HomeMy WebLinkAboutPA2023-0118_20230627_Plans_36x24Stone, Tile, or Brick Veneer
Stud Wall
One Hour Wall
Plywood
Concrete
Batt Insulation
Gas
Hose Bib
Floor Drain
Wall type
Keynote
Door Symbol RE: Door ScheduleSheet A.002
Revision
Room Number
Interior Elevation i.e. Drawing 1A,Sheet A.600
Large Scale Detail i.e. Drawing 1,Sheet A.402
Elevation i.e. Drawing 1,
Sheet A.300
Detail Section i.e. Drawing 1,
Sheet A.700
Building Section i.e. Drawing 1,
Sheet A.400
Window Symbol RE: Window Schedule
Sheet A.002
G
HB
Direction of ViewCut Plane
Sheet NumberSection Number
Sheet NumberDetail Number
Direction of View
Cut Plane
Direction of View
Sheet NumberElevation Number
Sheet NumberDetail Number
Detail Area
Direction of View
Sheet Number
Elevation Number
1
1
1
Project Data
100
1
Architectural Abbreviations
Architectural Symbols
A.700
A.3001
A.7001
1A.400
ROOM NAME
ADJAFF
BDBETW
BLKG
BMCIP
CJ
CL
CLG
CLR
COLCONC
CONST
CONTCRG
DBLDIM
DNDR
DTLDWG
EAELEV.
ELEC
EQEQUIP
EXPEXT
(E)
FCFFL
FLR
FLUORFIN
FOFOS
FOW
FDGA
GALV
GRGWB
GYP BD
HCHD
HMHR
HTINS
INTJT
LEVLT
LOC
Adjacent
Above Finished FloorBoard
BetweenBlocking
BeamCast in Place
Control JointCenterline
Ceiling
ClearColumnConcrete
Construction
ContinuousCorrugated
DoubleDimension
DownDoorDetail
DrawingEach
Elevation
ElectricalEqual
EquipmentExpansion
Exterior
ExistingFire Extinguisher Cabinet
Finish Floor LevelFloor
FlourescentFinish
Face Of
Face of StudFace of Wall
Floor DrainGuage
GalvanizedGrade
Gypsum BoardGypsum Board
Hollow CoreHot Dipped
Hollow MetalHour
HeightInsulation
Interior
JointLevel
LightLocation
MAXMECH
MEMBMFR
MINMTDMTL
MODMR GWB
NFV
NICNO
(N)
OCOPNG
OPPPL
PLT
PLYPT
PTDRADRD
RE:RES
RESILREQ'D
RGDRM
ROROD
RWLSC
SCHED
SECTSHT
SIMSKD. GD.
ST. STL.STRUCT
SUSPTHK
THRUT.O.
TYPUNO
VENVER
VESW/
WDWPWR
WRBWT
Maximum
MechanicalMembrane
ManufacturerMinimum
MountedMetal
ModuleMoisture ResisitantGypsum Board
Net Free Vent. AreaNot in Contract
NumberNewOn Center
Opening
OppositeProperty Line
PlatePlywood
PointPainted
Radius, RadiiRoof Drain
Refer ToResistant
ResilientRequired
RigidRoom
Rough OpeningRolling Overhead Door
Rain Water LitterSolid Core
ScheduleSection
SheetSimilar
Skid GuardStainless Steel
StructuralSuspended
ThickThrough
Top OfTypical
Unless Noted OtherwiseVeneer
VerifyVestibule
WithWood
WaterproofWater Resistant
Water Resistant BarrierWeight
Vicinity Map
101B
2B
1/A.600
1. All construction shall be completed in full compliance with the 2019 California
Building Code (CBC), Electrical (CEC), Energy (T24-6), Mechanical (CMC),Plumbing (CPC) and all other applicable county and state codes and
requirements.
Contractors shall give all notices and comply with all applicable codes and
regulations, laws, ordinances and orders by any public authority havingjurisdiction over the project and shall meet or exceed all industry standards.
2. The Contractors shall study and compare the contract documents and shall atonce report to the architect in writing all errors inconsistencies or omissionsdiscovered and verify all dimensions on site PRIOR TO COMMENCING THE WORK. If
a subcontractor proceeds with any of the work so affected without writteninstructions from the architect, the subcontractor shall make good at his own costany resulting error, damage or defects. The subcontractor shall perform no portion
of the work without contract documents or, where required, approved shopdrawings, product data or samples for such portion of the work.
3. The intent of these drawings is to provide a complete and finished job in all
respects. Contractors are to make accurate field inspections of all aspects of thejob. Extras will not be allowed unless authorized by the owner and architect for
"Authorized Changes and Revisions" to the scope of work.
4. Written dimensions on drawings shall take precedence over dimensions scaledfrom the drawings. All dimensions affecting materials or equipment with specifictolerances shall be verified by the contractor and/or supplier in the field. Minimum
code required clear dimensions shall always be maintained.
5. All dimensions are to face of finish or centerline unless noted otherwise. Finishes atexterior walls cannot encroach on building setbacks.
6. Subcontractors shall check with all equipment manufacturers to verify dimensionsand details prior to commencement of the work. Manufacturors specificrequirements shall always be maintained.
7. Subcontractors shall be responsible for initiating, maintaining and supervising all
safety precaution programs in connection with their work, and for maintainingappropriate insurance to protect the subcontractor, architect and owner.
8. The architect will submit contract documents for "Plan Check" and make any
necessary corrections. The owner will pay for the building permit and attachedfees; charges, fees and assessments levied by public authorities for connection to
public utilities; and the cost of bonds required for insurance of the work relatedconstruction.
9. Contractor shall erect and maintain temporary barricades and dust proofpartitions as needed for protection against accident, and to maintain adequate
protection of his work and the owner's property from damage or loss arising inconnection with any construction. All damage so occurring shall be repaired or
replaced by the responsible subcontractor at no cost to the architect or owner.
10. Contractor shall provide temporary toilet facilities at the job as necessary andrequired by code.
11. Contractor shall slope all decks, patios and walks away from new and existing
structures and verify that all areas affected by construction are positively drained.
12. Exterior trim & plant-ons applied over stucco or framing shall be back primed.
13. Plywood and plywood products used as exterior covering on walls, soffits and inother areas exposed directly to weather shall be exterior grade.
14. Provide min. 70" high hard, non-absorbent wall (Vitreous ceramic tile) adj. to
shower and above the drain inlet. All bathroom floors shall be over minimum 15#felt underlayment. Provide shower specifications per the highest industry
standards. Where showers are flush with floor provide Schluter shower system forwaterproofing and drainage.
15. Water-resistant gypsum backing board shall be used as a base for tile in water
closet compartment walls when installed in accordance with GA-216 or ASTM C840 and manufacturer recommendations. Refer to CBC Sec. 2509.2
16. Plastered surfaces on walls, ceilings and soffits exposed to the weather shall have
exterior lath and plaster conforming to CBC Section 2507 and 2508 respectively,unless exempted by Section 424. Interior plaster reinforced per Section 2507.1 maybe applied over gypsum lath on ceilings and soffits.
17. Studs in exterior walls of rooms with sloping ceilings shall extend from floor to roof
without intermediate plates unless plates are designed. Maximum allowableheight for: 2"x4" is 14 ft. and 2"x6" is 20 ft.
18. No part of the structure shall be overloaded beyond its safe carrying capacity by
the placing of materials, equipment, tools, machinery and any other items.
19. Fireblock stud walls and partitions including furred spaces at floors, ceilings andsoffits at maximum of 10 ft. o.c. horizontally and vertically.
20. Fireblocking shall be provided per CBC Sec. 717. 1. In concealed spaces of stud
walls and partitions, including furred spaces, at the ceiling and floor levels and at10' intervals both vertical and horizontal. 2. At all interconnections between
concealed ver. and hor. spaces such as occur at soffits, drop ceiling and coveceilings. 3. In concealed spaces between stair stringers at the top and bottom ofthe run and between studs along and in line with the run of stairs if the walls under
the stairs are unfinished. 4. In openings around vents, pipes, ducts, chimneys,fireplaces and sim. openings which afford a passage for fire at ceiling and floor
levels, with non-combustible materials. 5. at openings between attic spaces andchimney chases for factory-built chimneys. 6. Where wood sleepers are used forlaying wood flooring on masonry or concrete fire-resistive floors, there should be no
space which will exceed 100 sq.ft.
21. Provide access and ventilation in accordance with CBC Section 2317.7 and asshown on the drawings to crawl spaces and plumbing confirming location with the
architect prior to construction.
22. Protect all finish floor surfaces from damage and equip mobile equipment withpneumatic tires.
23. Plumbing subcontractor shall verify that all copper water supply lines are sized to
provide acceptable pressure and volume and shall connect waste lines to sewerproviding cleanouts and ventilation as required by the California Plumbing Code.Cleanout to be located in inconspicuous locations and coordinate with architect
prior to installation.
24. All metal flashing, gutters and downspouts shall be constructed from min. 16 oz.galvanized sheet metal or copper as noted on the drawings or greater as per
industry standards. Joints shall be lapped, joined and sealed so that they arewatertight in accordance with SMACNA standards and provide for positive water
flow.
25. All glass doors and windows shall be certified and labeled to show compliancewith air infiltration standards of the 1972 ANSI A134.1-4. All new glazing shall complywith standards of the U.S. Consumer Product Safety Commission and
manufactures certificate of compliance shall be supplied to Owner. Final windowand glass product to be verified with Title 24 requirements prior to purchase.
26. Where windows are provided as a means of escape or rescue in all sleeping
rooms, they shall have a minimum clear width when fully open of 20", a min. clearheight when fully open of 24", a min. clear area when fully open of 5.7 sq. ft. and
a min. finished sill height of not more than 44" above finished floor.
27. Every exit door shall be openable from the inside without the use of a key or anyspecial knowledge or effort. Special locking devices shall be of an approved typeper Title 19 and CBC Chapter 10.
28. Provide safety glazing where required including but not limited to glass doors,French doors, adjacent glazed panels and sidelights and all glazed panels andwindows within 18" of the floor or a door opening shall have tempered glass or
glass approved for impact hazard and as defined per CBC
29. All glazing in hazardous locations as defined in CBC Section 2406.4 shall be safetyglass, including:
a. swinging and sliding doors
b. glazing within 24" of doors and within 60" of walking surface
c. one or more walking surfaces within 36" horizontally of the glazing
30. All safety glazing shall conform to Part I of UBC Standard No. 24-2. Polished wireglass complying with Part II of UBC Standard No. 24-2 may be used in fire
assemblies and in locations specified in UBC Section 2406.4 Items 6 and 7.
31. Safety glazing is required at wardrobe doors. Sec. 2406.3
All exterior doors or glazing less than 16 ft. above the grade of any adjoining yard,court, passageway, public way, walk, breezeway, patio, planter, porch, adjoining roof,balcony,landing, stair tread, platform or similar area that is accessible by the publicshall comply with the following security requirements:
1. A single swinging door, active leaf of a pair of doors and the bottom leaf of Dutchdoors shall be equipped with a latch and deadbolt key operated from the outsideand operated from the inside by a device not prohibited by Sec.1008 of the CBC.Straight deadbolts shall have a minimum throw of 1" with a minimum 5/8"embedment. Hook or expanding lug deadbolts shall have a minimum throw of3/4". Bolts of locks which automatically activate two or more deadbolts shall
embed 1/2" minimum.
2. Exterior wood doors shall be minimum 1
34" thick. Hardware must comply withchapter 10 of the CBC.
3. Panels of wood doors shall be not less than
916" thick and not more than 300sq.
inches. Stiles and rails to be 138" thick and 3" minimum width.
4. Door hinge pins accessible from the outside shall be of the non-removable type.
5. Door stops of wood jambs on in-swinging doors shall be one piece constructionwith jamb or joined by rabbet.
6. Windows and door lites within 40" of the locking device of the door shall be fullytempered.
7. Overhead and sliding garage doors shall be secured with a cylinder lock, padlockwith a hardened steel shackle, or equivalent when not otherwise locked byelectric power operation. Jamb locks shall be on both jambs for doors exceeding9 ft. in width.
8. Sliding glass doors and sliding glass windows shall be resistant to forced entry.
9. All glazing where the lowest edge of the material is less than 18" above thewalking surface and the exposed glazing material exceeds 9 sq. ft. shall betempered and as required by the CBC.
10. The strike plate for latches and the holding devices for projecting deadbolts inwood construction shall be secured to the jamb and the wall framing with screwsnot less than 2 1/2" in length.
11. Cylinder guards shall be installed on all cylinder locks whenever the cylinderprojects beyond the face of the door or is otherwise accessible to gripping tools.
12. Sliding doors and windows shall be provided with a device in the upper channelof the moving panel to prohibit raising and removing the moving panel in theclosed or partially open position.
General Notes
Security Notes
32. Provide handrails not less than 34" nor more than 38" above the nosing of tread.
33. Provide an outside gas shutoff valve conspicuously marked per Title 19, Chapters6-9 and the CBC.
34. Provide mechanical ventilation systems in all bathrooms with toilets, showers, andtoilet rooms w/o windows, to furnish a minimum (5) air changes per hour.
35. All posts plates and sleepers etc. bearing on or embedded in concrete or masonryshall be pressure treated Douglas Fir.
36. Smoke detectors shall be provided in all sleeping rooms, hallways giving access to
sleeping rooms, and as required by the CBC.
37. Subcontractors shall provide a one year warranty for their portion of the work andseparate guarantee for specific equipment items. The builder shall supply theowner maintenance informtion for all features, materials, components, andmanufactured devices that require routine maintenance for efficient operation.Required routine maintenance actions shall be clearly stated on a readilyaccessible label. Include names of local representatives to be contacted forservice.
38. Where specified items are called for in the construction documents, theContractor may submit alternate materials for approval by the Owner and theArchitect.
39. Owner will furnish electrical power and water from outlets designated by ownerwithout charge to the contractor for quantities used in the work. Characteristics of
electrical power furnished is limited to that existing and available, if power of othercharacteristics or quantity is required subcontractor shall supply the power at noextra charge to the owner.
40. Subcontractors supplying heating, cooling, water heating, and lighting systemsand conservation or solar devices installed in the building shall provide the ownerinstructions on how to use equipment efficiently. Subcontractor shall provide futureallowance for solar panel installation, including conduit runs, etc. as would berequired.
41. Temporary ingress-egress, stockpiling materials, landscaping, drive approachesand/or utility installation within public right of way requires an encroachmentpermit from the associated property permits division.
42. Provide insulation at all interior walls, provide closed cell Insulation at allfloor/ceilings. Refer to T-24 for exterior wall and roof insulation requirements. Atnon-vented ceilings (both pitched and flat) and attics provide closed cell sprayfoam insulation.
43. A separate permit is required for each building or structure, i.e., fence walls,retaining walls, outdoor or indoor swimming pools/spas, and elevators.
44. Anti-scalding shower and tub valves required. UPC Section 410.7.
45. There shall be a floor or landing on each side of a door. Landings shall be levelexcept for exterior landings, which are permitted to have a slope not to exceed1/4:12 (2% slope). The landing at an exterior doorway shall not be more than 7.75"below the top of the threshold, provided the door, other than an exterior storm or
screen door, does not swing over the landing, 112" maximum if the door does swingover the landing.
46. Foundation walls enclosing a basement shall be dampproofed and orwaterproofed per CBC Section 1806
47. Provide min. 26 ga. galvanized weep screed with minimum 3 1/2" verticalattachment flange at or below the foundation plate line and 4" min. above earthor 2" min. above paved areas. Grade to slope away from building per code req.
48. Chimneys shall extend at least 2 feet higher than any portion of the building within10 feet but shall not be less than 3 feet above the highest point where the chimneypasses through the roof.
49. Walls of fireboxes shall be 10" min. thick; 8" if lined with firebrick. Twelve (12) inchclearance from fire box to combustible face.
51. Provide 4 - No. 4 rebar full height with #2 hoop ties at 18" o.c. with 2 - #2 at offsets.Anchor chimney to building at each ceiling and floor line per UBC Section 2113.
52. All chimneys attached to any appliance or fireplace that burns solid fuel shall beequipped with an approved spark arrestor. The spark arrestor shall meet all of therequirements outlined by CBC 2113.9.1.
53. Factory-built fireplaces, chimneys, and other components shall be listed andinstalled in accordance with their listing and manufacturer instructions.
54. Exterior combustion air ducts shall be listed components of the fireplace, andinstalled according to the fireplace manufacturer's instructions. (CBC 2111.13.1)
55. Decorative shrouds shall not be installed at the termination of factory-builtchimneys except where such shrouds are listed and labeled for use with thespecific factory-built chimney system and are installed in accordance with themanufacturer's installation instructions. (CMC 802.4.2.4)
56. Anchor veneer to studs with wall ties made of corrosion resistant, and if made of
sheet metal, shall have a minimum thickness of 0.030 inch (22 GA) by 34 inch or, ifof wire, shall have a minimum diameter of 0.148 inch (No. 9 B.W. gage). Wall tiesshall be spaced so as to support not more than 2 square feet of wall area but shallnot be more than 24 inches on center horizontally. inch or, if of wire, shall have aminimum diameter of 0.148 inch (No. 9 B.W. gage). In seismic zones 3 and 4, wallties shall have a lip or hook on the extended leg that will engage or enclose a
horizontal joint reinforcement wire having a diameter of 0.148 inch (No. 9 B.W.gage) or equivalent. The joint reinforcement shall be continuous with butt splicesbetween ties permitted. Per min CBC requirements.
With wood stud backing, a 2-inch by 2-inch (51 by 51 mm) 0.0625-inch (1.59 mm)zinc-coated or metalic coated wire mesh with two layers of water-resistive barrierin accordance with Section 1404.2 shall be applied directly to wood studs spaceda maximum of 16 inches (406 mm) o.c. On studs, the mesh shall be attached with2-inch-long (51 mm) corrosion-resistant steel wire furring nails at 4 inches (102 mm)o.c. providing a minimum 1.125-inch (29 mm) penetration into each stud and with8d common nails at 8 inches (203 mm) o.c. into top and bottom plates or withequivalent wire ties. There shall be not less than a 0.1055-inch (2.68 mm)zinc-coated or nonmetallic coated wire, or approved equal, attached to the stud
with a minimum of an 8d (0.120 in. diameter) annular threaded nail for every 2
square feet (0.2 m2) of stone veneer. This tie shall be a loop having legs not lessthan 15 inches (381 mm) in length, so bent that it will lie in the stone veneer mortarjoint. The last 2 inches (51 mm) of each wire leg shall have a right-angle bend.One-inch (25 mm) minimum thickness of cement grout shall be placed betweenthe backing and the stone veneer.
Slab-type veneer units not exceeding 2 inches (51 mm) in thickness shall beanchored directly to masonry, concrete or stud construction. For veneer units ofmarble, travertine, granite or other stone units of slab form ties of corrosion-resistantdowels in drilled holes shall be located in the middle third of the edge of the units,spaced a maximum of 24 inches (610 mm) apart around the periphery of each
unit with not less than four ties per veneer unit. Units shall not exceed 20 square feet
(1.9 m2) in area. If the dowels are not tight fitting, the holes shall be drilled not morethan 0.063 inch (1.6 mm) larger in diameter than the dowel, with the holecountersunk to a diameter and depth equal to twice the diameter of the dowel inorder to provide a tight-fitting key of cement mortar at the dowel locations whenthe mortar in the joint has set. Veneer ties shall be corrosion-resistant metalcapable of resisting, in tension or compression, a force equal to two times theweight of the attached veneer. If made of sheet metal, veneer ties shall be notsmaller in area than 0.0336 by 1 inch (0.853 by 25 mm) or, if made of wire, notsmaller in diameter than 0.1483-inch (3.76 mm) wire.
Provide bituthene behind and against plywood where mechanical attachmentswill occur Fill penetrations w/ Rain Buster 900 by Top Industrial Inc.
57.No trenches or excavations 5' or more in depth into which a person is required todescend, or obtain permit from the State of California, Division of OccupationalSafety and Health (Cal/OSHA).
58. Contractor shall provide pedestrian protection adjacent to the public way asfollows:
Dist. from struct. to Prop Line (SB)Protection
SB<5'Barrier and canopy
SB< (ht of struct/4)Barrier and canopy
(Struct ht/2)>SB>(Struct ht/4)Barrier only
SB>(Struct ht/2)None
59. When required, fence and canopy to be constructed per CBC 3306.5, 3306.6 and3306.7
60. Where pedestrian barrier is not required, provide construction fencing for newconstruction. Fence height to be between 72" and 84" high.
61. Where single family dwellings and duplexes have not been checked for plumbing,mechanical, and electrical code compliance, these disciplines are subject to fieldinspection. Installation and equipment shall meet CBC, CPC, CMC, CEC coderequirements.
62. A licensed surveyor shall complete FEMA elevation certificate and submit it to theBuilding Department Inspector during final inspection.
63. The contractor shall be responsible for all methods and means of construction. Alltrades to follow industry standards, applicable codes and best practices.Contractor to bring to architects attention necessary deviatios or location of visiblecontrol joints, expansion joint etc. prior to installation.
64. Contractor to verify and warrant waterproofing, following or exceeding industrystandards and best practices, including but not limited to flashing, conterflashing,sill head and jamb conditions, gutters, roofing, roof to wall, wall terminations, doorsand windows, building skin, etc.
65. Provide shop drawings and submittals for all visible finish products.
66. Contractor to provide as built/record drawings depicting all deviations fromdrawings and unseen conditions.
67. Contractor shall provide as-built drawings detailing actual locations of concealedwork before final inspection.
68. Obtain fire sprinkler permit prior to calling for roof sheathing inspection.
69. All stairways shall have an illumination level on tread runs of not less than 1 footcandle (11 lux). CBC 1205.4
National Pollutant Discharge (Elimination System)
1. Sediment from areas disturbed by construction shall be retained on site using
structural controls to the maximum extent practicable.
2. Stockpiles of soil shall be properly contained to minimize sediment transport fromthe site to streets, drainage facilities or adjacent properties via runoff, vehicle
tracking, or wind.
3. Appropriate BMP's for construction-related materials, wastes, spills shall beimplemented to minimize transport from the site to streets, drainage facilities, or
adjoining properties by wind or runoff.
4. Runoff from equipment and vehicle washing shall be contained at constructionsites unless treated to reduce or remove sediment and other pollutants.
5. All construction contractor and subcontractor personnel are to be made aware of
the required best management practices and good housekeeping measures forthe project site and any associated construction staging areas.
6. At the end of each day of construction activity all construction debris and waste
materials shall be collected and properly disposed in trash or recycle bins.
7. Construction sites shall be maintained in such a condition that an anticipatedstorm does not carry wastes or pollutants off the site. Discharge of material, other
than stormwater, only when necessary for performance and completion ofconstruction practices and where they do not: cause or contribute to a violationof any water quality standard; cause or threaten to cause pollution,
contamination, or nuisance; or contain a hazardous substance in a quantityreportable under Federal Regulations 40 CFR Parts 117 and 302.
8. Potential pollutants include but are not limited to: solid or liquid chemical spills;
wastes from paints, stains, sealants, glues, lime, pesticides, herbicides, woodpreservatives and solvents; asbestos fibers, paint flakes or stucco fragments; fuels,oils, lubricants, and hydraulic, radiator or battery fluids; fertilizers,
vehicle/equipment wash water and concrete wash water; concrete, detergent orfloatable wastes; wastes from any engine/equipment steam cleaning or chemical
degreasing and super chlorinated potable water line flushing.
9. During construction, permittee shall dispose of such materials in a specified andcontrolled temporary area on-site, physically separated from potential stormwaterrunoff, with ultimate disposal in accordance with local, state and federal
requirements.
10. Dewatering of contaminated groundwater, or discharging contaminated soils viasurface erosion is prohibited. Dewatering of non-contaminated groundwater
requires a National Pollutant Discharge Elimination System Permit from therespective State Regional Water Quality Control Board.
11. Graded areas on the permitted area perimeter must drain away from the face of
slopes at the conclusion of each working day. Drainage is to be directed towarddesilting facilities.
12. The permittee and contractor shall be responsible and shall take necessary
precautions to prevent public trespass onto areas where impounded watercreates a hazardous condition.
13. The permittee and contractor shall inspect the erosion control work and insure that
the work is in accordance with the approved plans.
14. The permittee shall notify all general contractors, subcontractors, materialsuppliers, lessees, and property owners: that dumping of chemicals into the stormdrain system or the watershed is prohibited.
15. Equipment and workers for emergency work shall be made available at all timesduring the rainy season. Necessary materials shall be available on site andstockpiled at convenient locations to facilitate rapid construction of temporary
devices when rain is imminent.
16 All removable erosion protective devices shall be in place at the end of eachworking day when the 5-Day Rain Probability Forecast exceeds 40%.
17. Sediments from areas disturbed by construction shall be retained on site using an
effective combination of erosion and sediment controls to the maximum extentpracticable, and stockpiles of soil shall be properly contained to minimize
sediment transport from the site to streets, drainage facilities of adjacent propertiesvia runoff, vehicle tracking, or wind.
18. Appropriate BMPs for construction-related materials, wastes, spills or residues shall
be implemented and retained on site to minimize transport from the site to streets,
drainage facilities, or adjoining property by wind or runoff.
Project Address:54 Linda IsleNewport Beach, CA 92660
Legal Description: Lot 54 of Tract No. 4003
Assessor's Parcel Number: 050-461-07
Project Description:Existing Single Family Residence to be Demolished
New Single Family Residence
Owner:Gloria Mariman
54 Linda Isle
Newport Beach, CA 92660
Email: nbgloria@sbcglobal.net
Design Professional in Scott Laidlaw - Laidlaw Schultz ArchitectsResponsible Charge:3111 Second Ave. Corona del Mar, CA 92625Phone 949.645.9982 FAX 949.645.9554E-mail: SLaidlaw@LSarchitects.com
Structural Engineer:Shehzad Khaliq - SKA
3456 Golden Poppy Way, Yorba Linda, CA 92886
Phone: 714.572.0172
Email: skhaliq@skaengrs.com
T24:Paul Kandarian - Southland Energy Consultants
361 Calle Borrego, San Clemente, CA 92672
Phone: 949.497.3591
Zone:R-1
Occupancy/Construction:Group R-3/U / Type V-B Sprinklered
Number of Stories: 2
Established Grade:9.52'
Allowable Building Height: 9.52' (est. grade) + 29.00' = 38.52'
Proposed (Maximum) Height 36.50'
Lot Area:5580 sf
Buildable Area:3292.2 sf
FAR (2x Buildable Area): 6584.4 sf
Open Volume Area:15% of Buildable Area Req'd: 493.8 sf
Provided: 600 sf (18.2%)
Area Calculation:
Proposed
First Floor 1863 sf
Second Floor 2128 sf
Total Living Area 3991 sf
Garage Area: 712 sf
Decks: 311 sf
Parking:3 Garage + (E) 2 On-Site
Fire Sprinklers:Yes
General Notes
City of Newport Beach Notes
1. Issuance of a building permit by the City of Newport Beach does not relieveapplicants of the legal requirements to observe covenants, conditions andrestrictions which may be recorded against the property or to obtain plans. Youshould contact your community associations prior to commencement of anyconstruction authorized by this permit.
2. Pools, spas, walls, fences, patio covers and other freestanding structures requireseparate reviews and permits
3. Fences, hedges, walls, retaining walls, guardrails and handrails or anycombination thereof shall not exceed 42 inches from existing grade prior toconstruction within the required front yard setback area(s)
4. Demolition beyond the approved scope of work requires planning divisionapproval prior to commencement of work. Approval of revisions to project plansare not guaranteed. Any changes in the current scope of work may require theentire structure to be demolished and redeveloped in conformance with thecurrent Zoning Code Development Standards
5. After demolition and prior to framing, the architect of record shall certify that lessthan 50% of exterior walls have been removed and will require replacement. If it isdetermined that 50% or more of exterior walls have been removed duringconstruction, all project work shall cease and the project shall be subject toapplicable requirements of the Zoning Code and Local Coastal ProgramImplementation Plan, which may include, but are not limited to , a Coastaldevelopment Permit and/or other discretionary application. The applicantunderstands that this may result in project delays or denial and possibleeconomic hardship.
6. The maximum time to complete construction on a project is limited to three yearsfrom the date of the permit for all permits issued after August 21, 2019 as requiredby NBMC Section 15.02.095
7. Provide a project information sign for projects requiring fencing (new structure oraddition and remodel to an existing structure with a combined floor areaexceeding seventy-five (75) percent of the floor area of the proposed structure)in designated "High Density Areas". Project sign shall comply with NBMC Section15.60.030.
8. A licensed surveyor shall complete a FEMA Elevation Certificate (EC) and submitthe EC for review and approval from the City's Community Rating System (CRS)Coordinator prior to requesting final inspection.
9. An approved EC must be submitted to the Building Department Inspector duringfinal inspection.
10.All mechanical, gas, and electrical equipment servicing the building (includingducts) must be at least one foot above the BFE (NAVD88).
Applicable Codes
·2022 California Building Code
·2022 California Residential Code
·2022 California Electrical Code
·2022 California Mechanical Code
·2022 California Plumbing Code
This project shall comply with the followingstate codes and all local amendments:
·2022 California Fire Code
·2022 California Energy EfficiencyStandards Code
·2022 California Green Building
Standards Code (CALGreen)
FD
DATE ISSUE/REVISION REVIEW
DRAWING DESCRIPTION
PROJECT
All drawings and written material appearingherein constitute original and unpublishedwork of the architect and may not beduplicated, used or disclosed without thewritten consent of Laidlaw Schultz Architects.
3111 Second AvenueCorona del Mar, CA 92625-2322(949) 645-9982 Fax: (949) 645-9554www.LSarchitects.com
SHEET NO.
Architectural
General Notes A.001
Construction Min. Stds. A.001aCAL Green Standards A.001b
Specifications A.001c-dCost Valuation A.001e
Fireplace Spec.A.001fDoor & Window Sched. A.002 - A.003
Site Plan A.100Floor Plans A.200 - A.201
Roof Plan A.202Perimeter Demo Exhibit A.210 - A.211
Elevations A.300 - A.301SectionsA.400 - A.401
Reflected Ceiling Plans A.500 - A.501
Details A.700 - A.702
List of Drawings Civil
Topographic Survey 1 of 1Drainage Plan C1
Construction Pollution C2Prevention Plan
Structural
Gen.Notes + Shear Sch. SN-1
Special Inspect. & Obs. SN-2
Typ. Concrete Details ST-1Typ. Wood Details ST-2
Foundation Plan S1Second Floor Framing Plan S2
Roof Framing Plan S3High Roof Framing Plan S4
Details SD-1 - SD-4
Landscape
Hardscape Plan L-1
Planting Plan L-2
Deferred Submittals
1. Deferred submittals to be reviewed by project architect or engineer of record and
certified prior to submittal for plan check or approval by the City.1.1. Modifications to existing fire sprinkler system shall be reviewed as deferred
submittal.1.2. AC type
1.3. Sound Attenuation design for HVAC equipment per ARI Std. 275 and Sec.10.26.045 NBMC.
DATE ISSUE/REVISION REVIEW
DRAWING DESCRIPTION
PROJECT
All drawings and written material appearingherein constitute original and unpublishedwork of the architect and may not beduplicated, used or disclosed without thewritten consent of Laidlaw Schultz Architects.
3111 Second AvenueCorona del Mar, CA 92625-2322(949) 645-9982 Fax: (949) 645-9554www.LSarchitects.com
SHEET NO.
Minimum Construction Requirements1
Construction Minimum Standards
DATE ISSUE/REVISION REVIEW
DRAWING DESCRIPTION
PROJECT
All drawings and written material appearingherein constitute original and unpublishedwork of the architect and may not beduplicated, used or disclosed without thewritten consent of Laidlaw Schultz Architects.
3111 Second AvenueCorona del Mar, CA 92625-2322(949) 645-9982 Fax: (949) 645-9554www.LSarchitects.com
SHEET NO.
Cal-Green Residential Minimum1
Cal-Green Notes
High-Density Construction Noise Acknowledgement2
DATE ISSUE/REVISION REVIEW
DRAWING DESCRIPTION
PROJECT
All drawings and written material appearingherein constitute original and unpublishedwork of the architect and may not beduplicated, used or disclosed without thewritten consent of Laidlaw Schultz Architects.
3111 Second AvenueCorona del Mar, CA 92625-2322(949) 645-9982 Fax: (949) 645-9554www.LSarchitects.com
SHEET NO.
4.4
4.10 THE GENERAL CONTRACTOR WILL NOT BE ENTITLED TO EXTRAS FOR OPENING ANY
LOCAL BUILDING CODES. LOCATIONS SHALL BE COORDINATED WITH ARCHITECT REQUIRED FOR MECHANICAL, ELECTRICAL AND PLUMBING INSTALLATIONS PER4.9 THE GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL ALL ACCESS PANELS AS
CONTRACTOR'S SHOP DRAWINGS. ALL OPENINGS SHALL BE PROPERLY SEALED FOR
AND BELOW HUNG CEILINGS. THESE ARE TO BE COORDINATED WITH H.V.A.C. PARTITIONS FOR DUCT WORK. RETURN AIR OPENINGS AND GRILL OPENINGS ABOVE4.8 THE GENERAL CONTRACTOR SHALL PROVIDE SUFFICIENT FRAMING FOR ALL WALL
BUILDING CODES. CONTRACTOR TO COORDINATE WITH ENGINEERING DRAWINGS AND IN FIRE RATED WALLS SHALL HAVE FIRE DAMPERS AS REQUIRED BY GOVERNING WALLS SHALL NOT COMPROMISE THE ACOUSTICAL INTEGRITY OF THE WALLS. OPENINGSAS SHOWN ON ENGINEERING DRAWINGS. OPENINGS IN SOUND ATTENUATED SLAB PARTITIONS ABOVE HUNG CEILINGS TO MATCH AREA CALCULATION REQUIREMENTS
4.5 THE GENERAL CONTRACTOR SHALL USE CORNER BEADS AT ALL EXPOSED CORNERS
4.3 UNLESS OTHERWISE NOTED, ALL DIMENSIONS FOR PARTITIONS ARE FROM FINISH TO
THE FINISH FLOOR OF ALL PARTITIONS FOR THE OWNER'S REPRESENTATIVES REVIEW.4.2 THE GENERAL CONTRACTOR SHALL PROVIDE ALL TIME AND GRADE MARKINGS ON
4.1 THE GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL ALL PARTITIONS AS
6.17 UNLESS OTHERWISE NOTED, ALL LIGHT SWITCHES, THERMOSTATS AND CONTROL
6.16 UNLESS OTHERWISE NOTED, ALL TELEPHONE,DATA AND POWER OUTLETS SHALL BE
6.15 ALL NEW OUTLETS ON COLUMNS WILL BE CENTERED ON FACE SHOWN, UNLESS
LOCATED AS DIMENSIONED ON ARCHITECT'S PLANS, UNLESS OTHERWISE NOTED.6.14 ALL ELECTRICAL AND TELEPHONE RECEPTACLES AND LIGHT FIXTURES SHALL BE
6.13 WHERE MORE THAN ONE SWITCH OCCURS IN THE SAME LOCATION, THEY SHALL BE
6.12 THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL TEMPORARY LIGHTING AND
REQUIREMENTS WITH THE TENANT SUPPLIED TELEPHONE/DATA CONTRACTOR IF
6.10 THE ELECTRICAL CONTRACTOR SHALL COORDINATE ANY ELECTRICAL OR LIGHTING
6.9 THE ELECTRICAL CONTRACTOR SHALL SUBMIT CUTS OF ALL FIXTURES FOR REVIEW
DRAWINGS. ANY DISCREPANCIES WILL BE BROUGHT TO THE OWNER'S OTHER OBSTRUCTIONS TO ASSURE THE FINISHED CEILING HEIGHT SHOWN ON AND CEILING PLENUM CONDITIONS FOR CLEARANCE OF DUCTWORK, LIGHTING AND6.7 THE GENERAL AND ELECTRICAL CONTRACTORS SHALL CHECK ALL CEILING HEIGHTS
6.6 ALL EXISTING RELOCATED AND EXISTING TO REMAIN FLUORESCENT FIXTURES
(INCLUDING NEW LAMPING) OF TYPES AND MANUFACTURERS AS INDICATED ON
6.5 PROPOSALS SHALL BE BASED UPON FURNISHING AND INSTALLING NEW LIGHTING
HAS BEEN ESTABLISHED FOR THE PARTICULAR TYPE OF MATERIAL IN QUESTION, UNDERWRITERS LABORATORIES, INC. IN EVERY CASE WHERE SUCH A STANDARD
6.4 ALL NEW MATERIALS REQUIRED SHALL CONFORM WITH THE STANDARDS OF THE
OF THE LOCAL MUNICIPALITY'S ELECTRICAL CODE AND ALL OTHER AUTHORITIES6.3 THE WORK SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE REQUIREMENTS
ELECTRICAL WORK AS SHOWN OR IMPLIED ON ALL DRAWINGS AND NOTES.6.1 THE CONTRACTOR SHALL FURNISH AND INSTALL ALL LIGHTING FIXTURES AND
5.13 THE GENERAL CONTRACTOR WILL NOT BE ENTITLED TO EXTRAS FOR OPENING ANY
5.9 CEILINGS IN CLOSETS SHALL BE OF THE SAME HEIGHTS AND CONSTRUCTION AS
CONTRACTOR'S ENGINEERS AND BY AUTHORITIES HAVING JURISDICTION TO ENSURE AND ELECTRICAL) SHALL BE INSPECTED AND WHERE REQUIRED, TESTED BY5.6 PRIOR TO CLOSING UP ANY CEILING, ALL PLENUM SYSTEMS (H.V.A.C, PLUMBING,
BUILDING CODES, COORDINATE LOCATIONS WITH THE OWNER'S REPRESENTATIVE PRIOR HANDLING UNITS, PHONE AND ELECTRICAL CONTROLS AS REQUIRED BY LOCAL PANELS IN GYPSUM BOARD CEILINGS AS REQUIRED TO FURNISH ACCESS TO ALL AIR5.5 THE GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL ALL CEILING ACCESS
CONTRACTORS, AND THE TELEPHONE COMPANY WHENEVER THEIR RESPECTIVE
5.4 THE GENERAL CONTRACTOR'S CEILING CONTRACTOR SHALL CLOSELY COORDINATE
DEVIATION FROM HEIGHTS SHOWN WILL BE SUBMITTED TO ARCHITECT FOR REVIEW.5.3 HUNG CEILING HEIGHTS SHALL BE AS SHOWN ON DRAWINGS AND DETAILS ANY
MECHANICAL DUCTS, PIPING OR OTHER EQUIPMENT SHALL BE FORMED OF GYPSUM
5.2 FASCIAS OR ANY BREAK IN THE CEILING HEIGHTS CREATED BY THE INSTALLATION
UNLESS OTHERWISE NOTED. CENTER LINE OF WALL EQUALS CENTER LINE OF4.12 ALL WALL DIMENSIONS ARE FINISHED FACE OF WALL TO FINISHED FACE OF WALL
REQUIRED DEVIATION FROM CONSTRUCTION DIMENSIONS OR CLEARANCES AS PRIOR TO INSTALLATION OF TRACK. ARCHITECT IS TO BE NOTIFIED OF ANY4.11 THE OWNER'S REP. SHALL HAVE THE RIGHT TO REVIEW AND APPROVE ALL CHALK LINES
DEVICES SHALL BE 42" ABOVE FINISH FLOOR.
BY THE OWNER'S REPRESENTATIVE.
INSTALLED IN GANG TYPE BOX UNDER ONE COVER PLATE.
ELECTRICAL SERVICE FOR ALL TRADES AS REQUIRED.
6.11 THE ELECTRICAL CONTRACTOR SHALL COORDINATE ANY TELEPHONE/DATA
INSTALLATION INTO CABINETWORK WITH CABINET CONTRACTOR IF AND AS
CENTERED WITHIN THE BASE BOARD.
OTHERWISE NOTED.
REQUIRED.
AND AS REQUIRED.
ALL PROJECTING PLUMBING,FLOOR ELECTRICAL/TELEPHONE OUTLETS, AND ALL2.10 THE GENERAL CONTRACTOR SHALL CAP AND FLUSH OFF BEHIND FINISH SURFACES
2.11 UPON COMPLETION OF THE DEMOLITION WORK, THE GENERAL CONTRACTOR SHALL
2.9 THE GENERAL CONTRACTOR SHALL FURNISH A SYSTEM OF TEMPORARY LIGHTS
CEILING TILE, PUBLIC TOILETS, ELEVATORS, DOORS, BUCKS, ELECTRICAL AND AIR
2.8 THE GENERAL CONTRACTOR SHALL AT ALL TIMES PROTECT THE PROPERTY OF THE
WALL DEMOLITION, INCLUDING SWITCH BOXES, PLATES, BRIDGES, OR ANY OTHER2.5 THE GENERAL CONTRACTOR SHALL REMOVE FROM PREMISES CONDUITS LEFT AFTER
2.4 ALL WORK DEMOLISHED SHALL BE REMOVED FROM THE PREMISES EXCEPT ITEMS
2.3 THE GENERAL CONTRACTOR SHALL EXECUTE ALL WORK WITHIN THE REGULATIONS
INVENTORY LIST OF ALL ITEMS THAT CAN BE REUSED AND/OR STORED IN BUILDING2.2 THE GENERAL CONTRACTOR SHALL FURNISH THE OWNER'S REP. WITH A COMPLETE
REQUIRED TO COMPLETE DEMOLITION AND REMOVAL OF ALL ITEMS INDICATED IN
OTHER PROJECTING ITEMS WHICH ARE BEING ABANDONED.
PROVIDE THAT ALL AREAS BE LEFT BROOM CLEAN.
THROUGHOUT THE SPACE UNDER CONSTRUCTION AS REQUIRED.
CONDITIONING EQUIPMENT, CONVECTOR ENCLOSURES, ETC.
BUILDING OWNER, INCLUDING BUT NOT LIMITED TO, WINDOWS, FLOOR AND
TELEPHONE OR ELECTRICAL, WIRING AND EQUIPMENT.
TO BE REUSED OR RETURNED TO OWNER OR AS OTHERWISE NOTED.
OF THE BUILDING FOR DEMOLITION AND REMOVAL OF DEBRIS, INCLUDING
DRAWINGS OR AS OTHERWISE DIRECTED BY THE OWNER'S REPRESENTATIVE.
2.1 THE GENERAL CONTRACTOR SHALL FURNISH ALL LABOR AND MATERIAL AS
STOCK.
OVERTIME WORK REQUIRED.
REPRESENTATIVE'S ATTENTION PRIOR TO FINAL BIDDING.
6.8 ALL RECESSED FIXTURES SHALL BE SET FLUSH INTO CEILINGS.
SHALL BE REFURBISHED AS REQUIRED, CLEANED, RE-LAMPED.
FIXTURES AND REMOVING AND REINSTALLING EXISTING LIGHTING FIXTURES
UNLESS OTHERWISE NOTED.
6.2 THE CONTRACTOR SHALL COORDINATE HIS WORK WITH MANUFACTURER'S
REFLECTED CEILING PLAN
SPECIFICATIONS.
HAVING JURISDICTION.
COMPUTER DATA SYSTEMS INDICATED IN THIS SET OF DOCUMENTS. CEILINGS TO INSTALL TELEPHONE SYSTEMS, SECURITY SYSTEMS OR
REGISTERS, AND DIFFUSERS AND OTHER INSERTED ITEMS. PROVISIONS IN ACOUSTICAL WORK AS REQUIRED FOR LIGHTING FIXTURES,5.10 THE GENERAL CONTRACTOR SHALL PROVIDE CUTOUTS AND OTHER SPECIAL
THAT OF ADJOINING SPACE, EXCEPT AS OTHERWISE NOTED.
THE OWNER OR OTHERS, WITH THE MANUFACTURER OR SUPPLIER PRIOR TO THE LOCATION AND CHARACTERISTICS OF ALL WORK AND/OR EQUIPMENT SUPPLIED BY
1.38 INSURANCE AND BONDING FOR THE PROJECT SHALL BE AS DIRECTED BY AND TO
GLAZING, ALL WINDOW SASHES SHALL BE INSPECTED BY THE CONTRACTOR AND1.37 THE GENERAL CONTRACTOR SHALL REPLACE ALL BROKEN OR CRACKED WINDOW
ALTERNATE FOR APPROVAL BY THE OWNER'S REPRESENTATIVE AS WELL AS TO
1.45 WHERE SPECIAL ITEMS REQUIRE EXTENDED LEAD TIME PREVENTING INSTALLATION
1.44 ALL ASSEMBLIES OR DETAILS MARKED AS ALTERNATES TO BASE REQUIREMENTS TO
1.43 MANUFACTURERS NAME, TRADEMARK, LOGOS, ETC., SHALL NOT BE VISIBLE TO THE
COORDINATION OF WORK WHEN COMPLETE SETS ARE NOT AVAILABLE TO SUB- COMPLETE SETS OF WORKING DRAWINGS OR ASSUME FULL RESPONSIBILITY FOR1.42 THE GENERAL CONTRACTOR SHALL SEE THAT ALL SUB-CONTRACTORS RECEIVE
PREPARE PRICING FOR POSSIBLE TEMPORARY ASSEMBLIES.
BY PROJECTED MOVE-IN DATE, CONTRACTOR IS TO PROPOSE AN AVAILABLE
PUBLIC.
BE PRICED INDIVIDUALLY.
CONTRACTORS.
1.39 THE GENERAL CONTRACTOR SHALL VERIFY SIZE, ELECTRICAL REQUIREMENTS,
THE SATISFACTION OF THE OWNER.
ALL INOPERABLE CONDITIONS SHALL BE REPAIRED.
START OF RELATED WORK.
THEIR PROPER INSTALLATION AND FUNCTION.
HIS WORK WITH THAT OF THE CABINET, PLUMBING, H.V.A.C., ELECTRICAL
WALLBOARD ON FURRING CHANNELS.
AND/OR ALTERATION OF HEATING, VENTILATING, AIR CONDITIONING OR
WORK IS CONTIGUOUS.
TO FINAL INSTALLATION. ATTIC ACCESS PANELS SHALL BE IN DISCRETE LOCATIONS.
COMPUTER DATA SYSTEMS INDICATED IN THIS SET OF DOCUMENTS. PARTITIONS TO INSTALL TELEPHONE SYSTEMS, SECURITY SYSTEMS OR
PRIOR TO FINAL INSTALLATION.
SOUNDPROOFING AND VIBRATION.
ENGINEERING DRAWINGS AND THE GENERAL CONTRACTOR'S MECHANICAL
MULLION UNLESS OTHERWISE NOTED.
DESIGNATED ON PLAN OR OF ANY APPARENT CONSTRUCTION CONFLICTS.
OBSTRUCTIONS AND IMPEDIMENTS FOR UNOBSTRUCTED EGRESS IN THE CASE OF THE EXIT INTO THE STREET SHALL CONTINUOUSLY BE MAINTAINED FREE FROM ALL1.33 ALL REQUIRED EXITS, WAYS OF APPROACH THERETO, AND WAYS OF TRAVEL FROM
ANY MISSING PARTS REPLACED BY THE GENERAL CONTRACTOR TO ACHIEVE A WHERE REQUIRED, ANY LOOSE ITEMS TIGHTENED (CEILING EXIST SIGNS, ETC.) AND
SHALL SUBMIT CERTIFICATES TO OWNER'S REP. UPON COMPLETION OF WORK,
FINISHED FIRST CLASS INSTALLATION AND APPEARANCE.
1.32 ALL EXISTING APPURTENANCES NOT BEING REMOVED SHALL BE REFURBISHED
- BOARD OF FIRE UNDERWRITERS.
- DEPARTMENT OF WATER SUPPLY, GAS & ELECTRICITY
(b) ELECTRICAL, PLUMBING AND AIR CONDITIONING CERTIFICATES
(a) FIREPROOF WOOD TEST REPORT (IF REQUIRED)
INCLUDING BUT NOT LIMITED TO THE FOLLOWING:
1.31 THE GENERAL CONTRACTOR, SUB-CONTRACTOR AND TENANT'S CONTRACTORS
FIRE OR OTHER EMERGENCY.
ISSUED BY:
INFORM ARCHITECT OF DISCREPANCIES PRIOR TO BID PROCESS.
4.7 THE GENERAL CONTRACTOR SHALL SUPPLY ALL AIR OPENINGS IN SLAB TO
SPECIFICATIONS AND AS REQUIRED BY STATE AND LOCAL CODES.4.6 ALL PARTITIONS SHALL BE ANCHORED FIRMLY AS PER MANUFACTURER'S
AND EXPOSED ENDS IN PLASTER AND DRYWALL PARTITIONS.
DESIGNATED ON ARCHITECT DRAWINGS.
FINISH.
7.9 ALL DUCT WORK SHALL BE INSULATED AS REQUIRED FOR THERMAL AND ACOUSTIC
7.8 BALANCING OF ENTIRE SYSTEM SHALL BE DONE BY A QUALIFIED ENGINEER.
THE GOVERNING CODE. PLANS SHOWING MECHANICAL VENTILATION SYSTEM7.5 INTERIOR SPACES SHALL BE MECHANICALLY CONDITIONED IN ACCORDANCE WITH
PROPER ASSEMBLY. CEILING DIFFUSERS TO BE RELOCATED TO MAINTAIN NEW7.4 INSTALLATION SHALL BE COORDINATED WITH ALL TRADES AS REQUIRED FOR
SHALL BE SUBMITTED TO THE OWNER'S REP FOR REVIEW PRIOR TO PROCEEDING WITH7.3 SHOP DRAWINGS OF ALL REGISTERS INCLUDING ACCESS PANELS IF REQUIRED,
H.V.A.C. WORK DURING INSTALLATION AND SHALL INSPECT ALL SYSTEMS FOR PROPER7.2 THE H.V.A.C. CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD SUPERVISION OF ALL
7.1 THE GENERAL CONTRACTOR SHALL PROVIDE ALL HEATING, VENTILATING AND AIR
SINGLE CIRCUIT WITH A SINGLE OUTLET SEPARATE FROM ALL OTHER CIRCUITS AND6.27 AS IT RELATES TO THIS SET OF DOCUMENTS, A SEPARATE CIRCUIT (SC) SHALL BE A
CONSIDERATIONS. REF. NOTE 4.7 FOR ADDITIONAL INFORMATION.
SUBMIT REPORT TO THE OWNER'S REPRESENTATIVE.
WILL BE FILED IN ACCORDANCE WITH THE RULES OF THE BUILDING
FABRICATION AND/OR INSTALLATION OR RELOCATION.
OPERATIONS AT COMPLETION OF JOB.
CONDITIONING WORK AS REQUIRED.
USED TO ISOLATE A SINGLE SPECIFIC PIECE OF EQUIPMENT.
7.6 OMITTED
DEPARTMENT.
FIXTURE PATTERNS.
6.26 AS IT RELATES TO THIS SET OF DOCUMENTS, A DEDICATED CIRCUIT (DC) SHALL BE
CONDITIONING ENGINEER AND CONTRACTOR PRIOR TO EXECUTING HIS WORK.6.25 THE ELECTRICAL CONTRACTOR WILL COORDINATE HIS WORK WITH THE AIR
6.23 CONVENIENCE RECEPTACLES SHALL BE BUILDING STANDARD DUPLEX TYPE RATED
COVER PLATES TO MATCH BUILDING STANDARD, UNLESS OTHERWISE NOTED.6.22 PROVIDE NEW BLANKCOVER PLATES FOR EXISTING OUTLETS NOT BEING USED.
AND PATCHING OF ALL CHASES IN FLOORS, WALLS, AND CEILINGS, AS REQUIRED.6.21 THE ELECTRICAL AND/OR GENERAL CONTRACTOR SHALL PROVIDE ALL CUTTING
6.20 ALL ELECTRICAL AND TELEPHONE WIRING CONDUIT SHALL BE CONCEALED IN
AND ALL NECESSARY CONDUIT RUNS TO TELEPHONE EQUIPMENT AS REQUIRED.6.19 PROVIDE TELEPHONE OUTLETS (WHERE SHOWN ON "ELECTRICAL/TELEPHONE PLAN")
6.18 UNLESS OTHERWISE NOTED, ALL OUTLETS SIDE BY SIDE SHALL BE 6" FROM CENTER
A SINGLE CIRCUIT WITH OUTLETS DEDICATED TO SPECIFIC EQUIPMENT
6.24 THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL POWER WIRING.
15 AMP., 125 V., GROUNDED TYPE, UNLESS OTHERWISE NOTED.
PARTITIONS AND/OR CEILING.
OF PLATE WITH POSITIONING DIMENSION CENTERED BETWEEN.
USAGE.
1.30 THE GENERAL CONTRACTOR UPON ACCEPTANCE AND APPROVAL OF THE DRAWINGS ASSUMES FULLRESPONSIBILITY FOR THE CONSTRUCTION, MATERIALS, AND WORKMANSHIP OF THE WORK DESCRIBEDIN THESE NOTES AND DRAWINGS, AND HE WILL BE EXPECTED TO COMPLY WITH THE SPIRIT AS WELL AS
THE LETTER IN WHICH THEY WERE WRITTEN.
1.29 THE GENERAL CONTRACTOR SHALL MAINTAIN A COMPLETE SET OF CONSTRUCTION DRAWINGS ONSITE DURING ALL PHASES OF CONSTRUCTION FOR USE OF ALL TRADES.
1.28 THE CONSTRUCTION NOTES AND/OR DRAWINGS ARE SUPPLIED TO ILLUSTRATE THE DESIGN INTENT AND
THE GENERAL TYPE OF CONSTRUCTION DESIRED, AND ARE INTENDED TO APPLY TO THE FINEST QUALITYOF CONSTRUCTION, MATERIAL AND WORKMANSHIP THROUGHOUT.
1.27 THE GENERAL CONTRACTOR SHALL INCLUDE IN HIS ESTIMATE ALL COSTS (INCLUDING OVERTIMEWORK) FOR REMOVAL, NEW INSTALLATION AND REINSTALLATION WORK FOR ANY PLUMBING, CEILING
(TAKE-DOWN AND REINSTALLATION), ELECTRICAL, TELEPHONE COMMUNICATIONS EQUIPMENT ORHVAC WORK ON CEILING PLENUM.
1.26 THE GENERAL CONTRACTOR SHALL PROVIDE ALL NECESSARY PROTECTION FOR HIS WORK UNTIL
TURNED OVER TO THE CLIENT.
1.25 THE GENERAL CONTRACTOR SHALL PROPERLY PROTECT THE ADJOINING PROPERTY OR WORK ANDANY DAMAGE TO SAME CAUSED BY HIS WORK OR WORKMEN MUST BE MADE GOOD WITHOUT DELAY.
PATCHING AND REPLACING OF DAMAGED WORK SHALL BE DONE BY THE CONTRACTOR WHO ISRESPONSIBLE FOR THE DAMAGE.
1.24 THE GENERAL CONTRACTOR SHALL EXERCISE STRICT DUST CONTAINMENT CONTROL OVER JOB TO
PREVENT DIRT OR DUST FROM LEAVING THE JOB SITE.
1.23 ALL WOODWORK, BLOCKING, GROUNDS, ETC., TO BE FIRE RETARDANT TREATED.
1.22 THE GENERAL CONTRACTOR SHALL SUBMIT ALL FABRICATION SHOP DRAWINGS AND FIXTURE CUTS TO
OWNER'S REP. FOR REVIEW. HE SHALL PROVIDE TWO (2) SETS OF BLUELINES AND ONE (1) SET OFREPRODUCIBLE PAPER SEPIAS. OWNER'S REP. SHALL HAVE FORTY (40) WORKING HOURS (10-DAY)
SHOP DRAWING TURN-AROUND TIME FROM DATE OF RECEIPT. ALL SHOP DRAWINGS AND CUTSSIGNED "REVIEWED" SHALL SUPERSEDE ORIGINAL DRAWINGS IN DESIGN APPEARANCE ONLY.
CONTRACTORS SHALL ASSUME RESPONSIBILITY FOR ERRORS IN THEIR DRAWINGS. THE GENERALCONTRACTOR SHALL FURNISH ARCHITECT SHOP DRAWING SCHEDULE OF SUBMITTALS PRIOR TO
SUBMISSION OF SHOP DRAWINGS.
1.21 THE GENERAL CONTRACTOR SHALL HAVE TEN (10) WORKING DAYS FROM AWARD OF THE CONTRACT
TO SUBMIT SUBSTITUTIONS OR SPECIFIED PRODUCTS OR WORK FOR REVIEW BY ARCHITECT. HE SHALLINCLUDE CUT SHEETS WITH SPECIFICATIONS AND REASONS FOR SUBSTITUTION. OWNER'S REP. SHALL
RESPOND IN TEN (10) WORKING DAYS TO SUBMITTAL. NO SUBSTITUTIONS SHALL BE ACCEPTED AFTERTHE INITIAL TIME LIMIT HAS PASSED.
1.20 THE GENERAL CONTRACTOR SHALL SUPPLY CUT SHEET SPECIFICATIONS OF ALL FIXTURES AND
EQUIPMENT CALLED FOR ON DRAWINGS, I.E., LIGHT FIXTURES, HARDWARE, ETC.
1.19 WHERE THE TERMS "APPROVED EQUAL", "OTHER APPROVED", "EQUAL TO", "ACCEPTABLE" OF THE OTHER
GENERAL QUALIFYING TERMS ARE USED IN THESE NOTES, IT SHALL BE UNDERSTOOD THAT REFERENCE ISMADE TO THE RULING AND JUDGMENT OF THE OWNER'S REPRESENTATIVE.
1.18 THE USE OF THE WORDS "PROVIDE" OR "PROVIDED" IN CONNECTION WITH ANY ITEM SPECIFIED, ISINTENDED TO MEAN, UNLESS OTHERWISE NOTED, THAT WHICH SHALL BE FURNISHED AND INSTALLED
AND CONNECTED WHERE SO REQUIRED.
1.17 THE GENERAL CONTRACTOR SHALL REMOVE ALL RUBBISH AND WASTE MATERIALS, BOTH FROM HISOWN AND OTHER SUB-CONTRACTORS EMPLOYEES, INCLUDING THAT RUBBISH WHICH IS A
BY-PRODUCT OF CARPET AND CABINET INSTALLATION, TELEPHONE COMPANY INSTALLATION, ETC.,AND PROVIDE FOR ITS REMOVAL FROM THE SITE.
1.16 THE GENERAL CONTRACTOR, HIS SUB-CONTRACTOR, AND ANY OTHER CONTRACTOR INVOLVED IN
THIS PROJECT SHALL TAKE NOTE THAT ANY COST CAUSED BY DEFECTIVE OR ILL-TIMED WORK, AS ARESULT OF, BUT NOT LIMITED TO INFERIOR WORKMANSHIP OR MATERIALS, IMPROPER SCHEDULING OR
DELINQUENT ORDERING SHALL BE BORNE BY THE PARTY RESPONSIBLE THEREFORE.
(c)ALL CHARGES INVOLVING THE INSTALLATION AND/OR OPERATION OF A HOIST SYSTEM, IFREQUIRED, SHALL BE BORNE BY THE CONTRACTOR USING THE SYSTEM. CHARGES INVOLVING THE
TEMPORARY REMOVAL AND REINSTALLATION OF WINDOW SASH AND/OR FIXED PANELS REQUIREDFOR DELIVERY SHALL BE BORNE BY THE CONTRACTOR.
(b)BUILDING CONDITIONS, INCLUDING SIZE AND LOADING CAPACITY OF ELEVATORS, SIZE OFDOORWAYS, CORRIDORS, WINDOW OPENINGS, ETC., SHALL BE CHECKED FOR TIMES BEINGDELIVERED BY CONTRACTOR REQUESTING DELIVERY.
(a)DATE AND TIME OF DELIVERY SHALL BE ESTABLISHED IN CONJUNCTION WITH THE
PERSON HAVING JURISDICTION OVER PREMISES. (OVERTIME CHARGES AND/OR ANY
NECESSARY EXPENSE SHALL BE PAID BY CONTRACTOR REQUIRING SERVICE.)
1.15 EACH CONTRACTOR SHALL MAKE ALL REQUIRED ARRANGEMENTS FOR DELIVERY OF EQUIPMENTAND/OR MATERIALS. IT SHALL BE THE RESPONSIBILITY OF EACH CONTRACTOR TO CHECK THE RULES
AND REGULATIONS GOVERNING WORK ON THE PREMISES, INCLUDING THE FOLLOWING:
1.14 ALL SUB CONTRACTORS SHALL CONTACT THE CONTRACTOR TO DETERMINE THE RULES OF THEBUILDING OWNER FOR CONSTRUCTION, TO DETERMINE WHEN AND HOW DELIVERIES CAN BE MADE
(SEE BELOW), WHAT PHASES OF CONSTRUCTION CAN BE DONE ON REGULAR OR OVERTIME, AND INGENERAL, ANY SPECIAL BUILDING REQUIREMENTS WHICH WILL AFFECT THEIR WORK. (IF OVERTIME
WORK IS REQUIRED BY ANY TRADE, APPROVAL MUST BE OBTAINED PRIOR TO THE EXECUTION OF ANYWORK, INCLUDING COST.) THE GENERAL INTENT IS THAT ALL CONSTRUCTION WORK SHALL BE DONE
ON REGULAR TIME.
1.13 EACH CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB SITE AS IT
RELATES TO THEIR WORK.
1.12 THE SUBMISSION OF A PROPOSAL SHALL BE CONSTRUED AS EVIDENCE THAT SUCH AN EXAMINATION
HAS BEEN MADE AND LATER CLAIMS FOR LABOR, EQUIPMENT, OR MATERIAL REQUIRED FORDIFFICULTIES ENCOUNTERED, WHICH COULD HAVE BEEN FORESEEN HAD SUCH AN EXAMINATION BEEN
MADE, WILL NOT BE RECOGNIZED.
1.11 BEFORE SUBMITTING A PROPOSAL, ALL CONTRACTORS SHALL VISIT THE PREMISES, FAMILIARIZE
THEMSELVES WITH EXISTING CONDITIONS AND SATISFY THEMSELVES AS TO THE NATURE AND SCOPE OFTHE WORK AND THE DIFFICULTIES THAT ATTEND ITS EXECUTION.
1.10 THE GENERAL CONTRACTOR SHALL NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES OROMISSIONS BETWEEN THE DRAWINGS, THESE NOTES, AND FIELD CONDITIONS BEFORE COMMENCING
ANY WORK AND REQUEST CLARIFICATION.
1.9 THE GENERAL CONTRACTOR SHALL NOTIFY OWNER'S REP. IMMEDIATELY IF HE CANNOT COMPLY WITHALL WORK CALLED FOR ON THESE DRAWINGS.
1.8 THE GENERAL CONTRACTOR IS WHOLLY RESPONSIBLE FOR THE COORDINATION AND SCHEDULING OF
THE WORK EFFORT FOR ALL SUB-CONTRACTORS, CRAFTSMEN AND TRADESMEN REQUIRED TOCOMPLETE THE JOB.
1.7 OMITTED
1.6 OMITTED
1.5 THE CONTRACTOR SHALL BE FULLY AND SOLELY RESPONSIBLE FOR THE REMOVAL REPLACEMENT AND
RECTIFICATION OF ALL DAMAGED AND DEFECTIVE MATERIAL AND WORKMANSHIP IN CONNECTIONWITH THE CONTRACT WORK. HE SHALL REPLACE OR REPAIR AS DIRECTED ALL SUCH DAMAGED OR
DEFECTIVE MATERIALS WHICH SHALL APPEAR WITHIN A PERIOD OF ONE YEAR FROM THE DATE OFSUBSTANTIAL COMPLETION.
1.4 WHERE THE CONTRACT, NOTES OR DRAWINGS CALL FOR ANY WORK OF A MORE STRINGENT NATURETHAN THAT REQUIRED BY THE BUILDING CODE OR ANY OTHER DEPARTMENT HAVING JURISDICTION
OVER THE WORK, THE WORK OF THE MORE STRINGENT NATURE CALLED FOR BY THE CONTRACT,CONSTRUCTION NOTES OR DRAWINGS SHALL BE FURNISHED IN ALL CASES.
1.3 ALL WORK PERFORMED BY THE CONTRACTOR/SUB-CONTRACTOR SHALL CONFORM TO THE
REQUIREMENTS OF MUNICIPAL, LOCAL OR FEDERAL AND STATE LAWS, AS WELL AS ANY OTHERGOVERNING REQUIREMENTS, WHETHER OR NOT SPECIFIED ON THE DRAWINGS.
1.2 PRIOR TO BEGINNING ANY WORK, THE GENERAL CONTRACTOR SHALL FURNISH A CONSTRUCTION
SCHEDULE SHOWING THE CHRONOLOGICAL PHASES OF HIS WORK, AND ALL RELATED WORK FOR THECOMPLETION OF THE PROJECT. THIS SCHEDULE SHALL INDICATE ALL ORDERING LEAD TIMES, LENGTH
OF TIME FOR EACH PHASE, ITS START AND COMPLETION, WITH A PROJECTED COMPLETION DATE.
1.1 THE GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION, STANDARD FORM OF THEAMERICAN INSTITUTE OF ARCHITECTS, CURRENT EDITION, SHALL APPLY TO ALL WORK IN THIS
CONTRACT, EXCEPT AS SPECIFICALLY MODIFIED BELOW AND/OR BY AGREEMENT.
WALLS SHOWN ALGINED SHALL BE FLUSH AND SMOOTH WITH ADJACENT ALIGNMENTUNLESS NOTED OTHERWISE.
5.7 PROVIDE BLOCKING AT SHOWER AND WATER CLOSETS FOR FUTURE GRAB BARS
5.8 OMITTED
2.6 OMITTED
2.7 OMITTED
5.1 OMITTED
5.11 OMITTED
5.12 OMITTED
7.7 OMITTED
4.13 ALL DRYWALL SHALL BE FINISHED TO A LEVEL 5 STANDARD.
7.10 PROVIDE A COMPLETE AND FULLY OPERATIONAL HEATING INSTALLATION AS REQUIREDBY THE PROJECT SCOPE OF WORK, BY APPLICABLE CODES AND THE CITY OF NEWPORT
BUILDING DEPARTMENT. THE SUBCONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL
AGENCY APPROVALS REQUIRED PRIOR TO THE COMMENCEMENT OF WORK.
7.11 THESE ARE DESIGN DRAWINGS. THEY ARE INTENDED TO IMPLY A DIAGRAMMATIC SCOPE
OF WORK FOR USE BY THE APPROPRIATE SUBCONTRACTOR IN DEVELOPING A BID AND
INSTALLATION. POSITION OF GRILLES, VENTS, CONTROLS AND OTHER ARCHITECTURALAND VISIBLE FEATURES ARE FIXED AS SHOWN UNLESS A CHANGE IN POSITION ISAUTHORIZED BY THE OWNER. THE SUBCONTRACTOR IS RESPONSIBLE FOR POSITIONINGAND ROUTING OF ALL DUCTS, VENTS AND PROVISION OF ANY OTHER NON-VISIBLECOMPONENTS FOR A FULLY OPERATIONAL, SAFE AND CODE COMPLIANT SYSTEM. IFDEVIATION OF VENTS/GRILLES IS REQUIRED BRING TO THE ATTENTION OF THE ARCHITECTPRIOR TO INSTALLATION.
7.12 HVAC AND HOT WATER SYSTEM PIPE INSULATION SHALL COMPLY WITH T24-2-5312 AND
TABLE 2-53E OF THE ENERGY EFFICIENCY STANDARDS. SWITCHES AND OUTLETS TO
ALIGN.
7.13 AIR HANDLING DUCT SYSTEM SHALL BE CONSTRUCTED, INSTALLED, SEALED AND
INSULATED AS SPECIFIED IN CHAPTER 10 OF THE STATE MECHANICAL CODE (TITLE 24,PART 4) T24-2-5316.
7.14 ALL HVAC DUCTWORK SHALL BE RUN WITHIN DESIGNATED CHASES AND WITHIN
ENCLOSED ATTIC SPACES AT THE FIRST AND SECOND FLOOR CEILINGS.
7.15 MECHANICAL SYSTEM TO CONFORM TO THE 2013 CMC.
7.16 MECHANICAL SUB-CONTRACTOR TO SIZE AND SELECT FAU BASED UPON HEATING LOAD
SUMMARY IN THE TITLE 24 REPORT. FAU SHALL HAVE A MIN. EFFICIENCY OF 0.750 AFUE
AND SHALL BE SIZED TO ACCOMMODATE OTHER RELEVANT DESIGN FACTORS SUCH AS
AIR FLOW REQUIREMENTS, OUTDOOR DESIGN TEMPERATURES, COIL SIZING, AVAILABILITYOF EQUIPMENT, OVER SIZING SAFETY MARGIN, ETC. FAU SHALL BE LISTED FORINSTALLATION IN ATTIC OR IN FURRED SPACE LESS THAN 5 FT. IN HEIGHT.
7.17 DUCTS PIERCING WALL BETWEEN HOUSE LIVING AREA AND GARAGE SHALL BE 26 GA.G.I. MATERIAL IN THE GARAGE SEALED AT EDGES, AND NO OPENINGS INTO GARAGE.
7.18 MECHANICAL VENTILATION SYSTEMS FOR TOILET COMPARTMENTS, BATHROOMS,
LAUNDRY ROOMS AND SIMILAR ROOMS SHALL BE CAPABLE OF PROVIDING (5) AIR
CHANGES PER HOUR DIRECTLY TO THE OUTSIDE.ALL HVAC EQUIPMENT SHALL BE LISTED
BY AN APPROVED TESTING AGENCY AND BE INSTALLED IN ACCORDANCE WITH THAT
LISTING.
7.19 APPLIANCES LOCATED IN A GARAGE WHICH GENERATE A GLOW, SPARK OR FLAMESHALL BE INSTALLED WITH PILOTS, BURNERS OR HEATING ELEMENTS AT LEAST 18" ABOVETHE FLOOR.
7.20 ATTIC FURNACES AND COOLING EQUIPMENT SHALL COMPLY WITH THE FOLLOWING:
7.21 PROVIDE ATTIC ACCESS 22"X30" MIN. W/ 30" MIN. CLEAR HEAD ROOM.
7.22 HAVE A CONTINUOUS 24" WIDE SOLID FLOOR ACCESS PATH THERETO
7.23 HAVE 30" DEEP WORKING PLATFORM AT CONTROL SIDE(S)
7.24 HAVE AN ELECTRIC OUTLET AND A LIGHT FIXTURE (CONTROLED BY SWITCH AT THE
ACCESS POINT) AT THE FURNACE.
7.25 PROVIDE HEPA FILTERS ON EACH FAU.
7.26 HEAT REGISTER TO BE LOCATED AS LOW AS POSSIBLE IN WALLS. LOCATE IN TOE KICKS ATKITCHEN, BATHROOMS AND WHERE FEASIBLE. FINAL LOCATIONS AND REGISTER TYPESTO BE APPROVED BY ARCHITECT PRIOR TO COMMENCEMENT OF CONSTRUCTION.
7.27 CUSTOM METAL HOODS SHALL BE APPROVED BY THE MECHANICAL UNIT MANUF. SUBMITSHOP DRAWINGS.
6.28 PROVIDE A COMPLETE AND FULLY OPERATIONAL ELECTRICAL INSTALLATION AS
REQUIRED BY ALL APPLICABLE CODES AND THE CITY OF NEWPORT BEACH BUILDINGDEPARTMENT. THE SUBCONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL AGENCY
APPROVALS REQUIRED PRIOR TO THE COMMENCEMENT OF WORK.
6.29 THESE ARE DESIGN DRAWINGS. THEY ARE INTENDED TO IMPLY A DIAGRAMMATIC SCOPEOF WORK FOR USE BY THE APPROPRIATE SUBCONTRACTOR IN DEVELOPING A BID AND
INSTALLATION. POSITION OF FIXTURES, OUTLETS, SWITCHES AND OTHER ARCHITECTURAL
AND VISIBLE FEATURES ARE FIXED AS SHOWN WITHIN THE ARCHITECTURAL DRAWINGSUNLESS A CHANGE IN POSITION IS AUTHORIZED BY THE OWNER. THE SUBCONTRACTOR IS
RESPONSIBLE FOR ROUTING OF ALL CONDUIT AND POSITION OF ANY OTHER
NON-VISIBLE COMPONENTS FOR A FULLY OPERATIONAL, SAFE AND CODE COMPLIANTSYSTEM.
6.30 ALL ELECTRICAL OUTLETS TO BE CENTERED WITHIN THE BASE, MOUNTED AT 1'-0" A.F.F.
WHERE NO BASE IS, AND ALL SWITCHES AT 3'-6" A.F.F. UNLESS OTHERWISE NOTED.
6.31 ALL CONDUITS TO BE CONCEALED AT ALL WALLS AND SURFACES EXCEPT AS OTHERWISENOTED.
6.32 ALL OUTLETS, SWITCHES, THERMOSTATS, ETC. TO BE CENTERED AND ALIGNED WITH EACH
OTHER BOTH HORIZONTALLY AND VERTICALLY.
6.33 40 LUMENS/WATT OR GREATER FOR GENERAL LIGHTING IN KITCHENS AND ROOMS WITH
WATER CLOSETS; AND RECESSED CEILING FIXTURES ARE IC (INSULATION COVER)
APPROVED.
6.34 ALL COVER PLATES TO BE SCREWLESS TYPE.
General Conditions1
General Conditions and Specifications
DATE ISSUE/REVISION REVIEW
DRAWING DESCRIPTION
PROJECT
All drawings and written material appearingherein constitute original and unpublishedwork of the architect and may not beduplicated, used or disclosed without thewritten consent of Laidlaw Schultz Architects.
3111 Second AvenueCorona del Mar, CA 92625-2322(949) 645-9982 Fax: (949) 645-9554www.LSarchitects.com
SHEET NO.
12.5 TILE SHALL BE LAID IN SQUARE PATTERN WITH COURSES PARALLEL TO WALLS,
OF THE AREA BEING WORKED IN, AND THE AUTHORIZATION UNDER WHICH THE BEING PERFORMED, MATERIALS BEING USED, THE CONSTRUCTION SPACE NUMBER BY OWNER'S REP., AND SHOULD INCLUDE A COMPLETE DESCRIPTION OF THE WORK16.2 ALL CLAIMS FOR ADDITIONAL WORK WILL BE SUBMITTED IN WRITING FOR REVIEW
CLAIMS SHALL BE VALID UNLESS SO MADE. UNLESS OTHERWISE AGREED, NO SHALL THAN BE AS PROVIDED FOR IN THE "CHANGES IN THE WORK". NO SUCH ANY EVENT BEFORE PROCEEDING TO EXECUTE THE WORK AND THE PROCEDURE THEREOF WITHIN A REASONABLE TIME AFTER RECEIPT OF SUCH INSTRUCTIONS, IN EXTRA COST UNDER THIS CONTRACT, HE SHALL GIVE OWNER'S REP. WRITTEN NOTICE16.1 IF THE GENERAL CONTRACTOR CLAIMS THAT ANY REVISION TO DRAWINGS INVOLVE
RESPONSIBLE FOR ALL UNLOADING, CHECKING, AND STORING OF SAME IN ALL HIS MATERIAL OR EQUIPMENT TO THE POINT OF USE, AND SHALL BE15.1 THE GENERAL CONTRACTOR AGREES TO PAY ALL TRANSPORTATION CHARGES ON
FRAMES, ETC., TO THE SATISFACTION OF THE OWNER'S REPRESENTATIVE PRIOR TO BASE, ALL WALLCOVERING INSTALLATIONS, ALL MAIL CHUTES, ALL DOORS AND14.2 THE GENERAL CONTRACTOR SHALL THOROUGHLY CLEAN COVE BASE AND STRAIGHT
TO THE SATISFACTION OF ARCHITECT AND OWNER PRIOR TO BEING TURNED OVER THROUGHOUT THE PERIOD OF CONSTRUCTION SHALL BE THOROUGHLY CLEANED THE GENERAL CONTRACTOR IN ADDITION TO BEING AMPLY PROTECTED14.1 THE "EXISTING TO REMAIN", EXISTING RELOCATED OR NEW ITEMS INSTALLED BY
ANY CLAIM FOR EXTENSIONS OF TIME CAUSED THEREBY SHALL BE ADJUSTED AT EXECUTED UNDER THE CONDITIONS OF THE ORIGINAL CONTRACT, EXCEPT THAT THE CONTRACT SUM BEING ADJUSTED ACCORDINGLY. ALL SUCH WORK SHALL BE OR MAKE CHANGES BY ALTERING, ADDING TO OR DEDUCTING FROM THE WORK,13.1 THE OWNER WITHOUT INVALIDATING THE CONTRACT, MAY ORDER EXTRA WORK
FLUSH INSTALLATION OF ALL VARYING FLOOR MATERIALS USED. ALL TRANSITION12.13 CONTRACTOR TO COORDINATE ALL FLOORING CONTRACTORS INVOLVED TO ENSURE
12.12 CARPET CONTRACTOR TO PROVIDE SEAMING DIAGRAM TO ARCHITECT FOR
12.11 STONE, WOOD AND TILE FLOORING CONTRACTORS TO SUBMIT ACTUAL DIMENSIONED
PROTECTION FOR ALL RESILIENT FLOORING WORK FOR THE DURATION OF THE12.10 THE GENERAL CONTRACTOR SHALL PROVIDE AND MAINTAIN ADEQUATE
WHICH IS TO BE THOROUGHLY MACHINE BUFFED AND LEFT IN CONDITION ENTIRELY RESILIENT TILE FLOOR TWO (2) APPLICATIONS OF AN APPROVED NON-SLIP WAX12.9 WHEN DIRECTED, AFTER CLEANING, THE GENERAL CONTRACTOR SHALL GIVE
CARTONS AND CONTAINERS SHALL BE REMOVED FROM THE BUILDING. REMOVING ALL SPOTS OF ADHESIVE AND SURFACE STAINS AND ALL SCRAPS.12.8 UPON COMPLETION, ALL WORK SHALL BE CLEANED BY THE CONTRACTOR,
THE LAYING OF FLOORING. STONE FLOORS SHALL BE COVERED AFTER12.6 SPACES BEING SURFACED SHALL BE CLOSED TO TRAFFIC AND OTHER WORK DURING
PERMIT THE ADHESIVE TO REACH ITS INITIAL SET BUT NOT ITS FINAL SET. CEMENTING TILE SHALL BE APPLIED FAR ENOUGH IN ADVANCE OF THE SETTING TO CEMENTED AND SHALL BE LAID WITH TIGHT JOINTS. THE ADHESIVE USED FOR UNLESS OTHERWISE INDICATED ON DRAWINGS. THE TILE SHALL BE SECURELY
BEING TURNED OVER TO THE OWNER
PROPERLY TESTED AND/OR TAGGED. THE NUMBER OF MASTER AND PASS KEYS BUILDING REQUIREMENTS. CODES AND/OR KEYS ARE TO BE DELIVERED TO OWNER10.3 ALL LOCK SETS SHALL BE CODED AND/OR KEYED IN ACCORDANCE WITH THE
10.2 THE GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL DOORS AS SPECIFIED ON
ASSEMBLIES AS SHOWN ON THE DRAWINGS UNLESS OTHERWISE NOTED.10.1 THE GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL REQUIRED BUCKS
THE DRAWINGS UNLESS OTHERWISE NOTED.
WORK IS BEING PERFORMED.
PAYMENT ON SUCH BILLS WILL NOT BE MADE UNTIL FINAL SETTLEMENT.
CONNECTION WITH THE CONTRACT.
THE TIME OF ORDERING SUCH CHANGE.
METHODS TO BE APPROVED BY THE OWNER'S REPRESENTATIVE.
APPROVAL PRIOR TO INSTALLATION.
TO THE OWNER.
SATISFACTORY TO ARCHITECT.
PLAN FOR APPROVAL PRIOR TO INSTALLATION.
CONTRACT, AND REMOVE ALL PROTECTION PRIOR TO PUNCH LIST.
INSTALLATION FOR PROTECTION.
FASCIAS, JAMBS, BUCKS, REVEALS, RETURNS, AND ALL VERTICAL SURFACES NOT11.2 WALLS SHALL INCLUDE SURFACES FROM FLOOR TO CEILING, INCLUDING PILASTERS,
11.1 UNLESS OTHERWISE SPECIFIED, ALL AREAS ARE TO BE PAINTED IN ACCORDANCE
FOR REVIEW, AND FABRICATION OF MATERIAL SHALL NOT BE COMMENCED UNTIL10.4 DETAILED DOOR AND HARDWARE SCHEDULES SHALL BE SUBMITTED TO ARCHITECT
SHALL BE COORDINATED WITH THE OWNER AND THE OWNER'S REP.
12.3 ALL NEW FLOORING IS TO BE INSTALLED BY GENERAL CONTRACTOR AND SHALL BE
DONE AND RECEIVE ARCHITECT'S REVIEW PRIOR TO INSTALLATION OF FIN. FLOORING.12.2 THE GENERAL CONTRACTOR SHALL NOTIFY OWNER'S REP. AFTER FLOOR PATCHING IS
CONTINUOUS SMOOTH FLOOR SURFACE. LEVEL NOT TO EXCEED 1/4" IN 10'-0" IMPERFECTION (PROJECTIONS SHALL BE REMOVED AND PATCHED) TO PROVIDE A12.1 THE GENERAL CONTRACTOR SHALL FLASH PATCH ALL CRACKS, HOLES OR OTHER
ATTENTION OF THE OWNER'S REP. AND FINISHED PER ARCHITECT'S INSTRUCTIONS. FINISH NOTED OR ARE NOTED TO REMAIN UNFINISHED SHALL BE BROUGHT TO THE SPECIFICALLY NOTED OTHERWISE. ANY SURFACES WHICH DO NOT HAVE A SPECIFIC FINISHES AS INDICATED ON THE DRAWINGS IN THE SPECIFICATIONS UNLESS11.12 IT IS THE INTENT OF THE DRAWINGS THAT ALL EXPOSED SURFACES RECEIVE
FLOORING, ETC.) AND INDICATE ALL NECESSARY "TOUCH-UP" PAINTING AND/OR COMPLETION OF WORK BY ALL TRADES (INCLUDING TELEPHONE INSTALLATION,11.11 THE CONTRACTOR SHALL EXAMINE ALL AREAS OF CONSTRUCTION AFTER
AWAY AND SURFACES PLASTER-PATCHED OR SPACKLED TO INSURE A PERFECTLY11.10 ALL EXISTING UNEVENNESS IN ALL PARTITIONS SHALL BE SANDED OR CHIPPED
11.9 ALL EXISTING LOOSE PAINT SHALL BE REMOVED AND SPACKLED OR PLASTER
SQUARE. ALL WORKMANSHIP WHICH IS NOT JUDGED TO BE FIRST QUALITY BY WALLCOVERING ADJOINING WOOD OR METAL TRIM SHALL BE CUT STRAIGHT AND EDGES, ALL PASTE AND BRUSH MARKS SHALL BE THOROUGHLY REMOVED. WALLCOVERINGS SHALL BE SMOOTH, WITH NO WRINKLES, BUBBLES OR LOOSE
RECEIVE ONE (1) PRIME COAT AND TWO (2) FINISH COATS OF PAINT IN COLOR SELECTED BY ARCHITECT. HE SHALL PROPERLY PREPARE ALL SURFACES TO11.7 THE CONTRACTOR SHALL USE THE SPECIFIED BASE PAINT IN COLORS AND FINISHES
INCLUDING BUT NOT LIMITED TO LIGHT FIXTURES, DIFFUSERS, REGISTERS AND SLAB PAINT FROM WHERE IT HAS SPILLED, SPLASHED OR SPLATTERED ON SURFACES, REPLACING SAME WHEN PAINTING HAS BEEN COMPLETED. HE SHALL REMOVE ALL PLATES, SURFACE HARDWARE, ETC., PRIOR TO PAINTING, PROTECTING AND11.6 THE CONTRACTOR SHALL REMOVE ALL ELECTRICAL SWITCH PLATES AND OUTLET
TWO FULL COATS OF SPECIFIED PAINT FREE OF BRUSH MARKS, U.O.N.11.5 ALL WOOD SHELVING AND PAINTED DOORS SHALL RECEIVE PRIMING,SANDING AND
ETC., TO PROVIDE A PERFECTLY SMOOTH FINISH AND SURFACE READY FOR PRIME11.4 ALL WALLS AND CEILINGS SHALL BE PROPERLY PREPARED, SPACKLED, SANDED,
SHALL SUBMIT 3 SAMPLES (12" X 12") FOR REVIEW BY THE OWNER'S REP.11.3 PAINT COLORS SHALL BE SPECIFIED BY ARCHITECT AND THE GENERAL CONTRACTOR
AND IF LAID,SHALL BE REMOVED AND REPLACED WITH ACCEPTABLE TILE. COORDINATES. TILE HAVING CHIPPED OR ROUNDED CORNERS WILL BE REJECTED IMPERFECTIONS. SEAMS SHALL BE KEPT IN ACCURATE ALIGNMENT ALONG BOTH COMPLETE, IT SHALL BE FREE FROM BUCKLES, BUBBLES, OPEN JOINTS OR OTHER12.4 ALL WORKMANSHIP SHALL BE OF THE BEST QUALITY AND WHEN THE WORK IS
AS SPECIFIED ON CONSTRUCTION DOCUMENTS.
NONCUMULATIVE.
PATCHING.
SELECTED BY ARCHITECT.
THE OWNER'S REPRESENTATIVE WILL NOT BE ACCEPTED.
MANUFACTURER INSTALL SPECIFICATIONS, WHERE DESIGNATED. ALL11.8 THE GENERAL CONTRACTOR SHALL INSTALL WALLCOVERINGS AS PER
EVEN SURFACE.
PATCHED.
FITTINGS, ETC.
INCLUDED IN CEILING.
SUCH REVIEW HAS BEEN RETURNED.
AND PAINT. LEVEL 5 FINISH AT ALL EXPOSED GYSPUM BOARD
WITH FINISH PLANS.
OMITTED12.7
TILED INSTALLATIONS SHALL MEET MNFTS. REQ., AND PER ANSI STANDARDS, TILE
COUNCIL OF AMERICA (TCA) HANDBOOK for CERAMIC TILE INSTALLATION,
AMERICAN STANDARDS NATIONAL INSTITUTE (ANSI), NATIONAL TILE CONTRACTORS
INSTALLATION (NTCA) MANUAL, MARBLE INSTITUTE OF AMERICA DESIGN MANUAL,
AND PER CODE REQUIREMENTS.
12.14
EXPANSION JOINTS:EXTERIOR - FOR TEMPERATURE CHANGES UP TO 100 DEGREES f: LOCATE MOVEMENT
JOINTS IN EXTERIOR TILE WORK ON WALLS AND FLOOR NOT MORE THAN 16' ON
CENTER BASED ON A 12" WIDE MOVEMENT JOINT. FOR TEMPERATURE CHANGES
GREATER THAN 100 DEGREES F ADD 116" FOR EVERY 15 DEGREES f INCREMENT.
MOVEMENT JOINTS ARE ALSO REQUIRED OVER ALL CONSTRUCTION, CONTROL, OR
EXPANSION JOINTS IN THE BACKING AND WHERE BACKING MATERIALS CHANGE ORCHANGE DIRECTIONS, INCLUDING TERMINATIONS OF TILE WORK WHERE IT WOULD
ABUT RESTRAINING OR DISSIMILAR SURFACES.
INTERIOR: FOR ENVIRONMENTALLY CONTROLLED INTERIORS NOT SUBJECTED TOTEMPERATURE VARIATIONS GREATER THAN 20 DEGREES F OR EXPOSED TO MOISTURE,
PLACE FIELD MOVEMENT JOINTS TWICE THE DISTANCE AS REQUIRED FOR EXTERIORS
(24'-32' ON CENTER) AND AT ALL OTHER LOCATIONS AS REQUIRED PER PRIOR
PARAGRAPH.
AREAS EXPOSED TO DIRECT SUNLIGHT SHALL HAVE EXPANSION JOINTS SPACE AT 8'TO 12' ON CENTER
ALL STONE PAVING SYSTEMS SHALL INCLUDE ADEQUATE MOVEMENT JOINTS. REFER
TO ANSI A108.1 AND TCNA 3J171 FOR MOVEMENT JOINTS LOCATIONS AND DESIGN.
MEMBRANES FOR STONE AND TILE WALKING SURFACES
CLEAVAGE MEMBRANES: USED IN THICK BED INSTALLATIONS BELOW THEREINFORCED MORTAR BED TO INTESTINALLY PREVENT THE BOND BETWEEN THE STONE
SETTING SYSTEM AND THE SUBSTRATE SLAB, ALLOWING INDEPENDENT MOVEMENT
(FREE-FLOATING) OF THE STONE SETTING SYSTEM. CLEAVAGE MEMBRANES CAN BEEITHER SHEET APPLIED OR LIQUID APPLIED
CRACK ISOLATION MEMBRANES: USED TO ISOLATE THE STONE FROM MINOR IN-PLANE
CRACKING OF THE SUBSTRATE SURFACE IN THIN-SET APPLICATIONS. CRACKISOLATION MEMBRANES CAN BE SHEET APPLIED, TROWEL APPLIED OR LIQUID APPLIED
AND MUST MEET ANSI A111.12.
12.15
12.16
TECHNICAL DATA:
EACH STONE VARIETY USED FOR EXTERIOR STONE PAVING SHOULD CONFORM TO
THE APPLICABLE ASTM STANDARD SPECIFICATION AND THE PHYSICAL REQUIREMENTSCONTAINED THEREIN. THE SPECIFICATION FOR EACH STONE TYPE.
12.17
8.4 ALL EXISTING PLUMBING BEING ABANDONED SHALL BE CAPPED BEHIND EXISTING
9.12 WHERE FILES ARE SHOWN AS BEING SET INTO CABINETWORK, THE CABINET
AND SUBMITTALS SHALL NOT BE WAIVED UNLESS WRITTEN PERMISSION TO DO SO SUBMITTAL AND SHOP DRAWINGS PREPARATION ARE REVIEWED. SHOP DRAWINGS9.15 ALL MILLWORK, SPECIAL PRODUCTS, AND SPECIAL ASSEMBLIES ARE SUBJECT TO
9.14 COORDINATION OF MILLWORK, STONE, OR OTHER SPECIALTIES CONTRACTORS IS
DRAWINGS. OWNER'S REP. WILL NOT REVIEW DRAWINGS WHICH ARE INCOMPLETE, DIMENSIONS CRITICAL OR OTHERWISE, ARE TO BE CALLED OUT ON THE SHOP ALL JOINTS, CORNERS, EDGES ARE TO BE DETAILED IN INDIVIDUAL DETAILS. ALL9.13 ALL MILLWORK SHOP DRAWINGS ARE TO CALL OUT ALL MATERIALS AND FINISHES.
IS GIVEN BY ARCHITECT.
THE RESPONSIBILITY OF THE GENERAL CONTRACTOR.
AND/OR SHOW MINIMAL DETAILING AND INFORMATION.
CONTRACTOR SHALL SET AND BOLT ALL FILES TOGETHER.
8.7 BEFORE BEING COVERED UP OR BUILT-IN, PIPING SHALL BE TESTED AS REQUIRED BY
BE CUT OFF FOR REPAIR WITHOUT INTERFERENCE OR INTERRUPTION OF THE UNDER THIS SECTION SO THAT ANY FIXTURE, LINE, OR PIECE OF APPARATUS MAY FOR THE PROPER CONTROL OF THE VARIOUS APPARATUS AND PIPELINES INSTALLED8.6 FURNISH ALL VALVES AS INDICATED ON THE DRAWINGS OR AS MAY BE REQUIRED
8.5 THE PLUMBING CONTRACTOR'S WORK SHALL BE COORDINATED WITH ALL OF THE
CEILING PLENUM OF FLOOR BELOW TO COMPLETE WORK ON FLOOR BEING CEILING REMOVAL AND REINSTALLATION REQUIRED FOR PLUMBING WORK IN SHALL ALSO INCLUDE IN HIS ESTIMATE AN ALTERNATE PRICE FOR WORK FOR SURROUNDING SURFACES IN MATERIAL AND FINISH. THE GENERAL CONTRACTOR FINISHED SURFACES. EXISTING SURFACES SHALL BE PATCHED TO MATCH EXISTING
MEET CURRENT AWI STANDARDS. REFERENCE SPECS. FOR ALL APPLICABLE
9.11 ALL THE WORK SHALL BE FABRICATED, ASSEMBLED, FINISHED AND ERECTED TO
IN THE SHOP AND DELIVERED TO THE BUILDING READY TO ERECT IN PLACE.9.10 ALL FINISHED WORK SHALL, AS FAR AS PRACTICAL, BE ASSEMBLED AND FINISHED
9.9 WHERE MEMBERS ARE MITERED OR BUTTED, THEY SHALL BE JOINED AND SECURED
9.8 THE CABINET CONTRACTOR SHALL PROVIDE RUBBER BUMPERS ON ALL WOOD
9.7 THE CABINET CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND
9.6 THE CABINET CONTRACTOR SHALL SUBMIT SHOP DRAWINGS AND SAMPLES TO
CONTRACTOR TO CHECK JOB PROGRESS AND COORDINATE WITH OTHER TRADES9.5 ALL "INSTALLED" CABINETS SHALL BE SCRIBED TO WALL OR CEILING. CABINET
9.4 ALL CABINET FINISHES SHALL BE AS NOTED ON DETAIL DRAWINGS CONCERNED.
9.3 ALL "INSTALLED" CABINETRY SHALL COMPLY WITH LOCAL BUILDING CODES AND WIC STDS.
9.2 THE GENERAL CONTRACTOR SHALL CLOSELY COORDINATE HIS WORK WITH THAT
9.1 REFERENCE SPECIFICATIONS FOR MILLWORK FINISH AND MATERIAL QUALITY. MILLWORK
THE OWNER'S REPRESENTATIVE.
CONDITIONS AT JOB SITE.
IN A MANNER TO ENSURE AGAINST THE JOINT OPENING.
REQUIREMENTS.
DOORS.
INVOLVED. NO FILLER PANELS ALLOWED.
THE AUTHORITIES HAVING JURISDICTION.
SERVICE TO THE REST OF THE BUILDING.
OF THE CABINET CONTRACTOR.
OTHER TRADES.
RENOVATED.
FITTINGS, AND ACCESSORIES TO THE OWNER'S REPRESENTATIVE FOR REVIEW.8.2 THE PLUMBING CONTRACTOR SHALL SUBMIT CATALOG CUTS OF ALL NEW FIXTURES,
ALL PLUMBING ROUGHINS, FIXTURES AND ACCESSORIES SHOWN ON ALL8.1 THE GENERAL CONTRACTOR'S PLUMBING CONTRACTOR SHALL SUPPLY AND INSTALL
MANUFACTURER'S SPECIFICATIONS.8.3 THE PLUMBING CONTRACTOR'S WORK SHALL BE COORDINATED WITH
CONSTRUCTION PLANS AND DETAIL DRAWINGS.
TO MEET AWI PREMIUM STANDARD.
8.8 PROVIDE A COMPLETE AND FULLY OPERATIONAL PLUMBING AND SEWAGEINSTALLATION AS REQUIRED BY ALL APPLICABLE CODES AND THE CITY OF NEWPORTBUILDING DEPARTMENT. THE SUBCONTRACTOR IS RESPONSIBLE FOR OBTAINING ALLAGENCY APPROVALS REQUIRED PRIOR TO THE COMMENCEMENT OF WORK.
8.9 THESE ARE DESIGN DRAWINGS. THEY ARE INTENDED TO IMPLY A DIAGRAMMATIC SCOPEOF WORK FOR USE BY THE APPROPRIATE SUBCONTRACTOR IN DEVELOPING A BID ANDINSTALLATION. POSITION OF FIXTURES, TRIM, FITTINGS AND OTHER ARCHITECTURAL AND
VISIBLE FEATURES ARE FIXED AS SHOWN UNLESS A CHANGE IN POSITION IS AUTHORIZED
BY THE OWNER. THE SUBCONTRACTOR IS RESPONSIBLE FOR ANY UPGRADING OR
MODIFICATIONS TO THE EXISTING PLUMBING OR SEWAGE SYSTEMS, FOR ROUTING OF
ALL PIPES AND VENTS, AND POSITION OF ANY OTHER NON-VISIBLE COMPONENTS FOR AFULLY OPERATIONAL, SAFE AND CODE COMPLIANT SYSTEM.
8.10 ALL PLUMBING FIXTURES AND FITTINGS SHALL BE CERTIFIED BY THE CALIFORNIA ENERGYCOMMISSION.
8.11 ALL FIXTURES AND TRIM SHALL CONFORM TO THE REQUIREMENTS OF TITLE 24.
8.12 WATER HEATERS WHICH DEPEND ON THE COMBUSTION OF FUEL FOR HEAT SHALL NOT BEINSTALLED IN ANY ROOM USED OR DESIGNED TO BE USED FOR SLEEPING PURPOSES,BATHROOM, CLOTHES CLOSET OR OTHER CONFINED SPACE OPENING INTO ANY
BATHROOM OR BEDROOM. EXCEPTION: DIRECT VENT WATER HEATERS.
8.13 WATER HEATER IN GARAGE IS TO BE ELEVATED TO A POINT WHERE THE PILOT, BURNER
AND SWITCHES ARE LOCATED A MINIMUM OF 18" ABOVE THE FLOOR.
8.14PROVIDE SEISMIC ANCHORAGE FOR THE WATER HEATER.
8.15PROVIDE A PRESSURE AND TEMPERATURE RELIEF VALVE W/ DRAIN TO OUTSIDE FOR
WATER HEATERS.
8.16PROVIDE SOFTWATER FOR LAUNDRY ROOM AND DISHWASHER.
8.17 ALL CLEANOUTS TO BE COORDINATED WITH ARCHITECT PRIOR TO CONSTRUCTION.
8.18PROVIDE FLOOR DRAINS ADJACENT TO WATER CLOSETS. DRAINS SHALL BE SQUARE.FINISH TO MATCH HARDWARE. SUBMIT SAMPLE TO ARCHITECT FOR APPROVAL. REFERTO SOILS REPORT FOR ADDITIONAL CUT CONSIDERATIONS.
8.19PROVIDE LINEAR TILE IN DRAIN AT ALL SHOWERS, BY CALIFORNIA FAUCET CERA LINECUSTOM TILE-IN-DRAIN OR APPROVED EQUAL.
8.20 WHERE TRAPS ARE VISIBLE WITHIN THE ROOM, PROVIDE BOTTLE-TRAPS IN FINISH TOMATCH THE HARDWARE.
8.21 ALL CLEANOUTS TO BE LOCATED IN INCONSPICUOUS LOCATIONS. WHERE THIS CAN NOT
BE ACHIEVED, BRING TO THE ATTENTION OF THE ARCHITECT. FINAL PLACEMENT TO BE
COORDINATED WITH SURROUNDING FINISHES.
7.28 COORDINATE ALL EXPOSED VENTS AND LOCATIONS, INCLUDING RETURN AIR SUPPLY,
WITH ARCHITECT PRIOR TO CONSTRUCTION.
7.29 VENTS AND RETURN AIR ARE TO BE EITHER TAPED IN LINEAR GRILLES OR BAR GRILLES BY
ARCHITECTURAL GRILLE A6 SERIES W/ A FRAME INSTALLATION.
7.30 MECHANICAL VENTILATION AT RESTROOMS AND SIMILAR ARE TO USE A REMOTE FAN IN
CONJUNCTION WITH A TAPED IN LINEAR DIFFUSER.
General Conditions1
VAPOR BARRIERCONCRETE SHALL BE TESTED FOR CALCIUM AND WATER INTRUSION AND
PROVIDED WITH A WATERPROOF MEMBRANE AS REQUIRED PER HARDWOOD, TILE,
CARPET MANUFACTURER REQUIREMENTS.
WATER VAPOR EMISSION: WATER VAPOR EMISSION SHOULD NOT EXCEED 8
LBS.PER1000 SQ FEET (OR MORE STRINGENT AS REQUIRED PER INDIVIDUALFLOORING MNFT. REQ.) PER24 HOUR PERIOD AS DETERMINED BY THE #625
ANHYDROUS CALCIUM CHLORIDE TEST AVAILABLE FROM TAYLOR TOOLS, DENVER,
CO 303-371-7667. EQUIVALENT TEST (VAPRECISION ® OR SIN AK'S “DOME”
TEST)ARE ALSO AVAILABLE FROM VARIOUS SUPPLIERS. ANY TEST USED MUST BE
PERFORMED TO COMPLY WITH ASTM F-1869-98.
12.18
General Conditions and Specifications
DATE ISSUE/REVISION REVIEW
DRAWING DESCRIPTION
PROJECT
All drawings and written material appearingherein constitute original and unpublishedwork of the architect and may not beduplicated, used or disclosed without thewritten consent of Laidlaw Schultz Architects.
3111 Second AvenueCorona del Mar, CA 92625-2322(949) 645-9982 Fax: (949) 645-9554www.LSarchitects.com
SHEET NO.
Construction Cost Determination1
Valuation
Skylight Product Listing2
DATE ISSUE/REVISION REVIEW
DRAWING DESCRIPTION
PROJECT
All drawings and written material appearingherein constitute original and unpublishedwork of the architect and may not beduplicated, used or disclosed without thewritten consent of Laidlaw Schultz Architects.
3111 Second AvenueCorona del Mar, CA 92625-2322(949) 645-9982 Fax: (949) 645-9554www.LSarchitects.com
SHEET NO.
1
Valuation
Fireplace Certification
Type/No.Size (wxh)Operation Frame Glazing U-Value SGHC Orientation Notes
Door Schedule4
No.Size (wxh)Type Core Glazing
3'-0" x 6'-0"
KeyNotes
H Wd
U-Value SGHC Orientation Notes
General Notes:
- All exterior doors shall be La Cantina Contemporary Clad Aluminum Cladunless noted otherwise- All exterior windows shall be Kolbe Vistaluxe Aluminum Clad unless noted
otherwise
- Provide shop drawings for approval- All glazing with multiple panes shall be provided with spacers when dualglazed- Contractor to field measure all openings prior to fabricating new doors.
- All exposed hardware to be oil rubbed bronze- Coordinate locksets with owner- All door assemblies to have a U-factor as noted w/ Title 24.
- All wood doors to be 1
34" solidcore U.N.O.- Each pane of safety glazing installed in hazardous locations shall be identified(acid etched, sand blasted, ceramic fired, etc) by a manufacturer's
designation, the manufacturer or installer and the safety glazing standardwhich it complies. Multi-pane assembles shall be identified per CRCR308.1.Fenestration products shall be certified for overall U-values and overall
SHGC, and shall have a temporary label which lists the certified U-value and
SHGC, certifies that applicable air infiltration requirements are met.- Verify door size with actual condition prior to placing order- Verify compliance of specified doors and windows against minimum
requirements specified w/ the Title 24 documentation.- The lad resistance of glass under uniform load shall be determined inaccordance with ASTM E 1300.
- Project is in "VHFHZ" glazing shall be in compliance w/ CBC Chapter 7A
Legend:
Gls -
12" GlassDual - Dual glazed unit
T - Denotes tempered/safety glazing as per
code req. (Lower corner) refer to 1/A.002for additional criteria.
Lam - Laminated glazed unit
Wd - WoodSC - Solid core wood veneerClad - Aluminum clad wood
Alum - AluminumP - Frosted Privacy GlassMtl. - Painted Metal
(E) - Existing
General Notes Legend
NFRC #Location
Readily openable from the inside without key or special knowledge
Window Schedule3
001A
A BInterior Solid CoreWood Door Interior Solid CoreWood Pocket Door
J Exterior Wood SectionalGarage Door
Re
f
e
r
t
o
S
c
h
e
d
u
l
e
Ref. toSchedule
Re
f
e
r
t
o
S
c
h
e
d
u
l
e
Ref. toSchedule
D Frameless Glass
Shower Door
Re
f
e
r
t
o
S
c
h
e
d
u
l
e
Ref. toSched.
A1 Dual / TAwningClad3'-7" x 4'-6"
Casement Window
Kolbe VistaluxeCFixed Window
Direct Set
Kolbe VistaluxeB
Re
f
.
t
o
Sc
h
e
d
u
l
e
Ref. toSchedule
Re
f
.
t
o
Sc
h
e
d
u
l
e
Ref. toSchedule
C
Re
f
e
r
t
o
S
c
h
e
d
u
l
e
Ref. toSchedule
Interior Solid Core2-Panel Pocket Door
0.280.30
G
E
La CantinaContemporaryClad In-Swing Door
H Exterior Stainedwood Gate
F
Bedroom 203
B1 Dual / TClad1'-4" x 4'-7"Fixed Front0.330.30 Bedroom 200
B2 Dual / TCladFixed Front0.330.30
B3 Dual / TCladFixed 0.330.30
B4 Dual / TCladFixed 0.330.30
C1 Dual / TCasement Clad3'-0" x 6'-0"0.280.30 Garage 100
C2 Dual / TCasement Clad 0.280.30
C3 Dual / TCasement Clad 0.280.30
Dual / TCasement Clad 0.280.30
Dual / TCasement Clad 0.280.30
Dual / TCasement Clad 0.280.30
C4
C5
C6
D1
100A
-
SC
-
202
0.31 0.28 BackF Clad Dual / T
---
---
208
Re
f
e
r
t
o
S
c
h
e
d
u
l
e
Ref. toSched.
Re
f
e
r
t
o
S
c
h
e
d
u
l
e
Refer to Schedule
Re
f
e
r
t
o
S
c
h
e
d
u
l
e
Refer to Schedule
La Cantina Contemporary CladSliding Door - 5 equal - OXXXO
La Cantina Contemporary CladSliding Door - 2 equal - XX
T TT
B5 Dual / TCladFixed 0.330.30
B6 Dual / TCladFixed 0.330.30
B7 Dual / TCladFixed 0.330.30
B8 Dual / TCladFixed 0.330.30
B9 Dual / TCladFixed 0.330.30
B10 Dual / TCladFixed 0.330.30
B11 Dual / TCladFixed 0.330.30
Bedroom 203
Front
Right
B12 Dual / TCladFixed 0.330.30
Back
Master Bed 210
Master Bed 210
Right
Right
Right
Re
f
e
r
t
o
S
c
h
e
d
u
l
e
Refer to Schedule
Re
f
e
r
t
o
S
c
h
e
d
u
l
e
Ref. to
Sched.
001B 4'-0" x 9'-3"H Wd ----
-
-
-
100B SC
----
Self-closing, self-latching, tight-fitting, 20 min. rated.
A
100C SC
----
-
A
-A SC -
2'-6" x 8'-0"
104B ---
-
0.31 0.28 RightCladDual / T
104C
-A SC -2'-6" x 8'-0"---
A SC ----
E
-F
G Provide 2-Panel Pocket as required each side. See Plan.0.31 0.28 BackCladDual / T
107A
107B
109
-0.31 0.28 FrontF Clad Dual / T
200A
-
200B
-
-
-
-
A SC -----
A SC -----
C SC ----
4'-6 12 " x 10'-1"
B SC ----
B SC ----
24'-9 12 " x 9'-6"
209A
D Gls T ---1'-8" x 7'-0"-
D2
Dual / TCasement Clad 0.280.30C7
Re
f
e
r
t
o
S
c
h
e
d
u
l
e
Ref. toSchedule
Fixed Window
3-EQ Direct Set Mulled togetherKolbe VistaluxeA
3-
E
q
u
a
l
Awning Window
Kolbe VistaluxeA
Re
f
.
t
o
Sc
h
e
d
u
l
e
Ref. toSchedule
Dual / TClad4'-9" x 13'-3"Fixed Left0.330.30 Stair
Dual / TClad4'-9" x 13'-3"Fixed Left0.330.30 Stair
Second Floor Hall
1'-4" x 4'-7"
1'-4" x 4'-7"
1'-4" x 4'-7"
Bedroom 200
Front
Front Bedroom 203
Right
Second Floor Hall
Right Second Floor Hall
Right Second Floor Hall
Right Second Floor Hall
4'-6 12 " x 6'-7"
4'-6 12 " x 6'-7"
4'-6 12 " x 6'-7"
4'-6 12 " x 6'-7"
4'-6 12 " x 6'-7"
Master Bed 2101'-4" x 4'-7 12 "
1'-4" x 4'-7 12 "
1'-4" x 4'-7 12 "
1'-4" x 4'-7 12 "
1'-4" x 4'-7 12 "
B13
B14
Master Bath 209
Master Bath 209
Back
Back
Dual / TCladFixed 0.330.30 Back
Dual / TCladFixed 0.330.30 Back
Master Bed 210
Master Bed 210
1'-4" x 4'-7 12 "
1'-4" x 4'-7 12 "
B15
B16
Dual / TCladFixed 0.330.30
Dual / TCladFixed 0.330.30
Front
Front
Right
Right
Right
Right
Left
Right
Dual / TCasement Clad 0.280.30
Dual / TCasement Clad 0.280.30
Dual / TCasement Clad 0.280.30
Dual / TCasement Clad 0.280.30
Dual / TCasement Clad 0.280.30
Dual / TCasement Clad 0.280.30
Dual / TCasement Clad 0.280.30
Dual / TCasement Clad 0.280.30
Dual / TCasement Clad 0.280.30
Dual / TCasement Clad 0.280.30
Dual / TCasement Clad 0.280.30
Dual / TCasement Clad 0.280.30
Dual / TCasement Clad 0.280.30
Dual / TCasement Clad 0.280.30
Garage 100
Laundry 103
Powder 102
Foyer 107
Living Room 109
Living Room 109
Back Kitchen 109C8
C9
3'-0" x 6'-0"
3'-0" x 6'-0"
3'-0" x 6'-0"
3'-0" x 6'-0"
3'-0" x 6'-0"
3'-0" x 6'-0"
2'-6" x 6'-0"
2'-6" x 4'-6"Bedroom 203
Bedroom 203Right2'-6" x 4'-6"C10
C11 2'-6" x 4'-6"Right Bath 205
Master Bed 210
Master Bed 210
3'-0" x 4'-6"C12
3'-0" x 4'-6"C13
Right
Right
Left
2'-6" x 4'-6"
2'-6" x 4'-6"
Left
C14
C15
Master Bath 209
Master Bath 209
Left Master Closet 2083'-0" x 4'-6"C16
Left3'-0" x 4'-6"
Left3'-0" x 4'-6"
Left3'-0" x 4'-6"
Study/Gym 207C17
C18
C19
Study/Gym 207
Study/Gym 207
2'-6" x 4'-6"
3'-0" x 4'-6"
Left
Left
C20
C21
Bath 201
Bedroom 200
Readily openable from the inside without key or special knowledge
J17'-0" x 9'-3"
2'-8" x 8'-0"
102
103
3'-0" x 8'-0"
-----
----
-
SCA2'-8" x 8'-0"
SCA3'-0" x 8'-0"
104A
105A
105B
G
A
0.31 0.28CladDual / T
0.31 0.28
FrontCladDual / T (Courtyard)Front(Courtyard)
2'-8" x 8'-0"
2'-8" x 8'-0"
4'-0" x 9'-6"
9'-8" x 9'-6"
24'-11 12 " 9'-6"
201A
201B
A SC -----
A SC -----
2'-8" x 8'-0"
8'-8" x 8'-0"
2'-6" x 8'-0"
2'-6" x 8'-0"
203A A SC -----
203B E 0.31 0.28CladDual / T
2'-8" x 8'-0"
3'-0" x 8'-0"Front
204 A SC ----2'-6" x 8'-0"
-
D Gls T ---2'-6" x 7'-0"-
205A
205B
A SC -----2'-6" x 8'-0"
206 A SC ----
-
2'-6" x 8'-0"
207A
207B
207C E 0.31 0.28CladDual / T Right -
7'-0" x 8'-0"
2'-8" x 8'-0"
3'-0" x 8'-0"
3'-0" x 8'-0"
9'-8 12 " x 8'-0"209B
-
-
-
D Gls T ---2'-6" x 7'-0"209C
D Gls T ---2'-6" x 8'-0"209D
D Gls T ---2'-6" x 8'-0"209D
-
-
-
210A
210B
-A SC -----2'-6" x 8'-0"
0.31 0.28 BackK Clad Dual / T14'-9 12 " x 8'-0"-
K La Cantina Contemporary CladSliding Pocket Door - 4 equal
T T T
2 Panel Pocket
As required, Refer
to Schedule
2 Panel Pocket
As required, Refer
to Schedule
Door
Door & Window Schedule
DATE ISSUE/REVISION REVIEW
DRAWING DESCRIPTION
PROJECT
All drawings and written material appearingherein constitute original and unpublishedwork of the architect and may not beduplicated, used or disclosed without thewritten consent of Laidlaw Schultz Architects.
3111 Second AvenueCorona del Mar, CA 92625-2322(949) 645-9982 Fax: (949) 645-9554
www.LSarchitects.com
SHEET NO.
Safety Glazing Requirements1
Glazing Impact Test Required
CBC 2406.2 Impact test- Where required by other sections of the code,
glazing shall be tested in accordance with CPSC 16 CFR 1201. Glazing
shall comply with the test criteria for Category I or II as indicated in Table2406.2(1).
EXCEPTION: Glazing not in doors or enclosures for hot tubs, whirlpools,
saunas, steam rooms, bathtubs, and showers shall be permitted to betested in accordance with ANSI Z97.1. Glazing shall comply with the test
criteria for Class A or B as indicated in Table 2406.2(2).
Table 2406.2(1) shows that glazing in swinging, sliding, and bifold doors 9square feet or less shall be a minimum category classification I and
classification II when more than 9 square feet per requirements of
CPSC 16 CFR 1201.
2019 California Building Code
2406.4 Hazardous Locations
The following shall be considered specific hazardous locations for thepurpose of glazing:
1. Glazing in swinging doors except jalousies.2. Glazing in fixed and sliding panels of sliding door assemblies and
panels in sliding and bifold closet door assemblies.3. Glazing in storm doors.
4. Glazing in all unframed swinging doors.5. Glazing in doors and enclosures for hot tubs, whirlpools, saunas,
steam rooms, bathtubs and showers. Glazing in any portion of a buildingwall enclosing these compartments where the bottom exposed edge of
the glazing is less than 60 inches (1524 mm) above a standing surface.6. Glazing in an individual fixed or operable panel adjacent to a
door where the nearest exposed edge of the glazing is within a 24-inch(610mm) arc of either vertical edge of the door in a closed position and
where the bottom exposed edge of the glazing is less than 60 inches(1524mm) above the walking surface.
EXCEPTIONS:1. Panels where there is an intervening wall or other permanent
barrier between the door and glazing.2. Where access through the door is to a closet or storage area 3
feet (914mm) or less in depth. Glazing in this application shall comply withSection 2406.4, Item 7.
3. Glazing in walls perpendicular to the plane of the door in a closedposition, other than the wall towards which the door swings when
opened, in one- and two-family dwellings or within dwelling units in GroupR-2.
7. Glazing in an individual fixed or operable panel, other than thoselocations described in Items 5 and 6, which meets all of the following
conditions:7.1 Exposed area of an individual pane greater than 9 square feet
(0.84 m square)
7.2 Exposed bottom edge less than 18 inches (457 mm) above thefloor.
7.3 Exposed top edge greater than 36 inches (914 mm) above the
floor.7.4 One or more walking surfaces within 36 inches (914 mm)
horizontally of the plane of the glazing.
EXCEPTION: Safety glazing for Item 7 is not required for thefollowing installations:
1. A protective bar 1 1/2 inches (38mm) or more in height, capable
of withstanding a horizontal load of 50 pounds plf (730 N/m) without
contacting the glass, is installed on the accessible sides of the glazing 34
inches to 38 inches (864 mm to 965 mm) above the floor.
2. The outboard pane in insulating glass units or multiple glazingwhere the bottom exposed edge of the glass is 25 feet (7620 mm)or more above any grade, roof, walking surface or other horizontal
or sloped (within 45 degrees of horizontal) (0.78rad) surface
adjacent to the glass exterior.
8. Glazing in guards and railings, including structural baluster panels
and nonstructural in-fill panels, regardless of area or height above awalking surface.
9. Glazing in walls and fences used as the barrier for indoor andoutdoor swimming pools, hot tubs and spas where all of the following
conditions are present:9.1 The bottom edge of the glazing on the pool or spa side is less
than 60 inches (1524 mm) above a walking surface on the poolor spa side of the glazing; and9.2 The glazing is within 60 inches (1524 mm) horizontally of the
water's edge of a swimming pool or spa.10. Glazing adjacent to stairways, landings and ramps within 36 inches
(914mm) horizontally of a walking surface; when the exposed surface of
the glass is less than 60 inches (1524mm) above the plane of the
adjacent walking surface.
11. Glazing adjacent to stairways within 60 inches (1524mm)
horizontally of the bottom tread of a stairway in any direction when the
exposed surface of the glass is less than 60 inches (1524mm) above the
nose of the tread.
EXCEPTION: Safety glazing for Item 10 or 11 is not required for the
following installations where:
1. The side of a stairway, landing, or ramp which has a guardrail orhandrail, including balusters or in-fill panels, complying with the provisions
of Sections 1013 and 1607.7; and2. The plane of the glass is greater than 18 inches (457mm) from the
railing.
2019 California Building Code
2406.4.1 Exceptions
The following products, materials and uses shall not be considered
specific hazardous locations:
1. Openings in doors through which a 3-inch (76mm) sphere is unable
to pass.2. Decorative glass in Section 2406.4, Item 1, 6, or 7.
3. Glazing materials used as curved glazed panels in revolving doors.4. Commercial refrigerated cabinet glazed doors.
5. Glass-block panels complying with Section 2101.2.5.6. Louvered windows and jalousies complying with the requirements
of Section 2403.57. Mirrors and other glass panels mounted or hung on a surface that
provides a continuous backing support.
Mandatory Cal Green Building Standards2
Site Development - CGBSC 4.106.31. Construction plans shall indicate how the site grading or
drainage system will manage all surface water flows to keepwater from entering buildings. Examples of methods to manage
surface water include, but are not limited to, the following:
1.1 Swales
1.2 Water collection and disposal systems
1.3 French drains1.4 Water retention gardens
1.5 Other water measures which keep surface water away from building and aid in groundwater recharge
Indoor Water Use - CGBSC 4.3031. Indoor water fixtures must incorporate the fixture flow rates of
Section 4.303
Fixture Type /Flow RateLavatory faucets 1.5gpm @ 80psi
Kitchen Faucets 1.8gpm @ 80psiWater closets (toilets) 1.28gpm @ 80psi
Showerheads 2gpm @ 80psi
Outdoor Water Use - CGBSC 4.304.11. Irrigation controllers must be weather (rain sensor) or soil
moisture based controllers.
Rodent Proofing - CGBSC 4.406.11. Openings in sole/bottom plates at exterior walls shall be
protected against the passage of rodents by closing suchopenings with cement mortar, concrete masonry or a similar
method acceptable to the enforcing agency.
Construction Waste Reduction - CGBSC 4.4081. A construction waste management plan shall be submitted at
plan check and comply with the Orange County MandatoryConstruction and Demolition Recycling Policy and Program.
Building Maintenance and Operation - CGBSC 4.410
1.0 At final inspection, a manual on building maintenance andoperation must be provided, which includes all of the following:
1.1 Operation and maintenance instructions for all equipment and appliances.
1.2 Roof and yard drainage including gutters and downspouts.
1.3 Space conditioning systems including condensers
and air filters.1.4 Landscape and irrigation systems.1.5 Water reuse systems.
1.6 Recycle programs and locations.
1.7 Public transportation and carpool options.1.8 Educational material on the positive impacts of
maintaining indoor relative humidity between 30 and60 percent.
1.9 Information about water conserving landscape and irrigation design.
1.10 Importance of gutters and downspouts and divertingwater at least 5 ft. from buildings.
1.11 Information on routine maintenance such as caulking,painting, grading, etc.
1.12 Information about state solar energy and incentive programs.
1.13 A copy of all special inspection verifications required by the enforcing agency.
Fireplaces - CGBSC 4.503
1. Gas fireplace must be of the direct-vent sealed-combustionchamber type.
Pollution Control - CGBSC 4.5041. All duct and related distribution component openings must be
covered with tape or other approved means to prevent dustaccumulation.
2. Adhesives, sealants, and caulks must meet minimum VOC limits
(see VOC Limits Handout).
3. Paints and coatings must meet minimum VOC limits (see VOCLimits Handout).
4. Aerosol Paints and coatings shall meet the Product-Weighted
MIR Limits for ROC in Section 94522(a)(3) and other requirements,
including prohibitions on use of certain toxic compounds and
ozone depleting substances, in Sections94522(c)(2) and (d)(2) of California Code of Regulations, Title 17,
commencing with Section 94520.
5. All carpet installed in the building interior shall meet the testing
and product requirements of one of the following:
6. Carpet and Rug Institute's Green Label Plus Program.
7. California Department of Public Health Standard Practice for the testing of VOC's (Spec. 01350).
8. NSF/ANSI 140 at the Gold Level.9. Scientific Certifications Systems Indoor Advantage
Gold.10. All carpet cushion installed in the building interior shall
meet the requirements of the Carpet and Rug Institute Green Label Program.
11. All carpet adhesive shall meet minimum VOC limits (see VOC Limits Handout)
12. Where resilient flooring is installed, at least 80 percent of floor area receiving resilient flooring shall comply
with the VOC emission limits defined in Collaborative
for High Performance Schools (CHPS) Low- emitting
Materials List or certified under the Resilient Floor
Covering Institute (RFCI) Floor Score program.13. Hardwood plywood, particleboard and medium
density fiberboard composite wood products used on the interior or exterior of the building shall meet the
requirements for formaldehyde as specified in ARB's Air Toxics Control Measure for Composite Wood (17 CCR 93120
et seq.), by or before the dates specified in those sections, as shown in Table 4.504.5
Table 4.504.5Formaldehyde Limits in PPM (parts per million)
Product LimitHardwood plywood veneer core 0.05Hardwood plywood composite core 0.05Particleboard0.09Medium Density Fiberboard 0.11Thin Medium Density Fiberboard 0.13
14. Documentation for the items listed above must be
made available to your inspector upon request.
Interior Moisture Control - CGBSC 4.505
1. A capillary break shall be installed and shall consist of thefollowing: a 4-inch thick base of ½ inch or larger clean aggregate
shall be provided with a vapor barrier in direct contact with
concrete and a concrete mix design, which will address bleeding,shrinkage, and curling, shall be used. For additional information,
see American Concrete Institute ACI 302.2R-06. An equivalentslab design by a design professional is acceptable.
Moisture Content of Building Materials - CGBSC 4.505.3
1. Building materials with visible signs of water damage shall notbe installed
2. Wall and floor framing shall not be enclosed when the framingmembers exceed 19 percent moisture content
3. Moisture content shall be verified in compliance with the
following:
3.1 Moisture content shall be determined with either a probe-type or contact-type moisture meter.
3.2 Moisture readings shall be taken at a point 2 feet to 4 feet from the grade stamped end of each piece to
be verified.3.3 At least three random moisture readings shall be
performed on wall and floor framing with provided immediately prior to enclosure of the wall and floor
framing.
4. Insulation products which are visibly wet or have high moisturecontent shall be replaced or allowed to dry prior to enclosure in
wall or floor cavities.
5. Wet-applied insulation products shall follow the manufacturersdrying recommendations prior to enclosure.
Indoor Air Quality and Exhaust - CGBSC 4.506
1. For bathrooms containing a bathtub, shower, or tub/showercombination, a mechanical exhaust fan which exhaust directly
from the bathroom must be installed.
2. Fans must be ENERGY STAR complaint and be ducted to
terminate outside the building.
3. Unless functioning as a component of a whole houseventilation system system, fans must be controlled by humidistat
which shall be readily accessible.
3.1 Humidistat controls shall be capable of adjustment between a relative humidity range of 50 to 80 percent.
Environmental Confort - CGBSC 4.507
2.0 Heating and air-conditioning systems shall be sized, designedand have their equipment selected using the following methods:
2.1 The heat loss and heat gain is established according
to ACCA Manual J, ASHRAE handbooks or other equivalent design software methods.
2.2 Duct systems are sized according to ACCA 29-D Manual D, ASHRAE handbooks or other equivalent
design software or methods.2.3 Select heating and cooling equipment according to
ACCA 36-S Manual S or other equivalent design software or methods.
2.4 Use of alternate design temperatures necessary to ensure the systems function are acceptable.
Door & Window Schedule
DATE ISSUE/REVISION REVIEW
DRAWING DESCRIPTION
PROJECT
All drawings and written material appearingherein constitute original and unpublishedwork of the architect and may not beduplicated, used or disclosed without thewritten consent of Laidlaw Schultz Architects.
3111 Second AvenueCorona del Mar, CA 92625-2322(949) 645-9982 Fax: (949) 645-9554
www.LSarchitects.com
SHEET NO.
CL
L
I
N
D
A
I
S
L
E
LOT 55
LOT 53
N
7
1
°
5
4
'
5
8
"
W
4
5
.
0
0
'
N18°05'02"E 124.00'
N18°05'02"E 124.00'
N
7
1
°
5
4
'
5
8
"
W
4
5
.
0
0
'
DN
DN
DN
DN
54 Linda Isle
APN: 050-461-07Lot 54
(E
)
P
l
a
n
t
e
r
(E
)
P
l
a
n
t
e
r
(E) Off-Street Parking
(E) Off-Street Parking
(E) Driveway
(E) Dock to remain,No proposed work
N 18° 05' 02" E 124.00'
N 18° 05' 02" E 124.00'
Fire Element, max 16" heightRe: Landscape
Existing Tree to beRemoved
(E) Tree to be Removed
26'-0" to Face of Residence
Ne
w
p
o
r
t
B
a
y
Existing Site Wall to
Remain
Existing Site Wall toRemain
Neighboring Residence,
including (E) window locations
Neighboring Residence,including (E) window locations
25'-0" Setback
11'-0" to Face ofResidence
10'-0" Setback
Deck Above
4'
-
0
"
SB
9'-
0
"
4'
-
0
"
SB
Water Feature
(N) Sideyard Gate
(N) Sideyard Gate
AC Condensers
28'-0"
14'-0"
(E) Planter
Line of Interior Garage
Clear space
Setback LineLine of Roof Above
(E)FS: 9.01'
(E)FS: 9.06'
(E)TC: 9.53'
(E)FS: 9.06'
(E)FS: 9.11'
(E)FS: 9.17'
(E)FS: 9.58'
FS: 9.90'
(E)FS: 9.71'
(E)TC: 9.65'
(E)TC: 9.69'
(E)FS: 9.47'
(E)TC: 9.64'
(E)FS: 9.41'
(E) SL
(E)TW: 15.69'(E)TW: 11.33'(E)TW: 11.24'(E)TW: 14.95'(E)TW: 15.32'
(E)TW: 11.70'(E)TW: 11.87'(E)TW: 15.20'
FS: 10.90'
FS: 10.90'
FS: 10.90'
FS: 10.90'
FS: 10.90'
(E)FS: 8.31'
4'
-
8
12"
⅊
⅊
⅊
Note: No building elements may encroachinto common walkway easement, including
roof elements. Existing elements encroachinginto setback can only receive new finish. No
additional elements with the exception ofrain gutters may be added.
Association brick finish must extend to the
face of all building elements. to include faceof building, fence, site walls, raised planters
and on grade planters.
⅊
21'-4" clr.
20
'
-
5
"
c
l
r
.
FS: 10.90'
22'-5"6'-7"10'-0"48'-0"
20
'
-
1
1
"
16
'
-
1
"
9'-6"23'-8"24'-10"
2'-0"
24'-7"4'-5"
21
'
-
7
"
10
'
-
5
"
FF: 10.90'
Established Grade CalculationPer NBZC 20.30.040.B.2
9.79' (#1)
9.78' (#2)9.27' (#3)
+9.22' (#4)38.06' / 4 = 9.52'
Max Height: 33.52' - Flat38.52' - Sloping > 3:12
(E)FS: 9.79'#1
(E)FS: 9.78'#2
(E)FS: 9.27'#3
(E)FS: 9.22'#4
FF: 10.90'
FS: 9.73'
DN
DN
FS: 9.90'
18" max depth
Pl
a
n
t
e
r
Planter Planter on (E) grade
Pl
a
n
t
e
r
PA
PA
PA
PA
Planter
FS: 9.90'FS: 9.90'
FS: 10.90'
5'-
0
"
ACSB
1'
-
0
"
2'
-
3
"
8"
5'
-
8
"
1"
5'
-
9
"
Window
Window Window
Window Window
Win.
Win.
Win.Window Window Window Window Window Window
(N)Gate: 15.69'
(E) TreeNote: Homeowner may be
required to replace tree inassociation landscape island if
trenching for any utility/drainlines damages roots of the tree.
Association brick finish must
extend to the face of all buildingelements. to include face of
building, fence, site walls, raisedplanters and on grade planters.
5'-
0
"
4'
-
0
"
SB
4'
-
0
"
SB
TW: 11.40'
TW: 11.40'
(E)TW: 15.99'
20'-0" Assoc.Parking/Driveway Easement 5'-0"Assoc.Common
WalkwayEase.
CoNB Required Sewer Cleanoutmust be located in public R-O-W,
per STD 406. Cleanout must not beinstalled in Association Easement
for Walkway/Driveway/Parking
Planter on (E)Grade
(E)FS: 9.18'
At raised planter, provide CMU
sub wall adjacent to PL wall per III."ARCHITECTURAL STANDARDS"
section, item no 13h.
T.O. Rail: 14.40'
N
7
1
°
5
4
'
5
8
"
W
4
5
.
0
0
'
Li
n
d
a
I
s
l
e
D
r
i
v
e
℄
Roof Above
Roof Above
Raised planters, max 16" heightRe: Landscape
N
7
1
°
5
4
'
5
8
"
W
4
5
.
0
0
'
New Bulkhead railing,
42" height abv. FS
Scale: 1/8" = 1'-0"1 Site Plan
DATE ISSUE/REVISION REVIEW
DRAWING DESCRIPTION
PROJECT
All drawings and written material appearingherein constitute original and unpublishedwork of the architect and may not beduplicated, used or disclosed without thewritten consent of Laidlaw Schultz Architects.
3111 Second AvenueCorona del Mar, CA 92625-2322(949) 645-9982 Fax: (949) 645-9554
www.LSarchitects.com
SHEET NO.
Site Plan
North
Project Address:
Owner:
Project Description:Existing Single Family Residence to be Demolished
New Single Family Residence
Occupancy:Group R-3/U
Number of Stories:2
Construction:Type V-B, Sprinklered
Zoning District:R-1
Design Professional in
Responsible Charge:
Scott Laidlaw - Laidlaw Schultz Architects
3111 Second Ave Corona Del Mar, CA 92625Phone: 949.645.9982 Fax: 949.645.9554
E-mail: slaidlaw@lsarchitects.com
Gloria Mariman54 Linda Isle
Newport Beach, CA 92660Email: nbgloria@sbcglobal.net
54 Linda IsleNewport Beach, CA 92660
Legal Description:
Assessor's Parcel Number: 050-461-07
Lot 54 of Tract No. 4003
5,580 s.f.
6584.4 s.f.
3,292.2 s.f.
FAR (2 x Buildable Area):
Buildable Area:
Lot Area:
Area Calculation:Proposed
First Floor 1863 sfSecond Floor 2128 sf
Total Living Area 3,991 sfGarage Area: 712 sf
Decks: 311 sf
Building Height:26'-0"
Parking:2 Covered
600 s.f. (600 > 493.8 - 15% of Buildable Area)Open Volume Area:
General Notes3
1. Provide 2% slope grade away from structures within 5'-0" of structure.
2. Provide approved backwater drainage valve for fixtures located below the elevation of next upstream manholecover. Fixtures above this elevation shall not discharge through valve.
3. All downspouts, area drains and planter drains to be connected to solid drainlines and conveyed to street or tosump and pumped back to street.
4. An approved encroachment permit is required for all work activities within the public right-of-way.
5. If any of the existing public improvements surrounding the site is damaged, new concrete sidewalk, curb and gutter,alley/street pavement, and other public improvements will be required by the City at the time of privateconstruction completion. Additionally, if existing utilities infrastructure are deemed substandard, a new 1-inch waterservice, water meter box, sewer lateral and/or cleanout with box and lid will be required. 100% of the cost shall beborne by the property owner (Municipal Codes 14.24.020 and 14.08.030). Said determination and the extent of therepair work shall be made at the discretion of the Public Works Inspector.
6. An encroachment agreement is required for all non-standard improvements within the public right-of-way. Allnon-standard improvements shall comply with City Council Policy L-6
7. All work related to water in the public right-of-way shall be performed by a C-34 licensed Pipeline Contractor of anA Licensed General Engineering Contractor.
8. All work related to wastewater in the public right-of-way shall be performed by a C-42 licensed Sanitation SewerContractor or an A Licensed General Engineering Contractor.
9. Contractor shall provide drip pans throughout construction for workers cars. Contractor shall be responsible for anydamage to pavers in adjacent parking stalls
10. The Association will not approve the use of the 5'-0" walkway or 20'-0" driveway/Guest parking/ Planter easement forhomeowner purposes. Filtration Systems must be within the property, not in the 20'-0" driveway/parking or the 5'-0"Association walkway easement.
11. The Association does not approve any water filtration apparatus within the association planters.
12. If the City requires a trench drain at the end of the driveway and guest parking, the Association will allow theinstallation. Trench drain must be depicted on your plans submitted to Association. Submit trench drain sectionspecification for Association approval.
13. Contractor shall schedule pre-construction meeting with Architectural administrator to observe pre-constructioncondition of Association elements
Project Data2Vicinity Map5 Scope of Work4Scale: 1" = 28'-0"
1. Demolish existing single-family residence
2. New Single Family Residence with attached garage
3. New Bulkhead extension per Newport Beach Standards
UP
DN
DN
DN
DN
DN100
Garage
FF: 10.00'
102
Powder
103
Laundry
-
Courtyard
104
Dining Room
107
Foyer
109
Living Room
108
Kitchen
105
Back Kitchen
106
Pantry
Fountain
FF: 10.90'
FF:
10.90'-Terrace
⅊
⅊
⅊
87'-0"
48'-0"10'-0"6'-7"22'-5"
1'-0"
3'
-
3
"
2'
-
3
"
2'-0"22'-5"8'-7"15'-0"
36
'
-
4
"
5'-
8
"
25
'
-
0
"
5'
-
8
"
23'-8"24'-10"24'-7"
21
'
-
7
"
10
'
-
8
"
4'
-
9
"
4'-5"
4'-5"
30
'
-
1
0
"
c
l
r
.
11'-1"4'-5"
10
'
-
5
"
20
'
-
5
"
5'
-
7
"
13
'
-
1
0
"
1'
-
0
"
11
'
-
0
"
10'-0"
9'-6"
5'-0"
4'
-
1
0
"
11
'
-
1
"
15'-0"4'-10"
6'-6"
14'-7"
16
'
-
1
"
812"
10
'
-
3
"
4'
-
6
"
9'
-
4
"
5'
-
1
1
"
3'-6"10'-0"8'-11"
22'-5"8'-2"
5'-
1
0
"
13'-3"
4'-8"11'-7"
4'-10"4'-4"
5'
-
0
"
4'-
3
"
8'-7"20'-8"4'
-
6
"
5'
-
5
"
4'
-
4
"
5'-
6
"
14'-5"10'-7"
12
'
-
3
"
4'-
1
0
"
4'-4"6'-6"A.4003
A.
4
0
0
1
A.
4
0
0
1
A.
4
0
0
2
A.
4
0
0
2
A.4003
A.3003
A.3011
A.
3
0
0
1 A.
3
0
0
2
1'-0"
100A
100C
103
102
100B
104B
105B 105A
109
107A
107B
104A
000A
000B
11102742415
25
26
39
4 2411101135
30
1720R@7.05"7
7
38
37
32
10
2
3
18
10
11
23
22
7
6
6
6
9
48 48
4'-4"
4'-2"
1510
2'
-
0
"
7'
-
1
"
2'-
0
"
2'-3"
8'-8"3'-11"
G
53
4'-10"
6'-5"5'-11"
FS: 9.80'
FS: 9.90'
FS: 10.13'
25'-0" Association Easement
10'-0" 'Front'
Association Easement
10'-0" Deck Setback
26'-0"
1'-0"
11'-0"
1'-0"
4'
-
0
"
A
s
s
o
c
.
Se
t
b
a
c
k
4'-
0
"
55
56
56
55
55 56
55
56
55 565556
Project T-24 Orientation
Right
Left
Front Back
C1 C2 C3 C4
C5 C6
C7
1'-9"4'-2"3'-11"3'-7"
1'-7"
C8
Cl.104C
·All dimensions are to be to the finished face or centerline of thepartition U.N.O.
·G.C. to layout (in paint) the locations of all partitions, doors, lighting,ceiling elements, sprinklers, switches, dimmers, thermostats, power &comm. outlets, millwork and furniture for approval by the Architect priorto construction.
·It is the responsibility of the contractor to bring to the attention ofthe Architect any field conditions that do not allow construction orinstallation as drawn.
·Do not scale drawings. Dimensions as indicated take precedentover drawings.
·Provide continuous metal backing for reinforcing of walls to hangmillwork, furniture shelving or cabinetry.
·Provide millwork shop drawings for Architect's approval. Millwork tocomply with the recommendations of the Woodwork Institute ofCalifornia (WIC).
·Any door hardware associated with millworker provided doors is tobe ordered by the millworker.
·G.C. to provide full-time superintendents' supervision on the project.
·For pre-fabricated stairs, shop drawings to be approved by BuildingPlan Check prior to installation
·G.C. to schedule meeting with HOA Architectural Administrator attime of roofing material delivery to confirm conforming metal roofingmaterial.
Note: All new wall cavities to be fully filled w/
insulation. Coordinate w/ Title 24.
1. Tub, Shower, or Tub/Shower combination w.
anti-scalding fixtures. Provide 12" round
cleanouts. Wall covering of shower shall be tile,
or approved equal, to a height of min. 72" abv.
drain inlet. Float tile over cement plasterbacking. Single shower head not to exceed 2
gpm at 80psi. Multiple shower heads combinedflow rate not to exceed 2gpm at 80psi.
2. Water Closet - 1.28 gallon /flush to meetstandards set by American National Inst. Stds.
A112.19.2 H and S Code. Conceal water supply.Provide 30" clear width & 24" min. clear in front of
watercloset. Provide adjacent area drain.3. Lavatory - 1.5 gpm at 80psi
4. Kitchen Sink & garbage disposal w/ Faucet - Not
to exceed 1.5 gpm @ 60 psi. Provide Instahot andwater filtration
5. Line of Rafters above6. Line of roof above
7. Line of soffit above8. Concealed Gutter & Downspout, tie to hard line
drainage system9. Line of floor, deck above
10. Built-in cabinet & counter @ +36" AFF11. Upper cabinets
12. Pole and shelf
13. Combo Area and Overflow roof drain14. NOT USED
15. Full height Millwork16. 34"-38" high handrail
17. +42" high guardrail18. Utility Sink
19. Location for future solar panels, 40"x64"
20. Provide min. 5/8" Type 'X' GWB @ underside of
floor framing, abv.21. Isokern 46" Maximus Series Direct Vent
(80D46)(Gas-Only) Fireplace & Chimney System.Tested & Listed by ICC ESR-4873. Re: A.001f for
Specs & Certification22. Washing machine. Shall be qualified ENERGY
STAR appliance with maximum water use factorof 6 gallons per cubic feet of drum capacity
(NBMC 15.11.010)23. Clothes dryer. 4" Ø vent w/ max. (2) 90° bends,
14' max run. Exhaust vent duct shall terminate at
exterior of building. Equip w/ back draft damper.24. Dishwasher shall be qualified ENERGY STAR
appliance with maximum water use as follows(NBMC 15.11.010) Standard Dishwasher: 4.25
gallons per cycle, Compact Dishwashers: 3.5gallons per cycle
25. Scheduled Integrated 30" built-in Refrigerator26. Scheduled Integrated 30" built-in Freezer
27. 48" Professional Range w/ exhaust hood28. Utility Sink
29. LED Television, owner supplied. Provide backingas required for wall mounting. Provide conduit to
A/V cabinet.
30. Pantry shelves31. Pull-out trash drawer32. Bar Sink
33. Combo Area and Overflow deck drains
34. Mirror, Re: Interiors35. Built-in Cabinet & counter @+42" AFF
36. Built-in Cabinet & counter @+24" AFF
37. Under Counter Ice Maker38. Under Counter Refrigerator
39. Elevator machine space - Pump & Controller.
Provide min clear space 36" x 30" space locateddirectly in front of controller.
40. Shade Pocket41. Mantle42. Hearth
43. Specified pavers o/ pedestals o/ Dex-O-Texwaterproof membrane ICC# ESR-1757. Slope to
drain, 2% min.
44. Shower niche, Re: Interiors45. Bench, +18" AFF
46. Electric Meter, Re: Electrical
47. HVAC chase as req'd. Coordinate w. MEP &
Arch. prior to construction. Firestop @ floorpenetration per mfr specifications.
48. A/C units, Re: T-24 requirements, Acousticalreport & MEP. Provide AC disconnect. AC type
and location require a deferred submittal forreview and approval for a separate permit.
Separate permit must be obtained prior torunning refrigeration lines, electrical
conduit/conductors and disconnect.
49. Built-in Shelves50. Attic Access - 22" x 30" min.
51. Class 'A' Flintlastic Modified Bitumen roofcovering by Certainteed, ICC# ESR-1388.
52. 16 oz. Natural-aging Copper Standing seamroofing o/ Certainteed Metalayment 60 mil.
underlayment. ICC ESR-1492.
53. Tankless Water Heater; Provide 120V electrical
receptacle w/in 3 feet, Cat. III or IV vent, or Type
B vent w/ straight pipe, Condensate drain that is
no more than 2 inches higher than the finish
surface below, and a gas supply line withavailable copacity for not less than a 200,000
BTU/hr system.54. +42" Partial height wall guardrail
55. Internal downspout, Overflow to be pipedseparately.
56. Bronze Downspout nozzle by Jay R. Smith MFG.Co.
Fire Seperation Wall - 1/2"
min GWB shall be applied
to garage side
2x4 Stud Wall
2x6 Stud Wall
Concrete Retaining wall
Re: Struct. for thicknessProvide GWB o/ furring
channel & Insul. per T-24.
Board Formed Concretewall
Scale: 1/4" = 1'-0"1 First Floor Plan
DATE ISSUE/REVISION REVIEW
DRAWING DESCRIPTION
PROJECT
All drawings and written material appearingherein constitute original and unpublishedwork of the architect and may not beduplicated, used or disclosed without thewritten consent of Laidlaw Schultz Architects.
3111 Second AvenueCorona del Mar, CA 92625-2322(949) 645-9982 Fax: (949) 645-9554www.LSarchitects.com
SHEET NO.
Floor Plans
Notes5 General Notes Legend23Plan Notes4
·All dimensions are to be to the finished face or centerline of thepartition U.N.O.
·G.C. to layout (in paint) the locations of all partitions, doors, lighting,ceiling elements, sprinklers, switches, dimmers, thermostats, power &comm. outlets, millwork and furniture for approval by the Architect priorto construction.
·It is the responsibility of the contractor to bring to the attention ofthe Architect any field conditions that do not allow construction orinstallation as drawn.
·Do not scale drawings. Dimensions as indicated take precedentover drawings.
·Provide continuous metal backing for reinforcing of walls to hangmillwork, furniture shelving or cabinetry.
·Provide millwork shop drawings for Architect's approval. Millwork tocomply with the recommendations of the Woodwork Institute ofCalifornia (WIC).
·Any door hardware associated with millworker provided doors is tobe ordered by the millworker.
·G.C. to provide full-time superintendents' supervision on the project.
·For pre-fabricated stairs, shop drawings to be approved by BuildingPlan Check prior to installation
·G.C. to schedule meeting with HOA Architectural Administrator attime of roofing material delivery to confirm conforming metal roofingmaterial.
Note: All new wall cavities to be fully filled w/insulation. Coordinate w/ Title 24.
1. Tub, Shower, or Tub/Shower combination w.anti-scalding fixtures. Provide 12" round
cleanouts. Wall covering of shower shall be tile,or approved equal, to a height of min. 72" abv.
drain inlet. Float tile over cement plaster
backing. Single shower head not to exceed 2gpm at 80psi. Multiple shower heads combined
flow rate not to exceed 2gpm at 80psi.2. Water Closet - 1.28 gallon /flush to meet
standards set by American National Inst. Stds.A112.19.2 H and S Code. Conceal water supply.
Provide 30" clear width & 24" min. clear in front ofwatercloset. Provide adjacent area drain.
3. Lavatory - 1.5 gpm at 80psi4. Kitchen Sink & garbage disposal w/ Faucet - Not
to exceed 1.5 gpm @ 60 psi. Provide Instahot andwater filtration
5. Line of Rafters above
6. Line of roof above7. Line of soffit above
8. Concealed Gutter & Downspout, tie to hard linedrainage system
9. Line of floor, deck above10. Built-in cabinet & counter @ +36" AFF
11. Upper cabinets12. Pole and shelf
13. Combo Area and Overflow roof drain14. NOT USED
15. Full height Millwork
16. 34"-38" high handrail
17. +42" high guardrail
18. Utility Sink
19. Location for future solar panels, 40"x64"20. Provide min. 5/8" Type 'X' GWB @ underside of
floor framing, abv.21. Isokern 46" Maximus Series Direct Vent
(80D46)(Gas-Only) Fireplace & Chimney System.
Tested & Listed by ICC ESR-4873. Re: A.001f forSpecs & Certification
22. Washing machine. Shall be qualified ENERGYSTAR appliance with maximum water use factor
of 6 gallons per cubic feet of drum capacity(NBMC 15.11.010)
23. Clothes dryer. 4" Ø vent w/ max. (2) 90° bends,14' max run. Exhaust vent duct shall terminate at
exterior of building. Equip w/ back draft damper.24. Dishwasher shall be qualified ENERGY STAR
appliance with maximum water use as follows
(NBMC 15.11.010) Standard Dishwasher: 4.25gallons per cycle, Compact Dishwashers: 3.5
gallons per cycle25. Scheduled Integrated 30" built-in Refrigerator
26. Scheduled Integrated 30" built-in Freezer27. 48" Professional Range w/ exhaust hood
28. Utility Sink29. LED Television, owner supplied. Provide backing
as required for wall mounting. Provide conduit toA/V cabinet.
30. Pantry shelves31. Pull-out trash drawer
32. Bar Sink33. Combo Area and Overflow deck drains
34. Mirror, Re: Interiors35. Built-in Cabinet & counter @+42" AFF
36. Built-in Cabinet & counter @+24" AFF37. Under Counter Ice Maker
38. Under Counter Refrigerator39. Elevator machine space - Pump & Controller.
Provide min clear space 36" x 30" space locateddirectly in front of controller.
40. Shade Pocket41. Mantle
42. Hearth43. Specified pavers o/ pedestals o/ Dex-O-Tex
waterproof membrane ICC# ESR-1757. Slope todrain, 2% min.
44. Shower niche, Re: Interiors45. Bench, +18" AFF
46. Electric Meter, Re: Electrical47. HVAC chase as req'd. Coordinate w. MEP &
Arch. prior to construction. Firestop @ floorpenetration per mfr specifications.
48. A/C units, Re: T-24 requirements, Acoustical
report & MEP. Provide AC disconnect. AC typeand location require a deferred submittal for
review and approval for a separate permit.Separate permit must be obtained prior to
running refrigeration lines, electricalconduit/conductors and disconnect.
49. Built-in Shelves50. Attic Access - 22" x 30" min.
51. Class 'A' Flintlastic Modified Bitumen roof
covering by Certainteed, ICC# ESR-1388.52. 16 oz. Natural-aging Copper Standing seam
roofing o/ Certainteed Metalayment 60 mil.underlayment. ICC ESR-1492.
53. Tankless Water Heater; Provide 120V electricalreceptacle w/in 3 feet, Cat. III or IV vent, or Type
B vent w/ straight pipe, Condensate drain that isno more than 2 inches higher than the finish
surface below, and a gas supply line with
available copacity for not less than a 200,000BTU/hr system.
54. +42" Partial height wall guardrail55. Internal downspout, Overflow to be piped
separately.56. Bronze Downspout nozzle by Jay R. Smith MFG.Co.
Fire Seperation Wall - 1/2"min GWB shall be applied
to garage side
2x4 Stud Wall
2x6 Stud Wall
Concrete Retaining wall
Re: Struct. for thicknessProvide GWB o/ furring
channel & Insul. per T-24.
Board Formed Concretewall
DN
200
Bedroom
FF: 22.65'
203
Bedroom
201
Bath
202
Closet
204
Closet
206
Linen
205
Bath
207
Study/Gym 208
Master Closet
-Deck
210
Master Bedroom
-Deck
209
Master Bath
FF:
22.65'
FF: 22.65'
-Deck
FS: 22.65'
FS: 22.65'
T.O. Trellis: 23.25'
⅊
⅊
⅊
36
'
-
4
"
5'
-
8
"
5'
-
8
"
82'-7"4'-5"1'-0"
25'-0"33'-0"24'-7"
31
'
-
0
"
48'-0"34'-7"
10'-0"15'-0"15'-6"17'-6"8'-0"16'-7"
14
'
-
1
0
"
5"
5"
9'-6"7'-0"8'-6"
8'-2"
16
'
-
1
"
8'-0"5'-0"5'-0"5'-0"5'-0"5'-0"
2'-3"
11'-11"12'-8"
7'-
1
"
2'-
0
"
2'
-
0
"
10
'
-
5
"
15
'
-
9
"
4'
-
1
0
"
20
'
-
7
"
6'-0"11'-6"
3'
-
3
"
5'-0"5'-0"
15
'
-
3
"
4'
-
6
"
10'-0"15'-0"4'-9"11'-3"
8'-0"6'-0"
2'
-
6
"
8'
-
6
"
19
'
-
0
"
13'-0"4'-4"3'-6"
4'
-
6
"
10
'
-
3
"
5'
-
1
"
6'-
0
"
9'
-
4
"
9'-6"5'-5"15'-11"
7'
-
4
"
9R
@
7
.
0
5
"
4'
-
0
"
4'-
1
0
"
4'-0"1'-4"4'-0"
11'-11"
5'-
8
"
5'-
0
"
4'
-
6
"
14
'
-
8
"
12'-8"7'-0"4'-4"
10
"
5'
-
5
"
8'
-
5
"
5'
-
1
"
3'-0"11'-6"
A.4003
A.
4
0
0
1
A.
4
0
0
1
A.
4
0
0
2
A.
4
0
0
2
A.4003
A.3003
A.3011
A.
3
0
0
1 A.
3
0
0
2
200B 200A
203A203B
204
206
205B205A
202
201A
201B
207A
207B
208
210A
210B
209A
209D
209E
209C
209B
207C
210C
7'-10"3'-0"
FS: 22.65'
39
20R@7.05"17 16
6
6
6
17
17
54
6 6
6
1
3
10
2
1
103
2 10 3
1
1
10 32
1515
57
5
5
5
7
2
33
33
33
33
25
'
-
0
"
9"
5'
-
8
"
9'
-
9
"
3'-10"4'-10"5'-3"2'-4"8'-7"
7'
-
1
1
"
2'
-
6
"
14'-7"6'-1"2'-11"4'-7"4'-7"
3'-6"4'-0"
7'-10"7'-8"2'-11"
9'-
8
"
6"
8'-0"
6'-8"1'-9"4'-7"4'-8"
5"
15
15
25'-0" Association Easement
10'-0" 'Front'
Association Easement
10'-0" Deck Setback
1'-0"
812"
4'
-
0
"
A
s
s
o
c
.
Se
t
b
a
c
k
4"
2'
-
3
"
11
"
4'
-
0
"
A
s
s
o
c
.
Se
t
b
a
c
k
5'
-
0
"
5'
-
0
"
1'
-
0
"
4'
-
0
"
A
s
s
o
c
.
Se
t
b
a
c
k
1'
-
0
"
4'
-
0
"
A
s
s
o
c
.
Se
t
b
a
c
k
5'-5"
4'-2"11"4'-2"4"4"
WindowWindowWindowWindowWindowWindow
Window
Window
43
43
43
55
52 13
13
13 13
55
55
55
55
55
Project T-24 Orientation
Right
Left
Front Back
C14C15C16C19C18C17
C20C21
D2 D1
B10
B11
abv.
abv.
B12
abv.
B13
abv.
B14
abv.
B15
abv.
B16
abv.
B4
abv.
B3
abv.
B2
abv.
B1
abv.
C13C12
C9 C10 C11
B5 B6 B7 B8 B9
A1
Scale: 1/4" = 1'-0"1 Second Floor Plan
Floor Plans
DATE ISSUE/REVISION REVIEW
DRAWING DESCRIPTION
PROJECT
All drawings and written material appearingherein constitute original and unpublishedwork of the architect and may not beduplicated, used or disclosed without thewritten consent of Laidlaw Schultz Architects.
3111 Second AvenueCorona del Mar, CA 92625-2322(949) 645-9982 Fax: (949) 645-9554
www.LSarchitects.com
SHEET NO.
Notes5 General Notes Legend23Plan Notes4
·All dimensions are to be to the finished face or centerline of thepartition U.N.O.
·G.C. to layout (in paint) the locations of all partitions, doors, lighting,ceiling elements, sprinklers, switches, dimmers, thermostats, power &comm. outlets, millwork and furniture for approval by the Architect priorto construction.
·It is the responsibility of the contractor to bring to the attention ofthe Architect any field conditions that do not allow construction orinstallation as drawn.
·Do not scale drawings. Dimensions as indicated take precedentover drawings.
·Provide continuous metal backing for reinforcing of walls to hangmillwork, furniture shelving or cabinetry.
·Provide millwork shop drawings for Architect's approval. Millwork tocomply with the recommendations of the Woodwork Institute ofCalifornia (WIC).
·Any door hardware associated with millworker provided doors is tobe ordered by the millworker.
·G.C. to provide full-time superintendents' supervision on the project.
·For pre-fabricated stairs, shop drawings to be approved by BuildingPlan Check prior to installation
·G.C. to schedule meeting with HOA Architectural Administrator attime of roofing material delivery to confirm conforming metal roofingmaterial.
Note: All new wall cavities to be fully filled w/insulation. Coordinate w/ Title 24.
1. Tub, Shower, or Tub/Shower combination w.anti-scalding fixtures. Provide 12" round
cleanouts. Wall covering of shower shall be tile,or approved equal, to a height of min. 72" abv.
drain inlet. Float tile over cement plaster
backing. Single shower head not to exceed 2gpm at 80psi. Multiple shower heads combined
flow rate not to exceed 2gpm at 80psi.2. Water Closet - 1.28 gallon /flush to meet
standards set by American National Inst. Stds.A112.19.2 H and S Code. Conceal water supply.
Provide 30" clear width & 24" min. clear in front ofwatercloset. Provide adjacent area drain.
3. Lavatory - 1.5 gpm at 80psi4. Kitchen Sink & garbage disposal w/ Faucet - Not
to exceed 1.5 gpm @ 60 psi. Provide Instahot andwater filtration
5. Line of Rafters above
6. Line of roof above7. Line of soffit above
8. Concealed Gutter & Downspout, tie to hard linedrainage system
9. Line of floor, deck above10. Built-in cabinet & counter @ +36" AFF
11. Upper cabinets12. Pole and shelf
13. Combo Area and Overflow roof drain14. NOT USED
15. Full height Millwork
16. 34"-38" high handrail
17. +42" high guardrail
18. Utility Sink
19. Location for future solar panels, 40"x64"20. Provide min. 5/8" Type 'X' GWB @ underside of
floor framing, abv.21. Isokern 46" Maximus Series Direct Vent
(80D46)(Gas-Only) Fireplace & Chimney System.
Tested & Listed by ICC ESR-4873. Re: A.001f forSpecs & Certification
22. Washing machine. Shall be qualified ENERGYSTAR appliance with maximum water use factor
of 6 gallons per cubic feet of drum capacity(NBMC 15.11.010)
23. Clothes dryer. 4" Ø vent w/ max. (2) 90° bends,14' max run. Exhaust vent duct shall terminate at
exterior of building. Equip w/ back draft damper.24. Dishwasher shall be qualified ENERGY STAR
appliance with maximum water use as follows
(NBMC 15.11.010) Standard Dishwasher: 4.25gallons per cycle, Compact Dishwashers: 3.5
gallons per cycle25. Scheduled Integrated 30" built-in Refrigerator
26. Scheduled Integrated 30" built-in Freezer27. 48" Professional Range w/ exhaust hood
28. Utility Sink29. LED Television, owner supplied. Provide backing
as required for wall mounting. Provide conduit toA/V cabinet.
30. Pantry shelves31. Pull-out trash drawer
32. Bar Sink33. Combo Area and Overflow deck drains
34. Mirror, Re: Interiors35. Built-in Cabinet & counter @+42" AFF
36. Built-in Cabinet & counter @+24" AFF37. Under Counter Ice Maker
38. Under Counter Refrigerator39. Elevator machine space - Pump & Controller.
Provide min clear space 36" x 30" space locateddirectly in front of controller.
40. Shade Pocket41. Mantle
42. Hearth43. Specified pavers o/ pedestals o/ Dex-O-Tex
waterproof membrane ICC# ESR-1757. Slope todrain, 2% min.
44. Shower niche, Re: Interiors45. Bench, +18" AFF
46. Electric Meter, Re: Electrical47. HVAC chase as req'd. Coordinate w. MEP &
Arch. prior to construction. Firestop @ floorpenetration per mfr specifications.
48. A/C units, Re: T-24 requirements, Acoustical
report & MEP. Provide AC disconnect. AC typeand location require a deferred submittal for
review and approval for a separate permit.Separate permit must be obtained prior to
running refrigeration lines, electricalconduit/conductors and disconnect.
49. Built-in Shelves50. Attic Access - 22" x 30" min.
51. Class 'A' Flintlastic Modified Bitumen roof
covering by Certainteed, ICC# ESR-1388.52. 16 oz. Natural-aging Copper Standing seam
roofing o/ Certainteed Metalayment 60 mil.underlayment. ICC ESR-1492.
53. Tankless Water Heater; Provide 120V electricalreceptacle w/in 3 feet, Cat. III or IV vent, or Type
B vent w/ straight pipe, Condensate drain that isno more than 2 inches higher than the finish
surface below, and a gas supply line with
available copacity for not less than a 200,000BTU/hr system.
54. +42" Partial height wall guardrail55. Internal downspout, Overflow to be piped
separately.56. Bronze Downspout nozzle by Jay R. Smith MFG.Co.
Fire Seperation Wall - 1/2"min GWB shall be applied
to garage side
2x4 Stud Wall
2x6 Stud Wall
Concrete Retaining wall
Re: Struct. for thicknessProvide GWB o/ furring
channel & Insul. per T-24.
Board Formed Concretewall
Roof Plan Notes:
1.Attic Ventilation: No ventilation is required, see below for unvented assembly.
Unvented Attic Assemblies: Per R806.5 the attic assemblies may be unvented under the followingconditions:
A. The unvented attic space must be completely within the building thermal envelope.
B. No interior vapor retarders are installed on the ceiling side (attic floor) of the unvented attic assembly
C. Provide Icynene Classic (LD-C-50) Spray Foam air impermeable insulation only shall be installed on the
underside of the structural roof sheathing.
2.Exposed attic insulation: All exposed insulation materials installed on attic floors shall have a critical radiant
flux of not less than 0.12 watt per square centimeter per ASTM E 970
3.Standing Seam Metal Roof:
Material: Copper, 16 oz sheets min.
Finish: Natural aging
A.Underlayment: MetaLayment by Certainteed, ICC# ESR-1492. Install per Mnft. specs.
Ridge: 36.05'
Ri
d
g
e
:
3
6
.
8
0
'
Ri
d
g
e
:
3
6
.
8
0
'
Eave: 33.80'
Eave: 33.80'
Eave: 33.80'
Eave: 33.80'Eave: 33.80'
Eave: 33.80'
Eave: 33.80'
Facia: 33.65'
Facia: 33.65'
Fa
c
i
a
:
3
3
.
6
5
'
Fa
c
i
a
:
3
3
.
6
5
'
Fa
c
i
a
:
3
3
.
6
5
'
Facia: 33.65'
T.O. Trellis: 23.25'
T.O.Flue:38.30'
T.O. Flue: 37.63'
T.O. Flue: 37.63'
⅊
⅊
⅊
3:12 3:12
3:123:12
3:
1
2
3:
1
2
3:
1
2
3:
1
2
3:
1
2
3:
1
2
Ea
v
e
:
3
3
.
8
0
'
Ea
v
e
:
3
3
.
8
0
'
Facia: 33.65'
A.4003
A.
4
0
0
1
A.
4
0
0
1
A.
4
0
0
2
A.
4
0
0
2
A.4003
A.3003
A.3011
A.
3
0
0
1 A.
3
0
0
2
52
52
52
Facia: 33.65'
WindowWindowWindowWindowWindowWindow
Window
Window
25'-0" Association Easement 10'-0" 'Front'Association Easement
10'-0" Deck Setback
11"9'-1"
11
"
4'
-
0
"
A
s
s
o
c
.
Se
t
b
a
c
k
3'
-
1
"
1'
-
0
"
4'
-
0
"
A
s
s
o
c
.
Se
t
b
a
c
k
4'
-
0
"
A
s
s
o
c
.
Se
t
b
a
c
k
3'-6"
212"
4'
-
0
"
A
s
s
o
c
.
Se
t
b
a
c
k
3'
-
9
12"
8
8
8
8
8
88
Scale: 1/4" = 1'-0"1 Roof Plan
Roof Plan
Roof Notes / Attic Ventilation Calculation5
DATE ISSUE/REVISION REVIEW
DRAWING DESCRIPTION
PROJECT
All drawings and written material appearingherein constitute original and unpublishedwork of the architect and may not beduplicated, used or disclosed without thewritten consent of Laidlaw Schultz Architects.
3111 Second AvenueCorona del Mar, CA 92625-2322(949) 645-9982 Fax: (949) 645-9554
www.LSarchitects.com
SHEET NO.
General Notes Legend23Plan Notes4
⅊⅊
Smooth Integral Color
Stucco
Painted MetalGuardrail
Standing Seam Metal Roof
Southern Buff Limestone Veneer
Painted Metal Fascia
Stained Wood Rafters
Southern Buff Limestone Veneer
Stained Wood Garage Door to Match Siding
Ptd. Aluminum CladWindows & Doors, typ.
Painted Metal Fascia
Concealed GutterSystem
10
'
-
1
0
"
26
'
-
0
"
3'
-
6
"
m
i
n
.
3
12
3
12
Max. Height
EL: 36.80'
(E) Second Floor
EL: 22.65'
Garage Floor(E)EL: 9.90'
First FloorEL: 10.90'
2nd Floor Top Plate
EL: 31.40'
Natural-aging Copper Eave Fascia
A1
B1 B2 B3 B4
200B 203B
100A000A 000B
Smooth Integral color Stucco
Mtl. Guardrail with
Clear glass infill
Ptd. Aluminum CladWindows & Doors, typ.
Standing Seam Metal Roof
Metal Fascia
Stained Wood Rafter
Painted Metal Fascia
at Deck
Concealed Gutter System
AC AC
Ptd. Metal Guardrail
3
12
3
123
12
25'-0" Association Easement
10'-0" 'Front'
Association Easement
⅊
Max. HeightEL: 36.80'
(E) Second Floor
EL: 22.65'
Garage Floor(E)EL: 9.90'
First FloorEL: 10.90'
2nd Floor Top PlateEL: 31.40'
Line of Existing Sideyard
Southern Buff Limestone Veneer
DS DS DS OF
3'-
6
"
m
i
n
.
Natural-aging Copper Eave Fascia
C8
D1 D2
C14 C15 C16 C17 C18 C19 C20 C21
100B
⅊⅊
Standing Seam Metal Roof
Painted Metal Fascia
Stained Wood Rafters
Smooth Integral Color Stucco
Ptd. Aluminum Clad Windows & Doors, typ.
Mtl. Guardrail with Clear glass infill
Concealed Gutter System
Ptd. Metal Fascia at Deck
3'
-
6
"
m
i
n
.
3
12
3
12
Max. Height
EL: 36.80'
(E) Second Floor
EL: 22.65'
Garage Floor(E)EL: 9.90'
First FloorEL: 10.90'
2nd Floor Top Plate
EL: 31.40'
Natural-aging Copper Eave Fascia
B10 B11 B12 B13 B13
109
210B 209B
Scale: 1/4" = 1'-0"1
DATE ISSUE/REVISION REVIEW
DRAWING DESCRIPTION
PROJECT
All drawings and written material appearingherein constitute original and unpublishedwork of the architect and may not beduplicated, used or disclosed without thewritten consent of Laidlaw Schultz Architects.
3111 Second AvenueCorona del Mar, CA 92625-2322(949) 645-9982 Fax: (949) 645-9554
www.LSarchitects.com
SHEET NO.
Elevations
Scale: 1/4" = 1'-0"3
West Elevation (Front)
North Elevation (Left)
2 East Elevation (Back)
Standing Seam Metal Roof
Painted Metal Fascia
Concealed Gutter System
Stained Wood Rafter
Painted Metal Guardrail
Ptd. Aluminum CladWindows & Doors, typ.
Ptd. Steel Trellis
Southern Buff Limestone Veneer
Painted Metal Fascia
Smooth Integral color Stucco
Stained Wood Siding 10
'
-
1
0
"
3
12
3
12
3
123
12
25'-0" Association Easement
10'-0" 'Front'
Association Easement
⅊
Max. Height
EL: 36.80'
(E) Second Floor
EL: 22.65'
Garage Floor(E)EL: 9.90'
First FloorEL: 10.90'
2nd Floor Top Plate
EL: 31.40'
Line of Existing Sideyard
DS OF DS OF DS OF
Natural-aging Copper Eave Fascia
C1 C2 C3 C4 C5 C6 C7
C13C12C9C10C11B5B6B7B8B9
104A
207C
Exterior Stucco
Mnft: La HabraColor: Eggshell X-73
Finish: Smooth SBMF
Standing Seam Metal Roofing
Material: 16 oz CopperFinish: Natural-aging
Spec: 1.5" ribs, 16" o.c.
Location: Roofing
GuttersEave Fascia
Aluminum Clad Windows + Doors
Window Mnft: KolbeStyle: VistaLuxe WD Line
Color: TruffleGlazing: Clear, Argon-filed
Door Mnft: Arcadia
Style: Steel Look
Color: Match Kolbe
Adhered Natural Stone Veneer
Supplier: Modern Builders Supply
Collection: Southern Buff
Limestone
Size: Height- 16"
Length- Varies 3'-6" to 3'-7"
Stained Wood
Location: Garage Door Site Gates
Wall Siding
Finish:Quarter Sawn
Stained
Metal Handrails + Guardrails,Fascia, & Trellis
Mnft: Firestone
Style: UNA-CLAD
Material: AluminumColor Extra Dark Bronze
⅊⅊
3'
-
6
"
m
i
n
.
3
12
3
12
Max. Height
EL: 36.80'
(E) Second Floor
EL: 22.65'
Garage Floor(E)EL: 9.90'
First FloorEL: 10.90'
2nd Floor Top PlateEL: 31.40'
New Bulkhead Guardrail, +42"
above FS. Steel top rail and posts
with horizontal wire infill at 4" o.c.T.O. Rail: 14.40'
FS: 10.90'
EL: 14.40'
(E) Bulkhead
(N) Cantilevered Bulkhead
extenstion
Scale: 1/4" = 1'-0"
DATE ISSUE/REVISION REVIEW
DRAWING DESCRIPTION
PROJECT
All drawings and written material appearingherein constitute original and unpublishedwork of the architect and may not beduplicated, used or disclosed without thewritten consent of Laidlaw Schultz Architects.
3111 Second AvenueCorona del Mar, CA 92625-2322(949) 645-9982 Fax: (949) 645-9554
www.LSarchitects.com
SHEET NO.
Elevations
1 South Elevation (Right)
3 Material Schedule
Scale: 1/4" = 1'-0"2 East Elevation (Bulkhead Railing)
9'
-
1
0
"
6'
-
0
"
10
'
-
1
0
"
8'
-
9
"
1'
-
4
"
9'
-
6
"
Ex
i
s
t
i
n
g
5'
-
1
1
"
5'
-
1
1
"
3'-
0
"
20
'
-
6
"
26
'
-
0
"
Max. HeightEL: 36.80'
(E) Second Floor
EL: 22.65'
Garage Floor(E)EL: 9.90'
First FloorEL: 10.90'
2nd Floor Top PlateEL: 31.40'
203
Bedroom
100
Garage
104
Dining Room
108
Kitchen
207
Study/Gym
210
M. Bed
3'
-
6
"
m
i
n
.
10
'
-
1
"
8'
-
9
"
11
'
-
3
"
10
'
-
1
"
8'
-
9
"
8'
-
9
"
1'
-
4
"
3'
-
6
"
m
i
n
.
10
'
-
6
"
3'
-
6
"
Max. HeightEL: 36.80'
(E) Second Floor
EL: 22.65'
Garage Floor(E)EL: 9.90'
First FloorEL: 10.90'
2nd Floor Top PlateEL: 31.40'
20
'
-
6
"
25
'
-
1
1
"
⅊
(E) Bulkhead and Tie back
to remain
(N) Cantilevered Bulkhead
extenstion
3'
-
6
"
m
i
n
.
Dashed line indicatesFuture bulkhead for Design
Adaptability elevationNAVD88 TW: 14.40'
TO Slab: 10.00'
FS: 10.90'
New Bulkhead Guardrail, +42"above FS. Steel top rail and posts
with horizontal wire infill at 4" o.c.T.O. Rail: 14.40'
208
Master Closet
105
Back Kitchen
106
Pantry
107
Foyer9'
-
6
"
3'
-
6
"
m
i
n
.
8'
-
9
"
4'
-
4
"
8'
-
9
"
1'
-
4
"
Max. HeightEL: 36.80'
(E) Second Floor
EL: 22.65'
Garage Floor(E)EL: 9.90'
First FloorEL: 10.90'
2nd Floor Top PlateEL: 31.40'
Scale: 1/4" = 1'-0"1
DATE ISSUE/REVISION REVIEW
DRAWING DESCRIPTION
PROJECT
All drawings and written material appearingherein constitute original and unpublishedwork of the architect and may not beduplicated, used or disclosed without thewritten consent of Laidlaw Schultz Architects.
3111 Second AvenueCorona del Mar, CA 92625-2322(949) 645-9982 Fax: (949) 645-9554
www.LSarchitects.com
SHEET NO.
Sections
Scale: 1/4" = 1'-0"3
Section
Section
2 Section
Scale: 1/4" = 1'-0"
FX4G
G
Wa
s
h
.
Dr
y
.
GF
I
+
4
2
"
+4
2
"
GF
I
Fr
z
.
Re
f
.
DWGD
DW GD
OvenG GFI +42"
Re
f
.
Ic
e
GFIWP
GFIWP
GFI GFI
GFI
GF
I
GF
I
EV
GD
C TV
GFI +42"GFI +42"
GF
I
+
4
2
"
GFI +42"
100
Garage
102
Powder
103
Laundry
104
Dining Room
107
Foyer
109
Living Room
108
Kitchen
105
Back Kitchen
106
Pantry
9'-6"
10'-6"
10'-6"
10'-6"
9'-6"
10'-6"
9'-0"
9'-0"
9'-0"
9'-10"
9'-10"
9'-6"
9'-0"
KP
VS
3
3
3
3
3
VS
3
VS
3
3
3
3
3
3
3
3
333
3
3
3
ToAbove
58" Type 'X'GWBRe: 11/A.700
HV
F5
F5
F5 F5
F4 F4 F4 F4
FX1
FX1
FX1
FX1
F6
F6 F6
F6
F6F6
F6
F6 F1
F1 F1F1F1
F1
F1 F2
F1
F1 F1 F1
F1 F1 F1
F1 F1 F1
F2 F2 F2
F1F1F1F1
F1
F1F1F1F1
F1
F1 F1 F1
F1 F1
F1
FX1
FX1 FX1 FX1 FX1 FX1 FX1
FX3 FX3
FX3FX3FX3
F5F5
F1
G
GF
I
F7
F7
F1
3
EF
FX2
General Notes:
1. All ceilings to be as heights noted on reflected ceiling
plan AFF U.N.O.
2. Elec. outlets, thermostats, light switches, etc. to align
vertically, UNO. Refer to interior elev. for furtherclarification. Elec. outlets to be w/in wood base, UNO.
3. Electrical subcontractor to submit for Architect's
approval shop drawings for lighting, switching and lifesafety locations. Provide on background which reflects
all ceiling elements which need to coordinate inlocation.
4. HVAC subcontractor to submit for Architect's approval
shop drawings which include all supply, return, andthermostat locations. Provide on background which
reflects all ceiling elements which need to coordinatein location.
5. Sprinkler subcontractor to submit for Architect's
approval shop drawings for sprinkler head locations.
Provide on background which reflects all ceilingelements which need to coordinate in location.
6. Contractor to notify the Architect before installation of
any specified lighting fixtures, devices and HVACregisters that have conflicts.
7. All continuous fixtures are to be installed end to end to
prevent any dark spots and sized to fill opening.Subcontractor to verify engineer's quantity.
8. Sprinklers to have concealed heads with flush cover
plates. Cover plates to match adjacent ceiling finish.
9. Architectural plan shall rule over engineered drawings
or specification regarding placement of all fixtures and
devices.
10. Areas of drywall ceiling are to be coordinated so that
access panels are not required. Elements requiringaccess should be located to areas of accessible
ceiling. Coordinate with Architect.
11. Electrical Contractor to adjust all lighting w/ Architectin field prior to move in.
12. Lights to be equally spaced and centered within
space, UNO. G.C. to provide chalk layout of electrical& lighting prior to construction and arrange a field
meeting for lighting layout review w/ Architect, owner& lighting consultant prior to any electrical fixture
installation.
13. General contractor to coordinate w/ owner's speakersystem subcontractor and security system
subcontractor.
14. Provide IC rated can @ all fixtures that come incontact w/ insulation.
15. At fluorescent fixtures, provide 3500K temperature bulb
(to match incandescent)
16. Provide smallest diameter can.
17. Garage, laundry rooms, and utility rooms shall be high
efficacy luminaires AND controlled by an occupancysensor.
18. All recessed light fixtures mounted in unconditionedspace must be air-tight and IC approved. During
installation the fixture must be sealed or gasketed toprevent leakage around fixture into the unconditioned
space, i.e. attic, joist or rafter space.
19. All lighting control devices, ballasts and luminaires tocomply with Sec. 119 of CEC 2013.
20. Exterior lighting mounted on the building to be high
efficacy or controlled by photo control/motion sensorcombinations with no override/bypass switch.
21. Lighting in all bedrooms, hall, living room, den and
other similar rooms to be high efficacy or shall becontrolled by manual "ON" occupant sensor or
dimmer.
22. Permanent lighting integral to cabinetry shall belimited to 20 watts of power per linear foot of
illuminated cabinet.
23. Kitchens: 50% of the total wattage for kitchen lightingto be high efficacy (e.g. fluorescent).
24. Re: T-24 for Title 24 Energy Requirements.
25. All permanently installed high efficiency luminaires
shall be switched separately from low efficiencyluminaires.
26. Lighting integral with exhaust fans, in rooms other thankitchens, is to comply with lighting efficiency
requirements per mandatory features list.
27. All stairways shall have an illumination level on treadruns of not less than 1 foot candle (11 lux) per CBC
1205.4.
EF - Flush recessed exhaust fan exhausting to the outside.Ductless fans are unacceptable. Must be
ENERGYSTAR compliant and equipped with
humidistat controls capable of adjustment betweenrelative humidity ranges of <50% to a maximum of
80% when not parts of a whole house ventilationsystem. 50 cfm min, 100 cfm for Master Bath
HF - Hood fan integrated into professional range hood w/light to provide 100cfm min exhaust to exterior with
humidistat control.
WH - Whole-house ventilation fan to be operatingcontinuously
F1 - High efficacy recessed downlight, dimmable
F2 - High efficacy adjustable directional downlight,
dimmable
F3 - High efficacy recessed downlight, approved for wetlocations.
F4 - Pendant light
F5 - High efficacy continuous LED strip light.
F6 - 1' x 4' Rectangular Surface mounted fluorescent
F7 - High efficacy wall-mounted sconce
F8 - High efficacy recessed spot downlight
FX1 - Exterior high efficacy recessed downlight, to beshielded
FX2 - Exterior high efficacy wall-mounted downlight, to beshielded
FX3 - Exterior high efficacy surface-mounted downlight, tobe shielded
FX4 - Exterior high efficacy Pendant light
KP - Garage Door Keypad
-Electric vehicle supply equipment per CEC,Article 625
- Outlet in drawer to be in 2nd drawer UNO
-Switch at 44" AFF, UNO
-Three Way Switch at 44" AFF, UNO
-Dimmer Switch at 44" AFF, UNO
-Three Way Dimmer Switch at 44" AFF, UNO
-Motion sensor or photocontrol without switchfor exterior lighting
-Garage Door Switch
EVSE
3
3
Drw
-Combination smoke detector (UL 217 Rated)carbon monoxide alarm (UL 2034/2075 Rated):Shall sound an alarm audible in all areas of thebuilding. Detectors in bedrooms to be onArc_fault circuit interrupter. Carbon monoxideshall be UL 2034/2075 rated. Alarms may bebattery operated but not interconnected.
ARCi - Indicates fixture to be on ARC_fault circuit
interrupter
S
Whole-Building Ventilation Summary
1. A whole-building ventilation system shall be installed in accordance with
ASHRAE 62.2 for new buildings and revisions greater or equal to 1000 sq. ft.
2. Covers or louvers for the whole house exhaust fan shall have a minimuminsulation value of R-4.2
3. Labeling Documentation - Controls for continuously-running fans to bemarked "Fan to be on for indoor air quality". Installer to complete
CF-6R-MECH 05. Certifying ventilation system meets ASHRAE 62.2 standards.
-Half hot floor outlet
-Fourplex electrical outlet
-Duplex electrical outlet
-Outlet with ground fault circuit interrupter
-Duplex electrical outlet located in toe kick
-Half hot electrical floor outlet outlet
-Outlet w/ waterproof cover
GFI
WP
TK
-Manual "on" vacancy detector switch. Wallmount, w/ three-way and dimmer whereoccurs.
-Garage Door Opener, provide power
-Hose Bib. Must be protected by an anti siphondevice
-Gas
-Coaxial Cable
-Telephone and data outlet
-Junction Box
VS
GD
HB
G
C
J
Scale: 1/4" = 1'-0"
Fixture Schedule / Legend General Notes32
DATE ISSUE/REVISION REVIEW
DRAWING DESCRIPTION
PROJECT
All drawings and written material appearingherein constitute original and unpublishedwork of the architect and may not beduplicated, used or disclosed without thewritten consent of Laidlaw Schultz Architects.
3111 Second AvenueCorona del Mar, CA 92625-2322(949) 645-9982 Fax: (949) 645-9554
www.LSarchitects.com
SHEET NO.
Reflected Ceiling Plans
General Notes:
1. All ceilings to be as heights noted on reflected ceiling
plan AFF U.N.O.
2. Elec. outlets, thermostats, light switches, etc. to align
vertically, UNO. Refer to interior elev. for furtherclarification. Elec. outlets to be w/in wood base, UNO.
3. Electrical subcontractor to submit for Architect's
approval shop drawings for lighting, switching and lifesafety locations. Provide on background which reflects
all ceiling elements which need to coordinate inlocation.
4. HVAC subcontractor to submit for Architect's approval
shop drawings which include all supply, return, andthermostat locations. Provide on background which
reflects all ceiling elements which need to coordinatein location.
5. Sprinkler subcontractor to submit for Architect's
approval shop drawings for sprinkler head locations.
Provide on background which reflects all ceilingelements which need to coordinate in location.
6. Contractor to notify the Architect before installation of
any specified lighting fixtures, devices and HVACregisters that have conflicts.
7. All continuous fixtures are to be installed end to end to
prevent any dark spots and sized to fill opening.Subcontractor to verify engineer's quantity.
8. Sprinklers to have concealed heads with flush cover
plates. Cover plates to match adjacent ceiling finish.
9. Architectural plan shall rule over engineered drawings
or specification regarding placement of all fixtures and
devices.
10. Areas of drywall ceiling are to be coordinated so that
access panels are not required. Elements requiringaccess should be located to areas of accessible
ceiling. Coordinate with Architect.
11. Electrical Contractor to adjust all lighting w/ Architectin field prior to move in.
12. Lights to be equally spaced and centered within
space, UNO. G.C. to provide chalk layout of electrical& lighting prior to construction and arrange a field
meeting for lighting layout review w/ Architect, owner& lighting consultant prior to any electrical fixture
installation.
13. General contractor to coordinate w/ owner's speakersystem subcontractor and security system
subcontractor.
14. Provide IC rated can @ all fixtures that come incontact w/ insulation.
15. At fluorescent fixtures, provide 3500K temperature bulb
(to match incandescent)
16. Provide smallest diameter can.
17. Garage, laundry rooms, and utility rooms shall be high
efficacy luminaires AND controlled by an occupancysensor.
18. All recessed light fixtures mounted in unconditionedspace must be air-tight and IC approved. During
installation the fixture must be sealed or gasketed toprevent leakage around fixture into the unconditioned
space, i.e. attic, joist or rafter space.
19. All lighting control devices, ballasts and luminaires tocomply with Sec. 119 of CEC 2013.
20. Exterior lighting mounted on the building to be high
efficacy or controlled by photo control/motion sensorcombinations with no override/bypass switch.
21. Lighting in all bedrooms, hall, living room, den and
other similar rooms to be high efficacy or shall becontrolled by manual "ON" occupant sensor or
dimmer.
22. Permanent lighting integral to cabinetry shall belimited to 20 watts of power per linear foot of
illuminated cabinet.
23. Kitchens: 50% of the total wattage for kitchen lightingto be high efficacy (e.g. fluorescent).
24. Re: T-24 for Title 24 Energy Requirements.
25. All permanently installed high efficiency luminaires
shall be switched separately from low efficiencyluminaires.
26. Lighting integral with exhaust fans, in rooms other thankitchens, is to comply with lighting efficiency
requirements per mandatory features list.
27. All stairways shall have an illumination level on treadruns of not less than 1 foot candle (11 lux) per CBC
1205.4.
EF - Flush recessed exhaust fan exhausting to the outside.Ductless fans are unacceptable. Must be
ENERGYSTAR compliant and equipped with
humidistat controls capable of adjustment betweenrelative humidity ranges of <50% to a maximum of
80% when not parts of a whole house ventilationsystem. 50 cfm min, 100 cfm for Master Bath
HF - Hood fan integrated into professional range hood w/light to provide 100cfm min exhaust to exterior with
humidistat control.
WH - Whole-house ventilation fan to be operatingcontinuously
F1 - High efficacy recessed downlight, dimmable
F2 - High efficacy adjustable directional downlight,
dimmable
F3 - High efficacy recessed downlight, approved for wetlocations.
F4 - Pendant light
F5 - High efficacy continuous LED strip light.
F6 - 1' x 4' Rectangular Surface mounted fluorescent
F7 - High efficacy wall-mounted sconce
F8 - High efficacy recessed spot downlight
FX1 - Exterior high efficacy recessed downlight, to beshielded
FX2 - Exterior high efficacy wall-mounted downlight, to beshielded
FX3 - Exterior high efficacy surface-mounted downlight, tobe shielded
FX4 - Exterior high efficacy Pendant light
KP - Garage Door Keypad
-Electric vehicle supply equipment per CEC,Article 625
- Outlet in drawer to be in 2nd drawer UNO
-Switch at 44" AFF, UNO
-Three Way Switch at 44" AFF, UNO
-Dimmer Switch at 44" AFF, UNO
-Three Way Dimmer Switch at 44" AFF, UNO
-Motion sensor or photocontrol without switchfor exterior lighting
-Garage Door Switch
EVSE
3
3
Drw
-Combination smoke detector (UL 217 Rated)carbon monoxide alarm (UL 2034/2075 Rated):Shall sound an alarm audible in all areas of thebuilding. Detectors in bedrooms to be onArc_fault circuit interrupter. Carbon monoxideshall be UL 2034/2075 rated. Alarms may bebattery operated but not interconnected.
ARCi - Indicates fixture to be on ARC_fault circuit
interrupter
S
Whole-Building Ventilation Summary
1. A whole-building ventilation system shall be installed in accordance with
ASHRAE 62.2 for new buildings and revisions greater or equal to 1000 sq. ft.
2. Covers or louvers for the whole house exhaust fan shall have a minimuminsulation value of R-4.2
3. Labeling Documentation - Controls for continuously-running fans to bemarked "Fan to be on for indoor air quality". Installer to complete
CF-6R-MECH 05. Certifying ventilation system meets ASHRAE 62.2 standards.
-Half hot floor outlet
-Fourplex electrical outlet
-Duplex electrical outlet
-Outlet with ground fault circuit interrupter
-Duplex electrical outlet located in toe kick
-Half hot electrical floor outlet outlet
-Outlet w/ waterproof cover
GFI
WP
TK
-Manual "on" vacancy detector switch. Wallmount, w/ three-way and dimmer whereoccurs.
-Garage Door Opener, provide power
-Hose Bib. Must be protected by an anti siphondevice
-Gas
-Coaxial Cable
-Telephone and data outlet
-Junction Box
VS
GD
HB
G
C
J
EF
EF
EF
EF
+42"GFI
+4
2
"
GF
I
+42"GFI
+42"GFI
G
GF
I
WP
GFIWP
GFIWP
GFIWP
200
Bedroom
203
Bedroom
201
Bath
202
Closet
204
Closet
206
Linen
205
Bath
207
Study/Gym
208
Master Closet
210
Master Bed
209
Master Bath
10'-0"
10'-0"
8'-9"
8'-9"
8'-0"8'-9"
21'-10"
10'-0"
8'-9"
3
ToAbove
VS
VS
VS
3 3
VS
VS
3
3
3
3
3
3
8'-0"
8'-9"
8'-0"
8'-9"
8'-9"
10'-0"
10'-0"
8'-0"
10'-0"10'-0"10'-0"10'-0"10'-0"
F5
F5
F5
F5 F5
F5F5
F5
FX1
FX1
FX1
FX1
FX1
F1 F1
F1F1
F1 F1
F7F7 F7F7
F1 F3
F3
F1
F7
F7
F7 F7
F7 F7F1
F1
F1F1
F1
F1
F7 F7
F1
F1 F1
F1
F1 F1
F1
F1 F1 F1
F1F1F1
F1 F1 F1
F1F1F1F1F1F1F1
F1
F1
F1 F1 F1
F1F1F1
F1 F1 F1
F7F7
F2 F2F2F1
F1
F1F1
F1
F1 F1 F1
F1
F1 F3F1
WH
℄
Bay
℄Bay
℄Bay
℄Bay
℄Bay
℄
Bay
℄
Bay
℄Bay
℄Bay
℄Bay
℄Bay
℄Bay
FX2
3
3
GF
I
WP
Scale: 1/4" = 1'-0"
Reflected Ceiling Plans
3
DATE ISSUE/REVISION REVIEW
DRAWING DESCRIPTION
PROJECT
All drawings and written material appearingherein constitute original and unpublishedwork of the architect and may not beduplicated, used or disclosed without thewritten consent of Laidlaw Schultz Architects.
3111 Second AvenueCorona del Mar, CA 92625-2322(949) 645-9982 Fax: (949) 645-9554
www.LSarchitects.com
SHEET NO.
Fixture Schedule / Legend General Notes2
FX1 - Exterior high efficacy recessed downlight, to beshielded
FX2 - Exterior high efficacy wall-mounted downlight, to beshielded
FX3 - Exterior high efficacy surface-mounted downlight, to
be shielded
FX4 - Exterior high efficacy Pendant light
Exterior Lighting Specs
DATE ISSUE/REVISION REVIEW
DRAWING DESCRIPTION
PROJECT
All drawings and written material appearingherein constitute original and unpublishedwork of the architect and may not beduplicated, used or disclosed without thewritten consent of Laidlaw Schultz Architects.
3111 Second AvenueCorona del Mar, CA 92625-2322(949) 645-9982 Fax: (949) 645-9554
www.LSarchitects.com
SHEET NO.
Fixture Schedule / Legend FX3FX2
ZW ZD 1LED DN CU
FX1
Base @ Stucco Scale: 3" = 1'-0"14710
811
36912
1. All metal flsh'g joints to be fully soldered & sealed.
2. Dissimilar metal types subject to electrolytic reaction to be physically separated.
3. Guardrails: Refer to shop drawings by others for all attachments and connections. Top
rail to resist a single concentrated load of 200 lbs., applied in any direction at any pointalong the top, and have attachment devices and supporting structure to transfer this
loading to appropriate structural elements of the building per 1607.7.1 and 1607.7.1.1.
4. Exposed metal members & fasteners to be primed and painted unless noted otherwise.
5. Conceal all fasteners, UNO
6. All exposed welds shall be full fillet and ground smooth
7. All exposed wood shall be S4S Douglas Fir or equal, suitable for exterior use, weatherresistant, insect resistant, and back primed.
8. All exterior deck, planter framing, and wood fram'g anchored directly to concrete walls
and slabs to be Pressure Treated Douglas Fir or equal.
9. All stairways shall have an illumination level on tread runs of not less than 1 foot candle(11 lux). CBC 1205.4
10. Provide paintable high performance sealant at all exposed structural member joints
and intersections with other building components.
11. All Window/ Door/ Skylight flashing to meet or exceed ASTM E 2112-01
General Notes
J Metal - No. 26 gauge Galv.Corrosion Resistant Weep Screed
Interior baseboard
Batt insulation w/ 2xFraming per struct., typ.
Plywood sheathing
58" GWB, typ.
7/8" Exterior Plaster
3"
M
i
n
.
T
y
p
.
At
H
a
r
d
S
u
r
f
a
c
e
4"
T
y
p
.
@
g
r
a
d
e
.
8"
M
i
n
.
T
y
p
.
At
F
i
n
.
G
r
a
d
e
SL
2"
T
y
p
.
@
ha
r
d
su
r
f
a
c
e
1% @ Conc.
2% @ Grade
Finish grade
Electrical outlet Re: A.500
WRB
Galv. Mtl. Drip Flashing
Stucco Finish Coat
Self-furring wire lathe
Line of Raised Conc. curb,
where occurs.
714"
114"
12"14"
Firestone UNA-CLAD Standing SeamMetal Roofing; ICC ESR - 3422
Roof sheathing Re: Structural
Air-impermeable spray-in
foam insulation. Re: Title 24
*Note - Assembly to comply
with R806.5: Unvented attic
& unvented enclosed rafter.Re: Roof Notes A.204
Firestone CLAD-GARD
underlayment; underlayment lapover cleat. ICC ESR -3464.
1/4" DensDeck Roof Board by
Georgia-Pacific
4" min.
SL per
P
l
a
n
Ridge Cap
Roof panel receiver
Roof Ridge Scale: 3 " = 1'-0"
Ridge Beam per Structural
Scale: 3 " = 1'-0"
1'-6" each
s
i
d
e6"
*Note: Sections of flashing shall have an end lap of not less than 4"
SECURE VALLEY FLASHING WITHCLIPS. NO PENETRATIONS INTO
VALLEY FLASHING. SMACNA Std.
36" Wide felt valley stripover roof sheathing
Cont. clip
Valley Flashing
Firestone UNA-CLAD Standing SeamMetal Roofing; ICC ESR - 3422
Firestone CLAD-GARDunderlayment; underlayment lapover cleat. ICC ESR -3464.
1/4" DensDeck Roof Board by
Georgia-Pacific o/ RoofSheathing Re: Structural
SL per
P
l
a
n
Roof Valley
Corrosion resistant metal weepscreed w/ 1/2" dia. weep holes
at 6' OC or per code reqm'twhere more stringent
Interior baseboard
Batt insulation w/ 2xFraming per struct., typ.
Plywood sheathing
58" GWB, typ.
Mountain Valley Blend Veneer(Modern Builders Supply)
3"
M
i
n
.
T
y
p
.
At
H
a
r
d
S
u
r
f
a
c
e
4"
T
y
p
.
@
g
r
a
d
e
.
8"
M
i
n
.
T
y
p
.
At
F
i
n
.
G
r
a
d
e
SL
2"
T
y
p
.
@
ha
r
d
su
r
f
a
c
e
1% @ Conc.
2% @ Grade
Finish grade
Tooled Grout Joints Typ.
Exterior Plaster, Brown and Scratch
Coat o/self furring wire lathe o/
(2)layers of type 'D' building paper.
714"
114"
12"14"
Electrical outlet Re: A.500
Base @ Stone Veneer Scale: 3" = 1'-0"
J Metal - No. 26 gauge Galv.Corrosion Resistant Weep Screed
Interior baseboard
Batt insulation w/ 2x Framing
per struct., typ.
Plywood sheathing
58" GWB, typ.
10" Horizontal Stained Circular SawnWood Siding
(Montana Timber Products)
3"
M
i
n
.
T
y
p
.
At
H
a
r
d
S
u
r
f
a
c
e
4"
T
y
p
.
@
g
r
a
d
e
.
8"
M
i
n
.
T
y
p
.
At
F
i
n
.
G
r
a
d
e
SL
2"
T
y
p
.
@
ha
r
d
su
r
f
a
c
e
1% @ Conc.
2% @ Grade
Finish grade
Electrical outlet Re: A.500
Galv. Mtl. Drip Flashing
714"
114"
12"14"
Self Adhered WRB
Base @ Wood Siding Scale: 3" = 1'-0"
SL
20 oz Copper Cap Flashing
(2) Ply Smartflash Membrane Flashing;
Extend 12" min. horizontally onto roof membrane
Certainteed Flintlastic Mod. Bitumen Roofing; ICC ESR-1388.
Self Adhered WRB
Backer Rod and Sealant
Fluid Applied Flashing
Bituthene
Wind Cleat
Roof Framing; Re: Structural
Interlocking Ptd. Metal Panel
Fascia, to Match Roofing
Scale: 3 " = 1'-0"Flat Roof at Parapet
Scale: 3 " = 1'-0"Roof Eave/Gutter, Typ.
SL per Plan
2% SL
Varies
16 oz Natural Copper Standing seam roofing, 1.5" rib, 16" o.c.
CertainTeed MetaLayment 60 mil. underlayment. ICC ESR -1492.
Roof sheathing Re: Structural
Copper square gutter & downspout
Continuous cleat, nail 6" OC
Interlocking Copper Panel Fascia, to Match Roofing
2 x Wd. T&G soffit - ptd. o/ Bldg paper
Scheduled Window
2x DF Tongue and Groove
Wood trim - Ptd.
Bituthene
Edge Flashing - to Match Roof Color
Cont. clip
2"
3" dia. drainline per Ch. 11 CPC,
Connect to internal downspouts.
Overflow & area drains to be piped separately. Tie all overflow lines together where feasible,outlet to daylight at front entry per Civil drawings. Coordinate final daylighting w/ Architect
prior to installation. Use custom scupper detail
OverflowArea
316 Marine Grade S.S. steel flange Combinationarea & overflow by Thunderbird products
316 Marine Grade S.S. snap-in grate
Scheduled paver o/ pedestal, where occurs
Dex-O-Tex Neobond Fracture Resistant Membrane or Scheduled Roofing
SL 2% min.
Scale: 112" = 1'-0"Area and Overflow Drain
Details
DATE ISSUE/REVISION REVIEW
DRAWING DESCRIPTION
PROJECT
All drawings and written material appearingherein constitute original and unpublishedwork of the architect and may not beduplicated, used or disclosed without thewritten consent of Laidlaw Schultz Architects.
3111 Second AvenueCorona del Mar, CA 92625-2322(949) 645-9982 Fax: (949) 645-9554www.LSarchitects.com
SHEET NO.
912
10 Scale: NTS
Refer to 10/A.701 Axonometric for detail requirements. All WRB, flashing components, assembly andtechnical requirement to comply with Vapro Shield details, and window mnft requirements.
Typ. Window Sill
Typ. Window Head
1
2
Window Sill @ Stone Veneer4
5 Window Head @ Stone Veneer
Scale: 3" = 1'-0"Scale: 3" = 1'-0"
Scale: 3" = 1'-0"Scale: 3" = 1'-0"
36
Refer to 10/A.701 Axonometric for detail requirements. All WRB, flashing components, assembly andtechnical requirement to comply with Vapro Shield details, and window mnft requirements.
Scale: 3" = 1'-0"Scale: 3" = 1'-0"
Refer to 10/A.701 Axonometric for detail requirements. All WRB, flashing components, assembly andtechnical requirement to comply with Vapro Shield details, and window mnft requirements.
Window per schedule
Window casing beyond
58" GWB, typ.
Batt insulation per Energy Calcs.
2x framing per plan
Shim as req'd
Copper sill pan flsh'gprovide bituthene below
sill pan
Self-adheared flashing
Fluid applied flashing
Sheathing, as req.
WRB
Ptd. wood casing
Window per schedule
Shim as req'd
Sealant & backer rod
Sheathing, as req.
Header per Struct.
Self-adheared flashing
Fluid applied flashing
58" GWB, typ.
WRB
Batt insulation per Energy Calcs.
Window per schedule
Window casing beyond
58" GWB, typ.
Batt insulation per Energy Calcs.
2x framing per plan
Shim as req'd
Copper sill pan flsh'gprovide bituthene below
sill pan
Self-adheared flashing
Fluid applied flashing
Sheathing, as req.
WRB
Ptd. wood casing
2"
112"
Stone Veneer,
See 4/A.700 for assembly
Copper Drip Flashing
Pre-cast stone sill o/ settingbed slope to drain
Window per schedule
Shim as req'd
Sealant & backer rod
Stone Veneer,
See 4/A.700 for assembly
Sheathing, as req.
Header per Struct.
Self-adheared flashing
Fluid applied flashing
WRB
Batt insulation per Energy Calcs.
Copper Drip Flashing
58" Type 'X' GWB, typ.
7/8" Exterior Plaster,See 1/A.700 for assembly
7/8" Exterior Plaster,
See 1/A.700 for assembly
Refer to 10/A.701 Axonometric for detail requirements. All WRB, flashing components, assembly andtechnical requirement to comply with Vapro Shield details, and window mnft requirements.
Refer to 10/A.701 Axonometric for detail requirements. All WRB, flashing components, assembly andtechnical requirement to comply with Vapro Shield details, and window mnft requirements.
Typical Multislide Sill Typical Multislide Head
2% SL2% SL
Scheduled floor finish
Scheduled multi-slide door
Scheduled Paver
o/ setting bed
Dex-O-Tex Elastomericwaterproof membrane,
ICC ESR-1757. Lap o/ pan
Sill pan per mnft.
Bituthene - Extend
waterproofing 24"past threshold
Header per Struct.
Self-adheared flashing
Fluid applied flashing
Scheduled multi-slidedoor
Shim as req'd
Sealant & backer rod
J- Metal
Finish per Elevations
Self-furring wire lathe
Sheathing, as req.
58" GWB, typ.
WRB
Batt insulation per Energy Calcs.
812
7
Details
DATE ISSUE/REVISION REVIEW
DRAWING DESCRIPTION
PROJECT
All drawings and written material appearingherein constitute original and unpublishedwork of the architect and may not beduplicated, used or disclosed without thewritten consent of Laidlaw Schultz Architects.
3111 Second AvenueCorona del Mar, CA 92625-2322(949) 645-9982 Fax: (949) 645-9554www.LSarchitects.com
SHEET NO.
58" Ptd. gypsum board
Typ. Flashing @ Window Opening 14128NTS
5 2
711
Scale: 3 " = 1'-0"
Scale: 112" " = 1'-0"
Scale: 3 " = 1'-0"
Scale: 3 " = 1'-0"
Scale: 3 " = 1'-0"
Scale: 3 " = 1'-0"
Scale: 112" = 1'-0"
Scale: 3 " = 1'-0"
10Window Pan Flashing Axo
0. Sheathing in "as new" condition
1. Self adhered sill piece applied directly tosheathing + installed 2.75" inside of RO.
Release film to be left on bottom 6" of flashing
to create shingle effect with field membrane
2. Self adhered jamb pieces applied directly
to sheathing at edge of rough opening andouter edge + installed 2.75" inside of RO.
3. Self adhered head piece applied directly
to sheathing at edge of rough opening andtop edge + installed 2.75" inside of RO.
4. Fluid applied flashing @ inside rough
opening + 1" on face
5. Sill pan refer to 6/A.701. Embed sill pan
onto fluid applied flashing. Tool reverse laps
and back dam.
6. Sealant beneath sill pan down turned leg
onto WRB
7. Continuous 38" continuous bead of sealantbehind window flange at head, left, and right
jambs. Provide intermittent U shims at sillflange for drainage
8. Window with nailing flange. Provide interior
sealant joint around entire perimeter ofwindow for proper air barrier continuity and
water holdout
9. Head flashing (2 Piece Painted Copper
Flashing w/ Hemmed Drip Edge) over fluidapplied flashing embedded in sealant
10. WRB shingled under sill pan and sill
flashing. WRB to be shingled over headflashing and applied in a weatherboard
fashion typical elsewhere per manufacturer'srequirements.
11. Expose sill flange to allow drainage from
pan. Provide U-shaped shims behind sill nailflange to assure drainage.
Note:Installation depicts VaproShield proprietary
system. Coordinate final assemblage with
manufacturer specific requirements:
WRB - per wall types (self adhered) byVaproShield
Self adhered flashing - VaproFlashing SAFluid applied flashing - VaproLiqui-Flash
Sealant - VaproBond Sealant
NOTE:Re: 12/A.701 for Sill Pan Detail.
- Shim and Adjust Window to AchieveSquare, Plumb, and Level Condition
- Use Corrosion Resistant Fasteners- After Window Installation, Seal All
Corners of Mechanically JoinedFrames to Seal Frame Seam Juncture.
- Install per ASTM E2112-01 and/orWRB/Flashing manufacturer
warranted criteria. Coordinatewindow installation and flashing w/
window manufacturer's requirementsand installation notation
- Provide backerod and sealant at
backside of window to prevent airand water infiltration. At jamb and
head closed cell spray in insulationcan be substituted for sealant.
- Bring to architects attention if anydetailing is in conflict with ASTM
standards and/or illustrated detail
wrb wrb
wrb
wrb
wrb
wrb
8
4
2
9
3
2
0
1
7
5
6
1011
Run Flashing up under Window Sill
and fold up 12" Minimum
4"
4"
Note: No Penetrations at horizontal portion of flashing. Where penetrationsare required, pre-drill pilot hole, apply sealant, fasten with screw, and finally
apply sealant over screw. Separate all dissimilar metals with bitument.
Match
Sill De
p
t
h
16oz Copper Metal
Flashing Full Solder allJoints Typ. Set in Mastic
Sill Pan to follow SMACNA standards
Slope
t
o
d
r
a
i
n
4"
4"
13
14
Run ElastomericMembrane Up Curb and
Under Threshold toInterior Edge of Flashing,
Where Applicable
1
1
/
2
"
3 1/2"
6"
2"
6"
4"
Sill Pan
Line of Finished HardSurface L Metal
At Plaster Systems Provide
Weep Screed/Plaster Stop w/Weep Holes @ 24" o.c. or as
Req. by Code
16 oz. CopperFlashing
Building Flashing
Cont. Solder Joint, Typ.
Note: Full Solder all Joints
Provide one layer ofBituthene below sill pan
Sill Pan to follow SMACNA standards
Slope
t
o
d
r
a
i
n
Door Pan Flashing Axo
GA FILE NO. RC 2601
GYPSUM WALLBOARD, WOOD JOISTS, ROOF COVERING
Base layer 5/8" type X gypsum wallboard applied at right angles to 2 x 10wood joists 24" o.c. with 114" Type W or S drywall screws 24" o.c. Face layer 5/8"type X gypsum wallboard or gypsum veneer base applied at right angles tojoists with 178" Type W or S drywall screws 12" o.c. at joints and intermediatejoists and112" Type G drywall screws 12" o.c. placed 2" back on either side ofend joints. Joints offset 24" from base layer joints. Wood joists supporting 12"plywood with exterior glue applied at right angles to joists with 8d nails.Appropriate roof covering. Ceiling provides one hour fire resistance protectionfor framing, including trusses.
1-Hour FireGeneric
Note: Greater stud sizes (depths) shall be permitted to be used in metal- or
wood-stud systems. Indicated stud spacings are maximums.
Approx. Ceiling
Weight: 5 psf
Fire Test: FM FC 172, 2-25-72; ITS, 8-6-98
1 Hr. Ceiling Assembly @ Garage
GA FILE NO. RC 3661 Generic 1-Hour Fire
GYPSUM WALLBOARD, WOOD STUDS, MINERALFIBER INSULATION
58" type 'X' GWB w/ final finish per interiorelevations. Applied at right angles to each
side of framing with 214" Type S or W drywall
screws 12" o.c. Vertical joints staggered 16"o.c., horizontal joints staggered 24" o.c., on
opposite sides.
Min. R-15 batt insulation, nominal 2.5 pcf
friction fit in stud space
Int.Int.
312"
Thickness: 4
34"Approx. Weight: 7.5 psf
Fire Test: ITS J20-06170.1, 4-00
First Floor - 2x4 LSL, 16" o.c.Second Floor - 2x4
conventional framing, 16" o.c.
1 Hr. Wall Assembly @ Garage
1" Typ.
10" Min. RunSee Plan
7
3
/
4
"
M
a
x
.
Ri
s
e
Se
e
P
l
a
n
Stone Stair tread
Thin set mortar
Stone paving
Stone riser
Expansion joint,
silicone caulk tomatch mortar
Conc. Slab & Stair
per struct.
Typ. Ext. Stair on grade Scale: 3 " = 1'-0"4
Self Adhered/ WRB Barrier
placed under Flashing inweatherboard fashion
38"
SL 2%
Scheduled pedestal
paver system
7/8" Exterior Plaster o/self-furring wire lathe
58" Ptd. gypsum board
Deck to Wall
6"
4"
1"
12"
234"
6
5
4
10
1
Scale: 3" = 1'-0"Window Sill Flashing
Area and Overflow Drain
Scheduled Terrazo
Tile o/ poured inplace concrete base
1"nosing
Stl. Channel Stringer
Re: Structural
Stl. Plate tread support
welded to stringer.Provide holes w/
chamfered edge tocompletely recess
fastener head.Re: Structural
Solid Wood Tread
#10 Flat head square
drive wood screw
lessthan 4"
less
than 4
"
Stair at Landing
Railing Cap
1'-0" Tread Depth
Stair at Floor
38"Ø SS Rods;must not allow passageof a 4"Ø sphere
Scale: 112" " = 1'-0"
Landing Depth
Pe
r
P
l
a
n
6
1
3
/
1
6
"
112"2 " x 114" Handrail w/ 18"Eased Edges
12" x 114" Stl Post
12" x 12" Mtl Upright
3xSolid Blocking w/ (3) 16d Each End Recessedto Allow for Steel Backing At Handrail Supports
Continuous Weld and
Grind Smooth
36
"
T
o
N
o
s
i
n
g
112"
Cl
r
(2) 12"d. x 212" Lag Bolts Ea. Plate to Blkg.
Scheduled Material
2"
114"
Edges shall have a minimum radius of 0.01 inch.Handrails shall be continuous except at a turn they are permitted to be
interrupted by a newl post and have a minimum clear distance between
the wall and handrail grip of 1 12".
2 1/4"
max
min.
Handrail Detail
9
38"Ø Stainless Steel Rods;must not allow passage
of a 4"Ø sphere
Stl. Channel Stringer
Re: Structural
Note: Aluminum must not be placed in direct contact with concrete
or dissimilar metals. Use appropriate paint, primer, or bitumen
Stl. Plate tread support
welded to stringer. Provideholes w/ chamfered edge to
completely recess fastenerhead. Re: Structural
#10 Flat head squaredrive wood screw
Solid Wood Tread
2" tab
Stair Tread beyond
1"
Stair Tread @ Stringer
34" x 112" Steel Flat BarUpright welded to
stringer
Architectural Grade
Continuous Metal Handrailw/ Wood Cap; Wood to
match tread
Pe
r
P
l
a
n
6
1
3
/
1
6
"
less
t
h
a
n
4
"
11" typ.
3"3"
36
"
a
b
v
.
S
t
a
i
r
N
o
s
i
n
g
(
N
T
S
)
3
3
/
8
"
les
s
t
h
a
n
4
"
Note: Aluminum must not be placed in direct contact with concrete
or dissimilar metals. Use appropriate paint, primer, or bitumen
42
"
a
b
v
.
F
i
n
i
s
h
S
u
r
f
a
c
e
(
N
T
S
)
les
s
t
h
a
n
4
"
Architectural Grade
Continuous Metal Handrailw/ Wood Cap; Wood to
match tread
34" x 112" Steel Flat BarUpright w/ Return
Scheduled floor finish
Continuous Weld andGrind Smooth
Guardrail
Ptd. Steel Channel BeamRe: Structural
Solid wood treadas first riser
3"
3"
Channel Stringerbeyond; To
extend andattach toconcrete
3"
2"
3" dia. drainline per Ch. 11 CPC,
Connect to internal downspouts.Overflow & area drains to be piped separately. Tie all
overflow lines together where feasible, outlet to daylight at
front entry per Civil drawings. Coordinate final daylighting w/Architect prior to installation. Use custom scupper detail
OverflowArea
316 Marine Grade S.S. steel flange Combinationarea & overflow by Thunderbird products
316 Marine Grade S.S.snap-in grate
Scheduled paver o/ pedestal, where occurs
Dex-O-Tex Neobond Fracture Resistant
Membrane or Scheduled Roofing
SL 2% min.
12
"
6"
m
i
n
.
Dex-O-Tex Neobond FractureResistant Membrane;
Re: Detail 10/A.701
6" tab
11" typ.
36
"
a
b
v
.
S
t
a
i
r
No
s
i
n
g
(
N
T
S
)
Per Plan6 13/16"
38"Ø Stainless Steel Rods;must not allow passage
of a 4"Ø sphere
15
"
12"
12"
Details
DATE ISSUE/REVISION REVIEW
DRAWING DESCRIPTION
PROJECT
All drawings and written material appearingherein constitute original and unpublishedwork of the architect and may not beduplicated, used or disclosed without thewritten consent of Laidlaw Schultz Architects.
3111 Second AvenueCorona del Mar, CA 92625-2322(949) 645-9982 Fax: (949) 645-9554www.LSarchitects.com
SHEET NO.
F.F.=10.90
T/SLAB=10.78
PAD=9.70
GARAGE PROPOSED RESIDENCE
CL
LI
N
D
A
I
S
L
E
LOT 54
TRACT NO. 4003
M.M. 188/13-19
LOT 55
LOT 53
N7
1
°
5
4
'
5
8
"
W
4
5
.
0
0
'
N18°05'02"E 124.00'
N18°05'02"E 124.00'
N7
1
°
5
4
'
5
8
"
W
4
5
.
0
0
'
LEGEND SCOPE OF WORKCITY OF NEWPORT BEACH NOTES
1 3 9 A v e n i d a N a v a r r o
S a n C l e m e n t e , C A 9 2 6 7 2
9 4 9 . 4 9 2 . 8 5 8 6
w w w . t o a l e n g i n e e r i n g . c o m
C I V I L E N G I N E E R I N G
L A N D S U R V E Y I N G
STORMWATER QUALITY
ADAM L. TOAL
R.C.E. 59275
DATE:
ADDITIONAL NOTES
EASEMENT NOTE
UTILITY NOTES
TOPOGRAPHIC SURVEY
LINDA ISLE H.O.A. NOTES
F.F.=10.90
T/SLAB=10.78
PAD=9.70
GARAGE PROPOSED RESIDENCE
PROPOSED RESIDENCE
CL
LI
N
D
A
I
S
L
E
LOT 54
TRACT NO. 4003
M.M. 188/13-19
LOT 55
LOT 53
N7
1
°
5
4
'
5
8
"
W
4
5
.
0
0
'
N18°05'02"E 124.00'
N18°05'02"E 124.00'
N7
1
°
5
4
'
5
8
"
W
4
5
.
0
0
'
YEAR-ROUND BMP REQUIREMENTS
1 3 9 A v e n i d a N a v a r r o
S a n C l e m e n t e , C A 9 2 6 7 2
9 4 9 . 4 9 2 . 8 5 8 6
w w w . t o a l e n g i n e e r i n g . c o m
C I V I L E N G I N E E R I N G
L A N D S U R V E Y I N G
STORMWATER QUALITY
ADAM L. TOAL
R.C.E. 59275
DATE:
LEGEND
NOTE
EROSION CONTROL BMPs
TEMPORARY SEDIMENT CONTROL
WIND EROSION CONTROL
TRACKING CONTROL
WASTE MANAGEMENT AND MATERIALS POLLUTION CONTROL
NON-STORMWATER MANAGEMENT
TOPOGRAPHIC SURVEY
UP
DN
DN
DN
DN
DN
2%
+
(E)TW 15.69'
+
(E)TW 11.33'
+
(E)TW 11.24'
+
(E)TW 14.95'
+
(E)TW 15.32'
+
FS 9.9'
FFE 10.9'
+
(E)TW 15.99'
+
(E)TW 15.2'
+
(E)TW 11.87'
+
(E)TW 11.7'
LI
N
D
A
I
S
L
E
D
R
I
V
E
NE
W
P
O
R
T
B
A
Y
PL
PL
PL
PL
GARAGE
FFE 10.0
PA
PA
PA
PA
PA
PAPAPA
PA
PA
2%
2%
2%
+
FS 10.9
2%
2%
2%
2%
SHEET NO
SHEET PLOTTED :
DRAFTED BY:
SCALE:
REVISIONS
KB
NE
W
P
O
R
T
B
E
A
C
H
,
C
A
L
I
F
O
R
N
I
A
MA
R
I
M
A
N
R
E
S
I
D
E
N
C
E
6/23/2023
2OF
54
L
I
N
D
A
I
S
L
E
NORTH
1/8" = 1'
0 4' 8'16'32'
18" = 1'-0"
P
R
E
L
I
M
I
N
A
R
Y
HA
R
D
S
C
A
P
E
P
L
A
N
L-1
MARIMAN RESIDENCE
HARDSCAPE LEGEND
H-1 18” HIGH CONCRETE BLOCK PLANTER WALL WITH STONE
VENEER TO MATCH ARCHITECTURE
H-2 24" x 48" x 3" LIMESTONE SLABS ON A PEDESTAL SYSTEM
WITH DRAINAGE BELOW
H-3 PORCELAIN ENTRY PAD ON A CONCRETE BASE
H-4 PORCELAIN STEPPING STONE PAVERS ON A CONCRETE
BASE
H-5 BEACH COBBLE GROUNDCOVER
H-6 18” DEEP WATER BASIN WITH SUBMERSIVE FOUNTAIN PUMP
H-7 NATURAL STONE WATER WALL TO MATCH ARCHITECTURAL
STONE VENEER
H-8 3’-0” HIGH CERAMIC CONTAINER WITH SPILLING PLANTS
H-9 4’-0” WIDE X 6’-0” HIGH WOOD GATE TO MATCH GARAGE
DOOR SIDING
H-10 NEW BRICK PAVING TO MATCH EXISTING BRICK DRIVEWAYPER H.O.A.GUIDELINES
H-11 3’-0” WIDE X 6’-0” HIGH SIDE YARD WOOD GATE TO MATCH
THE GARAGE DOOR SIDING
H-12 4” THICK COLORED CONCRETE PAVING WITH WASHED
FINISH
H-13 12” WIDE TRIANGULAR VINE POCKET
H-14 30” WIDE X 10’ LONG X 16” HIGH GAS FIRE ELEMENT WITHSTONE VENEER TO MATCH ARCHITECTURAL VENEER
H-15 16” HIGH X 30” WIDE X 9’-6” MODULAR FIBERGLASS
PLANTER WITH DRAINS TO CONNECT TO SUMP PUMP
H-16 AIR CONDITIONING UNITS
H-17 GAS FIREPLACE WITH RAISED HEARTH
H-18 18” WIDE PLANTER ON GRADE
H-19 SLOT DRAIN
H-20 42” HIGH CABLE RAIL GUARDRAIL
H-21 STEPS WITH LIMESTONE PAVING TO MATCH ADJACENT
PAVING
H-22 AREA DRAIN
EXISTING ELEMENTS
E-1 EXISTING PLANTERS ON GRADE TO BE PROTECTED IN PLACE
E-2 EXISTING BRICK PAVING TO BE PROTECTED IN PLACE
E-3 EXISITNG PLANTER ON GRADE
E-4 EXISITNG BOAT RAMP
H-12 H-13H-12
H-10
H-11
E-2
E-3
E-1
H-1
H-10
H-1
TYP.
H-20
H-9 H-2
H-17
H-8
H-8
H-6H-7 H-4 H-5
H-3
H-2
H-18
H-15
H-14
H-18
H-20
E-4
H-16
LIGHTING LEGEND
SYMBOL DESCRIPTION QTY.
TREE UPLIGHT AS MANUFACTURED BY AURORA LIGHT 5MODEL: SITKA LSL4-60-WF-30D-H-8x12-BLP-XDLED: 20 WATTS / LUMENS: 1,890
WALL LIGHT AS MANUFACTURED BY AURORA LIGHT 3MODEL - MERIDIAN LSW8-BR-WF-27D-R-FM-BLP-XDLED 1.25 WATTS / LUMENS: 37.5
UNDERWATER LIGHT AS MANUFACTURED BY AURORA LIGHT 3MODEL: ARIEL H2O-P-60-WF-27D-15-S-CS-BLPLED: 4.5 WATTS / LUMENS: 336
LINEAR LED STRIP LIGHTING AS MANUFACTURED BY Q TRAN 31 LFMODEL: OMP-27-BRL-BRL-MATCHLED: 3 WATTS/FOOT / LUMENS: 300/FT
TRANSFORMER TO BE DETERMINED BY CONTRACTOR. COORDINATE FOR 110V ELECTRICAL POWER AS REQUIRED
TOTAL # OF LIGHTS: 11 (not including Linear LED lighting)
TOTAL WATTS: 219.25TOTAL LUMENS: 19,870.5
T
LIGHTING CUT-SHEETS SYMBOL SYMBOL SYMBOL SYMBOL
H-19
H-21
H-21
HOMEOWNERS ASSOCIATION NOTE:
PROJECT LANDSCAPE ARCHITECT HAS REVIEWED THE LINDAISLE COMMUNITY ASSOCIATION ARCHITECTURAL GUIDELINES.
ALL GUIDELINES WERE UNDERSTOOD AND DRAWING PACKAGE
CONFORMS TO ASSOCIATION REQUIREMENTS.
H-22
UP
DN
DN
DN
DN
DN
LI
N
D
A
I
S
L
E
D
R
I
V
E
NE
W
P
O
R
T
B
A
Y
PL
PL
PL
PL
SHEET NO
SHEET PLOTTED :
DRAFTED BY:
SCALE:
REVISIONS
KB
NE
W
P
O
R
T
B
E
A
C
H
,
C
A
L
I
F
O
R
N
I
A
MA
R
I
M
A
N
R
E
S
I
D
E
N
C
E
6/23/2023
2OF
54
L
I
N
D
A
I
S
L
E
NORTH
1/8" = 1'
0 4' 8'16'32'
18" = 1'-0"
P
R
E
L
I
M
I
N
A
R
Y
PL
A
N
T
I
N
G
P
L
A
N
L-2
MARIMAN PLANTING LEGEND
SHRUBS
CAR GRE Carissa grandiflora ‘Green Carpet’ Dwarf Natal Plum
CLI MIN Clivia miniata ‘Mellow Yellow’ Kaffir Lily
CYP PAP Cyperus papyrus PapyrusCYR FAL Cyrtomium falcatum Holly Fern
DIA TAS Dianella tasmanica 'Silver Streak' Silver Streak Flax Lily
LIG TEX Ligustrum texanum N.C.N.
LIR GIG Liriope gigantea Big Blue Lily Turf
PLE REF Pleomele reflexa ‘Indian Song’ N.C.N.
YUC REC Yucca recurviflora Curve Leaf Yucca
ZAM FUR Zamia furfuracea Cardboard Palm
ESPALIERS
MAG LIT Magnolia ‘Little Gem’ Little Gem Magnolia
POD GRA Podocarpus gracilior Fern Pine
VINES
FIC REP Ficus repens Creeping FigLON HIL Lonicera hildebrandiana Burmese Honeysuckle
GROUNDCOVERS
OPH JAP Ophiopogon japonicus Mondo Grass
ROS OFF Rosmarinus ‘Huntington Carpet’ Rosemary
SEN MAN Senecio mandraliscae Senecio Mandraliscae
SHRUBS
CARISSA GRANDIFLORA'GREEN CARPET'CLIVIA MINIATA 'MELLOW YELLOW'
LIGUSTRUM TEXANUM LIRIOPE GIGANTEA
CYPERUS PAPYRUS
PLEOMELE REFLEXA 'INDIAN SONG'
CYRTOMIUM FALCATUM
YUCCA RECURVIFOLIA
DIANELLA TASMANICA'SILVER STREAK'
ZAMIA FURFURACEA
MAGNOLIA 'LITTLE GEM'
PODOCARPUS 'GRACILIOR'
FICUS REPENS
LONICERA HILDEBRANDIANA
OPHIOPOGON JAPONICUS
SENECIO MANDRALISCAE
ROSMARINUS 'HUNTINGTON CARPET'
7FIC REP
1 GAL.
1 YUC REC
24" BOX
12 SEN MAN
1 GAL.
2 MAG LIT
15 GAL ESPALIER
6 LIR GIG
5 GAL.
1 YUC REC
24" BOX
12 SEN MAN
1 GAL.
15 CAR GRE
1 GAL.
6 ROS HUN
1 GAL.
5 FIC REP
1 GAL.
10 LIG TEX
15 GAL.
5 CYR FAL
5 GAL.
5 POD GRA
15 GAL. ESPALIER
11 LIR GIG
5 GAL.
15 OPH JAP
1 GAL.
2 CYP PAP
15 GAL.
16 OPH JAP
1 GAL.
2 CLI MIN
15 GAL.
2POD GRA
15 GAL.
1PLE REF
24" BOX
5DIA TAS
5 GAL.
1ZAM FUR
24" BOX
1PLE REF
24" BOX
5DIA TAS
5 GAL.
ESPALIERS GROUNDCOVERSVINES
3 LON HIL
15 GAL.
CERAMIC CONTAINER WITH SPILLINGPLANTS
HOMEOWNERS ASSOCIATION NOTE:
PROJECT LANDSCAPE ARCHITECT HAS REVIEWED THE LINDA
ISLE COMMUNITY ASSOCIATION ARCHITECTURAL GUIDELINES.
ALL GUIDELINES WERE UNDERSTOOD AND DRAWING PACKAGE
CONFORMS TO ASSOCIATION REQUIREMENTS.