Loading...
HomeMy WebLinkAboutPA2023-0112_20230531_Plans_36x24CLIENT / APPLICANT: PROJECT TITLE: DESIGNER / EXPEDITOR: RAMON BAGUIO 4273 CANOGA AVE WOODLAND HILLS, CA 310-562-5382 RBPLANDESIGN@GMAIL.COM WWW.CALPLANDESIGN.COM 04 - 26 - 23 PROJECT ADDRESS: PROJECT DESCRIPTION: SHEET TITLE: PROJECT CONTACT: DRAWN BY: YU (E) RESTAURANT PROPOSED (N) BAR C w V I Y d    C . ʍ C  ɿ 2 6 6 ɷ ʍ h S  ɷ0 6 B  0 C S d Y   d (E ) R E S T A U R A N T P R O P O S E D ( N ) B A R C.S. 106 MAIN STREET, NEWPORT BEACH, CA, 92661 ASSESSOR MAP, NTS NORTH PARCEL ID: 048-132-07 PARCEL ADDRESS ZIP CODE: 92661-1324 VICINITY MAP, NTS THIS SITE NORTH GENERAL NOTES: 1. GENERAL CONTRACTOR (G.C) TO REVIEW AND VERIFY ALL JOB CONDITIONS, DIMENSIONS, AND DETAILS PRIOR TO BIDDING, PRICING AND CONSTRUCTION TO DETERMINE WHICH NOTES APPLY DIRECTLY TO GENERAL CONTRACTOR'S RESPONSIBILITY. G.C. TO MAKE NOTE AND SUBMIT IN WRITTEN FORM TO DESIGNER ANY DAMAGES OR DEFICIENCIES, NOTES OR SPECIFICATIONS. 2.ALL WORK SHOWN OR IMPLIED, UNLESS SPECIFICALLY QUESTIONED, SHALL BE CONSIDERED FULLY UNDERSTOOD IN ALL RESPECTS BY THE GENERAL CONTRACTOR. 3.DRAWINGS ARE NOT TO BE SCALED, WRITTEN DIMENSIONS GOVERN. LARGER SCALE DRAWINGS GOVERN SMALLER SCALE DRAWINGS. 4.DRAWINGS AND NOTES ARE COMPLEMENTARY. ANY WORK SHOWN OR REFERRED TO ON ANY ONE DRAWING SHALL BE PROVIDED AS THOUGH SHOWN ON ALL RELATED DRAWINGS. 5.GENERAL CONTRACTOR SHALL COMPLY WITH ALL RULES AND REGULATIONS OF BUILDING MANAGEMENT, IF ANY, IN ALL RESPECTS INCLUDING TRASH DISPOSAL, PARKING, HOURS OF OPERATION, ETC. GENERAL CONTRACTOR IS RESPONSBILE TO ADHERE TO SUCH REGULATIONS FROM THESE DRAWINGS AND TO PROVIDE A COPY FOR REVIEW BY ALL SUB-CONTRACTORS. G.C. TO NOTIFY DESIGNER / OWNER OF ANY CONFLICTS BETWEEN REGULATIONS AND OTHER CONTRACTUAL DOCUMENTS PRIOR TO PROCEEDING WITH ANY WORK. 6. ALL WORK TO BE PERFORMED IN PUBLIC AREAS SHALL BE PERFORMED AS REQUIRED BY BUILDING RULES AND REGULATIONS UNLESS OTHERWISE ARRANGED WITH OWNER. 7.GENERAL CONTRACTOR TO MAINTAIN A CURRENT AND COMPLETE SET OF CONSTRUCTION DRAWINGS ON SITE DURING ALL PHASES OF CONSTRUCTION FOR USE OF ALL TRADES. 8.GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF ALL TRADES AND WORK RELATED SPECIALTIES REQUIRED IN ORDER FOR PROJECT AND ITS PARTS TO COME TOGETHER PROPERLY AND FIT TO RECEIVE OR BE RECEIVED BY WORK OF OTHER TRADES AND CONTRACTOR'S IMPLIED BY DRAWINGS OR NOTES. 9.GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SCHEDULING AND FOR FEES FOR HOISTING EQUIPMENT AS MAY BE REQUIRED BY THE WORK OF THE PROJECT. 10.ALL WORK SHALL CONFORM TO DRAWINGS AND SPECIFICATIONS BY DESIGNER AND OTHER PROJECT CONSULTANTS AND SHALL BE NEW AND OF THE BEST QUALITY OF KINDS SPECIFIED. ALL MANUFACTURER ARTICLES TO BE INSTALLED, CONNECTED CONDITIONED AS DIRECTED BY MANUFACTURER, ALL WORK TO BE PERFORMED IN A GOOD WORKMANSHIP MANNER. 11.SUB-CONTRACTORS SHALL BE RESPONSIBLE FOR REVIEWING AND UNDERSTANDING ENTIRE SET OF DRAWINGS AND NOTING THEIR WORK AS APPLICABLE. ALL SHOP DRAWINGS SHALL BE SUBMITTED TO DESIGNER FOR REVIEW , COMMENT, AND APPROVAL BY WAY OF GENERAL CONTRACTOR PRIOR TO COMMENCEMENT OF WORK. 12.GENERAL CONTRACTOR TO BE SOLELY RESPONSIBLE FOR REMOVAL, REPLACEMENT, AND RECTIFICATION OF ALL DAMAGED AND DEFECTIVE MATERIAL AND/ OR WORKMANSHIP IN CONNECTION WITH THE CONTRACT WORK WHICH SHALL APPEAR WITHIN ONE YEAR FROM THE DATE OF SUBSTANTIAL COMPLETION AS DIRECTED BY DESIGNER ANY COST ACCRUED BY DEFECTIVE OR ILL-TIMED WORK AS A RESULT OF, BUT NOT LIMITED TO, INTERIOR WORKMANSHIP OR MATERIALS, POOR SCHEDULING OR DELINQUENT ORDERING SHALL BE BORNE BY THE PARTY RESPONSIBLE. 13.DURING ENTIRE PERIOD OF DEMOLITION AND CONSTRUCTION ANY AND ALL REQUIRED EXISTING EXITS, EXIT LIGHTING AND FIRE PROTECTIVE SERVICES SHALL BE PROPERLY MAINTAINED. ALL WAYS OF TRAVEL FROM EXITS TO THE STREET SHALL BE MAINTAINED FREE FROM ALL OBSTRUCTIONS IN CASE OF FIRE OR OTHER EMERGENCY. 14.GENERAL CONTRACTOR SHALL PROPERLY PROTECT THE BUILDING AND ANY ADJOINING PROPERTY OR WORK, AND PROTECT ALL EXISTING SURFACES OR FINISHES TO REMAIN DURING DEMOLITION AND CONSTRUCTION. ANY DAMAGE TO THE SAME SHALL BE REPAIRED BY GENERAL CONTRACTOR AT G.C.'S EXPENSE TO 'LIKE-NEW' CONDITION. 15.GENERAL CONTRACTOR SHALL VERIFY ALLOWED WORKING HOURS FOR ALL WORK DONE TO THE CORE TO INCLUDE DRILLING, PATCHING, AND ELECTRICAL HOOK-UPS AND IS RESPONSIBLE FOR ALL COSTS NECESSARY TO COMPLY WITH SUCH HOURS WITHIN BASE BID. 16.GENERAL CONTRACTOR IS RESPONSIBLE TO MAINTAIN JOBSITE CLEANLINESS AND REMOVAL OF ALL WASTE MATERIALS FROM PREMISES AS GENERATED BY CONSTRUCTION DEMOLITION, DRYWALLING, AND ALL TRADE RELATED WORK BY CONTRACTURAL WORK. 17.ALL WORK NOTED N.I.C. OR 'BY TENANT' OR 'BY OWNER' IS TO BE ACCOMPLISHED BY PERSONS OTHER THAN GENERAL CONTRACTOR AND IS NOT TO BE PART OF CONSTRUCTION AGREEMENT. 18.GENERAL CONTRACTOR SHALL SECURE ALL REQUIRED PERMITS AND FEES ASSOCIATED WITH ALL BUILDING & SAFETY DEPARTMENTS AND FORWARD COPIES TO APPROPRIATE PERSONNEL I.E. DESIGNER, AND / OR OWNER REPRESENTATIVE. 19.GENERAL CONTRACTOR TO PROVIDE CONSTRUCTION SCHEDULE, AND LIST OF LONG LEAD ITEMS THAT MAY CAUSE DELAY WITH SCHEDULING BY END OF FIRST WEEK OF CONSTRUCTION. 20. GENERAL CONTRACTOR SHALL SUBMIT SAMPLES, AND CUT-SHEETS WHERE REQUESTED FOR WRITTEN APPROVAL BY DESIGNER, OR OWNER PRIOR TO MATERIAL ORDERING. NO MATERIAL SUBSTITUTIONS SHALL BE MADE WITHOUT PRIOR CONSENT OF DESIGNER, AND / OR OWNER. 21.GENERAL CONTRACTOR TO SUBMIT IN WRITING ALL CHANGE ORDERS FOR ADDITIONAL WORK TO DESIGNER OR OWNER REPRESENTATIVE FOR REVIEW AND APPROVAL. NO WORK IS TO PROCEED UNTIL A SIGNED CHANGE ORDER IS RETURNED TO GENERAL CONTRACTOR UNLESS NOTED OTHERWISE. ANY AND ALL CHANGES IN THE FIELD SHALL BE APPROVED AND SIGNED BY THE DESIGNER AND / OR OWNER. 22.UPON COMPLETION OF THE WORK, THE GENERAL CONTRACTOR SHALL PROVIDE TO OWNER: A. COPY OF INSPECTIONS REPORT & FINAL SIGN-OFF B. CERTIFICATE OF SUBSTANTIAL COMPLETION (AIA DOCUMENT #G704) C. COPY OF PERMIT CARD D. BUILDING DEPARTMENT APPROVED DRAWINGS E. WARRANTIES FOR SPECIFIED MATERIALS F. RECORD/ AS-BUILD DOCUMENTS FOR M.E.P. SUB-TRADES G. ELECTRICAL PANEL SCHEDULE 23.OCCUPANCY DURING CONSTRUCTION: AREA OF WORK SHALL BE OCCUPIED BY DURING CONSTRUCTION. ADJACENT AREAS ARE OCCUPIED DURING CONSTRUCTION. 24. ALL EQUIPMENT, PRODUCTS, AND MANUFACTURED MATERIAL SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. GENERAL CONTRACTOR IS RESPONSIBLE FOR FOLLOWING THE MANUFACTURERS INSTALLATION INSTRUCTIONS IN ALL RESPECTS. 25.ALL WORK SHALL COMPLY WITH THE REGULATIONS OF THE GOVERNMENTAL AUTHORITIES HAVING JURISDICTION. THE SPECIFICATIONS SHALL BE SUPPLEMENTAL TO ALL LAWS AND CODES OF GOVERNMENTAL REGULATING BODIES RELATING TO BUILDINGS, AND ALL APPLICABLE REQUIREMENTS SPECIFIED IN THESE REGULATIONS SHALL BE FOLLOWED AS THOUGH SPECIFICALLY NOTED BY SUCH CODES OR LAWS. IT IS THE GENERAL CONTRACTOR'S RESPONSIBILITY TO NOTIFY dESIGNER OF ANY CONFLICTS BETWEEN THESE DRAWINGS AND LOCAL BUILDING CODES AS SOON AS THEY BECOMEAWARE OF THEM. 26.DESIGNER AND OWNER SHALL HAVE ACCESS TO THE AREA OF WORK AT ALL TIMES AND SHALL CONDUCT PERIODIC VISITS TO DETERMINE OVERALL PROGRESS AND QUALITY OF THE WORK, AND TO CONFIRM GENERAL COMPLIANCE WITH CONTRACT DOCUMENTS. DESIGNER SHALL HAVE NO RESPONSIBILITY FOR MEANS AND METHODS OF CONSTRUCTION WHICH REMAIN THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR. 27.DESIGNER SHALL HAVE THE RIGHT TO REJECT WORK WHICH DOES NOT CONFORM TO THE CONTRACT DOCUMENTS OR IS OF SUB-STANDARD QUALITY. GENERAL CONTRACTOR SHALL CORRECT SUCH WORK AS DIRECTED. ADDITIONAL COSTS ACCRUED BY NEGLECT OF THE GENERAL CONTRACTOR IS THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO ABSORB SUCH FEES ASSOCIATED WITH SUB-STANDARD WORKMANSHIP. 28.ANY SCOPE OF WORK SUMMARIES ON THIS SHEET ARE PROVIDED FOR THE CONVENIENCE OF THE CONTRACTOR AND TO CLARIFY SCOPE OF WORK. THEY ARE SUPPLEMENTAL TO THE WORK OUTLINED ELSEWHERE IN DESIGNER'S AND / OR CONSULTANT'S DRAWINGS AND SPECIFICATIONS AND DO NOT SUPERCEDE THAT INFORMATION. THE OMISSION ON AN ITEM ON THESE SUMMARIES, THAT IS DEFINED ELSEWHERE IN THE BID PACKAGE, CANNOT BE TAKEN AS INDICATION THAT THAT ITEM IS OMITTED FROM GENERAL CONTRACTOR SCOPE OF WORK. 29.GENERAL CONTRACTOR TO PROVIDE WRITTEN LETTER OF CONSENT HAVING READ ALL AND UNDERSTANDING OF THESE TERMS AND CONDITIONS OF THESE DRAWINGS, ANY AND ALL QUESTIONS WILL BE INQUIRED PRIOR TO START OF CONSTRUCTION. APPLICABLE CODES: 1. 2022 CBC 2. 2022 CPC 3. 2022 CMC 4. 2022 CALIFORNIA FIRE CODE (CFC). BUILDING INFO: BUILDING AREA:2,710 SF (E) COMMERCIAL SPACE.: LOT SIZE: (N) ADDITION FLOOR AREA TOTAL: OCCUPANCY & CONSTRUCTION TYPE: CONST. TYPE: FIRE PROTECTION: OCCUPANCY: NUMBER OF STORIES:2 MAXIMUM HEIGHT: N/A 2,204 SQ.FT. 2,710 SQ.FT 2,710 SQ.FT TYPE V-B SPRINKLERED SHEET INDEXPARKING MATRIX CS: COVER SHEET S.P.: SITE PLAN A1: (E) FLOOR PLAN & (E) ROOF PLAN A2: (N) FLOOR PLAN A3:EQUIPEMENT AND FURNITURE PLAN A4: SPEC. SHEET & FIXTURE SCHEDULE A5: (E) ELEVATIONS -PARKING TO REMAIN ASSESSOR MAP, NTS NORTH DATE: COVER SHEET A-2 SCOPE OF WORK: -(E) RESTAURANT PROPOSED (N) BAR -ALL (E) WALLS, DOORS & STORE FRONT ARE TO REMAIN -NO STRUCTURAL WORK PROPOSED -NO ADDITIONAL SF PROPOSED -REPAIR PLUMBING & HVAC -MECHANICAL, ELECTRICAL & PLUMBING UNDER DIFFER PERMIT Gegam Burnazyan MLB Consulting and Engineering 7918 Foothill Blvd, Sunland, CA (818)-521-6342 CIVIL ENGINEER CIVIL ENGINEER Gegam Burnazyan MLB Consulting and Engineering 7918 Foothill Blvd, Sunland, CA (818)-521-6342 MEP ENGINEER Usama Tohid P.E. (213)926-5961 usama@prvengineers.com PRV ENGINEERS 24' 1855 SF 106 MAIN ST. NEWPORT BEACH,CA 92661 MAIN ST OC E A N F R O N T A L L E Y MAIN ST ADJACENT PROPERTY NOT IN SCOPEPL : 7 6 ' PL:29' PL:29' SIDE WALK SIDE WALK MAIN ENTRANCE SERVICE ENTRANCE TRASH CONTAINER AREA GREASE TRAP PL : 7 6 ' Gypsum wall 16d nails 8d Nails or 14 ga. Treated sill plate. Concrete slab/(E) FOOTING. Sill sealer. Insect clip Caulk Cementitious board. by code.as req'd 1 1/2" staples @ 6" o.c. each sideor equivalent. or flashing. coat.scratch 6" 6" 12" ALL THREAD EPOXIED MIN 3" INTO (E) GARAGE SLAB SPACING @12"0C 7 SET X/P EPOXY 8" (N) 6"hX8"W CONCRETE 2500PSI CURB ALONG ENTIRE LENGTH OF FORMER GARAGE DOOR OPENING (N) STUCCO TO MATCH EXISTING (N) R19 INSULATION SITE DEVELOPMENT & ACCESSIBLE ROUTE OF TRAVEL 1. SITE DEVELOPMENT AND GRADING SHALL BE DESIGNED TO PROVIDE ACCESS TO ALL ENTRANCES AND EXTERIOR GROUND FLOOR EXITS, AND ACCESS TO NORMAL PATHS OF TRAVEL, AND WHERE NECESSARY TO PROVIDE ACCESS, SHALL INCORPORATE PEDESTRIAN RAMPS, CURB RAMPS, ETC. WALKS & SIDEWALKS 1. WALKS AND SIDEWALKS SHALL HAVE A CONTINUOUS COMMON SURFACE, NOT INTERRUPTED BY STEPS OR BY ABRUPT CHANGES IN LEVEL EXCEEDING 1/2", AND SHALL BE A MINIMUM OF 48" IN WIDTH. 2. WHEN ABRUPT CHANGES IN LEVEL NOT EXCEEDING 1/2" OCCUR, THEY SHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1:2, EXCEPT THAT LEVEL CHANGES NOT EXCEEDING 1/4" MAY BE VERTICAL. 3. ABRUPT CHANGES IN LEVEL ALONG ANY ACCESSIBLE ROUTE EXCEEDING 1/2" SHALL COMPLY WITH THE REQUIREMENTS FOR CURB RAMPS. 4. WHEN THE SLOPE IN THE DIRECTION OF TRAVEL OF ANY WALK EXCEEDS 1 VERTICAL TO 20 HORIZONTAL IT SHALL COMPLY WITH THE PROVISIONS OF A PEDESTRIAN RAMP 5. WALK AND SIDEWALK SURFACE CROSS SLOPES SHALL NOT EXCEED 1/4" PER FOOT. 6. WALKS SHALL BE PROVIDED WITH A LEVEL AREA NOT LESS THAN 60" BY 60" AT A DOOR OR GATE THAT SWINGS TOWARD THE WALK, AND NOT LESS THAN 48" WIDE BY 44" DEEP AT A DOOR OR GATE THAT SWINGS AWAY FROM THE WALK. 7. WALKS SHALL EXTEND A MINIMUM OF 24" TO THE SIDE OF THE STRIKE EDGE OF A DOOR OR GATE THAT SWINGS TOWARD THE WALK. 8. ALL WALKS WITH CONTINUOUS GRADIENTS SHALL HAVE LEVEL AREAS AT LEAST 5 FT. IN LENGTH AT INTERVALS OF AT LEAST EVERY 400 FT. 9. WALK AND SIDEWALK SURFACES SHALL BE SLIP-RESISTANT AS-FOLLOWS: A. SURFACES WITH A SLOPE OF LESS THAN 6% GRADIENT SHALL BE AT LEAST AS SLIP- RESISTANT AS THAT DESCRIBED AS A MEDIUM STALED FINISH. (SEE PLANS FOR ACTUAL FINISH.) B. SURFACES WITH A SLOPE OF 6% GRADIENT OR GREATER SHALL BE SLIP-RESISTANT. 10. WALKS, SIDEWALKS, AND PEDESTRIAN WAYS SHALL BE FREE OF GRATINGS WHENEVER POSSIBLE. FOR GRATINGS LOCATED IN THE SURFACE OF ANY OF THESE AREAS, GRID OPENINGS IN GRATINGS SHALL BE NO GREATER THAN 1/2" WIDE IN ONE DIRECTION. IF GRATINGS HAVE ELONGATED OPENINGS, THEY SHALL BE PLACED SO THAT THE LONG DIMENSION IS PERPENDICULAR TO THE DOMINANT DIRECTION OF TRAVEL. RAMPS NOTE: ANY PATH OF TRAVEL SHALL BE CONSIDERED A RAMP IF ITS SLOPE IS GREATER THAN 1 FT. RISE IN 20 FT. OF HORIZONTAL RUN. 1. THE MAXIMUM SLOPE OF A RAMP THAT SERVES ANY EXITWAY, PROVIDES ACCESS FOR PERSONS WITH DISABILITIES, OR IS IN THE PATH OF TRAVEL SHALL BE 1 FT. RISE IN 12 FT. OF HORIZONTAL RUN. 2. THE CROSS SLOPE OF RAMP SURFACES SHALL BE NO GREATER THAN 1:50 (1/4"/ FT.). 3. THE WIDTH OF RAMPS SHALL BE AS REQUIRED FOR STAIRWAYS AND EXITS. 4. DOORS IN ANY POSITION SHALL NOT REDUCE THE MINIMUM DIMENSION OF THE RAMP LANDING TO LESS THAN 42" AND SHALL NOT REDUCE THE REQUIRED WIDTH BY MORE THAN 3" WHEN FULLY OPEN. 5. RAMP LANDINGS AREA NOT CONSIDERED IN DETERMINING THE MAXIMUM HORIZONTAL DISTANCE OF EACH RAMP. 6. HANDRAILS ARE REQUIRED ON RAMPS THAT PROVIDE ACCESS IF THE RAMP SLOPE EXCEEDS 1 FT. RISE IN 20 FT. OF HORIZONTAL RUN. HANDRAILS REQUIRED ON BOTH SIDES OF RAMP. 7. THE GRIP PORTION OF HANDRAILS SHALL BE NOT LESS THAN 1-1/4" NOR MORE THAN 1-1/2", OR THE SHAPE SHALL PROVIDE AN EQUIVALENT GRIPPING SURFACE, AND ALL SURFACES SHALL BE SMOOTH WITH NO SHARP CORNERS. HANDRAILS SHALL NOT ROTATE WITHIN THEIR FITTINGS 8. HANDRAILS PROJECTING FROM A WALL SHALL HAVE A SPACE OF 1-1/2" BETWEEN THE WALL AND THE HANDRAIL. 9. MOUNT HANDRAILS AT 34" TO 38" ABOVE THE RAMP. 10. ANY WALL OR OTHER SURFACE ADJACENT TO HANDRAILS SHALL BE FREE OF SHARP OR ABRASIVE ELEMENTS. EDGES SHALL HAVE A MINIMUM RADIUS OF 1/8. PARKING 1. SURFACE SLOPES OF ACCESSIBLE PARKING SPACES SHALL BE THE MINIMUM POSSIBLE AND SHALL NOT EXCEED 1/4" PER FOOT IN ANY DIRECTION. 2. PEDESTRIAN WAYS WHICH ARE ACCESSIBLE TO PEOPLE WITH DISABILITIES SHALL BE PROVIDED FROM EACH SUCH PARKING SPACE TO RELATED FACILITIES, INCLUDING CURB CUTS OR RAMPS AS NEEDED. 3. ACCESSIBLE PARKING SPACES SHALL BE SO LOCATED THAT PERSONS WITH DISABILITIES ARE NOT COMPELLED TO WHEEL OR WALK BEHIND PARKED CARS OTHER THAN THEIR OWN. 4. SIGNS TO IDENTIFY ACCESSIBLE PARKING SPACES MAY BE CENTERED ON THE WALL AT THE INTERIOR END OF THE PARKING SPACE AT A MINIMUM HEIGHT OF 36" FROM THE PARKING SPACE FINISHED GRADE, GROUND OR SIDEWALK. 5. VAN ACCESSIBLE PARKING SPACES SHALL HAVE AN ADDITIONAL SIGN STATING "VAN- ACCESSIBLE" MOUNTED BELOW THE SYMBOL OF ACCESSIBILITY. PROJECT TITLE: PROJECT DESCRIPTION: SHEET TITLE: DRAWN BY: YU NE W P O R T B E A C H , C A 9 2 6 6 1 , U S A 10 6 M A I N S T R E E T SʒPʒ 1/S.P.:SITE PLAN, 3/16"=1'-0 NORTH 0ɺ ʣ 26 ʣ 2ɹ 3/S.P.: CURB SECTION DETAIL, NTS DATE: 2/S.P.: CURB SECTION DETAIL, NTS SITE PLAN EM CLIENT / APPLICANT: DESIGNER / EXPEDITOR: RAMON BAGUIO 4273 CANOGA AVE WOODLAND HILLS, CA 310-562-5382 RBPLANDESIGN@GMAIL.COM WWW.CALPLANDESIGN.COM PROJECT ADDRESS: PROJECT CONTACT: Gegam Burnazyan MLB Consulting and Engineering 7918 Foothill Blvd, Sunland, CA (818)-521-6342 CIVIL ENGINEER (E) RESTAURANT PROPOSED (N) BAR (E ) R E S T A U R A N T P R O P O S E D ( N ) B A R EMERGENCY EXIT (E) MEZZANINE SEATING DN 16'-1" 17'-8"10'-0" 8' - 4 " 6' - 9 " 2' - 6 " 1' - 3 " 16 ' - 1 0 " 9' - 1 0 " 8' - 6 " 9' - 0 " 11'-7" 5'-0" 15'-0" 6' - 9 " 3'-0"2'-0" 7' - 1 " 8'-1" 3' - 9 " 4' - 1 " 6'-8" DOWN 3'-10" (E ) P A N E L S (E ) T E L C A B L E S 11'-9"4'-11" 12'-0" 9' - 0 " 8' - 9 " 10 ' - 9 " 29 ' - 1 0 " 7' - 8 " 6' - 6 " 9' - 3 " 9' - 7 " 6' - 9 " 33 ' - 5 " 1' - 2 " 2'-0"13'-4"2'-5"5'-9"5'-2" 28'-8" UP UP GREASE TRAP 3'-6" HVAC CURB ROOF HATCH CONDENSER UNIT CONDENSER UNIT WATER HEATER 2/A1: (E) SECOND FLOOR PLAN, 1/4"=1' 1/A1: (E) FLOOR PLAN, 1/4"=1'NORTH NORTH PROJECT TITLE: DATE: PROJECT DESCRIPTION: SHEET TITLE: DRAWN BY: YU C w V I Y d      . ʍ     9 2 6 6 1 ʍ  h ]  10 6  B  0 C  ] d Y   d 1 04-26-23 3/A1: (E) ROOF PLAN, 1/4"=1'-0 NORTH ..\..\..\OneDrive\Desktop\Work yu\DROPBOX\Ramon Baguio\RBCAS\106 MAIN ST. NEWPORT BEACH\PDF\24X24 ROOF HATCH.png ..\..\..\OneDrive\Desktop\Work yu\DROPBOX\Ramon Baguio\RBCAS\106 MAIN ST. NEWPORT BEACH\PDF\R-LADDER.png ..\..\..\OneDrive\Desktop\Work yu\DROPBOX\Ramon Baguio\RBCAS\106 MAIN ST. NEWPORT BEACH\PDF\R-LADDER2.png ROOF HATCH RETRACTABLE LADDER ALL EQUIPEMENT SHOULD MATCH SPEC SHEET PROVIDED OR PROVIDE EQUIVALENT. INSPECTION WILL BE REQUIRED AFTER INSTALLATION. NOTES: (E) FLOOR PLAN EM CLIENT / APPLICANT: DESIGNER / EXPEDITOR: RAMON BAGUIO 4273 CANOGA AVE WOODLAND HILLS, CA 310-562-5382 RBPLANDESIGN@GMAIL.COM WWW.CALPLANDESIGN.COM PROJECT ADDRESS: PROJECT CONTACT: Gegam Burnazyan MLB Consulting and Engineering 7918 Foothill Blvd, Sunland, CA (818)-521-6342 CIVIL ENGINEER (E) RESTAURANT PROPOSED (N) BAR (E ) R E S T A U R A N T P R O P O S E D ( N ) B A R (E) FOOD PREP TO REMAIN 2 (E) WASHWARE AREA (E) RESTRM HAND SINK (N)BAKERS PRIDE PIZZA (E) 4 BURNER W GRIDDLE DEEP FRYER DEEP FRYER FLR SINK FLRSINK JAN RACK MOP SINK FD (E) HOOD (E) FOOD PREP TO REMAIN 1 (E) RESTRM (E ) P A N E L S (E ) T E L C A B L E S (E) CLOSET (E) WI RFG 1 (E) WI RFG 2 (E) WI FRZ HA N D SIN K 32"H PONY WALL FOR ADA SECTION OF BAR AD A B A R S E A T I N G (N ) 3 C O M P B A R S I N K (N) ICE MACHINE ADA ADA (N) BAR 16 BAR SEATING 43 TOPS 1ST FLR HOST (E) SANDWICH PREP HANDSINK S. STEEL COUNTER S. STEEL COUNTER S. STEEL COUNTER 11'-9"4'-11" 12'-0" 9' - 0 " 8' - 9 " 10 ' - 9 " 29 ' - 1 0 " 7' - 8 " 6' - 6 " 9' - 3 " 9' - 7 " 6' - 9 " 33 ' - 5 " 1' - 2 " 2'-0"13'-4"2'-5"5'-9"5'-2" 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 28'-8" 33'-9" (N) 48" COUNTER HEIGHT RFG (N) WARMING TOP (N) 36"X30'' RFG TRIPLE SINK W/ 18" DRAINBOARD ON BOTH SIDES 7'-6" 1'-6" 1'-6"1'-6" 1'-6" OPEN TAP STATION (N) SODA FOUNTAIN 1-COMP PREP SINK 18"1'-6" 1'-6" 1 2 3 (E) 3 - PREP SINK (E) 1-COMP PREP SINK(E) MOP SINK (E) FRYERS (E) HAND SINK (E) HAND SINK METRO 18X48 WIRE SHELVING ME T R O 1 8 X 4 8 WIR E S H E L V I N G UP LEGEND: 1 7 7 3 2 4 1313 13 17 18 16 12 10 20 19 (E) DINING AREA 1 (E)1 (E)2 FL R SIN K FD (N)1 (N)1 (E)1 14 15 11 UP GREASE TRAP (E) D1 (E) D2 (E) D3 (E) D4 (E) D5 (E) D5 (E) D6 (E) D6 (E) D7 9 6 13'-111 2" 2'-7" 3'-6" 3'- 1 1 2" 1' - 1 1 " 1'-6"4"8" 6'-6" 3' - 1 " 7'-6" 15'-8" 27'-8" 6' - 6 " 5'-5"9'-9" (E) W2 (E) W3 (E) W1 (E) W4 (E) W5 (E) DRY STORAGE & ALCOHOL STORAGE EMERGENCY EXIT FLRSINK (E) OFFICE ROOM (E) FOOD PREP TO REMAIN 3 (E) MEZZANINE SEATING DN 28 TOPS 2ND FLR 16'-1" 17'-8"10'-0" 8' - 4 " 6' - 9 " 2' - 6 " 1' - 3 " 16 ' - 1 0 " 9' - 1 0 " 8' - 6 " 9' - 0 " 11'-7" 45 3 6 11 12 13 14 15 16 17 18 2019 22 23 21 24 26 27 25 28 5'-0" 15'-0" 6' - 9 " 3'-0"2'-0" 7' - 1 " 8'-1" 3' - 9 " 4' - 1 " METRO 18X48 WIRE SHELVING METRO 18X48 WIRE SHELVING ME T R O 1 8 X 4 8 WIR E S H E L V I N G ME T R O 1 8 X 4 8 WIR E S H E L V I N G 6'-8" BOOTH TO REMAIN (N ) S E T T E C H A I R ST E E L C O U N T E R 4 5 10 9 8 ROOF HATCH HVAC ROOF CURB (E) DINING AREA 2 (E)3 FD (E)23 13 DOWN (E) D3 (E) D3 (E) D7 7 2 1 3'-10" 1. JOINTS INSTALLED IN OR BETWEEN FIRE-RESISTANCE RATED WALLS, FLOOR OR FLOOR/CEILING ASSEMBLIES AND ROOFS OR ROOF/CEILING ASSEMBLIES SHALL BE PROTECTED AN APPROVED FIRE-RESISTANT JOINT SYSTEM WITH A FIRE-RESISTANCE RATING NOT LESS THAN THAT OF THE ASSEMBLY IN WHICH IT IS INSTALLED. PROVIDE DETAILS. (CBC 715.1) 2. FIRE DOORS ASSEMBLIES SHALL ALSO MEET THE REQUIREMENTS FOR A SMOKE AND DRAFT CONTROL ASSEMBLY. (CBC 716.2.1.4) 3. FIRE DOORS AND FIRE PROTECTION RATED GLAZING SHALL BEAR LABELS ARE REQUIRED BY CBC 716.2.9 AND 716.3.5. 1. ALL (E) ENTRANCES / EXITS TO REMAIN a. SIGN ABOVE ALL EXIT DOORS: "DOORS TO REMAIN UNLOCKED DURING OPERATIONAL HOURS" 2. DOORS WITH GLASS ARE TEMPERED 3. EXTERIOR DOORS TO HAVE LANDING MIN 36" WITH 2% GRADE AWAY FROM DOOR 4. ALL DOORS SELF CLOSING , 4/A2 5. ALL DOORS TO BE EQUIPPED WITH ADA COMPLIANT HARDWARE 8. ALL DOORS ARE OPENABLE FROM THE INSIDE WITHOUT USE OF A KEY, SPECIAL KNOWLEDGE OR EFFORT (E) WALLS TO REMAIN DOOR SCHEDULE & NOTES WALL LEGEND (E) WALLS TO REMAIN ALL DOORS TO HAVE ADA LEVER HANDLE HARDWARE ALL DOORS EXCEPT THE RESTROOM DOORS TO BE EQUIPPED WITH CARD READING HARDWARE WALL & DOOR NOTES FILLIN OPENING, 2X4 WOOD CONSTRUCTION @ 16"OC, 58" TYPE X GWB ON BOTH SIDES (E) WALLS & DOORS TO DEMO (E) W1 DESIGNATION DIMS 36"WX48"H, FIXED WINDOW WINDOW SCHEDULE OPERATIONAL NO 104"WX86"H, FIXED WINDOW NO 104"WX48"H, FIXED WINDOW NO (E) W2 (E)W3 18"WX36"H, FIXED WINDOW NO (E)W4 18"WX48"H, FIXED WINDOW NO (E)W5 (E) 5"x5" I-BEAM WITH 2" CONCEAL BOX FOR PLUMBING VENT AND PROVIDE ACCESS FOR VENTING (E) 5"x5" I-BEAM WITH 2" CONCEAL BOX TO MATCH THE BOX TO BE FUSE UNDER THE BALCONY (N) ADDITIONAL HANDRAIL FROM THE EXISTING HANDRAIL (E) MECHANICAL SHAFT FOR THE HOOD SHAFT 1 2 LEGEND: 3 (N) OPEN SHELVES 4 5 -INTERIOR PANEL THAT ARE OLD WILL BE REPLACE BY NEW PANELS BOTH FLOORS IN DINING AREA. -NO CHANGE ON DESIGN IN THE EXTERIOR EXCEPT FOR THE REPAINT OF THE EXTERIOR WALL. NOTE: -FOR INTERIOR REPAIR ALL THE OLD DRY WALL WILL BE REPLACE BY NEW FIRE RATED DRY WALL IN THE DINING AREA FROM FIRST FLOOR TO SECOND FLOOR AS PER REQUIREMENTS. - REPAIR FLOOR TILE & COVED BASE AS NECCESSARY - REPAINT WHITE GLOSS FOR CEILING & WALL IN THE KITCHEN -THIS PROJECT IS NOT A CHANGE OF USE, THIS IMPROVEMENT OF THE RESTAURANT -NO CHANGES WILL BE NEEDED INSIDE THE KITCHEN STRUCTURALY. 2'-6" 3' - 4 " 6" 1'-6"4"8" LEGEND: HEIGHT UP TO 14'-0" BRACE LENGTH 10'-0" OR UNDER UP TO 12'-0" BRACE SIZE 2X4 STUD UP TO 18'-0" GYPSUM BOARD PLASTER / STUCCO WALL FINISH TYPES: 2x6 AT 20" O.C. 2x4 AT 24" O.C. 2x4 AT 24" O.C.2x4 AT 20" O.C. 2x6 AT 24" O.C. 2x6 AT 16" O.C. A B C D E FGH 2 ~ 16d COMMON NAILS (END NAILED ) PLATE TO OR USE 3 ~ (3" LONG ) 8d COMMON NAILS (TOE NAILED ). DOUBLE 2X TOP PLATE 2X WOOD STUDS (SEE SCHEDULE ) SEE ARCHITECTURAL FOR FINISH 5.5X.5 REDHEADS TIGHTENING BOLTS 4" TO CONCRETE SLAB @ 4'OC PRESSURE TREATED, OR FOUNDATION REDWOOD SILL PLATE 2 ~ 16d COMMON NAILS (END NAILED ) PLATE TO OR USE 3 ~ (3" LONG ) 8d COMMON NAILS (TOE NAILED ). CONCRETE SLAB FOOT RAIL A B C D E F G H I I 1/A2: (N) FLOOR PLAN, 1/4"=1' 2/A2: (N) SECOND FLOOR PLAN, 1/4"=1' NORTH NORTH DOOR DESIGNATION OPERATIONAL (E) D1 DOOR SCHEDULE SIZE 3'-0"x6'-8" (E) D3 4'-10"x6'-8" SOLID WOOD CORE DOOR , TIMELY FRAME (E) D2 SOLID WOOD CORE DOOR BARN DOOR (E) D4 4'-0"x6'-8" 5'-0"x6'-8"(E) D5 3'-0"x6'-8" (E) D6 3'-0"x6'-8"PVC DOOR (E) D7 3'-0"x6'-8" ALUMINUM EDGES, WITH SELF- REGULATING HEATING CABLES PANIC DOOR SOLID WOOD CORE DOOR BARN DOOR DOUBLE ALUMINUM EDGES, WITH SELF- REGULATING HEATING CABLES PROJECT TITLE: DATE: PROJECT DESCRIPTION: SHEET TITLE: DRAWN BY: YU C w V I Y d      . ʍ     9 2 6 6 1 ʍ  h ]  10 6  B  0 C  ] d Y   d 2 04-26-23 (N) FLOOR PLAN CLIENT / APPLICANT: DESIGNER / EXPEDITOR: RAMON BAGUIO 4273 CANOGA AVE WOODLAND HILLS, CA 310-562-5382 RBPLANDESIGN@GMAIL.COM WWW.CALPLANDESIGN.COM PROJECT ADDRESS: PROJECT CONTACT: Gegam Burnazyan MLB Consulting and Engineering 7918 Foothill Blvd, Sunland, CA (818)-521-6342 CIVIL ENGINEER (E) RESTAURANT PROPOSED (N) BAR (E ) R E S T A U R A N T P R O P O S E D ( N ) B A R 3/A2: (N) PONY WALL DETAIL, NTS TOTAL NUMBER OF SEAT DINING AREA 1: 43 SEATS & 13 TABLES DINING AREA 2: 28 SEATS & 13 TABLES 1ST FLOOR LEVEL CL'G PLATE T.O. BLDG 2ND FLOOR LEVEL CL'G PLATE 1ST FLOOR LEVEL CL'G PLATE T.O. BLDG 2ND FLOOR LEVEL CL'G PLATE 1ST FLOOR LEVEL CL'G PLATE T.O. BLDG 2ND FLOOR LEVEL CL'G PLATE 1ST FLOOR LEVEL CL'G PLATE T.O. BLDG 2ND FLOOR LEVEL CL'G PLATE F I R E W A L L REPAINT EXTERIOR WALL REPAINT EXTERIOR WALL REPAINT EXTERIOR WALL REPAINT EXTERIOR WALL REPAINT EXTERIOR WALL REPAINT EXTERIOR WALL REPAINT EXTERIOR WALL 23 ' - 4 " 23 ' - 4 " 23 ' - 4 " 23 ' - 4 " PROJECT TITLE: DATE: PROJECT DESCRIPTION: SHEET TITLE: DRAWN BY: YU Aɹ ɶɺ ʣ 2ɼ ʣ 2ɹ (E) ELEVATIONS CLIENT / APPLICANT: DESIGNER / EXPEDITOR: RAMON BAGUIO 4273 CANOGA AVE WOODLAND HILLS, CA 310-562-5382 RBPLANDESIGN@GMAIL.COM WWW.CALPLANDESIGN.COM PROJECT ADDRESS: PROJECT CONTACT: Gegam Burnazyan MLB Consulting and Engineering 7918 Foothill Blvd, Sunland, CA (818)-521-6342 CIVIL ENGINEER (E) RESTAURANT PROPOSED (N) BAR NE W P O R T B E A C . ʍ C A ɿ 2 ɼ ɼ 1 ʍ h S A 1ɶ ɼ B A I N S T R E E T (E ) R E S T A U R A N T P R O P O S E D ( N ) B A R FRONT ELEVATION 3/16"=1'-0 RIGHT ELEVATION 3/16"=1'-0REAR ELEVATION 3/16"=1'-0 LEFT ELEVATION 3/16"=1'-0 DRAINWATERPOWERFINISHDIMTYPE/MANUFFIXTURE FIXTURE SCHEDULE 2 3 4 (E) FLOOR MOP SINK FLOOR SINK 50% EXPOSED 2"D DIRECT DRAIN FD 6 (E) 3COMP SINK STAINLESS 1 2" OD CU. IND POTABLE WATER SUPPLY 7 8 (E) HANDSINK STAINLESS 12" OD CU. IND POTABLE WATER SUPPLY 2"D DIRECT DRAIN 9 11 13 14 15 10X14X5 103X24X44 18X18X13 COMP 16 17 19 18 10 (E) METRO SHLEVES STAINLESS18X48 12 (E) DOOR LOCKER 5 FLR SINK (N) FLOOR DRAIN 36"R AROUND TO SLOPE MIN 2% 2"D DIRECT DRAIN (N) ICE MACHINE (N) SODA GUN 29" X 24" X 24" 36 1 4" X 29 1 2" X 35 1 4" 15 1 2" X 30 1 4" X 47 1 8" 34" X 48" X 58" STAINLESS STEEL STAINLESS STEEL 208-230V 120V, 1 (N) COUNTER HEIGHT RFG (N) WARMING LAMPS (N) 36"X30'' RFG (E) FRYERS 20 (E) 4 BURNER W GRIDDLE (N)BAKERS PRIDE PIZZA (N) 3 COMP BAR SINK 57" X 66 1 2" X 43" 38 1 2" x 21" x 33" STAINLESS STEEL STAINLESS STEEL STAINLESS STEEL 1 2" OD CU. IND POTABLE WATER SUPPLY 2"D DIRECT DRAIN 2"D INDIRECT DRAIN TO 50% EXPOSED FLOOR SINK 1 2" OD CU. IND POTABLE WATER SUPPLY 2"D INDIRECT DRAIN TO 50% EXPOSED FLOOR SINK 12" OD CU. IND POTABLE WATER SUPPLY SELF CONTAINED (E) SANDWICH PREP 42 3 8" X 31"X 70 3 8"115V, 3.3AMPSSTAINLESS STEEL SELF CONTAINED (E) STEEL WORK TABLE 48" X 30"X 35 1 2"STAINLESS STEEL SELF CONTAINED47 1 4" X 29 1 2" X 35 1 4" STAINLESS STEEL STAINLESS STEEL 115V, 1.1AMPS 115V, 1.33AMPSSTAINLESS STEEL 31 15 16" X 13" X 23 13 16"ALUMINIUM 120V (E)AIRCURTAIN 20AMP, 110V36" (N) WATER HEATER NON-ELECTRIC 25" X 21" X 11 12"STAINLESS STELL 2"D DIRECT DRAIN (E) UTILITY SHELF W/ 2 MOP SINK (E) 1COMP SINK 115V, 4 AMPS GAS OPERATED GAS OPERATED NON-ELECTRIC NON-ELECTRIC NON-ELECTRIC NON-ELECTRIC NON-ELECTRIC NON-ELECTRIC NON-ELECTRIC NON-ELECTRIC NON-ELECTRIC NON-ELECTRIC NON-ELECTRIC 2"D DIRECT DRAIN 2"D DIRECT DRAIN 2"D DIRECT DRAIN 21212121 ..\..\..\RBCAS DROPBOX Dropbox\Ramon Baguio\RBCAS\106 MAIN ST, NEWPORT BEACH, CA SOCIAL PIES PIZZA\EQUIPMENT LIST AND SPECS\SPEC. SHEETS\WATER HEATER RAYPAK DELTA HD 151.png 55 FLOOR SINK DETAILINDIRECT DRAIN TO FLOOR SINK DETAIL 3 8"R COVE BASE DETAIL DRAWN BY: YU A4 04 - 26 - 23 SPEC SHEETS. ALL FIXTURES ARE NSF OR ETL APPROVED PROJECT TITLE: PROJECT DESCRIPTION: SHEET TITLE: C w V I Y d   A  . ʍ  A ɿ 2 6 6 ɷ ʍ h ] A ɷ0 6 B A 0 C ] d Y   d DATE: CLIENT / APPLICANT: DESIGNER / EXPEDITOR: RAMON BAGUIO 4273 CANOGA AVE WOODLAND HILLS, CA 310-562-5382 RBPLANDESIGN@GMAIL.COM WWW.CALPLANDESIGN.COM PROJECT ADDRESS: PROJECT CONTACT: Gegam Burnazyan MLB Consulting and Engineering 7918 Foothill Blvd, Sunland, CA (818)-521-6342 CIVIL ENGINEER (E) RESTAURANT PROPOSED (N) BAR (E ) R E S T A U R A N T P R O P O S E D ( N ) B A R