HomeMy WebLinkAboutXR2023-2456 - Alternative Material & MethodsXCLGD2�"ZLiS� o�ai�
��EWPpRT CITY OF NEWPORT BEACH
O 6
COMMUNITY DEVELOPMENT DEPARTMENT
u n S BUILDING DIVISION
100 Civic Center Drive I P.O. Box 1768 1 Newport Beach, CA 92658-8915
9<rFOA�� www.newoortbeachca.ciov 1 (949) 644-3200 6n_
cy
CASE NO.: fi'i.1
❑ REQUEST FOR MODIFICATION TO PROVISIONS
OF TITLE 9 (FIRE CODE) OR TITLE 15 (BUILDING CODE)
OF THE NEWPORT BEACH MUNICIPAL CODE
(See Reverse for Basis for Approval) (Fee $306)
® REQUEST FOR ALTERNATE MATERIAL
OR METHOD OF CONSTRUCTION
(See Reverse for Basis for Approval) (Fee $306)
For above requests, complete Sections 1, 2 & 3
below by printing in ink or typing.
JOB ADDRESS:
III FOR STAFF USE ONLY III
Plan Check # II
# of Stories _3
Occupancy Classification
Q3
Use of Building
# of Units
Project Status OIAI1
Construction Type �'._���
Verified by IL �{
No. of Items
Fee due
DISTRIBUTION:
�-
Owner
Plan Check Z•Z,
Petitioner
❑ Inspector
❑ Fire
❑ Other
9�dY1G]:I�:A
SITE ADDRESS: 439 Harbor Island Dr. Petitioner Brandon Architects - Nicole Thompson, AIA
Owner Trust of the Fletcher Family (Peffdoner M da acdttea or a gfneey
Address 151 Kalmus Dr., Suite G-1
Address 290 Wooded View Dr. Costa Mesa, CA Zip 92626
Low Gatos, CA Zip 95032
Daytime Phone ( 408 ) 961-8125 Daytime Phone C754-4040
Email: nicole@brandoandonarchitects.com
L REQUEST: Submit plans if necessary to illustrate request. Additional sheets or data may be attached.
Alternate maximum travel d stance for emergency escape and rescue opening onto a root/deck, The pro act s
proposina a maximum travel distance of 8' - 5" instead of 5' - 0" from the center of the operable portion of the EE&RO
of Bedroom #2 to the front yard.
3[JUSTIFICATION/FINDINGS OF EQUIVALENCY: CODE SECTIONS:
The roof/deck that Bedroom #2 � erregg no onto s a 1 hr rated floor/ced no CRC R310
assembly with class 'A' rating and is s rindered. The 1-hr rated assembly exceeds the rating that would be required
for egress onto a roof/deck with a 5' - 0" maximum travel distance. The additional protection of the 1-hr rated
assembly will ensure sae egress wit the additional T- ' of travel istance.
Petitioners Position Project Architect
Signature k- CA Professional Lic. # C-39925 Date'. 11 .07.23
FOR STAFF USE ONLY
�
DEPARTMENT ACTION: In accordance with: ,E4 CBC 104.11/CFC 104.9
(Alternate materials & methods)
❑ Concurrence from Fire Code Official is required. ❑ Approved ❑ Disapproved
/--:_^-�-- -,� By: Date
Request (DOES) i OES NOT) le on any fire protection requirements.
quest (DOE lessen the structural integrity
❑ CBC 104.10/CFC 104.8
(CBC Modification)
❑ Written Comments Attached
The Request is: I?T'Zranted ❑ Denied (See reverse for appeal information)
❑ Granted (Ratification required)
Conditions of Approval:
Signai �^-l- - � �� PositidSHIEF BIM DINSf1FFif4AI-Date
Print Name
c �— ZciL
APPEAL OF DIVISION ACTION TO THE BUILDING BOARD OF APPEALS (See Reverse)
(Signature, statement of owner or applicant, statement of reasons for appealandfiling fees are required.)
CASHIER RECEIPT NUMBER: fiSL - Ol9SVN d- f/V 23 Formslmodif 08/21123
MOD - EE&RO PLAN
DATE: 11/07/23
PROJECT: FLETCHER BEACH HOUSE
ADDRESS: 439 HARBOR ISLAND DR.
NEWPORT BEACH, CA 92660
SECOND LEVEL ENLARGED PLAN
BRANDON
1
A-5.1
DOOR TO MEET EGRESS '
REQUIREMENTS I
I
I
I
I
BRANDON ARr- I'll 1/,,.,.I 1. "(1", -1, , ;nao
O
o unx�
O O OIL
w
i' T. moan
eoen wrvio-nx ois wu
e (]
® arr.mu '^'®xe^°enwm.wnu rw wq,
BRANDON ARCHRECTS
11 :m uu�s`-al�ITT
E�meNvaai�myaninvmi
FIRST LEVEL FLOOR PLAN
l-.e e�x —-ax.� xn,
^ xµ,^,.m...e.w
n,w I w- x
s Y1-1 .1 IT—
8
�., � 'L w w� LITI- z�'
d
m ,.... LL.x
mrvw n
taro ru
x
- FIRST LEVEL FLOOR
PLAN
oe
uwus o eto
�
t+irm.ry uuxew.w.nn®.wsrcx — x
pPEI
I 1
�® G
sure
O
nmr
os-srWueM arcr xxxm.�u wu[enw n
memnsewuw wo xnuuo xrmux mmsxen usx
A-2.0
B � KEYNOTES
A I ANNOTATON LECENO
® .ure en m.man-nrr ous�w.n
" C31
® vx. mm er nnmm wmwr nuxmum,w w.
,.,,„m wrtmn LEE. 1. u eLe
.v.mumru E,m 1m TEI III 'Ell ➢0,%L 1z DIll .x
,w v„r
71E
I
I
I
I
1
I
�SFCONNIFVFL FLOOR PIAN
'ET- ELEEIlLIEFLIETELI11
NRWIDON ARCHITECTS
v.mr,xomvwry
W
h
O
S
S
t)
Q
w
m
w
S
cE-
H
W
J
LL
FRwou:::
SECOND LEVEL
FLOOR PLAN
A-2.1
B I KEYNOTES I A I ANNOTATION LEGEND
INK
r.J'a8 TST��:e�E�ll
q,Yr'^!�� �, n!�nn�in� �r�il ���MBtl�
p > G
m
i®ritm.
I ��s
NMI
rsw..rswN..w,._.,.,,,u.,,,w.a,
`I
rsornzswiars.xw�uoi.,.rsue..wsmwaww.xi,uunx.
=1
,�uzzzw.,.v
BRANOON ARCHITECTS
aasxurs ersixnurs:o. ILK- .s,.x.iuITT' xuVxizI'll ow.srswsau.KIN urs.+,x
Is,xunus owrtsI
uu
.. oww xsxs,.w esx x,w..z won... TNNzixaix, m,x,.avusw ns
MI
I
—Tmou
I.MINT-TTINNIN.-.A.W,s..rzrsr.,.rcmrs. osurnw „ars.»z
w-1INNN,r.wsssu,,K, NNa—..».Na,...eun.ssw,wusx.s
zA
NMI
_r
I FIRE -BLOCKING& DRAFT STOR NOTES
eo eaxo.
I
c
WKE THOM A
,lam
w,ruuex T.NN,nrwouovwrm,w«ruxwuwuunm..NN MS rw —,
_.
INSULATION SCHEDULE
m
fl00M X.aMIE
.vnm�unuurcrnn
W
LONGITUDINAL SECTION1z
N
p
O
000
0
=
t�
a
0
W
m
— .� KI u_
W
C®TATION LEGEND
UJ
— ;,�
J
rsrso
MI T
—,wwwow�ac.aviceomrv..nnxm.
oerwnuI.x,TINo.,rm—,u._..wff..,
IN -
U—
,T.o KOOK
X.oXEp,
..
KDNNI
.wumvraaou
� w,x»o�.TNT_
BUILDING SECTIONS
%n1 iRAYSVERSE S[E➢OIJ
G
LD1111
A-5.1
BWDON ARCHITECTS
wvxnc.. �wauuo
O,.l2l
��� weep SCREED C,