Loading...
HomeMy WebLinkAboutPA2022-0315_20230214_Incomplete Ltr 2-13-2023\\cnb.lcl\data\Users\PLN\Shared\PA's\PAs - 2022\PA2022-0315\PA2022-0315 Incomplete Ltr.docx Tmplt. 02/09/11 COMMUNITY DEVELOPMENT DEPARTMENT PLANNING DIVISION 100 Civic Center Drive, P.O. Box 1768, Newport Beach, CA 92658-8915 949-644-3200 Fax: 949-644-3229 www.newportbeachca.gov NOTICE OF INCOMPLETE FILING February 13, 2023 Gregg Ramirez 11 Golden Eagle Court Aliso Viejo, CA gbrplanning@outlook.com Application No. Coastal Development Permit Staff Approval Modification Permit (PA2022-0315) Address 2741 Ocean Boulevard Thank you for submitting a coastal development permit, staff approval, and retaining wall modification permit for a substantial improvement and addition at 2741 Ocean Boulevard. The project currently includes the following requests and parameters: • Alteration. In accordance with Section 21.38.040(A) (Nonconforming Structures, Maintenance and Repairs), the replacement of fifty (50) percent or more of a structure is not repair and maintenance but instead constitutes a replacement structure. The current plans reflect replacement of 31% demolition in accordance with the agreed upon historical floor plans for the property. • Addition. In accordance with Section 21.52.035(c)(1)(d)(i) (Projects Exempt from Coastal Development Permit Requirements), a coastal development permit is required for an increase of ten (10) percent or more of the floor area of an existing structure where an improvement to the structure has previously been undertaken. • Addition. In accordance with Section 20.38.040(G) (Nonconforming Structures, Additions), additions shall be limited to (50) percent of the gross floor area of the existing structure within any ten (10) year period. The current plans reflect an addition of 43% to the existing floor area. • Addition. In accordance with Section 21.38.040 (G)(2) (Nonconforming Structures, Additions), the expansion shall be limited to a maximum of fifty (50) percent of the gross floor area of the existing structure. • Staff Approval. In accordance with Section 20.54.070 (Changes to an Approved Project), minor changes to a previously approved project (i.e. Variance No. VA1137) may be approved if certain findings can be made. Please make the additional request for this application, provide supporting \\cnb.lcl\data\Users\PLN\Shared\PA's\PAs - 2022\PA2022-0315\PA2022-0315 Incomplete Ltr.docx Page 2 description/justification of findings, and pay the application fee (invoice has been made in the CiViC portal). • Modification Permit. In accordance with Section 20.52.050 (Modification Permits) of the Zoning Code, an increase in the allowed height of retaining walls is requested to provide for pedestrian entry access in the 10-ft front setback from Ocean Boulevard to the front entrance of the home. In accordance with Section 21.38.040 (G) (Nonconforming Structures, Additions), the addition shall only be permitted if the nonconforming structure: a. “Does not block or impede public access to and along the sea or shoreline and to coastal parks, trails, or coastal bluffs; b. Does not block or impair public views to and along the sea or shoreline or to coastal bluffs and other scenic coastal areas; c. Conforms to coastal resource protection development regulations of Section 21.28.040 (Bluff (B) Overlay District), Section 21.28.050 (Canyon (C) Overlay District), Section 21.30.030 (Natural Landform and Shoreline Protection), Chapter 21.30A (Public Access and Recreation), or Chapter 21.30B (Habitat Protection); d. Is not located within an area identified as hazardous due to erosional factors or coastal hazards;” There are several aspects of the proposed addition that may conflict with the parameters identified above, including but not limited to: • The proposed retaining wall/planter design adjacent to Way Lane (triangular portion of the property) currently consists of unmodified bluff adjacent to the City’s Lookout Point. We highly recommend removing the proposed improvements in this area to maintain the natural bluff development. • The proposed chimney, which exceeds the maximum curb height limitation along Ocean Boulevard. • Consider minimizing the design of the entry stairs, guardrail, and retaining walls at the front entry to the minimum necessary for Building Code compliance to gain access to the home. • Consider reducing the amount of cut proposed into the bluff for the pool equipment area and hallway to gain access through the garage to the proposed elevator shaft. Adjustment of the above referenced items may help to offset this request. Please be advised that after reviewing the subject application, your submittal has been deemed incomplete and further information is required before we are able to proceed with the application process. The following documentation is required to complete the application: 1. Managing Member Agreement. Please provide a managing member agreement or other document that demonstrates who is the managing member to sign on behalf of Blues 1905, LLC. 2. Title Report. Please provide a copy of the title report prepared within six months to verify ownership. \\cnb.lcl\data\Users\PLN\Shared\PA's\PAs - 2022\PA2022-0315\PA2022-0315 Incomplete Ltr.docx Page 3 3. Project Plans. Refer to attached correction sheet with Planning Division comments for the plan set. a. Incorporate the site walls in grading plan or remove this work from the scope in the architectural set for consistency. The suggested approach would be to remove these features along Way Lane to preserve the integrity of the existing bluff and natural landscape in this area. 4. Visual Simulations. Provide a visual simulation from Ocean Boulevard out toward the harbor and down Ocean Boulevard toward lookout point to demonstrate the proposed view changes with the project. 5. Renderings. Provide a rendering of visual representation that overlays the envelope of the existing development with that of the proposed remodel/addition to show how the building envelope is changing along the Way Lane frontage. 6. Department Comments. Please refer to the attached comments from Building, Fire/Life Safety, and Public Works. Please address the comments with your next submittal. 7. Geotechnical Report. As this property is located within a coastal hazards area subject to landslides, please provide a copy of the preliminary geotechnical report for this project. Upon verification of completion, the application will be processed and scheduled for a Zoning Administrator Hearing. Should you have any questions regarding submittal requirements, please contact the project planner assigned here forth, David Lee, Senior Planner at 949-644-3225. By: Attachments: Planning Division Plan Check Corrections Water-Efficient Landscape Checklist for Submittal Building Division Comments Fire/Life-Safety Comments Public Works Department Comments Grade Plane Exhibit \\cnb.lcl\data\Users\PLN\Shared\PA's\PAs - 2022\PA2022-0315\PA2022-0315 Incomplete Ltr.docx Page 4 c: Sara Pijuan KAA Design Group Spijuan@kaadesigngroup.com Timothy Reynolds KAA Design Group treynolds@kaadesigngroup.com David Lee, Associate Planner dlee@newportbeachca.gov Residential Zoning Corrections Community Development Department Planning Division 100 Civic Center Drive; P.O. Box 1768 Newport Beach, CA 92658 949-644-3200 www.newportbeachca.gov Plan Check No.: PC2022- 3232 Address: 2741 Ocean Blvd Date: 02/13/2023 Corrections Required Contact Information “1” (First Review): 02/13/23 “2” (Second Review): “3” (Third Review): If you have questions regarding your plan check, please contact: Plan Checker: Makana Nova Email/Phone: mnova@newportbeachca.gov - 949-644-3249 Please contact me to discuss corrections prior to resubmitting. GENERAL INFORMATION 1. Zone: R-1 Setback Map No: S-10B PC Text: 2. Proposal: New Addition Alteration Other 50% ADD/ALT 3. No. of Units Allowed: 1 No. of Units Proposed: 1 4. Demo Proposed Yes No If Yes, number of units to be demolished COASTAL COMMISSION REVIEW 5. Coastal Zone: Yes Exclusion Zone No 6. Exempt because: 7. Categorical Exclusion No.: Effective Date: 8. Waiver No: Effective Date: 9. AIC No: Coastal Development Permit No: PA2022-0315 Effective Date: 10. 1 Coastal Approval Letter (all pages) to be scanned into plans. 11. 1 Comments: >10% ADDITION, DOES NOT QUALIFY FOR CEO DUE TO SUBSTANTIAL CONFORMANCE WITH EXISTING VARIANCE AND SIZE OF ADD, PENDING EFFECTIVE DATE OF CDP DISCRETIONARY ACTION 12. 1 Application required: Reason: 13. 1 Previous Discretionary Approvals: 1. Application Type VARIANCE No. For: SITE WALLS AND IMPROVEMENTS IN THE 10-FT FRONT SETBACK OVER 42 INCHES IN HEIGHT. 2. Application Type COASTAL DEVELOPMENT PERMIT No. For: ADD/ALT THAT DO NOT QUALIFY FOR CEO 3. Application Type No. For: 4. Application Type No. For: 5. Application Type No. For: 14. Please make an appt with: Phone: Email: 15. 1 Scan approval letter / resolution (including conditions) into plan sets. Copy attached 16. HOLD ON FINAL. The following items must be completed before the building permits are finaled: Residential Zoning Corrections (Cont’d) Updated: 01/20/2021 \\cnb.lcl\data\Users\PLN\Shared\PA's\PAs - 2022\PA2022-0315\PLNG PC2022-3232 CO MKN.docx (pw_CDD) Page 2 of 11 17. 1 Comments: Consider modifying the project design to 1) remove the wall/planter areas adjacent to Way Lane, 2) remove the new chimney that projects above the top of curb elevation, and 3) reduce the entry wall/stair to the minimim size and height necessary to comply with the Building Code. Residential Zoning Corrections (Cont’d) Updated: 01/20/2021 \\cnb.lcl\data\Users\PLN\Shared\PA's\PAs - 2022\PA2022-0315\PLNG PC2022-3232 CO MKN.docx (pw_CDD) Page 3 of 11 REQUIRED FEES 18. Fairshare Fee Contribution: 19. San Joaquin Hills Transportation Corridor Fee: 20. Other: LOT OR PARCEL STATUS 21. Legal Description: Lot: PCL B Block: 033 Section: Tract: CDM, RECORD OF SURVEY 2015-1098 22. Easement(s) on-site: Yes No Verify with Public Works 23. No person shall develop any structure including, but not limited to, a principal or accessory structure across a lot line per Section 19.04.035 (Development Across Property Lines) of the Subdivision Code. Please apply for a Parcel Map, Lot Merger, Lot Line Adjustment, or Certificate of Compliance to address underlying legal lot lines. 24. 1 Comments: DIMENSION ALL PROPERTY LINES ON THE SITE PLAN, SHEET A201. REFER TO INKED REMARKS ON THE PLAN CHECK SET. SETBACKS 25. Setback Regulations (20.30.110) *Setbacks are measured from property line to finished surface, unless otherwise specified. Front: 10' Left Side: 4' Right Side: 4' Rear: 10' Other: 26. Third Floor Step-backs (20.48.180A.2.c.) (Applicable to single- and two-unit dwellings in the R-1, R-2, R-BI, and RM zoning districts ) Front: Left Side: Right Side: Rear: N/A: N/A NO THIRD FLOOR FROM MAIN ACCESS OFF OF OCEAN BLVD. • Enclosed floor area and covered decks located on the third floor shall be stepped back a minimum of 15 feet from the front and rear setback lines. • For lots 30 feet in width or greater, a minimum step back of 2 feet from each side setback line shall also be required, including bay windows. 27. On residential lots wider than thirty (30) feet, if the primary entrance to a dwelling faces a side setback area the entry door shall be set back a minimum of five feet from the side property line and a three-foot-wide unobstructed walkway shall be provided up to a minimum height of eight feet between the primary entrance and the public street or alley. 28. 1 A minimum thirty-six (36) inch wide passageway shall be maintained within at least one side setback area adjacent to the principal structure. The passageway shall be free of any encroachments or obstructions from ground level to a height of eight feet, including mechanical equipment, and other items attached to, or detached from, the principal structure. 29. Comments: FLOOR AREA/SITE AREA LIMITATIONS 30. Lot Size: 10,912 square feet Lot Dimensions: See attached subdivision map with dimensions 31. 1 Buildable Area: lot area minus required setback areas = 10,219 SF PER PRIOR VARIANCE PLANS. PROVIDE A BUILDABLE AREA CALCULATION ON THE COVER SHEET OF THE PLANS. PROVIDE A SUPPORTING EXHIBIT IF NECESSARY TO DEMONSTRATE THE LOT AREA LESS THE SETBACKS FOR THIS UNUSUALLY SHAPED LOT. Residential Zoning Corrections (Cont’d) Updated: 01/20/2021 \\cnb.lcl\data\Users\PLN\Shared\PA's\PAs - 2022\PA2022-0315\PLNG PC2022-3232 CO MKN.docx (pw_CDD) Page 4 of 11 32. Floor Area Limitation: 1.5 x buildable area + (200 Square Feet for R-BI only) = 15,328 maximum square footage • Calculation includes exterior walls, stairway(s) on first level of occurrence, enclosed spaces (finished or unfinished) with a ceiling height of 6 feet or greater, daylighting basements, and enclosed parking (including subterranean) • Calculation does not include subterranean basements. • Covered patios must be open on one side on 1st floor and open on at least two sides above first floor, otherwise area shall be included as floor area. • Required openings for covered patios may include required safety railings and minimal structural supports. Railings shall be constructed of transparent material or opaque material that is at least 40% open. 33. 1 Proposed Floor Area: 8,292.45 square feet PROVIDE THE PREVIOUSLY AGREED UPON SQUARE FOOTAGE EXHIBITS IN THE PLAN SET. THE EXISTING FLOOR AREA IS 5,564 SF PER THE ORIGINAL VARIANCE APPROVAL AND PC1664-1991 REMODEL PLANS. PLEASE CLARIFY ANY DISCREPANCIES SHOWN WITH THE EXISTING FLOOR AREA CALCULATION PROVIDED ON SHEET A025. CORRECT THE BUILDABLE AREA REFERENCED THROUGHOUT THE SET TO MATCH THE PREVIOUS VARIANCE PLANS (10,219SF). REFERENCE THE FLOOR AREA LIMIT AS WELL (BA X 1.5). Please clarify the net addition of floor area versus the existing square footage on the plan set cover sheet. 34. Site (Lot) Coverage Limitation: n/a percent of total lot area • Calculation includes the percentage of a site covered by structures, including eaves and overhangs, and accessory structures and by decks more than 30 inches in height. 35. Proposed Lot Coverage: square feet or percent of total lot area 36. 1 Provide a floor area calculations exhibit (to scale) verifying proposed square footage (show dimensions & calculations). 37. Comments: For 38 - 41, applicable to all single- and two-unit dwellings in the R-1, R-2, and R-BI zoning districts, except: lots 25 feet wide or less in R-2 38. Third Floor Area Limitation (20.48.180.A.2.a) 15% of the total buildable area for lots wider than 30 feet: Maximum: 0.15 x buildable area = Proposed: 20% of the total buildable area for lots 30 feet wide or less: Maximum: 0.20 x buildable area = Proposed: • 39. Comments: 40. Combined Third Floor Area and Covered Deck Limitation (20.48.180.A.2.b) 50% of the total buildable area: Maximum: 0.5 x buildable area = Proposed: 41. Comments: For 42-43, applicable to all single- and two-unit dwellings in the R-1, R-2, R-BI, and RM zoning districts, except: lots 25 feet wide or less in R-2 Residential Zoning Corrections (Cont’d) Updated: 01/20/2021 \\cnb.lcl\data\Users\PLN\Shared\PA's\PAs - 2022\PA2022-0315\PLNG PC2022-3232 CO MKN.docx (pw_CDD) Page 5 of 11 42. 1 Open Volume Area Required (20.48.180.A.3) 15% of the buildable area of the lot in addition to the required setback areas Required: 0.15 x buildable area: 867.15 square feet Proposed: 2,873 square feet • Open volume must be located within the buildable envelope (within the setback; under 24 FEET) • Open Volume must have a minimum dimension of 5 feet in depth from the setback line on which it is located • Open volume must be open on a minimum of one side and have minimum clear vertical dimension of 7.5 feet 43. 1 Comments: Correct the required open volume on A028 to reflect 15% of the buildable area (not 15% of the gross floor area limit). Dimension minimum 5-ft dimension for qualifying open volume spaces on Sheet A028. PLOT PLAN/SITE PLAN/FLOOR PLANS 44. 1 Provide fully dimensioned Site Plan and Floor Plans. Provide a smaller scale site plan so that the entire property is visible. 45. Show the location of all buildings on-site and dimension distance to property lines. 46. 1 Dimension the distance from face of curb to front property line (verify with Public Works). 47. 1 Indicate the second and third floor footprints (if applicable). 48. Dimension all projections (e.g., fireplaces, bay windows, eaves), label distance(s) to property lines. 49. Provide separate existing and proposed floor plans fully dimensioned showing all room uses for all buildings on- site. Existing floor plans shall illustrate walls to be demolished 50. 1 Plot property lines on site plan and all floor plans with setbacks dimensioned. Dimension all setbacks from property line to face of finish of the existing/proposed structure. Setbacks provided appear to be to the eaves? 51. Indicate the location of easement(s) plotted on site plan. 52. 1 Comments: OPEN VOLUME AREAS MUST DEMONSTRATE THEY ARE FULLY OPEN ON AT LEAST ONE SIDE TO NOT COUNT AS GROSS FLOOR AREA (PRE-SUBMITTALS MADE PRIOR TO 2021 CODE UPDATE TO DEFINITION OF GFA). CLARIFY THE LINE OF EXISTING DECKS AND FLOOR AREA ON THE PROPOSED FLOOR PLANS TO CLEARLY IDENTIFY NEW WORK IN RELATION TO EXISTING. Residential Zoning Corrections (Cont’d) Updated: 01/20/2021 \\cnb.lcl\data\Users\PLN\Shared\PA's\PAs - 2022\PA2022-0315\PLNG PC2022-3232 CO MKN.docx (pw_CDD) Page 6 of 11 OFF-STREET PARKING (20.40) Single-Unit Dwellings – Attached 2 per unit in a garage Single-Unit Dwellings – Detached and less than 4,000 sq. ft. of gross floor area* 2 per unit in a garage Single-Unit Dwellings – Detached and 4,000 sq. ft. or greater of gross floor area* 3 per unit in a garage Single-Unit Dwellings – Balboa Island 2 per unit in a garage Two-Unit Dwellings 2 per unit; 1 in a garage and 1 covered or in a garage Other: *Gross Floor Area in this case shall include the square footage of basements, but shall not include the square footage of garages. Minimum Interior Dimensions The minimum interior dimensions for parking spaces in residential zoning districts shall be as provided below (unless otherwise stated in a Planned Community). The Director may approve a reduced width for duplex units when two separate single car garages are proposed side by side and the applicant has proposed the maximum width possible. Lot Width Single Car/Tandem* Two Car Three Car 30 feet or less 9’-3” x 19’ (35’)* 17’-6” x 19’ - 30.1 - 39.99 feet 10’ x 19’ (35’)* 18’-6” x 19’ 26’-9” x 19’ 40 feet or more 10’ x 20’ 20’ x 20’ 28’-3” x 20’ * The minimum depth for a 2-car tandem space is 35 feet 53. Gross Floor Area for purposes of calculating the number of parking spaces: Gross Floor Area (don't include garage) + Basement = 8,292 SF 54. Number of Parking Spaces Required: 3 Minimum interior clear dimensions required: 10' x 20' each 55. Label interior clear dimensions of the garage free of all obstructions such as cabinetry, appliances, steps, posts, etc. (one riser is allowed, maximum 6 inches high, encroaching no more than 18 inches into garage). 56. Indicate on the plans that the garage doors are automatic roll-up doors. Garages with doors that face the street that are located within twenty (20) feet of the front property line are required to be equipped with automatic roll-up doors. 57. Development on lots with alley access shall be designed such that parking is accessed from alley to minimize or eliminate curb cuts. Exceptions permitted only in compliance with Council Policy L-2; and for properties in coastal zone, compliance with Section 21.40.070.B and C required. 58. Comments: HEIGHT LIMITATION (20.30.060) • 20.30.050 Grade Establishment • Measured from average grade if slope is 5% or less • Roofs over the Flat Roof Limit must have a minimum 3:12 pitch • Sloped roofs with a pitch less than 3:12 and parapets, railings, etc are considered flat roof for the purpose of height limits • Heights are measured to the top of all finished materials. • Height certification will be required in some cases 59. Flat Roof Limit: 24 feet Sloped Roof Allowable Ridge Height: 29 feet 60. Height certification inspection required? Yes No If so, add note to elevations stating Height Certification Required. Residential Zoning Corrections (Cont’d) Updated: 01/20/2021 \\cnb.lcl\data\Users\PLN\Shared\PA's\PAs - 2022\PA2022-0315\PLNG PC2022-3232 CO MKN.docx (pw_CDD) Page 7 of 11 61. Provide topographic survey (stamped and signed by a licensed surveyor) to establish slope and average grade or, use subdivision grading plan, if applicable. 62. 1 Provide a sheet showing the outline of the proposed structure over a topographic survey to verify determination of slope and grade to be used for measuring height. 63. 1 Provide slope of the lot. The slope of a lot shall be determined using a four-sided polygon that most closely approximates the actual footprint of the proposed structure. The area of the four-sided polygon shall not be smaller than the footprint of the proposed structure and shall be located entirely within the buildable area of the lot. Identify the elevation points from survey and distance used to calculate slope. 64. Establishment of Grade (Five Percent or Less Slope)- The grade of the surface from which structure height is measured shall be a plane established using the average of the elevations at each corner of the four-sided polygon. Example: A + B + C + D = X; X/4 = Established grade elevation from which to measure structure height. Identify the four points used to determine grade plane on site plan and illustrate average grade calculation. 65. 1 Establishment of Grade (More than Five Percent Slope)- The established grade from which structure height is measured shall be a plane established by determining the elevation of the lot at five evenly spaced points along each of the two side property lines and connecting each of the points along a side property line with the corresponding point on the opposite side property line. The five evenly spaced points along each side property line shall be located so that one point is located at the intersection of the front setback line with the side property line and another point is located at the intersection of the rear setback line with the side property line. The other three points along the side property line shall be located so that all five points are equidistant from each other. Provide a grade plane exhibit per the methodology above and clearly identify the survey points used to establish the grade plane. THE GRADE PLANE EXHIBIT PROVIDED ON SHEET A026 DOES NOT MATCH THE PREVIOUSLY AGREED TO POINTS FOR THE DETERMINATION OF HEIGHT COMPLIANCE FOR THIS PROPERTY. PLEASE INCLUDE THAT GRADE EXHIBIT IN THIS PLAN SET. 66. 1 Label the established grade on all elevation sheets. 67. 1 For lots with a more than 5 percent slope, plot roof plan over established grade plan exhibit to assist with determination of grade points located directly below ridge peaks, roof areas and/or parapets. 68. 1 Label interpolated grade points (based on established grade plane) below any critical ridge, parapet, etc. 69. 1 Dimension heights from established grade to: top of flat roof ridge peak all roof top equipment deck rails any flat elements CHIMNEYS 70. All new structures shall have a minimum top of slab elevation of 9.0 (88 NAVD datum) pursuant to Section 20.30.060.B.3. When the top of slab is required to be raised, the height of the principal building shall be measured from the 9.0 (88 NAVD datum) elevation. 71. 1 Provide a complete roof plan. CLARIFY EXISTING AND NEW ROOFLINES ON THE ROOF PLAN. 72. 1 Label roof pitches on roof plan and elevations. 73. Label and dimension eave overhang to property line on all exterior elevations. Residential Zoning Corrections (Cont’d) Updated: 01/20/2021 \\cnb.lcl\data\Users\PLN\Shared\PA's\PAs - 2022\PA2022-0315\PLNG PC2022-3232 CO MKN.docx (pw_CDD) Page 8 of 11 74. 1 Comments: OVERLAY THE ROOF PLAN OVER THE GRADE PLANE. PROVIDE CRITICAL ROOFLINE/DECK ELEVATIONS AND CORRESPONDING EXISTING GRADE ELEVATIONS TO CONFIRM COMPLIANCE WITH THE HEIGHTLIMIT. 2:12 PITCH IS PROPOSED, DEMONSTRATE IT IS UNDER THE 24-FT FLAT ROOF HEIGHT LIMIT. CLARIFY THE SCOPE OF WORK FOR THE ROOF AREA. IN WHAT AREAS WILL EXISTING FRAMING BE REPLACED? I PRESUME THE ROOFING MATERIAL WILL ALSO BE REPLACED? THE NOTE, "EXISTING ROOF TO REMAIN" ON THE ROOF PLAN APPEARS TO BE A MISNOMER. IDENTIFY THE CURB HEIGHT ELEVATIONS FROM THE TOPOGRAPHIC SURVEY ON THE ROOF PLAN AND SITE PLAN. SHOW THE LINE OF ESTABLISHED GRADE ON THE EXTERIOR ELEVATIONS ON EACH SIDE WITH THE 5 POINTS FROM THE AGREED UPON GRADE EXHIBIT IN THE SET. REMOVE THE PROPOSED FABRIC AWNINGS FROM THE EXTERIOR ELEVATIONS THAT PROJECT BEYOND THE ENVELOPE OF THE EXISTING DEVELOPMENT. EXCEPTIONS TO HEIGHT LIMITS (20.30.060 D) 75. 1 Interior Fireplaces- The overall chimney height for an interior fireplace is permitted to exceed the height limit by two feet above the roof plane plus an additional two foot maximum for the cap/spark arrestor. The additional two foot section is not only limited in height but also to 2 feet by 4 feet in width and depth. In addition, the chimney must be located a minimum distance of 10 feet from the nearest roof plane. Label dimensions of the chimney plus any portion of the cap/arrestor. CHIMNEYS ARE LIMITED TO THE CURB HEIGHT AT OCEAN BLVD. PER SECTION 20.30.060 (HEIGHT LIMITS AND EXCEPTIONS(B)(4) (HEIGHT LIMIT AND EXCEPTIONS, HEIGHT OF STRUCTURES AND MEASUREMENT, STRUCTURES ON OCEAN BLVD.) 76. Elevator Shafts/Enclosed Stairwells- Flat roofs above elevator shafts and enclosed stairwell housings may exceed the allowed height limit up to the maximum height for a sloped roof, provided they do not exceed thirty (30) square feet in area. Label applicable elevator shaft/enclosed stairwell dimensions and area. 77. Comments: LANDSCAPING Residential Zoning Corrections (Cont’d) Updated: 01/20/2021 \\cnb.lcl\data\Users\PLN\Shared\PA's\PAs - 2022\PA2022-0315\PLNG PC2022-3232 CO MKN.docx (pw_CDD) Page 9 of 11 78. 1 LANDSCAPING – TITLE 14 Chapter 14.17 of the Municipal Code (Water-Efficient Landscaping) applies to landscape installation projects requiring a ministerial or discretionary permit and exceed the following thresholds: 1. New landscape project with greater than 500 square feet of landscape area 2. Rehabilitated landscaped project with greater than 2,500 square feet of landscape area New Landscape Project: total sq ft of new landscaped area Provide Landscape Documentation Package prepared in accordance with Design Standards or, if landscape area is 2,500 square feet or less, comply with the Prescriptive Compliance Option (Appendix H of Design Standards). Rehabilitated Landscape Project: total sq ft of rehabilitated landscaped area 1. Provide Landscape Documentation Package prepared in accordance with Design Standards or; 2. Rehabilitated projects with replacement plantings with equal or less water need than the existing landscaping and the irrigation system is designed, operable and programmed to comply with the City’s water conservation regulations are exempt from the ordinance and the requirement to provide a complete landscape documentation package. To qualify for this exemption, the applicant must provide a landscape and irrigation plan and letter from a licensed professional stating that the replacement landscaping and irrigation system complies with the terms of this exemption. 79. 1 Comments: INDICATE THE TOTAL SQUARE FOOTAGE OF NEW/REHABILITATED LANDSCAPING UNDER THE PROPOSED PROJECT TO DETERMINE COMPLIANCE UNDER THE WATER-EFFICIENT LANDSCAPE REQUIREMENTS OF CHAPTER 14.17 OF THE NBMC. REFER TO THE ATTACHED CHECKLIST OF SUBMITTAL REQUIREMENTS. 80. LANDSCAPING – TITLE 20 (20.36.050A) Impervious surfaces in R-1 and R-2 zones. 1. Impervious surface areas, excluding driveways, shall not exceed 50 percent of the front yard area with the remaining area landscaped with plant material. The use of pervious materials for walkways, porches, and outdoor living areas is allowed. 2. Where the typical neighborhood pattern of front yards has been developed with hardscaped outdoor living areas that exceed the 50 percent maximum for impervious surfaces the Director may waive this requirement. Project complies with: No.1 Yes No No.2 Yes No 81. 1 Comments: PROVIDE AN OVERALL PLANTING PLAN FOR THE ENTIRE SITE ON ONE SHEET (NOT BY LEVEL). REMOVE THE 36" BOX MARINA STRAWBERRY TREES PROPOSED WITHIN THE 10' FRONT SETBACK AREA. THE ANTICPATED GROWTH HEIGHT OF THIS VEGETATION MAY POSE A CONFLICT WITH PUBLIC VIEWS FROM OCEAN BOULEVARD AT THIS LOCATION. (SEE SHEET L504 FOR EXAMPLE) DESIGN CRITERIA (20.48.180 B.) For 78-83 below, applicable to all single-unit and two-unit residential building citywide 82. Walls: Long unarticulated exterior walls are discouraged on all structures. The visual massing of a building should be reduced by incorporating appropriate design elements; including variation in the wall plane, building modulation, opening, recesses, vertical element, varied textures, and design accents (e.g. moldings, pilasters, etc.). Front facades shall include windows. Residential Zoning Corrections (Cont’d) Updated: 01/20/2021 \\cnb.lcl\data\Users\PLN\Shared\PA's\PAs - 2022\PA2022-0315\PLNG PC2022-3232 CO MKN.docx (pw_CDD) Page 10 of 11 83. Upper floors: Portions of upper floors should be set back in order to scale down facades that face the street, common open space, and adjacent residential structures. Upper story setbacks are recommended either as full length “stepbacks” or partial indentations for upper story balconies, decks, and/or aesthetic setbacks. 84. Architectural treatment: Architectural treatment of all elevations visible from public places, including alleys, is encouraged. Treatments may include window treatments, cornices, siding, eaves, and other architectural features. 85. Front façade: Where the neighborhood pattern is for the primary entrance to face the street, the primary entry and windows should be the dominate elements of the front façade. Primary entrances should face the street with a clear, connecting path to the public sidewalk or street. Alternatively, entry elements may be visible from the street without the door necessary facing the street. 86. Main entrance: The main dwelling entrance should be clearly articulated through the use of architectural detailing. 87. Comments: MISCELLANEOUS ITEMS 88. TWO- TO FOUR-UNIT DWELLING PROJECTS A notice shall be signed by property owners and copied into the plan set prior to the issuance of a building permit for development of two- to four-unit dwellings. The notice serves as a record of acknowledgement that property owners understand should they choose to pursue the approval of a Parcel Map for condominium purposes during the construction, they fully understand that the Parcel Map application is a discretionary process and is not guaranteed. 89. CONDOS - (Existing Structures) Before a condominium unit may be sold, a condominium conversion building permit must be signed off by the Planning Department. The Parcel Map must be signed off by the Public Works Department, approved by the County and RECORDED at the County. Proof of recordation will be required before Planning can sign off on the building permit final. Provide a copy of the first page of the recorded document. 90. CONDOS - (New Structures) Before a condominium unit may be sold, a building permit is required for a description change from “duplex” to “condominiums.” Before building permits can be finaled, the Parcel Map must be signed off by the Public Works Department, approved by the County and RECORDED at the County. Proof of recordation will be required before Planning can sign off on the description change. Provide a copy of the first page of the recorded document. 91. 20.30.130 (Traffic Safety Visibility Area): Design includes accessory improvements and/or landscaping within traffic safety visibility triangle: Yes No • If Yes, label and illustrate traffic safety visibility triangle as follows: • Label proposed improvements and heights within triangle as follows: 92. 20.30.020.A (Screening of Roof-Mounted and Ground-Mounted Mechanical Equipment)- The screening of mechanical equipment is required in all zoning districts at the time of new installation or replacement. Roof- mounted and ground-mounted mechanical equipment (e.g., air conditioning, heating, ventilation ducts and exhaust vents, swimming pool and spa pumps and filters, transformers and generators, and similar equipment, but excluding solar collectors and related equipment), shall be screened from public view and adjacent residential districts, and shall comply with the requirements: 93. 1 ACCESSORY STRUCTURES Accessory structures, including fences, hedges, walls, and retaining walls, are typically limited to 6 feet in side and rear setbacks and 42 inches in front setbacks. Please label height from natural grade below to highest point of structure. CONSISTENTLY SHOW TOP OF WALL AND EXISTING GRADE ELEVATIONS FOR ALL PROPOSED SITE WALLS ON THE ARCHITECTURAL SITE PLAN, LANDSCAPE PLANS, AND CIVIL GRADING PLANS. SOME PROPOSED SITE WALLS APPEAR TO BE MISSING ENTIRELY FROM THE CIVIL PLANS. BE SURE TO INCLUDE FINISHED SURFACE AND EXISTING GRADE ELEVATOINS FOR THE PROPOSED COURTYARD AREAS AS WELL. INCLUDE TOP OF CURB ELEVATION POINTS TO IDENTIFY COMPLIANCE WITH THE HEIGHT LIMIT ALONG OCEAN BOULEVARD AS WELL. 94. FYI ASSOCIATION APPROVAL (ADVISORY) Issuance of a Building Permit by the City does not relieve applicant of legal requirement to observe covenants, conditions and restrictions which may be recorded against the property or to obtain community association approval of plans. 95. TRASH AREA Indicate the location of the screened trash area on the site plan or floor plan. Residential Zoning Corrections (Cont’d) Updated: 01/20/2021 \\cnb.lcl\data\Users\PLN\Shared\PA's\PAs - 2022\PA2022-0315\PLNG PC2022-3232 CO MKN.docx (pw_CDD) Page 11 of 11 96. Comments: GENERAL NOTES 97. 1 Add the following note(s) as indicated below: “Pools, spas, walls, fences, patio covers and other freestanding structures require separate reviews and permits.” “Fences, hedges, walls, retaining walls, guardrails and handrails or any combination thereof shall not exceed 42 inches from existing grade prior to construction within the required front setback area(s).”DIMENSION GUARDRAILS HEIGHTS AS WELL AS RETAINING WALL HEIGHTS IN 10-FT FRONT SETBACK. Accessory Living Areas- “There shall be no facilities used for food preparation within or be used for residential purposes separately or independently from occupants of principal structure.” Other:- HOLD ON FINAL 98. FYI The following Hold(s) on Final will be applied to your building permit: Height Certification of critical roof height elevations. Condominium Conversions- Parcel Map recordation. New Condominiums (1-4 units) - Parcel Map recordation and issuance of Description Change permit Landscape Certification- For projects requiring landscape documentation package, applicant must provide third- party stamped and signed Certificate of Completion (Appendix E of Design Standards), Third Party Audit, and Post-Installation Irrigation Schedule and Maintenance Schedule. Accessory Dwelling Units: Deed Restriction and Affordability Questionnaire Other:- 99. Comments: PROVIDE CUT/FILL CY CALCULATIONS FROM THE GRADING PLAN ON THE CUT/FILL EXHIBIT AS WELL FOR CLARITY AND EASE OF REFERENCE. F:\Users\PLN\Shared\Official Documents\Design Guidelines Rev: 08-26-2016 Chapter 14.17 Water-Efficient Landscape Ordinance Checklist of Applicability/Submittal Requirements Chapter 14.17 (Water-Efficient Landscape Ordinance) promotes the design, installation, and maintenance of landscaping in a manner that conserves regional water resources by ensuring that landscaping projects are not unduly water-needy and that irrigation systems are appropriately implemented to minimize water waste. The City’s ordinance is consistent with the requirements mandated by State Law. Refer to the Landscape Design Standards (https://newportbeachca.gov/home/showdocument?id=7710) for comprehensive information about the submittal requirements and copies of the appendices referenced. Please see the thresholds below and reference the applicable exhibit (attached) for plan submittal requirements. Applicability a. Exempt [See Exhibit A] • 500 square feet for a “new landscaping project”; OR • Rehabilitated Landscape Project - projects that consist of replacement plantings with lower water needs and the irrigation system is designed, operable, and programmed to comply with City water conservation regulations. Letter or documentation from a Licensed Professional required. • Hazard Reduction and Fuel Modification zones where Fire Prevention Guidelines, G.01 and G.02 shall prevail b. Prescriptive Compliance [See Exhibit B] • Qualifying projects include <2500 square feet of new planting areas (new landscape projects and rehabilitated landscaping projects. c. Landscape Documentation Package [See Exhibit C] • >2,500 square feet of new or rehabilitated landscaping project Glossary “New landscape project” New landscape installation project: a landscape installed in conjunction with new development, whether or not the new development includes construction of new building(s). (e.g. parks, playgrounds, and greenbelts). “Rehabilitated landscape project” Landscape rehabilitation project: any re- landscaping project that meets the criteria of Section 14.17.020 (Applicability), where the modified landscape area is greater than 2,500 square feet. “Landscape area” all the planting areas, turf areas, and water features (including pools, ponds, fountains, etc.) in a Landscape Design Plan which are subject to, and must be included in, the Maximum Applied Water Allowance and Estimated Applied Water Use calculations. The landscape area does not include footprints of buildings or structures, sidewalks, driveways, parking lots, decks, patios, gravel or stone walks, other pervious or non-pervious hardscapes, and other non-irrigated areas designated for nondevelopment (e.g., open spaces and existing native vegetation). Checklist Submittal Requirement Exhibits A: Exempt B: Prescriptive Compliance C: Landscape Documentation Package F:\Users\PLN\Shared\Official Documents\Design Guidelines Rev: 08-26-2016 Exhibit A – Exempt Projects Checklist/Submittal Requirements Site Address: ________________________ Project Landscape Area (square feet): _____________________ (<500 square feet) Does your project include less than 500 square feet of new or rehabilitated landscape area? ___ Yes ___ No If you answered yes above, please indicate the landscape square footage on the project plans and the project is exempt from any further requirements. If you answered no above, please continue onto the applicability questions, below. Applicability: 1) Does your project consist of replacement plantings with equal or lower water needs; and the irrigation system is designed, operable and programmed to comply with the City’s water conservation regulations? ___ Yes ___ No 2) Is your project site a registered local, state, or federal historic site? ___ Yes ___ No 3) Is your project an ecological restoration project that does not require a permanent irrigation system? ___ Yes ___ No 4) Is your project a plan collection as a part of botanical gardens and arboretums open to the public? ___ Yes ___ No 5) Is your landscape project in a Hazard Reduction or Fuel Modification Zone? ___ Yes ___ No If you answered yes to any of the above, proceed to Exempt Project Submittal Requirements, below. Replacement Plantings, Submittal Requirements: Submittal Items (All submittal items must be inserted into the plan set): Sheet # 1. Project information: date, project name, project address and/or lot number(s), contact information for the project applicant and property owner ____ 2. Total landscape area (square feet) ____ 3. If answered yes to number 1 under the applicability section, please provide a letter or documentation from a licensed professional to demonstrate the project’s lower water needs. ____ F:\Users\PLN\Shared\Official Documents\Design Guidelines Rev: 08-26-2016 Exhibit B – Prescriptive Compliance Option Checklist/Submittal Requirements Applicability:  New or rehabilitated projects landscape projects (including new single-family, multifamily, public, institutional or commercial projects) with an aggregate landscape area equal to or greater than five hundred (500) square feet but less than 2,500 square feet.  Graywater or rainwater on-site capture with less than 2,500 sq. ft. of landscape area Preparation by a Licensed Professional is not required for the Prescriptive Compliance Option. Refer to the Landscape Design Standards (Appendix H) for comprehensive information about submittal requirements and copies of the appendices referenced below. Prescriptive Compliance Submittal Requirements: Sheet # (All submittal items must be inserted into the plan set): 1. Project information: Date, project name, project address and/or lot number(s), total landscape area (square feet), project type, water supply type, contact information for the project applicant and property owner ____ 2. Written notes/confirmation that: Turf area does not exceed 25% of landscape planting area (prohibited on slope areas and parkways less than 10 feet wide) 75% of landscape area must be plated with climate adapted plants with an average WUCOLS plant factor of 0.3. Compost at a rate of four cubic yards per 1,000 square feet to a depth of six inches 3-inch mulch layer applied to all planting areas (excluding turf areas) Automatic irrigation controllers will use evapotranspiration or soil moisture sensor data and will have manual shut-off valves _____ 3. Written statement: “I agree to comply with the requirements of the prescriptive compliance option to the MWELO.” ____ Certification of Completion Package (Prior to final):  Landscape Installation Certificate of Completion (Appendix E)  Irrigation audit report (Appendix G) or enrollment in a regional or local water suppliers water conservation program  Post installation irrigation schedule and landscape/irrigation maintenance schedule F:\Users\PLN\Shared\Official Documents\Design Guidelines Rev: 08-26-2016 Exhibit C – Landscape Documentation Package Checklist/Submittal Requirements Applicability: A Landscape Documentation Package is required for landscape projects with 2,500 square feet or greater of new or rehabilitated landscape. Refer to the Landscape Design Standards for comprehensive information about the submittal requirements and copies of the appendices referenced below. Landscape Documentation Package Submittal Requirements: Submittal Items (All submittal items must be inserted into the plan set): Sheet No. 1. Project information: date, project name, project address and/or lot number(s), total landscape area (square feet), project type, water supply type, contact information for the project applicant and property owner ____ 2. Certification of Landscape Design (Appendix B) ____ 3. Water Efficient Landscape Worksheet (Appendix C and Appendix D) ____ 4. Soil Management Report – An analysis by a certified agronomic soils lab, which may include soil texture, infiltration rate, pH, soluble salts, sodium, % of organic matter, and recommendations ____ 5. Landscape Design Plan ____ 6. Irrigation Design Plan ____ 7. Hydrozone Plan ____ 8. Grading Design Plan ____ 9. Landscape Documentation Package Checklist (this page) ____ 10. The statement: “Hold on final for submittal of Certification of Completion Package.” ____ Certification of Completion Package (Prior to final):  Landscape Installation Certificate of Completion (Appendix E)  Irrigation audit report (Appendix G) or enrollment in a regional or local water suppliers water conservation program  Post installation irrigation schedule and landscape/irrigation maintenance schedule F:\Users\PLN\Shared\Official Documents\Design Guidelines Rev: 08-26-2016 Water-Efficient Landscape Ordinance (WELO) Compliance Process Plan Check Document Compliance (or exemption) Permit Issuance Construction Pre- Final Certification of Completion Due (HOLD ON FINAL) Final Permits Occupancy Tmplt: 06/07/19 P ROJECT R EVIEW R EQUES T C O M M U N I T Y D E V E L O P M E N T D E P AR T M E N T Planning Division Please Distribute to: BLDG – E. Skarin PW- D. Keely Fire – J. Gillepsie Date: January 24, 2023 Please return PRR and Plans to Staff Planner Makana Nova, Senior Planner 949-644-3249, mnova@newportbeachca.gov Applicant: Sara Pijuan, KAA Design Group 310-821-1400, spijuan@kaadesigngroup.com Contact: Gregg Ramirez, 949-338-1795 gbrplanning@outlook.com Project Name Dawson Residence CDP Address: 2741 Ocean Boulevard (PA2022-0315) Coastal Development Permit Request for approval of a coastal development permit to allow additions and alterations to an existing non-conforming 5-level single-family residence with a two-car garage and single car garage. Two additional garage spaces slightly smaller than the code minimum yet large enough to reasonable accommodate most vehicles are also provided as part of the existing home. The addition is 2,511 net square feet to the existing 5,781 square foot home. The resulting home will be 8,292 square feet on the existing 10,360 square foot residential lot. The project includes grading, hardscape, drainage, a swimming pool, landscaping, and other accessory structures. The preliminary grading plan shows 1,020 cubic yards of cut and export of cut to accommodate the remodel to the existing home. REPORT REQUESTED BY: Monday, February 6, 2023 Zoning Administrator Hearing Date: TBD Check all that apply: ❑ No comments on the project as presented. Notes: 1. Property is located in a landslide hazard area. Provide soils report which complies with minimum requirements in Building Code Policy CBC 1803.5. 2. Provide designs for prestressed soil anchors and permanent shoring that comply with requirements in CBC 1811 and CBC 1812. Maximum permissible lateral displacements are limited to 1”. 3. Show on precise grading plan locations and descriptions of existing public and private utilities beneath Ocean Boulevard which may be affected by (1) lateral movement during and after construction of prestressed soil anchors and permanent shoring, and (2) excavation and/or caisson drilling equipment staged on or adjacent to the street. X Application of Standard Code requirements are not expected to alter the project design. ❑ Recommended conditions of approval are attached. ❑ Application of Standard Code requirements or the attached conditions of approval will substantially impact or alter the design of the project. ❑ I contacted the applicant on ❑ To schedule an appt. for Code review ❑ To discuss the following (see notes) Tmplt: 06/07/19 4. Provide on plans the determination of the required construction type for the building based on proposed building (1) height, (2) number of stories and (3) fire sprinkler system (CBC 504). 5. The Water Quality Management Plan shall be submitted to the Building Division engineering geologist for review. 6. Emergency escape and rescue openings will be required from non-habitable basement areas with more than 200sf of floor area. 7. Building shall comply with fire and life safety provisions according to the 2022 California Residential Code. 8. Emergency escape and rescue openings opening on to decks or roofs will require that a Request for Alternate Method of Construction be submitted for review during Building Division plan check. These requests typically require that the deck or roof assemblies be constructed as minimum 1-hour fire rated assemblies. 9. Side yard terraces serving emergency escape and rescue openings shall include ladders to facilitate egress to public way required per code. 10. 30-days notice shall be provided to adjacent neighbors prior to start of excavation for slope work or required shoring where the depth of the excavation is greater than the distance from the property line to the edge of the excavation. Eric Skarin 3270 02/06/23 Signature Ext. Date Tmplt: 06/07/19 P ROJECT R EVIEW R EQUES T C O M M U N I T Y D E V E L O P M E N T D E P AR T M E N T Planning Division Please Distribute to: BLDG – T. Thai PW- D. Keely Fire – J. Gillepsie Date: January 24, 2023 Please return PRR and Plans to Staff Planner Makana Nova, Senior Planner 949-644-3249, mnova@newportbeachca.gov Applicant: Sara Pijuan, KAA Design Group 310-821-1400, spijuan@kaadesigngroup.com Contact: Gregg Ramirez, 949-338-1795 gbrplanning@outlook.com Project Name Dawson Residence CDP Address: 2741 Ocean Boulevard (PA2022-0315) Coastal Development Permit Request for approval of a coastal development permit to allow additions and alterations to an existing non-conforming 5-level single-family residence with a two-car garage and single car garage. Two additional garage spaces slightly smaller than the code minimum yet large enough to reasonable accommodate most vehicles are also provided as part of the existing home. The addition is 2,511 net square feet to the existing 5,781 square foot home. The resulting home will be 8,292 square feet on the existing 10,360 square foot residential lot. The project includes grading, hardscape, drainage, a swimming pool, landscaping, and other accessory structures. The preliminary grading plan shows 1,020 cubic yards of cut and export of cut to accommodate the remodel to the existing home. REPORT REQUESTED BY: Monday, February 6, 2023 Zoning Administrator Hearing Date: TBD Check all that apply: ❑ No comments on the project as presented. Notes: 1) Residential fire sprinkler system (NPFA 13D) may be required by Newport Beach Building Department 2) Emergency Escape and Rescue windows shall be provided where required by the California Fire Code, California Building Code and California Residential Code. X Application of Standard Code requirements are not expected to alter the project design. ❑ Recommended conditions of approval are attached. ❑ Application of Standard Code requirements or the attached conditions of approval will substantially impact or alter the design of the project. ❑ I contacted the applicant on ❑ To schedule an appt. for Code review Tmplt: 06/07/19 ❑ To discuss the following (see notes) Signature Ext. Date Tmplt: 06/07/19 P ROJECT R EVIEW R EQUEST C O M M U N I T Y D E V E L O P M E N T D E P A R T M E N T Planning Division Please Distribute to: BLDG – T. Thai PW- D. Keely Fire – J. Gillepsie Date: January 24, 2023 Please return PRR and Plans to Staff Planner Makana Nova, Senior Planner 949-644-3249, mnova@newportbeachca.gov Applicant: Sara Pijuan, KAA Design Group 310-821-1400, spijuan@kaadesigngroup.com Contact: Gregg Ramirez, 949-338-1795 gbrplanning@outlook.com Project Name Dawson Residence CDP Address: 2741 Ocean Boulevard (PA2022-0315) Coastal Development Permit Request for approval of a coastal development permit to allow additions and alterations to an existing non-conforming 5-level single-family residence with a two-car garage and single car garage. Two additional garage spaces slightly smaller than the code minimum yet large enough to reasonable accommodate most vehicles are also provided as part of the existing home. The addition is 2,511 net square feet to the existing 5,781 square foot home. The resulting home will be 8,292 square feet on the existing 10,360 square foot residential lot. The project includes grading, hardscape, drainage, a swimming pool, landscaping, and other accessory structures. The preliminary grading plan shows 1,020 cubic yards of cut and export of cut to accommodate the remodel to the existing home. REPORT REQUESTED BY: Monday, February 6, 2023 Zoning Administrator Hearing Date: TBD Check all that apply:  No comments on the project as presented. Notes: Corrections: 1-The existing wall located partially within the Way Lane public right of way shall be relocated entirely on private property. The proposed project is proposing to construct a new pool directly behind the existing wall. 2-The existing and proposed new doors adjacent to the Way Lane right of way shall be modified so that the door swing does not projcet into the right of way. 3-The proposed encroachment along the Ocean Boulevard frontage shall be pulled back and located entirely on private property. 3-Add growth characteristics to the landscaping plans. Planting shall comply with the existing Restrictive Covenant and Agreement. David Keely 3349 2/8/23 Signature Ext. Date  Application of Standard Code requirements are not expected to alter the project design.  Recommended conditions of approval are attached.  Application of Standard Code requirements or the attached conditions of approval will substantially impact or alter the design of the project.  I contacted the applicant on  To schedule an appt. for Code review  To discuss the following (see notes) DAWSON RESIDENCE a KAA Design company 08/15/19 PLANNING EXHIBITEVENS ARCHITECTS 01 - GRADE PLANE - PLAN WITH SURVEY SCALE: 1/8" = 1'-0" 4/ 1 5/ 2 01 6 N 0 4'8'16' 02 02 01 07 04 10 62' 52' 44' 19' 12' 66' 55' 41' 28' 21'