Loading...
HomeMy WebLinkAboutPA2023-0051_20230412_Incomplete Letter_ COMMUNITY DEVELOPMENT DEPARTMENT PLANNING DIVISION 100 Civic Center Drive, P.O. Box 1768, Newport Beach, CA 92658-8915 949-644-3200 www.newportbeachca.gov NOTICE OF INCOMPLETE COASTAL DEVELOPMENT PERMIT APPLICATION FILING April 12, 2023 David R. Olson Architects Attn: Stephen Wan 9 Jenner, Suite 290 Irvine, CA 92618 Application No. • Coastal Development Permit (PA2023-0051) Address 413 Via Lido Soud Please be advised that after reviewing the subject application, your submittal has been deemed incomplete and further information is required before we are able to proceed with the application process. The following documentation is required to complete the application: 1. Property Development Standards. Please be advised, the project as designed does not comply with all required property development standards identified in Newport Beach Municipal Code (NBMC) Chapter 21.30 (Property Development Standards). Reference the attached plan check correction sheet for a list of the required changes. 2. Plant Selection and Grouping. Please provide a detailed planting plan in accordance with Newport Beach Municipal Code (NBMC) Section 21.30.075(3) (Landscaping – Plant Selection and Grouping) and Section 21.30.085 (Water Efficient Landscaping). Refer to the California Invasive Plant Council and California Native Plant Society websites for a list of prohibited and drought tolerant plant types for environmentally sensitive areas. 3. Notice of Public Hearing. Please provide the Excel file for the mailing labels. Refer to the Public Hearing Requirements for formatting. April 12, 2023 PA2023-0051 Page 2 Tmplt. 10/23/2018 4. Preliminary Geotechnical Report. As this property is located within a coastal hazards area subject to liquefaction, please provide a copy of the preliminary geotechnical report for this project. 5. Block Wall The coastal hazards report concludes that a site block wall can be built along site property lines to elevation of +14.4’NAVD88. The current site shows a wall. If the existing block wall is to remain, submit a Bulkhead condition report. The report is required to be prepared by in accordance with Newport Beach Municipal Code Section 21.30.015(E)(3). In addition to the other requirements the report must include an analysis of whether the existing bulkhead is required to protect the existing principal structure. If the existing wall is to be removed, a bulkhead built to +10.9’NAVD88 (with adaptability up to +14.1’NAVD88) as concluded in the coastal hazards report must be provided. Show this proposed block wall on the plans with top of wall elevations. 6. Please be aware, a Waiver of Future Protection will likely be required as a condition of approval for this project in accordance with Section 21.30.015(E)(5). This is a recorded agreement waiving any potential right to future protection devices to address threats from natural hazards for the economic life of the development. 7. Public Works Review See attachments for Public Works review and markups and address all comments. 8. Building Review See attachments for Building review and comments. Comments may be addressed during the building permit review. 9. Notice of Application Filing A Notice of Application Filing must be posted on site at a conspicuous place, easily readable by the public and placed as close as possible to the site of the proposed development. A copy of the notice can be picked up at the office front counter. Please arrange with me by email at jtran@newportbeachca.gov to pick-up a copy from the office. Once posted on-site, submit a photo of the posting with clear location either by email to jtran@newportbeachca.gov or by uploading directly to City Virtual Connect (CiViC) portal. April 12, 2023 PA2023-0051 Page 3 Tmplt. 10/23/2018 For your information: The project proposed to demolish an existing triplex and build a duplex and ADU. Although an ADU is allowed by SB330 to qualify as a replacement unit, Coastal Commission has appealed projects in the past for ADUs/JADUs not being equivalent or substantial in size. Please provide the existing (or approximate) square footage of each unit separately in order to prevent delays with the Coastal Commission. Upon verification of completion, the application will be processed and scheduled for a Zoning Administrator Hearing. Should you have any questions regarding submittal requirements, please contact Jenny Tran, Assistant Planner, at 949-644-3212 or jtran@newportbeachca.gov. By: ____________________________ Jenny Tran, Assistant Planner Attachments: Plan Check Corrections Redline Plans Public Works Corrections Building and Geotechnical Review c: Edwin Haronian 3347 Clerendon Road Beverly Hills, CA 90210 Stephen Wan 9 Jenner, Suite 290 Irvine, CA 92618 City of Newport Beach Community Development Department 100 Civic Center Drive / P.O. Box 1768 Newport Beach, CA 92658 Phone: (949) 644-3200 www.newportbeachca.gov PLANNING DIVISION PLAN CHECK CORRECTIONS F:\Users\CDD\Shared\Admin\Planning_Division\Current_Templates Revised 09-11-18 – CDD Plan Checker Jenny Tran Phone No: 949.644.3212 Email Address: jtran@newportbeachca.gov: PLAN CHECK NO. PA2023-0051 ADDRESS: 413 VIA LIDO SOUD CORRECTION DATE: 4/12/2023 CORRECTIONS: Setbacks: F: 4’ (Via Lido Soud), F: 0’ (Boardwalk), S: 3’ 1. The open volume/space calculation on Sheet GN1.3 appears to have an incorrect square footage (see markup on attached plans). Correct the square footage and calculation. 2. Provide the interior clear dimension of the garage on Sheet A2.1. 3. The kitchen in the ADU must have a full stove and cannot be a hot plate only. Clarify if the kitchen has a stove. 4. Show the 4’ utility easement along the front property line along Via Lido Soud. Please submit written responses to this corrections list and redlined plans at the time of resubmittal. 3'-0" SIDE SETBACK 3'-0" SIDE SETBACK 4'- 0 " FR O N T SE T B A C K N1 7 ° 2 9 ' 0 0 " E 9 0 . 0 0 ' N72°31'00"W 40.02' N72°31'00"W 40.02' N1 7 ° 2 9 ' 0 0 " E 9 0 . 0 0 ' boardwalk existing boat yard existing triplex dn up 1331.6 sf 226.1 sf 118.5 sf 374.3 sf 429.2 sf <182.7 sf> <21.7 sf> 3'-0" SIDE SETBACK 3'-0" SIDE SETBACK 4'- 0 " FR O N T SE T B A C K N1 7 ° 2 9 ' 0 0 " E 9 0 . 0 0 ' N72°31'00"W 40.02' N72°31'00"W 40.02' N1 7 ° 2 9 ' 0 0 " E 9 0 . 0 0 ' boardwalk existing boat yard existing triplex up dn 1956.1 sf 133.1 sf <179.2 sf> <293.6 sf> (70.3 sf) <54.0 sf> 3'-0" SIDE SETBACK 3'-0" SIDE SETBACK 4'- 0 " FR O N T SE T B A C K N1 7 ° 2 9 ' 0 0 " E 9 0 . 0 0 ' N72°31'00"W 40.02' N72°31'00"W 40.02' N1 7 ° 2 9 ' 0 0 " E 9 0 . 0 0 ' boardwalk existing boat yard existing triplex dn 498.7 sf 77.4 sf a/c well DESCRIPTIONISSUE DATE pr o g r e s s s e t 1- 1 9 - 2 2 10/20/17 4 7 0 w a l d ir v i n e , c a 9 2 6 1 8 (9 4 9 ) 4 5 0 . 0 0 9 3 in f o @ o l s o n a r c h i t e c t . c o m JOB NO. IN-HOUSE XX/XX/XX 2203 PLAN CHECK :- - - PLOT DATE 2/17/23 41 3 v i a l i d o s o u d 1 LANDLORD SUB 1 41 3 v i a l i d o s o u d ne w p o r t b e a c h , c a 9 2 6 6 3 ne w t r i p l e x ALL DRAWINGS, DESIGNS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF DAVID R OLSON ARCHITECTS AND THE SAME SHALL NOT BE DUPLICATED, USED, OR ASSIGNED TO ANY THIRD PARTY WITHOUT THE WRITTEN CONSENT OF DAVID R. OLSON ARCHITECTS. 10/27/17CITY SUB 1 11/20/17CITY SUB 2 2 12/06/17CITY SUB 3 2/17/23COASTAL DEVELOPMENT 1 GN1.3 area calculations first floor / garage area calculation 3/16"=1'-0"A area calculations second floor area calculation Broof deck area calculation C 3/16"=1'-0"3/16"=1'-0" MAXIMUM LOT COVERAGE MAXIMUM GROSS SQ. FTG. F.A.R. PROPOSED 5,117 SF ALLOWED FLOOR AREA TOTAL FLOOR AREA CALCULATION BUILDABLE AREA LOT SIZE 3,601.8 SF DECK AREA CALCULATIONS REQUIREDOFF-STREET PARKING GROSS DWELLING FLOOR AREA REQUIRED NUMBER OF TOTAL PARKING SPACES NUMBER OF GARAGE SPACES 2ND FLOOR COVERED DECK ROOF DECK (UNCOVERED) TOTAL DECK AREA 1956.1 SF PROPOSED 940 SF PROPOSED 2,924 SF 1.75 N/A PROPOSED TOTAL 2,449.4 SF 498.7 SF ADU 2,449.4 SF GARAGE 2 PER UNIT 2 PER UNIT 17'-6"X19' 2 2 20'-0"X20'-0" 118.5 SF N/A 363.9 SF OPEN SPACE CALC 15% OF BUILDABLE AREA GROSS DWELLING FLOOR AREA AREA REQUIRED 438.75 SF BUILDABLE AREA 2,925 SF AREA PROPOSED 884.5 SF 175.0 SF 293.6 SF 182.7 SF 179.2 SF 54.0 SF PROPOSED UNIT A UNIT B 1,990.3 SF 10'-0"X35'-0" 2 2 4,439.7 S.F. PROPOSED UNIT A UNIT B FIRST FLOOR SECOND FLOOR 226.1 SF 1335.0 SF 429.2 SF 374.8 SF 1,990.3 SF 2,449.4 SF1,990.3 SF 70.3 SF 293.6 SF EXTERIOR STAIR (UNCOVERED)77.4 SF 3'-0" SIDE SETBACK 3'-0" SIDE SETBACK 4' - 0 " FR O N T SE T B A C K N1 7 ° 2 9 ' 0 0 " E 9 0 . 0 0 ' N72°31'00"W 40.02' N72°31'00"W 40.02' N1 7 ° 2 9 ' 0 0 " E 9 0 . 0 0 ' boardwalk existing boat yard existing triplex w/d uc ref ice garage a garage b wh adu/bed 2a laundry a bar living akitchen a great room hall a covered deck ref/frz dw dn uc ref bath 2a master bed a master bath a dssr wh foyer b bed 1a pantry elev up bath 1a powder micro bbq ct dssr b a4.1 f a4.2 e a4.2 a a4.1 c a4.1 d a4.2 3' - 5 12" 33 ' - 4 12" 9'- 6 " 37 ' - 1 12" 2'-6"26'-1112"2'-6" 32'-0" 1' - 8 " 4'- 7 12" 4' - 8 " 5' - 0 " 7'- 6 " 1'- 6 " 26 ' - 4 " 1' - 1 1 12" 1' - 1 1 12" 6'- 1 0 " 19 ' - 3 12" 1'-1112" 8'-0" 1'-1112" 17'-0" 1'-1112" 30'-1012" 2'-112" 3'- 1 0 " 14 ' - 7 " 13 ' - 1 1 12" 10 ' - 1 1 12" 1'-0" 1'-0" 1'-0" 1' - 8 " 3'-0" SIDE SETBACK 3'-0" SIDE SETBACK 4'- 0 " FR O N T SE T B A C K N1 7 ° 2 9 ' 0 0 " E 9 0 . 0 0 ' N72°31'00"W 40.02' N72°31'00"W 40.02' N1 7 ° 2 9 ' 0 0 " E 9 0 . 0 0 ' boardwalk existing boat yard existing triplex ref/ frz pantry kitchen b dw bbq bar up open master bed b bed 3b bed 2b living bdining b covered outdoor room hall b ext. stairs b balcony uc wine uc ref roof below li n e n powder fp / t v a b v ba 2b linen ba 3b ju l i e t t e b a l c o n y master closet b master bath b fp / tv abv coats elev den / bed 1b ba 1b stacked dn micro b a4.1 f a4.2 e a4.2 a a4.1 c a4.1 d a4.2 8'- 5 " 40 ' - 8 " 3' - 9 12" 5' - 3 12" 3' - 3 12" 1' - 0 " 5'-1112" 3'-8" 3'-0"3'-5"9'-0"3'-5"3'-412" 3' - 3 12" 15 ' - 5 " 14 ' - 7 " 16 ' - 3 " 1' - 4 " 7'- 3 12" 5' - 4 " 6' - 0 " 5'- 6 " 9' - 7 " 32'-0" 16 ' - 9 12" 17 ' - 7 " 12 ' - 1 12" 3'-0"1'-0" 4'-0" 2'-112" 1'-0" 1' - 4 " 19 ' - 9 12" 12 ' - 4 12" DESCRIPTIONISSUE DATE pr o g r e s s s e t 1- 1 9 - 2 2 10/20/17 4 7 0 w a l d ir v i n e , c a 9 2 6 1 8 (9 4 9 ) 4 5 0 . 0 0 9 3 in f o @ o l s o n a r c h i t e c t . c o m JOB NO. IN-HOUSE XX/XX/XX 2203 PLAN CHECK :- - - PLOT DATE 2/17/23 41 3 v i a l i d o s o u d 1 LANDLORD SUB 1 41 3 v i a l i d o s o u d ne w p o r t b e a c h , c a 9 2 6 6 3 ne w t r i p l e x ALL DRAWINGS, DESIGNS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF DAVID R OLSON ARCHITECTS AND THE SAME SHALL NOT BE DUPLICATED, USED, OR ASSIGNED TO ANY THIRD PARTY WITHOUT THE WRITTEN CONSENT OF DAVID R. OLSON ARCHITECTS. 10/27/17CITY SUB 1 11/20/17CITY SUB 2 2 12/06/17CITY SUB 3 2/17/23COASTAL DEVELOPMENT 1 A2.1 first & second floor construction plans first floor / garage plan 1/4"=1'-0"A 2X4 WOOD STUD WALL WITH STUDS AT 16" O.C.; PROVIDE 3 1/2" UNFACED BATT INSULATION AT INTERIOR WALLS; USE 3X4 WHERE REQUIRED BY STRUCTURAL DRAWINGS; CARRY FULL HEIGHT AT BEDROOM/BATHROOM/ MECH. RM. WALLS WITH ONE LAYER OF 5/8" TYPE "X" AND BATT INSUALTION FOR SOUND ATTENUATION. USE SLIP JOINT AT NON-BEARING CONDITIONS PER STRUCTURAL; USE 2X6 OR 2X8 WHERE INDICATED ON PLAN OR REQUIRED BY STRUCTURAL. 2X6 WOOD STUD WALL AT ALL PLUMBING WALLS U.N.O. AND WHERE INDICATED ON PLAN; 16" O.C.; BATT INSULATION TO BE R21 AT EXTERIOR WALLS OR PER T24, WHICHEVER IS GREATER; PROVIDE 3 1/2" UNFACED BATT INSULATION AT INTERIOR WALLS FOR SOUND ATTENUATION; CARRY FULL HEIGHT AT BEDROOM/BATHROOM/MECH. RM. WALLS WITH ONE LAYER OF 5/8" TYPE "X" AND BATT INSULATION FOR SOUND ATTENUATION; USE SLIP JOINT AT NON-BEARING CONDITIONS. VENEER WHERE OCCURS wall legend plan keynotes 4 5/8" TYPE "X" GYPSUM BOARD FOR 1 HOUR CONSTRUCTION PER CBC 406.1.4 ON ALL WALLS AND CEILINGS ADJACENT TO LIVING SPACE AND ALL WALLS SUPPORTING THE HORIZONTAL PORTION OF THE OCCUPANCY SEPARATION WHERE OCCURS. FIRE & SOUND RATED WALL PER LEGEND 1 2 5 CLOSET SHELF AND POLE AS SELECTED 6 11 3 12 13 8 COOKTOP/RANGE EXHAUST. PROVIDE UTILITIES AS REQUIRED. INSTALL PER MANUFACTURER'S INSTRUCTIONS. A) HOOD AS SELECTED BY OWNER; PROVIDE MINIMUM 100 CFM; VENT TO OUTSIDE B) DOWNDRAFT; INSTALL PER MANUFACTURER'S INSTRUCTIONS 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 SINGLE SINK WITH GARBAGE DISPOSAL. PROVIDE POWER TO DISPOSAL AS REQUIRED. SINK FAUCET TO HAVE MAXIMUM FLOW RATE OF 1.5GPM AT 60 P.S.I; PROVIDE POWER TO DISPOSAL AS REQUIRED REFRIGERATOR/FREEZER AS SELECTED. PROVIDE POWER AND COLD WATER SUPPLY AS REQUIRED. INSTALL OUTLET AT HEIGHT AS RECOMMENDED BY MANUFACTURER TUB AS SELECTED DISHWASHER AS SELECTED; PROVIDE UTILITIES AS REQUIRED VERIFY PULLMAN/COUNTER WITH OWNER. WALL MOUNTED LAVATORIES AND TOILETS ARE NOT PERMITTED IN SOUND-RATED PARTITIONS MINIMUM CLEARANCE REQUIREMENTS FOR WATER CLOSETS TO BE 30" WIDE AND MINIMUM CLEARANCE IN FRONT OF WATER CLOSET TO BE 24". WATER CLOSETS TO BE LOW FLUSH TOILETS PER HSC 17921.3(b). WALL MOUNTED LAVATORIES AND TOILETS ARE NOT PERMITTED IN SOUND-RATED PARTITIONS. SOAP/SHAMPOO NICHE; A) 12" W X 16" H SHAMPOO NICHE WITH SHELF AT 4" FROM TOP; SET BOTTOM OF SOAP NICHE AT 36"± ABOVE SHOWER FLOOR. SLOPE BOTTOM OF EACH NICHE SLIGHTLY FOR DRAINAGE. B)12"X12" SHAMPOO NICHE (VERIFY DIMENSIONS W/OWNER); SET BOTTOM OF SHAMPOO NICHE AT 36"± ABOVE TUB DECK (MAINTAIN 12" MODULE) AND SET SOAP NICHE AT 12" ABOVE TUB DECK. SLOPE BOTTOM OF EACH NICHE SLIGHTLY FOR DRAINAGE. 14"X6" SCREENED VENT LOW VENT FOR COMBUSTION AIR VENT WITHIN 12'' OF FLOOR HIGH VENT FOR COMBUSTION AIR VENT WITHIN 12" OF CEILING 18" HIGH X 3/4" PAINTED EXTERIOR PLYWOOD PLATFORM MAINTAIN 2" CLEARANCE TO COMBUSTIBLE MATERIALS PER LISTING. PROVIDE METAL STUD SPACERS WHERE REQUIRED DECK DRAIN ROUTED TO CIVIL SYSTEM SLOPE DECK TO DRAIN FOR POSITIVE DRAINAGE; PROVIDE ADJACENT THROUGH WALL OVERFLOW AT 2" ABOVE FINISH SURFACE. SEE 15/D1.3 42'' HIGH GUARDRAIL LINEN CLOSET, STORAGE CABINET, DESK, PANTRY OR BUFFET AS SELECTED PROVIDE TILE OR STONE MINIMUM 70" ABOVE DRAIN AT ALL SHOWERS; MORTAR SET OVER MEMBRANE; HOT MOPPED SHOWER PANS SHALL BE INSPECTED UPON COMPLETION OF HOT MOPPING AND SHALL BE FILLED WITH WATER FOR INSPECTION. NET AREA TO BE MINIMUM 1024 IN2. I. W/ MIN. 30" DIA. CIRCLE. LAUNDRY SINK AS SELECTED 7 PROVIDE RECESSED IRON ANGLE SUPPORTS AT BAR/COUNTERS 9 10 STACKABLE WASHER AND DRYER AS SELECTED; PROVIDE UTILITIES AS REQUIRED. PROVIDE SMOOTH, METAL DRYER VENT TO OUTSIDE PER CODE AND LOCAL AGENCY REQUIREMENTS. USE 5" ROUND DUCTS WITH (2) 90 DEGREE BENDS; DRYER DUCT SHALL HAVE A BACKDRAFT DAMPER PER CMC 504.1; VENT THROUGH ROOF; MAXIMUM 14' FIREPLACE FINISHES AS SELECTED 14 15 TEMPERED/SAFETY GLASS ENCLOSURE AT TUB OR SHOWER. SHOWERS TO BE RECESSED 42" HIGH TEMPERED GLASS GUARDRAIL DASHED LINE INDICATES EDGE OF CEILING OR PROJECTION OR WALL ABOVE MECHANICAL UNIT PER T-24. MAINTAIN A MINIMUM 30" DEEP UNOBSTRUCTED WORKING SPACE IN FRONT OF FURNACE PER CMC SECTION 904.11.4. FAU CLOSET MUST BE 12" WIDER THAN THE FURNACE(S) BEING INSTALLED. UNDER COUNTER ICE REF; PROVIDE UTILITIES AS REQUIRED 50' MAXIMUM PATH OF TRAVEL TO EXIT STAIR PER R311.440 BAR SINK AS SELECTED, WITH GARBAGE DISPOSAL41 42 PROVIDE CLASS A WATERPROOF ROOF DECK BY DEX-O-TEX WEATHERWEAR OR NOBLE OR BETTER, SLOPE MIN. 2% TO DECK DRAIN. ICC-ES ESR-1757 LANDINGS SHALL NOT BE MORE THAN 1-1/2" LOWER THAN TOP OF THRESHOLD WHERE THE DOOR SWINGS OVER THE THRESHOLD. LANDINGS ON THE EXTERIOR SIDE SHALL NOT BE MORE THAN 7-3/4" INCHES BELOW THE TOP OF THRESHOLD PROVIDED THE DOOR DOES NOT SWING OVER THE LANDING OR FLOOR (R311.3.1). PROVIDE STAINLESS STEEL FLASHING SHEET AT FACE OF FOOTING AT TRANSITION TO DOOR THRESHOLD LANDING LENGTH TO BE A MINIMUM OF 36" IN THE DIRECTION OF TRAVEL. 43 RECESSED MEDICINE CHEST AS SELECTED; VERIFY LOCATIONS UNDER COUNTER REFRIGERATOR, PROVIDE UTILITIES AS REQUIRED A) DIRECT VENT GAS FIREPLACE WITH GLASS FRONT; MONTIGO H42DF OR EQUAL. DRAWINGS FOR SPECIFICATIONS AS SELECTED. INSTALL PER MANUFACTURER'S SPECS, PROVIDE COVER GLASS AT MASTER BEDROOM; ROUTE VENT THROUGH FLOOR JOISTS THROUGH EXTERIOR SIDEWALL B) DIRECT VENT GAS FIREPLACE WITH GLASS FRONT; MONTIGO P52DF OR EQUAL. DRAWINGS FOR SPECIFICATIONS AS SELECTED. INSTALL PER MANUFACTURER'S SPECS, PROVIDE COVER GLASS AT MASTER BEDROOM; ROUTE VENT THROUGH FLOOR JOISTS THROUGH EXTERIOR SIDEWALL 44 SILL AT 42" A.F.F 45 ALL ACCESSORY STRUCTURES ON ROOF DECK (COUNTERS, BBQ SPA, ETC.) TO COMPLY WITH FLAT HEIGHT LIMITATION (24') ELEVATOR CONTROL PANEL. PROVIDE 30X36 WORKING CLEARANCE 1HR FIRE RATED WALL. 2X4 WOOD STUD WALL WITH STUDS AT 16" O.C.; 1 LAYER 5/8" W.R. TYPE "X' GYP. BD. O/ 1/2" PLYWOOD PLYWOOD SHEATHING WHERE OCCURS PER STRUCTURAL DRAWING ON EXTERIOR. R19 BATT INSULATION. 5/8" TYPE "X" W.R. GYPSUM BOARD ON THE INTERIOR. SEE DETAIL 20/D1.2 46 NOT USED. HATCHED AREA INDICATES 1HR & SOUND RATED FLOOR ASSEMBLY ABOVE PER DETAIL 18/D1.2 IRON AWAY E-342 FOLD-DOWN IRONING BOARD OR EQUAL; PROVIDE UTITLIES AS REQUIRED UNDER COUNTER WINE COOLER; PROVIDE UTILITIES AS REQUIRED AS SELECTED. PROVIDE POWER AND COLD WATER SUPPLY AS REQUIRED. INSTALL OUTLET AT HEIGHT AS RECOMMENDED BY MANUFACTURER 2x6 PLUMBING WALL PER WALL LEGEND RESIDENTIAL ELEVATOR PER SPECIFICATIONS 47 DASHED LINE INDICATES ADHERED STONE VENEER 48 DECORATIVE WOOD TRELLIS; PAINT TO MATCH WOOD SIDING FLOOR DRAIN ROUTED DOWN THROUGH WALL TO CIVIL SYSTEM 2X4 WOOD STUD LOW WALL WITH STUDS AT 16" O.C. 1HR FIRE AND SOUND RATED WALL. 2X WOOD STUD WALL WITH STUDS AT 16" O.C.; 1 LAYER 1/4" GYP. BD. BASE LAYER EACH SIDE WITH 1 LAYER 5/8" TYPE "X' GYP. BD. TOP LAYER EACH SIDE. SEE DETAIL 19/D1.2 NOT USED. second floor plan 1/4"=1'-0"B 3 13 15 10 12 11 21 38 22 19 7 1A 6 3725 83041 42 22 23 42 4219 22 38 25 2420 23 24 22 19 25 543 9 28 26 21 16 18 42 5 5 38 2 8 19 22 3 37 27 37 27 27 28 26 9 25 5 2423 20 5 27 27 SLOPE SLO P E 3 35 15 10 12 11 13 35 83141 1B 6 21 21 2522 19 34 43 423822 16 18 19 22 23 7 1A 6 21 25 3 42 38 38 3 19 22 24 23 25 22 20 2423 2024 23 42 14 19 22 38 25 34 34 19 F F A B C D E G G H G G J J L K K L L L C Q MMN 101 102 103 104105 106 107 108 109 110 111 112 113 113 114 115116 117 118 119 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 120 Tmplt: 06/07/19 P ROJECT R EVIEW R EQUES T C O M M U N I T Y D E V E L O P M E N T D E P A R T M E N T Planning Division Please Distribute to: Building – Tonee Thai Public Works – David Keely Fire – James Gillespie Geotechnical Engineer – Sergio Gutierrez Date: March 16, 2023 Please return PRR and Plans to Staff Planner Jenny Tran, Assistant Planner 949-644-3212, jtran@newportbeachca.gov Applicant: David R. Olson Architects Contact: Stephen Wan 949-450-0093 Steve@OlsonArchitect.com Project Name Horonian Residence Address: 413 Via Lido Soud PA2023-0051 Coastal Development Permit A coastal development permit to demolish an existing triplex and construct a new 3-story duplex and 1 ADU on Lido Isle. REPORT REQUESTED BY: March 30, 2023 Zoning Administrator Hearing: Hearing Date: TBD Check all that apply: ❑ No comments on the project as presented. Notes: 1. 2022 California Building Codes will apply to this project, not the 2022 California Residential Code. 2. This site is in a Soils Liquefaction Seismic Hazard Area. This information will need to be added to the building data on the cover sheet. The soils report will be required to comply with Newport Beach Building Code Policy CBC 1803.5.11-12. 3. An NFPA 13R fire sprinkler system is required (CBC 903.3.1.2, 1006.2). Fire sprinkler protection for the roof deck and covered decks on the 1st and 2nd floors is required (CBC 903.3.1.2.1). 4. A single exit is permitted for the dwelling unit occupying the second floor and roof deck if the exit access travel distance complies with CBC Table 1006.3.4(1) or if the stairway from the 2nd to the 1st floor is constructed as in interior exit stairway according to CBC 1027 (CBC 1006.3.4 Part 1 or 5). 5. The BBQs on the covered decks are required to be listed for use beneath combustible construction. If hoods are X Application of Standard Code requirements are not expected to alter the project design. ❑ Recommended conditions of approval are attached. ❑ Application of Standard Code requirements or the attached conditions of approval will substantially impact or alter the design of the project. ❑ I contacted the applicant on ❑ To schedule an appt. for Code review ❑ To discuss the following (see notes) Tmplt: 06/07/19 provided as a means of protection for the combustible construction, the hood is required to be listed with the BBQ. 6. Doors in 1-hr fire rated partitions separating dwelling units shall be fire rated according to CBC Table 716.1(2) and hardware shall comply with CBC 716.2.6. This requirement also applies where there are exterior spaces between dwelling units and walls are separated by less than 6’. See for example the exterior space between Garage ‘a’ and ADU/Bed 2a. 7. Floor separating dwelling units is required to be 1-hr fire resistance rated (CBC 420.3, 711.2.4.3). The stairway between the 1st and 2nd floor shall be fire rated as a floor assembly where it separates upper and lower dwellings. 8. Walls and floor separating dwelling units are required to be sound rated according to requirements in CBC 1206. 9. Openings in exterior walls parallel to property lines are required to comply with the requirements for limitation of openings in CBC 705.8. Openings include those below the floor and roof framing where the covered 1st and 2nd floor deck areas occur. Signature Ext. Date Tmplt: 06/07/19 P ROJECT R EVIEW R EQUES T C O M M U N I T Y D E V E L O P M E N T D E P A R T M E N T Planning Division Please Distribute to: Engineer Geologist – Sergio Gutierrez Date: March 16, 2023 Please return PRR and Plans to Staff Planner Jenny Tran, Assistant Planner 949-644-3212, jtran@newportbeachca.gov Applicant: David R. Olson Architects Contact: Stephen Wan 949-450-0093 Steve@OlsonArchitect.com Project Name Horonian Residence Address: 413 Via Lido Soud PA2023-0051 Coastal Development Permit A coastal development permit to demolish an existing triplex and construct a new 3-story duplex and 1 ADU on Lido Isle. REPORT REQUESTED BY: March 30, 2023 Zoning Administrator Hearing: Hearing Date: TBD Check all that apply: ❑ No comments on the project as presented. Notes: Based on Preliminary review of proposed Grading Plan by AQX finish grade elevation and Preliminary WQMP the project is deemed satisfactory for CDP permit, pending formal review during building review. Sergio Gutierrez 3213 23/22/2023 Signature Ext. Date X Application of Standard Code requirements are not expected to alter the project design. ❑ Recommended conditions of approval are attached. ❑ Application of Standard Code requirements or the attached conditions of approval will substantially impact or alter the design of the project. ❑ I contacted the applicant on ❑ To schedule an appt. for Code review ❑ To discuss the following (see notes)