HomeMy WebLinkAboutXR2023-0488 - MiscCITY OF NEWPORT BEACH COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION 100 Civic Center Drive I P.O. Box 1768 i Newport Beach, CA 92658 www-newportheachca.gov i (949) 644-3200 SPECIAL INSPECTION REPORT Project Address: Storage Addition. 22 Encore Court, Newport Beach, CA Permit Number: XR2023-0488 Inspection Type Chemical Anchors Inspection Date (s): 6/13/23 F]Periodic RIContinuous Observed the placement of #4 reinforcing steel dowels at storage area slab on grade per details A & B on sheet S1. Placement using Simpson Set XP epoxy- (Lot #1000322314, exp 12124). Prior to placement verified min embed and proper cleaning of holes using nylon brush and compressed air. Total Inspection rime Each Day: Date: 1 6/13123 Hours: 1 Min Other than any noted discrepancies all work was done per approved plans, job site specifications, applicable codes, RFI's and WPS's to the best of my knowledge and appeared to be in compliance at time of inspection. Special Inspector Signature: Date: 6/13123 Print Full Name: Newport Beach Registration No.: Peter Gilpin NB-0381 Specialimpecdonfleport 8- 24-15 CITY OF NEWPORT BEACH COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION 100 Civic Center Drive I P.O. Box 17681 Newport Beach, CA 92658 www.newr)ortbeachea.gov 1 (949) 644-3200 SPECIAL INSPECTION REPORT Project Address: Storage Addition. 22 Encore Court, Newport Beach, CA Permit Number: XR2023-0488 Inspection Type (s): Keinforc Inspection Date (s): 6/19/23 steel Periodic I (Continuous Verified the reinforcing steel placement at slab and footings for crawl space. Details A -A & B-B. Rebar was verified for size, lap, location and clearance. Total Inspection Time Each Day: Date_ T 6/19/23 -- --------- Hours: I Min list All Items Requiring Correction (Include Previously listed Uncorrected Items): Other than any noted discrepancies all work was done per approved plans, job site specifications, applicable codes, RR's and WPS's to the best of my knowledge and appeared to be in compliance at time of inspection. Special Inspector Signature: Date: P~I 6/19/23 Print Full Name: Newport Beach Registration No.: Peter Gilpin NB-0381 Speciallnspection Report 8-24-15 m Cp 301 m Z Z m a G3 N u O 0 m z z NUIUH HJ IRLULU C x a m D m m r D Z s CITY OF NEWPORT BEACH COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION 100 Civic Center Drive I P.O. Box 1768 1 Newport Beach, CA 92658-8915 www.newportbeachca.gov 1 (949) 644-3200 SMOKE DETECTOR AND CARBON MONOXIDE SELF -CERTIFICATION (this certification is to be filled out by the permittee or homeowner) Project Address: ;rn o r Permit Number:"ba",- OLk�_Sl Property Owner: jPFp <V2q d�� Licensed Contractor: fMUA�. '(1cC L Lic#: 7(% / _ The State of California now requires that smoke and carbon monoxide detectors must be installed in all residential buildings California Residential Code (CRC) Section R314.1, CRC R315.2 states in part that existing dwellings be "retrofitted with smoke detectors and carbon monoxide detectors. CRC Section R314.3, CRC R315.3 defines required locations. Both boxes below must be checked: Carbon Monoxide Alarm: On the ceiling or wall outside of each separate sleeping area in the immediate vicinity of bedrooms or in each hallway outside of the rooms, and each level of the dwelling. Detectors are also required in bedrooms with gas fired appliances Smoke Alarms: Installed in each room used for sleeping purposes, outside each sleeping area, and on each level of the dwelling unit. Retrofitted detectors may be battery operated for buildings where no alterations are performed on the interior. Multiple -purpose alarms (carbon monoxide and smoke alarms) shall comply with all applicable standards and must be approved by the State Fire Marshall. The devices must be installed per manufacturer's specifications. I, the undersigned, hereby certify that 1 am the permittee or homeowner of the project. I further c rtify that smoke alarms and carbon monoxide alarms are present and t s ed td he functional in all the following locations: Signature: Date: Z3 NOTE: This #elf-dification is only used for projects to the exterior of the structure where access to the interior of the dwelling by the C@y of Newport Beach Building Inspector is not achieved during the course of construction. FormskSmokeDefec arandCarbonMonoxideSelfCetl 08/12/16