HomeMy WebLinkAboutPA2023-0017_20230120_CDP First Submittal 42x30DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
SHEET LISTCODE INFORMATIONSITE INFORMATIONPROJECT STATISTICSDEFERRED SUBMITTALSPROJECT DESCRIPTION
VICINITY MAP ZONING STANDARDS SHORING & EXCAVATION AGENCIES & SERVICES PROJECT DIRECTORY
13
24
58
79
1012
11
BR
A
N
D
O
N
ARCHITECT
STRUCTURAL ENGINEER
INTERIOR DESIGNER
ENERGY CONSULTANT
BRANDON ARCHITECTS, INC.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
P: 714.454.4040
WWW.BRANDONARCHITECTS.COM
OWNER
CIVIL ENGINEER
LANDSCAPE DESIGNER
MEP CONSULTANT
GENERAL CONTRACTOR
GEOTECHNICAL ENGINEER
SURVEYOR
AR
C
H
I
T
E
C
T
S
,
I
N
C
.
BRANDON ARCHITECTS
SPECIAL INSPECTIONS6
01/20/2023
TITLE SHEET
MI
L
L
E
R
R
E
S
I
D
E
N
C
E
MR. & MRS. MATTHEW MILLER
22 BAY ISLAND,
NEWPORT BEACH, CA 92661
P: 949.235.9286
millermg123@gmail.com
CDP
22 BAY ISLAND
NEWPORT BEACH, CA 92661
T-1.0
MILLER RESIDENCE
22 BAY ISLAND
NEWPORT BEACH, CA 92661
TBD
BRIAN JOWETT
MR. & MRS. MATTHEW MILLER
22 BAY ISLAND,
NEWPORT BEACH, CA 92661
P: 949.235.9286
millermg123@gmail.com
TBD
SKELLY ENGINEERING
DAVID SKELLY
1771 TATTENHAM ROAD,
ENCINITAS, CA 92024
P: 619.995.8378
dskelly@geosoilsinc.com
APEX LAND SURVEYING, INC.
PAUL CRAFT, LLC. NO. 8516
HUNTINGTON BEACH, CA 92646
P: 714.488.5006
F: 714.333.4440
MIRAGE LANDSCAPE
JOSEPH SEKANDER
620 1/2 AVOCADO AVE.
CORONA DEL MAR, CA 92625
P: 949.768.4300
joseph@miragelandscape.com
TBD
TBD CIVILSPACES ENGINEERING, INC
WILLIAM ROLPH
28052 CAMINO CAPISTRANO, SUITE 213
LAGUNA NIGUEL, CA 92677
P: 949.464.8115
will@civilspaces.com
TBD TBD
BUILDING AREA SCHEDULE
NAME AREA
FIRST FLOOR 1876 SF
SECOND FLOOR 2063 SF
THIRD FLOOR 337 SF
LIVING SUB TOTAL 4276 SF
CART GARAGE 279 SF
GARAGE SUB TOTAL 279 SF
GRAND TOTAL 4555 SF
LEGAL DESCRIPTION:
LOT INFORMATION:
ZONED: RM MULTIPLE RESIDENTIAL
(PROJECT CONFORMS TO APPLICABLE SECTIONS OF THE
CERTIFIED LOCAL COASTAL PROGRAM, PRD #3618) REFER
TO 9/T-1.0 FOR TITLE 21 RM DEVELOPMENT STANDARDS.
SITE AREA:4,544 S.F.
BUILDABLE AREA (HOA & UP3618): 2,290 S.F.
TOTAL ALLOWABLE AREA (HOA & UP3618): 2.5 x 2,290 S.F. = 5,725 S.F.
THIRD LEVEL ALLOWABLE AREA: 2,290 S.F. x .15 = 343.5 S.F.
FLAT ROOF ALLOWABLE AREA: 2,290 S.F. x .15 = 343.5 S.F.
EXISTING BUILDING INFORMATION:
EXISTING SINGLE FAMILY TO BE DEMOLISHED
EXISTING S.F. = 3,662 S.F.
ZONING INFORMATION:
SETBACKS FROM BUILDING SITE BOUNDARY
(PER USE PERMIT NO. 3618)
FRONT SETBACK (BAYSIDE): 4 FT.
REAR SETBACK (PARKSIDE): 18 FT.
LEFT SETBACK: 5 FT. OR 8 FT.
RIGHT SETBACK: 11 FT.
(SEE SITE PLAN FOR ADDTITIONAL INFO.)
APN: 048-040-02
PARCEL 22, BAY ISLAND, PORTIONS OF LOT 5, SEC. 34
CITY OF NEWPORT BEACH, COUNTY OF ORANGE, STATE OF CALIFORNIA
CODES:NBMC TITLE 21 AND EXISTING USE PERMIT 3618
NBMC (NEWPORT BEACH MUNICIPAL CODE) CALIFORNIA CODES:
2022 CRC, 2022 CFC, 2022 CEC, 2022 CPC, AND 2022 CMC, 2022 CAL GREEN
OCCUPANT LOAD 1 UNIT
OCCUPANCY CLASSIFICATION R-3/U
OCCUPANCY SEPARATION (GARAGE)1-HR.
FLOOR & FLOOR-CEILING N/A.
TYPE OF CONSTRUCTION VB -SPRINKLERED
FIRE SPRINKLER YES
HEIGHT 3 -LEVELS
FLOOR AREA REF. 8/T-1.0
ALLOWABLE BLDG. ARE (PER CBC TBL. 503)N/A.
DIG ALERT:1.800.227.2600
SOUTHERN CALIFORNIA EDISON:1.714.895.0246
SOUTHERN CALIFORNIA GAS:1.800.427.2000
CITY WATER & SEWER:1.949.644.3011
PACIFIC BELL TELEPHONE:1.800.750.2355
CITY OF NEWPORT BEACH
PUBLIC WORKS DEPT.:1.949.644.3311
CITY OF NEWPORT BEACH PLANNING DEPT.:
GENERAL INFOMATION:1.949.644.3200
ZONING INFORMATION:1.949.644.3204
CITY OF NEWPORT BEACH BUILDING DEPT.:
GENERAL:1.949.644.3275
PERMITS:1.949.644.3288
INSPECTIONS:1.949.644.3255
NEWPORT BEACH FIRE DEPARTMENT:1.949.644.3106
ORANGE COUNTY HEALTH SERVICES:1.714.834.3882
1.A CAL-OSHA PERMIT IS REQUIRED FOR EXCAVATIONS DEEPER THAN 5' AND FOR SHORING AND UNDERPINNING.
CONTRACTOR TO PROVIDE A COPY OF OSHA PERMIT.
2.CONTRACTOR SHALL USE THE CITY STANDARD FORM '30-DAY NOTICE OF INTENT TO EXCAVATE' TO NOTIFY ADJACENT
PROPERTY OWNERS BY CERTIFIED MAIL 30-DAYS PRIOR TO STARTING EXCAVATION OR SHORING. CITY STANDARD FORM
CAN BE OBTAINED AT:
HTTP://WWW.NEWPORTBEACHCA.GOV/HOME/SHOWDOCUMENT?ID=17395
1.REF. STRUCTURAL DRAWINGS FOR SPECIAL INSPECTIONS BY ENGINEER OF RECORD
2.HERS VERIFICATION REQUIRED, REF. ENERGY CALCULATIONS
1. LANDSCAPE PLAN; BBQ; FIRE PIT; ACCESSORY STRUCTURES, MASONRY OR CONCRETE WALLS/FENCES; RETAINING WALLS OVER 4
FT. HIGH FROM THE BOTTOM OF THE FOUNDATION TO THE TOP OF WALL; UNDER SEPERATE REVIEWS AND PERMITS (FOR H.O.A.
PURPOSES).
2. POOLS, SPAS, WALLS, FENCES, PATIO COVERS AND OTHER FREESTANDING STRUCTURES REQUIRE SEPARATE REVIEWS AND
PERMITS.
3. SUBMIT SOUND ATTENUATION DESIGN FOR HVAC EQUIPMENT PER ARI STD. 275. SOUND LEVEL NOT TO EXCEED 50dBA (55dBA
WITH TIMER, 65dBA WITH TIMER AND NEIGHBORS CONSENT). LOCATION OF MEASUREMENT TO BE AT ADJACENT PROPERTY PATIO
OR OPENING.
4. FIRE SPRINKLERS REQUIRED, CONSTRACTOR TO SUBMIT FIRE SPRINKLER DRAWINGS FOR ARCHITECT'S APPROVAL PRIOR TO
SUBMITTING TO CITY. OBTAIN FIRE SPRINKLER PERMIT PRIOR TO CALLING FOR ROOF SHEATHING INSPECTION.
5. A NOTICE OF INTENT TO DEMOLISH SHALL BE SENT VIA CERTIFIED MAIL TO ADJACENT PROPERTY OWNER(S). SIGNED RETURNED
RECEIPT MUST BE PROVIDED TO THE BUILDING DIVISION AT THE TIME OF PERMIT ISSUANCE. DEMOLITION MAY COMMENCE 30
DAYS AFTER THE DATE OF NOTIFICATION PER NEWPORT BEACH MUNICIPAL CODE SECTION 15.02.120.
6. PV SOLAR SYSTEM (MIN. 4.3KW DC) + 5 KWH BATTERY SYSTEM PER T-24
7. ELEVATOR
NOTE: DEFERRED SUBMITTALS TO BE REVIEWED BY PROJECT ARCHITECT OR ENGINEER OF RECORD AND CERTIFIED PRIOR TO
SUBMITTAL TO LOCAL AGENCY FOR REVIEW.
C.N.B. NOTE: BRANDON ARCHITECTS, INC. IS THE DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE OF THE PROJECT, RESPONSIBLE
FOR REVIEWING AND COORDINATING SUBMITTAL DOCUMENTS PREPARED BY OTHERS, INCLUDING PHASED AND DEFERRED
SUBMITTAL ITEMS, FOR COMPATIBILITY WITH THE DESIGN OF THE BUILDING. (NBMC 15.02.010)
THE SUBJECT PROPERTY IS LOCATED IN NEWPORT BEACH, CA IN THE AREA KNOWN AS THE BAY ISLAND (LOT 22) ON THE
EAST SIDE. THE BUILDING SITE IS APPROXIMATE 56’WIDE BY 94’DEEP, IT IS ZONED RM AND IS APPROXIMATELY 4,544 S.F.
THE PROPERTY INCLUDES AN EXISTING 2-STORY SINGLE FAMILY RESIDENCE TO BE DEMOLISHED. TWO OFFSITE PARKING
SPACES ARE PROVIDED IN THE PARKING GARAGE LOCATED AT 501 W. BAY AVE,. NEWPORT BACK PER USE PERMIT 3618.
THE CLIENT PROPOSES TO BUILD A 3-STORY RESIDENCE OF APPX. 4,555 S.F. WHICH WILL INCLUDE A GOLF CART GARAGE
OF APPX. 279 S.F. TO BE WOOD FRAMED WITH A SLAB FOUNDATION. THE RESIDENCE CONSIST OF A MASTER SUITE, BATH
AND WALK-IN-CLOSET, 3 SECONDARY BEDROOMS WITH ATTACHED BATHS, A BUNK ROOM WITH AN ATTACHED BATH, A
STUDY AREA, GREAT ROOM, DINING AREA, LARGE EAT-IN KITCHEN WITH A PANTRY, LAUNDRY ROOM/GYM, A POWDER
BATH, AND A ROOF LOUNGE WITH AN ATTECTHED POWDER BATH ON THE THIRD FLOOR. OUTDOOR SPACES INCLUDING
ENTRY, DECK, OUTDOOR DINING, BALCONIES, AND ROOF DECK WILL BE MAXIMIZED AND INTEGRATED INTO THE MODERN
PLAN TO ACHIEVE INDOOR/OUTDOOR LIVING SPACES AND TO MAXIMIZE OCEAN/BAY VIEWS. THE PROJECT WILL BE A
CONTEMPORARY TAKE ON SPANISH RESIDENTIAL DESIGN AND THE EXTERIOR WILL BE PRIMARILY STUCCO AND STONE
SIDING. BUILDING COMPONENTS AND MATERIALS WILL BE OF HIGH QUALITY AND DURABLE.
SITE
NEWPORT BAY
ISLAND AVE.
OFFSITE PARKING:BAY ISLAND IS A SINGLE LEGAL LOT, PERMIT NO. 3618 AUTHORIZED OFF-SITE PARKING FOR BAY ISLAND
REQUIRING 48 PARKING SPACES FOR THE DEVELOPMENT OF 24 HOMES ON THE ISLAND. A PARKING MANAGEMENT PLAN
INCLUDES THE USE OF TWO OFF-SITE PARKING SPACES IN THE EXISTING 49-SPACE PARKING STRUCTURE OWNED IN COMMON BY
BAY ISLAND RESIDENTS LOCATED AT 501 W. BAY AVENUE. THE PARKING MANAGEMENT PLAN ALSO INCLUDES A REQUIREMENT
TO PROVIDE ONE ENCLOSED GOLF CART STORAGE SPACE ONSITE. THEREBY, THE PROJECT PROVIDES (3) SPACES TOTAL FOR THE
PROPOSED UNIT CONSISTENT WITH NBMC SECTION 21.40.040.
ZONE STANDARDS (BUILDING SITE) PER UP3618
DESCRIPTION REQUIRED/ALLOWED EXISTING PROPOSED CONFORMS (YES/NO)
USE
ZONE
ALLOWABLE AREA
MAX. BUILDING HEIGHT
RESIDENTIAL
RM
5,725 SF
33' -0" (SLOPED ROOF)
RESIDENTIAL
RM
3,662 SF
<33' -0"
RESIDENTIAL
RM
4,555 SF
32' -4 5/8"
Y
Y
Y
Y
Y
NO. REVISION DATE
MAX. FLAT AREA 343.5 S.F.N/A.269 S.F.Y
THIRD FLOOR AREA 343.5 S.F.N/A.337 S.F.Y
THIRD LEVEL AREA SCHEDULE
NAME AREA
THIRD FLOOR 337 SF
LIVING SUB TOTAL 337 SF
ROOF DECK 219 SF
MECH WELL 50 SF
OUTDOOR SUB TOTAL 269 SF
GRAND TOTAL 606 SF
OUTDOOR AREA SCHEDULE
NAME AREA
DECK 590 SF
MASTER BALCONY 128 SF
BALCONY #2 40 SF
BALCONY #3 40 SF
ROOF DECK 219 SF
MECH WELL 50 SF
GRAND TOTAL 1067 SF
BUILDABLE AREA 2,290 SF 2,143 SF 2,155 SF
T-1.0 TITLE SHEET
T-1.1 ARCHITECTURAL GENERAL NOTES
T-1.2 SUPPLEMENTAL DOC. & NOTES
SUR TOPOGRAPHIC SURVEY
A-0.0 ARCHITECTURAL SITE PLAN
A-0.2 DEMO PLAN
A-0.3 AREA PLANS
C1 TITLE SHEET
C2 GRADING PLAN
C3 CONSTRCUTION POLLUTION PREVENTION PLAN
L-1 HARDSCAPE PLAN
L-2 PLANTING PLAN
L-3 LIGHTING PLAN
A-1.0 3D VIEWS
A-2.0 FIRST LEVEL FLOOR PLAN
A-2.1 SECOND LEVEL FLOOR PLAN
A-2.2 THIRD LEVEL FLOOR PLAN
A-2.3 FIRST LEVEL DIMENSION PLAN
A-2.4 SECOND LEVEL DIMENSION PLAN
A-2.5 THIRD LEVEL DIMENSION PLAN
A-3.0 ROOF PLAN
A-4.0 EXTERIOR ELEVATIONS
A-4.1 EXTERIOR ELEVATIONS
A-5.0 BUILDING SECTIONS
DEFINITIONS: (AS USED IN THESE SPECIFICATIONS)
OWNER SHALL MEAN: MATTHEW & SHERYLAN MILLER
ARCHITECT SHALL MEAN: BRANDON ARCHITECTS, INC., CHRISTOPHER BRANDON
CONTRACTOR SHALL MEAN:LICENSED GENERAL CONTRACTOR HIRED TO PERFORM THE WORK UNDER THIS CONTRACT
SPECIFICATIONS SHALL MEAN:WRITTEN SPECIFICATIONS IN THE PLANS OR THE "PROJECT MANUAL" (IF PROVIDED FOR THIS PROJECT)
CONTRACT DOCUMENTS SHALL MEAN: WORKING DRAWINGS APPROVED FOR BUILDING PERMIT, PLUS ANY CHANGE ORDERS OR ADDENDA TO SAME.
ARCHITECTURAL GENERAL NOTES:
1. CODES/GENERAL PROVISIONS: ALL WORK, CONSTRUCTION AND MATERIALS SHALL COMPLY WITH ALL PROVISIONS OF THE APPLICABLE BUILDING CODES AND WITH OTHER RULES, REGULATIONS AND ORDINANCES GOVERNING THE PLACE OF
CONSTRUCTION. IT IS THE RESPONSIBILITY OF THE CONTRACTOR, SUB-CONTRACTORS, AND ANYONE SUPPLYING LABOR AND/OR MATERIAL TO BRING TO THE ATTENTION OF THE ARCHITECT (VERBALLY AND IN WRITING) ANY KNOWN DISCREPANCIES OR
CONFLICT BETWEEN THE REQUIREMENTS OF THESE CODES AND THE CONTRACT DOCUMENTS (DRAWINGS). THE APPLICABLE CODES SHALL INCLUDE, BUT SHALL NOT BE LIMITED TO THOSE AS LISTED IN "CODE REVIEW" BOX. (T-1.0)
ALL WORK SHALL BE PERFORMED SO AS TO COMPLY WITH ALL LEGAL AND INDUSTRY REQUIREMENTS AND STANDARDS INCLUDING THE FOLLOWING:
-THE CALIFORNIA BUILDING CODES, 2019 EDITIONS, AND ALL APPLICABLE RELATED SPECIALTY CODES.
-THE FUNCTIONALITY STANDARDS SET FORTH IN TITLE 7 OF THE CALIFORNIA CIVIL CODE (THE "RIGHT TO REPAIR ACT").
-THE CITY OF NEWPORT BEACH MUNICIPAL CODE INCLUDING ANY WORK TIME RESTRICTION AND ANY AMENDMENT TO CALIFRONIA BUILDING CODES.
-THE MANUFACTURER'S REQUIREMENTS OF RECOMMENDATIONS FOR ANY INCORPORATED PRODUCTS.
2. FEES: CONTRACTOR AND HIS SUB-CONTRACTORS SHALL OBTAIN AND PAY FOR ALL PERMITS, LICENSES, CONSTRUCTION TAXES AND FEES REQUIRED BY CITY, COUNTY AND STATE LAWS EXCEPT THE GENERAL BUILDING PLAN CHECK FEE AND REQUIRED
REFUNDABLE DEPOSITS WHICH WILL BE PAID BY THE OWNER. CONTRACTOR SHALL ARRANGE FOR ALL METER INSTALLATIONS AND PAY ALL FEES FOR SAID METERS. CONTRACTOR SHALL PROVIDE TEMPORARY TOILET FACILITIES AND EROSION CONTROL
MEASURES AS REQUIRED BY STATE AND LOCAL BUILDING CODE.
3. CONTRACTOR'S SURVEY: CONTRACTOR SHALL VISIT THE JOB SITE AND BE RESPONSIBLE FOR HAVING COMPLETE KNOWLEDGE OF EXISTING CONDITIONS. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS WITH THOSE SHOWN ON THE DRAWINGS AND
SHALL VERIFY GRADES, CONDITIONS AND DIMENSIONS PRIOR TO COMMENCING DEMOLITION AND CONSTRUCTION. CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY VERBALLY AND IN WRITING OF DISCREPANCIES BETWEEN ACTUAL CONDITIONS AND
THOSE DEPICTED IN THE CONTRACT DOCUMENTS. CONTRACTOR SHALL NOTIFY ARCHITECT IMMEDIATELY VERBALLY AND IN WRITING OF ANY DISCREPANCIES FOUND WITHIN THE DRAWINGS AND SPECIFICATIONS.
4. COORDINATION OF CONSTRUCTION: CONTRACTOR IS SOLELY RESPONSIBLE FOR THE ACCURACY OF DETAILS; FOR CONFIRMING AND COORDINATING ALL QUANTITIES AND DIMENSIONS; FOR SELECTING FABRICATION PROCESSES; FOR TECHNIQUES OF
ASSEMBLY AND PERFORMANCE OF ALL WORK IN A SAFE AND SATISFACTORY MANNER. CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF ALL WORK INCLUDING THAT OF THE SUB-CONTRACTORS. CONTRACTOR SHALL PROVIDE SUPERVISION OF
THE JOB DURING ALL PHASES OF CONSTRUCTION ACTIVITIES. A COMPETENT SUPERINTENDENT SHALL BE SELECTED BY THE CONTRACTOR AND SHALL BE IN CHARGE OF THE JOB UNTIL ITS COMPLETION. CONTRACTOR AGREES TO BIND EVERY SUB-
CONTRACTOR BY THE TERMS OF THE CONTRACT AS FAR AS SUCH TERMS ARE APPLICABLE TO THE SUB-CONTRACTOR'S WORK.
5. CLEAN-UP: ALL SUBCONTRACTORS SHALL BE RESPONSIBLE FOR THE DAILY REMOVAL OF ALL DEBRIS ACCUMULATED AS A RESULT OF THEIR OPERATIONS. ALL SCRAP DEBRIS AND OTHER EXCESS MATERIAL SHALL BE LAWFULLY REMOVED FROM THE SITE,
UNLESS OTHERWISE DIRECTED BY THE CONTRACTOR.
6. TESTS AND PERMITS: CONTRACTOR SHALL ARRANGE FOR, AND SECURE REQUIRED TESTS, PERMITS AND INSPECTIONS, AND SHALL BEAR COSTS FOR SAME.
7. GUARANTEES: CONTRACTOR SHALL GUARANTEE ALL WORK, MATERIALS AND PRODUCTS FOR ONE YEAR AFTER THE DATE OF ACCEPTANCE OF THE WORK AND CONTRACTOR SHALL REPAIR OR REPLACE, OR CAUSE TO BE REPAIRED OR REPLACED ANY OR ALL
SUCH WORK TOGETHER WITH ANY OTHER WORK WHICH MAY BE DISPLACED IN DOING SO, THAT MAY PROVE DEFECTIVE WITHIN ONE YEAR, WITHOUT ADDITIONAL EXPENSE; ORDINARY WEAR AND TEAR, UNUSUAL ABUSE OR NEGLECT IS EXCEPTED. EXCEPTIONS
TO ONE YEAR GUARANTEE ARE SPECIFIED IN OTHER SECTIONS OF THE PROJECT MANUAL OR DRAWINGS. STATE LAW, OR MANUFACTURER'S GUARANTEE SHALL GOVERN IF LENGTH AND TYPES OF GUARANTEES ARE MORE STRICT OR FOR LONGER PERIODS. IT IS
UNDERSTOOD BY CONTRACTOR THAT IT IS HIS RESPONSIBILITY TO PROVIDE MATERIALS AND CONSTRUCTION WHICH WILL YIELD A REASONABLE VALUE OVER A PERIOD OF TIME WHICH MAY EXCEED THE SPECIFIED GUARANTEE AND WARRANTY PERIODS.
CONTRACTOR SHALL BE RESPONSIBLE FOR A WEATHER TIGHT BUILDING, FREE FROM DEFECTS OF MATERIALS AND WORKMANSHIP. EACH SUB-CONTRACTOR SHALL PROVIDE A WRITTEN GUARANTEE STATING THAT WORK EXECUTED BY HIM IS FREE AND WILL
REMAIN FREE FROM DEFECTS OF MATERIALS AND WORKMANSHIP FOR ONE YEAR FROM DATE OF ACCEPTANCE OF HIS WORK BY OWNER, AND THAT REPAIR AND REPLACEMENT OF SUCH DEFECTIVE WORK AND ALL OTHER WORK DAMAGED AS A RESULT THEREBY
WILL BE EXECUTED IN A TIMELY MANNER AT THE CONVENIENCE OF THE OWNER AND WITHOUT COST TO OWNER.
8. WAIVER OF LIENS: CONTRACTOR SHALL PROVIDE CERTIFIED RELEASE OF LIENS BY ALL SUBCONTRACTORS AND SUPPLIERS, OR ANYONE PROVIDING MATERIALS AND/OR LABOR AS THEY BECOME AVAILABLE.
9. ROLL OF ARCHITECT DURING CONSTRUCTION: THE ARCHITECT WILL NOT ACT AS THE OWNER'S REPRESENTATIVE DURING CONSTRUCTION. ARCHITECT WILL ADVISE AND CONSULT WITH OWNER. ARCHITECT WILL OBSERVE CONSTRUCTION PER HIS/HER
AGREEMENT WITH OWNER AND RENDER INTERPRETATIONS NECESSARY FOR THE PROPER EXECUTION OR PROGRESS OF THE WORK IN ACCORDANCE WITH THE INTENT OF THE PLANS AND SPECIFICATIONS. ARCHITECT WILL NOT BE RESPONSIBLE OR HAVE
CONTROL OR CHARGE OVER THE ACTS OR OMISSIONS, CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS, OF THE CONTRACTOR, SUB-CONTRACTORS, OR ANY OF THEIR AGENTS OR
EMPLOYEES, OR ANY OTHER PERSONS PERFORMING ANY OF THE WORK. ANY VERBAL INSTRUCTION OR AUTHORIZATION THAT IS CONFIRMED BY LETTER, MEETING NOTE, MEMORANDA, OR THE LIKE, (WITH A COPY SENT TO THE OWNER, OR THE OWNER'S
REPRESENTATIVE) & THERE IS NO EXCEPTION TAKEN WITHIN (10) CALENDAR DAYS, SHALL BE DEEMED EQUIVALENT TO RECEIPT OF WRITTEN INSTRUCTION, APPROVAL AND AUTHORIZATION FROM THE OWNER.
10. A.I.A. GENERAL CONDITIONS: THE CURRENT GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION PUBLISHED BY THE AMERICAN INSTITUTE OF ARCHITECTS SHALL APPLY AS THOUGH IT WERE PART OF THESE DOCUMENTS UNLESS SPECIFICALLY
MODIFIED IN THE OWNER/CONTRACTOR AGREEMENT. A COPY OF SAID GENERAL CONDITIONS MAY BE OBTAINED FROM THE ARCHITECT UPON REQUEST. THE NOTES CONTAINED IN THESE "GENERAL NOTES" ON THIS SHEET ARE INTENDED TO SUMMARIZE AND
COMPLIMENT THE A.I.A. GENERAL CONDITIONS. THE A.I.A. GENERAL CONDITIONS SHALL TAKE PRECEDENCE OVER THESE NOTES SHOULD A CONFLICT IN WORDING OCCUR.
11. EXTRAS: OWNER MAY ORDER EXTRA WORK OR MAKE CHANGES BY ALTERING, ADDING TO OR DEDUCTING FROM THE WORK, THE CONTRACT SUM BEING ADJUSTED TO THE MUTUAL SATISFACTION OF THE OWNER AND CONTRACTOR. BEFORE ANY CHANGES
ARE BEGUN, THE ADDED OR DEDUCTED SUM SHALL BE PRESENTED TO OWNER IN WRITING FOR APPROVAL.
12. SUBSTITUTIONS: SUBSTITUTIONS OF MATERIALS OR METHODS PROPOSED BY THE CONTRACTOR OR HIS SUB-CONTRACTORS CONTRARY TO DRAWINGS AND SPECIFICATIONS SHALL BE SUBMITTED TO ARCHITECT IN WRITING FOR APPROVAL OR DENIAL. IF
MORE THAN ONE MANUFACTURER IS SPECIFIED IN THE PLANS OR SPECIFICATIONS, IT SHALL BE THE CONTRACTOR'S OPTION TO SELECT THE ONE WHICH HE MAY DESIRE. IF MORE THAN ONE FINISH OR STYLE IS AVAILABLE IN THE ITEM SPECIFIED, CONTRACTOR
SHALL BE OBLIGATED TO NOTIFY ARCHITECT VERBALLY AND IN WRITING OF THIS FACT FOR ARCHITECT'S AND OWNER'S DECISION. WHERE THE TERM "OR EQUAL" IS USED IN DRAWINGS OR SPECS IT SHALL BE UNDERSTOOD THAT THE REFERENCE IS MADE
SUBJECT TO THE RULING AND JUDGMENT OF THE ARCHITECT AND SHALL BE SUBMITTED TO THE ARCHITECT FOR REVIEW AND APPROVAL. ACTUAL SAMPLES OF THE SUBSTITUTIONS SHALL ALSO BE SUBMITTED TO THE ARCHITECT FOR REVIEW AND APPROVAL.
13. INSURANCE: CONTRACTOR SHALL CARRY GENERAL LIABILITY INSURANCE WITH BROAD FORM PROPERTY DAMAGE ENDORSEMENT AND CONTINGENT LIABILITY ENDORSEMENT. OWNER AND ARCHITECT SHALL BE LISTED AS ADDITIONAL INSURERS UNDER
THE POLICY WITH WAIVER OF SUBROGATION. CONTRACTOR SHALL FURNISH OWNER WITH A CERTIFICATE OF INSURANCE WITH A 30 DAY NOTICE OF CANCELLATION. OWNER SHALL OBTAIN A BUILDER'S RISK POLICY WITH ARCHITECT NAMED AS AN ADDITIONAL
INSURED WITH WAIVER OF SUBROGATION.
14. SCOPE OF DRAWINGS AND SPECIFICATIONS: THESE DRAWINGS AND SPECIFICATIONS SHALL BE INTENDED TO SHOW AND DESCRIBE DETAILS FOR A CONSTRUCTIBLE BUILDING. PARTS AND DETAILS NOT FULLY SHOWN OR DESCRIBED SHALL BE DETAILED
AND EXECUTED ACCORDING TO STANDARD FIRST CLASS PRACTICE AND IN SIMILAR MANNER AND SPIRIT OF THE DETAILS WHICH ARE SHOWN ON THE DRAWINGS AND/OR DESCRIBED IN THE PROJECT MANUAL. IF CONTRACTOR OR SUB-CONTRACTOR FINDS ANY
DETAILS WHICH, IN HIS OPINION, ARE UNSOUND, UNSAFE, OR NOT WATERPROOF, IT IS HIS DUTY TO NOTIFY ARCHITECT IN WRITING OF THIS FACT. IF WORK IS PERFORMED AS DETAILED, IT WILL BE ASSUMED THAT THERE ARE NO OBJECTIONS TO THE DETAIL.
ACCURACY OF ALL DIMENSIONS SHALL BE CHECKED. NO EXTRA COMPENSATION WILL BE ALLOWED FOR DIFFERENCE BETWEEN ACTUAL DIMENSIONS AND THOSE INDICATED ON THE DRAWINGS. IN USING THESE PLAN FOR BIDDING OR CONSTRUCTION
PURPOSES, ALL CONTRACTORS ARE REQUIRED TO REVIEW AND TREAT THEM AS A WHOLE IN ORDER TO IDENTIFY ALL REQUIREMENTS THAT DIRECTLY OR INDIRECTLY AFFECT THEIR PORTION OF THE WORK, EVEN REQUIREMENTS LOCATED IN SECTIONS
DESIGNATED AS APPLICABLE TO OTHER TRADES. IN CASE OF CONFLICTS, THE AFFECTED CONTRACTOR IS REQUIRED TO EITHER OBTAIN DIRECTION FROM AN APPROPRIATE REPRESENTATIVE OF THE OWNER, OR OTHERWISE TO APPLY THE MORE STRINGENT
STANDARD. THESE PLANS ARE INTENDED TO SET FORTH THE REQUIREMENTS FOR CONSTRUCTION IN ONLY AN INDUSTRY-STANDARD LEVEL OF QUALITY AND DETAIL, AND THEY ARE INTENDED TO BE SUPPLEMENTED BY APPROPRIATE REQUESTS FOR
CLARIFICATION AND INFORMATION. ERRORS AND OMISSIONS ARE TO BE EXPECTED AND ANTICIPATED, AND ALL CONTRACTORS ARE REQUIRED TO CAREFULLY REVIEW THESE PLANS FOR ERRORS AND OMISSIONS AND TO BRING THESE ERRORS AND OMISSIONS
TO THE ATTENTION OF A APPROPRIATE OWNER & ARCHITECT IN WRITING IN A TIMELY MANNER; AND ANY CONTRACTOR WHO FAILS TO DO SO BEFORE BIDDING OR OTHERWISE PROCEEDING ASSUMES THE RISK OF ANY CONSEQUENCES. SCALED DIMENSIONS
SHOULD BE CONSIDERED ONLY APPROXIMATE; AND IN ANY DIMENSIONS BEFORE PROCEEDING WITH ANY AFFECTED PROCUREMENT, FABRICATION OR CONSTRUCTION. SCHEMATIC PLANS ARE INTENDED ONLY TO DEMONSTRATE THE RELATIONSHIP AMONG
COMPONENT PARTS, AND NOT TO DEPICT SPECIFIC LOCATIONS (E.G. SCHEMATIC ELECTRICAL PLANS).
15. DIMENSIONS ON DRAWINGS: FIGURED DIMENSIONS SHALL BE FOLLOWED IN PREFERENCE TO SCALE, AND DETAIL DRAWINGS IN PREFERENCE TO SMALL SCALE DRAWINGS. SUB-CONTRACTOR AND CONTRACTOR SHALL CHECK ACCURACY OF ALL
DIMENSIONS IN THE FIELD PRIOR TO ANY WORK BEING CONSTRUCTED OR MATERIALS OR PRODUCTS FABRICATED OR ORDERED. SPECIFICATIONS AND WRITTEN NOTES AND SCHEDULES ON DRAWINGS SHALL BE FOLLOWED IN PREFERENCE TO INFORMATION
FURNISHED IN THE FORM OF LINE DRAWINGS. DETAILED DRAWINGS FURNISHED DURING CONSTRUCTION OR APPROVED BY CONTRACTOR OR ARCHITECT ARE TO BE CONSIDERED EXPLANATORY AND NOT AS CHANGES TO DRAWINGS AND SPECIFICATIONS.
NOTES, FIGURES AND DETAILS ON SAID DRAWINGS SHALL BE FOLLOWED AND EXECUTED AS IF PART OF THESE DOCUMENTS. DRAWINGS ARE NOT TO BE SCALED UNLESS PERMITTED BY THE ARCHITECT. DIMENSIONS SHALL GOVERN. ALL EXTERIOR
DIMENSIONS ARE BASED ON NOMINAL SIZES OF MEMBERS AND ARE GIVEN TO THE OUTER FACE OF SUCH MEMBERS, UNLESS OTHERWISE NOTED ON DRAWINGS. INTERIOR PARTITIONS ARE DIMENSIONED FROM FACE OF STRUCTURE TO FACE OF STRUCTURE
UNLESS OTHERWISE NOTED ON DRAWINGS. WHERE DIMENSION IS LABELED "CLEAR" IT IS TAKEN FROM THE FACE OF FINISH TO FACE OF FINISH OF EACH MATERIAL. PLUS OR MINUS (+/-) DIMENSIONS SHALL NOT VARY BY MORE THAN 2" WITHOUT APPROVAL
BY ARCHITECT. WALL ANGLES ARE EITHER 90° OR 45° UNLESS NOTED OTHERWISE.
16. SUBMITTALS, MEETING NOTES, BULLETINS, AND MEMOS: SUBMITTALS WILL BE REVIEWED BY THE ARCHITECT, IF AT ALL, ONLY PURSUANT TO THE INDUSTRY-STANDARD PROTOCOL SET FORTH IN AIA DOCUMENT A201-2017; AND IN NO EVENT WILL THE
SUBMITTAL REVIEW PROCESS RELIEVE OR LESSEN THE SUBMITTING CONTRACTOR'S RESPONSIBILITY FOR AN INAPPROPRIATE SUBMITTAL. ARCHITECT, FROM TIME TO TIME, WILL ISSUE CONSTRUCTION NOTES OR MEMOS REGARDING CONSTRUCTION ISSUES
THAT HAVE ARISEN SINCE THE DRAWINGS AND SPECIFICATIONS WERE COMPLETED. CONTRACTOR SHALL REVIEW THESE WRITTEN DOCUMENTS AND INCORPORATE THEM INTO THE PROJECT. ANY QUESTIONS OR OBJECTIONS AS TO THE INTENT OF THE WRITTEN
DOCUMENT ITEMS WILL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT FOR DISCUSSION AND OR CLARIFICATION. ANY ITEM THAT RESULTS IN A CHANGE TO THE COST OR TIMING OF THE PROJECT SHALL BE BROUGHT TO THE IMMEDIATE
ATTENTION OF THE OWNER & ARCHITECT PRIOR TO EXECUTING. CONTRACTOR SHALL SUBMIT FABRICATION SHOP DRAWINGS TO THE ARCHITECT FOR APPROVAL PRIOR TO ORDERING AND/OR FABRICATION. CONTRACTOR SHALL SUBMIT MANUFACTURER'S CUTS
FOR ALL FIXTURES AND EQUIPMENT CALLED FOR ON THE CONSTRUCTION DOCUMENTS TO ARCHITECT INCLUDING BUT NOT LIMITED TO LIGHT FIXTURES, HARDWARE, PLUMBING FIXTURES, KITCHEN EQUIPMENT, ETC. BY SUBMITTING SHOP DRAWINGS AND
PRODUCT DATA, THE CONTRACTOR REPRESENTS THAT HE/SHE HAS VERIFIED FIELD CONDITIONS, DIMENSIONS AND RELATED CONSTRUCTION AND HAS COORDINATED THE SUBMISSION CONSTRUCTION WITH THE REQUIREMENTS OF ALL OTHER RELATED WORK IN
THE CONSTRUCTION DOCUMENTS. ALL SHOP DRAWINGS AND CUTS MARKED "REVIEWED" BY ARCHITECT, ARE FOR VERIFICATION OF ADHERENCE TO THE DESIGN INTENT ONLY. THE CONTRACTOR SHALL ASSUME RESPONSIBILITY FOR ALL MEANS AND METHODS
AND ERRORS AND OMISSIONS ON THEIR DRAWINGS. CONTRACTOR TO SUBMIT A COMPLETE SHOP DRAWINGS AND OR SUBMITTAL FOR APPROVAL BEFORE COMMENCING FABRICATION AND/OR INSTALLATION OF ALL APPLICABLE ITEMS. ALL SHOP DRAWINGS
DIMENSIONS SHALL BE FIELD VERIFIED, REVIEWED AND APPROVED BY CONTRACTOR BEFORE SUBMITTAL. SHOP DRAWINGS WHICH ARE INCOMPLETE OR LACKING SUFFICIENT INFORMATION WILL BE RETURNED WITHOUT REVIEW. SUBMIT SAMPLES FOR INITIAL
SELECTION PURPOSES OF ACTUAL VENEERS SHOWING A FULL RANGE OR GRAIN VARIATION, FINISH AND PATTERNS PROPOSED. SUBMIT SAMPLES AS REQUIRED UNTIL APPROVED BY ARCHITECT. SAMPLES SHALL BE 12" X 12" MIN., ONE UNIT OF EACH TYPE
AND FINISH.
17. ERRORS AND OMISSIONS: ERRORS OR OMISSIONS WHICH APPEAR ON THE DRAWINGS, IN SPECIFICATIONS OR OTHER CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT BY THE CONTRACTOR AND TO THE
CONTRACTOR BY THE SUB-CONTRACTOR IN WRITING. IN EVENT OF FAILURE OF SUB-CONTRACTOR TO GIVE SUCH WRITTEN NOTIFICATION BEFORE CONSTRUCTION OR FABRICATIONS OF THE WORK, HE WILL BE HELD RESPONSIBLE FOR THE RESULTS OF ANY SUCH
ERRORS OR OMISSIONS AND THE COSTS OF RECTIFYING SAME. HOWEVER, DRAWINGS AND SPECIFICATIONS ARE COMPLEMENTARY AND WORK CALLED FOR ON ONE AND NOT THE OTHER SHALL BE PROVIDED AS THOUGH FULLY SET FORTH IN BOTH.
18. BARRICADES: CONTRACTOR SHALL ERECT AND PROPERLY MAINTAIN AT ALL TIMES AS REQUIRED BY CONDITIONS AND PROGRESS OF THE WORK, ALL NECESSARY PROTECTIVE BARRICADES, FENCES AND OTHER SAFEGUARDS FOR THE PROTECTION OF THE
WORKERS AND THE PUBLIC. THESE BARRICADES SHALL BE CONSTRUCTED AND BE LOCATED AS SHALL BE DETERMINED BY LOCAL AUTHORITIES AND CODES.
19. TEMPORARY BRACING: AT ALL TIMES DURING CONSTRUCTION ACTIVITIES OR ERECTION OF PROJECT OR ITS COMPONENT PARTS, PRIOR TO COMPLETION OF THE STRUCTURAL FRAME OR REPLACEMENT AND PERMANENT CONNECTION OF COMPONENT
MEMBERS TO THE STRUCTURAL FRAME, SUB-CONTRACTORS SHALL PROVIDE, INSTALL AND MAINTAIN PROPERLY DESIGNED AND CONSTRUCTED TEMPORARY BRACING OF ADEQUATE STRENGTH TO PREVENT DISLOCATION, DISTORTION, CRACKING, FALLING OFF,
OR ANY OTHER DAMAGE TO WORK OR ANY OF ITS COMPONENT PARTS DUE TO FORESEEABLE NORMAL AS WELL AS NOT FORESEEABLE EXCESSIVE WIND AND EARTHQUAKE FORCES WITHOUT ADDITIONAL COST TO OWNER. CONTRACTOR AND HIS
SUBCONTRACTORS SHALL, AT THEIR EXPENSE, REPLACE OR REPAIR, AS DIRECTED, DAMAGED PORTIONS OF THEIR WORK OR COMPONENT PARTS.
20. TOXIC SUBSTANCES REMOVAL: PRIOR TO ANY WORK BEING PERFORMED, WHENEVER THERE ARE EXISTING STRUCTURES TO BE REMOVED OR ALTERED, CONTRACTOR SHALL BE RESPONSIBLE FOR THE LOCATION AND REMOVAL OF ANY TOXIC MATERIALS OR
SUBSTANCES AS REQUIRED BY THE STATE OF CALIFORNIA INCLUDING BUT NOT LIMITED TO ASBESTOS, LEAD PAINTS, MOLD, ETC. REMOVAL AND DISPOSAL SHALL FOLLOW STATE MANDATED METHODS, PROCEDURES, DOCUMENTATION AND APPLICATION
REQUIREMENTS.
21. NO CHANGES ARE TO BE MADE ON THESE PLANS WITHOUT THE KNOWLEDGE OR CONSENT OF THE ARCHITECT/ ENGINEER WHOSE SIGNATURE APPEARS HERON.
22. NO FRAMING OF ANY TYPE TO BE CONCEALED PRIOR TO INSPECTION BY GOVERNING AGENCIES.
23. REFERENCES TO ANY DETAIL OR DRAWINGS IS FOR CONVENIENCE ONLY AND DOES NOT LIMIT THE APPLICATION OF SUCH DETAIL OR DRAWINGS.
24. USE 2X6 MINIMUM STUDS FOR PLUMBING WALLS
25. MAINTENANCE INFORMATION: THE BUILDER SHALL PROVIDE TO THE BUILDING OWNER AT OCCUPANCY MAINTENANCE INFORMATION FOR ALL FEATURES, MATERIALS, COMPONENTS, AND MANUFACTURED INFORMATION FOR ALL FEATURES, MATERIALS, AND
COMPONENTS AND MANUFACTURED DEVICES THAT REQUIRE ROUTINE MAINTENANCE FOR EFFICIENT OPERATION. REQUIRED ROUTINE MAINTENANCE ACTIONS SHALL BE CLEARLY STATED AND INCORPORATED ON A READILY ACCESSIBLE LABEL. THE LABEL MAY
BE LIMITED TO IDENTIFYING, BY TITLE AND/OR PUBLICATION NUMBER, THE OPERATION AND MAINTENANCE MANUAL FOR THAT PARTICULAR MODEL AND TYPE OF FEATURE, MATERIAL, COMPONENT, OR MANUFACTURED DEVICE. (SEE CALGREEN NOTES FOR
ADDITIONAL REQUIREMENTS OF OPERATION & MAINTENANCE MANUAL)
26. GENERAL CONTRACTOR, CONTRACTORS, SUB-CONTRACTORS AND BUILDERS TO COORDINATE ALL ENGINEERING AND MECHANICAL DRAWINGS WITH ARCHITECTURAL DRAWINGS BEFORE PROCEEDING WITH WORK. IF DISCREPANCIES ARE APPARENTLY
OBSERVED OR INFORMATION APPARENTLY IS THOUGHT TO BE MISSING, NOTIFY ARCHITECT WITHIN 24 HOURS WITH SKETCH, DRAWING, PDF, PHOTOCOPIES WITH LEGIBLE HANDWRITTEN NOTES AND/OR WRITING (FAX, EMAIL OR CORRESPONDENCE). IF CONFLICT
WITH EXISTING CONDITIONS, PROVIDE DOCUMENTATION (PHOTOS, SKETCHES, DWGS) OF EXISTING CONDITIONS AND SUGGEST PROPOSAL(S) FOR SOLUTION (SKETCH, DRAWING, AND/OR WRITING). IN CASE OF ANY DISCREPANCIES, THE ARCHITECT IS THE SOLE
INTERPRETER OF THE CONTRACT DOCUMENTS.
27. CONTRACTOR SHALL NOTIFY ARCHITECT FOR CLARIFICATION PRIOR TO BIDDING OF ANY DISCREPANCIES BETWEEN ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS. BID SHALL BE BASED ON THE MOST STRINGENT REQUIREMENT.
28. CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT OF ANY UNEXPECTED OR UNKNOWN FIELD CONDITIONS, ERRORS, OMISSIONS, OR DISCREPANCIES IN THE DRAWINGS, PROJECT MANUAL, OR CONTRACT DOCUMENTS PRIOR TO PROCEEDING WITH
THE WORK OR SHOP FABRICATIONS.
29. CONTRACTOR SHALL PREPARE AND MAINTAIN ALL CONSTRUCTION, AND SURROUNDING AREAS, FREE OF DEBRIS OR HAZARDOUS MATERIALS AT ALL TIMES. CONTRACTOR SHALL TAKE NECESSARY PRECAUTIONS TO PREVENT DUST FROM RISING.
30. CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR AND/OR THE REPLACEMENT OF ANY ITEMS DAMAGED DURING CONSTRUCTION OR CLEAN-UP. ANY DAMAGE TO EXISTING STRUCTURES DURING THE CONSTRUCTION OR THE NEW WORK SHALL BE
REPAIRED TO EQUIVALENT OR BETTER THAN ORIGINAL CONDITION AT CONTRACTOR'S EXPENSE.
31. ALL OSHA REGULATIONS FOR CONSTRUCTION AREAS SHALL BE STRICTLY FOLLOWED. CONTRACTOR SHALL PROVIDE PROPER SAFEGUARDS DURING ALL PHASES OF CONSTRUCTION.
32. CONTRACTOR TO REMOVE, RELOCATE OR RE-ROUTE, AS NECESSARY, ELECTRICAL, TELEPHONE, WATER, SEWER, GAS OR ANY OTHER UTILITY LINES ENCOUNTERED AND SHALL COORDINATE THIS WORK WILL ALL LOCAL UTILITY COMPANIES.
33. CONTRACTOR SHALL PROVIDE TEMPORARY WEATHER PROTECTION FOR PORTIONS OF THE WORK THAT BECOME EXPOSED TO WEATHER AND SHALL BE RESPONSIBLE FOR DAMAGE CAUSED BY INSUFFICIENT PROTECTION.
34. CONTRACTOR TO OBTAIN WRITTEN APPROVAL FROM OWNER AND ARCHITECT PRIOR TO ANY CHANGES OR DEVIATION FROM CONTRACT DOCUMENTS.
35. CONTRACTOR SHALL SUBMIT IN WRITING ALL PROPOSALS FOR ADDITIONAL WORK TO THE OWNER FOR REVIEW AND APPROVAL. NO WORK IS TO PROCEED UNTIL AN AUTHORIZATION TO PROCEED; SIGNED BY THE ARCHITECT & OWNER'S REPRESENTATIVE IS
RETURNED TO THE GENERAL CONTRACTOR.
36. CONTRACTOR SHALL BE AWARE THAT SPECIFIC FIRE-RATED SEPARATION WITHIN THE BUILDING'S CONSTRUCTION IS REQUIRED BY CODE. THE USE OF SPECIFIC MATERIALS AND COMBINATION OF MATERIALS WITHIN FIRE RATED ASSEMBLIES, AS CALLED
FOR ON THE DRAWINGS AND SPECIFICATIONS, ARE FOR THE PURPOSE OF ACHIEVING THOSE REQUIRED FIRE SEPARATIONS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THAT ANY CHANGE IN MATERIAL THAT IS REQUESTED BY OR MADE BY THE
CONTRACTOR AND/OR ITS SUBCONTRACTORS, FROM THOSE MATERIALS DRAWN OR SPECIFIED, DOES NOT IN ANY WAY AFFECT OR LESSEN THE REQUIRED CONSTRUCTION ASSEMBLY INTEGRITY. SPECIFIC SEQUENCES OR METHODS OF ACHIEVING FIRE RATED
ASSEMBLIES REQUIRED BY A "U.L. NO." LISTING SHALL BE FOLLOWED WITHOUT DEVIATION, UNLESS OTHERWISE NOTED OR DETAILED.
37. CONTRACTOR TO FURNISH AND INSTALL ALL BLOCKING REQUIRED FOR WALL MOUNTED OR BRACED FIXTURES, MILLWORK, SHELVES, TOILET FIXTURES, AND ACCESSORIES OR 'BY OTHER' ITEMS DESCRIBED IN INTERIOR DESIGN AND ARCHITECTURAL
DRAWINGS. BLOCKING SHALL BE CONSTRUCTED TO SUPPORT THE IMPOSED LOAD.
38. ALL MANUFACTURED ARTICLES, MATERIALS AND EQUIPMENT SHALL BE SUPPLIED, INSTALLED, CONNECTED, ERECTED, USED, CLEANED AND CONDITIONED AS DIRECTED BY THE MANUFACTURERS AND REQUIRED BY CODE.
39. PRIOR TO CONSTRUCTION, CONTRACTOR TO VERIFY/COORDINATE UTILITY REQUIREMENTS FOR ALL OWNER/VENDOR FURNISHED EQUIPMENT, FIXTURES OR APPLIANCES.
40. CONTRACTOR SHALL PROVIDE ALL NECESSARY FASTENERS, SUPPORTS, SHIMMING, FLASH PATCHING, ETC. FOR THE PROPER INSTALLATION OF SUCH ITEMS AS DIRECTED BY THE MANUFACTURERS.
41. UPON COMPLETION OF THE PROJECT, THE CONTRACTOR SHALL GIVE TO THE OWNER A COMPLETE SET OF AS-BUILT CIVIL, LANDSCAPE, ARCHITECTURAL, MECHANICAL, PLUMBING, ELECTRICAL AND FIRE PROTECTION DRAWINGS ALONG WITH THE WRITTEN
GUARANTIES, OPERATION AND MAINTENANCE MANUALS OF ALL EQUIPMENT AND FINISHES INSTALLED. THE CONTRACTOR SHALL MAINTAIN A CURRENT SET OF AS-BUILT DRAWINGS AND SPECIFICATIONS. INFORMATION SHALL BE RECORDED BY CONTRACTOR
AS CONSTRUCTION PROGRESSES AND REVIEWED FOR COMPLETENESS AT EACH REQUISITION REQUEST.
42. CONTRACTOR IS RESPONSIBLE TO THOROUGHLY VACUUM CLEAN ALL CARPETED AREAS, CLEAN ALL FLOORING, MILLWORK, LIGHT FIXTURES, GLASS, ETC. AND UNCOVER AND VACUUM OUT ALL MECHANICAL UNITES AFTER THE WORK IS COMPLETED AND
MAINTAIN CLEAN CONDITIONS THROUGH THE TENANT'S MOVE-IN.
WATERPROOFING AND DAMPPROOFING NOTES:
R406.1 CONCRETE AND MASONRY FOUNDATION DAMPPROOFING
EXCEPT WHERE REQUIRED BY SECTION R406.2 TO BE WATERPROOFED, FOUNDATION WALLS THAT RETAIN EARTH AND
ENCLOSE INTERIOR SPACES AND FLOORS BELOW GRADE SHALL BE DAMPPROOFED FROM THE HIGHER OF (A) THE TOP OF THE
FOOTING OR (B) 6 INCHES (152 MM) BELOW THE TOP OF THE BASEMENT FLOOR, TO THE FINISHED GRADE. MASONRY WALLS
SHALL HAVE NOT LESS THAN 3/8-INCH (9.5 MM) PORTLAND CEMENT PARGING APPLIED TO THE EXTERIOR OF THE WALL. THE
PARGING SHALL BE DAMPPROOFED IN ACCORDANCE WITH ONE OF THE FOLLOWING:
1. BITUMINOUS COATING.
2. THREE POUNDS PER SQUARE YARD (1.63 KG/M2) OF ACRYLIC MODIFIED CEMENT.
3. ONE-EIGHTH-INCH (3.2 MM) COAT OF SURFACE-BONDING CEMENT COMPLYING WITH ASTM C887.
4. ANY MATERIAL PERMITTED FOR WATERPROOFING IN SECTION R406.2.
5. OTHER APPROVED METHODS OR MATERIALS.
EXCEPTION:PARGING OF UNIT MASONRY WALLS IS NOT REQUIRED WHERE A MATERIAL IS APPROVED FOR DIRECT
APPLICATION TO THE MASONRY.CONCRETE WALLS SHALL BE DAMPPROOFED BY APPLYING ANY ONE OF THE LISTED
DAMPPROOFING MATERIALS OR ANY ONE OF THE WATERPROOFING MATERIALS LISTED IN SECTION R406.2 TO THE EXTERIOR
OF THE WALL.
R406.2 CONCRETE AND MASONRY FOUNDATION WATERPROOFING
IN AREAS WHERE A HIGH WATER TABLE OR OTHER SEVERE SOIL-WATER CONDITIONS ARE KNOWN TO EXIST, EXTERIOR
FOUNDATION WALLS THAT RETAIN EARTH AND ENCLOSE INTERIOR SPACES AND FLOORS BELOW GRADE SHALL BE
WATERPROOFED FROM THE HIGHER OF (A) THE TOP OF THE FOOTING OR (B) 6 INCHES (152 MM) BELOW THE TOP OF THE
BASEMENT FLOOR, TO THE FINISHED GRADE. WALLS SHALL BE WATERPROOFED IN ACCORDANCE WITH ONE OF THE
FOLLOWING:
1. TWO-PLY HOT-MOPPED FELTS.
2. FIFTY-FIVE-POUND (25 KG) ROLL ROOFING.
3. SIX-MIL (0.15 MM) POLYVINYL CHLORIDE.
4. SIX-MIL (0.15 MM) POLYETHYLENE.
5. FORTY-MIL (1 MM) POLYMER-MODIFIED ASPHALT.
6. SIXTY-MIL (1.5 MM) FLEXIBLE POLYMER CEMENT.
7. ONE-EIGHTH-INCH (3 MM) CEMENT-BASED, FIBER-REINFORCED, WATERPROOF COATING.
8. SIXTY-MIL (1.5 MM) SOLVENT-FREE LIQUID-APPLIED SYNTHETIC RUBBER.
ALL JOINTS IN MEMBRANE WATERPROOFING SHALL BE LAPPED AND SEALED WITH AN ADHESIVE COMPATIBLE WITH THE
MEMBRANE.
EXCEPTION: ORGANIC-SOLVENT-BASED PRODUCTS SUCH AS HYDROCARBONS, CHLORINATED HYDROCARBONS, KETONES AND
ESTERS SHALL NOT BE USED FOR ICF WALLS WITH EXPANDED POLYSTYRENE FORM MATERIAL. USE OF PLASTIC ROOFING
CEMENTS, ACRYLIC COATINGS, LATEX COATINGS, MORTARS AND PARGINGS TO SEAL ICF WALLS IS PERMITTED. COLD-SETTING
ASPHALT OR HOT ASPHALT SHALL CONFORM TO TYPE C OF ASTM D449. HOT ASPHALT SHALL BE APPLIED AT A TEMPERATURE
OF LESS THAN 200°F (93°C).
DIMENSION NOTE:
ALL DIMENSIONS ARE TO FACE OF SHEATHING (EXT. WALLS) OR FACE OF STRUCTURE (F.O.S.) TYP. U.N.O. ROUNDED TO THE
NEAREST 1/8" AND INTERIOR PARTITIONS ARE DIMENSIONED FROM FACE OF STRUCTURE TO FACE OF STRUCTURE (F.O.S.)
U.N.O. -CONTACT ARCHITECT IN WRITING FOR ANY CLARIFICATION OF NOTED DIMENSIONS, DO NOT SCALE PLANS.
ROUGH FRAMING:
ALL EXTERIOR WALLS TO BE FRAMED W/. 2X6 STUD MIN. U.N.O.
USE 2X6 MINIMUM STUDS FOR PLUMBING WALLS
SECOND AND THIRD FLOOR PLYWOOD TO BE 1-1/8"
ENTIRE EXTERIOR TO BE SHEATHED WITH 1/2" PLYWOOD
DOORS AND WINDOWS WILL TYPICALLY BE RECESSED FROM EXTERIOR WALL PLANE. VERIFY ALL ROUGH OPENING
DIMENSIONS WITH DOOR AND WINDOW MFGR. ROUGH OPENING MAY NEED TO BE OVERSIZED TO ACCOUNT FOR ADDITIONAL
FRAMING. SEE SHT. AD-2.0 FOR TYP. RECESSED CONDITIONS.
DUCTS PENETRATION:
DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE
SHALL BE CONSTRUCTED OF A MINIMUM NO. 26 GAGE (0.48 MM) SHEET STEEL OR OTHER APPROVED MATERIAL AND SHALL
NOT HAVE OPENINGS INTO THE GARAGE (R302.5.2)
STAIRWAY ILLUMINATION:
1.INTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE TO ILLUMINATE THE LANDINGS AND TREADS.
THE LIGHT SOURCE SHALL BE CAPABLE OF ILLUMINATING TREADS AND LANDINGS TO LEVELS OF NOT LESS THAN 1 FOOT-
CANDLE (11 LUX) AS MEASURED AT THE CENTER OF TREADS AND LANDINGS. THERE SHALL BE A WALL SWITCH AT EACH
FLOOR LEVEL TO CONTROL THE LIGHT SOURCE WHERE THE STAIRWAY HAS SIX OR MORE RISERS. (R303.7)
EXCEPTION:A SWITCH IS NOT REQUIRED WHERE REMOTE, CENTRAL OR AUTOMATIC CONTROL OF LIGHTING IS
PROVIDED.
2.EXTERIOR STAIRWAYS SHALL BE PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE LOCATED AT THE TOP LANDING OF THE
STAIRWAY. EXTERIOR STAIRWAYS PROVIDING ACCESS TO A BASEMENT FROM THE OUTDOOR GRADE LEVEL SHALL BE
PROVIDED WITH AN ARTIFICIAL LIGHT SOURCE LOCATED AT THE BOTTOM LANDING OF THE STAIRWAY. (R303.8)
GARAGE FLOOR:
GARAGE FLOOR SURFACES SHALL BE OF APPROVED NONCOMBUSTIBLE MATERIAL.THE AREA OF FLOOR USED FOR PARKING OF
AUTOMOBILES OR OTHER VEHICLES SHALL BE SLOPED TO FACILITATE THE MOVEMENT OF LIQUIDS TO A DRAIN OR TOWARD
THE MAIN VEHICLE ENTRY DOORWAY. (R309.1)
PLUMBING:
1. ALL FIXTURES AND FITTINGS SHALL COMPLY WITH THE MAX FLOW RATE SET BY CALGREEN (CALIFORNIA GREEN BUILDING
STANDARD CODE) AND CALIFORNIA PLUMBING CODES. G.C. TO VERIFY PRIOR TO PURCHASE AND INSTALL OF ANY FIXTURE
AND FITTING
2. MAX. TEMP. OF 120° TO BE APPROVED BY THE USE OF PRESSURE BALANCE OR THERMOSTATIC MIXING VALVES TYP. IN
COMPLIANCE W/. ASSE 1070/ASME A112.1070/CSA B125.70 @ SHOWERS & TUBS.
3. MAX. TEMP. OF 110° TO BE APPROVED BY THE USE OF PRESSURE BALANCE OR THERMOSTATIC MIXING VALVES TYP. IN
COMPLIANCE W/. ASSE 1070/ASME A112.1070/CSA B125.70 @ BIDETS.
4. SUPPORT ALL WALL-HUNG FIXTURES WITH METAL SUPPORTING MEMBERS TO PREVENT ANY STRAIN TRANSMISSION TO
THE CONNECTIONS. FRAMING AFFIXED SUPPORTS FOR OFF-THE-FLOOR WATER CLOSETS WITH CONCEALED TANKS SHALL
COMPLY WITH ASME A112.6.2. SECURE FLUSH TANK AND SIMILAR APPURTENANCES WITH APPROVED NON-CORROSIVE SCREW
OR BOLTS. (CPC 402.5)
5. THE NET AREA OF THE SHOWER ENCLOSURE SHALL BE 1,024 SQ. INCHES (7.1 SQ. FT.) OR MORE IN THE CLEAR FLOOR AREA,
AND SHALL ALSO BE CAPABLE OF ENCOMPASSING A 30-INCH DIAMETER CIRCLE. (CPC 408.6)
6. THE WATER HEATER BURNER AND BURNER-IGNITION DEVICE TO BE AT LEAST 18-INCHES ABOVE THE FLOOR, IF LOCATED IN A
GARAGE AND IN ADJACENT SPACES THAT OPEN TO THE GARAGE. FOR WATER HEATER IN THE GARAGE OR OTHER AREAS
SUBJECT TO MECHANICAL DAMAGE PROVIDE A PROTECTIVE BARRIER OR ELEVATE THE APPLIANCE TO BE OUT OF THE NORMAL
PATH OF THE VEHICLE. (CPC 507.13)
7. ANCHOR OR STRAP THE WATER HEATER(S) TO RESIST HORIZ. DISPLACEMENT DUE TO THE EARTHQUAKE. STRAPPING
SHOULD BE AT THE UPPER AND LOWER ONE THIRD (1/3) POINTS OF THE APPLIANCE HEIGHT. MAINTAIN A MIN. 4-INCHES
ABOVE THE CONTROLS WITH STRAPPING AT LOWER POINT.
MATERIALS & FINISHES:
1. WALLS COVERINGS AND FLOOR OF SHOWERS AND BATHTUBS WITH A SHOWER HEAD SHALL BE OF CEMENT PLASTER, TILE,
OR APPROVED EQUAL NONABSORBENT SURFACE, TO A HEIGHT OF NOT LESS THAN 72-INCHES ABOVE THE FLOOR. PROVIDE
CEMENT BOARD, CEMENT PLASTER BACKING, OR TILE BACKBOARD FOR TILE FINISH. (CRC R307.2)
2. INSTALL MIN. 5/8" TYPE 'X' MOISTURE & MOLD RESISTANT GYPSUM WALL BOARD IN ALL BATHROOMS AND KITCHENS.
FIREPLACES:
1. FACTORY-BUILT FIREPLACES, CHIMNEYS AND ALL OF THEIR COMPONENTS SHALL BE LISTED AND INSTALLED IN
ACCORDANCE WITH THEIR LISTING AND MANUFACTURER'S INSTALLATION INSTRUCTIONS. (CRC R1004.1)
2. FACTORY BUILT WOOD BURNING FIREPLACES SHALL BE QUALIFIED AT THE U.S. EPA’S VOLUNTARY FIREPLACE PROGRAM
PHASE 2 EMISSIONS LEVEL. (CRC 1004.1.1)
3. DECORATIVE SHROUDS SHALL NOT BE INSTALLED AT THE TERMINATION OF FACTORY-BUILT CHIMNEYS EXCEPT WHERE
SUCH SHROUDS ARE LISTED AND LABELED FOR USE WITH THE SPECIFIC FACTORY-BUILT CHIMNEY SYSTEM AND ARE
INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS. (CRC R1005.2 & CMC 802.5.1.1 & CMC
802.5.4.3)
4. HORIZONTAL OPENINGS ARE NOT ALLOWED, FOR EXHAUST VENTS, IN WALLS CLOSER THAN 3 FEET TO A PROPERTY LINE.
(TABLES R302.1(1)&(2)). HORIZONTAL VENT CAPS SHALL BE 2 FEET CLEAR FROM PROPERTY LINES.
5. EXHAUST OPENINGS SHALL NOT BE DIRECTED ONTO WALKWAYS. (R303.5.2)
6. SOLID FUEL BURNING FIREPLACES (IF PERMISSIBLE):
A. PROVIDE A PERMANENTLY ANCHORED GASEOUS FUEL BURNING PAN TO THE FIREBOX OF A SOLID
FUEL BURNING FIREPLACE.
B. SOLID FUEL BURNING FIREPLACE MUST COMPLY WITH THE CALIFORNIA ENERGY STANDARDS MANDATORY MEASURES.
C. CHIMNEY SHALL EXTEND AT LEAST 2 FT. HIGHER THAN ANY PORTION OF THE BUILDING WITHIN 10 FT., BUT SHALL
NOT BE LESS THAN 3 FT. ABOVE THE HIGHEST POINT WHERE THE CHIMNEY PASSES THROUGH THE ROOF. (CRC R1003.9)
D. LIQUID FUELED FIREPLACES ARE NOT ALLOWED FOR INTERIOR USE.
7. ANY INSTALLED GAS FIREPLACE SHALL BE DIRECT VENT SEALED-COMBUSTION PER CAL GREEN SECTION 4.503.
POOL:
1. PROVIDE AN ALARM FOR DOORS AND WINDOWS WITH SILL HEIGHTS LESS THAN 60-INCHES ABV.F.F. OF THE DWELLING THAT
FORMS A PART OF THE POOL ENCLOSURE. THE ALARM SHALL BE LISTED AS A WATER HAZARD ENTRANCE ALARM IN
ACCORDANCE WITH UL 2017. THE DEACTIVATION SWITCH SHALL BE AT LEAST 60" ABOVE THE FLOOR IF THE RESIDENCE IS NOT
REQUIRED TO BE ACCESSIBLE. (CBC 3109 & ISPSC 305.4)
2. SUCTION OUTLETS SHALL BE DESIGNED AND INSTALLED WITH SUCTION ANTIENTRAPMENT GRATE IN ACCORDANCE WITH
ANSI/APSP-16 PER CBC 3109 SECTION (B) OF 115928. SUCTION ENTRAPMENT AVOIDANCE FOR POOL AND SPA SHALL BE
PROVIDED IN ACCORDANCE WITH APSP-7 PER ISPSC SECTION 310.
3. PROVIDE POWER SAFETY COVER IN COMPLIANCE WITH ASTM F1346-91 FOR POOL & SPA (CBC 3109 SECTION (3) OF 115922
& ISPSC 305).
4. POOL ENCLOSURE FENCE SHALL BE 60-INCHES MIN. ABV. FS/NG MEASURED ON THE SIDE THAT FACES AWAY FROM
SWIMMING POOL W/. MAX VERTICAL CLEARANCE OF 2-INCHES BETWEEN FS/NG AND BOTTOM OF THE FENCE/BARRIER
MEASURED ON THE SIDE OF FENCE THAT FACES AWAY FROM SWIMMING POOL. OPENING, GAP, AND VOID IN ENCLOSURE
FENCE OR GATE SHALL NOT ALLOW THE PASSAGE OF 4-INCHES DIAMETER SPHERE OR LARGER. OUTSIDE SURFACE (FACING
AWAY FROM SWIMMING POOL) OF THE POOL ENCLOSURE INCLUDING THE GATE TO BE FREE OF PROTRUSIONS, CAVITIES, OR
OTHER PHYSICAL CHARACTERISTICS THAT WOULD SERVE AS HANDHOLDS OR FOOTHOLDS WHICH COULD ENABLE A CHILD FIVE
YEARS OLD OR YOUNGER TO CLIMB OVER. (CBC 3109 & ISPSC 305)
WOOD OR WOODBASED PRODUCTS NOTE:
WOOD OR WOODBASE PRODUCT SHALL BE OF A NATURAL DURABLE OR PRESERVATIVE-TREADED WOOD IN ACCORDANCE WITH
AWPA U1 FOR THE SPECIES, PRODUCT, PRESERVATIVE AND END USE IN THE FOLLOWING LOCATIONS:
1. WOOD JOISTS OR THE BOTTOM OF A WOOD STRUCTURAL FLOOR WHEN CLOSER THAN 18 INCHES (457 MM) OR WOOD
GIRDERS WHEN CLOSER THAN 12 INCHES (305 MM) TO THE EXPOSED GROUND IN CRAWL SPACES OR UNEXCAVATED AREA
LOCATED WITHIN THE PERIPHERY OF THE BUILDING FOUNDATION.
2. WOOD FRAMING MEMBERS THAT REST ON CONCRETE OR MASONRY EXTERIOR FOUNDATION WALLS AND ARE LESS THAN 8
INCHES (203 MM) FROM THE EXPOSED GROUND.
3. SILLS AND SLEEPERS ON A CONCRETE OR MASONRY SLAB THAT IS IN DIRECT CONTACT WITH THE GROUND UNLESS
SEPARATED FROM SUCH SLAB BY AN IMPERVIOUS MOISTURE BARRIER.
4. THE ENDS OF WOOD GIRDERS ENTERING EXTERIOR MASONRY OR CONCRETE WALLS HAVING CLEARANCES OF LESS THAN
1/2 INCH (12.7 MM) ON TOPS, SIDES AND ENDS.
5. WOOD SIDING, SHEATHING AND WALL FRAMING ON THE EXTERIOR OF A BUILDING HAVING A CLEARANCE OF LESS THAN 6
INCHES (152 MM) FROM THE GROUND OR LESS THAN 2 INCHES (51 MM) MEASURED VERTICALLY FROM CONCRETE STEPS,
PORCH SLABS, PATIO SLABS AND SIMILAR HORIZONTAL SURFACES EXPOSED TO THE WEATHER.
6. WOOD STRUCTURAL MEMBERS SUPPORTING MOISTURE-PERMEABLE FLOORS OR ROOFS THAT ARE EXPOSED TO THE
WEATHER, SUCH AS CONCRETE OR MASONRY SLABS, UNLESS SEPARATED FROM SUCH FLOORS OR ROOFS BY AN IMPERVIOUS
MOISTURE BARRIER.
7. WOOD FURRING STRIPS OR OTHER WOOD FRAMING MEMBERS ATTACHED DIRECTLY TO THE INTERIOR OF EXTERIOR
MASONRY WALLS OR CONCRETE WALLS BELOW GRADE EXCEPT WHERE AN APPROVED VAPOR RETARDER IS APPLIED BETWEEN
THE WALL AND THE FURRING STRIPS OR FRAMING MEMBERS.
WASHER & DRYER NOTE:
AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –PROVIDE POWER , GAS, WATER SUPPLY & DRAINAGE AS REQUIRED -THE
CLOTHES DRYERS VENT SHALL BE OF A RIGID METALLIC MATERIAL AND HAVE A BACKDRAFT DAMPER (CMC 504.4) AND SHALL
NOT EXCEED 14-FEET IN OVERALL LENGTH WITH MAX. OF TWO (2) 90-DEGREE ELBOW, SUBTRACT 2-FEET FOR EACH
ADDITIONAL 90-DEGREE ELBOW. (CMC 504.4.2.1) DRYER VENT TERMINATION MUST BE 3-FEET FROM OPENINGS INTO THE
BUILDING (DOORS AND OPERABLE WINDOWS), 10-FEET FROM FORCED AIR INLET, AND 3-FEET FROM PROPERTY LINE (NOT TO
DISCHARGE ONTO A PUBLIC WALKWAY). (CMC 502.2.1) IF DRYER LOCATED IN A CLOSET PROVIDE A MIN. 100 SQ.IN. OPENING
IN THE CLOSET DOOR. (CMC. 504.4.1)
*HERS VERIFICATION REQUIRED-REFERENCE T-24.1
&AND
.ANGLE
@ AT
C.L. CENTERLINE
∅DIAMETER, ROUND
.PERPENDICULAR
# POUND OR NUMBER
A.B.ANCHOR BOLT
ABV. ABOVE
A/C.AIR CONDITIONING
A.C.ASPHALT CONCRETE
ACOUS ACOUSTICAL
A.D.AREA DRAIN
ADH. ADHESIVE
ADJ. ADJUSTABLE, ADJACENT
AL.ALUMINUM
ALT.ALTERNATE
ANOD.ANODIZED
A.P.ACCESS PANEL
APPX. APPROXIMATE
APPV'D. APPROVED
ARCH.ARCHITECTURAL,ARCHITECT
ASB. ASBESTOS
ASSY. ASSEMBLY
AUTO.AUTOMATIC
B. BATHROOM
BD. BOARD
BEL. BELOW
BET. BETWEEN
BIT. BITUMINOUS
BLDG.BUILDING
BLK. BLOCK
BLK'G.BLOCKING
BM. BEAM
B.O.BY OWNER, BY OTHERS
BOT. BOTTOM
BR. BEDROOM
B.W. BACK OF WALL, BOTTOM OF WALL
CAB. CABINET
C.B.CATCH BASIN
C.B.C. CALIFORNIA BUILDING CODE
C.R.C. CALIFORNIA RESIDENTIAL CODE
CEM.CEMENT
C.G.CORNER GUARD
CHAN.CHANNEL
CHG.CHANGE
C.I. CAST IRON
C.J. CONTROL / CONSTRUCT./CEILING JOINT
CLG. CEILING
CLKG. CAULKING
CLR. CLEAR, CLEARANCE
CNTR.COUNTER
CONC.CONCRETE
COND.CONDITION
CONST. CONSTRUCT, CONSTRUCTION
CORR.CORRIDOR, CORROSIVE
CTSK. COUNTER SINK, COUNTERSUNK
CTR. CENTER
DBL. DOUBLE
DECO.DECORATIVE
DEPT. DEPARTMENT
DET. DETAIL
D.F.DRINKING FOUNTAIN, DOUGLAS FIR
DIA.DIAMETER
DIAG. DIAGONAL
DIM. DIMENSION
DN. DOWN
DR. DOOR
D.S.DOWNSPOUT
D.S.P. DRY STANDPIPE
DWG. DRAWING(S)
E. EXISTING, EAST, ENTRY, EACH
E.J. EXPANSION JOINT
ELEC. ELECTRIC, ELECTRICAL
ELEV. ELEVATOR
EMER.EMERGENCY
ENCL. ENCLOSED, ENCLOSURE
E.P.ELECTRICAL PANEL, END POINT
EQ. EQUAL
EQV. EQUIVALENT
EQUIP.EQUIPMENT
E.W. EACH WAY
EXH. EXHAUST
EXPO.EXPOSED
EXT. EXTERIOR
E.G.EXISTING GRADE
F.FIXED
F.A. FIRE ALARM
FAC. FACTORY
F.C.O. FLOOR CLEAN OUT
F.D.FLOOR DRAIN
FDN. FOUNDATION
F.E. FIRE EXTINGUISHER
F.E.C. FIRE EXTINGUISHER CABINET
F.G.FINISH GRADE
FIXT.FIXTURE
F.J. FLOOR JOIST
F.L. FLOW LINE
FLASH. FLASHING
FLR. FLOOR
FLUOR. FLUORESCENT
F.O.C. FACE OF CONCRETE/CURB
F.O.F. FACE OF FINISH
F.O.S. FACE OF STUD / STRUCTURE / SHEATHING
F.O.M.FACE OF MASONRY
FP. FIREPLACE
F.S. FLOOR SINK, FINISH SURFACE
FT.FOOT, FEET
FTG. FOOTING
FURR.FURRING
FUT. FUTURE
F.V. FIELD VERIFY
GA. GAUGE
GALV. GALVANIZED
G.B.GRAB BAR, GRADE BEAM
G.C.GENERAL CONTRACTOR
GEN.GENERAL
G.F.I.GROUND FAULT INTERRUPT
G.I. GALVANIZED IRON
G.L.B. GLU-LAM BEAM
GND.GROUND
GR. GRADE
GYP. GYPSUM
G.P.GRADE PLANE
H./HT. HIGH, HEIGHT
H.B.HOSE BIBB
H.C.HOLLOW CORE
HD. HARD, HEAD
HDR.HEADER
HDWD.HARDWOOD
HDWR.HARDWARE
H.M. HOLLOW METAL
HORIZ. HORIZONTAL
HR. HOUR
HVAC HEATING VENTILATING AIR CONDITIONING
I.D. INTERIOR DESIGNER, INSIDE DIAMETER/DIMENSION
IN.INCH
INSUL.INSULATION
INT.INTERIOR
INV.INVERT/INVERTED
JAN. JANITOR
JT.JOINT
JST.JOIST
KIT. KITCHEN
L.LOW, LINEN
L.A. LANDSCAPED AREA
LAB. LABORATORY
LAM. LAMINATED
LAV. LAVATORY
LBS. POUNDS
LFA.LOAD FROM ABOVE
L.H. LEFT HAND
LKR. LOCKER
LT.LIGHT
LUM. LUMINOUS, LUMENS
MAINT. MAINTENANCE
MAS.MASONRY
MAT. MATERIAL
MAX.MAXIMUM
M.B.METAL BOLT
M.C. MEDICINE CABINET
MECH.MECHANICAL
MEMB.MEMBRANE
MTL. METAL
MFGR.MANUFACTURER
M.H. MANHOLE
MIN. MINIMUM
MIR. MIRROR
MISC. MISCELLANEOUS
M.O. MASONRY OPENING
MT. MOUNTED
MUL. MULLION
N. NEW, NORTH
NAT. NATURAL
N.I.C.NOT IN CONTRACT, CONTACT
N.G.NATURAL GRADE
NO. NUMBER
NOM.NOMINAL
N.T.S. NOT TO SCALE
O/.OVER
O.A.OVERALL
OBS. OBSCURE
O.C.ON CENTER
O.D.OUTSIDE DIAMETER, DIMENSION
O.F.D. OVERFLOW DRAIN
OFF. OFFICE
OPNG.OPENING
OPP. OPPOSITE
PERIM. PERIMETER
PL.PROPERTY LINE, PLATE
P.LAM. PLASTIC LAMINATE
PLAS. PLASTER
PLUMB. PLUMBING
PLYWD. PLYWOOD
PNT. PAINT(ED)
P.O.C. POINT OF CONTACT, CONNECTION
PR. PAIR
PROJ. PROJECTION
PSL. PARALLEL STRAND LAMINATE
PT. POINT
R.A.RETURN AIR
RAD. RADIUS
R.D.ROOF DRAIN
R.D.L. ROOF DRAIN LEADER
RECPT. RECEPTACLE
RECT. RECTANGLE, RECTANGULAR
REF. REFERENCE
REFR.REFRIGERATOR
REG.REGULAR, REGISTER
REINF. REINFORCE(D), REINFORCEMENT
REQ'D. REQUIRED
RESIL.RESILIENT
RET. RETAIN(ING), RETURN
RM. ROOM
R.O.ROUGH OPENING
R.R.ROOF RAFTER
RWD. REDWOOD
S. SOUTH
S.A.SUPPLY AIR
S.C.SOLID CORE
S.C.D. SEAT COVER DISPENSER
SCHED. SCHEDULE
S.D.SUBDRAIN, SOAP DISPENSER
SEC. SECTION
SEL. SELECT(ED)
SH. SHELF
SHT. SHEET
SHT'G.SHEATHING
SIM.SIMILAR
SIMP. SIMPSON
S.J. SOFFIT JOIST
S.S.STAINLESS STEEL
S.SK.SERVICE SINK
STA. STATION
STD. STANDARD
STL.STEEL
STOR.STORAGE
STRUCT. STRUCTURE, STRUCTURAL
SUSP. SUSPEND(ED)
SYM.SYMMETRICAL
SYS. SYSTEM
T.TREAD, TRASH
T.C.TOP OF CURB
T.CL. TIME CLOCK
TEL.TELEPHONE
TEMP.TEMPERED
TER. TERRAZZO
T & G TONGUE & GROOVE
THK. THICK, THICKNESS
T.P. TOP OF PAVING
T.PL. TOP OF PLATE
T.O.S. TOP OF STRUCTURE, SHEATHING, SLAB
TRANS. TRANSFORMER
T.S. TOP OF STEP
T.W.TOP OF WALL
TYP. TYPICAL
U. UNDER
U.B.C. UNIFORMBUILDING CODE
U.G.UNDERGROUND
U.L. UNDERWRITER'S LABORATORY
UNF. UNFINISHED
U.N.O.UNLESS NOTED OTHERWISE
UR. URINAL
V./VERT. VERTICAL
VENT. VENTILATION, VENTILATING
VER. VERIFY
V.T.R. VENT THROUGH ROOF
W. WEST, WIDTH, WASHER
W/.WITH
WD.WOOD
W.H. WATER HEATER
W.C.WATER CLOSET
W.I. WROUGHT IRON
WP.WATERPROOF(ING)
W.W.M. WELDED WIRE MESH
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
BRANDON ARCHITECTS
CONTRACT DOCUMENT NOTESAGENERAL NOTESBABBREVIATIONSC
01/20/2023
ARCHITECTURAL
GENERAL NOTES
MI
L
L
E
R
R
E
S
I
D
E
N
C
E
MR. & MRS. MATTHEW MILLER
22 BAY ISLAND,
NEWPORT BEACH, CA 92661
P: 949.235.9286
millermg123@gmail.com
CDP
22 BAY ISLAND
NEWPORT BEACH, CA 92661
T-1.1
TBD
BRIAN JOWETT
NO. REVISION DATE
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
BRANDON ARCHITECTS
01/20/2023
SUPPLEMENTAL
DOC. & NOTES
MI
L
L
E
R
R
E
S
I
D
E
N
C
E
MR. & MRS. MATTHEW MILLER
22 BAY ISLAND,
NEWPORT BEACH, CA 92661
P: 949.235.9286
millermg123@gmail.com
CDP
22 BAY ISLAND
NEWPORT BEACH, CA 92661
T-1.2
TBD
BRIAN JOWETT
NO. REVISION DATE
HOUSING CRISIS ACT COMPLIANCE FOR DEMOLITIONS FORM 2
RESIDENTIAL CONSTRUCTION MINIMUM REQUIREMENTS 1
3 CAL GREEN -RESIDENTIAL MANDATORY MEASURES
L1
L2
L3
BAY ISLAND
PORTION OF LOT 5,
SECTION 34
NEWPORT BEACH,
CALIFORNIA
PARCEL 22
PARCEL 1
PARCEL 2
CL BAYISLAND
N6
1
°
3
9
'
2
3
"
W
5
6
.
3
0
'
N28°16'42"E 89.03'
N36°11'09"E 94.8
5
'
BENCHMARK INFORMATION
22
B
A
Y
I
S
L
A
N
D
NE
W
P
O
R
T
B
E
A
C
H
,
C
A
9
2
6
6
1
TO
P
O
G
R
A
P
H
I
C
M
A
P
1 1
TITLE REPORT/EASEMENT NOTES
22 BAY ISLAND
NEWPORT BEACH, CA 92661
NO TITLE REPORT PROVIDED
LEGAL DESCRIPTION
REAL PROPERTY SITUATED IN THE CITY OF NEWPORT BEACH,
COUNTY OF ORANGE, STATE OF CALIFORNIA AND IS
DESCRIBED AS FOLLOWS:
PARCEL 22, BAY ISLAND, PORTION OF LOT 5, SECTION 34
NEWPORT BEACH, CALIFORNIA.
LC
EXISTING ELEVATION
LEGEND
( )
FS FINISHED SURFACE CONCRETE SURFACE
T.B.M.TEMPORARY BENCHMARK
SET ON A SEWER MANHOLE RIM (SMH)
ELEVATION = 13.35 FEET
HU
N
T
I
N
G
T
O
N
B
E
A
C
H
,
C
A
L
I
F
O
R
N
I
A
9
2
6
4
6
PH
O
N
E
:
(
7
1
4
)
4
8
8
-
5
0
0
6
F
A
X
:
(
7
1
4
)
3
3
3
-
4
4
4
0
A
P
E
X
L
S
I
N
C
@
G
M
A
I
L
.
C
O
M
PAUL D. CRAFT, P.L.S. 8516 DATE
NOTE: SECTION 8770.6 OF THE CALIFORNIA BUSINESS AND PROFESSIONS CODE
STATES THAT THE USE OF THE WORD CERTIFY OR CERTIFICATION BY A
LICENSED LAND SURVEYOR IN THE PRACTICE OF LAND SURVEYING OR THE
PREPARATION OF MAPS, PLATS, REPORTS, DESCRIPTIONS OR OTHER SURVEYING
DOCUMENTS ONLY CONSTITUTES AN EXPRESSION OF PROFESSIONAL OPINION
REGARDING THOSE FACTS OR FINDINGS WHICH ARE THE SUBJECT OF THE
CERTIFICATION AND DOES NOT CONSTITUTE A WARRANTY OR GUARANTEE,
EITHER EXPRESSED OR IMPLIED.
LICENSE RENEWAL DATE 12/31/24
S
TATEOF CALI F O R NIA
PAUL
D O M INICK
C
R
A
FT
Exp. 12/31/24
No. 8516PROFESSIONALLAND
S
U
R
V
EYOR
FF FINISHED FLOOR
GAS METERGM
CENTERLINE
TC TOP OF CURB CURB
GRAPHIC SCALE
SURVEYOR OR ENGINEER SHALL PERMANENTLY MONUMENT PROPERTY
CORNERS OR OFFSETS BEFORE STARTING GRADING.
PLEASE CALL PAUL CRAFT @ 714-488-5006 TO SCHEDULE.
SURVEYOR'S NOTES
BLOCK WALL
BRICK SURFACE
NG NATURAL GROUND
BENCHMARK NO: 1E-116-99
DESCRIBED BY OCS 2002 - FOUND 3 3/4" OCS
ALUMINUM BENCHMARK DISK STAMPED "1E-116-99",
SET IN THE NORTHWEST CORNER OF A 5.0 FT.
BY 5.0 FT. CONCRETE CATCH BASIN. MONUMENT IS
LOCATED ALONG THE WESTERLY SIDE OF PALM
STREET, 110 FT. NORTHERLY OF THE CENTERLINE
OF BAY AVENUE AND 21 FT. WEST OF THE
CENTERLINE OF PALM STREET. MONUMENT IS SET
LEVEL WITH THE SIDEWALK.
ELEVATION: 7.587 FEET (NAVD88), YEAR LEVELED 2015
VICINITY MAP
BFP BACK FLOW PREVENTOR
IRRIGATION CONTROL VALVEICV
SMH SEWER MANHOLE
TW TOP OF WALL
TE TRASH ENCLOSURE
TC TOP OF CURB CURB
GAS VALVEGV
WIF WROUGHT IRON FENCE
BASIS OF BEARINGS
THE BASIS OF BEARINGS SHOWN HEREON ARE BASED ON THE CENTERLINE
OF ISLAND AVENUE HAVING A BEARING OF N16°32'02"E PER RSB 183/456-46.
LINE DATA
LINE BEARING DISTANCE
L1 N61°44'51"W 38.67'
L2 N28°18'11"E 5.00'
L3 N61°39'38"W 4.59'
- FOUND EXISTING LEAD, TACK & TAG STAMPED LS2350
MONUMENT NOTES
- FOUND EXISTING LEAD, TACK & TAG STAMPED LS3109
SEARCHED, FOUND NOTHING, SET NOTHING
FOUND EXISTING MONUMENT AS NOTED HEREON
GRASS SURFACE
1/6/2023
DN
DN
UP
DN
DN
1
2 2
5'
BAY
ISLAND
L1
L2
L3
PARCEL 1
PARCEL 2
N28°16'42"E 89.03'
N36°11'09"E 94.85'
(12.28)
FS
(11.69)
FS
(11.76)
FS
(10.59)
FS
(10.46)
FS
(10.52)
FS
(10.28)
FS(9.95)
FS
(9.17)
FS
(8.46)
FS
(7.88)
FS
(7.34)
FS
(7.38)
FS
(6.51)
FS
(6.46)
FS
(6.51)
FS
(6.36)
FS
(6.48)
FS
(6.57)
FS
(6.51)
FS
(6.96)
FS(6.92)
FS
(6.85)
FS
(6.72)
FS
(7.02)
FS
(7.41)
NG
(7.23)
NG
(7.22)
NG
(6.73)
FS
(7.53)
NG
(10.22)TW
(9.70)FS
(10.59)
FS
(7.56)
NG
(10.48)
FS
(10.70)
FS (11.22)
FS
(12.04)
FS (12.26)
FS
(12.51)
FS
(37.28)
RIDGE
(7.53)
NG
(6.69)
FS
(6.71)
FS
(7.17)
FS
(7.08)
FS
(8.02)
FS
(9.44)
FS
(10.47)
FS
(10.86)
FS
(11.42)
FS
(12.34)
FS (13.12)
FS
(13.31)
FS
(13.19)
FS
(12.67)
FS
(13.46)
FS
(11.98)
NG
(13.96)TC
(13.43)FS
(13.93)TC
(13.36)FS
(13.92)TC
(13.21)FS
(13.94)TC
(13.17)FS
(13.17)TC
(13.06)FS
(13.01)TC
(12.46)FS
(13.08)TC
(12.70)FS
(13.12)TC
(12.68)FS
(13.69)TC
(13.23)FS
(13.71)TC
(13.36)FS
(6.74)
NG
(9.41)
NG
(10.45)
NG
(13.54)
SMH RIM
(14.44)
FF
(14.72)
FF
(8.65)FS
(6.68)FS
(9.39)TW
(8.86)FS
18"
TREE
EXISTING
BUILDING
METAL
RING
ICV
ICV
ICV
ICV
ICV
ICV
ICVGVBFP
WOOD
STAIRS
CURB
CURB
CURB
TE
24"
PALM
WIF
WIF
PROPERTY
LINE
PROPERTY
LINE
PROPERTY
LINE
PROPERTY
LINE
PROPERTY
LINE
CL
UP
ROOM TAGROOM NAME
?
1
10.00'SPOT ELEVATION
KEYNOTE TAG
REVISION TAG
PROPERTY LINE TAG90 00' 00"20.00'N E
FIREPIT -AS SELECTED TO BE LISTED AND APPROVED, VERIFY W/.
OWNER –PROVIDE POWER AND GAS AS REQUIRED –INSTALL AND
MAINTAIN CLEARANCES PER MFGR. AND SECTION 308 OF CFC
RECESSED MAIN SERVICE PANEL -400 AMP MAX. (MAINTAIN 36" CLEAR FROM FACE
OF PANEL TO ANY OBSTRUCTION) –GC TO COORDINATE W/. UTILITY COMPANY
A/C CONDENSER / HEAT PUMP -TO BE IN COMPLIANCE OF SECTION 307.3 OF CPC AS
SELECTED, VERIFY W/. OWNER -SIZE TBD, SEE T-24 ENERGY REPORT FOR MORE INFO –
PROVIDE POWER AND SOUND DAMPENING PAD AS REQ’D. –INSTALL AND MAINTAIN
REQUIRED CLEARANCES PER MFGR. INSTRUCTION
VERTICAL STORM DRAIN PIPE IN-WALL / OVERFLOW -MTL. PIPE PER
CHAPTER 11 OF CPC, SIZE PER TABLE 1103.1 (MIN. 2”DIA. PIPE & TYP. 3”DIA. PIPE) –
SEE CIVIL DWGS. FOR TERMINATION DTLS. ABV. OR BLW. GROUND. VERIFY ALL
TERMINATION POINTS, TYPE AND DETAILS W/. CIVIL PRIOR TO POURING THE CONCRETE
SLAB
OVERFLOW
DRAINLINE
UP
EXT. STAIRS -MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE ARTIFICIAL LIGHT
SOURCE AT THE TOP LANDING AND FOR STAIR TO THE BASEMENT AT BOTH TOP
AND BOTTOM LANDING (R303.8) -REF. DTL. 3/AD-1 -VERIFY TREADS DEPTH AND
RISERS HT. W/. CIVIL AND LANDSCAPE DWGS
DIMENSION NOTE:
ALL DIMENSIONS ARE TO FACE OF SHEATHING (EXT. WALLS) OR FACE OF STRUCTURE (F.O.S.) TYP. U.N.O. ROUNDED TO THE
NEAREST 1/8" AND INTERIOR PARTITIONS ARE DIMENSIONED FROM FACE OF STRUCTURE TO FACE OF STRUCTURE (F.O.S.)
U.N.O. -CONTACT ARCHITECT IN WRITING FOR ANY CLARIFICATION OF NOTED DIMENSIONS, DO NOT SCALE PLANS.
GENERAL NOTE:
SEE SHEET A-3.0 FOR ROOF PLAN INFORMATION NOT SHOWN ON THIS SHEET (INCLUDING EAVE DETAILS AND PROJECTION
DISTANCES).
C.N.B. NOTES:
1. ISSUANCE OF A BUILDING PERMIT BY THE CITY OF NEWPORT BEACH DOES NOT RELIEVE APPLICANTS OF THE LEGAL
REQUIREMENTS TO OBSERVE COVENANTS, CONDITIONS AND RESTRICTIONS WHICH MAY BE RECORDED AGAINST THE PROPERTY
OR TO OBTAIN PLANS YOU SHOULD CONTACT YOUR COMMUNITY ASSOCIATIONS PRIOR TO COMMENCEMENT OF ANY
CONSTRUCTION AUTHORIZED BY THIS PERMIT.
2. PRIOR TO PERFORMING ANY WORK IN THE CITY RIGHT-OF-WAY AN ENCROACHMENT PERMIT MUST BE OBTAINED FROM THE
PUBLIC WORKS DEPARTMENT.
3. A CAL-OSHA PERMIT IS REQUIRED FOR EXCAVATIONS DEEPER THAN 5' AND FOR SHORING AND UNDERPINNING.
4. ELECTRICAL SERVICE TO BE UNDERGROUND FOR NEW CONSTRUCTION, REPLACEMENT BUILDING OR ADDITIONS TO AN
EXISTING BUILDING EXCEEDING 50% OF THE GROSS FLOOR AREA OF THE EXISTING BUILDING. (NBMC 12.32.015)
5. FIELD INSPECTOR TO REVIEW AND APPROVE UNDERGROUND ELEC. SERVICE REQUIREMENT PRIOR TO CONCRETE PLACEMENT.
6. EDISON COMPANY APPROVAL IS REQUIRED FOR METER LOCATION PRIOR TO INSTALLATION.
LANDSCAPE NOTES:
1. ENCROACHMENT PERMIT REQ'D. FOR ANY WORK PROPOSED IN THE PUBLIC R.O.W.
2. IF APPLICABLE, REF. PRELIMINARY LANDSCAPE PLANS, FOR ALL HARDSCAPE & PLANTING AREAS WITH RESPECTIVE HEIGHTS
AND MATERIALS.
BAY ISLAND
NEWPORT BAY
15' - 0"
F.Y.S.B.
4' - 0"
EASEMENT
2'
-
6
"
EASEMENT
5'
-
0
"
EASEMENT
5' - 0"
R.Y.S.B.
18' - 0"
ESMT.
2'
-
6
"
1
1
1
1
2
2
3
4
5 5
6
6 77
7
7
7
EXISTING STRUCTURE -1 BAY ISLAND
(NOT A PART)
EXISTING STRUCTURE -2 BAY ISLAND
(NOT A PART)
1
S.Y.S.B.
8'
-
0
"
S.Y.S.B.
5'
-
0
"
CL
R
.
10
'
-
3
3
/
4
"
(20' MIN )
SLOPE PER CIVIL
SLOPE
PER CIVIL
DN.DN.
PLANTED AREA
PLANTED AREA
PLANTED AREA PLANTED AREA
PLANTED AREA
PLANTED AREA
PLANTED AREA
5
5
8
CART PARKING
DRIVEWAY
SL
O
P
E
2
%
M
I
N
.
9 9
9
45
°
0
0
'
0
0
"
38
.
3
9
'
N
W
52° 45' 36"44.75'
N E
45
°
0
0
'
0
0
"
56
.
2
0
'
N
W
45° 00' 00"89.00'S W
F.O.F.
3'
-
7
1
/
4
"
F.O.F.
6'
-
6
3
/
8
"
10.00' F.F.11.00' F.F.
9
PLANTED AREA
F.O.F.
5'
-
0
"
F.O
.
F
.
8'
-
6
"
F.O.F.
8'
-
0
"
F.O.F.
18' - 0"
EASEMENT
5'
-
0
"
S.Y.S.B.
6'
-
0
"
EASEMENT
5'
-
0
"
S.Y.S.B.
6'
-
0
"
10.48' FS
10.70' FS
11.22' FS
11.76' FS
12.26' FS
12.04' FS
12.67' FS
10
11
12
13 1313
14151616
9.87'
7.66' NG
36" MAX ABV. F.F.
7.66' NG
13.00' T.O. COUNTER
PLANTED AREA PLANTED AREA
DN.
PLANTED AREA
PLANTED AREA
SUNKEN FIREPIT
DECK
8
8
8
8
TRASH
SLOPE 2% MIN.
OUTDOOR SHOWER
SLOPE
2% MIN.
CLR.
13' - 4"
AWAY FROM THE BAY ISLAND PROPERTY LINE29' - 9 1/8"
7.58' T.O.S.
9.87'
10.05' T.W.
10.75' T.W.
11.50' T.W.
11.75' T.W.
13.00' T.W.
14.00' T.R.
14.78' T.W.
13.21' T.W.
17
10.47' FS
13.25' FS
7.41' NG
7.55' FF
10.00' F.F.
11.58' FS
8
8
18 SLOPE
PER CIVIL
EXISTING STRUCTURE -21 BAY ISLAND
(NOT A PART)
8.69' T.W.
12.00' T.W.
12.00' T.W.
13.50' T.W.
FRONT YARD "MINOR STRUCTURES" ENCOARCHMENT
PER UP3618 BAY ISLAND CLUB OFFICIAL MAP
NEW SINGLE FAMILY RESIDENCE
APN: 048 040 02
PARCEL 22 PORTION OF LOT 5, SECTION 34
19
STEP PER CIVIL
KITCHEN
GREAT ROOM DINING
PANTRY PWD. 1
C.C.
FOYER
CART GARAGE / GYM
STOR.
STAIRS
BEDROOM 1
BATH 1
PT. A
12.46' FS
PT. C
6.45' FS
PT. 1A
10.48' FS PT. 1B
10.70' FS PT. 1C
11.22' FS PT. 1D
11.76' FS PT. 1E
12.46' FS
PT. 1F
12.67' FS
PT. 1G
10.47' FS
PT. 1H
9.44' FS
PT. 1J
7.17' FS
PT. 1K
6.69' FS
PT. B
11.98' NG
PT. D
6.47' FS
7 9' - 8 5/8 "
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
SITE PLAN NOTESA
ANNOTATION LEGENDB
KEYNOTESC
BRANDON ARCHITECTS
01/20/2023
ARCHITECTURAL
SITE PLAN
MI
L
L
E
R
R
E
S
I
D
E
N
C
E
MR. & MRS. MATTHEW MILLER
22 BAY ISLAND,
NEWPORT BEACH, CA 92661
P: 949.235.9286
millermg123@gmail.com
CDP
22 BAY ISLAND
NEWPORT BEACH, CA 92661
A-0.0
TBD
BRIAN JOWETT
PROJECT NORTHTRUE NORTH
3/16" = 1'-0"1 ARCHITECTURAL SITE PLAN
1 BOUNDARY LINE
2 EASEMENT LINE
3 FRONT YARD SETBACK
4 REAR YARD SETBACK
5 SIDE YARD SETBACK
6 CENTERLINE OF STREET
7 FOOTPRINT OF EXISTING STRUCTURE, TO BE REMOVED
8 (N.) HARDSCAPE - STONE PAVERS (AS SELECTED)
9 (E.) SIDEWALK / GOLF CART STREET - PROTECT IN PLACE
10 (E.) TREE TO REMAIN - PROTECT IN PLACE
11 (E.) SEWER M.H. TO BE RELOCATED AS NEEDED - (REF. SURVEY & CIVIL DWGS.)
12 (E.) GAS METER LOCATION TO BE RELOCATED - (REF. SURVEY & CIVIL DWGS.)
13 (E.) GOLF CART ACCESS PATH TO REMAIN - PROTECT IN PLACE
14 BBQ - VERIFY APPLIANCE W/. OWNER
15 BASE CABINET & COUNTER - BUILT-IN, FINISH AS SEL.
16 REFRIGERATOR - UNDER-COUNTER, PER I.D. & OWNER
17 MAIN SERVICE PANEL, 400 AMP MAX. (MAINTAIN 36" CLEAR FROM FACE OF PANEL TO ANY OBSTRUCTION)
18 BISON DECKING SYSTEM OVER WESTCOAT ALX WATERPROOFING SYSTEM PER ICC# EST - 2201, REF. MAT. SCHED. A/A-4.0.
19 FIREPIT - PROVIDE GAS STUB-OUT, REF. LAND. DWGS., VERIFY W/. OWNER
PROJECT NORTHTRUE NORTH
1/8" = 1'-0"2 GRADE PLANE EXHIBIT
NO. REVISION DATE
PT 1A 10.48'
PT 1B 10.70'
PT 1C 11.22'
PT 1D 11.76'
PT 1E 12.46'
PT 1F 12.67'
PT 1G 10.47'
PT 1H 9.44'
PT 1J 7.17'
PT 1K 6.69'
103.06 / 10
GRADE PLANE = 10.31'
AVG. SLOPE (PT A -PT C)
(12.46' -6.45') / 79.72' = 7.5% SLOPE
EXISTING STRUCTURE
(TO BE DEMOLISHED)
NEWPORT BAY EXISTING DECK ABOVE
(TO BE DEMOLISHED)
B
A-0.2
B
A-0.2
B
A-0.2
1
2
3
4
5
5
6
6
6
7
8
92
10
EXISTING STRUCTURE -1 BAY ISLAND
(NOT A PART)
EXISTING STRUCTURE -2 BAY ISLAND
(NOT A PART)
EXISTING STRUCTURE -21 BAY ISLAND
(NOT A PART)
1. SITE TO BE FENCED ON ALL SIDES.
2. EXISTING SQUARE FOOTAGE OF BUILDING IS 3,3662 S.F.
3. EXISTING BEDROOM COUNT IS SIX (6).
4. ALL DEBRIS SHALL BE WET AT TIME OF HANDLING TO PREVENT DUST.
5. SEWER LINE SHALL BE CAPPED.
6. ALL BASEMENT FILL (IF APPLICABLE) SHALL BE CLEAN AND UNIFORM.
7. STREETS AND SIDEWALKS ARE TO REMAIN CLEAR AND CLEAN.
8. PEDESTRAIN CANOPY PROTECTION REQUIRED IF DEMOLITION WITHIN 10 FEET OF PUBLIC SIDEWALK.
9. INSTALL GRAVELBAGS, 2 BAGS HIGH (SE-6) AROUND THE PERIMETER OF THE PROPERTY.
10. EROSION CONTROL DEVICES SHALL BE AVAILABLE ON-SITE BETWEEN OCTOBER 15 AND MAY 15.
11. BETWEEN OCTOBER 15 AND MAY 15, EROSION CONTROL MEASURES SHALL BE IN PLACE AT THE END OF EACH WORKING
DAY WHENEVER THE FIVE-DAY PROBABILITY OF RAIN EXCEEDS 30%. DURING THE REMAINDER OF THE YEAR, THEY SHALL BE
IN PLACE AT THE END OF THE WORKING DAY, WHENEVER THE DAILY RAINFALL PROBABILITY EXCEEDS 50%.
12. TEMPORARY DESILTING BASINS, WHEN REQUIRED, SHALL BE INSTALLED AND MAINTAINED FOR THE DURATION OF THE
PROJECT.
2
B
A
G
S
M
I
N
.
1'
M
I
N
.
H
T
.
P.L.
SU
B
J
E
C
T
P
R
O
P
E
R
T
Y
ELEVATION SECTION
NOTE: GRAVEL BAGS PLACED PER DETAIL BELOW ARE MIN. REQUIREMENT & ADDITIONAL BAGS SHOULD
BE PLACED AT THE DESCRETION OF THE GENERAL CONTRACTOR & DEMO CONSULTANT IN RESPONSIBLE
CHARGE.
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
SITE PLAN NOTESA
ANNOTATION LEGENDB
KEYNOTESC
BRANDON ARCHITECTS
01/20/2023
DEMO PLAN
MI
L
L
E
R
R
E
S
I
D
E
N
C
E
MR. & MRS. MATTHEW MILLER
22 BAY ISLAND,
NEWPORT BEACH, CA 92661
P: 949.235.9286
millermg123@gmail.com
CDP
22 BAY ISLAND
NEWPORT BEACH, CA 92661
A-0.2
TBD
BRIAN JOWETT
PROJECT NORTHTRUE NORTH
3/16" = 1'-0"1 DEMO PLAN
1 OUTLINE OF EXISTING STRUCTURE - TO BE REMOVED
2 (E.) TREE - TO BE REMOVED.
3 (E.) GAS METER LOCATION TO BE RELOCATED - (REF. SURVEY & CIVIL DWGS.)
4 (E.) SEWER M.H. TO BE RELOCATED AS NEEDED - (REF. SURVEY & CIVIL DWGS.)
5 (E.) SITE BLOCK WALL - TO BE REMOVED
6 (E.) SITE STAIRS - TO BE REMOVED
7 (E.) TRASH ENCLOSURE - TO BE REMOVED
8 (E.) FOUNTAIN - TO BE RETURNED TO HOA
9 (E.) CURB - TO BE REMOVED
10 (E.) TREE TO REMAIN - PROTECT IN PLACE
SAND BAG DETAIL
DEMO PLAN NOTES
NO. REVISION DATE
UP
UP
DN
DN
1876 SF
FIRST FLOOR
279 SF
CART GARAGE
590 SF
DECK
A1
A4
A6
A9
A8
FIRST FLOOR AREA CALCULATIONS
A1 22' -10 1/4" x 34' -1 7/8" = 780.61 S.F.
A2 6' -10 1/8" x 1' -4 3/4" =9.55 S.F.
A3 16' -4 1/8" x 6' -9 1/4" =110.66 S.F.
A4 15' -7 5/8" x 24' -9 3/4" =387.95 S.F.
A5 8' -9 1/2" x 9' -10 3/8" = 86.73 S.F.
A6 9' -6 1/8" x 16' -0 3/8" = 152.46 S.F.
A7 10' -0 1/4" x 12' -3 1/8" =122.86 S.F.
A8 14' -8 3/8" x 15' -3 5/8" =224.91 S.F.
FIRST FLOOR LIVING AREA = 1,875.73 S.F.
A9 9' -3 1/8" x 12' -6 3/8" =116.04 S.F.
A10 14' -8 7/8" x 11' -0 3/8" = 162.6 S.F.
CART GARAGE AREA =278.64 S.F.
A11 6' -5 3/8" x 28' -10" =185.91 S.F.
A12 12' -6 5/8" x 32' -2" =403.76 S.F.
FIRST FLOOR OUTDOOR AREA =589.67 S.F.
A10
6' - 5 3/8"12' - 6 5/8"22' - 10 1/4"16' - 4 1/8"
A2
6' - 10 1/8"
1'
-
4
3
/
4
"
34
'
-
1
7
/
8
"
A3
A5
A7
6'
-
9
1
/
4
"
24
'
-
9
3
/
4
"
15' - 7 5/8"9' - 6 1/8"9' - 3 1/8"14' - 8 7/8"
16
'
-
0
3
/
8
"
9'
-
1
0
3
/
8
"
12
'
-
6
3
/
8
"
12
'
-
3
1
/
8
"
8' - 9 1/2"
10' - 0 1/4"14' - 8 3/8"
32
'
-
2
"
28
'
-
1
0
"
A11
A12
2063 SF
SECOND FLOOR
40 SF
BALCONY #3
40 SF
BALCONY #2
128 SF
MASTER BALCONY
B1 B2
B3
B4 B5
5' - 0"22' - 10 1/4"16' - 4"8' - 3"9' - 9 1/2"14' - 9 1/4"4' - 0"
34
'
-
2
"
SECOND FLOOR AREA CALCULATIONS
B1 22' -10 1/4" x 34' -2" = 780.85 S.F.
B2 16' -4" x 31' -7" = 515.86 S.F.
B3 8' -3" x 16' -4" = 134.75 S.F.
B4 9' -9 1/2" x 24' -9 1/2" = 242.75 S.F.
B5 14' -9 1/4" x 26' -4" = 388.97 S.F.
SECOND FLOOR LIVING AREA = 2,063.18 S.F.
B6 5' -0" x 25' -7" = 127.92 S.F.
B7 4' -0" x 10' -0" = 40 S.F.
B8 4' -0" x 10' -0" = 40 S.F.
SECOND FLOOR OUTDOOR AREA = 207.92 S.F.
B6
B7
B8
25
'
-
7
"
10
'
-
0
"
10
'
-
0
"
31
'
-
7
"
16
'
-
4
"
24
'
-
9
1
/
2
"
26
'
-
4
"
219 SF
ROOF DECK
50 SF
MECH WELL
337 SF
THIRD FLOOR
13' - 4 1/4"6' - 7 3/4"8' - 10 1/2"4' - 10"2' - 4 1/2"
14
'
-
0
1
/
2
"
4'
-
8
"
6'
-
3
"
C1 C2
C3
THIRD FLOOR AREA CALCULATIONS
C1 6' -7 3/4" x 14' -0 1/2" = 93.32 S.F.
C2 8' -10 1/2" x 14' -9" = 130.91 S.F.
C3 4' -10" x 10' -11" = 52.76 S.F.
C4 2' -4 1/2" x 4' -8" = 11.08 S.F.
C5 7' -2 1/2" x 6' -9 1/4" = 48.81 S.F.
THIRD FLOOR LIVING AREA = 336.88 S.F.
C6 13' -4 1/4" x 16' -5 1/8" =219.37 S.F.
C7 2' -4 1/2" x 6' -3" = 14.84 S.F.
C8 3' -3" x 10' -8" = 34.67 S.F.
THIRD FLOOR FLAT ROOF AREA =268.88 S.F.
C5
C6
10
'
-
1
1
"
6'
-
9
1
/
4
"
C7
C4
C816
'
-
5
1
/
8
"
7' - 2 1/2"3' - 3"
14
'
-
9
"
10
'
-
8
"
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
BRANDON ARCHITECTS
01/20/2023
AREA PLANS
MI
L
L
E
R
R
E
S
I
D
E
N
C
E
MR. & MRS. MATTHEW MILLER
22 BAY ISLAND,
NEWPORT BEACH, CA 92661
P: 949.235.9286
millermg123@gmail.com
CDP
22 BAY ISLAND
NEWPORT BEACH, CA 92661
A-0.3
TBD
BRIAN JOWETT
NO. REVISION DATE
3/16" = 1'-0"1 FIRST LEVEL AREA PLAN
3/16" = 1'-0"2 SECOND LEVEL AREA PLAN
3/16" = 1'-0"3 THIRD LEVEL AREA PLAN
PR
E
C
I
S
E
G
R
A
D
I
N
G
P
L
A
N
FO
R
P
R
O
P
O
S
E
D
R
E
S
I
D
E
N
C
E
22
B
A
Y
I
S
A
L
N
D
NE
W
P
O
R
T
B
E
A
C
H
,
C
A
9
2
6
6
1
JOB NO.
DATE
SHEET NO.
REVISIONS
22071
NO.REVISION DATE
SHEET NO. OF 3
1/12/2023
28
0
5
2
C
A
M
I
N
O
C
A
P
I
S
T
R
A
N
O
,
S
T
E
2
1
3
LA
G
U
N
A
N
I
G
U
E
L
,
C
A
9
2
6
7
7
94
9
.
4
6
4
.
8
1
1
5
i
n
f
o
@
c
i
v
i
l
s
c
a
p
e
s
.
c
o
m
G:
\
P
r
o
j
e
c
t
s
\
2
2
0
7
1
2
2
B
a
y
I
s
l
a
n
d
,
N
B
\
D
W
G
\
2
2
0
7
1
.
G
R
A
D
I
N
G
.
d
w
g
1
C1
TI
T
L
E
S
H
E
E
T
NO SCALE
1.ALL WORK SHALL CONFORM TO CHAPTER 15 OF THE NEWPORT BEACH MUNICIPAL CODE
(NBMC), THE PROJECT SOILS REPORT AND SPECIAL REQUIREMENTS OF THE PERMIT.
2.DUST SHALL BE CONTROLLED BY WATERING AND/OF JUST PALLIATIVE.
3.SANITARY FACILITIES SHALL BE MAINTAINED ON THE SITE DURING CONSTRUCTION PERIOD.
4.WORK HOURS ARE LIMITED FROM 7:00 AM TO 6:30 PM MONDAY THROUGH FRIDAY; 8:00
AM TO 6:00 PM SATURDAYS; AND NO WORK ON SUNDAYS AND HOLIDAYS PER SECTION
10-28 OF THE NBMC.
5.NOISE, EXCAVATION, DELIVERY AND REMOVAL SHALL BE CONTROLLED PER SECTION 10-28
OF THE NBMC.
6.THE STAMPED SET OF THE APPROVED PLANS SHALL BE ON THE JOB SITE AT ALL TIMES.
7.PERMITTEE AND CONTRACTOR ARE RESPONSIBLE FOR LOCATING AND PROTECTING
UTILITIES.
8.APPROVED SHORING, DRAINAGE PROVISION AND PROTECTIVE MEASURES MUST BE USED
TO PROTECT ADJOINING PROPERTIES DURING THE GRADING OPERATION.
9.CESSPOOLS AND SEPTIC TANKS SHALL BE ABANDONED IN COMPLIANCE WITH THE
UNIFORM PLUMBING CODE AND APPROVED BY THE BUILDING OFFICIAL.
10.HAUL ROUTES FOR IMPORT OR EXPORT OF MATERIALS SHALL BE APPROVED BY THE CITY
TRAFFIC ENGINEER AND PROCEDURES SHALL CONFORM WITH CHAPTER 15 OF THE NBMC.
11.POSITIVE DRAINAGE SHALL BE MAINTAINED AWAY FROM ALL BUILDINGS AND SLOPE
AREAS.
12.FAILURE TO REQUEST INSPECTIONS AND/OR HAVE REMOVABLE EROSION CONTROL
DEVICES ON-SITE AT THE APPROPRIATE TIMES SHALL RESULT IN A "STOP WORK" ORDER.
13.ALL PLASTIC DRAINAGE PIPES SHALL CONSIST OF PVC (SDR 35) WITH GLUED JOINTS.
14.NO PAINT, PLASTER, CEMENT, SOIL, MORTAR OR OTHER RESIDUE, SHALL BE ALLOWED TO
ENTER STREETS CURBS, GUTTERS OR STORM DRAINS. ALL MATERIALS AND WASTES SHALL
BE REMOVED FROM THE SITE.
GENERAL NOTES
VICINITY MAP
CITY OF NEWPORT BEACH, CALIFORNIA
COUNTY OF ORANGE
C1 TITLE SHEET
C2 GRADING PLAN
C3 CONSTRUCTION POLLUTION PREVENTION PLAN
SHEET INDEX
22 BAY ISLAND
NEWPORT BEACH, CA 92661
APN: 048-040-02
PRECISE GRADING PLAN
CIVILSCAPES ENGINEERING, INC
CONTACT: WILL ROLPH
28052 CAMINO CAPISTRANO, STE 213
LAGUNA NIGUEL, CA 92677
949.464.8115
EMAIL:will@civilscapes.com
CIVIL ENGINEER
1.CONSTRUCTION CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY
ACCEPTED CONSTRUCTION PRACTICES, CONSTRUCTION CONTRACTOR WILL BE
REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS
DURING THE COURSE OF CONSTRUCTION OF THE PROJECT, INCLUDING SAFETY OF ALL
PERSONS AND PROPERTY; THAT IS REQUIREMENT SHALL BE MADE TO APPLY
CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS.
2.NO UTILITY SEARCH WAS CONDUCTED. A UTILITY SEARCH BY THE CONTRACTOR SHALL
BE CONDUCTED AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO TAKE DUE
PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES OR STRUCTURES FOUND ON THE
SITE AND TO NOTIFY THE OWNERS OF THE UTILITIES IMMEDIATELY UPON THEIR
DISCOVERY.
3.EARTHWORK AND OTHER CONSTRUCTION ITEM QUANTITIES SHOWN ON THESE PLANS
ARE ESTIMATES FOR PERMITTING PURPOSES ONLY AND SHALL NOT USED FOR
CONSTRUCTION COST ESTIMATES OR FOR BIDDING PURPOSES. THE CONTRACTOR SHALL
DEVELOP OWN QUANTITIES FOR BIDDING PURPOSES.
4.A SOILS INVESTIGATION MUST BE MADE BY A QUALIFIED SOILS ENGINEER AND/OR
GEOLOGIST. SOIL AND EARTH ACCEPTABILITY ARE NOT UNDER PURVIEW OR THE
RESPONSIBILITY OF THE DESIGN ENGINEER FOR THIS PLAN. CIVILSCAPES ENGINEERING
DOES NOT TEST OR OBSERVE SOIL CONDITIONS PRIOR TO, DURING OR AFTER
CONSTRUCTION AND HAS NO RESPONSIBILITY FOR SOILS (EARTH) STRUCTURES.
5.ALL RETAINING WALL DESIGNS ARE TO BE BUILT PER STRUCTURAL ENGINEER'S PLAN AND
PER SEPARATE PLAN AND PERMIT.
6.REFER TO SOILS REPORT FOR GRADING RECOMMENDATIONS.
7.CONTRACTOR SHALL VERIFY EXISTING ELEVATION, PROTECT ALL EXISTING UTILITIES, AND
DOWNSTREAM DRAIN.
8.TOPOGRAPHIC SURVEY SHOWN HEREON FOR REFERENCE PURPOSES ONLY.
9.TOPOGRAPHIC SURVEY PREPARED BY: APEX LAND SURVEYING, INC., 8512 OXLEY CIRCLE,
HUNTINGTON BEACH, CA. PHONE: 714-488-5006.
10.VERIFY EXISTING TOPOGRAPHIC ELEVATIONS AND NOTIFY CIVILSCAPES ENGINEERING OF
ANY CONFLICTS PRIOR TO CONSTRUCTION.
11.NO UTILITY SEARCH WAS CONDUCTED. CONTRACTOR SHALL PROTECT UTILITIES OR
STRUCTURES FOUND ON THE SITE AND NOTIFY CIVILSCAPES ENGINEERING OF ANY
CONFLICTS.
12.EXTERIOR FOUNDATIONS WALLS SHALL COMPLY WITH THE DETAILS AS SHOWN BELOW:
13.PAD ELEVATION IS ASSUMED TO BE BASED ON ARCHITECTURAL FLOOR PLAN WITH AT
LEAST 5" THICK CONCRETE AND 4" THICK BASE WITH VAPOR BARRIER PER SOILS REPORT.
CONTRACTOR TO VERIFY WITH LATEST APPROVED SOILS REPORT AND STRUCTURAL
ENGINEER FOR EXACT SLAB RECOMMENDATIONS.
14.A PUBLIC WORKS DEPARTMENT ENCROACHMENT PERMIT INSPECTION IS REQUIRED
BEFORE THE BUILDING DEPARTMENT PERMIT FINAL CAN BE ISSUED. AT THE TIME OF
PUBLIC WORKS DEPARTMENT INSPECTION, IF AN OF THE EXISTING PUBLIC
IMPROVEMENTS SURROUNDING THE SITE IS DAMAGED, NEW CONCRETE SIDEWALK, CURB
AND GUTTER, AND ALLEY/STREET PAVEMENT WILL BE REQUIRED AND 100% PAID BY THE
OWNER. SAID DETERMINATION AND THE EXTENT OF THE REPAIR WORK SHALL BE MADE
AT THE DISCRETION OF THE PUBLIC WORKS INSPECTOR.
15.AN APPROVED ENCROACHMENT PERMIT IS REQUIRED FOR ALL WORK ACTIVITIES WITHIN
THE PUBLIC RIGHT OF WAY. AN ENCROACHMENT AGREEMENT IS REQUIRED FOR ALL
NON-STANDARD IMPROVEMENTS WITHIN THE PUBLIC RIGHT-OF-WAY.
16.ALL WORK RELATED TO WATER IN THE PUBLIC RIGHT-OF-WAY SHALL BE PERFORMED BY
A C-34 LICENSED PIPELINE CONTRACTOR OR AN A LICENSED GENERAL ENGINEERING
CONTRACTOR.
17.ALL WORK RELATED TO WASTEWATER IN THE PUBLIC RIGHT-OF-WAY SHALL BE
PERFORMED BY A C-42 LICENSED SANITATION SEWER CONTRACTOR OR AN A LICENSED
GENERAL ENGINEERING CONTRACTOR.
18.EXISTING STREET TREE(S) SHALL BE PROTECTED IN PLACE.
19.REMOVE EXISTING NON-GRASS PARKWAY ELEMENTS BETWEEN SIDEWALK AND CURB.
REPLACE WITH SOD TO MATCH EXISTING AS REQUIRED.
20.REFER TO SOILS REPORT FOR GRADING RECOMMENDATIONS AND OVER-EXCAVATION
REMOVALS AND COMPACTION REQUIREMENTS.
21.PIPE MATERIAL MAY BE SUBSTITUTED IF APPROVED BY ENGINEER.
22.INCLUDE ALL REQUIRED JOINTS AND FITTINGS. PER MANUFACTURER'S INSTALLATION
INSTRUCTIONS.
23.UTILITIES SHALL BE CONSTRUCTED AND INSTALLED PER CALIFORNIA PLUMBING CODE
AND CITY PLUMBING CODE. SERVICE LINES AND METER SIZES SHALL BE CONFIRMED BY
PLUMBING ENGINEER OR CONTRACTOR PRIOR TO CONSTRUCTION.
24.CONSTRUCT TRENCH, BEDDING, AND BACKFILL PER MANUFACTURER'S INSTALLATION
INSTRUCTIONS, ASTM D 2321, AND SOILS REPORT.
25. ALL FIXTURES, EQUIPMENT, PIPING AND MATERIALS SHALL BE LISTED.
26.CONTRACTOR SHALL VERIFY ELEVATION PRIOR TO CONSTRUCTION AND NOTIFY
ENGINEER OF ANY DISCREPANCIES.
27.ALL PRIVATE IRRIGATION SPRINKLER HEADS SHALL BE INSTALLED AND POSITIONED IN A
MANNER THAT WILL NOT CAUSE IRRIGATION OVERSPRAY ONTO THE PUBLIC
RIGHT-OF-WAY.
NOTES TO OWNER, CONTRACTOR, & ARCHITECT
EARTHWORK QUANTITIES
1.GRADED SLOPES SHALL BE NO STEEPER THAN 2 HORIZONTAL TO 1 VERTICAL.
2.FILL SLOPES SHALL BE COMPACTED TO NO LESS THAN 90 PERCENT RELATIVE
COMPACTION OUT TO THE FINISHED SURFACE.
3.ALL FILLS SHALL BE COMPACTED THROUGHOUT TO THE MINIMUM OF 90 PERCENT
RELATIVE COMPACTION AS DETERMINED BY ASTM TEST METHOD 1557, AND APPROVED
BY THE SOILS ENGINEER. COMPACTION TEST SHALL BE PERFORMED APPROXIMATELY
EVERY TWO FEET IN VERTICAL HEIGHT AND OF SUFFICIENT QUANTITY TO ATTEST TO THE
OVERALL COMPACTION EFFORT APPLIED TO THE FILL AREAS.
4.AREAS TO RECEIVE FILL SHALL BE CLEARED OF ALL VEGETATION AND DEBRIS, SCARIFIED
AND APPROVED BY THE SOILS ENGINEER PRIOR TO PLACING OF THE FILL.
5.FILLS SHALL BE KEYED OR BENCHED INTO COMPETENT MATERIAL.
6.ALL EXISTING FILLS SHALL BE APPROVED BY THE SOILS ENGINEER OR REMOVED BEFORE
ANY ADDITIONAL FILLS ARE ADDED.
7.ANY EXISTING IRRIGATION LINES AND CISTERNS SHALL BE REMOVED OR CRUSHED IN
PLACE AND BACKFILLED AND APPROVED BY THE SOILS ENGINEER.
8.THE EXACT LOCATION OF THE SUBDRAINS SHALL BE SURVEYED IN THE FIELD FOR LINE
AND GRADE.
9.ALL TRENCH BACKFILLS SHALL BE COMPACTED THROUGHOUT THE MINIMUM OF 90
PERCENT RELATIVE COMPACTION, AND APPROVED BY THE SOILS ENGINEER. THE
BUILDING DEPARTMENT MAY REQUIRE CORING OF CONCRETE FLATWORK PLACED OVER
UNTESTED BACKFILLS TO FACILITATE TESTING.
10.THE STOCKPILING OF EXCESS MATERIAL SHALL BE APPROVED BY THE BUILDING
DEPARTMENT.
11.ALL CUT SLOPES SHALL BE INVESTIGATED BOTH DURING AND AFTER GRADING BY AN
ENGINEERING GEOLOGIST TO DETERMINE IF ANY STABILITY PROBLEM EXISTS. SHOULD
EXCAVATION DISCLOSE ANY GEOLOGICAL HAZARDS OR POTENTIAL GEOLOGICAL
HAZARDS, THE ENGINEERING GEOLOGISTS SHALL RECOMMEND AND SUBMIT NECESSARY
TREATMENT TO THE BUILDING DEPARTMENT FOR APPROVAL.
12.WHERE SUPPORT OR BUTTRESSING OF CUT AND NATURAL SLOPE IS DETERMINED TO BE
NECESSARY BY THE ENGINEERING GEOLOGIST AND SOILS ENGINEER, THE SOILS
ENGINEER WILL OBTAIN APPROVAL OF DESIGN, LOCATIONS AND CALCULATIONS FROM
THE BUILDING DEPARTMENT PRIOR TO CONSTRUCTION.
13.THE ENGINEERING GEOLOGIST AND SOILS ENGINEER SHALL INSPECT AND TEST THE
CONSTRUCTION OF ALL BUTTRESS FILLS AND ATTEST TO THE STABILITY OF THE SLOPE
AND ADJACENT STRUCTURES UPON COMPLETION.
14.THE ENGINEERING GEOLOGIST SHALL PERFORM PERIODIC INSPECTIONS DURING
GRADING.
15.NOTIFICATION OF NONCOMPLIANCE: IF IN THE COURSE OF FULFILLING THEIR
RESPONSIBILITY, THE CIVIL ENGINEER, THE SOILS ENGINEER, THE ENGINEERING
GEOLOGIST OR THE TESTING AGENCY FINDS THAT THE WORK IS NOT BEING DONE IN
CONFORMANCE WITH THE APPROVED GRADING PLANS, THE DISCREPANCIES SHALL BE
REPORTED IMMEDIATELY IN WRITING TO THE PERSON IN CHARGE OF THE GRADING
WORK AND TO THE BUILDING INSPECTOR. RECOMMENDATIONS FOR CORRECTIVE
MEASURES, IF NECESSARY, SHALL BE SUBMITTED TO THE BUILDING DEPARTMENT FOR
APPROVAL.
GRADING NOTES
1.ALL LOOSE SOIL AND DEBRIS SHALL BE REMOVED FROM PAVED SURFACES. AREAS UPON
STARTING OPERATIONS, AND PERIODICALLY THEREAFTER.
2.SEDIMENT CONTROL MEASURES (I.E. GRAVEL BAGS OR EQUIVALENT) SHALL BE
IMPLEMENTED AT THE PERIMETER OF ALL DISTURBED SOIL AREAS TO CONTROL RUN-ON
AND RUN-OFF.
3.GRAVEL BAGS AND NECESSARY MATERIALS SHALL BE AVAILABLE ON SITE AND STOCKPILED
AT CONVENIENT LOCATIONS TO FACILITATE RAPID CONSTRUCTION OF TEMPORARY
DEVICES OR TO REPAIR ANY DAMAGED EROSION CONTROL MEASURES, WHEN RAIN IS
IMMINENT. A STAND-BY CREW SHALL BE MADE AVAILABLE AT ALL TIMES DURING THE
RAINY SEASON.
4.MATERIALS AND WASTE WITH THE POTENTIAL TO POLLUTE URBAN RUN-OFF SHALL BE
USED IN ACCORDANCE WITH LABEL DIRECTIONS AND SHALL BE STORED IN A MANNER
THAT EITHER PREVENTS CONTACT WITH RAINFALL OR CONTAINS CONTAMINATED
RUN-OFF FOR TREATMENT AND DISPOSAL.
EROSION CONTROL NOTES
SITE ADDRESS: 22 BAY ISLAND, NEWPORT BEACH
APN:048-040-02
GENERAL PLAN LAND USE: RM-D MULTIPLE RESIDENTIAL DETACHED
ZONING DISTRICT: RM MULTIPLE RESIDENTIAL
COASTAL ZONE: YES
SITE DATA:ISSUANCE OF A BUILDING PERMIT BY THE CITY OF NEWPORT BEACH DOES NOT RELIEVE
APPLICANTS OF THE LEGAL REQUIREMENTS TO OBSERVE COVENANTS, CONDITIONS AND
RESTRICTIONS WHICH MAY BE RECORDED AGAINST THE PROPERTY OR TO OBTAIN
PLANS. YOU SHOULD CONTACT YOUR COMMUNITY ASSOCIATIONS PRIOR TO
COMMENCEMENT OF ANY CONSTRUCTION AUTHORIZED BY THIS PERMIT.
CC&R'S
1.PRIOR TO PERFORMING AND WORK IN THE CITY RIGHT-OF-WAY AN
ENCROACHMENT PERMIT MUST BE OBTAINED FROM THE PUBLIC WORKS
DEPARTMENT.
2.A PUBLIC WORKS DEPARTMENT ENCROACHMENT PERMIT INSPECTION IS REQUIRED
BEFORE THE BUILDING DEPARTMENT PERMIT FINAL CAN BE ISSUED. AT THE TIME OF
PUBLIC WORKS DEPARTMENT INSPECTION, IF ANY OF THE EXISTING PUBLIC
IMPROVEMENTS SURROUNDING THE SITE IS DAMAGED, NEW CONCRETE SIDEWALK,
CURB AND GUTTER, AND ALLEY/STREET PAVEMENT WILL BE REQUIRED.
ADDITIONALLY, IF EXISTING UTILITIES INFRASTRUCTURE ARE DEEMED SUBSTANDARD,
A NEW 1-INCH WATER SERVICE, WATER METER BOX, SEWER LATERAL AND/OR
CLEANOUT WITH BOX AND LID WILL BE REQUIRED. 100% OF THE COST SHALL BE
BORNE BY THE PROPERTY OWNER (MUNICIPAL CODES 14.24.020 AND 14.08.030).
SAID DETERMINATION AND THE EXTENT OF THE REPAIR WORK SHALL BE MADE AT
THE DISCRETION OF THE PUBLIC WORKS INSPECTOR. CONTRACTOR IS RESPONSIBLE
TO MAINTAIN THE PUBLIC RIGHT OF WAY AT ALL TIMES DURING THE
CONSTRUCTION PROJECT. A STOP WORK NOTICE MAY BE ISSUED FOR ANY DAMAGE
OR UNMAINTAINED PORTION OF THE PUBLIC RIGHT OF WAY.
3.AN ENCROACHMENT AGREEMENT IS REQUIRED FOR ALL NON-STANDARD
IMPROVEMENTS WITHIN THE PUBLIC RIGHT OF WAY. ALL NON-STANDARD
IMPROVEMENTS SHALL COMPLY WITH CITY COUNCIL POLICY L-6 AND L-18.
4.CONTRACTOR REMOVE ALL EXISTING DECORATIVE MATERIAL WITHIN THE PUBLIC
RIGHT-OF-WAY.
5.ALL LANDSCAPING WITHIN THE PUBLIC RIGHT-OF-WAY SHALL HAVE A MAXIMUM
GROWTH CHARACTERISTIC OF 36-INCHES.
6.ALL PRIVATE IRRIGATION SPRINKLER HEADS SHALL BE INSTALLED AND POSITIONED
IN A MONNER THAT WILL NOT CAUSE IRRIGATION OVERSPRAY ONTO THE PUBLIC
RIGHT-OF-WAY.
PUBLIC WORKS NOTES
ARCHITECT
BRANDON ARCHITECTS
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
RAW CUT 105 CUBIC YARDS
RAW FILL 190 CUBIC YARDS
NET 85 CUBIC YARDS (IMPORT)
NOTE:
SURVEYOR OR ENGINEER SHALL PERMANENTLY
MONUMENT PROPERTY CORNERS OR OFFSETS
BEFORE GRADING.
APEX LAND SURVEYING, INC.
HUNTINGTON BEACH, CA 92646
714.488.5006
SURVEYOR
CONTRACTOR'S NOTE:
CONTRACTOR SHALL, USE CITY STANDARD FORM '30-DAY NOTICE OF INTENT TO
EXCAVATE' TO, NOTIFY ADJACENT PROPERTY OWNERS BY CERTIFIED MAIL 30 DAYS
PRIOR TO STARTING EXCAVATION OR SHORING. CITY STANDARD FORM CAN BE
OBTAINED AT: http://www.newportbeachca.gov/home/showdocument?id=17395.
PROOF OF CERTIFIED DELIVERY IS REQUIRED AT THE TIME OF PERMIT ISSUANCE.
PROJECT SITE22 BAY ISLAND
L1
L2
L3
PARCEL 1
PARCEL 2
BAYISLAND
N6
1
°
3
9
'
2
3
"
W
5
6
.
3
0
'
N28°16'42"E 89.03'
N36°11'09"E 94.
8
5
'
R @0' - 6"2
R @0' - 7 1/2"18
PROPOSED RESIDENCE
FF=10.00FF
=
1
0
.
0
0
FS
=
9
.
7
5
(12.37)FS
7.56FS,BOT
FS
=
9
.
6
6
(13.19)FS,JOIN
(13.30)FS,JOIN
(11.45)FS(11.31)FS (11.58)FS
EXISTING PORTION OF WALKWAYTO BE REGRADED PER SEPARATEPLAN AND PERMIT
PROPERTY LINE
PROPERTY LINE PROPERTY LINE
EXISTING WALKWAYTO REMAIN
EXISTING WALKWAYTO REMAIN
(13.14)FS,JOIN
EXISTING WALKWAYTO REMAIN
EXISTING WALKWAYTO REMAIN
(13.09)FS12.85FG
6" STEPS(2 EACH)
6-1/2" STEPS(4 EACH)
4 3
2.0%
2.0%
1
(11.11)FS
8.78FS
(10.25)FS,JOIN
(10.28)FS,JOIN
(9.26)FS
9.07GFF9.01FS
(9.52)FS
8.78FS (9.35)FS
(7.00)FS,JOIN
(6.92)FS,JOIN 7.22FS
7.34FS
7.44FS
7.58FS
7.33FS
7.34FS
7.59FS7.47FS
7.53FL 8.72FL,GB
5.7%
2.0%
2.0%
2.0%
2.0%
4.4%
2%2%
2%2%
EXISTING PORTION OF WALKWAYTO BE REGRADED PER SEPARATEPLAN AND PERMIT
EXISTING WALKWAYTO REMAIN
EXISTING WALLTO BE REMOVED
EXISTING WALLTO BE REMOVED
11.00FF10.96FS1/2"STEP
(12.67)FS
11.50TW
10.75TW
10.75TW(10.5)FS(7.6)NG
11.75TW 13.00TW
14.78TW9.75FS,TOP
11.57FS10.99FS7"STEP
2.
0
%
2.0%
TG
=
9
.
5
2
9.55FS,TOP
10.05TW7.58FS7.54FG
7.66FG
7.67FS,BOT
7-1/2" STEPS(3 EACH)
2.0%
7.58FS7.54FG
7.58FS7.54FG 7.70FSFIREPIT
9.75FS
(10.5)FS
9.75FS
9.60FS9.56FG
9.60FS9.56FG
2.
0
%
2.
0
%
9.75FS,BOT
10.92FS,TOP
2.
0
%
1.
0
%
GFF=11.32
GFF=11.43
TG=11.28
(12.30)FS
(11.55)FS
10
%
(12.03)FS
11.45GFF11.00FF5-3/8"STEP
GFF=11.45
11.32GFF11.28TG1/2"STEP
3.
6
%
11.28FS
2.
3
%
2.0
%
11.18TG10.68INV
2.0%
2.0%
(10.7)FS
2.0
%
9.47TG7.85INV
10.66TG7.96INV
10.82FG
2.0
%
10.93FG11.67TS 11.67TS11.25TS
11.50TG
12.75TG9.95INV
13.25FS
10.99FS
10.86TG9.80INV
11.03FS,BOT
10.80TG9.90INV
11.91TG
12.03FS,TOP 12.53FS12.03FS6"STEP
12.49FG
12.52FG
12.86FS12.82FG
12.36TG10.18INV
12.70TG
12.60TG
12.25TG10.46INV
2.0%
2.0%
2.0%
14.78TW12.30FG
5.0%
12.80FS12.73FG
12.86FS12.82FG
12.80FS12.73FG
12.78TG10.31INV
1.
0
%
3.
5
%
7.3%
5.0%
9.45TG7.65INV
10.75TW7.70FG
9.45TG8.05INV 13.21TW9.50FG
1
1
1 1
1
1
1
2
3
3
3
3
3
3
3
3
4
4
4
5
55
11.67TS 11.67TS 12.67TS
12.67TS13.50TS
13.50TS
11.67TS
11.67TS11.67TS
5 5 5
5
5
5
5
55
6
7
8
8
8
8
88
8
8
8
8
8
9
8
9
9.65FG
9.55FG
12.90FG
13.00TW
3
FF=11.00
(7.18)FS
10.05TW7.54FG
13.21TW11.18FS
9
9.47TG7.74INV8
12.60FS
2.0
%
6
2.
0
%
L1
L2
L3
PARCEL 1
PARCEL 2
ISLAND
N6
1
°
3
9
'
2
3
"
W
5
6
.
3
0
'
N28°16'42"E 89.03'
N36°11'09"E 94
.
8
5
'
R @0' - 6"2
R @0' - 7 1/2"18
PROPOSED RESIDENCE
FF=10.00
OUTLET STORM DRAINTHROUGH WALL
8.78FS
(10.25)FS,JOIN
(10.28)FS,JOIN
(9.26)FS
9.07GFF9.01FS
(9.52)FS
8.78FS (9.35)FS
(7.00)FS,JOIN
(6.92)FS,JOIN 7.22FS
7.34FS
7.44FS
7.58FS
7.33FS
7.34FS
7.59FS7.47FS
7.53FL 8.72FL,GB
5.7%
2.0%
2.0%
2.0%
2.0%
4.4%
2%2%
2%2%
11.18TG10.68INV
9.47TG7.85INV
10.66TG7.96INV
11.50TG
12.75TG9.95INV
10.86TG9.80INV
10.80TG9.90INV
11.91TG
12.36TG10.18INV
12.70TG
12.60TG
12.25TG10.46INV
12.78TG10.31INV
9.45TG7.65INV
7.93INV
9.63INV,GB
10.75TW7.60INV7.50FG
9.45TG8.05INV
S=0.01
S=0.01 S=0.01
S=0.01
S=
0
.
0
1
S=
0
.
0
1
S=
0
.
0
1
S=0.01
7
8
8
8
8
88
8
8
8
8
8
9
8
9
10 10
10
10
10
10
111111
11
11 11
11 11
11
14
14
OUTLET SUBDRAIN TOSTORM DRAIN SYSTEM
15
15
15
15
15
FF=11.00
9
9.47TG7.74INV8
2
C2
GR
A
D
I
N
G
P
L
A
N
PR
E
C
I
S
E
G
R
A
D
I
N
G
P
L
A
N
FO
R
P
R
O
P
O
S
E
D
R
E
S
I
D
E
N
C
E
22
B
A
Y
I
S
A
L
N
D
NE
W
P
O
R
T
B
E
A
C
H
,
C
A
9
2
6
6
1
JOB NO.
DATE
SHEET NO.
REVISIONS
22071
NO.REVISION DATE
SHEET NO. OF 3
1/12/2023
28
0
5
2
C
A
M
I
N
O
C
A
P
I
S
T
R
A
N
O
,
S
T
E
2
1
3
LA
G
U
N
A
N
I
G
U
E
L
,
C
A
9
2
6
7
7
94
9
.
4
6
4
.
8
1
1
5
i
n
f
o
@
c
i
v
i
l
s
c
a
p
e
s
.
c
o
m
G:
\
P
r
o
j
e
c
t
s
\
2
2
0
7
1
2
2
B
a
y
I
s
l
a
n
d
,
N
B
\
D
W
G
\
2
2
0
7
1
.
G
R
A
D
I
N
G
.
d
w
g
CONSTRUCTION NOTES
HARDSCAPE PER ARCHITECT'S PLAN.
DRIVEWAY PER ARCHITECT'S PLAN.
PLANTER AREA PER ARCHITECT'S PLAN.
WALL OR FENCE PER ARCHITECT'S PLAN.
CONSTRUCT CONCRETE STEMWALL PER STRUCTURAL PLAN AND DETAIL HEREON.
CONSTRUCT FLOWLINE PER DETAIL HEREON.
6-INCH WIDE NDS TRENCH DRAIN W/ TRAFFIC RATED GRATE.
FURNISH & INSTALL 6" NDS SPEE-D BASIN W/6" GREEN ATRIUM GRATE PER DETAIL ON SHEET C3.
FURNISH & INSTALL 6" NDS SPEE-D BASIN W/6" BRASS SQUARE GRATE PER DETAIL ON SHEET C3.
FURNISH & INSTALL 4-INCH SCH-40 PVC STORM DRAIN (OR APPROVED EQUAL) PER CPC. INCLUDE REQUIRED
JOINTS AND FITTINGS PER CPC. CONSTRUCT TRENCH, BEDDING, AND BACKFILL PER ASTM D 2321 AND SOILS
REPORT.
CONNECT DOWNSPOUT TO ONSITE STORM DRAIN SYSTEM PER DETAIL HEREON. OTHERWISE OUTLET TO
SPLASHBLOCK IN DIRECTION OF FLOW.
IF EXISTING METER IS SUBSTANDARD, REMOVE AND REINSTALL 1-INCH WATER METER PER CITY OF NEWPORT
BEACH STANDARD DRAWING STD-502-L. PROTECT SERVICE LINE FROM METER TO WATER MAIN. METER AND
SERVICE SIZE SHALL BE CONFIRMED BY MEP CONSULTANT.
FIELD VERIFY LOCATION AND CONDITION OF EXISTING SEWER LATERAL TO SATISFACTION OF CITY ENGINEER.
REMOVE EXISTING CLEANOUT AND PROVIDE NEW SEWER CLEANOUT WITH TRAFFIC RATED BOX PER CITY OF
NEWPORT BEACH STANDARD DRAWING STD-406-L.
CONSTRUCT 15 LINEAR FEET OF PERFORATED PIPE AND GRAVEL TRENCH PER DETAIL HEREON.
FURNISH & INSTALL 4-INCH PERFORATED PVC SUBDRAIN (OR APPROVED EQUAL) PER CPC. INCLUDE REQUIRED
JOINTS AND FITTINGS PER CPC. CONSTRUCT TRENCH, BEDDING, AND BACKFILL PER ASTM D 2321 AND SOILS
REPORT.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
TOP OF WALL
FINISHED SURFACE
FLOW LINE
FINISHED GRADE
GRADE BREAK
HIGH POINT
LEGEND
INVERT
TOP OF GRATE
FINISHED FLOOR ELEVATION
TW
FS
FL
FG
GB
HP
INV
TG
FF
TOP OF COPING OR TOP OF CURBTC
GARAGE FINISHED FLOORGFF
PROPERTY LINE AND LIMIT-OF-WORK
OR
EXISTING ELEVATION; CONTRACTOR SHALL FIELD
VERIFY ELEVATIONS PRIOR TO CONSTRUCTION
AND REPORT ANY DISCREPANCIES TO
CIVILSCAPES ENGINEERING102.6
(102.6)
EXISTING GRADEEG
EXISTING SPOT ELEVATION( )
PROPOSED WALL
TOP OF RETAINING WALLTRW
TOP OF SLOPETOP
TOP OF RAILINGTR
TOP OF STEMWALLTS
BUILDING STEMWALL
ALL WORK RELATED TO WASTEWATER IN THE PUBLIC RIGHT-OF-WAY SHALL BE
PERFORMED BY A C-42 LICENSED SANITATION SEWER CONTRACTOR OR AN A
LICENSED GENERAL ENGINEERING CONTRACTOR.
***
ALL WORK RELATED TO WATER IN THE PUBLIC RIGHT-OF-WAY SHALL BE
PERFORMED BY A C-34 LICENSED PIPELINE CONTRACTOR OR AN A LICENSED
GENERAL ENGINEERING CONTRACTOR.
****
***
****
1.CAL-OSHA PERMIT IS REQUIRED FOR EXCAVATIONS DEEPER THAN 5’ AND FOR SHORING
AND/OR UNDERPINNING.
2.CONTINUOUS SPECIAL INSPECTION, PER SECTION 1705.6, SHALL BE PERFORMED BY THE
GEOTECHNICAL ENGINEER DURING SHORING AND EXCAVATION OPERATIONS AND
DURING REMOVAL OF SHORING.
TRENCH AND EXCAVATION NOTE
ANY CHANGES TO THE HARDSCAPE/LANDSCAPE MUST BE INDICATED ON
A REVISED PRECISE GRADING PLAN, APPROVED BY THE CITY, AND MAY
TRIGGER A WATER QUALITY MANAGEMENT PLAN (WQMP) CONSISTENT
WITH THE MODEL WQMP, EXHIBIT 7.II.
WQMP NOTE
CONRETE HARDSCAPE
PERMEABLE GRASSPAVE2 SURFACE
“CONTRACTOR SHALL, USE THE CITY STANDARD FORM ‘30-DAY NOTICE OF INTENT TO
EXCAVATE’ TO, NOTIFY ADJACENT PROPERTY OWNERS BY CERTIFIED MAIL 30 DAYS PRIOR TO
STARTING EXCAVATION OR SHORING. CITY STANDARD FORM CAN BE OBTAINED AT:
HTTP://WWW.NEWPORTBEACHCA.GOV/HOME/SHOWDOCUMENT?ID=17395. PROOF OF
CERTIFIED DELIVERY IS REQUIRED AT THE TIME OF PERMIT ISSUANCE.”
30-DAY NOTICE TO EXCAVATE
3-INCH PVC DOWNSPOUT
DRAIN PIPE PER STORM DRAIN PLAN
4-INCH ELBOW 1/4 BEND
4-INCH PVC RISER WITH
DOWNSPOUT INSIDE RISER PIPE
CLAMPS AROUND RISER PIPE (TYP)
PROP. BUILDING
WALL
DOWNSPOUT CONNECTION DETAIL
NO SCALE11
GRADING PLAN
SCALE: 1" = 8'
STORM DRAIN PLAN
SCALE: 1" = 8'
FL PERPLAN
2% MIN.
HARDSCAPE/LANDSCAPE
PER PLAN
2% MIN.
FLOWLINE DETAIL
NO SCALE6
FINISHED FLOOR/ADJACENT GRADE DETAIL
NO SCALE
FINISHED SURFACE
FINISHED FLOOR
FINISHED GRADE
FINISHED FLOOR
**
**CONSTRUCT STEM WALL AS NECESSARY TO PROVIDE MINIMUM
SEPARATION DISTANCE BETWEEN WOOD SHEATHING AND SURFACE
PER 2016 CRC SECTION R317.1. FOUNDATIONS WITH STEM WALLS
SHALL HAVE ONE NO. 4 BAR WITHIN 12 INCHES FROM TOP OF WALL
AND ONE NO. 4 BAR LOCATED 3 TO 4 INCHES FROM BOTTOM OF
FOOTING (MINIMUM) PER 2019 CRC SECTION R403.1.3.1. REFER TO
STRUCTURAL DRAWINGS FOR DETAILS.
**
******
*VERTICAL DISTANCE PER 2019 CRC SECTION R317.1 MAY BE REDUCED
PROVIDED THAT WOOD FRAMING MEMBERS, INCLUDING WOOD
SHEATHING, THAT REST ON EXTERIOR FOUNDATION WALLS ARE
MADE OF NATURAL DURABLE OR PRESERVATIVE-TREATED WOOD IN
ACCORDANCE WITH CODE. CONTRACTOR SHALL NOTIFY
CIVILSCAPES ENGINEERING IF THERE ARE ANY CONFLICTS
*** MINIMUM GRADE AWAY FROM FOUNDATION SHALL BE PER 2019 CRC
SECTION R401.3. CONTRACTOR SHALL NOTIFY CIVILSCAPES
ENGINEERING IF THERE ARE ANY CONFLICTS.
5
L1
L2
L3
PARCEL 1
PARCEL 2
ISLAND
N6
1
°
3
9
'
2
3
"
W
5
6
.
3
0
'
N28°16'42"E 89.03'
N36°11'09"E 94.
8
5
'
R @0' - 6"2
R @0' - 7 1/2"18
PROPOSED RESIDENCE
FF=10.00
FF=11.00
FA
C
E
O
F
P
R
O
P
.
B
L
D
G
W
A
L
L
FF=11.00
P/L
SECTION A-A
SCALE: 1"=4'
EXISTING
GROUND 12.67TS
11.93FG
12.03FS
13.00TW 13.00TW
12.90FG
(12.09)FS FA
C
E
O
F
P
R
O
P
.
B
L
D
G
W
A
L
L
FF=11.00
P/L
EXISTING
BUILDING
(ADJACENT
NEIGHBOR)
(11.55)FS
EXISTING WALKWAY
TO REMAIN
SECTION B-B
SCALE: 1"=4'
EXISTING
GROUND
11.32GFF11.28TGFA
C
E
O
F
P
R
O
P
.
G
A
R
A
G
E
D
O
O
R
11.43GFF1.0%3.6%
FA
C
E
O
F
P
R
O
P
.
B
L
D
G
W
A
L
L
FF=11.00
EXISTING
GROUND
13.50TS12.83FS 12.78TG
12.83FS 13.25FS,JOIN12.80FS12.66FL
2.0%5.0%
P/L
EXISTING WALKWAY
TO REMAIN
SECTION C-C
SCALE: 1"=4'
3
C3
CO
N
S
T
R
U
C
T
I
O
N
P
O
L
L
U
T
I
O
N
P
R
E
V
E
N
T
I
O
N
P
L
A
N
PR
E
C
I
S
E
G
R
A
D
I
N
G
P
L
A
N
FO
R
P
R
O
P
O
S
E
D
R
E
S
I
D
E
N
C
E
22
B
A
Y
I
S
A
L
N
D
NE
W
P
O
R
T
B
E
A
C
H
,
C
A
9
2
6
6
1
JOB NO.
DATE
SHEET NO.
REVISIONS
22071
NO.REVISION DATE
SHEET NO. OF 3
1/12/2023
28
0
5
2
C
A
M
I
N
O
C
A
P
I
S
T
R
A
N
O
,
S
T
E
2
1
3
LA
G
U
N
A
N
I
G
U
E
L
,
C
A
9
2
6
7
7
94
9
.
4
6
4
.
8
1
1
5
i
n
f
o
@
c
i
v
i
l
s
c
a
p
e
s
.
c
o
m
G:
\
P
r
o
j
e
c
t
s
\
2
2
0
7
1
2
2
B
a
y
I
s
l
a
n
d
,
N
B
\
D
W
G
\
2
2
0
7
1
.
G
R
A
D
I
N
G
.
d
w
g
1.CONTRACTOR SHALL PROVIDE ONSITE CONCRETE WASHOUT FACILITY AND COMPLY WITH
CASQA BMP WM-8.
2.ALL REMOVABLE EROSION PROTECTIVE DEVICES SHALL BE IN PLACE AT THE END OF EACH
WORKING DAY WHEN THE 5-DAY RAIN PROBABILITY FORECAST EXCEEDS 40%.
3.SEDIMENTS FROM AREAS DISTURBED BY CONSTRUCTION SHALL BE RETAINED ON SITE USING
AN EFFECTIVE COMBINATION OF EROSION AND SEDIMENT CONTROLS TO THE MAXIMUM EXTENT
PRACTICABLE, AND STOCKPILES OF SOIL SHALL BE PROPERLY CONTAINED TO MINIMIZE SEDIMENT
TRANSPORT FROM THE SITE TO STREETS, DRAINAGE FACILITIES OF ADJACENT PROPERTIES VIA
RUNOFF, VEHICLE TRACKING, OR WIND.
3.APPROPRIATE BMPS FOR CONSTRUCTION-RELATED MATERIALS, WASTES, SPILLS OR RESIDUES
SHALL BE IMPLEMENTED AND RETAINED ON SITE TO MINIMIZE TRANSPORT FROM THE SITE TO
STREETS, DRAINAGE FACILITIES, OR ADJOINING PROPERTY BY WIND OR RUNOFF.
NOTES:
GRAVEL BAG DETAIL
NO SCALEA
EROSION CONTROL CONSTRUCTION NOTES
INSTALL GRAVEL BAG BARRIER PER CASQA SE-8 AND SE-6
INLET PROTECTION PER DETAIL HEREON
A
B
AREA DRAIN INLET PROJECTION
NO SCALE
B
A
A
A
A
NDS SPEE-D BASIN DETAIL
NO SCALE98
2% MIN
3/4" CRUSHED ROCK OR APPROVED
EQUAL (REVIEW GEOTECHNICAL
RECOMMENDATIONS IN THE SOILS
REPORT TO VERIFY)
DRAIN PIPE PER PLAN
COMPACTED BACKFILL
PER GEOTECHNICAL
RECOMMENDATIONS
COMPACTED BEDDING
PER GEOTECHNICAL
RECOMMENDATIONS
NATIVE OR RE-COMPACTED SUBGRADE
4" MIN 4" MIN
4"
M
I
N
NDS #101 OR #201
SPEE-D BASIN
OR APPROVED
EQUAL
NDS #66 - 6" DRAIN RISER PIPE (LENGTH
AS REQUIRED) OR APPROVED EQUAL
VA
R
I
E
S
2% MIN
NDS ATRIUM OR FLAT GRATE
TG ELEV
PER PLAN
INV ELEV
PER PLAN
SLOPE PER PLAN
LANDSCAPING OR PAVERS
3" COVER MINIMUM
4" DIA. PERFORATED PVC DRAIN PIPE
W/ PERFORATIONS AT BOTTOM
3/4" CRUSHED ROCK
WRAP SIDES AND BOTTOM OF
TRENCH WITH FILTER FABRIC; PROVIDE
4" MINIMUM OVERLAP AT TOP OF
TRENCH
PERFORATED DRAIN PIPE AND TRENCH
NO SCALE14
B
B
B
B
B
B
BB
BB
B
B
B
B
B
B
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
BRANDON ARCHITECTS
01/20/2023
3D VIEWS
MI
L
L
E
R
R
E
S
I
D
E
N
C
E
MR. & MRS. MATTHEW MILLER
22 BAY ISLAND,
NEWPORT BEACH, CA 92661
P: 949.235.9286
millermg123@gmail.com
CDP
22 BAY ISLAND
NEWPORT BEACH, CA 92661
A-1.0
TBD
BRIAN JOWETT
NO. REVISION DATE
1 AXONOMETRIC - N 2 AXONOMETRIC - E
3 AXONOMETRIC - S 4 AXONOMETRIC - W
DN
UP
A-4.1
A-4.0
A-4.03A-4.1
1
1
2
1
A-5.0
1
A-5.0
3
A-5.0
3
A-5.0
2
A-5.0
2
A-5.0
PANTRY
KITCHEN
DININGGREAT ROOM
ENTRY
CL
R
.
10
'
-
3
3
/
4
"
F.Y.S.B.
4' - 0"
R.Y.S.B.
18' - 0"
S.Y.S.B.
8'
-
0
"
S.Y.S.B.
5'
-
0
"
SL
O
P
E
2%
M
I
N
.
SLOPE PER CIVIL NOTE: PROVIDE MIN. (1)
LAYER 5/8" MOLD TOUGH VHI
FIRECODE 'X' BD. TO INSDIE
FACE OF ALL GARAGE WALLS
10.00' F.F.11.00' F.F.11.00' F.F.
S.Y.S.B.
6'
-
0
"
S.Y.S.B.
6'
-
0
"
R @ 0' -6"2
CART GARAGE / GYM
BEDROOM 1
STAIRS
STOR.
FOYER
BATH 1
PWD. 1
1
1
1
1
2
2
2 2
3
4
5
6
6
6
7
8
9
10
11
11
CLR.
30" MIN.
12
4
1 2
3 4
5
6 7
8
23
9
10
10
11
8
13 14
1516
16
1616
16 16 16
16
16
17
12
1618
19
18
18
R @ 0' -7 1/2"18
9
13 1214
5
6
7
C.C.
CLR.
13' - 4"
14.00' T.W.
11
1
ROOM TAGROOM NAME
1
A-5.0
1 1
?
1
1
A-4.0
1
1 1
1
ELEVATION / SECTION INDICATOR
AD-1.0
1 CALL-OUT TAG
10.00'SPOT ELEVATION
KEYNOTE TAG
REVISION TAG
DOOR / WINDOW / WINDOW WALL TAG
FIRE RATED CEILING ASS'Y -REF. DTLS. 8/AD-1.0
1-HR RATED INT CONDITION -REF. DTLS. 8/AD-1.0
1-HR RATED EXT CONDITION -REF. DTLS. 12/AD-1.0
STRUCTURAL STEEL COLUMN PER STRUCT., REF. STRUTC.
DWGS, -PAINT AND SEAL AS REQUIRED –ARCH. TO APPV.
COLOR FOR EXPOSED STEEL COLUMNS
STRUCTURAL WOOD POST/COLUMN COLUMN -PER STRUCT., REF. STRUTC. DWGS, -
PAINT, STAIN AND SEAL AS REQUIRED –ARCH. TO APPV. PAINT COLOR FOR EXPOSED
WOOD POST/COLUMN, IF TO BE STAINED PROVIDE STAINED SAMPLE FOR ARCH,
APPROVAL
DOORS -AS SPECIFIED, SEE WINDOW SCHEDULE AND GENERAL NOTES ON SHEET A-7.0 -
SHGC & U-FCTOR PER T-24 ENERGY REPORT – SEE SHEET AD-2.0 FOR JAMB, HEAD AND
THRESHOLD DETAILS, PROVIDE FLASHING AND WATERPROOFING AT DOOR OPENING PER
THE DOOR MFGR. INSTRUCTION AND/OR FLASHING MFGR. INSTRUCTION PER SECTIONS
R609.1 & R703.4 OF CRC
WINDOW -AS SPECIFIED, SEE WINDOW SCHEDULE AND GENERAL NOTES ON
SHEET A-7.0 -SHGC & U-FCTOR PER T-24 ENERGY REPORT – SEE SHEET
AD-2.0 FOR JAMB, HEAD AND SILL DETAILS, PROVIDE FLASHING AND
WATERPROOFING AT WINDOW OPENING PER THE WINDOW MFGR.
INSTRUCTION AND/OR FLASHING MFGR. INSTRUCTION PER SECTIONS R609.1
& R703.4 OF CRC
KITCHEN RANGE W/. EXHAUST HOOD -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –
PROVIDE POWER AND GAS AS REQUIRED -30”MIN. VERTICAL CLEARANCE TO ANY
COMBUSTIBLE MATERIAL ABV. COOKING TOP (CMC 920.3.2) –EXHAUST HOOD TO HAVE
EXHAUST RATE OF MIN. 100 CFM AND VENT TO OUTDOOR , HOOD DUCTS TO BE OF
METAL WITH SMOOTH INTERIOR FINISH PER SECTION 504.3 OF CMC
KITCHEN/BAR SINK -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –SINK TO COMPLY
W/. REQUIREMENT OF SECTION 420.0 OF CPC AND HAVE A MAX FLOW RATE OF 1.8 GPM
@ 60 PSI PER SECTION 4.303.1 OF CALGREEN –TRAP AND VENT FOR ISLAND SINK AND
SIMILAR EQUIPMENT SHALL BE PER SECTION 909.0 OF CPC
VANITY SINK -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –
LAVATORY TO HAVE 24”MIN. CLEAR SPACE IN FRONT OF IT.(CPC 402.5)
W/. MAXIMUM FLOW RATE OF 1.2 GPM @ 60 PSI AND MIN. FLOW RATE OF
0.8 GPM @ 20 PSI PER SECTION 4.303.1 OF CALGREEN
WASHER (W) / DRYER (D) / STACKED (W/D)-AS SELECTED PER I.D., VERIFY W/. I.D. &
OWNER –PROVIDE POWER , GAS, WATER SUPPLY & DRAINAGE AS REQUIRED -THE
CLOTHES DRYERS VENT SHALL BE OF A RIGID METALLIC MATERIAL AND HAVE A
BACKDRAFT DAMPER (CMC 504.4) AND SHALL NOT EXCEED 14-FEET IN OVERALL LENGTH
WITH MAX. OF TWO (2) 90-DEGREE ELBOW, SUBTRACT 2-FEET FOR EACH ADDITIONAL 90-
DEGREE ELBOW. SEE WASHER & DRYER NOTES, REF. T-1.1.
REFRIGERATOR (REF) / FREEZER (FRZ) -AS SELECTED PER I.D., VERIFY W/. I.D. &
OWNER –PROVIDE POWER AND WATER SUPPLY AS REQUIRED
BUILT-IN APPLIANCE / DISHWASHER (DW) / TRASH COMPACTOR (TR)-AS SELECTED PER
I.D., VERIFY W/. I.D. & OWNER –PROVIDE POWER , WATER SUPPLY & DRAINAGE PIPE AS
REQUIRED
TOILET -WATER CLOSET SHALL BE IN COMPLIANCE OF SECTION 411.0 OF CPC AND HAS
MAX EFFECTIVE FLUSH RATE OF 1.28 GAL. PER FLUSH (CPC 411.2). WATER CLOSETS
CLR. TO BE 24”IN FRONT AND 15”FROM ITS CENTER TO ANY SIDE WALL OR
OBSTRUCTION. (CPC 402.5 & CRC R307) –REF. CALGREEN NOTES ON T SHTS. FOR MAX
FLOW RATE
CASEWORK, TALL CABINET -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER
CASEWORK, BASE CABINET W/. COUNTERTOP -AS SELECTED PER I.D., VERIFY W/. I.D. &
OWNER
CASEWORK, UPPER CABINET/SHELVES -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER
BUILT-IN CLOSET -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER
FIREPLACE -FACTORY-BUILT DIRECT VENT GAS FIREPLACE W/. SEALED COMBUSTION
(CALGREEN 4.503) -FACTORY-BUILT FIREPLACES, CHIMNEYS AND ALL OF THEIR
COMPONENTS SHALL BE LISTED AND INSTALLED IN ACCORDANCE WITH THEIR LISTING
AND MANUFACTURER'S INSTALLATION INSTRUCTIONS. (CRC R1004.1)
ELEVATOR -PRIVATE RESIDENCE ELEVATOR IN COMPLIANCE W/. ASME A17.1/CSA B44
AS SELECTED PER PLANS, VERIFY W/. OWNER –PROVIDE POWER AS REQ'D. (CRC 321.1)
A/C CONDENSER / HEAT PUMP -TO BE IN COMPLIANCE OF SECTION 307.3 OF CMC AS
SELECTED, VERIFY W/. OWNER -SIZE TBD, SEE T-24 ENERGY REPORT FOR MORE INFO –
PROVIDE POWER AND SOUND DAMPENING PAD AS REQ’D. –INSTALL AND MAINTAIN
REQUIRED CLEARANCES PER MFGR. INSTRUCTION
FAU -PROVIDE GAS S.O., POWER, AND VENTING AS REQ'D. BY MFG'R. –INSTALL PER
MFGR. INSTRUCTION
ROOF/DECK DRAIN -PER CHAPTER 11 OF CPC -SIZE THE DRAIN AND PIPING PER TABLE
1103.1 AND 1103.2 OF CPC –ROOF DRAIN SHALL HAVE DOMED STRAINER (CPC 1102.2) –
REF. DETAIL 11/AD-1.0
OVERFLOW OR EMERGENCY DRAIN -PER CHAPTER 11 OF CPC -COPPER OR EQ., INSTALL
PER MFGR. INSTRUC., SLOPED TOWARD IN-WALL DRAIN INLETS –SLOPE AND SIZE PER
TABLE 1103.3 OF CPC –REF. DTL. 11/AD-1.0
UP
20R@7 1/2"STAIRS -MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE AN ILLUMINATION LEVEL OF NOT
LESS THAN 1 FOOT CANDLE AS MEASURED AT THE CENTER OF TREADS AND
LANDING WITH ARTIFICIAL LIGHTING (R303.7) -REF. DTL. 3/AD-1
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
KEYNOTESB
ANNOTATION LEGENDA
BRANDON ARCHITECTS
01/20/2023
FIRST LEVEL FLOOR
PLAN
MI
L
L
E
R
R
E
S
I
D
E
N
C
E
MR. & MRS. MATTHEW MILLER
22 BAY ISLAND,
NEWPORT BEACH, CA 92661
P: 949.235.9286
millermg123@gmail.com
CDP
22 BAY ISLAND
NEWPORT BEACH, CA 92661
A-2.0
TBD
BRIAN JOWETT
1/4" = 1'-0"1 FIRST LEVEL FLOOR PLAN
1 BOUNDARY LINE
2 SIDE YARD SETBACK
3 FRONT YARD SETBACK
4 REAR YARD SETBACK
5 RECESSED MAIN SERVICE PANEL, 400 AMP MAX. (MAINTAIN 36" CLEAR FROM FACE OF PANEL TO ANY OBSTRUCTION)
6 EASEMENT LINE
7 PROVIDE FLOOR DRAIN IN LAUNDRY ROOM
8 ENCLOSED USEABLE SPACE UNDER STAIRWAY USE 5/8" TYPE 'X' GYP. BD. FINISH TYP. (1/2" MIN.) (CRC R302.7)
9 1-1/2" MAX. STEP AT OUT SWING DOORS (R311.3.1)
10 DEPRESS STRUCTURE FOR FLUSH SHOWER CONDITION - COORD. WITH I.D. & GENERAL CONTRACTOR, REF. STRUCT. DWGS.
11 GARAGE DOOR - RATED, 1-3/8" SOLID CORE, SELF-CLOSING AND SELF-LATCHING. REF. DOOR SCHEDULE
12 WATER HEATER - TANK-LESS - SIZE PER T-24 REPORT REF. DTL. 1/AD-1 - VERIFY SIZE REQ'D. W/. MFG. (PROVIDE ADEQUATE
N.G. CONN.)
13 RANGE - VERIFY APPLIANCE W/. OWNER - PROVIDE HOOD CAPABLE OF 100 CFM MIN. (VERIFY W/. MFG.) - VENT TO OUTDOOR
AIR
14 KITCHEN EXHAUST HOOD TO VENT TO EXT. - PROVIDE MIN. RATE OF 100 CFM - INSTALL & PROVIDE POWER PER MFG.
INSTRUCTION
15 WINDOW TO MEET EGRESS REQUIREMENTS - REF. DOOR AND WINDOW NOTES, SHT. A-7.0
16 DOWNSPOUT - ALUMINUM W/. KYNAR FINISH OR EQUIV. - AS SEL. (ARCH. TO APPROVE)
17 KITCHEN ISLAND - BASE CABINET, COUNTER, AND APPLIANCES PER I.D - VERIFY SIZE W/. I.D. & OWNER
18 DRAIN LINE - IN WALL/FROM DECK/ROOF ABV. PROVIDE DRAIN SWEEP(ELBOW JOINT) PER CIVIL DWG'S., PRIOR TO POURING
SLAB. VERIFY LOC'N. W/. SITE DRAINAGE & COORD. W/. CIVIL
19 FIREPLACE - PREFABRICATED, GAS ONLY, 'FLARE - FF-50H ' [DTL. 22/AD-1] (FACTORY BUILT FIREPLACES, CHIMNEYS, AND ALL
OF THEIR COMPONENTS SHALL BE LISTED AND INSTALLED IN ACCORDANCE W/. THEIR LISTING AND MFG'R. INSTALLATION
INSTRUCTIONS. GASEOUS FUEL BURNING PAN MUST BE PERMANENTLY ANCHORED TO THE FIREBOX. FIREPLACE MUST
COMPLY W/. THE CALIFORNIA ENERGY STANDARDS MANDATORY MEASURES.)
NO. REVISION DATE
UP
DN
A-4.1
A-4.0
A-4.03A-4.1
1
1
2
1
A-5.0
1
A-5.0
3
A-5.0
3
A-5.0
2
A-5.0
2
A-5.0
BEDROOM 2
BEDROOM 3
W.I.C.
BATH 4
STUDY
PRIMARY BEDROOM
PRIMARY CLOSET
W/C
BUNK ROOMBATH 3
BATH 2
PRIMARY BATH
BALCONY 2
BALCONY 3
PRIMARY BALCONY
30" MIN. CLR.
3' - 0"
F.Y.S.B.
4' - 0"
R.Y.S.B.
18' - 0"
S.Y.S.B.
8'
-
0
"
S.Y.S.B.
5'
-
0
"
SLOPE
2% MIN.
SLOPE
2% MIN.
SLOPE
2% MIN.
1
S.Y.S.B.
6'
-
0
"
S.Y.S.B.
6'
-
0
"
22.26' F.F.
22.26' F.F.
CLR.
30" MIN.
CLR.
30" MIN.
CLR.
30" MIN.
1
1
1
2
34
5
3
4
4
6
6
7
8
8
9
8
8
8
8 9
6
7
8
8
9
7
24
23
25
26
27 15
14
19
16
18
3031
24 23
2221
20
18
25
23
24
23
24
8
10
10
10
10
11
11
11
12
CLR.
30" MIN.
81314
14
15
16
2526
28 2729
15 16 17
19
17
2
22
2
1
20
21
30" MIN. CLR.
3' - 0"
30" MIN. CLR.
3'
-
0
"
30" MIN. CLR.
3'
-
4
3
/
4
"
12
13
MAX
5' - 0"
MAX
4' - 0"
ROOM TAGROOM NAME
1
A-5.0
1 1
?
1
1
A-4.0
1
1 1
1
ELEVATION / SECTION INDICATOR
AD-1.0
1 CALL-OUT TAG
10.00'SPOT ELEVATION
KEYNOTE TAG
REVISION TAG
DOOR / WINDOW / WINDOW WALL TAG
FIRE RATED CEILING ASS'Y -REF. DTLS. 8/AD-1.0
1-HR RATED INT CONDITION -REF. DTLS. 8/AD-1.0
1-HR RATED EXT CONDITION -REF. DTLS. 12/AD-1.0
STRUCTURAL STEEL COLUMN PER STRUCT., REF. STRUTC.
DWGS, -PAINT AND SEAL AS REQUIRED –ARCH. TO APPV.
COLOR FOR EXPOSED STEEL COLUMNS
STRUCTURAL WOOD POST/COLUMN COLUMN -PER STRUCT., REF. STRUTC. DWGS, -
PAINT, STAIN AND SEAL AS REQUIRED –ARCH. TO APPV. PAINT COLOR FOR EXPOSED
WOOD POST/COLUMN, IF TO BE STAINED PROVIDE STAINED SAMPLE FOR ARCH,
APPROVAL
DOORS -AS SPECIFIED, SEE WINDOW SCHEDULE AND GENERAL NOTES ON SHEET A-7.0 -
SHGC & U-FCTOR PER T-24 ENERGY REPORT – SEE SHEET AD-2.0 FOR JAMB, HEAD AND
THRESHOLD DETAILS, PROVIDE FLASHING AND WATERPROOFING AT DOOR OPENING PER
THE DOOR MFGR. INSTRUCTION AND/OR FLASHING MFGR. INSTRUCTION PER SECTIONS
R609.1 & R703.4 OF CRC
WINDOW -AS SPECIFIED, SEE WINDOW SCHEDULE AND GENERAL NOTES ON
SHEET A-7.0 -SHGC & U-FCTOR PER T-24 ENERGY REPORT – SEE SHEET
AD-2.0 FOR JAMB, HEAD AND SILL DETAILS, PROVIDE FLASHING AND
WATERPROOFING AT WINDOW OPENING PER THE WINDOW MFGR.
INSTRUCTION AND/OR FLASHING MFGR. INSTRUCTION PER SECTIONS R609.1
& R703.4 OF CRC
KITCHEN RANGE W/. EXHAUST HOOD -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –
PROVIDE POWER AND GAS AS REQUIRED -30”MIN. VERTICAL CLEARANCE TO ANY
COMBUSTIBLE MATERIAL ABV. COOKING TOP (CMC 920.3.2) –EXHAUST HOOD TO HAVE
EXHAUST RATE OF MIN. 100 CFM AND VENT TO OUTDOOR , HOOD DUCTS TO BE OF
METAL WITH SMOOTH INTERIOR FINISH PER SECTION 504.3 OF CMC
KITCHEN/BAR SINK -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –SINK TO COMPLY
W/. REQUIREMENT OF SECTION 420.0 OF CPC AND HAVE A MAX FLOW RATE OF 1.8 GPM
@ 60 PSI PER SECTION 4.303.1 OF CALGREEN –TRAP AND VENT FOR ISLAND SINK AND
SIMILAR EQUIPMENT SHALL BE PER SECTION 909.0 OF CPC
VANITY SINK -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –
LAVATORY TO HAVE 24”MIN. CLEAR SPACE IN FRONT OF IT.(CPC 402.5)
W/. MAXIMUM FLOW RATE OF 1.2 GPM @ 60 PSI AND MIN. FLOW RATE OF
0.8 GPM @ 20 PSI PER SECTION 4.303.1 OF CALGREEN
WASHER (W) / DRYER (D) / STACKED (W/D)-AS SELECTED PER I.D., VERIFY W/. I.D. &
OWNER –PROVIDE POWER , GAS, WATER SUPPLY & DRAINAGE AS REQUIRED -THE
CLOTHES DRYERS VENT SHALL BE OF A RIGID METALLIC MATERIAL AND HAVE A
BACKDRAFT DAMPER (CMC 504.4) AND SHALL NOT EXCEED 14-FEET IN OVERALL LENGTH
WITH MAX. OF TWO (2) 90-DEGREE ELBOW, SUBTRACT 2-FEET FOR EACH ADDITIONAL 90-
DEGREE ELBOW. SEE WASHER & DRYER NOTES, REF. T-1.1.
REFRIGERATOR (REF) / FREEZER (FRZ) -AS SELECTED PER I.D., VERIFY W/. I.D. &
OWNER –PROVIDE POWER AND WATER SUPPLY AS REQUIRED
BUILT-IN APPLIANCE / DISHWASHER (DW) / TRASH COMPACTOR (TR)-AS SELECTED PER
I.D., VERIFY W/. I.D. & OWNER –PROVIDE POWER , WATER SUPPLY & DRAINAGE PIPE AS
REQUIRED
TOILET -WATER CLOSET SHALL BE IN COMPLIANCE OF SECTION 411.0 OF CPC AND HAS
MAX EFFECTIVE FLUSH RATE OF 1.28 GAL. PER FLUSH (CPC 411.2). WATER CLOSETS
CLR. TO BE 24”IN FRONT AND 15”FROM ITS CENTER TO ANY SIDE WALL OR
OBSTRUCTION. (CPC 402.5 & CRC R307) –REF. CALGREEN NOTES ON T SHTS. FOR MAX
FLOW RATE
CASEWORK, TALL CABINET -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER
CASEWORK, BASE CABINET W/. COUNTERTOP -AS SELECTED PER I.D., VERIFY W/. I.D. &
OWNER
CASEWORK, UPPER CABINET/SHELVES -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER
BUILT-IN CLOSET -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER
FIREPLACE -FACTORY-BUILT DIRECT VENT GAS FIREPLACE W/. SEALED COMBUSTION
(CALGREEN 4.503) -FACTORY-BUILT FIREPLACES, CHIMNEYS AND ALL OF THEIR
COMPONENTS SHALL BE LISTED AND INSTALLED IN ACCORDANCE WITH THEIR LISTING
AND MANUFACTURER'S INSTALLATION INSTRUCTIONS. (CRC R1004.1)
ELEVATOR -PRIVATE RESIDENCE ELEVATOR IN COMPLIANCE W/. ASME A17.1/CSA B44
AS SELECTED PER PLANS, VERIFY W/. OWNER –PROVIDE POWER AS REQ'D. (CRC 321.1)
A/C CONDENSER / HEAT PUMP -TO BE IN COMPLIANCE OF SECTION 307.3 OF CMC AS
SELECTED, VERIFY W/. OWNER -SIZE TBD, SEE T-24 ENERGY REPORT FOR MORE INFO –
PROVIDE POWER AND SOUND DAMPENING PAD AS REQ’D. –INSTALL AND MAINTAIN
REQUIRED CLEARANCES PER MFGR. INSTRUCTION
FAU -PROVIDE GAS S.O., POWER, AND VENTING AS REQ'D. BY MFG'R. –INSTALL PER
MFGR. INSTRUCTION
ROOF/DECK DRAIN -PER CHAPTER 11 OF CPC -SIZE THE DRAIN AND PIPING PER TABLE
1103.1 AND 1103.2 OF CPC –ROOF DRAIN SHALL HAVE DOMED STRAINER (CPC 1102.2) –
REF. DETAIL 11/AD-1.0
OVERFLOW OR EMERGENCY DRAIN -PER CHAPTER 11 OF CPC -COPPER OR EQ., INSTALL
PER MFGR. INSTRUC., SLOPED TOWARD IN-WALL DRAIN INLETS –SLOPE AND SIZE PER
TABLE 1103.3 OF CPC –REF. DTL. 11/AD-1.0
UP
20R@7 1/2"STAIRS -MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE AN ILLUMINATION LEVEL OF NOT
LESS THAN 1 FOOT CANDLE AS MEASURED AT THE CENTER OF TREADS AND
LANDING WITH ARTIFICIAL LIGHTING (R303.7) -REF. DTL. 3/AD-1
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
KEYNOTESB
ANNOTATION LEGENDA
BRANDON ARCHITECTS
01/20/2023
SECOND LEVEL
FLOOR PLAN
MI
L
L
E
R
R
E
S
I
D
E
N
C
E
MR. & MRS. MATTHEW MILLER
22 BAY ISLAND,
NEWPORT BEACH, CA 92661
P: 949.235.9286
millermg123@gmail.com
CDP
22 BAY ISLAND
NEWPORT BEACH, CA 92661
A-2.1
TBD
BRIAN JOWETT
1/4" = 1'-0"1 SECOND LEVEL FLOOR PLAN
1 BOUNDARY LINE
2 FRONT YARD SETBACK
3 EASEMENT LINE
4 SIDE YARD SETBACK
5 REAR YARD SETBACK
6 EXTERIOR GUARDRAIL, WROUGHT IRON - MIN. 42" HEIGHT - 4" MAX. SPHERE OPENING, REF. DTL. 4/AD-1
7 DECK DRAIN - SLOPE 2% MIN. - REF. DTL. 11/AD-1
8 DOWNSPOUT - ALUMINUM W/. KYNAR FINISH OR EQUIV. - AS SEL. (ARCH. TO APPROVE)
9 WINDOW TO MEET EGRESS REQUIREMENTS - REF. DOOR AND WINDOW NOTES, SHT. A-7.0
10 DEPRESSED SLAB FOR ELEVATOR - 12". COORD. WITH ELEVATOR MFG. & G.C., REF. STRUCT. DRAWINGS
11 BISON DECKING SYSTEM OVER WESTCOAT ALX WATERPROOFING SYSTEM PER ICC# EST - 2201, REF. MAT. SCHED. A/A-4.0.
12 CEILING FRAMING - REF. STRUCT.
13 GUTTER - ALUMINUM W/. KYNAR FINISH, SHAPE AS SEL. - PROVIDE SHOP DWGS. TO ARCH.
14 DRAIN LINE - IN WALL/FROM DECK/ROOF ABV. PROVIDE DRAIN SWEEP(ELBOW JOINT) PER CIVIL DWG'S., PRIOR TO POURING
SLAB. VERIFY LOC'N. W/. SITE DRAINAGE & COORD. W/. CIVIL
15 JULIET WROUGHT IRON BALCONY, ARCH. TO APPROVE. REF. STRUCT FOR CONNECTION
16 FIREPLACE - PREFABRICATED, GAS ONLY, 'FLARE - FF-50H ' [DTL. 22/AD-1] (FACTORY BUILT FIREPLACES, CHIMNEYS, AND ALL
OF THEIR COMPONENTS SHALL BE LISTED AND INSTALLED IN ACCORDANCE W/. THEIR LISTING AND MFG'R. INSTALLATION
INSTRUCTIONS. GASEOUS FUEL BURNING PAN MUST BE PERMANENTLY ANCHORED TO THE FIREBOX. FIREPLACE MUST
COMPLY W/. THE CALIFORNIA ENERGY STANDARDS MANDATORY MEASURES.)
NO. REVISION DATE
DN
ROOM TAGROOM NAME
1
A-5.0
1 1
?
1
1
A-4.0
1
1 1
1
ELEVATION / SECTION INDICATOR
AD-1.0
1 CALL-OUT TAG
10.00'SPOT ELEVATION
KEYNOTE TAG
REVISION TAG
DOOR / WINDOW / WINDOW WALL TAG
FIRE RATED CEILING ASS'Y -REF. DTLS. 8/AD-1.0
1-HR RATED INT CONDITION -REF. DTLS. 8/AD-1.0
1-HR RATED EXT CONDITION -REF. DTLS. 12/AD-1.0
STRUCTURAL STEEL COLUMN PER STRUCT., REF. STRUTC.
DWGS, -PAINT AND SEAL AS REQUIRED –ARCH. TO APPV.
COLOR FOR EXPOSED STEEL COLUMNS
STRUCTURAL WOOD POST/COLUMN COLUMN -PER STRUCT., REF. STRUTC. DWGS, -
PAINT, STAIN AND SEAL AS REQUIRED –ARCH. TO APPV. PAINT COLOR FOR EXPOSED
WOOD POST/COLUMN, IF TO BE STAINED PROVIDE STAINED SAMPLE FOR ARCH,
APPROVAL
DOORS -AS SPECIFIED, SEE WINDOW SCHEDULE AND GENERAL NOTES ON SHEET A-7.0 -
SHGC & U-FCTOR PER T-24 ENERGY REPORT – SEE SHEET AD-2.0 FOR JAMB, HEAD AND
THRESHOLD DETAILS, PROVIDE FLASHING AND WATERPROOFING AT DOOR OPENING PER
THE DOOR MFGR. INSTRUCTION AND/OR FLASHING MFGR. INSTRUCTION PER SECTIONS
R609.1 & R703.4 OF CRC
WINDOW -AS SPECIFIED, SEE WINDOW SCHEDULE AND GENERAL NOTES ON
SHEET A-7.0 -SHGC & U-FCTOR PER T-24 ENERGY REPORT – SEE SHEET
AD-2.0 FOR JAMB, HEAD AND SILL DETAILS, PROVIDE FLASHING AND
WATERPROOFING AT WINDOW OPENING PER THE WINDOW MFGR.
INSTRUCTION AND/OR FLASHING MFGR. INSTRUCTION PER SECTIONS R609.1
& R703.4 OF CRC
KITCHEN RANGE W/. EXHAUST HOOD -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –
PROVIDE POWER AND GAS AS REQUIRED -30”MIN. VERTICAL CLEARANCE TO ANY
COMBUSTIBLE MATERIAL ABV. COOKING TOP (CMC 920.3.2) –EXHAUST HOOD TO HAVE
EXHAUST RATE OF MIN. 100 CFM AND VENT TO OUTDOOR , HOOD DUCTS TO BE OF
METAL WITH SMOOTH INTERIOR FINISH PER SECTION 504.3 OF CMC
KITCHEN/BAR SINK -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –SINK TO COMPLY
W/. REQUIREMENT OF SECTION 420.0 OF CPC AND HAVE A MAX FLOW RATE OF 1.8 GPM
@ 60 PSI PER SECTION 4.303.1 OF CALGREEN –TRAP AND VENT FOR ISLAND SINK AND
SIMILAR EQUIPMENT SHALL BE PER SECTION 909.0 OF CPC
VANITY SINK -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –
LAVATORY TO HAVE 24”MIN. CLEAR SPACE IN FRONT OF IT.(CPC 402.5)
W/. MAXIMUM FLOW RATE OF 1.2 GPM @ 60 PSI AND MIN. FLOW RATE OF
0.8 GPM @ 20 PSI PER SECTION 4.303.1 OF CALGREEN
WASHER (W) / DRYER (D) / STACKED (W/D)-AS SELECTED PER I.D., VERIFY W/. I.D. &
OWNER –PROVIDE POWER , GAS, WATER SUPPLY & DRAINAGE AS REQUIRED -THE
CLOTHES DRYERS VENT SHALL BE OF A RIGID METALLIC MATERIAL AND HAVE A
BACKDRAFT DAMPER (CMC 504.4) AND SHALL NOT EXCEED 14-FEET IN OVERALL LENGTH
WITH MAX. OF TWO (2) 90-DEGREE ELBOW, SUBTRACT 2-FEET FOR EACH ADDITIONAL 90-
DEGREE ELBOW. SEE WASHER & DRYER NOTES, REF. T-1.1.
REFRIGERATOR (REF) / FREEZER (FRZ) -AS SELECTED PER I.D., VERIFY W/. I.D. &
OWNER –PROVIDE POWER AND WATER SUPPLY AS REQUIRED
BUILT-IN APPLIANCE / DISHWASHER (DW) / TRASH COMPACTOR (TR)-AS SELECTED PER
I.D., VERIFY W/. I.D. & OWNER –PROVIDE POWER , WATER SUPPLY & DRAINAGE PIPE AS
REQUIRED
TOILET -WATER CLOSET SHALL BE IN COMPLIANCE OF SECTION 411.0 OF CPC AND HAS
MAX EFFECTIVE FLUSH RATE OF 1.28 GAL. PER FLUSH (CPC 411.2). WATER CLOSETS
CLR. TO BE 24”IN FRONT AND 15”FROM ITS CENTER TO ANY SIDE WALL OR
OBSTRUCTION. (CPC 402.5 & CRC R307) –REF. CALGREEN NOTES ON T SHTS. FOR MAX
FLOW RATE
CASEWORK, TALL CABINET -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER
CASEWORK, BASE CABINET W/. COUNTERTOP -AS SELECTED PER I.D., VERIFY W/. I.D. &
OWNER
CASEWORK, UPPER CABINET/SHELVES -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER
BUILT-IN CLOSET -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER
FIREPLACE -FACTORY-BUILT DIRECT VENT GAS FIREPLACE W/. SEALED COMBUSTION
(CALGREEN 4.503) -FACTORY-BUILT FIREPLACES, CHIMNEYS AND ALL OF THEIR
COMPONENTS SHALL BE LISTED AND INSTALLED IN ACCORDANCE WITH THEIR LISTING
AND MANUFACTURER'S INSTALLATION INSTRUCTIONS. (CRC R1004.1)
ELEVATOR -PRIVATE RESIDENCE ELEVATOR IN COMPLIANCE W/. ASME A17.1/CSA B44
AS SELECTED PER PLANS, VERIFY W/. OWNER –PROVIDE POWER AS REQ'D. (CRC 321.1)
A/C CONDENSER / HEAT PUMP -TO BE IN COMPLIANCE OF SECTION 307.3 OF CMC AS
SELECTED, VERIFY W/. OWNER -SIZE TBD, SEE T-24 ENERGY REPORT FOR MORE INFO –
PROVIDE POWER AND SOUND DAMPENING PAD AS REQ’D. –INSTALL AND MAINTAIN
REQUIRED CLEARANCES PER MFGR. INSTRUCTION
FAU -PROVIDE GAS S.O., POWER, AND VENTING AS REQ'D. BY MFG'R. –INSTALL PER
MFGR. INSTRUCTION
ROOF/DECK DRAIN -PER CHAPTER 11 OF CPC -SIZE THE DRAIN AND PIPING PER TABLE
1103.1 AND 1103.2 OF CPC –ROOF DRAIN SHALL HAVE DOMED STRAINER (CPC 1102.2) –
REF. DETAIL 11/AD-1.0
OVERFLOW OR EMERGENCY DRAIN -PER CHAPTER 11 OF CPC -COPPER OR EQ., INSTALL
PER MFGR. INSTRUC., SLOPED TOWARD IN-WALL DRAIN INLETS –SLOPE AND SIZE PER
TABLE 1103.3 OF CPC –REF. DTL. 11/AD-1.0
UP
20R@7 1/2"STAIRS -MAX. 7.75" RISE, MIN. 10" RUN, PROVIDE AN ILLUMINATION LEVEL OF NOT
LESS THAN 1 FOOT CANDLE AS MEASURED AT THE CENTER OF TREADS AND
LANDING WITH ARTIFICIAL LIGHTING (R303.7) -REF. DTL. 3/AD-1
A-4.1
A-4.0
A-4.03A-4.1
1
1
2
1
A-5.0
1
A-5.0
3
A-5.0
3
A-5.0
2
A-5.0
2
A-5.0
PWD. 2
MECH. WELL
MECH.
ROOF DECK
F.Y.S.B.
4' - 0"
THIRD FLOOR STRUCTURE SETBACK
15' - 0"
THIRD FLOOR STRUCTURE SETBACK
15' - 0"
R.Y.S.B.
18' - 0"
4'
-
0
"
S.Y.S.B.
8'
-
0
"
4'
-
0
"
S.Y.S.B.
5'
-
0
"
SLOPE 2% MIN.SLOPE
2% MIN.
FLAT ROOF SETBACK
8' - 0"
TH
I
R
D
F
L
O
O
R
ST
R
U
C
T
U
R
E
SE
T
B
A
C
K
4'
-
0
"
4'
-
0
"
FLAT ROOF SETBACK
8'
-
0
"
FLAT ROOF SETBACK
8' - 0"
FLAT ROOF SETBACK
8'
-
0
"
FLAT ROOF SETBACK
8'
-
0
"
TH
I
R
D
F
L
O
O
R
ST
R
U
C
T
U
R
E
SE
T
B
A
C
K
TH
I
R
D
F
L
O
O
R
ST
R
U
C
T
U
R
E
SE
T
B
A
C
K
S.Y.S.B.
6'
-
0
"
S.Y.S.B.
6'
-
0
"
TH
I
R
D
F
L
O
O
R
ST
R
U
C
T
U
R
E
SE
T
B
A
C
K
32.52' F.F.
1
1
1
1
2
3 4
5
3
4
29
28
6
6
6
6
6
6
6
32.22' T.O.S.
FLAT ROOF SETBACK
8'
-
0
"
6
6
6
66
7
830
32 3433 35 36
37
9
9
10
10 11 12
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
KEYNOTESB
ANNOTATION LEGENDA
BRANDON ARCHITECTS
01/20/2023
THIRD LEVEL FLOOR
PLAN
MI
L
L
E
R
R
E
S
I
D
E
N
C
E
MR. & MRS. MATTHEW MILLER
22 BAY ISLAND,
NEWPORT BEACH, CA 92661
P: 949.235.9286
millermg123@gmail.com
CDP
22 BAY ISLAND
NEWPORT BEACH, CA 92661
A-2.2
TBD
BRIAN JOWETT
1 BOUNDARY LINE
2 REAR YARD SETBACK
3 EASEMENT LINE
4 SIDE YARD SETBACK
5 FRONT YARD SETBACK
6 DOWNSPOUT - ALUMINUM W/. KYNAR FINISH OR EQUIV. - AS SEL. (ARCH. TO APPROVE)
7 BISON DECKING SYSTEM OVER WESTCOAT ALX WATERPROOFING SYSTEM PER ICC# EST - 2201, REF. MAT. SCHED. A/A-4.0.
8 WESTCOAT ALX WALKING DECK AND ROOF COVERING SYSTEM RATED CLASS' A' ASSEMBLY PER ICC# ESR -2201, REF. MAT.
SCHED. A/A-4.0.
9 FABRIC AWNING AS SELECTED, ARCH. TO APPROVE
10 DECK DRAIN - SLOPE 2% MIN. - REF. DTL. 11/AD-1
11 BBQ - VERIFY APPLIANCE W/. OWNER
12 REFRIGERATOR - UNDER-COUNTER, PER I.D. & OWNER
1/4" = 1'-0"1 THIRD LEVEL FLOOR PLAN
NO. REVISION DATE
DN
UP
DIMENSION NOTE:
ALL DIMENSIONS ARE TO FACE OF SHEATHING (EXT. WALLS) OR FACE OF STRUCTURE (F.O.S.) TYP. U.N.O. ROUNDED TO THE
NEAREST 1/8" AND INTERIOR PARTITIONS ARE DIMENSIONED FROM FACE OF STRUCTURE TO FACE OF STRUCTURE (F.O.S.) U.N.O. -
CONTACT ARCHITECT IN WRITING FOR ANY CLARIFICATION OF NOTED DIMENSIONS, DO NOT SCALE PLANS.
ROUGH FRAMING:
ALL EXTERIOR WALLS TO BE FRAMED W/. 2X6 STUD MIN. U.N.O.
USE 2X6 MINIMUM STUDS FOR PLUMBING WALLS
SECOND AND THIRD FLOOR PLYWOOD TO BE 1-1/8"
ENTIRE EXTERIOR TO BE SHEATHED WITH 1/2" PLYWOOD
DOORS AND WINDOWS WILL TYPICALLY BE RECESSED FROM EXTERIOR WALL PLANE. VERIFY ALL ROUGH OPENING DIMENSIONS
WITH DOOR AND WINDOW MFGR. ROUGH OPENING MAY NEED TO BE OVERSIZED TO ACCOUNT FOR ADDITIONAL FRAMING. SEE
SHT. AD-2.0 FOR TYP. RECESSED CONDITIONS.
GARAGE FLOOR:
GARAGE FLOOR SURFACES SHALL BE OF APPROVED NONCOMBUSTIBLE MATERIAL.THE AREA OF FLOOR USED FOR PARKING OF
AUTOMOBILES OR OTHER VEHICLES SHALL BE SLOPED TO FACILITATE THE MOVEMENT OF LIQUIDS TO A DRAIN OR TOWARD THE
MAIN VEHICLE ENTRY DOORWAY. (R309.1)
PLUMBING:
1. SUPPORT ALL WALL-HUNG FIXTURES WITH METAL SUPPORTING MEMBERS TO PREVENT ANY STRAIN TRANSMISSION TO THE
CONNECTIONS. FRAMING AFFIXED SUPPORTS FOR OFF-THE-FLOOR WATER CLOSETS WITH CONCEALED TANKS SHALL COMPLY
WITH ASME A112.6.2. SECURE FLUSH TANK AND SIMILAR APPURTENANCES WITH APPROVED NON-CORROSIVE SCREW OR BOLTS.
(CPC 402.5)
2. THE NET AREA OF THE SHOWER ENCLOSURE SHALL BE 1,024 SQ. INCHES (7.1 SQ. FT.) OR MORE IN THE CLEAR FLOOR AREA,
AND SHALL ALSO BE CAPABLE OF ENCOMPASSING A 30-INCH DIAMETER CIRCLE. (CPC 408.6)
3. THE WATER HEATER BURNER AND BURNER-IGNITION DEVICE TO BE AT LEAST 18-INCHES ABOVE THE FLOOR, IF LOCATED IN A
GARAGE AND IN ADJACENT SPACES THAT OPEN TO THE GARAGE. FOR WATER HEATER IN THE GARAGE OR OTHER AREAS SUBJECT
TO MECHANICAL DAMAGE PROVIDE A PROTECTIVE BARRIER OR ELEVATE THE APPLIANCE TO BE OUT OF THE NORMAL PATH OF
THE VEHICLE. (CPC 507.13)
4. ANCHOR OR STRAP THE WATER HEATER(S) TO RESIST HORIZ. DISPLACEMENT DUE TO THE EARTHQUAKE. STRAPPING SHOULD
BE AT THE UPPER AND LOWER ONE THIRD (1/3) POINTS OF THE APPLIANCE HEIGHT. MAINTAIN A MIN. 4-INCHES ABOVE THE
CONTROLS WITH STRAPPING AT LOWER POINT.
WOOD OR WOODBASED PRODUCTS NOTE:
WOOD OR WOODBASE PRODUCT SHALL BE OF A NATURAL DURABLE OR PRESERVATIVE-TREADED WOOD IN ACCORDANCE WITH
AWPA U1 FOR THE SPECIES, PRODUCT, PRESERVATIVE AND END USE IN THE FOLLOWING LOCATIONS:
1. WOOD JOISTS OR THE BOTTOM OF A WOOD STRUCTURAL FLOOR WHEN CLOSER THAN 18 INCHES (457 MM) OR WOOD GIRDERS
WHEN CLOSER THAN 12 INCHES (305 MM) TO THE EXPOSED GROUND IN CRAWL SPACES OR UNEXCAVATED AREA LOCATED
WITHIN THE PERIPHERY OF THE BUILDING FOUNDATION.
2. WOOD FRAMING MEMBERS THAT REST ON CONCRETE OR MASONRY EXTERIOR FOUNDATION WALLS AND ARE LESS THAN 8
INCHES (203 MM) FROM THE EXPOSED GROUND.
3. SILLS AND SLEEPERS ON A CONCRETE OR MASONRY SLAB THAT IS IN DIRECT CONTACT WITH THE GROUND UNLESS
SEPARATED FROM SUCH SLAB BY AN IMPERVIOUS MOISTURE BARRIER.
4. THE ENDS OF WOOD GIRDERS ENTERING EXTERIOR MASONRY OR CONCRETE WALLS HAVING CLEARANCES OF LESS THAN 1/2
INCH (12.7 MM) ON TOPS, SIDES AND ENDS.
5. WOOD SIDING, SHEATHING AND WALL FRAMING ON THE EXTERIOR OF A BUILDING HAVING A CLEARANCE OF LESS THAN 6
INCHES (152 MM) FROM THE GROUND OR LESS THAN 2 INCHES (51 MM) MEASURED VERTICALLY FROM CONCRETE STEPS,
PORCH SLABS, PATIO SLABS AND SIMILAR HORIZONTAL SURFACES EXPOSED TO THE WEATHER.
6. WOOD STRUCTURAL MEMBERS SUPPORTING MOISTURE-PERMEABLE FLOORS OR ROOFS THAT ARE EXPOSED TO THE
WEATHER, SUCH AS CONCRETE OR MASONRY SLABS, UNLESS SEPARATED FROM SUCH FLOORS OR ROOFS BY AN IMPERVIOUS
MOISTURE BARRIER.
7. WOOD FURRING STRIPS OR OTHER WOOD FRAMING MEMBERS ATTACHED DIRECTLY TO THE INTERIOR OF EXTERIOR MASONRY
WALLS OR CONCRETE WALLS BELOW GRADE EXCEPT WHERE AN APPROVED VAPOR RETARDER IS APPLIED BETWEEN THE WALL
AND THE FURRING STRIPS OR FRAMING MEMBERS.
*HERS VERIFICATION REQUIRED-REFERENCE T-24.1
ROOM TAGROOM NAME
1
1
1
1
10.00'SPOT ELEVATION
REVISION TAG
DOOR TAG
WINDOW WALL TAG
WINDOW TAG
STRUCTURAL STEEL COLUMN PER STRUCT., REF. STRUTC.
DWGS, -PAINT AND SEAL AS REQUIRED –ARCH. TO APPV.
COLOR FOR EXPOSED STEEL COLUMNS
STRUCTURAL WOOD POST/COLUMN COLUMN -PER STRUCT., REF. STRUTC. DWGS, -
PAINT, STAIN AND SEAL AS REQUIRED –ARCH. TO APPV. PAINT COLOR FOR EXPOSED
WOOD POST/COLUMN, IF TO BE STAINED PROVIDE STAINED SAMPLE FOR ARCH,
APPROVAL
KITCHEN RANGE W/. EXHAUST HOOD -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –
PROVIDE POWER AND GAS AS REQUIRED -30”MIN. VERTICAL CLEARANCE TO ANY
COMBUSTIBLE MATERIAL ABV. COOKING TOP (CMC 920.3.2) –EXHAUST HOOD TO HAVE
EXHAUST RATE OF MIN. 100 CFM AND VENT TO OUTDOOR , HOOD DUCTS TO BE OF
METAL WITH SMOOTH INTERIOR FINISH PER SECTION 504.3 OF CMC
KITCHEN/BAR SINK -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –SINK TO COMPLY
W/. REQUIREMENT OF SECTION 420.0 OF CPC AND HAVE A MAX FLOW RATE OF 1.8 GPM
@ 60 PSI PER SECTION 4.303.1 OF CALGREEN –TRAP AND VENT FOR ISLAND SINK AND
SIMILAR EQUIPMENT SHALL BE PER SECTION 909.0 OF CPC
VANITY SINK -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –
LAVATORY TO HAVE 24”MIN. CLEAR SPACE IN FRONT OF IT.(CPC 402.5)
W/. MAXIMUM FLOW RATE OF 1.2 GPM @ 60 PSI AND MIN. FLOW RATE OF
0.8 GPM @ 20 PSI PER SECTION 4.303.1 OF CALGREEN
WASHER (W) / DRYER (D) / STACKED (W/D)-AS SELECTED PER I.D., VERIFY W/. I.D. &
OWNER –PROVIDE POWER , GAS, WATER SUPPLY & DRAINAGE AS REQUIRED -THE
CLOTHES DRYERS VENT SHALL BE OF A RIGID METALLIC MATERIAL AND HAVE A
BACKDRAFT DAMPER (CMC 504.4) AND SHALL NOT EXCEED 14-FEET IN OVERALL LENGTH
WITH MAX. OF TWO (2) 90-DEGREE ELBOW, SUBTRACT 2-FEET FOR EACH ADDITIONAL 90-
DEGREE ELBOW. SEE WASHER & DRYER NOTES, REF. T-1.1.
TOILET -WATER CLOSET SHALL BE IN COMPLIANCE OF SECTION 411.0 OF CPC AND HAS
MAX EFFECTIVE FLUSH RATE OF 1.28 GAL. PER FLUSH (CPC 411.2). WATER CLOSETS
CLR. TO BE 24”IN FRONT AND 15”FROM ITS CENTER TO ANY SIDE WALL OR
OBSTRUCTION. (CPC 402.5 & CRC R307) –REF. CALGREEN NOTES ON T SHTS. FOR MAX
FLOW RATE
FIREPLACE -FACTORY-BUILT DIRECT VENT GAS FIREPLACE W/. SEALED COMBUSTION
(CALGREEN 4.503) -FACTORY-BUILT FIREPLACES, CHIMNEYS AND ALL OF THEIR
COMPONENTS SHALL BE LISTED AND INSTALLED IN ACCORDANCE WITH THEIR LISTING
AND MANUFACTURER'S INSTALLATION INSTRUCTIONS. (CRC R1004.1)
A/C CONDENSER / HEAT PUMP -TO BE IN COMPLIANCE OF SECTION 307.3 OF CPC AS
SELECTED, VERIFY W/. OWNER -SIZE TBD, SEE T-24 ENERGY REPORT FOR MORE INFO –
PROVIDE POWER AND SOUND DAMPENING PAD AS REQ’D. –INSTALL AND MAINTAIN
REQUIRED CLEARANCES PER MFGR. INSTRUCTION
FAU -PROVIDE GAS S.O., POWER, AND VENTING AS REQ'D. BY MFG'R. –INSTALL PER
MFGR. INSTRUCTION
RECESSED MAIN SERVICE PANEL -400 AMP MAX. (MAINTAIN 36" CLEAR FROM FACE
OF PANEL TO ANY OBSTRUCTION) –GC TO COORDINATE W/. UTILITY COMPANY
ROOF/DECK DRAIN -PER CHAPTER 11 OF CPC -SIZE THE DRAIN AND PIPING PER TABLE
1103.1 AND 1103.2 OF CPC –ROOF DRAIN SHALL HAVE DOMED STRAINER (CPC 1102.2) –
REF. DETAIL 11/AD-1.0
OVERFLOW OR EMERGENCY DRAIN -PER CHAPTER 11 OF CPC -COPPER OR EQ., INSTALL
PER MFGR. INSTRUC., SLOPED TOWARD IN-WALL DRAIN INLETS –SLOPE AND SIZE PER
TABLE 1103.3 OF CPC –REF. DTL. 11/AD-1.0
2X4 STUD WALL
2X6 STUD WALL
2X8 STUD WALL
2X10 STUD WALL
EXT. POCKET DOOR WALL - TYP. 2X6 EXT. FRMG. AND 2X4 INTERIOR FRAMING W/.
DOUBLE TOP PLATE AND SINGLE SILL PLATE U.N.O., MIN. AIR SPACE/DOOR POCKET
TO BE VERIFIED W/. DOOR MFGR. - STUDS MIN. SPACING PER STRUCT. AND EXT.
FINISH MFGR. INSTRUCTION AND/OR LISTING –SEE EXT. WALL DETAILS AND STRUCT.
DWGS
CONCRETE WALL -12”REINFORCED CAST IN PLACE CONCRETE WALL TYP. U.N.O. PER
STRUCT., REF. STRCUTC. DWGS. –FOR BASEMENT/RETAINING CONCRETE WALL
PROVIDE WATERPROOFING OR DAMPPROOFING AND DRAINAGE AS REQUIRED PER
SECTION R406.1 & R406.2, REF. SOILS REPORT,WATERPROOFING & DAMPROOFING
NOTES ON SHEET T-1.1 –EXPOSED SURFACES TO HAVE TROWELED SMOOTH FINISH
WITH A LIGHT GRAY COLOR, PROVIDE SAMPLE FOR ARCH. APPROVAL
SLAB/FRAMING DEPRESSION -SEE STRUCT. DWGS. FOR THE RECESSION DETAILS -
FOR RECESSION SPECIFIC TO EQUIPMENT OR ASSEMBLY VERIFY THE REQUIRED
RECESSION W/. MFGR. OR FABRICATOR –SHOWER RECESSION TO BE VERIFIED W/.
I.D.
SEE SHEET AD-2.0 FOR THE TYPICAL DEPRESSION OF DOORS AND WINDOWS, VERIFY
ALL DEPRESSIONS W/. MFGR.
STUDS MIN. SPACING PER STRUCT. AND EXT. FINISH MFGR.
INSTRUCTION AND/OR LISTING –SEE EXT. WALL DETAILS AND
STRUCT. DWGS
VERTICAL STORM DRAIN PIPE IN-WALL / OVERFLOW -MTL. PIPE PER
CHAPTER 11 OF CPC, SIZE PER TABLE 1103.1 (MIN. 2”DIA. PIPE & TYP. 3”DIA. PIPE) –
SEE CIVIL DWGS. FOR TERMINATION DTLS. ABV. OR BLW. GROUND. VERIFY ALL
TERMINATION POINTS, TYPE AND DETAILS W/. CIVIL PRIOR TO POURING THE CONCRETE
SLAB
OVERFLOW
DRAINLINE
A-4.1
A-4.0
A-4.03A-4.1
1
1
2
1
A-5.0
1
A-5.0
3
A-5.0
3
A-5.0
2
A-5.0
2
A-5.0
PANTRY
KITCHEN
DINING
GREAT ROOM
ENTRY
SLOPE PER CIVIL
SLAB DEPRESSION FOR
POCKET DOORS. VERIFY
W/. G.C. AND MFGR.
SLAB DEPRESSION
FOR SHOWER
VERIFY W/. G.C.
18' - 2"4' - 2"71' - 8"
22' - 6 1/4"16' - 5 1/8"18' - 3 3/8"14' - 5 1/4"
4' - 2"71' - 8"13' - 2"
22' - 6 1/4"15' - 10 5/8"9' - 5"9' - 4 7/8"14' - 5 1/4"
8' - 0 1/8"6' - 6 1/8"8' - 0 1/8"3' - 7 1/8"3' - 9"3' - 9"4' - 9 3/8"4' - 8 1/2"4' - 8 1/2"4' - 11 1/8"4' - 5 3/4"3' - 3"6' - 5"4' - 9 1/4"
17
'
-
2
1
/
2
"
33
'
-
9
7
/
8
"
5'
-
2
"
1'
-
4
3
/
4
"
4'
-
1
1
"
24
'
-
0
"
4'
-
1
1
"
8'
-
2
"
26
'
-
0
"
6'
-
1
1
"
4'
-
0
"
8'
-
2
"
6'
-
1
1
"
PWD. 1
FOYER
STAIRS
STOR.
CART GARAGE / GYM
BEDROOM 1
BATH 1
SLAB DEPRESSION FOR
FIREPLACE. VERIFY W/.
G.C. AND MFGR.
10.00' F.F.
11.00' F.F.11.00' F.F.
5' - 9 1/8"11' - 0"5' - 9 1/8"4' - 3 5/8"5' - 6 1/8"2' - 6 5/8"4' - 0 5/8"8' - 9 5/8"4' - 7 7/8"4' - 9 7/8"2' - 11 1/2"8' - 7 1/4"2' - 10 1/2"
4
1 2
3 4
5
6 7
8
23
10
9
10
11
8
11
9
13 1214
5
6
7
1'
-
5
"
11
1
/
2
"
3'
-
6
"
5"
1'
-
1
"
C.C.
1
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
BRANDON ARCHITECTS
ANNOTATION LEGEND
GENERAL NOTESA
B
01/20/2023
FIRST LEVEL
DIMENSION PLAN
MI
L
L
E
R
R
E
S
I
D
E
N
C
E
MR. & MRS. MATTHEW MILLER
22 BAY ISLAND,
NEWPORT BEACH, CA 92661
P: 949.235.9286
millermg123@gmail.com
CDP
22 BAY ISLAND
NEWPORT BEACH, CA 92661
A-2.3
TBD
BRIAN JOWETT
NO. REVISION DATE
1/4" = 1'-0"1 FIRST LEVEL DIMENSION PLAN
UP
DN
DIMENSION NOTE:
ALL DIMENSIONS ARE TO FACE OF SHEATHING (EXT. WALLS) OR FACE OF STRUCTURE (F.O.S.) TYP. U.N.O. ROUNDED TO THE
NEAREST 1/8" AND INTERIOR PARTITIONS ARE DIMENSIONED FROM FACE OF STRUCTURE TO FACE OF STRUCTURE (F.O.S.) U.N.O. -
CONTACT ARCHITECT IN WRITING FOR ANY CLARIFICATION OF NOTED DIMENSIONS, DO NOT SCALE PLANS.
ROUGH FRAMING:
ALL EXTERIOR WALLS TO BE FRAMED W/. 2X6 STUD MIN. U.N.O.
USE 2X6 MINIMUM STUDS FOR PLUMBING WALLS
SECOND AND THIRD FLOOR PLYWOOD TO BE 1-1/8"
ENTIRE EXTERIOR TO BE SHEATHED WITH 1/2" PLYWOOD
DOORS AND WINDOWS WILL TYPICALLY BE RECESSED FROM EXTERIOR WALL PLANE. VERIFY ALL ROUGH OPENING DIMENSIONS
WITH DOOR AND WINDOW MFGR. ROUGH OPENING MAY NEED TO BE OVERSIZED TO ACCOUNT FOR ADDITIONAL FRAMING. SEE
SHT. AD-2.0 FOR TYP. RECESSED CONDITIONS.
GARAGE FLOOR:
GARAGE FLOOR SURFACES SHALL BE OF APPROVED NONCOMBUSTIBLE MATERIAL.THE AREA OF FLOOR USED FOR PARKING OF
AUTOMOBILES OR OTHER VEHICLES SHALL BE SLOPED TO FACILITATE THE MOVEMENT OF LIQUIDS TO A DRAIN OR TOWARD THE
MAIN VEHICLE ENTRY DOORWAY. (R309.1)
PLUMBING:
1. SUPPORT ALL WALL-HUNG FIXTURES WITH METAL SUPPORTING MEMBERS TO PREVENT ANY STRAIN TRANSMISSION TO THE
CONNECTIONS. FRAMING AFFIXED SUPPORTS FOR OFF-THE-FLOOR WATER CLOSETS WITH CONCEALED TANKS SHALL COMPLY
WITH ASME A112.6.2. SECURE FLUSH TANK AND SIMILAR APPURTENANCES WITH APPROVED NON-CORROSIVE SCREW OR BOLTS.
(CPC 402.5)
2. THE NET AREA OF THE SHOWER ENCLOSURE SHALL BE 1,024 SQ. INCHES (7.1 SQ. FT.) OR MORE IN THE CLEAR FLOOR AREA,
AND SHALL ALSO BE CAPABLE OF ENCOMPASSING A 30-INCH DIAMETER CIRCLE. (CPC 408.6)
3. THE WATER HEATER BURNER AND BURNER-IGNITION DEVICE TO BE AT LEAST 18-INCHES ABOVE THE FLOOR, IF LOCATED IN A
GARAGE AND IN ADJACENT SPACES THAT OPEN TO THE GARAGE. FOR WATER HEATER IN THE GARAGE OR OTHER AREAS SUBJECT
TO MECHANICAL DAMAGE PROVIDE A PROTECTIVE BARRIER OR ELEVATE THE APPLIANCE TO BE OUT OF THE NORMAL PATH OF
THE VEHICLE. (CPC 507.13)
4. ANCHOR OR STRAP THE WATER HEATER(S) TO RESIST HORIZ. DISPLACEMENT DUE TO THE EARTHQUAKE. STRAPPING SHOULD
BE AT THE UPPER AND LOWER ONE THIRD (1/3) POINTS OF THE APPLIANCE HEIGHT. MAINTAIN A MIN. 4-INCHES ABOVE THE
CONTROLS WITH STRAPPING AT LOWER POINT.
WOOD OR WOODBASED PRODUCTS NOTE:
WOOD OR WOODBASE PRODUCT SHALL BE OF A NATURAL DURABLE OR PRESERVATIVE-TREADED WOOD IN ACCORDANCE WITH
AWPA U1 FOR THE SPECIES, PRODUCT, PRESERVATIVE AND END USE IN THE FOLLOWING LOCATIONS:
1. WOOD JOISTS OR THE BOTTOM OF A WOOD STRUCTURAL FLOOR WHEN CLOSER THAN 18 INCHES (457 MM) OR WOOD GIRDERS
WHEN CLOSER THAN 12 INCHES (305 MM) TO THE EXPOSED GROUND IN CRAWL SPACES OR UNEXCAVATED AREA LOCATED
WITHIN THE PERIPHERY OF THE BUILDING FOUNDATION.
2. WOOD FRAMING MEMBERS THAT REST ON CONCRETE OR MASONRY EXTERIOR FOUNDATION WALLS AND ARE LESS THAN 8
INCHES (203 MM) FROM THE EXPOSED GROUND.
3. SILLS AND SLEEPERS ON A CONCRETE OR MASONRY SLAB THAT IS IN DIRECT CONTACT WITH THE GROUND UNLESS
SEPARATED FROM SUCH SLAB BY AN IMPERVIOUS MOISTURE BARRIER.
4. THE ENDS OF WOOD GIRDERS ENTERING EXTERIOR MASONRY OR CONCRETE WALLS HAVING CLEARANCES OF LESS THAN 1/2
INCH (12.7 MM) ON TOPS, SIDES AND ENDS.
5. WOOD SIDING, SHEATHING AND WALL FRAMING ON THE EXTERIOR OF A BUILDING HAVING A CLEARANCE OF LESS THAN 6
INCHES (152 MM) FROM THE GROUND OR LESS THAN 2 INCHES (51 MM) MEASURED VERTICALLY FROM CONCRETE STEPS,
PORCH SLABS, PATIO SLABS AND SIMILAR HORIZONTAL SURFACES EXPOSED TO THE WEATHER.
6. WOOD STRUCTURAL MEMBERS SUPPORTING MOISTURE-PERMEABLE FLOORS OR ROOFS THAT ARE EXPOSED TO THE
WEATHER, SUCH AS CONCRETE OR MASONRY SLABS, UNLESS SEPARATED FROM SUCH FLOORS OR ROOFS BY AN IMPERVIOUS
MOISTURE BARRIER.
7. WOOD FURRING STRIPS OR OTHER WOOD FRAMING MEMBERS ATTACHED DIRECTLY TO THE INTERIOR OF EXTERIOR MASONRY
WALLS OR CONCRETE WALLS BELOW GRADE EXCEPT WHERE AN APPROVED VAPOR RETARDER IS APPLIED BETWEEN THE WALL
AND THE FURRING STRIPS OR FRAMING MEMBERS.
*HERS VERIFICATION REQUIRED-REFERENCE T-24.1
ROOM TAGROOM NAME
1
1
1
1
10.00'SPOT ELEVATION
REVISION TAG
DOOR TAG
WINDOW WALL TAG
WINDOW TAG
STRUCTURAL STEEL COLUMN PER STRUCT., REF. STRUTC.
DWGS, -PAINT AND SEAL AS REQUIRED –ARCH. TO APPV.
COLOR FOR EXPOSED STEEL COLUMNS
STRUCTURAL WOOD POST/COLUMN COLUMN -PER STRUCT., REF. STRUTC. DWGS, -
PAINT, STAIN AND SEAL AS REQUIRED –ARCH. TO APPV. PAINT COLOR FOR EXPOSED
WOOD POST/COLUMN, IF TO BE STAINED PROVIDE STAINED SAMPLE FOR ARCH,
APPROVAL
KITCHEN RANGE W/. EXHAUST HOOD -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –
PROVIDE POWER AND GAS AS REQUIRED -30”MIN. VERTICAL CLEARANCE TO ANY
COMBUSTIBLE MATERIAL ABV. COOKING TOP (CMC 920.3.2) –EXHAUST HOOD TO HAVE
EXHAUST RATE OF MIN. 100 CFM AND VENT TO OUTDOOR , HOOD DUCTS TO BE OF
METAL WITH SMOOTH INTERIOR FINISH PER SECTION 504.3 OF CMC
KITCHEN/BAR SINK -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –SINK TO COMPLY
W/. REQUIREMENT OF SECTION 420.0 OF CPC AND HAVE A MAX FLOW RATE OF 1.8 GPM
@ 60 PSI PER SECTION 4.303.1 OF CALGREEN –TRAP AND VENT FOR ISLAND SINK AND
SIMILAR EQUIPMENT SHALL BE PER SECTION 909.0 OF CPC
VANITY SINK -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –
LAVATORY TO HAVE 24”MIN. CLEAR SPACE IN FRONT OF IT.(CPC 402.5)
W/. MAXIMUM FLOW RATE OF 1.2 GPM @ 60 PSI AND MIN. FLOW RATE OF
0.8 GPM @ 20 PSI PER SECTION 4.303.1 OF CALGREEN
WASHER (W) / DRYER (D) / STACKED (W/D)-AS SELECTED PER I.D., VERIFY W/. I.D. &
OWNER –PROVIDE POWER , GAS, WATER SUPPLY & DRAINAGE AS REQUIRED -THE
CLOTHES DRYERS VENT SHALL BE OF A RIGID METALLIC MATERIAL AND HAVE A
BACKDRAFT DAMPER (CMC 504.4) AND SHALL NOT EXCEED 14-FEET IN OVERALL LENGTH
WITH MAX. OF TWO (2) 90-DEGREE ELBOW, SUBTRACT 2-FEET FOR EACH ADDITIONAL 90-
DEGREE ELBOW. SEE WASHER & DRYER NOTES, REF. T-1.1.
TOILET -WATER CLOSET SHALL BE IN COMPLIANCE OF SECTION 411.0 OF CPC AND HAS
MAX EFFECTIVE FLUSH RATE OF 1.28 GAL. PER FLUSH (CPC 411.2). WATER CLOSETS
CLR. TO BE 24”IN FRONT AND 15”FROM ITS CENTER TO ANY SIDE WALL OR
OBSTRUCTION. (CPC 402.5 & CRC R307) –REF. CALGREEN NOTES ON T SHTS. FOR MAX
FLOW RATE
FIREPLACE -FACTORY-BUILT DIRECT VENT GAS FIREPLACE W/. SEALED COMBUSTION
(CALGREEN 4.503) -FACTORY-BUILT FIREPLACES, CHIMNEYS AND ALL OF THEIR
COMPONENTS SHALL BE LISTED AND INSTALLED IN ACCORDANCE WITH THEIR LISTING
AND MANUFACTURER'S INSTALLATION INSTRUCTIONS. (CRC R1004.1)
A/C CONDENSER / HEAT PUMP -TO BE IN COMPLIANCE OF SECTION 307.3 OF CPC AS
SELECTED, VERIFY W/. OWNER -SIZE TBD, SEE T-24 ENERGY REPORT FOR MORE INFO –
PROVIDE POWER AND SOUND DAMPENING PAD AS REQ’D. –INSTALL AND MAINTAIN
REQUIRED CLEARANCES PER MFGR. INSTRUCTION
FAU -PROVIDE GAS S.O., POWER, AND VENTING AS REQ'D. BY MFG'R. –INSTALL PER
MFGR. INSTRUCTION
RECESSED MAIN SERVICE PANEL -400 AMP MAX. (MAINTAIN 36" CLEAR FROM FACE
OF PANEL TO ANY OBSTRUCTION) –GC TO COORDINATE W/. UTILITY COMPANY
ROOF/DECK DRAIN -PER CHAPTER 11 OF CPC -SIZE THE DRAIN AND PIPING PER TABLE
1103.1 AND 1103.2 OF CPC –ROOF DRAIN SHALL HAVE DOMED STRAINER (CPC 1102.2) –
REF. DETAIL 11/AD-1.0
OVERFLOW OR EMERGENCY DRAIN -PER CHAPTER 11 OF CPC -COPPER OR EQ., INSTALL
PER MFGR. INSTRUC., SLOPED TOWARD IN-WALL DRAIN INLETS –SLOPE AND SIZE PER
TABLE 1103.3 OF CPC –REF. DTL. 11/AD-1.0
2X4 STUD WALL
2X6 STUD WALL
2X8 STUD WALL
2X10 STUD WALL
EXT. POCKET DOOR WALL - TYP. 2X6 EXT. FRMG. AND 2X4 INTERIOR FRAMING W/.
DOUBLE TOP PLATE AND SINGLE SILL PLATE U.N.O., MIN. AIR SPACE/DOOR POCKET
TO BE VERIFIED W/. DOOR MFGR. - STUDS MIN. SPACING PER STRUCT. AND EXT.
FINISH MFGR. INSTRUCTION AND/OR LISTING –SEE EXT. WALL DETAILS AND STRUCT.
DWGS
CONCRETE WALL -12”REINFORCED CAST IN PLACE CONCRETE WALL TYP. U.N.O. PER
STRUCT., REF. STRCUTC. DWGS. –FOR BASEMENT/RETAINING CONCRETE WALL
PROVIDE WATERPROOFING OR DAMPPROOFING AND DRAINAGE AS REQUIRED PER
SECTION R406.1 & R406.2, REF. SOILS REPORT,WATERPROOFING & DAMPROOFING
NOTES ON SHEET T-1.1 –EXPOSED SURFACES TO HAVE TROWELED SMOOTH FINISH
WITH A LIGHT GRAY COLOR, PROVIDE SAMPLE FOR ARCH. APPROVAL
SLAB/FRAMING DEPRESSION -SEE STRUCT. DWGS. FOR THE RECESSION DETAILS -
FOR RECESSION SPECIFIC TO EQUIPMENT OR ASSEMBLY VERIFY THE REQUIRED
RECESSION W/. MFGR. OR FABRICATOR –SHOWER RECESSION TO BE VERIFIED W/.
I.D.
SEE SHEET AD-2.0 FOR THE TYPICAL DEPRESSION OF DOORS AND WINDOWS, VERIFY
ALL DEPRESSIONS W/. MFGR.
STUDS MIN. SPACING PER STRUCT. AND EXT. FINISH MFGR.
INSTRUCTION AND/OR LISTING –SEE EXT. WALL DETAILS AND
STRUCT. DWGS
VERTICAL STORM DRAIN PIPE IN-WALL / OVERFLOW -MTL. PIPE PER
CHAPTER 11 OF CPC, SIZE PER TABLE 1103.1 (MIN. 2”DIA. PIPE & TYP. 3”DIA. PIPE) –
SEE CIVIL DWGS. FOR TERMINATION DTLS. ABV. OR BLW. GROUND. VERIFY ALL
TERMINATION POINTS, TYPE AND DETAILS W/. CIVIL PRIOR TO POURING THE CONCRETE
SLAB
OVERFLOW
DRAINLINE
A-4.1
A-4.0
A-4.03A-4.1
1
1
2
1
A-5.0
1
A-5.0
3
A-5.0
3
A-5.0
2
A-5.0
2
A-5.0
BEDROOM 2
BEDROOM 3
W.I.C.
BATH 4
STUDY
PRIMARY BEDROOM
PRIMARY CLOSET
W/C
BUNK ROOMBATH 3
BATH 2
PRIMARY BATH
BALCONY 2
BALCONY 3
PRIMARY BALCONY
SLAB DEPRESSION
FOR SHOWER
VERIFY W/. G.C.
SLAB DEPRESSION
FOR SHOWER
VERIFY W/. G.C.
SLAB DEPRESSION FOR
SHOWER VERIFY W/. G.C.
SLAB DEPRESSION
FOR SHOWER
VERIFY W/. G.C.
4' - 2"71' - 8"18' - 2"
5' - 2"22' - 6 1/4"16' - 5 1/8"18' - 3 3/8"14' - 5 1/4"4' - 2"
4' - 9 1/8"6' - 6"6' - 6"4' - 9 1/8"4' - 3 5/8"12' - 1 3/8"8' - 3 7/8"5' - 1 3/4"4' - 9 3/4"2' - 11 1/2"8' - 7 1/4"2' - 10 1/2"
17
'
-
2
1
/
2
"
33
'
-
9
7
/
8
"
5'
-
2
"
4' - 2"71' - 8"13' - 2"5' - 0"
5' - 3 1/8"2' - 9"6' - 6 1/8"1' - 9"6' - 3 1/8"6' - 7 3/8"3' - 3"3' - 3"2' - 9 1/8"3' - 2 1/2"3' - 0"3' - 2 1/2"4' - 7 1/8"4' - 9 3/4"7' - 3 1/8"7' - 2 1/8"
22' - 6 1/4"15' - 10 5/8"9' - 5"9' - 4 7/8"
14' - 5 1/4"
1'
-
1
1
"
5'
-
0
"
5'
-
0
"
2'
-
2
"
5'
-
0
"
5'
-
0
"
1'
-
1
1
"
26
'
-
0
"
8'
-
2
"
22.26' F.F.
22.26' F.F.
SLOPE
2% MIN.
SLOPE
2% MIN.
SLOPE
2% MIN.
18
16
3031
19
18
20
21 22
24
23
14
25
26
27 15
2324
1'
-
4
3
/
4
"
4'
-
1
1
/
2
"
9 1
/
2
"
24
'
-
0
"
9
1
/
2
"
4'
-
1
1
/
2
"
SLAB DEPRESSION FOR
FIREPLACE. VERIFY W/.
G.C. AND MFGR.
5"
3'
-
6
"
1'
-
1
"
15 16 17
19
1
2
22
2
20
21
12
13
2526
28 2729
17
11
1
/
2
"
1'
-
5
"
SLAB DEPRESSION FOR
POCKET DOORS. VERIFY
W/. G.C. AND MFGR.
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
BRANDON ARCHITECTS
ANNOTATION LEGEND
GENERAL NOTESA
B
01/20/2023
SECOND LEVEL
DIMENSION PLAN
MI
L
L
E
R
R
E
S
I
D
E
N
C
E
MR. & MRS. MATTHEW MILLER
22 BAY ISLAND,
NEWPORT BEACH, CA 92661
P: 949.235.9286
millermg123@gmail.com
CDP
22 BAY ISLAND
NEWPORT BEACH, CA 92661
A-2.4
TBD
BRIAN JOWETT
NO. REVISION DATE
1/4" = 1'-0"1 SECOND LEVEL DIMENSION PLAN
DN
DIMENSION NOTE:
ALL DIMENSIONS ARE TO FACE OF SHEATHING (EXT. WALLS) OR FACE OF STRUCTURE (F.O.S.) TYP. U.N.O. ROUNDED TO THE
NEAREST 1/8" AND INTERIOR PARTITIONS ARE DIMENSIONED FROM FACE OF STRUCTURE TO FACE OF STRUCTURE (F.O.S.) U.N.O. -
CONTACT ARCHITECT IN WRITING FOR ANY CLARIFICATION OF NOTED DIMENSIONS, DO NOT SCALE PLANS.
ROUGH FRAMING:
ALL EXTERIOR WALLS TO BE FRAMED W/. 2X6 STUD MIN. U.N.O.
USE 2X6 MINIMUM STUDS FOR PLUMBING WALLS
SECOND AND THIRD FLOOR PLYWOOD TO BE 1-1/8"
ENTIRE EXTERIOR TO BE SHEATHED WITH 1/2" PLYWOOD
DOORS AND WINDOWS WILL TYPICALLY BE RECESSED FROM EXTERIOR WALL PLANE. VERIFY ALL ROUGH OPENING DIMENSIONS
WITH DOOR AND WINDOW MFGR. ROUGH OPENING MAY NEED TO BE OVERSIZED TO ACCOUNT FOR ADDITIONAL FRAMING. SEE
SHT. AD-2.0 FOR TYP. RECESSED CONDITIONS.
GARAGE FLOOR:
GARAGE FLOOR SURFACES SHALL BE OF APPROVED NONCOMBUSTIBLE MATERIAL.THE AREA OF FLOOR USED FOR PARKING OF
AUTOMOBILES OR OTHER VEHICLES SHALL BE SLOPED TO FACILITATE THE MOVEMENT OF LIQUIDS TO A DRAIN OR TOWARD THE
MAIN VEHICLE ENTRY DOORWAY. (R309.1)
PLUMBING:
1. SUPPORT ALL WALL-HUNG FIXTURES WITH METAL SUPPORTING MEMBERS TO PREVENT ANY STRAIN TRANSMISSION TO THE
CONNECTIONS. FRAMING AFFIXED SUPPORTS FOR OFF-THE-FLOOR WATER CLOSETS WITH CONCEALED TANKS SHALL COMPLY
WITH ASME A112.6.2. SECURE FLUSH TANK AND SIMILAR APPURTENANCES WITH APPROVED NON-CORROSIVE SCREW OR BOLTS.
(CPC 402.5)
2. THE NET AREA OF THE SHOWER ENCLOSURE SHALL BE 1,024 SQ. INCHES (7.1 SQ. FT.) OR MORE IN THE CLEAR FLOOR AREA,
AND SHALL ALSO BE CAPABLE OF ENCOMPASSING A 30-INCH DIAMETER CIRCLE. (CPC 408.6)
3. THE WATER HEATER BURNER AND BURNER-IGNITION DEVICE TO BE AT LEAST 18-INCHES ABOVE THE FLOOR, IF LOCATED IN A
GARAGE AND IN ADJACENT SPACES THAT OPEN TO THE GARAGE. FOR WATER HEATER IN THE GARAGE OR OTHER AREAS SUBJECT
TO MECHANICAL DAMAGE PROVIDE A PROTECTIVE BARRIER OR ELEVATE THE APPLIANCE TO BE OUT OF THE NORMAL PATH OF
THE VEHICLE. (CPC 507.13)
4. ANCHOR OR STRAP THE WATER HEATER(S) TO RESIST HORIZ. DISPLACEMENT DUE TO THE EARTHQUAKE. STRAPPING SHOULD
BE AT THE UPPER AND LOWER ONE THIRD (1/3) POINTS OF THE APPLIANCE HEIGHT. MAINTAIN A MIN. 4-INCHES ABOVE THE
CONTROLS WITH STRAPPING AT LOWER POINT.
WOOD OR WOODBASED PRODUCTS NOTE:
WOOD OR WOODBASE PRODUCT SHALL BE OF A NATURAL DURABLE OR PRESERVATIVE-TREADED WOOD IN ACCORDANCE WITH
AWPA U1 FOR THE SPECIES, PRODUCT, PRESERVATIVE AND END USE IN THE FOLLOWING LOCATIONS:
1. WOOD JOISTS OR THE BOTTOM OF A WOOD STRUCTURAL FLOOR WHEN CLOSER THAN 18 INCHES (457 MM) OR WOOD GIRDERS
WHEN CLOSER THAN 12 INCHES (305 MM) TO THE EXPOSED GROUND IN CRAWL SPACES OR UNEXCAVATED AREA LOCATED
WITHIN THE PERIPHERY OF THE BUILDING FOUNDATION.
2. WOOD FRAMING MEMBERS THAT REST ON CONCRETE OR MASONRY EXTERIOR FOUNDATION WALLS AND ARE LESS THAN 8
INCHES (203 MM) FROM THE EXPOSED GROUND.
3. SILLS AND SLEEPERS ON A CONCRETE OR MASONRY SLAB THAT IS IN DIRECT CONTACT WITH THE GROUND UNLESS
SEPARATED FROM SUCH SLAB BY AN IMPERVIOUS MOISTURE BARRIER.
4. THE ENDS OF WOOD GIRDERS ENTERING EXTERIOR MASONRY OR CONCRETE WALLS HAVING CLEARANCES OF LESS THAN 1/2
INCH (12.7 MM) ON TOPS, SIDES AND ENDS.
5. WOOD SIDING, SHEATHING AND WALL FRAMING ON THE EXTERIOR OF A BUILDING HAVING A CLEARANCE OF LESS THAN 6
INCHES (152 MM) FROM THE GROUND OR LESS THAN 2 INCHES (51 MM) MEASURED VERTICALLY FROM CONCRETE STEPS,
PORCH SLABS, PATIO SLABS AND SIMILAR HORIZONTAL SURFACES EXPOSED TO THE WEATHER.
6. WOOD STRUCTURAL MEMBERS SUPPORTING MOISTURE-PERMEABLE FLOORS OR ROOFS THAT ARE EXPOSED TO THE
WEATHER, SUCH AS CONCRETE OR MASONRY SLABS, UNLESS SEPARATED FROM SUCH FLOORS OR ROOFS BY AN IMPERVIOUS
MOISTURE BARRIER.
7. WOOD FURRING STRIPS OR OTHER WOOD FRAMING MEMBERS ATTACHED DIRECTLY TO THE INTERIOR OF EXTERIOR MASONRY
WALLS OR CONCRETE WALLS BELOW GRADE EXCEPT WHERE AN APPROVED VAPOR RETARDER IS APPLIED BETWEEN THE WALL
AND THE FURRING STRIPS OR FRAMING MEMBERS.
*HERS VERIFICATION REQUIRED-REFERENCE T-24.1
ROOM TAGROOM NAME
1
1
1
1
10.00'SPOT ELEVATION
REVISION TAG
DOOR TAG
WINDOW WALL TAG
WINDOW TAG
STRUCTURAL STEEL COLUMN PER STRUCT., REF. STRUTC.
DWGS, -PAINT AND SEAL AS REQUIRED –ARCH. TO APPV.
COLOR FOR EXPOSED STEEL COLUMNS
STRUCTURAL WOOD POST/COLUMN COLUMN -PER STRUCT., REF. STRUTC. DWGS, -
PAINT, STAIN AND SEAL AS REQUIRED –ARCH. TO APPV. PAINT COLOR FOR EXPOSED
WOOD POST/COLUMN, IF TO BE STAINED PROVIDE STAINED SAMPLE FOR ARCH,
APPROVAL
KITCHEN RANGE W/. EXHAUST HOOD -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –
PROVIDE POWER AND GAS AS REQUIRED -30”MIN. VERTICAL CLEARANCE TO ANY
COMBUSTIBLE MATERIAL ABV. COOKING TOP (CMC 920.3.2) –EXHAUST HOOD TO HAVE
EXHAUST RATE OF MIN. 100 CFM AND VENT TO OUTDOOR , HOOD DUCTS TO BE OF
METAL WITH SMOOTH INTERIOR FINISH PER SECTION 504.3 OF CMC
KITCHEN/BAR SINK -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –SINK TO COMPLY
W/. REQUIREMENT OF SECTION 420.0 OF CPC AND HAVE A MAX FLOW RATE OF 1.8 GPM
@ 60 PSI PER SECTION 4.303.1 OF CALGREEN –TRAP AND VENT FOR ISLAND SINK AND
SIMILAR EQUIPMENT SHALL BE PER SECTION 909.0 OF CPC
VANITY SINK -AS SELECTED PER I.D., VERIFY W/. I.D. & OWNER –
LAVATORY TO HAVE 24”MIN. CLEAR SPACE IN FRONT OF IT.(CPC 402.5)
W/. MAXIMUM FLOW RATE OF 1.2 GPM @ 60 PSI AND MIN. FLOW RATE OF
0.8 GPM @ 20 PSI PER SECTION 4.303.1 OF CALGREEN
WASHER (W) / DRYER (D) / STACKED (W/D)-AS SELECTED PER I.D., VERIFY W/. I.D. &
OWNER –PROVIDE POWER , GAS, WATER SUPPLY & DRAINAGE AS REQUIRED -THE
CLOTHES DRYERS VENT SHALL BE OF A RIGID METALLIC MATERIAL AND HAVE A
BACKDRAFT DAMPER (CMC 504.4) AND SHALL NOT EXCEED 14-FEET IN OVERALL LENGTH
WITH MAX. OF TWO (2) 90-DEGREE ELBOW, SUBTRACT 2-FEET FOR EACH ADDITIONAL 90-
DEGREE ELBOW. SEE WASHER & DRYER NOTES, REF. T-1.1.
TOILET -WATER CLOSET SHALL BE IN COMPLIANCE OF SECTION 411.0 OF CPC AND HAS
MAX EFFECTIVE FLUSH RATE OF 1.28 GAL. PER FLUSH (CPC 411.2). WATER CLOSETS
CLR. TO BE 24”IN FRONT AND 15”FROM ITS CENTER TO ANY SIDE WALL OR
OBSTRUCTION. (CPC 402.5 & CRC R307) –REF. CALGREEN NOTES ON T SHTS. FOR MAX
FLOW RATE
FIREPLACE -FACTORY-BUILT DIRECT VENT GAS FIREPLACE W/. SEALED COMBUSTION
(CALGREEN 4.503) -FACTORY-BUILT FIREPLACES, CHIMNEYS AND ALL OF THEIR
COMPONENTS SHALL BE LISTED AND INSTALLED IN ACCORDANCE WITH THEIR LISTING
AND MANUFACTURER'S INSTALLATION INSTRUCTIONS. (CRC R1004.1)
A/C CONDENSER / HEAT PUMP -TO BE IN COMPLIANCE OF SECTION 307.3 OF CPC AS
SELECTED, VERIFY W/. OWNER -SIZE TBD, SEE T-24 ENERGY REPORT FOR MORE INFO –
PROVIDE POWER AND SOUND DAMPENING PAD AS REQ’D. –INSTALL AND MAINTAIN
REQUIRED CLEARANCES PER MFGR. INSTRUCTION
FAU -PROVIDE GAS S.O., POWER, AND VENTING AS REQ'D. BY MFG'R. –INSTALL PER
MFGR. INSTRUCTION
RECESSED MAIN SERVICE PANEL -400 AMP MAX. (MAINTAIN 36" CLEAR FROM FACE
OF PANEL TO ANY OBSTRUCTION) –GC TO COORDINATE W/. UTILITY COMPANY
ROOF/DECK DRAIN -PER CHAPTER 11 OF CPC -SIZE THE DRAIN AND PIPING PER TABLE
1103.1 AND 1103.2 OF CPC –ROOF DRAIN SHALL HAVE DOMED STRAINER (CPC 1102.2) –
REF. DETAIL 11/AD-1.0
OVERFLOW OR EMERGENCY DRAIN -PER CHAPTER 11 OF CPC -COPPER OR EQ., INSTALL
PER MFGR. INSTRUC., SLOPED TOWARD IN-WALL DRAIN INLETS –SLOPE AND SIZE PER
TABLE 1103.3 OF CPC –REF. DTL. 11/AD-1.0
2X4 STUD WALL
2X6 STUD WALL
2X8 STUD WALL
2X10 STUD WALL
EXT. POCKET DOOR WALL - TYP. 2X6 EXT. FRMG. AND 2X4 INTERIOR FRAMING W/.
DOUBLE TOP PLATE AND SINGLE SILL PLATE U.N.O., MIN. AIR SPACE/DOOR POCKET
TO BE VERIFIED W/. DOOR MFGR. - STUDS MIN. SPACING PER STRUCT. AND EXT.
FINISH MFGR. INSTRUCTION AND/OR LISTING –SEE EXT. WALL DETAILS AND STRUCT.
DWGS
CONCRETE WALL -12”REINFORCED CAST IN PLACE CONCRETE WALL TYP. U.N.O. PER
STRUCT., REF. STRCUTC. DWGS. –FOR BASEMENT/RETAINING CONCRETE WALL
PROVIDE WATERPROOFING OR DAMPPROOFING AND DRAINAGE AS REQUIRED PER
SECTION R406.1 & R406.2, REF. SOILS REPORT,WATERPROOFING & DAMPROOFING
NOTES ON SHEET T-1.1 –EXPOSED SURFACES TO HAVE TROWELED SMOOTH FINISH
WITH A LIGHT GRAY COLOR, PROVIDE SAMPLE FOR ARCH. APPROVAL
SLAB/FRAMING DEPRESSION -SEE STRUCT. DWGS. FOR THE RECESSION DETAILS -
FOR RECESSION SPECIFIC TO EQUIPMENT OR ASSEMBLY VERIFY THE REQUIRED
RECESSION W/. MFGR. OR FABRICATOR –SHOWER RECESSION TO BE VERIFIED W/.
I.D.
SEE SHEET AD-2.0 FOR THE TYPICAL DEPRESSION OF DOORS AND WINDOWS, VERIFY
ALL DEPRESSIONS W/. MFGR.
STUDS MIN. SPACING PER STRUCT. AND EXT. FINISH MFGR.
INSTRUCTION AND/OR LISTING –SEE EXT. WALL DETAILS AND
STRUCT. DWGS
VERTICAL STORM DRAIN PIPE IN-WALL / OVERFLOW -MTL. PIPE PER
CHAPTER 11 OF CPC, SIZE PER TABLE 1103.1 (MIN. 2”DIA. PIPE & TYP. 3”DIA. PIPE) –
SEE CIVIL DWGS. FOR TERMINATION DTLS. ABV. OR BLW. GROUND. VERIFY ALL
TERMINATION POINTS, TYPE AND DETAILS W/. CIVIL PRIOR TO POURING THE CONCRETE
SLAB
OVERFLOW
DRAINLINE
A-4.1
A-4.0
A-4.03A-4.1
1
1
2
1
A-5.0
1
A-5.0
3
A-5.0
3
A-5.0
2
A-5.0
2
A-5.0
PWD. 2
MECH. WELL
MECH.
ROOF DECK
SLOPE
2% MIN.SLOPE 2% MIN.
22' - 6 3/4"13' - 5 1/4"22' - 6 3/4"3' - 4"32' - 1 1/4"25
'
-
5
7
/
8
"
17
'
-
6
1
/
4
"
4'
-
1
3
/
8
"
9'
-
1
"
1'
-
1
1
1
/
2
"
1'
-
7
7
/
8
"
5'
-
1
5
/
8
"
8'
-
9
1
/
4
"
13' - 5 1/4"6' - 6 7/8"9' - 5"6' - 6 7/8"3' - 4"
32.52' F.F.
29
28
32.22' T.O.S.
36' - 0"22' - 6 3/4"30' - 5 1/4"
3' - 7 3/8"5' - 3 7/8"2' - 4"2' - 4"5' - 3 7/8"3' - 7 3/8"
2' - 4 3/8"
17
'
-
6
1
/
4
"
4'
-
1
3
/
8
"
9'
-
1
"
3'
-
1
1
3
/
4
"
6
1
/
4
"
6'
-
5
"
2'
-
1
5
/
8
"
1'
-
7
1
/
4
"
2'
-
1
0
3
/
8
"
ROOF LOUNGE
37
30
36343533
32
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
BRANDON ARCHITECTS
ANNOTATION LEGEND
GENERAL NOTESA
B
01/20/2023
THIRD LEVEL
DIMENSION PLAN
MI
L
L
E
R
R
E
S
I
D
E
N
C
E
MR. & MRS. MATTHEW MILLER
22 BAY ISLAND,
NEWPORT BEACH, CA 92661
P: 949.235.9286
millermg123@gmail.com
CDP
22 BAY ISLAND
NEWPORT BEACH, CA 92661
A-2.5
TBD
BRIAN JOWETT
NO. REVISION DATE
1/4" = 1'-0"1 THIRD LEVEL DIMENSION PLAN
DIMENSION NOTE:
ALL DIMS. ARE TO FACE OF STUD (F.O.S.) OR FACE OF SHT'G. (F.O.S.) TYP. U.N.O. EAVE DIMS. ARE FROM FACE OF SHT'G. TO FACE
OF FINISH FASCIA
ENCLOSED ATTIC AND ENCLOSED RAFTER SPACES VENTING NOTES:
1. ENCLOSED ATTIC AND ENCLOSED RAFTER SPACES SHALL HAVE CROSS VENTILATION BY VENTILATION OPENING PROTECTED
AGAINST THE ENTRANCE OF RAIN OR SNOW UNLESS THEY MEET THE REQUIREMENT OF SECTION R806.5 FOR UNVENTED ATTIC
AND UNVENTED ENCLOSED RAFTER ASSEMBLIES. VENTILATION OPENING SHALL HAVE THE LEAST DIMENSION OF 1/16”MIN. AND
1/4”MAX OTHERWISE THE OPENING SHALL HAVE THE CORROSION-RESISTANT WIRE CLOTH SCREENING, HARDWARE CLOTH,
PERFORATED VINYL OR SIMILAR MATERIAL WITH OPENINGS HAVE A LEAST DIMENSION OF 1/16”MIN. AND 1/4”MAX. OPENING IN
ROOF FRAMING MEMBERS SHALL BE PER THE REQUIREMENT OF SECTION R802.7. REQUIRED VENTILATION OPENINGS SHALL
OPEN DIRECTLY TO THE OUTSIDE AIR AND SHALL BE PROTECTED TO PREVENT THE ENTRY OF BIRDS, RODENTS, SNAKES AND
OTHER SIMILAR CREATURES. (R806.1)
2. THE MINIMUM NET FREE VENTILATING AREA SHOULD BE 1/150 OF THE AREA OF THE VENTED SPACE, EXCEPT FOR THE PROJECT
LOCATED IN CLIMATE ZONE 14 OR 16 WITH A CLASS I OR II VAPOR RETARDER AT THE WARM-IN-WINTER SIDE OF THE CEILING
AND WHERE MIN. 40% AND MAX 50% OF THE REQUIRED VENTILATION PROVIDED IN THE UPPER PORTION OF THE ATTIC OR
RAFTER SPACE PER SECTION R806.2 THEN THE MINIMUM NET FREE VENTILATING AREA CAN BE 1/300 OF THE VENTED SPACE.
(R802.2)
3. PROVIDE 1”SPACE BETWEEN THE INSULATION AND THE ROOF SHEATHING WHERE EAVE OR CORNICE VENTS PROVIDE
BLOCKING, BRIDGING AND INSULATION SHALL NOT BLOCK THE FREE FLOW OF AIR. (R806.3)
4. INSTALL VENTILATOR PER MANUFACTURER INSTRUCTION. INSTALL VENTILATOR IN ROOF PER SECTION R903 AND VENTILATOR
IN WALL ASSEMBLIES PER SECTION R703.1.
5. FOR THE ATTIC WITH VERTICAL HEIGHT GREATER THAN OR EQUAL TO 30”(VERTICAL HEIGHT MEASURED FROM THE TOP OF
CEILING JOIST TO THE BOTTOM OF THE ROOF RAFTERS) WITHIN 30S.F. MIN. PROVIDE THE OPENING WITH ROUGH-FRAMED
OPENING OF NOT LESS THAN 22”X30”WHICH SHOULD BE LOCATED IN HALLWAY OR OTHER LOCATION WITH READY ACCESS. IF
THE ACCESS LOCATED IN THE WALL THEN THE WIDTH SHOULD BE 22”AND HEIGHT SHOULD BE 30”MIN. IF LOCATED IN CEILING
THEN THE MIN. UNOBSTRUCTED HEADROOM IN THE ATTIC SHOULD BE 30”FROM THE BOTTOM OF CEILING JOIST AT SOME POINT.
ROOF DRAINAGE:
IF THE PROJECT LOCATED IN THE AREA WITH EXPANSIVE OR COLLAPSIBLE SOILS, WATER RUNOFF FROM ROOFS OF ALL
DWELLINGS SHALL BE DISCHARGED TO THE GROUND SURFACE NOT LESS THAN 5 FEET FROM FOUNDATION WALLS OR TO AN
APPROVED DRAINAGE SYSTEM. (R801.3) -REF.CIVIL DWGS FOR STORM WATER MANAGMENT AND SYSTEM.
WEATHER PROTECTION:
1. ROOF DECKS SHALL BE COVERED WITH APPROVED ROOF COVERINGS SECURED TO THE BUILDING OR STRUCTURE IN
ACCORDANCE WITH THE CHAPTER 9 OF THE CURRENT CRC. ROOF ASSEMBLIES SHALL BE DESIGNED AND INSTALLED IN
ACCORDANCE WITH THE CHAPTER 9 OF CRC AND THE APPROVED MANUFACTURER’S INSTRUCTIONS SUCH THAT THE ROOF
ASSEMBLY SHALL SERVE TO PROTECT THE BUILDING OR STRUCTURE. (R903.1)
2. PROVIDE AND INSTALL FLASHING TO PREVENT ENTRY OF MOISTURE TO WALL AND ROOF ASSEMBLIES THRU THE JOINTS IN
COPINGS, PERMEABLE MATERIAL, AND AT INTERSECTION WITH PARAPET WALLS AND OTHER PENETRATION THRU ROOF. (R903.2)
3. FLASHINGS SHALL BE INSTALLED AT WALL AND ROOF INTERSECTIONS, WHEREVER THERE IS A CHANGE IN ROOF SLOPE OR
DIRECTION AND AROUND ROOF OPENINGS. A FLASHING SHALL BE INSTALLED TO DIVERT THE WATER AWAY FROM WHERE THE
EAVE OF A SLOPED ROOF INTERSECTS A VERTICAL SIDEWALL. WHERE FLASHING IS OF METAL, THE METAL SHALL BE CORROSION
RESISTANT WITH A THICKNESS OF NOT LESS THAN 0.019 INCH (0.5 MM) (NO. 26 GALVANIZED SHEET). (R903.2.1)
4. A CRICKET OR SADDLE SHALL BE INSTALLED ON THE RIDGE SIDE OF ANY CHIMNEY OR PENETRATION MORE THAN 30 INCHES
(762 MM) WIDE AS MEASURED PERPENDICULAR TO THE SLOPE. CRICKET OR SADDLE COVERINGS SHALL BE SHEET METAL OR OF
THE SAME MATERIAL AS THE ROOF COVERING. EXCEPT FOR UNIT SKYLIGHTS INSTALLED IN ACCORDANCE WITH HYPERLINK
"HTTPS://CODES.ICCSAFE.ORG/LOOKUP/CRC2019P1_PT03_CH03_SECR308.6" SECTION R308.6 AND FLASHED IN ACCORDANCE
WITH THE MANUFACTURER’S INSTRUCTIONS SHALL BE PERMITTED TO BE INSTALLED WITHOUT A CRICKET OR SADDLE. (R903.2)
5. PARAPET WALLS SHALL BE PROPERLY COPED WITH NONCOMBUSTIBLE, WEATHERPROOF MATERIALS OF A WIDTH NOT LESS
THAN THE THICKNESS OF THE PARAPET WALL. (R903.3)
6. UNLESS ROOFS ARE SLOPED TO DRAIN OVER ROOF EDGES, ROOF DRAINS SHALL BE INSTALLED AT EACH LOW POINT OF THE
ROOF. IF WATER CAN BE ENTRAPPED WITHIN THE ROOF AREA THEN SECONDARY EMERGENCY OVERFLOW ROOF DRAINS OR
SCUPPERS SHALL BE PROVIDED PER SECTION R903.4.1. (R903.4)
MISC. NOTES:
1. INSTALL ROOF PER ROOFING MFG'R. SPECS & INSTALLATION GUIDELINE
2. ARCH. TO APPV. SIZE, COLOR & PROFILE OF EAVE & RAKE COMPONENTS. G.C. TO PROVIDE MOCK-UPS.
3. UNVENTED ENCLOSED RAFTER ASSEMBLY: NO INTERIOR CLASS I VAPOR RETARDER SHALL BE INSTALLED ON THE CEILING SIDE
(ATTIC FLOOR) OF THE UNVENTED ATTIC ASSEMBLY OR ON THE CEILING SIDE OF THE UNVENTED ENCLOSED ROOF FRAMING
ASSEMBLY.
4. REF. WOOD OR WOODBASE PRODUCT NOTES ON FLOOR PLANS
1
A-5.0
1
A-5.0
3
A-5.0
3
A-5.0
2
A-5.0
2
A-5.0
REFER TO SHEET A-2.2 FOR
ADDITIONAL INFORMATION
ROOF DECK REFER TO SHEET A-2.2 FOR
ADDITIONAL INFORMATION
MECH WELL
5:
1
2
S.Y.S.B.
6'
-
0
"
S.Y.S.B.
6'
-
0
"
F.Y.S.B.
4' - 0"
THIRD FLOOR STRUCTURE SETBACK
15' - 0"
THIRD FLOOR STRUCTURE SETBACK
15' - 0"
R.Y.S.B.
18' - 0"
4'
-
0
"
S.Y.S.B.
8'
-
0
"
4'
-
0
"
S.Y.S.B.
5'
-
0
"
FLAT ROOF SETBACK
8' - 0"
TH
I
R
D
F
L
O
O
R
ST
R
U
C
T
U
R
E
SE
T
B
A
C
K
4'
-
0
"
4'
-
0
"
FLAT ROOF SETBACK
8'
-
0
"
FLAT ROOF SETBACK
8' - 0"
FLAT ROOF SETBACK
8'
-
0
"
FLAT ROOF SETBACK
8'
-
0
"
TH
I
R
D
F
L
O
O
R
ST
R
U
C
T
U
R
E
SE
T
B
A
C
K
TH
I
R
D
F
L
O
O
R
ST
R
U
C
T
U
R
E
SE
T
B
A
C
K
TH
I
R
D
F
L
O
O
R
ST
R
U
C
T
U
R
E
SE
T
B
A
C
K
1
2
2
2
2
2
2
2
3
4
4
3
4
5
6
5
35
3
7
2
2
8
9
8
9
8
10
101
1
1
42.69' RIDGE
42.44' RIDGE
9
11
11
12
12
12
2 12
12
12
12
13
12
14 15
8
16
16
17
1
1
1
1
1
1
1
1
7:12
7:127:12
7:12
6:
1
2
6:1
2
5:12
6:1
2
5:
1
2
6:126:12
4:12
6:12 6:12
4:1
2
4:
1
2
4:
1
2
4:12
4:12
FLAT ROOF SETBACK
8'
-
0
"
212
2
12
12
38.32' RIDGE
41.31'
41.31'
36.11' RIDGE
36.19' RIDGE
36.61' RIDGE
36.35' RIDGE
36.91' RIDGE
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
GENERAL NOTESA
B KEYNOTES
BRANDON ARCHITECTS
01/20/2023
ROOF PLAN
MI
L
L
E
R
R
E
S
I
D
E
N
C
E
MR. & MRS. MATTHEW MILLER
22 BAY ISLAND,
NEWPORT BEACH, CA 92661
P: 949.235.9286
millermg123@gmail.com
CDP
22 BAY ISLAND
NEWPORT BEACH, CA 92661
A-3.0
TBD
BRIAN JOWETT
1 SPANISH TILE - 2-PIECE - COLOR AS SEL., REF. MAT. SCHEDULE SHT. A-4.0
2 DOWNSPOUT - ALUMINUM W/. KYNAR FINISH OR EQUIV. - AS SEL. (ARCH. TO APPROVE)
3 BOUNDARY LINE
4 EASEMENT LINE
5 SIDE YARD SETBACK
6 REAR YARD SETBACK
7 FRONT YARD SETBACK
8 DECK DRAIN - SLOPE 2% MIN. - REF. DTL. 11/AD-1
9 EXTERIOR GUARDRAIL, WROUGHT IRON - MIN. 42" HEIGHT - 4" MAX. SPHERE OPENING, REF. DTL. 4/AD-1
10 BISON DECKING SYSTEM OVER WESTCOAT ALX WATERPROOFING SYSTEM PER ICC# EST - 2201, REF. MAT. SCHED. A/A-4.0.
11 FABRIC AWNING AS SELECTED, ARCH. TO APPROVE
12 GUTTER - ALUMINUM W/. KYNAR FINISH, SHAPE AS SEL. - PROVIDE SHOP DWGS. TO ARCH.
13 JULIET WROUGHT IRON BALCONY, ARCH. TO APPROVE. REF. STRUCT FOR CONNECTION
14 BBQ - VERIFY APPLIANCE W/. OWNER
15 REFRIGERATOR - UNDER-COUNTER, PER I.D. & OWNER
16 CHIMNEY SHALL EXTEND AT LEAST 2' HIGHER THAN ANY PORTION OF THE BUILDING W/IN. 10', BUT SHALL NOT BE LESS THAN
3' ABV. THE HIGHEST POINT WHERE THE CHIMNEY PASSES THRU THE ROOF (CBC 2113.9)
17 STANDING SEAM METAL ROOFING - REF. MAT. SCHEDULE SHT. A-4.0
1/4" = 1'-0"1 ARCHITECTURAL ROOF PLAN
NO. REVISION DATE
FIRST LEVEL F.F.
10.00'
SECOND LEVEL F.F.
22.26'
SECOND LEVEL F.F.
22.26'
THIRD LEVEL FLOOR PLATE
31.31'
THIRD LEVEL FLOOR PLATE
31.31'
FIRST LEVEL FLOOR PLATE
8.79'
SECOND LEVEL FLOOR PLATE
21.05'SECOND LEVEL FLOOR PLATE
21.05'
1
A-5.0
MAX. RIDGE HT.
43.31'
MAX. RIDGE HT.
43.31'
CITY MAX FLAT HT.
38.31'
CITY MAX FLAT HT.
38.31'
GRADE PLANE
10.31'
GRADE PLANE
10.31'
FIRST LEVEL T.O.S.
9.87'
SECOND LEVEL T.O.S.
22.13'
SECOND LEVEL T.O.S.
22.13'
28
'
-
0
"
33
'
-
0
"
2
A-5.0
THIRD LEVEL F.F.
32.52'
THIRD LEVEL F.F.
32.52'
THIRD LEVEL T.O.S.
32.39'
THIRD LEVEL T.O.S.
32.39'
ROOF PLATE
38.83'
ROOF PLATE
38.83'
5:1 2
UPPER FIRST LEVEL F.F.
11.00'
UPPER FIRST LEVEL T.O.S.
10.87'
1'
-
1
"
1
1
/
2
"
3
3
/
4
"
10
'
-
8
7
/
8
"
1'
-
1
"
1
1
/
2
"
9'
-
0
5
/
8
"
3
1
/
2
"
9
1
/
2
"
1
1
/
2
"
6'
-
3
3
/
4
"
12
'
-
3
1
/
8
"
10
'
-
3
1
/
8
"
6'
-
5
1
/
4
"
PLPL
6
3
/
4
"
11
'
-
3
1
/
8
"
10
'
-
3
1
/
8
"
6'
-
5
1
/
4
"
1
1
/
2
"
10
'
-
0
5
/
8
"
1'
-
1
"
1
1
/
2
"
9'
-
0
5
/
8
"
3 1
/
2
"
9
1
/
2
"
1
1
/
2
"
6'
-
3
3
/
4
"
1
2
3
4
3
4
5
18202122
7 6 5 4 3
2 1
SI
L
L
H
T
.
3'
-
0
"
HE
A
D
H
T
.
8'
-
0
"
SI
L
L
H
T
.
3'
-
0
"
HE
A
D
H
T
.
8'
-
0
"
SI
L
L
H
T
.
4'
-
0
"
HE
A
D
H
T
.
8'
-
0
"
SI
L
L
H
T
.
5'
-
0
"
HE
A
D
H
T
.
8'
-
0
"
SI
L
L
H
T
.
5'
-
0
"
HE
A
D
H
T
.
9'
-
0
"
SI
L
L
H
T
.
3'
-
0
"
HE
A
D
H
T
.
9'
-
0
"
SI
L
L
H
T
.
3'
-
0
"
HE
A
D
H
T
.
9'
-
0
"
SI
L
L
H
T
.
4'
-
0
"
HE
A
D
H
T
.
8'
-
0
"
SI
L
L
H
T
.
4'
-
0
"
HE
A
D
H
T
.
8'
-
0
"
SI
L
L
H
T
.
3'
-
0
"
HE
A
D
H
T
.
8'
-
0
"
SI
L
L
H
T
.
3'
-
0
"
HE
A
D
H
T
.
8'
-
0
"
77
PT 1A 10.48'
43.48'
33' MAX SLOPED ROOF
GRADE PLANE INTERPOLATION
35.94' RIDGE
43.70'44.22'
44.76'
45.46'
PT 1D 11.76'
PT 1C 11.22'
PT 1B 10.70'
LOWER ROOF PLATE
31.60'
LOWER ROOF PLATE
31.60'
24' MAX FLAT ABV. NAVD 88 +9'
33.00'
24' MAX FLAT ABV. NAVD 88 +9'
33.00'
2
28' MAX FLAT ROOF
GRADE PLANE INTERPOLATION
40.46'
42.69' RIDGE
39.76'
PT 1E 12.46'
1
1
8
42
"
M
A
X
3'
-
5
"
SI
L
L
H
T
.
4'
-
0
"
HE
A
D
H
T
.
8'
-
0
"
SIL
L
H
T
.
2'
-
6
"
HE
A
D
H
T
.
9'
-
0
"
SI
L
L
H
T
.
4'
-
0
"
HE
A
D
H
T
.
8'
-
0
"
SI
L
L
H
T
.
2'
-
0
"
HE
A
D
H
T
.
8'
-
0
"
SI
L
L
H
T
.
4'
-
0
"
HE
A
D
H
T
.
8'
-
0
"
SI
L
L
H
T
.
2'
-
6
"
HE
A
D
H
T
.
6'
-
0
"
SI
L
L
H
T
.
2'
-
6
"
HE
A
D
H
T
.
6'
-
0
"
SI
L
L
H
T
.
2'
-
6
"
HE
A
D
H
T
.
6'
-
0
"
2'
-
0
"
1'
-
0
"
41.31' T.O. CHIMNEY
39.22'38.70'38.48'
3'
-
0
"
15
16
17191
36 3435 33 32
22
'
-
8
1
/
4
"
36.35' RIDGE
5
9
2
5
6 6
10 11
1213
13
12
13
13
14
15
15
2
WINDOWS & DOORS:
AUTHORIZED DEALER (PRODUCTS LISTED BELOW)
SUPPLIER:ASSOCIATED BUILDING SUPPLY
ADDRESS:STONE MILL DESIGN CENTER 2915 RED HILL AVE., SUITE F104, COSTA MESA, CA 92626
CONTACT:JOE YOUNAN
PHONE:949.872.3319
FAX:206.666.2150
EMAIL:JYOUNAN@ABSCAL.COM
WEB:WWW.ASSOCIATEDBUILDINGSUPPLY.COM
ALUMINUM CLAD WINDOWS & PATIO DOORS
MANUFACTURER: JELD-WEN WINDOWS & DOORS
PRODUCT:CUSTOM COLLECTION
ADDRESS:3250 LAKEPORT BLVD. P.O. BOX 1329; KLAMATH FALLS, OREGON 97601
PHONE:541-885-7412 OR 800-535-3936
FAX:541-884-3331
WEB:WWW.JELD-WEN.COM
MULTI SLIDE DOORS & STOREFRONT
MANUFACTURER:WESTERN WINDOW SYSTEMS
PRODUCT: SERIES 600 & STOREFRONT SYSTEMS
ADDRESS: 5621 S. 25TH ST., PHOENIX, AZ 85040
PHONE: 877.268.1300
WEB: WWW.WESTERNWINDOWSYSTEMS.COM
GARAGE DOORS:
SUPPLIER:RANCH HOUSE DOORS
WEB:WWW.RANCHHOUSEDOORS.COM
STYLE: CUSTOM
MATERIAL: CUSTOM BUILT, WOOD & GLASS
MATERIALS:
STUCCO VENEER:
MANUFACTURER: LA HABRA, PARAEXUSA
ADDRESS:2911 ORANGE-OLIVE RD., ORANGE, CA, 92865
PHONE:714.637.1700
COLOR: WHITE (ARCH TO APPV. SAMPLE)
APPLICATION: THREE-COAT, SMOOTH
CODE:MIN. 7/8" THK. O/. MIN. 2-LAYERS GRADE 'D' PAPER, ICC-ESR 2564
STONE VENEER:
MANUFACTURER: SANDRINE SCOTT COMMODITIES
STONE TYPE: LIMESTONE/HONED (ARCH. TO VERIFY)
THICKNESS: 1"-1.5" NOMINAL
WEIGHT: <10 PSF
COLOR: LT. BEIGE & WHITE, COLOR GROUT TO MATCH
APPLICATION: SQUARED RUBBLE, RUSTIC GROUT (ARCH. TO APPV.)
CODE: ICC ESR -1215
STONE VENEER (ENTRY):
MANUFACTURER: SANDRINE SCOTT COMMODITIES
STONE TYPE: LIMESTONE/HONED (ARCH. TO VERIFY)
THICKNESS: 1"-1.5" NOMINAL
WEIGHT: <10 PSF
COLOR: LT. BEIGE & WHITE, COLOR GROUT TO MATCH
APPLICATION: CUT STONE (ARCH. TO APPV.)
CODE: ICC ESR -1215
CLAY TILE COOL ROOFING: (CLASS 'A')
PRODUCT: TAPERED TWO-PIECE MISSION TILE
MFGR:BORAL ROOFING LLC
ADDRESS:7575 IRVINE CENTER DRIVE, SUITE 100
IRVINE, CA 92618
PHONE:949.756.1605
COLOR: RUSTICA MADER,TO BE APPROVED BY ARCH. & OWNER
CLASS: A -PROVIDE UNDERLAYMENT AS REQUIRED -REF. DTL. X/AD-1.0
CODE:CLASS A ASSEM'LY. ICC ESR-1900
WEIGHT: APPX. 10 PSF
METAL ROOFING (CLASS 'A')
PRODUCT: STANDING SEAM COPPER ROOFING
MFGR:TBD
COLOR: NATURAL, TO BE APPROVED BY ARCH. & OWNER
NOTES: USE CONTINUOUS 16" OR 18" PANS -VERIFY W/. ARCH. SIZE & LOC'N OF SEAMS (NO TRANSVERSE SEAMS)
REF. DTL X/AD-1.0
CODE:CLASS A ASSEM'LY. ICC ESR-1900
GUTTERS:
MATERIAL: METAL -COPPER/ALUM. PAINTED KYNAR
SHAPE: HALF ROUND/SQUARE (5") (VERIFY W/. ARCH.)
WATERPROOF DECK MEMBRANE:
MFGR:WESTCOAT
ADDRESS:4007 LOCKRIDGE STREET, SAN DIEGO, CA 92102
PRODUCT:ALX WALKING DECK (CLASS 'A')
APPLICATION:DECK FINISH SURFACE TO BE NON-COMBUSTIBLE
CODE:ICC # ESR-2201
FLASHING & WEATHERSTRIPPING
PROVIDE CORROSION-RESISTANCE METAL FLASHING PER CBC FOR ALL EXTERIOR FLASHING, MIN. 24 GUAGE COPPER (16 OZ.)
SHEETS U.N.O. IN CBC OR MFGR. INSTALLATION GUIDELINES. ALL METAL IN CONTACTS TO BE OF SIMILAR TYPE TO AVOID
GALVANIC CORROSION. VERIFY W/. ARCHITECT ANY UNCONVENTIONAL ENVELOPE WATERPROOFING AREAS PRIOR TO
INSTALLATION.
FLASHING SHALL BE INSTALLED IN SUCH A MANNER SO AS TO PREVENT MOISTURE FROM ENTERING THE WALL OR TO REDIRECT
THAT MOISTURE TO THE EXTERIOR. FLASHING SHALL BE INSTALLED AT THE PERIMETERS OF EXTERIOR DOOR AND WINDOW
ASSEMBLIES, PENETRATIONS AND TERMINATIONS OF EXTERIOR WALL ASSEMBLIES, EXTERIOR WALL INTERSECTIONS WITH
ROOFS, CHIMNEYS, PORCHES, DECKS, BALCONIES AND SIMILAR PROJECTIONS AND AT BUILT-IN GUTTERS AND SIMILAR
LOCATIONS WHERE MOISTURE COULD ENTER THE WALL. FLASHING WITH PROJECTING FLANGES SHALL BE INSTALLED ON BOTH
SIDES AND THE ENDS OF COPINGS, UNDER SILLS AND CONTINUOUSLY ABOVE PROJECTING TRIM. WHERE SELF-ADHERED
MEMBRANES ARE USED AS FLASHINGS OF FENESTRATION IN WALL ASSEMBLIES, THOSE SELF-ADHERED FLASHINGS SHALL
COMPLY WITH AAMA 711. WHERE FLUID APPLIED MEMBRANES ARE USED AS FLASHING FOR EXTERIOR WALL OPENINGS, THOSE
FLUID APPLIED MEMBRANE FLASHINGS SHALL COMPLY WITH AAMA 714.
1. FENESTRATIONS MUST HAVE TEMPORARY AND PERMANENT LABELS.
2. REF. ROOF PLAN (A-3.0) FOR ALL PLATE HTS. & RIDGE HTS.
SECOND LEVEL F.F.
22.26'
SECOND LEVEL F.F.
22.26'
THIRD LEVEL FLOOR PLATE
31.31'
THIRD LEVEL FLOOR PLATE
31.31'
SECOND LEVEL FLOOR PLATE
21.05'
SECOND LEVEL FLOOR PLATE
21.05'
3
A-5.0
MAX. RIDGE HT.
43.31'
MAX. RIDGE HT.
43.31'
CITY MAX FLAT HT.
38.31'
CITY MAX FLAT HT.
38.31'
GRADE PLANE
10.31'
GRADE PLANE
10.31'
SECOND LEVEL T.O.S.
22.13'
SECOND LEVEL T.O.S.
22.13'
THIRD LEVEL F.F.
32.52'
THIRD LEVEL F.F.
32.52'
THIRD LEVEL T.O.S.
32.39'
THIRD LEVEL T.O.S.
32.39'
ROOF PLATE
38.83'
ROOF PLATE
38.83'
UPPER FIRST LEVEL F.F.
11.00'
UPPER FIRST LEVEL F.F.
11.00'
UPPER FIRST LEVEL T.O.S.
10.87'
UPPER FIRST LEVEL T.O.S.
10.87'
PLPL
33
'
-
0
"
28
'
-
0
"
6'
-
5
1
/
4
"
10
'
-
3
1
/
8
"
11
'
-
3
1
/
8
"
6'
-
3
3
/
4
"
1
1
/
2
"
9
1
/
2
"
3
1
/
2
"
9'
-
0
5
/
8
"
1
1
/
2
"
1'
-
1
"
10
'
-
0
5
/
8
"
1
1
/
2
"
6
3
/
4
"
42.26' RIDGE
2
5
6 6
5
5
52
2
HEAD HT.
8'
-
0
"
HE
A
D
H
T
.
8'
-
0
"
SI
L
L
H
T
.
3'
-
0
"
15 14
8
LOWER ROOF PLATE
31.60'
LOWER ROOF PLATE
31.60'
24' MAX FLAT ABV. NAVD 88 +9'
33.00'
24' MAX FLAT ABV. NAVD 88 +9'
33.00'
1
1
1
37
9
22
'
-
8
1
/
4
"
36.89' RIDGE
SI
L
L
H
T
.
3'
-
0
"
HE
A
D
H
T
.
8'
-
0
"
SI
L
L
H
T
.
2'
-
6
"
HE
A
D
H
T
.
6'
-
6
"
77
33
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
MATERIAL SPECIFICATIONSA
KEYNOTESC
GENERAL NOTESB
BRANDON ARCHITECTS
01/20/2023
EXTERIOR
ELEVATIONS
MI
L
L
E
R
R
E
S
I
D
E
N
C
E
MR. & MRS. MATTHEW MILLER
22 BAY ISLAND,
NEWPORT BEACH, CA 92661
P: 949.235.9286
millermg123@gmail.com
CDP
22 BAY ISLAND
NEWPORT BEACH, CA 92661
A-4.0
TBD
BRIAN JOWETT
1/4" = 1'-0"1 NORTH ELEVATION
1 SPANISH TILE - 2-PIECE - COLOR AS SEL., REF. MAT. SCHEDULE SHT. A-4.0
2 STUCCO FINISH - MIN. 7/8" THK. W/. DIA. LATH, COLOR AS SEL., REF. MAT. SCHEDULE A-4.0
3 EXTERIOR GUARDRAIL, WROUGHT IRON - MIN. 42" HEIGHT - 4" MAX. SPHERE OPENING, REF. DTL. 4/AD-1
4 DOWNSPOUT - ALUMINUM W/. KYNAR FINISH OR EQUIV. - AS SEL. (ARCH. TO APPROVE)
5 SQUARED RUBBLE STONE VENEER - REF. MAT. SCHEDULE SHT. A-4.0
6 WOOD FASCIA - ARCH. TO APPV.
7 6X8 DECO. TIMBER - SHAPED TAIL AS OCCURS (ARCH. TO APPV. PROFILE) CHAMFER EDGES APPX. 1/2", PAINT AS SEL.
8 FABRIC AWNING AS SELECTED, ARCH. TO APPROVE
9 CUT STONE VENEER - REF. MAT. SCHEDULE SHT. A-4.0
10 STONE CAP - ARCH. TO APPV., G.C. TO PROVIDE SAMPLES
11 JULIET WROUGHT IRON BALCONY, ARCH. TO APPROVE. REF. STRUCT FOR CONNECTION
12 GUTTER - ALUMINUM W/. KYNAR FINISH, SHAPE AS SEL. - PROVIDE SHOP DWGS. TO ARCH.
13 4X6 DECO. TIMBER CORBEL - CHAMFER EDGES APPX. 1/2", PAINT AS SEL.
14 CHIMNEY SHALL EXTEND AT LEAST 2' HIGHER THAN ANY PORTION OF THE BUILDING W/IN. 10', BUT SHALL NOT BE LESS THAN
3' ABV. THE HIGHEST POINT WHERE THE CHIMNEY PASSES THRU THE ROOF (CBC 2113.9)
15 RECESSED WALL NICHE - ARCH. TO APPV,. G.C. TO PROVIDE MOCK UP
NO. REVISION DATE
1/4" = 1'-0"3 EAST ELEVATION
WINDOWS & DOORS:
AUTHORIZED DEALER (PRODUCTS LISTED BELOW)
SUPPLIER:ASSOCIATED BUILDING SUPPLY
ADDRESS:STONE MILL DESIGN CENTER 2915 RED HILL AVE., SUITE F104, COSTA MESA, CA 92626
CONTACT:JOE YOUNAN
PHONE:949.872.3319
FAX:206.666.2150
EMAIL:JYOUNAN@ABSCAL.COM
WEB:WWW.ASSOCIATEDBUILDINGSUPPLY.COM
ALUMINUM CLAD WINDOWS & PATIO DOORS
MANUFACTURER: JELD-WEN WINDOWS & DOORS
PRODUCT:CUSTOM COLLECTION
ADDRESS:3250 LAKEPORT BLVD. P.O. BOX 1329; KLAMATH FALLS, OREGON 97601
PHONE:541-885-7412 OR 800-535-3936
FAX:541-884-3331
WEB:WWW.JELD-WEN.COM
MULTI SLIDE DOORS & STOREFRONT
MANUFACTURER:WESTERN WINDOW SYSTEMS
PRODUCT: SERIES 600 & STOREFRONT SYSTEMS
ADDRESS: 5621 S. 25TH ST., PHOENIX, AZ 85040
PHONE: 877.268.1300
WEB: WWW.WESTERNWINDOWSYSTEMS.COM
GARAGE DOORS:
SUPPLIER:RANCH HOUSE DOORS
WEB:WWW.RANCHHOUSEDOORS.COM
STYLE: CUSTOM
MATERIAL: CUSTOM BUILT, WOOD & GLASS
MATERIALS:
STUCCO VENEER:
MANUFACTURER: LA HABRA, PARAEXUSA
ADDRESS:2911 ORANGE-OLIVE RD., ORANGE, CA, 92865
PHONE:714.637.1700
COLOR: WHITE (ARCH TO APPV. SAMPLE)
APPLICATION: THREE-COAT, SMOOTH
CODE:MIN. 7/8" THK. O/. MIN. 2-LAYERS GRADE 'D' PAPER, ICC-ESR 2564
STONE VENEER:
MANUFACTURER: SANDRINE SCOTT COMMODITIES
STONE TYPE: LIMESTONE/HONED (ARCH. TO VERIFY)
THICKNESS: 1"-1.5" NOMINAL
WEIGHT: <10 PSF
COLOR: LT. BEIGE & WHITE, COLOR GROUT TO MATCH
APPLICATION: SQUARED RUBBLE, RUSTIC GROUT (ARCH. TO APPV.)
CODE: ICC ESR -1215
STONE VENEER (ENTRY):
MANUFACTURER: SANDRINE SCOTT COMMODITIES
STONE TYPE: LIMESTONE/HONED (ARCH. TO VERIFY)
THICKNESS: 1"-1.5" NOMINAL
WEIGHT: <10 PSF
COLOR: LT. BEIGE & WHITE, COLOR GROUT TO MATCH
APPLICATION: CUT STONE (ARCH. TO APPV.)
CODE: ICC ESR -1215
CLAY TILE COOL ROOFING: (CLASS 'A')
PRODUCT: TAPERED TWO-PIECE MISSION TILE
MFGR:BORAL ROOFING LLC
ADDRESS:7575 IRVINE CENTER DRIVE, SUITE 100
IRVINE, CA 92618
PHONE:949.756.1605
COLOR: RUSTICA MADER,TO BE APPROVED BY ARCH. & OWNER
CLASS: A -PROVIDE UNDERLAYMENT AS REQUIRED -REF. DTL. X/AD-1.0
CODE:CLASS A ASSEM'LY. ICC ESR-1900
WEIGHT: APPX. 10 PSF
METAL ROOFING (CLASS 'A')
PRODUCT: STANDING SEAM COPPER ROOFING
MFGR:TBD
COLOR: NATURAL, TO BE APPROVED BY ARCH. & OWNER
NOTES: USE CONTINUOUS 16" OR 18" PANS -VERIFY W/. ARCH. SIZE & LOC'N OF SEAMS (NO TRANSVERSE SEAMS)
REF. DTL X/AD-1.0
CODE:CLASS A ASSEM'LY. ICC ESR-1900
GUTTERS:
MATERIAL: METAL -COPPER/ALUM. PAINTED KYNAR
SHAPE: HALF ROUND/SQUARE (5") (VERIFY W/. ARCH.)
WATERPROOF DECK MEMBRANE:
MFGR:WESTCOAT
ADDRESS:4007 LOCKRIDGE STREET, SAN DIEGO, CA 92102
PRODUCT:ALX WALKING DECK (CLASS 'A')
APPLICATION:DECK FINISH SURFACE TO BE NON-COMBUSTIBLE
CODE:ICC # ESR-2201
FLASHING & WEATHERSTRIPPING
PROVIDE CORROSION-RESISTANCE METAL FLASHING PER CBC FOR ALL EXTERIOR FLASHING, MIN. 24 GUAGE COPPER (16 OZ.)
SHEETS U.N.O. IN CBC OR MFGR. INSTALLATION GUIDELINES. ALL METAL IN CONTACTS TO BE OF SIMILAR TYPE TO AVOID
GALVANIC CORROSION. VERIFY W/. ARCHITECT ANY UNCONVENTIONAL ENVELOPE WATERPROOFING AREAS PRIOR TO
INSTALLATION.
FLASHING SHALL BE INSTALLED IN SUCH A MANNER SO AS TO PREVENT MOISTURE FROM ENTERING THE WALL OR TO REDIRECT
THAT MOISTURE TO THE EXTERIOR. FLASHING SHALL BE INSTALLED AT THE PERIMETERS OF EXTERIOR DOOR AND WINDOW
ASSEMBLIES, PENETRATIONS AND TERMINATIONS OF EXTERIOR WALL ASSEMBLIES, EXTERIOR WALL INTERSECTIONS WITH
ROOFS, CHIMNEYS, PORCHES, DECKS, BALCONIES AND SIMILAR PROJECTIONS AND AT BUILT-IN GUTTERS AND SIMILAR
LOCATIONS WHERE MOISTURE COULD ENTER THE WALL. FLASHING WITH PROJECTING FLANGES SHALL BE INSTALLED ON BOTH
SIDES AND THE ENDS OF COPINGS, UNDER SILLS AND CONTINUOUSLY ABOVE PROJECTING TRIM. WHERE SELF-ADHERED
MEMBRANES ARE USED AS FLASHINGS OF FENESTRATION IN WALL ASSEMBLIES, THOSE SELF-ADHERED FLASHINGS SHALL
COMPLY WITH AAMA 711. WHERE FLUID APPLIED MEMBRANES ARE USED AS FLASHING FOR EXTERIOR WALL OPENINGS, THOSE
FLUID APPLIED MEMBRANE FLASHINGS SHALL COMPLY WITH AAMA 714.
1. FENESTRATIONS MUST HAVE TEMPORARY AND PERMANENT LABELS.
2. REF. ROOF PLAN (A-3.0) FOR ALL PLATE HTS. & RIDGE HTS.
FIRST LEVEL F.F.
10.00'
FIRST LEVEL F.F.
10.00'
SECOND LEVEL F.F.
22.26'
SECOND LEVEL F.F.
22.26'
THIRD LEVEL FLOOR PLATE
31.31'
THIRD LEVEL FLOOR PLATE
31.31'
FIRST LEVEL FLOOR PLATE
8.79'
FIRST LEVEL FLOOR PLATE
8.79'
SECOND LEVEL FLOOR PLATE
21.05'
SECOND LEVEL FLOOR PLATE
21.05'
3
A-5.0
MAX. RIDGE HT.
43.31'
MAX. RIDGE HT.
43.31'
CITY MAX FLAT HT.
38.31'
CITY MAX FLAT HT.
38.31'
GRADE PLANE
10.31'
GRADE PLANE
10.31'
FIRST LEVEL T.O.S.
9.87'
FIRST LEVEL T.O.S.
9.87'
SECOND LEVEL T.O.S.
22.13'
SECOND LEVEL T.O.S.
22.13'
THIRD LEVEL F.F.
32.52'
THIRD LEVEL F.F.
32.52'
THIRD LEVEL T.O.S.
32.39'
THIRD LEVEL T.O.S.
32.39'
ROOF PLATE
38.83'
ROOF PLATE
38.83'
1 1
2
PL PL
11
33
'
-
0
"
28
'
-
0
"
6'
-
5
1
/
4
"
10
'
-
3
1
/
8
"
12
'
-
3
1
/
8
"
6'
-
3
3
/
4
"
1 1
/
2
"
9
1
/
2
"
3 1
/
2
"
9'
-
0
5
/
8
"
1 1
/
2
"
1'
-
1
"
11
'
-
0
5
/
8
"
1
1
/
2
"
1'
-
1
"
42.26' RIDGE
3 44
4
29
LOWER ROOF PLATE
31.60'
LOWER ROOF PLATE
31.60'
24' MAX FLAT ABV. NAVD 88 +9'
33.00'
24' MAX FLAT ABV. NAVD 88 +9'
33.00'
5
5
6
11
101041.31' T.O. CHIMNEY
38.32' RIDGE
41.31' T.O. CHIMNEY
9
7
HE
A
D
H
T
.
8'
-
0
"
HE
A
D
H
T
.
6'
-
4
"
1'
-
0
"
2'
-
0
"
1'
-
0
"
2'
-
0
"
HE
A
D
H
T
.
9'
-
0
"
HE
A
D
H
T
.
9'
-
0
"
12
5
13 12
28
11
13
13
13
22
'
-
8
1
/
4
"
FIRST LEVEL F.F.
10.00'
SECOND LEVEL F.F.
22.26'
SECOND LEVEL F.F.
22.26'
THIRD LEVEL FLOOR PLATE
31.31'
THIRD LEVEL FLOOR PLATE
31.31'
FIRST LEVEL FLOOR PLATE
8.79'
SECOND LEVEL FLOOR PLATE
21.05'SECOND LEVEL FLOOR PLATE
21.05'
1
A-5.0
MAX. RIDGE HT.
43.31'
MAX. RIDGE HT.
43.31'
CITY MAX FLAT HT.
38.31'
CITY MAX FLAT HT.
38.31'
GRADE PLANE
10.31'
GRADE PLANE
10.31'FIRST LEVEL T.O.S.
9.87'
SECOND LEVEL T.O.S.
22.13'
SECOND LEVEL T.O.S.
22.13'
2
A-5.0
THIRD LEVEL F.F.
32.52'
THIRD LEVEL F.F.
32.52'
THIRD LEVEL T.O.S.
32.39'
THIRD LEVEL T.O.S.
32.39'
ROOF PLATE
38.83'
ROOF PLATE
38.83'
UPPER FIRST LEVEL F.F.
11.00'
UPPER FIRST LEVEL T.O.S.
10.87'
6:12
HE
A
D
H
T
.
8'
-
0
"
SI
L
L
H
T
.
3'
-
0
"
HE
A
D
H
T
.
11
'
-
0
"
SI
L
L
H
T
.
7'
-
0
"
1
11
2
1 PLPL
2 33
'
-
0
"
28
'
-
0
"
6'
-
5
1
/
4
"
10
'
-
3
1
/
8
"
11
'
-
3
1
/
8
"
6'
-
3
3
/
4
"
1
1
/
2
"
9
1
/
2
"
3 1
/
2
"
9'
-
0
5
/
8
"
1
1
/
2
"
1'
-
1
"
10
'
-
0
5
/
8
"
1 1
/
2
"
6
3
/
4
"
6'
-
5
1
/
4
"
10
'
-
3
1
/
8
"
12
'
-
3
1
/
8
"
6'
-
3
3
/
4
"
1
1
/
2
"
9
1
/
2
"
3
1
/
2
"
9'
-
0
5
/
8
"
1
1
/
2
"
1'
-
1
"
10
'
-
8
7
/
8
"
3 3
/
4
"
1 1
/
2
"
1'
-
1
"
3 3
4
4
SI
L
L
H
T
.
4'
-
0
"
HE
A
D
H
T
.
8'
-
0
"
SIL
L
H
T
.
2'
-
6
"
HE
A
D
H
T
.
8'
-
0
"
SIL
L
H
T
.
2'
-
6
"
HE
A
D
H
T
.
8'
-
0
"
SIL
L
H
T
.
1'
-
5
"
31 30
24
10
3
23
28' MAX FLAT ROOF
GRADE PLANE INTERPOLATION
33' MAX SLOPED ROOF
GRADE PLANE INTERPOLATION
39.69'
6.69'7.17'
10.47'
12.67'
40.17'
45.67'
LOWER ROOF PLATE
31.60'
LOWER ROOF PLATE
31.60'
24' MAX FLAT ABV. NAVD 88 +9'
33.00'
24' MAX FLAT ABV. NAVD 88 +9'
33.00'
2
7 7
2
44
4 4
44
8
99
10
34.69'
35.17'36.17' RIDGE
42.69' RIDGE
36.59' RIDGE
38.47'
40.67'
9.44'
37.44'
42.44'
43.47'
HE
A
D
H
T
.
8'
-
0
"
HE
A
D
H
T
.
8'
-
0
"
42
"
M
A
X
3'
-
5
"
SI
L
L
H
T
.
7'
-
8
"
HE
A
D
H
T
.
12
'
-
8
"
SIL
L
H
T
.
7'
-
2
"
HE
A
D
H
T
.
11
'
-
2
"
SI
L
L
H
T
.
3'
-
0
"
HE
A
D
H
T
.
8'
-
0
"
SI
L
L
H
T
.
3'
-
0
"
HE
A
D
H
T
.
9'
-
0
"
29 28 27
121314
11
26 25
2
41.31' T.O. CHIMNEY
11
11
11
11
11
11
11
2
2 2
2
22
'
-
8
1
/
4
"
2
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
MATERIAL SPECIFICATIONSA
KEYNOTESC
GENERAL NOTESB
BRANDON ARCHITECTS
01/20/2023
EXTERIOR
ELEVATIONS
MI
L
L
E
R
R
E
S
I
D
E
N
C
E
MR. & MRS. MATTHEW MILLER
22 BAY ISLAND,
NEWPORT BEACH, CA 92661
P: 949.235.9286
millermg123@gmail.com
CDP
22 BAY ISLAND
NEWPORT BEACH, CA 92661
A-4.1
TBD
BRIAN JOWETT
1 SQUARED RUBBLE STONE VENEER - REF. MAT. SCHEDULE SHT. A-4.0
2 STUCCO FINISH - MIN. 7/8" THK. W/. DIA. LATH, COLOR AS SEL., REF. MAT. SCHEDULE A-4.0
3 EXTERIOR GUARDRAIL, WROUGHT IRON - MIN. 42" HEIGHT - 4" MAX. SPHERE OPENING, REF. DTL. 4/AD-1
4 DOWNSPOUT - ALUMINUM W/. KYNAR FINISH OR EQUIV. - AS SEL. (ARCH. TO APPROVE)
5 SPANISH TILE - 2-PIECE - COLOR AS SEL., REF. MAT. SCHEDULE SHT. A-4.0
6 COPPER - REF. MAT. SCHEDULE A-4.0
7 WOOD FASCIA - ARCH. TO APPV.
8 FABRIC AWNING AS SELECTED, ARCH. TO APPROVE
9 6X8 DECO. TIMBER - SHAPED TAIL AS OCCURS (ARCH. TO APPV. PROFILE) CHAMFER EDGES APPX. 1/2", PAINT AS SEL.
10 CHIMNEY SHALL EXTEND AT LEAST 2' HIGHER THAN ANY PORTION OF THE BUILDING W/IN. 10', BUT SHALL NOT BE LESS THAN
3' ABV. THE HIGHEST POINT WHERE THE CHIMNEY PASSES THRU THE ROOF (CBC 2113.9)
11 4X6 DECO. TIMBER CORBEL - CHAMFER EDGES APPX. 1/2", PAINT AS SEL.
12 JULIET WROUGHT IRON BALCONY, ARCH. TO APPROVE. REF. STRUCT FOR CONNECTION
13 GUTTER - ALUMINUM W/. KYNAR FINISH, SHAPE AS SEL. - PROVIDE SHOP DWGS. TO ARCH.
NO. REVISION DATE
1/4" = 1'-0"2 WEST ELEVATION
1/4" = 1'-0"1 SOUTH ELEVATION
FIRST LEVEL F.F.
10.00'
FIRST LEVEL F.F.
10.00'
SECOND LEVEL F.F.
22.26'
SECOND LEVEL F.F.
22.26'
THIRD LEVEL FLOOR PLATE
31.31'
THIRD LEVEL FLOOR PLATE
31.31'
FIRST LEVEL FLOOR PLATE
8.79'
FIRST LEVEL FLOOR PLATE
8.79'
SECOND LEVEL FLOOR PLATE
21.05'
SECOND LEVEL FLOOR PLATE
21.05'
3
A-5.0
MAX. RIDGE HT.
43.31'
MAX. RIDGE HT.
43.31'
CITY MAX FLAT HT.
38.31'
CITY MAX FLAT HT.
38.31'
FIRST LEVEL T.O.S.
9.87'
FIRST LEVEL T.O.S.
9.87'
SECOND LEVEL T.O.S.
22.13'
SECOND LEVEL T.O.S.
22.13'
THIRD LEVEL F.F.
32.52'
THIRD LEVEL F.F.
32.52'
THIRD LEVEL T.O.S.
32.39'
THIRD LEVEL T.O.S.
32.39'
ROOF PLATE
38.83'
ROOF PLATE
38.83'
CL
G
H
T
.
9'
-
0
"
PRIMARY CLOSET
MECH.
5:1 2
FOYER
3'
-
7
1
/
4
"
PL
A
T
E
H
T
.
6'
-
5
1
/
4
"
22
'
-
6
1
/
4
"
32
'
-
6
3
/
4
"
CL
G
H
T
.
9'
-
0
"
32
'
-
9
3
/
4
"
3'
-
1
0
1
/
4
"
6'
-
5
1
/
4
"
22
'
-
6
1
/
4
"
23
10
1
LOWER ROOF PLATE
31.60'
LOWER ROOF PLATE
31.60'
24' MAX FLAT ABV. NAVD 88 +9'
33.00'
24' MAX FLAT ABV. NAVD 88 +9'
33.00'
42.69' RIDGE 42.42' RIDGE
RI
D
G
E
H
T
.
9'
-
0
1
/
2
"
CL
G
H
T
.
6'
-
3
3
/
8
"
CL
G
H
T
.
9'
-
0
"
CL
G
H
T
.
11
'
-
0
"
PWD. 1 C.C.DINING
4
1
/
2
"
PL
A
T
E
H
T
.
9'
-
1
0
5
/
8
"
11
"
11
'
-
4
1
/
8
"
PL
A
T
E
H
T
.
6'
-
5
1
/
4
"
4 1
/
2
"
PL
A
T
E
H
T
.
9'
-
1
0
5
/
8
"
12
'
-
3
1
/
8
"
5:12
4:12
4 :1 2
5:12
ROOF LOUNGE
BEDROOM 3
1
6
66
6
8
8
8
9
6
9
9
9
8
9
9
10
10
11
EXTERIOR WALL:
2 x 4 CONST.:R-13 MIN.
2 x 6 CONST. OR LARGER:R-20 MIN.
RAISED FLOOR:R-30 MIN.
ROOF:R-30
NOTES:
1. REF. T-24 REPORT FOR MORE INFORMATION
2. PROVIDE BID FOR INSULATION OF ENTIRE HOME
*TOTAL R-VALUE INCLUDING THE RIDGID AND SPRAYED AIR-IMPERMEABLE INSULATION WHERE OCCURS FOR UNVENTED ASSEMBLY
FIREBLOCKING AND DRAFTSTOPPING SHALL BE INSTALLED TO CUT OFF ALL CONCEALED DRAFT OPENINGS (BOTH VERTICAL AND
HORIZONTAL) AND SHALL FORM AN EFFECTIVE BARRIER BETWEEN FLOORS, BETWEEN A TOP STORY AND A ROOF OR ATTIC SPACE,
AND SHALL SUBDIVIDE ATTIC SPACES, CONCEALED ROOF SPACES AND FLOOR-CEILING ASSEMBLIES. THE INTEGRITY OF ALL FIRE
BLOCKS AND DRAFT STOPS SHALL BE MAINTAINED.
FIRE BLOCKS
FIREBLOCKING SHALL BE PROVIDED IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES, AT
THE CEILING AND FLOOR LEVELS AND AT 10-FOOT INTERVALS BOTH VERTICAL AND HORIZONTAL.
FIRE BLOCK CONSTRUCTION
FIREBLOCKING SHALL CONSIST OF 2 INCHES NOMINAL LUMBER. FIRE BLOCKS MAY ALSO BE OF GYPSUM BOARD, CEMENT FIBER
BOARD, BATTS OR BLANKETS OF MINERAL OR GLASS FIBER, OR OTHER APPROVED MATERIALS INSTALLED IN SUCH A MANNER AS
TO BE SECURELY RETAINED IN PLACE. LOOSE-FILL INSULATION MATERIAL SHALL NOT BE USED.
WALLS HAVING PARALLEL OR STAGGERED STUDS FOR SOUND-TRANSMISSION CONTROL SHALL HAVE FIRE BLOCKS OF BATTS OR
BLANKETS OF MINERAL OR GLASS FIBER OR OTHER APPROVED FLEXIBLE MATERIALS.
DRAFT STOPS
DRAFTSTOPPING SHALL BE PROVIDED IN THE LOCATIONS SET FORTH IN THIS SECTION.
FLOOR-CEILING ASSEMBLIES
DRAFT STOPS SHALL BE INSTALLED IN FLOOR-CEILING ASSEMBLIES OF THE BUILDING. SUCH DRAFT STOPS SHALL BE IN LINE WITH
WALLS SEPARATING INDIVIDUAL DWELLING UNITS FROM EACH OTHER AND FROM OTHER AREAS.
ATTICS
DRAFT STOPS SHALL BE INSTALLED IN THE ATTICS, MANSARDS, OVERHANGS, FALSE FRONTS SET OUT FROM WALLS AND SIMILAR
CONCEALED SPACES OF THIS BUILDING. SUCH DRAFT STOPS SHALL BE ABOVE AND IN LINE WITH THE WALLS SEPARATING
INDIVIDUAL DWELLING UNITS FROM EACH OTHER AND FROM OTHER USES.
DRAFT STOP CONSTRUCTION
DRAFTSTOPPING MATERIALS SHALL NOT BE LESS THAN ½-INCH GYPSUM BOARD, 3/8-INCH WOOD STRUCTURAL PANEL, 3/8-INCH
TYPE 2-M PARTICLEBOARD OR OTHER APPROVED MATERIALS ADEQUATELY SUPPORTED.
OPENINGS IN THE PARTITIONS SHALL BE PROTECTED BY SELF-CLOSING DOORS WITH AUTOMATIC LATCHES CONSTRUCTED AS
REQUIRED FOR THE PARTITIONS.
ROOM TAGROOM NAME
1
A-5.0
1 1
?
1
1
ELEVATION / SECTION INDICATOR
AD-1.0
1 CALL-OUT TAG
10.00'
SPOT ELEVATION
KEYNOTE TAG
REVISION TAG
DOOR / WINDOW / WINDOW WALL TAG
FIRE RATED CEILING ASS'Y -REF. DTLS. 7/AD-1.0
1-HR RATED INT CONDITION -REF. DTLS. 7/AD-1.0
1-HR RATED EXT CONDITION -REF. DTLS. 7/AD-1.0
CONCRETE WALL/PODIUM DECK -PER STRUCT. REF. STRUCT DWGS. –FOR SLAB ON
GRADE PROVIDE BASE PER R506.2.2 AND VAPOR RETARDER PER R506.2.3 W/.
CAPILLARY BREAK
INSULATED BUILDING ENVELOPE -2X STUDS PER PLANS, SEE DIMENSION PLANS FOR
MORE INFO –INSULATION PER INSULATION SCHEDULE AND T-24 ENERGY REPORTS
UNVENTED ROOF ASSEMBLY ROOF FRAMING -PER STRUCT., REF. STRUCT.
DWGS. –UNVENTED ASSEMBLY TO COMPLY W/. SECTION R806.5 OF CRC, AIR-
IMPERMEABLE VALUE PER TABLE R806.5 OF CRC
VENTED ROOF ASSEMBLY ROOF FRAMING -PER STRUCT., REF. STRUCT. DWGS. –
PROVIDE CROSS VENTILATION PER SECTION R806 OF CRC, SEE ROOF PLAN SHEET A-3.0
FOR ATTIC VENT CALC AND MORE INFO
SECOND LEVEL F.F.
22.26'
SECOND LEVEL F.F.
22.26'
THIRD LEVEL FLOOR PLATE
31.31'
THIRD LEVEL FLOOR PLATE
31.31'
SECOND LEVEL FLOOR PLATE
21.05'
SECOND LEVEL FLOOR PLATE
21.05'
3
A-5.0
MAX. RIDGE HT.
43.31'
MAX. RIDGE HT.
43.31'
CITY MAX FLAT HT.
38.31'
CITY MAX FLAT HT.
38.31'
SECOND LEVEL T.O.S.
22.13'
SECOND LEVEL T.O.S.
22.13'
THIRD LEVEL F.F.
32.52'
THIRD LEVEL F.F.
32.52'
THIRD LEVEL T.O.S.
32.39'
THIRD LEVEL T.O.S.
32.39'
ROOF PLATE
38.83'
ROOF PLATE
38.83'
ENTRY
STUDY
UPPER FIRST LEVEL F.F.
11.00'
UPPER FIRST LEVEL F.F.
11.00'
UPPER FIRST LEVEL T.O.S.
10.87'
UPPER FIRST LEVEL T.O.S.
10.87'
CLG. HT.
9'
-
0
"
3'
-
1
0
1
/
4
"
6'
-
5
1
/
4
"
7'
-
1
0
1
/
2
"
2'
-
4
5
/
8
"
11
'
-
3
1
/
8
"
31
'
-
9
3
/
4
"
29
16
SLOPE 2% MIN
LOWER ROOF PLATE
31.60'
LOWER ROOF PLATE
31.60'
24' MAX FLAT ABV. NAVD 88 +9'
33.00'
24' MAX FLAT ABV. NAVD 88 +9'
33.00'
42.42' RIDGE 42.69' RIDGE
31
'
-
6
3
/
4
"
PL
A
T
E
H
T
.
2'
-
4
1
/
8
"
10
'
-
3
1
/
8
"
11
'
-
3
1
/
8
"
ROOF LOUNGE
FOYERSTOR.
54
CL
G
.
H
T
.
10
'
-
0
"
CL
G
.
H
T
.
9'
-
0
"
CL
G
.
H
T
.
9'
-
0
1
/
2
"
CL
G
.
H
T
.
6'
-
3
3
/
8
"
6 :1 2
4 :1 2
4:12
6:12
STAIRS
1
10
10
11
9
6
9
6
6 9 8
12
FIRST LEVEL F.F.
10.00'
SECOND LEVEL F.F.
22.26'
SECOND LEVEL F.F.
22.26'
THIRD LEVEL FLOOR PLATE
31.31'
THIRD LEVEL FLOOR PLATE
31.31'
FIRST LEVEL FLOOR PLATE
8.79'
SECOND LEVEL FLOOR PLATE
21.05'SECOND LEVEL FLOOR PLATE
21.05'
1
A-5.0
MAX. RIDGE HT.
43.31'
MAX. RIDGE HT.
43.31'
CITY MAX FLAT HT.
38.31'
CITY MAX FLAT HT.
38.31'
FIRST LEVEL T.O.S.
9.87'FIRST LEVEL T.O.S.
9.87'
SECOND LEVEL T.O.S.
22.13'
SECOND LEVEL T.O.S.
22.13'
2
A-5.0
THIRD LEVEL F.F.
32.52'
THIRD LEVEL F.F.
32.52'
THIRD LEVEL T.O.S.
32.39'
THIRD LEVEL T.O.S.
32.39'
CL
G
.
H
T
.
11
'
-
0
"
CL
G
.
H
T
.
9'
-
0
"
ROOF PLATE
38.83'
ROOF PLATE
38.83'
DECK
PRIMARY BEDROOMPRIMARY BALCONY
ROOF DECK
CL
G
.
H
T
.
10
'
-
0
"
UPPER FIRST LEVEL F.F.
11.00'
UPPER FIRST LEVEL T.O.S.
10.87'
R @ 0' -6"2
SLOPE
2% MIN.
SLOPE 2% MIN.
SLOPE
2% MIN.
SLOPE
2% MIN.
RD
I
G
E
H
T
.
13
'
-
3
7
/
8
"
CL
G
.
H
T
.
10
'
-
0
"
76
21
21 22
KITCHEN
32.22' FLAT DECK
LOWER ROOF PLATE
31.60'
LOWER ROOF PLATE
31.60'
24' MAX FLAT ABV. NAVD 88 +9'
33.00'
24' MAX FLAT ABV. NAVD 88 +9'
33.00'
CL
G
.
H
T
.
9'
-
0
"
RID
G
E
H
T
.
12
'
-
6
"
36.09' RIDGE
RI
D
G
E
H
T
.
9'
-
0
1
/
2
"
CL
G
.
H
T
.
9'
-
0
"
SLOPE
2% MIN.
SLOPE
2% MIN.
5'
-
3
3
/
4
"
PL
A
T
E
H
T
.
20
'
-
8
3
/
4
"
5'
-
9
3
/
8
"
26
'
-
0
1
/
2
"
42.69' RIDGE
31
'
-
9
3
/
4
"
7'
-
0
5
/
8
"
21
'
-
4
5
/
8
"
28
'
-
5
1
/
4
"
1'
-
0
"
2'
-
0
"
41.31' T.O. CHIMNEY
DINING FOYER
BEDROOM 1
BEDROOM 2
ROOF LOUNGE
MECH. WELL
SUNKEN FIRE PIT
32 33 34 35 36
22 22
1
7
17
36.35' RIDGE
4 :12
6:1 2 6:12
7 :1 2 7:12
42
"
M
A
X
3'
-
5
"
1
2
3
4
5
6
3
4
5
7
10
10
11
11
DATE
REVISIONS
OWNER INFORMATION:
PROJECT STATUS
PLAN CHECK NO.
151 KALMUS DRIVE, SUITE G-1
COSTA MESA, CA 92626
714.754.4040
WWW.BRANDONARCHITECTS.COM
PROJECT CONTACT
THESE DOCUMENTS ARE THE PROPERTY OF BRANDON
ARCHITECTS INC., AND ARE NOT TO BE DUPLICATED,
ALTERED OR UTILIZED IN ANY WAY BY ANY OTHER PARTY
WITHOUT THE EXPRESSED AUTHORIZATION OF BRANDON
ARCHITECTS. ANY UNAUTHORIZED DUPLICATION OR
ALTERATION OF THESE DOCUMENTS BY ANY PARTY IS A
VIOLATION OF BRANDON ARCHITECTS EXPRESSED
COMMON LAW COPYRIGHT AND OTHER PROPERTY
RIGHTS THERETO, AND IS SUBJECT TO FULL CIVIL
LIABILITIES AND PENALTIES. THESE PLANS ARE ALSO NOT
TO BE ASSIGNED TO ANY THIRD PARTY WITHOUT
OBTAINING WRITTEN AUTHORIZATION AND EXPRESSED
PERMISSION BY BRANDON ARCHITECTS, WHO SHALL
THEN BE HELD HARMLESS AND ABSOLVED OF ANY
LIABILITY REGARDING ANY USE OF THESE DOCUMENTS
BY SUCH THIRD PARTY WHETHER DEPICTED OR IMPLIED
HERON.
PROJECT ADDRESS:
FIRE-BLOCKING & DRAFT STOP NOTESA
INSULATION SCHEDULEB
ANNOTATION LEGENDC
KEYNOTESD
BRANDON ARCHITECTS
01/20/2023
BUILDING SECTIONS
MI
L
L
E
R
R
E
S
I
D
E
N
C
E
MR. & MRS. MATTHEW MILLER
22 BAY ISLAND,
NEWPORT BEACH, CA 92661
P: 949.235.9286
millermg123@gmail.com
CDP
22 BAY ISLAND
NEWPORT BEACH, CA 92661
A-5.0
TBD
BRIAN JOWETT
1/4" = 1'-0"1 TRANSVERSE SECTION 1
1 WATERPROOFING TO EXTEND UP TO 14.4' NAVD88.
2 CHIMNEY SHALL EXTEND AT LEAST 2' HIGHER THAN ANY PORTION OF THE BUILDING W/IN. 10', BUT SHALL NOT BE LESS THAN
3' ABV. THE HIGHEST POINT WHERE THE CHIMNEY PASSES THRU THE ROOF (CBC 2113.9)
3 6X8 DECO. TIMBER - SHAPED TAIL AS OCCURS (ARCH. TO APPV. PROFILE) CHAMFER EDGES APPX. 1/2", PAINT AS SEL.
4 WOOD FASCIA - ARCH. TO APPV.
5 EXTERIOR GUARDRAIL, WROUGHT IRON - MIN. 42" HEIGHT - 4" MAX. SPHERE OPENING, REF. DTL. 4/AD-1
6 4X6 DECO. TIMBER CORBEL - CHAMFER EDGES APPX. 1/2", PAINT AS SEL.
7 FABRIC AWNING AS SELECTED, ARCH. TO APPROVE
8 DOWNSPOUT - ALUMINUM W/. KYNAR FINISH OR EQUIV. - AS SEL. (ARCH. TO APPROVE)
9 GUTTER - ALUMINUM W/. KYNAR FINISH, SHAPE AS SEL. - PROVIDE SHOP DWGS. TO ARCH.
10 FLOOR JOISTS - REF. STRUCT.
11 CONCRETE SLAB ON GRADE - REF. STRUCT.
12 STONE CAP - ARCH. TO APPV., G.C. TO PROVIDE SAMPLES
NO. REVISION DATE
1/4" = 1'-0"2 TRANSVERSE SECTION 2
1/4" = 1'-0"3 LONGITUDINAL SECTION