party without first obtaining the express written permission and consent of RITNER GROUP, INC. PROJECT DESIGNER: PROJECT CAD FILE: PROJECT NUMBER: DRAWN BY: PROJECT MANAGER: 22012-ELEV O: \ 2 0 2 2 - P R O J E C T S \ 2 2 0 1 2 \ C D \ 2 2 0 1 2 - E L E V Ma r c h 2 9 , 2 0 2 3 BG RR 22012 Lot 4, Block 39 Pr o g r e s s S e t / 0 3 - 2 2 - 2 3 PROJECT: BUILDING DEPARTMENT SUBMITTAL: - REVISIONS: --- Rear Elevation SCALE: 1/4" = 1'-0" ELEVATION NOTES ROOFING MATERIAL: ELEVATION KEY NOTES GUTTERS / DOWNSPOUTS: 5" DIAMETER HALF ROUND COPPER GUTTERS AND DOWNSPOUTS - ALL COPPER TO BE DARK BROWN IN COLOR BRICK VENEER: BUILDING PAPER:PROVIDE A MINIMUM OF TWO LAYERS OF GRADE "D" PAPER OVER ALL WOOD BASED SHEATHING AND UNDER ALL GROUT BASED MASONRY VENEERS. VAPOR BARRIER:PROVIDE VAPOR BARRIER AROUND ALL WALL PENETRATIONS INCLUDING DOORS AND WINDOWS PER DETAILS CHIMNEY TERMINATION: CHIMNEY SHALL EXTEND AT LEAST 2' HIGHER THAN ANY PORTION OF THE BUILDING WITH IN 10'-0", BUT SHALL NOT BE LESS THAN 3' ABOVE THE HIGHEST POINT WHERE THE CHIMNEY PASSES THROUGH THE ROOF. BRICK VENEER ( 1.5" THICK) MERIDIAN / OLD BAILEY BY MERIDIAN / BORAL BRICK, ICC REPORT ESR-1364 (OR EQUAL) DOES NOT EXCEED 15 POUDS LPER SQ. FT. ADHERED MASONRY VENEER SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF SECTION 1405.10.1 AND SECTION 6.1 AND 6.3 OF TMS 401/ACI 530/ASCE 5. WOOD SIDING:HARDBOARD SIDING BY "JAMES HARDIE" PAINTED. REFER TO COLOR SCHEME WOOD TRIM:2x WOOD TRIM PAINTED. REFER TO COLOR SCHEME 1 STANDING SEAM METAL ROOF 5 7 10 3 1 x 9 VERTICAL WOOD SIDING WITH WOOD DOORS & WINDOWS COLOR - PAINTED REFER TO COLOR SCHEME EXPOSED WOOD BEAM / CORBEL COLOR - PAINTED 11 GARAGE DOORS : COLOR - PAINTED MERIDIAN / BORAL MANUFACTURED BRICK 3/8" STRAIGHT GROVE 6 REFER TO COLOR SCHEME COLOR - PAINTED 4 8 CHIMNEY CAP - COPPER COLOR - NATURAL AGED 9 WOOD ENTRY DOOR COLOR - PAINTED 2 EXPOSED WOOD RAFTER TAILS COLOR - PAINTED 12 13 WOOD GATE : WOOD GUARDRAIL DETAILING WITH HORIZONTALS STAINLESS STEEL CABLE RAILING - COLOR - PAINTED COLOR - PAINTED REFER TO COLOR SCHEME 20 1 x 9 HORIZONTAL WOOD SIDING WITH 3/8" STRAIGHT GROVE COLOR - PAINTED EXTERIOR LIGHT FIXTURE 16 17 GUTTERS / DOWNSPOUT 15 WOOD DETAILING COLOR - STAIN COPPER EYEBROW ENVIRONMENTAL AIR DUCT VENT REFER TO MANUFACTURER SPECIFICATION21 DIRECT VENT TERMINATION CAP REFER TO MANUFACTURER SPECIFICATIONS STONE COUNTER TOP ANTIQUE FINISH19 WOOD SOFFIT DETAILING COLOR - STAIN18 HOUSE STREET NUMBER VISIBLE AND LEGIBLE FROM STREET (MINIMUM 4" HIGH x 1" WIDE) CRC R31922 STANDING SEAM PANEL ROOF BY:"CUSTOM-BILT METALS" CB-2000 2" PREFINISHED ALUMINUM RATED UL-580 CLASS 90 TESTED ASTM E-1592, E-1680 & E-1646 REFER TO COLOR SCHEME EXPOSED WOOD BOXED COLUMN COLOR - PAINTED REFER TO COLOR SCHEME REFER TO COLOR SCHEME REFER TO COLOR SCHEME REFER TO COLOR SCHEME REFER TO COLOR SCHEME REFER TO COLOR SCHEME REFER TO COLOR SCHEME 14 GLASS GUARDRAIL DETAILING LOUVERED BREAKAWAY WALL SHALL COMPLY WITH:23 ASCE 24 Sections 4.6.1 & 4.6.2 ASCE 7 Section 5.3.3 SCALE: 1/4" = 1'-0" N52 46'30"E 79.46' N3 9 5 3 ' 3 0 " W 2 5 . 0 3 ' N3 9 3 5 ' 3 0 " W 2 5 . 0 2 ' N52 46'30"E 79.33' Total Second Level Living "B" = 583 sq.ft Total Second Level Living "B" = 590 sq.ft 30'-11" 18 ' - 1 0 " 3' - 4 " 6" 4" 3' - 0 " 1'-2" 3' - 6 " 4" 3'- 8 " 25'-6" 18 ' - 1 0 " 5'-0" 11 ' - 1 0 " 4'-6" 5' - 1 1 2" 3'-2" 3' - 6 " 10 ' - 5 " 10" 6" x 3'-4" B2 = 2 sq.ft B 30'-11" x 18'-10" B1 = 582 sq.ft 4" x 3' B3 = 1 sq.ft 1'-2" x 3'-6" B4 = 4 sq.ft 4" x 3'-8" B5 = 1 sq.ft Second Level Master Deck "C" = 71 sq.ft Second Level Kitchen Deck "C" = 35 sq.ft 4'-6" x 5'-1 1/2" B6 = 23 sq.ft 6" x 3'-4" C2 = 2 sq.ft 3'-2" x 3'-6" B10 = 11 sq.ft 25'-6" x 18'-10" B7 = 480 sq.ft 5' x 11'-10" B8 = 60 sq.ft 3'-9" x 18'-10" C1 = 71 sq.ft 3'-9" 18 ' - 1 0 10" x 10'-5" B9 = 9 sq.ft B A N52 46'30"E 79.46' N3 9 5 3 ' 3 0 " W 2 5 . 0 3 ' N3 9 3 5 ' 3 0 " W 2 5 . 0 2 ' LOT 3 N52 46'30"E 79.33' Total Main Level Living "A" = 568 sq.ft Total Garage Area "F" = 414 sq.ft 18 ' - 1 0 " 20'-0" 3' - 0 " 6'-9" 2'-4" 7' - 1 1 2" 6'-9" x 3' G2 = 20 sq.ft 20' x 18'-10" G1 = 377 sq.ft 2'-4" x 7'-1 1/2" G3 = 17 sq.ft 18 ' - 1 0 " 20'-41 2" 5'-6" 3' - 3 1 2" 7'-10" 9' - 2 1 2" 6'-9" 5'- 5 " 6' - 4 " 4'-1"4'-5" 7' - 1 1 2" 20'-4 1/2" x 18'-10" A1 = 384 sq.ft 5'-6" x 3'-3 1/2" A2 = 18 sq.ft 7'-10" x 9'-2 1/2" A3 = 72 sq.ft 6'-9" x 5'-5" A4 = 37 sq.ft 4'-1" x 6'-4" A5 = 26 sq.ft 4'-5" x 7'-1 1/2" A6 = 31 sq.ft A OVERLAY PLANS PLOT REFERENCE DATE: 03-29-23 SHEET NUMBER: 503 32ND STREET, SUITE 130 TELEPHONE: (949) 584-8987 NEWPORT BEACH, CA 92663 Email: ritnergroup.com STAMP: TELEPHONE: FAX: A9.1 SHEET TITLE: ‹RITNER GROUP, INC. 2023 expressly reserves all common law copyright and property rights in these plans. These plans are not to be reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party without first obtaining the express written permission and consent of RITNER GROUP, INC. PROJECT DESIGNER: PROJECT CAD FILE: PROJECT NUMBER: DRAWN BY: PROJECT MANAGER: 22012-FLOOR-OVERLAY O: \ 2 0 2 2 - P R O J E C T S \ 2 2 0 1 2 \ C D \ 2 2 0 1 2 - F L O O R - O V E R L A Y Ma r c h 2 9 , 2 0 2 3 BG RR 22012 Lot 4, Block 39 Pr o g r e s s S e t / 0 3 - 2 9 - 2 3 PROJECT: BUILDING DEPARTMENT SUBMITTAL: - REVISIONS: --- First Level - Overlay Plan SCALE: 1/4" = 1'-0" Second Level - Overlay Plan SCALE: 1/4" = 1'-0" Allowable Floor Area: Allowable combined Exception : Sec 20.48.180.A.1.b.i Planning Criteria SETBACKS: 0'Front 5'2nd Front 3'Side Yard 1 MAXIMUM HEIGHT: 24'Flat Roof (less than 3:12 pitch) 29'Pitched Roof (greater than 3:12 pitch) FAR: 2,024 Sq. Ft.Site Area MAXIMUM FLOOR AREA LIMIT: Buildable Area 2,826 Sq. Ft.Buildable Area 1,413 x 2 = 3'Side Yard 2 1,413 Sq. Ft. Development Standards R-2 Zone PARKING REQUIREMENTS: 2 Car off Street Parking Minimum Minimum Interior dimensions for Parking spaces in residential zoning for a lot width 30'-0" feet or less is 17'-6"x19'-0" (20.40) City of Newport Beach Area Tabulation Living Area: 2 Car Garage First Level Living 590 Sq.Ft.Second Level Living 568 Sq.Ft. 257 Sq.Ft.Third Level Living 1,415 Sq.Ft.Total Living Total Building Area 583 Sq.Ft. - 294 Sq.Ft. 877 Sq.Ft. Unit A Unit B 414 Sq.Ft. 1,173 Sq.Ft. 568 Sq.Ft. 551 Sq.Ft. 2,292 Sq.Ft. 2,706 Sq.Ft. Total 71 Sq.Ft.Level 2 Roof Deck 35 Sq.Ft.106 Sq.Ft. Carport 282 Sq.Ft. THIRD FLOOR LIMITATIONS: Only subsection (A)(2)(c) applyFloor & Deck Area: 15' from Front & Rear Setback LinesLocation of Structure: 388 Sq.Ft.Level 3 Roof Deck 304 Sq.Ft.692 Sq.Ft. 459 Sq.Ft.Total Roof Deck 339 Sq.Ft.798 Sq.Ft. Hatching Indicates Garage Area and Deck Area Hatching Indicates Living Area Hatching Legend Area OverlayTabulation 384 Sq. Ft.A1: 18 Sq. Ft.A2: Total First Level / Unit A 72 Sq. Ft.A3: 37 Sq. Ft.A4: 26 Sq. Ft.A5: 31 Sq. Ft.A6: 568 Sq. Ft.Area: 582 Sq. Ft.B1: 2 Sq. Ft.B2: Total Second Level / Unit A 1 Sq. Ft.B3: 4 Sq. Ft.B4: 1 Sq. Ft.B5: 590 Sq. Ft.Area: 23 Sq. Ft.B6: 480 Sq. Ft.B7: Total Second Level / Unit B 60 Sq. Ft.B8: 9 Sq. Ft.B9: 11 Sq. Ft.B10: 583 Sq. Ft.Area: Second Level Master Deck / Unit A 71 Sq. Ft.C1: 71 Sq. Ft.Area: Second Level Kitchen Deck / Unit B 35 Sq. Ft.C2: 35 Sq. Ft.Area: 240 Sq. Ft.D1: 17 Sq. Ft.D2: Total Third Level / Unit A 257 Sq. Ft.Area: 16 Sq. Ft.D3: Total Third Level / Unit B 22 Sq. Ft.D4: 245 Sq. Ft.D5: 11 Sq. Ft.D6: 294 Sq. Ft.Area: 116 Sq. Ft.E1: Total Third Level Deck / Unit A 106 Sq. Ft.E2: 78 Sq. Ft.E3: 88 Sq. Ft.E4: 388 Sq. Ft.Area: 21 Sq. Ft.E5: Total Third Level Deck / Unit B 257 Sq. Ft.E6: 26 Sq. Ft.E7: 304 Sq. Ft.Area: N52 46'30"E 79.46' N3 9 5 3 ' 3 0 " W 2 5 . 0 3 ' N3 9 3 5 ' 3 0 " W 2 5 . 0 2 ' LOT 5 N52 46'30"E 79.33' Total Third level Living "D" = 294 sq.ftB Total Third level Living "D" = 257 sq.ft A 16'-8" 14 ' - 4 " 1' - 0 " 16'-0" 4" 6' - 3 " 3' - 9 " 4'-2"16'-21 2" 3' - 6 " 6'-1" 3' - 4 " 3'-2" 16'-8" x 14'-4" D1 = 240 sq.ft 16' x 1' D2 = 17 sq.ft 15 ' - 1 1 2" Roof Terrace Area "E" = 388 sq.ft 6'-1" x 3'-6" D4 = 22 sq.ft 4'-2" x 3'-9" D3 = 16 sq.ft 16'-2 1/2" x 15'-1 1/2" D5 = 245 sq.ft 3'-2" x 3'-4" D6 = 11 sq.ft 4" x 6'-3" D3 = 2 sq.ft 6'-2"6'-2"22'-4" 18 ' - 1 0 " 17 ' - 2 1 2" 15 ' - 4 " 3' - 6 " 22'-4" x 3'-6" E3 = 78 sq.ft 6'-2" x 17'-2 1/2" E2 = 106 sq.ft 6'-2" x 18'-10" E1 = 116 sq.ft 5'-8" x 15'-4" E4 = 88 sq.ft 5'-8" Roof Terrace Area "E" = 304 sq.ft 1' - 1 0 " 11'-6" 13 ' - 0 " 19'-91 2"2'-3" 11 ' - 6 " 11'-6" x 1'-10" E5 = 21 sq.ft 2'-3" x 11'-6" E7 = 26 sq.ft 19'-9 1/2" x 13' E6 = 257 sq.ft Third Level - Overlay Plan SCALE: 1/4" = 1'-0" OVERLAY PLANS PLOT REFERENCE DATE: 03-29-23 SHEET NUMBER: 503 32ND STREET, SUITE 130 TELEPHONE: (949) 584-8987 NEWPORT BEACH, CA 92663 Email: ritnergroup.com STAMP: TELEPHONE: FAX: A9.2 SHEET TITLE: ‹RITNER GROUP, INC. 2023 expressly reserves all common law copyright and property rights in these plans. These plans are not to be reproduced, changed or copied in any form or manner whatsoever, nor are they to be assigned to any third party without first obtaining the express written permission and consent of RITNER GROUP, INC. PROJECT DESIGNER: PROJECT CAD FILE: PROJECT NUMBER: DRAWN BY: PROJECT MANAGER: 22012-FLOOR-OVERLAY O: \ 2 0 2 2 - P R O J E C T S \ 2 2 0 1 2 \ C D \ 2 2 0 1 2 - F L O O R - O V E R L A Y Ma r c h 2 9 , 2 0 2 3 BG RR 22012 Lot 4, Block 39 Pr o g r e s s S e t / 0 3 - 2 9 - 2 3 PROJECT: BUILDING DEPARTMENT SUBMITTAL: - REVISIONS: --- Hatching Indicates Garage Area and Deck Area Hatching Indicates Living Area Hatching Legend Allowable Floor Area: Allowable combined Exception : Sec 20.48.180.A.1.b.i Planning Criteria SETBACKS: 0'Front 5'2nd Front 3'Side Yard 1 MAXIMUM HEIGHT: 24'Flat Roof (less than 3:12 pitch) 29'Pitched Roof (greater than 3:12 pitch) FAR: 2,024 Sq. Ft.Site Area MAXIMUM FLOOR AREA LIMIT: Buildable Area 2,826 Sq. Ft.Buildable Area 1,413 x 2 = 3'Side Yard 2 1,413 Sq. Ft. Development Standards R-2 Zone PARKING REQUIREMENTS: 2 Car off Street Parking Minimum Minimum Interior dimensions for Parking spaces in residential zoning for a lot width 30'-0" feet or less is 17'-6"x19'-0" (20.40) City of Newport Beach Area Tabulation Living Area: 2 Car Garage First Level Living 590 Sq.Ft.Second Level Living 568 Sq.Ft. 257 Sq.Ft.Third Level Living 1,415 Sq.Ft.Total Living Total Building Area 583 Sq.Ft. - 294 Sq.Ft. 877 Sq.Ft. Unit A Unit B 414 Sq.Ft. 1,173 Sq.Ft. 568 Sq.Ft. 551 Sq.Ft. 2,292 Sq.Ft. 2,706 Sq.Ft. Total 71 Sq.Ft.Level 2 Roof Deck 35 Sq.Ft.106 Sq.Ft. Carport 282 Sq.Ft. THIRD FLOOR LIMITATIONS: Only subsection (A)(2)(c) applyFloor & Deck Area: 15' from Front & Rear Setback LinesLocation of Structure: 388 Sq.Ft.Level 3 Roof Deck 304 Sq.Ft.692 Sq.Ft. 459 Sq.Ft.Total Roof Deck 339 Sq.Ft.798 Sq.Ft. Area OverlayTabulation 384 Sq. Ft.A1: 18 Sq. Ft.A2: Total First Level / Unit A 72 Sq. Ft.A3: 37 Sq. Ft.A4: 26 Sq. Ft.A5: 31 Sq. Ft.A6: 568 Sq. Ft.Area: 582 Sq. Ft.B1: 2 Sq. Ft.B2: Total Second Level / Unit A 1 Sq. Ft.B3: 4 Sq. Ft.B4: 1 Sq. Ft.B5: 590 Sq. Ft.Area: 23 Sq. Ft.B6: 480 Sq. Ft.B7: Total Second Level / Unit B 60 Sq. Ft.B8: 9 Sq. Ft.B9: 11 Sq. Ft.B10: 583 Sq. Ft.Area: Second Level Master Deck / Unit A 71 Sq. Ft.C1: 71 Sq. Ft.Area: Second Level Kitchen Deck / Unit B 35 Sq. Ft.C2: 35 Sq. Ft.Area: 240 Sq. Ft.D1: 17 Sq. Ft.D2: Total Third Level / Unit A 257 Sq. Ft.Area: Third Level Roof Deck - Overlay Plan SCALE: 1/4" = 1'-0" 16 Sq. Ft.D3: Total Third Level / Unit B 22 Sq. Ft.D4: 245 Sq. Ft.D5: 11 Sq. Ft.D6: 294 Sq. Ft.Area: 116 Sq. Ft.E1: Total Third Level Deck / Unit A 106 Sq. Ft.E2: 78 Sq. Ft.E3: 88 Sq. Ft.E4: 388 Sq. Ft.Area: 21 Sq. Ft.E5: Total Third Level Deck / Unit B 257 Sq. Ft.E6: 26 Sq. Ft.E7: 304 Sq. Ft.Area: