HomeMy WebLinkAboutH2020-0218 - MiscNZozo -ovg'
tt-t,; n&(�
CERTIFICATE OF COMPLIANCE CFIR-ALT-02-E
Alterations to Space Conditioning Systems (formerly CF-IR-ALT-HVAC) (Page 1 of 3)
Project Name: 1516 Bruinbark Ln. I Date Prepared: 2020-04-14
A. General Information
CFIR-ALT-02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one
CFIR-ALT-02 document for each dwelling unit.
O1
Project Name
1516 Bruinbark Ln.
02
Date Prepared
2020-04-14
03
Project Location
1516 Bruinbark Ln.
04
Building Type
Single family
OS
CA City
Newport Beach
06
Dwelling Unit Name
1516 Bruinbark Ln.
Dwelling Unit Conditioned Floor
07
Zip Code
92660
OS
Area (ft2)
1157
Number of Space Conditioning
09
Climate Zone
6
10
(SC) Systems in this Dwelling
1
Unit:
B. Space Conditioning (SC) System Information
OS
02
03
04
05
06
07
08
09
10
SC System ID or
SC System
CFA served by this
Is the SC system a
Installing a
refrigerant
Installing. new SC
Installing more
Installing entirely
Installing entirely
Name
Location or Area
SC System (ft1)
ducted system?
containing
system
than 40 feet of
new duct system?
new ducted SC
Alteration Type
Served
components?
ducts?
system?
component?
Altered space
System I
Whole House
1157
Yes
Yes
Yes
Yes
No
No
conditioning
system
C. Extension of Existing Duct System, Greater Than 40 Feet (SectioniS0.2(b)SDiib)
This section does not apply to this project.
Registration Number: 220-A020068582A-000-000-0000000-0000
Registration Date/Time: 2020-04-1412:07:33
HERS Provider: CaICERTS
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.002 Report Generated: 2020-04-14 12:07:22
Schema Version: rev 20191201
CERTIFICATE OF COMPLIANCE
CFIR-ALT-02-E
Alterations to Space Conditioning Systems (formerly CF-IR-ALT-HVAC)
(Page 2 of 3)
D. Altered Space Conditioning System (Sections 150.2(b)IE and F)
O1
02
03
04
05
06
07
08
09
10
11
12
13
SC System
Heating
Cooling
Description
Altered
Heating
Minimum
Altered
Cooling
Minimum
Required
New or
System ID/
of Area
Heating
Heating
Efficiency
Efficiency
Cooling
Cooling
Efficiency
Efficiency
Thermostat
Replaced
New Duct
Name
Served
System Type
Components
Type
Value
System Type
Components
Type
Value
Type
Duct Length
R-Value
Central gas
All new
Central split
All new
Greater than
System 1
Whole House
furnace
heating
AFUE
80
AC
cooling
SEER
14
Setback
40 feet
R-6
components
components
Required Documentation:
CF2R-MCH-01-E - Space Conditioning Systems
- Duct insulation requirement for the new portions of supply -air and return -air ducts or plenums: R6 (CZ 1-10, 12 and 13) and R8 (CZ 11 and 14-16)
CF2R and CF311-MCH-20-H - Duct Leakage Test required when heating or cooling components are installed in ducted systems, or when more than 40 ft of duct length is
replaced
-Leakage rate compliance: <= 15 percent or <= 10 percent leakage to outside, or seal all accessible leaks.
CF2R and CF3R-MCH-25-H Refrigerant Charge verification required when refrigerant containing components are installed or altered (applicable in CZ 2, 8-15).
CF2R and CF3R-MCH-23 Airflow Rate>= 300 CFM per ton required when MCH-25 is required.
Exceptions:
- Duct systems registered with HERS provider as previously sealed are exempt from MCH-20 Duct Leakage Testing requirements.
- Heating -only systems and Air Handler Furnace changes do not require verification of Air Flow MCH-23, or Refrigerant Charge MCH-25.
-Existing duct systems constructed, insulated or sealed with asbestos are exempt from MCH-20 Duct Leakage Testing requirements,
E. Entirely New or Complete Replacement Duct System, with or without Equipment Changeout (Sections 150.Z(b)1Diia and 150.2(b)1E, F)
This section does not apply to this project.
F. Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)IC)
This section does not apply to this project.
Registration Number: 220-A020068582A-000-000-0000000-0000
Registration Date/Time: 2020-04-14 12:07:33
HERS Provider: CaICERTS
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.002 Report Generated: 2020-04-14 12:07:22
Schema Version: rev 20191201
CERTIFICATE OF COMPLIANCE CFIR-ALT-02-E
Alterations to Space Conditioning Systems (formerly CF-IR-ALT-HVAC) (Page 3 of 3)
Documentation Author's Declaration Statement
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Sobenes, Sara M
Documentation Author Signature:
ara LWSoCenes
Company:
Signature Date:
Plus Air Duct Testing
2020-04-14 12:07:33
Address:
CEA/ HERS Certification Identification (if applicable):
6843 Regal Park Dr.
96126
City/State/Zip:
Phone:
Fontana CA 92336
909-273-7272
Responsible Person's Declaration statement
I certify the following under penalty of perjury, underthe laws of the State of California:
1. The information provided on this Certificate of Compliance is true and correct.
2. I am eligible under Division 3 ofthe Business and Professions Codeto accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer).
3. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the
requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency forapproval with this building permit application.
S. I will ensure that a registered copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable
inspections. I understand that a registered copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy.
Responsible Designer Name:
Sobenes, Sara M
Responsible Designer Signature:
Sara Sig Cns
CW
Company:
Date Signed:
Plus Air Duct Testing
2020-04-14 12:07:33
Address:
License:
6843 Regal Park Dr.
909834
City/State/Zip:
Phone:
Fontana CA 92336
909-273-7272
Easy to Verify o 0
at CaICERTS.com
Digitally signedby CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies
O_
Registration Provider responsibility for the accuracy of the information.
Registration Number: 220-A020068582A-000-000-0000000-0000
Registration Date/Time: 2020-04-1412:07:33
HERS Provider: CaICERTS
CA Building Energy Efficiency Standards - 2019 Residential Compliance Report Version: 2019.1.002 Report Generated: 2020-04-14 12:07:22
Schema Version: rev 20191201