S2023-0068 - Misc
`)ZDz8 - ©o\"-V 4ke A6-2�Pt CITY OF NEWPORT BEACH COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION 100 Civic Center Drive I P.O. Box 1768 Newport Beach, CA 92658 www.newportbeachca.gov (949) 644-3200 SPECIAL INSPECTION REPORT Project Address: Dusablon Pool/Spa. 416 Hazel Drive, Newport Beach, CA Permit Number: S2023-0068 Inspection Type (s): Shatcrete Inspection Date (s): 6/8/23 ❑Periodic Continuous Describe Inspection, Including.Location(s): Observed the pneumatic placement of 25 cubic yards of shotcrete at rear of residence Spa & pool. Prior to placement verified clearances at previously inspected reinforcing steel Nozzelman was observed for proper application procedures. One set of 4 test samples was taken - ticket #7634352, slump 3", PSI 4500, shotcrete temp 72F. Total Inspection Time Each Day:' Date 7 Hours:Min List All Items Requiring Correction (include Previously Listed uncorrected items): Comments: 1 Other than any noted discrepancies all work was done per approved plans, job site specifications, applicable codes, RFI's and WPS's to the best of my knowledge and appeared to be in compliance at time of inspection. Special Inspector Signature: Date: j 6/8/23 Print Full Name: I Newport Beach Registration No. Peter Gilpin i NB-0381 SpeciallnspectlonReport 8-24-15 23/235 CHRISTOPHER JEAN & ASSOCTATESi INC. ACOUSTICAL CONSULTING SERVICES November 8, 2023 MR. DAVID PENTON 1101) DYNAMICS POW 720 E. Walnut Avenue, Suite A Full Eton, CA 92831 SUBJECT; Dear Mr. Penton'. Business License: OBT30044674 We are pleased to inform you that the pool equipment Installation located at 416 Hazel Drive m* the City of Newport Beach complies with the City's 55 dBA noise limit. No additional noise mitigation is necessary. The installation was measured on Wednesday, November 8,2023,using a Larson Davis Model 700 Type 2 Sound Level Motor. The installation was observed to consist of two Pentair Intellitlo pumps, one Pentair Whispa-flo pump, and a, Mastortemp 400 heater, All t1wee pumps were located in a filly enclosed closet beneath a staircase, Measurements at the north and south prop" lines in view of the closet doors reported levels below the background ambient of 50 dBA with all three pumps operating. Tho heater unit was remotely ,located In a side yard. A measurement just over the top of the nearest property line wood fences directly opposite the heater unit. This measurement reported a level of 51 dBA with the heater unit operating. All of the measuredlevels comply with the CitY's 55 dDA noise limit. Thank you, , and if there are any questions, please do not hesitate to call. by: L—.- Mdent BOX 2325 FULLERTON, CALIFORNIA'- 92837 PHONE. 714-905-0115