HomeMy WebLinkAboutH2023-0391 - MiscHZ023--03q ( SUBMITTAL AJ020BXJ2CH/AA(JXH20J2B) Page 1of4
e/ZI VI54A kjyK4- Samsung FJM Series, 2 Port Condensing Unit
Job Name
Purchaser
Submitted to _
Unit Designation
Location
Engineer
Reference 0 Approval 0 Construction
Schedule #
Model
US Code JXH2OJ2B
(Mode) Number i AJ020BXJ2CH/AA
Capacity
(min. / standard / max.)
Cooling (Btu/h)i 5,500 / 18,000 / 18,000
Heating (Btu/h) I 3,500 / 22,000 / 26,400
SEER (Ducted / Mixed / Non -ducted)' ! 18.0 / 18.75 / 19.5
Performance
EER (Ducted / Mixed / Non -ducted)' 11.1 / 11.9 / 12.7
HSPF (Ducted / Mixed / Non -ducted)' 9.5 / 9.75 / 10.0
SEER2 (Ducted / Mixed / Non-ducted)2 18.0 / 18.75 / 19.5
EER2 (Ducted / Mixed / Non-ducted)2 11.1 / 11.9 / 12.7
HSPF2 (Ducted / Mixed / Non-ducted)2 8.2 / 8.4 / 8.6
Voltage
(o/V/Hz) 1 / 208-230 / 60
Power
Nominal Current'
iCooling (A) 6.8
!Heating (A) 8.3
Max. Breaker
Amps 20
Minimum Circuit Ampacity (A) 16.5
EDimensions
X H X D
Inches 34 5/8 X 31 7/16 X 12 3/16
(Weight
lbs. 116.8
Noise Level
Cooling (Max.)
dB (A) 4
Heating (Max.)
IdB (A) 51
Operating
Cooling 14 -- 114.8°F (-10 - 46.0'C)
Temperatures
Heating 5 -75°F (-15 - 24.0°C)
High Side 1/4" X 2
Low Side (suction) 3/8" X 1 + 1/2" X 1
Pipe
Maximum Individual Line Set Length 82 ft
Connections
Maximum Line Set Length (total) 164 ft
Maximum Vertical
Separation
Outdoor to Indoor 49 ft
Highest to Lowest Indoor 25 ft
Included Pipe Adapter 1 - 1/2" X 3/8"
Twin BLDC Rotary Inverter
11.2
Heat Exchanger Type Aluminum Fin -Copper Tube
Type R410A
Control Method I Electronic Expansion Valve
Refrigerant
Factory Charge 77.6 oz
Charged for 98 ft
Additional Refrigerant 0.11 oz/ft over 98 ft
Wall Bracket Q CKN-250
Accessories Wind Baffle Front Q WBF-7M
Back Q WBB-7M-B
Certifications Safety ETL (UL 60335-2-40)
Warranty 10 Years compressor, 10 year parts, 1 year limited labor (registration required)
'Performance data certified by AHRI to AHRI 210.240 (2017) with Addendum 1.
2Performance data certified by AHRI to AHRI 210.240 (2023). Effective January 1st, 2023.
'Rated current based on highest combination ratio of non -ducted Indoor units.
This publication reflects both'the 1987 Appendix M metric (SEER) and the 2023 Appendix
M1 metric (SEER2). Efficiency regfrements are published at 10 C.F.R. 430.32(c).
Please refer to www.AHR]net.org for more information about updated energy metrics.
..Samsung HVAC maintains a policy of ongoing development, specifications are subject to
change without notice. Refer to www.AHRIdirectory.org for current reference numbers.
2023 8amsurg.tiVAC 888 699 6067
-SHA,FJ M-JXH2OJ2B-2301 A
General Information
• Auto or manual addressing of indoor units
• The outdoor unit shall supply power individually to the indoor units
via 1413 AWG power wire
• Auto -restart after power loss
• Available maximum current setting option to reduce operating
current
• System energy consumption can be viewed using Samsung
SmartThings mobile app (not revenue grade, for reference only)
• Soft -start to reduce current demand during compressor start
• Optional snow accumulation prevention setting to prevent snow
drifting against idle outdoor units
Construction
• The outdoor unit shall be galvanized steel with a baked on powder
coated finish for durability
Heat Exchanger
• The heat exchanger shall be mechanically bonded fin to copper
tube
Controls
• Control signal shall be a DDC type signal
• Interconnecting control wire between outdoor and indoor units shall
be 16/2 AWG
• The system shall integrate with Samsung Controls Solution without
the use of an interface module
Refrigerant System
• The refrigerant shall be R410A
• The compressor shall be hermetically sealed, inverter controlled,
Twin Rotary BLDC
• Refrigerant flow shall be controlled by 2 separate electronic
expansion valves at outdoor unit
rn
ffP31 "-2q
Proper sizing and installation of equipment is critical to achieve
optimal performance. Split system air conditioners and heat pumps
(excluding ductless systems) must be matched with appropriate coil
components to meet ENERGYSTAR criteria. Ask your contractor for
details or visit www.energystar.gov