Loading...
HomeMy WebLinkAboutPA2022-0318_20230316_Plans 36x245'-1" 5'-1" 20 ' - 0 " 11 ' - 8 " 70.06' P.L. 12 8 . 2 9 ' P . L . 70.00' P.L. 12 5 . 5 3 ' P . L . SAINT ANDREWS 30 ' - 0 " 28'-10" 4' - 0 " 6' - 0 " 35 ' - 0 " 2' - 7 " 3'-10" 10'-3" 5' - 6 " 19'-0" S.F.D. 1,916 Sq.Ft. 2-STORY EXISTING GARAGE 418 Sq.Ft. 2-CAR EXISTING FRONT YARD BACK YARD EXISTING GAS METER EXISTING COV. PORCH 20 Sq.Ft. EXISTING ELECTRICAL METER 5'-1" 41 ' - 5 " 2% 2% 5% 5% 5%5% 5% 5% 2% 2% 2% 2% 2% 2% ADDITION 528 Sq.Ft. 1-STORY 11 ' - 0 " 19 ' - 0 " CURB FACE 24'-0" NEW OPEN FRAME TRELLIS 144 Sq.Ft.EXISTING 2% 2% 2% 2 % 2% 2% 2% 2% 22 ' - 0 " 8' - 0 " 18'-0" 8' - 0 " 22 ' - 0 " 12 ' - 0 " 19'-0"4' - 5 " 2ND FLOOR ADDITION 84 Sq.Ft. 308 Sq.Ft. 88 Sq.Ft.MI N . 2 0 ' - 0 " R E Q . MIN. 4'-0" REQ. MI N . 1 0 ' - 0 " R E Q . MIN. 4'-0" REQ. EXISTING 6' HIGH WOOD FENCE EXISTING 6' HIGH WOOD FENCE W/ GATE SET-BACK SE T - B A C K SE T - B A C K SET-BACK 4'-0" 4'-0" MIN. REQ. MIN. REQ. 103.2 NG 103.6 NG 103.45 NG 103.47 NG 103.3 NG 100 . 1 1 T C 99.7 0 F L 100 . 2 9 T C 99.9 2 F L 100 . 0 3 T C 99.6 3 F L 102.25 NG 102.6 NG a a a a a a a aaa a a 120.41 PEAK a 124.15 RIDGE a 103 . 1 2 TRASH AREA a EXISTING COV. PATIO 195 Sq.Ft. POOL / SPA 62'-0" 98 ' - 1 " 62'-1" 95 ' - 4 " 39'-0" OPEN AREA 39' x 41' = 1,599 Sq.Ft. 101.40 NGLOWEST P O I N T a 1ST FLOOR EXISTING ADDITION ON 2ND FLOORINTERIOR REMODEL LINE PROPERTY ADDITION ON 1ST FLOOR EXISTING 2ND FLOOR REVISIONS BY 1 SCOPE OF WORK PROJECT DIRECTORY PROPERTY OWNER: PLOT PLAN BUILDING DATA PLOT PLAN SCALE 1/8" = 1'-0" 2066 LUIS L. AS NOTED 02.24.2023 30 6 S A I N T A N D R E W S R D NE W P O R T B E A C H , C A 9 2 6 6 3 AP N : 0 4 9 - 2 3 0 - 1 1 TR A C T : 1 2 2 0 LO T : 4 4 DATE SCALE DRAWN JOB SHEET REVISIONS BY SHEET TITLE of sheets JO B A D D R E S S LE G A L D E S C R I P T I O N a 02.24.2023 L.L. b -- DRAWINGS PREPARED BY LUIS LOPEZ 03.02.2023 (714) 417-7771 OCBuildersGroup.com PL A N C H E C K N O . c -- 23 LEGEND BUILDING AREA CALCULATION A.LOT AREA: -LOT SIZE:5,125 Sq.Ft. EXISTING PROPOSED CHANGE B.FIRST FLOOR 1,492 Sq.Ft. 528 Sq.Ft. 2,020 Sq.Ft. C.SECOND FLOOR 418 Sq.Ft. 84 Sq.Ft. 502 Sq.Ft. D.TOTAL FLOOR AREA 1,910 Sq.Ft. 612 Sq.Ft. 2,522 Sq.Ft. E.GARAGE 418 Sq.Ft. 0 Sq.Ft. 418 Sq.Ft. F.COVERED PORCH 20 Sq.Ft. 0 Sq.Ft. 20 Sq.Ft. G.COVERED PATIO 195 Sq.Ft. 0 Sq.Ft. 195 Sq.Ft. H.TRELLIS FRAME 0 Sq.Ft. 144 Sq.Ft. 144 Sq.Ft. OPEN VOLUME CALCULATION I.BUILDABLE AREA (LOT AREA, NOT INCLUDING SETBACKS) : 6,003.3 Sq.Ft. J.OPEN AREA REQUIRED : I x 0.15 : 6,003.3 x 0.15 = 900.5 (MIN REQ'D.) K.OPEN AREA PROPOSED: 39' x 41' = 1,599 Sq.Ft. AREA SUMMARY T-24 ENERGY: (626) 289 - 8808 Perfect Design Alhambra, CA 91803 2416 W. Valley Blvd. ENGINEER: (562) 805 - 7737 17715 Canehill Ave Bellflower, CA 90706 John Tiongco LIC. NO. C70915 722 Sq.Ft. INTERIOR REMODEL, INCLUDING CONVERTING A BEDROOM TO DINING ROOM AND RE-LOCATING STAIRWAY. 528 Sq.Ft. ADDITION ON 1ST FLOOR OF FAMILY ROOM AND TO EXTEND KITCHEN 84 Sq.Ft. ADDITION ON 2ND FLOOR NPDES Notes Notes must be shown as worded, on the title sheet of the plan. 1. In the case of emergency, call at Work Phone # or Home Phone # 2. Sediment from areas disturbed by construction shall be retained on site using structural controls to the maximum extent practicable. 3. Stockpiles of soil shall be properly contained to minimize sediment transport from the site to streets, drainage facilities or adjacent properties via runoff, vehicle tacking, or wind. 4. Appropriate BMP’s for construction-related materials, wastes, spills shall be implemented to minimize transport from the site to streets, drainage facilities, or adjoining properties by wind or runoff. 5. Runoff from equipment and vehicle washing shall be contained at construction sites unless treated to reduce or remove sediment and other pollutants. 6. All construction contractor and subcontractor personnel are to be made aware or the required best management practices and good housekeeping measures for the project site and any associated construction staging areas. 7. At the end of each day of construction activity all construction debris and waste materials shall be collected and properly disposed in trash or recycle bins. 8. Construction sites shall be maintained in such a condition that an anticipated storm does not carry wastes or pollutants off the site. Discharges of material other than stormwater only when necessary for performance and completion of construction practices and where they do not: cause or contribute to a violation of any water quality standard; cause or threaten to cause pollution, contamination, or nuisance; or contain a hazardous substance in a quantity reportable under Federal Regulations 40 CFR Parts 117 and 302. 9. Potential pollutants include but are not limited to: solid or liquid chemical spills; wastes from paints, stains, sealants, glues, limes, pesticides, herbicides, wood preservatives and solvents; asbestos fibers, paint flakes or stucco fragments; fuels, oils, lubricants, and hydraulic, radiator or battery fluids; fertilizers, vehicle/equipment wash water and concrete wash water; concrete, detergent or floatable wastes; wastes from any engine/equipment steam cleaning or chemical degreasing and super chlorinated potable water line flushing. During construction, permittee shall dispose of such materials in a specified and controlled temporary area on-site, physically separated from potential stormwater runoff, with ultimate disposal in accordance with local, state and federal requirements. 10. Dewatering of contaminated groundwater, or discharging contaminated soils via surface erosion is prohibited. Dewatering of non- contaminated groundwater requires a National Pollutant Discharge Elimination System Permit from the respective State Regional Water Quality Control Board. 11. Graded areas on the permitted area perimeter must drain away from the face of slopes at the conclusion of each working day. Drainage is to be directed toward desilting facilities. 12. The permittee and contractor shall be responsible and shall take necessary precautions to prevent public trespass onto areas where impounded water creates a hazardous condition. 13. The permittee and contractor shall inspect the erosion control work and insure that the work is in accordance with the approved plans. 14. The permittee shall notify all general contractors, subcontractors, material suppliers, lessees, and property owners: that dumping of chemicals into the storm drain system or the watershed is prohibited. 15. Equipment and workers for emergency work shall be made available at all times during the rainy season. Necessary materials shall be available on site and stockpiled at convenient locations to facilitate rapid construction of temporary devices when rain is imminent. 16. All removable erosion protective devices shall be in place at the end of each working day when the 5-Day Rain Probability Forecast exceeds 40%. 17. Sediments from areas disturbed by construction shall be retained on site using an effective combination of erosion and sediment controls to the maximum extent practicable, and stockpiles of soil shall be properly contained to minimize sediment transport from the site to streets, drainage facilities or adjacent properties via runoff, vehicle tracking, or wind. 18. Appropriate BMPs for construction-related materials, wastes, spills or residues shall be implemented and retained on site to minimize transport from the site to streets, drainage facilities, or adjoining property by wind or runoff. TABLE OF CONTENTS CONTENTS PLOT PLAN1 SHEET EXISTING / DEMO - 1st FLOOR PLAN2 3 4 5 6 7 ROOF PLAN CONSTRUCTION TYPE: V-B OCCUPANCY GROUP: R3 / U NUMBER OF STORIES: 2 USE : SINGLE FAMILY DWELLING / GARAGE FIRE SPRINKLERED: NO ALL WORK SHALL COMPLY WITH THE FOLLOWING: 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA RESIDENTIAL CODE 2022 CALIFORNIA MECHANICAL CODE 2022 CALIFORNIA PLUMBING CODE 2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA ENERGY CODE 2022 CALIFORNIA GREEN BUILDING CODE 2022 CALIFORNIA ENERGY EFFICIENT STANDARDS 2022 CALIFORNIA FIRE CODE AND APPLICABLE MUNICIPAL CODES NEW - 2nd FLOOR PLAN ABBREVIATIONS @ AT ABV ABOVE ALUM ALUMINUM AFF ABOVE FIN FLOOR BLDG BUILDING BLK'G BLOCKING CAB CABINET CL CENTER LINE CEIL CEILING C.J.CEILING JOIST CLR.CLEAR DIMENSION CONC CONCRETE CORR CORRIDOR CONT CONTINUOUS CONTR CONTRACTOR CPT CARPET DIM DIMENSION DISP DISPENSER DN DOWN (E)EXISTING E EAST EA EACH EA. WAY EACH WAY ELEV ELEVATION EXST'G EXISTING F-E FIRE EXTINGUISHER FIXT FIXTURE FLUO FLUORECENT FOS FACE OF STUD FOW FACE OF WALL FUT.FUTURE GL GLASS OR GLAZING GYP BD GYPSUM BOARD (H)HORIZONTAL HDR HEADER HDWRE HARDWARE HDCP HANDICAPPED HR HOUR MFR MANUFACTURER (N)NEW N NORTH NIC NOT IN CONTRACT NTS NOT TO SCALE oc ON CENTER P.A.POST ABOVE PLAS PLASTER R.R.ROOF RAFTER REV REVISION RMV'D REMOVED RPLC'D REPLACED S SOUTH SHLVS SHELVES SIM SIMILAR Sq.Ft.SQUARE FEET TYP TYPICAL UNO UNLESS NOTED OTHERWISE (V)VERTICAL V.I.F.VERIFY IN FIELD W WEST W/WITH CODES ELEVATIONS CONTRACTOR:OC Builders Group Inc., 600 W. Santa Ana Blvd Suite 114A - 499 Santa Ana, CA 92701 (714) 417 - 7771 Lic. No. B-1052090 NEW - 1ST FLOOR PLAN EXISTING / DEMO - 2nd FLOOR PLAN ELEVATIONS 8 WILLIAM ALLISON 306 SAINT ANDREWS RD NEWPORT BEACH, CA 92663 9 10 11 12 13 14 15 16 17 18 19 20 ELECTRICAL SECTIONS FOUNDATIONS 2ND FLOOR FRAMING ROOF FRAMING STRUCTURAL NOTES POOL NOTES CAL GREEN CAL GREEN T-24 T-24 T-24 SIMPSON STRONGWALL SIMPSON STRONGWALL 21 22 T-2423 GENERAL NOTES 1.SETBACKS ARE MEASURED TO FACE OF FINISH. a TOPOGRAPHIC SURVEY1A NOT USED RdM SURVEYING INC. SCALE 1/8"=1' 306 SAINT ANDREWS NEWPORT BEACH N81°21'30"W 125.36' N6 ° 2 3 ' 4 7 " E 7 0 . 0 5 ' N81°21'30"W 128.10' N8 ° 3 8 ' 3 0 " E 7 0 . 0 0 ' N8 ° 3 8 ' 3 0 " E 8 6 5 . 4 8 ' 18 6 . 3 3 ' 70 . 0 0 ' 60 9 . 1 5 ' RESIDENCE RESIDENCE RESIDENCE SA I N T A N D R E W S 20.1 5.1 4.8 11.0 GARAGE BATH 3 BATH 1 BATH 2 39 ' - 7 " 3'-10" 59'-10" 10'-3"9'-4"2'-5"11'-10"15'-11"6'-3" 39 ' - 7 " 17 ' - 0 " 6' - 4 " 10 ' - 9 " 2' - 1 1 " 2' - 7 " CL O S E T CL O S E T CLOSET ST O R . HALL HALL BEDROOM 3 BEDROOM 2 BEDROOM 1 A B C D E F G HI 2 1 2 3 4 5 6 7 8 9 10 11 12 LIVING ROOM 13 KITCHENSTAIRWAY GARAGE PORCH DINING 2' - 7 " 11 ' - 7 " 8' - 4 " 15 ' - 1 " 59'-10" 19'-0"28'-10" 12'-0" BATH 1 BATH 2 CL O S E T CLOSET ST O R . HALL HALL BEDROOM 2 BEDROOM 1 C D E F G HI LIVING ROOM PORCH BATH 1 BATH 2 CL O S E T CLOSET ST O R . HALL HALL BEDROOM 2 BEDROOM 1 A B C D E F G HI 5 2 7 6 4 LIVING ROOM GARAGE PORCH 111 R. R . C. J . RE M O V E D RE M O V E D 18'-2" INTERIOR CLEAR 21 ' - 2 " I N T E R I O R C L E A R 5'-1" TO P.L.5'-1" TO P.L. 20 ' - 0 " T O P . L . 5'-1" TO P.L.5'-1" TO P.L. 71 ' - 5 " T O P . L . a a a a a a a DATE SCALE DRAWN JOB SHEET REVISIONS BY SHEET TITLE 2 1ST FLOOR PLAN 2066 LUIS L. AS NOTED 02.24.2023 30 6 S A I N T A N D R E W S R D NE W P O R T B E A C H , C A 9 2 6 6 3 AP N : 0 4 9 - 2 3 0 - 1 1 TR A C T : 1 2 2 0 LO T : 4 4 DATE SCALE DRAWN JOB SHEET REVISIONS BY SHEET TITLE of sheets JO B A D D R E S S LE G A L D E S C R I P T I O N a 02.24.2023 L.L. b -- DRAWINGS PREPARED BY LUIS LOPEZ 03.02.2023 (714) 417-7771 OCBuildersGroup.com PL A N C H E C K N O . c -- 23 JOB A WINDOW SYMBOL DOOR SYMBOL2 (N) 6 PAGE NUMBER SECTION NUMBER PAGE NUMBER DETAIL NUMBER 1 A A 1 (E) NEW KEY NOTES EXISTINGNEW WALL EXISTING WALL DEMO WALL W/ BATTERY BACKUP SMOKE DETECTOR, HARDWIREDSD W/ BATTERY BACKUP CARBON MONOXIDE, HARDWIREDCOEXISTING / DEMO - 1ST FLOOR PLAN SCALE 1/4" = 1'-0" LEGEND WINDOW SCHEDULE A SYM SIZE B SYMBOL: A TYPE C D NOTE DOOR SCHEDULE 1 SYM SIZE 2 SYMBOL: 1 TYPE 3 4 NOTE REQ'D. FOR ALL WINDOWS U-Factor : 0.30 MAX SHGC : 0.21 MAX STATUS U-Factor : 0.30 MAX SHGC : 0.21 MAX 11 HUNG 3'-0" X 6'-8"SOLID EXTERIOR DOOR 5 6 7 8 9 - STATUS 10 12 13 14 15 16 17 18 - E F G H I J K L M N O P Q R 4'-0" X 4'-0" 2'-6" X 5'-0"HUNG FIXED5'-0" X 5'-0" 2'-6" X 5'-0"HUNG 3'-0" X 4'-0"HUNG 3'-0" X 4'-0"FIXED 2'-6" X 2'-10"FIXED 3'-0" X 4'-0"FIXED 2'-0" X 3'-0"HUNG HC2'-6" X 6'-8" 2'-8" X 6'-8" 2'-8" X 6'-8" 2'-8" X 6'-8" 2'-4" X 6'-8" HC HC HC SOLID 3'-0" X 4'-0"HUNG CASEMN'T CASEMN'T 2'-0" X 5'-0" 2'-0" X 5'-0" 3'-0" X 4'-0"HUNG 4'-0" X 5'-0"FIXED EXST'G EXST'G EXST'G EXST'G EXST'G EXST'G EXST'G EXST'G TEMP TEMP EXST'G EXST'G EXST'G EXST'G EXST'G EXST'G NEW NEW EXST'G REPLC'D REPLC'D EXST'G NEW 16'-0" X 10'-0" NEW NEW NEW NEW NEW GARAGE DOOR SLIDING POCKET DOORSLIDING TEMP. GLASS TEMP. GLASSSLIDING 7'-0" X 6'-8" EXST'G 2'-0" X 3'-0"HUNG TEMP NEW NEW 2'-6" X 6'-8"NEW HC 2'-8" X 6'-8"HC NEW NEW 2'-8" X 6'-8"SOLID SOLID 2'-6" X 6'-8" GARAGE DOOR EXST'G GARAGE DOOR16'-0" X 7'-0"SOLID 2'-6" X 6'-8" HC 18 NEWHC 2'-6" X 6'-8"HC 2'-6" X 6'-8"HC 2'-6" X 6'-8" POCKET DOORSLIDING 2'-8" X 6'-8" 2'-6" X 6'-8" 4'-0" X 5'-0"FIXED NEWTEMP 4'-0" X 5'-0"FIXED NEWTEMP 4'-0" X 5'-0"FIXED NEWTEMP EXISTING / DEMO GENERAL NOTES 1.SETBACKS ARE MEASURED TO FACE OF FINISH. a BATH 1 BATH 2 CL O S E T CLOSET ST O R . HALL HALL BEDROOM 2 BEDROOM 1 A B C D E F G HI 2 LIVING ROOM GARAGE PORCH 2' - 7 " 11 ' - 7 " 8' - 4 " 15 ' - 1 " 59'-10" 19'-0"28'-10" 12'-0" BATH 1 BATH 2 CL O S E T CLOSET ST O R . HALL HALL BEDROOM 2 BEDROOM 1 C D E F G HI LIVING ROOM PORCH COSD COSD SD SD BATH 1 BATH 2 CL O S E T CLOSET ST O R . HALL HALL BEDROOM 2 BEDROOM 1 A B C D E F G HI 5 2 7 6 4 LIVING ROOM BREAKFAST DINING GARAGE PORCH COSD COSD SD SD 4 4 9 3'-10" 35 ' - 0 " 2' - 0 " 1/2 BATH LAUND KITCHEN 14 15 22 ' - 0 " 6' - 5 " 5' - 5 " 22 ' - 3 " 24'-0"21'-9"10'-3"3'-10" 56 ' - 1 " 16 ' - 6 " R UP FAMILY ROOM UP 11 8 13 PANTRY 10 12 111 N O P Q TRELLIS 30 " M I N 24" MIN 2 4 6 6 7 3' - 0 " M I N 1/4" per FOOT MAX SLOPE 7-3/4" MAX STEP DOWN 1/4" per FOOT MAX SLOPE 3' - 0 " M I N 7-3/4" MAX STEP DOWN 8 8 Y 10 X 10 Y 10 X 10 OPEN FRAME 3'-0"18'-0"3'-0" 8' - 0 " 22 ' - 0 " 18'-2" INTERIOR CLEAR 21 ' - 2 " I N T E R I O R C L E A R 5'-1" TO P.L.5'-1" TO P.L. 20 ' - 0 " T O P . L . 49 ' - 5 " T O P . L . 5'-1" TO P.L.5'-1" TO P.L. a a a a a a TRASH AREA a 8 REVISIONS BY 3 PLAN 2066 LUIS L. AS NOTED 02.24.2023 30 6 S A I N T A N D R E W S R D NE W P O R T B E A C H , C A 9 2 6 6 3 AP N : 0 4 9 - 2 3 0 - 1 1 TR A C T : 1 2 2 0 LO T : 4 4 DATE SCALE DRAWN JOB SHEET REVISIONS BY SHEET TITLE of sheets JO B A D D R E S S LE G A L D E S C R I P T I O N a 02.24.2023 L.L. b -- DRAWINGS PREPARED BY LUIS LOPEZ 03.02.2023 (714) 417-7771 OCBuildersGroup.com PL A N C H E C K N O . c -- 23 A WINDOW SYMBOL DOOR SYMBOL2 (N) 6 PAGE NUMBER SECTION NUMBER PAGE NUMBER DETAIL NUMBER 1 A A 1 (E) NEW KEY NOTES EXISTINGNEW WALL EXISTING WALL DEMO WALL W/ BATTERY BACKUP SMOKE DETECTOR, HARDWIREDSD W/ BATTERY BACKUP CARBON MONOXIDE, HARDWIREDCO 1ST FLOOR LEGEND NEW - 1st FLOOR PLAN SCALE 1/4" = 1'-0" NEW WINDOW SCHEDULE A SYM SIZE B SYMBOL: A TYPE C D NOTE DOOR SCHEDULE 1 SYM SIZE 2 SYMBOL: 1 TYPE 3 4 NOTE REQ'D. FOR ALL WINDOWS U-Factor : 0.30 MAX SHGC : 0.21 MAX STATUS U-Factor : 0.30 MAX SHGC : 0.21 MAX 11 HUNG 3'-0" X 6'-8"SOLID EXTERIOR DOOR 5 6 7 8 9 - STATUS 10 12 13 14 15 16 17 18 - E F G H I J K L M N O P Q R 4'-0" X 4'-0" 2'-6" X 5'-0"HUNG FIXED5'-0" X 5'-0" 2'-6" X 5'-0"HUNG 3'-0" X 4'-0"HUNG 3'-0" X 4'-0"FIXED 2'-6" X 2'-10"FIXED 3'-0" X 4'-0"FIXED 2'-0" X 3'-0"HUNG HC2'-6" X 6'-8" 2'-8" X 6'-8" 2'-8" X 6'-8" 2'-8" X 6'-8" 2'-4" X 6'-8" HC HC HC SOLID 3'-0" X 4'-0"HUNG CASEMN'T CASEMN'T 2'-0" X 5'-0" 2'-0" X 5'-0" 3'-0" X 4'-0"HUNG 4'-0" X 5'-0"FIXED EXST'G EXST'G EXST'G EXST'G EXST'G EXST'G EXST'G EXST'G TEMP TEMP EXST'G EXST'G EXST'G EXST'G EXST'G EXST'G NEW NEW EXST'G REPLC'D REPLC'D EXST'G NEW 16'-0" X 10'-0" NEW NEW NEW NEW NEW GARAGE DOOR SLIDING POCKET DOORSLIDING TEMP. GLASS TEMP. GLASSSLIDING 7'-0" X 6'-8" EXST'G 2'-0" X 3'-0"HUNG TEMP NEW NEW 2'-6" X 6'-8"NEW HC 2'-8" X 6'-8"HC NEW NEW 2'-8" X 6'-8"SOLID SOLID 2'-6" X 6'-8" GARAGE DOOR EXST'G GARAGE DOOR16'-0" X 7'-0"SOLID 2'-6" X 6'-8" HC 18 NEWHC 2'-6" X 6'-8"HC 2'-6" X 6'-8"HC 2'-6" X 6'-8" POCKET DOORSLIDING 2'-8" X 6'-8" 2'-6" X 6'-8" 4'-0" X 5'-0"FIXED NEWTEMP 4'-0" X 5'-0"FIXED NEWTEMP 4'-0" X 5'-0"FIXED NEWTEMP KEY NOTES 1 2 EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL BE CLEAR OF ANY OBSTRUCTION AND OPERATIONAL FROM INSIDE OF THE ROOM WITHOUT THE USE OF KEYS, TOOLS OR SPECIAL KNOWLEDGE. KITCHEN EXHAUST HOOD, 100 cfm MIN. ENERGY STAR RATED, INTERMITTENT OPERATION, WITH A 5" DIA. DUCT WITH 2 ELBOWS, (MAX LENGTH 15' ) WALLS ABOVE BATHTUBS WITH A SHOWER AND SHOWER COMPARTMENTS SHALL BE FINISHED WITH A NONABSORBENT SURFACE. SUCH WALL SURFACES SHALL EXTEND TO A HEIGHT OF NOT LESS THAN 6 FEET ABOVE THE FLOOR. (R307.2) EXHAUST DUCTS SHALL TERMINATE 3'-0" FROM OPENINGS INTO THE BUILDING ( CMC 504.5) EXISTING 1-HOUR FIRE RATED WALL TO BE MAINTAINED. MINIMUM 5/8" TYPE "X" DRYWALL ON GARAGE SIDE. AT EXTERIOR DOOR, A LANDING IS REQUIRED ON EACH SIDE. THE LANDING SHALL HAVE A WIDTH NOT LESS THAN THE WIDTH OF THE DOOR AND A MINIMUM OF 36" LENGTH. - AT OUT-SWINGING DOOR THERE SHALL NOT BE MORE THAN 1-1/2" STEP DOWN FROM DOOR THRESHOLD TO LANDING. - AT IN-SWINGING DOORS OTHER THAN THE REQUIRED EGRESS SHALL NOT BE MORE THAN 7-3/4" BELOW THE TOP OF THE THRESHOLD. CLOTHES DRYER MOISTURE EXHAUST DUCT MUST BE 4" IN DIAMETER AND LENGTH IS LIMITED TO 14' WITH 2 ELBOWS . THE DUCT LENGTH SHALL BE REDUCED BY 2' FOR EVERY ELBOW IN EXCESS OF TWO. 1-HR FIRE RATED WALL. 5/8" TYPE X DRYWALL AT GARAGE SIDE. 3 4 5 6 7 8 GENERAL NOTES 1.SETBACKS ARE MEASURED TO FACE OF FINISH. a a a 6 7 8 9 10 11 12 13 15 KL (E) LOFT 1ST FLOOR BELOW J M 5'-1" TO P.L.5'-1" TO P.L. 20 ' - 0 " T O P . L . 76 ' - 1 " T O P . L . WINDOW SCHEDULE A SYM SIZE B SYMBOL: A TYPE C D NOTE DOOR SCHEDULE 1 SYM SIZE 2 SYMBOL: 1 TYPE 3 4 NOTE REQ'D. FOR ALL WINDOWS U-Factor : 0.30 MAX SHGC : 0.21 MAX STATUS U-Factor : 0.30 MAX SHGC : 0.21 MAX 11 HUNG 3'-0" X 6'-8"SOLID EXTERIOR DOOR 5 6 7 8 9 - STATUS 10 12 13 14 15 16 17 18 - E F G H I J K L M N O P Q R 4'-0" X 4'-0" 2'-6" X 5'-0"HUNG FIXED5'-0" X 5'-0" 2'-6" X 5'-0"HUNG 3'-0" X 4'-0"HUNG 3'-0" X 4'-0"FIXED 2'-6" X 2'-10"FIXED 3'-0" X 4'-0"FIXED 2'-0" X 3'-0"HUNG HC2'-6" X 6'-8" 2'-8" X 6'-8" 2'-8" X 6'-8" 2'-8" X 6'-8" 2'-4" X 6'-8" HC HC HC SOLID 3'-0" X 4'-0"HUNG CASEMN'T CASEMN'T 2'-0" X 5'-0" 2'-0" X 5'-0" 3'-0" X 4'-0"HUNG 4'-0" X 5'-0"FIXED EXST'G EXST'G EXST'G EXST'G EXST'G EXST'G EXST'G EXST'G TEMP TEMP EXST'G EXST'G EXST'G EXST'G EXST'G EXST'G NEW NEW EXST'G REPLC'D REPLC'D EXST'G NEW 16'-0" X 10'-0" NEW NEW NEW NEW NEW GARAGE DOOR SLIDING POCKET DOORSLIDING TEMP. GLASS TEMP. GLASSSLIDING 7'-0" X 6'-8" EXST'G 2'-0" X 3'-0"HUNG TEMP NEW NEW 2'-6" X 6'-8"NEW HC 2'-8" X 6'-8"HC NEW NEW 2'-8" X 6'-8"SOLID SOLID 2'-6" X 6'-8" GARAGE DOOR EXST'G GARAGE DOOR16'-0" X 7'-0"SOLID 2'-6" X 6'-8" HC 18 NEWHC 2'-6" X 6'-8"HC 2'-6" X 6'-8"HC 2'-6" X 6'-8" POCKET DOORSLIDING 2'-8" X 6'-8" 2'-6" X 6'-8" 4'-0" X 5'-0"FIXED NEWTEMP 4'-0" X 5'-0"FIXED NEWTEMP 4'-0" X 5'-0"FIXED NEWTEMP SHEET REVISIONS BY 4 PLAN 2066 LUIS L. AS NOTED 02.24.2023 30 6 S A I N T A N D R E W S R D NE W P O R T B E A C H , C A 9 2 6 6 3 AP N : 0 4 9 - 2 3 0 - 1 1 TR A C T : 1 2 2 0 LO T : 4 4 DATE SCALE DRAWN JOB SHEET REVISIONS BY SHEET TITLE of sheets JO B A D D R E S S LE G A L D E S C R I P T I O N a 02.24.2023 L.L. b -- DRAWINGS PREPARED BY LUIS LOPEZ 03.02.2023 (714) 417-7771 OCBuildersGroup.com PL A N C H E C K N O . c -- 23 A WINDOW SYMBOL DOOR SYMBOL2 (N) 6 PAGE NUMBER SECTION NUMBER PAGE NUMBER DETAIL NUMBER 1 A A 1 (E) NEW KEY NOTES EXISTINGNEW WALL EXISTING WALL DEMO WALL W/ BATTERY BACKUP SMOKE DETECTOR, HARDWIREDSD W/ BATTERY BACKUP CARBON MONOXIDE, HARDWIREDCO 2ND FLOOR LEGEND SCALE 1/4" = 1'-0" EXISTING EXISTING / DEMO - 2ND FLOOR PLAN GENERAL NOTES 1.SETBACKS ARE MEASURED TO FACE OF FINISH. a a a a a KL BEDROOM 3 24'-0" 22 ' - 0 " 34 ' - 1 " 56 ' - 1 " J M OPEN TO BELOW 12 ' - 5 " 22 ' - 1 1 " 56 ' - 1 " 5' - 1 " 1' - 8 " 3'-11" 24'-0" BATH DN SHOWER 14 ' - 0 " 6'-5"8'-8" 5'-0" COSD SD 30 " M I N 24" MIN 4 18 4 16 19 17 1 3 CLOSET LANDING 42" HIGH GUARDRAIL Y 10 X 10 Y 10 X 10 4' - 5 " 19'-0" 5'-1" TO P.L.5'-1" TO P.L. 20 ' - 0 " T O P . L . 49 ' - 6 " T O P . L . DATE SCALE DRAWN JOB SHEET REVISIONS BY SHEET TITLE 5 PLAN 2066 LUIS L. AS NOTED 02.24.2023 30 6 S A I N T A N D R E W S R D NE W P O R T B E A C H , C A 9 2 6 6 3 AP N : 0 4 9 - 2 3 0 - 1 1 TR A C T : 1 2 2 0 LO T : 4 4 DATE SCALE DRAWN JOB SHEET REVISIONS BY SHEET TITLE of sheets JO B A D D R E S S LE G A L D E S C R I P T I O N a 02.24.2023 L.L. b -- DRAWINGS PREPARED BY LUIS LOPEZ 03.02.2023 (714) 417-7771 OCBuildersGroup.com PL A N C H E C K N O . c -- 23 JOB A WINDOW SYMBOL DOOR SYMBOL2 (N) 6 PAGE NUMBER SECTION NUMBER PAGE NUMBER DETAIL NUMBER 1 A A 1 (E) NEW KEY NOTES EXISTINGNEW WALL EXISTING WALL DEMO WALL W/ BATTERY BACKUP SMOKE DETECTOR, HARDWIREDSD W/ BATTERY BACKUP CARBON MONOXIDE, HARDWIREDCO 2ND FLOOR LEGEND NEW - 2ND FLOOR PLAN SCALE 1/4" = 1'-0" NEW WINDOW SCHEDULE A SYM SIZE B SYMBOL: A TYPE C D NOTE DOOR SCHEDULE 1 SYM SIZE 2 SYMBOL: 1 TYPE 3 4 NOTE REQ'D. FOR ALL WINDOWS U-Factor : 0.30 MAX SHGC : 0.21 MAX STATUS U-Factor : 0.30 MAX SHGC : 0.21 MAX 11 HUNG 3'-0" X 6'-8"SOLID EXTERIOR DOOR 5 6 7 8 9 - STATUS 10 12 13 14 15 16 17 18 - E F G H I J K L M N O P Q R 4'-0" X 4'-0" 2'-6" X 5'-0"HUNG FIXED5'-0" X 5'-0" 2'-6" X 5'-0"HUNG 3'-0" X 4'-0"HUNG 3'-0" X 4'-0"FIXED 2'-6" X 2'-10"FIXED 3'-0" X 4'-0"FIXED 2'-0" X 3'-0"HUNG HC2'-6" X 6'-8" 2'-8" X 6'-8" 2'-8" X 6'-8" 2'-8" X 6'-8" 2'-4" X 6'-8" HC HC HC SOLID 3'-0" X 4'-0"HUNG CASEMN'T CASEMN'T 2'-0" X 5'-0" 2'-0" X 5'-0" 3'-0" X 4'-0"HUNG 4'-0" X 5'-0"FIXED EXST'G EXST'G EXST'G EXST'G EXST'G EXST'G EXST'G EXST'G TEMP TEMP EXST'G EXST'G EXST'G EXST'G EXST'G EXST'G NEW NEW EXST'G REPLC'D REPLC'D EXST'G NEW 16'-0" X 10'-0" NEW NEW NEW NEW NEW GARAGE DOOR SLIDING POCKET DOORSLIDING TEMP. GLASS TEMP. GLASSSLIDING 7'-0" X 6'-8" EXST'G 2'-0" X 3'-0"HUNG TEMP NEW NEW 2'-6" X 6'-8"NEW HC 2'-8" X 6'-8"HC NEW NEW 2'-8" X 6'-8"SOLID SOLID 2'-6" X 6'-8" GARAGE DOOR EXST'G GARAGE DOOR16'-0" X 7'-0"SOLID 2'-6" X 6'-8" HC 18 NEWHC 2'-6" X 6'-8"HC 2'-6" X 6'-8"HC 2'-6" X 6'-8" POCKET DOORSLIDING 2'-8" X 6'-8" 2'-6" X 6'-8" 4'-0" X 5'-0"FIXED NEWTEMP 4'-0" X 5'-0"FIXED NEWTEMP 4'-0" X 5'-0"FIXED NEWTEMP KEY NOTES 1 2 EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL BE CLEAR OF ANY OBSTRUCTION AND OPERATIONAL FROM INSIDE OF THE ROOM WITHOUT THE USE OF KEYS, TOOLS OR SPECIAL KNOWLEDGE. KITCHEN EXHAUST HOOD, 100 cfm MIN. ENERGY STAR RATED, INTERMITTENT OPERATION, WITH A 5" DIA. DUCT WITH 2 ELBOWS, (MAX LENGTH 15' ) WALLS ABOVE BATHTUBS WITH A SHOWER AND SHOWER COMPARTMENTS SHALL BE FINISHED WITH A NONABSORBENT SURFACE. SUCH WALL SURFACES SHALL EXTEND TO A HEIGHT OF NOT LESS THAN 6 FEET ABOVE THE FLOOR. (R307.2) EXHAUST DUCTS SHALL TERMINATE 3'-0" FROM OPENINGS INTO THE BUILDING ( CMC 504.5) EXISTING 1-HOUR FIRE RATED WALL TO BE MAINTAINED. MINIMUM 5/8" TYPE "X" DRYWALL ON GARAGE SIDE. AT EXTERIOR DOOR, A LANDING IS REQUIRED ON EACH SIDE. THE LANDING SHALL HAVE A WIDTH NOT LESS THAN THE WIDTH OF THE DOOR AND A MINIMUM OF 36" LENGTH. - AT OUT-SWINGING DOOR THERE SHALL NOT BE MORE THAN 1-1/2" STEP DOWN FROM DOOR THRESHOLD TO LANDING. - AT IN-SWINGING DOORS OTHER THAN THE REQUIRED EGRESS SHALL NOT BE MORE THAN 7-3/4" BELOW THE TOP OF THE THRESHOLD. CLOTHES DRYER MOISTURE EXHAUST DUCT MUST BE 4" IN DIAMETER AND LENGTH IS LIMITED TO 14' WITH 2 ELBOWS . THE DUCT LENGTH SHALL BE REDUCED BY 2' FOR EVERY ELBOW IN EXCESS OF TWO. 3 4 5 6 7 GENERAL NOTES 1.SETBACKS ARE MEASURED TO FACE OF FINISH. a a a a a STUCCO FINISH TO MATCH EXISTING EXISTING STUCCO FINISH STUCCO FINISH TO MATCH EXISTING STUCCO FINISH TO MATCH EXISTING STUCCO FINISH TO MATCH EXISTING 20 ' - 1 " 12 ' - 3 " FIN. FLOOR FIN. GRADE TOP OF ROOF FIN. CEIL. NEW ASPHALT. ROOF SHINGLE BY G.A.F. CLASS "B" OR BETTER O/ 2- LAYER 15# FELT W/ 19" OVERLAP ICC-ESR-3267 22 ' - 9 " NATURAL GRADE TOP OF ROOF 7' - 7 " SILL PL. 7' - 0 " FIN. FLOOR FIN. CEIL. TO PL. 12 4 12 4 EXISTING ASPHALT. ROOF SHINGLE NEW ASPHALT. ROOF SHINGLE BY G.A.F. CLASS "B" OR BETTER O/ 2- LAYER 15# FELT W/ 19" OVERLAP ICC-ESR-3267 aa 120.40 PEAK ELEV 124.15 RIDGE ELEV 118.06 RIDGE ELEV a a a 124.15 RIDGE ELEV 101.4 NG 102.6 NG102.9 NG P.L. LOWEST POINT 22 ' - 9 " NATURAL GRADE TOP OF ROOF a 101.4 NG 102.6 NG P.L. LOWEST POINT P.L. REVISIONS BY 6 ELEVATIONS 2066 LUIS L. AS NOTED 02.24.2023 30 6 S A I N T A N D R E W S R D NE W P O R T B E A C H , C A 9 2 6 6 3 AP N : 0 4 9 - 2 3 0 - 1 1 TR A C T : 1 2 2 0 LO T : 4 4 DATE SCALE DRAWN JOB SHEET REVISIONS BY SHEET TITLE of sheets JO B A D D R E S S LE G A L D E S C R I P T I O N a 02.24.2023 L.L. b -- DRAWINGS PREPARED BY LUIS LOPEZ 03.02.2023 (714) 417-7771 OCBuildersGroup.com PL A N C H E C K N O . c -- 23 SCALE 1/4" = 1'-0"SOUTH ELEVATION SCALE 1/4" = 1'-0"NORTH ELEVATION VENT NOTE: 1.VENTILATION OPENINGS SHALL HAVE AT LEAST DIMENSION OF 1/16" MINIMUM AND 1/4" MAXIMUM (R806.1) S.F.D. ATTIC VENTILATION TOTAL 1,284 sq.in. 2202 AREAQTY.FREE AIR AREA ITEM 14 X 18 GABLE VENT 110 sq.in. 14 X 6 EAVE VENT 44 sq.in.6 800824 X 12 HALF ROUND DORMER 100 sq.in. = 7.95 SQ.FT. (required)150 11,192 X 1,192 SQ.FT. NEW ATTIC AREA 7.95 SQ.FT. x 144 sq.in/ SQ.FT. = 1144.32 sq.in. 264 GENERAL NOTES 1.SETBACKS ARE MEASURED TO FACE OF FINISH. a 14 ' - 8 " FIN. FLOOR STUCCO FINISH TO MATCH EXISTING 10 ' - 0 " EXISTING STUCCO FINISH FIN. GRADE FIN. CEIL. TOP OF DOOR 12 4 12 4 12 4 12 4 12 4 12 4 12 4 12 4 12 4 5'-1" TO P.L. 5'-1" TO P.L. 7' - 7 " FIN. FLOOR 7' - 0 " FIN. FLOOR FIN. CEIL. TOP PL. EXISTING ASPHALT. ROOF SHINGLE EXISTING ASPHALT. ROOF SHINGLE 124.15 RIDGE ELEV 118.06 RIDGE ELEV aa a a a a a 120.40 PEAK ELEV a a a a a a 120.40 PEAK ELEV 22 ' - 9 " TOP OF ROOF a 101.4 NG LOWEST POINT 22 ' - 9 " TOP OF ROOF a 101.4 NG LOWEST POINT 3'-1" P.L.P.L. 3'-1" P.L. 3'-1" 3'-1" SCALE 1/4" = 1'-0"EAST ELEVATION REVISIONS BY 7 ELEVATIONS 2066 LUIS L. AS NOTED 02.24.2023 30 6 S A I N T A N D R E W S R D NE W P O R T B E A C H , C A 9 2 6 6 3 AP N : 0 4 9 - 2 3 0 - 1 1 TR A C T : 1 2 2 0 LO T : 4 4 DATE SCALE DRAWN JOB SHEET REVISIONS BY SHEET TITLE of sheets JO B A D D R E S S LE G A L D E S C R I P T I O N a 02.24.2023 L.L. b -- DRAWINGS PREPARED BY LUIS LOPEZ 03.02.2023 (714) 417-7771 OCBuildersGroup.com PL A N C H E C K N O . c -- 23 SCALE 1/4" = 1'-0"WEST ELEVATION GENERAL NOTES 1.SETBACKS ARE MEASURED TO FACE OF FINISH. a NOT USED 4: 1 2 4: 1 2 4: 1 2 4: 1 2 4: 1 2 4: 1 2 4:124:12 4:12 4:12 4:12 4:12 4:12 4:12 4:124:12 4:12 EXISTING LOWER ROOF 4:12 4:12 4:12 4:12 NE W EX S T ' G NEW ASPHALT. ROOF SHINGLE BY G.A.F. CLASS "B" OR BETTER O/ 2- LAYER 15# FELT W/ 19" OVERLAP ICC-ESR-3267 5'-1" TO P.L.5'-1" TO P.L. 20 ' - 0 " T O P . L . 49 ' - 6 " T O P . L . 3'-1" NEW STUCCO UNDER EAVE NEW STUCCO UNDER EAVE 3'-1" 3'-1" a a a a a a a 3'-1" a 2 nails per step flashing Extend GAF leak barrier at least 5"(127mm) up wall. Extend GAF leak barrier at least 5"(127mm) up wall Place metal step flashing just upslope from exposed edge of shingle and extend 5" (127mm) over underlying shingle and 5" (127mm) up the vertical wall. Step flashing pieces overlap each other 2" (51mm) Cover metal flashing with cut shingle. Do NOT nail shingle, install with asphaltic plastic cement. Metal flashing (Nailed to the deck, NOT to the vertical wall) extend up wall at least 5" (127mm) Siding/cladding must be at least 2" (51mm) above the roof surface and covering flashing at least 2" (51mm). 13-1/4"(337mm) 11-5/8"-14-5/8" 39-3/8" These shingles MUST be nailed a nominal 6" (152mm) from bottom of of shingle, above the cut outs, as shown. Nails must not be exposed. 1/2" - 2-1/2" (13 - 64mm) 1/2" - 2-1/2" STANDARD NAILING PATTERN - four nails per shingle 5-3/4" - 6-1/4" (146mm - 159mm) from bottom of shingle 11-5/8"-14-5/8" DRAWN REVISIONS BY 8 2066 LUIS L. AS NOTED 02.24.2023 30 6 S A I N T A N D R E W S R D NE W P O R T B E A C H , C A 9 2 6 6 3 AP N : 0 4 9 - 2 3 0 - 1 1 TR A C T : 1 2 2 0 LO T : 4 4 DATE SCALE DRAWN JOB SHEET REVISIONS BY SHEET TITLE of sheets JO B A D D R E S S LE G A L D E S C R I P T I O N a 02.24.2023 L.L. b -- DRAWINGS PREPARED BY LUIS LOPEZ 03.02.2023 (714) 417-7771 OCBuildersGroup.com PL A N C H E C K N O . c -- 23 ROOF PLAN ROOF PLAN SCALE 1/4" = 1'-0"ROOFING INSTALLATION DETAIL SCALE NONE VENT NOTE: 1.VENTILATION OPENINGS SHALL HAVE AT LEAST DIMENSION OF 1/16" MINIMUM AND 1/4" MAXIMUM (R806.1) ROOFING NOTES: 1.COOL ROOF REQUIRED. THE THERMAL EMITTANCE AND AGED SOLAR REFLECTANCE VALUES OF THE ROOFING MATERIAL MUST MEET THE REQUIREMENTS OF SECTION 110.8(i) AND BE LABELED PER SECTION 10-113 OF THE CA. GREEN BUILDING CODE. 24" 12" ROOF OPENING FLANGEFLANGE GIBRALTAR BUILDING PRODUCTS ROOF OPENING FLANGE ROOF FLANGE FLANG E OPENIN G FRONT SIDE TOP DESCRIPTION 24 x 12 Square Tail DORMER VENT Height 12" Width 24" Rough Opening 12" x 9" N.F.V. 100 sq.in. GIBRALTAR BUILDING PRODUCTS DESCRIPTION EAVE VENT Height 6" Width 14" Rough Opening 14.25 x 5.75 N.F.V. 44 sq.in. FLAT BLOCK BLOCK EAVE VENT RAFTERS GIBRALTAR BUILDING PRODUCTS DESCRIPTION GABLE LOUVER Height 18" Width 14" Rough Opening 14.25 x 18.25 N.F.V. 110 sq.in. GALV. NAIL TYP. 1. FRAME ROUGH OPENING 2. VENT FASTENED TO FRAME 3. INSTALL WALL FINISH, STUCCO OR SIDING COSD COSD SD SD COSD COSD SD SD EXISTING ELECTRICAL TO REMAIN EXISTING ELECTRICAL TO REMAIN EXISTING ELECTRICAL TO REMAIN EXISTING ELECTRICAL TO REMAIN EXISTING ELECTRICAL TO REMAIN EXISTING ELECTRICAL TO REMAIN EXISTING ELECTRICAL TO REMAIN GFCI GFCI GFCI GFCI GFCI GFCI GFCI GFCI 3 COSD GFCI GFCI SD DATE SCALE DRAWN JOB SHEET REVISIONS BY SHEET TITLE 9 FLOOR PLAN 2066 LUIS L. AS NOTED 02.24.2023 30 6 S A I N T A N D R E W S R D NE W P O R T B E A C H , C A 9 2 6 6 3 AP N : 0 4 9 - 2 3 0 - 1 1 TR A C T : 1 2 2 0 LO T : 4 4 DATE SCALE DRAWN JOB SHEET REVISIONS BY SHEET TITLE of sheets JO B A D D R E S S LE G A L D E S C R I P T I O N a 02.24.2023 L.L. b -- DRAWINGS PREPARED BY LUIS LOPEZ 03.02.2023 (714) 417-7771 OCBuildersGroup.com PL A N C H E C K N O . c -- 23 JOB ELECTRICAL 1.ALL NEW BRANCH CIRCUITS THAT SUPPLY 125 VOLT,SINGLE PHASE, 15 AND 20 AMPERE RECEPTACLE OUTLETS INSTALLED IN FAMILY ROOM, DINING ROOM, LIVING ROOM, PARLORS, LIBRARY, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS OR SIMILAR ROOMS OR AREAS MUST BE PROTECTED BY ARC FAULT CIRCUIT INTERRUPTER BREAKER, COMBINATION TYPE. ( ARC-FAULT REQUIREMENT IS FOR ENTIRE CIRCUIT NOT JUST THE OUTLETS.) 2.ALL NEW BRANCH CIRCUITS THAT SUPPLY 125 VOLT, SINGLE PHASE, 15 AND 20 AMPERE REC 3.EPTACLE OUTLETS INSTALLED IN KITCHEN, BATHROOM, LAUNDRY AND GARAGE OR SIMILAR ROOMS OR AREAS MUST BE PROTECTED BY GROUND FAULT CIRCUIT INTERRUPTER BREAKER. 4.PROVIDE SEPARATE SWITCH FOR EXHAUST FAN. PER CAL ENERGY GOXE 150.0 (k) 2B. 5.IN BATHROOM, LAUNDRY ROOM, AND UTILITY ROOM, AT LEAST ONE LUMINAIRE IN EACH OF THESE SPACES SHALL BE CONTROLLED BY A VACANCY SENSOR. PER CEC 150.0 (k) 2J. 6.ALL INSTALLED LUMINAIRES SHALL BE HIGH-EFFICACY IN ACCORDANCE WITH TABLE 150 0-A, PER CAL ENERGY CODE. ELECTRICAL NOTES 1.SINGLE AND MULTIPLE STATION SMOKE ALARMS SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS: 1.1.IN EACH SLEEPING ROOM. 1.2.OUTSIDE OF EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. 1.3.ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDING BASEMENTS AND HABITABLE ATTICS, BUT NOT INCLUDING CRAWL SPACES AND UNINHABITABLE ATTICS. 2.SMOKE ALARMS SHALL BE HARDWIRED WITH BATTERY BACKUP AND ALARMS INTERCONNECTED. 3.BATTERY OPERATED SMOKE ALARMS ARE PERMITTED IN LIEU OF INTERCONNECTION / HARDWIRED OF SMOKE ALARMS IN EXISTING AREAS WHERE THE CONSTRUCTION DOES NOT INVOLVE THE REMOVAL OF INTERIOR FINISHES 4.AN APPROVED CARBON MONOXIDE ALARM SHALL BE INSTALLED OUTSIDE OF EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS AND ON EVERY LEVEL INCLUDING BASEMENT IN DWELLING UNITS THAT HAVE FUEL-FIRED APPLIANCES OR ATTACHED GARAGES. 5.BATTERY OPERATED CARBON MONOXIDE ALARM IS PERMITTED IN EXISTING AREAS WHERE THE CONSTRUCTION DOES NOT INVOLVE THE REMOVAL OF INTERIOR FINISHES. SMOKE AND CARBON ALARM NOTES ELECTRICAL - 1ST FLOOR PLAN SCALE 1/4" = 1'-0" DUPLEX OUTLET GROUND FAULT INTERUPTOR DUPLEX OUTLET ON SINGLE POLE LIGHT SWITCH W/ BATTERY BACKUP SMOKE DETECTOR, HARDWIREDSD EXHAUST FAN 50 CFM INTERMITTEN Controlled by humidistat CEILING MOUNTED LIGHT SINGLE POLE LIGHT SWITCH WITH DIMMER FAULT CIRCUIT INTERRUPTER DUPLEX OUTLET ON ARCAFCI FLOURECENT LIGHT FIXTURE 4" RECESSED LIGHT D W/ BATTERY BACKUP CARBON MONOXIDE, HARDWIREDCO LED TYPE FIXTURE, IC RATED HANGING LIGHT FIXTURE WALL MOUNTED LIGHT FIXTURE GFI WALL MOUNTED LIGHT FIXTURE HE LED TYPE LED TYPE, 15 WATT SINGLE POLE LIGHT SWITCH WITH VACANCY SENSOR VSWALL MOUNTED LIGHT FIXTURE W/ PHOTO CONTROL SENSORPS LEGEND - ELECTRICAL ELECTRICAL - 2nd FLOOR PLAN SCALE 1/4" = 1'-0" 1.FOR KITCHEN LIGHTING, 50% OF ALL WATTAGE MUST BE EFFICACY (E.G. FLOURECENT). THE HIGH EFFICACY FIXTURES AND NON-HIGH EFFICACY FIXTURES HAVE TO BE SWITCHED SEPERATELY . ANY AREAS ADJACENT TO THE KITCHEN ON THE SAME LIGHT SWITCH ARE CONSIDERED PART OF THE KITCHEN. THIS MUST BE DOCUMENTED IN THE REPORT THAT IS SUBMITTED TO THE BUILDING DEPARTMENT. 2. LIGHTING IN BATHROOMS, GARAGES, LAUNDRY ROOMS, AND/ OR UTILITY ROOMS MUST BE HIGH EFFICACY OR MJST BE CONTROLLED BY A MANUAL- ON OCCUPANCY SENSOR. A MANUAL- ON OCCUPANCY SENSOR MUST BE MANUALLY TURNED ON AND AS LONG AS THE SENSOR DETECTS MOVEMENT STAYS ON. WHEN MOVEMENT IS NOT DETECTED, WHICH CANNOT BE LONGER THAN 30 MIN. THE FIXTURE AUTOMATICALLY TURNS OFF. A BATHROOM IS DEFINED AS A ROOM CONTAINING A SHOWER, TUB, TOILET, OR SINK THAT IS USED FOR PERSONAL HYGENE. SO THIS WOULD INCLUDE A VANITY SINK IN A DRESSING AREA OR PERHAPS EVEN IN THE BEDROOM, WHICH WOULD REQUIRE A HIGH EFFICACY LIGHT SERVING THAT SPECIFIC AREA. 3.ALL PERMANENTLY INSTALLED LIGHTING IN OTHER ROOMS, INCLUDING HALLWAYS, DINING ROOMS, BEDROOMS, FAMILY ROOMS, MUST BE HIGH EFFICACY LIGHT SERVICES OR CONTROLLED BY A MANUAL-ON OCCUPANCY SENSOR, OR A DIMMER. THE MANUAL-ON OCCUPANCY SENSORS ARE BEING MANUFACTURER AND ARE AVAILABLE. THE EXCEPTION IS A CLOSET UNDER 70 SQUARE FEET, AND HALF HOT OUTLES FOR LAMPS. 4.RECESSED LIGHTS ARE TO BE INSTALLED IN AN INSULATED CEILING OR CAVITY ARE REQUIRED TO HAVE A ZERO CLEARANCE INSULATION COVER (IC): BE CERTIFIED THAT THEY ARE AIR TIGHT : AND SEALED WITH A GASKET OR CAULK BETWEEN THE HOUSING AND THE CEILING. 5.OUTDOOR LIGHTING THAT IS ATTACHED TO A BUILDING MUST BE HIGHT EFFICACY, OR CONTROLLED BY A MOTION SENSOR WITH AN INTEGRAL PHOTOCONTROL. LIGHTING AROUND SWIMMING POOL S, WATER FEATURES, OR OTHER LOCATIONS SUBJECT TO ARTICLE 680 OF THE CALIFORNIA ELECTRIC CODE ARE EXEMPT. LIGHTING LIGHT FIXTURE CONTROLLED BY SWITCH NEAR ATTIC ACCESS 'B' VENT THRU ROOF (AS REQUIRED) 110v OUTLET SECTION 319.3) ACCESS (PER U.M.C. 30"x30" ATTIC SPECIFIED IN THE LISTING CLEARANCES SHALL BE AS ON COMBUSTIBLE FLOORING- F.A.U. SHALL BE LISTED FOR INSTALLATION IN ATTICS AND 26 GA. x 1" WIDE GALV. MTL. STRAP (1 EACH WAY) FOR ENTIRE LENGTH OF UNIT LEVEL WORKING PLATFORM 5/8" THK. 'CDX' PLYWOOD DISTANCE) WAY (20'-0" MAX. TRAVEL 'CDX' PLYWOOD PASSAGE 5/8" THK. x 24" MIN. WIDE 24" MIN . W I D E PASSA G E W A Y 30" MIN . 5' - 0 " M I N DBL. BLK'G OR JOIST BELOW UNIT AND AT 30x30 ACCESS POSITIVE ELECTRICAL DISCONNECTION ATTIC FORCED AIR UNIT A GARAGE DOOR IS TO COMPLY WITH THE AUTOMATIC GARAGE DOOR OPENERS IN THE 2019 CALIFORNIA RESIDENTIAL CODE. KEY NOTES (N) FOOTING (N) FOOTING (N) 2x8 @ 16"oc R-19 INSUL (E) 2x4 @ 16"oc (N) R.R. (N) C.J.R-30 INSUL (E) FOOTING R-30 INSUL (N) FOOTING (N) FOOTING R-19 INSUL (N) 2x6 @ 16"oc R-19 INSUL (N) 2x6 @ 16"oc (N) RIDGE (N) R.R. (N) R.R. R-30 INSUL R-30 INSUL (N) BEAM (N) C.J.R-30 INSUL (N) SLAB (E) FOOTING 7' - 8 " (N) 2x4 @ 16"oc (N) F.J. (E) F.J. 14 ' - 8 " 14 ' - 8 " WALL REMOVED ROOF SECTION REMOVED (N) 2x4 @ 16"oc DATE SCALE DRAWN JOB SHEET REVISIONS BY SHEET TITLE 10 SECTIONS 2066 LUIS L. AS NOTED 02.24.2023 30 6 S A I N T A N D R E W S R D NE W P O R T B E A C H , C A 9 2 6 6 3 AP N : 0 4 9 - 2 3 0 - 1 1 TR A C T : 1 2 2 0 LO T : 4 4 DATE SCALE DRAWN JOB SHEET REVISIONS BY SHEET TITLE of sheets JO B A D D R E S S LE G A L D E S C R I P T I O N a 02.24.2023 L.L. b -- DRAWINGS PREPARED BY LUIS LOPEZ 03.02.2023 (714) 417-7771 OCBuildersGroup.com PL A N C H E C K N O . c -- 23 JOB SECTION SCALE 3/8" = 1'-0"YSECTIONSCALE 3/8" = 1'-0"X L=9' L= 1 2 ' 11 4x 6 P O S T W/ H D U 4 4x 6 P O S T W/ H D U 4 WSWH24x14 WSWH24x14 WS W H 2 4 x 1 4 Y 10Y10Y10 X 10 X 10 X 10 Y 10Y10Y10 X 10 X 10 X 10 B 11 A 11 A 11 A 11 D 9 C 11 D 9 B 11 A 11 A 1 B D EC 2 4 3 4. 3 4x6 POST 4x6 POST 5 6 3X SILL PLATE EXISTING RAISED-FLOOR FOUNDATION (E) FOOTING 12" W. x 12" DEEP W/ #4 TOP AND BOT EXISTING RAISED-FLOOR FOUNDATION (E) FOOTING 12" W. x 12" DEEP W/ #4 TOP AND BOT (E) FOOTING 12" W. x 12" DEEP W/ #4 TOP AND BOT (E) FOOTING 12" W. x 12" DEEP W/ #4 TOP AND BOT (E) FOOTING 12" W. x 12" DEEP W/ #4 TOP AND BOT (E) FOOTING 12" W. x 12" DEEP W/ #4 TOP AND BOT 2'-0" X 2'-0" X 15" THK. CONC. PAD W/ 4-#4 EACH WAY 2'-0" X 2'-0" X 15" THK. CONC. PAD W/ 4-#4 EACH WAY 3'-0" X 3'-0" X 15" THK. MIN. CONC. PAD W/ 6-#4 EACH WAY 2'-6" X 2'-6" X 15" THK. MIN. CONC. PAD W/ 5-#4 EACH WAY 3'-0" X 4'-0" X 36" THK. IN DEPTH CONC. PAD W/ 3-#4 TOP AND BOTTOM W/ #3 STIRRUPS @6"o.c. 3'-0" X 4'-0" X 36" THK. IN DEPTH CONC. PAD W/ 3-#4 TOP AND BOTTOM W/ #3 STIRRUPS @6"o.c. 3'-0" X 4'-0" X 36" THK. IN DEPTH CONC. PAD W/ 3-#4 TOP AND BOTTOM W/ #3 STIRRUPS @6"o.c. 22 ' - 0 " 24'-0" 2'-6" X 2'-6" X 15" THK. MIN. CONC. PAD W/ 5-#4 EACH WAY C 11 D 11 C 11 2- #4 TOP AND BOT 6" EMBED W/ SIMPSON SET-XP 2- #4 TOP AND BOT 6" EMBED W/ SIMPSON SET-XP 4x4 POST 4x4 POST 2 - 4x6 POST 1 15115 58" THREADED ROD 6" EMBED W/ SIMPSON SET EPOXY SEE FOUND. PLAN 4x POST SEE PLAN EXISTING CONT. FOOTING (E) 2x4 SILL 24 " M I N . SEE PLAN (N) CONC. PAD SIMPSON ABA OR HOLDOWN ( SEE PLAN ) REBAR PER PAD SCHED. 3" 3"3" 12 " 4x BLK'G 4X4 . POST SEE PLAN 18 " M I N 3" AND SCHEDULE RE-BAR SEE PLAN SIMPSON CBS44 4X4 . POST (E) F.J.2- 2x BLK'G (N) LTP4 WEEP SCREED 12" MIN 8" 18 " M I N . #3 DOWELS @ 24"OC EXTENDED 36" INTO SLAB 12" INTO FOOTING 2X4 @ 16OC STUD WALL 2X4 P.T. SILL W/ 5/8" X 10" A.B. @ 6' O.C. W/ 3" X 3" X 1/4" PLATE WASHERS 4" CONC. SLAB W/ #4@16"OC EA.WAY. SHT'G WHERE OCCURS (SEE SHEAR SCHED FOR NAILING PATTERN) MI N 2- #4 TOP AND BOT. 2" SAND CONC. SLAB. 2x_ STUDS @ 16"OC 2x P.T. SILL PLATE W/ RAMSET SHOTPINS @ 32"oc 1524-SDB (ICC ESR-2690) 1ST 2 PINS PLACED 6" AND 10" FROM PLATE END NON-BEARING WALL SILL PLATE SEE SHEAR SCHED. 2X4 STUD 5/8" X 10" A.B. SHEARWALL HOLDOWN PER PLAN NAILING PER SCHEDULE 15/32" STRUCT. 1 PLYWOOD OR OSB SIMPSON SSTB-16 NEW FOOTING 3 x 3 x 1/4 PLATE WASHER POST PER PLAN SEE PLAN 15 " M I N 3" RE-BAR SEE PLAN 5/8" x 12" A.B. CENTERED TO POST 4x4 POST 2x4 P.T. SILL CONC. SLAB SEE PLAN 3-1/2" CONC. SLAB W/ #3 @ 24" oc #3 W/ 3" COVER 10" MIN 7. 7 5 " 8" 7. 7 5 " MA X . MA X . 6" #3 DOWEL @ 24"oc 4" EMBED. TO FOOTING SEE DETAIL "C" FOR FOOTING DETAILS FILL WITH COMPACTED DIRT 36" MIN. 1" MAX STEP DOWN #3 DOWEL @ 32" OC 4" EMBEDMENT TO (E) FOOTING 2" CLEAN SAND, OVER 6 MILS VISQUINE, OVER 4" THK. CONC. SLAB W/ #4 @ 16" BOTH WAYS 2" CLEAN SAND 2' EXTENDED INTO NEW SLAB EXISTING WALL REMOVED EXISTING F.J. EXISTING FOOTING GALV. SHEET METAL (E) CRAWL SPACE 1' - 6 " #4 DOWELS TOP AND BOTTOM DRILL 7/8" dia. HOLE, CLEAN AND FILL HALFWAY W/ SIMPSON SET EPOXY ADHESIVE, INSERT BAR UNTIL HITS BOTTOM OF HOLE NEW CONC. FOOTING NEW 2- #4 CONT. REBAR TOP AND BOTTOM EXISTING CONC. FOOTING 6" SPECIAL INSPECTION REQ'D. DATE SCALE DRAWN SHEET REVISIONS BY SHEET TITLE 11 FOUNDATION 2066 LUIS L. AS NOTED 02.24.2023 30 6 S A I N T A N D R E W S R D NE W P O R T B E A C H , C A 9 2 6 6 3 AP N : 0 4 9 - 2 3 0 - 1 1 TR A C T : 1 2 2 0 LO T : 4 4 DATE SCALE DRAWN JOB SHEET REVISIONS BY SHEET TITLE of sheets JO B A D D R E S S LE G A L D E S C R I P T I O N a 02.24.2023 L.L. b -- DRAWINGS PREPARED BY LUIS LOPEZ 03.02.2023 (714) 417-7771 OCBuildersGroup.com PL A N C H E C K N O . c -- 23FOUNDATION PLAN SCALE 1/4" = 1'-0" 5/8" AB @ 48" O.C.16d @ 6" O.C. 5/8" AB @ 32" O.C. 5/8" AB @ 24" O.C. 5/8" AB @ 16" O.C. 5/8" AB @ 16" O.C. 5/8" AB @ 8" O.C. 16d @ 5" O.C. 5/16" Lag @ 8" O.C. 5/16" Lag @ 6" O.C. 5/16" Lag @ 4" O.C. 5/16" Lag @ 8" O.C. 15/32" STR I PLYWD BLKD W/8d @ 6" O.C. E.N. & 12" O.C. F.N. 15/32" STR I PLYWD BLKD W/10d @ 4" O.C. E.N. & 12" O.C. F.N. 15/32" STR I PLYWD BLKD W/10d @ 3" O.C. E.N. & 12" O.C. F.N. 15/32" STR I PLYWD BLKD W/10d @ 2" O.C. E.N. & 12" O.C. F.N. 15/32" STR I PLYWD BLKD w/10d @ 6"O.C. E.N. & 12"O.C. F.N. 15/32" STR I PLYWD BLKD W/8d @ 4" O.C. E.N. & 12" O.C. F.N. TOP SIMPSON A35/LTP4 16" O.C. CONCRETE & MASONRY WALL SHEATHING (2)SYM SHEAR 10 280 WOOD SILL CONNECTION SHEAR WALL SCHEDULE 16" O.C. 12" O.C. 8" O.C. 8" O.C. 12" O.C. 11 12 1 1 340 430 13 1 15 1 14 665 870 510 CALIFORNIA BUILDING CODE (2019)ANCHOR SHEAR-WALL KEY NOTES: 1.USE 3x STUDS, AND 3x BOTTOM PLATE WITH STAGGERED NAILING WHERE THE ALLOWABLE SHEAR VALUE EXCEEDS 350 PLF. 2.WHERE SHEAR MATERIAL IS INSTALLED ON BOTH SIDES, THE SPACING FOR THE ABOVE TOP ANCHORAGE AND SILL CONNECTION SHALL BE HALF SHOWN. UNLESS OTHERWISE NOTED ON PLANS. SHEAR-WALL NOTES: A.ALL EXTERIOR WALL TO BE SECURED WITH 5/8" DIAM. X 16"A.b.'S AT 72" O.C. WITH 7" EMBED., UNLESS OTHERWISE NOTED, AND WITH MINIMUM 3"x3"x1/4" THICK PLATE WASHER UNDER NUT AT EACH BOLT. B.ALL INTERIOR WALLS WITH SHOT PINS; RAMSET # 3348, OR EQUIVALENT, AT 36" O.C. AT BEARING WALLS AND 48" O.C. AT NON-BEARING WALLS, UNLESS OTHERWISE NOTED. C.CODE MINIMUM (2) ANCHOR BOLTS PER PANEL. D.CODE MINIMUM 16d SOLE PLATE NAILS AT 16" O.C. TYPICAL AT ALL WOOD FRAMED FLOOR WALLS (U.O.N.). E.WHERE DOUBLE 2x SOLE PLATES ARE USED, PROVIDE PROGRESSIVE NAILING. F.ALL NAILS ARE COMMON NAILS. G.TABLE FOR USE WITH STUDS AT 16" O.C. MAXIMUM. H.ALL LAG BOLTS (LB) TO BE 6" LONG INSTALLED WITH PILOT HOLE AND WRENCH. J.5/8" DIAM. A.B. MAY BE REPLACED BY 5/8" DIAM. THREADED RODS BY 5" EMBED. WITH SIMPSON ET EPOXY, ICBO ER 4945, (OR EQUIVALENT) AT THE SAME SPACING, WITH SPECIAL INSPECTION. EACH BOLT SHALL HAVE MIN. 3"x3"x1/4" THICK SQUARE WASHER. K.FRAMING MEMBERS OR BLOCKING SHALL BE PROVIDED AT ALL EDGES OF ALL PLYWOOD SHEETS IN SHEAR WALL. ROOF PLYWOOD DIAPHRAGM (ROOF SHEATHING) USE 15/32" STRUCTURAL C-D OR C-C PLYWOOD, MIN. PANEL INDEX NUMBER (24/16),W/ 8d NAILS AT 6" O.C. SUPPORTED EDGES AND BOUNDARIES; AT 12" O.C. IN THE FIELD (UNBLOCKED U.N.O.). FACE GRAIN OF PLYWOOD SHALL BE PERPENDICULAR TO SUPPORTS. FLOOR DECK PLYWOOD DIAPHRAGM (FLOOR SHEATHING) USE 19/32" STRUCTURAL, C-D, OR C-C PLYWOOD, MIN. PANEL INDEX NUMBER (32/16) TONGUE & GROOVE, WITH 10d NAILS AT 6" O.C. SUPPORTED EDGES AND BOUNDARIES; AT 10" O.C. IN THE FIELD (UNBLOCKED U.N.O.) FACE GRAIN OF PLYWOOD SHALL BE PERPENDICULAR TO SUPPORTS. NOT USED SCALE 3/4" = 1'-0"G SCALE 3/4" = 1'-0"B SCALE 3/4" = 1'-0"DFSCALE 3/4" = 1'-0" SCALE 3/4" = 1'-0"ASCALE 3/4" = 1'-0"C ESCALE 3/4" = 1'-0"CONCRETE PADNOT USED SLAB CONNECTIONCONC. PAD FOOTING CONNECTION EXTERIOR FOOTING (E) HDR (E) HDR (E) HDR (E) HDR (E) BEAM (E) HDR (E) HDR (E) HDR (E) HDR (E ) H D R (E) HDR (E) HDR (E) HDR (E) HDR(E) HDR (E) HDRB6 4X8 (E) HDR (E ) B E A M (E ) H D R (E ) H D R (E ) H D R (E ) H D R (E ) H D R (E ) H D R (E ) H D R B2 B4 4-1.75 X 9.25 PSL2.0E (E ) C . J . 2x 6 @ 1 6 " o c (E ) C . J . (E ) C . J . (E ) C . J . (E ) C . J . (E ) C . J . (E) C.J. (E) F.J. 2x12 @ 16"oc (E ) R . R . (E ) R . R . (E) R.R.(E) R.R. (N) R.R. 2x6 @ 16"oc (N) R.R. 2x6 @ 16"oc (E) R.R. 2x6 @ 16"oc (E ) H D R B5 4 X 1 0 (N ) H D R 4X6 4X6 (N ) H D R (N ) H D R 4X12 4X 6 (N) F.J. 2x6 @ 16"oc B3 4 X 1 2 L=9' 14 L= 1 2 ' 11 4x 6 P O S T W/ H D U 4 (N ) F . J . 4x 1 2 @ 1 6 " o c OPEN TO BELOW 4x 6 P O S T W/ H D U 4 WSWH24x14 WSWH24x14 WS W H 2 4 x 1 4 4x6 KING POST ABOVE Y 10Y10Y10 X 10 X 10 X 10 Y 10Y10Y10 X 10 X 10 X 10 D 9 D 9 4X 1 2 4X 1 2 4X12 AA 1 BB DD EECC 2 4 3 4. 3 4x6 POST 4x6 POST 4x6 KING POST ABOVE MST37 5 6 3X SILL PLATE 2X 6 @ 1 6 " o . c . B A L L O O N F R A M E W/ SDS SCREWS MICROLAM LVL TOP AND BOTTOM @6"o.c. STAGGERED 4x4 POST W/ HDU8 4x4 POST W/ HDU8 A 12 A 12 B 12 B 12 C 12C12 G 12 TR E L L I S J O I S T 2x 4 @ 1 6 " o c TRELLIS TOP JOIST 2x2 @ 16"oc 4x4 POST 4x4 POST 7 X 9.5 PSL2.0E W/ ECC W/ ECC 2 - 4x6 POST (E) RIDGE (E) RIDGE 1-HR. FIRE PROTECTION UNDER STAIRS 5/8" TYPE X GYP. BD. 2X BLK'G. DBL. JOIST OR HEADER 2X14 STRINGER (3-MIN.) SEE STRUCTURAL SHEET S-1 6' - 8 " M I N LESS THAN 4" 3/4" PLYWOOD TREADS & RISERS 12 34 " - 3 8 " H I G H 6" 6 " 3/4" PLYWOOD TREADS & RISERS LESS THAN 6" DIA. 11" 7" TYP. D 12 D KEY NOTES: 1.MAXIMUM DIFFERENCE BETWEEN THE STAIR RISERS AND TREADS SHALL NOT BE GREATER THAN 3/ 8" 2.HANDRAILS SHALL BE CONTINUOUS EXCEPT AT A TURN THEY ARE PERMITTED TO BE INTERRUPTED BY A NEWEL POST AND HAVE A MINIMUM CLEAR DISTANCE BETWEEN THE WALL AND HANDRAIL GRIP OF 1- 1 /2" 3.7.75" MAX RISER AND 10" MIN TREAD 36" MIN (7 . 7 5 " M A X ) 10" MIN TOP OF RAIL 4' MAX LESS THAN 4" 42 " M I N . DECK FLOOR 4"Ø SPHERE MUST NOT PASS THROUGH TYPICAL 1/8"TYP 1/8"TYP TOP RAIL 1 1/2" x 1 1/2" x 1/8" SQ. TUBING 1" x 1" x 1/8" SQ. TUBING BOT. RAIL 1 1/2" x 1 1/2" x 1/8" SQ. TUBING 12 D TYP. 2X F.J. (SEE PLAN) 19/32" PLY. W/ 10d @ 6"/6"/12" 2X4 SILL 2X4 @ 16"OC STUD WALL R-13 BATT. INSUL. 16d @ 8" OC 2-2X4 PLATE 2X4 @ 16"OC STUD WALL SIMPSON A35 @ 32" OC U.N.O. ON SHEAR SCHED 2X BLK'G. B.N. B.N. 2-2X4 PLATE SIMPSON A35 @ 32" OC U.N.O. ON SHEAR SCHED 2X4 @ 16"OC STUD WALL 2X4 SILL 2X4 @ 16"OC STUD WALL 2X F.J. (SEE PLAN) 16d @ 8" oc 19/32" PLY. OR OSB W/ 10d @ 6/6/12 B.N. B.N. WALL REMOVED (E) FLR. SHT'G. (E) FLR. JOIST (E) STUD WALL (N) FLR. SHT'G. B.N. (E) B.N. (N) FLR. JOIST LUS HANGER 2x6 LEDGER W/ 1/2" x 5" LAG AT 16" oc A35 @ 16"oc 1/8"2- 1/2"DIA x 4" LAG SCREWS 5" 112"112" 3"3" 4" 2- 2x BLK OR 2- JOIST 2- 2x BLK OR JOIST 1 1/2" x 1 1/2" x 1/8" SQ. TUBING 2- 1/2" x 3" LAG BOLTS 4x4x1/4 STEEL ANGLE 4" 4" 1/8" BOT. RAIL 2X STUD 4-12 LAGS @ SUPPORTS 2X4 BLK'G 11 4"MIN. , 2" MAX 212" (11 2 MIN) MIN. 0.1 RADIUS SHEET REVISIONS BY 12 SECOND FLOOR 2066 LUIS L. AS NOTED 02.24.2023 30 6 S A I N T A N D R E W S R D NE W P O R T B E A C H , C A 9 2 6 6 3 AP N : 0 4 9 - 2 3 0 - 1 1 TR A C T : 1 2 2 0 LO T : 4 4 DATE SCALE DRAWN JOB SHEET REVISIONS BY SHEET TITLE of sheets JO B A D D R E S S LE G A L D E S C R I P T I O N a 02.24.2023 L.L. b -- DRAWINGS PREPARED BY LUIS LOPEZ 03.02.2023 (714) 417-7771 OCBuildersGroup.com PL A N C H E C K N O . c -- 23LEVEL 2 FLOOR (LEVEL 1 WALLS) - FRAMING PLAN SCALE 1/4" = 1'-0" SCALE 3/4" = 1'-0"B SCALE 3/4" = 1'-0"EGUARDRAIL SCALE 3/4" = 1'-0"A SCALE 3/4" = 1'-0"DRAIL POST CONN. WALL TO FLOOR SCALE 3/4" = 1'-0"FHANDGRIP 5/8" AB @ 48" O.C.16d @ 6" O.C. 5/8" AB @ 32" O.C. 5/8" AB @ 24" O.C. 5/8" AB @ 16" O.C. 5/8" AB @ 16" O.C. 5/8" AB @ 8" O.C. 16d @ 5" O.C. 5/16" Lag @ 8" O.C. 5/16" Lag @ 6" O.C. 5/16" Lag @ 4" O.C. 5/16" Lag @ 8" O.C. 15/32" STR I PLYWD BLKD W/8d @ 6" O.C. E.N. & 12" O.C. F.N. 15/32" STR I PLYWD BLKD W/10d @ 4" O.C. E.N. & 12" O.C. F.N. 15/32" STR I PLYWD BLKD W/10d @ 3" O.C. E.N. & 12" O.C. F.N. 15/32" STR I PLYWD BLKD W/10d @ 2" O.C. E.N. & 12" O.C. F.N. 15/32" STR I PLYWD BLKD w/10d @ 6"O.C. E.N. & 12"O.C. F.N. 15/32" STR I PLYWD BLKD W/8d @ 4" O.C. E.N. & 12" O.C. F.N. TOP SIMPSON A35/LTP4 16" O.C. CONCRETE & MASONRY WALL SHEATHING (2)SYM SHEAR 10 280 WOOD SILL CONNECTION SHEAR WALL SCHEDULE 16" O.C. 12" O.C. 8" O.C. 8" O.C. 12" O.C. 11 12 1 1 340 430 13 1 15 1 14 665 870 510 CALIFORNIA BUILDING CODE (2019)ANCHOR SHEAR-WALL KEY NOTES: 1.USE 3x STUDS, AND 3x BOTTOM PLATE WITH STAGGERED NAILING WHERE THE ALLOWABLE SHEAR VALUE EXCEEDS 350 PLF. 2.WHERE SHEAR MATERIAL IS INSTALLED ON BOTH SIDES, THE SPACING FOR THE ABOVE TOP ANCHORAGE AND SILL CONNECTION SHALL BE HALF SHOWN. UNLESS OTHERWISE NOTED ON PLANS. SHEAR-WALL NOTES: A.ALL EXTERIOR WALL TO BE SECURED WITH 5/8" DIAM. X 16"A.b.'S AT 72" O.C. WITH 7" EMBED., UNLESS OTHERWISE NOTED, AND WITH MINIMUM 3"x3"x1/4" THICK PLATE WASHER UNDER NUT AT EACH BOLT. B.ALL INTERIOR WALLS WITH SHOT PINS; RAMSET # 3348, OR EQUIVALENT, AT 36" O.C. AT BEARING WALLS AND 48" O.C. AT NON-BEARING WALLS, UNLESS OTHERWISE NOTED. C.CODE MINIMUM (2) ANCHOR BOLTS PER PANEL. D.CODE MINIMUM 16d SOLE PLATE NAILS AT 16" O.C. TYPICAL AT ALL WOOD FRAMED FLOOR WALLS (U.O.N.). E.WHERE DOUBLE 2x SOLE PLATES ARE USED, PROVIDE PROGRESSIVE NAILING. F.ALL NAILS ARE COMMON NAILS. G.TABLE FOR USE WITH STUDS AT 16" O.C. MAXIMUM. H.ALL LAG BOLTS (LB) TO BE 6" LONG INSTALLED WITH PILOT HOLE AND WRENCH. J.5/8" DIAM. A.B. MAY BE REPLACED BY 5/8" DIAM. THREADED RODS BY 5" EMBED. WITH SIMPSON ET EPOXY, ICBO ER 4945, (OR EQUIVALENT) AT THE SAME SPACING, WITH SPECIAL INSPECTION. EACH BOLT SHALL HAVE MIN. 3"x3"x1/4" THICK SQUARE WASHER. K.FRAMING MEMBERS OR BLOCKING SHALL BE PROVIDED AT ALL EDGES OF ALL PLYWOOD SHEETS IN SHEAR WALL. ROOF PLYWOOD DIAPHRAGM (ROOF SHEATHING) USE 15/32" STRUCTURAL C-D OR C-C PLYWOOD, MIN. PANEL INDEX NUMBER (24/16),W/ 8d NAILS AT 6" O.C. SUPPORTED EDGES AND BOUNDARIES; AT 12" O.C. IN THE FIELD (UNBLOCKED U.N.O.). FACE GRAIN OF PLYWOOD SHALL BE PERPENDICULAR TO SUPPORTS. FLOOR DECK PLYWOOD DIAPHRAGM (FLOOR SHEATHING) USE 19/32" STRUCTURAL, C-D, OR C-C PLYWOOD, MIN. PANEL INDEX NUMBER (32/16) TONGUE & GROOVE, WITH 10d NAILS AT 6" O.C. SUPPORTED EDGES AND BOUNDARIES; AT 10" O.C. IN THE FIELD (UNBLOCKED U.N.O.) FACE GRAIN OF PLYWOOD SHALL BE PERPENDICULAR TO SUPPORTS. AND LOWER ROOF FRAMING SCALE 3/4" = 1'-0"CWALL TO FLOOR SCALE 3/4" = 1'-0"GSTAIR SCALE 3/4" = 1'-0"HNOT USED WALL TO FLOOR 2x_ R.R. @ 16" o.c. (SEE FRAMING)ROOF PITCH (SEE PLAN) ROOF SHEATHING, SEE PLAN B.N. 2x_ FASCIA (SEE ELEV.) 2x4 @ 16"o.c. STUD WALL A-35 @ 16"o.c. 2-2x4 TOP PLATE 2x_ C.J. @ 16"o.c. (SEE FRAM'G PLAN)B.N. 5-16d SHT'G WHERE OCCURS (SEE SHEAR SCHED FOR NAILING PATTERN) ROOF PITCH (SEE PLAN) SIMPSON LSTA-24 STRAP @ 48" OCB.N. 2x RAFTERS @ 16"OC (SEE FRAM'G PLAN) 2x RIDGE BOARD (SEE PLAN) 3 - 10d COMMON TOE NAILS EA. RAFTER 2x4 COLLAR TIE @48" oc W/ 3- 16d EA. END EXISTING ROOF SHEATH EXISTING R.R. A-35@16"oc A-35@16"oc BLK'G @ 48" OC EXISTING C.J. EXISTING STUD WALL SHEARWALL WHERE OCCURS SEE FRAMING PLAN B.N. B.N. SHT'G SAME AS BELOW (N) R.R. (N) C.J. B.N. FRONT VIEW TOP VIEW B.N. ROOF SHT'G 5- 1.75 x 14 2.0 E MICROLAM LVL W/ SDS SCREWS @ 12" oc 2" FROM TOP AND BOT R.R. SEE PLAN LUS HANGERS LUS HANGERS R.R. SEE PLAN C.J. SEE PLAN LSTA24 4x6 POST 4x6 POST 5- 1.75 x 14 2.0 E MICROLAM LVL W/ SDS SCREWS @ 12" oc 2" FROM TOP AND BOT 5- 1.75 x 14 2.0 E MICROLAM LVL W/ SDS SCREWS @ 12" oc 2" FROM TOP AND BOT 4x6 POST BELOW TOP PL LSTA24 A35 2x4 @ 16"o.c. STUD WALL A-35 @ 16"o.c. 2-2x4 TOP PLATE FASCIA TO MATCH EXST'G SHT'G WHERE OCCURS (SEE SHEAR SCHED FOR NAIL PATTERN) B.N. B.N. ROOF SHT'G 2x_ R.R. @ 16"oc (SEE FRAMING PLAN) ROOF PITCH PER PLAN SHT'G WHERE OCCURS (SEE SHEAR SCHED FOR NAILING PATTERN) 2x_ @ 16"o.c. SEE PLAN STUD WALL (BALLOON FRAMED) B.N. B.N. ROOF SHEATHING 2x_ R.R. @ 16" o.c. (SEE FRAMING) A-35 @ 16"o.c. 2x BLK'G @ 48"oc FASCIA TO MATCH EXST'G (N) 2x_ @ 16"oc STUD WALL NON-BEARING (E) C.J. OR F.J.CONT. BLK'G (N) LTP4 @ 32"oc2-2x4 TOP PL. (N) 2x_ @ 16"oc STUD WALL NON-BEARING (E) C.J. OR F.J. 2x BLK'G @ 48"oc 2-2x4 TOP PL. A35 @ EA. BLK. WALL PERP. JOIST WALL PARALLEL. JOIST 12" 2" 2" TOP PL. AWAY (N) R.R. 2x6 @ 16"oc (N) R.R. 2x6 @ 16"oc 4X6 4X6 4X6 4X 6 (E ) H D R 4X6 (E ) H D R (E) HDR (E) HDR L=9' 4x4 POST W/ MST60 4x4 POST W/ MST60 L= 1 2 ' 11 4x 6 P O S T W/ H D U 4 4x 6 P O S T W/ H D U 4 2- 2x6 C.J. (E) R.R. 2x6 @ 16"oc (E) R.R. 2x6 @ 16"oc (N) C.J. 2x6 @ 16"oc (N) R.R. 2x10 @ 16"oc WSWH24x14 WSWH24x14 WS W H 2 4 x 1 4 Y 10Y10Y10 X 10 X 10 X 10 Y 10Y10Y10 X 10 X 10 X 10 D 9 D 9 AA 1 BB DD EECC 2 4 3 4. 3 4x6 POST 4x6 POST 5 6 3X SILL PLATE 13 B1 W/ SDS SCREWS MICROLAM LVL TOP AND BOTTOM @6"o.c. STAGGERED B 11 C 11 RI D G E 2x 8 (5 ) 1 . 7 5 x 1 4 P S L 2 . 0 E 4x4 POST 2 - 4x6 POST E 11 2 - 4x6 KING POST BELOW TOP PL A35 AT EA. SIDE OF BEAM D 11 D 11 E 11 I 11 J 11 6 16 6 16 DATE SCALE DRAWN SHEET REVISIONS BY SHEET TITLE 11 UPPER ROOF 2066 LUIS L. AS NOTED 02.24.2023 30 6 S A I N T A N D R E W S R D NE W P O R T B E A C H , C A 9 2 6 6 3 AP N : 0 4 9 - 2 3 0 - 1 1 TR A C T : 1 2 2 0 LO T : 4 4 DATE SCALE DRAWN JOB SHEET REVISIONS BY SHEET TITLE of sheets JO B A D D R E S S LE G A L D E S C R I P T I O N a 02.24.2023 L.L. b -- DRAWINGS PREPARED BY LUIS LOPEZ 03.02.2023 (714) 417-7771 OCBuildersGroup.com PL A N C H E C K N O . c -- 23UPPER ROOF (LEVEL 2 WALLS) - FRAMING PLAN SCALE 1/4" = 1'-0" 5/8" AB @ 48" O.C.16d @ 6" O.C. 5/8" AB @ 32" O.C. 5/8" AB @ 24" O.C. 5/8" AB @ 16" O.C. 5/8" AB @ 16" O.C. 5/8" AB @ 8" O.C. 16d @ 5" O.C. 5/16" Lag @ 8" O.C. 5/16" Lag @ 6" O.C. 5/16" Lag @ 4" O.C. 5/16" Lag @ 8" O.C. 15/32" STR I PLYWD BLKD W/8d @ 6" O.C. E.N. & 12" O.C. F.N. 15/32" STR I PLYWD BLKD W/10d @ 4" O.C. E.N. & 12" O.C. F.N. 15/32" STR I PLYWD BLKD W/10d @ 3" O.C. E.N. & 12" O.C. F.N. 15/32" STR I PLYWD BLKD W/10d @ 2" O.C. E.N. & 12" O.C. F.N. 15/32" STR I PLYWD BLKD w/10d @ 6"O.C. E.N. & 12"O.C. F.N. 15/32" STR I PLYWD BLKD W/8d @ 4" O.C. E.N. & 12" O.C. F.N. TOP SIMPSON A35/LTP4 16" O.C. CONCRETE & MASONRY WALL SHEATHING (2)SYM SHEAR 10 280 WOOD SILL CONNECTION SHEAR WALL SCHEDULE 16" O.C. 12" O.C. 8" O.C. 8" O.C. 12" O.C. 11 12 1 1 340 430 13 1 15 1 14 665 870 510 CALIFORNIA BUILDING CODE (2019)ANCHORAGE SHEAR-WALL NOTES: A.ALL EXTERIOR WALL TO BE SECURED WITH 5/8" DIAM. X 16"A.b.'S AT 72" O.C. WITH 7" EMBED., UNLESS OTHERWISE NOTED, AND WITH MINIMUM 3"x3"x1/4" THICK PLATE WASHER UNDER NUT AT EACH BOLT. B.ALL INTERIOR WALLS WITH SHOT PINS; RAMSET # 3348, OR EQUIVALENT, AT 36" O.C. AT BEARING WALLS AND 48" O.C. AT NON-BEARING WALLS, UNLESS OTHERWISE NOTED. C.CODE MINIMUM (2) ANCHOR BOLTS PER PANEL. D.CODE MINIMUM 16d SOLE PLATE NAILS AT 16" O.C. TYPICAL AT ALL WOOD FRAMED FLOOR WALLS (U.O.N.). E.WHERE DOUBLE 2x SOLE PLATES ARE USED, PROVIDE PROGRESSIVE NAILING. F.ALL NAILS ARE COMMON NAILS. G.TABLE FOR USE WITH STUDS AT 16" O.C. MAXIMUM. H.ALL LAG BOLTS (LB) TO BE 6" LONG INSTALLED WITH PILOT HOLE AND WRENCH. J.5/8" DIAM. A.B. MAY BE REPLACED BY 5/8" DIAM. THREADED RODS BY 5" EMBED. WITH SIMPSON ET EPOXY, ICBO ER 4945, (OR EQUIVALENT) AT THE SAME SPACING, WITH SPECIAL INSPECTION. EACH BOLT SHALL HAVE MIN. 3"x3"x1/4" THICK SQUARE WASHER. K.FRAMING MEMBERS OR BLOCKING SHALL BE PROVIDED AT ALL EDGES OF ALL PLYWOOD SHEETS IN SHEAR WALL. SHEAR-WALL KEY NOTES: 1.USE 3x STUDS, AND 3x BOTTOM PLATE WITH STAGGERED NAILING WHERE THE ALLOWABLE SHEAR VALUE EXCEEDS 350 PLF. 2.WHERE SHEAR MATERIAL IS INSTALLED ON BOTH SIDES, THE SPACING FOR THE ABOVE TOP ANCHORAGE AND SILL CONNECTION SHALL BE HALF SHOWN. UNLESS OTHERWISE NOTED ON PLANS. ROOF PLYWOOD DIAPHRAGM (ROOF SHEATHING) USE 1/2" STRUCTURAL C-D OR C-C PLYWOOD, MIN. PANEL INDEX NUMBER (24/16),W/ 8d NAILS AT 6" O.C. SUPPORTED EDGES AND BOUNDARIES; AT 12" O.C. IN THE FIELD (UNBLOCKED U.N.O.). FACE GRAIN OF PLYWOOD SHALL BE PERPENDICULAR TO SUPPORTS. FLOOR DECK PLYWOOD DIAPHRAGM (FLOOR SHEATHING) USE 5/8" STRUCTURAL, C-D, OR C-C PLYWOOD, MIN. PANEL INDEX NUMBER (32/16) TONGUE & GROOVE, WITH 10d NAILS AT 6" O.C. SUPPORTED EDGES AND BOUNDARIES; AT 10" O.C. IN THE FIELD (UNBLOCKED U.N.O.) FACE GRAIN OF PLYWOOD SHALL BE PERPENDICULAR TO SUPPORTS. WALL TO ROOF SCALE 3/4" = 1'-0"B WALL TO ROOF SCALE 3/4" = 1'-0"DSCALE 3/4" = 1'-0"E RIDGE SCALE 3/4" = 1'-0"C WALL TO ROOF WALL TO ROOF SCALE 3/4" = 1'-0"D SCALE 3/4" = 1'-0"FDRAG STRAP WALL TO CEILING SCALE 3/4" = 1'-0"ISCALE 3/4" = 1'-0"JNOT USED SCALE 3/4" = 1'-0"K NOT USEDNOT USEDNOT USED FRAMING WALL TO ROOF SCALE 3/4" = 1'-0"A POST TO BEAM SCALE 3/4" = 1'-0"E WALL TO CEILING DATE SCALE DRAWN SHEET REVISIONS BY SHEET TITLE 14 STRUCTURAL 2066 LUIS L. AS NOTED 02.24.2023 30 6 S A I N T A N D R E W S R D NE W P O R T B E A C H , C A 9 2 6 6 3 AP N : 0 4 9 - 2 3 0 - 1 1 TR A C T : 1 2 2 0 LO T : 4 4 DATE SCALE DRAWN JOB SHEET REVISIONS BY SHEET TITLE of sheets JO B A D D R E S S LE G A L D E S C R I P T I O N a 02.24.2023 L.L. b -- DRAWINGS PREPARED BY LUIS LOPEZ 03.02.2023 (714) 417-7771 OCBuildersGroup.com PL A N C H E C K N O . c -- 23 FRAMING NOTES 1.FRAMING REQUIREMENTS SUCH AS NAILING, LET-IN DIAGONAL BRACES, ETC., SHALL BE IN ACCORDANCE WITH MINIMUM REQUIREMENTS OF THE APPLICALBE CODES UNLESS GREATER REQUIREMENTS ARE INDICATED ON PLANS OR SPECIFICATIONS. 2.FRAMING LUMBER SHAL COMPLY WITH DOC PS20. SHALL BE DOUGLAS FIR / LARCH, EXCEPT WHERE NOTED. 2X FLOOR JOIST NO.2 4X BEAMS NO.2 6X BEAMS OR GREATER AS NOTED 2X4 OR 4X4 STUDS OR POSTS STD. OR STUD GRADE 2X6 STUDS OR GREATER NO.2 6X POSTS OR GREATER NO. 1 3.WOOD STRUCTURAL PANELS SHALL COMPLY WITH DOC PS1 OR DOC PS2 4.ALL GLUED LAMINATED LUMBER SHALL CONFORM TO CITY, COUNTY AND STATE CODES AND CURRENT A.I.T.C. STANDARDS. A CERTIFICATIONS OF FABRICATION SHALL BE SUBMITTED TO LOCAL BUILDING DEPARTMENT FOR APPROVAL. 5.PLYWOOD USED AS FLOOR OR ROOF SHEATHING OR AT SHEAR WALLS SHALL CONFRORM TO DOC PS-1 AND SHALL BE STAMP-GRADED BY THE AMERICAN PLYWOOD ASSOCIATION. PLYWOOD SHALL BE INTERIOR TYPE WITH EXTERIOR GLUE. USE EXTERIOR GRADE WHERE EXPOSED TO THE WEATHER. 6.ROOF SHEATHING 1/2 IN. STD. INT-APA PLYWOOD WITH EXTERIOR GLUE INDEX 24/0. PS 1 LAY PANELS WITH FACE GRAIN ACROSS SUPPORTS.STAGGER PANEL END JOINTS. 7.FLOOR SHEATHING 5/8 IN. T&G INT-APA PLYWOOD WITH EXTERIOR GLUE INDEX #32/16, PS 1: NAIL WITH 10D @ 6 IN. O.C. ALONG PANEL EDGES AND 12 IN. O.C. AT INTERMEDIATE SUPPORTS. LAY PANELS WITH FACE GRAIN ACROSS SUPPORTS. STAGGER PANEL END JOINTS, EXCEPT WHERE NOTED. 8.FLOOR JOIST DOUBLE FLOOR JOIST UNDER ALL PARALLEL PARTITIONS. 2X SOLID BLOCKING AT 8'-0" O.C. AND AT SUPPORTS. 9.FASTENING OF BUILT - UP BEAMS. 2-2X 16D @ 12" STAGGERED 3-2X OR UP TO 5-2X 1/2" M.B. @24" O.C. STAG FASTENINGS SHALL BE PLACED AT A MAXIMUM OF 1/4 THE BEAM DEPTH FROM TOP OF BOTTOM EDGE. 10.RAFTER BLOCKING AND BRIDGING 2X8 RAFTERS OR SMALLER BLKG REQ'D AT SUPPORTS ONLY. 2X10 RAFTERS OR LARGER BLKG REQ'D AT SUPPORTS AND EVERY 10' BET. SUPPORTS PROVIDE 2X4; RAFTER TIES @ 4'0" O.C. WHERE JOIST AND RAFTERS NOT PARALLEL. 11.EXTERIOR AND BEARING STUD WALL REQUIREMENTS MAX. HEIGHT: UP TO 14' HEIGHT 2X4 @ 16 UP TO 20' HEIGHT 2X6 @ 16 UP TO 22' HEIGHT 2X8 @ 16 UP TO 24' HEIGHT 2X10 @ 16 OR 2X8 @ 8 12.ALL WALL STUDS SHALL BE 2X4 @ 16" O.C. UNLESS OTHERWISE NOTED. 13.ALL STUD WALLS OVER 10' IN HEIGHT SHALL BE SOLID BLOCKED AT MID-HEIGHT OR AS NECESSARY SO THAT NO CONCEALED SPACE IS OVER 10' IN LENGTH. 14.PROVIDE 1X6 DIAGONAL BRACING AT CORNERS AND EVERY 25' OF WALL AND ALL CRIPPLE WALL OVER 4'0" HIGH. 15.WHERE PLUMBING HEATING OR OTHER PIPES ARE PLACED IN OR PARTLY IN A PARTITION, NECESSITATING THE CUTTING OF THE PLATES OR WHEN PLATES DO NOT HAVE APPROVED LAPPING, A METAL TIE STRAP OF NOT LESS THAN 1/8" AND 1-1/2" WIDTH SHALL BE FASTENED TO THE PLATE ACROSS AND TO EACH SIDE OF THE OPENING WITH NOT LESS THAN 4 16D NAILS ON EACH SIDE. 16.SILLS AND PLATES SILLS AND PLATES AT SHEAR WALLS SHALL BE CONTINUOUS AND FREE OF CUTS AND NOTCHES. PERFORATIONS SHALL BE ALLOWED WITH AMAXIMUM OF 1-3/4" DIAMETER AND SHALL BE LOCATED AS CLOSE TO CENTER AS POSSIBLE. SILL BOLTS TO ENTER CONCRETE 7" MINIMUM AND 12" MAXIMUM FROM ENDS OF SILL AND CORNERS, EXCEPT WHERE NOTED. 17.SHEAR WALLS TO BE STRUCTURAL #1 PLYWOOD WITH NAILING AS NOTED. ALL NAILS TO PENETRATE FRAMING MEMBER. ALL HOLD DOWNS TO HAVE MINIMUM 1/2" CLEARANCE FROM SILL OR PLATE. BOLTS TO FIT SNUGLEY NOT SLOTTED. PURLIN ANCHORS WHERE USED SHALL BE BOLTED UNLESS NOTED. PROVIDE 2-LAYERS OF GRADE 'D' PAPER OVER PLYWOOD UNDER STUCCO AT THE SHEARWALLS. FOUDATION NOTES 1.DESIGN SOIL BEARING PRESSURE 1000 P.S.F. 2.CONCRETE: F'c CEMENT TYPE & WATER-CEMENT RATIO. MINIMUM ULTIMATE COMPRESSIVE STRENGTH @ 28 DAYS: 2500 PSI. CONTINUOUS INSPECTION NOT REQUIRED. CEMENT SHALL CONFORM TO ASTM-C-150. FINE AND COURSE AGGREGATE SHALL CONFORM TO ASTM C-33 CONCRETE MIX: 1:2 1/2:3 1/2 WITH MAXIMUM WATER CONTENT OF 7 1/2 GALLONS PER SACK OF CEMENT. 3.CONCRETE IN CONTACT WITH THE SOIL SHALL HAVE AN ULTIMATE COMPRESSIVE STRENGTH OF 2500 PSI WAETER -CEMENT RATIO OF 0.45 AND TYPE V CEMENT UNLESS A SOIL REPORT RECOMMENDS OTHERWISE 4.FOUDATION SHALL BE CARRIED INTO NATURAL GRADE NOT LESS THAN INDICATED ON DETAILS. 5.WHERE SOIL IS EXPANSIVE, VERIFY FOOTING REQUIREMENTS WITH LOCAL BUILDING AND SAFETY DEPARTMENT. 6.REINFORCEMENT: REINFORCEMENT STEEL SHALL CONFORM TO ASTM A615-40, INTERMIEDIATE GRADE. ALL BARS EXEPT #2 SHALL BE DEFORMED. DEFORMATION CONFORMING TO ASTM A305.MINIMUM CLEAR DISTANCE OF REINFORCING FROM FACE OF CONCRETE:POURED AGAINST EARTH: 3" WALL OR COLUMN POURED AGAINST FROM: 2" 7.ALL WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185/LAP 6" 8.TOP OF FOUNDATION SHALL BE 6" MIN. ABOVE FINISHED GRADE. 9.MUD SILLS TO BE 2" X PRESSURE TREATED D.E. BOLTED WITH 5/8" DIAG. X 10" BOLTED 7 IN. MIN. INTO CONCRETE 3" X 3" X 0.229" OD 1/4" PLT. WASHERS. 10.PROVIDE METAL WASHERS UNDER ALL BOLT HEADS AND NUTS BEARING ON WOOD. ALL BOLTS THROUGH WOOD TO BE DRIVE FIT. 11.PROVIDE WEEP SCREED AROUND PERIMETER OF ALL CONCRETE SLABS. 12.WATERPROOF ALL RETAINING WALLS ADJACENT TO LIVABLE AREAS AND GARAGE. 13.ALL GALVANIZED IRON FLASHING SHALL BE NO LESS THAN 26 GA. 14.ALL FOOTINGS SHALL BE 24" MIN. EMBEDED INTO ADJACENT LOWER GRADE AND SLAB ON GRADE SHALL BE 5" THICK CONC. SLAB W/ #4 @ 12"oc AT MID LAYER OF 2" SAND AND OVER 15 MIL VISQUEEN AND OVER 4" THICK OF 1/2" DIA. CLEAN GRAVEL AND OVER COMPACT SOIL. MASONRY 1.USE TYPE M MORTAR 1 PART PORTLAND CEMENT, 1/4 PART LIME PUTTY, 3 PARTS DAMP LOOSE SAND. 2.USE TYPE N.I. HOLLOW CONCRETE UNITS - SOLID GROUTED. 3.USE 2000 P.S.I. MIN. @ 28 DAYS. 4.REINFORCING STEEL ASTM - A615 GRADE 40 NOTES FASTENING SCHEDULE ITEM DESCRIPTION OF BUILDING ELEMENTS NUMBER AND TYPE OF FASTENERa, b, c Roof 1 2 Blocking between ceiling joists or rafters to top plate Ceiling joists to top plate 3 Ceiling joist not attached to parallel rafter, laps over partitions [see Sections R802.3.1, R802.3.2 and Table R802.5.1(9)] 4 5 6 Ceiling joist attached to parallel rafter (heel joint) [see Sections R802.3.1 and R802.3.2 and Table R802.5.1(9)] Collar tie to rafter, face nail or 11/4" × 20 ga. ridge strap to rafter Rafter or roof truss to plate 4-8d box (21/2" × 0.113") or 3-8d common (21/2" × 0.131"); or 3-10d box (3" × 0.128"); or 3-3" × 0.131" nails 4-8d box (21/2" × 0.113"); or 3-8d common 21/2" × 0.131"); or 3-10d box (3" × 0.128"); or 3-3" × 0.131" nails 4-10d box (3" × 0.128"); or 3-16d common (31/2" × 0.162"); or 4-3" × 0.131" nails Table R802.5.1(9) 4-10d box (3" × 0.128"); or 3-10d common (3" × 0.148"); or 4-3" × 0.131" nails 3-16d box nails (31/2" × 0.135"); or 3-10d common nails (3" × 0.148"); or 4- 10d box (3" × 0.128"); or 4-3" × 0.131" nails 7 Roof rafters to ridge, valley or hip rafters or roof rafter to minimum 2" ridge beam 4-16d (31/2" × 0.135"); or 3-10d common (31/2" × 0.148"); or 4-10d box (3" × 0.128"); or 4-3" × 0.131" nails 3-16d box (31/2" × 0.135"); or 2-16d common (31/2" × 0.162"); or 3-10d box (3" × 0.128"); or 3-3" × 0.131" nails Wall 16d common (31/2" × 0.162") 8 Stud to stud (not at braced wall panels) 10d box (3" × 0.128"); or 3" × 0.131" nails 9 Stud to stud and abutting studs at intersecting wall corners (at braced wall panels) 16d box (31/2" × 0.135"); or 3" × 0.131" nails 16d common (31/2" × 0.162") 16d common (31/2" × 0.162") 10 Built-up header (2" to 2" header with 1/2" spacer) 16d box (31/2" × 0.135") 11 Continuous header to stud 5-8d box (21/2" × 0.113"); or 4-8d common (21/2" × 0.131"); or 4-10d box (3" × 0.128") 16d common (31/2" × 0.162") 12 Top plate to top plate 10d box (3" × 0.128"); or 3" × 0.131" nails Double top plate splice for SDCs A-D2 with seismic braced wall line spacing < 25'13 Double top plate splice SDCs D0, D1, or D2; and braced wall line spacing ≥ 25' 14 Bottom plate to joist, rim joist, band joist or blocking (not at braced wall panels) 15 Bottom plate to joist, rim joist, band joist or blocking (at braced wall panel) 12-16d (31/2" × 0.135") 16d common (31/2" × 0.162") 16d box (31/2" × 0.135"); or 3" × 0.131" nails 3-16d box (31/2" × 0.135"); or 2-16d common (31/2" × 0.162"); or 4-3" × 0.131" nails 4-8d box (21/2" × 0.113"); or 3-16d box (31/2" × 0.135"); or 4-8d common (21/2" × 0.131"); or 4-10d box (3" × 0.128"); or 4-3" × 0.131" nails 16 Top or bottom plate to stud 16" o.c. face nail 12" o.c. face nail 3 each 16" o.c. face nail 2 each 16" o.c. face nail 4 each 16" o.c. face nail Toe nail 8-16d common (31/2" × 0.162"); or 12-16d box (31/2" × 0.135"); or 12-10d box (3" × 0.128"); or 12-3" × 0.131" nails 12" o.c. face nail 12" o.c. each edge face nail Toe nail 16" o.c. face nail 16" o.c. face nail 12" o.c. face nail 16" o.c. face nail 16" o.c. each edge face nail 24" o.c. face nail Toe nail Per joist, toe nail SPACING AND LOCATION Face nail Face nail Face nail each rafter 2 toe nails on one side and 1 toe nail on opposite side of each rafter or trussi Toe nail End nail Face nail on each side of end joint (minimum 24" lap splice length each side of end joint) 3-16d box (31/2" × 0.135"); or 2-16d common (31/2" × 0.162"); or 3-10d box (3" × 0.128"); or 3-3" × 0.131" nails End nail 17 Top plates, laps at corners and intersections 18 1" brace to each stud and plate 19 1" × 6" sheathing to each bearing 3-10d box (3" × 0.128"); or 2-16d common (31/2" × 0.162"); or 3-3" × 0.131" nails 3-8d box (21/2" × 0.113"); or 2-8d common (21/2" × 0.131"); or 2-10d box (3" × 0.128"); or 2 staples 13/4" 3-8d box (21/2" × 0.113"); or 2-8d common (21/2" × 0.131"); or 2-10d box (3" × 0.128"); or 2 staples, 1" crown, 16 ga., 13/4" long 3-8d box (21/2" × 0.113"); or 3-8d common (21/2" × 0.131"); or 3-10d box (3" × 0.128"); or 3 staples, 1" crown, 16 ga., 13/4" long 20 1" × 8" and wider sheathing to each bearing Wider than 1" × 8" 4-8d box (21/2" × 0.113"); or 3-8d common (21/2" × 0.131"); or 3-10d box (3" × 0.128"); or 4 staples, 1" crown, 16 ga., 13/4" long 21 Joist to sill, top plate or girder 22 Rim joist, band joist or blocking to sill or top plate (roof applications also) 23 24 25 26 1" × 6" subfloor or less to each joist 2" subfloor to joist or girder 2" planks (plank & beam—floor & roof) Band or rim joist to joist 4-8d box (21/2" × 0.113"); or 3-8d common (21/2" × 0.131"); or 3-10d box (3" × 0.128"); or 3-3" × 0.131" nails 8d box (21/2" × 0.113") 8d common (21/2" × 0.131"); or 10d box (3" × 0.128"); or 3" × 0.131" nails 3-8d box (21/2" × 0.113"); or 2-8d common (21/2" × 0.131"); or 3-10d box (3" × 0.128"); or 2 staples, 1" crown, 16 ga., 13/4" long 3-16d box (31/2" × 0.135"); or 2-16d common (31/2" × 0.162") 3-16d box (31/2" × 0.135"); or 2-16d common (31/2" × 0.162") 3-16d common (31/2" × 0.162") 4-10 box (3" × 0.128"), or 4-3" × 0.131" nails; or 4-3" × 14 ga. staples, 7/16" crown 20d common (4" × 0.192"); or 27 Built-up girders and beams, 2-inch lumber layers 10d box (3" × 0.128"); or 3" × 0.131" nails And: 2-20d common (4" × 0.192"); or 3-10d box (3" × 0.128"); or 3-3" × 0.131" nails 28 29 Ledger strip supporting joists or rafters Bridging to joist 4-16d box (31/2" × 0.135"); or 3-16d common (31/2" × 0.162"); or 4-10d box (3" × 0.128"); or 4-3" × 0.131" nails 2-10d (3" × 0.128") Toe nail 4" o.c. toe nail 6" o.c. toe nail Face nail Blind and face nail At each bearing, face nail End nail Nail each layer as follows: 32" o.c. at top and bottom and staggered. 24" o.c. face nail at top and bottom staggered on opposite sides Face nail at ends and at each splice At each joist or rafter, face nail Each end, toe nail SPACING OF FASTENERS ITEM DESCRIPTION OF BUILDING ELEMENTS NUMBER AND TYPE OF FASTENERa, b, c Edges (inches)h Intermediate supportsc, e (inches) Wood structural panels, subfloor, roof and interior wall sheathing to framing and particleboard wall sheathing to framing [see Table R602.3(3) for wood structural panel exterior wall sheathing to wall framing] 30 31 32 3/8" — 1/2" 19/32" — 1" 11/8" — 11/4" 6d common (2" × 0.113") nail (subfloor, wall)i 8d common (21/2" × 0.131") nail (roof) 8d common nail (21/2" × 0.131") 10d common (3" × 0.148") nail; or 8d (21/2" × 0.131") deformed nail Other wall sheathingg 33 1/2" structural cellulosic fiberboard sheathing 34 25/32" structural cellulosic fiberboard sheathing 35 36 1/2" gypsum sheathingd 5/8" gypsum sheathingd 11/2" galvanized roofing nail, 7/16" head diameter, or 1" crown staple 16 ga., 11/4" long 13/4" galvanized roofing nail, 7/16" head diameter, or 1" crown staple 16 ga., 11/4" long 11/2" galvanized roofing nail; staple galvanized, 11/2" long; 11/4" screws, Type W or S 13/4" galvanized roofing nail; staple galvanized, 15/8" long; 15/8" screws, Type W or S Wood structural panels, combination subfloor underlayment to framing 37 38 3/4" and less 7/8" — 1" 6d deformed (2" × 0.120") nail; or 8d common (21/2" × 0.131") nail 8d common (21/2" × 0.131") nail; or 8d deformed (21/2" × 0.120") nail 6 6 12 12 3 6 6 6 6 12f 12f 12 Face nail Face nail Face nail Face nail 3 6 7 7 7 7 39 11/8" — 11/4"10d common (3" × 0.148") nail; or 8d deformed (21/2" × 0.120") nail For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 mile per hour = 0.447 m/s; 1 ksi = 6.895 MPa. a. Nails are smooth-common, box or deformed shanks except where otherwise stated. Nails used for framing and sheathing connections shall have minimum average bending yield strengths as shown: 80 ksi for shank diameter of 0.192 inch (20d common nail), 90 ksi for shank diameters larger than 0.142 inch but not larger than 0.177 inch, and 100 ksi for shank diameters of 0.142 inch or less. b. Staples are 16 gage wire and have a minimum 7/16-inch on diameter crown width. c. Nails shall be spaced at not more than 6 inches on center at all supports where spans are 48 inches or greater. d. Four-foot by 8-foot or 4-foot by 9-foot panels shall be applied vertically. e. Spacing of fasteners not included in this table shall be based on Table R602.3(2). f. Where the ultimate design wind speed is 130 mph or less, nails for attaching wood structural panel roof sheathing to gable end wall framing shall be spaced 6 inches on center. Where the ultimate design wind speed is greater than 130 mph, nails for attaching panel roof sheathing to intermediate supports shall be spaced 6 inches on center for minimum 48-inch distance from ridges, eaves and gable end walls; and 4 inches on center to gable end wall framing. g. Gypsum sheathing shall conform to ASTM C1396 and shall be installed in accordance with GA 253. Fiberboard sheathing shall conform to ASTM C208. h. Spacing of fasteners on floor sheathing panel edges applies to panel edges supported by framing members and required blocking and at floor perimeters only. Spacing of fasteners on roof sheathing panel edges applies to panel edges supported by framing members and required blocking. Blocking of roof or floor sheathing panel edges perpendicular to the framing members need not be provided except as required by other provisions of this code. Floor perimeter shall be supported by framing members or solid blocking. i. Where a rafter is fastened to an adjacent parallel ceiling joist in accordance with this schedule, provide two toe nails on one side of the rafter and toe nails from the ceiling joist to top plate in accordance with this schedule. The toe nail on the opposite side of the rafter shall not be required. 6 12 WSW PANEL MODEL MODEL NO.DIAMETER LENGTH le 1 2 3 4 6 5 STRONG-WALL® WSW ANCHORAGE - TYPICAL SECTIONS WSW ANCHOR BOLTS WSW ANCHOR BOLT EXTENSION WSW ANCHOR BOLT TEMPLATES STRONG-WALL® WOOD SHEARWALL TENSION ANCHORAGE SCHEDULE 2,500, 3,000 AND 4,500 PSI STRONG-WALL® WSW SHEAR ANCHORAGE SCHEDULE AND DETAILS BRICK LEDGE FOUNDATIONSLAB ON GRADE FOUNDATION INTERIOR FOUNDATION CURB OR STEMWALL FOUNDATION WSW ANCHORAGE SOLUTIONS FOR 2500 PSI CONCRETE DESIGN CRITERIA CONCRETE CONDITION ANCHOR STRENGTH WSW-AB78 ANCHOR BOLT WSW-AB1 ANCHOR BOLT ASD ALLOWABLE UPLIFT (lbs) W (in) de (in) ASD ALLOWABLE UPLIFT (lbs) W (in) de (in) FOUNDATION PLAN VIEW ® WSW ANCHORAGE SOLUTIONS FOR 3000 PSI CONCRETE DESIGN CRITERIA CONCRETE CONDITION ANCHOR STRENGTH WSW-AB78 ANCHOR BOLT WSW-AB1 ANCHOR BOLT ASD ALLOWABLE UPLIFT (lbs) W (in) de (in) ASD ALLOWABLE UPLIFT (lbs) W (in) de (in) WSW ANCHORAGE SOLUTIONS FOR 4500 PSI CONCRETE DESIGN CRITERIA CONCRETE CONDITION ANCHOR STRENGTH WSW-AB78 ANCHOR BOLT WSW-AB1 ANCHOR BOLT ASD ALLOWABLE UPLIFT (lbs) W (in) de (in) ASD ALLOWABLE UPLIFT (lbs) W (in) de (in) 36 HS 1 WSW PANEL MODEL MODEL NO.DIAMETER LENGTH le 24 HX WSW-HSR AND WSW-AB ASSEMBLY 1 WSW-HSR_KT HAIRPIN INSTALLATION SECTION A HAIRPIN SHEAR REINFORCEMENT TIE SHEAR REINFORCEMENT (GARAGE CURB SHOWN. OTHER FOOTING TYPES SIMILAR.) - A STRONG-WALL® WOOD SHEARWALL SHEAR ANCHORAGE MODEL SEISMIC3 WIND4 Lt OR Lh (in.) SHEAR REINFORCEMENT MIN. CURB/ STEMWALL WIDTH (in.) SHEAR REINFORCEMENT MIN. CURB/ STEMWALL WIDTH (in.) ASD ALLOWABLE SHEAR LOAD V (lbs.)6 6" MIN CURB/STEMWALL UNCRACKED CRACKED WSW-RT EXTERIOR INSTALLATION WSW-RT INTERIOR INSTALLATION WSW-RTPF PANEL FORM INSTALLATION WSW-RTBL BRICK LEDGE INSTALLATION ST R O N G - W A L L W S W AN C H O R A G E D E T A I L S EN G I N E E R E D D E S I G N S ® WSW1 N.T.S. 06-18-2020 0 07 - 0 1 - 2 0 1 6 FI R S T R E L E A S E - 2 0 1 5 I B C 1 06 - 1 8 - 2 0 2 0 20 1 8 I B C R E V I S I O N S SI M P S O N S t r o n g - T i e , C o . I n c . TH E R E I S N O E Q U A L TH E R E I S N O E Q U A L 15 23 ® MODEL NO.W (in.)H (in.)ANCHOR BOLTS TOTAL WALL WEIGHT (lb.)QUANTITY DIA. (in.) ® · · ® ® ® GARAGE HEADER ROUGH OPENING HEIGHT MODEL NO.H CURB ROUGH OPENING HEIGHT ® GARAGE WALL OPTION 1 GARAGE WALL OPTION 2 SECTION 4x FRAMING ® WSW-TOW ALTERNATE CONNECTION KIT MODEL NO.FASTENER QUANTITY SD #10x112"SDS 14"x6" SECTION VIEW 2X6 OR WIDER FRAMING EDGE DISTANCE FOR SCREWS ® ® ® PLAN VIEW SDS SCREW SPACING QTY. OF SDS14"x6" SCREWS REQ'D. SECTION ® · · · · 1" TO 4" SHIM BLOCK418" TO 12" SHIM BLOCK ® CRIPPLE WALL ® SECTION 6x FRAMING ALLOWABLE SMALL HOLES FACE AND EDGE DRILL ZONES ALLOWABLE LARGE HOLES IN ADDITION TO ALLOWABLE SMALL HOLES ® ® ® · · ® ® SECTION 4x FRAMING SECTION 6x FRAMING · · · STRONG-WALL® WOOD SHEARWALL MODELS 1STRONG-WALL® WSW MODELS 6 9 TRIM ZONE AND ALLOWABLE HOLES 5WOOD FLOOR SYSTEM BASE CONNECTION 7ALTERNATE TOP CONNECTION 11 ® ● ● ● 6 - 7 - 4 - 5 - 6 - 7 - 6 - 7 - 4 - 4 - 3 ® ® INTERIOR ELEVATION EXTERIOR ELEVATION SECTION WALL WIDTH (in.)MODEL NO.CONTENTS ALTERNATE WSW GARAGE FRONT OPTIONS SINGLE STORY WSW ON CONCRETE 2 8 4 10 ALTERNATE WSW GARAGE FRONT OPTIONS STANDARD INSTALLATION STANDARD TOP CONNECTION TOP OF WALL HEIGHT ADJUSTMENTS FIRST FLOOR AT WOOD FRAMING ST R O N G - W A L L W S W FR A M I N G D E T A I L S EN G I N E E R E D D E S I G N S ® WSW2 N.T.S. 07-17-2020 0 07 - 0 1 - 2 0 1 6 FI R S T R E L E A S E - 2 0 1 5 I B C 1 07 - 1 7 - 2 0 2 0 20 1 8 I B C R E V I S I O N S SI M P S O N S t r o n g - T i e , C o . I n c . TH E R E I S N O E Q U A L TH E R E I S N O E Q U A L 16 23 CHAIN LINK POOL BARRIERVERTICAL AND HORIZONTAL MEMBER - POOL BARRIERVERTICAL AND HORIZONTAL MEMBER - POOL BARRIER 2" M A X CL E A R A N C E SELF CLOSING HINGES SELF-LATCHING DEVICE 54" ABOVE GRADE 45 " O R M O R E 60 " M I N I M U M H E I G H T LESS THAN 4" 2" M A X CL E A R A N C E 60 " M I N I M U M H E I G H T 60 " M I N I M U M H E I G H T 1-3/4" MAXIMUM HORIZONTAL MEMBERS REQUIRED TO BE ON POOL SIDE OF FENCE / GATE SELF-LATCHING DEVICE REQUIRED TO BE 54" ABOVE GRADE 54 " M I N 54 " M I N 54 " M I N GATE REQUIRED TO OPEN OR SWING AWAY FROM POOL GATE REQUIRED TO OPEN OR SWING AWAY FROM POOL GATE REQUIRED TO OPEN OR SWING AWAY FROM POOL SELF CLOSING HINGES SELF CLOSING HINGES SELF-LATCHING DEVICE REQUIRED TO BE 54" ABOVE GRADE 2" M A X CL E A R A N C E MAX. MESH SIZE 1-3/4" UNLESS THE FENCE IS PROVIDED WITH SLATS THAT REDUCE OPENINGS TO NO MORE THAN 1-3/4" POOL SAFETY REQUIREMENT - Enclosures/Barriers Drowning is the leading cause of accidental death for children under five (5) years of age in California. Over 4,600 drowning and near drowning incidents occur nationwide each year in private swimming pools. The use of effective residential swimming pool barriers in conjunction with adult supervision is the best way to minimize these accidents. An outdoor swimming pool, including an in-ground, above-ground and on-ground pool, hot tub or spa shall be provided with a barrier which shall comply with the following: a. The top of the barrier shall be at least sixty (60) inches above grade measured on the side of the barrier which faces away from the swimming pool. b. The maximum vertical clearance between grade and the bottom of the barrier shall be two (2) inches measured on the side of the barrier which faces away from the swimming pool. Where the top of the pool structure is above grade, the barrier may be at the ground level, such as the pool structure, or mounted on top of the pool structure. Where the barrier is mounted on top of the pool structure, the maximum vertical clearance between the top of the pool structure and the bottom of the barrier shall be four (4) inches. c. Openings in the barrier shall not allow passage of a four-inch diameter (4”) sphere. d. Solid barriers which do not have openings, such as masonry or stone walls, shall not contain indentations or protrusions except for tooled masonry joints. e. Where the barrier is composed of horizontal members (cross rails) and the horizontal spacing is less than forty five (45) inches, the horizontal members shall be located on the swimming pool side of the fence. Spacing between vertical members shall not exceed one and three fourths (1-3/4”) inches in width. Where there are decorative cutouts within vertical members, spacing within the cutouts shall not exceed one and three fourths (1-3/4”) in width. f. Where the barrier is composed of horizontal and vertical members and the distance between the tops of the horizontal members (cross rails) is forty five (45”) inches or more, spacing between vertical members shall not exceed four (4”) inches. Where there are decorative cutouts within vertical members, spacing within the cutouts shall not exceed three fourths (3/4”) inches in width. g. Maximum mesh size for chain link fences shall be a one and one quarter inch (1-1/4”) square unless the fence is provided with slats fastened at the top or the bottom, which reduce the openings to no more than one and three fourths (1- 3/4”) inches. The wire shall not be less than eleven (11) gage. h. Where the barrier is composed of diagonal members, openings shall be no more than one and three fourths (1-3/4”) inches. i. Access gates shall comply with the above requirements and shall be equipped to accommodate a locking device. Pedestrian-access gates shall open outward away from the pool and shall be self-closing and have a self-latching device. Gates other than pedestrian access gates shall have a self-latching device. Where the release mechanism of the self-latching device is located less than fifty four (54”) inches from the bottom of the gate, the release mechanism shall be located on the pool side of the gate at least three (3”) inches below the top of the gate and the gate and barrier shall have no opening greater than one half (1/2) inches within eighteen (18”) of the release mechanism. j. Where a wall of a dwelling serves as a part of the barrier, doors with direct access to the pool through that wall shall be equipped with an alarm which produces an audible warning when the door and its screen, if present, are opened. The alarm shall sound continuously for a minimum of thirty (30) seconds immediately after the door is opened, and be capable of being heard throughout the house during normal household activities. The alarm shall automatically reset under all conditions. The alarm system shall be equipped with a manual means, such as a touchpad or switch, to temporarily deactivate the alarm for a single opening. Such deactivation shall last for no more than 15 seconds. The deactivation switch shall be located at least fifty four (54) inches above the threshold of the door. k. Where an above ground pool structure is used as a barrier or where the barrier is mounted on top of the pool structure and the means of access is a ladder or steps, then the means of access or the ladder or steps shall be surrounded by a barrier which meets the above requirements. When the ladder or steps are secured, locked or removed, any opening created shall not allow the passive of a four (4”) inch diameter sphere. l. Doors with direct access to an indoor swimming pool shall comply with (j.) above. m. The pool shall be equipped with an approved safety pool cover that meets all the requirements of ASTM Specifications F1346. n. Refer to 2016 California Building Code section 3109 for complete requirements. NEW REGULATIONS AS OF 1/1/2018 (CA Health and Safety Code Sec 115922) When a building permit is issued for the construction of a new swimming pool or spa or the remodeling of an existing swimming pool or spa at a private single-family home, the respective swimming pool or spa shall be equipped with at least two of the following seven drowning prevention safety features: 1. A complying enclosure that isolates the swimming pool or spa from the private single-family home. This is separate and in addition to property enclosure fencing. See Enclosure/Barrier requirements under General Requirements of this handout for enclosure requirements. 2. Removable mesh fencing that meets the standards of ASTM F2286 in conjunction with a self-closing and self-latching gate that can accommodate a key lockable device. 3. An approved safety pool cover. either manually or power-operated that meets all of the performance standards of ASTM F1346-91. 4. Exit alarms on the private single-family home’s doors that provide direct access to the swimming pool or spa. The exit alarm may cause either an alarm noise or a verbal warning, such as a repeating notification that “the door to the pool is open.” 5. A self-closing, self-latching device with a release mechanism placed no lower than 54 inches above the floor on the private single-family home’s doors providing direct access to the swimming pool or spa. 6. An alarm that, when placed in a swimming pool or spa, will sound upon detection of accidental or unauthorized entrance into the water. The alarm shall meet and be independently certified to ASTM Standard F2208 “Standard Safety Specification for Residential Pool Alarms,” which includes surface motion, pressure, sonar, laser, and infrared type alarms. A swimming protection alarm feature designed for individual use, including an alarm attached to a child that sounds when the child exceeds a certain distance or becomes submerged in water, is not a qualifying drowning prevention safety feature. 7. Other means of protection, if the degree of protection afforded is equal to or greater than that afforded by any of the features set forth above and has been independently verified by an approved testing laboratory as meeting standards for those features established by ASTM or ASME. 8. Before the issuance of final approval for the completion of the permitted construction or remodeling work, inspection and approval of the drowning safety prevention features required by this section is mandatory. Note: These requirements do not apply to public swimming pools, hot tubs or spas with approved locking safety covers, pools in apartment complexes or any setting other than a single-family home. SWIMMING POOL DROWNING PREVENTION SAFETY FEATURES MEASURE Effective January 1, 2018, Health and Safety Code Section 115922 (Building Code Section 3109.4.4.2) requires new swimming pools or spas or remodeled swimming pools or spas at a private single-family home to be equipped with at least 2 drowning prevention safety features. Compliance with the pool enclosure requirements (see below OPTION 1 & OPTION 2) serves as one of the required safety features. A second feature from the list belowmust also be installed. PoolBACKYARD Fence all around pool Attachment B Self-closing/ Self-latching Gate House Garage OPTION - 1 Fence around pool, including building wall Pool BACKYARD Fence around property line Sliding Door Alarm Door Alarm or Self-Closing/Self-Latching Self-Closing/ Self-Latching House Self-closing/ Self-latching Gate OPTION - 2 DROWNING PREVENTION SAFETY FEATURES (SECOND FEATURE): AT LEAST ONE FEATURE MUST BE CHOSEN Removable mesh fencing that meets ASTM Standard F2286 – 60” high minimum A pool safety cover that meets ASTM Standard F1346 Other means of protection, if the degree of protection afforded is equivalent to the other devices specified above, and has been independently verified by an approved testing laboratory as meeting standards for the device established by ASTM or ASME. Note: Release mechanism for doors with direct access from home or accessory structures shall be placed no lower than 54” above the floor, and for gates through enclosure shall be placed no lower than 60” above the ground. A pool alarm that, when placed in the pool, will sound upon detection of entrance into the water. The pool alarm shall meet ASTM Standard F2208. Garage Self-closing/ Self-latching Gate POOL FENCE / ALARM OPTIONS DATE SCALE DRAWN JOB SHEET REVISIONS BY SHEET TITLE 17 NOTES 2066 LUIS L. AS NOTED 02.24.2023 30 6 S A I N T A N D R E W S R D NE W P O R T B E A C H , C A 9 2 6 6 3 AP N : 0 4 9 - 2 3 0 - 1 1 TR A C T : 1 2 2 0 LO T : 4 4 DATE SCALE DRAWN JOB SHEET REVISIONS BY SHEET TITLE of sheets JO B A D D R E S S LE G A L D E S C R I P T I O N a 02.24.2023 L.L. b -- DRAWINGS PREPARED BY LUIS LOPEZ 03.02.2023 (714) 417-7771 OCBuildersGroup.com PL A N C H E C K N O . c -- 23 JOB POOL SAFETY CHAIN LINK POOL BARRIERVERTICAL AND HORIZONTAL MEMBER - POOL BARRIERVERTICAL AND HORIZONTAL MEMBER - POOL BARRIER DATE SCALE DRAWN SHEET REVISIONS BY SHEET TITLE 18 GREEN 2066 LUIS L. AS NOTED 02.24.2023 30 6 S A I N T A N D R E W S R D NE W P O R T B E A C H , C A 9 2 6 6 3 AP N : 0 4 9 - 2 3 0 - 1 1 TR A C T : 1 2 2 0 LO T : 4 4 DATE SCALE DRAWN JOB SHEET REVISIONS BY SHEET TITLE of sheets JO B A D D R E S S LE G A L D E S C R I P T I O N a 02.24.2023 L.L. b -- DRAWINGS PREPARED BY LUIS LOPEZ 03.02.2023 (714) 417-7771 OCBuildersGroup.com PL A N C H E C K N O . c -- 23 2019 CALGREEN RESIDENTIAL MANDATORY MEASURES EFFECTIVE JANUARY 1, 2020 HCD SHL 615 (New 01/20) SECTION REQUIREMENTS Chapter 1 – ADMINISTRATION 101.3.1 Scope Applies to ALL newly constructed residential buildings: low-rise, high-rise, and hotels/motels. 102.3 Requires a completed Residential Occupancies Application Checklist or alternate method acceptable to the enforcing agency to be used for documentation of conformance. Chapter 3 – GREEN BUILDING Additions and alterations 301.1.1 • Applies to additions or alterations of residential buildings where the addition or alteration increases the building’s conditioned area, volume, or size. • Requirements only apply within the specific area of the addition or alteration. Low-rise and high-rise residential buildings 301.2 Banners identify provisions applying to low-rise only [LR] or high-rise only [HR]. Mixed occupancy buildings Requires each portion of mixed occupancy buildings to comply with CALGreen measures applicable for the specific occupancy. Exceptions: 302.1 • Accessory structures and accessory occupancies serving residential buildings to comply with Chapter 4 and Appendix A4, as applicable. • Live/work units complying with the California Building Code Section 419 shall not be considered a mixed occupancy. Live/work units are required to comply with Chapter 4 and Appendix A4, as applicable. Page 1 of 16 SECTION REQUIREMENTS Chapter 4 – RESIDENTIAL MANDATORY MEASURES Division 4.1 – PLANNING AND DESIGN Storm water drainage and retention during construction 4.106.2 Projects which disturb less than 1 acre of soil and are not part of a larger common plan of development shall manage storm water drainage during construction. Grading and paving 4.106.3 Construction plans shall indicate how the site grading or drainage system will manage all surface water flows to keep water from entering buildings. Exception: Additions and alterations which do not alter the existing drainage path. Electric vehicle (EV) charging for new construction • Comply with Section 4.106.4.1, 4.106.4.2 or 4.106.4.3 for future installation and use of EV chargers. • Electric vehicle supply equipment (EVSE) shall be installed in accordance with the California Electrical Code, Article 625. Exceptions: 4.106.4 1. On a case-by-case basis where the local enforcing agency has determined EV charging and infrastructure are not feasible based upon 1 of the following: 1.1. Where there is no commercial power supply. 1.2. Verification that meeting requirements will alter the local utility infrastructure design requirements on the utility side of the meter increasing costs to the homeowner/developer by more than $400.00 per dwelling unit. 2. Accessory Dwelling Units and Junior Accessory Dwelling Units without additional parking facilities. Note: For definitions of Accessory Dwelling Units and Junior Accessory Units, see CALGreen Chapter 2. Page 2 of 16 SECTION REQUIREMENTS EV charging: 1- & 2-family dwellings/townhouses with attached private garages • Install a listed raceway to accommodate a dedicated 208/240-volt branch circuit for each dwelling unit. • Raceway shall not be less than trade size 1 (nominal 1-inch inside diameter). 4.106.4.1 • Raceway shall originate at the main service or subpanel and terminate into a listed cabinet, box or other enclosure in close proximity to the proposed location of an EV charger. • Raceways are required to be continuous at enclosed, inaccessible, or concealed areas and spaces. • Service panel and/or subpanel shall provide capacity to install a 40-ampere minimum dedicated branch circuit and space(s) reserved to permit installation of a branch circuit overcurrent protective device. Identification 4.106.4.1.1 Service panel or subpanel circuit directory shall identify the overcurrent protective device space(s) reserved for future EV charging as “EV CAPABLE”. The raceway termination location shall be permanently and visibly marked as “EV CAPABLE.” EV charging for multifamily dwellings • Applies to all multifamily dwelling units with parking facilities on the site. 4.106.4.2 • 10% of the total number of parking spaces provided for all types of parking facilities, but in no case less than 1, shall be electric vehicle charging spaces (EV spaces) capable of supporting future EVSE. Calculations for the number of EV spaces shall be rounded up to the nearest whole number. Note: Construction documents are intended to demonstrate the project’s capability and capacity for facilitating future EV charging. There is no requirement for EV spaces to be constructed or available until EV chargers are installed for use. Page 3 of 16 SECTION REQUIREMENTS EV charging space (EV space) locations 4.106.4.2.1 Construction documents shall indicate the location of proposed EV spaces. Where common use parking is provided at least 1 EV space shall be located in the common use parking areas and shall be available for use by all residents. EV charging stations (EVCS) When EV chargers are installed, EV spaces (required by Section 4.106.4.2.2, Item 3,) shall comply with at least 1 of the following options: 4.106.4.2.1.1 1. The EV space shall be located adjacent to an accessible parking space meeting the requirements of the California Building Code, Chapter 11A, to allow use of the EV charger from the accessible parking space. 2. The EV space shall be located on an accessible route to the building, as defined in the California Building Code, Chapter 2. Exception: EVCS designed and constructed in compliance with the California Building Code Chapter 11B are not required to comply with Section 4.106.4.2.1.1 and Section 4.106.4.2.2, Item 3. EV charging space (EV space) dimensions 4.106.4.2.2 EV spaces shall be designed to comply with the following: 1. The minimum length of each EV space shall be 18 feet. 2. The minimum width of each EV space shall be 9 feet. 3. 1 in every 25 EV spaces, but not less than 1, shall also have an 8-foot wide minimum aisle. A 5-foot wide minimum aisle shall be permitted provided the minimum width of the EV space is 12 feet. a. Surface slope for this EV space and aisle shall not exceed 1 unit vertical in 48 units horizontal (2.083% slope) in any direction. Page 4 of 16 See specific referenced sections for complete details on CALGreen mandatory requirements. 2019 CALGREEN CODE SECTION REQUIREMENTS Single EV space required • Install a listed raceway capable of accommodating a 208/240-volt dedicated branch circuit. • Raceway shall not be less than trade size 1 (nominal 1-inch inside diameter). 4.106.4.2.3 • Raceway shall originate at the main service or subpanel and shall terminate into a listed cabinet, box or enclosure in close proximity to the proposed location of the EV space. • Construction documents shall identify the raceway termination point. • Service panel and/or subpanel shall provide capacity to install a 40-ampere minimum dedicated branch circuit and space(s) reserved to permit installation of a branch circuit overcurrent protective device. Multiple EV spaces required 4.106.4.2.4 • Construction documents shall indicate the raceway termination point and proposed location of future EV spaces and EV chargers. Construction documents shall also provide information on amperage of future EVSE, raceway method(s), wiring schematics, and electrical load calculations to verify electrical panel service capacity and electrical system, including any on-site distribution transformer(s), have sufficient capacity to simultaneously charge all EVs at all required EV spaces at the full rated amperage of the EVSE. • Plan design shall be based upon a 40-ampere minimum branch circuit. • Required raceways and related components planned to be installed underground, enclosed, inaccessible or in concealed areas and spaces shall be installed at the time of original construction. Identification 4.106.4.2.5 Service panel or subpanel circuit directory shall identify the overcurrent protective device space(s) reserved for future EV charging purposes as “EV CAPABLE” in accordance with the California Electrical Code. Page 5 of 16 SECTION REQUIREMENTS EV charging for hotels and motels 4.106.4.3 • Applies to all newly constructed hotels and motels. • Construction documents shall identify the location of EV spaces. Note: Construction documents are intended to demonstrate the project’s capability and capacity for facilitating future EV charging. There is no requirement for EV spaces to be constructed or available until EV chargers are installed for use. Number of required EV spaces 4.106.4.3.1 Table 4.106.4.3.1 shows the number of required EV spaces based on the total number of parking spaces provided for all types of parking facilities. EV charging space (EV space) dimensions 4.106.4.3.2 EV spaces shall be designed to comply with the following: • Minimum length of each EV space shall be 18 feet. • Minimum width of each EV space shall be 9 feet. Single EV space required (similar to 4.106.4.2.3) • Install a listed raceway capable of accommodating a 208/240-volt dedicated branch circuit. • Raceway shall not be less than trade size 1 (nominal 1-inch inside diameter). 4.106.4.3.3 • Raceway shall originate at the main service or subpanel and shall terminate into a listed cabinet, box or enclosure in close proximity to the proposed location of the EV space. • Construction documents shall identify the raceway termination point. • Service panel and/or subpanel shall provide capacity to install a 40-ampere minimum dedicated branch circuit and space(s) reserved to permit installation of a branch circuit overcurrent protective device. Page 6 of 16 SECTION REQUIREMENTS Multiple EV spaces required (similar to 4.106.4.2.4) 4.106.4.3.4 • Construction documents shall indicate the raceway termination point and proposed location of future EV spaces and EV chargers. Construction documents shall also provide information on amperage of future EVSE, raceway method(s), wiring schematics and electrical load calculations to verify electrical panel service capacity and electrical system, including any on-site distribution transformer(s), have sufficient capacity to simultaneously charge all EVs at all required EV spaces at the full rated amperage of the EVSE. • Plan design shall be based upon a 40-ampere minimum branch circuit. • Required raceways and related components planned to be installed underground, enclosed, inaccessible or, in concealed areas and spaces shall be installed at the time of original construction. Identification (similar to 4.106.4.2.5) 4.106.4.3.5 Service panel or subpanel circuit directory shall identify the overcurrent protective device space(s) reserved for future EV charging purposes as “EV CAPABLE” in accordance with the California Electrical Code. Accessible EV spaces 4.106.4.3.6 In addition to the requirements in Section 4.106.4.3, EV spaces for hotels/motels and all EVSE, when installed, shall comply with the accessibility provisions for EV charging stations in the California Building Code, Chapter 11B. Division 4.2 – ENERGY EFFICIENCY Scope 4.201.1 & 5.201.1 • Standards for residential buildings do not require compliance with levels of minimum energy efficiency beyond those required by the 2019 California Energy Code. Page 7 of 16 • Energy efficiency requirements for low-rise residential (Section 4.201.1) and high- rise residential/hotels/motels (Section 5.201.1) are now in both residential and nonresidential chapters of CALGreen. SECTION REQUIREMENTS Division 4.3 – WATER EFFICIENCY AND CONSERVATION Water conserving plumbing fixtures and fittings Plumbing fixtures and fittings shall comply with the following: 4.303.1.1 − Water closets: ≤ 1.28 gal/flush. 4.303.1.2 − Wall mounted urinals: ≤ 0.125 gal/flush; all other urinals ≤ 0.5 gal/flush. 4.303.1 4.303.1.3.1 − Single showerheads: ≤ 1.8 gpm @ 80 psi. 4.303.1.3.2 − Multiple showerheads: combined flow rate of all showerheads controlled by a single valve shall not exceed 1.8 gpm @ 80 psi, or only 1 shower outlet is to be in operation at a time. 4.303.1.4.1 − Residential lavatory faucets: maximum flow rate ≤ 1.2 gpm @ 60 psi; minimum flow rate ≥ 0.8 gpm @ 20 psi. 4.303.1.4.2 − Lavatory faucets in common and public use areas of residential buildings: ≤ 0.5 gpm @ 60 psi. 4.303.1.4.3 − Metering faucets: ≤ 0.2 gallons per cycle. 4.303.1.4.4 − Kitchen faucets: ≤ 1.8 gpm @ 60 psi; temporary increase to 2.2 gpm allowed but shall default to 1.8 gpm. Standards for plumbing fixtures and fittings 4.303.2 Plumbing fixtures and fittings shall be installed in accordance with the California Plumbing Code, and shall meet applicable standards referenced in Table 1701.1 of the California Plumbing Code. Outdoor potable water use in landscape areas 4.304.1 New residential developments shall comply with a local water efficient landscape ordinance or the current California Department of Water Resources’ Model Water Efficient Landscape Ordinance (MWELO), whichever is more stringent. Division 4.4 – MATERIAL CONSERVATION & RESOURCE EFFICIENCY Rodent proofing 4.406.1 Annular spaces around pipes, electric cables, conduits or other openings in sole/bottom plates at exterior walls shall be closed with cement mortar, concrete masonry or a similar method acceptable to the enforcing agency to prevent passage of rodents. Page 8 of 16 DATE SCALE DRAWN SHEET REVISIONS BY SHEET TITLE 19 GREEN 2066 LUIS L. AS NOTED 02.24.2023 30 6 S A I N T A N D R E W S R D NE W P O R T B E A C H , C A 9 2 6 6 3 AP N : 0 4 9 - 2 3 0 - 1 1 TR A C T : 1 2 2 0 LO T : 4 4 DATE SCALE DRAWN JOB SHEET REVISIONS BY SHEET TITLE of sheets JO B A D D R E S S LE G A L D E S C R I P T I O N a 02.24.2023 L.L. b -- DRAWINGS PREPARED BY LUIS LOPEZ 03.02.2023 (714) 417-7771 OCBuildersGroup.com PL A N C H E C K N O . c -- 23 2019 CALGREEN RESIDENTIAL MANDATORY MEASURES EFFECTIVE JANUARY 1, 2020 HCD SHL 615 (New 01/20) See specific referenced sections for complete details on CALGreen mandatory requirements. 2019 CALGREEN CODE SECTION REQUIREMENTS Construction waste management • Recycle and/or salvage for reuse a minimum of 65% of the nonhazardous construction and demolition waste in accordance with either Section 4.408.2, 4.408.3 or 4.408.4, or meet a more stringent local construction and demolition waste management ordinance. 4.408.1 • Provide documentation to the enforcing agency per Section 4.408.5. Exceptions: 1. Excavated soil and land-clearing debris. 2. Alternative waste reduction methods developed by working with local enforcing agencies if diversion or recycle facilities capable of compliance with this item do not exist or are not located reasonably close to the jobsite. 3. The enforcing agency may make exceptions to the requirements of this section when isolated jobsites are located in areas beyond the haul boundaries of the diversion facility. Construction waste management plan 4.408.2 Submit a construction waste management plan meeting Items 1 through 5 in Section 4.408.2. Plans shall be updated as necessary and shall be available for examination during construction. Waste management company 4.408.3 Utilize a waste management company, approved by the enforcing agency, which can provide verifiable documentation that diverted construction and demolition waste materials meet the requirements in Section 4.408.1. Page 9 of 16 SECTION REQUIREMENTS Waste stream reduction alternative [LR] 4.408.4 & 4.408.4.1 • Projects that generate a total combined weight of construction and demolition waste disposed in landfills, which do not exceed 2 pounds per square foot of the building area, shall meet the minimum 65% construction waste reduction requirement in Section 4.408.1. Operation and maintenance manual 4.410.1 At the time of final inspection, a manual, compact disc, web-based reference or other media acceptable to the enforcing agency which covers 10 specific subject areas shall be placed in the building. Recycling by occupants 4.410.2 Where 5 or more multifamily dwelling units are constructed on a building site, provide readily accessible area(s) that serves all buildings on the site and is identified for the depositing, storage and collection of nonhazardous materials for recycling, including (at minimum) paper, corrugated cardboard, glass, plastics, organic waste, and metals, or meet a lawfully enacted local recycling ordinance, if more restrictive. Exception: Rural jurisdictions that meet and apply for the exemption in Public Resources Code Section 42649.82 (a)(2)(A) et seq. are not required to comply with the organic waste portion of this section. Division 4.5 – ENVIRONMENTAL QUALITY Fireplaces - General 4.503.1 Any installed gas fireplace shall be a direct-vent sealed-combustion type. Any installed woodstove or pellet stove shall comply with U.S. EPA New Source Performance Standards (NSPS) emission limits as applicable, and shall have a permanent label indicating they are certified to meet the emission limits. Woodstoves, pellet stoves, and fireplaces shall also comply with all applicable local ordinances. Page 10 of 16 • Projects that generate a total combined weight of construction and demolition waste disposed in landfills, which do not exceed 3.4 pounds per square foot of the building area shall meet the minimum 65% construction waste reduction requirement in Section 4.408.1. SECTION REQUIREMENTS Protection of mechanical equipment during construction 4.504.1 At the time of rough installation, during storage on the construction site and until final startup of the heating, cooling and ventilating equipment, all duct and other related air intake and distribution component openings shall be covered. Tape, plastic, sheetmetal or other methods acceptable to the enforcing agency to reduce the amount of water, dust and debris entering the system may be used. Adhesives, sealants and caulks Adhesives, sealants and caulks used on the project shall meet the requirements of the following standards unless more stringent local or regional air pollution or air quality management district rules apply: 4.504.2.1 1. Adhesives, adhesive bonding primers, adhesive primers, sealants, sealant primers, and caulks shall comply with local or regional air pollution control or air quality management district rules where applicable or SCAQMD Rule 1168 VOC limits, as shown in Table 4.504.1 or 4.504.2, as applicable. Such products shall also comply with the Rule 1168 prohibition on the use of certain toxic compounds (chloroform, ethylene dichloride, methylene chloride, perchloroethylene and trichloroethylene), except for aerosol products, as specified in Subsection 2. 2. Aerosol adhesives, and smaller unit sizes of adhesives, and sealant or caulking compounds (in units of product, less packaging, which do not weigh more than 1 pound and do not consist of more than 16 fluid ounces) shall comply with statewide VOC standards and other requirements, including prohibitions on use of certain toxic compounds, of California Code of Regulations (CCR), Title 17, commencing with Section 94507. Paints and coatings 4.504.2.2 Architectural paints and coatings shall comply with VOC limits in Table 1 of the Air Resources Board Architectural Suggested Control Measure, as shown in Table 4.504.3, unless more stringent local limits apply. The VOC content limit for coatings that do not meet the definitions for the specialty coatings categories listed in Table 4.504.3 shall be determined by classifying the coating as a Flat, Nonflat, or Nonflat-high Gloss coating, based on its gloss, as defined in subsections 4.21, 4.36, and 4.37 of the 2007 California Air Resources Board, Suggested Control Measure, and the corresponding Flat, Nonflat, or Nonflat-high Gloss VOC limit in Table 4.504.3 shall apply. Page 11 of 16 SECTION REQUIREMENTS Aerosol paints and coatings 4.504.2.3 & 4.504.2.4 • Aerosol paints and coatings shall meet the Product-weighted MIR Limits for ROC in Section 94522(a)(2) and other requirements, including prohibitions on use of certain toxic compounds and ozone depleting substances, in Sections 94522(e)(1) and (f)(1) of California Code of Regulations, Title 17, commencing with Section 94520; and in areas under the jurisdiction of the Bay Area Air Quality Management District shall additionally comply with the percent VOC by weight of product limits of Regulation 8, Rule 49. • Documentation is required per Section 4.504.2.4. Carpet systems Carpet installed in the building interior shall meet the testing and product requirements of 1 of the following: 1. Carpet and Rug Institute’s Green Label Plus Program. 4.504.3 2. California Department of Public Health, “Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers,” Version 1.1, February 2010 (also known as Specification 01350). 3. NSF/ANSI 140 at the Gold level. 4. Scientific Certifications Systems Indoor Advantage™ Gold. Carpet cushion 4.504.3.1 Carpet cushion installed in the building interior shall meet the requirements of the Carpet and Rug Institute’s Green Label program. Carpet adhesive 4.504.3.2 Carpet adhesives shall meet the requirements of Table 4.504.1. Page 12 of 16 SECTION REQUIREMENTS Resilient flooring systems Where resilient flooring is installed, at least 80% of floor area receiving resilient flooring shall comply with 1 or more of the following: 4.504.4 1. Products compliant with the California Department of Public Health, “Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers,” Version 1.1, February 2010 (also known as Specification 01350), certified as a CHPS Low-Emitting Material in the Collaborative for High Performance Schools (CHPS) High Performance Products Database. 2. Products certified under UL GREENGUARD Gold (formerly the Greenguard Children & Schools program). 3. Certification under the Resilient Floor Covering Institute (RFCI) FloorScore program. 4. Meet the California Department of Public Health, “Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers,” Version 1.1, February 2010 (also known as Specification 01350). Composite wood products • Hardwood plywood, particleboard and medium density fiberboard composite wood products used on the interior or exterior of the building shall meet the requirements for formaldehyde as specified in the Air Resources Board’s Air Toxics Control Measure for Composite Wood (17 CCR 93120 et seq.), as shown in Table 4.504.5. 4.504.5 & 4.504.5.1 • Definition of Composite Wood Products: Composite wood products include hardwood plywood, particleboard, and medium density fiberboard. “Composite wood products” do not include hardboard, structural plywood, structural panels, structural composite lumber, oriented strand board, glued laminated timber, prefabricated wood I-joists, or finger-joined lumber, all as specified in CCR, Title 17, Section 93120.1(a). Page 13 of 16 • Documentation is required per Section 4.504.5.1. SECTION 4.505.2 REQUIREMENTS Concrete slab foundations Concrete slab foundations or concrete slab-on-ground floors required to have a vapor retarder by the California Building Code, Chapter 19, or the California Residential Code, Chapter 5, respectively, shall also comply with this section. Capillary break A capillary break shall be installed in compliance with at least 1 of the following: 4.505.2.1 1. A 4-inch thick base of ½ inch or larger clean aggregate shall be provided with a vapor retarder in direct contact with concrete and a concrete mix design, which will address bleeding, shrinkage, and curling, shall be used. For additional information, see American Concrete Institute, ACI 302.2R-06. 2. Other equivalent methods approved by the enforcing agency. 3. A slab design specified by a licensed design professional. Moisture content of building materials Building materials with visible signs of water damage shall not be installed. Wall and floor framing shall not be enclosed when the framing members exceed 19% moisture content. Moisture content shall be verified in compliance with the following: 1. Moisture content shall be determined with either a probe-type or a contact-type moisture meter. Equivalent moisture verification methods may be approved by the enforcing agency and shall satisfy requirements in Section 101.8. 4.505.3 2. Moisture readings shall be taken at a point 2 feet to 4 feet from the grade stamped end of each piece to be verified. 3. At least 3 random moisture readings shall be performed on wall and floor framing with documentation acceptable to the enforcing agency provided at the time of approval to enclose the wall and floor framing. Insulation products which are visibly wet or have a high moisture content shall be replaced or allowed to dry prior to enclosure in wall or floor cavities. Manufacturers’ drying recommendations shall be followed for wet-applied insulation products prior to enclosure. Page 14 of 16 SECTION REQUIREMENTS Bathroom exhaust fans Each bathroom shall be mechanically ventilated and shall comply with the following: 1. Fans shall be ENERGY STAR compliant and be ducted to terminate outside the building. 4.506.1 2. Unless functioning as a component of a whole house ventilation system, fans must be controlled by a humidity control. a. Humidity controls shall be capable of manual or automatic adjustment between a relative humidity range of ≤ 50% to a maximum of 80%. b. A humidity control may be a separate component to the exhaust fan and is not required to be integral or built-in. Note: For CALGreen, a bathroom is a room which contains a bathtub, shower, or tub/shower combination. Fans or mechanical ventilation is required in each bathroom. Heating and air-conditioning system design Heating and air-conditioning systems shall be sized, designed and equipment selected using the following methods: 1. The heat loss and heat gain is established according to ANSI/ACCA 2 Manual J – 2016 (Residential Load Calculation), ASHRAE handbooks or other equivalent design software or methods. 4.507.2 2. Duct systems are sized according to ANSI/ACCA 1 Manual D – 2016 (Residential Duct Systems), ASHRAE handbooks or other equivalent design software or methods. 3. Select heating and cooling equipment according to ANSI/ACCA 3 Manual S – 2014 (Residential Equipment Selection) or other equivalent design software or methods. Exception: Use of alternate design temperatures necessary to ensure the systems function are acceptable. Page 15 of 16 SECTION REQUIREMENTS CHAPTER 7 – INSTALLER & SPECIAL INSPECTOR QUALIFICATIONS Installer training HVAC system installers shall be trained and certified in the proper installation of HVAC systems and equipment by a recognized training or certification program. Examples of acceptable HVAC training and certification programs include, but are not limited to, the following: 702.1 1. State certified apprenticeship programs. 2. Public utility training programs. 3. Training programs sponsored by trade, labor or statewide energy consulting or verification organizations. 4. Programs sponsored by manufacturing organizations. 5. Other programs acceptable to the enforcing agency. Special inspection 702.2 When required by the enforcing agency, special inspectors must be qualified and able to demonstrate competence to the enforcing agency in the discipline in which they are inspecting. Documentation 703.1 Documentation of compliance shall include, but is not limited to, construction documents, plans, specifications, builder or installer certification, inspection reports, or other methods acceptable to the local enforcing agency. Other specific documentation or special inspections necessary to verify compliance are specified in appropriate sections of CALGreen. Page 16 of 16 REVISIONS BY REVISIONS BY REVISIONS BY REVISIONS BY