HomeMy WebLinkAboutM2023-0040 - MiscReport of Special Inspection
Pmjcct N Add... Alan SChnllf, 34e is Lido Nord
Number
Type(s) Marine Piles
Inspection
Describe Inspection Made, including locations:
77 Continuous
Marine Piles
Scope of work - Remove and Relace Piles with new at the Pier & Platform and to
Relocate Piles at the Floating Dock.
Observed the placement of concrete marine piles per schedule and details on
the approved plan. Schedule on sheet S-2 and details on sheet S-3. Piles
installed by way of water jetting.
Locations: Boat Dock
Piles # 1 & 2 = 14"sq. x 21' Long, with min. 15' ft. embed.
Piles # 3 & 4 = 14"sq. x 30' Long, with min. 15' ft. embed.
Pile # 5 = 14"sq. x 34' Long, with min. 15' ft. embed.
Locations:
1) Pile #1 installed today.
2) Pile #2 installed today.
Work is complete for the areas listed.
List Tests Made
Total Inspection Time Each Day:
List Items Requiring Correction, Include Uncorrected Items Previously Listed:
To the best of my knowledge, the wnrk inspected was in accordance with the Building Department
approved design drawings, specifications and applicable workmanship provisions of the IBC except as
noted above.
9-28-23
Jon Newsom n-;,t-„,,,,U„ NB-0303
FORM S1 02, :"H
Report of Special Inspection
Pmjee, Name & Add..." Alan Schnur, 642 Via Lido Nord
Permit Number
Inspection Type(s) Marine Piles �jj
Inspection Dates) 9-29-23 I V (Periodic Elcontinuous
Describe Inspection Made, including locations:
Marine Piles
Scope of work - Remove and Relace Piles with new at the Pier & Platform and to
Relocate Piles at the Floating Dock.
Observed the placement of concrete marine piles per schedule and details on
the approved plan. Schedule on sheet S-2 and details on sheet S-3. Piles
installed by way of water jetting.
Locations: Boat Dock
Piles # 1 & 2 = 14"sq. x 21' Long, with min. 15' ft. embed.
Piles # 3 & 4=14"sq. x 30' Long, with min. 15' ft. embed.
Pile # 5 = 14"sq. x 34' Long, with min. 15' ft. embed.
Locations:
1) Pile #'s 3 & 4 installed today.
Work is complete for the areas listed.
List Testa Made
Total Inspection Time Each Day.
Date
Hours
List Items Requiring Correction, Include Uncorrected Items Previously Listed:
To the best of my knowledge, the work inspected was in accordance with the Building Department
approved design drawings, specifications and applicable workmanship provisions of the 113C except as
noted above.
9-29-23
Signed: ; 7X %��%ram �"� Date:
Print Full N/ai»e: Jon Newsom Registration No. NB-0303
room s,ww. E"o
Report of Special Inspection
project Name & Address Alan Schnur, 642 Via Lido Nord
Permit Number IV lMT 5- 0vAQ
Inspection Type(s) Marine Piles
Inspection Daic(s) 10-2-23 7yeriodic ❑Continuous
Describe Inspection Made, including locations:
Marine Piles
Scope of work - Remove and Relace Piles with new at the Pier & Platform and to
Relocate Piles at the Floating Dock.
Observed the placement of concrete marine piles per schedule and details on
the approved plan. Schedule on sheet S-2 and details on sheet S-3. Piles
installed by way of water jetting.
Locations: Boat Dock
Piles # 1 & 2=14'sq. x 21' Long, with min. 15' ft. embed.
Piles # 3 & 4=14"sq. x 30' Long, with min. 15' ft. embed.
Pile # 5 = 14"sq. x 34' Long, with min. 15' ft. embed.
Locations:
1) Pile #5 installed today.
Work is complete for the areas listed.
List Tests Made
Total Inspection Time Each Day:
Date
Hours
List Items Requiring Correction, Include Uncorrected Items Previously Listed:
To the best of my knowledge, the work inspected was in accordance with the Building Department
approved design drawings, specifications and applicable workmanship provisions of the IBC except as
noted above.
10-2-23
Print FpdName: Jon Newsom Registration No. NB-0303
Foam sw±.:nu
Report of Special Inspection
Project Name & Address Alan Schnur, 642 Via Lido Nord
Permit Number
Inspection Type(s)
Marine Piles
Inspection Date(s) R/C ❑Periodic W611tifluous
Describe Inspection Made. including locations:
Epoxy
Observed the installation of rebar dowels per schedule and details on the
approved plan. Verified the hole depths and proper cleaning with a nylon brush
and compressed air prior to the epoxy. Type of epoxy used Simpson xp, ESR
2508, expiration 2024. Schedule on sheet S2,
Details on sheet S-4 / K.
Location:
1) Pile Cap S-4 / K = (2) 5/8" threaded rods with min. 6" embed. Two per pile cap
2) Sea Wall Ledger = 4" x 8" Ledger with (4) 5/8" threaded rods with min. 6"
embed.
Work is complete for the areas listed.
List Tests Made
Total Inspection Time Each Day:
Date
Hours
List Items Requiring Correction, Include Uncorrected Items Previously Listed:
To the best of my knowledge, the work inspected was in accordance with the Building Department
approved design drawings, specifications and applicable workmanship provisions of the IBC except as
noted above. e
10-9-23
Print Fu4Name: Jon Newsom Registration No. NB-0303
FURM SI-62.:014