Loading...
HomeMy WebLinkAboutXR2023-2262 - Alternative Material & Methods�CI72U23- ZZte2 CITY OF NEWPORT BE CH RF / COMMUNITY DEVELOPMENT DEPARRR MENT E OF��MM Foe 100 Civic Center Drive BUILDING P.O. Box17768 Newport Beach, CA 92658-8915 GC; <OPMFN Y C,LIfOR��P www.newportbeachca.aov, 1 (949) 644-3200 Off, CASE NO.: t` /� a— 1 1 NFWAh- OF ❑ REQUEST FOR MODIFICATION TO PROVISIONS OF TITLE 9 (FIRE CODE) OR TITLE 15 (BUILDING CODE) OF THE NEWPORT BEACH MUNICIPAL CODE (See Reverse for Basis for Approval) (Fee $306) ® REQUEST FOR ALTERNATE MATERIAL OR METHOD OF CONSTRUCTION (See Reverse for Basis for Approval) (Fee $306) For above requests, complete Sections 1, 2 8 3 below by printing in ink or typing. JOB ADDRESS: III FOR STAFF USE ONLY 11` Plan Check # PC2023-1945 # of Stories 197 i.'i + firlQ Occupancy Classification 'P4 / t/ T— Use of Building SEA #of Units Project Status nMMR OLAnr /MfP_dc Construction Type v - soRovkpn Verified by No. of Items I Fee due �. O DISTRIBUTION: ❑ Owner LgPlanCheck_AU )91 Petitioner Inspector ❑ Fire ❑ Other PETITIONER: SITE ADDRESS: 2808 Ocean Blvd Petitioner Brittany Oakes Owner Carmel Beach 2022 LLC fYeaarner to be anM tw englneed Address 6113 Bristol Parkway, Suite 275 Address 151 Culver City, CA zip 90230 Costaa Mesa, CA us Drive. Ste. zip 92626 Daytime Phone (832) 465.4510 Daytime Phone (714) 754.4040 Email: brittany@brandonarchitects.com 3 USTIFICATION/FINDINGS OF EQUIVALENCY: CODE SECTIONS: Code min. for exterior weep screed heights is impractical for CBC 1808.7.4 , A7e3jr Z Position Project Architect I Petitioners Signature'�C�- CA Professional Lic. # C-40174 Date: 11.30.23 FOR STAFF USE ONLY DEPARTMENT ACTION: In accordance with: IWCBC 104.11/CFC 104.9 ❑ CBC 104.10/CFC 104.8 / JAIternate materials 8. methods) (CBC Modification) ❑ Concurrence from Fire Code Official is required. ❑ Approved ❑ Disapproved ❑ Written Comments Attached By; Date Request (DOE ) ( S_NO .lessen any fre protection requirements. N' i ��(Request (DOE (D ffN6) sen the structural integrity The Request is: Granted ❑ Denied (See reverse for appeal information) ❑ Granted (Ratification required) Conditions of Approval: erPositio�nr-FRNfRfOFFIfIALDate gnatue )z- 7 "ZOG'z3 LIE APPEAL OF DIVISION ACTION TO THE BUILDING BOARD OF APF'EAL)S (�ee C*verse) (Signature, statement of owner or applicant, statement of reasons for appeal and fling fees are required.) CASHIER RECEIPT NUMBER: -I /-- oZ-04Z Io2-3 Forms\modif 08/21/23 MOD WEEP SCREED- PLANS i DATE: 11/30/23 PROJECT: MERZI RESIDENCE ADDRESS: 2808 OCEAN BLVD CORONA DEL MAR, CA 82625 , MOD REQUEST - FIRST LEVEL FLOOR PLAN " - 30'-0" 0 MOD REQUEST - BASEMENT LEVEL FLOOR PLAN " - 30-0" i BRANDON AHCHIiECiS I l+I f.ahml,Ur. BRANDO(Q QCHITE jTS k i � 4 . MOD - WEEP SCREED V/A.lJ-2. O BRANDON ARCHITECTS DATE: 11/30/23 PROJECT: MERZI RESIOFNCE ADDRESS: 2808 OCEAN BLVD CORONA DEL MAR, CA 92625 FLASHING NOTE: REF. MATERIAL SCHEDULE ON A/AA FOR FLASHING NOTES INTERIOR FINISH GYPSUM BOARD PLYWOOD SHT'G. BITUTHENE (OR EQUIV.) - 18" ABV. T.O.S. (CONTINUOUS 24") COPPER/SS FLASHING OVER BITUTHENE (OR EQUIV.) 6" ABV. T.O.S. (CONTINUOUS 12") EXT. FINISH PER PLANS PRESERVATIVE -TREADED WOOD SILL PER AWPA U1 CORROSION -RESISTANCE WEEP SCREED, MIN. 26 GALVANIZED SHEET GAGE WEEP SCREED W/. MIN. 3-1/2" ATTACHMENT FLANGE PER R703.7.2.1 FOR STUCCO FINISH LINE OF FINISH GRADE (AS OCCURS) COPPER/SS FLASHING OVER BITUTHENE (OR EQUIV.) 6" BELOW T.O.S. (CONTINUOUS 12") LINE OF CONCRETE SLAB OR PAVED AREA (AS OCCURS) CONCRETE FOUNDATION NOTE: ALL METAL FLASHING AND WEEP SCREED TO BE OF A SIMILAR TYPE TO AVOID GALVANIC CORROSION C6) WEEP SCREED DR. 3" = I'-0" BRANDON'i/CHITECTS I 15/ l„ihnn, 0, N21111 iI-! ( I In' 11',.r , I "(''n -/+ -.`a. v),P) MOD - WEEP( SCREED -12/AD-2.0 L DATE: 11/30/23 PROJECT: MER71 RESIDENCE ADDRESS: 2808 OCEAN BLVD CORONA DEL MAR, CA 92626 NOTE: 1. ALL METAL FLASHING AND WEEP SCREED TO BE OF A SIMILAR TYPE TO AVOID GALVANIC CORROSION 2. REF. MATERIAL SCHEDULE ON A/A-4.0 FOR FLASHING NOTES 3. WATERPROOFING, DAMPROOFING, AND DRAINAGE TO BE PROVIDED AND INSTALLED PER R405 & R406 BRANDON ARCHITECTS EXTERIOR I INTERIOR PLYWOOD SHTG. PER STRUCT. AND EXT. FINISH MFGR. INTERIOR FINISH PER PLAN, VERIFY W/. I.D. & OWNER BITUTHENE (OR EQUIV.) - MIN. 18" ABV. T.O.C. (MIN. CONTINUOUS 24") AIR -PERMEABLE INSULATION PER PLANS EXT. FINISH PER PLANS I 2" SPRAYED AIR -IMPERMEABLE INSULATION AS a OCCUR PER EXT. WALL DETAIL COPPER/S.S. FLASHING OVER BITUTHENE (OR EQUIV.) MIN. B" ABV. T.O.C. I FLOOR FINISH PER PLAN, VERIFY W/. I.D. & OWNER I CORROSION RESISTANT FLASHING PER R703, MIN. 26 0 1 -1/B" SHTG. PER STRUCT. GAUGE GALVANIZED W/.3-1/2' FLANGE i m_ *—SLOPE PER CIVIL CONNECTION PER STRUCT. CONTINUOUS WATERPROOF MEMBRANE OVER I ^I INTERIOR FINISHES PER PLAN, VERIFY W/. I.E. & OWNE TOP OE BASEMENTWALL AND 24"UP EXTERIOR WALL i BASEMENT CONCRETE WALL PER STRUCT. DRAINAGE MAT PER WATERPROOFI I G MFGR. �BATT INSULATION PER T-24 @ CONDITIONED SPACES 1/2" AIR GAP INTERIOR FINISHES PER PLAN, VERIFY W/. I.D. & OWNE C2BASEMENT WALL WEEP SCREED 1 112" = 1'-0" � I BRANDONAu 'i l I A