HomeMy WebLinkAboutF2022-0164 - Miscoiv( POTTER BELLS The Symbol of Protection Features • Listed for indoor and outdoor use • Outdoor use requires BBK-1 or HC-BB weatherproof back box • Indoor use mounts directly to standard 4- box • Low current draw • High dB output • Available in 6", 8" and 10- sizes PBA-AC Description These vibrating type bells are designed for use as fire or general signaling devices. They have low power consumption and high decibel ratings, The unit mounts on a standard 4" (101mm) square electrical box for indoor use or on a model BBK-1 or EIC-BB weatherproof backbox for outdoor applications. Weatherproof backbox model BBK- 1 or HC-BB, Stock No, 1500001, Notes I. Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464, UL temperature range is -30' to 150°F (-34to 66°C) 2, Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. Size inch Imni) bltage Ishidel Number Stock Number ' Current (Max,)' Typical dB at ft 10 (3m112) Minimum dB t 10 afi r3m)(1) FN.) dB 6 (150) 24VAC PBA246 1806024* ,17A 91 78 - 8 (200) 24VAC PBA248 1808(124* J7A 94 77 - 10 (250) 24VAC PBA2410 1810024' ..17A 94 78 - 6 (150) 120VAC: PRA 1206 1806120* .05A 92 83 77 8 (210 I 20 VAC PBA 1208 1808120' .05A 99 64 78 1(I(250) 120VAC PHA 12010 1810120* .05A 99 86 82 Technical Specifications Dimensions 6"1150mraL 8"12.00mm1 and 10" (250inni) Enclosure Cover: Steel Finish: Red Powder Coal Base: o non -corrosive cmpom site aterial All pans have corrosion resistant finishes Model IiHK-1 or HC-BB weatheiprouf backbox.(optional) Environmental Limitations Indoor or outdoor use (Sec Non 1 -441' to 150`FC-4-0' to 66'C) (Ou(door use requires weatherproof backbox.) Optional Equipment (8" and 1(1" Only/ Bell Guard Bracket Pan Number 00,2,0141 Service Use NE( 13, 72, loyal AEU Termination AC Bells - 4 No. 18 A:NG stranded wires Voltages Available 214,:\07,,,A,,(v.' : *Specifications subject to change without notice. • Installation must he perfornied by qualified personnel and in accordance withal national and local codes and ordinances. • Shock hazard. Disconnect power source before servicing. Serious injury or death could TOSti I • Risk of explosion. Notfor use in hazardous locations. Serious injuiy or death could result. Nr4", AL,P In outdoor or wet installations, hell musi he mounted with weatherproof backbox. MK-1 or 11C-RB. Standard electrical. boxes will not provide n weatherproof enclosure. If the hell andfor assembly is exposed to moisture. it may fail or create an cleenical hazard. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 www.pottersignal.com 5401)776 - R EV AA • 1/21 PAGE 1 OF 2 POTTER The Symbol of Protection BELLS PBA-AC Installation The bell shall be installed in accordance with NFPA 13. 72, or local AH.1. The top of thc device shall be no less than 90" AFF and not less than 6" below the ceiling. 1. Reinove the gong. 2. Connect wiring (see Fig. 3). 3. Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). 4. Reinstall the gong (he sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). 5. Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). Bell Dimension Inches (mm) Fig I DWG, 776, Wiring Rear View Fig 3 A.C, BELLS FROM CONTROL PANEL OR PRECEDING BELL CAUTION; WHEN fl F TRICAL SUPERVISION 5 REQUIRED USE IN AND CUT LEADS AS spiovnt NOTES: 1. WHEN USING A.C. BELLS, TERMINATE EACH EXTRA WIRE SEPERATELY AFTER LAST BELL. 2. END -OF -LINE RESISTOR IS NOT REQUIRED ON AC BELLS . Weatherproof Backbox Dimensions Inches (mm) MODEL BBK-I OR HC-BB Fig 2 4- 46 14011) 0 4 I tliAnino Potter Electric Signal Company, LLC Si. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 5400776 - AA • 1121 PA4iE 2 OF 2 CALIFORNIA DEPARTMENT OFFORESTRY & FARE PROTECTION OFFICE OFTHE STATE FIRE MARSHAL FIRE ENGINEERING ' BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7135-0328:0118 CATEGORY: 7135—AUDIBLE DEVICES RATING: Page 1 of 1 Potter ElectAcSignal Co16O0Park 37OPlace, Hazelwood, N1UG3042United States Contact: Brad 6enongo|i(314)5H5'GSOOFax (314)5B5'88QB Emo||:bnado@potternignm|.nom Models 5QG24-153875.SB624'7S11D.PBA248.PBA248.PBA241D.PBA12OG.PBA1ZO8. PBA1201O.^PBD'12O.°PBD'128.°PBD'121O.^PBD'24J.°PBO'248.^PBD-2410 vibrating bells. Suitable for outdoor use when used with Model BBK-1 backbox. Models are AC or DC powered and available in 0^. 8^ond 10''. yWodo|o yNRA'S. -Mand -1D bells, suitable for outdoor use when used with Model BBX-1 backbox. Refer to listee's data sheet for detailed product description and operational considerations. PBA'248.'248.-2410: 24VAC PBA'1206.'1208.'12010: 128VAC yNBA'6.-8.'10: 12or24VDC ^PBD'126.'128.'1210: 12VDC. .12A ^PBO'246.-248.'2410:24VDC..06A INSTALLATION: In accordance with listee's printed installation instruc0on, applicable codes & ordinances, and in a manner acceptable to the authority having jurisdiction. K8M`RMJNG: Liate*e'aname, model number and ULlabel. APPROVAL: Listed as audible devices for use with separately listed compatible fire alan-n control units. If this appliance is required to produce a distinctive three -pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition, the appliance must be used with a fire alarm control unit that can generate the temporal pattern signal. Refer tomanufacturer's Installation Manual for details. This UnVnu in based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test mnuhu and/or other data but does not nmma an independent verification of any claims. This listing is not an endorsement o, recommendation of the item listed. This listing should not be used to verify cm,em, operational requirements or installation criteria. Refer to |iuoey'o data ohoot, installation instructions andlv, other Date Issued: Authorized By: July 01,2021 DAVID CAQTILlO,.M.E.FPE Fire Engineering Division Listing Expires June 30,2022 POTTER The Symbol of Protection PCVS Series Control Valve Supervisory Switch Features • NEMA 4X'` (IP 65) and 6P (IP 67) *Enclosure is 4X. For additional corrosion Protectiono mounting hardware, use model PCVS-2 CRI1 • -40" to 140" (-40°C to 60°C) operating temperature range • Visual Switch Indicators • Two conduit entrances • Adjustable length trip rod • Accomodates up to 12AWG wire • Switch detects tampering and valve closure • RoHS compliant • Two S PDT contacts NOTICE Before any work is done on the fire sprinkler or fire alarm system, the building owner or their authorized representative shall be notified. Before opening any closed valve, ensure that opening the valve will not cause any damage from water flow due to open or missing sprinklers, piping, etc. CE Important: This document contains important information on the installation and operation of PCVS valve supervisory switches. Please read all instnictions carefully before beginning installation. A copy of this document is required by NFPA 72 to be maintained on site. Description Technical Specifications The Model PCVS is a weather proof and tamper resistant switch for monitoring the open position of fire sprinkler control valves of the wall and yard post indicator and butterfly types. Two SPDT (Form (') contacts are provided which will operate when the valve position is altered from an open state. The unit mounts in a 1/2" NPT tapped hole in the post indicator or butterfly valve housing. The device is engaged by the indicating assembly of the post indicator or the operating mechanism of the butterfly valve, actuating switches when the valve is fully open. The unit should he installed where it is accessible for service. The cover is held in place by two tamper resistant screws that require a special -tool to remove. The tool is furnished with each device. Testing The operation of the PCVS and its associated protective monitoring system shall be tested upon completion ofthe installation and in- spected, Tested and maintained in accordance with all applicable local and national codes and standards and/or the Authority Having Juris- diction, (manufacturer recommends quarterly or more frequently). A minimum test shall consist of turning the valve operating mechanism towards the closed position. The PCVS shall operate within the first two revolutions of the operating mechanism. Fully close the valve and ensure the PCVS does not restore. Fully- open the valve and ensure that the PCVS restores to normal. Dimensions See Fig 10 Weight I A) lbs (0,45 kg) Enclosure Cover: Die Cast Finish: Red Powder Coat Base: Die Cast Finish: Black Powder Coat All parts have corrosion resistant finishes Cover Tamper Tamper Resistant Screws Optional Cover Tamper Switch Available Contact Ratings PCVS-2: Two Sets of SPDT (Form C) I 0.0 Amps at 125/250 VAC 2.0 Amps at 30VDC Resistive I 0 mAmps minimum at 24 VDC Environmental Limitations -40° F to 140"F (-40°C to 60°C) NEMA 4X (IP 65) and NEMA 6P Enclosure ([P67) (Use suitably rated conduit and connector) Indoor or Outdoor Use (Sec PIVSU-EX Bulletin 5400694 for Hazardous locations) Conduit Entrances Two Knockouts for 1/2" conduit provided (Sec Notice on Page 7 and Fig. II on Page 6) Service Use NFPA 13, 13D, I3R, 72 Specifications subject to change without notice Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-09 Customer Service: 866-572-3005 • www.pottersignal.com 5401526 - REV F • 8/15 PAGE i OF 7 POTTER The Symbol of Protection PCVS Series • Control Valve Supervisory Switch Theory Of Operation The PCVS is a spring loaded switch. It is in normal position when the trip rod is pulling against the spring force. Normal is when the switch is installed on the valve and the valve is fully open. As the valve closes, the valve actuator moves away from the trip rod of the PCVS and the spring on the PCVS pulls the trip rod over and trips the switch. Alternate Window Installation and Moving Hood Installation Target Moes Up as Valve is Shut Fig I Subject to the approval of the "authority having jurisdiction" the alternate method of installation shown in Fig. I may be used. En this method, one of the glass windows of the housing is replaced with a 1/4" thick metal plate that is cut to fit in place of the glass and drilled and tapped to recieve 1/2" NPT pipe nipple. In some cases it may be necessary to attach an angle bracket to the target assembly to engage the PCVS trip rod. Steel Tripping Block Replaces Open Marker Plate Replaces Glass Target Assembly Houd Moves Down as Valve is Shut Fig If the target is stationary and a hood arrangement is used, such as is shown in Fig. 2, the hood must he drilled with a 23132" drill and tapped with a 1/2" NPT. The center line of this hole should be 1/8" below the portion of target assembly that strikes the PCVS trip rod. The I I 3/8" dimension shown is for a Clow Valve. Flexible conduit must he used for this type of installation. (More on pg. 3). Potter Electric Signal Company, LLC • St. Louis. MO • Tech Support: 866-956-0988 Customer Service: 866-572-3 • www.pottersignal.com 5401526 - REV F • 8115 PAGE 2 OF 7 POTTER The Symbol of Protection PCVS Series Control Valve Supervisory Switch Typical Installations On Post Indicator Valve Housings Fig 3 fl Fig 4 ,et moves up s valve is shut. NOTE: Before any work is done on the fire sprinkler or lire alarm system, the building owner or their authorized representative shall be notified, Before opening any closed valve, ensure that opening the valve will not cause any damage from water flow due to open or missing sprinklers, piping, ete. /. Position the valve to fully open ('OPEN" should appear in the window of the housing). Partially close the valve while observing the direction that the target assembly moves. Reopen the valve. lf the valve housing is predrilled with a 1/2" NPT for installation of a monitoring switch, remove the 1/2" plug and fully open the valve. Make sure that 'OPEN" appears in the window of the housing. GO TO STEP NO, 6, 2. lithe valve is not pre -drilled for 112" NPT, remove the head and target assembly (consultation with valve manufacturer is recommended). 3. If the target assembly moved up as the valve was closed, measure the distance from the bottom of the head to the lower part of the target assembly that will contact the trip rod of the PCVS (see Fig. 3). This is usually a plate or bar on the target assembly, on a side adjacent to the "OPEN/SHUT" plates. Subtract 178" froni the measurement. If the target moved down as the valve was closed, measure the distance from the bottom of the head to the upper portion of the target assembly that will contact the trip rod of the PCVS (see Fig. 4). Add I/8" (3,2mn-i) to this measurement. 4. Mark the housing at the proper location. Using a 23/32'' (I8,2mm) drill bit drill and then tap a 1/2- NPT in the housing on the side that coincides with the portion of the target assembly that will engage the trip rod of the PCVS. 5. Replace the head and target assembly-. 6. Loosen the socket head screw that holds the nipple in the PCVS and remove the nipple. 7. Screw the Iocknut that is provided onto the nipple. 8. Screw the nipple into the 1/2" NPT hole in the valve housing hand tighten. Tighten the locknut against the valve housing to secure the nipple fumly in place. 9. Insert a scale or probe thru the nipple to measure the distance from the open end of the nipple to the target assembly. Subtract 1/2" (12.5mm) from this measurement. 'argct moves down salve is shut, NOTE: In some cases, it may be necessary to attach an angle bracket to the target assembly to engage the PCVS trip rod, la Using the special tool provided, loosen the two cover SUMS and remove the cover from the PCVS. 11. Loosen the locking screw that holds the trip rod in place and adjust the rod length, from the end of the collar to the end of the rod, using the dimension determined in Step 9. Tighten the locking screw to 5 in-lbs minimum to hold the rod in place and properly seal the enclosure. 12. Partially close the valve to move the target assembly away (3 to 4 revolutions of the handle/hand wheel). 13. With the PCVS positioned so the spring will pull the trip rod to follow the target as thc valve is closing, slide the PCVS over the nipple. Tighten the socket head screw in the collar. 14. Carefully open the valve to the hilly open position. As the target moves to the open position it should engage the trip rod and actuate the switch(es). There should be a minimum overtravel of 1/2 revolution of the handle/hand wheel after the switch( es) actuate (a continuity meter connected to each set of contacts is one method that could be used to determine this). 15. Slowly close the valve. The switch must operate during the first two revolutions of the handle/hand wheel or during 1/5 of the travel distance of the valve control apparatus from its norrnal condition, NOTE: Small adjustments of the target position may be necessary (consultation with valve manufacturer is recommended). 16. C'omplete the required electrical wiring, connections and tests. The valve should be operated through the entire cycle of fully closed and fully open to determine the integrity of the PCVS installation and the signaling system. Check that all electrical and mechanical connections are secure. / 7. Reinstall the cover and tighten the cover screws to 15 in-lbs minimum to properly seal the enclosure. 18. When the installation and testing are complete, return valve to its proper position, 19. Alternative installation for other post indicator valve housing shown in Fig. 1 and 2, Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-09 / Custorner Service: 866-572-3005 • wwwpottersignaLcom 5401576 -REV I, • 8/15 PAGE 3 OF 7 POTTER The Symbol of Protection PCVS Series Control Valve Supervisory Switch Typical Installation on a Butterfly Valve Fig 5 Typical Indicating Butterfly Valve Fig 6 Dresser Indicating Butterfly Valve Valve Partially Closed Valve Open 1. Remove the 1/2" NPT plug from the gear operator case. 2. Loosen the set screw that holds the nipple in the PCVS and remove the nipple. 3. Screw the locknut that is provided onto the nipple. 4. Screw the nipple into the 1/2"NPT hole in the gear operator -hand tighten. Tighten the locknut against the case, to secure the nipple firmly in place 5. Partially dose the valve to move the boss on the gear hub out of the way (3 or 4 revolutions of the hand wheel or crank). 6. Using the special tool provided, loosen the two cover screws and remove the cover from the PCVS. 7. °tient the PCVS so the spring will pull up the trip rod to follow the actuating cam inside the valve. NOTE: If trip rod length is excessive, loosen the lucking screw and remove the trip rod from the trip lever, Using pliers, break off the one (1) inch long notched section (sec Fig. (2). Reinstall the trip rod, tightening the screw to 5 in-lbs minimum, and repeat Step 7 procedure. 8. Remove device from nipple and shorten the trip rod 1732" (0,80mm) (this is to prevent the trip rod from dragging on the gear hub inside the valve). Tighten the locking screw to bold the rod in place. Re -install the device on the nipple. Tighten the screw in the collar against the nipple. NOTE: In some cases it may he necessary to remove the e) gear box cover to ensure correct operation (consultation with the valve manufacturer is recommended). 9. Carefully open the valve to its full opcn position, as the boss on the gear hub moves to the open position it must engage the PCVS trip rod and actuate the switch(es). There should be a minimum overtravel or revolution of the crank or hand wheel Mier the switch(es) actuate (a continuity meter connected to each set of contacts is one method that could be used to determine this). NOTE: Slight adjustment of gear stops may be necessary to prevent overtravel of the trip rod (consultation with valve manufacture is recommended). 10. Carefully close the valve. The swi h(es) must operate during the first two revolutions of the crank or hand wheel or during 1 /5 of the travel distance of the valve control apparatus from its normal condition. 11. Complete the required electrical wiring. connections and tests. The valve should be operated through the entire cycle of fully closed and fully open to detemtine the integrity of the PCVS installation and signaling system. 12. Reinstall the cover and tighten the screws to 15 in-lbs minimum to properly seal the enclosure. 13. When the installation and testing are complete, return valve to its proper position. Potter Electric Signal Company, LLC • St. Louis. MO • Tech Support: 866-956-I 9 Customer Sery : 66-572-3005 • www.puttersignal.com 5401526 - REV F. • 8115 PAGF 4 OF 7 POTTER The Symbol of Protection PCVS Series Control Valve Supervisory Switch Typical Pressure Reducer Type Valve Installation Fig 7 1/16" (1,6 mm) Minimum Gap This figure shows the Model PCVS mounted on the valve yoke, with a bracket supplied by the valve manufacturer, to supervise a pressure reducer type valve. NOTE: This application is subject to the approval of the authority having jurisdiction. PBK - Butterfly Valve Kit for Valves with Internal Supervisory Switches Fig 8 Locknuts Both Sides Bracket and Locknut Supplied With PBK Mounting Kit Pratt Butterfly Valve Kit as used to mount a PCVS on a Pratt Model IBV Valve. Kits contain: Bracket, nuts and instructions NOTE: Due to changes in valves, brackets may need to be modified by installer. This application is subject to thc approval of the authority having jurisdiction. PVK - Pratt PIVA Post Indicator Valve Kit Fig 9 Machine Screw #8-32 Pratt Valve Kit as used to mount a PCVS on a Pratt Model PIVA Valve, Kit contains; Instructions, template, screw and nut. NOTE: This application is subject to the approval of the authority having jurisdiction. Potter Electric Signal Company, LLC • St, Louis, MO • Tech Support: 866-956-0988 / Customer Service: 866-572-3005 • www.pottersignal.com 540[576 REV • 515 PAGE 5 OF 7 4 POTTER The Symbol of Protection PCVS Series Control Valve Supervisory Switch Breaking Excessive Rod Length Fig 12 Switch Terminal Connections Clamping Plate Terminal Fig 13 „.„4.14k2144.tjrtjoirttimitl„ An uninsulated sectionf a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire become dislodged trorn under the terminal. Failure to sever the wire may render thc device inoperable risking severe property damage and loss of life. Do not strip wire beyond 3/8" of length or expose an uninsulatcd conductor beyond the edge of the teminal block. When using stranded wire, capture all strands under the clamping plate. NOT CE All conduit and connectors selected for the installation of this product shall be suitable for the environment tor which it is to be used and shall be installed to the manufacturer's installation instructions. For NEN1A4, 4X, G. 6P installationsthe cover screws are recommended to he tightened to 15 in- Ibs minimum and the trip rod locking screw tightened to 5 in-lbs minimum to properly seal the enclosure. Typical Electrical Connections Fig 14 EOLR I-- COM NC NO NO NC COM Ii TO FIRE ALARM PANEL Ordering Information Niodel Description Stock No, PCVS-2 Porter Citiltrol Valve SwiL0 (doublc str ikch/ 1010203 PCVS-2 Clal Potter Control Valve Switch (double saaatehl. Corrosion aosistunt 316 stainless steel hardware 1010211 -- Covet Screw 5490424 _ tlex Key for Cover Sews and Installation Adjustments 5250062 PliK-S Pratt Butterfly Valve Kil - 3" 175mm) to 12- (30mm) 0090133 Pl3K-N1 Pratt Bunertly Valve Kil - 14-1355 min) .i.rici 16" (406 0090146 PHK-L Pratt Buncilly Valve Kit - 18' (457innit to 24- 16 Ill ninat 0090132 PVK Pratt Valve Kit I000060 _ Optiodat Covcj Tamper Switch Kil 0090200 KDK Kennedy Huth:ally Valve Kit 0090 1 43 II3K Tycho Butterfly Valve Kit 0090150 For oressu e reducer type valve installation kits (if required) contact valve manufacttuer. Engineering Specifications: Post Indicator & Butterfly Valves UL, CUL Listed / FM Approved and CE Marked valve supervisory switches shall be furnished and installed on all post Indicator and Butterfly valves that can be used to shut off the flow of water to any portion of the lire sprinkler system, where indicated on the drawings and plans and as required by applicable local and national codes and standards. The supervisory switch shall be NEMA 4X and 6P rated and capable of being mounted in any position indoors or out and be completely submerged without allowing water to enter the enclosure. The enclosure shall be held captive by tamper resistant screws. The device shall contain two conduit entrances and two Single Pole Double Throw (SPDT) switches. The device shall contain a removable I/2" NPT nipple and adjustable trip rod. the trip rod shall be held captive by a set screw accessible upon removal of the cover. The switch contacts shall be rated at 10A, 1251250VAC and 2A, 30VDC. Post Indicator and Butterfly Valve supervisory switch shall be model PCVS-2 manufactured by Potter Electric Signal Company LLC NOTICE Supervisory switches have a normal service life of 10-15 years. However, the service life may be significtuitly reduced by local environmental conditions. Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-0988 Customer Service: 866-572-3005 • www.pottersignal.com ISO 800120011 I DESIGNING, MANUFACTURING, CERTIFIED I & DISTRIBUTING QUALITY SYSTEMS 5401526 - REV F • 8'15 PAGE 7 OF:7 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7770-0328:0010 CATEGORY: 7770 -- VALVES/SWITCHES LISTEE: DESIGN: Page 1 of 1 Potter Electric Signal Co1609 Park 370 Place, Hazelwood, MO 63042 United States Contact: Brad Serangeli (314) 595-6900 Fax (314) 595-6999 Email: brads@pottersignal.com Supervisory switches listed below to monitor pressure, OS&Y, gate, globe/gate, PIV, tank temperature or water level valves. Refer to Iistee's data sheet for detailed product description and operational considerations. HLS-B WLS-W WLS-S PS-40A PS-120A OSYSU-2 OSYS-B PMS PTS-B OSYSU-1 GVS PCVS-1 PIVS-B TTS-S TTS-W PCVS-2 WLS PTS-C PS40 PS120 RBVS `PS15 *PS25 INSTALLATION: In accordance with Iistee's printed instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation and FM or UL label. APPROVAL: Listed as sprinkler system supervisory switches. NOTE: Formerly 7738-0328:010 'Revision 09-07-2016 do This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation Instructions and/or other Date Issued: Authorized By: July 01, 2021 DAVID CASTILLO„ M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2022 POTTER The Symbol of Protection PCVS Series Control Valve Supervisory Switch Dimensions Fig 10 4.00 [101.60 J 3.20 [81.26 ] 7.86 [19953 ] 9 2. 9 [70.87 ] .77 [19,61 ] 01,10 [27.92 ] Rod retracted and breakaway section removed .85 [21.51 ] EM 11 0.84 21.44 ] .12 [3.05 J 1.52 [38.61 ] Rod Fully Extended (2) o.886 Knockouts For 1/2" Electrical Conduit Connections Ground Screw Lock Nut 1/2"-14 NPT Nipple Trip Rod 2.72 [69 os ] Cover Tamper Switch (Optional) 3.05 [77.47 ] 2.25 [57.13 I 2,10 [53.34 ] wm swigu Knockout Removal Removed Fig 11 To remove knockouts: Place screwdriver at the center, Socket Head Screw edge of knoekouts, not in NOTE: Do not drill into the base as this creates metal shavings which can create electrical hazards and damage the device. Drilling voids the warranty. Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-0988 / Customer Service: 866-572-3005 • www.pottersignaLcom 5401526 REV I= • 8115 PA(;E OF 7 CALIFORNIA DEPARTMENT OFFORESTRY & FIRE PROTECTION OFFICE 0FTHE STATE FIRE MARSHAL FIRE ENGINEERING ^ BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7770'0328:0001 CATEGORY: 777O—VALVES/SWITCHES LISTEE; Page 1 of 1 Potter Electric Signal Co1H0QPark 37UPlace, Hazelwood, |NOG3042United States Contact: Brad Serunge|i(314)595'8QOOFax (314)595'G99S Email: brads@poffersignal.com DESIGN: Vane and pressure type water flow alarm switches listed below. Refer tobuh»e'sdata sheet for detailed product description and operational considerations. VaneTvPau: VSR'CF V8R'D VSR'F VSR'SF VSR-FE'2 VS'SP VS'F VSR'8FG VSR'3FT V8G VGR VSR-S VSR,C V8R-ST V8R'SG Pnaeoun*Tvpa: WFS-B VVF3R'C VVFSPD'8 p31U INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Lis1ee'sname, model number and ULcvFyNlabel. APPROVAL: Listed ouwaterflowalarm switches for use with fire sprinkler systems. Vane models may be used |nwet pipe systems; pressure models may baused inwet urdry systems. N1odo|V8R-CF iofor use unK.LorK1copper pipe (2".24CZ".3".4°)and listed CPVCpipe (2",2'1/2".3^). Model VSR-GFfor use on 1". 1'1/4^. 14/2^and °2"steel, copper orlisted plastic pipe. yNodo| VSGiafor low flow rate. Model VSR-SFG)and VSR-SFTare for use on 1" . 1'1/4" . 1'1/2"and °2^ plastic pipe. Models VS'F.VGR'F.VSR,FEand VSR-FE'2iofor use un2".2'1/%".3".3'1/2".4^. 5''. 8"' 8"end 10" pipe. *Model VSRiofor use on ntoa| pipe sizes from 2^thnnugh 8" Vane type switches may be used outdoors when the outdoor temperature never falls below 40oF. This listing is based upon technical data submitted by the applicant. CSpM Fire Engineering staff has reviewed the test results and/or other data but down not make an independent verification of any claims. This listing is not an endorsement or mcnnnnmnuaVon of the ioonn |iomu. This listing should not be used to verify ounwm operational requirements or installation udoerlo. Refer to omme'o data ehem, installation Instructions and/or other Date Issued: Authorized By: July 01,2021 DAVID CASTILLO,,M.E.F.PE Listing Expires June 30, 2022 POTTER The Symbol of Protection VSR VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD Fig. 2 To remove knockouts: Place screwdriver a inside edge ofknockouts. not in the center. NOTICE Do not drill into the base as this creates metal shavings which can create electrical hazards and damage the device. Drilling voids the warranty. Fig. 3 Break out thin section of cover when wiring both switches from one conduit trance, Fig. 4 Switch Terminal Connections Clamping Plate Terminal NG (MG. 1166-16 An uninsulated section nconductor shouLd not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire become dislodged from under the terminal, Failure to sever the wire may render the device inoperable risking severe property damage and loss of life. Do not strip wire beyond 3/8'' of length or expose an uninsulated conductor beyond the edge of the terminal block. When using stranded wire. capture all strands under the clamping plate. CONNECTOR Fig. 5 Typical Electrical Connections Notes: 1. The Model VSR has two switches, one can he used to operate a central station, proprietary or remote signaling unit, while the other contact is used to operate a local audible or visual annunciator. For supervised circuits, see "Switch Terminal Connections" drawing and warning note (Fig. 4). Testing The frequency of inspection and testing for the Model VSR and its associated protective monitoring system shall be in accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). If provided, the inspector's test valve shall always be used for test purposes. If there arc no provisions for testing the operation of the flow detection device on the system, application of the VSR is not recommended or advisable. A minimum flow of 10 GPM (38 LPM) is required to activate this device. NOTICE Advise the person responsible for testing of the fire protection system that this system must be tested in accordance s'ith the testing instructions. Fig. 6 Mounting Dimensions 89.0 rnm) 234 in (59.4 min 1.;4301:1 til;T 1.3-1{1/LT WASHER PIPE SADDLE PIPE: - PLASTIC PADDLE '-1.11lo ril'E DIA. 5,25 , 33.4 trmn) WA. 1141,14 NOMINAL PIPE DIA. I 75 01 o-44.5 klM) FOR DN 5,) ON 65 2 NOMINAL P550 DU_ *2.125 NMI) FOR DN. 05/2(11/3)0 Fig. 7 GREEN GROUND SCR)) VS OWO.D46-16 PRINTED IN USA NIFG. 45401146 - REV NI 1E15 PAGE 3 OF 4 POTTER The Symbol of Protection VSR VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD Specifications subject to c out notice. Ordering Information Nominal Pipe Size Model Part Number 11.1111111111EMIED IMESIMINEMIEMZEM MIIININIEZEI 1.111.1111M1.111 DN I 00 IIMIZEMI 1144425 VSR-3 I 44403 VSR-4 1144404 IMEMEI MILIMMEMEMI =NM VSR-5 IMEZIE 44406 DN200 VSR-6 MIMI 1144408 Optional: Cover Tamper Switch Kit, stock no. 0090148 Replaceable Components: RetardSwitch Assembly, stock no. 1029030 UL, CUL and CSFM Listed, FM Approved, LPCBApproved,For CE Marked (EN12259-5) / VdS Approved model use VSR-EU Service Pressure: 450 PSI (31 BAR) - UL Flow Sensitivity Range for Signal: 4-10 GPM (15-38 LPM) - UL Maximum Surge: 18 FPS (5.5 ni/s) Contact Ratings: Two sets of SPDT (Form C) 10.0 Amps at 125/250VAC 2,0Amps at 30VDC Resistive 10 mAmps min. at 24VDC Conduit Entrances: Two knockouts provided for 1/2" conduit. Individual switch compartments suitable for dissimilar voltages. Environmental Specifications: • NEMA 4'1P54 Rated Enclosure suitable for indoor or outdoor use with factory installed gasket and die -east housing when used with appropriate conduit fitting. • Temperature Range: 40°F - 120F, (4.5°C -49"C)- UL • Non -corrosive sleeve factory installed in saddle. Service Use: Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-13D Residential occupancy up to four stories NEPA-13R National Fire Alarm Code NFPA-72 "-ilj:!!r11!77!11:11:E1Mnjiltiliiopoo • Installation must be performed by qualified personnel and in accordance with all national and local codes and ordinances. • Shock hazard. Disconnect power source before servicing. Serious injury or death could result. • Risk of explosion. Not for use in hazardous locations. Serious injury or death could result. CAUTION Waterflow switches that are monitoring wet pipe sprinkler systems shall not he used as the sole initiating device to discharge AFFF, deluge,. or chemical suppression systems. Waterflow switches used for this application may result in unintended discharges caused by surges, trapped air, or short retard times. Important: This document contains important information on the installation and operation of the VSR watertlow switches. Please read all instructions carefully before beginning installation. A copy of this document is required by NFPA 72 to be maintained on site. General Information The Model VSR is a vane type waterflow switch for use on wet sprinkler systems. It is UL Listed for use on a steel pipe; schedules 5 through 40, sizes 2" - 6" and is UL Listed and FM Approved for use on steel pipe; schedules 10 through 40, sizes 2" thru 8" (50 mw thru 200 mw), LPC approved sizes are 2" thru 8" (50 inm that 200 min). See Ordering Information chart. The VSR may also be used as a sectional waterflow detector on large systems. The VSR contains two single pole, double throw, snap action switches and an adjustable, instantly recycling pneumatic retard. The switches are actuated when a flow of 10 GPM (38 LPM) or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period. Enclosure The VSR switches and retard device are enclosed in a general purpose, die-cust housing. The cover is held in place with two tamper resistant screws which require a special key for removal. A field installable cover tamper switch is available as an option which may be used to indicate unauthorized removal of the cover. See bulletin number 5401103 for installation instructions of this switch. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 866-956-1211/Canada 888-882-1833 • www.pottersignal.com PRINTED IN USA MFG, 454(11146 - REV NI PAGE 1 OF 4 11/15 POTTER The Symbol of Protection VSR VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD Maintenance Inspect detectors monthly. If leaks are found, replace the detector. The VSR waterflow switch should provide years of trouble -free service. The retard and switch assembly are easily field replaceable. In the unlikely event that either component does not perform properly, please order replacement retard switch assembly stock 41029030 (see Fig. 8). There is no maintenance required, only periodic testing and inspection. Retard/Switch Assembly Replacement(See Fig. 8) NOTICE The Retard/Switch Assembly is field -replaceable without draining the system or removing the waterflow switch from the PiPe I . Make sure the fire alarm zone or circuit connected to the waterflow switch is bypassed or otherwise taken out of service. 2. Disconnect the power source for local bell (if applicable). 3. Identify and remove all wires from the waterflow switch. 4. Remove the (2) mounting screws holding retard.'switch assembly to the base. Do not remove the (2) retard housing screws. 5. Remove the retard assembly by lifting it straight up over the tripstem. 6. Install the new retard assembly. Make sure the locating pins on the retard/switch assembly fit into the locating pin bosses on the base, 7. Re -install the (2) original mounting screws. 8. Reconnect all wires. Perform a flow test and place the system hack in service. Fig. 8 DO NOT REMOVE (121 RETARD HOUSING SCREWS REMOV2j oRIGINAL mouNTING SCREWS HOLDING RETARDISWITCH ASSEMBLY TO BASE BREAK OUT THIN SECTIONOF COVER WHEN WIRING BOTH SWITCHES FROM ONE CONDUIT ENTRANCE. (2) ORIGINAL MOUNTING :CREWS RETARDISWITCH ASSEMBLY 124 LOCATING PINS (24 LOCATING PIN BOSSES IN BASE BASE DWG4 1146-10 Removal of Waterflow Switch • To prevent accidental water damage. all control valves should be shut tight and the system completely drained before waterflow detectors arc removed or replaced. • Turn off electrical power to the detector, then disconnect wiring. • Loosen nuts and remove U-bolts. • Gently lift the saddle far enough to get your lingers under it. With your fingers. roll the vane so it will fit through the hole while continuing to lift the waterflow detector saddle. • Lift detector clear of pipe. PRINTED IN USA MEG. 45401146 - REV NI PAGE 4 OF 4 11/15 POTTER The Symbol of Protection VSR VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD Installation (see Fig. 1) These devices may be mounted on horizontal or vertical pipe. On horizontal pipe they shall be installed on the top side of the pipe where they will be accessible. The device should not be installed within 6" (15 cm) of a fitting which changes the direction of the waterflow or within 24" (60 cm) of a valve or drain. NOTE: Do not leave cover off for an extended period of time. DraM the system and drill a hole in the pipe using a hole saw in a slow speed drill (see Fig. 1). Clean the inside pipe of all growth or other material for a distance equal to the pipe diameter on either side of the hole. Roll the vane so that it may he inserted into the hole; do not bend or crease it. insert the vane so that the arrow on the saddle points in the direction of the watcrflow. Take care not to damage the non -corrosive bushing in the saddle, The bushing should fit inside the hole in the pipe, Install the saddle strap and tighten nuts alternately to required torque (see the chart in Fig, 11. The vane must not rub the inside of the pipe or bind in any way. A CAUTION Do not trim the paddle. Failure to follow these insnuetions may prevent the device from operating and will void the warranty. Do not obstruct or otherwise prevent the trip stem of the flow switch from moving when water flows as this could damage the flow switch and prevent an alarm. If au alarm is not desired, a qualified technician should disable the alarm system, Fig. 1 DIRECT' N OF WATERFLOW 1)0 NOT LEArt: COUT,R OFF FOR ENTENDED PERIOD OF TIME rictrIEN NUTS ALFERNATELY MOUNT ON PIPE SO ARROW ON SADDLE -------POKrs IN DIRECTION OF WATERFLOW Retard Adjustment The delay can be adjusted by rotating the retard adjustment knob from 0 to the max setting (60-90 seconds). The time delay should be set at the minimum required to prevent false alaims CAUTION Hole must be drilled perpendicular to the pipe and vertically centered. Refer to the Compatible Pipe/Installation Requirements chart for size. Correct Incorrect ROLL PADDLE IN OPPOSITE DIRECTION OF WATERFLOW (Flowing water activates device in one direciion only.) DWG 1146-11 DN50 ONLY USE (2) 5180162 ADAPTERS AS SHOWN ABOVE lur.g.- Compatible Pipe/ Installation Requirements Model Nominal Pipe Size Nominal Pipe O.D. Pipe Wall Thickness Hole Size U-Dolt Nuts Torque Lightwall Schedule 10 (LILL Schedule 40 (10,1 I3S-138. 7 (l,,PC) DN (YDS) ' inch mm inch inm inch inn inch ' min inch min inch inin inch inm inch inm 11-1h Li-m VSR-2 2 DN50 2.375 60.3 .065 1.651 0.109 2.77 0.154 3.91 0.142 3.6 0,091 2.3 1.25 -' .125/- .062 33.0 .3i 2.0 20 27 VSR-2 1'2 2.5. - 2.875 73.0 .084 2.134 0. l20 3.05 0.203 5.16 _ - - VSR-2 112 - 0N65 3.000 76,1 - - - .. - - 0.142 , 3,6 0.102 2.6 5'SR-3 3 DN80 3.500 88.9 ' .083 2.108 0.120 3.05 t4.216 5.49 0.157 4.0 0.1 ! 4 2.9 2.00 ± .125 50.8 -± 2,0 VSR-3 112 3.5 - 4.000 101.6 - - 0.120 3.05 0.226 5.74 - - - VSR-4 4 DN100 4.500 114.3 .084 2.134 0.120 3.05 0.237 6.02 0.177 4.5 0. 6 3.2 VSR-5 5 - 5.563 141,3 - - 0.134 3.40 0.258 6.55 - - - VSR-6 6 DNI 50 6.625 168.3 .115 2.921 0.134 3.40 0.280 7.11 0.197 5.0 0.157 4.0 VSR-8 8 024200 8.625 219.1 - - 0.148 3.76 0.322 8.18 0.248 6.3 0.177 4.5 NOTE: For copper or plastic pipe use Model VSR-CF. PRINTED IN USA NIEG. 45401146 - REV NI 11'15 PAGE 2 OF 4