HomeMy WebLinkAboutGB070010_Correction ListCounty of Orange
OC Public Works
Building Permits Division
Main Office
300 N. Flower Street
Santa Ana, CA 92702-4048
GB070010 Plan Check Corrections
Corrections shall be made on the tracings and three(3) new sets of plans shall be submitted. If you make changes to the
plan other than or in addition to what Plan Check has requested, yellow highlight the changes on one set of the re-submitted
plans.
Return the original check print with corrected plans. Payment of a new plan check deposit may be required for all plans
on which no action is taken by the applicant for a period of 180 days. Applications for which no permit is issued within
180 days following the date of submittal shall expire by limitation, and shall be discarded.
Project Number:GB070010
Submittal Date:Oct 12, 2010
CBC Edition: 2000
Plan Check Date: 10/25/2010 4:05 PM
Description:precise grading
for two sfd
Job Address
15 AVALON VISTA
NEWPORT COAST, CA
Owner Address
TUSHAR PATEL FAMILY TRUST
33 CANYON TERRANCE
NEWPORT COAST CA92657
1st Plan Check 2/6/07 1st Recheck 7/10/07 2nd Recheck 8/22/07 1st Revision 6/5/08 1st Recheck 6/18/08 Current - 2nd
Revision 10/25/10
Plan Checked By
Michael Fisher
Michael.Fisher@ocpw.ocgov.com
(714) 667-8868
(714) 667-8885 FAX
Contact Address
Krishna B Bhakta
30 Hughes
STE 202
Irvine CA92618
949-206-0509 x203
krishna@nathudevelopment.com
Page 1 of 4
GB070010
GENERAL INFORMATION
Please provide 24-hour notice to your plan checker, prior to obtaining the grading Permit.Return the original check
print with corrected plans. Payment of a new plan check deposit may be required for all plans on which the applicant
takes no action for a period of 180 days. Applications for which no permit is issued within 180 days following
date of submittal shall expire by limitation, and shall be discarded.
SUBMITTALS, FEES, BOND, INSURANCE AND ISSUANCE
Provide three (3) complete sets of corrected plans. Provide minimum 40-scale plan for precise grading. The maximum
size shall be 36" x 42". All sheets shall be uniform size. Plans will not be rechecked at the counter. Allow
one week for recheck.
Plan check and inspection deposit amounts will be calculated by the plan checker based on earthwork quantities
or drainage improvements, whichever is greater. The engineer shall provide this information.
Surety is required in the amount of $ _________. Surety may be posted in one of the following forms:
Bond
Certificate of Deposit
Letter of Credit
Cash or Cashier s Check
Personal/Company checks cannot be accepted. County approved forms for the various types of surety are available
upon request at the Grading Counter, Station 4, Room 122. Please note all signatures must be notarized.
Provide verification of contractor's coverage for Workman's Compensation insurance. If owner is doing work and
will not employ other workers, owner must sign exemption statement.
Owner or authorized agent and/or contractor must sign the permit at the time of issuance.
Authorized agent must have a notarized statement from the owner authorizing the agent to act on behalf of the owner.
The permittee and the entity providing the surety must be the same i.e., owner, developer or contractor.
Page 2 of 4 10/25/2010 4:05 PM
GB070010
Grading
Sheet Comments
General
1 B) Show site acreage and earthwork quantities on plans:
1.1 Cut _____ yds. (if applicable)
1.2 Fill ______ yds. (if applicable)
2 H) Show location of retaining walls on grading plan plus top of wall elevations,
adjacent finished surface elevations, top of footing elevations, provide a cross
section detail showing subdrain design, indicate drainage outlet for all retaining
walls. Retaining walls are not a part of the grading permit. Submit for separate
building permits; show connection of subdrain to storm drain. Note on plans.
3 N) Show all easements, (i.e. drainage, utilities, etc.).
4 Q) Approved erosion control measures are to be installed and functional during
the rainy season from October 15 to April 15. Justify design with hydrology and
hydraulic calculations. Submit three (3) copies of an erosion control plan and
a cost summary of erosion control facilities. If proposed grading will take place
after April 15, continue to show erosion control plans. Grading may extend into
the next rainy season.
5 W) Additional comments may be made after field verification that the plans and
soils report accurately reflects existing conditions.
6 Z) For sump pump please provide product brochure and website.. An electrical and
plumbing permit must be obtained from the Building Permits Division.
Drainage Instructions
7 W) Show retaining wall subdrain details with disposal points, flow line elevations
and pipe material.
8 X) Show typical section of driveway and pavement section. Include type of surfacing
material.
9 Y) Show typical section of hardscape. Include type of surfacing material.
Slopes
Geotechnical
10 A) Obtain approval of soils and geology report by County Geotechnical staff. Reports
Page 3 of 4 10/25/2010 4:05 PM = Indicates line item not Cleared.
GB070010
Grading
Sheet Comments
have been forwarded for their review.
Page 4 of 4 10/25/2010 4:05 PM = Indicates line item not Cleared.