HomeMy WebLinkAboutS2020-0157 - MiscSOUTHWEST Insl)Cclion 8, Nesting, Inc. 441 Commercial Way, La Habra, CA 90631-6168 (562)941-2990 (714)526-8441 FAX (562)946-0026 FIELD DATA ON TEST SPECIMENS --- ASTM C31, C138, C143, C172, C173, C231, C1064 --- CONCRETE: X MORTAR: SHOTCRETE: CORES: GUNITE: ADDRESS: 2007 SANTIAGO RD, NEWPORT BCH JOB #: DATE: 12/21/2020 JOB NAME: PERMIT #: ISSUED BY: ARCHITECT: ENGINEER: CONTRACTOR: SUB: LOCATION IN STRUCTURE TRACT: PHASE: LOT #: CONCRETE SUPPLIER: PLANT: MIX #: TYPE OF CEMENT: ADMIXTURE: TICKET #: SLUMP: 0.00 in. WATER ADDED: 0 gal. AIR TEMP: 0 F CONCRETE TEMP: 0 F MIXING TIME: 0 min. TIME CAST: 00:00 DATE CAST: 11/23/2020 RECEIVED AT LAB: 11/25/2020 SPECIMENS MADE BY: THOMAS GEORGE SPECIFIED PSI @ 28 Days: 4500 LAB #: 172870 CLIENT: DEPUTY 1 INSPECTION TESTING INFORMATION: SAMPLE IDENTIFICATION: 2135428 2135429 2135430 AGE DAYS: 28 28 28 DATE TEST: 12/21 /2020 12/21 /2020 12/21 /2020 SIZE (in.): Height X Diameter 8.000 X 4.000 8.000 X 4.000 8.000 X 4.000 AREA (in.A2): 12.57 12.57 12.57 CRUSH LOAD (lbs.): 71415 69874 69211 COMPRESSIVE STRENGTH (psi.): 5680 5560 5510 HEIGHT -DIAMETER RATIO: CORRECTION FACTOR: CORRECTED STRENGTH (psi.): BREAK TYPE: III II IV C.T.M. USED: Forney96 Forney96 Forney96 REMARKS: NO PAPERWORK ASTM C39, C174, C192, C470, C617, C42 COMPLIES: X DOES NOT COMPLY: FOR INFORMATION: THIS REPORT SHALL NOT BE REPRODUCED, EXCEPT IN FULL, WITHOUT THE APPROVAL OF SOUTHWEST INSPECTION AND TESTING, INC. SAMPLES CAST BY OTHERS: NOTICE:These test results are from samples cast by inspectors or technicians not employed by our firm. They were either delivered to our laboratory or picked up by our driver. We will accept no responsibility for the inspection made on the jobsite by the inspector, furthermore we do not take responsibility for any information on this report other than the strength as tested and reported. ASTM C39 BREAKS: I=CONE - II=CONE AND SPLIT - RESPECTFULLY SUBMITTED SOUTHWEST INSPECTION AND TESTING ZAFAR AHM J_)t� PRINCIPAL ENGINEER III=COLUMNAR - IV=SHEAR - V=SIDE FRACTURES - VI=POINTED ACOUSTICAL ENGINEERING ANALYSIS 2007 Santiago Dr. Newport Beach, CA 92660 April 1, 2024 YANCHAR DESIGN & CONSULTING GROUP 26741 Portola Parkway, Suite 1 E, Foothill Ranch, CA 92610 Tel: 949.770.6601 Fax: 949.770.6575 E-mail: info@yanchardesign.com 2007 Santiago Dr. April 1, 2024 1.0 Introduction At the request of Sunbrite Pools, Yanchar Design & Consulting Group has completed field measurements and an acoustical analysis of the pool equipment located at 2007 Santiago Dr., Newport Beach, CA. 2.0 Project Description The property is a single-family residence. The pool equipment is located approximately 11 feet 6 inches from the property line to the west. The nearest property to the west is also a single-family residence. The properties are separated by a 6-foot wood fence. The City of Newport Beach requires a sound test by an acoustical engineer is required to demonstrate that the noise level from the pool or spa pump is less than 55 dBA at the property line. NBMC10.26. 025. YANCHAR DESIGN & CONSULTING GROUP 2 2007 Santiago Dr. April 1, 2024 2.0 Field Measurements Measurements were made at the site on April 1, 2024 to determine the sound level of the pool equipment. The ambient noise level at the property was dominated by aircraft overflights, local traffic and local construction activity. The sound level of the pool equipment measured at the southern property line was 49.7 dBA. Therefore, the equipment is in compliance with the requirements of the City of Newport Beach Municipal Code. A Soft dB Piccolo -II Integrating Sound Level Meter, Serial Number P0219050803 and CEL Instruments Model CEL-284/2 Calibrator, Serial Number 4/09023134, were used for the measurements. Respectfully submitted, Yanchar Design & Consulting Group Carl J. Yanchar President YANCHAR DESIGN & CONSULTING GROUP 3 2007 Santiago Dr. April 1, 2024 F' kle 11 4 d y qp�4 Y 3 � PROJECT VICINITY PROJECT SITE YANCHAR DESIGN & CONSULTING GROUP 4