Contractor's Material and Test Certificate for Aboveground Piping
PROCEDURE
Upon completion of work, inspection and tests shall be made by the Contractor's representative and witnessed by an owner's representative. All defects
shall be corrected and system left in service before contractor's personnel finally leave the job.
A certificate shall be filled out and signed by both representatives. Copies shall be prepared for approving authorities, owners, and contractor. It is
understood the owner's representative's signature in no way prejudices any claim against contractor for faulty material, poor workmanship, or failure to
comply with approving authority's requirements or local ordinances.
PROPERTY ADDRESS 880 IRVINE AVE ADU CONVERSION
ACCEPTED BY APPROVING AUTHORITIES (NAMES) NEWPORT BEACH FIRE DEPT.
ADDRESS
PLANS
INSTALLATION CONFORMS TO ACCEPTED PLANS
EQUIPMENT USED IS APPROVED
IF NO, EXPLAIN DEVIATIONS
® YES
® YES
❑ NO
❑ NO
HAS PERSON IN CHARGE OF FIRE EQUIPMENT BEEN INSTRUCTED AS TO LOCATION ® YES
OF CONTROL VALVES AND CARE AND MAINTENANCE OF THEIS NEW EQUIPMENT?
IF NO, EXPLAIN
❑ NO
INSTRUCTIONS
HAVE COPIES OF THE FOLLOWING BEEN LEFT ON THE PREMISES
1. SYSTEM COMPONENTS INSTRUCTIONS
2. CARE AND MAINTENANCE INSTRUCTIONS
3. NFPA 25
® YES
® YES
® YES
® YES
❑ NO
❑ NO
❑ NO
❑ NO
MAKE
MODEL
YEAR OF
MANUFACTURE
ORIFICE
SIZE
QUANTITY
TEMPERATURE
RATING
SPRINKLERS
VICTAULIC FL- R
V2704
2022
112
40
200
VICTAULIC FL -OR
V2708
2022
112
93
200
VICTAULIC FL-RES/C
V4906
2022
112
80
155
PIPE AND
FITTINGS
TYPE OF PIPE DYNA THREAD I BLAZEMASTER
TYPE OF FITTINGS CAST
ALARM VALVE
ALARM DEVICE
MAXIMUM TIME TO OPERATE
THROUGH TEST CONNECTION
OR
TYPE
MAKE
I MODEL
MIN
SEC
FLOW
NIA
1 NIA
N/A
N/A
NIA
INDICATOR
MAKE
MODEL I SERIAL NO.
MAKE
MODEL
SERIAL NO.
IA
NIA I NIA
NIA
NIA
NIA
DRY PIPE
OPERATING
TIME TO TRIP
THROUGH TEST
CONNECTION
WATER
PRESSURE
AIR rRIP
PRESSURE
POINT
AIR PRESSURE
TIME WATER
REACHED
TEST OUTLET
ALARM
OPERATED
PROPERLY
TEST
MIN
SEC
PSI
PSI
PSI
MIN
I SEC
YES
NO
WITH
O.O.D.
W/O
Q.O.D.
IF NO, EXPLAIN
OPERATION rl PNEUMATIC f1 ELECTRIC rl HYDRAULIC
PIPING SUPERVISED rl YES n NO DETECTING MEDIA SUPERVISED 11 YES
rl NO
DELUGE &
DOES THE VALVE OPERATE FROM THE MANUAL TRIP AND/OR REMOTE
CONTROL STATIONS
rl YES
rl NO
PREACTION
VALVES
IS THERE AN ACCESSIBLE FACILITY IN EACH CIRCUIT IF NO, EXPLAIN MIA
FOR TESTING? El YES r 1 NO
MAKE
MODE
DOES EACH CIRCUIT OPERATE
SUPERVISIONLOSS ALARM
DOES EACH CIRCUIT
OPERATE ALVE RELEASE
MAXIMUM TIME TO
OPE TE RELEASE
N/A
N/A
YE
NO
I YES
NO
MIN
SEC
PRESSURE
I LOCATION MAKE & SETTING STATIC
PRESSURE RFSIDIIAI PRFSSIIRF
FI OW RATE
REDUCING
VALVETEST
HYDROSTATIC: Hydrostatic tests shall be made at not less than 200 psi (13.6 bars) for two hours or 50 psi (3.4 bars) above static
TEST
pressure in excess of 150 psi (10.2 bars) for two hours. Differential dry -pipe valve clappers shall be left open during test to prevent
DESCRIPTION
damage. All aboveground piping leakage shall be stopped.
PNEUMATIC Establish 40 psi (2.7 bars) air pressure and measure drop, which shall not exceed I'' psi (0.1 bars) in 24 hours. Test
r)ressure tanks at n rmal water level and air pressure and measure air Pressure droo which shall not exceed 1'h psi in 24 hours.
ALL PIPING HYDROSTATICALLY TESTED AT 200 FOR 2 HOURS IF NO, STATE REASON NO, NOT REQUIRED
DRY PIPING PNEUMATICALLY TESTED ❑ YES ® NO
EQUIPMENT OPERATES PROPERLY 0 YES I —I NO
DO YOU CERTIFY AS THE SPRINKLER CONTRACTOR THAT ADDITIVES AND CORROSIVE CHEMICALS, SODIUM SILICATE
OR DERIVATIVES OF SODIUM SILICATE, BRINE, OR OTHER CORROSIVE CHEMICALS WERE NOT USED FOR TESTING
SYSTEMS OR STOPPING LEAKS? M YES Fl NO
DRAIN READING OF GAGE LOCATED NEAR WATER RESIDUAL PRESSURE WITH VALVE IN TEST
TESTS
TEST_ SUPPLY TEST CONNECTION PSI CONNECTION OPEN WIDE PSI
UNDERGROUND MAINS AND LEAD-IN CONNECTIONS TO SYSTEM RISERS FLUSHED BEFORE
CONNECTION MADE TO SPRINKLER PIPING.
VERIFIED BY COPY OF THE U FORM NO. 858 ❑ YES []NO OTHER EXPLAIN
FLUSHED BY INSTALLER OF UNDERGROUND NIA
SPRINKER PIPING Fl YES FIND
IF POWDER DRIVEN FASTENERS ARE USED IN CONCRETE IF NO, EXPLAIN
HAS REPRESENTATIVE SAMPLE TESTING BEEN COMPLETED? FJYES NO NIA
BLANK TEST
NUMBER USED LOCATIONS NUMBER REMOVED
GASKETS
NIA NIA NIA
WELDED PIPING El YES M NO
IF YES
DO YOU CERTIFY AS THE SPRINKLER CONTRACTOR THAT WELDING PROCEDURES COMPLY
WITH THE REQUIREMENTS OF AT LEAST AWS D10.9. LEVEL AR 3? ❑ YES ® NO
DO YOU CERTIFY THAT THE WELDING WAS PERFORMED BY WELDERS QUALIFIED IN COMPLIANCE
WELDING
WITH THE REQUIREMENTS OF AT LEAST AWS D70.9. LEVEL AR 3? ❑ YES ® NO
DO YOU CERTIFY THAT WELDING WAS CARRIED OUT IN COMPLIANCE WITH A DOCUMENTED
QUALITY CONTROL PROCEDURE TO INSURE THAT ALL DISCS ARE RETRIEVED, THAT OPENINGS
IN PIPING ARE SMOOTH, THAT SLAG AND OTHER WELDING RESIDUE ARE REMOVED, AND THAT
THE INTERNAL DIAMETER PIPING ARE NOT PENETRATED) 0 YES M NO
CUTOUTS
DO YOU CERTIFY THAT YOU HAVE A CONTROL FEATURE TO ENSURE THAT ALL CUTOUTS (DISCS)
DISCS
ARE RETRIEVED? YES R NO
HYDRAULIC
NAMEPLATE PROVIDED IF NO, EXPLAIN
DATA
® YES ❑ NO
NAMEPLATE
DATE LEFT IN SERVICE WITH ALL CONTROL VALVES OPEN.
REMARKS
7-20.202
NAME OF SPRINKER CONTRACTOR:
APEX FIRE SYSTEMS INC.
SIGNATURES
TESTS WITNESSED BY
•
FOR PROPERTY 0 NER (SIGNF.C11 TITLE DATE
n' .
FOR SPRINK hM R.K�.Tnr�tS M TITI P nnTF
EXPLANATIONS AND