Loading...
HomeMy WebLinkAboutPA2023-0051_20230222_Hydrology Report dated 2-07-2023 HYDROLOGY STUDY FOR TRACT 907, LOT 473 APN 423-172-08 413 Via Lido Soud NEWPORT BEACH, CA 92663 Feb 7, 2023 PREPARED BY Core Civil Engineering, Inc 23172 Plaza Pointe Drive, $145 Laguna Hills, CA 92653 (949)954-7158 HYDROLOGY STUDY INTRODUCTIOIN The hydrology study presented in this report discusses the design criteria and methodology utilized for the hydrologic analysis of the subject property. The design criteria and methodology used in this study follow the Orange County Hydrology Manual. The 2-yr, 24- hour precipitation depths specified in the Orange County Hydrology Manual are used for hydrologic analysis of the 2-year, 24-hour storm. RATIONAL METHOD Runoff calculations for this study were accomplished using the Rational Method. The Rational Method is a physically based numerical method where runoff is assumed to be directly proportional to rainfall and area, less losses for infiltration and depression storage. Flows were computed based on the Rational formula: Q= CIA Where Q = peak discharge (cfs) C = Runoff coefficient based on land use and soil type I = Rainfall intensity (in./hr.) A = Watershed area (acre) The runoff coefficient represents the ratio of rainfall that runs off the watershed versus the portion that infiltrates to the soil or is held in depression storage. The runoff coefficient is dependent on the land use coverage and soil type. For a typical drainage study, rainfall intensity varies with the watershed time of concentration. The watershed time of concentration at any given point is defined as the time it would theoretically take runoff to travel from the most upstream point in the watershed to a concentration point, as calculated by equations in the Orange County Hydrology Manual. DRAINAGE AREA For this project, a total of one drainage area (DMA #1) was utilized for hydrology study of the subject property. DMA #1 Existing Conditions Total Area (sq. ft.) Total Impervious Area (sq. ft.) Total Pervious Area (sq. ft.) Length of Initial Area, L (ft.) Difference in Elevation b/w Ends of Initial Area, H (ft.) 3,602 (0.08 acre) 3,480 0 90 1.94 ft. Difference in elevation ends of initial area, H = 1.94 ft. From Figure D-1, Orange County Hydrology Manual Time of Concentration Tc = 5.8 min. From Figure B-3 for return frequency 2 yr. Intensity I(t) = atb = (5.702)(5.8-0.574) = 2.08 in/hr. Q = CIA Where Q = Runoff in cubic feet per second (cfs) C = Runoff coefficient representing the ratio of runoff to rainfall I = The time-averaged rainfall intensity in in./hr. corresponding to the time of concentration A = Drainage area in acre C = 0.9 (Ai + (I – Fp)Ap/I) for I > Fp C = 0.9Ai for I < Fp Where Fp = Infiltration rate (0.4-Soil Group A, 0.3-Soil Group B, 0.25-Soil Group C, 0.20-Soil Group D. Ai = Ratio of impervious area to total area Ap = Ratio of previous area to total area, Ap = 1-Ai C = 0.9 Q1exist(2yr.) = 0.9 x 2.08 x 0.08 = 0.15 cfs Proposed Conditions Total Area (sq. ft.) Total Impervious Area (sq. ft.) Total Pervious Area (sq. ft.) Length of Initial Area, L (ft.) Difference in Elevation b/w Ends of Initial Area, H (ft.) 3,602 (0.08 acre) 3,480 122 90 2.72 ft. Difference in elevation between ends of initial area, H = 2.72’ From Figure D-1, Orange County Hydrology Manual Time of Concentration Tc = 5.5 min. From Figure B-3 for return frequency 2 yr. Intensity I(t) = atb = (5.702)(5.5-0.574) = 2.14 in/hr. Q = CIA Where Q = Runoff in cubic feet per second (cfs) C = Runoff coefficient representing the ratio of runoff to rainfall I = The time-averaged rainfall intensity in in./hr. corresponding to the time of concentration A = Drainage area in acre C = 0.9 (Ai + (I – Fp)Ap/I) for I > Fp C = 0.9Ai for I < Fp Where Fp = Infiltration rate (0.4-Soil Group A, 0.3-Soil Group B, 0.25-Soil Group C, 0.20-Soil Group D. Ai = Ratio of impervious area to total area Ap = Ratio of previous area to total area, Ap = 1-Ai C = 0.9 Q1new(2yr.) = 0.9 x 2.14 x 0.08 = 0.154 cfs n= 0.009 for pvc pipe V= (1.49/0.009) x (R) 2/3 x (S) 1/2 ft/sec Q= V x Ap cfs A= 0.087 R=0.083 S=0.01 V= (1.49/0.009) x (0.083) 2/3 x (0.01) 1/2 = 3.15 Q= 3.15 x 0.087 Q= 0.274 cfs > 0.154 cfs OK for 4” PVC pipe with 1% slope