Loading...
HomeMy WebLinkAboutXR2022-2953 - MiscCITY OF NEWPORT BEACH COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION 100 Civic Center Drive I P.O. Box 1768 1 Newport Beach, CA 92658-8915 www.newportbeachca.gov 1 (949) 644-3200 SMOKE DETECTOR AND CARBON MONOXIDE SELF -CERTIFICATION (this certification is to be filled out by the permittee or homeowner) Project Address: 21U400-jD Cam_ Permit Number: Property Owner: Licensed Contractor: Lic #: The State of California now requires that smoke and carbon monoxide detectors must be installed in all residential buildings California Residential Code (CRC) Section R314.1, CRC R315.2 states in part that existing dwellings be "retrofitted with smoke detectors and carbon monoxide detectors. CRC Section R314.3, CRC R315.3 defines required locations. Both boxes below must be checked: ❑❑ Carbon Monoxide Alarm: On the ceiling or wall outside of each separate sleeping area in the immediate vicinity of bedrooms or in each hallway outside of the rooms, and each level of the dwelling. Detectors are also required in bedrooms with gas fired appliances ❑ ❑ Smoke Alarms: Installed in each room used for sleeping purposes, outside each sleeping area, and on each level of the dwelling unit. Retrofitted detectors may be battery operated for buildings where no alterations are performed on the interior. Multiple -purpose alarms (carbon monoxide and smoke alarms) shall comply with all applicable standards and must be approved by the State Fire Marshall. The devices must be installed per manufacturer's specifications. I, the undersigned, hereby certify that I am the permittee or homeowner of the project. 1 further certify that smoke alarms and carbon monoxide alarms are present and test to be functional in all the following locations: Signature: Date: (e t ZU NOTE. This self -certification is only used for projects to the exterior of the structure where access to the interior of the dwelling by the City of Newport Beach Building Inspector is not achieved during the course of construction. Forms\SmokeDetecfmmnACarhnnMnnnvid CnlfCnd nan sns CITY OF NEWPORT BEACH COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION 100 Civic Center Drive ) P.O. Box 1768 1 Newport Beach, CA 92658-8915 www.newportbeachca.gov ) (949) 644-3200 RETROFIT WINDOW/DOOR CHANGE -OUT CRITERIA & INSPECTION REQUIREMENTS PROJECTADDRESS: Z19 64-4r�0 How many WINDOWS are you changing out? 12- z{ _// DOORS: Z CRITERIA FOR RETROFIT WINDOW/DOOR CHANGE -OUT: A. All replacement windows and doors with glass must be dual glazed. B. A permit to replace windows and doors (sliding) may be obtained online through the City's iPermit program only when the following conditions exist: 1. Windows are replaced like for like in size. No increase in window size is allowed to be permitted online. 2. Windows shall be dual glaze complying with the following energy standards: • U-Factor: 0.30 Maximum • Solar Heat Gain Coefficient (SHGC): 0.23 Maximum 3. Windows that provide emergency escape and rescue openings shall be the manufacturer's largest size that will fit in the opening with the following minimum dimensions: • Net Clear Height Opening: 24 in. • Net Clear Width Opening: 20 in. • Minimum Net Clear Grade -Floor Opening: 5.0 sq. ft. (720.0 sq. in.) • Minimum Net Clear Above Grade -Floor Opening: 5.7 sq. ft. (820.8 sq. in.) C. The following locations require safety glazing (tempered or laminated) glass to be etch marked. 1. Glazing in swinging, sliding, fixed, and bi-fold doors. 2. Glazing in windows within 24 in. from doors and less than 60 in. high above the floor or walking surface. 3. Glazing within 5 ft. from pool or spa. 4. Glazing in windows at shower or bathtub and stair landing less than 60 in. above floor. 5. When all of the following occur: Exposed area of individual pane greater than 9 sq. ft-; exposed bottom edge less than 18 in. above the floor; one or more walking surfaces within 36 in. horizontally of the plane of the glazing and the top edge is more than 36 in. above the floor. D. Landing at the required out -swinging egress door shall not be more than 1 y: in. lower than the top of the threshold. The landing's width shall not be less than the door served with a minimum dimension of 36 in. measured in the direction of travel and a slope not to exceed'/ in. to 12 in. (2%)- E- Install or verify smoke and carbon monoxide detectors per CRC R314.1 and R315.2. (See reverse for INSPECTION REQUIREMENTS) FannslRetrofitWintlowllloorChanae-outCntena 1-A-�0 INSPECTION REQUIREMENTS: 1. Window labels shall remain until inspected. 2. Energy labels shall state: • U-Factor: 0.30 Maximum • SHGC: 0.23 Maximum 3. Job site clean of debris. 4. For framed windows in rough openings, the following shall be inspected: • Window Flashing • Exterior Lath 5. Windows that provide emergency escape and rescue openings (bedrooms and basement) shall be the manufacturer's largest size that will fit in the opening with the following minimum dimensions: • Net Clear Height Opening: 24 inches • Net Clear Width Opening: 20 inches • Minimum Net Clear Grade -Floor Opening: 5.0 sq. ft. (720.0 sq. in.) • Minimum Net clear above grade -floor opening: 5.7 sq. ft. (820.8 sq. in.) 6. Only framed windows may be used in rough openings. Note: Retrofit windows may not be used in lieu of a new frame. 7. Safety glazed windows must be used in appropriate locations. 8. Window control devices must comply with ASTM F2090. 9. Smoke and Carbon Monoxide Detectors must be in place at time of final inspection. (Self - certification form is acceptable.) FonnslRetrofindowl0oorChanae-outCritena 1-8-20