HomeMy WebLinkAboutF2022-0503 - MiscF-7t22- st)..74.3 It H---beta Fire Alarm System Record of Completion Name of protected property: HOAG MEMORIAL HOSPITAL PRESBERTERIAN Address: ONE HOAG DRIVE NEWPORT BEACH, CA. 92663 Representative of protected property (name/phone): ERIC LIDECIS Authority having jurisdiction: NEWPORT BEACH FIRE DEPARTMENT FIRE PREVENTION DIVISION Address/telephone number: OSHPD # : 11 HOAG LEADERSHIP CENTER 4. Type(s) of System or Service NFPA 72, Chapter 3 - Local tf alarm is transmitted to tocation(s) off premises, list where received: NFPA 72, Chapter 3 - Emergency Voice/Alarm Service Quantity of voice/alarm channels: na Single: Multiple: Quantity of speakers installed: na Quantity of speaker zones: Quantity of telephones or telephone jacks included in system: 0 NFPA 72, Chapter 5 - Auxiliary Indicate type of connection: N/A Local energy N/A Shunt N/A Parallel telephone Location of telephone number for receipt of signals: N/A NFPA 72, Chapter 5 - Remote Station Alarm: Via Telephone Supervisory: Via Telephone NFPA 72, Chapter 5 - Proprietary If alarms are retransmitted to public fire service communications centers or others, indicate location and telephone numbers of the organization receiving alarm: Indicate how alarm is retransmitted: Via Telephone X NFPA 72, Chapter 5 - Central Station Prime contractor: TRL SYSTEMS INC. Central station location: 400 East Ricon Rd. Ste. 300 CORONA Ca. 92789 Means of transmission of signals from the protected premises to the central station: McCulloh Multiplex x Digital alarm communicator Two-way radio Means of transmission of alarms to the public fire service communications center. (a) Via Telephone One-way radio Others (b) Via Telephone System Location: Organization name/phone Installer TRL SYSTEMS Supplier TRL SYSTEMS Service organization TRL SYSTEMS Location of record (as -built) drawings: Location of owners manuals: Location of test reports: 909-390-8392 909390-8392 909-3904392 Engineering Office Representative name/phone Wayne Morris / 909-208-4424 Wayne Morris / 909-208-4424 Wayne Morris / 909-208-4424 Engineering Office IOR A contract, dated , for test and inspection in accordance with NFPA standard(s) No(s). , dated ,is in effect. 2. Record of System Installation (Fill out after installation is complete and wiring checked for opens, shorts, ground faults, and improper branching, but prior to conducting operational acceptance tests.) This system has been installed in accordance with the NFPA standards as shown below, was inspected by Alex Cauiola on 3/27/2023 , includes the devices shown below, and has been in service since 3/27/2023 X NFPA 72, Chapters 1 2 3 4 5 6 7 (clmla all that apply) NFPA 70, National Electrical Code , Article 760 Manufacturer's instructions .fY Signed: Date: 3/27/2023 Organization: 3&L Systems 3. Record of System Operation All operational features and functions of this system were tested by Alex Cauiola on 3/27/2023 and found to be operating properly in accordance with the requirements of: X NFPA 72, Chapters IsiFPA 70, National Electri Manufacturer's instructiQ Other Signed: Organization: TRL Systems 1 2 3 4 5 6 7 (circle all that apply) 1 Code , Articie 760 4. Alarm - initiating Devices and Circuits Quantity and class of initiating device circuits (see NFPA 72, Table 3-5) Quantity: Style: Z Class: MANUAL 1 (a) 0 Manual stations Nocoded, activating Transmitters 0 Coded (b) 0 Combination manual fire alarm and guard's tour coded stations AUTOMATIC Coverage: Complete: Partial: (a) 1 Smoke detectors Ion 1 Photo (b) 0 Duct detectors on Photo (c) 0 Heat detectors FT FT/RR (d) 0 Sprinkler waterflow switches: Transmitters Noncoded, activating Coded (e) N/A Other (list): 5. Supervisory Signal -initiating Devices and Circuits (use Wanks to indicate quantity of devices) GUARD'S TOUR (a) N/A Coded stations (b) N/A Noncoded statens, activating transmitters (c) N/A Compulsory guard tour system comprised of stations and intermediate stations Note: Combination devices are recorded under 4(b) and 5(a) SPRINKLER SYSTEM (a) N/A Coded valve supervisory signaling attachments Valve supervisory switches, activating transmitters (b) N/A Building temperature points (c) N/A Site water temperature points (d) N/A Site water supply level points Electric fire pump: (e) N/A Fire pump power (f) N/A Fire pump running (g) N/A Phase reversal Engine -driven fire pump: (h) N/A Selector in auto position (I) N/A Engine or control panel trouble (j) N/A Fire pump running Engine -driven generator: (k) N/A Selector in auto position (I) N/A Control panel trouble (m) N/A Transfer switches (n) N/A Engine running Other supervisory function(s) (specify): transmitter 6. Alarm Notification Appliances and Circuits Quantity and class (see NFPA 72, Table 3-7) of notification appliance circuits connected to the system: Types and quantities of notification appliances installed: Quantity: 1 Style: Z Class: B (a) 0 Bells Inch (b) 0 Speakers (c) 1 Homs (d) 0 Chimes (e) 0 Other: (f) 1 Visual signals Type: 1 with audible 0 w/o audible 0 relocated (g) N/A Local annunciator 7. naling Line Circuits Quantity and class (see NFPA 72, Table 3-6) of signaling line circuits connected to system: Quantity: Existing Style: Z Class: B 8. System Power Supplies (a) Primary (main): Existing Nominal vottage: 24 VDC Current Rating: 8 amps Overcurrent protection: Type: Location: Slow Blow - Fold Back Current Rating: 8.0 amps (b) Secondary (standby): X Storage battery: Amp -hour rating: 24 Calculated capacity to drive system, in hours X 24 so Engine -driven generator dedicated to fire alarm system: Location of fuel storage: (c) Emergency or standby system used as backup to primary power supply, instead of using a secondary power supply: Emergency system described in NFPA 72, Article 700 Legally required standby system described in NFPA 70, Article 701 Optional standby system described in NFPA 70, Article 702, which also meets the performance requirements of Article 700 or 701 9. System Software (a) Operating system software revision level(s): (b) Application software revision levei(s): 5.12 (c) Revision completed by: 10. Comments EST 3 ALEX CAUIOLA TRL SYSTEMS INC. (name) (firm) Fe; r (signed) for central station or germ service company or installation contractor/suppler (tide) Frequency of routine tests and inspections, if other than in accordance with the referenced NFPA standard(s): 32743 (ate) System deviations for the referenced NFPA standard(s) are: N/A (signed) for central station or alarm service company or Instigation contractor/supplier (title) Upon completion of the systern(s) satisfactory test(s) witnessed (if required by the seiThor*y having jurisdIction): (date) (signed) representative of the authority having jurtscktion (title) (date)