Loading...
HomeMy WebLinkAboutGB050053_Correction ListCounty of Orange Resources & Development Management Department Building Permits Division Main Office 300 N. Flower Street Santa Ana, CA 92702-4048 Grading Plan Check Corrections Corrections shall be made on the tracings and three(3) new sets of plans shall be submitted. If you make changes to the plan other than or in addition to what Plan Check has requested, yellow highlight the changes on one set of the re-submitted plans. Return the original check print with corrected plans. Payment of a new plan check deposit may be required for all plans on which no action is taken by the applicant for a period of 180 days. Applications for which no permit is issued within 180 days following the date of submittal shall expire by limitation, and shall be discarded. Project Number:GB050053 Submittal Date:Apr 26, 2005 CBC Edition: 2000 Plan Check Date: 5/12/2005 12:05 PM Description:precise for sfd and walls (Note that plans submiitted include impermissable 6 foot tall wall 0 feet Job Address 19 AVALON VISTA NEWPORT COAST, CA Owner Address Mike and Ana Meshkin 8 Talmont Irvine Coast CA92657 Current - 1st Plan Check Architect of Record ERIC TRABERT & ASSOCIATES 20351 Irvine, Suite #1 Santa Ana Heights CA92707 714-641-1505 Plan Checked By Javid Mohsenzadeh Javid.Mohsenzadeh@pdsd.ocgov.com 714-834-2662 Contact Address Elizabeth Innes 20351 Irvine Ave. Suite One Santa Ana Heights CA92707 714-641-1505 714-641-1091 FAX etrabert1@aol.com Page 1 of 3 GB050053 GENERAL INFORMATION Please provide 24-hour notice to your plan checker, prior to obtaining the grading Permit.Return the original check print with corrected plans. Payment of a new plan check deposit may be required for all plans on which the applicant takes no action for a period of 180 days. Applications for which no permit is issued within 180 days following date of submittal shall expire by limitation, and shall be discarded. SUBMITTALS, FEES, BOND, INSURANCE AND ISSUANCE Provide three (3) complete sets of corrected plans. Provide minimum 40-scale plan for precise grading. The maximum size shall be 36" x 42". All sheets shall be uniform size. Plans will not be rechecked at the counter. Allow one week for recheck. Plan check and inspection deposit amounts will be calculated by the plan checker based on earthwork quantities or drainage improvements, whichever is greater. The engineer shall provide this information. Surety is required in the amount of $ _________. Surety may be posted in one of the following forms: Bond Certificate of Deposit Letter of Credit Cash or Cashier s Check Personal/Company checks cannot be accepted. County approved forms for the various types of surety are available upon request at the Grading Counter, Station 4, Room 122. Please note all signatures must be notarized. Provide verification of contractor's coverage for Workman's Compensation insurance. If owner is doing work and will not employ other workers, owner must sign exemption statement. Owner or authorized agent and/or contractor must sign the permit at the time of issuance. Authorized agent must have a notarized statement from the owner authorizing the agent to act on behalf of the owner. The permittee and the entity providing the surety must be the same i.e., owner, developer or contractor. Page 2 of 3 5/12/2005 12:05 PM GB050053 Grading Plan Check Corrections Sheet Comments General 1 E) Submit an itemized summary of the unit and total cost of all drainage devices, grading, paving, and erosion control. 2 F) Show on Plans: 2.1 Grading Limits 2.2 Permit Limits 3 Q) Approved erosion control measures are to be installed and functional during the rainy season from October 15 to April 15. If proposed grading will take place after April 15, continue to show erosion control plans. Grading may extend into the next rainy season. 4 U) Show percent grade of all driveways. Drainage Instructions 5 X) Show typical section of driveway and pavement section. Include type of surfacing material. Geotechnical 6 A) Obtain approval of soils and geology report by County Geotechnical staff. Reports have been forwarded for their review. Page 3 of 3 5/12/2005 12:05 PM = Indicates line item not Cleared.