HomeMy WebLinkAboutPARKING SPACES-FAR11111111111111111111111111111111
*NEW FILE*
PARKING SPACES - FAR
TO:
FROM
SUBJECT:
CITY OF NEWPORT BEACH
BUDLDrNG bEPARTMENT
June 15, 1970
LARRY WILSON, PLANNING DIRECTOR
Building Director
FLOOR AREA IN RELATION TO REQUIRED PARKING SPACES
Although I can't find any copy of the memo from Daren Groth about the above
subject, I am afraid that I go along with the I.C.B.O. definition and Bob
Fowler's opinion of how this should be handled..
In determining the square feet of floor space per occupant as to use of
area or building, of necessity, it is d general filg'ure which has been worked
out over the years. This is evident when one refers to the 1952 edition of
the Uniform Building Code where the table regarding this subject first ap-
peared with a total of only twelve (12) occupancy classifications. As it
became evident over the subsequent years that the classifications were too
general, it was broken down into more specific categories so that in the
1970 edition there are 23 main categories and 15 sub -categories.
We all recognize that probably no two uses are exactly alike in operation
so a general figure has to be developed. We also must recognize that oc-
cupants change and along with this even the way an individual company op-
erates also changes. From these two facts it is obvious that it is dangerous
to set up an exception to this general regulation to fit a specific operation
which is out of the normal, scope in its specific operation. By this I am
referring to the probability of its changing as another occupant comes along
with a corresponding different method of operating. It would be an impossible
changing condition to follow and revise for each change.
We must recognize that these general figures include the attendant facilities
or uses under each category such as restrooms, halls, lobbies, stairways,
elevators, storage rooms, mechanical rooms, etc., as well as the fact one
occupant will have more desks, filing cabinets and furniture than another.
One may have more deluxe and larger restrooms than another but the average
should and usually will remain about the same.
From the above explanation plus the danger of the changing opinions which come
with each change of personnel, I feel quite strongly that we should stick
quite closely to tha definition of "floor area" as published in the Uniform
Building Code as the standard we fol'lo_L_v this matter.
OSG:pf
xc: E. Cich
Bob Fowler
Bob fttch
REDEIVRD ,
PLANNIm DOT,
jUN1.6197OW
cot O
11M 0 1F,
e; � e�- " �/,, �
OLIVER S. GRANT
y CODE 1970 EDITION SECTIONS 407.408 r
and TIRE RESISTANCE or FIRE -RESISTIVE CONSTRUC- Definitions
;din TION is construction to resist the spread of fire, details of (Continued)
fiam
e ver-
C plant
•4t by
which
r'ad of
.insion
1Xon-
{tr sky,
�{ on
„
sf the
5� and
p_:ests.
n{tich
Hotel"
o `e b
" 1 to be
spied,
,'which
spied
Band
T
Exist-
1 wits
,[an five
tnd by
which are specified in Chapters 42 and 43 of this Code.
FIRE -RETARDANT TREATED WOOD is lumber or ply-
wood impregnated with chemicals and when tested in accord -
mice with U.B.C. Standmd No. 42-1 for it -period of 30
minutes shall have it flame spread of not over 25 and show no
evidence of progressive combustion. The fire -retardant prop-
erties shall not be considered permanent where exposed to the
weather.
All material shall bear identification showing the fire per-
formance rating thereof issued by an approved agency having
a re-examination service.
FLOOR AREA is the area included within the surrounding
exterior walls of a building or portion thereof, exclusive of
vent shafts and courts. The floor area of a building, or portion
thereof, not provided with surrounding exterior walls shall be
the usable area under the horizontal projection of the roof or
floor above.
rf)nTTNC ie thai• n.rfinn of hha fmmrintinn of n strnrhire
which spreads and transmits loads directly to the soil or the
piles.
FRONT OF LOT is the front boundary line of a lot bor-
dering on the street, and in the case of a comer lot may be
either frontage.
Sec. 408. GARAGE is a building or portion thereof in G
which a motor vehicle containing gasoline, distillate or other
volatile, flammable liquid in its tank, is stored, repaired, or
kept.
GARAGE, PRIVATE, is it building, or a portion of a
building, not more than 1000 square feet in area, in which
only motor vehicles used by the tenants of the building or
buildings on the premises are stored or kept. (See Section
1501.)
GARAGE, PUBLIC, is any garage other than a private
garage.
GRADE (Adjacent Ground Elevation) is the lowest point
of elevation of the finished surface of the ground between the
exterior wall of a building and a point 5 feet distant from said
wall, or the lowest point of elevation of the finished surface of
the ground between the exterfor wall of a building and the
property line if it is less than 5 feet distant from said wall. In
case walls are parallel to and within 5 feet of a public side-
walk, alley or' other public way, the grade shall be the eleva-
tion of the sidewalk, alley or public way.
37
V
,
�I 1
I �
i
i
_ , i. ','i., '1i� •��,i.•1!Mr''i:":ri .'�' '?, r,',, 1;�. i:T� � - :'rJ ,,�,.'.I,. ?�., •�?"r ,
'. i"�'f, '�'� .,.' :, ;fir •,�•>? '+'�:.�i�4 ;";'.,'; `�.
Builders of Tomorrow's Cities ... Today
July 24, 1970
Mr. Larry Wilson
Planning Director
City of Newport Beach
3300 Newport Boulevard
Newport Beach, California 92660
Dear Larry:
NEWPORT BEACH ZONING CODE PARKING REGULATIONS
Y �.4t°
Ric N���Qj
Q�p,NN �g1�0
\ NE�POSp�,tE• ��
As per our conversation several weeks ago, The Irvine Company
staff has reviewed criteria relative to determining areas
within commercial structures that should require off-street
parking. Following are the conclusions and recommendations
of our staff to the city for consideration during the course
of your study of this matter.
1. Definition of Terms
The definition of terms used in the zoning code should
be consistent with definitions used in the Uniform
Building Code as adopted by the City of Newport Beach.
The 1967 Uniform Building Code Section 407 defines
"Floor Area" as follows:
"That area included within the surrounding
exterior walls of a building or portion thereof
exclusive of vent shafts and courts. The floor
area of the building or portion thereof not pro-
vided with surrounding exterior walls shall be
the usable area under the horizontal projection
of the roof or floor above."
Since potential occupant load of a building has a direct
relation to the number of parking stalls needed, the
U.B.C. method of determining occupant load areas should
be applied in determining parking. Section 3301 of the
U.B.C. permits deduction of accessory use areas which
The Irvine Company • 550 Newport Center Drive • Newport Beach, California 92660 • (714) 644-3011
N
2.
ordinarily are used only by.persons who occupy other
main areas of the same building. Therefore, it is
the recommendation of The Irvine Company that in deter-
mining required parking, the building area used should
be "Floor Area" as defined by the U.B.C. less certain
qualified accessory areas.
2. Accessory Use Area
The Irvine Company has examined accessory use areas or
areas which do not contribute to the occupant load of
the building and have determined that the following
appurtenances should be excluded from calculation of
required parking.
A. General Offices
Items of exclusion; stairwells and shafts, janitorial
closets, toilet room facilities, mechanical and
electrical shafts and equipment rooms, and elevator
lobbies not used as occupied office space.
B. General Retail Stores
Items of exclusion; stairwells and shafts, janitorial
closets, toilet room facilities, mechanical and
electrical shafts and equipment rooms, mezzanine
storage areas, and walk-in cooler and refrigerator
areas.
C. Restaurants
Items of exclusion; stairwells and shafts, janitorial
closets, toilet room facilities, mechanical and
electrical shafts and equipment rooms, kitchens,
storerooms and receiving areas, walk-in cooler and
refrigeration areas.
The above information is the result of a review by those persons
in the company experienced with the construction and management
of general offices, high rise offices, retail and specialty
commercial developments. It is the opinion of The Irvine Company
that the appurtenances listed as accessory areas to be excluded
from parking requirements are justified by the experience of
the company in the development and operation of existing
facilities and the experience of architectural and engineering
consultants working for The Irvine Company on other commercial
and office projects. The company is vitally concerned with
i
3.
this subject since it will affect many of our projects and
would, therefore, request that we be kept apprised of the
status of this study by the City of Newport Beach and where
possible, to provide additional information and comments.
We sincerely appreciate the opportunity to submit this recom-
mendation to you and be asked for comments relative to the
study. Should you have any questions regarding the information
submitted, do not hesitate to contact me directly.
Sincerely,
James E. Taylor
General Planning Administrator
eb
cc: P. Hughes
T. Welsh
D. Kaylor
R. Stone
J. Carter
C. Keyzers
CITY OF NEWPORT BEACH
BUILDING DEPARTMENT
May 29, 1970
TO: LARRY WILSON, PLANNING DIRECTOR
FROM: Planchecking Engineer
SUBJECT: ZONING CODE INTERPRETATION OF SQUARE FOOTAGE
The Newport Beach Zoning Code requires parking based upon floor area.
We have reached a dilemma in enforcement of the parking ordi-nance. The
Zoning Code does not define "floor area." The Building Code defines
"floor area" as:
"The area inside of the exterior walls, exclusive of elevator
shafts, vent shafts, etc."
We (Building Department) have been requiring parking based upon floor
area definition as defined ft the Uniform Building Code. We have run
into a situation with the Irvine Company in Newport Center where earlier
a definition of "floor area" was given (verbally) excluding corridors,
elevators, lobbies, rest rooms, vent shafts, storage areas, etc. If
this is indeed the policy which the Planning Department wishes to en-
force, we would apprecl`a.te a written -memo so directing, otherwise we
will enforce the Building Code definition of floor •area and require
parking based upon the Zoning Code and the computed area,.
OSG:BF;pf
xc: Building Director
Assistant Building Director
Planchecking Engineer
Building Plans Inspector
yr gosIVED
,wi nllR Do.
MAY 2 9 gow
i
- -- - ----------
h
�(- - ---
i
--/fir
u5C
Floor
Basement
1st Floor
Typical Floor
19th Floor & Roof
1. Irvine Tower #3
EXHIBIT "A"
SECTOR 600 PARKING
Irvine Tower #3 Floor Area
Gross
20,800 sq.ft
12,359
272,034
(17 @ 16,002)
15,376
320,569
Non-Contrib:, Net
. 13,291 sq.ft. 7,509 sq.ft.
2,489 9,870
45,373 226,661
(17 @ 21669) (17 @ 13,333)
15,376 0
76,529 244,040 sq.ft.
Parking Requirements
244,040 sq. ft. Net @ 1 space
per 250 sq. ft. .... 976 spaces
2. Balboa Building
Code per W.B.&A................................. 774 spaces
3. Parking Structure "A"'
.14,000 sq. ft. of which 8,500 sq. ft. = 350
seats for Dining (15 sq. ft. per sear = 567
per Code), 1 space per 3 seat .................... 117 spaces
4. Parking Structure "B"
14,000 sq. ft. Shops @
1 space per 250 sq. ft. 56 spaces
I Total Parking Required ........................ 1,923 spaces
9
* Per Skip Keyzers
- 1 -
-
�I
Parking Available - Scheme B-1
(Using Compact Stalls in Parking Structure "A")
1. Parking Structure "A"
2. Parking Structure "B"
3. Balboa Basement
4. Union Plaza
5. Balboa Plaza
Total Available
Total Required
Excess Above Code
Required for Duplicate of Bldg. #3
Balance to Surface Park
Standard
Compact
12009 stalls
105 stalls
1,332
12
49
17
17
2,424 stalls
117 stalls
1,923
0
501 stalls
117 stalls
976
475 stalls
Area Required @ 400 sq. ft.
per Stall ...................... 188,000 sq. ft. or 4.3 acres
Parking Available - Scheme B-2
(Using All Standard Stalls)
1. Parking Structure "A"
2. Parking Structure "B"
3. Balboa Basement
4. Union Plaza
5. Balboa Plaza
Total Available
Total Required
Excess Above Code
Required for Duplicate of Bldg. #3
Balance to Surface Park
15108 stalls
1,332
49
17
17
2,523 stalls
1,923
600 stalls
976
376 stalls
Area Required @ 400 sq. ft.
per Stall ...................... 150,400 sq. ft. or 3.5 acres
- 2 -
------ - - - -----
I'
-------------------------------------------- -----
---- ---
-
-
--
-
--
------------------
I
_
_
CITY OF NEWPORT BEACH -- PLANNING DEPARTMENT
TO: L. Wilson
FROM; W. Foley
SUBJECT; Memo from Bob Fowler
About a year ago Daren Groth sent a memo to the Building
Department which defined floor area for purposes of
calculating parking requirements. (Copy attached.)
The Buildi.ng Department feels that lobbies, corridors, etc.
should be included in the floor area.
Do we want to stick with Daren's interpretation or should
we be more strict, i.e. follow the UBC's definition?
June 1, 1970
IGNATURE W. R. Foley
Zoning Inspector
CITY OF NEWPORT BEACH
BUILDING DEPARTMENT
DEPARTMENTAL MEMO 70-17
November 6, 1970
TO: BUILDING DEPARTMENT STAFF
FROM: Building Director
SUBJECT:. CALCULATIONS FOR REQUIRED PARKING
.-
Until such time as specific written instructions are provided by the Planning
Department/Planning Commission, the area of the building to be used to calcu-
late the number of required parking spaces will be the entire building minus
vertical shafts and elevator shafts.
xc: Planning Director
OSG:pf
A
OLIVER S. GRANT
m
n
t.. I fn l.. mlII1.
b Nrrrrn; p f o
PT.
£ Nov 6 19?0
QIIY
. NEWPORP �F •'C
Z, OAIIF. P/!Oy
rs �A