Loading...
HomeMy WebLinkAboutS2022-0162 - MiscAu( CITY OF NEWPORT BEACH COMMUNITY DEVELOPMENT DEPARTMENT .e.. BUILDING DIVISION ' 100 Civic Center Drive) P.O. Box 17681 Newport Beach, CA 92658 www.newportbeachca.gov 1 (949) 644-3200 SPECIAL INSPECTION REPORT Project Address: 3601 Seabreeze Corona Del Mar Permit Number: Inspection Type (s): Shotcrete placement Inspection Date (s): 11/11/2022 ( ) Periodic (xj Continuous To the best of my knowledge, the work inspected was in accordance with the Building Division approved design drawings, specifications and applicable workmanship provisions of the U.B.C. except as noted above. Special Inspector signature: Date: 11 /11 /2022 Print Full Name: Newport Beach Registration No.: Raymond Mitchell NB-0715 SpeciallnspeaionReport 8-24-15 Py irbm d Te lq A-�ofCOPaebgBs/ac ASTM C39 - Compressive Strength of Cylindrical Specimens Client Name: ARCHULETA INSPECTIONS Project Name: NR Inspector's Name: Raymond F. Mitchell Project Address: 3601 Seabreeze lane Inspector's License No.: 83433448 Corona Del Mar, Ca Field Identification: NR Permit Number: NR Cast Data )Provided by Client) Material Description: SHOTCRETE 14" x 8" Cylinder Set Number: NR Cast Date: 11/11/22 Number of Samples: 3 Cast By: Raymond F. Mitchell Total Yards: 10 Contractor: NR Cement Type: II / V Material Supplier: Associated Ready Mix Cast Time: 9:37am Plant: #56 Mix Time: 90 min. Mix Design Number: 48011 Admixture: NR Ticket Number: 5606373 Slump - In.: NR Specified PSI: 4,500 Air Temperature: 76a F Design PSI: 4,500 Concrete Temperature: 75' F Location of Pour: Pool / Spa Notes: NR = Not Reported Laboratory Compressive Strength Data Date Specimen Received: 11/16/22 Date of Test: 12/9/22 Technician: On File Equipment Used: FORNEY F-25EX-F-CPI1-OT Calibration Date: 8/30/22 Specimen lD Age of Test(Days) Date of Test Time of Ten Specimen Dimensions Cross Sectional Area - In. Maximum Load -Lbs. PcPSI Facture Type 1-In. 2-In. 3-In. 4-In. PT- 64099.1 .1 7 11/18/22 11:23 AM 4.00 4.01 N/A N/A 12.60 50,760 4,030 2 PT- 64099.1 .2 28 12/9/22 9:15 AM 4.01 4.01 N/A N/A 12.63 65,180 5,160 4 PT - 64099.1 . 3 28 12/9/22 9:18 AM 4.01 4.01 N/A N/A 12.63 63,730 5,050 2 Average Pc = 5,105 Compliance with Specified Strength: THE TWO -SAMPLE AVERAGE 28-MY COMPRESSIVE STRENGTH EXCEEDS THE SPECIFIEDVALUE Technician Comments: a a weagmeoem e =xe4�a: rUnahu"cerpaa.e Wn�3:inameType OeagnatMPenSlM t39fYue 3: a1<"nqY-cnneaneeaR,l=c"Wmiur9=oag"�Ls=sarfnMre, F-saesnaue Pont xare a. ww¢ nnM refire m rnrM s petlmms. AWhonzed 5lgnature a1455EcumwAY,SANrAFESPNINGs CAM70 IOFFICEd30.28 55 IFAX43 26L5987 WFa WWW.PYIIAHIDTESnNG.COM I E P WDTESTNIG®GNAILCOM 23/117 CHRISTOPHER JEAN & ASSOCIATES, INC. ACOUSTICAL CONSULTING SERVICES June 7, 2023 Business License: #BT30044674 MR. BRETT MARDESICH LANDCRAFTERS, INC. 30100 Town Center Drive, Suite 0-251 Laguna Niguel, California 92677 SUBJECT: RESULTS OF ACOUSTICAL CERTIFICATION MEASUREMENT FOR 3601 SEABREEZE LANE -- CITY OF NEWPORT BEACH Dear Mr. Mardesich: We are pleased to inform you that the pool equipment installation located at 3601 Seabreeze Lane in the City of Newport Beach complies with the City's 55 dBA noise limit. No additional noise mitigation is necessary. The installation was measured on Wednesday, June 7, 2023, using a Larson Davis Model 700 Type 2 Sound Level Meter. The installation was observed to consist two Pentair Intelliflo pumps and a MasterTemp 400 heater, all located in a side yard setback. The measurement microphone was placed just beyond the top of the nearest property line wall/wood fence directly opposite the equipment. The measurement reported an equipment noise level of 52 dBA for both pumps and the heater unit operating simultaneously. This level complies with the City's 55 dBA noise limit. Thank you, and if there are any questions, please do not hesitate to call. Prepared by: 4140WE Jean,--- ,BOX 2325 - FULLERTON, CALIFORNIA - 92837 PHONE: 714-805-0115 1