Loading...
HomeMy WebLinkAboutH2023-0391 - MiscHZ023--03q ( SUBMITTAL AJ020BXJ2CH/AA(JXH20J2B) Page 1of4 e/ZI VI54A kjyK4- Samsung FJM Series, 2 Port Condensing Unit Job Name Purchaser Submitted to _ Unit Designation Location Engineer Reference 0 Approval 0 Construction Schedule # Model US Code JXH2OJ2B (Mode) Number i AJ020BXJ2CH/AA Capacity (min. / standard / max.) Cooling (Btu/h)i 5,500 / 18,000 / 18,000 Heating (Btu/h) I 3,500 / 22,000 / 26,400 SEER (Ducted / Mixed / Non -ducted)' ! 18.0 / 18.75 / 19.5 Performance EER (Ducted / Mixed / Non -ducted)' 11.1 / 11.9 / 12.7 HSPF (Ducted / Mixed / Non -ducted)' 9.5 / 9.75 / 10.0 SEER2 (Ducted / Mixed / Non-ducted)2 18.0 / 18.75 / 19.5 EER2 (Ducted / Mixed / Non-ducted)2 11.1 / 11.9 / 12.7 HSPF2 (Ducted / Mixed / Non-ducted)2 8.2 / 8.4 / 8.6 Voltage (o/V/Hz) 1 / 208-230 / 60 Power Nominal Current' iCooling (A) 6.8 !Heating (A) 8.3 Max. Breaker Amps 20 Minimum Circuit Ampacity (A) 16.5 EDimensions X H X D Inches 34 5/8 X 31 7/16 X 12 3/16 (Weight lbs. 116.8 Noise Level Cooling (Max.) dB (A) 4 Heating (Max.) IdB (A) 51 Operating Cooling 14 -- 114.8°F (-10 - 46.0'C) Temperatures Heating 5 -75°F (-15 - 24.0°C) High Side 1/4" X 2 Low Side (suction) 3/8" X 1 + 1/2" X 1 Pipe Maximum Individual Line Set Length 82 ft Connections Maximum Line Set Length (total) 164 ft Maximum Vertical Separation Outdoor to Indoor 49 ft Highest to Lowest Indoor 25 ft Included Pipe Adapter 1 - 1/2" X 3/8" Twin BLDC Rotary Inverter 11.2 Heat Exchanger Type Aluminum Fin -Copper Tube Type R410A Control Method I Electronic Expansion Valve Refrigerant Factory Charge 77.6 oz Charged for 98 ft Additional Refrigerant 0.11 oz/ft over 98 ft Wall Bracket Q CKN-250 Accessories Wind Baffle Front Q WBF-7M Back Q WBB-7M-B Certifications Safety ETL (UL 60335-2-40) Warranty 10 Years compressor, 10 year parts, 1 year limited labor (registration required) 'Performance data certified by AHRI to AHRI 210.240 (2017) with Addendum 1. 2Performance data certified by AHRI to AHRI 210.240 (2023). Effective January 1st, 2023. 'Rated current based on highest combination ratio of non -ducted Indoor units. This publication reflects both'the 1987 Appendix M metric (SEER) and the 2023 Appendix M1 metric (SEER2). Efficiency regfrements are published at 10 C.F.R. 430.32(c). Please refer to www.AHR]net.org for more information about updated energy metrics. ..Samsung HVAC maintains a policy of ongoing development, specifications are subject to change without notice. Refer to www.AHRIdirectory.org for current reference numbers. 2023 8amsurg.tiVAC 888 699 6067 -SHA,FJ M-JXH2OJ2B-2301 A General Information • Auto or manual addressing of indoor units • The outdoor unit shall supply power individually to the indoor units via 1413 AWG power wire • Auto -restart after power loss • Available maximum current setting option to reduce operating current • System energy consumption can be viewed using Samsung SmartThings mobile app (not revenue grade, for reference only) • Soft -start to reduce current demand during compressor start • Optional snow accumulation prevention setting to prevent snow drifting against idle outdoor units Construction • The outdoor unit shall be galvanized steel with a baked on powder coated finish for durability Heat Exchanger • The heat exchanger shall be mechanically bonded fin to copper tube Controls • Control signal shall be a DDC type signal • Interconnecting control wire between outdoor and indoor units shall be 16/2 AWG • The system shall integrate with Samsung Controls Solution without the use of an interface module Refrigerant System • The refrigerant shall be R410A • The compressor shall be hermetically sealed, inverter controlled, Twin Rotary BLDC • Refrigerant flow shall be controlled by 2 separate electronic expansion valves at outdoor unit rn ffP31 "-2q Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps (excluding ductless systems) must be matched with appropriate coil components to meet ENERGYSTAR criteria. Ask your contractor for details or visit www.energystar.gov www.SamsungHVAC.com Note: Qualification for ENERGYSTAR requires L use of non -ducted indoor units.(tblj5V9] ;' ``"k'N Intertek