Loading...
HomeMy WebLinkAboutPA2023-0064_20230406_PRR_BldgTmplt: 10/10/12 P ROJECT R EVIEW R EQUES T C O M M U N I T Y D E V E L O P M E N T D E P A R T M E N T Planning Division Please Distribute to: Public Works – D. Keely Building Division – WQMP & Grading – S. Gutierrez Fire/Life Safety – J. Gillespie Date: March 23, 2023 Please return PRR and Plans to Staff Planner Joselyn Perez, Associate Planner 949-644-3312, jperez@newportbeachca.gov Applicant: Daniel Martinez Architect Contact: Daniel Martinez 949.494.7272 daniel@dmadesigns.com Project Name Bollenbacker Residence Address: 2607 Ocean Boulevard (PA2023-0064) Variance, Coastal Development Permit Remodel and addition to an existing single-family dwelling unit resulting in a 3,302 square foot, 4-story, single family dwelling unit with 808 square feet of attached garage parking. REPORT REQUESTED BY: April 6, 2023 Planning Commission HEARING DATE: TBD Check all that apply: ❑ No comments on the project as presented. Notes: 1. Compliance with requirements for emergency escape and rescue openings (EEROs) will be required for all bedrooms and sleeping rooms (CRC R310) in added and altered building areas. A submittal of a Request for Alternate Material or Method of Construction will be required for the EERO serving Bedroom 4 because the 3rd floor projects over the egress path from the opening. 2. Verify that the 1,730sf of proposed new or replaced impervious area documented on the precise grading plan includes the areas where new roof and deck framing will be constructed. If the total area of new or replaced impervious surface materials is at least 5,000sf a Water Quality Management Plan will be required (or at least 2,500sf if the site runoff discharges directly into Newport Bay). 3. Though cut stability analyses have been provided by the geotechnical engineer, shoring will be required for the proposed cuts shown in Sections A-A on sheet A7.0 and D-D on sheets A7.1 and A7.2. 4. Cut stability analyses will be required for the proposed new retaining walls inside the NE property line. These will need to X Application of Standard Code requirements are not expected to alter the project design. ❑ Recommended conditions of approval are attached. ❑ Application of Standard Code requirements or the attached conditions of approval will substantially impact or alter the design of the project. ❑ I contacted the applicant on ❑ To schedule an appt. for Code review ❑ To discuss the following (see notes) Tmplt: 10/10/12 be submitted for review by the Building Division Engineering Geologist. 5. Where new building footings will be constructed adjacent to existing retaining walls as shown in west elevation on sheet A6.1, new footings shall be founded at least as deep as the existing retaining wall footings, or analyses of the existing retaining walls for the new footing surcharge loads will be required. 6. If there is not access to an exterior exit stairway from the upper level, and the maximum travel distance from any occupied point on the upper level to the interior stairway providing egress to the middle level exceeds 50’, a second means of egress from the upper level will be required (CRC R311.4). 7. If the ratio of construction cost to market value for the existing dwelling equals or exceeds 50%, the entire building shall comply with the code provisions for new construction (NBMC 15.02.060). Fire sprinklers are proposed for this project, so the remaining element that will need to be updated to comply with the current code is the capillary break beneath the existing concrete slabs on grade according to 2022 California Green Building Standards Code Section 4.505.2.1. Eric Skarin 3270 04/06/23 Signature Ext. Date Please indicate the approximate time spent on reviewing this project: 2hrs Tmplt: 10/10/12