Loading...
HomeMy WebLinkAboutPA2022-0314_20221221_Plan Submittal 42x30LOT AREA: MAX. TOTAL FLOOR AREA CITYWIDE (BUILDABLE x2): CITY OF NEWPORT BEACH BUILDABLE AREA: CONDITIONED FLOOR AREA TOTAL CONDITIONED FLOOR AREA: UNCONDITIONED AREA GARAGE: COVERED PATIO: REQUIRED OPEN VOLUME AREA (BUILDABLE X15%): PROVIDED OPEN VOLUME AREA: SECOND FLOOR CONDITIONED: SECOND FLOOR BALCONY: 5600 SQ. FT. 4046 SQ. FT. 8092 SQ. FT. 888 SQ. FT. 190 SQ. FT. 606.90 SQ. FT. 3487 SQ. FT. 551 SQ. FT. 658 SQ. FT. PROPOSED FLOOR AREA GARAGE:658 SQ. FT. TOTAL FLOOR AREA:1209 SQ. FT. SECOND FLOOR COVERED DECK:73 SQ. FT. 551 SQ. FT. EXTERIOR STAIRS 76 SQ. FT. SECOND FLOOR CONDITIONED:551 SQ. FT. EXISTING DOCK TO BE REPAIRED 462 SQ. FT. TITLE SHEET A0.0 944 VIA LIDO NORD 944 VIA LIDO NORD NEWPORT BEACH, CALIFORNIA 92663 DRAWING INDEX: ABBREVIATIONS SCOPE OF WORK DESCRIPTION: PROJECT DIRECTORY: OWNER:THE 944 VIA LIDO NORD TRUST PROJECT ADDRESS:944 VIA LIDO NORD NEWPORT BEACH, CA 92663 ZONE:R-1 FLOOD ZONE: AE/X LEGAL DESCRIPTION: LOT # :324 TRACT # :907 APN # :423-281-10 LOT AREA :5,600 SQ. FT. OCCUPANCY:R-3 TYPE OF CONSTRUCTION:TYPE V-B SPRINKLERED (NFPA 13D) ALL ROOFS TO BE CLASS "A" PER ESR-3267, ESR 1647 AND/OR UES ER_0412 NO. STORIES:2 NO. UNITS: 1 PROJECT DATA: DEFERRED SUBMITTALS: SQUARE FOOTAGE TABULATIONS VICINITY MAP: THE 944 VIA LIDO NORD TRUST 944 VIA LIDO NORD NEWPORT BEACH CA. 92663 1.AN OPERATION AND MAINTENANCE MANUAL TO THE BUILDING SHALL BE AVAILABLE AT THE TIME OF FINAL INSPECTION AND PROVIDED TO THE OWNER OR OCCUPANT (4.410.1) 2.ANY INSTALLED GAS FIREPLACE SHALL BE A DIRECT-VENT SEALED-COMBUSTION TYPE. ANY WOOD STOVES OR PELLET STOVES SHALL COMPLY WITH US EPA NEW SOURCE PERFORMANCE STANDARDS (NSPS) EMISSION LIMITS WHERE APPLICABLE (4.503.1) 3.DUCT OPENINGS AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED DURING CONSTRUCTION (4.504.1) 4.WHERE RESILIENT FLOORING IS INSTALLED, AT LEAST 80% OF FLOOR AREA SHALL COMPLY WITH ONE OR MORE OF THE FOLLOWING (4.504.4): a.CHPS LOW-EMITTING MATERIAL IN THE COLLABORATIVE FOR HIGH PERFORMANCE SCHOOLS (CHPS) HIGH PERFORMANCE PRODUCTS BASE b.CERTIFIED UNDER UL GREENGUARD GOLD c.CERTIFICATION UNDER THE RESILIENT FLOOR COVERING INSTITUTE (RFCI) FLOORSCORE PROGRAM d.MEET THE CALIFORNIA DEPARTMENT OF PUBLIC HEALTH, "STANDARD METHOD FOR THE TESTING AND EVALUATION OF VOLITILE ORGANIC CHEMICAL EMISSIONS FROM INDOOR SOURCES USING ENVIRONMENTAL CHAMBERS. 5.HARDWOOD PLYWOOD, PARTICLEBOARD, AND MEDIUM DENSITY FIBER COMPOSITE WOOD PRODUCTS USED ON INTERIOR OR EXTERIOR OF THE BUILDING, SHALL MEET THE REQUIREMENTS FOR FORMALDEHYDE AS SPECIFIED IN ARB'S AIR TOXIC MEASURE FOR COMPOSITE WOOD (4.504.5) 6.MOISTURE CONTENT OF BUILDING MATERIALS USED IN WALLS AND FLOOR FRAMINGS SHALL BE CHECKED AND VERIFIED TO BE LESS THAN 19% BEFORE ENCLOSURE. (4.505.3) 7.EACH BATHROOM SHALL BE MECHANICALLY VENTILATED AND SHALL COMPLY WITH THE FOLLOWING: (4.506.1) a.FANS SHALL BE ENERGY STAR COMPLIANT AND SHALL BE DUCTED TO TERMINATE OUTSIDE THE BUILDING. b.FANS MUST BE CONTROLLED BY A HUMIDITY CONTROL. 8.USE THE FOLLOWING METHODS TO SIZE DUCT SYSTEMS AND SELECT EQUIPMENT: (4.507.2). a.ESTABLISH HEAT LOSS AND HEAT GAIN VALUES ACCORDING TO ANSI/ACCA 2 MANUAL J-2011 OR EQUIVALENT. b.SIZE DUCT SYSTEMS ACCORDING TO ANSI/ACCA 1 MANUAL D-2014 OR EQUIVALENT. c.SELECT HEATING AND COOLING EQUIPMENT ACCORDING TO ANSI/ACCA 3 MANUAL S-2014 (MANUAL S) OR EQUIVALENT. 9.HVAC SYSTEM INSTALLERS SHALL BE TRAINED AND CERTIFIED IN THE PROPER INSTALLATION OF HVAC SYSTEMS. (702.1) 10.SPECIAL INSPECTORS SHALL BE QUALIFIED AND ABLE TO DEMONSTRATE COMPETENCE IN THE DISCIPLINE THEY ARE INSPECTING. (702.2) 11.CONSTRUCTION DOCUMENTS, PLANS, SPECIFICATIONS OF BUILDER OR INSTALLER CERTIFICATION, INSPECTION REPORTS, OR OTHER METHODS ACCEPTABLE TO THE BUILDING BUREAU ARE REQUIRED TO BE SUBMITTED TO CITY INSPECTORS FOR VERIFICATION AND COMPLIANCE AT THE TIME OF FINAL INSPECTION. (703.1) 12.CONTRACTORS SHALL COMPLETE THE FOLLOWING DOCUMENTS AND PROVIDE THEM TO THE CITY INSPECTOR AT THE TIME OF FINAL INSPECTION. a.INSTALLATION CERTIFICATES FOR VOC CONTENT VERIFICATION CHECKLIST FORM GRN-02 AND FORMALDEHYDE EMISSIONS VERIFICATION CHECKLIST FORM GRN-03. b.PRODUCTION INFORMATION SHEETS AND DECLARATION STATEMENTS FOR ADHESIVE, SEALANTS, AND CAULKS; PAINTS AND COATINGS; FINISH FLOORING MATERIALS; AND COMPOSITE WOOD PRODUCTS. CALIFORNIA GREEN CODE NOTES REFER TO SHEETS GN.4/CG AND GN.6/EC/CG FOR ADDITIONAL NOTES AND FORMS BUILDING DEPT. NOTES “AS THE ARCHITECT/ENGINEER OF RECORD, I HAVE SELECTED APPROPRIATE BMPS TO EFFECTIVELY MINIMIZE THE NEGATIVE IMPACTS OF THIS PROJECT’S CONSTRUCTION ACTIVITIES ON STORM WATER QUALITY. THE PROJECT OWNER AND CONTRACTOR ARE AWARE THAT THE SELECTED BMPS MUST BE INSTALLED, MONITORED, AND MAINTAINED TO ENSURE THEIR EFFECTIVENESS.THE BMPS NOT SELECTED FOR IMPLEMENTATION ARE REDUNDANT OR DEEMED NOT APPLICABLE TO THE PROPOSED CONSTRUCTION ACTIVITIES.” _________ ____ 10/31/2022 NAME TITLE DATE I CERTIFY THAT THE PROPOSED WORK WILL NOT DESTROY OR UNREASONABLY INTERFERE WITH ANY ACCESS OR UTILITY EASEMENT BELONGING TO OTHERS AND LOCATED ON MY PROPERTY, BUT IN THE EVENT SUCH WORK DOES DESTROY OR UNREASONABLY INTERFERE WITH SUCH EASEMENT, A SUBSTITUTE EASEMENT(S) SATISFACTORY TO THE HOLDER(S) OF THE EASEMENT WILL BE PROVIDED. AGENT 02/06/2019 NAME TITLE DATE SIGNATURE PLOT DATE: SCALE: DESIGN BY: DRAWN BY: CHECKED DATE: FILE NAME: SH E E T S : REVISIONS: BILL DURANT Th e 9 4 4 V i a L i d o N o r d T r u s t 94 4 V i a L i d o N o r d Ne w p o r t B e a c h , C A 9 2 6 6 3 P 562.424.8816 F 562.424.8440 STAMP: BI L L D U R A N T De s i g n e r / B u i l d e r 22 5 9 O r a n g e A v e n u e Si g n a l H i l l , C a l i f o r n i a 9 0 7 5 5 AS NOTED Z: \ P r o j e c t F o l d e r s \ P r o j e c t s - 2 0 1 8 \ 9 4 4 V i a L i d o N o r d T r u s t \ 3 - P l o t S h e e t s \ A 0 . 0 T I T L E S H E E T . d w g A0.0 TITLE SHEET BI L L D U R A N T De s i g n e r / B u i l d e r 22 5 9 O r a n g e A v e n u e Si g n a l H i l l , C a l i f o r n i a 9 0 7 5 5 July 24, 2020 RM / KC AS NOTED Z: \ P r o j e c t F o l d e r s \ P r o j e c t s - 2 0 1 8 \ 9 4 4 V i a L i d o N o r d T r u s t \ 3 - P l o t S h e e t s \ A 0 . 0 T I T L E S H E E T . d w g A0.0 TITLE SHEET CHANGE ABV. A/C ADJ. ALT AMP. BD. CAB. CLG. CLR. CONC. CPT. C.T. DBL. DIA. DIM. DISP. DP. DR. D.S. DTL. D.W. D.G. EA. ELEV. EQ. EXH. EXT. FAU F.G./FX. F.G. F.F FLUOR. F.M.C. FR. DR. FTG. FLR. GA. G.D. G.F.I. G.I. GL. GYP. BD. H.C. HDR. HGT. INSUL. INT. LAM. LAV. LUM. M.C. MFR. MIN. MTD. MTL. N.I.C. N.T.S. O/ O.C. O.S.A. RM. R.O. S.C. S.H. SHT. SHTHG. SHWR. SIM. SL. SL. GL. S & P STD. S.V. S.D. TEMP. THK. TYP. U.N.O. V.P. W. W/ WD. WDW. W/H W.I. W.P. ABOVE AIR CONDITIONING ADJUSTABLE ALTERNATE AMPERAGE BOARD CENTER LINE CABINET CEILING CLEAR CONCRETE CARPET CERAMIC TILE DRYER DOUBLE DIAMETER DIMENSION DISPOSAL DEEP DOOR DOWNSPOUT DETAIL DISHWASHER DUAL GLAZED EACH ELEVATION EQUAL EXHAUST EXTERIOR FORCED AIR UNIT FIXED GLASS FINISHED GRADE FINISHED FLOOR FLUORESCENT FLOOR MATERIAL FRENCH DOOR FOOTING FLOOR GAUGE GARBAGE DISPOSAL GROUND-FAULT CIRCUIT INTERRUPTER GALVANIZED IRON GLASS GYPSUM BOARD HOLLOW CORE HEADER HEIGHT INSULATION INTERIOR LAMINATED LAVATORY LUMINOUS MEDICINE CABINET MANUFACTURER MINIMUM MOUNTED METAL NOT IN CONTRACT NOT TO SCALE OVER ON CENTER OUTSIDE AIR ROOM ROUGH OPENING SOLID CORE SINGLE HUNG SHEET SHEATHING SHOWER SIMILAR SLIDING SLIDING GLASS SHELF AND POLE STANDARD SHEET VINYL SMOKE DETECTOR TEMPERED GLASS THICK TYPICAL UNLESS NOTED VAPOR PROOF WASHER WITH WOOD WINDOW WATER HEATER WROUGHT IRON WEATHER PROOF CODE ABBREVIATIONS C.B.C. C.F.C. C.M.C. C.P.C. C.E.C. C.G.B.S. CALIFORNIA BUILDING CODE CALIFORNIA FIRE CODE CALIFORNIA MECHANICAL CODE CALIFORNIA PLUMBING CODE CALIFORNIA ELECTRICAL CODE CALIFORNIA GREEN BUILDING STANDARD FINISHFIN. TOP OF CURBT.O.C. T.O.P.TOP OF PLATE TOP OF SLABT.O.S. CL P.B. PH. PLT. PLYWD. PR. P.T.D.F. R. RAD. R.A.G. REF. REF. REV. PUSH BUTTON PHONE PLATE PLYWOOD PAIR PRESSURE TREATED DOUGLAS FIR RISER RADIUS RETURN AIR GRILL REFRIDGERATOR REFERENCE REVERSE RE/S RE-SAWN PROPERTY LINEPL OTHERWISE I.C.B.O.INTERNATIONAL CONFERENCE OF BUILDING OFFICIALS C.E.E.C.CALIFORNIA ENERGY EFFICIENCY CODE I.C.C.INTERNATIONAL CODE COUNCIL BUILDING CODE DATA LEGEND: BUILDINGS SHALL COMPLY WITH LOCAL AND STATE CODE REGULATIONS PER CITY ORDINANCE OF NEWPORT BEACH, CALIFORNIA: 2019 CALIFORNIA RESIDENTIAL BUILDING CODE 2019 CALIFORNIA MECHANICAL CODE 2019 CALIFORNIA ELECTRICAL CODE 2019 CALIFORNIA PLUMBING CODE 2019 CALIFORNIA ENERGY CODE. 2019 CALIFORNIA GREEN BUILDING CODE TITLE 15 OF THE NEWPORT BEACH MUNICIPAL CODE CEILINGS (BELOW ATTIC) CATHEDRAL CEILINGS EXTERIOR 2X6 WALLS R-30 R-30 INSULATION SCHEDULE DUCT R-6 GLAZING DUAL PANE R-19 FIRE SPRINKLERS - A FIRE SPRINKLER PLAN SHALL BE INSTALLED PER NFPA 13D 2016 (INCLUDING HYDRAULIC CALCULATIONS) SOUND ATTENUATION DESIGN FOR HVAC EQUIPMENT SOLAR PANELS *DEFERRED SUBMITTALS TO BE REVIEWED BY THE PROJECT ARCHITECT OR ENGINEER OF RECORD AND CERTIFIED PRIOR TO SUBMITTAL FOR PLAN CHECK OR APPROVAL BY THE CITY. NEW CONSTRUCTION OF 2-STORY SINGLE RESIDENCE AND 2-CAR GARAGE. REPAIR EXISTING DOCK. ACKNOWLEDGEMENTS PROJECT DESCRIPTION: “ISSUANCE OF A BUILDING PERMIT BY THE CITY OF NEWPORT BEACH DOES NOT RELIEVE APPLICANTS OF THE LEGAL REQUIREMENTS TO OBSERVE COVENANTS, CONDITIONS AND RESTRICTIONS WHICH MAY BE RECORDED AGAINST THE PROPERTY OR TO OBTAIN PLANS. YOU SHOULD CONTACT YOUR COMMUNITY ASSOCIATIONS PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION AUTHORIZED BY THIS PERMIT.” PRIOR TO PERFORMING ANY WORK IN THE CITY RIGHT-OF-WAY AN ENCROACHMENT PERMIT MUST BE OBTAINED FROM THE PUBLIC WORKS DEPARTMENT A CAL-OSHA PERMIT IS REQUIRED FOR EXCAVATIONS DEEPER THAN 5’ AND FOR SHORING AND UNDERPINNING. DEFERRED SUBMITTALS TO BE REVIEWED BY PROJECT ARCHITECT OR ENGINEER OF RECORD AND CERTIFIED PRIOR TO SUBMITTAL FOR PLAN CHECK OR APPROVAL BY THE CITY. OBTAIN FIRE SPRINKLER PERMIT PRIOR TO CALLING FOR ROOF SHEATHING INSPECTION. A CERTIFIED BUILDING HEIGHT CERTIFICATION MUST BE SUBMITTED AT THE FOLLOWING TWO POINTS IN THE CONSTRUCTION PROCESS: A.WHEN CONCRETE SLAB IS POURED. B.AFTER ROOF FRAMING BUT PRIOR TO THE INSTALLATION OF THE ROOF MATERIAL. MEASURE FROM AVERAGE CURB HEIGHT. AN APPROVED ENCROACHMENT PERMIT IS REQUIRED FOR ALL WORK ACTIVITIES IN THE PUBLIC RIGHT-OF-WAY. A PUBLIC WORKS DEPARTMENT ENCROACHMENT PERMIT INSPECTION IS REQUIRED BEFORE THE BUILDING DEPARTMENT PERMIT FINAL CAN BE ISSUED. AT THE TIME OF PUBLIC WORKS DEPARTMENT INSPECTION, IF ANY OF THE EXISTING PUBLIC IMPROVEMENTS SURROUNDING THE SITE IS DAMAGED, NEW CONCRETE SIDEWALK, CURB AND GUTTER, AND ALLEY/STREET PAVEMENT WILL BE REQUIRED. ADDITIONALLY, IF EXISTING UTILITIES INFRASTRUCTURE ARE DEEMED SUBSTANDARD, A NEW 1-INCH WATER SERVICE, WATER METER BOX, SEWER LATERAL AND/OR CLEANOUT WITH BOX AND LID WILL BE REQUIRED. 100% OF THE COST SHALL BE BORNE BY THE PROPERTY OWNER (MUNICIPAL CODES 14.24.020 AND 14.08.030). SAID DETERMINATION AND THE EXTENT OF THE REPAIR WORK SHALL BE MADE AT THE DISCRETION OF THE PUBLIC WORKS INSPECTOR. AN ENCROACHMENT AGREEMENT IS REQUIRED FOR ALL NON-STANDARD IMPROVEMENTS WITHIN THE PUBLIC RIGHT OF WAY AND PUBLIC UTILITIES EASEMENT. ALL NON-STANDARD IMPROVEMENTS SHALL COMPLY WITH CITY COUNCIL POLICY L-6. POOLS, SPAS, WALLS, FENCES, PATIO COVERS AND OTHER FREESTANDING STRUCTURES REQUIRE SEPARATE REVIEWS AND PERMITS. FENCES, HEDGES, WALLS, RETAINING WALLS, GUARDRAILS AND HANDRAILS OR ANY COMBINATION THEREOF SHALL NOT EXCEED 42 INCHES FROM EXISTING GRADE PRIOR TO CONSTRUCTION WITHIN THE REQUIRED FRONT SETBACK AREA(S). A SEPARATE PERMIT AND REVIEW IS REQUIRED FOR OUTDOOR HVAC EQUIPMENT. SURVEYOR OR ENGINEER SHALL PERMANENTLY MONUMENT PROPERTY CORNERS OR OFFSETS BEFORE STARTING GRADING OWNER: THE 944 VIA LIDO NORD TRUST 18101 VON KARMAN AVE. STE. 750 IRVINE CA 92612 PH: 949.53.5334 CONTACT: KELLY ROHFELD DESIGNER / CONTRACTOR: W.T. DURANT, INC. 2259 ORANGE AVENUE SIGNAL HILL, CA 90755 PH: 562.424.8816 FX: 562.424.8440 CONTACT: BILL DURANT 44 SHEETS SOILS ENGINEER: W/O 586619-01_JAN 07, 2020 COAST GEOTECHNICAL, INC. 1200 W. COMMONWEALTH AVENUE FULLERTON, CA 92833 PH: 714. 870.1211 CONTACT: DAN HERC CIVIL ENGINEER/ GRADING & DRAINAGE CRF ENGINEERING 6782 STANTON AVENUE, STE. A BUENA PARK, CA 90621 PH:714.522.2266 F:714.752.5384 CONTACT: CESAR RAMIREZ STRUCTURAL ENGINEER: EJD ENGINEERING 14726 RAMONA AVE. (410-WI) CHINO, CA 91710 PH: 909.517.2451 CONTACT: ERNEST DE LEON DEPARTMENT STAMP APPROVALS ARCHITECTURAL A0.0 COVER / INDEX SHEET GN.1 GENERAL NOTES GN.2 GENERAL NOTES GN.3 GENERAL NOTES GN.4 GENERAL NOTES/CAL GREEN GN.5 BEST MANAGEMENT PRACTICES GN.6 CALGREENCOMPLIANCE GN.7 CONDITIONS OF APPROVAL RESLOUTION GN.8 FIRE/OCCUPANCY SEPARATION A1.0 SITE SURVEY A1.1 PROPOSED SITE PLAN A2.1 FIRST FLOOR PLAN A2.2 SECOND FLOOR PLAN A2.3 ROOF PLAN A3.1 EXTERIOR ELEVATIONS A3.2 EXTERIOR ELEVATION A5.1 FIRST FLOOR ELECTRICAL LAYOUT A5.2 SECOND FLOOR ELECTRICAL LAYOUT A6.1 DOOR AND WINDOW SCHEDULE AD1 TYPICAL/MISC DETAILS AD2 DOOR AND WINDOW DETAILS AD3 ROOF DETAILS STRUCTURAL S1 STRUCTURAL GENERAL NOTES S1.1 STRUCTURAL OBSERVATIONS S2 FOUNDATION PLAN S3 FIRST FLOOR SHEARWALL AND HEADER FRAMING PLAN S4 FIRST FLOOR PLATE HEIGHT FRAMING S5 SECOND FLOOR SHEARWALL & HEADER FRAMING PLAN S6 ROOF FRAMING PLAN SD1 TYPICAL DETAILS SD2 FOUNDATION DETAILS SD3 WALL FRAMING DETAILS SD4 FLOOR FRAMING DETAILS SD5 ROOF FRAMING DETAILS SD6 MOMENT CONNECTION DETAILS WSW2 WOOD STRONG WALL DETAILS GRADING C1 GENERAL GRADING NOTES C2 TOPOGRAPHIC SURVEY MAP C3 PRECISE GRADING & DRAINAGE PLAN C4 EROSION CONTROL PLAN C5 WATER & SEWER PLAN C6 GRADING & DRAINAGE DETAILS C9 WQMP SITE PLAN INTERIOR FLOOR R-19 AVERAGE CURB HEIGHT IS 12.55'. A CERTIFIED BUILDING HEIGHT CERTIFICATION MUST BE SUBMITTED IMMEDIATELY AFTER THE ROOF MATERIAL HAS BEEN INSTALLED. THE MEASUREMENT MUST COME FROM THE AVERAGE CURB HEIGHT OF 12.55' AND THE MAXIMUM HEIGHT CANNOT EXCEED 36.55' (24'-0”). GENERAL NOTES GN.1 PLOT DATE: SCALE: DESIGN BY: DRAWN BY: CHECKED DATE: FILE NAME: SH E E T S : REVISIONS: BILL DURANT Th e 9 4 4 V i a L i d o N o r d T r u s t 94 4 V i a L i d o N o r d Ne w p o r t B e a c h , C A 9 2 6 6 3 P 562.424.8816 F 562.424.8440 STAMP: BI L L D U R A N T De s i g n e r / B u i l d e r 22 5 9 O r a n g e A v e n u e Si g n a l H i l l , C a l i f o r n i a 9 0 7 5 5 AS NOTED Z: \ P r o j e c t F o l d e r s \ P r o j e c t s - 2 0 1 8 \ 9 4 4 V i a L i d o N o r d T r u s t \ 3 - P l o t S h e e t s \ G N G e n e r a l N o t e s . d w g GN General Notes BI L L D U R A N T De s i g n e r / B u i l d e r 22 5 9 O r a n g e A v e n u e Si g n a l H i l l , C a l i f o r n i a 9 0 7 5 5 July 24, 2020 RM / KC AS NOTED Z: \ P r o j e c t F o l d e r s \ P r o j e c t s - 2 0 1 8 \ 9 4 4 V i a L i d o N o r d T r u s t \ 3 - P l o t S h e e t s \ G N G e n e r a l N o t e s . d w g GN General Notes GENERAL NOTES GN.2 PLOT DATE: SCALE: DESIGN BY: DRAWN BY: CHECKED DATE: FILE NAME: SH E E T S : REVISIONS: BILL DURANT Th e 9 4 4 V i a L i d o N o r d T r u s t 94 4 V i a L i d o N o r d Ne w p o r t B e a c h , C A 9 2 6 6 3 P 562.424.8816 F 562.424.8440 STAMP: BI L L D U R A N T De s i g n e r / B u i l d e r 22 5 9 O r a n g e A v e n u e Si g n a l H i l l , C a l i f o r n i a 9 0 7 5 5 AS NOTED Z: \ P r o j e c t F o l d e r s \ P r o j e c t s - 2 0 1 8 \ 9 4 4 V i a L i d o N o r d T r u s t \ 3 - P l o t S h e e t s \ G N G e n e r a l N o t e s . d w g GN General Notes BI L L D U R A N T De s i g n e r / B u i l d e r 22 5 9 O r a n g e A v e n u e Si g n a l H i l l , C a l i f o r n i a 9 0 7 5 5 July 24, 2020 RM / KC AS NOTED Z: \ P r o j e c t F o l d e r s \ P r o j e c t s - 2 0 1 8 \ 9 4 4 V i a L i d o N o r d T r u s t \ 3 - P l o t S h e e t s \ G N G e n e r a l N o t e s . d w g GN General Notes GENERAL NOTES GN.3 PLOT DATE: SCALE: DESIGN BY: DRAWN BY: CHECKED DATE: FILE NAME: SH E E T S : REVISIONS: BILL DURANT Th e 9 4 4 V i a L i d o N o r d T r u s t 94 4 V i a L i d o N o r d Ne w p o r t B e a c h , C A 9 2 6 6 3 P 562.424.8816 F 562.424.8440 STAMP: BI L L D U R A N T De s i g n e r / B u i l d e r 22 5 9 O r a n g e A v e n u e Si g n a l H i l l , C a l i f o r n i a 9 0 7 5 5 AS NOTED Z: \ P r o j e c t F o l d e r s \ P r o j e c t s - 2 0 1 8 \ 9 4 4 V i a L i d o N o r d T r u s t \ 3 - P l o t S h e e t s \ G N G e n e r a l N o t e s . d w g GN General Notes BI L L D U R A N T De s i g n e r / B u i l d e r 22 5 9 O r a n g e A v e n u e Si g n a l H i l l , C a l i f o r n i a 9 0 7 5 5 July 24, 2020 RM / KC AS NOTED Z: \ P r o j e c t F o l d e r s \ P r o j e c t s - 2 0 1 8 \ 9 4 4 V i a L i d o N o r d T r u s t \ 3 - P l o t S h e e t s \ G N G e n e r a l N o t e s . d w g GN General Notes – – – ’ ’ “ ” ’ “ ” ’ ” ½ ’ ≤ – – – ’ – “” – MANDATORY REQS. CG GN.4 GENERAL NOTES PLOT DATE: SCALE: DESIGN BY: DRAWN BY: CHECKED DATE: FILE NAME: SH E E T S : REVISIONS: BILL DURANT Th e 9 4 4 V i a L i d o N o r d T r u s t 94 4 V i a L i d o N o r d Ne w p o r t B e a c h , C A 9 2 6 6 3 P 562.424.8816 F 562.424.8440 STAMP: BI L L D U R A N T De s i g n e r / B u i l d e r 22 5 9 O r a n g e A v e n u e Si g n a l H i l l , C a l i f o r n i a 9 0 7 5 5 AS NOTED Z: \ P r o j e c t F o l d e r s \ P r o j e c t s - 2 0 1 8 \ 9 4 4 V i a L i d o N o r d T r u s t \ 3 - P l o t S h e e t s \ G N G e n e r a l N o t e s . d w g GN General Notes BI L L D U R A N T De s i g n e r / B u i l d e r 22 5 9 O r a n g e A v e n u e Si g n a l H i l l , C a l i f o r n i a 9 0 7 5 5 July 24, 2020 RM / KC AS NOTED Z: \ P r o j e c t F o l d e r s \ P r o j e c t s - 2 0 1 8 \ 9 4 4 V i a L i d o N o r d T r u s t \ 3 - P l o t S h e e t s \ G N G e n e r a l N o t e s . d w g GN General Notes Best Management Practices Eff: 01-07-2013 Rev: 04-04-2017 Long Beach has two drainage systems – the sewers and the storm drains. The storm drain system was designed to prevent flooding by carrying excess rainwater away from city streets out to the ocean. Because the system contains no filters, it now serves the unintended function of carrying urban pollution straight to the ocean. This Information Bulletin will describe how to prevent ocean pollution from “stormwater” or “urban runoff” for residential projects. Best management practices, such as handling, storing and disposing of materials properly prevents construction site pollutants from entering the storm drains. GENERAL BUSINESS PRACTICES CD4(2) WATER CONSERVATION PRACTICE Purpose: To reduce the discharge of pollutants from construction sites by using construction water that does not cause erosion or wash materials off-site. Standards:  Discourage washing of equipment on site.  Avoid using water to clean construction areas. Sweep paved areas where practical.  Direct construction water run-off to areas where it can soak into the ground.  Apply water for dust control moderately so run-off does not occur. CA1O MATERIAL DELIVERY AND STORAGE Purpose: To reduce the discharge of pollutants during the delivery and storage process by minimizing the contact of materials with run-off. Standards:  Designate storage areas at the project site.  Prevent spills or leakage of liquid materials from contaminating soil or soaking into the ground by placing storage areas on impervious surfaces. Do not store hazardous chemicals, drums, or bagged materials directly on the ground.  Provide curbs or dikes around the perimeter of material storage areas.  Store materials indoors when available.  Minimize hazardous material storage on-site.  Keep hazardous materials in their original containers and keep them well labeled.  Keep ample supply of appropriate spill clean-up material near storage areas.  Contain and clean up any spill immediately. Information Bulletin BU-038  Construction Activities / Best Management Practices CA11 MATERIAL USE Purpose: To reduce the discharge of pollutants by properly storing and utilizing materials. Standards:  Use materials only where and when needed to complete the construction activity.  Follow manufacturers instructions regarding the preparation, use, and disposal of materials.  Avoid exposing applied materials to rainfall and run-off unless sufficient time has allowed for them to dry. CA12 SPILL PREVENTION AND CONTROL Purpose: To reduce the discharge of pollutants from spills by preventing, containing and clean-up spills. Standards:  Hold regular meetings to discuss and reinforce appropriate disposal procedures.  Use absorbent materials on small spills rather then hosing down or burying the spill.  For significant or hazardous spills that cannot be controlled by personnel in the immediate vicinity, notify local emergency response by calling 911. CA2O SOLID WASTE MANAGEMENT Purpose: To reduce the discharge of pollutants as a result of the creation, stockpiling and removal of litter and other construction waste. Standards:  Collect site trash regularly, daily during rainy and windy conditions.  Keep solid materials shielded by using either a covered dumpster or other enclosed trash container that limits contact with rain, run-off, and/or scattering due to winds.  Make sure that toxic wastes and chemicals are not disposed of in dumpsters designed for construction debris. CA21 HAZARDOUS WASTE MANAGEMENT Purpose: To reduce the discharge of pollutants by the proper storage and disposal of waste. Standards:  Sites with existing structures may contain waste which must be disposed of in accordance with federal, state, and local regulations which include sandblasting grit mixed with lead, cadmium, or chromium based paints and asbestos.  Major contamination, large spills, and other serious hazardous waste incidents require immediate response from specialists.  Keep liquid or semi-liquid hazardous waste in appropriate containers and under cover.  Clearly mark on all hazardous waste containers which materials are acceptable for the container.  Place hazardous waste containers in secondary containment.  Make sure that toxic wastes and chemicals are not disposed of in dumpsters designed for construction debris. Information Bulletin BU-038  Construction Activities / Best Management Practices CA23 CONCRETE WASTE MANAGEMENT Purpose: To reduce the discharge of Portland cement, concrete slurries and asphalt by implementing appropriate wash-out procedures, slurry containment, housekeeping and disposal practices. Standards:  Do not allow slurry residue from wet coring or saw-cutting to enter storm drains.  Shovel or vacuum slurry residue and dispose in a temporary pit.  Designate areas to be used for washout of vehicles transporting concrete.  Washout areas shall have a temporary pit or berm area of sufficient volume to completely contain all liquid and waste concrete.  Once the concrete wastes are washed into the designated areas and allowed to harden, the concrete can be properly disposed. CA3O VEHICLE AND EQUIPMENT CLEANING Purpose: To reduce the discharge of pollutants by cleaning equipment and related activities offsite when practical. Standards:  Clean all vehicles and equipment that regularly enter and leave the construction site.  Design wash area with a sump to allow collection and disposal of wash water.  Do not use solvents or steam to clean vehicles or equipment on site. CA31 VEHICLE AND EQUIPMENT FUELING Purpose: To reduce the discharge of pollutants as a result of vehicle and equipment fueling by preventing leaks and spillage. Standards:  Locate fueling areas on a paved surface where practical.  Protect fueling areas with berms and/or dikes to prevent run-on, run-off, and to contain spills.  Absorbent materials shall be used on small spills instead of hosing down or burying.  Keep an ample supply of spill cleanup material on the site. CA32 VEHICLE AND EQUIPMENT MAINTENANCE Purpose: To reduce the discharge of pollutants as a result of vehicle and equipment maintenance by conducting these activities off-site or in a designated area. Standards:  Locate on paved surfaces where practical.  Use berms to protect maintenance areas from run-on.  Do not dump fuels and lubricants onto the ground.  Do not place used oil in a dumpster or pour into a storm drain. EROSION CONTROL MEASURES AND BEST MANAGEMENT PRACTICES 1. ALL AREAS OF SITE DISTURBANCE SHALL BE IDENTIFIED BY THE INSTALLATION OF PERFORATED PLASTIC FENCING WITH A BRIGHT CONTRASTING COLOR SO THE AREAS OF DISTURBANCE ARE CLEARLY IDENTIFIED THROUGHOUT THE ENTIRE CONSTRUCTION PERIOD. THE FENCE SHALL BE MAINTAINED THROUGHOUT THE CONSTRUCTION PERIOD 2. FIBER ROLL BARRIERS SHALL CONSIST OF MILLED WOOD OR OTHER NATURAL FIBERS SEWN INTO A CIRCULAR WEAVE FABRIC. FIBER ROLLS SHALL BE INSTALLED ON THE CONTOUR LINE PERPENDICULAR TO THE SLOPE DIRECTION AND KEYED INTO A CONCAVE TRENCH OF AT LEAST THREE INCHES OF DEPTH. ROLLS SHALL BE STAKED ON BOTH SIDES EVERY 12" STAGGERED. WHEN TWO ROLLS ABUT THE ENDS SHALL CREATE A TIGHT JOINT TO PREVENT SEDIMENT FROM ESCAPING. 3. ENTIRE AREAS BELOW DECKS SHALL BE COVERED WITH 6" DEEP 3/4" CLEAN DRAINROCK 4. PROPER INSTALLATION AND MAINTENANCE OF ALL EROSION CONTROL MEASURES SHALL BE PRACTICED THROUGHOUT THE ENTIRE CONSTRUCTION PERIOD 5. UNUSED CONSTRUCTION MATERIALS, DEBRIS AND EXCAVATION/GRADING MATERIALS SHALL BE CLEANED AND REMOVED FROM SITE. 6. STORAGE OF ALL CONSTRUCTION MATERIALS AND PARKING SHALL BE RESTRICTED TO AREAS THAT ARE CAPABLE OF ELIMINATING DEBRIS FROM BEING CARRIED OFF SITE BY BOTH PEDESTRIAN AND VEHICULAR TRAFFIC. 7. DRIVEWAYS AND CONSTRUCTION ACCESS SHALL HAVE TRACK OFF CONTROL. PRIOR TO WINTER CONSTRUCTION (1ST OF MAY - 15TH OF OCTOBER, ALL CONSTRUCTION ACCESS POINTS SHALL BE COVERED WITH GRAVEL OR CRUSHED ROCK. FIBER ROLLS SHALL BE PLACED ALONG FULL ACCESS WIDTH AND RETURNED 3 FEET UPSLOPE DURING ALL CONSTRUCTION ACTIVITIES. FIBER ROLLS MAY BE MOVED DURING ACCESS ONLY AND REPOSITIONED IMMEDIATELY. FIBER ROLLS SHALL BE REPLACED IF THE ROLL DETERIORATES DUE TO CONTINUED REPOSITIONING OR DAMAGE DUE TO ANY CONSTRUCTION ACTIVITIES 8.IF CONSTRUCTION ACTIVITY WILL OCCUR BETWEEN 15TH OF OCTOBER AND THE 1ST OF MAY, DRIVEWAYS SHALL BE PAVED IF THE SLOPE OF THE DRIVEWAY EXCEEDS 10% OR IF THE DRIVEWAY WILL BE USED FOR THE STORAGE OF MATERIALS OR VEHICULAR ACCESS. 9. ALL AREAS OF SITE DISTURBANCE SHALL BE COVERED WITH 2" SHREDDED REDWOOD MULCH OR HYRDOSEEDED FOR WINTERIZATION AS WELL AS AREAS THAT ARE NOT LANDSCAPED AT FINAL GRADING. 10. ALL DIRT STOCKPILES AND AREAS SHALL BE COVERED WITH VISQUEEN AND STAKED/WEIGHTED TO PREVENT MOVEMENT OF BARRIER DUE TO WIND. 11. ALL DISTURBED AREAS THAT ARE SLOPED UP TO A 3:1 SLOPE SHALL BE COVERED WITH HYRODSEED AND OR WOODCHIP MULCH. SLOPES EXCEEDING 3:1 SHALL BE FIRST COVERED WITH A BIODEGRADABLE GEOTEXTILE FABRIC INSTALLED PER THE MANUFACTURER'S SPECIFICATIONS AND HYDROSEEDED. 12. FILTER FENCE REQUIREMENTS A. SILT FENCE SHALL BE CONSTRUCTED BEFORE UPSLOPE LAND DISTURBANCE BEGINS. B. ALL SILT FENCES SHALL BE PLACED AS CLOSE TO THE CONTOUR AS POSSIBLE SO THAT WATER WILL NOT CONCENTRATE AT LOW POINTS IN THE FENCE AND SO THAT SMALL SWALES OR DEPRESSIONS WHICH MAY CARRY SMALL CONCENTRATED FLOWS TO THE SILT FENCE ARE DISSIPATED ALONG ITS LENGTH. C. TO PREVENT WATER PONDED BY THE SILT FENCE FROM FLOWING AROUND THE ENDS, EACH END SHALL BE CONSTRUCTED UPSLOPE SO THAT THE ENDS ARE AT A HIGHER ELEVATION. D. WHERE POSSIBLE, SILT FENCE SHALL BE PLACED ON THE FLATTEST AREA AVAILABLE. E. WHERE POSSIBLE, VEGETATION SHALL BE PRESERVED FOR 5 FT. (OR AS MUCH AS POSSIBLE) UPSLOPE FROM THE SILT FENCE. IF VEGETATION IS REMOVED, IT SHALL BE REESTABLISHED WITHIN 7 DAYS FROM THE INSTALLATION OF THE SILT FENCE. F. THE HEIGHT OF THE SILT FENCE SHALL BE A MINIMUM OF 16 IN. ABOVE THE ORIGINAL GROUND SURFACE. G. THE SILT FENCE SHALL BE PLACED IN A TRENCH CUT A MINIMUM OF 6 IN. DEEP. THE TRENCH SHALL BE CUT WITH A TRENCHER, CABLE LAYING MACHINE, OR OTHER SUITABLE DEVICE WHICH WILL ENSURE ADEQUATE UNIFORM TRENCH DEPTH. H. THE SILT FENCE SHALL BE PLACED WITH THE METAL STAKES ON THE DOWNSLOPE SIDE OF THE GEOTEXTILE AND SO THAT THE 8 IN. OF CLOTH ARE BELOW THE GROUND SURFACE. EXCESS MATERIAL SHALL LIE ON THE BOTTOM OF THE 6-IN. DEEP TRENCH. THE TRENCH SHALL BE BACKFILLED AND COMPACTED. I. SEAMS BETWEEN SECTIONS OF SILT FENCE SHALL BE OVERLAPPED WITH THE END STAKES OF EACH SECTION WRAPPED TOGETHER BEFORE DRIVING INTO THE GROUND. J. MAINTENANCE - SILT FENCE SHALL ALLOW RUNOFF TO PASS ONLY AS DIFFUSE FLOW THROUGH THE GEOTEXTILE. IF RUNOFF OVERTOPS THE SILT FENCE, FLOWS UNDER OR AROUND THE ENDS, OR IN ANY OTHER WAY BECOMES A CONCENTRATED FLOW, ONE OF THE FOLLOWING SHALL BE PERFORMED, AS APPROPRIATE: 1) THE LAYOUT OF THE SILT FENCE SHALL BE CHANGED, 2) ACCUMULATED SEDIMENT SHALL BE REMOVED, OR 3) OTHER PRACTICES SHALL BE INSTALLED. 13. CRITERIA FOR SILT FENCE MATERIALS A. FENCE STAKES - THE LENGTH SHALL BE A MINIMUM OF 32 IN. LONG. STAKES SHALL BE HEAVY GUAGE GALVANIZED METAL. THE MAXIMUM SPACING BETWEEN POSTS SHALL BE 10 FT. B. SILT FENCE FABRIC SHALL HAVE A WIRE BACKING AND MEET THE FOLLOWING CRITERIA (SEE CHART BELOW) FABRIC PROPERTIES GRAB TENSILE STRENGTH MULLEN BURST STRENGTH SLURRY FLOW RATE EQUIVALENT OPENING SIZE ULTRAVIOLET RADIATION STAB. 14. INFILTRATION TRENCH INSTALLATION A. INFILTRATION TRENCHES SHALL BE INSTALLED LEVEL WHERE POSSIBLE. ON SLOPES, THE TRENCH SIZE MAY BE REDUCED TO 18" WIDE BY 8" DEEP AND FUNCTION SOLELY AS CONVEYANCE STRUCTURES. AT THE LOW POINT OF THE CONVEYANCE TRENCH A DRYWELL MUST BE INSTALLED SIZED TO THE SAME VOLUME AS NOTED FOR THE TRENCH. AN ALTERNATE METHOD IS TO PROVIDE STEPPED TRENCHES WITH STONE BAFFLES THAT ALLOW FOR LEVEL DISTRIBUTION OF THE RUNOFF INTO THE TRENCH. B. INFILTRATION TRENCHES LOCATED INSIDE THE DRIPLINES OF TREES SHALL BE EXCAVATED BY HIND TO HELP ELIMINATE THE POTENTIAL DAMAGE TO THE TREES ROOT BALL. SHOULD TAP ROOTS BE ENCOUNTERED, SPAN THE TRENCH AROUND THE TAP ROUTE WITHOUT DAMAGING THE TAP ROOT. C. INFILTRATION TRENCHES AND DRYWELLS SHALL BE LINED WITH LARGER STONES AT THE PERIMETER. PLACE GEOTEXTILE FILTER FABRIC OVER LARGER STONES AND THEN FILL 3/4" DRY CLEAN GRAVEL OVER THE FILTER FABRIC FLUSH TO GRADE D. INFILTRATION TRENCHES ALONG DRIVEWAYS SHALL BE INSTALLED IN A SIMILAR FASHION TO DRIP LINE TRENCHES. THEY MUST BE INSTALLED AS CLOSE TO LEVEL AS POSSIBLE. WHERE THE DRIVEWAY IS SLOPED, THE TRENCH WILL ACT AS A CONVEYANCE SYSTEM TO A LARGER DRYWELL AT THE BASE. SLOTTED STEEL DRAINS MAY BE INSTALLED IN STEEP DRIVEWAYS IN LIEU OF THE CONVEYANCE TRENCH. IN THIS CASE THE DRIVEWAY MUST NOT HAVE CROSS SLOPE IN ORDER TO ALLOW ALL THE RUNOFF TO ENTER THE DRAIN. THE DRAIN WOULD THEN DISCHARGE INTO A DRYWELL SIZED FOR THE VOLUME OF THE INFILTRATION TRENCH. 15. THE GOAL DURING CONSTRUCTION IS TO MINIMIZE OR COMPLETELY ELIMINATE THE POTENTIAL FOR EROSION AND SEDIMENTATION UNTIL THE FINAL BMP'S ARE INSTALLED AND FULLY FUNCTIONING. IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL, MAINTAIN AND MAKE EFFECTIVE ALL BMP MEASURES TO MAINTAIN THIS GOAL WITH ALL TEMPORARY AND PERMANENT BMP'S. PERMANENT BMP'S ARE SIZED FOR A 20 YEAR/1 HOUR STORM AND IF INSTALLED PROPERLY CAN HELP PREVENT THE DISCHARGE OF DEGRADED RUN-OFF WATER FROM CONSTRUCTION SITES AND COMPLETED PROJECTS. WHILE EXTENSIVE MEASURES ARE IDENTIFIED ON THESE PLANS, THE CONTRACTOR MUST VERIFY THAT THE INSTALLATION MEETS THE VARIOUS UNANTICIPATED VARIABLES THAT ARE COMMONLY ENCOUNTERED DURING THE CONSTRUCTION PROCESS. VALUES 90 LB. MIN. 180 PSI MIN. 03 GAL/MIN/FT MAX. 40-80 90% MIN. TEST METHOD ASTM D1682 ASTM D 3786 US STD. SIEVE CW-02215 ASTM - G - 26 A1.4 8 Not Used NTS A1.4 5 Swale NTS A1.4 9 Not Used NTS A1.4 6 Bio Retention Area NTS A1.4 7 Not Used NTS A1.4 4 Filter Fence Temporary BMP NTS LANDSCAPED AREA OVER RETENTION AREA. PERMEABLE SOIL MIX SOIL/COMPOST/SAND MIXTURE. PROVIDE SWALE TOWARDS CENTER TO FORCE DRAINAGE INTO RETENTION DEVICE. LINE TRENCH WITH FILTER FABRIC ON ALL SIDES. OVERLAP FABRIC A MIN. OF 6" ON TOP. 34" CLEAN DRAIN ROCK 3"-5" LARGER STONE LINING- NOT COUNTED IN TRENCH SIZE. COMPACTED BASE OVER COMPACTED SUBGRADE 4" DIA. PERFORATED PVC PIPE IN FROM CONVEYANCETRENCHES REFER TO SITE PLAN INFILTRATION SCHEDULE FOR ACTUAL SIZE OF RETENTION AREA AND SIZE ACCORDINGLY. DRIPLINE FROM ROOF EAVE CARRY LOOSE NATURAL FILL/REVEG MATERIAL AND OR LANDSCAPING WHERE SHOWN 3" OVER TOP OF TRENCH ALIGN TRENCH SO THAT THE DRIPLINE IS 13 THE TRENCH WIDTH ON THE BUILDING SIDE LINE TRENCH WITH FILTER FABRIC ON ALL SIDES. OVERLAP FABRIC A MIN. OF 6" ON TOP OF TRENCH. 34" CLEAN DRAIN ROCK 3"-5" LARGER STONE LINING- NOT COUNTED IN TRENCH SIZE. 18" WIDE X 6" DEEP CONVEYANCE TRENCH WITH 4" DIA. PERFORATED PIPE CONNECTED TO BIO RETENTION AREA OR TIED TO ROCKLINED SWALE - SLOPE PERF. PIPE MIN, 2% DOWN TO EACH TERMINATION ELEMENT. CARRY LOOSE NATURAL FILL/REVEG MATERIAL AND OR LANDSCAPING WHERE SHOWN 3" OVER TOP OF TRENCH AC PAVING LINE TRENCH WITH FILTER FABRIC ON ALL SIDES. OVERLAP FABRIC A MIN. OF 6" ON TOP OF TRENCH. 34" CLEAN DRAIN ROCK 3"-5" LARGER STONE LINING- NOT COUNTED IN TRENCH SIZE. REFER TO SITE PLAN INFILTRATION TRENCH SCHEDULE FOR PLAN DESIGNATION AND SIZE TRENCH TO BE INSTALLED AS CLOSE AS POSSIBLE TO LEVEL. WHERE COMPLETELY LEVEL, INSTALL 4" PERF. PIPE TO EVENLY DISTRIBUTE WATER. IF GRADING REQUIRES INSTALLATION ON SLOPED SURFACES EXCEEDING 5%, INSTALL STEPPED TRENCH. RAISED BOULDER (10"-16") ENERGY DISSIPATOR EVERY 50' 3-8" STONE-LINED SWALE, 24" WIDE - PITCH AT MIN. 2%. WIDEN TO 42" AT DISSIPATOR ABS PIPE FROM CONVEYANCE TRENCH LINE BOTTOM OF SWALE WITH FILTER FABRIC SET STONES FLUSH TO REVEGETATED AREAS REFER TO LANDSCAPE PLAN. SURFACE SWALES SHALL BE LANDSCAPED WITH SMALL BOULDERS AND NATURAL VEGETATION TO TRANSITION THEIR APPEARANCE WITH THE NATURAL LANDSCAPE. FIBER ROLL BEYOND 2" GALV. MTL. STAKES @ 5'-0" O.C. SET 24" ABOVE GRADE WITH MIN. 8" EMBEDMENT PERMEABLE FILTER FABRIC W/ WIRE BACKING SET 6" BELOW GRADE WITH A MIN. 4" RETURN KEY BELOW GRADE 2X2 WOOD STAKES @ 48" O.C. 12" DIAMETER FIBER ROLL SEDIMENT RETENTION BARRIER. SET FIBER ROLL IN 3" DEEP TRENCH ALWAYS PARALLEL TO CONTOUR LINES (PERPENDICULAR TO SLOPE) A1.4 2 Driveway Infiltration Trench NTS A1.4 3 Conveyance Trench NTS A1.4 1 Fiber Roll Temporary BMP NTS 1BEST MANAGEMENT PRACTICES - EROSION CONTROL 2BEST MANAGEMENT PRACTICES - CONSTRUCTION ACTIVITY PRACTICES BMP BEST MANAGEMENT 3STORM WATER POLLUTION CONTROL GN.5 3L.I.C.A. APPROVAL (PRELIMINARY) PLOT DATE: SCALE: DESIGN BY: DRAWN BY: CHECKED DATE: FILE NAME: SH E E T S : REVISIONS: BILL DURANT Th e 9 4 4 V i a L i d o N o r d T r u s t 94 4 V i a L i d o N o r d Ne w p o r t B e a c h , C A 9 2 6 6 3 P 562.424.8816 F 562.424.8440 STAMP: BI L L D U R A N T De s i g n e r / B u i l d e r 22 5 9 O r a n g e A v e n u e Si g n a l H i l l , C a l i f o r n i a 9 0 7 5 5 AS NOTED Z: \ P r o j e c t F o l d e r s \ P r o j e c t s - 2 0 1 8 \ 9 4 4 V i a L i d o N o r d T r u s t \ 3 - P l o t S h e e t s \ G N G e n e r a l N o t e s . d w g GN General Notes BI L L D U R A N T De s i g n e r / B u i l d e r 22 5 9 O r a n g e A v e n u e Si g n a l H i l l , C a l i f o r n i a 9 0 7 5 5 July 24, 2020 RM / KC AS NOTED Z: \ P r o j e c t F o l d e r s \ P r o j e c t s - 2 0 1 8 \ 9 4 4 V i a L i d o N o r d T r u s t \ 3 - P l o t S h e e t s \ G N G e n e r a l N o t e s . d w g GN General Notes CITY OF NEWPORT BEACH COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION 100 Civic Center Drive | P.O. Box 1768 | Newport Beach, CA 92658-8915 www.newportbeachca.gov | (949) 644-3200 RESIDENTIAL CONSTRUCTION MINIMUM REQUIREMENTS Applicable Standards: 2019 California Residential Code (CRC); 2019 California Building Code (CBC); 2019 California Plumbing Code (CPC); 2019 California Electrical Code (CEC); 2019 California Mechanical Code (CMC); 2019 Building Energy Efficiency Standards (BEES); 2019 California Green Building Standards Code (Cal Green); & Chapter 15 of the Newport Beach Municipal Code (NBMC) GENERAL: 1.Residential building undergoing permitted alterations, additions or improvements shall replace non-compliant plumbing fixtures with water-conserving plumbing fixtures meeting the requirements of 2019 California Green Building Standards Code, Section 4.303.1 Plumbing fixture replacement is required prior to issuance of a certificate of occupancy or final inspection by the Chief Building Official. (Civil Code, Section 1101.1 et seq., NBMC 15.11.010) 2.Issuance of a building permit by the City of Newport Beach does not relieve applicants of the legal requirements to observe covenants, conditions and restrictions, which may be recorded against the property or to obtain plans. You should contact your community associations prior to commencement of any construction authorized by this permit. 3. 4. 5. 6. 7. 8. 9. Prior to performing any work in the City right-of-way an encroachment permit must be obtained from the Public Works Department. A site survey by a licensed surveyor shall be required prior to foundation concrete pour. Garage ceiling height. The minimum unobstructed vertical clearance for parking spaces shall be seven feet, except that the front four feet may have a minimum vertical clearance of four feet. (NBMC 20.40.090 A 4) Utilize one of the city’s approved franchise hauler to recycle and/or salvage a minimum of 65% of the nonhazardous construction and demolition waste. (Cal Green 4.408.1, 4.408.3) Stairways shall not be less than 36 inches clear width. (CRC 311.7.1) The minimum head clearance shall be 6”-8” measured vertically from the sloped line adjoining tread nosing. (CRC 311.7.2) Advisory Note: Homeowners Association (HOA) approval may be required for this improvement. Additional permits are required for detached structures including but not limited to: a.Accessory structures, detached patio covers, and trellises, b. Masonry or concrete fences over 3.5 ft. high, c.Retaining walls over 4 ft. high from the bottom of the foundation to the top of the wall. 2019 CorrList\RESIDENTIALConstructionMinimumReq 02/21/2020 1 3 FIREPLACE: 19.All fireplaces: a. b. c. Factory-built fireplaces, chimneys and all of their components shall be listed and installed in accordance with their listing and manufacturer's installation instructions. (CRC R1004.1) Factory built wood burning fireplaces shall be qualified at the U.S. EPA’s Voluntary Fireplace Program Phase 2 emissions level. (CRC 1004.1.1) Decorative shrouds shall not be installed at the termination of factory-built chimneys except where such shrouds are listed and labeled for use with the specific factory-built chimney system and are installed in accordance with manufacturer's installation instructions. (CRC R1005.2 & CMC 802.5.1.1 & CMC 802.5.4.3) d. e. Horizontal openings are not allowed, for exhaust vents, in walls closer than 3 feet to a property line. (Tables R302.1(1)&(2)). Horizontal vent caps shall be 2 feet clear from property lines. Exhaust openings shall not be directed onto walkways. (R303.5.2) 20. Solid fuel burning fireplaces: a. b. c. d. Provide a permanently anchored gaseous fuel burning pan to the firebox of a solid fuel burning fireplace. Solid fuel burning fireplace must comply with the California Energy Standards mandatory measures. Chimney shall extend at least 2 ft. higher than any portion of the building within 10 ft., but shall not be less than 3 ft. above the highest point where the chimney passes through the roof. (CRC R1003.9) Liquid fueled fireplaces are not allowed for interior use. 21. Direct vent gas appliance fireplace: a. MECHANICAL: 22. Rooms containing bathtubs, showers, spas and similar fixtures shall be provided with an exhaust fan with humidity control sensor having a minimum capacity of 50 CFM ducted to terminate outside the building. (CRC R303.3, Cal Green 4.506.1, CBC 1202.5.2.1, CMC 402.5) 23. Where water closet compartment is independent of the bathroom or shower area, a fan will be required in each area. Bathrooms shall have an exhaust fan with humidity control sensor, min. 50 CFM capacity. (CRC R303.3) 24. Where whole house fans are used in bathroom areas, the fan must run continuously and shall not be tied to a humidity control sensor. (Cal Green 4.506.1(2)) 25.The clothes dryer vent shall not exceed 14 ft. in overall length with maximum two 90 degree elbows. (CMC 504.4.2.1) 26. Environmental air ducts shall terminate min. 3 feet from property line or openings into building, and 10 feet from a forced air inlet. (CMC 502.2.1) 27. Mechanical equipment shall be installed per the manufacture’s installation instructions. (CMC 303.1) 2019 CorrList\RESIDENTIALConstructionMinimumReq 02/21/2020 4 Direct vent sealed-combustion gas appliance fireplace must comply with the Cal Green code requirements and must comply with ANSI Z21.50. (Cal Green 4.503.1) CONSTRUCTION: 10. Pedestrian protection adjacent to public way to be as follows: CBC TABLE 3306.1 PROTECTION OF PEDESTRIANS HEIGHT OF CONSTRUCTION 8 feet or less DISTANCE FROM CONSTRUCTION TO LOT LINE Less than 5 feet 5 feet or more Less than 5 feet 5 feet or more, but not more than one-fourth the height of construction More than 8 feet 5 feet or more, but between one-fourth and one-half the height of construction 5 feet or more, but exceeding one-half the height of construction TYPE OF PROTECTION REQUIRED Construction railings None Barrier and covered walkway Barrier and covered walkway Barrier None 11. All exterior lath and plaster shall have two layers of Grade D paper over wood base sheathing. (CRC R703.7.3, CBC 2510.6) 12. Wall covering of showers or tubs with showers shall be of cement plaster, tile, or approved equal, to a height of not less than 72 inches above drain inlet. Backing for tile shall be cement board or cement plaster. (CRC R307.2, CBC 1209.2.3) 13. Safety glazing shall be provided at the following hazardous locations: (CRC R308.4, CBC 2406.4) a. c. Swinging, bi-fold, and sliding doors. b. When located within 60 inches above the floor of wet surfaces such as tubs, showers, saunas, steam rooms, or outdoor swimming pool. Glazing adjacent to doors: i. Within a 24 inch arc of either vertical edge of doors and within 60 inches of walking surface. ii. Where the glazing is on a wall perpendicular to the plane of the door in a closed position and within 24 inches of the hinge side of an in-swinging door. d. Where glazing area is more than 9 sq. ft. in area, with the bottom edge less than 18 inches above the floor, top edge more than 36 inches above floor, and within 36 inches of a walking surface, measured horizontally. e. f. g. Glazing where the bottom exposed edge of the glazing is less than 36 inches above the plane of the adjacent walking surface of stairways, landings between flights of stairs and ramps. Glazing adjacent to the landing at the bottom of a stairway where the glazing is less than 36 inches above the landing and within 60 inches horizontally of the bottom tread. Glazing in guards and railings. 14. All doors from the house into the pool area shall be equipped with an approved alarm or an approved alternate drowning prevention safety feature. (CBC 3109 (115922)) 15. Smoke alarms shall be installed in the following locations (CRC R314.3, CBC 907.2.11.2, 907.2.11.3 & 907.2.11.4): a.In each sleeping room. b. c. Outside each separate sleeping area in the immediate vicinity of the bedrooms. On each additional story, including basements and habitable attics. 2019 CorrList\RESIDENTIALConstructionMinimumReq 02/21/2020 2 d. e. f. Not less than 3 feet horizontally from the door or opening of a bathroom that contains a bathtub or shower. A minimum of 20 feet horizontally from any permanently installed cooking appliance. Smoke alarms shall be hardwired with battery back-up and interconnected unless exempted in accordance with CRC R314.4 & R314.5 or CBC 907.2.10.5 & 907.2.10.6. 16. Carbon monoxide alarms shall be installed in the following locations (CRC R315.3): a. b. Outside of each sleeping area in the immediate vicinity of the bedroom(s). On every occupiable level of the dwelling unit including basements. c. Where a fuel-burning appliance is located within a bedroom or its attached bathroom, a carbon monoxide alarm shall be installed within the bedroom. Carbon monoxide alarms shall be hardwired with battery back-up and interconnected unless exempted in accordance with CRC R315.6(4). 17. All fenestrations on windows and doors shall have U-factors (0.30 max) and Solar Heat Gain Coefficient (SHGC=0.23 max) values in accordance with T-24 energy calculations. All fenestrations must have temporary and permanent labels. TEMPORARY GENERATOR: 18. Hand operated construction tools powered by electricity must use power provided by Southern California Edison through a temporary pole or available outlet.In the rare case where electricity is not readily available and a portable temporary generator is necessary, then the following restrictions must be adhered to: a. Must be portable and may be easily relocated. b.Temporary generators are to be located a minimum distance from any property line according to the following table: Time in Use Hours 0 – 1 day > 1 day c. Required Setback from Property Line 10 feet 20 feet Required Setback from Adjacent Structures 5 feet 5 feet If the minimum distance cannot be achieved, then the generator shall be located the most extreme distance practical to inhibit noise. Other methods to inhibit noise may be utilized when practical. d. May be operational for a maximum of five consecutive calendar days. After five consecutive calendar days of use, power shall be provided through the use of a temporary power pole. e.Usage is limited to weekdays between the hours from 8:00 AM and 3:30 PM Monday through Friday. No use on the weekends or federal holidays. 28. Domestic range vents to be smooth metallic interior surface. (CMC 504.3) 29. Supply and return air ducts to be insulated at a minimum of R-6. (Cal Energy Code Table 150.1-A.) PLUMBING: 30. Separate water meters are required for all new duplexes. Separate fire risers are required at each water meter. 31. Plumbing Fixtures: a. b. New Construction & Addition/Alterations that increases condition space area, volume, or size (Cal Green 4.303.1): i. Comply with CAL Green Mandatory Requirements Addition & Alteration: Existing fixtures shall be replaced to meet the following requirements: i. Shower Heads: 1.8 gpm @ 80 psi ii. Lavatory Faucets: 1.2 gpm @ 60 psi iii. Kitchen Faucets: 1.8 gpm @ 60 psi iv. Water Closet: 1.28 gallons per flush 32. Clearance for water closet to be a minimum of 24 inches in front, and 15 inches from its center to any side wall or obstruction. (CPC 402.5) 33. 34. The water heater burner to be at least 18 inches above the garage floor, if located in a garage. (CPC 507.13) Install a 3 inch diameter by 3 ft. tall steel pipe embedded in concrete slab for protection of water heaters located in garage. (CPC 507.13.1) 35. Water heaters to be strapped at top and bottom with 1 ½” x 16 gauge strap with 3/8” diameter. X 3” lag bolt each end. (CPC 507.2) 36. ABS and PVC drain waste and vent piping material is limited to 2 stories maximum. (CPC 701.2(2) (a). and 903.1.1) 37. ABS and PVC roof and deck drain material is limited to 2 stories maximum. (CPC 1101.4) 38. Roof and deck drain systems inside the building are required to be installed with directional DWV drainage fittings. (CPC 1101.4 and & 706.0) 39. Cleanouts are required within 2 feet of the connection between the interior roof and deck drain piping system, and the exterior onsite storm drain system. (CPC 1101.13) 40. 41. 42. All hose bibbs shall have vacuum breakers. (CPC 603.5.7) The maximum amount of water closets on a 3 inch horizontal drainage system line is 3. (CPC Table 703.2) The maximum amount of water closets on a 3 inch vertical drainage system line is 4. (CPC Table 703.2) 43. Provide gas line with a min capacity of 200,000 btu for water heater. (Cal Energy Code 150.0(n)) 44. Provide a condensate drain no more than 2 inches above the base of the water heater space. (Cal Energy Code 150.0 (n)) 45. Provide a straight vent pipe from the water heater space to the outside termination from the water heater space. (Cal Energy Code 150.0 (n)) 2019 CorrList\RESIDENTIALConstructionMinimumReq 02/21/2020 5 46. 47. 48. Insulate all hot water pipes. (Cal Energy Code 150.0 (j) (2), and CPC 609.11). Isolation valves are required for tankless water heaters on the hot and cold supply lines with hose bibbs on each valve, to flush the heat exchanger. (Cal Energy Code 110.3 (6)) Install 1 automatic clothes washer connection per one and two family dwelling. (CPC Table 422.1) ELECTRICAL: 49. Electrical service shall be underground for new construction, replacement building, or addition to an existing building exceeds fifty (50) percent of the gross floor area of the existing building. (NBMC 15.32.015) 50. Edison Company approval is required for meter location prior to installation. 51.Field inspectors shall review and approve underground service requirement prior to concrete placement. 52. Service equipment and subpanels shall have a min 30” wide by 36” deep clear work space.(CEC 110.26) 53. All lighting is required shall be high efficacy. (California energy code section 150.0 (k) and Table 150.0-A.) 54. Provide a listed 1 inch raceway to accommodate a dedicated 208/240-volt circuit for future electrical vehicle (EV) charger. (Cal Green 4.106.4.1) 55. All receptacle outlets are required shall be listed tamper resistant (CEC 406.12 and 250.52) 56. Combination type AFCI circuit breakers are required for all 120 volt single phase 15/20 amp branch circuits. Except for bathrooms, garages, and outdoors. (CEC 210.12) 57. A minimum of one dedicated 20 amp circuit is required for a bathroom. (CEC 210.11(C)(3)) 58. GFCI protection is required for all receptacle outlets located outdoors, garages, accessory buildings, bathrooms, crawl spaces, kitchens, laundry areas, kitchen dishwasher branch circuit, garbage disposal, all areas within 6 feet of a sink, and all receptacles within 6 feet of a bathtub or shower stall. (CEC 210.8) 59. Receptacle outlets are not allow within or over a bathtub or shower stall. (CEC 406.9 (C)) 60. Subpanels are not allow to be located in bathrooms or clothes closets. (CEC 240.24 (D) and (E). 61. Circuits sharing a grounded conductor (neutral) with two ungrounded (hot) conductors must use a two pole circuit breaker or an identified handle tie. (CEC 210.4(B)) Group non- cable circuits in panel (CEC 210.4(D)) 62.The receptacle outlets that serve kitchen counter tops, dining room, breakfast area, and pantry, must have a min of 2 dedicated 20 amp circuits. (CEC 210.52 (B)(1)) 63. Kitchen counter tops 12 inches or wider must have a receptacle outlet. (CEC 210.52(C)(1)) 64. Kitchen counter tops must have receptacle outlets so no point along the counter walls is more than 24 inches from a receptacle. (CEC 210.52 (C)(1)) 65. 66. Island and peninsular counter tops must have at least one receptacle. (CEC 210.52(C)( 1),(2),and (3)) The spacing for general receptacle outlets must be located so that no point on any wall, fixed glass, or cabinets is over 6 feet from a receptacle outlet. (CEC 210.52(A)(1)) 2019 CorrList\RESIDENTIALConstructionMinimumReq 02/21/2020 6 67. Hallways 10 feet or more must have at least one receptacle outlet. (CEC 210.52(H)) 68. Garages shall have at least one receptacle for each car space on the interior. The branch circuit supplying the receptacles shall not serve outlets outside of the garage. (CEC 210.52 (G) (1)). 69.Laundry rooms must have at least one dedicated 20 amp receptacle circuit. (CEC 210.11(C) (2)). 70. Provide 120V receptacle within 3 feet of water heater. (Cal Energy Code 150.0 (n) 1 A.) FOUNDATION: 71. Weep screed for stucco at the foundation plate line shall be a minimum of 4 inches above the earth or 2 inches above paved areas. (CRC R703.7.2.1, CBC 2512.1.2) 72.Fasteners and connectors (nails, anchor bolts, etc.) in contact with preservative-treated wood shall be of hot-dipped zinc-coated galvanized steel, stainless steel, silicon bronze or copper.(CRC R317.3, CBC 2304.10.5.1) 1 MIN. CONST. REQS EC/CG 2CAL GREEN MINIMUM REQUIREMENTS GREEN CODE GN.6 MINIMUM CONSTRUCTION REQUIREMENTS PLOT DATE: SCALE: DESIGN BY: DRAWN BY: CHECKED DATE: FILE NAME: SH E E T S : REVISIONS: BILL DURANT Th e 9 4 4 V i a L i d o N o r d T r u s t 94 4 V i a L i d o N o r d Ne w p o r t B e a c h , C A 9 2 6 6 3 P 562.424.8816 F 562.424.8440 STAMP: BI L L D U R A N T De s i g n e r / B u i l d e r 22 5 9 O r a n g e A v e n u e Si g n a l H i l l , C a l i f o r n i a 9 0 7 5 5 AS NOTED Z: \ P r o j e c t F o l d e r s \ P r o j e c t s - 2 0 1 8 \ 9 4 4 V i a L i d o N o r d T r u s t \ 3 - P l o t S h e e t s \ G N G e n e r a l N o t e s . d w g GN General Notes BI L L D U R A N T De s i g n e r / B u i l d e r 22 5 9 O r a n g e A v e n u e Si g n a l H i l l , C a l i f o r n i a 9 0 7 5 5 July 24, 2020 RM / KC AS NOTED Z: \ P r o j e c t F o l d e r s \ P r o j e c t s - 2 0 1 8 \ 9 4 4 V i a L i d o N o r d T r u s t \ 3 - P l o t S h e e t s \ G N G e n e r a l N o t e s . d w g GN General Notes 1 C/O/A NOTES COA 2RESOLUTION NO. 2019-056 RESOLUTION GN.7 CONDITIONS OF APPROVAL Zoning Administrator Resolution No. ZA2019-056 Page 7 of 7 18. Best Management Practices (BMPs) and Good Housekeeping Practices (GHPs) shall be implemented prior to and throughout the duration of construction activity as designated in the Construction Pollution Prevention Plan (CPPP). 19. The discharge of any hazardous materials into storm sewer systems or receiving waters shall be prohibited. Machinery and equipment shall be maintained and washed in confined areas specifically designed to control runoff. A designated fueling and vehicle maintenance area with appropriate berms and protection to prevent spillage shall be provided as far away from storm drain systems or receiving waters as possible. 20. Debris from demolition shall be removed from work areas each day and removed from the project site within 24 hours of the completion of the project. Stock piles and construction materials shall be covered, enclosed on all sites, not stored in contact with the soil, and located as far away as possible from drain inlets and any waterway. 21. Trash and debris shall be disposed in proper trash and recycling receptacles at the end of each construction day. Solid waste, including excess concrete, shall be disposed in adequate disposal facilities at a legal disposal site or recycled at a recycling facility. 22. Prior to the issuance of building permit, the applicant shall pay any unpaid administrative costs associated with the processing of this application to the Planning Division. 23. To the fullest extent permitted by law, applicant shall indemnify, defend and hold harmless City, its City Council, its boards and commissions, officials, officers, employees, and agents from and against any and all claims, demands, obligations, damages, actions, causes of action, suits, losses, judgments, fines, penalties, liabilities, costs and expenses (including without limitation, attorney’s fees, disbursements and court costs) of every kind and nature whatsoever which may arise from or in any manner relate (directly or indirectly) to City’s approval of 944 Via Lido Nord House Demolition, but not limited to, Coastal Development Permit No. CD2018-111 (PA2018-279). This indemnification shall include, but not be limited to, damages awarded against the City, if any, costs of suit, attorneys' fees, and other expenses incurred in connection with such claim, action, causes of action, suit or proceeding whether incurred by applicant, City, and/or the parties initiating or bringing such proceeding. The applicant shall indemnify the City for all of City's costs, attorneys' fees, and damages which City incurs in enforcing the indemnification provisions set forth in this condition. The applicant shall pay to the City upon demand any amount owed to the City pursuant to the indemnification requirements prescribed in this condition. PUBLIC WORKS 24. Existing driveway approach shall be abandoned, and a new curb and gutter shall be installed to match existing curb and gutter. 25. The existing sewer cleanout box shall be removed and covered, and the existing sewer lateral shall be capped at the property line. 01-25-19 Zoning Administrator Resolution No. ZA2019-056 Page 6 of 7 11. This Coastal Development Permit may be modified or revoked by the Zoning Administrator if determined that the proposed uses or conditions under which it is being operated or maintained is detrimental to the public health, welfare or materially injurious to property or improvements in the vicinity or if the property is operated or maintained so as to constitute a public nuisance. 12. Prior to issuance of building permits, a copy of the Resolution, including conditions of approval Exhibit “A,” shall be incorporated into the Building Division and field sets of plans. 13. Prior to issuance of a building permit, the applicant shall submit a final construction erosion control plan. The plan shall be subject to review and approval by the Building Division. 14. Prior to issuance of a building permit, the applicant shall submit to the Planning Division an additional copy of the approved landscape plans for inclusion in the Coastal Development file. The plans shall be identical to those approved by all City departments for building permit issuance. The approved copy shall include architectural sheets only and shall be reduced in size to 11 inches by 17 inches. The plans shall accurately depict the elements approved by this Coastal Development Permit. 15. Should the property be sold or otherwise come under different ownership, any future owners or assignees shall be notified of the conditions of this approval by either the current business owner, property owner or the leasing agent. 16. This approval does not authorize any new or existing improvements (including landscaping) on State tidelands, public beaches, or the public right-of-way. 17. The applicant is responsible for compliance with the Migratory Bird Treaty Act. In compliance with the (MBTA), grading, brush removal, building demolition, tree trimming, and similar construction activities shall occur between August 16 and January 31, outside of the peak nesting period. If such activities must occur inside the peak nesting season from February 1 to August 15, compliance with the following is required to prevent the taking of Native Birds pursuant to MBTA: A. The construction area shall be inspected for active nests. If birds are observed flying from a nest or sitting on a nest, it can be assumed that the nest is active. Construction activity within 300 feet of an active nest shall be delayed until the nest is no longer active. Continue to observe the nest until the chicks have left the nest and activity is no longer observed. When the nest is no longer active, construction activity can continue in the nest area. B. It is a violation of state and federal law to kill or harm a native bird. To ensure compliance, consider hiring a biologist to assist with the survey for nesting birds, and to determine when it is safe to commence construction activities. If an active nest is found, one or two short follow-up surveys will be necessary to check on the nest and determine when the nest is no longer active. 01-25-19 Zoning Administrator Resolution No. ZA2019-056 Page 5 of 7 EXHIBIT “A” CONDITIONS OF APPROVAL PLANNING 1. 2. 3. The development shall be in substantial conformance with the approved site plan and landscape plans stamped and dated with the date of this approval (except as modified by applicable conditions of approval). The demolition of the existing single-family dwelling shall be in substantial conformance with the approved demolition plan stamped and dated with the date of this approval (except as modified by applicable conditions of approval). Revisions to the approved plans may require an amendment to this Coastal Development Permit or the processing of a new coastal development permit. 4. Coastal Development Permit No. CD2018-111 shall expire unless exercised within 24 months from the date of approval as specified in Section 21.54.060 (Time Limits and Extensions) of the Newport Beach Municipal Code, unless an extension is otherwise granted. 5.Landscaping of the site shall conform to the requirements of Section 21.30.075 (Landscaping) and Section 21.30.085 (Water Efficient Landscaping) of the Local Coastal Program Implementation Plan. Plant materials shall be selected for low-water demand and drought tolerance, and the planting of invasive species shall be prohibited. 6. 7. Landscaping of the site shall conform to Section 14.17 (Water Efficient Landscape Ordinance) of the Newport Beach Municipal Code. All landscape materials and irrigations systems shall be maintained in accordance with the approved erosion control plan. All landscaped areas shall be maintained in a healthy and growing conditions and shall receive regular pruning, fertilizing, mowing and trimming. All landscaped areas shall be kept free of weeds and debris. All irrigation systems shall be kept operable, including adjustments, replacements, repairs, and cleaning as part of regular maintenance. 8. 9. Construction activities shall comply with Newport Beach Municipal Code (NBMC) Section 10.28.040, which restricts hours of noise-generating construction activities to between the hours of 7 a.m. and 6:30 p.m., Monday through Friday. Noise-generating construction activities are not allowed on Saturdays, Sundays or Holidays. The project is subject to all applicable City ordinances, policies, and standards, unless specifically waived or modified by the conditions of approval. 10. The applicant shall comply with all federal, state, and local laws. Material violation of any of those laws in connection with the use may be cause for revocation of this Coastal Development Permit. 01-25-19 Zoning Administrator Resolution No. ZA2019-056 Page 4 of 7 PASSED, APPROVED, AND ADOPTED THIS 15TH DAY OF AUGUST, 2019. Zoning Administrator Resolution No. ZA2019-056 Page 3 of 7 21.30A.040 (Determination of Public Access/Recreation Impacts) requires that the provision of public access bear a reasonable relationship between the requirement and the project’s impact and be proportional to the impact. In this case, the project demolishes an existing single-family dwelling and installs open landscape. The project includes the demolition of the existing single-family dwelling and the improvement of a private lawn. Therefore, the project does not involve a change in land use, density or intensity that will result in increased demand on public access and recreation opportunities. 2.The residential lot does not currently provide nor does it inhibit public coastal access. Development will occur within the confines of private property and existing coastal access conditions will not be affected. Coastal access is currently provided and will continue to be provided by small public beach areas on Lido Isle with access from the water. 3.The project site is not located adjacent to a coastal view road nor is it located near any public viewpoint as identified in the Coastal Land Use Plan. Furthermore, an investigation of the project site and surrounding area did not identify any other public view opportunities. The project site may be located within the viewshed of distant public viewing areas; however, the project will replace an existing single-family residence with a new, open, landscaped area. Therefore, the project does not have the potential to degrade the visual quality of the Coastal Zone or result in significant adverse impacts to public views. SECTION 4. DECISION. NOW, THEREFORE, BE IT RESOLVED: 1.The Zoning Administrator of the City of Newport Beach hereby finds this Project exempt from the California Environmental Quality Act pursuant to Section 15301 under Class 1 (Existing Facilities) of the CEQA Guidelines, California Code of Regulations, Title 14, Division 6, Chapter 3, because it has no potential to have a significant effect on the environment. 2. 3. The Zoning Administrator of the City of Newport Beach hereby approves Coastal Development Permit No. CD2018-111 subject to the conditions set forth in Exhibit “A,” which is attached hereto and incorporated by reference. This action shall become final and effective 14 days following the date this Resolution was adopted unless within such time an appeal or call for review is filed with the Community Development Director in accordance with the provisions of Title 21 Local Coastal Implementation Plan, of the Newport Beach Municipal Code. Final action taken by the City may be appealed to the Coastal Commission in compliance with Section 21.64.035 of the City’s certified LCP and Title 14 California Code of Regulations, Sections 13111 through 13120, and Section 30603 of the Coastal Act. 01-25-19 Zoning Administrator Resolution No. ZA2019-056 Page 2 of 7 SECTION 3. REQUIRED FINDINGS. In accordance with Section 21.52.015 (Coastal Development Permits) of the Newport Beach Municipal Code, the following findings and facts in support of such findings are set forth: Finding: A. Conforms to all applicable sections of the certified Local Coastal Program. Facts in Support of Finding: 1.The subject property is currently developed with a single-family dwelling on an existing lot designated for residential development by the Local Coastal Program. The project applicant requests to demolish the existing single-family dwelling. After the demolition of the existing dwelling, the site will be landscaped for private enjoyment. Per Section 21.30.085 of the Local Coastal Program, landscaping has been conditioned to have low- water demand and be drought-tolerant. The planting of invasive species shall be prohibited. Any subsequent construction will require a separate coastal development permit at a later date. 2. 3. The property is located in an area known for the potential of seismic activity and liquefaction. All projects are required to comply with the California Building Code and Building Division standards and policies. A Construction Pollution Prevention Plan was provided to implement temporary Best Management Practices (BMPs) during construction to minimize erosion and sedimentation and to minimize pollution of runoff and coastal waters derived by construction chemicals and materials. 4.The property is located within 100 feet of coastal waters. As conditioned, the project design will address water quality through the preparation of a final construction drainage system that includes drainage and percolation features designed to retain dry weather and minor rain event run-off on-site. Any water not retained on-site shall be directed to the City’s storm drain system. Finding: B.Conforms with the public access and public recreation policies of Chapter 3 of the Coastal Act if the project is located between the nearest public road and the sea or shoreline of any body of water located within the coastal zone. Facts in Support of Finding: 1.The project site is located on Lido Isle between the nearest public road and the sea or shoreline; however the project will not affect the public’s ability to gain access to, use, and/or view the coast and nearby recreational facilities. Implementation Plan Section 01-25-19 RESOLUTION NO. ZA2019-056 A RESOLUTION OF THE ZONING ADMINISTRATOR OF THE CITY OF NEWPORT BEACH APPROVING COASTAL DEVELOPMENT PERMIT NO. CD2018-111 TO DEMOLISH AN EXISTING SINGLE-FAMILY RESIDENCE AND INSTALL LANDSCAPING LOCATED AT 944 VIA LIDO NORD (PA2018-279) THE ZONING ADMINISTRATOR OF THE CITY OF NEWPORT BEACH HEREBY FINDS AS FOLLOWS: SECTION 1. STATEMENT OF FACTS. 1. 2. An application was filed by W.T. Durant, Inc., with respect to property located at 944 Via Lido Nord, and legally described as Lot 324 of Track 907, requesting approval of a coastal development permit. The applicant proposes the demolition of an existing 4,939-square-foot single-family residence and the improvement of a private lawn area for the same property owner located at 940 Via Lido Nord. The new improvements consist of the installation of approximately 4,027 square feet of new, open, landscaped and hardscaped areas which will be used by the owner for personal recreation and enjoyment. The existing property line walls, the existing cantilevered patio, the existing dock, and the existing bulkhead will not be demolished and will be left in their current locations. 3. 4. 5. The subject property is located within the Single-Unit Residential (R-1) Zoning District and the General Plan Land Use Element category is Single-Unit Residential Detached (RS-D). The subject property is located within the coastal zone. The Coastal Land Use Plan category is Single-Unit Residential Detached – (10.0-19.9 DU/AC) (RSD-C) and the Coastal Zoning District is Single-Unit Residential (R-1). A public hearing was held on August 15, 2019 in the Corona del Mar Conference Room (Bay E-1st Floor) at 100 Civic Center Drive, Newport Beach. A notice of time, place and purpose of the hearing was given in accordance with the Newport Beach Municipal Code. Evidence, both written and oral, was presented to, and considered by, the Zoning Administrator at this hearing. SECTION 2. CALIFORNIA ENVIRONMENTAL QUALITY ACT DETERMINATION. 1.This Project is categorically exempt from the California Environmental Quality Act (“CEQA”) pursuant to Section 15301 under Class 1 (Existing Facilities) of the CEQA Guidelines, California Code of Regulations, Title 14, Division 6, Chapter 3, because it has no potential to have a significant effect on the environment. 2.Class 1 includes the demolition and removal of small structures including one single- family dwelling. The proposed project includes the demolition of an existing single-family dwelling located in the R-1 Coastal Zoning District. PLOT DATE: SCALE: DESIGN BY: DRAWN BY: CHECKED DATE: FILE NAME: SH E E T S : REVISIONS: BILL DURANT Th e 9 4 4 V i a L i d o N o r d T r u s t 94 4 V i a L i d o N o r d Ne w p o r t B e a c h , C A 9 2 6 6 3 P 562.424.8816 F 562.424.8440 STAMP: BI L L D U R A N T De s i g n e r / B u i l d e r 22 5 9 O r a n g e A v e n u e Si g n a l H i l l , C a l i f o r n i a 9 0 7 5 5 AS NOTED Z: \ P r o j e c t F o l d e r s \ P r o j e c t s - 2 0 1 8 \ 9 4 4 V i a L i d o N o r d T r u s t \ 3 - P l o t S h e e t s \ G N G e n e r a l N o t e s . d w g GN General Notes BI L L D U R A N T De s i g n e r / B u i l d e r 22 5 9 O r a n g e A v e n u e Si g n a l H i l l , C a l i f o r n i a 9 0 7 5 5 July 24, 2020 RM / KC AS NOTED Z: \ P r o j e c t F o l d e r s \ P r o j e c t s - 2 0 1 8 \ 9 4 4 V i a L i d o N o r d T r u s t \ 3 - P l o t S h e e t s \ G N G e n e r a l N o t e s . d w g GN General Notes 1 GN.8FIRE SEPARATION Fire Separation 1/8" = 1'-0"GN.7 1 1/2" MIN. GYPSUM WALLBOARD APPLIED VERTICALLY OR HORIZONTALLY NAILED WITH 6d COOLER OR WALLBOARD NAILS AT 7" O.C. WITH END JOINTS ON NAILING MEMBERS. STAGGER JOINTS EACH SIDE. MINIMUM 2 X 4 WOOD STUDS AT 24" O.C. MAXIMUM. MINERAL/GLASS FIBER BATT INSULATION NON-RATED PENETRATION ALLOWED ON THIS SIDE NON-RATED FINISH MATERIAL. HEAVY TIMBER MINIMUM 2X4 WOOD STUDS AT 16" O.C. MAXIMUM 7/8" EXTERIOR CEMENT PLASTER (MEASURED FROM THE FACE OF STUDS) ON THE EXTERIOR SURFACE PLASTER MIX 1:4 FOR SCRATCH COAT 1:5 FOR BROWN COAT, BY VOLUME, CEMENT TO SAND. OVER METAL LATH OVER BUILDING PAPER. 1/2" GYPSUM WALLBOARD APPLIED VERTICALLY OR HORIZONTALLY NAILED WITH 6d COOLER OR WALLBOARD NAILS AT 7" O.C. WITH END JOINTS ON NAILING MEMBERS. STAGGER JOINTS EACH SIDE. MINIMUM 2X4 WOOD STUDS AT 16" O.C. MAXIMUM ALL NON-FIRE RATED FINISH MATERIALS 5/8" GYPSUM SHEATHING (EXTERIOR EXPOSURE) NAILED WITH1-3/4" BY NO.11 GAUGE BY 7/16" HEAD GALVANIZED NAILS AT 8" O.C. FINISH MATERIALS NAILED WITH MINIMUM 7d GALVANIZED SMOOTH BOX NAILS. (VERIFY WITH MATERIAL MANUFACTURER) OVER BUILDING PAPER 1/2" GYPSUM WALLBOARD OR SHEATHING APPLIED VERTICALLY OR HORIZONTALLY NAILED WITH 6d COOLER OR WALLBOARD NAILS AT 7" O.C. WITH END JOINTS ON NAILING MEMBERS. STAGGER JOINTS EACH SIDE. FIRE PROTECTION R-3 OCCUPANCY (DWELLING) TO U OCCUPANCY (PRIVATE GARAGE) OCCUPANCY SEPARATION NOTES: OCCUPANCY SEPARATION SHALL BE VERTICAL OR HORIZONTAL OR BOTH WHEN NECESSARY OF SUCH OTHER FORM AS MAY BE REQUIRED TO AFFORD A COMPLETE SEPARATION BETWEEN THE VARIOUS OCCUPANCY DIVISIONS IN THE BUILDING. THE INFORMATION SHOWN HERE IS INTENDED TO ILLUSTRATE THE “GENERAL” FIRE PROTECTION REQUIREMENTS FOR R-3 OCC. TO U OCC. OCCUPANCY SEPARATION AND THE MINIMUM APPLICABLE CRC REQUIREMENTS. REFER TO CBC FOR DETAILED REQUIREMENTS. ALL FIELD CONDITIONS WHICH MAY POSSIBLY BE ENCOUNTERED ARE NOT NECESSARILY DESCRIBED. FIELD CONDITIONS ENCOUNTERED WHICH REQUIRE CLARIFICATION SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT IN A TIMELY MANNER. THE ARCHITECT RECOMMENDS THAT ALL TRADES PERFORMING WORK AT FIRE PROTECTION AREAS BE FULLY KNOWLEDGEABLE OF THE CODE REQUIREMENTS FOR THE MATERIALS AND INSTALLATION. FURTHER, IT IS RECOMMENDED THAT THE GENERAL CONTRACTOR FIELD-WALK THE ENTIRE LENGTH AND EXTENT OF THE FIRE-PROTECTED AREAS WITH THE BUILDING OFFICIAL DURING THE MODEL UNIT CONSTRUCTION TO INSURE THAT ALL MATERIALS, INSTALLATION, PENETRATIONS, CONNECTIONS, ETC. ARE COMPLETE AND IN ACCORDANCE WITH ALL CODE REQUIREMENTS. ALL “GENERAL“ REQUIREMENTS SHOWN SHALL BE VERIFIED WITH LOCAL ORDINANCES AND REQUIREMENTS, THE MORE STRINGENT SHALL PREVAIL.. DWELLING UNIT AND IT’S ATTIC AREA SHALL BE SEPARATED BY MEANS OF A MINIMUM 1/2 INCH GYPSUM BOARD APPLIED TO THE GARAGE SIDE. GARAGES BENEATH HABITABLE ROOMS SHALL BE SEPARATED FROM ALL HABITABLE ROOMS ABOVE BY NOT LESS THAN A 5/8 INCH TYPE X GYPSUM BOARD OR EQUIVALENT. DOOR OPENINGS BETWEEN A PRIVATE GARAGE IN THE DWELLING UNIT SHALL BE EQUIPPED WITH EITHER SOLID WOOD DOORS OR SOLID OR HONEYCOMB CORE STEEL DOORS NOT LESS THAN 1 3/8 INCHES THICK, OR DOORS IN COMPLIANCE WITH SECTION OR 302.5. OPENINGS FROM A PRIVATE GARAGE DIRECTLY INTO A ROOM USED FOR SLEEPING PURPOSES SHALL NOT BE PERMITTED. DOORS SHALL BE SELF-CLOSING AND SELF-LATCHING (CRC SEC. R302.5). APPLICABLE NOTES TO DETAILS: A) REFER TO SPECIFIC FIRE ASSEMBLIES FROM CRC FOR ALL ADDITIONAL FOOTNOTES, SPECIAL REQUIREMENTS, AND PROPRIETARY MATERIALS. B) STRUCTURAL DRAWINGS SHALL BE REFERENCED TO STRUCTURALLY REQUIRED SHEATHING THICKNESSES, MEMBER SIZING, AND SPACING BEYOND THE PROTECTION MINIMUMS NOTED HERE. CONFLICTING INFORMATION SHOULD BE BROUGHT TO THE ATTENTION OF THE ARCHITECT IN A TIMELY MANNER. SELF-CLOSING, SELF-LATCHING, SOLID WOOD OR METAL HONEYCOMB, 1-3/8 INCHES IN THICKNESS (OR SELF-CLOSING SELF-LATCHING DOOR HAVING A FIRE PROTECTION RATING OF NOT LESS THAN 20 MINUTES. DUCTS IN A PRIVATE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING UNIT FROM THE GARAGE SHALL BE CONSTRUCTED OF A MINIMUM 0.019-INCH (0.48 MM) SHEET METAL AND SHALL HAVE NO OPENINGS INTO THE GARAGE. MECHANICAL PENETRATION CRC R302.5.2 DOOR HOUSE TO GARAGE DOOR CRC R302.5 WALL BETWEEN GARAGE AND DWELLING INTERIOR WALL CRC R302.6 WALLS THAT SUPPORT OCCUPANCY SEPARATION WALLS THAT SUPPORT THE STRUCTURE OF OCCUPANCY ABOVE CBC 706.5 4.1 EXTERIOR WALL CRC R302.6 4.2 EXTERIOR WALL AT SIDING CRC R302.6 ISOLATED POST THAT SUPPORTS OCCUPANCY SEPARATION ISOLATED POST THAT SUPPORTS THE STRUCTURE OF OCCUPANCY ABOVE CBC 706.5 5.1 ISOLATED POST 1-HR FIRE-RESISTIVE CONSTRUCTION CRC R302.6 5.2 ISOLATED POST 1 HR FIRE-RESISTIVE CONSTRUCTION CRC R327.2 & R327.7 6.1 FLOOR/CEILING REQ'D FIRE BARRIER R302.6 6.2 ROOF/CEILING CRC R302.6 NON-RATED BEAMS AND GIRDERS MAY BE OF SAWN TIMBER OR STRUCTURAL GLUE-LAMINATED TIMBER AND SHALL NOT BE LESS THAN 6 INCHES IN WIDTH AND NOT LESS THAN 10 INCHES IN DEPTH (NOMINAL) IF NO HABITABLE SPACE DIRECTLY ABOVE: 1/2" GYPSUM WALLBOARD NAILED TO JOIST W/5d COOLER OR WALL BOARD NAILS AT 6" O.C. END JOINTS OF WALLBOARD CENTERED ON JOISTS. WOOD JOIST, GYPSUM WALLBOARD ONE LAYER OF 5/8" TYPE X GYPSUM WALLBOARD OR GYPSUM VENEER BASE SHALL BE INSTALLED PERPENDICULAR TO THE CEILING FRAMING AND SHALL BE FASTENED AT MAXIMUM 6 INCHES O.C. BY MIN. 1-*7/8" 6d COATED NAILS OR EQUIVALENT DRYWALL SCREWS. SUPPORT POST LES THAN 8X8 (NOMINAL) 1/2" GYPSUM WALLBOARD APPLIED VERTICALLY OR HORIZONTALLY NAILED WITH 6d COOLER OR WALLBOARD NAILS AT 7" O.C. WITH END JOINTS ON NAILING MEMBERS. STAGGER JOINTS EACH SIDE. 22-GA. STEEL JACKET AROUND COLUMN OR CORNER GUARDS FOR IMPACT PROTECTION NOT LESS THAN 5 FT. ABOVE F.F. SUPPORT POST NOT LESS THAN 8X8 (NOMINAL) NO ADDITIONAL PROTECTED REQUIRED NOTES: 1.FOAM PLASTIC INSULATION SHALL COMPLY WITH SECTION R316.5. 2.DRAFTSTOPS SHALL BE INSTALLED WHEN THERE IS USABLE SPACE BOTH ABOVE AND BELOW THE CONCEALED SPACE OF A FLOOR/CEILING ASSEMBLY, SO THAT THE AREA OF CONCEALED SPACE DOES NOT EXCEED 1000 SQUARE FEET AND IS DIVIDED INTO APPROXIMATELY EQUAL AREAS. DRAFTSTOPPING MATERIAL SHALL BE AS SPECIFIED IN SECTION R302.12. 3.FIREBLOCKING SHALL BE PROVIDED IN ACCORDANCE WITH SECTION R302.11: a.IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES AND PARALLEL ROWS OF STUDS OR STAGGERED STUDS AT THE CEILING AND FLOOR LEVEL, AND AT MAXIMUM 10-FOOT HORIZONTAL INTERVALS. BATTS OR BLANKETS OF MINERAL OR GLASS FIBER OR OTHER APPROVED NONRIGID MATERIALS SHALL BE PERMITTED FOR COMPLIANCE WITH THE 10-FOOT HORIZONTAL FIREBLOCKING IN WALLS CONSTRUCTED USING PARALLEL ROWS OF STUDS OR STAGGERED STUDS b.AT ALL INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND HORIZONTAL SPACES SUCH AS OCCUR AT SOFFITS, DROP CEILINGS AND COVE CEILINGS. c.IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM OF THE RUN. d.AT OPENINGS AROUND VENTS, PIPES, DUCTS, CABLES AND WIRES AT CEILING AND FLOOR LEVEL, WITH AN APPROVED MATERIAL TO RESIST THE FREE PASSAGE OF FLAME AND PRODUCTS OF COMBUSTION. FOR THE FIREBLOCKING OF CHIMNEYS AND FIREPLACES, SEE SECTION R1003.19. 4.FIREBLOCKING MATERIALS SHALL CONSIST OF ONE OF THE FOLLOWING (R302.11.1): a.2-INCH NOMINAL LUMBER. b.TWO THICKNESSES OF 1-INCH NOMINAL LUMBER WITH BROKEN LAP JOINTS. c.ONE THICKNESS OF 23/32INCH WOOD STRUCTURAL PANELS WITH JOINTS BACKED BY 23/32 INCH WOOD STRUCTURAL PANELS. d.ONE THICKNESS OF 3/4-INCH PARTICLE BOARD WITH JOINTS BACKED BY ¾ INCH PARTICLE BOARD, 1/2 INCH GYPSUM BOARD OR 1/4 INCH CEMENT-BASED MILLBOARD. e.BATTS OR BLANKETS OF MINERAL WOOL OR GLASS FIBER OR OTHER APPROVED MATERIALS INSTALLED IN SUCH A MANNER AS TO BE SECURELY RETAINED IN PLACE. SEPARATION FIRE/OCCUPANCY PLOT DATE: SCALE: DESIGN BY: DRAWN BY: CHECKED DATE: FILE NAME: SH E E T S : REVISIONS: BILL DURANT Th e 9 4 4 V i a L i d o N o r d T r u s t 94 4 V i a L i d o N o r d Ne w p o r t B e a c h , C A 9 2 6 6 3 P 562.424.8816 F 562.424.8440 STAMP: BI L L D U R A N T De s i g n e r / B u i l d e r 22 5 9 O r a n g e A v e n u e Si g n a l H i l l , C a l i f o r n i a 9 0 7 5 5 AS NOTED Z: \ P r o j e c t F o l d e r s \ P r o j e c t s - 2 0 1 8 \ 9 4 4 V i a L i d o N o r d T r u s t \ 3 - P l o t S h e e t s \ G N G e n e r a l N o t e s . d w g GN General Notes BI L L D U R A N T De s i g n e r / B u i l d e r 22 5 9 O r a n g e A v e n u e Si g n a l H i l l , C a l i f o r n i a 9 0 7 5 5 July 24, 2020 RM / KC AS NOTED Z: \ P r o j e c t F o l d e r s \ P r o j e c t s - 2 0 1 8 \ 9 4 4 V i a L i d o N o r d T r u s t \ 3 - P l o t S h e e t s \ G N G e n e r a l N o t e s . d w g GN General Notes 48" 36 "30" 36 " COVERED LOGGIA COVERED PATIO 944 VIA LIDO NORD NEW 2-STORY SINGLE FAMILY RESIDENCE WITH ATTACHED GARAGE TYP.TYP. 9'-0 7/8" ±22'-2"90'-3 1/4"± 14'-10 3/4" 10'-6 1/2"± TO BULKHEAD76'-2"21'-3 1/4" 31 ' - 7 " 4' - 0 " 4' - 4 " ± 5 3 / 4 " 3' - 7 3 / 8 " 8' - 2 3 / 4 " 3' - 6 " 23 ' - 6 " ± 4' - 4 7 / 8 " ± 31'-11 1/4"± 7 1/4"± 28 ' - 9 3 / 4 " EX I S T I N G D R I V E W A Y A P P R O A C H T O R E M A I N ARTIFICIAL TURF CONCRETE EXISTING WALKWAY LINE OF WALL ABOVE LINE OF STRUCTURE ABOVE 12'-2 3/4" 30 ' - 0 " 10'-2" ± TO BULKHEAD 2.5" ARTIFICIAL TURF 20'X20' CLR. EXISTING DRIVEWAY EXISTING DRIVEWAY SLOPED TO DRAIN CONCRETE CONCRETE 1.00 1.05 1.08 1.04 1.05 1.05 1.04 1.04 1.05 1.14 1.15 1.19 1.00 1.12 1.04 1.13 1.10 1.24 1.16 2.00 1.20 1.17 1.02 TYP. TYP. TYP. TYP. 1.23 TYP. 1.03 1.03 1.06 TYP. 1.01 1.18 TYP. ARTIFICIAL TURF ARTIFICIAL TURF 2.01 2.02 2.01 2.01 2.01 2.042.06 2.09 2.09 2.08 2.07 2.05 1.05 TYP.1.05 TYP. PR O P E R T Y L I N E P R O P E R T Y L I N E PROPERTY LINE PROPERTY LINE L= 4 6 . 0 0 ' R= 3 8 3 . 1 0 ' = 6 ° 5 2 ' 4 7 " L = 4 0 . 0 0 ' R = 2 4 1 . 7 7 ' = 9 ° 2 8 ' 4 5 " 127.02'N 58°11'08" W 134.97' N 60°57'33" W NOR T H 12 . 4 9 ' T C 12 . 6 2 ' T C 10.4 8 ' F S 12. 7 4 ' F G NE I G H B O R I N G B U L K H E A D V I A L I D O N O R D EX I S T I N G B U L K H E A D NE I G H B O R I N G B U L K H E A D 12 . 0 1 ' F G 12.5 0 ' F G LOT AREA: MAX. TOTAL FLOOR AREA CITYWIDE (BUILDABLE x2): BUILDABLE AREA: CONDITIONED FLOOR AREA TOTAL CONDITIONED FLOOR AREA: UNCONDITIONED AREA GARAGE: COVERED PATIO: REQUIRED OPEN VOLUME AREA (BUILDABLE X15%): PROVIDED OPEN VOLUME AREA: SECOND FLOOR CONDITIONED: SECOND FLOOR BALCONY: 5600 SQ. FT. 4046 SQ. FT. 8092 SQ. FT. 888 SQ. FT. 190 SQ. FT. 606.90 SQ. FT. 3487 SQ. FT. 551 SQ. FT. 658 SQ. FT. PROPOSED FLOOR AREA GARAGE:658 SQ. FT. TOTAL FLOOR AREA:1209 SQ. FT. SECOND FLOOR COVERED DECK:73 SQ. FT. 551 SQ. FT. EXTERIOR STAIRS 76 SQ. FT. SECOND FLOOR CONDITIONED:551 SQ. FT. EXISTING DOCK TO BE REPAIRED 462 SQ. FT. SITE PLAN A1.1 PROPOSED SITE PLAN SCALE: 1/8" = 1'-0"1 PLOT DATE: SCALE: DESIGN BY: DRAWN BY: CHECKED DATE: FILE NAME: SH E E T S : REVISIONS: BILL DURANT Th e 9 4 4 V i a L i d o N o r d T r u s t 94 4 V i a L i d o N o r d Ne w p o r t B e a c h , C A 9 2 6 6 3 P 562.424.8816 F 562.424.8440 STAMP: BI L L D U R A N T De s i g n e r / B u i l d e r 22 5 9 O r a n g e A v e n u e Si g n a l H i l l , C a l i f o r n i a 9 0 7 5 5 AS NOTED Z: \ P r o j e c t F o l d e r s \ P r o j e c t s - 2 0 1 8 \ 9 4 4 V i a L i d o N o r d T r u s t \ 3 - P l o t S h e e t s \ A 1 . 1 P r o p o s e d S i t e P l a n . d w g A1.1 Proposed Site Plan BI L L D U R A N T De s i g n e r / B u i l d e r 22 5 9 O r a n g e A v e n u e Si g n a l H i l l , C a l i f o r n i a 9 0 7 5 5 July 24, 2020 RM / KC AS NOTED Z: \ P r o j e c t F o l d e r s \ P r o j e c t s - 2 0 1 8 \ 9 4 4 V i a L i d o N o r d T r u s t \ 3 - P l o t S h e e t s \ A 1 . 1 P r o p o s e d S i t e P l a n . d w g A1.1 Proposed Site Plan (E) SITE KEYNOTES SITE PLAN LEGEND(N) SITE KEYNOTES SQUARE FOOTAGE -PROPERTY LINE -EXISTING 72" STUCCO WALL TO REMAIN -2-STORY SINGLE FAMILY RESIDENCE -CONCRETE -6 FT. GATE -6 FT. STUCCO BLOCK WALL, NOTE: MAXIMUM OF FT. MEASURED FROM EXISTING GRADE - 2.00 2.01 2.02 2.03 2.04 - - - NEIGHBORING RESIDENCE TO REMAIN1.00 1.01 1.02 -SETBACK - - - 2.05 2.06 2.07 GAS METER DECK ABOVE BULKHEAD -1.03 PROPERTY LINE ELECTRICAL SERVICE METER -2.08 -1.04 SETBACK-1.05 CONCRETE DRIVEWAY TO REMAIN-1.06 STUCCO BLOCK WALL TO BE REMOVED-1.07 72" WHITE STUCCO PROPERTY WALL TO REMAIN-1.08 NOT USED-1.09 WATER METER TO REMAIN-1.10 NOT USED-1.11 WOOD DECK TO BE REPAIRED, (SEPARATE PERMIT)-1.12 BAY-1.13 STREET CURB TO REMAIN-1.14 FLOWLINE TO REMAIN-1.15 CONCRETE CURB-CUT TO REMAIN -1.16 -2.09 BULKHEAD TO REMAIN SANDY BEACH BELOW TO REMAIN PIERS UNDER DECK TO REMAIN -1.17 LIGHT POLE TO REMAIN ARTIFICIAL TURF- CONCRETE- LINE OF WALL ABOVE LINE OF BALCONY ABOVE CONCRETE WALKWAY TO REMAIN-1.18 WATER VALVE TO REMAIN-1.19 -1.20 6" CAST IRON PIPE TO REMAIN -1.21 NOT USED ARTIFICIAL TURF TO REMAIN-1.22 NEIGHBORING BULKHEAD TO REMAIN-1.23 -1.24 DOCK TO BE REPAIRED (SEPARATE PERMIT) TRASH BIN WOOD DECK- PROPOSED PR O P E R T Y L I N E P R O P E R T Y L I N E PROPERTY LINE PROPERTY LINE L= 4 6 . 0 0 ' R= 3 8 3 . 1 0 ' = 6 ° 5 2 ' 4 7 " L= 4 0 . 0 0 ' R = 2 4 1 . 7 7 ' = 9 ° 2 8 ' 4 5 " 127.02'N 58°11'08" W 134.97' N 60°57'33" W NOR T H 12. 4 9 ' T C 12.6 2 ' T C 10.4 8 ' F S 12 . 7 4 ' F G 4'-0" PUBLIC UTILITY EASEMENT/ SETBACK 4'- 0 " SE T B A C K 10'-0" WATER SIDE SETBACK 4' - 0 " SE T B A C K NE I G H B O R I N G B U L K H E A D V I A L I D O N O R D EX I S T I N G B U L K H E A D SE T B A C K SETBACK SE T B A C K SETBACK NE I G H B O R I N G B U L K H E A D 12 . 0 1 ' F G 12 . 5 0 ' F G BULKHEAD SETBACK 98'-4" 10'-6"± (10'-0" MIN. FROM BUILDING TO BULKHEAD PER CITY) 97'-3 7/8" 42'-11 1/8"54'-4 3/4" 20'-0" 1'-7" 22'-1 1/4" 6 1/8" 76'-2 3/4" 31 ' - 8 3 / 4 " 7" 7" 22'-2"22'-2"22'-2"9'-8 1/2" COVERED PATIO 2-CAR GARAGE 31 ' - 8 3 / 4 " 23 ' - 6 3 / 4 " 8'- 2 " 8'- 2 " 20'-0" 4'- 0 5 / 8 " 4' - 0 5 / 8 " 7" 36'-9 1/2"± FSD SLOPE 1% TO DRAIN 48" 36 " LINE OF STRUCTURE ABOVE LINE OF STRUCTURE ABOVE LINE OF BALCONY ABOVE LINE OF STRUCTURE BELOW 30" 36 " SLOPE 2% TO DRAIN 30 ' - 6 3 / 4 " 1' - 5 3 / 8 " ARTIFICIAL TURF CONCRETE WALKWAY TWH 10'-2"± TO BULKHEAD3'- 6 " 7" 20 ' - 0 3 / 4 " 26'-4 11/128"11'-2 37/64" 4' - 0 3 / 4 " 4'-1 1/2"25'-4 1/4" 5' - 2 1 / 2 " 18 ' - 7 3 / 8 " LINE OF BALCONY ABOVE ARTIFICIAL TURF ARTIFICIAL TURF ARTIFICIAL TURF TYP. 1.01 TYP. 1.23 1.20 1.13 1.141.19 1.18 1.22 TYP. 1.21 1.22 1.021.02 1.021.01 1.24 1.241.24 1'-7 3/4" 1' - 1 1 1 / 2 " UP 21R @ 7.68"/R 3'-0"8'-4"3'-0"7'-6" 3'- 6 " 4" CONC. SLAB LINE OF STRUCTURE ABOVE LINE OF STRUCTURE ABOVE 1.04 1.05 SLOPE 1% TO DRAIN28 ' - 1 0 " 28 ' - 9 3 / 4 " EX I S T I N G D R I V E W A Y A P P R O A C H T O R E M A I N 2.5" 20'X20' CLR. EXISTING DRIVEWAY EXISTING DRIVEWAY CONCRETE CONCRETE PLOT DATE: SCALE: DESIGN BY: DRAWN BY: CHECKED DATE: FILE NAME: SH E E T S : REVISIONS: BILL DURANT Th e 9 4 4 V i a L i d o N o r d T r u s t 94 4 V i a L i d o N o r d Ne w p o r t B e a c h , C A 9 2 6 6 3 P 562.424.8816 F 562.424.8440 STAMP: BI L L D U R A N T De s i g n e r / B u i l d e r 22 5 9 O r a n g e A v e n u e Si g n a l H i l l , C a l i f o r n i a 9 0 7 5 5 AS NOTED Z: \ P r o j e c t F o l d e r s \ P r o j e c t s - 2 0 1 8 \ 9 4 4 V i a L i d o N o r d T r u s t \ 3 - P l o t S h e e t s \ A 2 . 1 F i r s t F l o o r P l a n . d w g A2.1 First Floor Plan BI L L D U R A N T De s i g n e r / B u i l d e r 22 5 9 O r a n g e A v e n u e Si g n a l H i l l , C a l i f o r n i a 9 0 7 5 5 July 24, 2020 RM / KC AS NOTED Z: \ P r o j e c t F o l d e r s \ P r o j e c t s - 2 0 1 8 \ 9 4 4 V i a L i d o N o r d T r u s t \ 3 - P l o t S h e e t s \ A 2 . 1 F i r s t F l o o r P l a n . d w g A2.1 First Floor Plan FIRST FLOOR PLAN A2.1 FIRST FLOOR PLAN SCALE: 1/4" = 1'-0"1 WALL LEGEND: NEW 2X4 WALLS NEW 2X6 WALLS FLOOR PLAN KEYNOTES: 1.00 PLAN NOTES: SYMBOL LEGEND: * - ELEVATION / SECTION CALLOUT - KEYNOTE - DETAIL CALLOUT - INTERIOR ELEVATION CALLOUT - DOOR CALLOUT - WINDOW CALLOUT - EGRESS WINDOW 1 AD.1 1 A3.0 1 A5.0 A B C D 1.00 A 1 - SIZE / TYPE SIZE / TYPE - NEW DOOR - EXISTING DOOR - NEW WINDOW - EXIST. WINDOW - REFER TO EXIST. - PLAN FOR SIZE - REFER TO EXIST. - PLAN FOR SIZE - TEMPERED GLASS 1.01 1.02 SINGLE 2x4 STUD FRAMED WALL WINDOW DOOR1.03 1.04 1.05 1.06 1.07 1.08 1.09 1.10 1.11 1.12 1.13 1.18 1.19 SHELF AND POLE NOT USED SINK W/ GARBAGE DISPOSAL 1.14 1.15 1.16 1.17 SINGLE 2x6 STUD FRAMED WALL LOWER CABINETS 30" COOK TOP 30" REFRIGERATOR 1.20 1.21 1.22 1.23 1.24 SHOWER WATER CLOSET LAVATORY SINK DRYER METAL STAIRS W/ 36" CABLE HANDRAILS CABLE STAIR RAILING WASHER TANKLESS WATER HEATER ELECTRICAL SERVICE PANEL GAS METER - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ALL BEDROOMS, BASEMENTS OR ROOMS USED FOR SLEEPING SHALL HAVE EMERGENCY RESCUE WINDOWS OR DOORS. A.MIN. NET CLEAR OPENING OF 5.7 SQ. FT. B.MIN. NET CLEAR OPENING WIDTH OF 20". C.MIN. NET CLEAR HEIGHT OF 24". D.WINDOW SILL HEIGHT OF NOT MORE THAN 44" ABOVE THE FLOOR. 1.ALL WORK PERFORMED ON THIS PROJECT SHALL BE IN CONFORMANCE WITH THESE PLANS AND THE STANDARDS SET BY THE LOCAL BUILDING OFFICIAL. 2.SMOKE DETECTORS SHALL BE INTERCONNECTED TO SOUND AN ALARM IN ALL SLEEPING AREAS OF THE DWELLING; BE INSTALLED IN EACH SLEEPING ROOM AND IN THE CORRIDOR OR AREA GIVING ACCESS TO EACH SEPARATE SLEEPING AREA AND BE EQUIPPED WITH A BATTERY BACKUP AS PER CBC SECTION 310.9.1. 3.PROVIDE COMBUSTION AIR TO FORCED AIR UNIT PER CMC SECTION 318 AND TO WATER HEATER PER CPC SECTION 507.3. 4.DOMESTIC DRYER MOISTURE EXHAUST DUCTS SHALL COMPLY WITH CMC SECTION 504.3. 5.ALL DIMENSIONS ARE TO FACE OF STUD OR CONCRETE UNLESS NOTED OTHERWISE. 6.EXHAUST FANS REQUIRED IN BATH AND/OR LAUNDRY ROOMS MUST CONNECT DIRECTLY TO THE OUTSIDE AND MUST PROVIDE 5 AIR CHANGES PER HOUR. CBC SECTION 1203.3. 7.REFER TO DOOR AND WINDOW SCHEDULE FOR ADDITIONAL INFORMATION 8.WATER HEATERS SHALL BE ANCHORED OR STRAPPED TO RESIST HORIZONTAL MOVEMENT IN ACCORDANCE WITH CPC SECTION 510.5. 9.WALL COVERING OF SHOWERS OR TUBS WITHIN SHOWERS SHALL BE OF A CEMENT PLASTER, TILE, OR APPROVED EQUAL, TO A HEIGHT OF NOT LESS THAN 72" ABOVE DRAIN INLET. CEMENT PLASTER BACKING TO BE PROVIDED. 10.STUDS SUPPORTING TWO FLOORS, CEILING, AND ROOF MUST BE 3X4 OR 2X6 AT 16" ON CENTER. CRC TABLE R602.3.(5) 11.EMERGENCY AND ESCAPE RESCUE OPENINGS SHALL HAVE A NET CLEAR OPENING OF NOT LESS THAN 5.7 SQUARE FEET (0.530 M2). THE NET CLEAR OPENING DIMENSIONS REQUIRED BY THIS SECTION SHALL BE OBTAINED BY THE NORMAL OPERATION OF THE EMERGENCY ESCAPE AND RESCUE OPENING FROM THE INSIDE. THE NET CLEAR HEIGHT OPENING SHALL BE NOT LESS THAN 24 INCHES (610 MM) AND THE NET CLEAR WIDTH SHALL BE NOT LESS THAN 20 INCHES (508 MM). EXCEPTION: GRADE FLOOR OR BELOW GRADE OPENINGS SHALL HAVE A NET CLEAR OPENING OF NOT LESS THAN 5 SQUARE FEET (0.465 M2). 12. WINDOW WELLS WITH A VERTICAL DEPTH GREATER THAN 44 INCHES (1118 MM) SHALL BE EQUIPPED WITH A PERMANENTLY AFFIXED LADDER OR STEPS USABLE WITH THE WINDOW IN THE FULLY OPEN POSITION. LADDERS OR STEPS REQUIRED BY THIS SECTION SHALL NOT BE REQUIRED TO COMPLY WITH SECTIONS R311.7 AND R311.8. LADDERS OR RUNGS SHALL HAVE AN INSIDE WIDTH OF NOT LESS THAN 12 INCHES (305 MM), SHALL PROJECT NOT LESS THAN 3 INCHES (76 MM) FROM THE WALL AND SHALL BE SPACED NOT MORE THAN 18 INCHES (457 MM) ON CENTER VERTICALLY FOR THE FULL HEIGHT OF THE WINDOW WELL. 13. GARAGE FLOOR SURFACES SHALL BE OF AN APPROVED NONCOMBUSTIBLE MATERIAL, AND THE AREA USED TO PARK VEHICLES SHALL BE SLOPED TO A DRAIN OR TOWARD THE MAIN VEHICLE ENTRY (R309.1). 14. GARAGES BENEATH HABITABLE ROOMS SHALL BE SEPARATED BY NO LESS THAN 58 INCH TYPE X GYPSUM BOARD APPLIED TO THE UNDERSIDE OF FLOOR FRAMING. PROVIDE MINIMUM 1 2 INCH GYPSUM BOARD ON THE GARAGE SIDES ELSEWHERE.SEE GN.7 15. CBC 708A.4 GARAGE DOOR PERIMETER GAP WEATHER STRIPPING. EXTERIOR GARAGE DOORS SHALL RESIST THE INTRUSION OF EMBERS FROM ENTERING BY PREVENTING GAPS BETWEEN DOORS AND DOOR OPENINGS, AT THE BOTTOM, SIDES AND TOPS OF DOORS, FROM EXCEEDING 1/8 INCH. GAPS BETWEEN DOORS AND DOOR OPENINGS SHALL BE CONTROLLED BY ONE OF THE METHODS LISTED IN THIS SECTION. TRASH BIN STRUCTURAL COLUMN, REFER TO STRUCTURAL PLANS 42" CABLE RAILING T 30'x18' SECTIONAL GARAGE DOOR 30'x18' ROLLUP GARAGE DOOR PR O P E R T Y L I N E P R O P E R T Y L I N E PROPERTY LINE PROPERTY LINE L= 4 6 . 0 0 ' R= 3 8 3 . 1 0 ' = 6 ° 5 2 ' 4 7 " L = 4 0 . 0 0 ' R = 2 4 1 . 7 7 ' = 9 ° 2 8 ' 4 5 " 127.02'N 58°11'08" W 134.97' N 60°57'33" W NOR T H 4'-0" PUBLIC UTILITY EASEMENT/ SETBACK 4' - 0 " SE T B A C K 10'-0" WATER SIDE SETBACK 4'- 0 " SE T B A C K NE I G H B O R I N G B U L K H E A D V I A L I D O N O R D EX I S T I N G B U L K H E A D SE T B A C K SETBACK SE T B A C K SETBACK NE I G H B O R I N G B U L K H E A D BULKHEAD SETBACK TYP. 1.01 1.23 1.23 1.25 1.25 1.021.02 1.021.01 TYP.1.01 TYP. 1.01 TYP. 1.021.02 1.02 1.02 1.03 1.06 TYP. 1.06 TYP. 1.03 31 ' - 8 3 / 4 " 98'-3" 76'-2" 1'-6 1/8" 98'-3" 22'-0 1/4" 1'-6 1/8"20'-0"6 1/8"10'-0"7" 8'-10 3/4" 31 ' - 8 3 / 4 " 7" 30 ' - 0 " 21'-9 1/8" 8'- 2 " 67'-4 1/8" 4' - 0 5 / 8 " 22'-1 1/8" 7" 6 1/8" 4' - 2 1 / 2 " ± 15'-4"± 1/4:12 TYP. 7" OPEN TO BELOW VAULTED BED 1 VAULTED BED 2 VAULTED KIT./ LIVING RM. VAULTED 20'-0"54'-4 3/4" @ 7.68"/R 6' - 1 1 " 7 3 / 4 " 3' - 6 " 11 ' - 8 " 3'-0"4'-0" 6'- 6 " 30 ' - 6 3 / 4 " 19 ' - 5 3 / 4 " 8'-0" 3' - 6 " 7' - 0 " BALCONY COVERED DECK 3 3 / 8 " 3 3 / 8 " 2'-0" 6 3/4"4 3/4" 20'-0" 6 3/4"6 3/4" 4'-0" 2'-0" 6 3/4"4 3/4" 2'-0"11'-2 1/2"10'-0" 4'-0" 3'-0"8'-4"3'-0"7'-6" 4'-0"4'-0"2'-0" CL O S E T SHOWER DW R S SHOWER DWRS DWRS BATH 1 VAULTED BATH 2 VAULTED CL O S E T 6'-8" @ T.O.PLATE 3'-0"4'-0" 1/ 4 : 1 2 T Y P . 7 1 / 4 " 7" 4 3 / 4 " 3'- 7 1 / 4 " 4 3 / 4 " 3'- 7 1 / 4 " 12'-0" 2' - 0 " DN 21R 1.03 1.03 1.03 1.03 1.03 1.03 1.02 1.02 1.02 1.02 1.02 1.15 1.151.16 1.161.071.07 1.06 1.081.17 1.17 1.09 1.01 TYP. 1.111.121.08 1.04 1.02 LINE OF ROOF ABOVE 1.00 TYP.1.00 TYP. 1 1 1 1 1 1 4 2A 2A 3 2B 2A 2A4 5 PLOT DATE: SCALE: DESIGN BY: DRAWN BY: CHECKED DATE: FILE NAME: SH E E T S : REVISIONS: BILL DURANT Th e 9 4 4 V i a L i d o N o r d T r u s t 94 4 V i a L i d o N o r d Ne w p o r t B e a c h , C A 9 2 6 6 3 P 562.424.8816 F 562.424.8440 STAMP: BI L L D U R A N T De s i g n e r / B u i l d e r 22 5 9 O r a n g e A v e n u e Si g n a l H i l l , C a l i f o r n i a 9 0 7 5 5 AS NOTED Z: \ P r o j e c t F o l d e r s \ P r o j e c t s - 2 0 1 8 \ 9 4 4 V i a L i d o N o r d T r u s t \ 3 - P l o t S h e e t s \ A 2 . 2 S e c o n d F l o o r P l a n . d w g A2.2 Second Floor Plan BI L L D U R A N T De s i g n e r / B u i l d e r 22 5 9 O r a n g e A v e n u e Si g n a l H i l l , C a l i f o r n i a 9 0 7 5 5 July 24, 2020 RM / KC AS NOTED Z: \ P r o j e c t F o l d e r s \ P r o j e c t s - 2 0 1 8 \ 9 4 4 V i a L i d o N o r d T r u s t \ 3 - P l o t S h e e t s \ A 2 . 2 S e c o n d F l o o r P l a n . d w g A2.2 Second Floor Plan SECOND FLOOR PLAN A2.2 SECOND FLOOR PLAN SCALE: 1/4" = 1'-0"1 WALL LEGEND: NEW 2X4 WALLS NEW 2X6 WALLS FLOOR PLAN KEYNOTES: 1.00 PLAN NOTES: SYMBOL LEGEND: * - ELEVATION / SECTION CALLOUT - KEYNOTE - DETAIL CALLOUT - INTERIOR ELEVATION CALLOUT - DOOR CALLOUT - WINDOW CALLOUT - EGRESS WINDOW 1 AD.1 1 A3.0 1 A5.0 A B C D 1.00 A 1 - SIZE / TYPE SIZE / TYPE - NEW DOOR - EXISTING DOOR - NEW WINDOW - EXIST. WINDOW - REFER TO EXIST. - PLAN FOR SIZE - REFER TO EXIST. - PLAN FOR SIZE - TEMPERED GLASS 1.01 1.02 SINGLE 2x4 STUD FRAMED WALL WINDOW DOOR1.03 1.04 1.05 1.06 1.07 1.08 1.09 1.10 1.11 1.12 1.13 1.18 1.19 SHELF AND POLE NOT USED SINK W/ GARBAGE DISPOSAL 1.14 1.15 1.16 1.17 SINGLE 2x6 STUD FRAMED WALL LOWER CABINETS 30" COOK TOP 30" REFRIGERATOR 1.20 1.21 1.22 1.23 1.24 SHOWER WATER CLOSET LAVATORY SINK DRYER METAL STAIRS W/ 36" CABLE HANDRAILS CABLE STAIR RAILING WASHER TANKLESS WATER HEATER ELECTRICAL SERVICE PANEL GAS METER - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ALL BEDROOMS, BASEMENTS OR ROOMS USED FOR SLEEPING SHALL HAVE EMERGENCY RESCUE WINDOWS OR DOORS. A.MIN. NET CLEAR OPENING OF 5.7 SQ. FT. B.MIN. NET CLEAR OPENING WIDTH OF 20". C.MIN. NET CLEAR HEIGHT OF 24". D.WINDOW SILL HEIGHT OF NOT MORE THAN 44" ABOVE THE FLOOR. 1.ALL WORK PERFORMED ON THIS PROJECT SHALL BE IN CONFORMANCE WITH THESE PLANS AND THE STANDARDS SET BY THE LOCAL BUILDING OFFICIAL. 2.SMOKE DETECTORS SHALL BE INTERCONNECTED TO SOUND AN ALARM IN ALL SLEEPING AREAS OF THE DWELLING; BE INSTALLED IN EACH SLEEPING ROOM AND IN THE CORRIDOR OR AREA GIVING ACCESS TO EACH SEPARATE SLEEPING AREA AND BE EQUIPPED WITH A BATTERY BACKUP AS PER CBC SECTION 310.9.1. 3.PROVIDE COMBUSTION AIR TO FORCED AIR UNIT PER CMC SECTION 318 AND TO WATER HEATER PER CPC SECTION 507.3. 4.DOMESTIC DRYER MOISTURE EXHAUST DUCTS SHALL COMPLY WITH CMC SECTION 504.3. 5.ALL DIMENSIONS ARE TO FACE OF STUD OR CONCRETE UNLESS NOTED OTHERWISE. 6.EXHAUST FANS REQUIRED IN BATH AND/OR LAUNDRY ROOMS MUST CONNECT DIRECTLY TO THE OUTSIDE AND MUST PROVIDE 5 AIR CHANGES PER HOUR. CBC SECTION 1203.3. 7.REFER TO DOOR AND WINDOW SCHEDULE FOR ADDITIONAL INFORMATION 8.WATER HEATERS SHALL BE ANCHORED OR STRAPPED TO RESIST HORIZONTAL MOVEMENT IN ACCORDANCE WITH CPC SECTION 510.5. 9.WALL COVERING OF SHOWERS OR TUBS WITHIN SHOWERS SHALL BE OF A CEMENT PLASTER, TILE, OR APPROVED EQUAL, TO A HEIGHT OF NOT LESS THAN 72" ABOVE DRAIN INLET. CEMENT PLASTER BACKING TO BE PROVIDED. 10.STUDS SUPPORTING TWO FLOORS, CEILING, AND ROOF MUST BE 3X4 OR 2X6 AT 16" ON CENTER. CRC TABLE R602.3.(5) 11.EMERGENCY AND ESCAPE RESCUE OPENINGS SHALL HAVE A NET CLEAR OPENING OF NOT LESS THAN 5.7 SQUARE FEET (0.530 M2). THE NET CLEAR OPENING DIMENSIONS REQUIRED BY THIS SECTION SHALL BE OBTAINED BY THE NORMAL OPERATION OF THE EMERGENCY ESCAPE AND RESCUE OPENING FROM THE INSIDE. THE NET CLEAR HEIGHT OPENING SHALL BE NOT LESS THAN 24 INCHES (610 MM) AND THE NET CLEAR WIDTH SHALL BE NOT LESS THAN 20 INCHES (508 MM). EXCEPTION: GRADE FLOOR OR BELOW GRADE OPENINGS SHALL HAVE A NET CLEAR OPENING OF NOT LESS THAN 5 SQUARE FEET (0.465 M2). 12. WINDOW WELLS WITH A VERTICAL DEPTH GREATER THAN 44 INCHES (1118 MM) SHALL BE EQUIPPED WITH A PERMANENTLY AFFIXED LADDER OR STEPS USABLE WITH THE WINDOW IN THE FULLY OPEN POSITION. LADDERS OR STEPS REQUIRED BY THIS SECTION SHALL NOT BE REQUIRED TO COMPLY WITH SECTIONS R311.7 AND R311.8. LADDERS OR RUNGS SHALL HAVE AN INSIDE WIDTH OF NOT LESS THAN 12 INCHES (305 MM), SHALL PROJECT NOT LESS THAN 3 INCHES (76 MM) FROM THE WALL AND SHALL BE SPACED NOT MORE THAN 18 INCHES (457 MM) ON CENTER VERTICALLY FOR THE FULL HEIGHT OF THE WINDOW WELL. 13. GARAGE FLOOR SURFACES SHALL BE OF AN APPROVED NONCOMBUSTIBLE MATERIAL, AND THE AREA USED TO PARK VEHICLES SHALL BE SLOPED TO A DRAIN OR TOWARD THE MAIN VEHICLE ENTRY (R309.1). 14. GARAGES BENEATH HABITABLE ROOMS SHALL BE SEPARATED BY NO LESS THAN 58 INCH TYPE X GYPSUM BOARD APPLIED TO THE UNDERSIDE OF FLOOR FRAMING. PROVIDE MINIMUM 1 2 INCH GYPSUM BOARD ON THE GARAGE SIDES ELSEWHERE.SEE GN.7 15. CBC 708A.4 GARAGE DOOR PERIMETER GAP WEATHER STRIPPING. EXTERIOR GARAGE DOORS SHALL RESIST THE INTRUSION OF EMBERS FROM ENTERING BY PREVENTING GAPS BETWEEN DOORS AND DOOR OPENINGS, AT THE BOTTOM, SIDES AND TOPS OF DOORS, FROM EXCEEDING 1/8 INCH. GAPS BETWEEN DOORS AND DOOR OPENINGS SHALL BE CONTROLLED BY ONE OF THE METHODS LISTED IN THIS SECTION. TRASH BIN STRUCTURAL COLUMN, REFER TO STRUCTURAL PLANS 42" CABLE RAILING T 30'x18' SECTIONAL GARAGE DOOR 30'x18' ROLLUP GARAGE DOOR PR O P E R T Y L I N E P R O P E R T Y L I N E PROPERTY LINE PROPERTY LINE L= 4 6 . 0 0 ' R= 3 8 3 . 1 0 ' = 6 ° 5 2 ' 4 7 " L= 4 0 . 0 0 ' R = 2 4 1 . 7 7 ' = 9 ° 2 8 ' 4 5 " 127.02'N 58°11'08" W 134.97' N 60°57'33" W NOR T H 4'-0" PUBLIC UTILITY EASEMENT/ SETBACK 4'- 0 " SE T B A C K 10'-0" WATER SIDE SETBACK 4' - 0 " SE T B A C K NE I G H B O R I N G B U L K H E A D V I A L I D O N O R D EX I S T I N G B U L K H E A D SE T B A C K SETBACK SE T B A C K SETBACK GHBORING BULKHEAD BULKHEAD SETBACK 3:12 TYP. 3: 1 2 T Y P . 3: 1 2 T Y P . RIDGE 3: 1 2 T Y P . 8" 76'-0 7/8" 5"11'-1" 31 ' - 8 3 / 4 " 22'-2" 5" 5" 5" 5" 8'- 2 " 9'- 3 " 76'-1 7/8"23'-0" 32 ' - 6 3 / 4 " 5" 23'-0"76'-0 7/8" FLAT 1.02 SHINGLES: ROOFING NOTE PER ESR-3267: 4.1.1 GENERAL: WHEN INSTALLED ON NEW CONSTRUCTION IN ACCORDANCE WITH THIS SECTION, THE SHINGLES ARE A CLASS A ROOF COVERING. THE SHINGLES, UNDERLAYMENT AND FLASHINGS MUST BE ACCORDANCE WITH IBC SECTION 1507.2 OR IRC SECTION R905.2 EXCEPT AS NOTED IN THIS REPORT. THE SHINGLES MUST BE INSTALLED OVER ROOF DECKS OF CODE-COMPLYING, MINIMUM 3/8-INCH-THICK (9.5 MM) EXTERIOR-GRADE PLYWOOD; 7/16-INCH-THICK (11.1 MM) ORIENTED STRAND BOARD (OSB); OR NOMINALLY 1-INCH-BY-6-INCH LUMBER INSTALLED AS SOLID SHEATHING CONFORMING TO 2018 AND 2015 IBC SECTIONS 2304.8.2 OR 2308.7.10 (2012, 2009, AND 2006 IBC SECTION 2304.7.2 OR 2308.10.8) OR IRC SECTION R803, AS APPLICABLE, AND UNDERLAYMENT IN ACCORDANCE WITH SECTIONS 3.3 AND 4.1.2.4. MINIMUM ROOF SLOPE MUST BE 2:12 (16.7 PERCENT), EXCEPT FOR GLENWOOD SHINGLE THAT MUST BE INSTALLED ON ROOFS WITH A MINIMUM SLOPE OF 3:12 (25-PERCENT) 8'-11 1/4"± 3'- 8 1 / 2 " ± 4'- 9 7 / 8 " ± 3'- 7 5 / 8 " 3'-7 7/8"± 3'- 7 5 / 8 " 24'-11"±11'-6" 5" 8'-10 5/8" 8" 22 ' - 1 0 3 / 4 " 99'-1 7/8" 2' - 1 0 " TYP. CLASS "A" 1.01 TYP.1.02 TYP. 1.00 TYP. 1.00 TYP. 1.00 TYP. 1.05 TYP. LINE OF BALCONY BELOW RI D G E V A L L E Y FLAT 5"66'-10 1/4" 1.021.02 5" 1 AD.2 1 AD.2 5 AD.2 TYP. TYP.TYP. 5 AD.2 TYP.4 AD.2 2 AD.2 28 ' - 9 3 / 4 " EX I S T I N G D R I V E W A Y A P P R O A C H T O R E M A I N PLOT DATE: SCALE: DESIGN BY: DRAWN BY: CHECKED DATE: FILE NAME: SH E E T S : REVISIONS: BILL DURANT Th e 9 4 4 V i a L i d o N o r d T r u s t 94 4 V i a L i d o N o r d Ne w p o r t B e a c h , C A 9 2 6 6 3 P 562.424.8816 F 562.424.8440 STAMP: BI L L D U R A N T De s i g n e r / B u i l d e r 22 5 9 O r a n g e A v e n u e Si g n a l H i l l , C a l i f o r n i a 9 0 7 5 5 AS NOTED Z: \ P r o j e c t F o l d e r s \ P r o j e c t s - 2 0 1 8 \ 9 4 4 V i a L i d o N o r d T r u s t \ 3 - P l o t S h e e t s \ A 3 . 1 R o o f P l a n . d w g A3.1 Roof Plan BI L L D U R A N T De s i g n e r / B u i l d e r 22 5 9 O r a n g e A v e n u e Si g n a l H i l l , C a l i f o r n i a 9 0 7 5 5 July 24, 2020 RM / KC AS NOTED Z: \ P r o j e c t F o l d e r s \ P r o j e c t s - 2 0 1 8 \ 9 4 4 V i a L i d o N o r d T r u s t \ 3 - P l o t S h e e t s \ A 3 . 1 R o o f P l a n . d w g A3.1 Roof Plan ROOF PLAN A3.1 ROOF PLAN SCALE: 1/4" = 1'-0"1 ROOF NOTES: ROOF KEYNOTES: SYMBOL LEGEND: LINE OF HOUSE BELOW (N) BALCONY BELOW, REFER TO SECOND FLOOR PLAN (N) BORAL STONE MOUNTAIN BLEND, LIGHTWEIGHT CONCRETE, PER ESR 1647 AND/OR UES ER_0412 ATTIC VENT CALCULATION: - ELEVATION / SECTION CALLOUT - DETAIL CALLOUT - INDICATES ROOF SLOPE 1 A4.0 5:12 TYP. 1 AD.1 - INDICATES O'HAGIN ROOF CLOAKED VENT ATTIC AREA = 93932.169 SQUARE IN. (652.30673 SQUARE FT.), PERIMETER = 102'-6 75/128 VENT CALCULATION: 652.30673 S.F./300 = 2.174 S.F. 2.174 S.F. X 144 S.I. = 313.107 S.I. VENT REQUIRED (HIGH): .5 X 313.107 S.I.= 156.553 S.I. VENT PROVIDED (HIGH): 2 VENTS X 98.75 S.I. EA.= 197.5 S.I. VENT REQUIRED (LOW) REMAINDER: 313.107 S.I.- 197.5 S.I. = 115.607 S.I. VENT PROVIDED (LOW): 2 VENTS X 98.75 S.I. EA.= 197.5 S.I. ATTIC AREA NOTE: ALL ROOF SHALL BE FIRE-RETARDANT ROOF COVERING, *MINIMUM CLASS "B" OR NON-COMBUSTIBLE ROOF COVERING. NOTES: 1. INSTALL 2 LAYERS 30# ROOFING FELT 2. INSTALL A SLATE TILE ROOF PER MANUFACTURERS SPECIFICATIONS. 3. RIDGE WILL RECEIVE SLATE RIDGE TILES 4. INSTALL 26 GA. GALVANIZED METAL: PIPE FLASHING, Z-BAR, ROOF TO WALL, SADDLE, DRIP EDGE AND GRAVEL GUARD. 5. INSTALL TWO-PLY TORCH DOWN ROOFING SYSTEM AT LOW SLOPE ROOF AREA(S). 6. ALL PIPES AND VENTS WILL BE SEALED WITH POLYURETHANE CAULK AND PAINTED TO MATCH THE ROOF. 7. INSTALL CORROSION-RESISTANT INTEGRATED RAIN GUTTERS AT EDGE OF SLOPED ROOF. VERIFY LOCATION w/ OWNER. 8. PROVIDE ROOF DRAINS AND OVERFLOW. OVERFLOW TO BE PIPED SEPARATELY. R903.4.1 9. INSTALL CONNECTED CORROSION-RESISTANT DRAIN PIPE(S) WITHIN WALL CAVITY (USE DWV DIRECTIONAL DRAINAGE FITTINGS) CPC 1101.4 AND 706.0. - VERIFY LOCATION w/ OWNER. 10. INSTALL CORROSION-RESISTANT METAL VALLEY FLASHING. 11. * CLASS "A" ROOFING REQUIRED WHERE EMERGENCY EGRESS OPENINGS EXIT ONTO ROOF OR DECK UP TO 5'-0" TO YARD/COURT. WILL REQUIRE 58" TYPE "X" GYP. BD. AT UNDERSIDE OF CONSTRUCTION. SPACE FOR FUTURE SOLAR PANELS 1.00 1.01 1.02 1.03 (N) DOWNSPOUT1.04 (N) COPPER ROOF GUTTER1.05 1.06 (N) BORAL STONE MOUNTAIN BLEND, LIGHTWEIGHT CONCRETE ROOFING PLOT DATE: SCALE: DESIGN BY: DRAWN BY: CHECKED DATE: FILE NAME: SH E E T S : REVISIONS: BILL DURANT Th e 9 4 4 V i a L i d o N o r d T r u s t 94 4 V i a L i d o N o r d Ne w p o r t B e a c h , C A 9 2 6 6 3 P 562.424.8816 F 562.424.8440 STAMP: BI L L D U R A N T De s i g n e r / B u i l d e r 22 5 9 O r a n g e A v e n u e Si g n a l H i l l , C a l i f o r n i a 9 0 7 5 5 AS NOTED Z: \ P r o j e c t F o l d e r s \ P r o j e c t s - 2 0 1 8 \ 9 4 4 V i a L i d o N o r d T r u s t \ 3 - P l o t S h e e t s \ A 3 . 1 R o o f P l a n . d w g A3.1 Roof Plan BI L L D U R A N T De s i g n e r / B u i l d e r 22 5 9 O r a n g e A v e n u e Si g n a l H i l l , C a l i f o r n i a 9 0 7 5 5 July 24, 2020 RM / KC AS NOTED Z: \ P r o j e c t F o l d e r s \ P r o j e c t s - 2 0 1 8 \ 9 4 4 V i a L i d o N o r d T r u s t \ 3 - P l o t S h e e t s \ A 3 . 1 R o o f P l a n . d w g A3.1 Roof Plan DOOR SPECS A5.2 DOOR SPECS 1 FINISHES 2 PR O P E R T Y L I N E P R O P E R T Y L I N E PROPERTY LINE PROPERTY LINE L= 4 6 . 0 0 ' R= 3 8 3 . 1 0 ' = 6 ° 5 2 ' 4 7 " L = 4 0 . 0 0 ' R = 2 4 1 . 7 7 ' = 9 ° 2 8 ' 4 5 " 127.02'N 58°11'08" W 134.97' N 60°57'33" W NOR T H 12 . 4 9 ' T C 12 . 6 2 ' T C 10 . 4 8 ' F S 12. 7 4 ' F G 4'-0" PUBLIC UTILITY EASEMENT/ SETBACK 4' - 0 " SE T B A C K 10'-0" WATER SIDE SETBACK 4' - 0 " SE T B A C K NE I G H B O R I N G B U L K H E A D V I A L I D O N O R D EX I S T I N G B U L K H E A D SE T B A C K SETBACK SE T B A C K SETBACK NE I G H B O R I N G B U L K H E A D 12. 0 1 ' F G 12.5 0 ' F G BULKHEAD SETBACK COVERED PATIO 2-CAR GARAGE 48" 36 "30" 36 " WP 22 0 EV WP WP WP WPWP WP WPWP +84" (PS/M) +84" (PS/M) +84" (PS/M) +84" (PS/M) 3 3 WP WP WP TWH. PLOT DATE: SCALE: DESIGN BY: DRAWN BY: CHECKED DATE: FILE NAME: SH E E T S : REVISIONS: BILL DURANT Th e 9 4 4 V i a L i d o N o r d T r u s t 94 4 V i a L i d o N o r d Ne w p o r t B e a c h , C A 9 2 6 6 3 P 562.424.8816 F 562.424.8440 STAMP: BI L L D U R A N T De s i g n e r / B u i l d e r 22 5 9 O r a n g e A v e n u e Si g n a l H i l l , C a l i f o r n i a 9 0 7 5 5 AS NOTED Z: \ P r o j e c t F o l d e r s \ P r o j e c t s - 2 0 1 8 \ 9 4 4 V i a L i d o N o r d T r u s t \ 3 - P l o t S h e e t s \ A 4 . 2 F i r s t F l o o r U t i l i t y P l a n . d w g A4.2 First Floor Utility Plan BI L L D U R A N T De s i g n e r / B u i l d e r 22 5 9 O r a n g e A v e n u e Si g n a l H i l l , C a l i f o r n i a 9 0 7 5 5 July 24, 2020 RM / KC AS NOTED Z: \ P r o j e c t F o l d e r s \ P r o j e c t s - 2 0 1 8 \ 9 4 4 V i a L i d o N o r d T r u s t \ 3 - P l o t S h e e t s \ A 4 . 2 F i r s t F l o o r U t i l i t y P l a n . d w g A4.2 First Floor Utility Plan UTILITY PLAN A4.2 FIRST FLOOR UTILITY PLAN SCALE: 1/4" = 1'-0"1 ELECTRICAL NOTES: ELECTRIC BASEBOARD HEATER CEILING FAN GENERAL ELECTRICAL SMOKE DETECTOR HARD-WIRED INTO ELECTRICAL (WITH A 10-YEAR LIFE BACKUP BATTERY. DETECTORS SHALL OUTLETS 220V OUTLET 110 V CONV DUPLEX OUTLET 110 V CONV DUPLEX OUTLET - HALF HOT SWITCHES SWITCH DIMMER SWITCH 4-WAY SWITCH 3-WAY SWITCH CLIMATE CONTROL DATA CABLE FLOOR OUTLET JUNCTION BOXJ INTERRUPTED DUPLEX OUTLET GROUND FAULT INTERRUPTED DUPLEX OUTLET WEATHERPROOF GROUND FAULT V WALL-HUNG LIGHT FIXTURE LIGHTING/EXHAUST FANS RECESSED HIGH-EFFICACY LIGHT FIXTURE F DRYER VENT VAPOR-PROOF RECESSED LIGHT FIXTURE ELECTRICAL LEGEND: 220 D GFI WP S.D. 3 4 D WALL-MOUNT MULTI-LIGHT FIXTURE C.M. CARBON MONOXIDE SENSOR HARD-WIRED INTO HE VS VACANCY SENSOR SWITCH, TYP. BATHROOM DRAWER POWER STRIP CONVENIENCE TV OR PHONE CABINET WALL FIXTURE SWITCH CONVENIENCE OUTLET NO SCALE TYP. INSTALLATION HEIGHT UNLESS OTHERWISE NOTED 82 " A T B A T H 46 " A T S T A N D . 38 " T Y P . IN S P L A S H 43 " A T B A T H 49 " A T K I T . / U T I L . 49 " A T G A R A G E 48 " A T P A T I O 72 " UNLESS OTHERWISE NOTED 72 " PO L E H E I G H T 12" MIN. SHELF 6"12" 24" 1. PROVIDE 2" CLEAR FROM STORAGE AREA WHEN INSTALLING INCANDECENT FIXTURES. 2. EXPOSED BULB FIXTUREA ARE NOT PERMITTED..3. STORAGE AREA CONVENIENCE TV OR PHONE CABINET WALL FIXTURE SWITCH CONVENIENCE OUTLET NO SCALE TYP. INSTALLATION HEIGHT UNLESS OTHERWISE NOTED 18 " 42 " A T D E N 49 " A T G A R A G E 48 " A T P A T I O UNLESS OTHERWISE NOTED 6"12" 1. PROVIDE 2" CLEAR FROM STORAGE AREA WHEN INSTALLING INCANDECENT FIXTURES. 2. EXPOSED BULB FIXTUREA ARE NOT PERMITTED..3. STORAGE AREA SOUND AN ALARM AUDIBLE IN ALL SLEEPING AREAS) ELECTRICAL EXHAUST FAN. 110 CFM BATHS ON A PROGRAMMABLE TIMER. 400 CFM AT KITCHEN CRC R303.3 EXHAUST FAN FLUORESCENT LIGHT COMBO - 50 CFM MIN - VENTED TO OUTSIDE AIR. SWITCHED SEPARATELY FROM LIGHTING. PHOTO SENSOR & MOTION WALL-HUNG LIGHT FIXTURE (PS/M) PROVIDE 6" CLEAR FROM STORAGE AREA WHEN INSTALLING FLOURECENT OR RECESSED FIXTURES. NO SCALE TYP. INSTALLATION CLOSET FIXTURE NO SCALE TYP. INSTALLATION CLOSET FIXTURE HUMIDISTAT 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. Tankless water heater. Verify all clearances and installation requirements per manufacturer's recommendations. Provide waste drain, hot, and cold water w/ shut-off valves recessed into wall for washing machine. Provide pan and drain by Plumber. All receptacles in bathrooms and all locations within 6'- 0" of sinks shall be G.F.C.I.. (Per C.E.C. 210-8(A). Return air grill located in wall, or ceiling. (Verify with plan.) Provide an approved (non-removable) backflow valve and anti- siphon device at all hose bibbs. (Provide T-valve for future landscape sprinkler system.) Verify w/ City. 30"x 30" attic access panel in ceiling, section 1501.2 2019 C.B.C. 22"x30" min. verify w/ FAU manufacturer specification. Mechanical ventilation for toilet compartments, bath, and laundry rooms shall be capable of providing 5 air changes per hour per Section 1203.3 C.B.C. approval is required prior to installation. Maintain three feet clear from face of electrical panel to any wall surface or obstruction. Provide capped fuel gas outlet and shut-off valve. L.E.D. Fixture. Provide 40 lumens per watt efficiency per T-24. Provide smoke detector within 12" of the ceiling at this shown location. Smoke detectors to be inter-connected with each other and hardwired to a battery back-up system. Smoke detectors shall sound an audible alarm in all sleeping areas. 21. 22. Provide one light circuit for each 500 sq. ft. of livable area. Provide two 20-amp small appliance circuits and one 20-amp laundry circuit. 23. 24. 25. 26. 27. 28. Provide two (2) G.F.C.I. water-resistant receptacles minimum on the outside of building, one in front and back. It is the applicant's responsibility to provide 'City of Long Beach' installations of CEC listed features, devices, and equipment, and to comply with applicable regulations. 29. 30. 31. 32. 33. 34. 40. Ceiling mounted 'J' box with switch for optional ceiling fan or ceiling-mounted light fixture. Fireplace gas valves must be located outside of required hearth area, but not more than 48". Existing gas meter to remain. Verify Location. Provide 1/2 hot receptacle interconnected to switch in shown location. Cable television connection in or around designated location. Telephone jack (PJ) connection in or around designated location. Broadband connection in or around designated location. All 15 and 20 ampere branch circuits/outlets to be A.F.C.I. per CEC 210.12(A) Thermostat. Provide power and hardwire for future installation or as required per manufacturer. Provide combination smoke/carbon monoxide detector per CRC R314 and R315. 35. 36. 37. 38. 39. All stairways shall have an illumination level on tread runs of not less than 1 foot candle (11 LUX) CBC 1205.4 Bathroom exhaust fans (with shower, tub or combination) shall have humidistat control. Per CGBSC 4.506.1 (1 and 2). ENERGY STAR compliant. Recessed lighting in insulated ceiling must meet requirements of Section 150 (k) 12. See Detail A (herein) for concrete-encased grounding rod. See Detail B (ESR) (herein) for proper installation of service meter (per So Cal Edison). A 120V electric receptacle shall be located within 3 ft. from water heater and be accessible to the water heater without obstructions CENC 150 (n)1A). Water heater and HVAC units shall be accessible for inspection, service, repair, and placement without removing permanent structures. Not less than 30 inches (762 mm) in depth, width, and height of working space shall be provided. (Section 304.1). Exterior light fixtures & weatherproof outlets shall be installed per CEC 410.10(A)&(D) & 406.9. Receptacles at the front and rear of the home must be within 6 feet 6 inches of grade (and waterproof and GFCI protected). CEC 210.52 E & 210.8 (A). Whole-house fan: Stealth Pro 3.3 cfm. Per Energy Calcs. Provide outlet. Whole-house fan: Stealth Pro 6.5 cfm. Per Energy Calcs. Provide outlet. Provide outlet and lights in attics containing F.A.U. Dimmer-controlled receptacles shall be listed for use. Electrical panel location to be verified. Edison Company approval is shall have no other outlets. This circuit may serve more than one bathroom. CEC 210-11 (c). GENERAL NOTES VERIFY LOCATIONS OF SMOKE AND CO ALARMS Smoke Alarms Exceptions:  In dwelling units where there is no commercial power supply, the smoke alarm may be solely battery-operated.  In existing dwelling units, a smoke alarm is permitted to be solely battery-operated where repairs or alterations do not result in the removal of wall and ceiling finishes if there is no access by means of attic, basement or crawl space.  In existing dwelling units, a smoke alarm is permitted to be solely battery-operated or plug-in with battery back-up where repairs or alterations are limited to the exterior surfaces of dwellings, such as the replacement of roofing or siding, or the addition or replacement of windows or doors, or the addition of a porch or deck. In existing dwelling units, a CO alarm is permitted to be solely battery operated or plug-in with battery back-up where work is limited to installation, alteration or repair of plumbing or mechanical systems. Carbon Monoxide Alarms Exceptions:  Where listed wireless alarms are installed and all alarms sound upon activation of one alarm.  Interconnection is not required in existing dwelling units where repairs do not result in the removal of wall and ceiling finishes, there is no access by means of attic, basement or crawl space, and no previous method for interconnection existed.  In existing dwelling units, CO alarms are not required to be interconnected where no constructionis taking place.  In existing dwelling units, CO alarms are not required to be interconnected where repairs oralterations are limited to the exterior surfaces of dwellings, such as the replacement of roofing orsiding, or the addition or replacement of windows or doors, or the addition of a porch or deck.  In existing dwelling units, CO alarms not required to be interconnected when work is limited to the installation, alteration or repair of plumbing, mechanical, or electrical systems Walls spaced 24" and wider shall have a receptacle every 12 feet. Minimum (1) 20-amp circuit for bathroom(s) outlet. Such circuit 41.Single- and multiple-station smoke alarms shall be installed in the following locations (R314.3): a.In each sleeping room. b.Outside of each separate sleeping area in the immediate vicinity of the bedrooms. c.On each additional story of the dwelling, including basements and habitable attics, but not including crawl spaces and uninhabitable attics. d.Smoke alarms shall be installed not less than 3 feet horizontally from the door or opening of a bathroom that contains a bathtub or shower unless this would prevent the placement of a smoke alarm required by Section R314.3 ALL LIGHTING/FAN FIXTURES LOCATED IN WET OR DAMP LOCATIONS SHALL BE RATED FOR THE APPLICATION. (CEC 410.10) - U.L. APPROVED, ALL LIGHTING/FAN FIXTURES LOCATED IN WET OR DAMP LOCATIONS SHALL BE RATED FOR THE APPLICATION. (CEC 410.10) Receptacles shall not be installed within or directly over a bathtub or shower stall. (CEC 406.9(C) Light pendants, ceiling fans, lighting tracks, etc. shall not be located within 3ft horizontally and 8ft vertically above a shower and/or bathtub threshold. (CEC 410.10(D)) 42. All 15/20 ampere receptacles installed per CEC 210.52 shall be listed as tamper-resistant receptacles. (CEC 406.12) *REFER TO NOTE #32 ABOVE All outlets are to be AFCI.43. All lights are high efficacy.44. 45. 46. All receptacles that are required to be GFCI shall be a combination of AFCI, GFCI (CEC 210.52(E)(1)) All new receptacles in bathroom wet areas or over the counter, shall be a combination of GFCI and AFCI per 2019 code requirements HUMIDISTAT 20.FIELD INSPECTORS TO REVIEW AND APPROVE UNDERGROUND SERVICE REQUIREMENTS PRIOR TO CONCRETE PLACEMENT. A.RESIDENTIAL LIGHTING SHALL COMPLY WITH SECTION 150(K) HIGH EFFICACY = 40 LUMENS PER WATT. B.KITCHEN LIGHTING SHALL BE HIGH-EFFICACY LUMINARIES. PROVIDE WORKSHEET WS-5R. 50% OF KITCHEN LIGHTING TO COMPLY. (BASED ON WATTAGE). C.BATHROOMS, GARAGES, LAUNDRY ROOMS AND UTILITY ROOMS SHALL BE HIGH-EFFICACY LUMINARIES OR CONTROLLED BY AN OCCUPANCY SENSOR CERTIFIED TO COMPLY WITH SECTION 119(D). D.GENERAL RESIDENTIAL LIGHTING SHALL BE HIGH-EFFICACY LUMINARIES OR CONTROLLED BY A DIMMER SWITCH CERTIFIED TO COMPLY WITH SECTION 119(D) E.RECESSED LUMINARIES INSTALLED IN AN INSULATED CEILING SHALL BE IC RATED (ZERO CLEARANCE) AND AT RATED (AIR-TIGHT) AND SHALL BE SEALED AND/OR GASKETED BETWEEN CEILING AND HOUSING. F.OUTDOOR LIGHTING SHALL BE HIGH-EFFICACY LUMINARIES OR CONTROLLED BY A MOTION SENSOR WITH INTEGRAL PHOTO-CONTROL CERTIFIED TO COMPLY WITH SECTION 119(D) G.2-20 AMP. SMALL APPLIANCE CIRCUITS ARE REQUIRED FOR KITCHEN COUNTERTOPS. THE LOAD SHALL BE BALANCED AND GFCI PROTECTED. G.A. A.F.C.I. PROTECTION FOR ALL BEDROOM CIRCUITS PER (2019 CEC SEC. 210.12) BASEBOARD HEATER THERMOSTAT FIRST FLOOR PR O P E R T Y L I N E P R O P E R T Y L I N E PROPERTY LINE PROPERTY LINE L= 4 6 . 0 0 ' R= 3 8 3 . 1 0 ' = 6 ° 5 2 ' 4 7 " L = 4 0 . 0 0 ' R = 2 4 1 . 7 7 ' = 9 ° 2 8 ' 4 5 " 127.02'N 58°11'08" W 134.97' N 60°57'33" W NOR T H 4'-0" PUBLIC UTILITY EASEMENT/ SETBACK 4' - 0 " SE T B A C K 10'-0" WATER SIDE SETBACK 4' - 0 " SE T B A C K NE I G H B O R I N G B U L K H E A D V I A L I D O N O R D EX I S T I N G B U L K H E A D SE T B A C K SETBACK SE T B A C K SETBACK GHBORING BULKHEAD BULKHEAD SETBACK 1/4:12 TYP. 1/ 4 : 1 2 T Y P . HE GF I +4 8 " SM KIT. VAULTED 22 0 100 CFM CW VS GFI+48"SM HE GFI HE V S 110 CFM USB MIN. (1) 20A CIRCUIT FOR BATHROOM RECEPTACLE OUTLETS (CEC 210.11(C)(3) GF I +4 8 " SM GF I +4 8 " SM HE HE HE HE HE HE HEHE HE GFI V S 110 CFM GF I +4 8 " SM HE VS 3 HE MIN. (1) 20A CIRCUIT FOR BATHROOM RECEPTACLE OUTLETS (CEC 210.11(C)(3) VS 3 VS 3 VS 3 VS 3 VS 3 VS 3 VS 3 WP PS +84" (PS/M) PS +84" (PS/M) +84" (PS/M) +84" (PS/M) HE HE WP WP PLOT DATE: SCALE: DESIGN BY: DRAWN BY: CHECKED DATE: FILE NAME: SH E E T S : REVISIONS: BILL DURANT Th e 9 4 4 V i a L i d o N o r d T r u s t 94 4 V i a L i d o N o r d Ne w p o r t B e a c h , C A 9 2 6 6 3 P 562.424.8816 F 562.424.8440 STAMP: BI L L D U R A N T De s i g n e r / B u i l d e r 22 5 9 O r a n g e A v e n u e Si g n a l H i l l , C a l i f o r n i a 9 0 7 5 5 AS NOTED Z: \ P r o j e c t F o l d e r s \ P r o j e c t s - 2 0 1 8 \ 9 4 4 V i a L i d o N o r d T r u s t \ 3 - P l o t S h e e t s \ A 4 . 3 S e c o n d F l o o r U t i l i t y P l a n . d w g A4.3 Second Floor Utility Plan BI L L D U R A N T De s i g n e r / B u i l d e r 22 5 9 O r a n g e A v e n u e Si g n a l H i l l , C a l i f o r n i a 9 0 7 5 5 July 24, 2020 RM / KC AS NOTED Z: \ P r o j e c t F o l d e r s \ P r o j e c t s - 2 0 1 8 \ 9 4 4 V i a L i d o N o r d T r u s t \ 3 - P l o t S h e e t s \ A 4 . 3 S e c o n d F l o o r U t i l i t y P l a n . d w g A4.3 Second Floor Utility Plan A4.3 SECOND FLOOR UTILITY PLAN SCALE: 1/4" = 1'-0"1 ELECTRICAL NOTES: ELECTRIC BASEBOARD HEATER CEILING FAN GENERAL ELECTRICAL SMOKE DETECTOR HARD-WIRED INTO ELECTRICAL (WITH A 10-YEAR LIFE BACKUP BATTERY. DETECTORS SHALL OUTLETS 220V OUTLET 110 V CONV DUPLEX OUTLET 110 V CONV DUPLEX OUTLET - HALF HOT SWITCHES SWITCH DIMMER SWITCH 4-WAY SWITCH 3-WAY SWITCH CLIMATE CONTROL DATA CABLE FLOOR OUTLET JUNCTION BOXJ INTERRUPTED DUPLEX OUTLET GROUND FAULT INTERRUPTED DUPLEX OUTLET WEATHERPROOF GROUND FAULT V WALL-HUNG LIGHT FIXTURE LIGHTING/EXHAUST FANS RECESSED HIGH-EFFICACY LIGHT FIXTURE F DRYER VENT VAPOR-PROOF RECESSED LIGHT FIXTURE ELECTRICAL LEGEND: 220 D GFI WP S.D. 3 4 D WALL-MOUNT MULTI-LIGHT FIXTURE C.M. CARBON MONOXIDE SENSOR HARD-WIRED INTO HE VS VACANCY SENSOR SWITCH, TYP. BATHROOM DRAWER POWER STRIP CONVENIENCE TV OR PHONE CABINET WALL FIXTURE SWITCH CONVENIENCE OUTLET NO SCALE TYP. INSTALLATION HEIGHT UNLESS OTHERWISE NOTED 82 " A T B A T H 46 " A T S T A N D . 38 " T Y P . IN S P L A S H 43 " A T B A T H 49 " A T K I T . / U T I L . 49 " A T G A R A G E 48 " A T P A T I O 72 " UNLESS OTHERWISE NOTED 72 " PO L E H E I G H T 12" MIN. SHELF 6" 12" 24" 1. PROVIDE 2" CLEAR FROM STORAGE AREA WHEN INSTALLING INCANDECENT FIXTURES. 2. EXPOSED BULB FIXTUREA ARE NOT PERMITTED..3. STORAGE AREA CONVENIENCE TV OR PHONE CABINET WALL FIXTURE SWITCH CONVENIENCE OUTLET NO SCALE TYP. INSTALLATION HEIGHT UNLESS OTHERWISE NOTED 18 " 42 " A T D E N 49 " A T G A R A G E 48 " A T P A T I O UNLESS OTHERWISE NOTED 6" 12" 1. PROVIDE 2" CLEAR FROM STORAGE AREA WHEN INSTALLING INCANDECENT FIXTURES. 2. EXPOSED BULB FIXTUREA ARE NOT PERMITTED..3. STORAGE AREA SOUND AN ALARM AUDIBLE IN ALL SLEEPING AREAS) ELECTRICAL EXHAUST FAN. 110 CFM BATHS ON A PROGRAMMABLE TIMER. 400 CFM AT KITCHEN CRC R303.3 EXHAUST FAN FLUORESCENT LIGHT COMBO - 50 CFM MIN - VENTED TO OUTSIDE AIR. SWITCHED SEPARATELY FROM LIGHTING. PHOTO SENSOR & MOTION WALL-HUNG LIGHT FIXTURE (PS/M) PROVIDE 6" CLEAR FROM STORAGE AREA WHEN INSTALLING FLOURECENT OR RECESSED FIXTURES. NO SCALE TYP. INSTALLATION CLOSET FIXTURE NO SCALE TYP. INSTALLATION CLOSET FIXTURE HUMIDISTAT 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. Tankless water heater. Verify all clearances and installation requirements per manufacturer's recommendations. Provide waste drain, hot, and cold water w/ shut-off valves recessed into wall for washing machine. Provide pan and drain by Plumber. All receptacles in bathrooms and all locations within 6'- 0" of sinks shall be G.F.C.I.. (Per C.E.C. 210-8(A). Return air grill located in wall, or ceiling. (Verify with plan.) Provide an approved (non-removable) backflow valve and anti- siphon device at all hose bibbs. (Provide T-valve for future landscape sprinkler system.) Verify w/ City. 30"x 30" attic access panel in ceiling, section 1501.2 2019 C.B.C. 22"x30" min. verify w/ FAU manufacturer specification. Mechanical ventilation for toilet compartments, bath, and laundry rooms shall be capable of providing 5 air changes per hour per Section 1203.3 C.B.C. approval is required prior to installation. Maintain three feet clear from face of electrical panel to any wall surface or obstruction. Provide capped fuel gas outlet and shut-off valve. L.E.D. Fixture. Provide 40 lumens per watt efficiency per T-24. Provide smoke detector within 12" of the ceiling at this shown location. Smoke detectors to be inter-connected with each other and hardwired to a battery back-up system. Smoke detectors shall sound an audible alarm in all sleeping areas. 21. 22. Provide one light circuit for each 500 sq. ft. of livable area. Provide two 20-amp small appliance circuits and one 20-amp laundry circuit. 23. 24. 25. 26. 27. 28. Provide two (2) G.F.C.I. water-resistant receptacles minimum on the outside of building, one in front and back. It is the applicant's responsibility to provide 'City of Long Beach' installations of CEC listed features, devices, and equipment, and to comply with applicable regulations. 29. 30. 31. 32. 33. 34. 40. Ceiling mounted 'J' box with switch for optional ceiling fan or ceiling-mounted light fixture. Fireplace gas valves must be located outside of required hearth area, but not more than 48". Existing gas meter to remain. Verify Location. Provide 1/2 hot receptacle interconnected to switch in shown location. Cable television connection in or around designated location. Telephone jack (PJ) connection in or around designated location. Broadband connection in or around designated location. All 15 and 20 ampere branch circuits/outlets to be A.F.C.I. per CEC 210.12(A) Thermostat. Provide power and hardwire for future installation or as required per manufacturer. Provide combination smoke/carbon monoxide detector per CRC R314 and R315. 35. 36. 37. 38. 39. All stairways shall have an illumination level on tread runs of not less than 1 foot candle (11 LUX) CBC 1205.4 Bathroom exhaust fans (with shower, tub or combination) shall have humidistat control. Per CGBSC 4.506.1 (1 and 2). ENERGY STAR compliant. Recessed lighting in insulated ceiling must meet requirements of Section 150 (k) 12. See Detail A (herein) for concrete-encased grounding rod. See Detail B (ESR) (herein) for proper installation of service meter (per So Cal Edison). A 120V electric receptacle shall be located within 3 ft. from water heater and be accessible to the water heater without obstructions CENC 150 (n)1A). Water heater and HVAC units shall be accessible for inspection, service, repair, and placement without removing permanent structures. Not less than 30 inches (762 mm) in depth, width, and height of working space shall be provided. (Section 304.1). Exterior light fixtures & weatherproof outlets shall be installed per CEC 410.10(A)&(D) & 406.9. Receptacles at the front and rear of the home must be within 6 feet 6 inches of grade (and waterproof and GFCI protected). CEC 210.52 E & 210.8 (A). Whole-house fan: Stealth Pro 3.3 cfm. Per Energy Calcs. Provide outlet. Whole-house fan: Stealth Pro 6.5 cfm. Per Energy Calcs. Provide outlet. Provide outlet and lights in attics containing F.A.U. Dimmer-controlled receptacles shall be listed for use. Electrical panel location to be verified. Edison Company approval is shall have no other outlets. This circuit may serve more than one bathroom. CEC 210-11 (c). GENERAL NOTES VERIFY LOCATIONS OF SMOKE AND CO ALARMS Smoke Alarms Exceptions:  In dwelling units where there is no commercial power supply, the smoke alarm may be solely battery-operated.  In existing dwelling units, a smoke alarm is permitted to be solely battery-operated where repairs or alterations do not result in the removal of wall and ceiling finishes if there is no access by means of attic, basement or crawl space.  In existing dwelling units, a smoke alarm is permitted to be solely battery-operated or plug-in with battery back-up where repairs or alterations are limited to the exterior surfaces of dwellings, such as the replacement of roofing or siding, or the addition or replacement of windows or doors, or the addition of a porch or deck. In existing dwelling units, a CO alarm is permitted to be solely battery operated or plug-in with battery back-up where work is limited to installation, alteration or repair of plumbing or mechanical systems. Carbon Monoxide Alarms Exceptions:  Where listed wireless alarms are installed and all alarms sound upon activation of one alarm.  Interconnection is not required in existing dwelling units where repairs do not result in the removal of wall and ceiling finishes, there is no access by means of attic, basement or crawl space, and no previous method for interconnection existed.  In existing dwelling units, CO alarms are not required to be interconnected where no constructionis taking place.  In existing dwelling units, CO alarms are not required to be interconnected where repairs oralterations are limited to the exterior surfaces of dwellings, such as the replacement of roofing orsiding, or the addition or replacement of windows or doors, or the addition of a porch or deck.  In existing dwelling units, CO alarms not required to be interconnected when work is limited to the installation, alteration or repair of plumbing, mechanical, or electrical systems Walls spaced 24" and wider shall have a receptacle every 12 feet. Minimum (1) 20-amp circuit for bathroom(s) outlet. Such circuit 41.Single- and multiple-station smoke alarms shall be installed in the following locations (R314.3): a.In each sleeping room. b.Outside of each separate sleeping area in the immediate vicinity of the bedrooms. c.On each additional story of the dwelling, including basements and habitable attics, but not including crawl spaces and uninhabitable attics. d.Smoke alarms shall be installed not less than 3 feet horizontally from the door or opening of a bathroom that contains a bathtub or shower unless this would prevent the placement of a smoke alarm required by Section R314.3 ALL LIGHTING/FAN FIXTURES LOCATED IN WET OR DAMP LOCATIONS SHALL BE RATED FOR THE APPLICATION. (CEC 410.10) - U.L. APPROVED, ALL LIGHTING/FAN FIXTURES LOCATED IN WET OR DAMP LOCATIONS SHALL BE RATED FOR THE APPLICATION. (CEC 410.10) Receptacles shall not be installed within or directly over a bathtub or shower stall. (CEC 406.9(C) Light pendants, ceiling fans, lighting tracks, etc. shall not be located within 3ft horizontally and 8ft vertically above a shower and/or bathtub threshold. (CEC 410.10(D)) 42. All 15/20 ampere receptacles installed per CEC 210.52 shall be listed as tamper-resistant receptacles. (CEC 406.12) *REFER TO NOTE #32 ABOVE All outlets are to be AFCI.43. All lights are high efficacy.44. 45. 46. All receptacles that are required to be GFCI shall be a combination of AFCI, GFCI (CEC 210.52(E)(1)) All new receptacles in bathroom wet areas or over the counter, shall be a combination of GFCI and AFCI per 2019 code requirements HUMIDISTAT 20.FIELD INSPECTORS TO REVIEW AND APPROVE UNDERGROUND SERVICE REQUIREMENTS PRIOR TO CONCRETE PLACEMENT. A.RESIDENTIAL LIGHTING SHALL COMPLY WITH SECTION 150(K) HIGH EFFICACY = 40 LUMENS PER WATT. B.KITCHEN LIGHTING SHALL BE HIGH-EFFICACY LUMINARIES. PROVIDE WORKSHEET WS-5R. 50% OF KITCHEN LIGHTING TO COMPLY. (BASED ON WATTAGE). C.BATHROOMS, GARAGES, LAUNDRY ROOMS AND UTILITY ROOMS SHALL BE HIGH-EFFICACY LUMINARIES OR CONTROLLED BY AN OCCUPANCY SENSOR CERTIFIED TO COMPLY WITH SECTION 119(D). D.GENERAL RESIDENTIAL LIGHTING SHALL BE HIGH-EFFICACY LUMINARIES OR CONTROLLED BY A DIMMER SWITCH CERTIFIED TO COMPLY WITH SECTION 119(D) E.RECESSED LUMINARIES INSTALLED IN AN INSULATED CEILING SHALL BE IC RATED (ZERO CLEARANCE) AND AT RATED (AIR-TIGHT) AND SHALL BE SEALED AND/OR GASKETED BETWEEN CEILING AND HOUSING. F.OUTDOOR LIGHTING SHALL BE HIGH-EFFICACY LUMINARIES OR CONTROLLED BY A MOTION SENSOR WITH INTEGRAL PHOTO-CONTROL CERTIFIED TO COMPLY WITH SECTION 119(D) G.2-20 AMP. SMALL APPLIANCE CIRCUITS ARE REQUIRED FOR KITCHEN COUNTERTOPS. THE LOAD SHALL BE BALANCED AND GFCI PROTECTED. G.A. A.F.C.I. PROTECTION FOR ALL BEDROOM CIRCUITS PER (2019 CEC SEC. 210.12) BASEBOARD HEATER THERMOSTAT SECOND FLOOR UTILITY PLAN 29 ' - 0 " 4" 19 ' - 1 0 3 / 4 " 4" 24 ' - 0 " 29 ' - 0 " T.O. PLATE H.O.A: T.O. CURB (12.55')H.O.A: T.O. CURB (12.55') 17 ' - 9 " 23 ' - 9 3 / 4 " F.G. 12.36 F.G. 12.36' CITY OF NEWPORT BEACH 29.00'+ CITY ESTAB. GRADE (11.93')= 40.93' NAVD88 MAX. SLOPED ROOF HEIGHT CITY OF NEWPORT BEACH 24.00'+ CITY ESTAB. GRADE (11.93')= 35.93' NAVD88 MAX. PARAPET/ FLAT ROOF HEIGHT MAX. SLOPED ROOF HEIGHT MAX. PARAPET/ FLAT ROOF HEIGHT CITY OF NEWPORT BEACH 24.00'+ CITY ESTAB. GRADE (11.93')= 35.93' NAVD88 CITY OF NEWPORT BEACH 29.00'+ CITY ESTAB. GRADE (11.93')= 40.93' NAVD88 24 ' - 0 " 8' - 0 " 8" 28'-10" 20'-0" 8' - 0 3 / 4 " 9' - 0 " 4'-5"1'-5 1/4"4'-5"1'-5 1/4" CITY AVG. (11.93')CITY AVG. (11.93') T.O.STRUCT. SLAB (12.70') T.O.STRUCT. SLAB (12.70') A 29 ' - 0 " 6' - 8 5 / 8 " T.O. PLATE H.O.A: T.O. CURB (12.55')F.G. 12.36' MAX. SLOPED ROOF HEIGHT MAX. PARAPET/ FLAT ROOF HEIGHT CITY OF NEWPORT BEACH 24.00'+ CITY ESTAB. GRADE (11.93')= 35.93' NAVD88 CITY OF NEWPORT BEACH 29.00'+ CITY ESTAB. GRADE (11.93')= 40.93' NAVD88 24 ' - 0 " F.G. (12.36') 29 ' - 0 " 4" 19 ' - 6 3 / 4 " 13 ' - 4 " T.O. PLATE T.O. PLATE H.O.A: T.O. CURB (12.55') 23 ' - 9 3 / 4 " 23 ' - 9 3 / 4 " T.O.STRUCT. SLAB (12.70') F.G. 12.36' MAX. SLOPED ROOF HEIGHT MAX. PARAPET/ FLAT ROOF HEIGHT CITY OF NEWPORT BEACH 24.00'+ CITY ESTAB. GRADE (11.93')= 35.93' NAVD88 CITY OF NEWPORT BEACH 29.00'+ CITY ESTAB. GRADE (11.93')= 40.93' NAVD88 CITY AVG. (11.93') 24 ' - 0 " 1' - 0 " 11 ' - 3 3 / 4 " 8'-10 3/4" 2'-1 3/4"2'-1 3/4"2'-1 3/4"20'-0 1/4"20'-0 1/4"21'-0 1/4" 3'-0" 5'- 8 " 2' - 0 " 15 ' - 2 " CITY AVG. (11.93') 22'-2" T.O.STRUCT. SLAB (12.70') 19 ' - 1 0 3 / 4 " 1' - 3 " 4" 11 ' - 7 3 / 4 " 12 ' - 1 0 3 / 4 " STAIRS BEYOND COVERED PATIO COVERED PATIO 1 1 1 PLOT DATE: SCALE: DESIGN BY: DRAWN BY: CHECKED DATE: FILE NAME: SH E E T S : REVISIONS: BILL DURANT Th e 9 4 4 V i a L i d o N o r d T r u s t 94 4 V i a L i d o N o r d Ne w p o r t B e a c h , C A 9 2 6 6 3 P 562.424.8816 F 562.424.8440 STAMP: BI L L D U R A N T De s i g n e r / B u i l d e r 22 5 9 O r a n g e A v e n u e Si g n a l H i l l , C a l i f o r n i a 9 0 7 5 5 AS NOTED Z: \ P r o j e c t F o l d e r s \ P r o j e c t s - 2 0 1 8 \ 9 4 4 V i a L i d o N o r d T r u s t \ 3 - P l o t S h e e t s \ A 5 . 1 E x t e r i o r E l e v a t i o n s . d w g A5.1 Exterior Elevations BI L L D U R A N T De s i g n e r / B u i l d e r 22 5 9 O r a n g e A v e n u e Si g n a l H i l l , C a l i f o r n i a 9 0 7 5 5 July 24, 2020 RM / KC AS NOTED Z: \ P r o j e c t F o l d e r s \ P r o j e c t s - 2 0 1 8 \ 9 4 4 V i a L i d o N o r d T r u s t \ 3 - P l o t S h e e t s \ A 5 . 1 E x t e r i o r E l e v a t i o n s . d w g A5.1 Exterior Elevations A5.1 WEST ELEVATION SCALE: 1/4" = 1'-0"1 SOUTH ELEVATION SCALE: 1/4" = 1'-0"2 (N) ELEVATIONS KEYNOTES: ROOFING-BORAL STONE MOUNTAIN BLEND, LIGHTWEIGHT CONCRETE TILE. ESR-1647 and/or UES ER_04122.00 2.01 2.02 2.03 2.04 2.05 2.06 2.07 2.08 2.09 SMOOTH STUCCO FINISH GAS METER WINDOW(S) PER SCHEDULE DOOR(S) PER SCHEDULE 42" CABLE GUARDRAIL METAL STAIRCASE SCREED @ STUCCO ACRYLIC GARAGE DOOR WINDOW NOTE: HOA: AVERAGE CURB HEIGHT IS 12.55'. A CERTIFIED BUILDING HEIGHT CERTIFICATION MUST BE SUBMITTED IMMEDIATELY AFTER THE ROOF MATERIAL HAS BEEN INSTALLED. THE MEASUREMENT MUST COME FROM THE AVERAGE CURB HEIGHT OF 12.55' AND THE MAXIMUM HEIGHT CANNOT EXCEED 36.55' (24'-0”). CITY: AVERAGE GRADE OF THE NEW STRUCTURE CORNERS IS 11.93'. A CERTIFIED BUILDING HEIGHT CERTIFICATION MUST BE SUBMITTED IMMEDIATELY AFTER THE ROOF MATERIAL HAS BEEN INSTALLED. THE MEASUREMENT MUST COME FROM THE AVERAGE FINISH GRADE OF 11.93' AND THE MAXIMUM HEIGHT CANNOT EXCEED 40.93'' (29'-0”). 12.01'+12.50'+10.48'+12.74'=47.73' 47.73'/4= 11.93' CITY AVERAGE = CITY ESTABLISHED GRADE = FINISH GRADE AVERAGE 30'X18' WHITE ROLL-UP DOOR BEYOND MATCH 940 VIA LIDO 2.10 EAVES AND RAKES 2.11 WHITE BOARD AND BATTEN SIDING ON SECTIONAL GARAGE DOOR 2.12 SECTIONAL GARAGE DOOR MOUNTED ONTO 30X18 DOOR 2.13 8 IN. STUCCO TRIM 2.14 30'X18' SECTIONAL GARAGE DOOR 2.15 ELECTRICAL SERVICE METER HEIGHT CERTIFICATION REQUIRED STUCCO WRAPPED COLUMN, PER STRUCTURAL2.16 GUTTER2.17 DOWNSPOUT2.18 EXTERIOR ELEVATIONS 29 ' - 0 " 4" 19 ' - 6 3 / 4 " 12 ' - 1 0 3 / 4 " 6' - 8 1 / 2 " 29 ' - 0 " T.O. PLATE T.O. PLATE T.O. PLATE H.O.A: T.O. CURB (12.55')H.O.A: T.O. CURB (12.55') 23 ' - 9 3 / 4 " 17 ' - 9 " 12 ' - 6 3 / 4 " 23 ' - 9 3 / 4 " F.G. 12.36'F.G. 12.36' CITY OF NEWPORT BEACH 29.00'+ CITY ESTAB. GRADE (11.93')= 40.93'' NAVD88 MAX. SLOPED ROOF HEIGHT MAX. SLOPED ROOF HEIGHT MAX. PARAPET/ FLAT ROOF HEIGHT CITY OF NEWPORT BEACH 24.00'+ CITY ESTAB. GRADE (11.93)= 35.93' NAVD88 CITY OF NEWPORT BEACH 29.00'+ CITY ESTAB. GRADE (11.93')= 40.93' NAVD88 1' - 0 " 24 ' - 0 " 24 ' - 0 " CITY OF NEWPORT BEACH 24.00'+ CITY ESTAB. GRADE (11.93')= 35.93' NAVD88 MAX. PARAPET/ FLAT ROOF HEIGHT F.F. (12.70') 9'- 5 3 / 4 " 10 1 / 2 " 3'- 6 " 2'-6" 2' - 0 " 4" CITY AVG. (11.93')CITY AVG. (11.93') T.O.STRUCT. SLAB (12.70') T.O.STRUCT. SLAB (12.70') 8" COVERED PATIO COVERED PATIO B 29 ' - 0 " 4" 19 ' - 6 5 / 8 " 12 ' - 1 0 3 / 4 " 8' - 7 1 / 4 " 3'- 6 " 29 ' - 0 " T.O. PLATE T.O. PLATE H.O.A: T.O. CURB (12.55') H.O.A: T.O. CURB (12.55') 23 ' - 9 3 / 4 " 22 ' - 8 1 / 2 " F.G. 12.36'F.G. 12.36' GasMeter FINISH GRADE(48” CLR. FRONT)4'- 0 " CITY OF NEWPORT BEACH 29.00'+ CITY ESTAB. GRADE (11.93')= 40.93' NAVD88 MAX. SLOPED ROOF HEIGHT CITY OF NEWPORT BEACH 24.00'+ CITY ESTAB. GRADE (11.93')= 35.93' NAVD88 MAX. PARAPET/ FLAT ROOF HEIGHT MAX. SLOPED ROOF HEIGHT MAX. PARAPET/ FLAT ROOF HEIGHT CITY OF NEWPORT BEACH 24.00'+ CITY ESTAB. GRADE (11.93')= 35.93' NAVD88 CITY OF NEWPORT BEACH 29.00'+ CITY ESTAB. GRADE (11.93')= 40.93' NAVD88 R= 3 ' - 0 " 24 ' - 0 " 24 ' - 0 " 1' - 0 " 13 ' - 5 1 / 4 " CITY OF NEWPORT BEACH 24.00'+ CITY ESTAB. GRADE (11.93')= 35.93' NAVD88 2'-1 3/4" 1'-7 3/4" 2'-1 3/4"2'-1 3/4" 1'-7 3/4"1'-7 3/4" 11 ' - 7 3 / 4 " 20'-0 1/4"20'-0 1/4"18'-1 1/4" 6'- 4 " 3'- 0 " 5'- 1 0 " 3' - 0 " 2'- 8 " 4'- 8 " T.O. PLATE 17 ' - 8 1 / 2 " 3'-0" 2' - 0 " 8'-10 3/4" 4'- 9 1 / 2 " CITY AVG. (11.93')CITY AVG. (11.93') T.O.STRUCT. SLAB (12.70') COVERED PATIOCOVERED PATIO COVERED PATIO OPEN OPEN OPEN 1 1 1 111 2B2B2B43 2CC PLOT DATE: SCALE: DESIGN BY: DRAWN BY: CHECKED DATE: FILE NAME: SH E E T S : REVISIONS: BILL DURANT Th e 9 4 4 V i a L i d o N o r d T r u s t 94 4 V i a L i d o N o r d Ne w p o r t B e a c h , C A 9 2 6 6 3 P 562.424.8816 F 562.424.8440 STAMP: BI L L D U R A N T De s i g n e r / B u i l d e r 22 5 9 O r a n g e A v e n u e Si g n a l H i l l , C a l i f o r n i a 9 0 7 5 5 AS NOTED Z: \ P r o j e c t F o l d e r s \ P r o j e c t s - 2 0 1 8 \ 9 4 4 V i a L i d o N o r d T r u s t \ 3 - P l o t S h e e t s \ A 5 . 1 E x t e r i o r E l e v a t i o n s . d w g A5.1 Exterior Elevations BI L L D U R A N T De s i g n e r / B u i l d e r 22 5 9 O r a n g e A v e n u e Si g n a l H i l l , C a l i f o r n i a 9 0 7 5 5 July 24, 2020 RM / KC AS NOTED Z: \ P r o j e c t F o l d e r s \ P r o j e c t s - 2 0 1 8 \ 9 4 4 V i a L i d o N o r d T r u s t \ 3 - P l o t S h e e t s \ A 5 . 1 E x t e r i o r E l e v a t i o n s . d w g A5.1 Exterior Elevations A5.2 EAST ELEVATION SCALE: 1/4" = 1'-0"1 NORTH ELEVATION SCALE: 1/4" = 1'-0"2 (N) ELEVATIONS KEYNOTES: ROOFING-BORAL STONE MOUNTAIN BLEND, LIGHTWEIGHT CONCRETE TILE. ESR-1647 and/or UES ER_04122.00 2.01 2.02 2.03 2.04 2.05 2.06 2.07 2.08 2.09 SMOOTH STUCCO FINISH GAS METER WINDOW(S) PER SCHEDULE DOOR(S) PER SCHEDULE 42" CABLE GUARDRAIL METAL STAIRCASE SCREED @ STUCCO ACRYLIC GARAGE DOOR WINDOW NOTE: HOA: AVERAGE CURB HEIGHT IS 12.55'. A CERTIFIED BUILDING HEIGHT CERTIFICATION MUST BE SUBMITTED IMMEDIATELY AFTER THE ROOF MATERIAL HAS BEEN INSTALLED. THE MEASUREMENT MUST COME FROM THE AVERAGE CURB HEIGHT OF 12.55' AND THE MAXIMUM HEIGHT CANNOT EXCEED 36.55' (24'-0”). CITY: AVERAGE GRADE OF THE NEW STRUCTURE CORNERS IS 11.93'. A CERTIFIED BUILDING HEIGHT CERTIFICATION MUST BE SUBMITTED IMMEDIATELY AFTER THE ROOF MATERIAL HAS BEEN INSTALLED. THE MEASUREMENT MUST COME FROM THE AVERAGE FINISH GRADE OF 11.93' AND THE MAXIMUM HEIGHT CANNOT EXCEED 40.93'' (29'-0”). 12.01'+12.50'+10.48'+12.74'=47.73' 47.73'/4= 11.93' CITY AVERAGE = CITY ESTABLISHED GRADE = FINISH GRADE AVERAGE 30'X18' WHITE ROLL-UP DOOR BEYOND MATCH 940 VIA LIDO 2.10 EAVES AND RAKES 2.11 WHITE BOARD AND BATTEN SIDING ON SECTIONAL GARAGE DOOR 2.12 SECTIONAL GARAGE DOOR MOUNTED ONTO 30X18 DOOR 2.13 8 IN. STUCCO TRIM 2.14 30'X18' SECTIONAL GARAGE DOOR 2.15 ELECTRICAL SERVICE METER HEIGHT CERTIFICATION REQUIRED STUCCO WRAPPED COLUMN, PER STRUCTURAL2.16 GUTTER2.17 DOWNSPOUT2.18 EXTERIOR ELEVATIONS TYPICAL DOOR SCHEDULE NOTES: 1.VERIFY SLIDE / SWING OPERATION DIRECTION WITH PLANS AND ELEVATIONS. 2.HINGED DOORS OPENING INTO DWELLING UNITS SHALL BE EQUIPPED WITH APPROVED DEAD BOLTS AND LOCK SETS HAVING DEAD-LOCKING LATCHBOLTS OR SIMILAR LOCKSET DEVICE. 3.THE LOCK OR LATCH SHALL BE NO MORE THAN 48" FROM THE FLOOR. 4.PROVIDE A LANDING, FLOOR OR PORCH, THAT IS AT LEAST 36" MINIMUM IN DIRECTION OF TRAVEL (C.R.C. R311.3). 5.THE OUTSIDE LANDING OR PORCH MAY BE NO MORE THAN 8" LOWER THAN THE SIDE FLOOR LEVEL. 6.IF THE OUTSIDE FINISH LANDING ELEVATION IS LOWER THAN THE INTERIOR THE DOOR SHALL NOT SWING OUT OVER THE PORCH. 7.DOORS AND FRAMES FROM 1 HOUR RATED GARAGE TO HOUSE WALL SHALL BE RATED NOT LESS THAN 20 MINUTES WITH SMOKE CONTROL ASSEMBLY, SELF CLOSING, TIGHT FITTING, SOLID CORE WOOD DOOR OR EQUIVALENT. PER C.R.C. 302.4 (EXCEPTION 3). 8.REFER TO THIS SHEET FOR GLAZING NOTES. 9.ALL HARDWIRE AND FINISHES TO BE APPROVED BY OWNER PRIOR TO PURCHASE AND INSTALLATION. 10.EGRESS DOORS SHALL BE READILY OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT (R311.2) 11.LANDING OR FLOOR AT REQUIRED EGRESS DOOR SHALL NOT BE MORE THAN 1 12" THRESHOLD (R311.3.1). 12.DOORS TO BE SET ON CENTER OF WALLS. IN CASES OF DOUBLE-THICK WALLS, DOORS TO BE SET ON CENTER OF INNERMOST WALL. 13.“FENESTRATIONS MUST HAVE TEMPORARY AND PERMANENT LABELS.” SAFETY GLAZING TO BE PROVIDED IN THE FOLLOWING HAZARDOUS LOCATIONS: LIGHT AND VENTILATION: *EGRESS WINDOW TYPICAL WINDOW NOTES: 1. CONFORMING TO THE HUMAN IMPACT LOADS OF SECTION R308.3 AND R308.4: a.FIXED AND OPERABLE PANELS OF SWINGING, SLIDING AND BIFOLD DOOR ASSEMBLIES. b.GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT TO A DOOR WHERE THE BOTTOM EDGE IS LESS THAN 60 INCHES ABOVE THE FLOOR OR WALKING SURFACE AND IT MEETS EITHER OF THE FOLLOWING CONDITIONS: i.WHERE THE GLAZING IS WITHIN 24 INCHES OF EITHER SIDE OF THE DOOR IN THE PLANE OF THE DOOR IN A CLOSED POSITION. ii.WHERE THE GLAZING IS ON A WALL PERPENDICULAR TO THE PLANE OF THE DOOR IN A CLOSED POSITION AND WITHIN 24 INCHES OF THE HINGE SIDE OF AN IN-SWINGING DOOR. c.GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL THAT MEETS ALL OF THE FOLLOWING CONDITIONS: i.EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 SQUARE FEET. ii.BOTTOM EDGE LESS THAN 18 INCHES ABOVE THE FLOOR. iii.TOP EDGE GREATER THAN 36 INCHES ABOVE THE FLOOR. iv.ONE OR MORE WALKING SURFACES WITHIN 36 INCHES HORIZONTALLY OF THE GLAZING. d.GLAZING IN RAILINGS. e.GLAZING IN ENCLOSURES FOR OR WALLS FACING HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATHTUBS AND SHOWERS WHERE THE BOTTOM EDGE OF THE GLAZING IS LESS THAN 60 INCHES MEASURED VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE. f.GLAZING ADJACENT TO STAIRWAYS, LANDINGS AND RAMPS WITHIN 36 INCHES HORIZONTALLY OF A WALKING SURFACE WHEN THE SURFACE OF THE GLAZING IS LESS THAN 36 INCHES ABOVE THE PLANE OF THE ADJACENT WALKING SURFACE. FENESTRATIONS MUST HAVE TEMPORARY AND PERMANENT LABELS. REFER TO AD.1 FOR WINDOW FLASHING DETAIL, TYP. VERIFY SLIDE / SWING OPERATION DIRECTION WITH PLANS AND ELEVATIONS. SLEEPING ROOMS MUST BE PROVIDED WITH A MEANS TO EXIT DIRECTLY TO THE OUTSIDE IN CASE OF FIRE. EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL BE CLEAR OF ANY OBSTRUCTION AND OPERATIONAL FROM THE INSIDE OF THE ROOM WITHOUT THE USE OF KEYS, TOOLS, OR SPECIAL KNOWLEDGE (R310.1.1). WINDOWS MUST BE LARGE ENOUGH TO LET OCCUPANTS ESCAPE AND FIREMEN TO CLIMB IN. WINDOWS MUST HAVE A NET CLEAR OPENING OF AT LEAST 5.7 SQ. FT. WITH A MINIMUM NET CLEAR HEIGHT OF 24" AND MINIMUM NET CLEAR WIDTH OF 20" THE FINISHED SILL HEIGHT MAY NOT EXCEED 44". BARS, GRILLS, COVERS, AND SCREENS PLACED OVER EMERGENCY ESCAPE AND RESCUE OPENINGS, BULKHEAD ENCLOSURES, OR WINDOW WELLS SHALL COMPLY WITH SECTION R310.4. 23.SINGLE- AND MULTIPLE-STATION SMOKE ALARMS SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS (R314.3): A.IN EACH SLEEPING ROOM B.OUTSIDE OF EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. C.ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDING BASEMENTS AND HABITABLE ATTICS, BUT NOT INCLUDING CRAWL SPACES AND UNINHABITABLE ATTICS. D.SMOKE ALARMS SHALL BE INSTALLED NOT LESS THAN 3 FEET HORIZONTALLY FROM THE DOOR OR OPENING OF A BATHROOM THAT CONTAINS A BATHTUB OR SHOWER UNLESS THIS WOULD PREVENT PLACEMENT OF A SMOKE ALARM REQUIRED BY SECTION R314.3 2.SMOKE ALARMS SHALL BE HARDWIRED WITH BATTERY BACKUP AND ALARMS INTERCONNECTED (R314.4). 3.BATTERY OPERATED SMOKE ALARMS ARE PERMITTED IN LIEU OF INTERCONNECTION / HARD-WIRING OF SMOKE ALARMS IN EXISTING AREAS WHERE THE CONSTRUCTION DOES NOT INVOLVE THE REMOVAL OF INTERIOR FINISHES (R314.4). 1.EQUIP HABITABLE ROOMS WITH GLAZED WINDOWS FOR NATURAL LIGHT WITH A MINIMUM OF 1 8 OR THE FLOOR AREA OF THE ROOM OR 8 SQ. FT., WHICHEVER IS LARGER. 2.EQUIP HABITABLE ROOMS WITH OPENABLE WINDOWS WITH A MINIMUM AREA OF 1 16 OF THE FLOOR AREA OR 4 SQ. FT., WHICHEVER IS LARGER. 3.EQUIP BATHROOMS WITH OPENABLE WINDOWS WITH A MINIMUM AREA OF 1 20 OF THE FLOOR AREA OR 1 1 2" SQ. FT., WHICHEVER IS LARGER. IF OPENABLE WINDOWS ARE NOT PROVIDED THEN THE MECHANICAL VENTILATION MUST BE PROVIDED AS DETAILED IN THE C.R.C. WINDOW CONTROL OPENING DEVICE SHALL NOT REDUCE THE REQUIRED NET CLEAR OPENING AREA OF THE WINDOW R 312.2.2. DOOR AND WINDOW NOTES: STATIONARY1 VA R I E S , R E F E R T O E X T E R I O R E L E V A T I O N S CASEMENT2 6'- 8 " 2'- 8 " AWNING5 4'- 8 " 6'- 8 " CASEMENT2B 6'- 8 " 2'- 8 " MULLED CASEMENT3 6'- 8 " 2'- 8 " MULLED CASEMENT4 6'- 8 " 2'- 8 " MULLED STATIONARY6 4" WINDOW SCHEDULE A7.1 DOOR SCHEDULE DOOR AND FRAME SCHEDULE MARK WD.HGT.THK. SIZE MATL.GLAZING STYLE DOOR FIRE RATING LABEL U-FACTOR SHGC FENESTRATION/ GLAZING NOTES WINDOW SCHEDULE MARK WIDTH HEIGHT SIZE TYPE MATERIAL GLAZING NOTESTEMPERED GLAZING WINDOW ELEVATIONS QTY. QTY. HEAD JAMB THRES. DETAIL U-FACTOR SHGC TYPICAL DOOR SCHEDULE NOTES: DOOR NOTES WINDOW NOTES PLOT DATE: SCALE: DESIGN BY: DRAWN BY: CHECKED DATE: FILE NAME: SH E E T S : REVISIONS: BILL DURANT Th e 9 4 4 V i a L i d o N o r d T r u s t 94 4 V i a L i d o N o r d Ne w p o r t B e a c h , C A 9 2 6 6 3 P 562.424.8816 F 562.424.8440 STAMP: BI L L D U R A N T De s i g n e r / B u i l d e r 22 5 9 O r a n g e A v e n u e Si g n a l H i l l , C a l i f o r n i a 9 0 7 5 5 AS NOTED Z: \ P r o j e c t F o l d e r s \ P r o j e c t s - 2 0 1 8 \ 9 4 4 V i a L i d o N o r d T r u s t \ 3 - P l o t S h e e t s \ A 7 . 1 D O O R A N D W I N D O W S C H E D U L E . d w g A7.1 DOOR AND WINDOW SCHEDULE BI L L D U R A N T De s i g n e r / B u i l d e r 22 5 9 O r a n g e A v e n u e Si g n a l H i l l , C a l i f o r n i a 9 0 7 5 5 July 24, 2020 RM / KC AS NOTED Z: \ P r o j e c t F o l d e r s \ P r o j e c t s - 2 0 1 8 \ 9 4 4 V i a L i d o N o r d T r u s t \ 3 - P l o t S h e e t s \ A 7 . 1 D O O R A N D W I N D O W S C H E D U L E . d w g A7.1 DOOR AND WINDOW SCHEDULE A 28'-10"17'-9"METAL SECTIONAL --1 1 3/8"-- C 2 6'-8"3'-0"1 3/8" ROLL-UP TEMPERED --- 2 2 9 1 2 4'-0" 2'-0" 4'-0" 3'-0"3'-0" 2'-0" 3'-0" 2'-0" 1'-6" 2'-0" DUAL DUAL DUAL DUAL DUAL -- -- -- -- -- AWNING STATIONARY SLIDER CASEMENT NO NO YES NO NO 2 3 4 1 5 1.VERIFY SLIDE / SWING OPERATION DIRECTION WITH PLANS AND ELEVATIONS. 2.HINGED DOORS OPENING INTO DWELLING UNITS SHALL BE EQUIPPED WITH APPROVED DEAD BOLTS AND LOCK SETS HAVING DEAD-LOCKING LATCHBOLTS OR SIMILAR LOCKSET DEVICE. 3.THE LOCK OR LATCH SHALL BE NO MORE THAN 48" FROM THE FLOOR. 4.PROVIDE A LANDING, FLOOR OR PORCH, THAT IS AT LEAST 36" MINIMUM IN DIRECTION OF TRAVEL (C.R.C. R311.3). 5.THE OUTSIDE LANDING OR PORCH MAY BE NO MORE THAN 8" LOWER THAN THE SIDE FLOOR LEVEL. 6.IF THE OUTSIDE FINISH LANDING ELEVATION IS LOWER THAN THE INTERIOR THE DOOR SHALL NOT SWING OUT OVER THE PORCH. 7.DOORS AND FRAMES FROM 1 HOUR RATED GARAGE TO HOUSE WALL SHALL BE RATED NOT LESS THAN 20 MINUTES WITH SMOKE CONTROL ASSEMBLY, SELF CLOSING, TIGHT FITTING, SOLID CORE WOOD DOOR OR EQUIVALENT. PER C.R.C. 302.4 (EXCEPTION 3). 8.REFER TO THIS SHEET FOR GLAZING NOTES. 9.ALL HARDWIRE AND FINISHES TO BE APPROVED BY OWNER PRIOR TO PURCHASE AND INSTALLATION. 10.EGRESS DOORS SHALL BE READILY OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT (R311.2) 11.LANDING OR FLOOR AT REQUIRED EGRESS DOOR SHALL NOT BE MORE THAN 1 1 2" THRESHOLD (R311.3.1). 12.DOORS TO BE SET ON CENTER OF WALLS. IN CASES OF DOUBLE-THICK WALLS, DOORS TO BE SET ON CENTER OF INNERMOST WALL. 13.“FENESTRATIONS MUST HAVE TEMPORARY AND PERMANENT LABELS.”SAFETY GLAZING TO BE PROVIDED IN THE FOLLOWING HAZARDOUS LOCATIONS: LIGHT AND VENTILATION:*EGRESS WINDOW TYPICAL WINDOW NOTES: 1. CONFORMING TO THE HUMAN IMPACT LOADS OF SECTION R308.3 AND R308.4: a.FIXED AND OPERABLE PANELS OF SWINGING, SLIDING AND BIFOLD DOOR ASSEMBLIES. b.GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT TO A DOOR WHERE THE BOTTOM EDGE IS LESS THAN 60 INCHES ABOVE THE FLOOR OR WALKING SURFACE AND IT MEETS EITHER OF THE FOLLOWING CONDITIONS: i.WHERE THE GLAZING IS WITHIN 24 INCHES OF EITHER SIDE OF THE DOOR IN THE PLANE OF THE DOOR IN A CLOSED POSITION. ii.WHERE THE GLAZING IS ON A WALL PERPENDICULAR TO THE PLANE OF THE DOOR IN A CLOSED POSITION AND WITHIN 24 INCHES OF THE HINGE SIDE OF AN IN-SWINGING DOOR. c.GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL THAT MEETS ALL OF THE FOLLOWING CONDITIONS: i.EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 SQUARE FEET. ii.BOTTOM EDGE LESS THAN 18 INCHES ABOVE THE FLOOR. iii.TOP EDGE GREATER THAN 36 INCHES ABOVE THE FLOOR. iv.ONE OR MORE WALKING SURFACES WITHIN 36 INCHES HORIZONTALLY OF THE GLAZING. d.GLAZING IN RAILINGS. e.GLAZING IN ENCLOSURES FOR OR WALLS FACING HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATHTUBS AND SHOWERS WHERE THE BOTTOM EDGE OF THE GLAZING IS LESS THAN 60 INCHES MEASURED VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE. f.GLAZING ADJACENT TO STAIRWAYS, LANDINGS AND RAMPS WITHIN 36 INCHES HORIZONTALLY OF A WALKING SURFACE WHEN THE SURFACE OF THE GLAZING IS LESS THAN 36 INCHES ABOVE THE PLANE OF THE ADJACENT WALKING SURFACE. FENESTRATIONS MUST HAVE TEMPORARY AND PERMANENT LABELS. REFER TO AD.1 FOR WINDOW FLASHING DETAIL, TYP. VERIFY SLIDE / SWING OPERATION DIRECTION WITH PLANS AND ELEVATIONS. SLEEPING ROOMS MUST BE PROVIDED WITH A MEANS TO EXIT DIRECTLY TO THE OUTSIDE IN CASE OF FIRE. EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL BE CLEAR OF ANY OBSTRUCTION AND OPERATIONAL FROM THE INSIDE OF THE ROOM WITHOUT THE USE OF KEYS, TOOLS, OR SPECIAL KNOWLEDGE (R310.1.1). WINDOWS MUST BE LARGE ENOUGH TO LET OCCUPANTS ESCAPE AND FIREMEN TO CLIMB IN. WINDOWS MUST HAVE A NET CLEAR OPENING OF AT LEAST 5.7 SQ. FT. WITH A MINIMUM NET CLEAR HEIGHT OF 24" AND MINIMUM NET CLEAR WIDTH OF 20" THE FINISHED SILL HEIGHT MAY NOT EXCEED 44". BARS, GRILLS, COVERS, AND SCREENS PLACED OVER EMERGENCY ESCAPE AND RESCUE OPENINGS, BULKHEAD ENCLOSURES, OR WINDOW WELLS SHALL COMPLY WITH SECTION R310.4. 23.SINGLE- AND MULTIPLE-STATION SMOKE ALARMS SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS (R314.3): A.IN EACH SLEEPING ROOM B.OUTSIDE OF EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. C.ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDING BASEMENTS AND HABITABLE ATTICS, BUT NOT INCLUDING CRAWL SPACES AND UNINHABITABLE ATTICS. D.SMOKE ALARMS SHALL BE INSTALLED NOT LESS THAN 3 FEET HORIZONTALLY FROM THE DOOR OR OPENING OF A BATHROOM THAT CONTAINS A BATHTUB OR SHOWER UNLESS THIS WOULD PREVENT PLACEMENT OF A SMOKE ALARM REQUIRED BY SECTION R314.3 2.SMOKE ALARMS SHALL BE HARDWIRED WITH BATTERY BACKUP AND ALARMS INTERCONNECTED (R314.4). 3.BATTERY OPERATED SMOKE ALARMS ARE PERMITTED IN LIEU OF INTERCONNECTION / HARD-WIRING OF SMOKE ALARMS IN EXISTING AREAS WHERE THE CONSTRUCTION DOES NOT INVOLVE THE REMOVAL OF INTERIOR FINISHES (R314.4). 1.EQUIP HABITABLE ROOMS WITH GLAZED WINDOWS FOR NATURAL LIGHT WITH A MINIMUM OF 1 8 OR THE FLOOR AREA OF THE ROOM OR 8 SQ. FT., WHICHEVER IS LARGER. 2.EQUIP HABITABLE ROOMS WITH OPENABLE WINDOWS WITH A MINIMUM AREA OF 1 16 OF THE FLOOR AREA OR 4 SQ. FT., WHICHEVER IS LARGER. 3.EQUIP BATHROOMS WITH OPENABLE WINDOWS WITH A MINIMUM AREA OF 1 20 OF THE FLOOR AREA OR 1 12" SQ. FT., WHICHEVER IS LARGER. IF OPENABLE WINDOWS ARE NOT PROVIDED THEN THE MECHANICAL VENTILATION MUST BE PROVIDED AS DETAILED IN THE C.R.C. WINDOW CONTROL OPENING DEVICE SHALL NOT REDUCE THE REQUIRED NET CLEAR OPENING AREA OF THE WINDOW R 312.2.2. WOOD/ ALUMINUM CLAD WOOD/ ALUMINUM CLAD WOOD/ ALUMINUM CLAD WOOD/ ALUMINUM CLAD WOOD/ ALUMINUM CLAD B 1 1 3/8"METAL GLASS PANEL ---- 1 RIGHT HINGE, 1 LEFT HINGE 4 9/16" 4 9/16" 4 9/16" 4 9/16" 4 9/16" NOTE: ALL HARDWARE TO BE NON-CORROSIVE STAINLESS STEEL, BRONZE, OR COPPER ONLY. 0.3 0.23 0.3 0.23 0.3 0.23 0.3 0.23 0.3 0.23AWNING 3 4'-0"4'-0"DUAL --CASEMENT NO2BWOOD/ ALUMINUM CLAD 4 9/16"0.3 0.23 SWING RIGHT RIGHT WOOD 28'-10"17'-9" 10 3 1 7/8" THICK 3-COAT EXTERIOR PLASTER: 1/8" THICK COLOR COAT OVER 3/8" THICK BROWN COAT OVER 3/8" SCRATCH COAT WITH EMBEDDED METAL LATH. INSTALLED PER MANUFACTURER'S SPECIFICATIONS. PLYWOOD SHEATHING, WHERE OCCURS (REFER TO STRUCTURAL DRAWINGS) BATT WALL INSULATION, WHERE OCCURS (REFER TO TITLE-24 CALCULATIONS) TWO LAYERS OF GRADE 'D' BUILDING PAPER LAPPED IN SHINGLE METHOD. INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 2X STUD WALL FRAMING AT MAX. 24" O.C. - REFER TO STRUCTURAL DRAWINGS PLASTER SHALL HAVE A SMOOTH STEEL TROWEL FINISH AND BE PAINTED. PROVIDE ANTI-CRACK SUPRESSANT MEMBRANE OVER PLASTER BROWN COAT 15" TO TOP OF DRAFT STOP BLOCKING MINIMUM 2X6 PLUMBING WALL 2X6 FLAT BLOCKING OVER DRAFT STOP BLOCKING 2X6 FLAT DRAFT STOP BLOCKING TACK 2X4 LEDGER ON FOR PLUMBER TO INSTALL CHECK MANUFACTURE'S INSTALLATION INSTRUCTIONS INCLUDING ROUGH-IN DIMENSIONS FOR EXACT MEASUREMENTS & SPECIFIC INSTALLATION REQUIREMENTS FLAT STUD BACKING FOR TUB ENCLOSURE FLAT STUD BACKING FOR TILE / GYP. BD. TRANSITION 4" MIN. OPENING IN FLOOR, BOTH SIDES 8X12 MIN. OPENING IN FLOOR Step 1 QUICK SETTING CEMENT OVER 30 LB. FELT 1. SET TUB LEDGER LEVEL AT THE MANUFACTURER'S RECOMMENDED HEIGHT AND NAIL FIRMLY TO WALL FRAMING STUDS. 2. PLACE TUB IN SPACE AND CHECK FIT, ALIGNMENT AND LEVEL 3. USE 30 LB. FELT ON SUBFLOOR AND APPLY A LIBERAL AMOUNT OF QUICK SETTING CEMENT WHERE BOTTOM OF TUB WILL SET. 4. SET TUB INTO CEMENT AND TIGHT AGAINST LEDGER CHECK LEVEL AT ALL SIDES AND FASTEN WITH GALVANIZED OR STAINLESS STEEL SCREWS OR NAILS ALWAYS REFER TO TUB MANUFACTURER'S INSTALLATION INSTRUCTIONS. COMPLETE ALL PREPARATION NEEDED PRIOR TO TUB BED SETTING. THIS MAY INCLUDE PRE-INSPECTIONS AND PRE- LIMINARY INSULATION, STRUCTURAL SHEAR PANELS AND FIRE AND SOUND RATED WALL COVERING INSTALL 12" BITUMEN ON ALL INSIDE CORNERS INSTALL BITUMEN OVER TUB FLANGE / NAILING FIN AND EXTEND MIN. 6" PAST TUB FRONT APPLY BLOB OF CAULKING AS FINISHING TOUCH TO FLASHING INSTALLATION 12" WIDE BITUMEN MEMBRANE SLID BEHIND TUB AT FRONT SKIRT AND BACK TO TUB FLANGE / NAILING FIN AS FAR AS POSSIBLE CAULK PENETRATION AT SPOUT STUB-OUT APPLY A MIN 3/8"-1/2" BEAD OF FUTUREFLASH PRO-INSTALLER CAULK AT TUB FRONT SKIRT AND AT TOP EDGE OF TUB FLANGE / NAILING FIN. EXTEND CAULK 6" PAST EDGE OF TUB Step 2 Step 3 Step 4 Step 5 FORTIFIBER AQUABAR CLASS 'B' PAPER FASTENED WITH GALVANIZED STAPLES OVER 18 GA. GALVANIZED LINE WIRE SPACED 6" O.C. MAXIMUM, WITH GALVANIZED NAILS. INSTALL (2) LAYER BOTTOM COURSE FOLLOWED BY (2) LAYER UPPER COURSE WITH A MINIMUM OVERLAP OF 3" RUN OUT PAPER AT LEAST 6" BEYOND TUB EDGE INSTALL 18 GA. GALVANIZED BACKING LINE WIRE OVER 6" O.C. GALVANIZED NAILS REMOVE MUD RING BEFORE INSTALLING AQUABAR PAPER CUT PAPER TIGHT TO VALVE SPOUT AND SHOWER HEAD STUB OUTS AND CAULK AROUND PENETRATIONS THEN RE-INSTALL MUD RING TRANSITION FROM LATH TO DRYWALL 37 1/2"-38" FOR 36" TUBS AND 86" ABOVE FLOOR W/ TILE @ 90 DEGREES MIN. 18ga GALVANIZED WOVEN WIRE LATH (STUCCO NETTING NAILED WITH FURRING NAILS TO STUDS AT 6" O.C MIN. 3" WIRE LAP STUCCO NETTING MAY BE APPLIED BEFORE OR AFTER DRYWALL AQUABAR MUST BE INSTALLED BEFORE DRYWALL CAULK ANY TEARS IN PAPER AND AROUND VALVE AND STUDS AFTER NAILING OFF 1 1/2" X17" GALVANIZED EXPANDED METAL LATH (DIAMOND MESH) AT TUB SKIRT +2 6 " SP O U T +3 4 " VA L V E +8 4 " T O SH O W E R H E A D +8 6 " 36" MIN. 18" MIN. * STUCCO FINISH SCALE: NONE EXHAUST PORT CONNECTION ELEVATION SECTION DRYER VENT CONNECTION 22 GAUGE METALIZED STEEL INSERT WITH VENT AND GAS LINE KNOCKOUTS IN ONE BOX 21" X 12 12" DRYER BOX RECESSED INSIDE 2X6 STUD WALL TUB FLASHING INSTALLATION SCALE: NONE SCALE: 3" = 1'-0" 9SCALE: 3" = 1'-0" 8 2SCALE: 3" = 1'-0"WALL PENETRATION @ WOOD FRAME 4SCALE: 3" = 1'-0" 5SCALE: 3" = 1'-0" 6SCALE: 3" = 1'-0" 7SCALE: 3" = 1'-0" CONTINUOUS APPROVED SELF ADHERING RUBBERIZED MEMBRANE & BUILDING PAPER. SEE DETAILS 2/D1.3 & 11/D1.3 FOR ADDITIONAL INFO. (PROVIDE 2 X BLOCKING BEHIND, WHERE NEEDED FOR SECURE ATTACHMENT TO WALL) TILE OR STONE OVER MORTAR SETTING BED, LATH SLOPE AND FORTIFIBER "AQUABAR" CLASS B PAPER PROVIDE PLYWOOD BACKING BEHIND SHOWER AND TUB RECESSES TO ACCEPT PAPER AND LATH SLOPE SHELF 1/4" PER FOOT TO DRAIN 2X BLOCKING 2X SOLID BACKING 2X BLOCKING 2X SOLID BACKING SHOWER SHAMPOO NICHE FIRE SEPARATION FLOOR/CEILING SHOWER CURB TUB FILLER AT TUB FRAME PLUMBING ISOLATION CONCRETE FLOOR3 1/2" WATERPROOFING OVER CURB MOPPED WATERPROOFING MEMBRANE. CONTINUE CORROSION-RESISTANT METAL LATH OVER HOT (4) 2X4 CURB HARDSURFACE MATERIAL PER INTERIOR DESIGNER TILE OR STONE OVER MORTAR SETTING BED OR SLOPE TO DRAIN WALL BEYOND 6" FI N I S H SLOPE SLOPE TO DRAIN STONE DECK ON CEMENT BOARD TUB FILLER / FAUCET TRANSFER VALVE / FAUCET CONNECTION KEEP OPENING CLEAR OF VERTICAL FRAMING AND TOP PLATE ACCOMODATE 1 3/4" LONG VALVE HEAD CUT BACK PLYWOOD & FRAME OPENING TO *** DECK MOUNTED TUB PER SPECIFICATION AND OWNER SELECTION GENERAL NOTES *SEAL ALL TYVEK®JOINTS AND PENETRATIONS WITH APPROVED TAPE. (ex. DUPONT™ CONTRACTOR TAPE) *FASTEN TYVEK®TO SHEATHING WITH LARGE HEAD NAILS OR USE NAILS WITH LARGE PLASTIC WASHER HEADS. (ex. DUPONT™ WRAPCAPS) *LOCAL LAWS, ZONING, AND BUILDING CODES VARY AND THEREFORE GOVERNS OVER MATERIAL SELECTION AND DETAILING SHOWN BELOW. *INSTALL STUCCO ACCORDING TO MANUFACTURER'S WRITTEN INSTRUCTIONS TYPICAL WALL FINISH COAT BROWN COAT SCRATCH COAT WIRE LATH WEATHER RESISTIVE BARRIER (TYVEK® TYVEK® HOMEWRAP® STUCCOWRAP® SHEATHING 2"x6" WOOD STUDS w/ R-19 BATT INSULATION VAPOR RETARDER 1/2" GYPSUM BOARD PENETRATION PROVIDE WOOD BLOCKING & SEAL AROUND PENETRATION WITH MINIMALLY EXPANDING POLYURETHANE FOAM OR APPROVED CAULK (ex. EXHAUST VENT) CAULKING FLANGE (SEALED TO PENETRATION) SEAL/TAPE TYVEK® TO FLANGE (USE TYVEK® RECOMMENDED) FLEXWRAP™ FOR LARGE OPENINGS) 1 2 SILL PLATE ACOUSTICAL SEALANT BETWEEN PIPE AND FRAMING MEMBERS (1/4" CLR. ALL AROUND) scale: 6"=1'-0"scale: 3"=1'-0" 3 ref. PLUMB01 1 ISOLATE ALL PLUMBING LINES FROM FRAMING MEMBERS W/ 1/4" THICK COLLARS OF APPROVED, RESILIENT SOFT POINTS OF ATTACHMENTS MATERIALS AT ALL 2 3 FRAMING MEMBER PLUMBING LINE 3 scale: 3"=1'-0" 2 3 ref. PLUMB03 ACOUSTICAL SEALANT AT ALL PENETRATIONS THRU GYPSUM BOARD- CUT OVERSIZED HOLE TO ACCOMODATE 1/4" BEAD OF CAULKING ISOLATION RESILIENT BETWEEN PIPE RESILIENT PAD AND SUPPORT PIPE SUPPORT scale: 3"=1'-0" 1 RIGID PIPE SUPPORT 2 RIGID FRAMING MEMBERS 1 CUT OVERSIZE HOLES AT ALL PIPE PENETRA- TIONS THRU. RIGID FRAMING MEMBERS 3 PROVIDE RESILIENT ISOLATION BETWEEN PIPING AND RIGID FRAMING MEMBERS A BD C (Private Garage) (Dwelling/Habitable Room) R-3 Occupancy U-1 Occupancy 1/2" PLYWOOD SUBFLOOR MIN. 2X FLOOR FRAMING PER STRUCT'L R-__ BATT INSULATION PER T-24 (2) LAYERS 5/8" TYPE 'X' GYPSUM BOARD, FACE LAYER JOINTS OFFSET 24" FROM BASE LAYER JOINTS. TYPICAL AT OCCUPANCY SEPARATION PER CODE. 58" TYPE 'X' GYPSUM BOARD MIN. TYP. AT OCCUPANCY SEPARATION PER CODE. (LAP 12" MIN. AT WALL BASE) ONE HOUR FIRE RATED WALL ASSEMBLY PER UBC TABLE 7-B 18-1.3 &17-1.3 SCALE: 3" = 1'-0"CONCRETE-ENCASED GROUNDING 2" M I N . DIRECT CONTACT W/ EARTH SCALE: 3/4"=1'-0" 20'-0" MIN. GROUNDING ELECTRODE GROUNDING ELECTRODE CONDUCTOR NON-METALLIC SLEEVE GROUNDING CLAMP #4 AWG OR LARGER BARE COPPER CONDUCTOR OR STEEL REINFORCING BAR OR ROD NOT LESS THAN 1/2" DIA. DEVICE CONCRETE FOUNDATION NOTES: 1.) CONCRETE-ENCASED GROUNDING SHALL COMPLY W/ CEC, SEC. 250 & OTHER APPLICABLE CODES; 2.) GROUNDING CLAMPS SHALL BE LISTED FOR THE MATERIALS OF THE GROUNDING ELECTRODE & THE GROUNDING ELECTRODE CONDUCTOR & WHERE USED ON PIPE, ROD OR OTHER BURIED ELECTRODES SHALL BE LISTED FOR DIRECT SOIL BURIAL; 3.) NOT MORE THAN ONE CONDUCTOR SHALL BE CONNECTED TO THE GROUNDING ELECTRODE BY A SINGLE CLAMP OR FITTING UNLESS THE CLAMP OR FITTING IS LISTED FOR MULTIPLE CONDUCTORS; 4.) GROUNDING CLAMPS SHALL COMPLY WITH CEC 250-70. GROUNDING ELECTRODE CONDUCTOR DOES NOT HAVE TO BE LARGER THAN #4 COPPER (CEC TABLE 250-66) PLOT DATE: SCALE: DESIGN BY: DRAWN BY: CHECKED DATE: FILE NAME: SH E E T S : REVISIONS: BILL DURANT Th e 9 4 4 V i a L i d o N o r d T r u s t 94 4 V i a L i d o N o r d Ne w p o r t B e a c h , C A 9 2 6 6 3 P 562.424.8816 F 562.424.8440 STAMP: BI L L D U R A N T De s i g n e r / B u i l d e r 22 5 9 O r a n g e A v e n u e Si g n a l H i l l , C a l i f o r n i a 9 0 7 5 5 AS NOTED Z: \ P r o j e c t F o l d e r s \ P r o j e c t s - 2 0 1 8 \ 9 4 4 V i a L i d o N o r d T r u s t \ 3 - P l o t S h e e t s \ D e t a i l s . d w g Details BI L L D U R A N T De s i g n e r / B u i l d e r 22 5 9 O r a n g e A v e n u e Si g n a l H i l l , C a l i f o r n i a 9 0 7 5 5 July 24, 2020 RM / KC AS NOTED Z: \ P r o j e c t F o l d e r s \ P r o j e c t s - 2 0 1 8 \ 9 4 4 V i a L i d o N o r d T r u s t \ 3 - P l o t S h e e t s \ D e t a i l s . d w g Details DETAILS AD.1 TYPICAL/MISC. 1 1/2"2 1/2" 7 1 / 4 " 1 1 / 2 " 5 1 / 4 " 2"1 1/2" ROOF SLATE SHINGLES OVER TWO LAYERS OF 30 LB. ROOFING FELT UNDERLAYMENT PLYWOOD ROOF SHEATHING (PER STRUCTURAL DWGS.) ONE LAYER OF 72 POUND MINERAL-SURFACED, NONPERFORATED CAP SHEET COMPLYING WITH ASTM D 3909 1.75X7.25 M/L ROOF RAFTERS (PER STRUCT'L DWGS.) FOAM ANTI-PONDING STRIP 1X3 STARTER BOARD LAP ROOFING UNDERLAYMENT OVER FLASHING FLANGE CORROSION-RESISTANT METAL EDGE FLASHING 2X8 BLOCKING 2X4 BLOCKING 40 mil SELF-ADHERED ELASTOMERIC MEMBRANE FROM BEHIND PLASTER STOP AND LAP 6" MIN. OVER FIRST LAYER OF GRADE 'D' BUILDING PAPER BATT INSULATION (PER TITLE 24 REPORT) 5/8" TYPE 'X' GYPSUM BOARD PLYWOOD SHEATHING (PER STRUCTURAL DRAWINGS) 2X6 EXTERIOR STUD WALL FRAMING 22" WIDE CORROSION RESISTANT METAL VALLEY FLASHING WITH 1" MN. "V" CRIMP - SHALL NOT BE LESS THAN 0.019 INCH THICKNESS SECURE VALLEY FLASHING W/ CLIPS OF SIMILAR OR COMPATIBLE MATERIAL WITH METAL SQUARE HEAD ROOFING NAILS, SECURE AT 24" O.C. (DO NOT NAIL THROUGH VALLEY FLASHING) ONE LAYER OF 72 POUND MINERAL- SURFACED NONPERFORATED CAP SHEET COMPLYING WITH ASTM D 3909 MIN. 36" WIDE SWEAT SHEET OF 30# UNDERLAYMENT FELT UNDER ROOFING FELT RUNNING THE FULL LENGTH OF THE VALLEY PLYWOOD ROOF SHEATHING (PER STRUCTURAL DWGS.) ROOF SLATE SHINGLES OVER TWO LAYERS OF 30 LB. ROOFING FELT UNDERLAYMENT 1.75 x 7.25 M/L RAFTERS (PER STRUCT'L DWGS) ONE LAYER OF 72 POUND MINERAL-SURFACED, NONPERFORATED CAP SHEET COMPLYING WITH ASTM D 3909 PLYWOOD ROOF SHEATHING (PER STRUCTURAL DWGS.) RIDGE SLATE SHINGLE PROVIDE ONE 12" WIDE LAYER 40 mil SELF ADHERED MEMBRANE UNDER NAILER ROOF SLATE SHINGLE OVER TWO LAYERS OF 30 LB. ROOFING FELT UNDERLAYMENT SEALER STRIP - PER ROOFING MANUFACTURER'S SPECIFICATIONS 2X ROOF RAFTERS RIDGE/HIP BEAM (DBL. M/L PER STRUCTURAL) 7SCALE: 3" = 1'-0" 8SCALE: 3" = 1'-0" 9SCALE: 3" = 1'-0" 10SCALE: 3" = 1'-0"- DECK COATING "DEX-O-TEX" (PER FLOOR PLAN) OVER 1/2" EXTERIOR GRADE PLYWOOD, TYPICAL 7/8" EXTERIOR PLASTER OVER (2) LAYERS GRADE 'D' PAPER BACKED METAL LATH DECK JOISTS (PER STRUCTURAL DRAWINGS) 2" 2 1 / 2 " 2" 2x WOOD STUDS (PER STRUCTURAL DRAWINGS) FLOOR FRAMING (PER STRUCTURAL DRAWINGS) GALVANIZED "Z" BAR SCREED FLASHING WEEP SCREED @ DECK CORROSION-RESISTANT WEEP SCREED 2" MI N . 6" 8" MI N . FINISH GRADE PLASTER FINISH COAT OVER FACE OF CONCRETE SLAB/FOOTING 2x6 P.T.D.F. SILL PLATE PROVIDE PLYWOOD SHEAHTHING BEHIND SCREED AT AREAS WITHOUT SHEAR PANELS TO MATCH THICKNESS OF SHEAR PANELS, TYP. CONT. 12" STRIP OF SELF-ADHERED MEMBRANE - LAP OVER SCREED FLANGE (PROVIDE BLOCKING AS REQUIRED FOR SOLID BACKING) BATT INSULATION (PER TITLE 24 REPORT) LAP GRADE 'D' PAPER OVER SCREED FLANGE FINISH FLOORING (OR EQUAL) AND 1/2" EXTERIOR GRADE PLYWOOD TWO LAYERS GRADE 'D' BUILDING PAPER 7/8" EXTERIOR PLASTER OVER METAL LATH, 5/8" TYPE 'X' GYPSUM BOARD 2X6 EXTERIOR STUD WALL FRAMING CONCRETE FOUNDATION (PER STRUCTURAL DRAWINGS) WEEP SCREED @ GRADE 1 2 3 SCALE: 3" = 1'-0" SCALE: 3" = 1'-0" SCALE: 3" = 1'-0" EAVE DETAIL TYPICAL VALLEY FLASHING 4SCALE: 3" = 1'-0" TYPICAL RIDGE/HIP 5SCALE: 3" = 1'-0" 6SCALE: 3" = 1'-0" 7 8 9 SCALE: 3" = 1'-0" 4SCALE: 3" = 1'-0" SCALE: 3" = 1'-0" CATHEDRAL CLG. DETAIL 11SCALE: 3" = 1'-0" 7 1 / 4 " 1 1 / 2 " 5 1 / 4 " 2"2"1 1/2" ROOF SLATE SHINGLES OVER TWO LAYERS OF 30 LB. ROOFING FELT UNDERLAYMENT ONE LAYER OF 72 POUND MINERAL-SURFACED, NONPERFORATED CAP SHEET COMPLYING WITH ASTM D 3909 1.75 X 7.25 M/L ROOF RAFTERS (PER STRUCTURAL DWGS.) PLYWOOD ROOF SHEATHING (PER STRUCTURAL DWGS.) 2 1/2"1 1/2" RIGID INSULATION PER T-24 EXTERIOR BALCONY DRAIN BOX 4" 2" STAINLESS STEEL GRATE STAINLESS SHEET METAL TRENCH DRAIN PAN W/ +2" OVERFLOW DAM 4" PVC OR ABS ROOF DRAIN PIPE INSTALL W/ DIRECTIONAL DWV FITTINGS. OVERFLOW @ +2" HIGH AND DRAINED SEPARATELY. 10 1/4" 4X FRMG JOISTS (PER STRUCTURAL DRAWINGS) DROP SOFFIT WITH CLASS 'A' 1-HR CONSTRUCTION SLOPE TO DRAIN SLOPE TO DRAIN SLOPE TO DRAIN TO WALL DRAIN SEE 2ND FLR FLAN A2.2 (OR EQUAL) AND 1/2" EXTERIOR GRADE PLYWOOD TWO LAYERS GRADE 'D' BUILDING PAPER 7/8" EXTERIOR PLASTER OVER METAL LATH, 2" MI N . 6" 8" MI N . FINISH GRADE PLASTER FINISH COAT OVER FACE OF CONCRETE SLAB/FOOTING 2x6 P.T.D.F. SILL PLATE PROVIDE PLYWOOD SHEAHTHING BEHIND SCREED AT AREAS WITHOUT SHEAR PANELS TO MATCH THICKNESS OF SHEAR PANELS, TYP. CONT. 12" STRIP OF SELF ADHERED MEMBRANE - LAP OVER SCREED FLANGE (PROVIDE BLOCKING AS REQUIRED FOR SOLID BACKING) CORROSION RESISTANT WEEP SCREED LAP GRADE 'D' PAPER OVER SCREED FLANGE (OR EQUAL) AND 1/2" EXTERIOR GRADE PLYWOOD TWO LAYERS GRADE 'D' BUILDING PAPER 7/8" EXTERIOR PLASTER OVER METAL LATH, 5/8" TYPE 'X' GYPSUM BOARD 2X6 EXTERIOR STUD WALL FRAMING CONCRETE FOUNDATION VA R I E S CURB WIDTH PER STRUCTURAL DRAWINGS (PER STRUCTURAL DRAWINGS) WEEP SCREED @ CURB WOOD BLOCKING PER STRUCTURAL GRK, SS 5/16" FASTENER 3/4" SIDING OR 7/8" STUCCO 5" X 5" BASE PLATE 5/8" 3/4"3/4"3 3/4" DEX-O-TEC TRIM RING 5/8" 5" STAINLESS STEEL DRIP EDGE SST STANCHION RAILING POST 3/4" PLYWOOD 7/8" EXTERIOR PLASTER OVER METAL LATH, TWO LAYERS GRADE 'D' BUILDING PAPER (OR EQUAL) AND 1/2" EXTERIOR GRADE PLYWOOD CONT. 12" STRIP OF SELF-ADHERED MEMBRANE -LAP OVER GRADE 'D' BUILDING PAPER 4X FRMG (RIPPED TO SLOPE). (PER STRUCTURAL DRAWINGS) SLOPE TO DRAIN BOX PER PLAN AND 11/AD2 10SCALE: 3" = 1'-0"CABLE RAIL MOUNTING DETAIL CORROSION-RESISTANT METAL GUTTER CORROSION RESISTANT METAL EDGE FLASHING PLOT DATE: SCALE: DESIGN BY: DRAWN BY: CHECKED DATE: FILE NAME: SH E E T S : REVISIONS: BILL DURANT Th e 9 4 4 V i a L i d o N o r d T r u s t 94 4 V i a L i d o N o r d Ne w p o r t B e a c h , C A 9 2 6 6 3 P 562.424.8816 F 562.424.8440 STAMP: BI L L D U R A N T De s i g n e r / B u i l d e r 22 5 9 O r a n g e A v e n u e Si g n a l H i l l , C a l i f o r n i a 9 0 7 5 5 AS NOTED Z: \ P r o j e c t F o l d e r s \ P r o j e c t s - 2 0 1 8 \ 9 4 4 V i a L i d o N o r d T r u s t \ 3 - P l o t S h e e t s \ D e t a i l s . d w g Details BI L L D U R A N T De s i g n e r / B u i l d e r 22 5 9 O r a n g e A v e n u e Si g n a l H i l l , C a l i f o r n i a 9 0 7 5 5 July 24, 2020 RM / KC AS NOTED Z: \ P r o j e c t F o l d e r s \ P r o j e c t s - 2 0 1 8 \ 9 4 4 V i a L i d o N o r d T r u s t \ 3 - P l o t S h e e t s \ D e t a i l s . d w g Details DETAILS AD.2 TYPICAL/MISC. SELF-SEALING, TEAR-RESISTANT WATERPROOF MEMBRANE - WEATHERLAP AS INDICATED, TYP. WINDOW, DOOR OR OTHER FRAMED PENETRATION REFER TO EXTERIOR ELEVATIONS AND DETAILS SEAL BETWEEN FRAME/FLANGE AND 'SISAL KRAFT' PAPER (OR APPROVED ALTERNATE), WITH BITUTHENE SEALANT, TYPICAL ALL AROUND LAP 2" MINIMUM AT HORIZONTAL JOINTS, AND 6" MINIMUM AT VERTICAL JOINTS. "60 MINUTE" GRADE 'D' WATER-RESISTANT TO EXTERIOR, TYPICAL NOTE: USE TWO LAYERS AT PLASTER OVER PLYWOOD AREAS TYPICAL BUILDING PAPER WEATHERLAP TO SHED WATER TRIM, OR OTHER FINISH - PROVIDE WEATHER SEE EXTERIOR ELEVATIONS FOR STUCCO, WOOD "THIS DETAIL APPLIES TO ALL PENETRATIONS" NOTES: PROTECTION, INCLUDING FLASHING AND COUNTERFLASHING PER CURRENT C.B.C. C B A A B C D 12" WIDE MIN. FLEXIBLE, HIGH-STRENGTH, 12" MIN. TYP. LA P 4 " MI N . , T Y P . LAP 4" MIN., TYP. * 1SCALE: 3" = 1'-0" SCALE: 3" = 1'-0" SCALE: 3" = 1'-0" SCALE: 3" = 1'-0" PENETRATION FLASHING SCALE: 3" = 1'-0" SCALE: 3" = 1'-0" SCALE: 3" = 1'-0" -- SCALE: 3" = 1'-0" SCALE: 3" = 1'-0" 2 3 7 8 912 11 10 - WINDOW HEAD WINDOW JAMB WINDOW SILL FACE OF WALL BATT INSULATION (PER TITLE 24 REPORT) BATT INSULATION (PER TITLE 24 REPORT) BATT INSULATION (PER TITLE 24 REPORT) 7/8" EXTERIOR PLASTER OVER METAL LATH, TWO LAYERS GRADE 'D' BUILDING PAPER 5/8" TYPE 'X' GYPSUM BOARD 2X4 EXTERIOR STUD WALL FRAMING LINE OF JAMB BEYOND ONE LAYER OF SELF ADHERED MEMBRANE OVER WINDOW FLANGE AND 6" UP FACE OF WALL HEADER - REFER TO STRUCTURAL DRAWINGS PLYWOOD WALL SHEATHING, WHERE OCCURS (REFER TO STRUCTURAL DRAWINGS) 7/8" EXTERIOR PLASTER OVER METAL LATH, TWO LAYERS GRADE 'D' BUILDING PAPER 5/8" TYPE 'X' GYPSUM BOARD 2X4 EXTERIOR STUD WALL FRAMING PLYWOOD WALL SHEATHING, WHERE OCCURS (REFER TO STRUCTURAL DRAWINGS) ONE LAYER OF SELF ADHERED MEMBRANE BEHIND WINDOW FLANGE AND 6" OUT LAP (1) LAYER OF GRADE 'D' BUILDING PAPER UNDER SELF ADHERED MEMBRANE LAP (1) LAYER OF GRADE 'D' BUILDING PAPER UNDER GRADE 'D' PAPER BIB ONE LAYER OF 40 mil SELF ADHERED MEMBRANE BEHIND WINDOW FLANGE AND INTO ROUGH OPENING, AND 6" DOWN FACE OF WALL 7/8" EXTERIOR PLASTER OVER METAL LATH, TWO LAYERS GRADE 'D' BUILDING PAPER 2X4 EXTERIOR STUD WALL FRAMING 5/8" TYPE 'X' GYPSUM BOARD PLYWOOD WALL SHEATHING, WHERE OCCURS (REFER TO STRUCTURAL DRAWINGS) LINE OF JAMB BEYOND VINYL WINDOW SYSTEM VINYL WINDOW SYSTEM VINYL WINDOW SYSTEM BATT INSULATION (PER TITLE 24 REPORT) 7/8" EXTERIOR PLASTER OVER METAL LATH, TWO LAYERS GRADE 'D' BUILDING PAPER (OR EQUAL) AND 1/2" EXTERIOR GRADE PLYWOOD 5/8" TYPE 'X' GYPSUM BOARD 2X6 EXTERIOR STUD WALL FRAMING PLYWOOD WALL SHEATHING, WHERE OCCURS (REFER TO STRUCTURAL DRAWINGS) PROVIDE METAL CASING AT KERF TO TERMINATE GYPSUM BOARD ONE LAYER OF SELF ADHERED MEMBRANE- LAP BEHIND FLASHING FLANGE, INTO ROUGH OPENING AND 6" OUT FACE OF WALL LAP TWO LAYERS GRADE 'D' BUILDING PAPER OVER FLASHING FLANGE WOOD DOOR FRAME LINE OF BASE BELOW CORROSION RESISTANT METAL FLASHING SET INTO KERF AT DOOR JAMB DOOR (REFER TO EXTERIOR ELEVATIONS) BATT INSULATION (PER TITLE 24 REPORT) CORROSION RESISTANT METAL FLASHING 7/8" EXTERIOR PLASTER OVER METAL LATH, TWO LAYERS GRADE 'D' BUILDING PAPER 5/8" TYPE 'X' GYPSUM BOARD 2X6 EXTERIOR STUD WALL FRAMING LINE OF JAMB BEYOND ONE LAYER OF SELF ADHERED MEMBRANE OVER FLASHING FLANGE AND 6" UP FACE OF WALL HEADER - REFER TO STRUCTURAL DRAWINGS PLYWOOD WALL SHEATHING, WHERE OCCURS (REFER TO STRUCTURAL DRAWINGS) LAP GRADE 'D' BUILDING PAPER OVER FLASHING FLANGE LAP TWO LAYERS GRADE 'D' BUILDING PAPER OVER FLASHING FLANGE WOOD DOOR FRAME PROVIDE METAL CASING TO TERMINATE GYPSUM BOARD CORROSION RESISTANT METAL FLASHING WITH DRIP EDGE DOOR (REFER TO EXTERIOR ELEVATIONS) NOTE: REFER TO DETAIL 1/AD.1 FOR FLASHING AND BLD.'G PAPER INSTALLATION REQUIREMENTS. NOTE: REFER TO DETAIL 2/AD.1 FOR FLASHING AND BLD.'G PAPER INSTALLATION REQUIREMENTS. SCALE: 3" = 1'-0"6 DOOR HEAD 4SCALE: 3" = 1'-0" DOOR JAMB SCALE: 3" = 1'-0"5 FINISH FLOORING 40 mil SELF ADHERED MEMBRANE OVER WOOD SPACER AND 2" MIN. DOWN FACE OF SLAB DOOR (REFER TO EXTERIOR ELEVATIONS) ALUMINUM THERMAL BARRIER THRESHOLD WITH SLIP RESISTANT SURFACE - SET THRESHOLD IN APPROVED MASTIC - (MECHANICALLY FASTEN) 12" M I N . 4" M A X . DOOR THRESHOLD @ BALCONY NOT USED DECK FRAMING (PER STRUCTURAL DRAWINGS) FLOOR FRAMING (PER STRUCTURAL DRAWINGS) REFER TO STRUCTURAL DETAILS PLOT DATE: SCALE: DESIGN BY: DRAWN BY: CHECKED DATE: FILE NAME: SH E E T S : REVISIONS: BILL DURANT Th e 9 4 4 V i a L i d o N o r d T r u s t 94 4 V i a L i d o N o r d Ne w p o r t B e a c h , C A 9 2 6 6 3 P 562.424.8816 F 562.424.8440 STAMP: BI L L D U R A N T De s i g n e r / B u i l d e r 22 5 9 O r a n g e A v e n u e Si g n a l H i l l , C a l i f o r n i a 9 0 7 5 5 AS NOTED Z: \ P r o j e c t F o l d e r s \ P r o j e c t s - 2 0 1 8 \ 9 4 4 V i a L i d o N o r d T r u s t \ 3 - P l o t S h e e t s \ D e t a i l s . d w g Details BI L L D U R A N T De s i g n e r / B u i l d e r 22 5 9 O r a n g e A v e n u e Si g n a l H i l l , C a l i f o r n i a 9 0 7 5 5 July 24, 2020 RM / KC AS NOTED Z: \ P r o j e c t F o l d e r s \ P r o j e c t s - 2 0 1 8 \ 9 4 4 V i a L i d o N o r d T r u s t \ 3 - P l o t S h e e t s \ D e t a i l s . d w g Details DETAILS AD.3 DOOR AND WINDOW STRONG-WALL® WOOD SHEARWALL TOP PLATES RIM JOIST, BEAM, OR BLOCKING IF APPLICABLE HEX NUT AND STRUCTURAL WASHER WSW HOLDOWN SEE 10/WSW2 FOR ALLOWABLE EDGE AND FACE DRILL ZONES WSW DESIGNED TO PROVIDE 18" GAP BETWEEN LSL AT BASE OF WSW AND CONCRETE. ENSURE CONCRETE IS LEVEL AND SMOOTH BENEATH PANEL. GRIND OR FILL AS NECESSARY. REGISTERED DESIGN PROFESSIONAL IS PERMITTED TO MODIFY DETAILS FOR SPECIFIC CONDITIONS. OR6 7 OR4 5 ALTERNATE 78" MAXIMUM WOOD SHIM. FOR SHIMS GREATER THAN 78", SEE 9/WSW2. WSW-TOW SHEAR TRANSFER PLATE ALTERNATE WSW GARAGE FRONT OPTIONS FR A M I N G D E T A I L S EN G I N E E R E D D E S I G N S 0 07 / 0 1 / 2 0 1 6 MODEL NO.W (in.) H (in.) ANCHOR BOLTS TOTAL WALL WEIGHT (lb.)QUANTITY DIA. (in.) WSW12x7 12 78 2 7/8 100 WSW18x7 18 78 27/8 145 WSW12x7.5 12 85 1/2 2 7/8 110 WSW18x7.5 18 85 1/2 2 7/8 155 WSW12x8 12 93 1/4 2 7/8 115 WSW18x8 18 93 1/4 2 7/8 165 WSW24x8 24 93 1/4 2 1 225 WSW12x9 12 105 1/4 2 7/8 130 WSW18x9 18 105 1/4 2 7/8 185 WSW24x9 24 105 1/4 2 1 245 WSW12x10 12 117 1/4 2 7/8 140 WSW18x10 18 117 1/4 2 7/8 205 WSW24x10 24 117 1/4 2 1 270 WSW12x11 12 129 1/4 2 7/8 150 WSW18x11 18 129 1/4 2 7/8 220 WSW24x11 24 129 1/4 2 1 295 WSW12x12 12 141 1/4 2 7/8 165 WSW18x12 18 141 1/4 2 7/8 240 WSW24x12 24 141 1/4 2 1 320 WSW18x13 18 153 1/4 2 7/8 255 WSW24x13 24 153 1/4 21 345 WSW24x14 24 168 21 375 WSW24x16 24 192 2 1 425 WSW18x20 18 240 27/8 385 WSW24x20 24 240 2 1 520 NOTES: 1. FOR HEIGHTS NOT LISTED, ORDER THE NEXT TALLEST PANEL AND TRIM TO FIT. MINIMUM TRIMMED HEIGHT FOR ALL PANELS IS 74½". 2. ALL PANELS COME WITH TWO PRE-ATTACHED HOLDOWNS, TWO STANDARD HEX NUTS, TWO STRUCTURAL WASHERS, TWO WSW-TOW PLATES AND INSTALLATION INSTRUCTIONS. 3.ALL PANELS ARE 3½" THICK. STRONG-WALL®WOOD SHEARWALL MODELS SEE SHEETS WSW1 AND WSW1.1 FOR ANCHORAGE SOLUTIONS HEX NUT AND STRUCTURAL WASHER PLACE STRONG-WALL® WOOD SHEARWALL OVER THE ANCHOR BOLTS AND SECURE WITH WASHER AND HEX NUTS (PROVIDED). SNUG TIGHT FIT REQUIRED; DO NOT USE AN IMPACT WRENCH. x USE 1516" WRENCH FOR 78" NUT x USE 112" WRENCH FOR 1" NUT SEE SHEETS WSW1 AND WSW1.1 FOR ANCHORAGE SOLUTIONS STRONG-WALL® WOOD SHEARWALL STRONG-WALL® WOOD SHEARWALL STRONG-WALL® WOOD SHEARWALL JOIST HANGER (IF REQUIRED) FRAMING BY OTHERS (TYPICAL) SILL PLATE ANCHORAGE BY OTHERS STRONG-WALL®WOOD SHEARWALL HEIGHT TO INCLUDE THE DEPTH OF THE FLOOR SYSTEM AND SHALL BE INSTALLED DIRECTLY ON THE FOUNDATION. SPECIFY PANEL HEIGHT FROM TOP OF FOUNDATION TO UNDERSIDE OF TOP PLATES OR BEAM. TOP PLATES 78" MAXIMUM WOOD SHIM. FOR SHIMS GREATER THAN 78", SEE 9/WSW2. ATTACH WSW-TOW PLATES (PROVIDED) TO FRAMING AND WSW PANEL BOTH SIDES USING 10d x 212" NAILS MIN. FOR ALTERNATE CONNECTION SEE 7/WSW2. 4 OR6 7 ALTERNATE 4 REGISTERED DESIGN PROFESSIONAL IS PERMITTED TO MODIFY DETAILS FOR SPECIFIC CONDITIONS. ROUGH OPENING HEIGHT H CURB SHEAR TRANSFER DESIGN AND DETAILS BY OTHERS POST AND CONNECTION DETAILS BY OTHERS 318" MIN. WIDTH BY 9 14" MIN. DEPTH HEADER BY OTHERS. FOR WSW AND HEADER FURRING REQUIREMENTS, WHEN APPLICABLE, SEE DETAILS 4/WSW4 AND 5/WSW4. GARAGE HEADER ROUGH OPENING HEIGHT MODEL NO. H CURB ROUGH OPENING HEIGHT WSW12x7 WSW18x7 WSW24x7 512"6'-1112" 6"7'-0" WSW12x7.5 WSW18x7.5 WSW24x7.5 0"7'-112" WSW12x8 WSW18x8 WSW24x8 512"8'-234" 6"8'-314" NOTES: 1. IF REQUIRED ROUGH OPENING HEIGHT EXCEEDS TABLE VALUE, SPECIFY NEXT TALLER PANEL AND TRIM AS NECESSARY. THE STRONG-WALL® WOOD SHEARWALL MAY BE TRIMMED TO A MINIMUM HEIGHT OF 7412". 2. FURRING DOWN GARAGE HEADER MAY BE REQUIRED FOR CORRECT ROUGH OPENING HEIGHT. GARAGE WALL OPTION 1 GARAGE WALL OPTION 2 FOR GARAGE WALL OPTION 2, REGISTERED DESIGN PROFESSIONAL SHALL DESIGN AND DETAIL FOR : 1. SHEAR TRANSFER 2. OUT-OF-PLANE LOADING EFFECT 3. INCREASED OVERTURNING AND DRIFT DUE TO ADDITIONAL HEIGHT ALIGN WSW-TOW NOTCHES WITH BOTTOM OF TOP PLATES SECTION4x FRAMING FOR 518"–512" FRAMING, ATTACH DFL, SP OR SCL WOOD FURRING BLOCK BETWEEN WSW PANEL AND WSW-TOW WITH SDS 14" x 312" SCREWS (MIN.) OR 16d COMMON NAILS (8 TOTAL FASTENERS FOR WSW12, 10 FOR WSW18 AND 14 FOR WSW24). MINIMUM BLOCK SIZE IS 134" x 1178" x WSW PANEL WIDTH. 2" MIN. 3" MIN. 3" MIN. 2" MIN. DFL, SP OR SCL WOOD FURRING BLOCK (REQUIRED FOR 518"–512" FRAMING MEMBERS) TOP PLATES 78" MAXIMUM WOOD SHIM. FOR SHIMS GREATER THAN 78", SEE 9/WSW2. ATTACH WSW-TOW PLATE (PROVIDED) ON ONE SIDE ONLY WITH A COMBINATION OF SDS 14" x 6" AND SD #10 x 112" CONNECTOR SCREWS (ORDER SEPARATELY AS WSW-TOW__KT) ALIGN WSW-TOW NOTCHES WITH BOTTOM OF TOP PLATES SIMPSON STRONG-TIE® A35 FRAMING ANCHORS DOUBLE TOP PLATES OPTIONAL 1" DIAMETER BY 14" DEEP COUNTERBORE WSW-TOW ALTERNATE CONNECTION KIT MODEL NO.FASTENER QUANTITY SD #10 x 112"SDS14" x 6" WSW-TOW12KT 20 2 WSW-TOW18KT 28 4 WSW-TOW24KT 40 8 FURRING NOT REQUIRED FOR ALTERNATE TOP CONNECTION EXCEPT AS REQUIRED FOR FINISH MATERIAL ATTACHMENT B W L L= W(MIN.) NOTES: 1. MAINTAIN END DISTANCES TO PREVENT SCREWS FROM PENETRATING THROUGH THE OUTER EDGES. 2. INSTALL SCREWS PERPENDICULAR TO THE TOP PLATE. 3. EDGE DISTANCES ASSUME DOUBLE TOP PLATE. SECTION VIEW2X6 OR WIDER FRAMING A INSTALLATION NOTES : 1. ACTUAL CUT LENGTH (L) MUST BE GREATER THAN OR EQUAL TO PANEL WIDTH (W). 2. THIS DETAIL APPLICABLE FOR SLOPES UP TO 12:12. 3. PANELS TALLER THAN 12' MUST BE DESIGNED FOR THE APPLICATION. EDGE DISTANCE FOR SCREWS SLOPE A (in.) B (in.) 0:12-4:12 2 3 5:12-8:12 1 1/2 4 1/2 9:12-12:12 1/2 5 1/2 (4) SIMPSON STRONG-TIE® LTP4 OR A35 FRAMING ANGLES. MAY BE USED IN COMBINATION (2 PER SIDE). NO HOLES IN HATCHED REGION. END OF PANEL TO NEAREST SCREW (SEE TABLE) INSTALL SDS 14" x 6" SCREWS (ORDER SEPARATELY). INSTALL IN 2 ROWS AS SHOWN AND COUNTERSINK AS REQUIRED. SIMPSON STRONG-TIE® LTP4 FRAMING ANCHORS STRONG-WALL® WOOD SHEARWALL PLAN VIEW SDS SCREW SPACING 138" O.C. MIN.12" MIN. SDS TIP TO CHASE QTY. OF SDS14" x 6" SCREWS REQ'D. WSW12 4 WSW18 8 WSW24 12 12" MIN. AT EDGE 1" MIN. FROM EDGE W 114" MIN. ROW SPACING SECTION FOR 8" TO 12" BLOCK DEPTHS: ATTACH SIMPSON STRONG-TIE® CS16 STRAPS AT EDGE OF WSW PANEL (EACH SIDE) USING 10d x 1½" NAILS SHIM BLOCK HEIGHTS GREATER THAN 8" AND UP TO 10": x 8 NAILS INTO BLOCKx8 NAILS INTO WSW PANEL SHIM BLOCK HEIGHTS GREATER THAN 10" AND UP TO 12":x 10 NAILS INTO BLOCKx10 NAILS INTO WSW PANEL REGISTERED DESIGN PROFESSIONAL SHALL DESIGN AND DETAIL FOR : 1. SHEAR TRANSFER 2. OUT-OF-PLANE LOADING EFFECT 3. INCREASED OVERTURNING AND DRIFT DUE TO ADDITIONAL HEIGHT 418" TO 12" SHIM BLOCK 1" TO 4" SHIM BLOCK CRIPPLE WALL INSTALL SDS 14" x 6" SCREWS (MIN.) FROM THE TOP SIDE OF THE PLATES PER QTY. AND SPACING REQUIREMENTS DETAILED IN 8/WSW2. STRONG-WALL® WOOD SHEARWALL FULL-HEIGHT ADJACENT FRAMING BY OTHERS LTP4 SPACING BY OTHERS 4x SHIM BLOCK FULL-HEIGHT ADJACENT FRAMING BY OTHERS SEE 6 & 7/WSW2 FOR TOP CONNECTION CRIPPLE SHEARWALL, BLOCKING AND STRAP BY OTHERS NO HOLES ALLOWED IN TOP 8" OF PANEL FACE DRILL ZONE CENTER 458" OF PANEL FACE AS SHOWN ALTERNATE FRAMING BY OTHERS (NOT SHOWN FOR CLARITY) 1. STRONG-WALL WOOD SHEARWALL IS MANUFACTURED AND TRADEMARKED BY "SIMPSON STRONG-TIE COMPANY INC."HOME OFFICE: 5956 W. LAS POSITAS BLVD. , PLEASANTON, CA 94588 TEL: (800) 999-5099, FAX: (925) 847-1597. "SIMPSON STRONG-TIE COMPANY INC." IS AN ISO 9001-2008 REGISTERED COMPANY. 2. USE OF THIS PRODUCT IS SUBJECT TO THE APPROVAL OF THE LOCAL BUILDING DEPARTMENT. 3. THIS PRODUCT IS PART OF THE OVERALL LATERAL FORCE RESISTING SYSTEM OF THE STRUCTURE. DESIGN OF THE BUILDING'S LATERAL FORCE RESISTING SYSTEM, INCLUDING THE LOAD PATH TO TRANSFER LATERAL FORCES FROM THE STRUCTURE TO THE GROUND, IS THE RESPONSIBILITY OF THE DESIGNER. 4. ENGINEER OF RECORD IS PERMITTED TO MODIFY DETAILS FOR SPECIFIC CONDITIONS. 5. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, CONDITIONS, ELEVATIONS, ETC. PRIOR TO INSTALLATION OF ANY COMPONENTS FOR THE STRONG-WALL SB SYSTEM. IF ANY DISCREPANCIES ARE FOUND, THEY SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGNER FOR CLARIFICATION PRIOR TO CONSTRUCTION. 6. INSTALLATION OF PRODUCT SHALL BE DONE IN CONFORMANCE TO THESE DRAWINGS. THE PERFORMANCE OF MODIFIED PRODUCTS OR ALTERED INSTALLATION PROCEDURES ARE THE SOLE RESPONSIBILITY OF THE DESIGNER. 7. SIMPSON STRONG-TIE COMPANY INC. RESERVES THE RIGHT TO CHANGE SPECIFICATIONS, DESIGNS, AND MODELS WITHOUT NOTICE OR LIABILITY FOR SUCH CHANGES. 8. ALL HARDWARE CALLED OUT IS SIMPSON STRONG-TIE. 9. SEE ICC-ES ESR-2652 OR CITY OF LOS ANGELES RR25730 AS APPLICABLE FOR ADDITIONAL INFORMATION. 6 1" DIAMETER BY 14" DEEP COUNTERBORE STRONG-WALL® WOOD SHEARWALL SECTION6x FRAMING INSTALL SDS 14" x 6" SCREWS AT AN ANGLE THAT PREVENTS THEM FROM EXITING SIDE OF FRAMING; APPROX. 30 DEGREES (TYP.) INSTALL WSW-TOW ON EXTERIOR FACE REGISTERED DESIGN PROFESSIONAL IS PERMITTED TO MODIFY DETAILS FOR SPECIFIC CONDITIONS. ALLOWABLE SMALL HOLESFACE AND EDGE DRILL ZONES ALLOWABLE LARGE HOLESIN ADDITION TO ALLOWABLESMALL HOLES STRONG-WALL® WOOD SHEARWALL STRONG-WALL® WOOD SHEARWALL SDS14" x 312" SD #10 x 112" 4x SHIM BLOCK STRONG-WALL® WOOD SHEARWALL SEE 6 & 7/WSW2 FOR TOP CONNECTION OR6 7 WHEN WSW-PS STRAPS OMITTED, ALLOWABLE SHEAR VALUES FOR STANDARD PANEL APPLY. NAILING BY OTHERS FRAMING BY OTHERS 94 75 1 2 3 8 STANDARD INSTALLATION BASE CONNECTION STANDARD TOP CONNECTION TOP OF WALL HEIGHT ADJUSTMENTS TRIM ZONE AND ALLOWABLE HOLESALTERNATE TOP CONNECTIONWOOD FLOOR SYSTEM BASE CONNECTIONSINGLE STORY WSW ON CONCRETE RAKE WALL NOTES STRONG-WALL® WSW MODELS 10 11 HOLES FOR WSW24X7 PANEL ONLY x MAX. OF ONE 458" x 6" HOLEx8" FROM TOP OF PANEL, MIN. NO EDGE HOLES ALLOWED IN LOWER 26" OF PANEL NO FACE HOLES ALLOWED IN LOWER 40" OF PANEL HOLES x MAX. THREE HOLES IN FACE AND THREE IN EDGE. x 34"-DIAMETER HOLES, MAX.x 6" O.C., MIN. FACE DRILL ZONE MAINTAIN 112" MIN. EDGE DISTANCE FROM CHASE AND OUTSIDE EDGE, TYPICAL. NO HOLES ALLOWED IN TOP 8" OF PANEL EDGE DRILL ZONE MIDDLE 13 OF PANEL THICKNESS 2418" 16" 12" ABOVE EXISTING HOLE, MIN. ® ® ® ® 4" MIN. CLEARANCE REGISTERED DESIGN PROFESSIONAL IS PERMITTED TO MODIFY DETAILS FOR SPECIFIC CONDITIONS. REGISTERED DESIGN PROFESSIONAL IS PERMITTED TO MODIFY DETAILS FOR SPECIFIC CONDITIONS. PLACE STRONG-WALL® WOOD SHEARWALL OVER THE ANCHOR BOLTS AND SECURE WITH WASHER AND HEX NUTS (PROVIDED). SNUG TIGHT FIT REQUIRED; DO NOT USE AN IMPACT WRENCH. x USE 1516" WRENCH FOR 78" NUTxUSE 112" WRENCH FOR 1" NUT REGISTERED DESIGN PROFESSIONAL IS PERMITTED TO MODIFY DETAILS FOR SPECIFIC CONDITIONS. REGISTERED DESIGN PROFESSIONAL IS PERMITTED TO MODIFY DETAILS FOR SPECIFIC CONDITIONS. STRONG-WALL® WOOD SHEARWALL SECTION 4x FRAMING SECTION 6x FRAMING REGISTERED DESIGN PROFESSIONAL IS PERMITTED TO MODIFY DETAILS FOR SPECIFIC CONDITIONS. HOLES x 458"-DIA. HOLES, MAX. x MAX. OF TWO 458"-DIA. HOLES OR ONE 414" x 12" HOLE.x NO MINIMUM ON-CENTER SPACING REQUIRED. DEC 16, 2022