Loading...
HomeMy WebLinkAboutPA2022-0249_20230522_Plans_42x30The Stag Bar + Kitchen Occupancy Change 121 + 125 McFadden Place, Newport Beach, CA 92663 DRAWING DIRECTORY PROJECT TEAM VICINITY MAP AMEND USE PERMIT NO. 2018-013 (PA2018-196) TO ALLOW LIVE ENTERTAINMENT AND DANCE FLOOR PROJECT SCOPE ZONING: OCCUPANCY: (E) CONSTRUCTION NO OF STORIES MU-W2 (MIXED USE WATER RELATED) 1st FLOOR - STAG BAR + GRILL: A-2 2nd FLOOR - STAG HOTEL:R-1 PROJECT INFORMATIONDEFERRED SUBMITTALS DISCREPANCIES IN AND OMISSIONS FROM THE PLANS, SPECIFICATIONS, OR OTHER CONTRACT DOCUMENTS, OR QUESTIONS AS TO THEIR MEANING SHALL, AT ONCE, BE BROUGHT TO THE ATTENTION OF THE ARCHITECT. ANY INTERPRETATION OF THE DOCUMENTS WILL BE MADE ONLY BY ADDENDA DULY ISSUED AND A COPY OF SUCH ADDENDA WILL BE MAILED OR DELIVERED TO EACH GENERAL CONTRACTOR BIDDER RECEIVING A SET OF SUCH DOCUMENTS. THE OWNER WILL NOT BE RESPONSIBLE FOR ANY OTHER EXPLANATIONS OR INTERPRETATIONS. SHOULD ANYTHING IN THE SCOPE OF WORK OR ANY OF THE SECTIONS OF THE SPECIFICATIONS BE FOUND TO BE IN ERROR, HAVE CONFLICTS OR DISCREPANCIES, SUCH INFORMATION SHALL BE PROMPTLY BROUGHT TO THE ATTENTION OF THE ARCHITECT IN WRITING DURING THE BID PROCESS, UPON WHICH, THE ARCHITECT WILL ISSUE A BID CLARIFICATION BY ADDENDA. QUESTIONS RECEIVED LESS THAN 48 HOURS BEFORE THE BID OPENING CANNOT BE ANSWERED. NOTWITHSTANDING THAT DRAWINGS AND SPECIFICATIONS MAY BE INCOMPLETE IN CERTAIN DETAILS, IT IS UNDERSTOOD BY CONTRACTOR THAT ANY WORK NOT EXPLICITLY SHOWN OR EXPLICITLY SPECIFIED THEREIN, BUT NONETHELESS REQUIRED TO COMPLY WITH THE AGREED CONTRACTUAL INTENT OF PROVIDING A COMPLETE JOB, SHALL BE INCLUDED IN THE WORK. GENERAL NOTES T0.1 TI T L E S H E E T - PR O J E C T I N F O EXISTING OCC. LOAD CALCULATION 121 + 125 MCFADDEN PLACE NEWPORT BEACH, CA 92663 TYPE V-B (UNREINFORCED MASONRY & WOOD FRAMED), SPRINKLERED W/ 2 HOUR FIRE SEPARATION BETWEEN GROUND FLOOR AND 2ND FLOOR. (EXISTING) T0.1 TITLE SHEET - PROJECT INFO ARCHITECTURAL DRAWINGS 07.25.22 PROJECT ADDRESS ROBINSON HILL ARCHITECTURE, INC. 3195-B AIRPORT LOOP DRIVE COSTA MESA, CALIFORNIA 92626 PHONE: 714.825.8888 CONTACT:MR. ALEX ARIE 121 + 125 MCFADDEN PLACE NEWPORT BEACH, CA 92663 BUILDING OWNER ARCHITECT MCFADDEN PLACE, LLC 3334 E. COAST HWY #418 CORONA DEL MAR, CA 92625 PHONE:949.675.2340 CONTACT:MR. MARIO MAROVIC SHEET TITLEDWG. NUMBER DWG. ISSUE REV #DATE OF ISSUE REVISION DATE PROJECT INFORMATION EXISTING PLUMBING CALCULATIONS INTERPRETATION OF THE DOCUMENTS GOVERNING CODES CAL. BUILDING CODE CAL. MECHANICAL CODE CAL. PLUMBING CODE CAL. ELECTRICAL CODE TITLE 24 ENERGY STANDARDS CAL GREEN BUILDING CODE NOTE: CONSTRUCTION PLANS AND CALCULATIONS SHALL COMPLY W/ ALL OF THE REQ. OF THE CBC 2016 EDITION. 2019 EDITION (2016 IBC) 2019 EDITION (2016 CMC) 2019 EDITION (2016 CPC) 2019 EDITION (2016 NEC) 2019 EDITION 2019 EDITION (CGBC) 2 OCCUPANT LOAD CALCULATION: AREA BUSINESS EXIST. OCC. GROUND FLOOR THE STAG BAR + KITCHEN ALLOWED OCC. PER USE PERMIT CONDITION NO. 12 INTERIOR CUSTOMER OCC. LIMIT : 211 OUTDOOR CUSTOMER OCC. LIMIT : 49 TOTAL CUSTOMER OCC. :260 UPPER FLOOR THE STAG HOTEL 17 EXISTING TO REMAIN NOTE: FOR INFORMATION ON OCCUPANT CALCULATIONS, SEE SHEET A1.1-A1.2 RESTROOM FIXTURE CALCULATION: (PER CPC 2016 TABLE 422.1) 70 OCCUPANTS TOTAL OCC.GENDER W.C. U. LAV. 35 MEN REQ 1 1 1 PROV 1 3 2 35 WOMEN REQ 2 - 1 PROV 3 - 2 NOTE - FOR INFOR. ON OCCUPANT CALCULATIONS, SEE SHEET A1.1-A1.2 A1.0 A1.1 STANDARD OPERATION PROPOSED OCC. LOAD FLOOR PLAN OCCUPANT LOAD CALCULATIONS SUBMITTAL DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE ARCHITECT OR ENGINEER OF RECORD WHO SHALL REVIEW THEM AND FORWARD THEM TO THE BUILDING OFFICIAL WITH A NOTATION INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED AND THAT THEY HAVE BEEN FOUND TO BE IN GENERAL CONFORMANCE WITH THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL ITEMS-SHALL NOT BE INSTALLED UNTIL THEIR DESIGN AND SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING OFFICIAL. NOTE: BUILDING TO BE EQUIPPED WITH AUTOMATIC FIRE SPRINKLER SYSTEM IN ACCORDANCE WITH NFPA 13. 09.27.22 Sheet No.: Date: Job Number: Rev.Description Submittal Dates Owner Date robinson hill architecture, inc. C-23553 C-20731Michael David Robinson: John Steven Hill: Sheet Title Consultant Stamp 22RHA1077.C1 Project Type OC C U P A N T L O A D A S S E S S M E N T 12 1 + 1 2 5 M C F A D D E N P L A C E NE W P O R T B E A C H , C A 9 2 6 6 3 Th e S t a g B a r + K i t c h e n MCFADDEN PLACE, LLC 3334 EAST COAST HIGHWAY, #418 CORONA DEL MAR, CA 92625 ATTN: MARIO MAROVIC 949-675-2340 BUSINESS 949-813-5683 MOBILE 1 Permit Submittal 03.23.23 2 PC RE Submital 05.15.23 07.25.22 07.25.22 07.25.22A1.0a DANCE FLOOR DJ PLAN A 07.25.22 A1.0b DANCE FLOOR DJ PLAN B HOURS OF OPERATION HOURS OF OPERATION : 6:00AM - 2:00AM DAILY PROPOSED LIVE ENTERTAINMENT : 11:00AM - 2:00AM DAILY PROPOSED DANCING : 11:00AM - 2:00AM DAILY A0.0 EXIST. & APPROV. FL PLAN PER USE PERMIT NO. 2018-013 (PA2018-196) A1.2 OCCUPANT LOAD CALCULATIONS 07.25.22 07.25.22 1 05.15.23 2 1 1 03.23.23 03.23.23 FIRE ALARM SYSTEM: BUILDING IS EQUIPPED W/ AN NFPA 72 FIRE ALARM SYSTEM IN COMPLIANCE W/ 907.2.1 OF THE CALIFORNIA FIRE CODE. 2 ELEVATION @ MCFADDEN PLACE 2 05.15.23 2 05.15.23 2 05.15.23 2 05.15.23 2 (E) OPERABLE WINDOWS TO REMAIN (E) DOOR W/ PANIC HARDWARE TO REMAIN PATIO 01 1.5 1.6 1.7 2.0 2.1 2.2 2.4 2.5 3.0 D 01 1.5 1.6 1.7 2.0 2.1 2.2 2.4 2.5 3.0 C B.4 B A.5 A D C B.4 B A.5 A C.9 STAIR #1 0.0 OCC. STAIR #2 0.0 OCC. 78 LF @ 1/2 LF MAIN BAR SEATING 39 OCC. 25.03 LF 12.11 LF 12.11 LFDRY STORAGE OFFICE 2.0 OCC. BEER WALK-IN ICE ELECTRIC 34.3 SF MEN'S 143.2 SF WOMEN'S 159.1 SF JANITOR 7.9 SF 24.14 LF (E) KITCHEN 7.0 OCC. (E) STORAGE 1 OCC. 10.0 LF @ 1/2 LF PATIO SEATING 5 OCC. SERVICE COUNTER 704.48 SF @ 1/5 BAR STANDING TOTAL 141 OCC. 12.11 LF @ 1/2 LF BAR BOOTH (A & B) 6 OCC EA. 45.64 LF @ 2 LF PATIO BOOTH TOTAL 22.0 OCC. 328.57 SF @ 1/15 PATIO DINING TOTAL 22 OCC. 9 OCC. EXIT #H2 (HOTEL ABOVE) 9 O C C . EX I T # H 1 (H O T E L A B O V E ) 142 O C C . EXI T # B 1 142 OCC. EXIT #B2 26 O C C . EXI T # B 3 45.0 SF 45.0 SF 26 OCC. EXIT #B3 234.66 SF EXCLUDED PATH OF TRAVEL NO OCCUPANCY AREA TO BE CLEAR OF ALL OBSTRUCTIONS NOT COMPLYING WITH CBC CHAPTER 11B 5'-0" (E) ADA COUNTER (E) BAR STAFF - 5 OCC. NON PUBLIC B.O.H STAFF 13 CUSTOMER TOTAL 260 PUBLIC AREA EMPLOYEES 17 INTERIOR DINING PUBLIC - 211 OCC. PATIO DINING PULIC - 49 OCC. 76.9 SF 328.57 SF PATIO - 49 OCC. 21 . 5 L F 3'- 8 " (E ) C L E A R P . O . T T O R R . 3'-8" (E) C L E A R P . O . T T O R R . 6'-258" (E) ADA COUNTER 3'-0" SERVER ACCESS 3'- 8 " 3'- 8 " (E) C L E A R P . O . T 357.15 5'-0" (E) ADA COUNTER BAR BOOTH (C) 25.03 LF @ LF 12 OCC. TABLE DINING (AREA C) 76.9 SF @ 1/15 5 OCC. (E) PATIO DOOR W/ PANIC HARDWARE TO REMAIN UNCONCENTRATED BAR OCC. LOAD FACTOR 1/15 S.F. STANDING AREA OCC. LOAD FACTOR 1/5 S.F. BOOTH / BANQUETTE AREA OCC. LOAD FACTOR 1/24" L.F. EGRESS PATH, U.N.O.. NET PUBLIC AREA - SEE PLAN FOR INDIVIDUAL S.F./OCC. FACTOR/NAME (E) ILLUMINESCENT EXIT SIGN WITH EMERGENCY POWER BACK UP SUPPLY. COMPLY PER CBC 1013.3 & 1013.6.3 DJ AREA 1,891.8 SF NET PUBLIC AREA A0.0 EX I S T I N G A P P R O V E D F L O O R SCALE: 1/4" = 1'-0"EXISTING APPROVED FLOOR PLAN PER USE PERMIT NO. 2018-013 (PA2018-196) 01 20 1 8 - 0 1 3 PL A N P E R U S E P E R M I T N O . M C F A D D E N P L A C E PE D E S T R I A N MA L L AL L E Y SCALE: NTSLEGEND 04 SCALE: NTS 03SCALE: NTSKEYNOTES 1.01 PROVIDE A SIGN ABOVE THE DOOR THAT READS 'THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS' PER CBC 1010.1.9.3. 1.02 EXISTING EXIT DOOR TO REMAIN, SEE DETAIL 6B FOR THRESHOLD INFO. 1.03 EXISTING PANIC HARDWARE TO REMAIN 1.04 OCCUPANT LOAD OF 50 OR MORE SHALL HAVE A THE OCCUPANT LOAD OF THE ROOM OR SPACE POSTED IN A CONSPICUOUS PLACE, NEAR THE MAIN EXIT OR EXIT ACCESS DOORWAY FROM THE ROOM OR SPACE. CFC 1004.3 1.05 PROVIDE AN APPROVED AISLE, SEATING, OR FIXED EQUIPMENT DIAGRAM SUSTAINING ANY INCREASE IN OCCUPANT LOAD. SUCH DIAGRAM SHALL BE POSTED IN A CONSPICUOUS PLACE. CBC 1004.2 1.06 EXISTING EXIT SIGN WITH BATTERY BACKUP/EMERGENCY LIGHT TO REMAIN 1.07 EXISTING EMERGENCY LIGHTS WITH BATTERY BACKUP TO REMAIN 1.08 EXISTING PANIC HARDWARE TO BE REMOVED 1.01 1.02 1.02 1.03 1. PROVIDE MEANS OF EGRESS LIGHTING WITH EMERGENCY POWER BACK-UP SUPPLY. CBC 1008.2 (EXISTING) FIRE DEPARTMENT NOTES: 2. ANY ROOM HAVING AN OCCUPANT LOAD OF 50 OR MORE PERSONS WHERE FIXED SEATS ARE NOT INSTALLED, AND WHICH IS USED FOR DINING, DRINKING, OR SIMILAR PURPOSES HAVING AN OCCUPANT LOAD OF 50 OR MORE SHALL HAVE THE OCCUPANT LOAD OF THE ROOM OR SPACE POSTED IN A CONSPICUOUS PLACE, NEAR THE MAIN EXIT OR EXIT ACCESS DOORWAY FROM THE ROOM OR SPACE. POSTED SIGNS SHALL BE OF AN APPROVED LEGIBLE PERMANENT DESIGN AND SHALL BE MAINTAINED BY THE OWNER OF THE OWNER'S AUTHORIZED AGENT. CFC 1004.3. 3. IN THE EVENT OF POWER SUPPLY FAILURE, IN BUILDINGS THAT REQUIRE TWO OR MORE MEANS OF EGRESS, AN EMERGENCY ELECTRICAL SYSTEM SHALL AUTOMATICALLY ILLUMINATE ALL OF THE FOLLOWING AREAS: A.INTERIOR EXIT ACCESS STAIRWAYS AND RAMPS B.INTERIOR AND EXTERIOR EXIT STAIRWAYS AND RAMPS C.EXIT PASSAGEWAYS D.VESTIBULES AND AREAS ON THE LEVEL OF DISCHARGE IN ACCORDANCE WITH SECTION 1028.1 E.EXTERIOR LANDINGS AS REQUIRED BY SECTION 1010.1.6 FOR EXIT DOORWAYS THAT LEAD DIRECTLY TO THE EXIT DISCHARGE. CFC 1008.3.2 4. THE EMERGENCY POWER SYSTEM SHALL PROVIDE POWER FOR A DURATION OF NOT LESS THAN 90 MINUTES AND SHALL CONSIST OF STORAGE BATTERIES, UNIT EQUIPMENT OR ON ON-SITE GENERATOR. CFC 1008.3.4 SCALE: NTSGENERAL NOTES 02 KNEE CLEARANCE THRESHOLD SCALE: NTS 06ACCESSIBILITY DETAILS A B 1.04 1.04 1.05 1.06 1.07 1.07 1.07 1.07 1.08 09.27.22 Sheet No.: Date: Job Number: Rev.Description Submittal Dates Owner Date robinson hill architecture, inc. C-23553 C-20731Michael David Robinson: John Steven Hill: Sheet Title Consultant Stamp 22RHA1077.C1 Project Type OC C U P A N T L O A D A S S E S S M E N T 12 1 + 1 2 5 M C F A D D E N P L A C E NE W P O R T B E A C H , C A 9 2 6 6 3 Th e S t a g B a r + K i t c h e n MCFADDEN PLACE, LLC 3334 EAST COAST HIGHWAY, #418 CORONA DEL MAR, CA 92625 ATTN: MARIO MAROVIC 949-675-2340 BUSINESS 949-813-5683 MOBILE 1 Permit Submittal 03.23.23 2 PC RE Submital 05.15.23 (P A 2 0 1 8 - 1 9 6 ) SCALE: NTS 7 SF. 1.02 1.03 1.04 2 01 1.5 1.6 1.7 2.0 2.1 2.2 2.4 2.5 3.0 D 01 1.5 1.6 1.7 2.0 2.1 2.2 2.4 2.5 3.0 C B.4 B A.5 A D C B.4 B A.5 A C.9 STAIR #1 0.0 OCC. STAIR #2 0.0 OCC. 78 LF @ 1/2 LF MAIN BAR SEATING 39 OCC. 25.03 LF 12.11 LF 12.11 LFDRY STORAGE OFFICE 2.0 OCC. BEER WALK-IN ICE ELECTRIC 34.3 SF MEN'S 143.2 SF WOMEN'S 159.1 SF JANITOR 7.9 SF 24.14 LF (E) KITCHEN 7.0 OCC. (E) STORAGE 1 OCC. 14.5 LF @ 1/2 LF PATIO SEATING 7 OCC. SERVICE COUNTER 689 SF @ 1/5 BAR STANDING TOTAL 138 OCC. 12.11 LF @ 1/2 LF BAR BOOTH (A & B) 6 OCC EA. 45.55 LF @ 2 LF PATIO BOOTH TOTAL 23.0 OCC. 337.74 SF @ 1/15 PATIO DINING TOTAL 23 OCC. 9 OCC. EXIT #H2 (HOTEL ABOVE) 9 O C C . EX I T # H 1 (H O T E L A B O V E ) 150 O C C . EXI T # B 1 151 OCC. EXIT #B2 28 O C C . EX I T # B 3 45.0 SF 45.0 SF 25 OCC. EXIT #B3 PATH OF TRAVEL TO BE CLEAR OF ALL OBSTRUCTIONS TO COMPLY WITH CBC CHAPTER 11B (E) BAR STAFF - 5 OCC. NON PUBLIC B.O.H STAFF 13 CUSTOMER TOTAL 299 PUBLIC AREA EMPLOYEES 17 INTERIOR DINING PUBLIC - 246 OCC. PATIO DINING PUBLIC - 53 OCC. 337.74 SF 21 . 4 1 L F 357.15 3'-8" (E) C L E A R P . O . T T O R R . 6'-258" (E) ADA COUNTER 3'- 8 " (E) C L E A R P . O . T 3' - 8 " 61 SF @ 1/5 12 OCC. 6.1 LF @ 1/2 LF INTERIOR SEATING 3 OCC. SERVICE COUNTER PATIO - 53 OCC. SEE OCC. LOAD CALC. FOR MORE INFO. SEE OCC. LOAD CALC. FOR MORE INFO. SEE OCC. LOAD CALC. FOR MORE INFO. STANDING TOTAL 76.9 SF 300.21 SF 3'- 0 " TABLE DINING (AREA E) 68 SF @ 1/15 5 OCC. TABLE DINING (AREA D) 376 SF @ 1/15 25 OCC. BAR BOOTH (C) 25.03 LF @ LF 12 OCC. 3'-0" SERVER ACCESS 3'- 8 " (E ) C L E A R P . O . T T O R R . 5'-0" (E) ADA COUNTER 5'-0" (E) ADA COUNTER (E) PATIO DOOR W/ PANIC HARDWARE TO REMAIN UNCONCENTRATED BAR OCC. LOAD FACTOR 1/15 S.F. STANDING AREA OCC. LOAD FACTOR 1/5 S.F. BOOTH / BANQUETTE AREA OCC. LOAD FACTOR 1/24" L.F. EGRESS PATH, U.N.O.. NET PUBLIC AREA - SEE PLAN FOR INDIVIDUAL S.F./OCC. FACTOR/NAME (E) ILLUMINESCENT EXIT SIGN WITH EMERGENCY POWER BACK UP SUPPLY. COMPLY PER CBC 1013.3 & 1013.6.3 DJ AREA 1,982.52 SF NET PUBLIC AREA A1.0 PR O P O S E D O C C U P A N C Y SCALE: 1/4" = 1'-0"STANDARD OPERATION PROPOSED OCCUPANT LOAD FLOOR PLAN 01 LO A D F L O O R P L A N M C F A D D E N P L A C E PE D E S T R I A N MA L L AL L E Y SCALE: NTSLEGEND 04 SCALE: NTS 03SCALE: NTSKEYNOTES 1.01 PROVIDE A SIGN ABOVE THE DOOR THAT READS 'THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS' PER CBC 1010.1.9.3. 1.02 EXISTING EXIT DOOR TO REMAIN, SEE DETAIL 6B FOR THRESHOLD INFO. 1.03 EXISTING PANIC HARDWARE TO REMAIN 1.04 OCCUPANT LOAD OF 50 OR MORE SHALL HAVE A THE OCCUPANT LOAD OF THE ROOM OR SPACE POSTED IN A CONSPICUOUS PLACE, NEAR THE MAIN EXIT OR EXIT ACCESS DOORWAY FROM THE ROOM OR SPACE. CFC 1004.3 1.05 PROVIDE AN APPROVED AISLE, SEATING, OR FIXED EQUIPMENT DIAGRAM SUSTAINING ANY INCREASE IN OCCUPANT LOAD. SUCH DIAGRAM SHALL BE POSTED IN A CONSPICUOUS PLACE. CBC 1004.2 1.06 EXISTING EXIT SIGN WITH BATTERY BACKUP/EMERGENCY LIGHT TO REMAIN 1.07 EXISTING EMERGENCY LIGHTS WITH BATTERY BACKUP TO REMAIN 1.08 EXISTING PANIC HARDWARE TO BE REMOVED 1.01 1.02 1.02 1.03 1. PROVIDE MEANS OF EGRESS LIGHTING WITH EMERGENCY POWER BACK-UP SUPPLY. CBC 1008.2 (EXISTING) FIRE DEPARTMENT NOTES: 2. ANY ROOM HAVING AN OCCUPANT LOAD OF 50 OR MORE PERSONS WHERE FIXED SEATS ARE NOT INSTALLED, AND WHICH IS USED FOR DINING, DRINKING, OR SIMILAR PURPOSES HAVING AN OCCUPANT LOAD OF 50 OR MORE SHALL HAVE THE OCCUPANT LOAD OF THE ROOM OR SPACE POSTED IN A CONSPICUOUS PLACE, NEAR THE MAIN EXIT OR EXIT ACCESS DOORWAY FROM THE ROOM OR SPACE. POSTED SIGNS SHALL BE OF AN APPROVED LEGIBLE PERMANENT DESIGN AND SHALL BE MAINTAINED BY THE OWNER OF THE OWNER'S AUTHORIZED AGENT. CFC 1004.3. 3. IN THE EVENT OF POWER SUPPLY FAILURE, IN BUILDINGS THAT REQUIRE TWO OR MORE MEANS OF EGRESS, AN EMERGENCY ELECTRICAL SYSTEM SHALL AUTOMATICALLY ILLUMINATE ALL OF THE FOLLOWING AREAS: A.INTERIOR EXIT ACCESS STAIRWAYS AND RAMPS B.INTERIOR AND EXTERIOR EXIT STAIRWAYS AND RAMPS C.EXIT PASSAGEWAYS D.VESTIBULES AND AREAS ON THE LEVEL OF DISCHARGE IN ACCORDANCE WITH SECTION 1028.1 E.EXTERIOR LANDINGS AS REQUIRED BY SECTION 1010.1.6 FOR EXIT DOORWAYS THAT LEAD DIRECTLY TO THE EXIT DISCHARGE. CFC 1008.3.2 4. THE EMERGENCY POWER SYSTEM SHALL PROVIDE POWER FOR A DURATION OF NOT LESS THAN 90 MINUTES AND SHALL CONSIST OF STORAGE BATTERIES, UNIT EQUIPMENT OR ON ON-SITE GENERATOR. CFC 1008.3.4 SCALE: NTSGENERAL NOTES 02 KNEE CLEARANCE THRESHOLD SCALE: NTS 06ACCESSIBILITY DETAILS A B 1.04 1.04 1.05 1.06 1.07 1.07 1.07 1.07 1 1.08 09.27.22 Sheet No.: Date: Job Number: Rev.Description Submittal Dates Owner Date robinson hill architecture, inc. C-23553 C-20731Michael David Robinson: John Steven Hill: Sheet Title Consultant Stamp 22RHA1077.C1 Project Type OC C U P A N T L O A D A S S E S S M E N T 12 1 + 1 2 5 M C F A D D E N P L A C E NE W P O R T B E A C H , C A 9 2 6 6 3 Th e S t a g B a r + K i t c h e n MCFADDEN PLACE, LLC 3334 EAST COAST HIGHWAY, #418 CORONA DEL MAR, CA 92625 ATTN: MARIO MAROVIC 949-675-2340 BUSINESS 949-813-5683 MOBILE 1 Permit Submittal 03.23.23 2 PC RE Submital 05.15.23 NO R M A L O P E R A T I O N 1 1 1 1 1 1 1 1 1 1.02 1.03 1.04 2 01 1.5 1.6 1.7 2.0 2.1 2.2 2.4 2.5 3.0 D 01 1.5 1.6 1.7 2.0 2.1 2.2 2.4 2.5 3.0 C B.4 B A.5 A D C B.4 B A.5 A C.9 STAIR #1 0.0 OCC. 78 LF @ 1/2 LF MAIN BAR SEATING 39 OCC. 25.03 LF 12.11 LFDRY STORAGE OFFICE 2.0 OCC. BEER WALK-IN ICE ELECTRIC 34.3 SF MEN'S 143.2 SF WOMEN'S 159.1 SF JANITOR 7.9 SF 24.14 LF (E) KITCHEN 7.0 OCC. (E) STORAGE 1 OCC. DJ ALT. 1- 536.40 SF @ 1/5 = BAR STANDING TOTAL 107 OCC. 9 O C C . EXI T # H 1 (H O T E L A B O V E ) (E) BAR STAFF - 5 OCC. PUBLIC AREA EMPLOYEES 17 76.9 SF 6'-258" (E) ADA COUNTER 3'- 8 " 3'- 8 " (E) C L E A R P . O . T 3'- 0 " TEMP. LOCATION FOR POOL TABLES 12.11 LF 12.11 LF @ 1/2 LF BAR BOOTH (A & B) 6 OCC DJ- ALT.1 25 SF 1 OCC. DJ- ALT.2 28.8 SF 1 OCC. NON PUBLIC B.O.H STAFF 13 CUSTOMER TOTAL 296 DJ ALT. 1- INTERIOR DINING PUBLIC - 243 OCC. PATIO DINING PUBLIC - 53 OCC. DJ ALT. 2- INTERIOR DINING PUBLIC - 242 PATIO DINING PUBLIC - 53 OCC. CUSTOMER TOTAL 295 DJ ALT. 2- 561.40 SF @ 1/5 =112 OCC. 149 OCC. - DJ ALT. 1 149 OCC. - DJ ALT. 2 EXIT #B2 PATIO DINING TOTAL 25 OCC. EXIT #B3 45.55 LF @ 2 LF PATIO BOOTH TOTAL 23.0 OCC. 337.74 SF @ 1/15 PATIO DINING TOTAL 23 OCC. 337.74 SF 21 . 4 1 L F 61 SF @ 1/5 STANDING TOTAL 12 OCC. 28 O C C . EXI T # B 3 14.5 LF @ 1/2 LF PATIO SEATING 7 OCC. SERVICE COUNTER 6.1 LF @ 1/2 LF INTERIOR SEATING 3 OCC. SERVICE COUNTER PATIO - 53 OCC. PATH OF TRAVEL TO BE CLEAR OF ALL OBSTRUCTIONS TO COMPLY WITH CBC CHAPTER 11B 3'-0" SERVER ACCESS 5'-0" (E) ADA COUNTER 307 SF 149 O C C . - D J A L T . 1 148 O C C . - D J A L T . 2 EXI T # B 1 5'-0" (E) ADA COUNTER 3' - 0 " DJ - 1 TABLE DINING (AREA D) 384 SF @ 1/15 26 OCC. BAR BOOTH (C) 25.03 LF @ LF 12 OCC. 3'-8" (E) C L E A R P . O . T T O R R . DANCE FLOOR 122.63 SF 25 OCC. TABLE DINING (AREA E) 68 SF @ 1/15 5 OCC. 3'- 8 " (E ) C L E A R P . O . T T O R R . (E) PATIO DOOR W/ PANIC HARDWARE TO REMAIN UNCONCENTRATED BAR OCC. LOAD FACTOR 1/15 S.F. STANDING AREA OCC. LOAD FACTOR 1/5 S.F. BOOTH / BANQUETTE AREA OCC. LOAD FACTOR 1/24" L.F. EGRESS PATH, U.N.O.. NET PUBLIC AREA - SEE PLAN FOR INDIVIDUAL S.F./OCC. FACTOR/NAME (E) ILLUMINESCENT EXIT SIGN WITH EMERGENCY POWER BACK UP SUPPLY. COMPLY PER CBC 1013.3 & 1013.6.3 DJ AREA 1,982.52 SF NET PUBLIC AREA A1.0aSCALE: 1/4" = 1'-0"PROPOSED DANCE FLOOR DJ PLAN A OCCUPANT LOAD W/ POOL TABLES STORED ON SITE 01 M C F A D D E N P L A C E PE D E S T R I A N MA L L AL L E Y SCALE: NTSLEGEND 04 SCALE: NTS 03SCALE: NTSKEYNOTES 1.01 PROVIDE A SIGN ABOVE THE DOOR THAT READS 'THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS' PER CBC 1010.1.9.3. 1.02 EXISTING EXIT DOOR TO REMAIN, SEE DETAIL 6B FOR THRESHOLD INFO. 1.03 EXISTING PANIC HARDWARE TO REMAIN 1.04 OCCUPANT LOAD OF 50 OR MORE SHALL HAVE A THE OCCUPANT LOAD OF THE ROOM OR SPACE POSTED IN A CONSPICUOUS PLACE, NEAR THE MAIN EXIT OR EXIT ACCESS DOORWAY FROM THE ROOM OR SPACE. CFC 1004.3 1.05 PROVIDE AN APPROVED AISLE, SEATING, OR FIXED EQUIPMENT DIAGRAM SUSTAINING ANY INCREASE IN OCCUPANT LOAD. SUCH DIAGRAM SHALL BE POSTED IN A CONSPICUOUS PLACE. CBC 1004.2 1.06 EXISTING EXIT SIGN WITH BATTERY BACKUP/EMERGENCY LIGHT TO REMAIN 1.07 EXISTING EMERGENCY LIGHTS WITH BATTERY BACKUP TO REMAIN 1.08 EXISTING PANIC HARDWARE TO BE REMOVED 1.02 1.01 1.02 1.03 1.02 1.03 1. PROVIDE MEANS OF EGRESS LIGHTING WITH EMERGENCY POWER BACK-UP SUPPLY. CBC 1008.2 (EXISTING) FIRE DEPARTMENT NOTES: 2. ANY ROOM HAVING AN OCCUPANT LOAD OF 50 OR MORE PERSONS WHERE FIXED SEATS ARE NOT INSTALLED, AND WHICH IS USED FOR DINING, DRINKING, OR SIMILAR PURPOSES HAVING AN OCCUPANT LOAD OF 50 OR MORE SHALL HAVE THE OCCUPANT LOAD OF THE ROOM OR SPACE POSTED IN A CONSPICUOUS PLACE, NEAR THE MAIN EXIT OR EXIT ACCESS DOORWAY FROM THE ROOM OR SPACE. POSTED SIGNS SHALL BE OF AN APPROVED LEGIBLE PERMANENT DESIGN AND SHALL BE MAINTAINED BY THE OWNER OF THE OWNER'S AUTHORIZED AGENT. CFC 1004.3. 3. IN THE EVENT OF POWER SUPPLY FAILURE, IN BUILDINGS THAT REQUIRE TWO OR MORE MEANS OF EGRESS, AN EMERGENCY ELECTRICAL SYSTEM SHALL AUTOMATICALLY ILLUMINATE ALL OF THE FOLLOWING AREAS: A.INTERIOR EXIT ACCESS STAIRWAYS AND RAMPS B.INTERIOR AND EXTERIOR EXIT STAIRWAYS AND RAMPS C.EXIT PASSAGEWAYS D.VESTIBULES AND AREAS ON THE LEVEL OF DISCHARGE IN ACCORDANCE WITH SECTION 1028.1 E.EXTERIOR LANDINGS AS REQUIRED BY SECTION 1010.1.6 FOR EXIT DOORWAYS THAT LEAD DIRECTLY TO THE EXIT DISCHARGE. CFC 1008.3.2 4. THE EMERGENCY POWER SYSTEM SHALL PROVIDE POWER FOR A DURATION OF NOT LESS THAN 90 MINUTES AND SHALL CONSIST OF STORAGE BATTERIES, UNIT EQUIPMENT OR ON ON-SITE GENERATOR. CFC 1008.3.4 SCALE: NTSGENERAL NOTES 02 KNEE CLEARANCE THRESHOLD SCALE: NTS 06ACCESSIBILITY DETAILS A B 1.04 1.04 1.04 1.05 1.06 1.07 1.07 1.07 1.07 1.08 09.27.22 Sheet No.: Date: Job Number: Rev.Description Submittal Dates Owner Date robinson hill architecture, inc. C-23553 C-20731Michael David Robinson: John Steven Hill: Sheet Title Consultant Stamp 22RHA1077.C1 Project Type OC C U P A N T L O A D A S S E S S M E N T 12 1 + 1 2 5 M C F A D D E N P L A C E NE W P O R T B E A C H , C A 9 2 6 6 3 Th e S t a g B a r + K i t c h e n MCFADDEN PLACE, LLC 3334 EAST COAST HIGHWAY, #418 CORONA DEL MAR, CA 92625 ATTN: MARIO MAROVIC 949-675-2340 BUSINESS 949-813-5683 MOBILE 1 Permit Submittal 03.23.23 2 PC RE Submital 05.15.23 PL A N A DA N C E F L O O R D J 1 1 1 1 1 1 1 1 1 1 1 2 01 1.5 1.6 1.7 2.0 2.1 2.2 2.4 2.5 3.0 D 01 1.5 1.6 1.7 2.0 2.1 2.2 2.4 2.5 3.0 C B.4 B A.5 A D C B.4 B A.5 A C.9 STAIR #1 0.0 OCC. 78 LF @ 1/2 LF MAIN BAR SEATING 39 OCC. 25.03 LF DRY STORAGE OFFICE 2.0 OCC. BEER WALK-IN ICE ELECTRIC 34.3 SF MEN'S 143.2 SF WOMEN'S 159.1 SF JANITOR 7.9 SF 24.14 LF (E) KITCHEN 7.0 OCC. (E) STORAGE 1 OCC. BAR STANDING TOTAL 9 O C C . EX I T # H 1 (H O T E L A B O V E ) 157 O C C . - D J A L T . 1 156 O C C . D J A L T . 2 EXI T # B 1 5'-0" (E) ADA COUNTER (E) BAR STAFF - 5 OCC. CUSTOMER TOTAL 311 DJ ALT. 1- INTERIOR DINING PUBLIC - 258 OCC. PATIO DINING PUBLIC - 53 OCC. DJ ALT. 2- INTERIOR DINING PUBLIC - 257 PATIO DINING PUBLIC - 53 OCC. 76.9 SF 3'-8" (E) C L E A R P . O . T T O R R . 6'-258" (E) ADA COUNTER 3'-0" SERVER ACCESS 3'- 8 " 3'- 8 " (E) C L E A R P . O . T BAR BOOTH (C) 25.03 LF @ LF 12 OCC. DANCE FLOOR / ENTERMAINMENT 230 SF 46 OCC. 12.11 LF @ 1/2 LF BAR BOOTH (A & B) 6 OCC EA. 12.11 LF 156 OCC. - DJ ALT. 1 156 OCC. - DJ ALT. 2 EXIT #B2 NON PUBLIC B.O.H STAFF 13 CUSTOMER TOTAL 310 DJ ALT. 1 - 513.64 SF @ 1/5 =103 OCC. DJ ALT. 2 - 538.64 SF @ 1/5 =108 OCC. PATIO DINING TOTAL 25 OCC. EXIT #B3 45.55 LF @ 2 LF PATIO BOOTH TOTAL 23.0 OCC. 337.74 SF @ 1/15 PATIO DINING TOTAL 23 OCC. 337.74 SF 21 . 4 1 L F 14.5 LF @ 1/2 LF PATIO SEATING 7 OCC. SERVICE COUNTER 6.1 LF @ 1/2 LF INTERIOR SEATING 3 OCC. SERVICE COUNTER 61 SF @ 1/5 STANDING TOTAL 12 OCC. 28 O C C . EXI T # B 3 PATH OF TRAVEL TO BE CLEAR OF ALL OBSTRUCTIONS TO COMPLY WITH CBC CHAPTER 11B 3'- 0 " DJ-ALT. 2 28.8 SF 1 OCC. 5'-0" (E) ADA COUNTER PATIO - 53 OCC. PUBLIC AREA EMPLOYEES 17 DJ - 1 DJ- ALT.1 25 SF 1 OCC. 300.21 SF TABLE DINING (AREA E) 68 SF @ 1/15 5 OCC. 3'- 8 " (E ) C L E A R P . O . T T O R R . TABLE DINING (AREA D) 376 SF @ 1/15 25 OCC. (E) PATIO DOOR W/ PANIC HARDWARE TO REMAIN UNCONCENTRATED BAR OCC. LOAD FACTOR 1/15 S.F. STANDING AREA OCC. LOAD FACTOR 1/5 S.F. BOOTH / BANQUETTE AREA OCC. LOAD FACTOR 1/24" L.F. EGRESS PATH, U.N.O.. NET PUBLIC AREA - SEE PLAN FOR INDIVIDUAL S.F./OCC. FACTOR/NAME (E) ILLUMINESCENT EXIT SIGN WITH EMERGENCY POWER BACK UP SUPPLY. COMPLY PER CBC 1013.3 & 1013.6.3 DJ AREA 1,982.52 SF NET PUBLIC AREA A1.0bSCALE: 1/4" = 1'-0"01 M C F A D D E N P L A C E PE D E S T R I A N MA L L AL L E Y 1.02 1.01 1.02 1.03 1.02 1.03 KNEE CLEARANCE THRESHOLD SCALE: NTS 06ACCESSIBILITY DETAILS A B 1.04 1.04 1.04 1.05 1.06 1.07 1.07 1.07 1.07 1.08 09.27.22 Sheet No.: Date: Job Number: Rev.Description Submittal Dates Owner Date robinson hill architecture, inc. C-23553 C-20731Michael David Robinson: John Steven Hill: Sheet Title Consultant Stamp 22RHA1077.C1 Project Type OC C U P A N T L O A D A S S E S S M E N T 12 1 + 1 2 5 M C F A D D E N P L A C E NE W P O R T B E A C H , C A 9 2 6 6 3 Th e S t a g B a r + K i t c h e n MCFADDEN PLACE, LLC 3334 EAST COAST HIGHWAY, #418 CORONA DEL MAR, CA 92625 ATTN: MARIO MAROVIC 949-675-2340 BUSINESS 949-813-5683 MOBILE 1 Permit Submittal 03.23.23 2 PC RE Submital 05.15.23 POOL TABLES MOVED TO OFF SITE STORAGE PL A N B DA N C E F L O O R D J SCALE: NTSLEGEND 04 SCALE: NTS 03SCALE: NTSKEYNOTES 1.01 PROVIDE A SIGN ABOVE THE DOOR THAT READS 'THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS' PER CBC 1010.1.9.3. 1.02 EXISTING EXIT DOOR TO REMAIN, SEE DETAIL 6B FOR THRESHOLD INFO. 1.03 EXISTING PANIC HARDWARE TO REMAIN 1.04 OCCUPANT LOAD OF 50 OR MORE SHALL HAVE A THE OCCUPANT LOAD OF THE ROOM OR SPACE POSTED IN A CONSPICUOUS PLACE, NEAR THE MAIN EXIT OR EXIT ACCESS DOORWAY FROM THE ROOM OR SPACE. CFC 1004.3 1.05 PROVIDE AN APPROVED AISLE, SEATING, OR FIXED EQUIPMENT DIAGRAM SUSTAINING ANY INCREASE IN OCCUPANT LOAD. SUCH DIAGRAM SHALL BE POSTED IN A CONSPICUOUS PLACE. CBC 1004.2 1.06 EXISTING EXIT SIGN WITH BATTERY BACKUP/EMERGENCY LIGHT TO REMAIN 1.07 EXISTING EMERGENCY LIGHTS WITH BATTERY BACKUP TO REMAIN 1.08 EXISTING PANIC HARDWARE TO BE REMOVED 1. PROVIDE MEANS OF EGRESS LIGHTING WITH EMERGENCY POWER BACK-UP SUPPLY. CBC 1008.2 (EXISTING) FIRE DEPARTMENT NOTES: 2. ANY ROOM HAVING AN OCCUPANT LOAD OF 50 OR MORE PERSONS WHERE FIXED SEATS ARE NOT INSTALLED, AND WHICH IS USED FOR DINING, DRINKING, OR SIMILAR PURPOSES HAVING AN OCCUPANT LOAD OF 50 OR MORE SHALL HAVE THE OCCUPANT LOAD OF THE ROOM OR SPACE POSTED IN A CONSPICUOUS PLACE, NEAR THE MAIN EXIT OR EXIT ACCESS DOORWAY FROM THE ROOM OR SPACE. POSTED SIGNS SHALL BE OF AN APPROVED LEGIBLE PERMANENT DESIGN AND SHALL BE MAINTAINED BY THE OWNER OF THE OWNER'S AUTHORIZED AGENT. CFC 1004.3. 3. IN THE EVENT OF POWER SUPPLY FAILURE, IN BUILDINGS THAT REQUIRE TWO OR MORE MEANS OF EGRESS, AN EMERGENCY ELECTRICAL SYSTEM SHALL AUTOMATICALLY ILLUMINATE ALL OF THE FOLLOWING AREAS: A.INTERIOR EXIT ACCESS STAIRWAYS AND RAMPS B.INTERIOR AND EXTERIOR EXIT STAIRWAYS AND RAMPS C.EXIT PASSAGEWAYS D.VESTIBULES AND AREAS ON THE LEVEL OF DISCHARGE IN ACCORDANCE WITH SECTION 1028.1 E.EXTERIOR LANDINGS AS REQUIRED BY SECTION 1010.1.6 FOR EXIT DOORWAYS THAT LEAD DIRECTLY TO THE EXIT DISCHARGE. CFC 1008.3.2 4. THE EMERGENCY POWER SYSTEM SHALL PROVIDE POWER FOR A DURATION OF NOT LESS THAN 90 MINUTES AND SHALL CONSIST OF STORAGE BATTERIES, UNIT EQUIPMENT OR ON ON-SITE GENERATOR. CFC 1008.3.4 SCALE: NTSGENERAL NOTES 02 PROPOSED DANCE FLOOR DJ PLAN B OCCUPANT LOAD W/ POOL TABLES STORED OFF SITE 1 1 1 1 1 1 1 1 1 1 1 1 2 09.27.22 Sheet No.: Date: Job Number: Rev.Description Submittal Dates Owner Date robinson hill architecture, inc. C-23553 C-20731Michael David Robinson: John Steven Hill: Sheet Title Consultant Stamp 22RHA1077.C1 Project Type OC C U P A N T L O A D A S S E S S M E N T 12 1 + 1 2 5 M C F A D D E N P L A C E NE W P O R T B E A C H , C A 9 2 6 6 3 Th e S t a g B a r + K i t c h e n MCFADDEN PLACE, LLC 3334 EAST COAST HIGHWAY, #418 CORONA DEL MAR, CA 92625 ATTN: MARIO MAROVIC 949-675-2340 BUSINESS 949-813-5683 MOBILE 1 Permit Submittal 03.23.23 2 PC RE Submital 05.15.23 OC C U P A N T L O A D C A L C S . ST A G B A R + K I T C H E N A1.1NORMAL OPERATION PROPOSED OCCUPANT LOAD & PLUMB CALCS. - PER PLAN A1.0 EXISTING & APPROVED OCCUPANT LOAD & PLUMB. CALCS. PER USE PERMIT # 2018-013 (PA2018-196) PLUMBING FIXTURE CALCULATIONS THE STAG BAR + KITCHEN (Ground Floor) EXISTING OCCUPANCY LOAD CALC. CPC Table 422.1 UNIT #DESCRIPTION USE AREA LENGTH OCC. FACTOR OCC. LOAD Type Area Ratio Occ. BAR BAR STANDING 704.48 sf 1/5 sf 141 A-2 1,891.83 30 64.0 BAR SEATS 147.30 sf 78.00 lf 1/2 lf 39 A-2 -15 0.0 DINING TABLE DINING C 76.90 sf 1/15 sf 5 KITCHEN 1,047.00 200 5.7 BAR BOOTH A 27.83 sf 12.11 lf 1/2 lf 6 B -200 0.0 BAR BOOTH B 27.83 sf 12.11 lf 1/2 lf 6 BAR BOOTH C 49.10 sf 25.03 lf 1/2 lf 12 TOTAL 70.0 PATIO DINING TABLE DINING 328.57 sf 1/15 sf 22 BOOTH SEATING 88.40 sf 45.64 lf 1/2 lf 22 Occupants SERVICE CTR.COUNTER SEATS 31.30 10.00 lf 1/2 lf 5 TOTALS 260 35.0 M 1 WC, 1 U & 1 Lav 1:1-50; 1:1-200; 1:1-150 PUBLIC AREA EMPLOYEES OFFICE GENERAL MANAGER 1 35.0 F 2 WC & 1 Lav AST. GENERAL MANAGER 1 PUBLIC AREA STAFF SECURITY 6 Required Provided ADA BUS BOY 2 M-WC 1 1 1 SERVERS 5 M-U 1 3 1 HOSTESS 2 M-L 1 2 1 TOTALS 17 W-WC 2 3 1 W-L 1 2 1 EXISTING KITCHEN AND BAR STAFF OCCUPANTS TO REMAIN TOTALS 13 MISC AREAS NOT INCLD. IN OCC. LOAD CALCS 1,114.63 sf 0 UNOBSTRUCTED PATH OF TRAVEL 234.66 sf 0 TOTAL GROUND FLOOR OCCUPANCY 290 THE STAG HOTEL (Second Floor) EXISTING RESIDENTIAL OCCUPANTS TO REMAIN TOTALS 17 PLUMBING FIXTURE CALCULATIONS THE STAG BAR + KITCHEN (Ground Floor) - STANDARD OPERATION PROPOSED OCC. LOAD PLAN A1.0 CPC Table 422.1 UNIT #DESCRIPTION USE AREA LENGTH OCC. FACTOR OCC. LOAD Type Area Ratio Occ. A-2 1,982.52 30 67.0 BAR BAR STANDING 749.80 sf 1/5 sf 150 A-2 -15 0.0 BAR SEATS 147.30 sf 78.00 lf 1/2 lf 39 KITCHEN 1,047.00 200 5.7 DINING TABLE DINING D 376.00 sf 1/15 sf 25 B 69.20 200 1.0 TABLE DINING E 68.00 sf 1/15 sf 5 BAR BOOTH A 27.83 sf 12.11 lf 1/2 lf 6 TOTAL 74.0 BAR BOOTH B 27.83 sf 12.11 lf 1/2 lf 6 BAR BOOTH C 49.10 sf 25.03 lf 1/2 lf 12 COUNTER SEATS 6.1 lf 1/2 lf 3 Occupants PATIO DINING TABLE DINING 337.74 sf 1/15 sf 23 BOOTH SEATING 87.24 sf 45.55 lf 1/2 lf 23 37.0 M 1 WC, 1 U & 1 Lav SERVICE CTR.COUNTER SEATS 14.50 lf 1/2 lf 7 1:1-50; 1:1-200; 1:1-150 TOTALS 299 37.0 F 2 WC & 1 Lav PUBLIC AREA EMPLOYEES OFFICE GENERAL MANAGER 1 Required Provided ADA AST. GENERAL MANAGER 1 M-WC 1 1 1 PUBLIC AREA STAFF SECURITY 6 M-U 1 3 1 BUS BOY 2 M-L 1 2 1 SERVERS 5 W-WC 2 3 1 HOSTESS 2 W-L 1 2 1 TOTALS 17 EXISTING KITCHEN AND BAR STAFF OCCUPANTS TO REMAIN TOTALS 13 TOTAL GROUND FLOOR OCCUPANCY 329 THE STAG HOTEL (Second Floor) EXISTING RESIDENTIAL OCCUPANTS TO REMAIN TOTALS 17 1 1 A1.2PROPOSED PLAN A OCC. LOAD & PLUMB. CALCS. POOL TABLES STORED ON SITE - REFER TO PLAN A1.0a 09.27.22 Sheet No.: Date: Job Number: Rev.Description Submittal Dates Owner Date robinson hill architecture, inc. C-23553 C-20731Michael David Robinson: John Steven Hill: Sheet Title Consultant Stamp 22RHA1077.C1 Project Type OC C U P A N T L O A D A S S E S S M E N T 12 1 + 1 2 5 M C F A D D E N P L A C E NE W P O R T B E A C H , C A 9 2 6 6 3 Th e S t a g B a r + K i t c h e n MCFADDEN PLACE, LLC 3334 EAST COAST HIGHWAY, #418 CORONA DEL MAR, CA 92625 ATTN: MARIO MAROVIC 949-675-2340 BUSINESS 949-813-5683 MOBILE 1 Permit Submittal 03.23.23 2 PC RE Submital 05.15.23 OC C U P A N T L O A D C A L C S . ST A G B A R + K I T C H E N PROPOSED PLAN B OCC. LOAD & PLUMB. CALCS. POOL TABLES STORED OFF SITE - REFER TO PLAN A1.0b 1 1 PLUMBING FIXTURE CALCULATIONS THE STAG BAR + KITCHEN (Ground Floor) - PROPOSED DANCE FLOOR DJ PLAN A OCC. LOAD POOL TABLES STORED ON SITE - A1.0a DJ-ALT. 2 DJ-ALT.1 CPC Table 422.1 UNIT #DESCRIPTION USE AREA LENGTH OCC. FACTOR OCC. LOAD OCC. LOAD Type Area Ratio Occ. A-2 1,847.95 30 62.0 BAR BAR STANDING 597.40 sf 1/5 sf 120 BAR SEATS 147.30 sf 78.00 lf 1/2 lf 39 A-2 122.63 15 8.2 ENTERNAINENT DANCE FLOOR STANDING 122.63 sf 1/5 sf 25 KITCHEN 1,047.00 200 5.7 DJ -ALT. 1 26.14 sf 1/200 sf 1 B 69.20 200 1.0 DINING TABLE DINING D 384.00 sf 1/15 sf 26 TABLE DINING E 68.00 sf 1/15 sf 5 TOTAL 77.0 BAR BOOTH A 27.83 sf 12.11 lf 1/2 lf 6 BAR BOOTH B 27.83 sf 12.11 lf 1/2 lf 6 BAR BOOTH C 49.10 sf 25.03 lf 1/2 lf 12 COUNTER SEATS 6.1 lf 1/2 lf 3 Occupants PATIO DINING TABLE DINING 337.74 sf 1/15 sf 23 BOOTH SEATING 87.24 sf 45.55 lf 1/2 lf 23 39.0 M 1 WC, 1 U & 1 Lav SERVICE CTR.COUNTER SEATS 14.50 lf 1/2 lf 7 1:1-50; 1:1-200; 1:1-150 TOTALS 296 39.0 F 2 WC & 1 Lav Required Provided ADA BAR BAR STANDING 622.40 sf 1/5 sf 125 M-WC 1 1 1 BAR SEATS 147.30 sf 78.00 lf 1/2 lf 39 ENTERNAINENT DANCE FLOOR STANDING 122.63 sf 1/5 sf 25 M-U 1 3 1 DJ -ALT. 2 28.87 sf 1/200 sf 1 M-L 1 2 1 DINING TABLE DINING D 384.00 sf 1/15 sf 26 W-WC 2 3 1 TABLE DINING E 68.00 sf 1/15 sf 5 W-L 1 2 1 BAR BOOTH A 27.83 sf 12.11 lf 1/2 lf 6 BAR BOOTH B 27.83 sf 12.11 lf 1/2 lf 0 BAR BOOTH C 49.10 sf 25.03 lf 1/2 lf 12 COUNTER SEATS 6.1 lf 1/2 lf 3 PATIO DINING TABLE DINING 337.74 sf 1/15 sf 23 BOOTH SEATING 87.24 sf 45.55 lf 1/2 lf 23 SERVICE CTR.COUNTER SEATS 14.50 lf 1/2 lf 7 TOTALS 295 PUBLIC AREA EMPLOYEES OFFICE GENERAL MANAGER 1 1 AST. GENERAL MANAGER 1 1 PUBLIC AREA STAFF SECURITY 6 6 BUS BOY 2 2 SERVERS 5 5 HOSTESS 2 2 TOTALS 17 17 EXISTING KITCHEN AND BAR STAFF OCCUPANTS TO REMAIN TOTALS 13 13 TOTAL GROUND FLOOR OCCUPANCY 325 326 THE STAG HOTEL (Second Floor) EXISTING RESIDENTIAL OCCUPANTS TO REMAIN TOTALS 17 PLUMBING FIXTURE CALCULATIONS THE STAG BAR + KITCHEN (Ground Floor) - PROPOSED DANCE FLOOR DJ PLAN B OCC. LOAD POOL TABLES STORED OFF SITE - A1.0b DJ-ALT. 2 DJ-ALT.1 CPC Table 422.1 UNIT #DESCRIPTION USE AREA LENGTH OCC. FACTOR OCC. LOAD OCC. LOAD Type Area Ratio Occ. A-2 1,731.82 30 58.0 BAR BAR STANDING 574.64 sf 1/5 sf 115 BAR SEATS 147.30 sf 78.00 lf 1/2 lf 39 A-2 230.00 15 15.3 ENTERNAINENT DANCE FLOOR STANDING 230.00 sf 1/5 sf 46 KITCHEN 1,047.00 200 5.7 DJ -ALT. 1 25.00 sf 1/200 sf 1 B 69.20 200 1.0 DINING TABLE DINING D 376.00 sf 1/15 sf 25 TABLE DINING E 68.00 sf 1/15 sf 5 TOTAL 81.0 BAR BOOTH A 27.83 sf 12.11 lf 1/2 lf 6 BAR BOOTH B 27.83 sf 12.11 lf 1/2 lf 6 BAR BOOTH C 49.10 sf 25.03 lf 1/2 lf 12 COUNTER SEATS 6.1 lf 1/2 lf 3 Occupants PATIO DINING TABLE DINING 337.74 sf 1/15 sf 23 BOOTH SEATING 87.24 sf 45.55 lf 1/2 lf 23 41.0 M 1 WC, 1 U & 1 Lav SERVICE CTR.COUNTER SEATS 14.50 lf 1/2 lf 7 1:1-50; 1:1-200; 1:1-150 TOTALS 311 41.0 F 2 WC & 1 Lav Required Provided ADA M-WC 1 1 1 BAR BAR STANDING 599.64 sf 1/5 sf 120 BAR SEATS 147.30 sf 78.00 lf 1/2 lf 39 M-U 1 3 1 ENTERNAINENT DANCE FLOOR STANDING 230.00 sf 1/5 sf 46 M-L 1 2 1 DJ -ALT. 2 28.87 sf 1/200 sf 1 W-WC 2 3 1 DINING TABLE DINING D 376.00 sf 1/15 sf 25 W-L 1 2 1 TABLE DINING E 68.00 sf 1/15 sf 5 BAR BOOTH A 27.83 sf 12.11 lf 1/2 lf 6 BAR BOOTH B 27.83 sf 12.11 lf 1/2 lf 0 BAR BOOTH C 49.10 sf 25.03 lf 1/2 lf 12 COUNTER SEATS 6.1 lf 1/2 lf 3 PATIO DINING TABLE DINING 337.74 sf 1/15 sf 23 BOOTH SEATING 87.24 sf 45.64 lf 1/2 lf 23 SERVICE CTR.COUNTER SEATS 14.50 lf 1/2 lf 7 TOTALS 310 PUBLIC AREA EMPLOYEES OFFICE GENERAL MANAGER 1 1 AST. GENERAL MANAGER 1 1 PUBLIC AREA STAFF SECURITY 6 6 BUS BOY 2 2 SERVERS 5 5 HOSTESS 2 2 TOTALS 17 17 EXISTING KITCHEN AND BAR STAFF OCCUPANTS TO REMAIN TOTALS 13 13 TOTAL GROUND FLOOR OCCUPANCY 340 341 THE STAG HOTEL (Second Floor) EXISTING RESIDENTIAL OCCUPANTS TO REMAIN TOTALS 17 1 1 1 1 A2.0SCALE: N.T.SEXISTING - STAG BAR + KITCHEN - REFERENCE FLOOR PLAN 01 ST A G B A R + K I T C H E N RE F E R E N C E F L O O R P L A N (F O R R E F E R E N C E O N L Y ) NOT A PART 09.27.22 Sheet No.: Date: Job Number: Rev.Description Submittal Dates Owner Date robinson hill architecture, inc. C-23553 C-20731Michael David Robinson: John Steven Hill: Sheet Title Consultant Stamp 22RHA1077.C1 Project Type OC C U P A N T L O A D A S S E S S M E N T 12 1 + 1 2 5 M C F A D D E N P L A C E NE W P O R T B E A C H , C A 9 2 6 6 3 Th e S t a g B a r + K i t c h e n MCFADDEN PLACE, LLC 3334 EAST COAST HIGHWAY, #418 CORONA DEL MAR, CA 92625 ATTN: MARIO MAROVIC 949-675-2340 BUSINESS 949-813-5683 MOBILE 1 Permit Submittal 03.23.23 2 PC RE Submital 05.15.23