Loading...
HomeMy WebLinkAbout02_McGinnis Residence Coastal Development Permit_PA2023-0169 03/13/2018 CITY OF NEWPORT BEACH ZONING ADMINISTRATOR STAFF REPORT March 28, 2024 Agenda Item No. 2 SUBJECT: McGinnis Residence (PA2023-0169)  Coastal Development Permit SITE LOCATION: 4901 Seashore Drive APPLICANT/OWNER: Eric Trabert and Associates PLANNER: Jerry Arregui, Planning Technician 949-644-3249, jarregui@newportbeachca.gov LAND USE AND ZONING  General Plan: Single Unit Residential Detached (RS-D)  Zoning District: Single-Unit Residential (R-1)  Coastal Land Use Category: Single Unit Residential – 20.0 - 29.9 DU/AC (RS-D)  Coastal Zoning District: Single-Unit Residential (R-1) PROJECT SUMMARY A request for a coastal development permit to allow the demolition of an existing 2,473- square-foot nonconforming duplex to construct a new three-story, 2,403-square-foot, single- unit residence with a 182-square-foot junior accessory dwelling unit (JADU) and a 387- square-foot attached two-car garage. The design also includes appurtenances such as walls, hardscape, and landscaping. The project complied with all the development standards and no deviations from the Newport Beach Municipal Code (NBMC) are requested. RECOMMENDATION 1) Conduct a public hearing; 2) Find this project exempt from the California Environmental Quality Act (CEQA) pursuant to Section 15303 under Class 3 (New Construction or Conversion of Small Structures) of the CEQA Guidelines, California Code of Regulations, Title 14, Division 6, Chapter 3, because it has no potential to have a significant effect on the environment; and 3) Adopt Draft Zoning Administrator Resolution No. _ approving Coastal Development Permit No. PA2023-0169 (Attachment No. ZA 1). 1 McGinnis Residence (PA2023-0169) Zoning Administrator, March 28, 2024 Page 2 Tmplt: 04/03/18 DISCUSSION Land Use and Development Standards 1. The subject property is located in the R-1 Coastal Zoning District, which provides for single-unit residential development and is consistent with the City’s Coastal Land Use Plan, General Plan, and Zoning Code. A coastal development permit is required, and the property is not eligible for a waiver for de minimis development because the property is located in the Coastal Commission Appeal Area.  The property currently consists of one legal lot developed with a nonconforming duplex. The neighborhood is predominantly developed with two- and three-story single- and two-unit residences. The proposed three-story structure’s design, bulk, and scale of the development is consistent with the existing neighborhood pattern of development and expected future development (Figure 1). Figure 1: Oblique Image of Project Site  The proposed single-unit residence, JADU and accessory structures conform to all applicable development standards, including floor area limit, setbacks, height, and off-street parking as evidenced by the project plans and illustrated in Table 1 below. Subject Property 2 McGinnis Residence (PA2023-0169) Zoning Administrator, March 28, 2024 Page 3 Tmplt: 04/03/18 Table 1 – Development Standards Development Standard Standard Proposed Setbacks (min.) Front (West Ocean Front) 5 feet 5 feet Sides 3 feet 3 feet Second Frontage (Seashore) 0 feet 0 feet Allowable Floor Area (max.) 3,043 sq. ft. 2,973 sq. ft. JADU Floor Area (max) 500 sq. ft. 181 sq. ft. Allowable 3rd Floor Area (max.) 304 sq. ft. 301 sq. ft. Allowable 3rd Floor Coverage (max.) 760 sq. ft. 435 sq. ft. Open Space (min.) 228 sq. ft. 228 sq. ft. Parking (min.) 2-car garage 2-car garage Height (max.) 24-foot flat roof 29-foot sloped roof 23-foot, 10 inch flat roof 29-foot sloped roof Hazards The property fronts the Pacific Ocean and is more than 250 feet from the mean high tide line. The property is not protected by a bulkhead. A Coastal Hazards Report and Sea Level Rise Analysis was prepared by GeoSoils, Inc., dated August 23, 2023. The project site abuts the Pacific Ocean Beach and thus may be subject to coastal hazards such as flooding, runup, and erosion. The report determined that the proposed project is reasonably safe from shoreline erosion due to the lack of waves or wakes that can erode sand from the beach. The report also concludes that the project will be reasonably safe from future sea level rise assuming an increase up to 10.9 feet based on the North American Vertical Datum of 1988 (NAVD 88) (the likely range for sea level rise over the 75- year design life of the structure based on low-risk aversion estimates for sea level rise provided by the State of California, Sea Level Rise Guidance: 2018 Update). The finished floor elevation of the first floor of the proposed structure is 13.76 NAVD 88, which complies with the minimum 9.0-foot NAVD 88 elevation standard for new structures and exceeds the minimum requirements for sea level rise (10.9 feet NAVD 88). Based on the data provided, the study concludes that coastal hazards will not impact the property over the next 75 years and there is no anticipated need for a shore protection device over the life of the proposed development. As conditioned pursuant to NBMC Section 21.30.030(C)(3)(i) - (Natural Landform and Shoreline Protection), the property owner will be required to enter into an agreement with the City waiving any potential right to protection to address situations in the future in which the development is threatened with damage or destruction by coastal hazards (e.g., waves, erosion, and sea level rise). The property owner will also be required to acknowledge any hazards present at the site and unconditionally waive any claim to damage or liability against the decision authority, consistent with NBMC Section 21.30.015(D)(3)(c) – (General Site Planning and Development 3 McGinnis Residence (PA2023-0169) Zoning Administrator, March 28, 2024 Page 4 Tmplt: 04/03/18 Standards). Both requirements are included as conditions of approval that will need to be satisfied prior to the issuance of building permits for construction.  The property is located in an area known for the potential of seismic activity and liquefaction. All projects are required to comply with the California Building Code (CBC) and Building Division standards and policies. Geotechnical investigations specifically addressing liquefaction are required to be reviewed and approved prior to the issuance of a building permit. Permit issuance is also contingent on the inclusion of design mitigation identified in the investigations. Construction plans are reviewed for compliance with approved investigations and the CBC prior to building permit issuance. Public Access and Views  The project site is located on the Balboa Peninsula between the nearest public road and the sea. Implementation Plan Section 21.30A.040 (Determination of Public Access/Recreation Impacts) requires that the provision of public access bear a reasonable relationship between the requirement and the project’s impact and be proportional to the impact. In this case, the project replaces an existing duplex with a new single-unit residence and JADU. Therefore, the project does not involve a change in land use, density or intensity that will result in increased demand on public access and recreation opportunities.  The project is located adjacent to a public beach with an average width of more than 300 feet. The project is designed and sited to not block or impede existing public access opportunities, and all development occurs within the confines of private property. Existing coastal access conditions will not be affected by the project. The project site is located between 49th and 50th Street, which are identified by the Coastal Land Use Plan as public beach access locations. The project does not interfere with the existing nearby access to the beach. Lateral access to the bay is available at the street ends of 49th and 50th Street. Vertical access is not available near the project site.  The project site is not located adjacent to a coastal view road or public accessway, as identified in the Coastal Land Use Plan. The project is located approximately 1,000 feet from Sunset Ridge Park, which is identified as a Public View Point by the Coastal Land Use Plan. Additionally, the project may be located within the viewshed of other distant public viewing areas. Site evaluation revealed that the proposed three-story design is consistent with the existing neighborhood pattern of development and will not affect the existing views afforded from the surrounding streets. The project will replace an existing duplex with a new single-unit residence and JADU that complies with all applicable Local Coastal Program (LCP) development standards and maintains a building envelope consistent with the existing neighborhood pattern of development. Therefore, the project does not have the potential to degrade the visual quality of the Coastal Zone or result in significant adverse impacts to public views. 4 McGinnis Residence (PA2023-0169) Zoning Administrator, March 28, 2024 Page 5 Tmplt: 04/03/18  An existing 5-foot-deep encroachment area on the beach frontage is authorized by an existing encroachment permit. Any future expansion of the patio encroachment area requires a separate review and permit from the California Coastal Commission and a new encroachment permit from the Public Works Department. Water Quality  The project is located approximately 275 feet from the mean high tide line. NBMC section 21.35.030 (Construction Pollution Prevention Plan), a Construction Pollution Prevention Plan (CPPP) is required to implement temporary Best Management Practices (BMPs) during construction to minimize erosion and sedimentation and to minimize pollution runoff and coastal waters derived by construction chemicals and materials. The CPPP has been provided and reviewed by the City’s Engineer Geologist. Construction plans and activities will be required to adhere to the approved CPPP. ENVIRONMENTAL REVIEW This project is exempt from the California Environmental Quality Act (CEQA) pursuant to Section 15303 under Class 3 (New Construction or Conversion of Small Structures) of the CEQA Guidelines, California Code of Regulations, Title 14, Division 6, Chapter 3, because it has no potential to have a significant effect on the environment. Class 3 exempts the demolition of up to three single-unit residences and additions of up to 10,000 square feet to existing structures. The project is to demolish an existing duplex and construct a new single-unit residence with an attached JADU located in the R-1 Coastal Zoning District within a development neighborhood. Therefore, the Class 3 exemption is applicable. There are no known exceptions listed in CEQA Guidelines Section 15300.2 that would invalidate the use of this exemption. The project location does not impact an environmental resource of hazardous or critical concern, does not result in cumulative impacts, does not have a significant effect on the environment due to unusual circumstances, does not damage scenic resources within a state scenic highway, is not a hazardous waste site, and is not identified as a historical resource. PUBLIC NOTICE Notice of this public hearing was published in the Daily Pilot, mailed to all owners and residential occupants of property within 300 feet of the boundaries of the site (excluding intervening rights-of-way and waterways), including the applicant, and posted on the subject property at least 10 days before the scheduled hearing, consistent with the provisions of the Municipal Code. Additionally, the item appeared on the agenda for this meeting, which was posted at City Hall and on the City website. 5 McGinnis Residence (PA2023-0169) Zoning Administrator, March 28, 2024 Page 6 Tmplt: 04/03/18 APPEAL PERIOD: This action shall become final and effective 14 days following the date the Resolution is adopted unless within such time an appeal or call for review is filed with the Community Development Director in accordance with the provisions of Title 21 (Local Coastal Implementation Plan) of the Newport Beach Municipal Code. Final action taken by the City may be appealed to the Coastal Commission in compliance with Section 21.64.035 of the City’s certified LCP and Title 14 California Code of Regulations, Sections 13111 through 13120, and Section 30603 of the Coastal Act. For additional information on filing an appeal, contact the Planning Division at 949-644-3200. Prepared by: DL/ja Attachments: ZA 1 Draft Resolution ZA 2 Vicinity Map ZA 3 Project Plans 6 03/13/2018 Attachment No. ZA 1 Draft Resolution 7 RESOLUTION NO. ZA2024-### A RESOLUTION OF THE ZONING ADMINISTRATOR OF THE CITY OF NEWPORT BEACH, APPROVING A COASTAL DEVELOPMENT PERMIT FOR THE DEMOLITION OF AN EXISTING NONCONFORMING DUPLEX AND THE CONSTRUCTION OF A NEW THREE-STORY, 2,403-SQUARE- FOOT, SINGLE-UNIT RESIDENCE WITH A 182-SQUARE-FOOT JUNIOR ACCESSORY DWELLING UNIT (JADU) AND A 387- SQUARE-FOOT ATTACHED TWO-CAR GARAGE LOCATED AT 4901 SEASHORE DRIVE (PA2023-0169) THE ZONING ADMINISTRATOR OF THE CITY OF NEWPORT BEACH HEREBY FINDS AS FOLLOWS: SECTION 1. STATEMENT OF FACTS. 1. An application was filed by Eric Trabert and Associates (Applicant) on behalf of Lisa McGinnis (Owner), with respect to property located at 4109 Seashore Drive, and legally described as Lot 1 of Block 49 of the Ocean Front Tract (Property), requesting approval of a coastal development permit (CDP). 2. The Applicant proposes to demolish an existing 2,473-square-foot nonconforming duplex and to construct a new three-story, 2,403-square-foot, single-unit residence with a 182- square-foot junior accessory dwelling unit (JADU) and a 387-square-foot attached two-car garage. The design also includes appurtenances such as walls, hardscape, and landscaping (Project). 3. The Property is located within the Single-Unit Residential (R-1) Zoning District and the Single Unit Residential Detached (RS-D) General Plan Land Use Element category. The R-1 Zoning District permits single-unit residences. The existing duplex is considered nonconforming due to density as it was constructed in 1982 when the property was previously zoned as Two-Unit Residential (R-2). 4. The Property is located within the coastal zone. The property is within the Single-Unit Residential (R-1) Coastal Zoning District and within the Single Unit Residential Detached (RSD-D 20.0 – 29.9 DU/AC) Coastal Land Use Plan category. 5. A public hearing was held on March 28, 2024, online via Zoom. A notice of time, place, and purpose of the hearing was given in accordance with the Newport Beach Municipal Code (NBMC). Evidence, both written and oral, was presented to, and considered by, the Zoning Administrator at this hearing. SECTION 2. CALIFORNIA ENVIRONMENTAL QUALITY ACT DETERMINATION. 1. This Project is categorically exempt pursuant to Title 14 of the California Code of Regulations Section 15303, Division 6, Chapter 3, Guidelines for Implementation of the California Environmental Quality Act (CEQA) under Class 3 (New Construction or 8 Zoning Administrator Resolution No. ZA2024-### Page 2 of 9 01-03-17 Conversion of Small Structures), because it has no potential to have a significant effect on the environment. 2. Class 3 exempts the demolition of up to 3 single-unit residences and additions of up to 10,000 square feet to existing structures. The Project is to demolish an existing duplex and construct a new single-unit residence with a JADU in the R-1 Coastal Zoning District within a developed neighborhood. Therefore, the Class 3 exemption is applicable. 3. The exceptions to this categorical exemption under Section 15300.2 are not applicable. The project location does not impact an environmental resource of hazardous or critical concern, does not result in cumulative impacts, does not have a significant effect on the environment due to unusual circumstances, does not damage scenic resources within a state scenic highway, is not a hazardous waste site, and is not identified as a historical resource. SECTION 3. REQUIRED FINDINGS. In accordance with Section 21.52.015(F) (Findings and Decision) of the NBMC, the following findings and facts in support of such findings are set forth: Finding: A. Conforms to all applicable sections of the certified Local Coastal Program. Facts in Support of Finding: 1. The Project complies with applicable residential development standards including, but not limited to, floor area limitation, setbacks, height, and parking. a. The maximum floor area limitation is 3,043 square feet and the proposed floor area is 2,973 square feet. b. The proposed development complies with the required setbacks, which are 5 feet from West Ocean Front, 0 feet from Seashore Drive, and 3 feet along each side property line. The second and third story balconies facing West Ocean Front encroach up to 36 inches into the required setback as allowed by NBMC Section 21.30.110(D)(5). c. The highest guardrail/parapet measured 24 feet from the established grade and the highest ridge measures 29 feet from the established grade. The Project complies with all height requirements. d. The Project provides a two-car garage, complying with the minimum garage requirement for a single-unit residence. The proposed JADU does not require additional parking. 9 Zoning Administrator Resolution No. ZA2024-### Page 3 of 9 01-03-17 e. The Project includes one JADU, where one JADU is allowed as part of new construction within a proposed single-unit residence. The maximum floor area for a JADU is 500 square feet and the proposed JADU is 161 square feet. f. The Project proposed a minimum top slab elevation of 13.76 feet based on the North American Vertical Datum of 1988 (NAVD 88) which complies with the minimum 9.0-foot NAVD 88 top of slab elevation requirement for interior living areas of new structures. 2. The Project proposes to demolish the existing nonconforming duplex on-site to construct a single-unit residence and JADU. As a result, the Project complies with the Housing Crisis Act of 2019 and Senate Bill 8 (Skinner) because it does not result in the loss of residential density. The State Department of Housing and Community Development (HCD) has verified with the City in an email dated March 23, 2022, that an ADU is considered a housing unit under Government Code Section 66300 provisions to replace existing units. The Owner has certified that the units are not "protected" units under Section 66330 Subdivision (d)(2). The Project is consistent with the General Plan, Local Coastal Program, and Zoning designations that allow the single-unit and accessory dwelling unit land uses. Under Coastal Land Use Plan Table 2.1.1-1, the Single-Unit Residential Detached (RSD-D) category is intended to provide for single-unit residential development. Implementation Program (IP) Table 21.18-1 shows “Single-Unit Dwellings – Detached” and “Junior Accessory Dwelling Units” as allowed uses in the R-1 Coastal Zoning District. Therefore, the Project of a single-unit residence and junior accessory dwelling unit to replace the existing duplex is consistent with the R-1 zoning and land use designations and does not result in a loss of residential density. 3. The neighborhood is predominantly developed with two- and three-story single- and two- unit residences. The proposed three-story residence’s design, bulk, and scale of the development is consistent with the existing neighborhood pattern of development and expected future development. 4. A Coastal Hazards Report and Sea Level Rise Analysis was prepared by GeoSoils, Inc., dated August 23, 2023. The Property abuts the Pacific Ocean beach and thus may be subject to coastal hazards such as flooding, runup, and erosion. The report concludes that the Project is reasonably safe from shoreline erosion due to the lack of waves or wakes that can erode sand from the beach. The report also concludes that the Project will be reasonably safe from future sea level rise assuming an increase up to 10.9 feet based on the North American Vertical Datum of 1988 (NAVD 88) (the likely range for sea level rise over the 75-year design life of the structure based on low-risk aversion estimates for sea level rise provided by the State of California, Sea Level Rise Guidance: 2018 Update). The finished floor elevation of the first floor of the proposed structure is 13.76 NAVD 88, which complies with the minimum 9.0-foot NAVD 88 elevation standard for new structures and exceeds the minimum requirements for sea level rise (10.9 feet NAVD 88). Based on the data provided, the study concludes that coastal hazards will not impact the Property over the next 75 years and there is no anticipated need for a shore protection device over the life of the proposed development. 10 Zoning Administrator Resolution No. ZA2024-### Page 4 of 9 01-03-17 5. Pursuant to NBMC Section 21.30.030(C)(3)(i) (Natural Landform and Shoreline Protection) of the NBMC, the Owner will be required to enter into an agreement with the City waiving any potential right to protection to address situations in the future in which the development is threatened with damage or destruction by coastal hazards (e.g., waves, erosion, and sea level rise). The Owner will also be required to acknowledge any hazards present at the site and unconditionally waive any claim to damage or liability against the decision authority, consistent with NBMC Section 21.30.015(D)(3)(c) (General Site Planning and Development Standards). These requirements are included as Condition of Approval No. 7 and 8 that will need to be satisfied prior to final building inspection, and prior to the issuance of building permits, respectively. 6. The Property is located in an area known for the potential of seismic activity and liquefaction. All projects are required to comply with the California Building Code (CBC) and Building Division standards and policies. Geotechnical investigations specifically addressing liquefaction are required to be reviewed and approved prior to the issuance of building permits. Permit issuance is also contingent on the inclusion of design mitigation identified in the investigations. Construction plans are reviewed for compliance with approved investigations and the CBC prior to building permit issuance. 7. The Property is not located adjacent to a coastal view road or public accessway, as identified in the Coastal Land Use Plan. The Project is located approximately 1,000 feet southwest of Sunset Ridge Park, which is identified as a Public View Point by the Coastal Land Use Plan. Additionally, the Project may be located within the viewshed of other distant public viewing areas. Site evaluation revealed that the proposed three-story design is consistent with the existing neighborhood pattern of development and will not affect the existing views afforded from the surrounding streets. The Project will replace an existing duplex with a new single-unit residence and JADU that complies with all applicable Local Coastal Program (LCP) development standards and maintains a building envelope consistent with the existing neighborhood pattern of development. Therefore, the Project does not have the potential to degrade the visual quality of the Coastal Zone or result in significant adverse impacts to public views. Finding: B. Conforms with the public access and public recreation policies of Chapter 3 of the Coastal Act if the project is located between the nearest public road and the sea or shoreline of any body of water located within the coastal zone. Facts in Support of Finding: 1. The Property is located between the nearest public road and the sea. Implementation Plan Section 21.30A.040 (Determination of Public Access/Recreation Impacts) requires that the provision of public access bear a reasonable relationship between the requirement and the Project’s impact and be proportional to the impact. In this case, the Project replaces an existing duplex with a new single-unit residence and JADU. Therefore, the Project does not involve a change in land use, density or intensity that will result in increased demand on public access and recreation opportunities. Furthermore, the Project is designed and sited so as not to block or impede existing public access opportunities. 11 Zoning Administrator Resolution No. ZA2024-### Page 5 of 9 01-03-17 2. Fact in Support of Finding A.2 is hereby incorporated by reference. 3. The Property is located adjacent to a public beach and is approximately 275 feet from the mean high tide line. The Project is designed and sited to not block or impede existing public access opportunities, and all development occurs within the confines of private property. Existing coastal access conditions will not be affected by the Project. The Property is located between 49th and 50th Street, which are identified by the Coastal Land Use Plan as public beach access locations. The Project does not interfere with the existing nearby access to the beach. Lateral access to the bay is available at the street ends of 49th and 50th Street. Vertical access is not available near the project site. SECTION 4. DECISION. NOW, THEREFORE, BE IT RESOLVED: 1. The Zoning Administrator of the City of Newport Beach hereby finds this Project is categorically exempt from the California Environmental Quality Act pursuant to Section 15303 under Class 3 (Conversion or Construction of Small Structures) of the CEQA Guidelines, California Code of Regulations, Title 14, Division 6, Chapter 3, because it has no potential to have a significant effect on the environment and that the exceptions to the Class 3 Exemption do not apply. 2. The Zoning Administrator of the City of Newport Beach hereby approves Coastal Development Permit No. PA2023-0169, subject to the conditions set forth in Exhibit “A,” which is attached hereto and incorporated by reference. 3. This action shall become final and effective 14 days following the date this Resolution was adopted unless within such time an appeal or call for review is filed with the Community Development Director in accordance with the provisions of Title 21 Local Coastal Implementation Plan, of the Newport Beach Municipal Code (NBMC). Final action taken by the City may be appealed to the Coastal Commission in compliance with Section 21.64.035 (Appeal to the Coastal Commission) of the City’s certified LCP and Title 14 California Code of Regulations, Sections 13111 through 13120, and Section 30603 of the Coastal Act. PASSED, APPROVED, AND ADOPTED THIS 28TH DAY OF MARCH, 2024. Benjamin M. Zdeba, AICP, Zoning Administrator 12 Zoning Administrator Resolution No. ZA2024-### Page 6 of 9 01-03-17 EXHIBIT “A” CONDITIONS OF APPROVAL Planning Division 1. The development shall be in substantial conformance with the approved site plan, floor plans, and building elevations stamped and dated with the date of this approval (except as modified by applicable conditions of approval). 2. Revisions to the approved plans may require an amendment to this Coastal Development Permit or the processing of a new Coastal Development Permit. 3. The Project is subject to all applicable City ordinances, policies, and standards unless specifically waived or modified by the conditions of approval. 4. The Applicant shall comply with all federal, state, and local laws. Material violation of any of those laws in connection with the use may be cause for revocation of this Coastal Development Permit. 5. This Coastal Development Permit may be modified or revoked by the Zoning Administrator if determined that the proposed uses or conditions under which it is being operated or maintained is detrimental to the public health, welfare or materially injurious to property or improvements in the vicinity or if the Property is operated or maintained so as to constitute a public nuisance. 6. Coastal Development Permit No. PA2023-0169 shall expire and become void unless exercised within 24 months from the date of approval as specified in Section 21.54.060 (Time Limits and Extensions) of the NBMC, unless an extension is otherwise granted. 7. Prior to final building permit inspection, an agreement in a form approved by the City Attorney between the property owner and the City shall be executed and recorded waiving rights to the construction of future shoreline protection devices to address the threat of damage or destruction from waves, erosion, storm conditions, landslides, seismic activity, bluff retreat, sea level rise, or other natural hazards that may affect the property, or development of the property, today or in the future. The agreement shall be binding against the property owners and successors and assigns. 8. Prior to the issuance of a building permit, the Owner shall submit a notarized signed letter acknowledging all hazards present at the site, assuming the risk of injury or damage from such hazards, unconditionally waiving any claims of damage against the City from such hazards, and to indemnify and hold harmless City, its City Council, its boards and commissions, officials, officers, employees, and agents from and against any and all claims, demands, obligations, damages, actions, causes of action, suits, losses, judgments, fines, penalties, liabilities, costs and expenses (including without limitation, attorney’s fees, disbursements and court costs) of every kind and nature whatsoever which may arise from or in any manner relate (directly or indirectly) to City’s approval of development. 13 Zoning Administrator Resolution No. ZA2024-### Page 7 of 9 01-03-17 9. No demolition or construction materials, equipment debris, or waste, shall be placed or stored in a location that would enter sensitive habitat, receiving waters, or a storm drain or result in impacts to environmentally sensitive habitat areas, streams, the beach, wetlands or their buffers. 10. This Coastal Development Permit does not authorize any development seaward of the private property. 11. This approval does not authorize any new or existing improvements (including landscaping) on State tidelands, public beaches, or the public right-of-way. 12. Best Management Practices (BMPs) and Good Housekeeping Practices (GHPs) shall be implemented before and throughout the duration of construction activity as designated in the Construction Erosion Control Plan. 13. The discharge of any hazardous materials into storm sewer systems or receiving waters shall be prohibited. Machinery and equipment shall be maintained and washed in confined areas specifically designed to control runoff. A designated fueling and vehicle maintenance area with appropriate berms and protection to prevent spillage shall be provided as far away from storm drain systems or receiving waters as possible. 14. Debris from demolition shall be removed from work areas each day and removed from the Property within 24 hours of the completion of the Project. Stock-piles and construction materials shall be covered, enclosed on all sites, not stored in contact with the soil, and located as far away as possible from drain inlets and any waterway. 15. Trash and debris shall be disposed in proper trash and recycling receptacles at the end of each construction day. Solid waste, including excess concrete, shall be disposed in adequate disposal facilities at a legal disposal site or recycled at a recycling facility. 16. Prior to the issuance of building permits, the Applicant shall submit a final landscape and irrigation plan. These plans shall incorporate drought tolerant plantings, non- invasive plant species and water efficient irrigation design. The plans shall be approved by the Planning Division. 17. All landscape materials and irrigation systems shall be maintained in accordance with the approved landscape plan. All landscaped areas shall be maintained in a healthy and growing condition and shall receive regular pruning, fertilizing, mowing, and trimming. All landscaped areas shall be kept free of weeds and debris. All irrigation systems shall be kept operable, including adjustments, replacements, repairs, and cleaning as part of regular maintenance. 18. The Applicant is responsible for compliance with the Migratory Bird Treaty Act (MBTA). In compliance with the MBTA, grading, brush removal, building demolition, tree trimming, and similar construction activities shall occur between August 16 and January 31, outside of the peak nesting period. If such activities must occur inside the peak nesting season from February 1 to August 15, compliance with the following is required to prevent the taking of Native Birds pursuant to MBTA: 14 Zoning Administrator Resolution No. ZA2024-### Page 8 of 9 01-03-17 A. The construction area shall be inspected for active nests. If birds are observed flying from a nest or sitting on a nest, it can be assumed that the nest is active. Construction activity within 300 feet of an active nest shall be delayed until the nest is no longer active. Continue to observe the nest until the chicks have left the nest and activity is no longer observed. When the nest is no longer active, construction activity can continue in the nest area. B. It is a violation of state and federal law to kill or harm a native bird. To ensure compliance, consider hiring a biologist to assist with the survey for nesting birds, and to determine when it is safe to commence construction activities. If an active nest is found, 1 or 2 short follow-up surveys will be necessary to check on the nest and determine when the nest is no longer active. 19. Prior to issuance of building permits, a waterproofing curb or similar design feature shall be constructed around the proposed residence as an adaptive flood protection device up to a maximum of 10.9 feet (NAVD88). Flood shields (sandbags and other methods) can be deployed across the openings to protect and prevent flooding to the structure. 20. Construction activities shall comply with Section 10.28.040 (Construction Activity – Noise Regulations) of the Newport Beach Municipal Code, which restricts hours of noise-generating construction activities that produce noise to between the hours of 7:00 a.m. and 6:30 p.m., Monday through Friday. Noise-generating construction activities are not allowed on Saturdays, Sundays, or Holidays. 21. Prior to the issuance of building permits, the Applicant shall pay any unpaid administrative costs associated with the processing of this application to the Planning Division. 22. Should the Property be sold or otherwise come under different ownership, any future owners or assignees shall be notified of the conditions of this approval by either the current business owner, property owner, or the leasing agent. 23. To the fullest extent permitted by law, Applicant shall indemnify, defend and hold harmless City, its City Council, its boards and commissions, officials, officers, employees, and agents from and against any and all claims, demands, obligations, damages, actions, causes of action, suits, losses, judgments, fines, penalties, liabilities, costs and expenses (including without limitation, attorney’s fees, disbursements and court costs) of every kind and nature whatsoever which may arise from or in any manner relate (directly or indirectly) to City’s approval of McGinnis Residence including, but not limited to, Coastal Development Permit No. PA2023-0169. This indemnification shall include, but not be limited to, damages awarded against the City, if any, costs of suit, attorneys’ fees, and other expenses incurred in connection with such claim, action, causes of action, suit or proceeding whether incurred by Applicant, City, and/or the parties initiating or bringing such proceeding. The Applicant shall indemnify the City for all of City’s costs, attorneys’ fees, and damages which City incurs in enforcing the indemnification provisions set forth in this condition. The Applicant shall pay to the City upon demand any amount owed to the City pursuant to the indemnification requirements prescribed in this condition. 15 Zoning Administrator Resolution No. ZA2024-### Page 9 of 9 01-03-17 Building Division 24. Prior to the issuance of building permits, the Applicant shall submit a final drainage and grading plan. The plan shall be subject to the review and approval by the Building Division. 25. Prior to issuance of the building permits, a copy of the Resolution, including conditions of approval Exhibit “A” shall be incorporated into the Building Division and field sets of plans. 26. Prior to the issuance of building permits, the Applicant shall submit a final construction erosion control plan. The plan shall be subject to the review and approval by the Building Division. 27. Prior to issuance of building permits, the Applicant shall submit a soils report which include recommendations for construction on liquefiable soils. Additionally, the building foundation shall comply with the minimum requirements of the City of Newport Beach Building Code Policy CBC 1803.5.11-12. 16 03/13/2018 Attachment No. ZA 2 Vicinity Map 17 03/13/2018 VICINITY MAP Coastal Development Permit PA2023-0169 4901 Seashore Drive Subject Property 18 Tmplt: 04/03/18 Attachment No. ZA 3 Project Plans 19 01 30 20 21 22 23 24 25 26 27 28 LOT APN T J LEGENDDESCRIPTION MEASURED ELEVATIONS RECORD BERING & DISTANCE DECKWALLBUILDINGPROPERTY LINEASPHALTCAC CONCRETE (123.45)( ) ACC 0'8'16' SCALE 1" = 8' N 3 4 ° 2 5 ' 5 5 " E 6 7 . 8 6 ' N 55°34'05" W 30.00' N 3 4 ° 2 5 ' 5 5 " E 6 8 . 9 3 ' N 53°31'20" W 30.02' SEASHORE DRIVE 49 T H S T R E E T OCEAN FRONT LOT 1 3 STORYBUILDING 2 STORYBUILDING GARAGE FOUND SPIKE & WASHER FOUND LEAD AND TAG L.S. 8682 (42.35)RIDGE (36 . 5 5 ) RID G E BUILDING BUILDING BUILDING BUILDING EDIS O N B OX (12 . 8 1 F S ) (13. 8 6 F S ) (13 . 8 7 F S ) (14 . 0 8 F S ) (13 . 8 6 F S ) (14.2 7 F F ) (13.3 3 F S ) (13.5 6 G F ) (13. 3 5 F S ) (13 . 8 9 F S ) (13 . 3 5 F S ) (13 . 4 9 F S ) GM (13 . 2 9 F S ) (13 . 5 5 F S ) (13 . 8 4 F S ) (13 . 8 5 F S ) (14. 0 5 F S ) (17.0 2 T W ) (17 . 0 5 T W ) (13 . 9 2 F S ) (13. 7 6 F S ) (13 . 6 8 G F ) WM (12 . 7 5 ) (17.11T W ) (12.5 8 T C ) WM(12.95 ) (14 . 2 2 F S ) (16.15TW) (17.0 4 T W ) (17.0 4 T W ) (15 . 9 2 T W ) (15 . 9 3 T W ) (15 . 9 1 T W ) (15.1 0 T W ) (15.0 8 T W ) (15.1 0 T W ) (14 . 5 9 T W ) (13.2 9 F S ) (13. 3 7 F S ) (12. 7 3 N G ) (13.1 6 N G ) (13 . 5 5 N G ) (12. 9 5 N G ) (13.83FS)(13.84FS) (13 . 8 4 F S ) (15.97TW) (14 . 0 9 T W ) (13.2 6 F S ) SIGN (14.6 0 T W ) (13. 2 9 F S ) (14. 1 2 T W ) (13 . 3 0 F S ) (13 . 4 2 F S ) (19.2 2 T W ) (13.3 1 F S ) (15.9 3 T W ) (13 . 3 4 F S ) (19. 4 3 T W ) (13. 2 4 F S ) NO PA R K S I G N (13. 2 7 F S ) (13.1 9 F S ) (13.2 5 T C ) (13 . 1 0 T C X ) (12.6 8 F S ) (12 . 7 1 F S ) (13 . 2 1 T C X ) (12. 7 5 F S ) (12 . 7 7 F S ) (12 . 6 3 F S ) (12.3 5 F L ) (13 . 1 4 T C ) (12.6 4 F S ) (13.0 8 T C ) (12. 5 9 F S ) (12.9 9 T C ) (12. 5 5 F S ) (12 . 3 4 F S ) (12.82 T C X ) (12 . 2 9 F S ) (12.41 F S ) (12. 2 0 F S ) (12.19 F S ) (12. 4 6 F S ) (12.3 8 F L ) (12.2 7 F S ) (13. 1 8 T C ) (13.09 T C X ) FH (12.4 5 ) 0" T C (12.5 4 F S ) (12.8 3 T C ) (12 . 4 8 F S ) (12 . 5 6 F S ) (12. 7 1 F S ) (12 . 6 3 F L ) (12.51FL) (12 . 3 8 F L ) (15.32 T W ) P P P LINE OF DECK LINE OF DECKLINE OF DECK LINE OF DECK 16. 2 5.3 2.6 2.9 2.9 6.6 (15. 9 3 T W ) PROPERTYLINE PROPERTYLINE PROPERTYLINE PRO P E R T Y LIN E CENTERLINE CENTERLINE S.F.N.S.F.N. (13 . 0 F S ) S.F.N. S.F.N. AC AC AC AC AC AC AC AC ACAC AC AC SAND SAND SAND SAND SAND SAND SAND SAND 15.0 5.015.05.0 3.2 4.8 P GUTTER GUTTER GUTTER 20. 0 20. 0 DESCRIPTDESCRIBEALUMINUSET IN THFT. CONCLOCATEDINTERSECCOAST HICENTERLSOUTHERMONUME(14.3FS) (12. 8 N G ) (13.1 N G ) (13.4N G ) (13.4N G ) (13. 1 N G ) PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE 13.76 FF 5 8 12.5 5 FL RT 13.50 TG12.75 INV 1 4N 5% 13.59 HP/F L 13.6 7 FS 13.67 FG 13.67 FS 13.6 7 FS 13.67 FS 13.6 7 FS 13.5 FS13.6 7 FS 12.7 7 FS 12.98 FS 21 (14 FFFFFFFFFFFF 55 (1312.5 F 13.75 TG 13.00 INV 1 [ 12.85 GFF ] [ 13.28 GFF ] 2% 13.20 TC12.66 INV 31 13.75 TG 12.87 INV 2 16 ' ( L I M I T S O F R E D C U R B ) 13.00 TC 12.58 FS 6" CURB 12.58 FS 12.33 FS 0" CF 12.30 FS 0" CF 12.33 FS 0" CF 8.00' 3.85% 5% 1.5 3 % 22 (1 13.19 FS 23 42 S 41 WW (12 SD SD SD 2% DECORATIVE DRIVEWAY AND WALKWAY REQUIRE AN ENCROACHMENT PERMIT AND ENCROACHMENT AGREEMENT. 25 30' 19' 19.2 2 TW (16.1 5 ) TW 3'8' 3.2 0 ' 1.2 4 % 0.7 7 % 1.72 % (17.0 2 ) TW 7 7FF 8 4 7 CONCRETE TILE DRIVEWAY 6.7%4.2 8 ' (12.4 8 ) FL (12.3 4 ) FL 10% 24 " 3.00'3.16' 5.0 6 ' 6.0 2 ' 4.9 5 ' 4.2 9 ' 12.77 FS 20 . 5 9 ' 19.22 TW 1.39% XX.XX TG XX.XX INVX XX.XX FG X 36"PROPOSED TREE NOTE: NOT ALL SYMBOLS USED HARDSCAPE DRIVEWAY BUILDING STORM DRAIN SUMP PUMP DISCHARGE ASSEMBLY GRADING LEGEND, PROPOSED RETAINING WALL PROPOSED SIDE PROPERTY WALL PROPOSED SITE SCREEN WALL PROPOSED ROOF DOWN SPOUT PROPOSED PLANTER DRAIN INLET PROPOSED SQ. GRATE DRAIN INLET PROPOSED PERFORATED SUBDRAIN PROPOSED 12" MAIN CATCH BASIN PROPOSED EARTHEN DRAINAGE SWALE PL PROPERTY LINE PROPOSED 4" STORM DRAIN LINE FG: FS: DS: INV: TOS: TG: FL: NG: TC: TW: TF: FF: GFF: FINISHED GRADE FINISHED SURFACE DOWNSPOUT INVERT ELEVATION TOP OF SLAB TOP OF GRATE (DRAIN INLET) FLOW LINE NATURAL GRADE ELEV TOP OF CURB TOP OF WALL TOP OF FOOTING FINISHED FLOOR GARAGE FINISHED FLOOR SYMBOLS AND ABBREVIATIONS PROPOSED 6" STORM DRAIN LINE PERF SUBDRAIN 4" 6" PROPERTY LINE PROPOSED CHANNEL DRAIN PROPOSED CONCRETE DRAINAGE SWALE HP:HIGH POINT DG LAWN/TURF BOX LOCATION PLANTER AREA/ NATURAL GROUND FLOW ARROW DRAIN INLET CALLOUT CONSTRUCTION NOTE PROPOSED SPOT ELEVATION (XX.XX) FG EXISTING SPOT ELEVATION GRADE SLOPE PERCENTAGE XX % WOOD DECK PROPOSED 4" PERFORATED PIPE POOL/ SPA PR E L I M I N A R Y GR A D I N G & D R A I N A G E P L A N 1 2 CDP-01 "ALL WORK RELATED TO WATER IN THE PUBLIC RIGHT-OF-WAY SHALL BE PERFORMED BY A C-34 LICENSED PIPELINE CONTRACTOR OR AN A LICENSED GENERAL ENGINEERING CONTRACTOR." "ALL WORK RELATED TO WASTEWATER IN THE PUBLIC RIGHT-OF-WAY SHALL BE PERFORMED BY A C-42 LICENSED SANITATION SEWER CONTRACTOR OR AN A LICENSED GENERAL ENGINEERING CONTRACTOR." "A CAL-OSHA PERMIT IS REQUIRED FOR EXCAVATIONS DEEPER THAN 5' AND FOR SHORING AND UNDERPINNING.” "PRIOR TO PERFORMING ANY WORK IN THE CITY RIGHT-OF-WAY AN ENCROACHMENT PERMIT MUST BE OBTAINED FROM THE PUBLIC WORKS DEPARTMENT." "SURVEYOR OR ENGINEER SHALL PERMANENTLY MONUMENT PROPERTY CORNERS OR OFFSETS BEFORE STARTING GRADING." "A PUBLIC WORKS DEPARTMENT ENCROACHMENT PERMIT INSPECTION IS REQUIRED BEFORE THE BUILDING DEPARTMENT PERMIT FINAL CAN BE ISSUED. AT THE TIME OF PUBLIC WORKS DEPARTMENT INSPECTION, IF ANY OF THE EXISTING PUBLIC IMPROVEMENTS SURROUNDING THE SITE IS DAMAGED, NEW CONCRETE SIDEWALK, CURB AND GUTTER, AND ALLEY/STREET PAVEMENT WILL BE REQUIRED. ADDITIONALLY, IF EXISTING UTILITIES INFRASTRUCTURE ARE DEEMED SUBSTANDARD, A NEW 1-INCH WATER SERVICE, WATER METER BOX, SEWER LATERAL AND/OR CLEANOUT WITH BOX AND LID WILL BE REQUIRED. 100% OF THE COST SHALL BE BORNE BY THE PROPERTY OWNER (MUNICIPAL CODES 14.24.020 AND 14.08.030). SAID DETERMINATION AND THE EXTENT OF THE RECONSTRUCTION WORK SHALL BE MADE AT THE DISCRETION OF THE PUBLIC WORKS INSPECTOR. CONTRACTOR IS RESPONSIBLE TO MAINTAIN THE PUBLIC RIGHT OF WAY AT ALL TIMES DURING THE CONSTRUCTION PROJECT. A STOP WORK NOTICE MAY BE ISSUED FOR ANY DAMAGE OR UNMAINTAINED PORTION OF THE PUBLIC RIGHT OF WAY." "AN ENCROACHMENT AGREEMENT IS REQUIRED FOR ALL NON-STANDARD IMPROVEMENTS WITHIN THE PUBLIC RIGHT OF WAY. ALL NON-STANDARD IMPROVEMENTS SHALL COMPLY WITH CITY COUNCIL POLICY L-6." PUBLIC WORKS GENERAL NOTES: 20 GRAPHIC SCALE: 1"= 10' 10 300 SCALE: 1"=10' PRELIMINARY GRADING/DRAINAGE PLAN d'zn engineering PLANS PREPARED BY: THESE PLANS WERE PREPAREDUNDER THE SUPERVISION OF: IN M ISS ED AL ON LA-A ENG A E P R D INOISTERE ROF .L No. C54067 E REG LI A IALFORNIICSEXP. ETATOF V 12/31/25 C EER 166 MATISSE CIRCLEALISO VIEJO, CA 92656 TEL: (949) 305-8920 CLIENT/OWNER: BEACHFRONT INVESTMENTS 96 Corporate Park, Irvine, CA 92606Contact: Lisa McGinnis714-493-5718 LMcGinnis@bomelconstruction.com SHEET TITLE PROJECT_ADDRESS 4901 Seashore Drive, Newport Beach, CA 92663 BENCHMARK- - APN: 424-452-06 DATE: 16-JAN-2024ENGINEER: R. DEMA-ALA CHECKER: R. DEMA-ALA PROJECT_No:2237 REVISIONS STATUS: SUBMITTAL 2 SHEET OF SHEETS CONSTRUCTION NOTES: INSTALL 18x18 SHALLOW CATCH BASIN-PER FLO-GARD, LOPRO, FG-M1818 OR APPROVED EQUAL. SEE DETAIL 1 ON G-03. (TIE INTO EXISTING CURB OUTLET). 1 5 4 2 INSTALL 6" SQUARE GRATE & ADAPTER, NDS 640 OR EQUAL. SEE DETAIL 2 ON G-03. INSTALL 4" MAINLINE DRAIN PIPE, SDR 35 PVC OR EQUAL. CONNECT TO EXISTING CURB OUTLET PER CITY STD31 PROVIDE DRAINAGE SWALE IN CONCRETE FLATWORK PER DETAIL 9 ON SHEET G-03. EXISTING PROPERTY LINE WALLS TO REMAIN. (PROTECT-IN-PLACE) 21 NEW CURB ACCESS RAMP PER CITY STANDARD 18122 NEW SIDEWALK PER CITY STANDARD 18023 INSTALL NEW SEWER CLEANOUT ON EXISTING SEWER LATERAL PER CITY STANDARD 40641 CONNECT NEW WATER LINE TO EXISTING WATER METER AND WATER SERVICE42 7 ROOF DOWNSPOUT DISCHARGE ABOVE FLATWORK TO SITE DRAINAGE PIPING AS PER SOILS REPORT RECOMMENDATIONS. SEE DETAIL 8 ON G-03. 8 ROOF DOWNSPOUT DISCHARGE DIRECT-CONNECT TO SITE DRAINAGE PIPING AS PER SOILS REPORT RECOMMENDATIONS. SEE DETAIL 7 ON G-03. REMOVE AND CONSTRUCT NEW 6' HIGH PROPERTY LINE WALL ENTIRELY WITHIN PROPERTY LIMITS 25 29 ANCE N 3 4 ° 2 5 ' 5 5 " E 6 7 . 8 6 ' N 55°34'05" W 30.00' N 3 4 ° 2 5 ' 5 5 " E 6 8 . 9 3 ' N 53°31'20" W 30.02' SEASHORE DRIVE 49 T H S T R E E T OCEAN FRONT LOT 1 3 STORYBUILDING 2 STORYBUILDING GARAGE FOUND SPIKE & WASHER FOUND LEAD AND TAG L.S. 8682 (42.35)RIDGE (36. 5 5 ) RID G E BUILDING BUILDING EDIS O N B OX (12.8 1 F S ) (13 . 8 6 F S ) (13 . 8 7 F S ) (14.0 8 F S ) (13 . 8 6 F S ) (14. 2 7 F F ) (13.33 F S ) (13.5 6 G F ) (13 . 3 5 F S ) (13 . 8 9 F S ) (13 . 3 5 F S ) (13 . 4 9 F S ) GM (13 . 2 9 F S ) (13 . 5 5 F S ) (13 . 8 4 F S ) (13 . 8 5 F S ) (14. 0 5 F S ) (17.0 2 T W ) (17 . 0 5 T W ) (13 . 9 2 F S ) (13 . 7 6 F S ) (13.6 8 G F ) WM(12.75 ) (17.11T W ) (12 . 5 8 T C ) WM (12. 9 5 ) (14 . 2 2 F S ) (16.15TW) (17. 0 4 T W ) (17. 0 4 T W ) (15 . 9 2 T W ) (15. 9 3 T W ) (15 . 9 1 T W ) (15. 1 0 T W ) (15. 0 8 T W ) (15. 1 0 T W ) (14.59T W ) (13.2 9 F S ) (13 . 3 7 F S ) (12.7 3 N G ) (13.1 6 N G ) (13 . 5 5 N G ) (12.95 N G ) (13.83FS)(13.84FS) (13 . 8 4 F S ) (15.97TW) (14 . 0 9 T W ) (13.2 6 F S ) SIG N (14.60 T W ) (13. 2 9 F S ) (14. 1 2 T W ) (13 . 3 0 F S ) (13 . 4 2 F S ) (19.2 2 T W ) (13. 3 1 F S ) (15. 9 3 T W ) (13 . 3 4 F S ) (19. 4 3 T W ) (13 . 2 4 F S ) NO PA R K S I G N (13 . 2 7 F S ) (13.1 9 F S ) (13.25 T C ) (13 . 1 0 T C X ) (12.6 8 F S ) (12 . 7 1 F S ) (13.2 1 T C X ) (12 . 7 5 F S ) (12 . 7 7 F S ) (12 . 6 3 F S ) (12 . 3 5 F L ) (13 . 1 4 T C ) (12.6 4 F S ) (13.0 8 T C ) (12. 5 9 F S ) (12. 9 9 T C ) (12. 5 5 F S ) (12.3 4 F S ) (12. 8 2 T C X ) (12 . 2 9 F S ) (12 . 4 1 F S ) (12. 2 0 F S ) (12. 1 9 F S ) (12. 4 6 F S ) (12 . 3 8 F L ) (12. 2 7 F S ) (13.18 T C ) (13.09 T C X ) FH (12 . 4 5 ) 0" TC (12.5 4 F S ) (12.8 3 T C ) (12.4 8 F S ) (12 . 5 6 F S ) (12 . 7 1 F S ) (12.63F L ) (12.5 1 F L ) (12 . 3 8 F L ) (15.32 T W ) P P P LINE OF DECK LINE OF DECK 16. 2 5.3 2.6 2.9 2.9 6.6 (15. 9 3 T W ) PROPERTYLINE PROPERTYLINE PROPERTYLINE PRO P E R T Y LIN E CENTERLINE CENTERLINE S.F.N.S.F.N. (13 . 0 F S ) S.F.N. S.F.N. AC AC AC AC AC AC AC AC ACAC AC AC SAND SAND SAND SAND SAND SAND SAND SAND 15.0 5.015.05.0 3.2 4.8 P GUTTER GUTTER GUTTER 20. 0 (14.3FS) (12.8 N G ) (13.1N G ) (13.4N G ) (13. 4 N G ) (13. 1 N G ) SECTION ASECTION A SE C T I O N B SE C T I O N 13.20 TC12.66 INV 31 13.75 TG 12.87 INV 2 16 ' ( L I M I T S O F R E D C U R B ) 8.00' S 30' 19'3'8' 3.2 0 ' 4.2 8 ' 3.00'3.16' 5.0 6 ' 6.0 2 ' 4.9 5 ' 4.2 9 ' 20 . 5 9 ' N 53°31'20" W 30.02' (13.8 6 F S ) (1 3 . 8 7 F S ) (14.0 8 F S ) (1 3 . 8 6 F S ) (1 4 . 2 7 F F ) (1 3 . 8 4 F S ) (13. 8 5 F S ) (14 . 0 5 F S ) (1 4 . 2 2 F S ) (16.15T W ) W)W)(13 83FS) (13 84FS) (15.97TW) (1 4 . 1 2 T W (19 . 2 2 T W ) (13. 3 1 F S ) (15 . 9 3 T W ) (13 . 3 4 F S ) (15 . 9 3 T W) PROPERTYLINE PROPERTYLINE PR O P E R T Y LIN E S.F.N. S.F.N.4. 8 P 14 16 12 18 20 13.76 FF 14 16 12 18 20 13.76 FF GARAGE PR E L I M I N A R Y C O N S T R U C T I O N PO L L U T I O N P R E V E N T I O N P L A N 2 2 CDP-02 20 GRAPHIC SCALE: 1"= 10' 10 300 SCALE: 1"=10' CONSTRUCTION POLLUTION PREVENTION PLAN d'zn engineering PLANS PREPARED BY: 27 F e b 2 0 2 4 2 2 3 7 - G R D . d w g THESE PLANS WERE PREPARED UNDER THE SUPERVISION OF: IN M ISS ED AL ON LA-A ENG A E P R DINOISTERE ROF .L No. C54067 E REG LI A IALFORNIICS EXP. E TATOF V 12/31/25 C EER 166 MATISSE CIRCLE ALISO VIEJO, CA 92656 TEL: (949) 305-8920 CLIENT/OWNER: BEACHFRONT INVESTMENTS 96 Corporate Park, Irvine, CA 92606 Contact: Lisa McGinnis 714-493-5718LMcGinnis@bomelconstruction.com SHEET TITLE PROJECT_ADDRESS 4901 Seashore Drive, Newport Beach, CA 92663 BENCHMARK- - APN: 424-452-06 DATE: 16-JAN-2024 ENGINEER: R. DEMA-ALA CHECKER: R. DEMA-ALA PROJECT_No:2237 REVISIONS STATUS: SUBMITTAL 2 SHEET OF SHEETS PL 3'- 0 " (19.4 3 ) TW 14.2 5 TW (13. 1 6 ) NG (14.0 8 ) FS (13. 8 6 ) FS(14.2 7 ) FS (13.5 6 ) FS (13.0 ) FS (12. 3 4 ) FS (12. 3 8 ) FL (12. 4 8 ) FS (13.2 7 ) FS(13. 8 9 ) FS (13. 5 5 ) FS (13.9 2 ) FS EXISTING GRADE(17.0 2 ) TW (12.8 2 ) TC X PROPERTY LINE PL PL PL LIMIT OF OVEREXCAVATION LIMIT OF OVEREXCAVATION EXISTING WALL AND FOOTING TO REMAIN PROTECT-IN PLACE (E) GROUND SURFACE (E) GROUND SURFACE 11 11 EROSION CONTROL NOTES: EROSION & SEDIMENT CONTROL CONSTRUCTION NOTES: EC1 CONSTRUCT GRAVEL BAG EROSION CONTROL ALONG PROPERTY LINES EXCEPT DRIVEWAY APPROACHES. THE SAND BAGS SHOULD BE 24" WIDE AND 10" HIGH MINIMUM PER DETAIL HEREON AND IN ACCORDANCE WITH BMP FACTS SHEETS # SE-8. EC2 CONSTRUCT SANITARY WASTE MANAGEMENT AREA IN ACCORDANCE WITH BMP FACTS SHEETS # WM-9. EC3 CONSTRUCT MATERIALS STORAGE AREA IN ACCORDANCE WITH BMP FACTS SHEETS # WM-1. EC4 EXISTING WALL TO REMAIN. PROTECT IN PLACE. ALL BMP'S SHALL BE IN ACCORDANCE WITH MODEL BMP'S FROM THE CALIFORNIA STORMWATER BMP HANDBOOK FOR CONSTRUCTION AT WWW.CABMPHANDBOOKS.COM 1. IN CASE OF EMERGENCY, CALL BEACHFRONT INVESTMENTS AT PHONE # 714-493-5718. 2. A STAND-BY CREW FOR EMERGENCY WORK SHALL BE AVAILABLE AT ALL TIMES DURING THE RAINY SEASON (OCTOBER 1 TO APRIL 15). NECESSARY MATERIALS SHALL BE AVAILABLE ON-SITE AND STOCKPILED AT CONVENIENT LOCATIONS TO FACILITATE RAPID CONSTRUCTION OF EMERGENCY DEVICES WHEN RAIN IS IMMINENT. 3. EROSION CONTROL DEVICES SHOWN ON THIS PLAN MAY BE REMOVED WHEN APPROVED BY THE BUILDING OFFICIAL IF THE GRADING OPERATION HAS PROGRESSED TO THE POINT WHERE THEY ARE NO LONGER REQUIRED. 4. GRADED AREAS ADJACENT TO FILL SLOPES LOCATED AT THE SITE PERIMETER MUST DRAIN AWAY FOM THE TOP OF THE SLOPE AT THE CONCLUSION OF EACH WORKING DAY. ALL LOOSE SOILS AND DEBRIS THAT MAY CREATE A POTENTIAL HAZARD TO OFF-SITE PROPERTY SHALL BE STABILIZED OR REMOVED FROM THE SITE ON A DAILY BASIS. 5. RUNOFF ALL SILT AND DEBRIS SHALL BE REMOVED FROM ALL DEVICES WITHIN 24 HOURS AFTER EACH RAINSTORM AND BE DISPOSED OF PROPERLY. 6. A GUARD SHALL BE POSTED ON THE SITE WHENEVER THE DEPTH OF WATER IN ANY DEVICE EXCEEDS 2 FEET. THE DEVICE SHALL BE DRAINED OR PUMPED DRY WITHIN 24 HOURS AFTER EACH RAINSTORM. PUMPING AND DRAINING OF ALL BASINS AND DRAINAGE DEVICES MUST COMPLY WITH THE APPROPRIATE BMP FOR DEWATERING OPERATIONS. 7. THE PLACEMENT OF ADDITIONAL DEVICES TO REDUCE EROSION DAMAGE AND CONTAIN POLLUTANTS WITHIN THE SITE IS LEFT TO THE DISCRETION OF THE FIELD ENGINEER. ADDITIONAL DEVICES AS NEEDED SHALL BE INSTALLED TO RETAIN SEDIMENTS AND OTHER POLLUTANTS ON SITE. 8. DESILTING BASINS MAY NOT BE REMOVED OR MADE INOPERABLE BETWEEN NOVEMBER 1 AND APRIL 15 OF THE FOLLOWING YEAR WITHOUT THE APPROVAL OF THE BUILDING OFFICIAL. 9. STORM WATER POLLUTION AND EROSION CONTROL DEVICES ARE NOT TO BE MODIFIED, AS NEEDED, AS THE PROJECT PROGRESSES. THE DESIGN AND PLACEMENT OF THESE DEVICES IS THE RESPONSIBILITY OF THE FIELD ENGINEER. PLANS REPRESENTING CHANGES MUST BE SUBMITTED FOR APPROVAL IF REQUESTED BY THE BUILDING OFFICIAL. 10. EVERY EFFORT SHALL BE MADE TO ELIMINATE THE DISCHARGE OF NON-STORM WATER FROM THE PROJECT SITE AT ALL TIMES. 11. ERODED SEDIMENTS AND OTHER POLLUTANTS MUST BE RETAINED ON-SITE AND MAY NOT BE TRANSPORTED FROM THE SITE VIA SHEET FLOW, SWALES, AREA DRAINS, NATURAL DRAINAGE COURSES, OR WIND. 12. STOCKPILES OF EARTH AND OTHER CONSTRUCTION RELATED MATERIALS MUST BE PROTECTED FROM BEING TRANSPORTED FROM THE SITE BY THE FORCES OF WIND OR WATER. 13. FUELS, OILS, SOLVENTS AND OTHER TOXIC MATERIALS MUST BE STORED IN ACCORDANCE WITH THEIR LISTING AND ARE NOT CONTAMINATE THE SOILS AND SURFACE WATERS. ALL APPROVED STORAGE CONTAINERS ARE TO BE PROTECTED FROM THE WEATHER. SPILLS MUST BE CLEANED UP IMMEDIATELY AND DISPOSED OF IN A PROPER MANNER. SPILLS MAY NOT BE WASHED INTO THE DRAINAGE SYSTEM. 14. EXCESS OR WASTE CONCRETE MAY NOT BE WASHED INTO THE PUBLIC WAY OR ANY OTHER DRAINAGE SYSTEM. PROVISIONS SHALL BE MADE TO RETAIN CONCRETE WASTES ON-SITE UNTIL THEY CAN BE DISPOSED OF AS SOLID WASTE. 15. DEVELOPERS/CONTRACTORS ARE RESPONSIBLE TO INSPECT ALL EROSION CONTROL DEVICES AND BMP'S ARE INSTALLED AND FUNCTIONING PROPERLY IF THERE IS A 40% CHANCE OF QUARTER INCH OR MORE OF PREDICTED PRECIPITATION, AND AFTER ACTUAL PRECIPITATION. A CONSTRUCTION SITE INSPECTION CHECKLIST AND INSPECTION LOG SHALL BE MAINTAINED AT THE PROJECT SITE AT ALL TIMES AND AVAILABLE FOR REVIEW BY THE BUILDING OFFICIAL (COPIES OF THE SELF-INSPECTION CHECKLIST AND INSPECTION LOGS ARE AVAILABLE UPON REQUEST). 16. TRASH AND CONSTRUCTION RELATED SOLID WASTES MUST BE DEPOSITED INTO A COVERED RECEPTACLE TO PREVENT CONTAMINATION OF RAINWATER AND DISPERSAL BY WIND. 17. SEDIMENTS AND OTHER MATERIALS MAY NOT BE TRACKED FROM THE SITE BY VEHICLE TRAFFIC. THE CONSTRUCTION ENTRANCE ROADWAYS MUST BE STABILIZED SO AS TO INHIBIT SEDIMENTS FROM BEING DEPOSITED INTO THE PUBLIC WAY. ACCIDENTAL DEPOSITIONS MUST BE SWEPT UP IMMEDIATELY AND MAY NOT BE WASHED DOWN BY RAIN OR OTHER MEANS. 18. ANY SLOPES WITH DISTURBED SOILS OR DENUDED OF VEGETATION MUST BE STABILIZED SO AS TO INHIBIT EROSION BY WIND AND WATER. 19. HOME OWNER TO ROUTINELY CLEAN ALL CATCH BASINS AND DRAIN LINES OF DEBRIS. 20. ADDITIONAL BMP'S WILL BE IMPLEMENTED AS DEEMED NECESSARY BY CITY INSPECTORS. EC2TW) EC3 222 EC1 " ( EC4 ( (MINIMUM BMP REQUIREMENTS FOR CONSTRUCTION ACTIVITIES FOR ALL DEVELOPMENT CONSTRUCTION PROJECTS) SCALE: 1/4"=1'-0" SECTION A-A CONTROLLED COMPACTED FILL (E) SOILS OVEREXCAVATION PER SOILS REPORT SCALE: 1/4"=1'-0" SECTION B-B 3'- 0 " CONTROLLED COMPACTED FILL (E) SOILS OVEREXCAVATION PER SOILS REPORT 13.75 FS NOTE: SLAB ON GRADE SHALL BE MORE THAN 6" ABOVE EXISTING GRADE FS 30 31 (42.35)RIDGE (13 . 8 6 F S ) (13 . 8 7 F S ) (14.08FS) (1 3 . 8 6 F S ) (14.2 7 F F ) (13.3 3 F S ) (13 . 5 6 G F ) (13 . 3 5 F S ) (1 3 . 8 9 F S ) (13 . 3 5 F S ) (1 3 . 4 9 F S ) GM (1 3 . 2 9 F S ) (1 3 . 5 5 F S ) (13 . 8 4 F S ) (13 . 8 5 F S ) 4.0 5 F S ) (17 . 0 2 T W ) (17 . 0 5 T W ) (1 3.9 2 F S ) (13 . 7 6 F S ) 5) (17.11 T W ) (12 . 5 8 T C ) WM (1 2 . 9 5 ) (1 4 . 2 2 F S ) (16.15T W ) (17.0 4 T W ) (1 5 . 9 2 T W ) (15 . 9 3 T W ) (1 5 . 9 1 T W ) (15.1 0 T W ) (15 . 0 8 T W ) (15 ( (12.7 3 N G ) (13 . 1 6 N G ) (13 . 5 5 N G ) (12 . 9 5 N G ) (13.83FS)(13.84FS) (1 3 . 8 4 F S ) (15.97TW) (1 SIG (14.60T (13.2 9 (14.12TW) (19.22TW) (13.31FS) (15 . 9 3 T W ) (13.34FS) (19 . 4 3 T W ) (1 3 . 2 4 F S ) NO P A R K S I G N (13.2 7 F S ) (13 . 1 9 F S ) (13.25T (1 3 . 1 4 T C ) (12 . 6 4 FS ) (1 3 . 0 8 T C ) (12 . 5 9 FS (12 . 9 9 T C ) (12.5 5 FS (12.3 4 F S ) (12.8 2 T C X ) (12 . 2 9F (12 . 2 7 F S )(12.4 8 F S ) (12.56 F S ) (12.51F L ) (12.38FL) (15.32 T W ) (15.93TW) (13.0 F S ) AC AC AC 15.05.0 (14.3TW ) 49 T H S T R E E T OCEAN FRONT (SAND) AD J A C E N T 2 S T O R Y B L D G (L O T 2 ) SEASHORE DRIVE PROPOSED BUILDING (LOT 1)                                +13.70 FS +13.70 FS FS 13.67+FS 13.67+                                                                                                                                                           GENERAL NOTES 1. CONTRACTOR SHALL VERIFY WITH OWNER'S REPRESENTATIVE THAT PLANS ARE CURRENT ANDAPPROVED.2. WORK SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF THE CITY OF NEWPORT BEACHAND THE COUNTY OF ORANGE3. THE CONTRACTOR SHALL OBTAIN ALL NECESSARY AND/OR REQUIRED PERMITS AND PAY ALLRELATED FEES AND/OR TAXES REQUIRED TO INSTALL THE WORK ON THESE PLANS.4. THE CONTRACTOR SHALL BE APPROPRIATELY LICENSED AS REQUIRED BY THE STATE IN WHICHTHE WORK TAKES PLACE.5. A SEPARATE PLUMBING PERMIT AND INSPECTION WILL BE REQUIRED FROM THE BUILDING INSPECTION DEPARTMENT FOR THE INSTALLATION OF IRRIGATION SYSTEMS SHOWN ON THISDRAWING.6. THE CONTRACTOR SHALL NOTIFY THE OWNER'S REPRESENTATIVE PRIOR TO BEGINNING THE WORK AND SHALL BE RESPONSIBLE FOR COORDINATING WITH THE OWNER, LANDSCAPEARCHITECT, GOVERNING AGENCIES AND OTHER TRADES.7. CONTRACTOR SHALL NOTIFY LANDSCAPE ARCHITECT IMMEDIATELY OF ANY ERRORS,OMISSIONS OR DISCREPANCIES IN EXISTING CONDITIONS OR WITHIN THE PLANS PRIOR TOBEGINNING THE WORK.8. UNIT PRICES FOR ALL IMPROVEMENTS SHALL BE ESTABLISHED AS A PART OF THE CONTRACTWITH THE PROJECT OWNER AND PRIOR TO BEGINNING WORK, TO ACCOMMODATE ADDITIONSAND/OR DELETIONS OF MATERIAL AND/OR LABOR.9. DETERMINATION OF "EQUAL" SUBSTITUTIONS SHALL BE MADE ONLY BY THE LANDSCAPEARCHITECT.10. LANDSCAPE ARCHITECT SHALL BE NOTIFIED NO LESS THAN 48 HOURS IN ADVANCE OF ANY SITE OBSERVATIONS OR MEETINGS.11. SITE OBSERVATIONS AND MEETINGS SHALL INCLUDE:A. PRE-CONSTRUCTION CONFERENCE B. SELECTION AND TAGGING OF SPECIMEN TREES AT NURSERIESC. LANDSCAPE GRADING PRIOR TO PLANTINGD. LAYOUT AND INSTALLATION OF HARDSCAPE AND LANDSCAPE STRUCTURES IN RELATION TO DESIGN INTENTE. PLANT MATERIAL QUALITY AND INSTALLATION AT THE PROJECT SITEF. OBSERVATION TO ESTABLISH 90-DAY MAINTENANCE PERIOD (PRE-MAINTENANCE)G. FINAL OBSERVATION AT THE END OF THE 90-DAY MAINTENANCE PERIOD (FINAL)14. SITE OBSERVATIONS BY THE LANDSCAPE ARCHITECT DURING ANY PHASE OF THIS PROJECTDOES NOT RELIEVE THE CONTRACTOR OF HIS PRIMARY RESPONSIBILITY TO PERFORM ALLWORK IN ACCORDANCE WITH THE PLANS, SPECIFICATIONS AND GOVERNING CODES.15. CONTRACTOR SHALL BE BACKCHARGED FOR LANDSCAPE ARCHITECT'S TIME WHEN OBSERVATIONS ARE CALLED FOR AND IT IS FOUND THAT THE WORK IS NOT SIGNIFICANTLYREADY UPON OBSERVATION OR THE APPOINTMENT IS NOT KEPT. TIME WILL BE CHARGED ON ANHOURLY BASIS, PLUS TRANSPORTATION, FOOD AND LODGING COSTS, IF ANY, AT THE THEN EXISTING HOURLY RATE FOR THE PERSONNEL PROVIDING THE OBSERVATIONS.16. THIS FIRM DOES NOT PRACTICE OR CONSULT IN THE FIELD OF SAFETY ENGINEERING. THIS FIRMDOES NOT DIRECT THE CONTRACTOR'S OPERATIONS, AND IS NOT RESPONSIBLE FOR THE SAFETY OF PERSONNEL OTHER THAN OUR OWN ON THE SITE; THE SAFETY OF OTHERS IS THERESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR SHOULD NOTIFY THE OWNER IF HECONSIDERS ANY OF THE RECOMMENDED ACTIONS PRESENTED HEREIN TO BE UNSAFE. NOTE: "LANDSCAPE" SHALL REFER TO ALL IMPROVEMENTS WITHIN THIS SET OF DOCUMENTS THATHAVE BEEN DESIGNED BY THIS OFFICE.          PROJECT TEAM     PROJECT CALCULATIONS      PERMIT NOTE    PROJECT INFORMATION   SYMBOL DESCRIPTION PROPERTY LINE SETBACK EX. UTILITIES TO REMAIN EX. CONCRETE TO REMAIN EX. CURB/GUTTER TO REMAIN EX.OFF-SITE PLANTER WALLS STUCCO/BLOCK WALL - REFER TO ARCHITECTURE PLANS PROPOSED LOW WALL - 36" HEIGHT STUCCO WALL WITH CONCRETECAP PROPOSED FENCE/GATE - 6' HIGH, VERTICAL WOOD SLAT FENCE W/HARDWARE SELECTED BY OWNER/CONTRACTOR. FENCE TO BESTAINED. PROPOSED WALL - 36" HEIGHT TOTAL, 6" STUCCO WALL W/CONCRETE CAP W/ 30" GLASS ON TOP PROPOSED TILE, OUTDOOR RATED TILE INSTALLED OF CONCRETEBASE - TILE SELECTION BY OWNER AND INSTALL PER MANFACTURERRECOMENDATIONS. TILE TO HAVE SUGGEST R11 OR GREATER SLIPCOEFFICIENT. TILE IN CARPORT AND DRIVEWAY SHOULD BEREINFORCED TO HANDLE VEHICULAR TRAFFIC PROPOSED FENCE/GATE - 36" WIDE, 36" HEIGHT TOTAL, 6" STUCCOWALL W/ CONCRETE CAP W/ 30" GLASS GATE ON TOP. HARDWARESELECTED BY OWNER/CONTRACTOR. PLANTING AREA - REFER TO PLANTING PLAN FOR PLANT MATERIAL               I HAVE COMPLIED WITH THE CRITERIA OF THE WATER EFFICIENT LANDSCAPE ORDINANCE AND APPLIED SUCH CRITERIA FOR THE EFFICIENT USE OF WATER IN THE LANDSCAPE DESIGN PLAN. 1-23-24 _____________________________________________ ________________________BLAKE TOMILLOSO-RHINEHART, LANDSCAPE ARCHITECT DATE CA LICENSE #6255 08-31-24____________________________________________ ______________ REGISTRATION EXP. DATE DECLARATION OF WATER EFFICIENT LANDSCAPE ORDINANCE  32 GM 5) WM (1 2 . 9 5 ) SIG NO P A R K S I G N AC AC AC 15.05.0 49 T H S T R E E T OCEAN FRONT (SAND) AD J A C E N T 2 S T O R Y B L D G (L O T 2 ) SEASHORE DRIVE PROPOSED BUILDING (LOT 1) +13.70 FS +13.70 FS FS 13.67+FS 13.67+                                                                                                                                                       PLANTING NOTES 1. THE LANDSCAPE CONTRACTOR SHALL INSTALL PERMEABLE WEED FABRIC IN ALL PLANTING AREAS.2. THE LANDSCAPE CONTRACTOR SHALL INSTALL A 3" DEEP LAYER OF 1-2" DECORATIVE PEBBLES INALL PLANTING AREAS.3. THE CONTRACTOR SHALL AMEND PROJECT SOILS PER THE SPECIFICATIONS.4. THE LANDSCAPE CONTRACTOR SHALL PROVIDE A 60 DAY MAINTENANCE PERIOD AND GUARANTEE TREE FOR A 1 YEAR PERIOD. ALL PLANT MATERIAL SHALL BE REPLACED BY THE LANDSCAPECONTRACTOR DURING THIS PERIOD IF DEAD OR DYING.5. LANDSCAPE INSPECTIONS ARE REQUIRED. NOTIFY THE CITY OF NEWPORT BEACH BUILDING DEPARTMENT 48 HOURS IN ADVANCE OF ANY WORK BEING DONE. CALL 714.536.5241.6. THE INSTALLATION OF REQUIRED LANDSCAPE AND IRRIGATION SYSTEMS SHALL BE COMPLETEDPRIOR TO FINAL INSPECTION.          PROJECT TEAM     PROJECT CALCULATIONS      PERMIT NOTE    PROJECT INFORMATION     SHRUBS CODE BOTANICAL / COMMON NAME SIZE WUCOLS SPACING QTY AV AGAVE VILMORINIANA 5 GAL L 18" o.c. 3OCTOPUS AGAVE FG FESTUCA GLAUCA 1 GAL L 18" o.c. 10BLUE FESCUE FP FICUS PUMILA 5 GAL M 48" o.c. 11CREEPING FIG PS PITTOSPORUM TENUIFOLIUM 'SILVER SHEEN' 15 GAL M 48" o.c. 4SILVER SHEEN TAWHIWHI PM PODOCARPUS MACROPHYLLUS 'MAKI' 15 GAL M 36" o.c. 2MAKI YEW PODOCARPUS  33 GM 5) WM (1 2 . 9 5 ) SIG NO P A R K S I G N AC AC AC 15.05.0 49 T H S T R E E T OCEAN FRONT (SAND) AD J A C E N T 2 S T O R Y B L D G (L O T 2 ) SEASHORE DRIVE PROPOSED BUILDING (LOT 1) BF MV FS A SS      M +13.70 FS +13.70 FS FS 13.67+FS 13.67+                                                                                                                                                         SYMBOL MANUFACTURER/MODEL/DESCRIPTION RAIN BIRD XCZ-100-PRB-COM WIDE FLOW DRIP CONTROL KIT 1" BALL VALVE WITH 1" PESB VALVE AND 1" PRESSURE REGULATING 40PSI QUICK-CHECK BASKET FILTER. 0.3GPM TO 20GPM. PIPE TRANSITION POINT PIPE TRANSITION POINT FROM PVC LATERAL TO DRIP TUBING OR DRIP HEADER PER MANUFACTURER`S RECOMMENDATIONS. HUNTER PLD-BV (NOT SHOWN) MANUAL FLUSH/SHUT OFF VALVE, BARBED INSERT. TYPICALLY INSTALLED IN ROUND BOX, WITH ADEQUATE BLANK TUBING TO EXTEND VALVE OUT OF VALVE BOX. INSTALL AT THE EXHAUST HEADERS AND LOW POINTS WITHIN A DRIP CONTROL ZONE. HUNTER PLD-AVR (NOT SHOWN) PLD-AVR ALLOWS FOR AIR TO ESCAPE A DRIP IRRIGATION SYSTEM TO PREVENT BLOCKAGE AND WATER HAMMERING. 1/2" MPT CONNECTION WITH 80 PSI MAXIMUM RATING. INSTALL AT THE SUPPLY HEADER AND HIGH POINTS WITHIN A DRIP CONTROL ZONE. AREA TO RECEIVE DRIPLINE HUNTER HDL-09-12-CV HDL-09-12-CV: HUNTER DRIPLINE W/ 0.9 GPH EMITTERS AT 12" O.C. CHECK VALVE, DARK BROWN TUBING W/ BLACK STRIPING. DRIPLINE LATERALS SPACED AT 12" APART, WITH EMITTERS OFFSET FOR TRIANGULAR PATTERN. INSTALL WITH HUNTER PLD BARBED OR PLD-LOC FITTINGS. (NOT SHOWN) HUNTER HQ-33DLRC QUICK COUPLER VALVE, YELLOW LOCKING RUBBER COVER, RED BRASS AND STAINLESS STEEL, WITH 3/4" NPT INLET, 2-PIECE BODY. (NOT SHOWN) MATCO-NORCA 759 BRASS SHUT OFF BALL VALVE, 1/2" TO 4". TWO PIECE BODY, BLOW-OUT PROOF STEM, CHROME PLATED SOLID BRASS BALL, THREADED, WITH PTFE SEATS. SAME SIZE AS MAINLINE PIPE. HUNTER IC-600 MODULAR CONTROLLER, 6 STATIONS, INDOOR MODEL HUNTER WSS WIRELESS SOLAR, RAIN FREEZE SENSOR WITH OUTDOOR INTERFACE, CONNECTS TO HUNTER PCC, PRO-C, AND I-CORE CONTROLLERS, INSTALL AS NOTED. INCLUDES 10 YEAR LITHIUM BATTERY AND RUBBER MODULE COVER, AND GUTTER MOUNT BRACKET. CREATIVE SENSOR TECHNOLOGY FSI-T10-001 1" (25MM) PVC TEE TYPE FLOW SENSOR W/SOCKET ENDS, CUSTOM MOUNTING TEE AND ULTRA-LIGHTWEIGHT IMPELLER ENHANCES LOW FLOW MEASUREMENT. 2 WIRE DIGITAL OUTPUT COMPATIBLE W/ALL IRRIGATION CONTROLLERS. FLOW RANGE: .86-52 GPM. (NOT SHOWN) IRRIGATION MAINLINE: PVC SCHEDULE 40 F A A SS FS IRRIGATION LEGEND NOTE: ITEMS LABELED AS 'NOT SHOWN' SHALL BE INSTALLED AT THE LANDSCAPEDISCRETION AS RECOMMENDED BY THE MANUFACTURER. CONTRACTOR SHALL FOLLOW ALL MANUFACTURER RECOMMENDATIONS IRRIGATION GENERAL NOTES BUCKNER-SUPERIOR 3200 1" 1" NORMALLY CLOSED BRASS MASTER VALVE THAT PROVIDES DIRTY WATER PROTECTION AND NO MINIMUM FLOW FEATURE, WHICH ENSURES RELIABLE OPENING AND CLOSING OF THE VALVE IN EXTREME HIGH OR LOW FLOW SCENARIOS. FEBCO LF825YA 3/4" (CONTRACTOR TO VERIFY SIZING) LEAD FREE REDUCED PRESSURE BACKFLOW PREVENTER. INSTALL BACKFLOW WITHIN A STAINLESS STEEL BACKFLOW ENCLOSURE AVAILABLE FROM V.I.T. STRONG BOX MODEL # SBBC-30SS ON A CONCRETE PAD PER MANUFACTURER`S RECOMMENDATIONS. WATER METER REFER TO CIVIL PLANS MV BF M   HUNTER PROS-PRS30-00-PCN FOR POTS 25360 25 0.25 3' FLOOD BUBBLER, ON FIXED RISER INSTALLED WITHINN POTS. 34