Loading...
HomeMy WebLinkAboutPA2023-0087_20230719_Architectural Plans_36x24T-01 COVER SHEET Revisions Drawing Title Date: 07/18/2023 Aqx Job No: 2022-628 Drawing No. Drawn: A.B. PROJECT 216 E Balboa Blvd, Newport Beach, CA 92661 DUPLEX & TWO ADU's STUDIO ARCHITECTURAL VICINITY MAP GENERAL NOTES BMP. NOTES BUILDING DATA PROJECT DESCRIPTION (SCOPE OF WORK): BUILDING CODE: STRUCTURAL: ARCHITECTURAL: TEAM MEMBERS DUPLEX & TWO ADU's SHEET INDEX ARCHITECTURAL BUILDING AND OTHER AREA: ’ NPDES NOTES USE OCCUPANCY AND FLOOR AREA: PROJECT LOCATION GRADE ESTABLISHMENT: DEFERRED SUBMITTAL: “” NOTES T-02 GENERAL NOTES Revisions Drawing Title Date: 07/18/2023 Aqx Job No: 2022-628 Drawing No. Drawn: A.B. PROJECT 216 E Balboa Blvd, Newport Beach, CA 92661 DUPLEX & TWO ADU's STUDIO ARCHITECTURAL T-03 GENERAL NOTES Revisions Drawing Title Date: 07/18/2023 Aqx Job No: 2022-628 Drawing No. Drawn: A.B. PROJECT 216 E Balboa Blvd, Newport Beach, CA 92661 DUPLEX & TWO ADU's STUDIO ARCHITECTURAL T-04 GENERAL NOTES Revisions Drawing Title Date: 07/18/2023 Aqx Job No: 2022-628 Drawing No. Drawn: A.B. PROJECT 216 E Balboa Blvd, Newport Beach, CA 92661 DUPLEX & TWO ADU's STUDIO ARCHITECTURAL S 17°21'14" W 79.80' N 7 1 ° 4 2 ' 1 5 " W 30 . 0 0 ' N 7 1 ° 3 9 ' 1 1 " W 30 . 0 1 ' S 17°21'02" W 79.82' 50' 7.5'7.5' 19'-2"5'-0"50'-7"5'-0" 24 ' - 0 " 3'- 0 " 3'- 0 " 24 ' - 0 " 3'- 0 " 3'- 0 " 24 ' - 0 " 3'- 0 " 3'- 0 " GRADE ESTABLISHMENT A-01 GRADE ESTABLISHMENT CALCULATION Revisions Drawing Title Date: 07/18/2023 Aqx Job No: 2022-628 Drawing No. Drawn: A.B. PROJECT 216 E Balboa Blvd, Newport Beach, CA 92661 DUPLEX & TWO ADU's STUDIO ARCHITECTURAL GRADE ESTABLISHMENT CAL. A A DN B B 2% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. TRENCH DRAIN TRENCH DRAIN TRENCH DRAIN CLEAN OUT SEE CITY STD-406 3'- 0 " 2'- 4 " 3'- 0 " 3'-0"2'-0"28'-9"2'-6"22'-8"5'-0" 79.82'⅊ 79.80' 30 . 0 0 ' 30 . 0 1 ' ⅊ ⅊ ⅊ 3'- 8 " 3'- 0 " 11 ' - 3 " 3'- 0 " 9'- 1 " 15'-11" 15 ' - 1 0 " 3: 1 2 5' - 1 0 " 23'-10" 20'-9" 36'-0" 3: 1 2 3: 1 2 3: 1 2 EL 31.56 TOP OF GUARDRAIL EL 31.56 TOP OF GUARDRAIL 38.12 RIDGE HEIGHT MAX. BUILDING HEIGHT 38.12 RIDGE HEIGHT MAX. BUILDING HEIGHT EL 31.56 TOP OF GUARDRAIL 28.06 F.F. THIRD FLOOR (DECK) 28.40 F.F. MAX. HEIGHT ROOF TOP (ADU) 19.23 F.F. (ADU) SECOND FLOOR EL 22.73 TOP OF GUARDRAIL ·A CERTIFIED BUILDING HEIGHT CERTIFICATION MUST BE SUBMITTED AFTER FRAMING AND INSTALLATION OF THE ROOF MATERIAL. MEASURE FROM AVERAGE CURB AS DETERMINED BY TOPOGRAPHIC SURVEY. ·THE MAXIMUM TIME TO COMPLETE CONSTRUCTION ON A PROJECT IS LIMITED TO THREE YEARS FROM THE DATE OF THE PERMIT FOR ALL PERMITS ISSUED AFTER JUNE 01, 2019 AS REQUIRED BY NBMC SECTION 15.02.095. ·PROVIDE A PROJECT INFORMATION SIGN FOR PROJECTS REQUIRING FENCING (NEW STRUCTURE OR ADDITION AND REMODEL TO AN EXISTING STRUCTURE WITH A COMBINED FLOOR AREA EXCEEDING SEVENTY-FIVE (75) PERCENT OF THE FLOOR AREA OF THE PROPOSED STRUCTURE) IN DESIGNATED “HIGH DENSITY AREAS”. PROJECT SIGN SHALL COMPLY WITH NBMC SECTION 15.60.030. NOTES A-02 SITE PLAN Revisions Drawing Title Date: 07/18/2023 Aqx Job No: 2022-628 Drawing No. Drawn: A.B. PROJECT 216 E Balboa Blvd, Newport Beach, CA 92661 DUPLEX & TWO ADU's STUDIO ARCHITECTURAL SITE PLAN A A UP 19'-6" 3'- 0 " 3'- 0 " 19'-0"10'-0"6"2'-6"6" 4" 19'-3" 14'-0" 5'-0"4" 12 ' - 6 " 6" 11 ' - 0 " 13'-5"2'-6" 6" 5'-0"6" 5'-0"4"6" 11 ' - 8 " 6" 7' - 6 " 4" 4"5'-0" 4" 4"10'-10" 6" 3'- 0 " 3'- 0 "STAIR 16 STEPS 6.62" RISERS 11" TREADS 2'-6" 2'-6" B B LANDING MAIN HOUSE#1 8' FLAT CEILING LIVING ROOM 8' FLAT CEILING KITCHEN 8' FLAT CEILING BEDROOM 8' FLAT CEILING BEDROOM 8' FLAT CEILING GARAGE 8' FLAT CEILING GARAGE 8' FLAT CEILING WASHER DRYER 3'- 8 " 79.82'⅊ 79.80' 30 . 0 0 ' 30 . 0 1 ' ⅊ ⅊ ⅊ 10.40 F.F. FIRST FLOOR W30W45W25 W45 D10 D 10 D25 D40 D40 D45 7'- 8 " 6" 4" 3'- 8 " 4" 3' - 6 " 4" 7' - 2 " 6" D10 D 10 4" 4"19'-0" 3'-0" 9'- 6 " 4" 9' - 6 " 6" 16 STEPS 6.62" RISERS 10" TREADS UP STAIRLANDING 6" 3'- 0 " Ø=30" W30 W35 D 45 DNUP Ø=30" Ø=30" 4"5'-0"4"4"12'-7"10'-10"6"2'-0"6"11'-8"4" 6'- 5 " 4" 3'- 6 " 6" 8'- 7 " 3'- 8 " 3'- 0 " 4" 4' - 7 " 6" 3'- 8 " 3'- 8 " 9'-0"6"4" 6" 18'-5"6"2'-6" 2'-6" 14'-2"6"13'-9"4'-0"6"2'-6" 5'-0" 3'- 0 " 6" 10 ' - 3 " 6"3'-4" 4" A A B B 1" 1" ADU #1 8' FLAT CEILING ADU #2 8' FLAT CEILING BEDROOM 8' FLAT CEILING MAIN HOUSE#2 8' FLAT CEILING LIVING ROOM 8' FLAT CEILING KITCHEN 8' FLAT CEILING MASTER BEDROOM 8' FLAT CEILING BEDROOM 8' FLAT CEILING STAIR 16 STEPS 6.62" RISERS 11" TREADS SEE SHEET AD-01 FOR GUARDRAIL DETAILS SEE SHEET AD-01 FOR GUARDRAIL DETAILS 79.82'⅊ 79.80' 30 . 0 0 ' 30 . 0 1 ' ⅊ ⅊ ⅊ W40 W05 W05 W 45 W45 W 20 W 20 W 10 D 20 D20 D 40 D40 D45 19.23 F.F. SECOND FLOOR 5'-0" 7'- 2 " 6" 3'- 0 " 6" 3'- 6 " 11 ' - 0 " 6" 4" 5'-8" 6" 3'- 0 " 6" DINING 8' FLAT CEILING 6" 12 ' - 3 " 6" 10 ' - 3 " 6" 6" 4'-0" W10 20 ' - 0 " 6" 3'- 0 " 9'-0"8'-11" 11 ' - 8 " 6" 3'- 0 " 5'-0"6"4"10'-0"4"6'-0"12'-9"6"3'-1"5'-0" 11 ' - 8 " 4" 6" 3'- 0 " 19.23 F.F. SECOND FLOOR W25W25 W45 W45 W 10 D 30 D 20 D45 D 45 D40 D40 A-03 FIRST & SECOND FLOOR PLANS FIRST FLOOR PLAN Revisions Drawing Title Date: 07/18/2023 Aqx Job No: 2022-628 Drawing No. Drawn: A.B. PROJECT 216 E Balboa Blvd, Newport Beach, CA 92661 DUPLEX & TWO ADU's STUDIO ARCHITECTURAL SECOND FLOOR PLAN DN PROVIDE GAS CONNECTION FIRE PIT AREA JACUZZI A A B B 2% MIN. 2% MIN. SEE SHEET AD-01 FOR GUARDRAIL DETAILS 2% MIN. 2% MIN. 2%MI N . 2%MI N . 2%MI N . 2%MI N . SEE SHEET AD-01 FOR GUARDRAIL DETAILS 79.82'⅊ 79.80' 30 . 0 0 ' 30 . 0 1 ' ⅊ ⅊ ⅊ SEE SHEET AD-01 FOR DRAINAGE DETAILS 2 % MI N . 2 % MI N . 2% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 5'-0"15'-10"6"3'-0"3'-0"4" 4"7'-0"6" 3'- 3 " 4" 5'- 6 " 4" 9'- 3 " 6" 2' - 0 " 3'- 0 " 6" 2' - 4 " 3'- 0 " 9'- 1 " 6" W 55 W 55 W50 MAX. CEILING HEIGHT 5'-11" DEDUCTED FROM TOTAL SQUARE FOOTAGE MAX. CEILING HEIGHT 5'-11" DEDUCTED FROM TOTAL SQUARE FOOTAGE W60 W 60 D 35 D55 D50 D55 D50 21'-0" 23'-11"36'-0" 12'-2"3'-8"1'-0"4'-0"28'-10"2'-6" 4" 10'-7"1'-5"2'-0"31'-8"2'-6" 3'- 0 " 24 ' - 0 " 3'- 0 " 5'-0" FIRST FLOOR EXTERIOR WALL FIRST FLOOR EXTERIOR WALL PONY WALL PONY WALL 28.06 F.F. THIRD FLOOR (DECK) EL 31.56 TOP OF GUARDRAIL EL 31.56 TOP OF GUARDRAIL 19.23 F.F. (ADU) SECOND FLOOR EL 22.73 TOP OF GUARDRAIL 28.40 F.F. MAX. HEIGHT ROOF TOP (ADU) EL 31.56 TOP OF GUARDRAIL 10.40 F.F. FIRST FLOOR 19.23 F.F. (ADU) SECOND FLOOR 18.40 T.PL. (GARAGE) CEILING 28.06 F.F. (ADU) 27.23 T.PL. (ADU) CEILING 28.40 (ADU) MAX. HEIGHT 10.40 F.F. FIRST FLOOR 19.39 F.F. SECOND FLOOR 18.40 T.PL. (MAIN HOUSE) CEILING 27.39 T.PL. 8' - 0 " 1' - 0 " 8' - 0 " (MAIN HOUSE) CEILING 28.39 F.F. THIRD FLOOR 1' - 0 " 9' - 9 " 9.12 GRADE ESTABLISHMENT 1' - 3 " 29 ' - 0 " 38.12 MAX. BUILDING HEIGHT 24 ' - 0 " 33.12 MAX. FLAT ROOF HEIGHT 10 " 8' - 0 " 29 ' - 0 " 24 ' - 0 " 10 " 8' - 0 " 9.12 GRADE ESTABLISHMENT 38.12 MAX. BUILDING HEIGHT 33.12 MAX. FLAT ROOF HEIGHT 3'- 6 " 3'- 6 " GARAGE CEILING AND WALL MUST BE 5/8" TYPE "X" GYP. BOARD w/1-HOUR FIRE RESISTANCE RATED UP TO CEILING INSUL. SEE T24 INSUL. SEE T24 INSUL. SEE T24INSUL. SEE T24 INSUL. SEE T24 INSUL. SEE T24 INSUL. SEE T24 SEE SHEET AD-01 FOR GUARDRAIL DETAILS PONY WALLGLASS RAILING 7'- 0 " MI N . C L R . 31.89 TOP OF GUARDRAIL 22.89 TOP OF GUARDRAIL 31.89 TOP OF GUARDRAIL 22.89 TOP OF GUARDRAIL ·THIRD FLOOR WILL NOT BE USED AS AN ADU ·THERE SHALL BE NO FACILITIES USED FOR FOOD PREPARATION WITHIN, OR BE USED FOR RESIDENTIAL PURPOSES SEPARATELY OR INDEPENDENTLY FROM OCCUPANTS OF PRINCIPLE STRUCTURE THIRD FLOOR NOTES A-04 THIRD FLOOR PLAN SECTION A-A Revisions Drawing Title Date: 07/18/2023 Aqx Job No: 2022-628 Drawing No. Drawn: A.B. PROJECT 216 E Balboa Blvd, Newport Beach, CA 92661 DUPLEX & TWO ADU's STUDIO ARCHITECTURAL THIRD FLOOR PLAN SECTION A-A 10.40 F.F. FIRST FLOOR 19.23 F.F. SECOND FLOOR 18.40 T.PL. (MAIN HOUSE) CEILING 27.23 T.PL. 8' - 0 " 10 " 8' - 0 " (MAIN HOUSE) CEILING 28.06 F.F. THIRD FLOOR 10 " 10 ' - 1 " 9.12 GRADE ESTABLISHMENT 1' - 3 " 29 ' - 0 " 38.12 MAX. BUILDING HEIGHT 24 ' - 0 " 33.12 MAX. FLAT ROOF HEIGHT 10 " 8' - 0 " 29 ' - 0 " 24 ' - 0 " 10 " 8' - 0 " 3'- 6 " 3'- 6 " SEE SHEET AD-01 FOR GUARDRAIL DETAILS SEE SHEET AD-01 FOR GUARDRAIL DETAILS 10.40 F.F. FIRST FLOOR 19.23 F.F. (ADU) SECOND FLOOR 18.40 T.PL. (GARAGE) CEILING 28.06 F.F. (ADU) 27.23 T.PL. (ADU) CEILING 28.40 (ADU) MAX. HEIGHT 9.12 GRADE ESTABLISHMENT 38.12 MAX. BUILDING HEIGHT 33.12 MAX. FLAT ROOF HEIGHT INSUL. SEE T24 INSUL. SEE T24 INSUL. SEE T24 INSUL. SEE T24 6'- 8 " MI N . C L R . PONY WALL GLASS RAILING 31.56 TOP OF GUARDRAIL 22.73 TOP OF GUARDRAIL 31.56 TOP OF GUARDRAIL 22.73 TOP OF GUARDRAIL 29 ' - 0 " 24 ' - 0 " 10.40 F.F. FIRST FLOOR 19.23 F.F. SECOND FLOOR 18.40 T.PL. (MAIN HOUSE) CEILING 27.23 T.PL. 8' - 0 " 10 " 8' - 0 " (MAIN HOUSE) CEILING 28.06 F.F. THIRD FLOOR 10 " 10 ' - 1 " 9.12 GRADE ESTABLISHMENT 1' - 3 " 29 ' - 0 " 38.12 MAX. BUILDING HEIGHT 24 ' - 0 " 33.12 MAX. FLAT ROOF HEIGHT 3'- 6 " 3'- 6 " SEE SHEET AD-01 FOR GUARDRAIL DETAILS SEE SHEET AD-01 FOR GUARDRAIL DETAILS 10.40 F.F. FIRST FLOOR 19.23 F.F. (ADU) SECOND FLOOR 18.40 T.PL. (GARAGE) CEILING 28.06 F.F. (ADU) 27.23 T.PL. (ADU) CEILING 28.40 (ADU) MAX. HEIGHT 9.12 GRADE ESTABLISHMENT 38.12 MAX. BUILDING HEIGHT 33.12 MAX. FLAT ROOF HEIGHT 7'- 0 " MI N . C L R . PONY WALLGLASS RAILING 8' - 0 " 10 " 8' - 0 " 10 " 10 ' - 1 " 1' - 3 " PR O P E R T Y L I N E PR O P E R T Y L I N E 5'-0"5'-0" 2'-6" 31.56 TOP OF GUARDRAIL 22.73 TOP OF GUARDRAIL 31.56 TOP OF GUARDRAIL 22.73 TOP OF GUARDRAIL 12 3123 12 3123 A-05 SECTION B-B EAST ELEVATION VIEW Revisions Drawing Title Date: 07/18/2023 Aqx Job No: 2022-628 Drawing No. Drawn: A.B. PROJECT 216 E Balboa Blvd, Newport Beach, CA 92661 DUPLEX & TWO ADU's STUDIO ARCHITECTURAL SECTION B-B EAST ELEVATION 29 ' - 0 " 24 ' - 0 " 10.40 F.F. FIRST FLOOR 19.23 F.F. SECOND FLOOR 18.40 T.PL. (MAIN HOUSE) CEILING 27.23 T.PL. (MAIN HOUSE) CEILING 28.06 F.F. THIRD FLOOR 9.12 GRADE ESTABLISHMENT 29 ' - 0 " 38.12 MAX. BUILDING HEIGHT 24 ' - 0 " 33.12 MAX. FLAT ROOF HEIGHT 3'- 6 " SEE SHEET AD-01 FOR GUARDRAIL DETAILS SEE SHEET AD-01 FOR GUARDRAIL DETAILS 10.40 F.F. FIRST FLOOR 19.23 F.F. (ADU) SECOND FLOOR 18.40 T.PL. (GARAGE) CEILING 28.06 F.F. (ADU) 27.23 T.PL. (ADU) CEILING 28.40 (ADU) MAX. HEIGHT 9.12 GRADE ESTABLISHMENT 38.12 MAX. BUILDING HEIGHT 33.12 MAX. FLAT ROOF HEIGHT 6'- 8 " MI N . C L R . PONY WALL GLASS RAILING 3'- 6 " 8' - 0 " 10 " 8' - 0 " 10 " 1' - 3 " 8' - 0 " 10 " 8' - 0 " 10 " 10 ' - 1 " 1' - 3 " PR O P E R T Y L I N E PR O P E R T Y L I N E 5'-0"5'-0" 2'-6" 31.56 TOP OF GUARDRAIL 22.73 TOP OF GUARDRAIL 31.56 TOP OF GUARDRAIL 22.73 TOP OF GUARDRAIL 12 3123 12 3123 29 ' - 0 " 24 ' - 0 " 10.40 F.F. FIRST FLOOR 19.23 F.F. (ADU) SECOND FLOOR 18.40 T.PL. (GARAGE) CEILING 28.06 F.F. (ADU) 27.23 T.PL. (ADU) CEILING 28.40 (ADU) MAX. HEIGHT 9.12 GRADE ESTABLISHMENT 38.12 MAX. BUILDING HEIGHT 33.12 MAX. FLAT ROOF HEIGHT PONY WALL 3'- 6 " PONY WALL 8' - 0 " 10 " 8' - 0 " 10 " 1' - 3 " PR O P E R T Y L I N E PR O P E R T Y L I N E 3'-0"3'-0" 31.56 TOP OF GUARDRAIL 22.73 TOP OF GUARDRAIL 10.40 F.F. FIRST FLOOR 19.23 F.F. SECOND FLOOR 18.40 T.PL. (MAIN HOUSE) CEILING 27.23 T.PL. 8' - 0 " 10 " 8' - 0 " (MAIN HOUSE) CEILING 28.06 F.F. THIRD FLOOR 10 " 10 ' - 1 " 9.12 GRADE ESTABLISHMENT 1' - 3 " 29 ' - 0 " 38.12 MAX. BUILDING HEIGHT 24 ' - 0 " 33.12 MAX. FLAT ROOF HEIGHT 3'- 6 " 3'- 6 " SEE SHEET AD-01 FOR GUARDRAIL DETAILS SEE SHEET AD-01 FOR GUARDRAIL DETAILS GLASS RAILING PR O P E R T Y L I N E PR O P E R T Y L I N E 3'-0"3'-0" 31.56 TOP OF GUARDRAIL 22.73 TOP OF GUARDRAIL A-06 ELEVATION VIEWS Revisions Drawing Title Date: 07/18/2023 Aqx Job No: 2022-628 Drawing No. Drawn: A.B. PROJECT 216 E Balboa Blvd, Newport Beach, CA 92661 DUPLEX & TWO ADU's STUDIO ARCHITECTURAL WEST ELEVATION NORTH ELEVATION SOUTH ELEVATION DOOR SCHEDULE NO.DESCRIPTION WIDTH HEIGHT NOTE D-20 MAIN ENTRANCE 3'-0"7'-0"CUSTOM DOOR - SHALL HAVE ONE DOOR LEAF 36" WIDE GARAGE ROLL UP 8'-0"7'-6" AUTOMATIC - CHECK MFGR'S INSTRS. FOR REQUIREMENT & DIMENSIONS - FIELD VERIFY 6'-0"6'-8" 9'-0"7'-0" 16'-0" 2'-6"D-40 EXTERIOR SLIDING 2'-10"D-45 INTERIOR SINGLE 2'-6"D-50 INTERIOR SINGLE 2'-10"INTERIOR SINGLE EXTERIOR SLIDING D-10 EXTERIOR SLIDING 7'-0" D-25 D-30 D-35 INTERIOR SINGLE 7'-0" 7'-0" D-55 6'-8" 6'-8" 4'-0"4'-0" 7'-6" 4'-0"3'-2" 6'-0" 2'-6"2'-6" 3'-0"4'-0" 7'-6"3'-8" 6'-6"4'-0" 4'-0" 4'-0" 3'-0"2'-6" 6'-8" 6'-8" 7'-0" WINDOW SCHEDULE NO.ROUGH WIDTH ROUGH HEIGHT HEAD HEIGHT NOTE 7'-0" 7'-0" 7'-0" 7'-0" 7'-0" 7'-0" W-10 W-20 W-25 W-30 W-35 W-40 W-45 W-55 W-60 2'-6"2'-6"7'-0"W-05 TEMPERED - FIX 2'-6"1'-6"6'-8"W-50 TEMPERED - FIX FIX EGRESS WINDOW EGRESS WINDOW TEMPERED - FIX CASEMENT CASEMENT CASEMENT CASEMENT CASEMENT 1.ALL NEW WINDOWS ARE DUAL GLAZED U.N.O. 2.FENESTRATION MUST HAVE TEMPORARY AND PERMANENT LABELS. 3.ALL TEMPERED GLASS TO BE ETCH MARKED. 4.ONE WINDOW IN EACH BEDROOM MUST HAVE AT LEAST 5.7 S.F. OPENABLE AREA WITH FINISHED SILL NO MORE THAN 44" ABOVE FLOOR LEVEL, MIN. OPENING HEIGHT OF 24" & MIN. OPENING WIDTH OF 20" (CLEAR). 5.ALL WINDOWS WHERE GLAZING AREA IS >9 S.F. TO BE TEMPERED 6.ALL WINDOWS WHERE GLAZING AREA'S BOTTOM EDGE IS <18" ABV. F.F. & TOP EDGE IS >36" ABV. F.F. TO BE TEMPERED. 7.WHERE A WINDOW IS LOCATED HIGHER THAN 72" ABOVE ADJACENT GRADE OR FINISHED SURFACE ON THE OPPOSITE SIDE, THE LOWER PART OF THE OPENING SHALL BE 24" MIN. ABOVE THE ROOM FINISH FLOOR SURFACE. R612.2 ALL WINDOW AND DOOR SIZES ARE NOMINAL SIZES, THEY ARE SUBJECT TO CHANGE UPON FINAL MANUFACTURER SELECTION. CONTRACTOR TO PROVIDE CUT SHEETS AND SHOP DRAWINGS TO ARCHITECT FOR APPROVAL PRIOR TO ORDERING. ·EGRESS DOOR. NOT LESS THAN ONE EGRESS DOOR SHALL BE PROVIDED FOR EACH DWELLING UNIT. THE EGRESS DOOR SHALL BE SIDE-HINGED, AND SHALL PROVIDE A CLEAR WIDTH OF NOT LESS THAN 32 INCHES (813 MM) WHERE MEASURED BETWEEN THE FACE OF THE DOOR AND THE STOP, WITH THE DOOR OPEN 90 DEGREES (1.57 RAD). ·THE CLEAR HEIGHT OF THE DOOR OPENING SHALL BE NOT LESS THAN 78 INCHES (1981 MM) IN HEIGHT MEASURED FROM THE TOP OF THE THRESHOLD TO THE BOTTOM OF THE STOP. OTHER DOORS SHALL NOT BE REQUIRED TO COMPLY WITH THESE MINIMUM DIMENSIONS. EGRESS DOORS SHALL BE READILY OPENABLE FROM INSIDE THE DWELLING WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. (R311.2) ·FLOORS AND LANDINGS AT EXTERIOR DOORS. THERE SHALL BE A LANDING OR FLOOR ON EACH SIDE OF EACH EXTERIOR DOOR. THE WIDTH OF EACH LANDING SHALL BE NOT LESS THAN THE DOOR SERVED. EVERY LANDING SHALL HAVE A DIMENSION OF NOT LESS THAN 36 INCHES (914 MM) MEASURED IN THE DIRECTION OF TRAVEL. THE SLOPE AT EXTERIOR LANDINGS SHALL NOT EXCEED 1/4 UNIT VERTICAL IN 12 UNITS HORIZONTAL (2 PERCENT). (R311.3) DOOR & WINDOW NOTES NOTES AN EMERGENCY ESCAPE AND RESCUE OPENING SHALL MEET ALL OF THE FOLLOWING (R310): ·A NET CLEAR OPENING AREA OF NOT LESS THAN 5.7 SQ. FT. (5.0 SQ. FT. FOR GRADE – FLOOR WINDOW). ·MINIMUM CLEAR OPENING HEIGHT OF 24”. ·MINIMUM CLEAR OPENING WIDTH OF 20”. ·THE BOTTOM OF WINDOW OPENING SHALL NOT BE MORE THAN 44” FROM THE FLOOR. ·SHALL OPEN DIRECTLY INTO A PUBLIC WAY, OR, TO A YARD OR COURT THAT OPENS TO A PUBLIC WAY. YARD OR COURT MUST COMPLY WITH THE DEFINITION: “AN OPEN SPACE, UNOBSTRUCTED FROM THE GROUND TO THE SKY.” THEREFORE, INGRESS/EGRESS OPENINGS WHICH OPEN UNDER OR ONTO DECKS, ROOFS, OR COVERED PATIOS ARE NOT ACCEPTABLE. R310.1 ·WINDOW CONTROL OPENING DEVICE SHALL NOT REDUCE THE REQUIRED NET CLEAR OPENING AREA OF THE WINDOW. R 312.2.2. EGRESS WINDOW A-07 DOOR & WINDOW SCHEDULES Revisions Drawing Title Date: 07/18/2023 Aqx Job No: 2022-628 Drawing No. Drawn: A.B. PROJECT 216 E Balboa Blvd, Newport Beach, CA 92661 DUPLEX & TWO ADU's STUDIO ARCHITECTURAL +15 +80 1.ALL LIGHTS SHALL BE HIGH EFFICIENCY. 2.NO VACEY SENSOR OR TIMMER IN CLOSET LESS THAN 70 SQ.FT. 3.ALL 15 & 20-AMP BRANCH CIRCUIT(S) SERVING DWELLING UNIT OUTLETS AND ALL CIRCUITS MUST BE AN ARC-FAULT CIRCUIT INTERRUPTER(S) PROTECTED. 4.VERIFY AT (E) BEDROOM RECEPTACLES ARE TO BE LOCATED IN A WALL EVERY 12 LINEAR FEET SO THAT A FIXTURE WILL NOT BE MORE THAN 6 FEET FROM ANY RECEPTACLE. 5.RECEPTACLES AT THE FRONT AND REAR OF HOME SHALL BE WITHIN 6'-6" OF GRADE. SUCH RECEPTACLES SHALL BE WATERPROOF & GFCI PROTECTED. 6.ALL EXTERIOR LIGHTING SHALL BE WATER PROOF, ALL EXTERIOR ELECTRICAL OUTLETS SHALL BE WATER PROOF AND BE GFI PROTECTED. 7.ALL OUTDOOR LIGHTING SHALL BE HIGH EFFICACY. 8.AT LEAST ONE 20 AMP BRANCH CIRCUIT SHALL BR PROVIDE TO SUPPLY BATHROOM RECEPTACLE OUTLETS. SUCH CIRCUITS SHALL HAVE ON OTHER OUTLETS. 9.GROUND FAULT CIRCUIT INTERRUPTER (GFI) RECEPTACLE PROTECTION IS REQUIRED IN THE BATH, GARAGE, OUTDOORS, UNDER FLOOR SPACE, KITCHEN COUNTERS, UNFINISHED BASEMENTS AND LAUNDRY/UTILITY/WET BAR SINKS (WHERE THE RECEPTACLE IS WITHIN 6 FT OF THE OUTSIDE SINK EDGE). 10.THE KITCHEN IS REQUIRED TO HAVE A MECHANICAL EXHAUST FAN DUCTED TO THE OUTSIDE, THE RANGE HOOD OVER THE STOVE MUST VENT TO THE OUTSIDE WITH A MINIMUM VENTILATION RATE OF 100 CFM AND USE 6"Ø DUCT MIN. THE DUCTING FOR THE EXHAUST FAN SHALL BE SIZED ACCORDING TO ASHRAE STANDARD 62.2 TABLE 7.1. 11.THE LOCAL EXHAUST FANS IN THE BATHROOMS AND KITCHENS WILL DETERMINE THE MIN. VENTILATION RATE PER ASHRAE STANDARD 62.2 EQU. 4.1(a). BATHROOM USE 4"Ø DUCT MIN. SIZE THAT ACCORDING TO ASHRAE STANDARD 62.2 TABLE 7.1 AND THIS EXHAUST FAN SHALL OPERATED CONTINUOUSLY. 12.VERIFY WITH OWNER ON ALL ELECTRICAL WIRING & SPECIFICATIONS PRIOR TO INSTALLATIONS. 13.SPEAKER/ VIDEO CABLE AND PHONE WIRING TO BE SPECIFIED BY OWNER. 14.ALL FAN SYSTEMS EXHAUSTING AIR FROM THE BUILDING ENVELOPE TO THE OUTSIDE SHALL BE PROVIDED WITH BACK-DRAFT DAMPERS. 15.ALL LIGHTING FIXTURES IN THE KITCHEN MUST BE HIGH EFFICACY CONTROLLED BY EITHER A DIMMER SWITCH OR VACANCY SENSOR THAT REQUIRES A MANUAL ON ACTIVATION. UNDER CABINETS LIGHTING REQUIRES SEPARATE SWITCH FROM OTHER LIGHTING SYSTEM. 16.ALL LIGHT FIXTURES SHALL CONTAIN BULBS THAT ARE LABELED AS JAS-2016. SCREW BASE BULBS ARE PERMITTED, EXCEPT IN RECESSED LIGHTING FIXTURES. 17.RECESSED LIGHTING SHALL BE LISTED AS IC (ZERO CLEARANCE TO INSULATION) AND AT (AIR TIGHT), BE SEALED/CAULKED BETWEEN THE FIXTURE HOUSING AND CEILING, SHALL NOT CONTAIN A SCREW BASE SOCKET, AND CONTAIN BULBS MARKED WITH JAS-20 16-E EFFICIENCY LABEL. 18.LIGHTING FIXTURES LOCATED WITHIN 3 FEET HORIZONTALLY AND S FEET VERTICALLY OF THE BATHROOM RIM OR SHOWER STALL THRESHOLD V SHALL BE LISTED FOR A DAMP LOCATION, OR LISTED FOR WET LOCATIONS WHERE SUBJECT TO SHOWER SPRAY. 19.LIGHTING IN BATHROOMS, GARAGES, LAUNDRY AND UTILITY ROOMS MUST BE JA8 HIGH EFFICACY LIGHTING AND AT LEAST ONE FIXTURE MUST HAVE VACANCY SENSORS. (SEC 150.0(K) 2J) 20.OTHER ROOMS MUST HAVE HIGH EFFICACY LIGHTING WITH JAS-20 16 BULBS AND HAVE VACANCY SENSORS OR DIMMERS. CLOSETS AND HALLWAYS UNDER 70 SQUARE FEET ARE EXEMPT. 21.OUTDOOR LIGHTING MUST BE MOUNTED ON THE BUILDING AND BE JA8 HIGH EFFICACY, INCLUDING ON/OFF SWITCH AND HAVE PHOTO-CELL AND MOTION SENSOR, OR PHOTO CONTROL AND AUTOMATIC TIME SWITCH OR ASTRONOMICAL TIME CLOCK OR ENERGY MANAGEMENT CONTROL SYSTEM. 22.AT LAST ONE 20 AMP BRANCH CIRCUIT SHALL BE PROVED TO SUPPLY BATHROOM AND LAUNDRY RECEPTACLE OUTLETS. SUCH CIRCUITS SHALL HAVE NO 0THER OUTLETS. 23.SMOKE DETECTORS AND CARBON MONOXIDE ALARMS SHALL BE INTERCONNECTED AND HARWIRED WITH BATTERY BACKUP (R314,R315) VERIFY WITH OWNER ON ALL ELECTRICAL WIRING & SPECIFICATIONS PRIOR TO INSTALLATIONS. ELECTRICAL NOTES UL 2034/2075 RATED CARBON MONOXIDE ALARM UL 217 RATED SMOKE DETECTOR DUPLEX RECEPTACLE, FLUSH MOUNTED, NEAM 5-20R, 20 AMP. 125 VOLT. +15" MIN. TAMPER RESISTANT TYPE GFCI OUTLET WEATHERPROOF GFCI OUTLET BATHROOM EXHAUST FAN w/50 cfm MIN. & HUMIDISTAT NUSWITCHED RECESSED CAN LIGHT, FLUORESCENT OR LED RATE ELECTRICAL LEGEND SINGLE POLE LIGHT SWITCH, 20A, 250V. THREE-WAY SWITCH FOUR-WAY SWITCH WALL MOUNTED LIGHT FIXTURE FLUORESCENT OR LED RATE MOTION SENSORS VACANCY SENSORS FAN & LIGHT FIXTURE, CEILING MOUNT E-01 SCHEMATIC ELECTRICAL PLAN - FIRST FLOOR Revisions Drawing Title Date: 07/18/2023 Aqx Job No: 2022-628 Drawing No. Drawn: A.B. PROJECT 216 E Balboa Blvd, Newport Beach, CA 92661 DUPLEX & TWO ADU's STUDIO ARCHITECTURAL SCHEMATIC ELECTRICAL PLAN FIRST FLOOR +15 +80 +15 1.ALL LIGHTS SHALL BE HIGH EFFICIENCY. 2.NO VACEY SENSOR OR TIMMER IN CLOSET LESS THAN 70 SQ.FT. 3.ALL 15 & 20-AMP BRANCH CIRCUIT(S) SERVING DWELLING UNIT OUTLETS AND ALL CIRCUITS MUST BE AN ARC-FAULT CIRCUIT INTERRUPTER(S) PROTECTED. 4.VERIFY AT (E) BEDROOM RECEPTACLES ARE TO BE LOCATED IN A WALL EVERY 12 LINEAR FEET SO THAT A FIXTURE WILL NOT BE MORE THAN 6 FEET FROM ANY RECEPTACLE. 5.RECEPTACLES AT THE FRONT AND REAR OF HOME SHALL BE WITHIN 6'-6" OF GRADE. SUCH RECEPTACLES SHALL BE WATERPROOF & GFCI PROTECTED. 6.ALL EXTERIOR LIGHTING SHALL BE WATER PROOF, ALL EXTERIOR ELECTRICAL OUTLETS SHALL BE WATER PROOF AND BE GFI PROTECTED. 7.ALL OUTDOOR LIGHTING SHALL BE HIGH EFFICACY. 8.AT LEAST ONE 20 AMP BRANCH CIRCUIT SHALL BR PROVIDE TO SUPPLY BATHROOM RECEPTACLE OUTLETS. SUCH CIRCUITS SHALL HAVE ON OTHER OUTLETS. 9.GROUND FAULT CIRCUIT INTERRUPTER (GFI) RECEPTACLE PROTECTION IS REQUIRED IN THE BATH, GARAGE, OUTDOORS, UNDER FLOOR SPACE, KITCHEN COUNTERS, UNFINISHED BASEMENTS AND LAUNDRY/UTILITY/WET BAR SINKS (WHERE THE RECEPTACLE IS WITHIN 6 FT OF THE OUTSIDE SINK EDGE). 10.THE KITCHEN IS REQUIRED TO HAVE A MECHANICAL EXHAUST FAN DUCTED TO THE OUTSIDE, THE RANGE HOOD OVER THE STOVE MUST VENT TO THE OUTSIDE WITH A MINIMUM VENTILATION RATE OF 100 CFM AND USE 6"Ø DUCT MIN. THE DUCTING FOR THE EXHAUST FAN SHALL BE SIZED ACCORDING TO ASHRAE STANDARD 62.2 TABLE 7.1. 11.THE LOCAL EXHAUST FANS IN THE BATHROOMS AND KITCHENS WILL DETERMINE THE MIN. VENTILATION RATE PER ASHRAE STANDARD 62.2 EQU. 4.1(a). BATHROOM USE 4"Ø DUCT MIN. SIZE THAT ACCORDING TO ASHRAE STANDARD 62.2 TABLE 7.1 AND THIS EXHAUST FAN SHALL OPERATED CONTINUOUSLY. 12.VERIFY WITH OWNER ON ALL ELECTRICAL WIRING & SPECIFICATIONS PRIOR TO INSTALLATIONS. 13.SPEAKER/ VIDEO CABLE AND PHONE WIRING TO BE SPECIFIED BY OWNER. 14.ALL FAN SYSTEMS EXHAUSTING AIR FROM THE BUILDING ENVELOPE TO THE OUTSIDE SHALL BE PROVIDED WITH BACK-DRAFT DAMPERS. 15.ALL LIGHTING FIXTURES IN THE KITCHEN MUST BE HIGH EFFICACY CONTROLLED BY EITHER A DIMMER SWITCH OR VACANCY SENSOR THAT REQUIRES A MANUAL ON ACTIVATION. UNDER CABINETS LIGHTING REQUIRES SEPARATE SWITCH FROM OTHER LIGHTING SYSTEM. 16.ALL LIGHT FIXTURES SHALL CONTAIN BULBS THAT ARE LABELED AS JAS-2016. SCREW BASE BULBS ARE PERMITTED, EXCEPT IN RECESSED LIGHTING FIXTURES. 17.RECESSED LIGHTING SHALL BE LISTED AS IC (ZERO CLEARANCE TO INSULATION) AND AT (AIR TIGHT), BE SEALED/CAULKED BETWEEN THE FIXTURE HOUSING AND CEILING, SHALL NOT CONTAIN A SCREW BASE SOCKET, AND CONTAIN BULBS MARKED WITH JAS-20 16-E EFFICIENCY LABEL. 18.LIGHTING FIXTURES LOCATED WITHIN 3 FEET HORIZONTALLY AND S FEET VERTICALLY OF THE BATHROOM RIM OR SHOWER STALL THRESHOLD V SHALL BE LISTED FOR A DAMP LOCATION, OR LISTED FOR WET LOCATIONS WHERE SUBJECT TO SHOWER SPRAY. 19.LIGHTING IN BATHROOMS, GARAGES, LAUNDRY AND UTILITY ROOMS MUST BE JA8 HIGH EFFICACY LIGHTING AND AT LEAST ONE FIXTURE MUST HAVE VACANCY SENSORS. (SEC 150.0(K) 2J) 20.OTHER ROOMS MUST HAVE HIGH EFFICACY LIGHTING WITH JAS-20 16 BULBS AND HAVE VACANCY SENSORS OR DIMMERS. CLOSETS AND HALLWAYS UNDER 70 SQUARE FEET ARE EXEMPT. 21.OUTDOOR LIGHTING MUST BE MOUNTED ON THE BUILDING AND BE JA8 HIGH EFFICACY, INCLUDING ON/OFF SWITCH AND HAVE PHOTO-CELL AND MOTION SENSOR, OR PHOTO CONTROL AND AUTOMATIC TIME SWITCH OR ASTRONOMICAL TIME CLOCK OR ENERGY MANAGEMENT CONTROL SYSTEM. 22.AT LAST ONE 20 AMP BRANCH CIRCUIT SHALL BE PROVED TO SUPPLY BATHROOM AND LAUNDRY RECEPTACLE OUTLETS. SUCH CIRCUITS SHALL HAVE NO 0THER OUTLETS. 23.SMOKE DETECTORS AND CARBON MONOXIDE ALARMS SHALL BE INTERCONNECTED AND HARWIRED WITH BATTERY BACKUP (R314,R315) VERIFY WITH OWNER ON ALL ELECTRICAL WIRING & SPECIFICATIONS PRIOR TO INSTALLATIONS. ELECTRICAL NOTES UL 2034/2075 RATED CARBON MONOXIDE ALARM UL 217 RATED SMOKE DETECTOR DUPLEX RECEPTACLE, FLUSH MOUNTED, NEAM 5-20R, 20 AMP. 125 VOLT. +15" MIN. TAMPER RESISTANT TYPE GFCI OUTLET WEATHERPROOF GFCI OUTLET BATHROOM EXHAUST FAN w/50 cfm MIN. & HUMIDISTAT NUSWITCHED RECESSED CAN LIGHT, FLUORESCENT OR LED RATE ELECTRICAL LEGEND SINGLE POLE LIGHT SWITCH, 20A, 250V. THREE-WAY SWITCH FOUR-WAY SWITCH WALL MOUNTED LIGHT FIXTURE FLUORESCENT OR LED RATE MOTION SENSORS VACANCY SENSORS FAN & LIGHT FIXTURE, CEILING MOUNT E-02 SCHEMATIC ELECTRICAL PLAN - SECOND & THIRD FLOORS Revisions Drawing Title Date: 07/18/2023 Aqx Job No: 2022-628 Drawing No. Drawn: A.B. PROJECT 216 E Balboa Blvd, Newport Beach, CA 92661 DUPLEX & TWO ADU's STUDIO ARCHITECTURAL SCHEMATIC ELECTRICAL PLAN SECOND FLOOR SCHEMATIC ELECTRICAL PLAN THIRD FLOOR